WorldWideScience

Sample records for chapman valve manufacturing

  1. Results of the radiological survey at the former Chapman Valve Manufacturing Company, Indian Orchard, Massachusetts (CIO001)

    Energy Technology Data Exchange (ETDEWEB)

    Foley, R.D.; Uziel, M.S.

    1992-07-01

    Radiological survey was conducted at Building 23 (Department No. 40) at the former Chapman Valve Manufacturing Company, Indian Orchard, Massachusetts. The survey was performed in August 1991. The purpose of the survey was to determine whether the property was contaminated with radioactive residues, principally {sup 238}U, as a result of work done for the Atomic Energy Commission (AEC) during the 1940s. The survey included a gamma scan, a beta-gamma scan, and measurement of alpha activity; measurement of direct and removable alpha and beta-gamma levels; and the collection of soil, dust, debris, and smear samples for radionuclide analyses. Survey emphasis was on interior floors, walls, and overhead beams. Radionuclide analysis of soil, dust, and debris, and analysis of smear samples indicate that residual {sup 238}U attributable to former AEC-supported operations is present at this site. Elevated levels of radioactivity were particularly evident on the floors and walls in the western part of the central area of the building (grid blocks Al through A6). Concentrations of {sup 238}U in dust samples collected from overhead beams exceeded DOE guidelines in grid blocks Al through A14 and remained elevated in grid blocks A15 through A19. Dust on a movable overhead crane in grid block A23 was well above the guideline, probably because the crane had at some time been located further west. Some contamination was evident in grid blocks B1 through B5, but clutter and debris in this area prevented a thorough survey.

  2. JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement.

    Science.gov (United States)

    Capulli, Andrew K; Emmert, Maximillian Y; Pasqualini, Francesco S; Kehl, Debora; Caliskan, Etem; Lind, Johan U; Sheehy, Sean P; Park, Sung Jin; Ahn, Seungkuk; Weber, Benedikt; Goss, Josue A; Hoerstrup, Simon P; Parker, Kevin Kit

    2017-07-01

    Tissue engineered scaffolds have emerged as a promising solution for heart valve replacement because of their potential for regeneration. However, traditional heart valve tissue engineering has relied on resource-intensive, cell-based manufacturing, which increases cost and hinders clinical translation. To overcome these limitations, in situ tissue engineering approaches aim to develop scaffold materials and manufacturing processes that elicit endogenous tissue remodeling and repair. Yet despite recent advances in synthetic materials manufacturing, there remains a lack of cell-free, automated approaches for rapidly producing biomimetic heart valve scaffolds. Here, we designed a jet spinning process for the rapid and automated fabrication of fibrous heart valve scaffolds. The composition, multiscale architecture, and mechanical properties of the scaffolds were tailored to mimic that of the native leaflet fibrosa and assembled into three dimensional, semilunar valve structures. We demonstrated controlled modulation of these scaffold parameters and show initial biocompatibility and functionality in vitro. Valves were minimally-invasively deployed via transapical access to the pulmonary valve position in an ovine model and shown to be functional for 15 h. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Cobalt asthma in metalworkers from an automotive engine valve manufacturer.

    Science.gov (United States)

    Walters, G I; Robertson, A S; Moore, V C; Burge, P S

    2014-07-01

    Cobalt asthma has previously been described in cobalt production workers, diamond polishers and glassware manufacturers. To describe a case series of occupational asthma (OA) due to cobalt, identified at the Birmingham Heartlands Occupational Lung Disease Unit, West Midlands, UK. Cases of cobalt asthma from a West Midlands' manufacturer of automotive engine valves, diagnosed between 1996 and 2005, were identified from the SHIELD database of OA. Case note data on demographics, employment status, asthma symptoms and diagnostic tests, including spirometry, peak expiratory flow (PEF) measurements, skin prick testing (SPT) and specific inhalational challenge (SIC) tests to cobalt chloride, were gathered, and descriptive statistics used to illustrate the data. The natural history of presentations has been described in detail, as well as a case study of one of the affected workers. Fourteen metalworkers (86% male; mean age 44.9 years) were diagnosed with cobalt asthma between 1996 and 2005. Workers were principally stellite grinders, stellite welders or machine setter-operators. All workers had positive Occupational Asthma SYStem analyses of serial PEF measurements, and sensitization to cobalt chloride was demonstrated in nine workers, by SPT or SIC. We have described a series of 14 workers with cobalt asthma from the automotive manufacturing industry, with objective evidence for sensitization. Health care workers should remain vigilant for cobalt asthma in the automotive manufacturing industry. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Manufacture and application of valve-regulated lead/acid batteries in China

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z. [Battery Consultants China, Univ. of Science and Technology Beijing, Beijing, BJ (China)

    1998-05-18

    This paper introduces the manufacture and application of valve-regulated lead/acid batteries in China. The contents cover the following topics: (i) background development; (ii) materials; (iii) manufacturing technology and equipment; (iv) application and market prospects. (orig.)

  5. Rapid manufacturing techniques for the tissue engineering of human heart valves.

    Science.gov (United States)

    Lueders, Cora; Jastram, Ben; Hetzer, Roland; Schwandt, Hartmut

    2014-10-01

    Three-dimensional (3D) printing technologies have reached a level of quality that justifies considering rapid manufacturing for medical applications. Herein, we introduce a new approach using 3D printing to simplify and improve the fabrication of human heart valve scaffolds by tissue engineering (TE). Custom-made human heart valve scaffolds are to be fabricated on a selective laser-sintering 3D printer for subsequent seeding with vascular cells from human umbilical cords. The scaffolds will be produced from resorbable polymers that must feature a number of specific properties: the structure, i.e. particle granularity and shape, and thermic properties must be feasible for the printing process. They must be suitable for the cell-seeding process and at the same time should be resorbable. They must be applicable for implementation in the human body and flexible enough to support the full functionality of the valve. The research focuses mainly on the search for a suitable scaffold material that allows the implementation of both the printing process to produce the scaffolds and the cell-seeding process, while meeting all of the above requirements. Computer tomographic data from patients were transformed into a 3D data model suitable for the 3D printer. Our current activities involve various aspects of the printing process, material research and the implementation of the cell-seeding process. Different resorbable polymeric materials have been examined and used to fabricate heart valve scaffolds by rapid manufacturing. Human vascular cells attached to the scaffold surface should migrate additionally into the inner structure of the polymeric samples. The ultimate intention of our approach is to establish a heart valve fabrication process based on 3D rapid manufacturing and TE. Based on the computer tomographic data of a patient, a custom-made scaffold for a valve will be produced on a 3D printer and populated preferably by autologous cells. The long-term goal is to support

  6. Preparation and characterization of an acellular bovine pericardium intended for manufacture of valve bioprostheses.

    Science.gov (United States)

    Goissis, Gilberto; Giglioti, Aparecida de Fátima; Braile, Domingo Marcolino

    2011-05-01

    Major problems with biological heart valves post-implantation are associated with progressive structural deterioration and calcification attributed to glutaraldehyde processing, dead cells, and cell fragments present in the native tissue. In spite of these problems, glutaraldehyde still is the reagent of choice. The results with acellular matrix xenograft usually prepared by detergent treatment in association with enzymes are rather conflicting because while preserving mechanical properties, tissue morphology and collagen structure are process dependent. This work describes a chemical approach for the preparation of an acellular bovine pericardium matrix intended for the manufacture of heart valve bioprostheses. Cell removal was performed by an alkaline extraction in the presence of calcium salts for periods ranging from 6 to 48 h. The results showed that cell removal was achieved after 12 h, with swelling and negative charge increasing with processing time. Nevertheless, collagen fibril structure, ability to form fibrils, and stability to collagenase were progressive after 24-h processing. There was no denaturation of the collagen matrix. A process is described for the preparation of acellular bovine pericardium matrices with preserved fibril structure and morphology for the manufacture of cardiac valve bioprostheses and may be used in other applications for tissue reconstruction. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Chapman Conference on Rainfall Fields

    Science.gov (United States)

    Gupta, V. K.

    The Chapman Conference on Rainfall Fields, sponsored by AGU, was the first of its kind; it was devoted to strengthening scientific interaction between the North American and Latin American geophysics communities. It was hosted by Universidad Simon Bolivar and Instituto Internacional de Estudios Avanzados, in Caracas, Venezuela, during March 24-27, 1986. A total of 36 scientists from Latin America, the United States, Canada, and Europe participated. The conference, which was convened by I. Rodriguez-Iturbe (Universidad Simon Bolivar) and V. K. Gupta (University of Mississippi, University), brought together hydrologists, meteorologists, and mathematicians/statisticians in the name of enhancing an interdisciplinary focus on rainfall research.

  8. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mell, Ellen [Aerovalve, LLC, St. Louis, Mo (United States)

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  9. Carrie Chapman Catt and Woman Suffrage.

    Science.gov (United States)

    Hardesty, Carolyn, Ed.

    1989-01-01

    Most of the material for this issue of the "Goldfinch," which explores the life of Carrie Chapman Catt, came from the archives of the State Historical Society of Iowa. Carrie Chapman Catt (1859-1947) was an Iowan who advocated woman suffrage and spent 26 years actively working for that cause. The issue contains a biography of Catt, and…

  10. The scientific legacy of Sydney Chapman

    Science.gov (United States)

    Akasofu, Syun-Ichi

    2011-08-01

    Sydney Chapman (1888-1970) was arguably one of the greatest scientists of the twentieth century. His comprehensive work on the kinetic theory of gases and solar-terrestrial physics, as well as on the mechanisms behind the formation of Earth's ozone layer, has inspired a wide swath of research spanning several generations [Van Allen, 1970]. Chapman, a member of the Royal Society, in London, and president of the International Geophysical Year (IGY), also was a recipient of AGU's William Bowie Medal. Young AGU members today may recognize Chapman from the topical conferences that carry his name. Although his biography has so far not been published, he gave three talks on his life: two at the National Center for Atmospheric Research, Boulder, Colo., in 1965 and 1966, and one at the Geophysical Institute, University of Alaska Fairbanks, in 1967 (see Figure 1). All three are transcribed and included in a book, Sydney Chapman, Eighty: From His Friends [Akasofu et al., 1968]. These talks, combined with other sources, shed light on this insightful and discerning scientist.

  11. Control valve and control valve system for controlling solids flow, methods of manufacture thereof and articles comprising the same

    Energy Technology Data Exchange (ETDEWEB)

    Jukkola, Glen D.; Teigen, Bard C.

    2017-04-11

    Disclosed herein is a solids flow control valve comprising a standpipe; a shoe; and a transport pipe; wherein the standpipe is in operative communication with the shoe and lies upstream of the shoe; the standpipe comprising a first end and a second end, where the first end is in contact with a source that contains disposable solids and the second end is in fluid contact with the shoe; the shoe being operative to restrict the flow of the disposable solids; the transport pipe being disposed downstream of the shoe to receive and transport the solids from the shoe.

  12. Measurement of opening and closing angles of aortic valve prostheses in vivo using dual-source computed tomography: Comparison with those of manufacturers' in 10 different types

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Young Joo; Kim, Young Jin; Hong, Yoo Jin; Lee, Hye Jeong; Hur, Jin; Im, Dong Jin; Kim, Yun Jung; Choi, Byoung Wook [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.

  13. Research on design and manufacturing methods of hydraulic valve blocks%液压集成阀块设计及制造方法研究

    Institute of Scientific and Technical Information of China (English)

    禹阳华; 程度旺; 黄长发

    2012-01-01

    阐述了液压集成阀块的设计要点、油道通径及材料的选择,指出了阀块机加工需注意的问题,举例说明了阀块设计的具体过程,对液压集成阀块的设计与制造具有指导意义.%The paper presents key points of design, and selection of orifice diameter and material of hydraulic valve blocks, as well as specific problems requiring high attention for machining valve blocks. In addition, the paper shows detailed process for design of valve blocks, which gives guidance to design and manufacturing of the hydraulic valve blocks.

  14. Chapman Solar Zenith Angle variations at Titan

    Science.gov (United States)

    Royer, Emilie M.; Ajello, Joseph; Holsclaw, Gregory; West, Robert; Esposito, Larry W.; Bradley, Eric Todd

    2016-10-01

    Solar XUV photons and magnetospheric particles are the two main sources contributing to the airglow in the Titan's upper atmosphere. We are focusing here on the solar XUV photons and how they influence the airglow intensity. The Cassini-UVIS observations analyzed in this study consist each in a partial scan of Titan, while the center of the detector stays approximately at the same location on Titan's disk. We used observations from 2008 to 2012, which allow for a wide range of Solar Zenith Angle (SZA). Spectra from 800 km to 1200 km of altitude have been corrected from the solar spectrum using TIMED/SEE data. We observe that the airglow intensity varies as a function of the SZA and follows a Chapman curve. Three SZA regions are identified: the sunlit region ranging from 0 to 50 degrees. In this region, the intensity of the airglow increases, while the SZA decreases. Between SZA 50 and 100 degrees, the airglow intensity decreases from it maximum to its minimum. In this transition region the upper atmosphere of Titan changes from being totally sunlit to being in the shadow of the moon. For SZA 100 to 180 degrees, we observe a constant airglow intensity close to zero. The behavior of the airglow is also similar to the behavior of the electron density as a function of the SZA as observed by Ågren at al (2009). Both variables exhibit a decrease intensity with increasing SZA. The goal of this study is to understand such correlation. We demonstrate the importance of the solar XUV photons contribution to the Titan airglow and prove that the strongest contribution to the Titan dayglow occurs by solar fluorescence rather than the particle impact that predominates at night.

  15. Generalized Relativistic Chapman-Enskog Solution of the Boltzmann Equation

    CERN Document Server

    García-Perciante, A L; García-Colin, L S

    2007-01-01

    The Chapman-Enskog method of solution of the relativistic Boltzmann equation is generalized in order to admit a time-derivative term associated to the thermodynamic force in its first order solution. Both existence and uniqueness of such a solution are proved based on the standard theory of integral equations. The mathematical implications of the generalization here introduced are briefly explored.

  16. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  17. Chapman-Jouguet deflagrations and their transition to detonation

    CERN Document Server

    Saif, Mohamed; Pekalski, Andrzej; Levin, Marc; Radulescu, Matei I

    2015-01-01

    We study experimentally fast flames and their transition to detonation in mixtures of methane, ethane, ethylene, acetylene, and propane mixtures with oxygen. Following the interaction of a detonation wave with a column of cylinders of varying blockage ratio, the experiments demonstrate that the fast flames established are Chapman-Jouguet deflagrations, in excellent agreement with the self-similar model of Radulescu et al. (2015). The experiments indicate that these Chapman-Jouguet deflagrations dynamically restructure and amplify into fewer stronger modes until the eventual transition to detonation. The transition length to a self-sustained detonation was found to correlate very well with the mixtures' sensitivity to temperature fluctuations, reflected by the $\\chi$ parameter introduced by Radulescu, which is the product of the non-dimensional activation energy $E_a/RT$ and the ratio of chemical induction to reaction time $t_i/t_r$. Correlation of the measured DDT lengths determined that the relevant characte...

  18. Valve Disease

    Science.gov (United States)

    ... heart valves, valve insufficiency, valve regurgitation, valve stenosis, valvular heart disease Every time your heart beats, blood flows into, ... removed from the market after being linked to heart valve disease. An infection in the lining of the heart's ...

  19. PWR safety and relief valve test program. Valve selection/juftification report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-12-01

    NUREG 0578 required that full-scale testing be performed on pressurizer safety valves and relief valves representative of those in use or planned for use in PWR plants. To obtain valve performance data for the entire population of PWR plant valves, nine safety valves and ten relief valves were selected as a fully representative set of test valves. Justification that the selected valves represent all PWR plant valves was provided by each safety and relief valve manufacturer. Both the valve selection and justification work was performed as part of the PWR Safety and Relief Valve Test Program conducted by EPRI on behalf of the PWR utilities in response to the recommendations of NUREG 0578 and the requirements of the NRC. Results of the Safety and Relief Valve Selection and Justification effort is documented in this report.

  20. Fundamentals of Seismic Wave Propagation by Chris Chapman

    Science.gov (United States)

    Aster, Richard

    2005-03-01

    The analytic characterization and modeling of seismic wave propagation using ray theory based formulations is a core aspect of seismology with a distinguished and very important history. Fundamentals of Seismic Wave Propagation, by Chris Chapman, provides a mathematically rigorous and substantially complete summary of theory and techniques, with exercises, written at an accessible level for intermediate-to-advanced seismology graduate students and for the general research community. I was particularly pleased to see that much relevant mathematics is well summarized in a valuable ``preliminaries'' section containing mathematical and physics background material, coupled with four focused mathematical Appendices covering relevant integrals, Fourier transforms, ordinary differential equations, and saddle-point methods. This bodes well for the text as a teaching resource.

  1. Chapman Conference on Sediment Transport Processes in Estuaries

    Science.gov (United States)

    Perillo, Gerardo M. E.; Lavelle, J. William

    During the week of June 13-17, 1988, 72 sediment transport researchers “aggregated” at the Universidad Nacional del Sur in Bahfa Blanca, Argentina, to participate in an AGU Chapman Conference on Sediment Transport Processes in Estuaries. The main goals of the meeting were to discuss recent advances in estuarine science, to appraise promising future research directions, and to develop contacts and establish working relationships between Latin American and non-Latin- American estuarine researchers. The meeting drew participants from Argentina, Brazil, Chile, Uruguay, Venezuela, the U.S., Canada, Britain, France, the Federal Republic of Germany, The Netherlands, and South Africa. Meeting cosponsors were UNESCO, Secretaria de Ciencía y Técnica, Consejo Nacional de Investigaciones Cientificas y Técnicas, Comision de Investigaciones Cientificas de la Provincia de Buenos Aires, Universidad del Sur, Municipalidad de Bahia Blanca, Asociaciôn Argentina de Geofisicos y Geodestas (AGU sister organization), and the Instituto Argentino de Oceanografia (IADO).

  2. Chapman Conference on Generation of the Oceanic Lithosphere

    Science.gov (United States)

    Presnall, D. C.; Hales, A. L.; Frey, F. A.

    On April 6-10, 1981, the Chapman conference on Generation of the Oceanic Lithosphere was held at Airlie House, Warrenton, Virginia. It was convened by D.C. Presnall, A.L. Hales (both at the University of Texas at Dallas), and F.A. Frey (Massachusetts Institute of Technology). The purpose of the conference was to bring together scientists with diverse specialties to develop a better understanding of the constraints imposed by geophysics, geochemistry, petrology, and tectonics on processes of oceanic lithosphere generation. Sessions were held on the nature of the crust and upper mantle at spreading centers; trace elements and isotopes; experimental petrology; magma chamber dynamics, melt migration, and mantle flow; slow versus fast spreading ridges; Atlantic spreading centers; Pacific spreading centers; and hydrothermal activity, metasomatism, and metamorphism. Fifty-four oral papers and 47 poster papers were presented. One hundred twenty-eight scientists attended from Australia, Canada, Cyprus, Denmark, France, Iceland, Japan, Mexico, United Kingdom, United States, and the USSR.

  3. Kinetic theory the Chapman-Enskog solution of the transport equation for moderately dense gases

    CERN Document Server

    Brush, S G

    1972-01-01

    Kinetic Theory, Volume 3: The Chapman-Enskog Solution of the Transport Equation for Moderately Dense Gases describes the Chapman-Enskog solution of the transport equation for moderately dense gases. Topics covered range from the propagation of sound in monatomic gases to the kinetic theory of simple and composite monatomic gases and generalizations of the theory to higher densities. The application of kinetic theory to the determination of intermolecular forces is also discussed. This volume is divided into two sections and begins with an introduction to the work of Hilbert, Chapman, and Ensko

  4. Testing of Usually Used Valves Manufactured by API Standards of Piping Works for Watersupply and Drainage in Petrochemical Industry%石油化工给排水管道常用API标准制造阀门的试验

    Institute of Scientific and Technical Information of China (English)

    成义祥

    2014-01-01

    该文介绍了石油化工给排水管道常用API标准制造阀门—闸阀、截止阀、蝶阀的试验项目及试验比例,通过在某大型石油化工项目的成功实践,证明了严格执行该阀门试验项目及试验比例对保证石油化工给排水管道施工质量的必要性、合理性。%Testing items and proportion of Usually Used Valves namely gate valve,globe valve, butterfly valve manufactured by API standards of piping worksfor watersupply and drainage in petrochemical industry is introduced. It is proved that strictly performing the testing items and proportion is essential and reasonable to ensure construction quality of piping works for watersupply and drainage in petr- ochemical industry through practicing in some large petrochemical project.

  5. Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard.

    Science.gov (United States)

    Woerdeman, Peter A; Cochrane, David D

    2014-05-01

    Authors of this report describe 2 patients who had undergone shunt insertion for hydrocephalus and who, at 6 weeks or 9 months after their last revision, presented with symptoms of shunt dysfunction and CSF collections at the valve site. At the ensuing shunt revision in both patients, the silicone housing was fractured and the Siphonguard was disconnected from the Codman Hakim Precision flat-bottom valve. The cause of these failures was not clear since manipulation, bending, and twisting of the valves were not thought to have occurred during implantation. A review of the FDA's Manufacturer and User Facility Device Experience (MAUDE) database revealed 58 cases of silicone housing failure in the Codman Hakim Precision valve with integrated Siphonguard since the year 2000. A single report was found in the databases administered by the Canadian Medical Devices Sentinel Network (CMDSNet). The Codman Hakim Precision valves with integrated Siphonguard are delicate devices that do not withstand the intraoperative handling tolerated by other valves. When these valves are implanted, gentle handling and wide exposures are needed to minimize the risk of valve damage. Valves should be handled according to the manufacturer's instructions. However, in light of this particular pattern of failure, it is recommended that the manufacturer redesign this valve to provide handling tolerance that is characteristic of other valves on the market. The featured cases illustrate the importance of the surgeon's role in postmarket surveillance of medical devices and reporting device failures to the responsible agencies and manufacturers.

  6. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  7. The AGU Chapman Conference on Communicating Climate Science: A Historic Look to the Future

    Science.gov (United States)

    Byrne, J. M.; Rasch, P. J.; Andronova, N. G.

    2013-12-01

    The American Geophysical Union hosted a Chapman Conference on Communicating Climate Science at Snow Mountain Ranch, Granby, Colorado, June 8-13, 2013. The goal of the Chapman Conference was to bring together scholars, social scientists and journalists to discuss the history, and more importantly, the present and future of climate change communication. We met to evaluate our current and needed communication capacity, and to develop ways and means to convey advances in the understanding of climate science. Delegates discussed and presented methods and capacity to communicate to policymakers, the media, and society. Our focus was on the efficacy of scientific communication, on improving communication practices, and on building collaborations spawned at the conference, and beyond. The Chapman was a success. Close to 150 of us gathered high in the Colorado Rockies to share almost 100 presentations and nearly 10 hours of group discussions focused on ways and means to better bring the climate change message to society, to educators and policymakers in North America and around the world. This presentation will focus on the outcomes of the Chapman Climate Change Communication Conference; the conclusions of the delegate community; and directions forward.

  8. Chapman, A. . Camels, diamonds and counterfactuals : a model for teaching causal reasoning

    NARCIS (Netherlands)

    Weijs, Marijke

    2011-01-01

    In het artikel ‘Camels, diamonds and counterfactuals: a model for teaching causal reasoning’ beschrijft Chapman een onderwijsmodel voor vooruitgang in oorzakelijk redeneren. Dit model is bedoeld voor 16+-leerlingen die met dit model worden toegerust om een robuuste oorzakelijke analyse te maken. Cha

  9. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  10. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  11. Valve's Way

    Directory of Open Access Journals (Sweden)

    Phanish Puranam

    2015-06-01

    Full Text Available What can we learn from outliers? While statisticians rightly warn us against their non-representativeness, we believe it is also true that thinking carefully about what makes them atypical may improve our understanding of the typical case. This is the premise behind the Organization Zoo series. Valve Corporation (Valve is an unusual firm. It is a rare example of a firm that appears to operate without any formal hierarchy in its organization. What can we learn about the viability of authority hierarchies from Valve’s way of organizing? We wrote a brief account of Valve based on public information sources and asked several renowned organizational experts to comment on this unusual firm. We asked them to write a short commentary on what the Valve example means for organizational theorists and practitioners. Thankfully, they all accepted, and we are excited to present the results of their thinking in this first “exhibit” in the Organization Zoo.

  12. Transport properties of multicomponent thermal plasmas: Grad method versus Chapman-Enskog method

    Energy Technology Data Exchange (ETDEWEB)

    Porytsky, P. [Institute for Nuclear Research, 03680 Kyiv (Ukraine); Krivtsun, I.; Demchenko, V. [Paton Welding Institute, 03680 Kyiv (Ukraine); Reisgen, U.; Mokrov, O.; Zabirov, A. [RWTH Aachen University, ISF-Welding and Joining Institute, 52062 Aachen (Germany); Gorchakov, S.; Timofeev, A.; Uhrlandt, D. [Leibniz Institute for Plasma Science and Technology (INP Greifswald), 17489 Greifswald (Germany)

    2013-02-15

    Transport properties (thermal conductivity, viscosity, and electrical conductivity) for multicomponent Ar-Fe thermal plasmas at atmospheric pressure have been determined by means of two different methods. The transport coefficients set based on Grad's method is compared with the data obtained when using the Chapman-Enskog's method. Results from both applied methods are in good agreement. It is shown that the Grad method is suitable for the determination of transport properties of the thermal plasmas.

  13. The deep search of knowledge: George Chapman's glosses in The Shadow of Night (1594

    Directory of Open Access Journals (Sweden)

    Lavinia Silvares

    2017-07-01

    Full Text Available This paper addresses the glosses of the first edition of George Chapman's philosophical elegy, The Shadow of Night (1594, as a specific and common practice of prescriptive work, produced by Renaissance authors following the ancient tradition of the auctoris interpretatio. Assuming the gloss as an exposition and scrutiny of the places of poetic invention and elocution, Chapman puts himself in the position of both annotator and authorizer of his text, defining a particular legibility for the poem within the learned circles of the English court of Shakespeare’s time. Considering the view of the glossarial practice as an emulation of the ancient scholium work of ‘exposing the difficulties’ of a literary text and thus legitimizing it as fit to enter the proper tradition, this paper discusses, 1. the implications of Chapman's glosses for the poem's immediate reception; 2. the importance of authorized role models (Servius, Macrobius, Cornutus for the glossarial practice; and 3. the idea that a text does not possess a congenital clearness of its own, but can only be understood through the continuous process of a specific glossarial assessment.

  14. An analysis of check valve performance characteristics based on valve design

    Energy Technology Data Exchange (ETDEWEB)

    McElhaney, K.L. [Oak Ridge National Lab., TN (United States). Engineering Technology Div.

    2000-04-01

    Although it had been theorized by nuclear industry valve experts that the two most significant factors in assessing check valve performance were valve type (or design) and operating conditions, until recently, no data was available to support their assumptions. In co-operation with the Nuclear Industry Check Valve Group (NIC), Oak Ridge National Laboratory (ORNL) undertook a review and analysis of check valve failures recorded in the Institute of Nuclear Power Operations' (INPO) Nuclear Plant Reliability Data System (NPRDS). This study involved the characterization of failures according to several parameters, including valve design (e.g. swing check, lift check). Since the valve design is not inherently included within the NPRDS engineering record for each component in the database, ORNL relied on input from NIC, valve manufacturers and catalogs to supply the missing information. As a result, nearly 60% of the 21000 check valves listed in the NPRDS component database and 85% of the 838 failures occurring during 1991-1992 were identified according to valve design. This data provided the basis to perform previously unavailable cross-correlations between parameters such as valve design versus failure mode, valve design versus failure discovery method, population/failure distributions by valve design, etc. Performance assessments and predictions based on more specific sets of parameters (as opposed to generic check valve failure rates obtained from standard reference sources that generally ignore the valve design) should result in a significant impact on future nuclear plant operations, including inservice testing (IST) practices, maintenance, and probabilistic risk assessments (PRAs) by providing a means to calculate more appropriate relative (and ultimately absolute) failure rates for check valves. (orig.)

  15. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  16. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  17. Excess flow shutoff valve

    Energy Technology Data Exchange (ETDEWEB)

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  18. AGU Chapman Conference Hydrogeologic Processes: Building and Testing Atomistic- to Basin-Scale Models

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, B. [American Geophysical Union, Washington, DC (United States)

    1994-12-31

    This report presents details of the Chapman Conference given on June 6--9, 1994 in Lincoln, New Hampshire. This conference covered the scale of processes involved in coupled hydrogeologic mass transport and a concept of modeling and testing from the atomistic- to the basin- scale. Other topics include; the testing of fundamental atomic level parameterizations in the laboratory and field studies of fluid flow and mass transport and the next generation of hydrogeologic models. Individual papers from this conference are processed separately for the database.

  19. Evolution of statistical averages: An interdisciplinary proposal using the Chapman-Enskog method

    Science.gov (United States)

    Mariscal-Sanchez, A.; Sandoval-Villalbazo, A.

    2017-08-01

    This work examines the idea of applying the Chapman-Enskog (CE) method for approximating the solution of the Boltzmann equation beyond the realm of physics, using an information theory approach. Equations describing the evolution of averages and their fluctuations in a generalized phase space are established up to first-order in the Knudsen parameter which is defined as the ratio of the time between interactions (mean free time) and a characteristic macroscopic time. Although the general equations here obtained may be applied in a wide range of disciplines, in this paper, only a particular case related to the evolution of averages in speculative markets is examined.

  20. Grid-point requirements for large eddy simulation: Chapman's estimates revisited

    Science.gov (United States)

    Choi, Haecheon; Moin, Parviz

    2012-01-01

    Resolution requirements for large eddy simulation (LES), estimated by Chapman [AIAA J. 17, 1293 (1979)], are modified using accurate formulae for high Reynolds number boundary layer flow. The new estimates indicate that the number of grid points (N) required for wall-modeled LES is proportional to ReLx , but a wall-resolving LES requires N ˜ReLx 13 /7 , where Lx is the flat-plate length in the streamwise direction. On the other hand, direct numerical simulation, resolving the Kolmogorov length scale, requires N ˜ReLx 37 /14 .

  1. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  2. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  3. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    Puranam and Håkonsson (2015) challenge us to ponder what we as organization design theorists make of Valve’s way (see also Jeppesen, 2008). We believe that Valve, in spite of its radical vision, does not represent a challenge to fundamental organization design theory and that it is questionable...

  4. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  5. Robotic mitral valve replacement.

    Science.gov (United States)

    Senay, Sahin; Gullu, Ahmet Umit; Kocyigit, Muharrem; Degirmencioglu, Aleks; Karabulut, Hasan; Alhan, Cem

    2014-01-01

    Robotic surgical techniques allow surgeons to perform mitral valve surgery. This procedure has gained acceptance, particularly for mitral valve repair in degenerative mitral disease. However, mitral repair may not always be possible, especially in severely calcified mitral valve of rheumatic origin. This study demonstrates the basic concepts and technique of robotic mitral valve replacement for valve pathologies that are not suitable for repair.

  6. Titanium in Engine Valve Systems

    Science.gov (United States)

    Allison, J. E.; Sherman, A. M.; Bapna, M. R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a twoto-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance. When properly manufactured, titanium valves have been shown to withstand very stringent durability testing, indicating the technical feasibility of this approach to fuel economy improvement.

  7. Automatic shutoff valve

    Science.gov (United States)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  8. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  9. Adjustable safety relief valve

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, W.L.

    1990-06-12

    This patent describes a pressure relief valve having a relief set pressure. It comprises: a valve body having a fluid inlet and outlet, a spherical, metal valve seat associated with the inlet and a valve member comprising at least a portion of a spherical,metal ball attached to a ball holding element, the valve member being biased against the valve seat and thus providing a metal-to-metal seal preventing the passage of fluids past the valve seat when the fluid pressure in the inlet is below the relief pressure setting of the valve.

  10. Grid-point requirement for large eddy simulation: Chapman's estimation revisited

    Science.gov (United States)

    Choi, Haecheon; Moin, Parviz

    2011-11-01

    Resolution requirements for large eddy simulation (LES), estimated by Chapman [AIAA J. Vol. 17, p. 1293 (1979)], are modified using accurate formulae for high Reynolds number boundary layer flow. This correction indicates that the number of grid points (N) required for wall-modeled LES is proportional to ReL2 / 7 , but a wall-resolving LES requires N ~ReL13 / 7 , where L is the flat-plate length in the streamwise direction. The number of grid points required for the flow over an aircraft using LES with and without modeling the viscous wall region is estimated: the number of grid points for the wall-modeled LES is one to three orders of magnitude smaller than that for the wall-resolving LES, indicating the practical importance of wall modeling in LES for high Reynolds number flows. This work is conducted while HC takes a sabbatical year at Stanford University.

  11. Mutual diffusion coefficient models for polymer-solvent systems based on the Chapman-Enskog theory

    Directory of Open Access Journals (Sweden)

    R. A. Reis

    2004-12-01

    Full Text Available There are numerous examples of the importance of small molecule migration in polymeric materials, such as in drying polymeric packing, controlled drug delivery, formation of films, and membrane separation, etc. The Chapman-Enskog kinetic theory of hard-sphere fluids with the Weeks-Chandler-Andersen effective hard-sphere diameter (Enskog-WCA has been the most fruitful in diffusion studies of simple fluids and mixtures. In this work, the ability of the Enskog-WCA model to describe the temperature and concentration dependence of the mutual diffusion coefficient, D, for a polystyrene-toluene system was evaluated. Using experimental diffusion data, two polymer model approaches and three mixing rules for the effective hard-sphere diameter were tested. Some procedures tested resulted in models that are capable of correlating the experimental data with the refereed system well for a solvent mass fraction greater than 0.3.

  12. Determination of the Chapman- Jouguet Pressure of a High Explosive from One Single Test

    Directory of Open Access Journals (Sweden)

    Manfred Held

    1987-01-01

    Full Text Available Instead of evaluating the data of the surface velocities of adjacent metal foils of different thicknesses with reference to the high explosive charge, the shock wave velocity in a plexiglass block from one firing for one charge type was measured as a function of distance. If the high explosive charge is large enough, for example 64 mm diameter and 100 mm long, then the shock wave induced in the plexiglass gives, over the first 15 mm, a shock velocity which correlates with the detonation pressure or Chapman-Jouguet pressure. With the resolution inherent in this technique, an enhanced velocity over the first few millimeters, which would correspond to a von Neumann spike, could not be detected.

  13. Chapman-Enskog expansion for the Vicsek model of self-propelled particles

    CERN Document Server

    Ihle, Thomas

    2016-01-01

    Using the standard Vicsek model, I show how the macroscopic transport equations can be systematically derived from microscopic collision rules. The approach starts with the exact evolution equation for the N-particle probability distribution, and after making the mean-field assumption of Molecular Chaos leads to a multi-particle Enskog-type equation. This equation is treated by a non-standard Chapman-Enskog expansion to extract the macroscopic behavior. The expansion includes terms up to third order in a formal expansion parameter $\\epsilon$, and involves a fast time scale. A self-consistent closure of the moment equations is presented that leads to a continuity equation for the particle density and a Navier-Stokes-like equation for the momentum density. Expressions for all transport coefficients in these macroscopic equations are given explicitly in terms of microscopic parameters of the model. The transport coefficients depend on specific angular integrals which are evaluated asymptotically in the limit of ...

  14. A linear scale height Chapman model supported by GNSS occultation measurements

    Science.gov (United States)

    Olivares-Pulido, G.; Hernández-Pajares, M.; Aragón-Àngel, A.; Garcia-Rigo, A.

    2016-08-01

    Global Navigation Satellite Systems (GNSS) radio occultations allow the vertical sounding of the Earth's atmosphere, in particular, the ionosphere. The physical observables estimated with this technique permit to test theoretical models of the electron density such as, for example, the Chapman and the Vary-Chap models. The former is characterized by a constant scale height, whereas the latter considers a more general function of the scale height with respect to height. We propose to investigate the feasibility of the Vary-Chap model where the scale height varies linearly with respect to height. In order to test this hypothesis, the scale height data provided by radio occultations from a receiver on board a low Earth orbit (LEO) satellite, obtained by iterating with a local Chapman model at every point of the topside F2 layer provided by the GNSS satellite occultation, are fitted to height data by means of a linear least squares fit (LLS). Results, based on FORMOSAT-3/COSMIC GPS occultation data inverted by means of the Improved Abel transform inversion technique (which takes into account the horizontal electron content gradients) show that the scale height presents a more clear linear trend above the F2 layer peak height, hm, which is in good agreement with the expected linear temperature dependence. Moreover, the parameters of the linear fit obtained during four representative days for all seasons, depend significantly on local time and latitude, strongly suggesting that this approach can significantly contribute to build realistic models of the electron density directly derived from GNSS occultation data.

  15. Refuge alternatives relief valve testing and design.

    Science.gov (United States)

    Lutz, T J; Bissert, P T; Homce, G T; Yonkey, J A

    2016-10-01

    The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as specified by the manufacturer, above mine atmospheric pressure in the RA. To facilitate PRV testing, an instrumented benchtop test fixture was developed using an off-the-shelf centrifugal blower and ductwork. Relief pressures and flow characteristics were measured for three units: (1) a modified polyvinyl chloride check valve, (2) an off-the-shelf brass/cast-iron butterfly check valve and (3) a commercially available valve that was designed specifically for one manufacturer's steel prefabricated RAs and had been adapted for use in one mine operator's built-in-place RA. PRVs used in tent-style RAs were not investigated. The units were tested with different modifications and configurations in order to check compliance with Title 30 Code of Federal Regulations, or 30 CFR, regulations. The commercially available relief valve did not meet the 30 CFR relief pressure specification but may meet the manufacturer's specification. Alternative valve designs were modified to meet the 30 CFR relief pressure specification, but all valve designs will need further design research to examine survivability in the event of a 103 kPa (15.0 psi) impulse overpressure during a disaster.

  16. Language Disorders from a Developmental Perspective: Essays in Honor of Robin S. Chapman. New Directions in Communication Disorders Research

    Science.gov (United States)

    Paul, Rhea, Ed.

    2006-01-01

    The last 25 years have witnessed an explosion of research at the intersection of typical language development and child language disorders. A pioneer in bringing these fields of study together is Robin S. Chapman, Emerita, University of Wisconsin. This contributed volume honors her with chapters written by former students and colleagues, who track…

  17. Valve-in-valve-in-valve: Treating endocarditis of a transcatheter heart valve.

    Science.gov (United States)

    Nguyen, Caroline; Cheong, Adrian P; Himbert, Dominique

    2015-10-01

    Transcatheter heart valve endocarditis is a rare, but life threatening complication. We describe the case of a patient who was successfully treated by transcatheter aortic valve-in-valve-in-valve replacement with a favorable 1-year outcome, despite severe early complications.

  18. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  19. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  20. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  1. Valve-in-Valve Replacement Using a Sutureless Aortic Valve

    Science.gov (United States)

    Dohmen, Pascal M.; Lehmkuhl, Lukas; Borger, Michael A.; Misfeld, Martin; Mohr, Friedrich W.

    2016-01-01

    Patient: Female, 61 Final Diagnosis: Tissue degeneration Symptoms: Dyspnea Medication: — Clinical Procedure: Redo valve replacement Specialty: Surgery Objective: Rare disease Background: We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. Case Report: The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biopros-thesis. The postoperative course was uneventful and the patient was discharged on day 6. Conclusions: The current case report demonstrates that sutureless bioprostheses are an attractive option for surgical valve-in-valve procedures, which can reduce morbidity and mortality. PMID:27694795

  2. Experimental study for flow characteristics and performance evaluation of butterfly valves

    Science.gov (United States)

    Kim, C. K.; Yoon, J. Y.; Shin, M. S.

    2010-08-01

    The industrial butterfly valves have been applied to transport a large of fluid with various fields of industry. Also, these are mainly used a control of fluid flux to the water and waste-water pipeline. Present, butterfly valves are manufacturing for multiplicity shape of bodies and discs with many producers. However, appropriate performance evaluation was not yet accomplished to compare about these valves through experiments. This study is performed the experiment of flow characteristics and performance of manufactured 400A butterfly valves for the water and waste pipeline, and compared experimental results. We performed experiments that were controlled fixed a differential pressure condition (1 psi) and the range of the flow rate conditions (500 m3/hr ~ 2500 m3/hr), and also opened the disc of valves to a range of angle from 9 degree to 90 degree. We investigated and compared the valve flow coefficient and the valve loss coefficient of results through experiments with each butterfly valve.

  3. Modelos de dupla camada difusa de Gouy-Chapman e Stern aplicados a latossolos ácricos paulistas Gouy-chapman and Stern diffuse double layer models applied to acric oxisols from the state São Paulo - Brazil

    Directory of Open Access Journals (Sweden)

    L.R.F. Alleoni

    1994-08-01

    Full Text Available Modelos teóricos da dupla camada difusa de Gouy-Chapman e de Stern foram aplicados a um latossolo variação Una ácrico, de Guaira e a dois latossolos roxos ácricos, localizados em Ribeirão Preto e Guaíra, cidades ao norte do Estado de São Paulo, onde solos com caráter ácrico ocupam vasta área nas quais são cultivadas várias culturas de interesse econômico. Na concentração mais elevada do eletrólito suporte (KCl 0,1N, os dados obtidos em laboratório adaptaram-se melhor ao modelo de Stern. Entretanto, nas menores concentrações (KCl 0,01 e 0,001N, correspondentes a valores mais comuns encontrados em solos altamente intemperizados, o modelo de Gouy-Chapman representou melhor a variação da densidade superficial de carga com o potencial elétrico das amostras estudadas.Theoretical models of Gouy-Chapman and Stern, referred to diffuse double layer, were applied to three acric Oxisols, two named dusky red latosol and one Una variant latosol, from the São Paulo State - Brazil. Samples were collected in Ribeirão Preto and Guaira, regions of large occurrence of these soils, supporting many economic crops. In the highest concentration of the electrolyte (KC1 0.1N, the obtained values were better related to the Stern model. On the other hand, in more dilluted solutions (KC1 0.01 and 0.001N, corresponding to more usual ionic strenght of highly weathered soils, the variation of surface charge density of the samples with electric potential was in better agreement with the Gouy-Chapman theory.

  4. Different stages of flame acceleration from slow burning to Chapman-Jouguet deflagration.

    Science.gov (United States)

    Valiev, Damir M; Bychkov, Vitaly; Akkerman, V'yacheslav; Eriksson, Lars-Erik

    2009-09-01

    Numerical simulations of spontaneous flame acceleration are performed within the problem of flame transition to detonation in two-dimensional channels. The acceleration is studied in the extremely wide range of flame front velocity changing by 3 orders of magnitude during the process. Flame accelerates from realistically small initial velocity (with Mach number about 10(-3)) to supersonic speed in the reference frame of the tube walls. It is shown that flame acceleration undergoes three distinctive stages: (1) initial exponential acceleration in the quasi-isobaric regime, (2) almost linear increase in the flame speed to supersonic values, and (3) saturation to a stationary high-speed deflagration velocity. The saturation velocity of deflagration may be correlated with the Chapman-Jouguet deflagration speed. The acceleration develops according to the Shelkin mechanism. Results on the exponential flame acceleration agree well with previous theoretical and numerical studies. The saturation velocity is in line with previous experimental results. Transition of flame acceleration regime from the exponential to the linear one, and then to the constant velocity, happens because of gas compression both ahead and behind the flame front.

  5. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  6. Aortic Valve Regurgitation

    Science.gov (United States)

    ... inside your heart that involves heart valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a ... the United States — can damage the aortic valve. Rheumatic fever is still prevalent in developing countries but rare ...

  7. Pulmonary Valve Stenosis

    Science.gov (United States)

    ... growths called carcinoid tumors in the digestive system. Rheumatic fever. This complication of an infection caused by streptococcus ... valve stenosis later in life, including: Carcinoid syndrome Rheumatic fever Noonan's syndrome Mild to moderate pulmonary valve stenosis ...

  8. Aortic Valve Disease

    Science.gov (United States)

    ... Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that are ... Transplantation End-stage Lung Disease Adult Lung Transplantation Pediatric Lung ... Aortic Aneurysm Aortic Valve Disease Overview The human heart has ...

  9. Mitral Valve Stenosis

    Science.gov (United States)

    ... up around the ring around the mitral valve (annulus), which can occasionally cause mitral valve stenosis. Other ... the condition of your lungs. Transesophageal echocardiogram. A small transducer attached to the end of a tube ...

  10. Heart valve surgery

    Science.gov (United States)

    ... Tricuspid valve stenosis Risks The risks of having cardiac surgery include: Death Heart attack Heart failure Bleeding requiring ... and the A.D.A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Latest ...

  11. WATER TEMPERATURE and other data from NOAA Ship CHAPMAN in the Gulf of Mexico from 1986-02-03 to 1986-02-19 (NCEI Accession 8600065)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Bathythermograph and Ocean Station data collected from NOAA Ship CHAPMAN. The data was collected from Gulf of Mexico from February 3-19, 1986. The data was...

  12. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  13. Aerodynamic Shutoff Valve

    Science.gov (United States)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  14. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  15. Dump valve assembly

    Science.gov (United States)

    Owen, T.J.

    1984-01-01

    A dump valve assembly comprising a body having a bore defined by a tapered wall and a truncated spherical valve member adapted to seat along a spherical surface portion thereof against said tapered wall. Means are provided for pivoting said valve member between a closed position engagable with said tapered wall and an open position disengaged therefrom.

  16. Quadricuspid Aortic Valve

    Directory of Open Access Journals (Sweden)

    Mehmet Taşar

    2013-03-01

    Full Text Available Quadricuspid aortic valve is an extremely rare congenital defect. Isolated form appears frequently. It is seen with aortic valve regurgitation in adulthood. This case report presents a rare clinical finding of an isolated quadricuspid aortic valve with aortic regurgitation in an 64-year-old female who was referred for cardiac evaluation due to newly identified murmur.

  17. Hard hardfacing by welding in the manufacture of valves; Problem Cobalt, alternatives, advantages, disadvantages; Recargues Duros por Soldadura en la Fabricacion de Valvulas ; el Problema del Cobalto, alternativas, ventajas, inconvenientes

    Energy Technology Data Exchange (ETDEWEB)

    Piquer Caballero, J.

    2014-07-01

    Alloys of recharge usually used in the field of the valves are base alloys cobalt (stellite), but in the field of nuclear power plants, due to radioactive activation of the cobalt, there is a growing trend to replace these alloys with other calls cobalt free . In this paper we will explore the most frequent and will be deducted the relevant advantages and disadvantages of these, in comparison with base alloys cobalt. (Author)

  18. Experimental Validation of Mathematical Framework for Fast Switching Valves used in Digital Hydraulic Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Roemer, Daniel Beck; Bech, Michael Møller;

    2015-01-01

    A prototype of a fast switching valve designed for a digital hydraulic transmission has been manufactured and experimentally tested. The valve is an annular seat valve composed of a plunger connected with a direct electromagnetic moving coil actuator as the force producing element. Based...... on an elaborate optimization method the valve is designed to maximize the efficiency of a digital hydraulic motor targeted to a wind turbine transmission system. The optimisation method comprises a mathematical framework which predicts a valve switching time of approximately 1 ms with a peak actuator input power...

  19. Valve selection in aortic valve endocarditis

    Science.gov (United States)

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis.

  20. Flow Characterization of a Piezo-Electric High Speed Valve

    Directory of Open Access Journals (Sweden)

    T. Takiya

    2012-03-01

    Full Text Available Injecting a gas into fusion reactors or semiconductor manufacturing systems, one has to quickly control the flow rate by a piezoelectric valve. In order to construct a gas injection system with high speed valves in the future, performance tests have been conducted on a commercial piezoelectric valve. An orifice flowmeter for measuring time average flowrate and a hot wire anemometer for instantaneous flowrate were manufactured. The total flow coefficient of the orifice flowmeter was obtained experimentally under a low pressure of a 10-2 Pa and a low flowrate of a few mg/s, although they are smaller than the values specified by Japanese Industrial Standards. It is found that the hot wire anemometer installed downstream in the vicinity of the valve is suitable for detecting the change in flowrate with the response time of less than 1 ms.

  1. ENERGY EFFICIENT AND SAFE VALVE TESTING UNIT USING WIRELESS TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    V. Dhivya

    2013-04-01

    Full Text Available The valve testing unit is a high pressure test equipment to test the valve manufactured in industries. Valves are tested to ensure that they sustain high pressure in the range of 10000 to 15000 PSI for the required amount of time without any leakage. It has few drawbacks such as inefficient usage of power, fatal accidents due to the proximity of the users with the testing unit to note the valve pressure during operation. It is much dangerous for the industry personnel to note the valve pressure for every minute during operation. There are chances of bolts fitted in the valve thrown away due to the issues in the bolt fittings and the immense pressure inside the valve. Therefore in order to avoid fatal accidents andto improve the industrial safety an efficient valve testing unit is designed and developed using ZigBee wireless transmission technology. The proposed efficient pressure monitoring unit uses emerging technologies like ZigBee, RFID along with ARM 7 processor. The proposed system uses LabVIEW software to develop the monitoring unit in PC. ZigBee wireless transmission technology is used for remote monitoring of valve pressure for every minute. RFID module is used for uniquely identifying the valve and to track the test results. The proposed unit saves energy by sending a signal to turn off the air driven booster pump once the prescribed pressure level is reached. Theproposed unit also indicates the oil level of the test unit which avoids the manual intervention to verify the oil level and also detects issues in the bolts fitted in the valve by using a distance sensor which is to avoid fatal accidents by stopping the valve testing unit.

  2. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  3. JenaValve.

    Science.gov (United States)

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  4. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  5. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves

    DEFF Research Database (Denmark)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann

    2017-01-01

    AIMS: Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, at smaller sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be frac...

  6. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  7. Mitral valve prolapse.

    Science.gov (United States)

    Gould, L; Gopalaswamy, C

    1984-05-01

    Mitral valve prolapse is a very common condition. It occurs in 4-5% of the population. It may be idiopathic or associated with a number of other conditions. Myxomatous degeneration is the underlying mechanism of mitral valve prolapse. Most patients with mitral valve prolapse have no symptoms. When symptoms do occur, palpitations, chest pain and dyspnea are the major complaints. The midsystolic click occasionally followed by the late systolic murmur are the typical physical findings. The echocardiogram plays a big role in the diagnosis of mitral valve prolapse. The beta blockers are used in the treatment of the symptomatic patient.

  8. Biological heart valves.

    Science.gov (United States)

    Ciubotaru, Anatol; Cebotari, Serghei; Tudorache, Igor; Beckmann, Erik; Hilfiker, Andres; Haverich, Axel

    2013-10-01

    Cardiac valvular pathologies are often caused by rheumatic fever in young adults, atherosclerosis in elderly patients, or by congenital malformation of the heart in children, in effect affecting almost all population ages. Almost 300,000 heart valve operations are performed worldwide annually. Tissue valve prostheses have certain advantages over mechanical valves such as biocompatibility, more physiological hemodynamics, and no need for life-long systemic anticoagulation. However, the major disadvantage of biological valves is related to their durability. Nevertheless, during the last decade, the number of patients undergoing biological, rather than mechanical, valve replacement has increased from half to more than three-quarters for biological implants. Continuous improvement in valve fabrication includes development of new models and shapes, novel methods of tissue treatment, and preservation and implantation techniques. These efforts are focused not only on the improvement of morbidity and mortality of the patients but also on the improvement of their quality of life. Heart valve tissue engineering aims to provide durable, "autologous" valve prostheses. These valves demonstrate adaptive growth, which may avoid the need of repeated operations in growing patients.

  9. A piezoelectrically actuated ball valve

    Science.gov (United States)

    Erwin, L. R.; Schwartz, H. W.; Teitelbaum, B. R.

    1972-01-01

    Bimorph strip composed of two layers of poled piezoelectric ceramic material closes and opens valve. Strip performs like capacitator, allowing initial inrush of current when valve is energized and then only small leakage current flows as valve remains energized.

  10. Water system microbial check valve development

    Science.gov (United States)

    Colombo, G. V.; Greenley, D. R.; Putnam, D. F.

    1978-01-01

    A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

  11. MODELING THE GROWTH OF Eucalyptus CLONES USING THE CHAPMAN-RICHARDS MODEL WITH DIFFERENT SYMMETRICAL ERROR DISTRIBUTIONS

    Directory of Open Access Journals (Sweden)

    Luiz Medeiros de Araujo Lima Filho

    2012-12-01

    Full Text Available http://dx.doi.org/10.5902/198050987558The objective of this work was to estimate the height growth of Eucalyptus using the Chapman-Richards model considering for the errors the distributions normal, Student t (t and Cauchy. The data set came from a hybrid of Eucalyptus urophylla x Eucalyptus tereticornis x E. pellita (controlled pollination, of the Forestry Experimental Module in the Gypsum Pole of Araripe, established in 2002. Eighty-three trees were used which heights were measured in all trees for six and half years. The fittings consisted on the estimation of the parameters of the Chapman-Richards model maximizing the log-likelihood of the error distributions using the symmetric distributions normal, t and Cauchy. For comparison of the adjusted models were used the criteria of Akaike Information Criterion (AIC and Bayesian (BIC and the mean absolute percentage error (MAPE. The model using the t distribution with 2 degrees of freedom (t2 had lower values of AIC and BIC and the model of Cauchy had lower value for MAPE. The results indicate that the model considering the t distribution for the errors presented best estimates of height growth of Eucalyptus clones in Gypsum Pole of Pernambuco.

  12. Experimental Validation of Mathematical Framework for Fast Switching Valves used in Digital Hydraulic Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Roemer, Daniel Beck; Bech, Michael Møller

    2015-01-01

    A prototype of a fast switching valve designed for a digital hydraulic transmission has been manufactured and experimentally tested. The valve is an annular seat valve composed of a plunger connected with a direct electromagnetic moving coil actuator as the force producing element. Based on an el......A prototype of a fast switching valve designed for a digital hydraulic transmission has been manufactured and experimentally tested. The valve is an annular seat valve composed of a plunger connected with a direct electromagnetic moving coil actuator as the force producing element. Based...... of 10 kW during switching (mean of approximately 250 W) and a pressure loss below 0.5 bar at 600 l/min. The main goal of this article is validate parts of the mathematical framework based on a series of experiments. Furthermore, this article aims to document the experience gained from the experimental...... work and to study and assess a moving coil actuators suitability for the application....

  13. Water Hydraulic 2/2 Directional Valve with Plane Piston Structure

    Institute of Scientific and Technical Information of China (English)

    GONG Yongjun; YANG Huayong; WANG Zuwen

    2009-01-01

    Due to the fire resistance and environmental compatibility, using water as the working fluid in hydraulic circuits is receiving an increasing attention by both manufactures and users. This hydraulic directional valve is developed. When new water hydraulic directional valve is designed and manufactured, this paper introduces a water hydraulic 2/2 directional valve and its principle. The valve is composed of a hydraulically operated seat valve and a magnetic 3/2 direction valve. Aimed at the serious leakage and impact generating easily in reversing suddenly, an improved structure of water space seal is changed to direct seal, compaction force between main valve spool and main valve pocket was logically designed and damper in pilot valve port is matched with sensitive cavity in main valve. From the view of flow control, the methods of cavitation resistance of the directional water hydraulic valve are investigated. The computational fluid dynamics approaches are applied to obtain static pressure distributions and cavitation images in the channel of the main stage of the valve with two kinds of structure. The results show that the method of optimized spout can effectively restrain cavitation. The work provides some useful reference for developing water hydraulic control valve with the Dower noise and lower vibration. Meantime, the structural parameters are optimized on the basis of information obtained from simulation. Static test, dynamic test and life test are accomplished, and the results show that the water hydraulic directional valve possesses good property, its pressure loss is 1.1 MPa lower, switching time is shorter than 0.025 s, and its strike crest is 0.8 MPa lower. The valve possess fine dynamic performance with the characteristic rapidly action and lower implusion.

  14. Mitral valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  15. Blocked Urethral Valves

    Science.gov (United States)

    ... Blocked Urethral Valves Health Issues Listen Español Text Size Email Print Share Blocked Urethral Valves Page Content Article Body Urine leaves the bladder through a tube called the urethra, which in boys passes through the penis. Rarely, small membranes form across the urethra in ...

  16. Shutoff and throttling valve

    Science.gov (United States)

    Hays, L. G.

    1974-01-01

    Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

  17. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering.

  18. Anticoagulation for Prosthetic Valves

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kaneko

    2013-01-01

    Full Text Available Implantation of prosthetic valve requires consideration for anticoagulation. The current guideline recommends warfarin on all mechanical valves. Dabigatran is the new generation anticoagulation medication which is taken orally and does not require frequent monitoring. This drug is approved for treatment for atrial fibrillation and venous thromboembolism, but the latest large trial showed that this drug increases adverse events when used for mechanical valve anticoagulation. On-X valve is the new generation mechanical valve which is considered to require less anticoagulation due to its flow dynamics. The latest study showed that lower anticoagulation level lowers the incidence of bleeding, while the risk of thromboembolism and thrombosis remained the same. Anticoagulation poses dilemma in cases such as pregnancy and major bleeding event. During pregnancy, warfarin can be continued throughout pregnancy and switched to heparin derivative during 6–12 weeks and >36 weeks of gestation. Warfarin can be safely started after 1-2 weeks of discontinuation following major bleeding episode.

  19. Flow characteristics and performance evaluation of butterfly valves using numerical analysis

    Science.gov (United States)

    Jeon, S. Y.; Yoon, J. Y.; Shin, M. S.

    2010-08-01

    The industrial butterfly valves have been applied to various fields that transport fluid in volume, especially water supply and drainage pipeline for flow control. The butterfly valves in various shapes are manufactured, but a fitting performance comparison is not made up. For this reason, we carried out numerical analysis of some kind of butterfly valves for water supply and drainage pipeline using commercial CFD code FLUENT, and made a comparative study of these results. Also, the flow coefficient, the loss coefficient, and pressure distribution of valves according to valve opening rate were compared each other and the influence of these design variables on valve performance were checked over. Through flow around the valve disk, such as pressure distribution, flow pattern, velocity vectors, and form of vortex, we grasped flow characteristics.

  20. Proceedings of the 2nd symposium on valves for coal conversion and utilization

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, D.A. (ed.)

    1981-01-01

    The 2nd symposium on valves for coal conversion and utilization was held October 15 to 17, 1980. It was sponsored by the US Department of Energy, Morgantown Energy Technology Center, in cooperation with the Valve Manufacturers Association. Seventeen papers have been entered individually into EDB and ERA. (LTN)

  1. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  2. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  3. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  4. A new species of Trichuris Roederer, 1761 (Nematoda: Trichuridae) from Heteromys gaumeri Allen & Chapman (Rodentia: Heteromyidae) in Yucatan, Mexico.

    Science.gov (United States)

    Panti-May, Jesús Alonso; Robles, María Del Rosario

    2016-09-01

    In Mexico, four species of Trichuris Roederer, 1761 have been recorded in wild rodents belonging to the family Heteromyidae. In the present paper, we describe a new species based on specimens collected from Heteromys gaumeri Allen & Chapman (Heteromyidae: Heteromyinae) in the tropical forests of the Yucatan Peninsula, Mexico. Trichuris silviae n. sp. can be differentiated from the congeners described in North and South American rodents by morphological and morphometric features, such as the possession of a wide spicular tube, a thicker proximal cloacal tube, a shorter distal cloacal tube and a cylindrical spicular sheath. This is the first description of a Trichuris spp. from heteromyid rodents in Mexico and the fourth in North America. Despite the broad distribution of Heteromys spp., few cases of Trichuris infection have been reported. Further studies are necessary to verify if the new species is present in other heteromyid rodents in order to increase our knowledge about its geographical and host distribution.

  5. Plate impact experiments on the TATB based explosive PBX 9502 at pressures near the Chapman-Jouguet state

    Science.gov (United States)

    Gustavsen, R. L.; Aslam, T. D.; Bartram, B. D.; Hollowell, B. C.

    2014-05-01

    A series of two-stage gus-gun driven plate impact experiments on PBX 9502 (95 wt.% tri-amino-trinitro-benzene, 5 wt.% Kel-F800 plastic binder) was completed in the 28-34 GPa pressure range. This is just above the Chapman-Jouguet state of ≈ 28 GPa. The experiments consisted of a thick oxygen free high conductivity copper (OFHC Cu) flyer plate impacting a PBX 9502 sample backed by a Lithium Fluoride (LiF) window. Photonic Doppler Velocimetry (PDV) was used to measure velocity histories (wave profiles) at the PBX 9502/LiF interface. Shock transit times and sample thicknesses were converted to shock velocities, Us. Particle velocities, up, were calculated by way of impedance matching. Lastly, the measured wave profiles were compared with numerical simulations of the experiments using the Wescott-Stewart-Davis reactive-burn model.

  6. Mesofluidic two stage digital valve

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  7. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...

  8. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  9. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...... method that can be used to predict the performance of valves....

  10. A valve disk

    Energy Technology Data Exchange (ETDEWEB)

    Khayrullin, N.A.; Isayev, B.N.; Kruglov, S.A.; Molokanov, Yu.K.; Shchelkunov, V.A.; Shegay, V.R.; Vizhgorodskiy, B.N.

    1982-01-01

    A valve disk is proposed which includes a horizontal bed, on which there are laminar valves arranged in staggered order. To ensure the stable and effective operation of the disk in a broad range of loads by compensating for the direct flow and the partial sectioning of the disk bed, it is equipped with compensating elements installed in openings in the bed and hinged with it. They are made in the form of straight, triangular prisms with ports in the bases. The prisms are installed with the capability of movement relative to the disk bed. The valves are positioned on the upper lateral facets of the compensating elements.

  11. Computational manufacturing

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    This paper presents a general framework for computational manufacturing. The methodology of computational manufacturing aims at integrating computational geometry, machining principle, sensor information fusion, optimization, computational intelligence and virtual prototyping to solve problems of the modeling, reasoning, control, planning and scheduling of manufacturing processes and systems. There are three typical problems in computational manufacturing, i.e., scheduling (time-domain), geometric reasoning (space-domain) and decision- making (interaction between time-domain and space-domain). Some theoretical fundamentals of computational manufacturing are also discussed.

  12. Surgical double valve replacement after transcatheter aortic valve implantation and interventional mitral valve repair.

    Science.gov (United States)

    Wendeborn, Jens; Donndorf, Peter; Westphal, Bernd; Steinhoff, Gustav

    2013-11-01

    Transcatheter aortic valve implantation, as well as interventional mitral valve repair, offer reasonable therapeutic options for high-risk surgical patients. We report a rare case of early post-interventional aortic valve prosthesis migration to the left ventricular outflow tract, with paravalvular leakage and causing severe mitral valve regurgitation. Initial successful interventional mitral valve repair using a clipped edge-to-edge technique revealed, in a subsequent procedure, the recurrence of mitral valve regurgitation leading to progressive heart failure and necessitating subsequent surgical aortic and mitral valve replacement.

  13. Pressure control valve using proportional electro-magnetic solenoid actuator

    Energy Technology Data Exchange (ETDEWEB)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2006-10-15

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed.

  14. Mitral Valve Disease

    Science.gov (United States)

    ... for more information on procedures, news, and pre- & post-operative care. Section Navigation Select Topic Aortic Valve Disease ... is most commonly caused by inflammation from rheumatic fever, a disease that is related to strep infections; ...

  15. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  16. Pulmonary valve stenosis

    Science.gov (United States)

    ... valvuloplasty - pulmonary Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  17. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  18. Mitral Valve Prolapse

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  19. Valve development for coal gasification plants: Phase I to Phase II transition. Quarterly technical program report, May--July 1978

    Energy Technology Data Exchange (ETDEWEB)

    Bellezza, D.

    1978-08-01

    This is the eighth in a series of Quarterly Technical Progress Reports relating to the Valve Development for Coal Gasification Plants Program. This document discusses engineering progress during the period of May to July 1978. The work described herein represents a continuation of the Phase I seat development effort for the Task III valve and the continuation of design engineering effort, necessary to prepare detail manufacturing drawings for use in the production of prototype valves during Phase II of this program. Work performed during this quarter consists of: valve design, thermal and stress analysis of valves, design detailing and specifications, quality assurance planning and various tests as outlined.

  20. Precision manufacturing

    CERN Document Server

    Dornfeld, David

    2008-01-01

    Today there is a high demand for high-precision products. The manufacturing processes are now highly sophisticated and derive from a specialized genre called precision engineering. Precision Manufacturing provides an introduction to precision engineering and manufacturing with an emphasis on the design and performance of precision machines and machine tools, metrology, tooling elements, machine structures, sources of error, precision machining processes and precision process planning. As well as discussing the critical role precision machine design for manufacturing has had in technological developments over the last few hundred years. In addition, the influence of sustainable manufacturing requirements in precision processes is introduced. Drawing upon years of practical experience and using numerous examples and illustrative applications, David Dornfeld and Dae-Eun Lee cover precision manufacturing as it applies to: The importance of measurement and metrology in the context of Precision Manufacturing. Th...

  1. The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography.

    Science.gov (United States)

    Lee, Dong-Hyeon; Youn, Ho-Joong; Shim, Sung-Bo; Lee, Sun-Hee; Jung, Jung-Im; Jung, Seung-Eun; Choi, Yun-Seok; Park, Chul-Soo; Oh, Yong-Seog; Chung, Wook-Sung; Kim, Jae-Hyung

    2009-04-01

    The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). In 20 patients (mean age, 50+/-12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening and closing angles were measured using a protractor. The OA and length of the mechanical valves were compared with the manufacturer's values. The geometric orifice areas (GOAs) based on the manufacturer's values and the OAs determined by MDCT were 3.4+/-0.2 cm(2) and 3.4+/-0.3 cm(2) for the mitral valves and 2.1+/-0.3 cm(2) and 2.1+/-0.4 cm(2) for the aortic valves, respectively. The correlation coefficients between the OA measures were 0.433 for the mitral valves and 0.874 for the aortic valves (both pvalves and 21.5+/-2.1 mm and 20.7+/-2.3 mm for the aortic valves, respectively. The correlation coefficients between the measures were 0.651 for the mitral valve and 0.846 for the aortic valve (both pvalves and 11.1+/-0.9 degrees and 120.6+/-1.7 degrees for the aortic valves, respectively. MDCT is an accurate modality with which to assess the function and morphology of bileaflet mechanical valves.

  2. Investigating the characteristics of shutoff valves by model tests

    Energy Technology Data Exchange (ETDEWEB)

    Strohmer, F.

    1977-07-01

    High pressures, strict safety requirements, minimum wear and a decrease of head losses are nowadays the most essential criteria in the design and manufacture of shutoff valves for water powerplants. In the following, the results of such model tests carried out in the hydraulic laboratory of Voeest Alpine AG are described.

  3. Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles

    Science.gov (United States)

    Dunn, V. B.

    1975-01-01

    A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

  4. EGS Richardson AGU Chapman NVAG3 Conference: Nonlinear Variability in Geophysics: scaling and multifractal processes

    Science.gov (United States)

    Schertzer, D.; Lovejoy, S.

    1. The conference The third conference on "Nonlinear VAriability in Geophysics: scaling and multifractal processes" (NVAG 3) was held in Cargese, Corsica, Sept. 10-17, 1993. NVAG3 was joint American Geophysical Union Chapman and European Geophysical Society Richardson Memorial conference, the first specialist conference jointly sponsored by the two organizations. It followed NVAG1 (Montreal, Aug. 1986), NVAG2 (Paris, June 1988; Schertzer and Lovejoy, 1991), five consecutive annual sessions at EGS general assemblies and two consecutive spring AGU meeting sessions. As with the other conferences and workshops mentioned above, the aim was to develop confrontation between theories and experiments on scaling/multifractal behaviour of geophysical fields. Subjects covered included climate, clouds, earthquakes, atmospheric and ocean dynamics, tectonics, precipitation, hydrology, the solar cycle and volcanoes. Areas of focus included new methods of data analysis (especially those used for the reliable estimation of multifractal and scaling exponents), as well as their application to rapidly growing data bases from in situ networks and remote sensing. The corresponding modelling, prediction and estimation techniques were also emphasized as were the current debates about stochastic and deterministic dynamics, fractal geometry and multifractals, self-organized criticality and multifractal fields, each of which was the subject of a specific general discussion. The conference started with a one day short course of multifractals featuring four lectures on a) Fundamentals of multifractals: dimension, codimensions, codimension formalism, b) Multifractal estimation techniques: (PDMS, DTM), c) Numerical simulations, Generalized Scale Invariance analysis, d) Advanced multifractals, singular statistics, phase transitions, self-organized criticality and Lie cascades (given by D. Schertzer and S. Lovejoy, detailed course notes were sent to participants shortly after the conference). This

  5. EGS Richardson AGU Chapman NVAG3 Conference: Nonlinear Variability in Geophysics: scaling and multifractal processes

    Directory of Open Access Journals (Sweden)

    D. Schertzer

    1994-01-01

    Full Text Available 1. The conference The third conference on "Nonlinear VAriability in Geophysics: scaling and multifractal processes" (NVAG 3 was held in Cargese, Corsica, Sept. 10-17, 1993. NVAG3 was joint American Geophysical Union Chapman and European Geophysical Society Richardson Memorial conference, the first specialist conference jointly sponsored by the two organizations. It followed NVAG1 (Montreal, Aug. 1986, NVAG2 (Paris, June 1988; Schertzer and Lovejoy, 1991, five consecutive annual sessions at EGS general assemblies and two consecutive spring AGU meeting sessions. As with the other conferences and workshops mentioned above, the aim was to develop confrontation between theories and experiments on scaling/multifractal behaviour of geophysical fields. Subjects covered included climate, clouds, earthquakes, atmospheric and ocean dynamics, tectonics, precipitation, hydrology, the solar cycle and volcanoes. Areas of focus included new methods of data analysis (especially those used for the reliable estimation of multifractal and scaling exponents, as well as their application to rapidly growing data bases from in situ networks and remote sensing. The corresponding modelling, prediction and estimation techniques were also emphasized as were the current debates about stochastic and deterministic dynamics, fractal geometry and multifractals, self-organized criticality and multifractal fields, each of which was the subject of a specific general discussion. The conference started with a one day short course of multifractals featuring four lectures on a Fundamentals of multifractals: dimension, codimensions, codimension formalism, b Multifractal estimation techniques: (PDMS, DTM, c Numerical simulations, Generalized Scale Invariance analysis, d Advanced multifractals, singular statistics, phase transitions, self-organized criticality and Lie cascades (given by D. Schertzer and S. Lovejoy, detailed course notes were sent to participants shortly after the

  6. Implantation of the CoreValve percutaneous aortic valve.

    Science.gov (United States)

    Lamarche, Yoan; Cartier, Raymond; Denault, André Y; Basmadjian, Arsène; Berry, Colin; Laborde, Jean-Claude; Bonan, Raoul

    2007-01-01

    Surgical aortic valve replacement is the only recommended treatment for significant aortic valve stenosis. Percutaneous aortic valve replacement appears to be a novel option for high-risk patients. We report the implantation of the ReValving system (CoreValve, Paris, France) in a 64-year-old woman who was refused aortic valve replacement surgery for critical aortic stenosis and left ventricular dysfunction because of severe pulmonary fibrosis. After anesthesia, the patient was put on femorofemoral cardiopulmonary bypass, and underwent a balloon valvuloplasty with subsequent retrograde aortic valve replacement by the ReValving system. Transesophageal echocardiographic monitoring of the patient's hemodynamics showed immediate improvements of the valvular area and left ventricular ejection fraction and only traces of paravalvular leaks. The patient was easily weaned from ventilation and resumed activity soon after the surgery. A multidisciplinary approach is presently necessary to offer a reliable and safe procedure.

  7. Experimental Validation of Modelled Fluid Forces in Fast Switching Hydraulic On/Off Valves

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck;

    2015-01-01

    A prototype of a fast switching valve for a digital hydraulic machine has been designed and manufactured. The valve is composed of an annular seat plunger connected with a moving coil actuator as the force producing element. The valve prototype is designed for flow rates of 600 l/min with less than...... 0.5 bar pressure drop, and the models predicts a switching time in the region of a millisecond with a travel length of 3.5 mm using an average power of 250 W. The total machine efficiency when neglecting losses not related to the valves is above 98 %. The objective of this paper is to experimentally...... validate a transient computational fluid dynamics (CFD) model of the fluid forces that oppose the valve plunger when moving rapidly through the surrounding oil during switching. Due to the fast switching of the valve, the fluid forces which oppose plunger movement increases drastically as the plunger...

  8. [Technologies for cardiac valve prostheses].

    Science.gov (United States)

    Nakano, Kiyoharu

    2009-07-01

    To show the technological development of cardiac valve prostheses, a historical review of both mechanical and biological valve prostheses and a current overview of modern cardiac valve devices are provided. Scince the 1st implantation of Starr-Edwards ball valve in 1960, both mechanical and biological valve prostheses have advanced. The valve design, the material of the leaflet and the hausing of mechanical prostheses have improved. Currently, the majority of the mechanical prostheses are bileaflet tilting disc valves made of pyrolytic carbon, which is antithromboembolic. However, anticoagulation therapy with warfarin is still required. As for the bioprostheses, although the fixation and anti-mineralization methods of the tissues improved, the durability of these valves is still limited. For the material of the current biological valves, the porcine aortic valve or bovine pericardium are used. The tissues are fixed by non-pressure or low-pressure method in glutaraldehyde solution. A stented and non-stented valves are available. Epoch-making events in this field are the implantation of new bioprosthetic valves using tissue engineering methods and the development of the transcatheter valve replacement therapies.

  9. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen;

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.......Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  10. Failure Modes and Causes for Swing and Lift Type Check Valves.

    Energy Technology Data Exchange (ETDEWEB)

    McElhaney, K.L.

    1997-12-31

    Prior to the recent work performed by Oak Ridge National Laboratory (ORNL)relative to nuclear industry check valve performance, no information was readily available regarding the failure characteristics of check valves based on valve type (e.g., swing check, lift check). Although it had been recognized by component experts that the two most significant factors in determining check valve performance were valve design (i.e., type) and operating conditions, no industry data was available relative to the former. In cooperation with the Nuclear Industry Check Valve Group (NIC), ORNL has reviewed and analyzed check valve failures from the Institute of Nuclear Power Operations` (INPOs`) Nuclear Plant Reliability Database System (NPRDS) according to several parameters,including valve type. Since the valve type identification is not inherently included within the NPRDS engineering record for each component, ORNL had to rely upon input from NIC, valve manufacturers, and catalogs to supply the missing information. As a result of this effort, approximately 77% of the check valve failures occurring during the 1991-1996 study period and nearly 62% of the overall installed population were identified according to type. This data provided the basis to perform previously unavailable cross-correlations between parameters such as valve type versus failure mode and failure cause. Design characteristics and service applications differ markedly among check valve types, resulting in discernible differences in performance. This paper focuses on the performance characteristics of swing and lift type check valves since failure and population distributions have shown these to be the two most common types employed in a wide range of nuclear plant applications.

  11. Mitral Valve Aneurysm: A Rare Complication of Aortic Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    A Moaref

    2008-11-01

    Full Text Available A 20-year-old intravenous drug abuser man, refered to our hospital with dyspnea and orthopnea. Tranesophagealechocardiography revealed severe aortic regurgitation, healed vegetation of aortic valve and an aneurysm of theanterior leaflet of the mitral valve. The patient was discharged after aortic valve replacement and mitral valverepair.

  12. Research on Valve Body Design of Large Bore Sodium Valve

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Large bore sodium valve is one kind of key equipments of China Demonstration Fast Reactor (CDFR). It is installed in the pipeline before and behind SG units as a locking mechanism. Valve body which is used to bear pressure is the core of sodium valve design.

  13. Manufacturing technologies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Manufacturing Technologies Center is an integral part of Sandia National Laboratories, a multiprogram engineering and science laboratory, operated for the Department of Energy (DOE) with major facilities at Albuquerque, New Mexico, and Livermore, California. Our Center is at the core of Sandia`s Advanced Manufacturing effort which spans the entire product realization process.

  14. Manufacturing Interfaces

    NARCIS (Netherlands)

    Houten, van F.J.A.M.

    1992-01-01

    The paper identifies the changing needs and requirements with respect to the interfacing of manufacturing functions. It considers the manufacturing system, its components and their relationships from the technological and logistic point of view, against the background of concurrent engineering. Desi

  15. Transcatheter Aortic Heart Valve Thrombosis

    DEFF Research Database (Denmark)

    Hansson, Nicolaj C; Grove, Erik L; Andersen, Henning R;

    2016-01-01

    BACKGROUND: There is increasing focus on transcatheter heart valve (THV) thrombosis. However, there are limited data on incidence, clinical implications and predisposing factors of THV thrombosis following transcatheter aortic valve replacement (TAVR). OBJECTIVES: We assessed the incidence...

  16. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  17. Prevention of crack initiation in valve bodies under thermal shock

    Energy Technology Data Exchange (ETDEWEB)

    Delmas, J.; Coppolani, P.

    1996-12-01

    On site and testing experience has shown that cracking in valves affects mainly the stellite hardfacing on seats and discs but may also be a concern for valve bodies. Metallurgical investigations conducted by EDF laboratories on many damaged valves have shown that most of the damage had either a chemical, manufacturing, or operating origin with a strong correlation between the origins and the type of damage. The chemical defects were either excess ferritic dilution of stellite or excess carburizing. Excess carburizing leads to a too brittle hardfacing which cracks under excessive stresses induced on the seating surfaces, via the stem, by too high operating thrusts. The same conditions can also induce cracks of the seats in the presence, in the hardfacing, of hidden defects generated during the welding process. Reduction of the number of defects results first from controls during manufacturing, mainly in the thickness of stellite. On the other hand, maintenance must be fitted to the type of defect. In-situ lapping may lead to release of cobalt, resulting in contamination of the circuit. Furthermore, it is ineffectual in the case of a crack through the seating surface, as is often found on globe valves. The use of new technologies of valves with removable seats and cobalt-free alloys solves permanently this kind of problem.

  18. Nasal valve surgery.

    Science.gov (United States)

    Apaydin, Fazil

    2011-04-01

    Nasal obstruction can be due to internal and external valve problems that can be seen before and after rhinoplasty. The main scope of this article is to concentrate on surgical solutions to these problems. To overcome nasal obstruction at the internal valve, spreader grafts, spreader flaps, upper lateral splay graft, butterfly graft, flaring suture, M-plasty, Z-plasty, and suspension sutures have been described. The management of the external valve problems is possible by using lateral crural dissection and repositioning, lateral crural strut grafts, alar battens, lateral crural turn-in flap, alar rim grafts, and various other methods. It is not easy to decide which techniques would work best in every case. After a thorough examination and analysis, the underlying cause of the nasal obstruction can be understood, and one or multiple procedures can be chosen according to each individual problem.

  19. Percutaneous mitral valve repair.

    Science.gov (United States)

    Gillinov, A Marc; Liddicoat, John R

    2006-01-01

    Surgical mitral valve repair is the procedure of choice to treat mitral regurgitation of all etiologies. Whereas annuloplasty is the cornerstone of mitral valve repair, a variety of other surgical techniques are utilized to correct dysfunction of the leaflets and subvalvular apparatus; in most cases, surgical repair entails application of multiple repair techniques in each patient. Preclinical studies and early human experience have demonstrated that some of these surgical repair techniques can be performed using percutaneous approaches. Specifically, there has been great progress in the development of novel technology to facilitate percutaneous annuloplasty and percutaneous edge-to-edge repair. The objectives of this report were to (1) discuss the surgical foundations for these percutaneous approaches; (2) review device design and experimental and clinical results of percutaneous valve repair; and (3) address future directions, including the key challenges of patient selection and clinical trial design.

  20. Mixtures of relativistic gases in gravitational fields: Combined Chapman-Enskog and Grad method and the Onsager relations

    Science.gov (United States)

    Moratto, Valdemar; Kremer, Gilberto M.

    2015-05-01

    In this work we study an r -species mixture of gases within the relativistic kinetic theory point of view. We use the relativistic covariant Boltzmann equation and incorporate the Schwarzschild metric. The method of solution of the Boltzmann equation is a combination of the Chapman-Enskog and Grad representations. The thermodynamic four-fluxes are expressed as functions of the thermodynamic forces so the generalized expressions for the Navier-Stokes, Fick, and Fourier laws are obtained. The constitutive equations for the diffusion and heat four-fluxes of the mixture are functions of thermal and diffusion generalized forces which depend on the acceleration and the gravitational potential gradient. While this dependence is of relativistic nature for the thermal force, this is not the case for the diffusion forces. We show also that the matrix of diffusion coefficients is symmetric, implying that the thermal-diffusion equals the diffusion-thermal effect, proving the Onsager reciprocity relations. The entropy four-flow of the mixture is also expressed in terms of the thermal and diffusion generalized forces, so its dependence on the acceleration and gravitational potential gradient is also determined.

  1. Prediction of the Chapman-Jouguet chemical equilibrium state in a detonation wave from first principles based reactive molecular dynamics.

    Science.gov (United States)

    Guo, Dezhou; Zybin, Sergey V; An, Qi; Goddard, William A; Huang, Fenglei

    2016-01-21

    The combustion or detonation of reacting materials at high temperature and pressure can be characterized by the Chapman-Jouguet (CJ) state that describes the chemical equilibrium of the products at the end of the reaction zone of the detonation wave for sustained detonation. This provides the critical properties and product kinetics for input to macroscale continuum simulations of energetic materials. We propose the ReaxFF Reactive Dynamics to CJ point protocol (Rx2CJ) for predicting the CJ state parameters, providing the means to predict the performance of new materials prior to synthesis and characterization, allowing the simulation based design to be done in silico. Our Rx2CJ method is based on atomistic reactive molecular dynamics (RMD) using the QM-derived ReaxFF force field. We validate this method here by predicting the CJ point and detonation products for three typical energetic materials. We find good agreement between the predicted and experimental detonation velocities, indicating that this method can reliably predict the CJ state using modest levels of computation.

  2. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  3. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...... resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel....

  4. Pulsatile prosthetic valve flows.

    Science.gov (United States)

    Phillips, W M; Snyder, A; Alchas, P; Rosenberg, G; Pierce, W S

    1980-01-01

    The laser Doppler system has been established as a useful tool for eliciting the properties of simulated cardiovascular flows, and thus for comparative studies of flow properties of prosthetic valves. Significant differences among valve types and between models of one type have been documented. The complex variations of velocity profiles with time show that comparisons must be made for unsteady pulsatile rather than steady flow, despite the volume and complexity of the data required. Future studies will include methods of compacting the data presentation and improving the details of the experimental stimulation.

  5. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-12-31

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele`s pivot. The Schiele`s pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele`s pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele`s pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  6. Transcatheter Valve-in-Valve: A Cautionary Tale.

    Science.gov (United States)

    Luc, Jessica G Y; Shanks, Miriam; Tyrrell, Benjamin D; Welsh, Robert C; Butler, Craig R; Meyer, Steven R

    2016-09-01

    Transcatheter aortic valve replacement (TAVR) by valve-in-valve (VIV) implantation is an alternative treatment for high-risk patients with a degenerating aortic bioprosthesis. We present a case of transapical TAVR VIV with a 29-mm Edwards SAPIEN XT (ESV) (Edwards Lifesciences, Irvine, CA) into a 29-mm Medtronic Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, MN) in which unanticipated dilatation of the Freestyle bioprosthesis resulted in intraprocedural embolization of the TAVR valve, necessitating urgent conversion to a conventional surgical aortic valve replacement (AVR). Our experience suggests that TAVR VIV with the 29-mm ESV in the setting of a degenerated 29-mm Freestyle stentless bioprosthesis must be undertaken with caution.

  7. Micro Manufacturing

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard

    2003-01-01

    . If a micro manufacturing system isn’t designed rationally and correctly, it will be high-cost, unreliable, and not robust. For micro products and systems it is a continuously increasing challenge to create the operational basis for an industrial production. As the products through product development...... processes are made applicable to a large number of customers, the pressure in regard to developing production technologies that make it possible to produce the products at a reasonable price and in large numbers is growing. The micro/nano manufacturing programme at the Department of Manufacturing...

  8. Prosthetic valve thrombosis in a patient with mitral valve replacement.

    Science.gov (United States)

    Bilal, Muhammad; Khan, Muhammad Shahzeb; Haseeb, Abdul; Khan, Abdul Bari

    2015-07-01

    Prosthetic valve thrombosis within one year after mitral valve replacement is rarely seen in patients on warfarin therapy and without any risk factor. Here, we describe a case of a 39-year- old female, who presented with dyspnoea and shortness of breath 11 months after mitral valve replacement. The echocardiogram revealed severe valvular stenosis due to presence of clots on the mitral valve and restricted motion of the mitral leaflets. As a result of deterioration of general condition and haemodynamic un-stability, plan was made to re-operate for her valve replacement surgery. This case report highlights the diagnosis, prevention and management of patients with prosthetic valve thrombosis following mitral valve replacement.

  9. Funding to Support the Participation of Scientists Engaged in DOE Research in the 2008 AGU Chapman Conference on Biogeophysics. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Slater, Lee D.

    2009-05-11

    This project provided travel awards for scientists engaged in research relevant to the DOE mission to participate in the American Geophysical Union (AGU) Chapman Conference on Biogeophysics held October 13-16, 2008, in Portland, Maine (http://www.agu.org/meetings/chapman/2008/fcall/). The objective of this Chapman Conference was to bring together geophysicists, biophysicists, geochemists, geomicrobiologists, and environmental microbiologists that are leaders in their field and have a personal interest in exploring this new interdisciplinary field or are conducting multidisciplinary research with potential impact on biogeophysics in order to define the current state of the science, identify the critical questions facing the community and to generate a roadmap for establishing biogeophysics as a critical subdiscipline of earth science research. The sixty participants were an international group of academics, graduate students and scientists at government laboratories engaged in biogeophysics related research. Scientists from Europe, Israel and China traveled to engage North American colleagues in this highly focused 3.5 day meeting. The group included an approximately equal mix of microbiologists, biogeochemists and near surface geophysicists. The recipients of the DOE travel awards were [1] Dennis Bazylinski (University of Nevada, Las Vegas), [2] Yuri Gorby (Craig Venter Institute), [3] Carlos Santamarina (Georgia Tech), [4] Susan Hubbard (Lawrence Berkeley Laboratory), [5] Roelof Versteeg (Idaho National Laboratory), [6] Eric Roden (University of Wisconsin), [7] George Luther (University of Delaware), and [8] Jinsong Chen (Lawrence Berkeley Laboratory)

  10. Funding to Support the Participation of Scientists Engaged in DOE Research in the 2008 AGU Chapman Conference on Biogeophysics. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Slater, Lee D.

    2009-05-11

    This project provided travel awards for scientists engaged in research relevant to the DOE mission to participate in the American Geophysical Union (AGU) Chapman Conference on Biogeophysics held October 13-16, 2008, in Portland, Maine (http://www.agu.org/meetings/chapman/2008/fcall/). The objective of this Chapman Conference was to bring together geophysicists, biophysicists, geochemists, geomicrobiologists, and environmental microbiologists that are leaders in their field and have a personal interest in exploring this new interdisciplinary field or are conducting multidisciplinary research with potential impact on biogeophysics in order to define the current state of the science, identify the critical questions facing the community and to generate a roadmap for establishing biogeophysics as a critical subdiscipline of earth science research. The sixty participants were an international group of academics, graduate students and scientists at government laboratories engaged in biogeophysics related research. Scientists from Europe, Israel and China traveled to engage North American colleagues in this highly focused 3.5 day meeting. The group included an approximately equal mix of microbiologists, biogeochemists and near surface geophysicists. The recipients of the DOE travel awards were [1] Dennis Bazylinski (University of Nevada, Las Vegas), [2] Yuri Gorby (Craig Venter Institute), [3] Carlos Santamarina (Georgia Tech), [4] Susan Hubbard (Lawrence Berkeley Laboratory), [5] Roelof Versteeg (Idaho National Laboratory), [6] Eric Roden (University of Wisconsin), [7] George Luther (University of Delaware), and [8] Jinsong Chen (Lawrence Berkeley Laboratory)

  11. Ellipsoidal Chapman Function for Atmosphere of Relevance to Ionospheres of Jupiter, Saturn, and Titan. Contribution to Models JIRA, SIRA, and TIRA

    Science.gov (United States)

    Velinov, P.; Ruder, H.; Kostov, V.; Mateev, L.

    As a continuation of our investigations of ellipsoidal Chapman Che function of the atmospheres of oblate planets Velinov et al 2004 we present new calculations for the giant planets Jupiter and Saturn and its satellite Titan In the above mentioned paper Che function only for the north and south pole regions is presented There some computations for Che function for the ionosphere of Saturn only on latitudes 90 degree at different altitudes and solar zenith angles 45 60 75 80 83 85 87 90 93 95 97 and 100 degree are made This new paper presents the results of our work on the ellipsoidal Chapman function of oblate planetary bodies Here the calculations for Che function in the oblate planet atmospheres of giant planets from Jovian group for middle and lower latitudes including the equator in Tables 1 - 3 are presented Che function for a rotational ellipsoid depends on the oblateness and on the solar zenith angle altitude latitude and the solar declination A comparison between Che function and classical Chapman function Ch for a spherical planet is made The last function is applicable for the ionospheres of terrestrial planets Venus Earth and Mars This comparison shows the necessity of introducing Che function in numerical analysis of ionospheres of Jupiter Saturn and Titan The function Che determines more precisely the optical depth parameter for solar XUV radiation and also the particle depth parameter for galactic and solar cosmic ray particles The difference between evaluations of electron production rate profiles with Che and Ch

  12. Distortion of the CoreValve during transcatheter aortic valve-in-valve implantation due to valve dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Souteyrand, Geraud, E-mail: gsouteyrand@chu-clermontferrand.fr [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Wilczek, Krzysztof [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Innorta, Andrea; Camilleri, Lionel [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Chodor, Piotr [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Lusson, Jean-René; Motreff, Pascal [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Laborde, Jean-Claude [St. George' s Hospital, London (United Kingdom); Chabrot, Pascal; Durel, Nicolas [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France)

    2013-09-15

    Nowadays transcatheter aortic valve implantation (TAVI) is an accepted alternative to surgical aortic valve replacement for high-risk patients (pts). Successful TAVI procedures for failed aortic surgical bioprosthesis (TAV-in-SAV) have already been reported. In the presented two cases of TAV-in-SAV implantation a strut distortion of the stent was revealed on angiographic imaging and confirmed on control CT scan. In both procedures, a dislocation of the medtronic core valve (MCV) prosthesis during implantation led to valve retrieval, with a necessity of reloading it in the 18F introducer before subsequent implantation of the same valve in correct position.

  13. Valve Health Monitoring System Utilizing Smart Instrumentation

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  14. An electrochemical active valve

    NARCIS (Netherlands)

    Neagu, C.R.; Gardeniers, J.G.E.; Elwenspoek, M.; Kelly, J.J.

    1997-01-01

    A novel electrochemical microactuator was developed, which operates as an active valve. The microactuator consists of an electrochemical cell and a membrane that deflects because of the pressure of oxygen gas generated by electrolysis. Relatively large pressures (up to tens of bars) can be reached w

  15. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Ansanelli, E.

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  16. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  17. Aortic valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otton CM, Bowow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  18. Vent Relief Valve Test

    Science.gov (United States)

    2008-01-01

    Shown is the disassembly, examination, refurbishment and testing of the LH2 ( liquid hydrogen) and LOX (liquid oxygen) vent and relief valves for the S-IVB-211 engine stage in support of the Constellation/Ares project. This image is extracted from high definition video and is the highest resolution available.

  19. Micro Manufacturing

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard

    2003-01-01

    Manufacturing deals with systems that include products, processes, materials and production systems. These systems have functional requirements, constraints, design parameters and process variables. They must be decomposed in a systematic manner to achieve the best possible system performance....... If a micro manufacturing system isn’t designed rationally and correctly, it will be high-cost, unreliable, and not robust. For micro products and systems it is a continuously increasing challenge to create the operational basis for an industrial production. As the products through product development...... processes are made applicable to a large number of customers, the pressure in regard to developing production technologies that make it possible to produce the products at a reasonable price and in large numbers is growing. The micro/nano manufacturing programme at the Department of Manufacturing...

  20. Smart Manufacturing.

    Science.gov (United States)

    Davis, Jim; Edgar, Thomas; Graybill, Robert; Korambath, Prakashan; Schott, Brian; Swink, Denise; Wang, Jianwu; Wetzel, Jim

    2015-01-01

    Historic manufacturing enterprises based on vertically optimized companies, practices, market share, and competitiveness are giving way to enterprises that are responsive across an entire value chain to demand dynamic markets and customized product value adds; increased expectations for environmental sustainability, reduced energy usage, and zero incidents; and faster technology and product adoption. Agile innovation and manufacturing combined with radically increased productivity become engines for competitiveness and reinvestment, not simply for decreased cost. A focus on agility, productivity, energy, and environmental sustainability produces opportunities that are far beyond reducing market volatility. Agility directly impacts innovation, time-to-market, and faster, broader exploration of the trade space. These changes, the forces driving them, and new network-based information technologies offering unprecedented insights and analysis are motivating the advent of smart manufacturing and new information technology infrastructure for manufacturing.

  1. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  2. Measurement of reed valve kinematics

    Science.gov (United States)

    Fenkl, Michael; Dvořák, Václav; Vít, Tomáš

    2016-03-01

    The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  3. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Kalyani Nair; C V Muraleedharan; G S Bhuvaneshwar

    2003-06-01

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the performance of mechanical heart valves. The clinical performance of mechanical heart valves is also addressed. Efforts made in India in the development of mechanical heart valves are also discussed.

  4. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time.

  5. Electric actuator for the sempell gate valve

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, E.C.

    1996-12-01

    The automation of valves has a primary importance in the scope of central control and regulation of power generation processes in power plants and especially in nuclear power plants. AUMA WERNER RIESTER GmbH & Co. KG is considered a leading manufacturer of electric actuators for the automation of valves. More than 30 years experience in designing, developing, and manufacturing provide a sound basis for offering reliable products, especially for nuclear applications. The quality assurance system of AUMA was developed according to 10 CFR 50, Appendix B and has been consistently accomplished. The program was certified by the TUV Germany (Technical Authorized Inspection Agency), according to ISO-9001, in 1994. AUMA offers two actuator type ranges for application in nuclear power plants. The range SAI is qualified according to IEEE 382-1978 and is designed for inside containment. The range SAN is qualified according to IEEE 382-1985 and KTA 3504-1988 for use in non-radioactive applications in the nuclear power plants.

  6. Development of Advanced Ceramic Manufacturing Technology

    Energy Technology Data Exchange (ETDEWEB)

    Pujari, V.K.

    2001-04-05

    Advanced structural ceramics are enabling materials for new transportation engine systems that have the potential for significantly reducing energy consumption and pollution in automobiles and heavy vehicles. Ceramic component reliability and performance have been demonstrated in previous U.S. DOE initiatives, but high manufacturing cost was recognized as a major barrier to commercialization. Norton Advanced Ceramics (NAC), a division of Saint-Gobain Industrial Ceramics, Inc. (SGIC), was selected to perform a major Advanced Ceramics Manufacturing Technology (ACMT) Program. The overall objectives of NAC's program were to design, develop, and demonstrate advanced manufacturing technology for the production of ceramic exhaust valves for diesel engines. The specific objectives were (1) to reduce the manufacturing cost by an order of magnitude, (2) to develop and demonstrate process capability and reproducibility, and (3) to validate ceramic valve performance, durability, and reliability. The program was divided into four major tasks: Component Design and Specification, Component Manufacturing Technology Development, Inspection and Testing, and Process Demonstration. A high-power diesel engine valve for the DDC Series 149 engine was chosen as the demonstration part for this program. This was determined to be an ideal component type to demonstrate cost-effective process enhancements, the beneficial impact of advanced ceramics on transportation systems, and near-term commercialization potential. The baseline valve material was NAC's NT451 SiAION. It was replaced, later in the program, by an alternate silicon nitride composition (NT551), which utilized a lower cost raw material and a simplified powder-processing approach. The material specifications were defined based on DDC's engine requirements, and the initial and final component design tasks were completed.

  7. Study on Friction and Wear Characteristics of Aluminum Alloy Hydraulic Valve Body and Its Antiwear Mechanism

    Directory of Open Access Journals (Sweden)

    Rong Li

    2017-03-01

    Full Text Available In order for the working status of the aluminum alloyed hydraulic valve body to be controlled in actual conditions, a new friction and wear design device was designed for the cast iron and aluminum alloyed valve bodies comparison under the same conditions. The results displayed that: (1 The oil leakage of the aluminum alloyed hydraulic valve body was higher than the corresponding oil leakage of the iron body during the initial running stage. Besides during a later running stage, the oil leakage of the aluminum alloyed body was lower than corresponding oil leakage of the iron body; (2 The actual oil leakage of different materials consisted of two parts: the foundation leakage that was the leakage of the valve without wear and wear leakage that was caused by the worn valve body; (3 The aluminum alloyed valve could rely on the dust filling furrow and melting mechanism that led the body surface to retain dynamic balance, resulting in the valve leakage preservation at a low level. The aluminum alloy modified valve body can meet the requirements of hydraulic leakage under pressure, possibly constituting this alloy suitable for hydraulic valve body manufacturing.

  8. Percutaneous tricuspid valve replacement in childhood

    Directory of Open Access Journals (Sweden)

    Mathias Emmel

    2015-01-01

    Full Text Available Percutaneous replacement of the tricuspid valve with a bovine jugular venous valve (melody valve was successfully undertaken in a 9-year-old boy. The patient had a previous history of bacterial endocarditis of the native tricuspid valve in infancy. Initially, a pericardial patch valve was created, followed by surgical replacement of the valve using a biological tissue valve at 4 years of age. Progressive stenosis and regurgitation of the biological valve, with severe venous congestion and resulting hepatic dysfunction prompted percutaneous valve replacement.

  9. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  10. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets fo...

  11. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  12. Chapman Conference: Magnetospheric Substorms

    Science.gov (United States)

    Iijima, Takesi; Kokubun, Susumu; Kan, Joseph R.; Potemra, T. A.

    Magnetospheric substorms are characterized by fascinating auroral displays in the ionosphere and by complex plasma dynamics in the magnetotail. The complicated plasma processes associated with substorms fascinated space researchers even before the space age, when observations were limited to the Earth's surface. These processes are believed to be fundamentally important to plasma physics, and also to apply to solar flares and other cosmic phenomena. Substorms have been the focus of intense study and controversy within space science for several decades.

  13. "Vanishing" pulmonary valve stenosis

    Directory of Open Access Journals (Sweden)

    Nofil I Arain

    2012-01-01

    Full Text Available Objective: Both spontaneous resolution and progression of mild pulmonary valve stenosis (PS have been reported. We reviewed characteristics of the pulmonary valve (PV to determine factors that could influence resolution of mild PS. Methods: Fifteen asymptomatic pediatric patients with spontaneous resolution of isolated mild PS were retrospectively reviewed. Results: There was no correlation between the PV gradient, clinical presentation, age at diagnosis, or PV morphology. The PV annulus was small at initial presentation, which normalized at follow up. When corrected for the body surface area (z-score, the PV annulus was normal in all patients, including at initial evaluation. Conclusions: Based on our observation, neither age at diagnosis, nor PV-morphology-influenced resolution of mild PS. The variable clinical presentation makes it difficult to categorize and observe mild PS by auscultation alone. The PV annulus z-score could be a useful adjunct to determine the course and serial observation of mild PS.

  14. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...

  15. Minimally Invasive Mitral Valve Replacement and Transfemoral Aortic Valve Implantation.

    Science.gov (United States)

    Rustenbach, Christian; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F W

    2015-01-01

    The case is reported of a symptomatic elderly patient with severe mitral regurgitation, severe aortic valve stenosis, and coronary heart disease. The coronary artery disease had been interventionally treated four years previously with stent implantation into the right coronary artery. Published studies have shown that a combination of mitral and aortic valve surgery is associated with a significantly increased risk of mortality and morbidity, particularly in elderly patients. In the present patient, both valvular malformations were successfully treated with a single-step interdisciplinary approach, namely an initial surgical mitral valve replacement followed by transfemoral transcatheter aortic valve replacement.

  16. In-plane cost-effective magnetically actuated valve for microfluidic applications

    Science.gov (United States)

    Pugliese, Marco; Ferrara, Francesco; Bramanti, Alessandro Paolo; Gigli, Giuseppe; Maiorano, Vincenzo

    2017-04-01

    We present a new in-plane magnetically actuated microfluidic valve. Its simple design includes a circular area joining two channels lying on the same plane. The area is parted by a septum lying on and adhering to a magneto-active polymeric ‘floor’ membrane, keeping the channels normally separated (valve closed). Under the action of a magnetic field, the membrane collapses, letting the liquid flow below the septum (valve open). The valve was extensively characterized experimentally, and modeled and optimized theoretically. The growing interest in lab on chips, especially for diagnostics and precision medicine, is driving researchers towards smart, efficient and low cost solutions to the management of biological samples. In this context, the valve developed in this work represents a useful building-block for microfluidic applications requiring precise flow control, its main features being easy and rapid manufacturing, biocompatibility and low cost.

  17. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  18. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  19. Supramolecular spin valves

    Science.gov (United States)

    Urdampilleta, M.; Klyatskaya, S.; Cleuziou, J.-P.; Ruben, M.; Wernsdorfer, W.

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc2 single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties.

  20. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  1. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, John J. (Bingham County, ID)

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  2. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  3. CFD analysis of a hydraulic valve for cavitating flow

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, A.; Goyal, P.; Singh, R.K.; Gosh, A.K. [Bhabha Atomic Research Centre (BARC), Trombay, Mumbai (India). Reactor Safety Div.

    2012-03-15

    A successful design of high pressure hydraulic valves requires a thorough analysis of both velocity and pressure fields, with the aim of improving the geometry to avoid cavitation. Cavitation behavior prediction of hydraulic valves and its associated performance drop is of high interest for the manufacturers and for the users. The paper presents a CFD analysis of the flow inside a high pressure hydraulic valve. First, the analysis was carried out without using cavitation model (single phase). It was observed that absolute pressure was going below the vapor pressure. Hence, it was required to turn on the cavitation model. This model enables formation of vapor from liquid when the pressure drops below the vaporization pressure. Since the cavitation bubble grows in a liquid at low temperature, the latent heat of evaporation can be neglected and the system can be considered isothermal. Under these conditions the pressure inside the bubble remains practically constant and the growth of the bubble radius can be approximated by the simplified Rayleigh equation. For typical poppet valve geometry, of computational domain is assumed, with pressure inlet and outlet boundary conditions, and a steady flow solution is computed. Because of the highly complex geometry of the hydraulic valve, the computational domain was meshed using unstructured grids using tetrahedral cells only. The paper presents a numerical investigation of the flow inside a hydraulic valve using commercial CFD code CFD-ACE. The aim of the study is to provide a good basis for future designing of the hydraulic valve. The result indicated the cavitation zones which in turn suggest needs of modification of present geometry. (orig.)

  4. Teflon films for chemically-inert microfluidic valves and pumps.

    Science.gov (United States)

    Grover, William H; von Muhlen, Marcio G; Manalis, Scott R

    2008-06-01

    We present a simple method for fabricating chemically-inert Teflon microfluidic valves and pumps in glass microfluidic devices. These structures are modeled after monolithic membrane valves and pumps that utilize a featureless polydimethylsiloxane (PDMS) membrane bonded between two etched glass wafers. The limited chemical compatibility of PDMS has necessitated research into alternative materials for microfluidic devices. Previous work has shown that spin-coated amorphous fluoropolymers and Teflon-fluoropolymer laminates can be fabricated and substituted for PDMS in monolithic membrane valves and pumps for space flight applications. However, the complex process for fabricating these spin-coated Teflon films and laminates may preclude their use in many research and manufacturing contexts. As an alternative, we show that commercially-available fluorinated ethylene-propylene (FEP) Teflon films can be used to fabricate chemically-inert monolithic membrane valves and pumps in glass microfluidic devices. The FEP Teflon valves and pumps presented here are simple to fabricate, function similarly to their PDMS counterparts, maintain their performance over extended use, and are resistant to virtually all chemicals. These structures should facilitate lab-on-a-chip research involving a vast array of chemistries that are incompatible with native PDMS microfluidic devices.

  5. Compliant topology optimization for planar passive flap micro valve.

    Science.gov (United States)

    Yoon, Gil Ho

    2014-10-01

    This paper reports the compliant topology optimization for planar passive flap micro valve considering fluid-structure interaction with a monolithic approach. Although flap valve type check valve is easy to manufacture and use for the applications for Bio/Nano/MEMS, its structural optimization has been seldom conducted so far. The size of the Bio/Nano/MEMS devices becomes smaller and the simple straight type micro valve structure is required to be optimized considering fluid speed. To address this optimization problem, the structural topology optimization scheme which designs optimal topologies is applied for a flap type check valve structure. To consider the coupling effects of fluid domain and structural domain, the monolithic finite element approach is employed. In the new analysis approach, solid domain is simulated by introducing the inverse permeability in the Navier-Stokes equation and the fluid stress filter in the linear elasticity equation. Also it is a new idea that fluid domain is simulated by finite elements with a weak Young's modulus in the linear elasticity equation. The mutual couplings between fluid and structure are considered by the introduction of the deformation tensor which is one of the basic concepts of the continuum mechanism. By distributing material properties inside a design domain for compliant flap, optimal flap structures can be constructed with different fluid speeds. By investigating the optimal layouts of several passive flap designs, we prove that the structural topology optimization can provide optimal layouts for Bio, Nano, and MEMS applications.

  6. Mitral Valve Prolapse in Pregnancy

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Abstract Mitral valve prolapse is a benign condition. Mitral regurgitation is only complicated in patients with severe mitral valve prolapse. Women with mitral valve prolapse in the absence of other cardiovascular disorders tolerate pregnancy well and do not develop remarkable cardiac complications. Nevertheless, serious complications of mitral valve prolapse, including arrhythmia, infective endocarditis and cerebral ischemic events, can be present in pregnancy. Debates remain with regard to the use of prophylactic antibiotics and β-blockers in the pregnant women with mitral valve prolapse. The prognosis of the pregnant patients might be closely related to the pathological and (or functional changes of the mitral valve. Non-myxomatous mitral valve prolapse poses no or little obstetric risks in terms of pregnancy, labor and neonatal complications; whereas myxomatous mitral valve prolapse is a major etiology of valvular heart disease in women of childbearing age. In the pregnant patients with mitral valve prolapse progressing into major complications, surgical interventions are considered. Medicinal treatment of such patients with β-blockers should be a concern for the fetal safety.

  7. Innovative Stemless Valve Eliminates Emissions

    Science.gov (United States)

    2008-01-01

    Big Horn Valve Inc. (BHVI), of Sheridan, Wyoming, won a series of SBIR and Small Business Technology Transfer (STTR) contracts with Kennedy Space Center and Marshall Space Flight Center to explore and develop a revolutionary valve technology. BHVI developed a low-mass, high-efficiency, leak-proof cryogenic valve using composites and exotic metals, and had no stem-actuator, few moving parts, with an overall cylindrical shape. The valve has been installed at a methane coal gas field, and future applications are expected to include in-flight refueling of military aircraft, high-volume gas delivery systems, petroleum refining, and in the nuclear industry.

  8. Whitey Gauge and Root Valves (VPS)

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel: Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the Vacuum Pumping and Helium System.

  9. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS...

  10. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    risk factors. METHODS AND RESULTS: Observational single-center study of 509 consecutive patients treated with a transcatheter implanted self-expandable aortic valve prosthesis (Medtronic CoreValve). We identified 18 patients diagnosed with TAVI-PVE during a median follow-up period of 1.4 years...

  11. Becker y Chapman, criminólogos internacionales: el interaccionismo simbólico en criminología visto en dos de sus representantes

    OpenAIRE

    Castillo Barrantes, Enrique

    2014-01-01

    Se parte de una presentación esquemática del interaccionismo en sociología general, siguiendo los lineamientos de una presentación hecha por Arnold M. Rose, para luego exponer las manifestaciones de dicha corriente en el campo criminológico, tal y como resulta de las principales obras de Howard S. Becker y Dennis Chapman.Tras pasar revistas sobre los temas más sobresalientes enfocados por ambos autores, se ponen en evidencia los aportes del interaccionismo y las nuevas posibilidades de aplica...

  12. Becker y Chapman, criminólogos internacionales: el interaccionismo simbólico en criminología visto en dos de sus representantes

    OpenAIRE

    Castillo Barrantes, Enrique

    2014-01-01

    Se parte de una presentación esquemática del interaccionismo en sociología general, siguiendo los lineamientos de una presentación hecha por Arnold M. Rose, para luego exponer las manifestaciones de dicha corriente en el campo criminológico, tal y como resulta de las principales obras de Howard S. Becker y Dennis Chapman.Tras pasar revistas sobre los temas más sobresalientes enfocados por ambos autores, se ponen en evidencia los aportes del interaccionismo y las nuevas posibilidades de aplica...

  13. Rapid laser prototyping of valves for microfluidic autonomous systems

    Science.gov (United States)

    Mohammed, M. I.; Abraham, E.; Y Desmulliez, M. P.

    2013-03-01

    Capillary forces in microfluidics provide a simple yet elegant means to direct liquids through flow channel networks. The ability to manipulate the flow in a truly automated manner has proven more problematic. The majority of valves require some form of flow control devices, which are manually, mechanically or electrically driven. Most demonstrated capillary systems have been manufactured by photolithography, which, despite its high precision and repeatability, can be labour intensive, requires a clean room environment and the use of fixed photomasks, limiting thereby the agility of the manufacturing process to readily examine alternative designs. In this paper, we describe a robust and rapid CO2 laser manufacturing process and demonstrate a range of capillary-driven microfluidic valve structures embedded within a microfluidic network. The manufacturing process described allows for advanced control and manipulation of fluids such that flow can be halted, triggered and delayed based on simple geometrical alterations to a given microchannel. The rapid prototyping methodology has been employed with PMMA substrates and a complete device has been created, ready for use, within 2-3 h. We believe that this agile manufacturing process can be applied to produce a range of complex autonomous fluidic platforms and allows subsequent designs to be rapidly explored.

  14. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  15. Manufacturing technology

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, J.A.; Floyd, H.L.; Goetsch, B.; Doran, L. [eds.

    1993-08-01

    This bulletin depicts current research on manufacturing technology at Sandia laboratories. An automated, adaptive process removes grit overspray from jet engine turbine blades. Advanced electronic ceramics are chemically prepared from solution for use in high- voltage varistors. Selective laser sintering automates wax casting pattern fabrication. Numerical modeling improves performance of photoresist stripper (simulation on Cray supercomputer reveals path to uniform plasma). And mathematical models help make dream of low- cost ceramic composites come true.

  16. Green Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Patten, John

    2013-12-31

    Green Manufacturing Initiative (GMI): The initiative provides a conduit between the university and industry to facilitate cooperative research programs of mutual interest to support green (sustainable) goals and efforts. In addition to the operational savings that greener practices can bring, emerging market demands and governmental regulations are making the move to sustainable manufacturing a necessity for success. The funding supports collaborative activities among universities such as the University of Michigan, Michigan State University and Purdue University and among 40 companies to enhance economic and workforce development and provide the potential of technology transfer. WMU participants in the GMI activities included 20 faculty, over 25 students and many staff from across the College of Engineering and Applied Sciences; the College of Arts and Sciences' departments of Chemistry, Physics, Biology and Geology; the College of Business; the Environmental Research Institute; and the Environmental Studies Program. Many outside organizations also contribute to the GMI's success, including Southwest Michigan First; The Right Place of Grand Rapids, MI; Michigan Department of Environmental Quality; the Michigan Department of Energy, Labor and Economic Growth; and the Michigan Manufacturers Technical Center.

  17. Surge-damping vacuum valve

    Science.gov (United States)

    Bullock, Jack C.; Kelly, Benjamin E.

    1980-01-01

    A valve having a mechanism for damping out flow surges in a vacuum system which utilizes a slotted spring-loaded disk positioned adjacent the valve's vacuum port. Under flow surge conditions, the differential pressure forces the disk into sealing engagement with the vacuum port, thereby restricting the flow path to the slots in the disk damping out the flow surge.

  18. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  19. Valve-"Health"-Monitoring System

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  20. Combination throttle and shutoff valve

    Science.gov (United States)

    Carriker, J. W.

    1972-01-01

    Combination of translating sleeve throttle valve and conventional poppet valve provides capability of shutting off flow completely by poppet and sleeve control of the rate of flow. Integration of the two concepts can be accomplished without difficulty and in a manner that requires a minimum of development.

  1. Variable gas leak rate valve

    Energy Technology Data Exchange (ETDEWEB)

    Eernisse, Errol P. (Albuquerque, NM); Peterson, Gary D. (Albuquerque, NM)

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  2. Fluid mechanics of artificial heart valves.

    Science.gov (United States)

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  3. MODELAGEM DO CRESCIMENTO DE CLONES DE Eucalyptus USANDO O MODELO DE CHAPMAN-RICHARDS COM DIFERENTES DISTRIBUIÇÕES SIMÉTRICAS DOS ERROS

    Directory of Open Access Journals (Sweden)

    Luiz Medeiros de Araujo Lima Filho

    2012-01-01

    Full Text Available The objective of this work was to estimate the height growth of Eucalyptus using the Chapman-Richards model considering for the errors the distributions normal, Student t (t and Cauchy. The data set came from one hybrid clone of Eucalyptus urophylla x Eucalyptus tereticornis x E. pellita (controlled pollination, of the Forestry Experimental Module in the Gypsum Pole of Araripe, established in 2002. Eighty-three trees were used which heights were measured in all trees for six and half years. The parameters of the Chapman- Richards model were obtained maximizing the log-likelihood function. For comparison of the adjustedmodels were used the criteria of Akaike Information Criterion (AIC and Bayesian (BIC and the mean absolute percentage error (MAPE. The model using the t distribution with 2 degrees of freedom (t2 had lower values of AIC and BIC and the model of Cauchy had lower value for MAPE. The results indicate that the model considering the t distribution for the errors presented best estimates of height growth of Eucalyptus hybrid clones in Gypsum Pole of Pernambuco.

  4. A study of trait anhedonia in non-clinical Chinese samples: evidence from the Chapman Scales for Physical and Social Anhedonia.

    Directory of Open Access Journals (Sweden)

    Raymond C K Chan

    Full Text Available BACKGROUND: Recent studies suggest that anhedonia, an inability to experience pleasure, can be measured as an enduring trait in non-clinical samples. In order to examine trait anhedonia in a non-clinical sample, we examined the properties of a range of widely used questionnaires capturing anhedonia. METHODS: 887 young adults were recruited from colleges. All of them were administered a set of checklists, including Chapman Scale for Social Anhedonia (CRSAS and the Chapman Scale for Physical Anhedonia Scale (CPAS, The Temporal Experience of Pleasure Scale(TEPS, and The Schizotypal Personality Questionnaire (SPQ. RESULTS: Males showed significantly higher level of physical (F = 5.09, p<0.001 and social (F = 4.38, p<0.005 anhedonia than females. As expected, individuals with schizotypal personality features also demonstrated significantly higher scores of physical (t = 3.81, p<0.001 and social (t = 7.33, p<0.001 trait anhedonia than individuals without SPD features, but no difference on self-report anticipatory and consummatory pleasure experience. CONCLUSIONS: Concerning the comparison on each item of physical and social anhedonia, the results indicated that individuals with SPD feature exhibited higher than individuals without SPD features on more items of social anhedonia than physical anhedonia scale. These preliminary findings suggested that trait anhedonia can be identified a non-clinical sample. Exploring the demographic and clinical correlates of trait anhedonia in the general population may provide clues to the pathogenesis of psychotic disorder.

  5. Robotic mitral valve surgery.

    Science.gov (United States)

    Kypson, Alan P; Nifong, L Wiley; Chitwood, W Randolph

    2003-12-01

    A renaissance in cardiac surgery has begun. The early clinical experience with computer-enhanced telemanipulation systems outlines the limitations of this approach despite some procedural success. Technologic advancements, such as the use of nitinol U-clips (Coalescent Surgical Inc., Sunnyvale, CA) instead of sutures requiring manual knot tying, have been shown to decrease operative times significantly. It is expected that with further refinements and development of adjunct technologies, the technique of computer-enhanced endoscopic cardiac surgery will evolve and may prove to be beneficial for many patients. Robotic technology has provided benefits to cardiac surgery. With improved optics and instrumentation, incisions are smaller. The ergometric movements and simulated three-dimensional optics project hand-eye coordination for the surgeon. The placement of the wristlike articulations at the end of the instruments moves the pivoting action to the plane of the mitral annulus. This improves dexterity in tight spaces and allows for ambidextrous suture placement. Sutures can be placed more accurately because of tremor filtration and high-resolution video magnification. Furthermore, the robotic system may have potential as an educational tool. In the near future, surgical vision and training systems might be able to model most surgical procedures through immersive technology. Thus, a "flight simulator" concept emerges where surgeons may be able to practice and perform the operation without a patient. Already, effective curricula for training teams in robotic surgery exist. Nevertheless, certain constraints continue to limit the advancement to a totally endoscopic computer-enhanced mitral valve operation. The current size of the instruments, intrathoracic instrument collisions, and extrathoracic "elbow" conflicts still can limit dexterity. When smaller instruments are developed, these restraints may be resolved. Furthermore, a working port incision is still required for

  6. Valve-related complications after mechanical heart valve implantation.

    Science.gov (United States)

    Misawa, Yoshio

    2015-10-01

    The number of heart valve surgeries is increasing, and 19,164 patients underwent heart valve surgery in Japan in 2011. The early mortality rate has remained stable for more than 10 years. Many patients now survive for many years, with a reported 10-year survival rate of at least 60 %. However, unfavorable complications can occur after valve surgery. Valve-related complications include thromboembolisms, bleeding complications and prosthetic valve endocarditis, followed by structural and nonstructural prosthetic valve dysfunctions. Our review of studies published after 2000 revealed that the rate of all valve-related complications was 0.7-3.5 % per patient-year. Thromboembolisms occur at a rate of approximately 1 % per patient-year, and bleeding complications occur at almost 0.5 % per patient-year. Thromboembolic and hemorrhagic events related to anticoagulant therapy should be considered during life-long follow-up. The occurrence rate of endocarditis reaches 0.5 % per patient-year, with a poor postoperative survival. Structural dysfunctions have been largely overcome, and the nonstructural dysfunction rate is 0.4-1.2 % per patient-year. The nonstructural dysfunctions induced by paravalvular leaks and pannus ingrowth are also issues that need to be resolved.

  7. Patents and heart valve surgery - II: tissue valves.

    Science.gov (United States)

    Cheema, Faisal H; Kossar, Alexander P; Rehman, Atiq; Younas, Fahad; Polvani, Gianluca

    2013-08-01

    Valvular heart disease affects millions of Americans yearly and currently requires surgical intervention to repair or replace the defective valves. Through a close-knit collaboration between physicians, scientists and biomedical engineers, a vast degree of research and development has been aimed towards the optimization of prosthetic heart valves. Although various methods have made fantastic strides in producing durable prostheses, the therapeutic efficacy of prosthetic valves is inherently limited by a dependency upon lifelong anticoagulant regimens for recipients - a difficult challenge for many in clinical setting. Thus, biological tissue valves have been developed to circumvent vascular and immunemediated complications by incorporating biological materials to mimic native valves while still maintaining a necessary level of structural integrity. Over the past decade, a multitude of patents pertaining to the refinement of designs as well as the advancement in methodologies and technologies associated with biological tissue valves have been issued. This review seeks to chronicle and characterize such patents in an effort to track the past, present, and future progress as well as project the trajectory of tissue valves in the years to come.

  8. LEAN Manufacturing

    DEFF Research Database (Denmark)

    Bilberg, Arne

      As part of an employment as Technology Architect at the company Linak in combination with research at the University of Southern Denmark, this paper will present results from a strategy process where Lean has been pointed out as being a very strategic element in the Linak Production System....... The mission with the strategy is to obtain competitive production in Denmark and in Western Europe based on the right combination of manufacturing principles, motivated and trained employees, level of automation, and cooperation with suppliers and customers worldwide. The strategy has resulted in technical......, organizational and management improvements in the company to what is named the Linak Production System.  ...

  9. LEAN Manufacturing

    DEFF Research Database (Denmark)

    Bilberg, Arne

      As part of an employment as Technology Architect at the company Linak in combination with research at the University of Southern Denmark, this paper will present results from a strategy process where Lean has been pointed out as being a very strategic element in the Linak Production System....... The mission with the strategy is to obtain competitive production in Denmark and in Western Europe based on the right combination of manufacturing principles, motivated and trained employees, level of automation, and cooperation with suppliers and customers worldwide. The strategy has resulted in technical...

  10. Self-Rupturing Hermetic Valve

    Science.gov (United States)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  11. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Inhalation and exhalation valves; check valves... PROTECTIVE DEVICES Supplied-Air Respirators § 84.137 Inhalation and exhalation valves; check valves; minimum requirements. (a) Inhalation and exhalation valves shall be provided where necessary and protected...

  12. Rapid Growth of China Petroleum Machinery Manufacturing (continued)

    Institute of Scientific and Technical Information of China (English)

    Huang Zhiqian; Sun Zuchen; Wang Keyu

    1996-01-01

    @@ Technology for petroleum machinery design and manufacturing upgraded remarkably The basic research on rock bit. drilling pump. pump valve, piston, flooding pumps, derrick, shale shaker.hydraulic blowout preventer, torque converter, pumping unit. sucker rod. submersible pump. fracturing pump centrifugal pump. pneumatic parts, geophone and acquisition station has reached the advanced international level.

  13. 49 CFR 195.116 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 195.116 Section 195.116 Transportation... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to...

  14. 14 CFR 125.133 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 125.133 Section 125.133....133 Fuel valves. Each fuel valve must— (a) Comply with § 125.155; (b) Have positive stops or suitable... operation or from accelerated flight conditions are not transmitted to the lines connected to the valve....

  15. 49 CFR 192.145 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 192.145 Section 192.145 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.145 Valves. (a) Except for cast iron and plastic valves, each valve must meet the minimum requirements of API...

  16. 14 CFR 125.137 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  17. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  18. Proportional valve with a piezoelectric actuator

    Science.gov (United States)

    Laski, Pawel Andrzej

    2016-11-01

    The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  19. Proportional valve with a piezoelectric actuator

    Directory of Open Access Journals (Sweden)

    Laski Pawel Andrzej

    2017-01-01

    Full Text Available The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  20. Double prosthetic aortic valve. Case report.

    Science.gov (United States)

    Liddicoat, J E; Bekassy, S M; De Bakey, M E

    1975-05-01

    A 55-year-old man underwent insection of a Hufnagel valve into his descending thoracic aorta for aortic valve insufficiency 18 years ago. He remained asymptomatic for 16 years. Because of progressive left ventricular failure his incompetent aortic valve was replaced with a De Bakey carbon ball aortic valve prosthesis 2 years later. Currently, 21 months after the operation, he is doing well with two aortic valves. Review of the literature suggests that he is the first patient reported with two aortic valves functioning concomitantly and one of the longest surviving patients with a Hufnagel valve.

  1. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  2. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  3. Human tissue valves in aortic position: determinants of reoperation and valve regurgitation

    NARCIS (Netherlands)

    T.P. Willems (Tineke); E.W. Steyerberg (Ewout); V.E. Kleyburg-Linkers; E. Bos (Egbert); L.A. van Herwerden (Lex); J.R.T.C. Roelandt (Jos); J.J.M. Takkenberg (Hanneke)

    2001-01-01

    textabstractBACKGROUND: Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve

  4. Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation

    NARCIS (Netherlands)

    J.P.A. Puvimanasinghe (John); M.B. Edwards; M.J.C. Eijkemans (René); E.W. Steyerberg (Ewout); L.A. van Herwerden (Lex); K.M. Taylor; G.L. Grunkemeier (Gary); J.D.F. Habbema (Dik); A.J.J.C. Bogers (Ad); J.J.M. Takkenberg (Hanneke)

    2004-01-01

    textabstractBACKGROUND: Mechanical valves and bioprostheses are widely used for aortic valve replacement. Though previous randomised studies indicate that there is no important difference in outcome after implantation with either type of valve, knowledge of outcomes after aortic va

  5. An editorial view on the reporting of results in heart valve bioprostheses.

    Science.gov (United States)

    Del Campo, C

    1986-01-01

    Heart valve bioprostheses are most commonly analyzed as a group rather than individualized. Mechanical valves are usually referred to by specific name and manufacturer, while bioprostheses are pooled together as "tissue valves". Each specific bioprosthesis has its own structural characteristics and therefore a different level of performance and durability. Most large centers have an adequate number of these implants and a follow-up long enough to warrant separate analysis of each valve type. This review analyzes the differences among the most commonly used bioprostheses and reaffirms the reasons for their separate analysis. Authors, reviewers and editors must standardize their criteria to prevent this problem from recurring or escalating. New bioprostheses are now being released and unless we simplify their evaluation our questions will remain unanswered.

  6. Simpler valve for reciprocating engines

    Science.gov (United States)

    Akkerman, J. W.

    1978-01-01

    Simpler design eliminating camshafts, cams, and mechanical springs should improve reliability of hydrazine powered reciprocating engines. Valve is expected to improve efficiency, and reduce weight of engines in range up to 50 horsepower.

  7. Titanium in engine valve systems

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J.E.; Sherman, A.M.; Bapna, M.R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a two-to-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance.

  8. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  9. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... a heart attack or injury to the heart. Rheumatic Fever Untreated strep throat or other infections with strep bacteria that progress to rheumatic fever can cause heart valve disease. When the body ...

  10. CONGENITAL QUADRICUSPID AORTIC-VALVE

    NARCIS (Netherlands)

    BROUWER, MHJ; DEGRAAF, JJ; EBELS, T

    1993-01-01

    Two patients with a quadricuspid aortic valve are described, one of them with concomitant juxtaposed coronary orifices facing the right hand facing sinus. The etiology and incidence of this congenital anomaly will be discussed.

  11. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy....... The 30-day mortality rate for the 98 patients was zero, although 14 of the 98 mini-sternotomies had to be converted to complete sternotomies intraoperatively due to technical problems. Such conversion doubled the operative time over that of the planned full sternotomies. In the group of patients whose...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  12. The spin-valve transistor

    NARCIS (Netherlands)

    Monsma, Douwe Johannes

    1998-01-01

    High density magnetic recording, magnetic random access memories, displacement and current detection, contactless switching and electronic compass applications all require magnetic field sensors with unprecedented sensitivity. The spin-valve effect (giant magnetoresistance) found in 1988 in magnetic

  13. Conceptual design of a compact absolute valve for the ITER neutral beam injectors

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Chris [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom)], E-mail: chris.m.jones@jet.uk; Waldon, Chris; Martin, David; Watson, Mike [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Sonderegger, Kurt; Lenherr, Bruno [VAT Vakuumventile AG, CH-9469 Haag (Switzerland); Andrews, Ian; Mansbridge, Simon [VAT Vacuum Products Ltd., Edmund House, Rugby Road, Leamington Spa, Warwickshire CV32 6EL (United Kingdom)

    2009-06-15

    The reference design for the ITER neutral beam injectors incorporated a fast shutter to limit tritium migration to the injector vacuum enclosures. In 2005, a need for an 'absolute' isolation valve was identified to facilitate injector maintenance procedures and protect the system from an in-vessel ingress of coolant event (ICE). An outline concept for an all-metal seal valve was developed during 2006, in close cooperation with the Swiss valve manufacturer VAT. During the following year, it became apparent that the length of beamline available for the valve was significantly less than originally envisaged, resulting in a radical revision of the design concept. A casing length of 760 mm has been achieved by means of major changes to the casing structure, plate dimensions, pendulum mechanism and seal actuators. A concept for a seal protection system has been developed to prevent beam line contamination reaching the valve components and to protect the valve plate from surface heating by plasma radiation. The new design concept has been extensively validated by analysis, including a whole-system FE model of the valve.

  14. 57. Aortic valve replacement with sutureless valve and mitral valve repair in patient with infected aortic homograft

    Directory of Open Access Journals (Sweden)

    A. attia

    2016-07-01

    Full Text Available The approach of implanting aortic sutureless valve inside the calcific homograft is suitable in redo surgery especially if associated with mitral valve surgery. Aortic valve replacement in patients who have undergone previous aortic root replacement with an aortic homograft remains a technical challenge because of homograft degeneration and the need for a redo Bentall operation. We report a case of redo aortic valve replacement (valve in valve with a sutureless valve and mitral valve repair by miniband annuloplasty in a female patient aged 64 years old who underwent aortic valve replacement with homograft 14 years ago and presented by sever aortic valve regurge and sever mitral valve regurge because of infective endocarditis. This technique allows rapid aortic valve replacement in a heavily calcified aortic root. It also avoids aortic valve size affection after mitral valve repair by ordinary methods especially in patients with small aortic annulus. This technique is particularly suitable in redo procedures for homograft degeneration, it avoids performing a redo Bentall operation with its known problems as well as to avoid patient prosthesis mismatch.

  15. Normal solution and transport coefficients to the Enskog-Landau kinetic equation for a two-component system of charged hard spheres The Chapman-Enskog method

    CERN Document Server

    Kobryn, A E; Tokarchuk, M V

    1999-01-01

    An Enskog-Landau kinetic equation for a many-component system of charged hard spheres is proposed. It has been obtained from the Liouville equation with modified boundary conditions by the method of nonequilibrium statistical operator. On the basis of this equation the normal solutions and transport coefficients such as bulk kappa and shear eta viscosities, thermal conductivity lambda, mutual diffusion D^{\\alpha\\beta} and thermal diffusion D_T^\\alpha have been obtained for a binary mixture in the first approximation using the Chapman-Enskog method. Numerical calculations of all transport coefficients for mixtures Ar-Kr, Ar-Xe, Kr-Xe with different concentrations of compounds have been evaluated for the cases of absence and presence of long-range Coulomb interactions. The results are compared with those obtained from other theories and experiment.

  16. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  17. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    Background: Optimal transcatheter heart valve (THV) sizing is crucial to optimize procedural outcomes. Larger THV oversizing is shown to decrease paravalvular leakage post transcatheter aortic valve replacement but its role in Valve in Valve implantation (ViV) is not well established. Methods...... group received a larger THV (25.5± 1.4 mm vs. 23.3 ± 1.0 mm, pimplantation, the oversized group achieved a larger EOA (1.54±0.4cm2 vs. 1.37± 0.5cm2, p...V implantation was associated with favorable post-implant EOA and gradient but a higher risk of aortic insufficiency and THV re-intervention. Further exploration within various THV and surgical valve types at different degree of THV oversizing is planned....

  18. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  19. Additive manufacturing – a sustainable manufacturing route

    Directory of Open Access Journals (Sweden)

    Frăţilă Domniţa

    2017-01-01

    Full Text Available Additive Manufacturing (AM technologies allow developing and manufacturing very complex shaped parts and functional products with a high level of customization, being a great alternative to Traditional Manufacturing (TM methods like injection molding, die-casting or machining. Due to the importance of cleaner production in the field of manufacturing processes, sustainability of AM processes needs to be assessed in order to make easier its acceptance and implementation in the industry. Furthermore, the manufacturers can improve their competitiveness and profitability by considering the ecological aspects during the manufacturing step of a product. This paper gives a survey on sustainability issues related to AM.

  20. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  1. Additive manufacturing – a sustainable manufacturing route

    OpenAIRE

    Frăţilă Domniţa; Rotaru Horaţiu

    2017-01-01

    Additive Manufacturing (AM) technologies allow developing and manufacturing very complex shaped parts and functional products with a high level of customization, being a great alternative to Traditional Manufacturing (TM) methods like injection molding, die-casting or machining. Due to the importance of cleaner production in the field of manufacturing processes, sustainability of AM processes needs to be assessed in order to make easier its acceptance and implementation in the industry. Furth...

  2. Additive manufacturing – a sustainable manufacturing route

    OpenAIRE

    Frăţilă Domniţa; Rotaru Horaţiu

    2017-01-01

    Additive Manufacturing (AM) technologies allow developing and manufacturing very complex shaped parts and functional products with a high level of customization, being a great alternative to Traditional Manufacturing (TM) methods like injection molding, die-casting or machining. Due to the importance of cleaner production in the field of manufacturing processes, sustainability of AM processes needs to be assessed in order to make easier its acceptance and implementation in the industry. Furth...

  3. Analysis of Complex Valve and Feed Systems

    Science.gov (United States)

    Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Cavallo, Peter; Dash, Sanford

    2007-01-01

    A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.

  4. Large Scale Magnetostrictive Valve Actuator

    Science.gov (United States)

    Richard, James A.; Holleman, Elizabeth; Eddleman, David

    2008-01-01

    Marshall Space Flight Center's Valves, Actuators and Ducts Design and Development Branch developed a large scale magnetostrictive valve actuator. The potential advantages of this technology are faster, more efficient valve actuators that consume less power and provide precise position control and deliver higher flow rates than conventional solenoid valves. Magnetostrictive materials change dimensions when a magnetic field is applied; this property is referred to as magnetostriction. Magnetostriction is caused by the alignment of the magnetic domains in the material s crystalline structure and the applied magnetic field lines. Typically, the material changes shape by elongating in the axial direction and constricting in the radial direction, resulting in no net change in volume. All hardware and testing is complete. This paper will discuss: the potential applications of the technology; overview of the as built actuator design; discuss problems that were uncovered during the development testing; review test data and evaluate weaknesses of the design; and discuss areas for improvement for future work. This actuator holds promises of a low power, high load, proportionally controlled actuator for valves requiring 440 to 1500 newtons load.

  5. Desktop Manufacturing Technologies.

    Science.gov (United States)

    Snyder, Mark

    1991-01-01

    Desktop manufacturing is the use of data from a computer-assisted design system to construct actual models of an object. Emerging processes are stereolithography, laser sintering, ballistic particle manufacturing, laminated object manufacturing, and photochemical machining. (SK)

  6. Tribology in Manufacturing Technology

    CERN Document Server

    2013-01-01

    The present book aims to provide research advances on tribology in manufacturing technology for modern industry. This book can be used as a research book for final undergraduate engineering course (for example, mechanical, manufacturing, materials, etc) or as a subject on manufacturing at the postgraduate level. Also, this book can serve as a useful reference for academics, manufacturing and tribology researchers, mechanical, mechanical, manufacturing and materials engineers, professionals in related industries with manufacturing and tribology.

  7. 49 CFR 179.400-19 - Valves and gages.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Valves and gages. 179.400-19 Section 179.400-19...-19 Valves and gages. (a) Valves. Manually operated shut-off valves and control valves must be... liquid flow rates. All valves must be made from approved materials compatible with the lading and...

  8. Additive Manufacturing for Affordable Rocket Engines

    Science.gov (United States)

    West, Brian; Robertson, Elizabeth; Osborne, Robin; Calvert, Marty

    2016-01-01

    Additive manufacturing (also known as 3D printing) technology has the potential to drastically reduce costs and lead times associated with the development of complex liquid rocket engine systems. NASA is using 3D printing to manufacture rocket engine components including augmented spark igniters, injectors, turbopumps, and valves. NASA is advancing the process to certify these components for flight. Success Story: MSFC has been developing rocket 3D-printing technology using the Selective Laser Melting (SLM) process. Over the last several years, NASA has built and tested several injectors and combustion chambers. Recently, MSFC has 3D printed an augmented spark igniter for potential use the RS-25 engines that will be used on the Space Launch System. The new design is expected to reduce the cost of the igniter by a factor of four. MSFC has also 3D printed and tested a liquid hydrogen turbopump for potential use on an Upper Stage Engine. Additive manufacturing of the turbopump resulted in a 45% part count reduction. To understanding how the 3D printed parts perform and to certify them for flight, MSFC built a breadboard liquid rocket engine using additive manufactured components including injectors, turbomachinery, and valves. The liquid rocket engine was tested seven times in 2016 using liquid oxygen and liquid hydrogen. In addition to exposing the hardware to harsh environments, engineers learned to design for the new manufacturing technique, taking advantage of its capabilities and gaining awareness of its limitations. Benefit: The 3D-printing technology promises reduced cost and schedule for rocket engines. Cost is a function of complexity, and the most complicated features provide the largest opportunities for cost reductions. This is especially true where brazes or welds can be eliminated. The drastic reduction in part count achievable with 3D printing creates a waterfall effect that reduces the number of processes and drawings, decreases the amount of touch

  9. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj;

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  10. Aortic valve replacement with the Nicks annulus enlargement procedure 12 years after mitral valve replacement.

    Science.gov (United States)

    Kazama, S; Kurata, A; Yamashita, Y

    1999-10-01

    An aortic valve replacement was successfully performed employing the Nicks annulus enlargement procedure in a case of aortic valve stenosis with small annulus 12 years after mitral valve replacement. Previous mitral valve replacement does not preclude feasibility of the Nicks procedure.

  11. Transapical transcatheter valve-in-valve replacement for deteriorated mitral valve bioprosthesis without radio-opaque indicators: the "invisible" mitral valve bioprosthesis.

    Science.gov (United States)

    Rossi, Marco Luciano; Barbaro, Cristina; Pagnotta, Paolo; Cappai, Antioco; Ornaghi, Diego; Belli, Guido; Presbitero, Patrizia

    2015-02-01

    In view of the high number of bioprosthetic valves implanted during the past 30 years, an increasing number of patients are coming to medical attention because of degenerated bioprostheses. Transcatheter aortic valve-in-valve implantation has been described as a less invasive alternative to re-operation to treat severe structural valve deterioration. As far as degenerated mitral valve bioprostheses are concerned, transcatheter transapical mitral valve-in-valve replacement (TMVR) has been less commonly performed, but may also become a viable alternative to re-do replacement surgery. We describe treatment of a degenerated bioprosthetic mitral valve, characterised by complete absence of any radio-opaque landmarks making the TMVR procedure very challenging.

  12. Percutaneous heart valves; past, present and future.

    Science.gov (United States)

    Rozeik, M M; Wheatley, D J; Gourlay, T

    2014-09-01

    Percutaneous heart valves provide a promising future for patients refused surgery on the grounds of significant technical challenges or high risk for complications. Since the first human intervention more than 10 years ago, over 50 different types of valves have been developed. The CoreValve and Edwards SAPIEN valves have both experienced clinical trials and the latter has gained FDA approval for implantation in patients considered inoperable. Current complications, such as major vascular bleeding and stroke, prevent these valves from being commonly deployed in patients considered operable in conventional surgery. This review focuses on the past and present achievements of these valves and highlights the design considerations required to progress development further. It is envisaged that, with continued improvement in valve design and with increased clinical and engineering experience, percutaneous heart valve replacement may one day be a viable option for lower-risk operable patients.

  13. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  14. Propellant isolation shutoff valve program

    Science.gov (United States)

    Merritt, F. L.

    1973-01-01

    An analysis and design effort directed to advancing the state-of-the-art of space storable isolation valves for control of flow of the propellants liquid fluorine/hydrazine and Flox/monomethylhydrazine is discussed. Emphasis is on achieving zero liquid leakage and capability of withstanding missions up to 10 years in interplanetary space. Included is a study of all-metal poppet sealing theory, an evaluation of candidate seal configurations, a valve actuator trade-off study and design description of a pneumo-thermally actuated soft metal poppet seal valve. The concepts and analysis leading to the soft seal approach are documented. A theoretical evaluation of seal leakage versus seal loading, related finishes and yield strengths of various materials is provided. Application of a confined soft aluminum seal loaded to 2 to 3 times yield strength is recommended. Use of either an electro-mechanical or pneumatic actuator appears to be feasible for the application.

  15. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  16. 2D SIMPLIFIED SERVO VALVE

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A novel pilot stage valve called simplified 2D valve, which utilizes both rotary and linear motions of a single spool, is presented.The rotary motion of the spool incorporating hydraulic resistance bridge, formed by a damper groove and a crescent overlap opening, is utilized as pilot to actuate linear motion of the spool.A criterion for stability is derived from the linear analysis of the valve.Special experiments are designed to acquire the mechanical stiffness, the pilot leakage and the step response.It is shown that the sectional size of the spiral groove affects the dynamic response and the stiffness contradictorily and is also very sensitive to the pilot leakage.Therefore, it is necessary to establish a balance between the static and dynamic characteristics in deciding the structural parameters.Nevertheless, it is possible to sustain the dynamic response at a fairly high level, while keeping the leakage of the pilot stage at an acceptable level.

  17. Intelligente valve monitor for on/off control valves in process engineering; Intelligenter Grenzsignalgeber fuer Auf/Zu-Armaturen in der Prozesstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Karte, Thomas; Kiesbauer, Joerg; Schaertner, Karl-Bernd [SAMSON AG, Frankfurt (Germany)

    2009-07-01

    In the article entitled ''Smart and Reliable Whether On or Off - Valve Automation Trends'' [1] of December 2007, trends in the automation of On/Off control valves were illustrated. To meet the general demand for higher plant availability, superior reliability and lower costs, both the quality and quantity of automation systems used in this field continue to advance. In this article, an actual technical solution is described. For the first time, a manufacturer succeeded in building a microcomputerbased device that is exclusively supplied with a signal according to IEC 60947-5-6 (NAMUR signal) using a two-wire supply. As a result, a new generation of devices offering new opportunities can replace the classical solenoid valves and limit switches without requiring the cabling or signal levels to be changed. Plant operators additionally benefit from enhanced functions (e.g. self-tuning and diagnostics) that, until now, only positioners provided. (orig.)

  18. Transapical Mitral Valve-in-Valve Replacement in Patient With Previous Complex Sternal Reconstruction.

    Science.gov (United States)

    Hynes, Conor F; Fatemi, Omid; Sharma, Aditya C; Nagy, Christian D; Trachiotis, Gregory D

    2016-01-01

    We present a complex case of a transapical redo mitral valve-in-valve replacement. Repeat mitral valve replacement was indicated for severe symptomatic bioprosthetic stenosis. In addition to the patient's numerous comorbidities that included diabetes, hepatic cirrhosis, ischemic cardiomyopathy, and atrial flutter, he had undergone a previous open mitral valve replacement that was complicated by sternal dehiscence requiring extensive chest wall reconstruction. Transapical approach was performed through left minithoracotomy incision with balloon-expandable valve. Transapical valve-in-valve replacement of a stenotic mitral bioprosthesis is a viable solution in a patient with previous complex chest wall reconstruction and multiple comorbidities.

  19. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves.

  20. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  1. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj;

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  2. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  3. Advantages with small control valves

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Gunnar

    2008-09-15

    Between 1995 and 2005, the Swedish District Heating Association carried out several research projects concerning small dimensions on control valves. This lecture aims at giving a summary of these findings which, if they are carried out, have a great impact on the district heating system. The outcome is advantages on both the production side and the customer side. Some of the project's conclusions are as follows: 1. The simulations show that the consequences of temperature disturbances can be reduced when applying smaller control valves, especially at low outdoor temperatures (-5 deg C). 2. The consequences of flow disturbances (pump stop) are not depending on the outdoor temperature (heat demand), but results over the whole year in reduced maximum flow during the process of operation recovery. With adequately reduced valve size, the resulting maximum flow at restart can be approximately reduced to the half, leading in reduced need of pumping peak power. 3. Similarly, the maximum peak power taken from the net at net recovery will be reduced, however, this effect is not as strong as that for flow. 4. Generally, we have found clear indications for that the adjustment of the K{sub vs}-values of control valves in substations should follow a certain logical order of priority. An important factor is the location of substations in respect to the production plant and to the pressure control points in the network. Another important factor is the absolute K{sub vs}-value of the over sizing, i.e. the difference of the actual installed valve and the targeted valve size. 5. Smaller size of control valves means also an improvement of the everyday operation of the district heating net, especially in the case when flow and power peaks are expected to occur. Examples for that could be the morning peaks with increase heat and hot water demands, or such events when the air temperature is decreasing very fast because of weather phenomena. Smaller control valves will smear out the

  4. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  5. Surface spin-valve effect.

    Science.gov (United States)

    Yanson, I K; Naidyuk, Yu G; Fisun, V V; Konovalenko, A; Balkashin, O P; Triputen, L Yu; Korenivski, V

    2007-04-01

    We report an observation of spin-valve-like hysteresis within a few atomic layers at a ferromagnetic interface. We use phonon spectroscopy of nanometer-sized point contacts as an in situ probe to study the mechanism of the effect. Distinctive energy phonon peaks for contacts with dissimilar nonmagnetic outer electrodes allow localizing the observed spin switching to the top or bottom interfaces for nanometer thin ferromagnetic layers. The mechanism consistent with our data is energetically distinct atomically thin surface spin layers that can form current- or field-driven surface spin-valves within a single ferromagnetic film.

  6. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-11

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHa System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHa supply line.

  7. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  8. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  9. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  10. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  11. 14 CFR 27.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 27.995 Section 27.995... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.995 Fuel valves. (a) There must be a positive, quick-acting valve to shut off fuel to each engine individually. (b) The control...

  12. 14 CFR 29.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 29.995 Section 29.995... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.995 Fuel valves. In addition to meeting the requirements of § 29.1189, each fuel valve must— (a) (b) Be supported so that no...

  13. 14 CFR 25.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 25.995 Section 25.995... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.995 Fuel valves. In addition to the requirements of § 25.1189 for shutoff means, each fuel valve must— (a) (b) Be supported...

  14. 14 CFR 29.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 29.1025 Section 29.1025... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1025 Oil valves. (a) Each oil shutoff.... (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  15. 14 CFR 25.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 25.1025 Section 25.1025... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1025 Oil valves. (a) Each oil shutoff... feathering. (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  16. 49 CFR 195.258 - Valves: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: General. 195.258 Section 195.258... PIPELINE Construction § 195.258 Valves: General. (a) Each valve must be installed in a location that is accessible to authorized employees and that is protected from damage or tampering. (b) Each submerged...

  17. 14 CFR 121.239 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil valve must— (1) Comply with § 121.257; (2) Have positive stops or suitable index provisions in the...

  18. 14 CFR 121.235 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 121.235 Section 121.235..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel valve must— (a) Comply with § 121.257; (b) Have positive stops or suitable index provisions in the...

  19. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ....109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a combined capacity to prevent an accumulation of pressure of more than five pounds per square inch above the... ends of the safety valve discharge lines shall be located or protected so that discharged steam...

  20. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  1. Flow and plate motion in compressor valves

    NARCIS (Netherlands)

    Habing, Reinder André

    2005-01-01

    The Basic Valve Theory is based on steady ow characteristics. Therefore unsteady ow conditions in the model valve have been considered in order to assess effects of unsteadiness on the performance of the Basic Valve Theory. The instantaneous gas force was predicted rather accurately by the theory. H

  2. Staphylococcus saprophyticus causing native valve endocarditis.

    Science.gov (United States)

    Garduño, Eugenio; Márquez, Irene; Beteta, Alicia; Said, Ibrahim; Blanco, Javier; Pineda, Tomás

    2005-01-01

    Coagulase negative staphylococci are a rare cause of native valve endocarditis. Staphylococcus saprophyticus is a coagulase-negative Staphylococcus infrequently reported as a human pathogen, and most of the cases reported are urinary tract infections. We describe a case of native valve endocarditis attributed to this organism. The patient needed valve replacement due to heart failure.

  3. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  4. The presence of fructosamine in human aortic valves is associated with valve stiffness.

    Science.gov (United States)

    Kishabongo, Antoine S; Katchunga, Philippe; Cikomola, Justin C; De Somer, Filip M; De Buyzere, Marc L; Speeckaert, Marijn M; Delanghe, Joris R

    2016-09-01

    Human heart valves are prone to glycation, a fundamental process of ageing. The aim of this study was to establish the relationship between fructosamine formation and the mechanical properties of human aortic valves. 67 patients (age: 76±8 years) diagnosed with an aortic valve stenosis, who underwent an aortic valve replacement were enrolled. Fructosamine and calcium concentrations in aortic valves were determined. Using a transthoracic Doppler echocardiography, aortic valve orifice area and transvalvular pressure gradients were measured. In a subgroup of 32 patients, the aortic valve orifice area was sufficient to carry out mechanical testing on a LFPlus Universal material tester. An in vitro removal of fructosamine of the valve was initiated using ATP-dependent fructosamine 3-kinase (FN3K). A significant correlation was found between the aortic valve fructosamine concentration and the calculated aortic valve orifice area: Y (aortic valve orifice area, mm(2))=1.050-0.228X (aortic valve fructosamine concentration, µmol/g valve) (r=-0.38). A significantly higher calcium concentration was measured in the aortic valves of diabetics in comparison with those of non-diabetics. A multiple regression analysis revealed that the presence of diabetes mellitus and aortic valve fructosamine concentration were the main predictors of the extensibility of the aortic valves. In the in vitro deglycation study, a significant lower aortic valve fructosamine concentration was detected after treatment with FN3K. This resulted in an increased flexibility of the aortic valves. Although no direct causativeness is proven with the presented results, which just show an association between fructosamine, the effect of FN3K and aortic valve stiffness, the present study points for the first time towards a possible additional role of the Amadori products in the biomechanical properties of ageing aortic valves. Published by the BMJ Publishing Group Limited. For permission to use (where not

  5. Pressure relief valve/safety relief valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Murray, W.A.; Hamm, E.R.; Barber, J.R.

    1994-02-01

    Pressure vessels and piping systems are protected form overpressurization by pressure relief valves. These safety features are required to be tested-inspected on some periodic basis and, in most cases witnessed by a third party inspector. As a result nonconformances found by third parties Westinghouse Hanford Company initiated a task team to develop a pressure safety program. This paper reveals their findings.

  6. Sizing of safety valves for multi-phase flow - ISO 4126 and state of knowledge

    CERN Document Server

    CERN. Geneva

    2016-01-01

    In Industry sizing of safety valves for two-phase flow is still a challenge. Hazard analysis to identify the worst case scenaio, mechanical and thermodynamic non-equilibrium conditions to estimate the mass flow rate and multiple critical flow conditions are among others topics that may lead to differences in sizing a safety valve of up to 1 order of magnitude. There are more than 20 models available to size a safety valve. All of them are based on ideal nozzle flow and corrected by an experimentally determined discharge coefficient. API 520 recommend a homogeneous equilibrium flow model to conservatively estimate the mass flow rate to be discharged. Whereas ISO 4126-10 includes a method for condidering boiling delay and slip effects, which lead to much lesser valve sizes. The discharge coefficient for two-phase flow is part of a model and will not be measured. Valve manufacturer certify only the capacitance and valve functioning under ideal laboratory conditions without inlet and outlet piping. Unfortunat...

  7. Rack And Pinion Mechanism for Continuous Variable Valve Timing of IC Engines

    Directory of Open Access Journals (Sweden)

    Dhruv Chawda

    2014-11-01

    Full Text Available The valve timing is a very closely studied event and effects the performance of an IC Engine greatly with respect to the Brake Power Produced, Volumetric Efficiency and Emissions etc. The valve event if varied and experimented with, can result in higher efficiencies and overall improved performance of the Engine. Hence, various researchers have attempted to temper with the valve timing and thus many Variable Valve Timing systems have been proposed till date with many of them being implemented by various manufacturers. However, on reviewing the presently employed systems, the lack of existence of a single system capable of independently altering both the timing and the lift of the valves was recognized. Thus, a single system capable of achieving the above was thought of and designed. A rack and pinion mechanism powered by a programmed servo motor mounted vertically seemed most practical in achieving this within the size and space constraints. A single cylinder diesel Engine was simulated with „Lotus Engine Simulation‟ software to derive the optimum valve angles and lifts for a range of the Engine operating speed and the system was accordingly programmed and designed to achieve them. The system was designed in „Creo‟ software and analysed correspondingly in „Ansys‟ software and then finally assembled on a Diesel Engine in the lab.

  8. Overvoltage and Insulation Coordination for Valve Winding of ±800 kV UHVDC Converter Transformer

    Institute of Scientific and Technical Information of China (English)

    ZHOU Peihong; DAI Ming; HE Huiwen

    2012-01-01

    The determination of insulation levels for valve windings of ± 800 kV UHVDC converter transformers is a key problem for designing and manufacturing of the converter transformers. Based on the Yunnan-Guangdong ± 800 kV DC power transmission project, the arrester parameters for direct or indirect protection of the valve windings are selected. The EMTDC program is used to calculate several faults, which determine mainly the specified insulation levels of valve winding for temporary, switching and lightning impulses, and the overvoltage generating mechanisms according to these faults are analyzed. The polarity reversal overvohage and the related reversal time at valve windings caused by the emergency switch off sequence of converters (ESOF) are calculated to confirm the necessity of DC voltage polarity reversal type tests of valve windings. The reasonability of the three insulation coordination methods, which determine converter transformers' switching impulse insulation levels, is analyzed. Method 1 is concluded to be more reasonable, and it is used to determine the switching impulse withstand voltage (SIWV) from the switching overvohage calculation results. The lightning impulse withstand voltage (LIWV) of valve windings can be determined by the ratio between LIWV and SIWV. The principle of the ratio selection is presented, and it is used to determine the LIWV. The operation experience of Yunnan-Guangdong ±800 kV DC project has proven that the presented insulation levels is appropriate.

  9. MODELING, VALIDATION AND OPTIMAL DESIGN OF THE CLAMPING FORCE CONTROL VALVE USED IN CONTINUOUSLY VARIABLE TRANSMISSION

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yunshan; LIU Jin'gang; CAI Yuanchun; ZOU Naiwei

    2008-01-01

    Associated dynamic performance of the clamping force control valve used in continuously variable transmission (CVT) is optimized. Firstly, the structure and working principle of the valve are analyzed, and then a dynamic model is set up by means of mechanism analysis. For the purpose of checking the validity of the modeling method, a prototype workpiece of the valve is manufactured for comparison test, and its simulation result follows the experimental result quite well. An associated performance index is founded considering the response time, overshoot and saving energy, and five structural parameters are selected to adjust for deriving the optimal associated performance index. The optimization problem is solved by the genetic algorithm (GA) with necessary constraints. Finally, the properties of the optimized valve are compared with those of the prototype workpiece, and the results prove that the dynamic performance indexes of the optimized valve are much better than those of the prototype workpiece.Key words: Dynamic modeling Optimal design Genetic algorithm Clamping force control valve Continuously variable transmission (CVT)

  10. Aortic valve stenosis after previous coronary bypass: Transcatheter valve implantation or aortic valve replacement?

    Directory of Open Access Journals (Sweden)

    Jegaden Olivier

    2012-05-01

    Full Text Available Abstract We report a prospective comparison between transcatheter valve implantation (TAVI, n = 13 and surgical aortic valve replacement (AVR, n = 10 in patients with severe aortic valve stenosis and previous coronary bypass surgery (CABG. All patients had at least bilateral patent internal thoracic arteries bypass without indication of repeat revascularization. After a similar post-procedure outcome, despite one early death in TAVI group, the 1-year survival was 100% in surgical group and in transfemoral TAVI group, and 73% in transapical TAVI group. When previous CABG is the lone surgical risk factor, indications for a TAVI procedure have to be cautious, specially if transfemoral approach is not possible.

  11. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  12. Manufacturing network evolution

    DEFF Research Database (Denmark)

    Yang, Cheng; Farooq, Sami; Johansen, John

    2011-01-01

    Purpose – This paper examines the effect of changes at the manufacturing plant level on other plants in the manufacturing network and also investigates the role of manufacturing plants on the evolution of a manufacturing network. Design/methodology/approach –The research questions are developed......, the complex phenomenon of a manufacturing network evolution is observed by combining the analysis of a manufacturing plant and network level. The historical trajectories of manufacturing networks that are presented in the case studies are examined in order to understand and determine the future shape...

  13. Influence of St. Jude medical valve in patients with aortic stenosis and small aortic annulus on cardiac function and late survival result.

    Science.gov (United States)

    Natsuaki, Masafumi; Itoh, Tsuyoshi; Okazaki, Yukio; Takarabe, Kyoumi; Furukawa, Koujirou; Rikitake, Kazuhisa; Ohtubo, Satoshi

    2002-10-01

    This clinical study analyzes our experience of postoperative cardiac function and long-term survival rate in patients with aortic stenosis and small-size St. Jude Medical (SJM) valve. Sixty-eight patients who underwent aortic valve replacement by SJM valve were divided into two groups by preoperative aortic annulus diameter. Group 1 consisted of 44 patients with small aortic annulus and small-size SJM valve (19 mm or 21 mm). In Group 1, small SJM standard valves were implanted in 16 patients, and small SJM Hemodynamic Plus (HP) valves were implanted in 28 patients. Group 2 consisted of 24 patients with large-size SJM standard valve (23 mm or larger). Preoperative left ventricular mass index, left ventricular dimension, the dimension of ascending aorta, and body surface area were significantly smaller in Group 1 than in Group 2. Average age at surgery was older in Group 1 than in Group 2. Effective orifice area index of the SJM valve measured by the manufacturer's data was smaller in Group 1 than in Group 2. Postoperative left ventricular mass indexes of Group 1 (standard valve or HP valve) and Group 2 significantly decreased in comparison with the preoperative mass indexes. Postoperative left ventricular ejection fraction and the peak ejection rate of Group 1 were not different from those of Group 2. The 10 year survival rate of Group 1 was 79%, and the rate of Group 2 was 77%. At 10 years after surgery, freedom from valve-related complication of Group 1 was 80%, and freedom from complication of Group 2 was 81%. Our results demonstrated that small-size SJM valve afforded satisfactory long-term survival rate and valve-related event-free rate for elderly patients with small body surface area and small aortic annulus.

  14. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Related MedlinePlus Health Topics Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  15. Microprocessor-Based Valved Controller

    Science.gov (United States)

    Norman, Arnold M., Jr.

    1987-01-01

    New controller simpler, more precise, and lighter than predecessors. Mass-flow controller compensates for changing supply pressure and temperature such as occurs when gas-supply tank becomes depleted. By periodically updating calculation of mass-flow rate, controller determines correct new position for valve and keeps mass-flow rate nearly constant.

  16. Rotary actuators for plastic valves

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, M. [Georg Fischer Piping Systems Ltd, Schaffhausen (Switzerland)

    2004-07-01

    Flexibility and modularity plus a high level of quality are the defining characteristics of this new generation of actuators from Georg Fischer. In conjunction with the new 546 ball valve, the PA 11/PA 21 pneumatic actuators and the EA 11/EA 21 electric actuators form an optimally co-ordinated system. (orig.)

  17. Manufacturing network evolution

    DEFF Research Database (Denmark)

    Yang, Cheng; Farooq, Sami; Johansen, John

    2011-01-01

    Purpose – This paper examines the effect of changes at the manufacturing plant level on other plants in the manufacturing network and also investigates the role of manufacturing plants on the evolution of a manufacturing network. Design/methodology/approach –The research questions are developed...... by identifying the gaps in the reviewed literature. The paper is based on three case studies undertaken in Danish manufacturing companies to explore in detail their manufacturing plants and networks. The cases provide a sound basis for developing the research questions and explaining the interaction between...... different manufacturing plants in the network and their impact on network transformation. Findings – The paper highlights the dominant role of manufacturing plants in the continuously changing shape of a manufacturing network. The paper demonstrates that a product or process change at one manufacturing...

  18. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  19. Transvalvular mitral regurgitation following mitral valve replacement a diagnostic dilemma

    OpenAIRE

    U S Dinesh Kumar; Umesh Nareppa; Shyam Prasad Shetty; Murugesh Wali

    2015-01-01

    After mitral valve replacement with a prosthetic valve, the valve should be competent and there should not be any residual prosthetic valve regurgitation. Transvalvular residual prosthetic valve regurgitation are difficult to diagnose and quantify. we are reporting interesting TEE images as a diagnostic dilemma in a case of transvalvular mitral regurgitation following mitral valve replacement secondary to entrapment of sub-valvular apparatus in a Chitra mechanical heart valve.

  20. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas;

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacement....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  1. Replacement of Cobalt base alloys hardfacing by NOREM alloy; EDF experience and development, some metallurgical considerations. Valves application (CLAMA, RAMA)

    Energy Technology Data Exchange (ETDEWEB)

    Carnus, M. [EDF DPN UTO Direction Expertise Technique, Noisy le Grand (France); Confort, X. [VELAN SAS, Lyon (France)

    2011-07-01

    Cobalt base alloys, such as Stellite 6 and 21, are used extensively in applications where superior resistance to wear and corrosion are required. However the use of Cobalt alloys hardfacing materials, especially on valves, is a major contributor to the level of radioactive contamination of nuclear facilities. NOREM alloys, an iron base and cobalt free materials, have been developed through an Electric Power Research Institute (EPRI) long running program during the eighties as an alternative of Stellite. This alloy has relatively good weldability properties, it was developed initially for repairing Stellite hardfacing (deposit over existing hardfacing alloys). This alloy has good corrosion resistance properties associated with elevated hardness (HRC 36-42). Technological properties (such as galling resistance, wear resistance) have been evaluated through different testing programs led by EPRI, AECL(Atomic Energy of Canada Limited), Valves manufacturers, EDF and others during the nineties. More recently EDF (for replacement of globe valves) has carried out testing program focused on weld deposit chemistry and mechanical properties. NOREM is a candidate for replacement of stellite hardfacing on valves. However this alloy is not so versatile as stellite alloys regarding technological properties (such as wear resistance) at elevated temperature and under high contact pressure. As a consequence some limits have to be considered for application on valves operating at elevated temperature and under high contact pressure (> 20 Mpa). Examples of application on valves, from VELAN manufacturer, for EDF PWR equipment are given. The industrial feedback from installed equipment (CLAMA, RAMA) since 2006 on EDF PWR has been good

  2. Fault diagnosis of reciprocating compressor valve with the method integrating acoustic emission signal and simulated valve motion

    Science.gov (United States)

    Wang, Yuefei; Xue, Chuang; Jia, Xiaohan; Peng, Xueyuan

    2015-05-01

    This paper proposes a method of diagnosing faults in reciprocating compressor valves using the acoustic emission signal coupled with the simulated valve motion. The actual working condition of a valve can be obtained by analyzing the acoustic emission signal in the crank angle domain and the valve movement can be predicted by simulating the valve motion. The exact opening and closing locations of a normal valve, provided by the simulated valve motion, can be used as references for the valve fault diagnosis. The typical valve faults are diagnosed to validate the feasibility and accuracy of the proposed method. The experimental results indicate that this method can easily distinguish the normal valve, valve flutter and valve delayed closing conditions. The characteristic locations of the opening and closing of the suction and discharge valves can be clearly identified in the waveform of the acoustic emission signal and the simulated valve motion.

  3. Early Clinical Outcome of Mitral Valve Replacement Using a Newly Designed Stentless Mitral Valve for Failure of Initial Mitral Valve Repair.

    Science.gov (United States)

    Nishida, Hidefumi; Kasegawa, Hitoshi; Kin, Hajime; Takanashi, Shuichiro

    2016-12-21

    Here we report the early outcome of mitral valve replacement using a newly designed stentless mitral valve for failure of initial mitral valve repair. Mitral valve plasty (MVP) for mitral regurgitation is currently a standard technique performed worldwide. However, whether mitral valve repair should be performed for patients with advanced leaflet damage or complicated pathology remains controversial. Mitral valve replacement might be feasible for patients who have undergone failed initial MVP; however, it is not an optimal treatment because of poor valve durability and the need for anticoagulative therapy. We report two cases of successful mitral valve replacement using a newly designed stentless mitral valve made of fresh autologous pericardium, which may have a potential benefit over mitral valve repair or mitral valve replacement with a mechanical or bioprosthetic valve.

  4. Standardization of phaseolus vulgaris valves by macro- and microscopic characteristics

    Directory of Open Access Journals (Sweden)

    Анна Ігорівна Крюкова

    2016-03-01

    Full Text Available During the last years on the Ukrainian pharmaceutical market a tendency to increase the range of the national herbal remedies is observed. Native flora herbs, having a sufficient resource base, deserve special attention and are characterized by a number of economic benefits for manufacturers. The implementation of herbal remedies in medical practice is accompanied by the necessity to improve the quality control of herbal material and to develop normative documents. Macro- and microscopy analysis becomes important at standardization of herbal material especially cut and powdered.Aim. The aim of our work was to carry out macro- and microscopy research of Phaseolus vulgaris and to determine its diagnostic morphologic and anatomic features.Methods. The conventional research methods in pharmacognosy have been used; photomicrography has been taken by using microscope MC-10 and Samsung PL 50 camera.Results. As a result of research, the microscopic diagnostic characteristics for Phaseolus vulgaris valves have been proposed, e.g.: the valves are elongated, straight, navicular or grooved, twisted to some extent; the external surface is smooth or slightly undulating, mat, pale yellow or yellow; the internal surface is shiny, white or yellowish-white. Sometimes carpophore (stalk may occur. The microscopic diagnostic features have been determined and offered, e.g.: cells of outer epidermis are pentagonal and hexagonal, with plicated cuticle; stomata are surrounded by 3–4 subsidiary narrow cells, additionally surrounded by 5–6 narrow cells; cover trichomes and glandular trichomes are elongated, pointed and unbranched; xylem vessels and tracheids; non-bundled structure stalk fragments with pericyclic sclerenchyma and secretory cells in the phloem.Conclusion. Research on determination of the macro- and microscopic characteristics of Phaseolus vulgaris valves has been carried out. The diagnostic morphological and anatomic elements in herbal material have

  5. Strategic Roles of Manufacturing

    DEFF Research Database (Denmark)

    Yang, Cheng

    Addressing three development trends of manufacturing, this thesis aims to explore: (1) facing challenges on manufacturing (globalisation, knowledge-based manufacturing and servitisation of manufacturing), what kinds of roles does manufacturing play within industrial companies; (2) along...... with the trend of globalisation, how do industrial companies develop their global manufacturing networks? These two questions are actually interlinked. On the one hand, facing increasing offshoring and outsourcing of production activities, industrial companies have to understand how to develop their global...... manufacturing networks. On the other hand, ongoing globalisation also brings tremendous impacts to post-industrial economies (e.g. Denmark). A dilemma therefore arises, i.e. whether it is still necessary to keep manufacturing in these post-industrial economies; if yes, what kinds of roles manufacturing should...

  6. Framework for Grid Manufacturing

    Institute of Scientific and Technical Information of China (English)

    陈笠; 邓宏; 邓倩妮; 吴振宇

    2004-01-01

    With the development of networked manufacturing, it is more and more imminent to solve problems caused by inherent limitations of network technology, such as heterogeneity, collaboration collision, and decentralized control.This paper presents a framework for grid manufacturing, which neatly combines grid technology with the infrastructure of advanced manufacturing technology.The paper studies grid-oriented knowledge description and acquisition, and constructs a distributed knowledge grid model.The paper also deals with the protocol of node description in collaborative design, and describes a distributed collaborative design model.The protocol and node technology leads to a collaborative production model for grid manufacturing.The framework for grid manufacturing offers an effective and feasible solution for the problems of networked manufacturing.The grid manufacturing will become an advanced distributed manufacturing model and promote the development of advanced manufacturing technologies.

  7. A Kinematic Analysis of the Variable Valve Timing Mechanism with Three Elements and Continuous Valve Lift

    Directory of Open Access Journals (Sweden)

    Stelian Mihalcea

    2010-01-01

    Full Text Available An innovating solution for throttle-free load control for spark-ignition engines is Variable Valve Timing system (VVT System, or VVA - Variable Valve Actuation System. In this paper is presented an analytic method for kinematic analysis of the valve timing mechanism with three elements, which mainly includes the camshaft, the roller rocker finger and an intermediate rocker arm. This type of mechanism ensures a continuous valve lift (VVL System between two extreme valve heights. It is also presented the numerical example for the variable valve lift mechanism’s motion.

  8. Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice

    Institute of Scientific and Technical Information of China (English)

    GUO Hong-wei; PAN Shi-wei; SONG Yun-hu; HU Sheng-shou

    2011-01-01

    Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.

  9. Hydrodynamic Performance of the Medtronic CoreValve and the Edwards SAPIEN XT Transcatheter Heart Valve in Surgical Bioprostheses: An In Vitro Valve-in-Valve Model.

    Science.gov (United States)

    Sedaghat, Alexander; Sinning, Jan-Malte; Utzenrath, Marc; Ghalati, Pejman Farhadi; Schmitz, Christoph; Werner, Nikos; Nickenig, Georg; Grube, Eberhard; Ensminger, Stephan; Steinseifer, Ulrich; Kuetting, Maximilian

    2016-01-01

    Valve-in-valve transcatheter aortic valve replacement (TAVR) is becoming a valuable option with promising clinical results in failed bioprosthetic heart valves. Sizing recommendations are based on size compatibility rather than on broad clinical data, in vitro measurements, or biomechanical evidence. The hemodynamic performance of transcatheter heart valves within degenerated surgical heart valves is unknown. We evaluated the in vitro hydrodynamic performance of two commercially available transcatheter heart valves (Medtronic CoreValve [Medtronic, Minneapolis, MN] and Edwards SAPIEN XT [Edwards Lifesciences, Irvine, CA]) in two different bioprosthetic aortic valves (Edwards Perimount [Edwards Lifesciences] and St. Jude Trifecta [St. Jude Medical, St. Paul, MN]). Within the Edwards Perimount (23 mm) prosthesis, pressure gradients were higher for the SAPIEN XT compared with the CoreValve (11.2 ± 0.1 mm Hg versus 10.1 ± 0.1 mm Hg, p < 0.01), whereas effective orifice area (1.99 ± 0.01 cm(2) versus 1.80 ± 0.01 cm(2), p < 0.01) and total paravalvular leakage (9.0% ± 1.0% versus 5.4% ± 1.3%, p < 0.01) were increased when using the CoreValve. Similarly, measurements in the St. Jude Trifecta revealed higher transvalvular pressure gradients (13.0 ± 0.2 mm Hg versus 10.9 ± 0.3 mm Hg, p < 0.01) and lower effective orifice area for the SAPIEN XT compared with the CoreValve. However, total relative regurgitation was higher with SAPIEN XT as compared with the CoreValve in St. Jude Trifecta prostheses (11.2% ± 1.4% versus 8.3% ± 0.9%, p < 0.01). Both transcatheter heart valve prostheses performed well in the described valve-in-valve settings. Hydrodynamic results were in line with the International Organization for Standardization standards for all configurations. The observed differences indicate a necessity for preclinical valve-in-valve tests in addition to clinical long-term data about longevity. Copyright © 2016 The Society of Thoracic Surgeons. Published by

  10. Numerical simulation for permanent mold centrifugal cast TiAl exhaust valve

    Institute of Scientific and Technical Information of China (English)

    SHENG Wen-bin; LI Dong

    2005-01-01

    The filling and solidification in centrifugal field, as well as the forming mechanism of off-center porosities were summarized, based on the mathematical model established for the centrifugal cast TiAl exhaust valves.The calculated results show that the centrifugal field results in the phenomenon that the flow in the valve cavity consists of forward flow and backward flow. The unsymmetrical initial temperature field causes continuous unsymmetrical variation in the following solidification, which makes the final solidified region depart from the cavity axis and then leads to the occurrence of off-center porosity. A series of optimized parameters, including the entrance velocity of 0.6 - 1.3 m/s, the rotation speed higher than 300 r/min, 80 mm or longer entrance length and 400 ℃ or higher preheated temperature of the mold, are suggested for the manufacture of permanent mold centrifugal cast TiAl exhaust valves.

  11. Static and Dynamic Performance Simulation of Direct-Acting Force Motor Valve

    Science.gov (United States)

    Ye, Xinghai; Ding, Jianjun; Zheng, Gang; Jiang, Kunpeng; Chen, Dongdong

    2017-07-01

    This work focuses on static and dynamic characteristics of direct-acting force motor valve. First, we analyzed the structure features and operating principle of the Mitsubishi-Hitachi force motor valve (FMV) and the operating principle of its internal permanent-magnet moving-coil force motor magnetic circuit, determined the transfer function of the FMV force motor system, and established a mathematical model for the system. Secondly, we established a static performance analysis model using the AMESIM software and utilized the model in combination with experimental results to analyze the effects of electro-hydraulic servo valve structural parameters on static characteristics. Lastly, we deduced the trajectory equation of the system, established the relationship between dynamic characteristic indexes and structural parameters, and analyzed the effects of different parameter values on the dynamic characteristics of the system. This research can provide a theoretical guidance for designing and manufacturing the FMV body.

  12. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  13. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  14. 49 CFR 179.500-11 - Loading and unloading valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Loading and unloading valves. 179.500-11 Section...-113 and 107A) § 179.500-11 Loading and unloading valves. (a) Loading and unloading valve or valves shall be mounted on the cover or threaded into the marked end of tank. These valves shall be of...

  15. Segmented ball valve is easy to open and close

    Science.gov (United States)

    Prono, E.; Shinault, L. H.; Speisman, C.

    1966-01-01

    Segmented ball valve and flowmeter in the same spherical housing provide a valve that will handle large fluid volume without bulkiness and weight of blade valves or conventional ball valves. The valve is easily opened or closed and the flowmeter remains stationary, so errors are eliminated.

  16. Transesophageal echocardiography evaluation of tricuspid and pulmonic valves

    Directory of Open Access Journals (Sweden)

    Aneeta Bhatia

    2016-01-01

    Full Text Available The tricuspid is the lost valve and the pulmonary being the most anterior, is not visualized well on TEE; The Pulmonary valve is a semilunar valve that separates the right ventricle from the pulmonary artery. It is situated anterior and superior to the aortic valve, almost at right angle to the aortic valve and parallel to the beam of the ultrasound.

  17. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  18. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  19. [Redo Aortic and Mitral Valve Replacement by Manouguian's Procedure for Active Prosthetic Valve Infection].

    Science.gov (United States)

    Kunitomo, Ryuji; Okamoto, Ken; Moriyama, Shuji; Sakaguchi, Hisashi; Tazume, Hirokazu; Yoshinaga, Takashi; Kawasuji, Michio

    2016-03-01

    The damage to the intervalvular fibrous trigone (IVFT) by infective endocarditis makes combined aortic and mitral valve replacement difficult. We performed Manouguian's double valve replacement for such a case and obtained a good result. A 81-year-old male underwent emergency operation due to active prosthetic valve endocarditis. He had a history of receiving combined aortic and mitral valve replacement because of active infective endocarditis at the age of 74 and redo aortic valve replacement 3 years after that. The infectious lesion extended from the mitral annulus to the IVFT and the aortic annulus, and it caused the prosthetic valve detachment from the aortic annulus. Manouguian's double valve replacement was required for radical resection and reconstruction of the IVFT. No recurrent infection or paravalvular leakage was observed during 49months follow up period. Manouguian's procedure is useful for complete resection of the infected IVFT and makes combined aortic and mitral valve replacement safer.

  20. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Hwan [Pusan National University, Busan (Korea, Republic of)

    2009-09-15

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  1. Percutaneous implantation of CoreValve aortic prostheses in patients with a mechanical mitral valve.

    Science.gov (United States)

    Bruschi, Giuseppe; De Marco, Federico; Oreglia, Jacopo; Colombo, Paola; Fratto, Pasquale; Lullo, Francesca; Paino, Roberto; Frigerio, Maria; Martinelli, Luigi; Klugmann, Silvio

    2009-11-01

    Concerns exist in the field of transcatheter aortic valve implantation regarding the treatment of patients with mechanical mitral valve for possible interference between the percutaneous aortic valve and the mechanical mitral prosthesis. We report our experience with percutaneous aortic valve implantation in 4 patients with severe aortic stenosis, previously operated on for mitral valve replacement with a mechanical prosthesis. All patients underwent uneventful percutaneous retrograde CoreValve implantation (CoreValve Inc, Irvine, CA). No deformation of the nitinol tubing of the prostheses (ie, neither distortion nor malfunction of the mechanical valve in the mitral position) occurred in any of the patients. All patients are alive and asymptomatic at a mean follow-up of 171 days.

  2. Northwest Manufacturing Initiative

    Science.gov (United States)

    2014-07-31

    warehouse. If the batch of lenses is faulty, the manufacturer wants to know ASAP in order to send Visionary Lenses a new batch of lenses. The manufacturer ...increased. • A few years ago, Nike started using pre-consumer Nike Grind – (scrap material from their manufacturing facilities) – in new ...Northwest ( in particular with firms in the manufacturing eco-system of defense supply chains). Special emphasis was placed to increase the

  3. Manufacturing in Denmark

    DEFF Research Database (Denmark)

    Hansen, Johannes; Boer, Henrike Engele Elisabeth; Boer, Harry

    This report compares the manufacturing strategies, practices, performances and improvement activities of 39 companies that are representative for the Danish assembly industry with those of 804 companies from 19 other countries. The data supporting this report were collected in 2013 and concern......: • Manufacturing strategies pursued and implemented between 2010 and 2012. • Performance improvements achieved during that period. • Actual manufacturing practices and performances as well as competitive priorities in 2012. • Manufacturing strategies pursued for the years 2010-2012....

  4. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  5. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  6. 3D Printed Multimaterial Microfluidic Valve

    Science.gov (United States)

    Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics. PMID:27525809

  7. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  8. Designing using manufacturing features

    Science.gov (United States)

    Szecsi, T.; Hoque, A. S. M.

    2012-04-01

    This paper presents a design system that enables the composition of a part using manufacturing features. Features are selected from feature libraries. Upon insertion, the system ensures that the feature does not contradict the design-for-manufacture rules. This helps eliminating costly manufacturing problems. The system is developed as an extension to a commercial CAD/CAM system Pro/Engineer.

  9. STUDY ON FLUID THICKNESS BETWEEN POPPET AND VALVE GUIDE IN CONTROL VALVE OF INJECTOR

    Institute of Scientific and Technical Information of China (English)

    Zhang Jianming; Zhang Weigang; Wang Yawei

    2004-01-01

    The physical model of -20 diesel oil and force model of injector control valve of common rail system is built. The changes of the fluid thickness are investigated on the base of the results of CFD and experiments for control valve of injector. The results indicate that a fluid thickness of 0.02~0.03 mm between the poppet and valve guide is sufficient to dampen any excessive control valve poppet bouncing.

  10. Improved valve and dash-pot assembly

    Science.gov (United States)

    Chang, S.C.

    1985-04-23

    A dash-pot valve comprises a cylinder submerged in the fluid of a housing and have a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with targentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  11. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  12. Check valve slam analysis in pumping station

    Science.gov (United States)

    Himr, D.; Habán, V.; Dokoupil, P.

    2016-03-01

    Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

  13. Low-Pressure-Drop Shutoff Valve

    Science.gov (United States)

    Thornborrow, John

    1994-01-01

    Flapper valve remains open under normal flow conditions but closes upon sudden increases to high rate of flow and remains closed until reset. Valve is fluid/mechanical analog of electrical fuse or circuit breaker. Low-pressure-drop shutoff valve contains flapper machined from cylindrical surface. During normal flow conditions, flapper presents small cross section to flow. (Useful in stopping loss of fluid through leaks in cooling systems.)

  14. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  15. Bistable (latching) solenoid actuated propellant isolation valve

    Science.gov (United States)

    Wichmann, H.; Deboi, H. H.

    1979-01-01

    The design, fabrication, assembly and test of a development configuration bistable (latching) solenoid actuated propellant isolation valve suitable for the control hydrazine and liquid fluorine to an 800 pound thrust rocket engine is described. The valve features a balanced poppet, utilizing metal bellows, a hard poppet/seat interface and a flexure support system for the internal moving components. This support system eliminates sliding surfaces, thereby rendering the valve free of self generated particles.

  16. Inertia charging system with a rotary valve. Kaitenben wo mochiita kansei kakyu system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, H.; Ji, D. (The University of Tokyo, Tokyo (Japan). Faculty of Engineering); Kanesaka, H.; Lee, D.

    1991-10-01

    An inertia charger which is used to raise the output of an internal combustion engine can raise the volumetric efficiency by using the dynamic effect of intake air vibration which takes place in the intake system during the intake process. This paper described the trial manufacturing of an inertia charging system aiming at the high volumetric efficiency by arranging the rotary valve in the intake passage and by adjusting the operating time of the rotary valve and the studied result to improve the effect of inertia charging over the wide range of engine rotational speed. The experimental equipment was a 399cc single cylinder gasoline engine for a bicycle to which intake port a rotary valve was fitted. The engine number of rotation, volumetric efficiency, crank angle and the pressure change near the rotary valve were studied. As a result, the aerofoil rotary valve could improve the volumetric efficiency over a wide range of engine number of rotation, compared with the conventional inertia charging system. The optimized calculation result by which the future expansion of this system was studied, was shown. 3 refs., 4 figs., 3 tabs.

  17. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  18. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  19. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  20. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  1. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  2. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...

  3. Matching flow characteristics of standard shutoff valves eliminates need for custom fabricated valves

    Science.gov (United States)

    Bevan, A. F.

    1966-01-01

    Standard high pressure valves are used in low pressure fluid system testing when a substantial system pressure increase is required. The flow-vs-valve stroke is matched with that of the valves being replaced. Some correction to the plug contour may be necessary.

  4. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  5. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  6. Repositioning of an Intraventricular Dislocated Aortic Valve during Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Natour, Ehsan; Douglas, Yvonne L.; Jainandunsing, Jayant S.; Schurer, Remco A. J.; van der Werf, Hendrik W.; van den Heuvel, Ad F. M.

    2014-01-01

    The case is presented of a 75-year-old man referred for transcatheter aortic valve implantation. During the procedure the prosthetic aortic valve became dislocated into the left ventricle shortly after expansion. The subsequent steps taken to reposition the valve using only materials at hand are des

  7. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  8. Advanced Manufacturing Technologies (AMT): Manufacturing Initiative Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA supports the Advanced Manufacturing National Program Office (AMNPO). Hosted by the National Institute of Standards and Technology (NIST) the AMNPO is...

  9. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  10. Decellularized allogeneic heart valves demonstrate self-regeneration potential after a long-term preclinical evaluation.

    Science.gov (United States)

    Iop, Laura; Bonetti, Antonella; Naso, Filippo; Rizzo, Stefania; Cagnin, Stefano; Bianco, Roberto; Dal Lin, Carlo; Martini, Paolo; Poser, Helen; Franci, Paolo; Lanfranchi, Gerolamo; Busetto, Roberto; Spina, Michel; Basso, Cristina; Marchini, Maurizio; Gandaglia, Alessandro; Ortolani, Fulvia; Gerosa, Gino

    2014-01-01

    and specific topographic distribution in respect to control valves. Following the longest follow-up ever realized in preclinical models, non-preconditioned decellularized allogeneic valves offer suitable microenvironment for in vivo cell homing and tissue remodeling. Manufactured with simple, timesaving and cost-effective procedures, these promising valve replacements hold promise to become an effective alternative, especially for pediatric patients.

  11. Decellularized allogeneic heart valves demonstrate self-regeneration potential after a long-term preclinical evaluation.

    Directory of Open Access Journals (Sweden)

    Laura Iop

    higher number and specific topographic distribution in respect to control valves. Following the longest follow-up ever realized in preclinical models, non-preconditioned decellularized allogeneic valves offer suitable microenvironment for in vivo cell homing and tissue remodeling. Manufactured with simple, timesaving and cost-effective procedures, these promising valve replacements hold promise to become an effective alternative, especially for pediatric patients.

  12. Manufacturing Planning Guide

    Science.gov (United States)

    Waid, Michael

    2011-01-01

    Manufacturing process, milestones and inputs are unknowns to first-time users of the manufacturing facilities. The Manufacturing Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their project engineering personnel in manufacturing planning and execution. Material covered includes a roadmap of the manufacturing process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  13. Towards maintenance-free SOVs (solenoid operated valves). [For nuclear power plant use

    Energy Technology Data Exchange (ETDEWEB)

    Rustagi, R. (Valcor Engineering Corp., Springfield, NJ (USA))

    1991-05-01

    Because most solenoid operated valves (SOVs) are being used in vital safety related systems in nuclear power plants, they must be shown to perform satisfactorily over 40 years of normal service plus one year into post-LOCA. Current practice in SOV design and manufacture, as described here, aims to minimize the need for maintenance and to make it simpler when it is necessary. (author).

  14. Variable Inlet and Exhaust Valve Operation in Medium Speed Marine Diesel Engines

    OpenAIRE

    Sæle, Hans Steffen Ravnanger

    2010-01-01

    This thesis was successfully completed through five main parts. First a lingering issue of great importance was dealt with in order to start the use of the provided simulation model. This task was imperative to accurate simulation results as it aimed to ensure matching definitions between simulation software and the engine manufacturer. A satisfactory result was quickly obtained.Secondly some sections are spent mapping the potential performance benefits of a camless valve train. This part has...

  15. Theoretical analysis and experimental verification on valve-less piezoelectric pump with hemisphere-segment bluff-body

    Science.gov (United States)

    Ji, Jing; Zhang, Jianhui; Xia, Qixiao; Wang, Shouyin; Huang, Jun; Zhao, Chunsheng

    2014-05-01

    Existing researches on no-moving part valves in valve-less piezoelectric pumps mainly concentrate on pipeline valves and chamber bottom valves, which leads to the complex structure and manufacturing process of pump channel and chamber bottom. Furthermore, position fixed valves with respect to the inlet and outlet also makes the adjustability and controllability of flow rate worse. In order to overcome these shortcomings, this paper puts forward a novel implantable structure of valve-less piezoelectric pump with hemisphere-segments in the pump chamber. Based on the theory of flow around bluff-body, the flow resistance on the spherical and round surface of hemisphere-segment is different when fluid flows through, and the macroscopic flow resistance differences thus formed are also different. A novel valve-less piezoelectric pump with hemisphere-segment bluff-body (HSBB) is presented and designed. HSBB is the no-moving part valve. By the method of volume and momentum comparison, the stress on the bluff-body in the pump chamber is analyzed. The essential reason of unidirectional fluid pumping is expounded, and the flow rate formula is obtained. To verify the theory, a prototype is produced. By using the prototype, experimental research on the relationship between flow rate, pressure difference, voltage, and frequency has been carried out, which proves the correctness of the above theory. This prototype has six hemisphere-segments in the chamber filled with water, and the effective diameter of the piezoelectric bimorph is 30mm. The experiment result shows that the flow rate can reach 0.50 mL/s at the frequency of 6 Hz and the voltage of 110 V. Besides, the pressure difference can reach 26.2 mm H2O at the frequency of 6 Hz and the voltage of 160 V. This research proposes a valve-less piezoelectric pump with hemisphere-segment bluff-body, and its validity and feasibility is verified through theoretical analysis and experiment.

  16. REDUCING THE REJECTION RATE OF ENGINES MANUFACTURING DUE TO INJECTION TIMING VARIATION

    Directory of Open Access Journals (Sweden)

    Mrs. P.SIVASHANKARI

    2015-12-01

    Full Text Available The white paper is on HINO 6 cylinder engine and the aim is to reduce the rejection rate of engines during testing due to the problems occur in valve timing and injection timing. The concept of Six Sigma is mainly practiced as a design to eliminate the production defects by improving the process of manufacturing. In the observation, the injection timing mark (spill mark is not perfectly done and also the imperfection in flywheel marking machine locator pin increases engine rejection. The aim is to eliminate the engines getting rejected during engine test due to problems arising in the injection timing and valve timing. As there are a lot of problems arising in the test bed where the engine is tested, few of which are related to injection timing and valve timing. These problems mainly arise due to changes in the valve and injection timing variation.

  17. Discussion on advanced manufacturing

    Institute of Scientific and Technical Information of China (English)

    WANG Xiankui

    2007-01-01

    Advanced manufacturing consists of continuity of manufacturing,its broad sense,and the core of the manufacturing process.The technology of continuous manufacturing is discussed according to both historical and modern perspectives.The relationship between human development and manufacturing technology is also discussed.Manufacturing is a continuously evolving topic.It is not only the foundation and means of imagination,conception,the science,and the technology of material change,but also the expression of national economy,national defense,and the support industries.The broad sense of manufacturing theory,which extends the concept of manufacturing,is an important development in the 20th century.The sense is analyzed in connection with design,material forming theory,synthesis of manufacturing technology,manufacturing modes,life cycle of product,hardware and sottware,and support environment,etc.At the same time,the core action and the development of the theory and technology of process is also discussed.At the end of this paper,the development directions of mechanical manufacturing science and technology are mentioned.

  18. Improving the pneumatic control valve performance using a PID controller

    OpenAIRE

    Heidari, Mohammad; Homaei, Hadi

    2014-01-01

    Pneumatic control valves are still the most used in process industries due to their low cost and simplicity. This paper presents a design procedure of a PID controller for a pneumatic control valve. For comparison, P and PI controllers are also utilized for the control valve. The bond graph method is used to model the control valve, in order to compare the response characteristics of the valve. Simulation results are found for three controllers of the valve. The integral time absolute error c...

  19. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    Directory of Open Access Journals (Sweden)

    Abulon DJ

    2015-09-01

    Full Text Available Dina Joy Abulon,1 Martin Charles,2 Daniel E Charles21Global Medical Affairs, Alcon Laboratories, Inc., Lake Forest, CA, USA; 2Centro Oftalmológico Dr Charles, Buenos Aires, ArgentinaPurpose: To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP, fluid leakage, and vitreous incarceration during simulated vitrectomy.Methods: Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes.Results: In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005, and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05 and 27-gauge (P<0.05 non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas.Conclusion: Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy.Keywords: IOP, fluid leakage, vitreous incarceration

  20. Transaortic aortic valve replacement using the Edwards Sapien-XT Valve and the Medtronic CoreValve: initial experience.

    Science.gov (United States)

    Spargias, Konstantinos; Bouboulis, Nikolaos; Halapas, Antonios; Chrissoheris, Michael; Skardoutsos, Spyridon; Nikolaou, Joulia; Tsolakis, Apostolos; Mourmouris, Christos; Pattakos, Stratis

    2014-01-01

    Transcatheter aortic valve replacement (TAVR) is now an established treatment for certain patients with severe aortic valve stenosis (AS). However, as the number of patients screened for TAVR increases, many are found to have absolutely no option for peripheral artery access. Transaortic valve replacement (TAoVR) has been proposed as a new alternative route in patients deemed unsuitable for conventional approaches. We present our first series of TAoVR cases using the Edwards Sapien-XT and the Medtronic CoreValve prostheses. Twenty-five (25) symptomatic patients (mean age 78 ± 8 years, mean logistic EuroSCORE I 25 ± 11%) with severe AS underwent TAoVR using the Sapien-XT valve (10 patients) or the CoreValve (15 patients). The mean fluoroscopy time was 15.6 ± 4.2 minutes, the mean time in the intensive care unit was 1.9 ± 1.0 days, and the mean hospital stay was 6.4 ± 1.6 days. The mean effective aortic valve area increased (from 0.68 ± 0.15 cm(2) to 1.82 ± 0.34 cm(2), pMedtronic CoreValve prosthesis demonstrated that it could be performed safely, resulting in substantial acute echocardiographic and early clinical improvement.

  1. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  2. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm.

    Science.gov (United States)

    Tomsic, Anton; Li, Wilson W L; van Paridon, Marieke; Bindraban, Navin R; de Mol, Bas A J M

    2016-08-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred after the aneurysm perforated. The patient showed no signs of heart failure and completed a 6-week regimen of antibiotic therapy before undergoing successful aortic and mitral valve replacement. In addition to the patient's case, we review the relevant medical literature.

  3. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  4. Aortic and Mitral Valve Replacement Through a Single Transverse Aortotomy: A Useful Approach in Difficult Mitral Valve Exposure

    OpenAIRE

    Carmichael, Michael J.; Cooley, Denton A.; Favor, Arsenio S.

    1983-01-01

    Replacement of the mitral valve through a standard vertical left atriotomy in patients requiring both aortic and mitral valve replacement can be very difficult. This is especially true in patients who have undergone previous median sternotomy. Replacement of the mitral valve through the aortic root after excision of the aortic valve is described in two case reports. This is a convenient approach when traditional exposure of the mitral valve is impractical in patients requiring double valve re...

  5. Left atrial ball valve thrombus

    Directory of Open Access Journals (Sweden)

    R. Balaji

    2013-10-01

    Full Text Available "Ball valve thrombus" which is a spherical free floating clot in left atrium is an often quoted, but uncommonly encountered complication in patients with severe mitral stenosis of rheumatic origin, who are in atrial fibrillation. We describe the case of a 31-year-old lady with rheumatic heart disease, severe mitral stenosis and moderately severe aortic stenosis who had undergone closed mitral valvotomy 13 years ago. The patient presented with an episode of non-exertional syncope and breathlessness on exertion of 6 months duration and was in normal sinus rhythm. Echocardiography facilitated ante-mortem diagnosis and prompt institution of surgery was life saving.

  6. On-pump fibrillating heart mitral valve replacement with the SAPIEN™ XT transcatheter heart valve.

    Science.gov (United States)

    Ferrari, Enrico; Niclauss, Lars; Locca, Didier; Marcucci, Carlo

    2014-04-01

    In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien™ XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.

  7. Predictors of mortality after aortic valve replacement

    NARCIS (Netherlands)

    Tjang, Yanto Sandy; van Hees, Yvonne; Koerfer, Reiner; Grobbee, Diederick E.; van der Heijden, Geert J. M. G.

    Aortic valve replacement (AVR) is recommended as a standard surgical procedure for aortic valve disease. Still the evidence for commonly claimed predictors of post-AVR prognosis, in particular mortality, appears scant. This systematic review reports on the evidence for predictors of post-AVR

  8. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  9. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each...

  10. A highly sensitive spin-valve transistor

    NARCIS (Netherlands)

    Erve, van 't O.M.J.; Vlutters, R.; Anil Kumar, P.S.; Kim, S.D.; Jansen, R.; Lodder, J.C.; Hadjipanayis, G.C.

    2001-01-01

    In this paper we present a spin-valve transistor made with a silicon on insulator wafer as emitter and a double sided polished Si wafer as collector. Using vacuum metal bonding we obtain a three terminal device in which a spin-valve layer is sandwiched between two Si wafers. We measure a 217% change

  11. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature.

  12. Whole Teflon valves for handling droplets.

    Science.gov (United States)

    Cybulski, Olgierd; Jakiela, Slawomir; Garstecki, Piotr

    2016-06-21

    We propose and test a new whole-Teflon gate valve for handling droplets. The valve allows droplet plugs to pass through without disturbing them. This is possible due to the geometric design, the choice of material and lack of any pulses of flow generated by closing or opening the valve. The duct through the valve resembles a simple segment of tubing, without constrictions, change in lumen or side pockets. There are no extra sealing materials with different wettability or chemical resistance. The only material exposed to liquids is FEP Teflon, which is resistant to aggressive chemicals and fully biocompatible. The valve can be integrated into microfluidic systems: we demonstrate a complex system for culturing bacteria in hundreds of microliter droplet chemostats. The valve effectively isolates modules of the system to increase precision of operations on droplets. We verified that the valve allowed millions of droplet plugs to safely pass through, without any cross-contamination with bacteria between the droplets. The valve can be used in automating complex microfluidic systems for experiments in biochemistry, biology and organic chemistry.

  13. 46 CFR 64.67 - Shutoff valve.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Shutoff valve. 64.67 Section 64.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.67 Shutoff valve. A shutoff...

  14. Digital hydraulic valving system. [design and development

    Science.gov (United States)

    1973-01-01

    The design and development are reported of a digital hydraulic valving system that would accept direct digital inputs. Topics include: summary of contractual accomplishments, design and function description, valve parameters and calculations, conclusions, and recommendations. The electrical control circuit operating procedure is outlined in an appendix.

  15. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  16. Inexpensive tamper proof safety relief valve

    Science.gov (United States)

    Frankewich, P. A.

    1970-01-01

    Basic relief valve has added safety relief valve capability that relieves overpressure before failure can occur. It may be installed in inaccesible areas with a high degree of reliability, constructed from a variety of materials, and adapted to the user's specific application.

  17. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter;

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  18. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  19. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  20. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan;

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  1. Repair for acquired aortic valve disease.

    Science.gov (United States)

    Antunes, M J

    1996-10-01

    The favorable results of mitral valvuloplasty when compared with valve replacement have renewed the interest of many surgeons in aortic valve repair. However, these efforts have, for the most part, been unsuccessful. Also, the results of aortic valve replacement are usually better than those of mitral valve replacement. Yet, some patients appear to derive benefit from a conservative aortic valve procedure. The best examples are mild or moderate aortic valve disease associated with mitral valve or coronary artery disease, which constitute the primary indication for operation, where "prophylactic" aortic valve replacement does not appear justifiable. Other possible indications for aortic valvuloplasty includes patient's lack of compliance or contraindication to anticoagulation in young patients. Senile aortic stenosis, in very old patients with a small annulus, preserved leaflet morphology and nonsignificant commissural fusion should be considered for repair. However, since the procedure is not easily reproducible and the results not uniformly predictable, it cannot be recommended for generalized use. Nonetheless, experienced surgeons should be encouraged to continue these efforts.

  2. [Surgical Treatment of Prosthetic Valve Endocarditis].

    Science.gov (United States)

    Kaminishi, Yuichiro; Akutsu, Hirohiko; Sugaya, Akira; Kurumisawa, Soki; Takazawa, Ippei; Sato, Hirotaka; Muraoka, Arata; Aizawa, Kei; Ohki, Shinichi; Saito, Tsutomu; Kawahito, Koji; Misawa, Yoshio

    2015-11-01

    Between 2003 and 2014, at Jichi Medical University Hospital, 11 patients with prosthetic valve endocarditis (PVE) underwent re-operation. There was 1 in-hospital death and 2 late deaths. The cause of death was cirrhosis, heart failure and sepsis, respectively. Emergency surgery, previous double valve replacement (DVR) and Staphylococcus infection were common risk factors for all 3 cases. Two cases of patients that survived who underwent mitral valve replacement (MVR) and DVR for PVE after DVR were treated with multiple antibiotic courses for bacteremia associated with hemodialysis and colon cancer. One patient who underwent DVR after mitral valve plasty which was complicated with cerebral hemorrhage, had survived and was discharged. Of the aortic PVE patients, 2 cases of aortic valve replacement (AVR) using a mechanical valve, 1 case of aortic root replacement (ARR) using a mechanical valve, and 1 ARR using the homograft, were considered cured and never relapsed. A patient with aortic PVE, who underwent AVR after cesarean section for heart failure in birth period, has received ARR twice with the mechanical valve for recurrent pseudo-aneurysm of the left ventricular outflow tract. Since hemodialysis and colon cancer is a risk factor for recurrent PVE, it is necessary to consider the long-term administration of antibiotics after surgery.

  3. Transcatheter aortic valve replacement in elderly patients

    Institute of Scientific and Technical Information of China (English)

    Dimytri Siqueira; Alexandre Abizaid; Magaly Arrais J.; Eduardo Sousa

    2012-01-01

    Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patients with symptomatic severe aortic stenosis. However, despite the good results of classic surgery, risk is markedly increased in elderly patients with co-morbidities. Transcatheter aortic valve replacement (TAVR) allows implantation of a prosthetic heart valve within the diseased native aortic valve without the need for open heart surgery and cardiopulmonary bypass, offering a new therapeutic option to elderly patients considered at high surgical risk or with contraindications to surgery. To date, several multicenter registries and a randomized trial have confirmed the safety and efficacy of TAVR in those patients. In this chapter, we review the background and clinical applications of TAVR in elderly patients.

  4. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  5. [Interventional mitral valve replacement. Current status].

    Science.gov (United States)

    Lutter, G; Frank, D

    2016-02-01

    Approximately 30 % of patients suffering from severe valvular heart disease, such as mitral valve regurgitation are non-compliant to the gold standard of minimally invasive surgery, reconstruction or valve replacement. The number of these mostly old patients with severe comorbidities is increasing; therefore, transcatheter interventions have been developed to address an unmet clinical need and may be an alternative therapeutic option to the reference standard. Apart from the successful MitraClip therapy, alternative transcatheter reconstruction technologies are being developed. As with transcatheter aortic valve implantation (TAVI) procedures, the off-pump implantation of a valved stent into the mitral position mainly via a transapical approach will be of great benefit. Recently, the feasibility of transcatheter mitral valved stent implantation in high-risk patients has already been reported.

  6. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.

  7. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj;

    2015-01-01

    OBJECTIVES: As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach. METHODS......: Three consecutive patients with an Society of Thoracic Surgeons (STS) mortality score of >22% were selected for transcatheter mitral valve implantation (TMVI) on compassionate grounds. All patients were elderly, had severe mitral regurgitation (MR), were in Class IV heart failure and deemed unsuitable...... bypass surgery (n = 2), severe pulmonary hypertension (n = 1) and moderate to severe chronic renal failure (n = 3). A CardiAQ mitral valve was implanted using fluoroscopy and transoesophageal (TEE) guidance via a standard transapical approach. RESULTS: Accurate prosthesis positioning and deployment...

  8. MEASURING MANUFACTURING INNOVATIVENESS

    DEFF Research Database (Denmark)

    Blichfeldt, Henrik; Knudsen, Mette Præst

    2017-01-01

    Globalization and customization increases the pressure on manufacturing companies, and the ability to provide innovativeness is a potential source of competitive advantage. This paper positions the manufacturing entity in the innovation process, and investigates the relation between innovation vers...... technology and organizational concepts. Based on Danish survey data from the European Manufacturing Survey (EMS-2015) this paper finds that there is a relation between innovative companies, and their level of technology and use of organizational concepts. Technology and organizational concepts act...... as manufacturing levers to support the manufacturing and production system to provide innovativeness. The managerial implication lies in building manufacturing capabilities to support the innovative process, by standardization, optimization and creating stability in combination with automation and advanced...

  9. [Dynamic and cinematic evaluation of the function of bioprosthesis in the aortic position: tester of cardiac valves].

    Science.gov (United States)

    Bustamante, J; Santamaría, J; Infante, O; Flores, P; Juárez, A

    1996-01-01

    Twenty four pericardial valvular prostheses were tested in a valvular tester device. The valves considered were: 12 valves of the model that has being already in clinical use, manufactured in the Instituto Nacional de Cardiología "Ignacio Chávez", (INC II) and 12 valves of a model in an experimental stage, (PRT I.) The inner diameter in the two group considered were: 17, 19 and 21 mm. All the valves were tested in the aortic position in the valvular tester device. Behavior of the valvular prostheses were examined at various rates of pulsation, 60, 77, 105 and 159 per minute, with an ejection volume of 70 and 80 ml (range of flows between 4200 and 12720 ml min1). The pressure of the ventricular and aortic cameras were registered continuously, by external transducers, and in the other hand, the kinetic of the valves and the degree of opening were evaluated for direct view trough an special window. The grade of incompetence was too evaluated and expressed in percent of the stroke volume. The transvalvular pressure gradient was lower in INC II model valves, specially at moderate and high flows, and at same time had a largest functional area. The degree of incompetence was higher in the 19 and 21 mm diameter valvular subgroups than the same subgroups in the PRT I model. In relation to the 17 mm subgroup, significant differences were not find. The use of the valvular tester showed a basic utility in the hydrodynamic evaluation of the news bioprostheses design, and so in the quality control of the valves than has being manufacturing.

  10. Manufacturing ontology through templates

    Directory of Open Access Journals (Sweden)

    Diciuc Vlad

    2017-01-01

    Full Text Available The manufacturing industry contains a high volume of knowhow and of high value, much of it being held by key persons in the company. The passing of this know-how is the basis of manufacturing ontology. Among other methods like advanced filtering and algorithm based decision making, one way of handling the manufacturing ontology is via templates. The current paper tackles this approach and highlights the advantages concluding with some recommendations.

  11. Impact of Formulation Properties and Process Parameters on the Dispensing and Depositioning of Drug Nanosuspensions Using Micro-Valve Technology.

    Science.gov (United States)

    Bonhoeffer, Bastian; Kwade, Arno; Juhnke, Michael

    2017-04-01

    Flexible manufacturing processes with continuously adjustable dose strengths are considered particularly innovative and interesting for applications in personalized medicine, continuous manufacturing, or early drug development. A piezo-actuated micro-valve has been investigated for the dispensing and depositioning of drug nanosuspensions onto substrates to facilitate the manufacturing of solid oral dosage forms. The investigated micro-valve has been characterized regarding dispensing behavior, mass flow, accuracy, and robustness. The amount of dispensed drug compound during 1 dispensing event could be continuously adjusted from a few micrograms to several milligrams with high accuracy. Fluid properties, dispensing parameters of the micro-valve, and the resulting steady state mass flow could be correlated adequately for low-viscous drug nanosuspensions. High-speed imaging was used to investigate the dispensing behavior of the micro-valve regarding the evolution of the dispensed drug nanosuspension after ejection from the nozzle and the behavior during impact on flat and dry solid substrates. The experimentally determined breakup length of the dispensed liquid jet could be correlated with a semiempirical equation. From image sequences of the jet impact, We-Re phase diagrams could be established, providing a profound understanding and systematic guidance for the controlled depositioning of the entire dispensed drug nanosuspension onto the substrate.

  12. Advanced Manufacturing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Manufacturing Laboratory at the University of Maryland provides the state of the art facilities for realizing next generation products and educating the...

  13. Composite Structures Manufacturing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Composite Structures Manufacturing Facility specializes in the design, analysis, fabrication and testing of advanced composite structures and materials for both...

  14. Manufacturing Demonstration Facility (MDF)

    Data.gov (United States)

    Federal Laboratory Consortium — The U.S. Department of Energy Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides a collaborative, shared infrastructure to...

  15. Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated aortic bioprosthesis.

    Science.gov (United States)

    Bruschi, Giuseppe; DeMarco, Federico; Oreglia, Jacopo; Colombo, Paola; Fratto, Pasquale; Lullo, Francesca; Paino, Roberto; Martinelli, Luigi; Klugmann, Silvio

    2010-03-01

    In recent years percutaneous aortic valve implantation has emerged as an alternative therapy to treat patients with symptomatic aortic stenosis considered to be high-risk surgical candidates. We report our experience of a percutaneous retrograde CoreValve implantation in a 77-year-old female with aortic bioprosthesis structural degeneration. The patient underwent aortic valve replacement for aortic stenosis in 1999 with the implantation of a 23 mm Carpentier-Edwards; her last echocardiography showed a severe bioprosthesis stenosis. After evaluation by cardiac surgeons and cardiologist, considering the high risk re-do surgical procedure (Logistic Euroscore 30%) and severe comorbidities (severe pulmonary hypertension, hepatocellular carcinoma and severe osteoporosis), a percutaneous aortic valve-in-valve replacement was preferred. A successful percutaneous 26 mm CoreValve prosthesis implantation was performed with the patient awake with local anesthesia and mild sedation. The patient was discharged after 10 days of hospitalization and she is in NYHA functional class I at follow-up. Our experience, characterized by a multidisciplinary approach, necessary to offer the safest conditions and care for patients, demonstrates the feasibility of a new, promising indication for the use of a transcatheter valve implantation: percutaneous treatment of a degenerated aortic bioprosthesis.

  16. Posttraumatic tricuspid valve injury and severe tricuspid valve regurgitation.

    Science.gov (United States)

    Gucuk Ipek, Esra

    2013-09-01

    A 66-year-old male was brought to our hospital following a car accident. He had subarachnoid hemorrhage, multiple rib fractures, and left hemopneumothorax. He was referred to the Cardiology Department for elevated troponin levels (42 ng/ml, reference 0-1 ng/ml). The electrocardiogram was free of ischemia, whereas the transthoracic echocardiography revealed dilated right heart chambers, enlarged tricuspid annulus and coaptation failure of the tricuspid valvular leaflets. There was rupture on the subvalvular apparatus of the anterior leaflet of the tricuspid valve with accompanying prolapse, causing severe tricuspid valvular regurgitation. The patient did not present right ventricular failure signs and symptoms; he was referred to surgery after the resolution of associated thoracic and cranial injuries.

  17. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  18. Post-market surveillance to detect adverse events associated with Melody® valve implantation.

    Science.gov (United States)

    Hill, Kevin D; Goldstein, Bryan H; Angtuaco, Michael J; Chu, Patricia Y; Fleming, Gregory A

    2017-08-01

    The aim of this study was to describe previously unrecognised or under-recognised adverse events associated with Melody® valve implantation. In rare diseases and conditions, it is typically not feasible to conduct large-scale safety trials before drug or device approval. Therefore, post-market surveillance mechanisms are necessary to detect rare but potentially serious adverse events. We reviewed the United States Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database and conducted a structured literature review to evaluate adverse events associated with on- and off-label Melody® valve implantation. Adverse events were compared with those described in the prospective Investigational Device Exemption and Post-Market Approval Melody® transcatheter pulmonary valve trials. We identified 631 adverse events associated with "on-label" Melody® valve implants and 84 adverse events associated with "off-label" implants. The most frequent "on-label" adverse events were similar to those described in the prospective trials including stent fracture (n=210) and endocarditis (n=104). Previously unrecognised or under-recognised adverse events included stent fragment embolisation (n=5), device erosion (n=4), immediate post-implant severe valvar insufficiency (n=2), and late coronary compression (n=2 cases at 5 days and 3 months after implantation). Under-recognised adverse events associated with off-label implantation included early valve failure due to insufficiency when implanted in the tricuspid position (n=7) and embolisation with percutaneous implantation in the mitral position (n=5). Post-market passive surveillance does not demonstrate a high frequency of previously unrecognised serious adverse events with "on-label" Melody® valve implantation. Further study is needed to evaluate safety of "off-label" uses.

  19. Investigation into Equivalency of Synthetic Test Circuit Used for Operational Tests of Thyristor Valves for UHVDC

    Institute of Scientific and Technical Information of China (English)

    ZHOU Hui-gao; YANG Xiao-hui; XU Fan

    2012-01-01

    With the growth of capacity of high voltage direct current (HVDC) transmission lines,the ratings of thyristor valves,which are one of the most critical equipments,are getting higher and higher.Verification of performance of thyristor valves particularly designed for HVDC project plays an important role in the handover of products between the manufacturer and the client.Conventional test facilities based on philosophy of direct test cannot meet the requirements for modern thyristor valves.New test facilities with high ratings are necessarily built based on philosophy of synthetic test.Over the conventional direct test circuit,the later is an economical and feasible solution with less financial investment and higher test capability.However,the equivalency between the synthetic test and the direct test should be analyzed technically in order to make sure that the condition of verification test in a synthetic test circuit should satisfy the actual operation condition of thyristor valves existing in a real HVDC project,just as in a direct test circuit.Equivalency analysis is focused in this paper,covering the scope of thyristor valves' steady state,and transient state.On the basis of the results achieved,a synthetic test circuit of 6 500 A/50 kV for operational tests of thyristor valves used for up to UHVDC project has newly been set up and already put into service in Xi'an High Voltage Apparatus Research Institute Co.,Ltd. (XIHARI),China.Some of the results have been adopted also by a new national standard of China.

  20. Whitey SCHe Ball Valves Provide Test Port Isolation

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  1. 49 CFR 192.181 - Distribution line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution line valves. 192.181 Section 192.181... line valves. (a) Each high-pressure distribution system must have valves spaced so as to reduce the time to shut down a section of main in an emergency. The valve spacing is determined by the...

  2. 46 CFR 105.25-20 - Shutoff valves required.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Shutoff valves required. 105.25-20 Section 105.25-20... Installed Below Decks § 105.25-20 Shutoff valves required. (a) Shutoff valves shall be provided in the suction lines as close to the tanks as possible. The valves shall be installed so as to shut off...

  3. 46 CFR 154.1125 - Pipes, fittings, and valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pipes, fittings, and valves. 154.1125 Section 154.1125... Firefighting § 154.1125 Pipes, fittings, and valves. (a) Each pipe, fitting, and valve for each water spray... listed in § 154.1110 must have at least one isolation valve at each branch connection and at least...

  4. 46 CFR 154.806 - Capacity of pressure relief valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Capacity of pressure relief valves. 154.806 Section 154... Equipment Cargo Vent Systems § 154.806 Capacity of pressure relief valves. Pressure relief valves for each... pressure above the set pressure of the relief valves: (a) The maximum capacity of an installed cargo...

  5. 46 CFR 78.17-5 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.17-5 Section 78.17-5..., Drills, and Inspections § 78.17-5 Valves and closing appliances. (a) It shall be the duty of the master to see that all valves, including cross connecting valves where fitted, and other appliances such...

  6. 46 CFR 153.368 - Pressure-vacuum valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve... relief valve must meet the requirements of Subpart 162.017 of this chapter....

  7. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Valves, fittings, and accessories. 98.25-40 Section 98... Anhydrous Ammonia in Bulk § 98.25-40 Valves, fittings, and accessories. (a) All valves, flanges, fittings... Engineering) of this chapter. Valves shall be fitted with noncorrosive material suitable for ammonia...

  8. 46 CFR 56.20-9 - Valve construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve construction. 56.20-9 Section 56.20-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Valves § 56.20-9 Valve construction. (a) Each valve must close with a right-hand...

  9. Additive Manufactured Product Integrity

    Science.gov (United States)

    Waller, Jess; Wells, Doug; James, Steve; Nichols, Charles

    2017-01-01

    NASA is providing key leadership in an international effort linking NASA and non-NASA resources to speed adoption of additive manufacturing (AM) to meet NASA's mission goals. Participants include industry, NASA's space partners, other government agencies, standards organizations and academia. Nondestructive Evaluation (NDE) is identified as a universal need for all aspects of additive manufacturing.

  10. Modern manufacturing engineering

    CERN Document Server

    2015-01-01

    This book covers recent research and trends in Manufacturing Engineering. The chapters emphasize different aspects of the transformation from materials to products. It provides the reader with fundamental materials treatments and the integration of processes. Concepts such as green and lean manufacturing are also covered in this book.

  11. Strategic Roles of Manufacturing

    DEFF Research Database (Denmark)

    Yang, Cheng

    are accordingly elaborated to address the identified theoretical gaps: • Regarding manufacturing role, the first initial research question is still taken as the starting point, but specific attention is paid on: (1) exploring empirical evidence on the proactive role of manufacturing and investigate how...

  12. Improving Project Manufacturing Coordination

    Directory of Open Access Journals (Sweden)

    Korpivaara Ville

    2014-09-01

    Full Text Available The objective of this research is to develop firms’ project manufacturing coordination. The development will be made by centralizing the manufacturing information flows in one system. To be able to centralize information, a deep user need assessment is required. After user needs have been identified, the existing system will be developed to match these needs. The theoretical background is achieved through exploring the literature of project manufacturing, development project success factors and different frameworks and tools for development project execution. The focus of this research is rather in customer need assessment than in system’s technical expertise. To ensure the deep understanding of customer needs this study is executed by action research method. As a result of this research the information system for project manufacturing coordination was developed to respond revealed needs of the stakeholders. The new system improves the quality of the manufacturing information, eliminates waste in manufacturing coordination processes and offers a better visibility to the project manufacturing. Hence it provides a solid base for the further development of project manufacturing.

  13. Appraising manufacturing location

    NARCIS (Netherlands)

    Steenhuis, Harm-Jan; Bruijn, de Erik J.

    2002-01-01

    International location of manufacturing activities is an issue for managers of manufacturing companies as well as public policy makers. For managers, the issue is relevant because international locations offer opportunities for lowering costs due to productivity improvements. For governments the iss

  14. Assessing manufacturing location

    NARCIS (Netherlands)

    Steenhuis, Harm-Jan; Bruijn, de Erik J.

    2004-01-01

    International location of manufacturing activities is an issue for managers of manufacturing companies as well as public policy-makers. For managers, the issue is relevant because international locations offer opportunities for lowering costs due to productivity improvements. For governments the iss

  15. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  16. Heart Valve Biomechanics and Underlying Mechanobiology

    Science.gov (United States)

    Ayoub, Salma; Ferrari, Giovanni; Gorman, Robert C.; Gorman, Joseph H.; Schoen, Frederick J.; Sacks, Michael S.

    2017-01-01

    Heart valves control unidirectional blood flow within the heart during the cardiac cycle. They have a remarkable ability to withstand the demanding mechanical environment of the heart, achieving lifetime durability by processes involving the ongoing remodeling of the extracellular matrix. The focus of this review is on heart valve functional physiology, with insights into the link between disease-induced alterations in valve geometry, tissue stress, and the subsequent cell mechanobiological responses and tissue remodeling. We begin with an overview of the fundamentals of heart valve physiology and the characteristics and functions of valve interstitial cells (VICs). We then provide an overview of current experimental and computational approaches that connect VIC mechanobiological response to organ- and tissue-level deformations and improve our understanding of the underlying functional physiology of heart valves. We conclude with a summary of future trends and offer an outlook for the future of heart valve mechanobiology, specifically, multiscale modeling approaches, and the potential directions and possible challenges of research development. PMID:27783858

  17. Safety/relief-valve test program

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, J.A.

    1982-01-01

    In response to the NRC's Task 2.1.2 following the TMI-2 accident, government and industry programs were formulated to address the performance of safety and relief valve systems for pressurized and boiling water reactors. Objective is to demonstrate by testing and analysis that safety and relief valve systems in the reactor coolant system are qualified for the anticipated full range of reactor operating and accident conditions. The EPRI PWR program tested PWR safety valves and power operated relief valves (PORVs) under steam, liquid, and steam/liquid transition conditions. The program also tested PWR PORV block valves under steam conditions. The GE BWR program tested BWR relief and safety/relief valves under high pressure steam and low pressure liquid conditions. EG and G Idaho recent activities have focused on the evaluation of the industry test data, evaluation and modification of analytical codes for safety/relief valve system analysis, and initial evaluation of utility responses to US NRC program requirements.

  18. A multicentre comparative evaluation of catheter valves.

    Science.gov (United States)

    Fader, M; Pettersson, L; Brooks, R; Dean, G; Wells, M; Cottenden, A; Malone-Lee, J

    Catheter valves are an alternative to leg bags for urine drainage, but no studies have yet been published which have compared the performance of different valves. This study was undertaken to evaluate the performance of the seven catheter valves available on the UK market in April 1996. The study was carried out by the Continence Products Evaluation (CPE) Network funded by the Medical Devices Agency (Department of Health). Each valve type was tested for 1 week by 19-36 cognitively unimpaired and manually dextrous subjects recruited from 11 test centres. At the end of each week, subjects completed an evaluation form (based on a three-point rating scale) to record product performance. The same catheter valves were also tested for ease of opening/closing by 33 subjects (mostly catheter users) who had some manual impairment. Performance scores varied widely between products. It was found that, to be successful, a valve needs to be easy to manipulate, leak-free, comfortable and inconspicuous. Prescribers need to be aware of the strengths and limitations of different valves for appropriate product selection.

  19. Are valve repairs associated with better outcomes than replacements in patients with native active valve endocarditis?

    Science.gov (United States)

    Zhao, Dong; Zhang, Benqing

    2014-12-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether valve replacement was associated with higher morbidity and mortality rates than valve repair in patients with native active valve endocarditis. Altogether 662 papers were found using the reported search, of which 7 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Traditionally, valve replacement has been the standard therapy for valve endocarditis when surgical treatment is indicated. But now valve repair is increasingly used as an alternative, which may avoid disadvantages of anticoagulation, lower the risk of prosthetic infection and improve postoperative survival. To compare outcomes of these two treatments between studies can be difficult because most of related papers contain raw data on prosthetic valve endocarditis or healed endocarditis, which were excluded from our manuscript. Studies only analysing the outcomes of either of these treatments without the comparison of valve repair and replacement were also excluded. Finally, seven papers were identified. The American Heart Association/American College of Cardiology 2006 valvular guidelines recommended that mitral valve repair should be performed instead of replacement when at all possible. In three of the seven studies, there were significant differences between valve repair and replacement in long-term survival. One study found that aortic valve repair offered better outcomes in freedom from reoperation at 5 years (P = 0.021) and in survival at 4 years (repair vs replacement 88 vs 65%; P = 0.047). One study reported that there was improved event-free survival at 10 years in the mitral valve repair group (P = 0.015), although there was more previous septic embolization in this group. In one study, early and late mortality

  20. Optimized manufacturable porous materials

    DEFF Research Database (Denmark)

    Andreassen, Erik; Andreasen, Casper Schousboe; Jensen, Jakob Søndergaard

    Topology optimization has been used to design two-dimensional material structures with specific elastic properties, but optimized designs of three-dimensional material structures are more scarsely seen. Partly because it requires more computational power, and partly because it is a major challenge...... to include manufacturing constraints in the optimization. This work focuses on incorporating the manufacturability into the optimization procedure, allowing the resulting material structure to be manufactured directly using rapid manufacturing techniques, such as selective laser melting/sintering (SLM....../S). The available manufacturing methods are best suited for porous materials (one constituent and void), but the optimization procedure can easily include more constituents. The elasticity tensor is found from one unit cell using the homogenization method together with a standard finite element (FE) discretization...

  1. A novel implantable glaucoma valve using ferrofluid.

    Directory of Open Access Journals (Sweden)

    Eleftherios I Paschalis

    Full Text Available PURPOSE: To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. SETTING: Massachusetts Eye & Ear Infirmary, Boston, USA. METHODS: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. RESULTS: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg. X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. CONCLUSIONS: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.

  2. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  3. Film edge nonlocal spin valves.

    Science.gov (United States)

    McCallum, Andrew T; Johnson, Mark

    2009-06-01

    Spintronics is a new paradigm for integrated digital electronics. Recently established as a niche for nonvolatile magnetic random access memory (MRAM), it offers new functionality while demonstrating low-power and high-speed performance. However, to reach high density spintronic technology must make a transition to the nanometer scale. Prototype devices are presently made using a planar geometry and have an area determined by the lithographic feature size, currently about 100 nm. Here we present a new nonplanar geometry in which one lateral dimension is given by a film thickness, on the order of 10 nm. With this new approach, cell sizes can shrink by an order of magnitude. The geometry is demonstrated with a nonlocal spin valve, where we study devices with an injector/detector separation much less than the spin diffusion length.

  4. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  5. Valve Corporation: Composing Internal Markets

    Directory of Open Access Journals (Sweden)

    Todd R. Zenger

    2015-07-01

    Full Text Available Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be asked of Google’s unusual organizational approach. Is Google’s success the result of its extensive autonomy granted to employees, or is its past success the enabling cause of such autonomy? Such questions, of course, are empirically unanswerable here. I therefore set them aside and assume this organizational specimen is efficient – well-suited to its environment – and proceed with further commentary.

  6. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  7. Bacillus cereus endocarditis in native aortic valve.

    Science.gov (United States)

    Ngow, H A; Wan Khairina, W M N

    2013-02-01

    Bacillus cereus endocarditis is rare. It has been implicated in immunocompromised individuals, especially in intravenous drug users as well as in those with a cardiac prosthesis. The patient was a 31-year-old ex-intravenous drug addict with a past history of staphylococcal pulmonary valve endocarditis, who presented with symptoms of decompensated cardiac failure. Echocardiography showed severe aortic regurgitation with an oscillating vegetation seen on the right coronary cusp of the aortic valve. The blood cultures grew Bacillus cereus. We report this as a rare case of Bacillus cereus endocarditis affecting a native aortic valve.

  8. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations may...... be atypical causing a delay in the diagnosis and treatment. The management is also complicated by their comorbidities, and surgical treatment may not be feasible leading to a significant morbidity and mortality. We describe a case of an 85-year-old man with TAVI prosthetic valve endocarditis successfully...

  9. The echocardiography of replacement heart valves

    Science.gov (United States)

    2016-01-01

    This is a practical description of how replacement valves are assessed using echocardiography. Normal transthoracic appearances including normal variants are described. The problem of differentiating normal function, patient–prosthesis mismatch and pathological obstruction in aortic replacement valves with high gradients is discussed. Obstruction and abnormal regurgitation is described for valves in the aortic, mitral and right-sided positions and when to use echocardiography in suspected infective endocarditis. The roles of transoesophageal and stress echocardiography are described and finally when other imaging techniques may be useful. PMID:27600454

  10. Combined pressure regulator and shutoff valve

    Science.gov (United States)

    Koch, E. F. (Inventor)

    1974-01-01

    A remotely operable pressure regulator and shutoff valve particularly suited for achieving high resolution and flow control, and positive shutoff is described. The valve is characterized by a spring-loaded ball coaxially aligned with a fluid port to be sealed, a spring-loaded pintle extended through the port into engagement with the ball, for controlling the position, a spring-loaded diaphragm for controlling the position of the pintle, and an axially displaceable spring supported by a movable stop which, in turn, is repositioned by a selectively operable stepper motor. Thus, the pressure-response characteristics for the valve can be varied through a selective repositioning of the stop.

  11. [New aspects in aortic valve disease].

    Science.gov (United States)

    Tornos, P

    2001-01-01

    Renewed interest for aortic valve disease has evolved in recent years. Aortic valve replacement has become the second most frequent cause of cardiac surgery, following coronary bypass surgery. In addition, the etiologic and physiopathologic knowledge of this disorder has improved. In the present paper we analyze three aspects of the disease which are, at present, the subject of study and controversy: first, we discuss the possible relationship between degenerative aortic stenosis and atherosclerosis; second, the involvement of the aortic root in cases of bicuspid aortic valve; and third, the surgical indications in asymptomatic patients with either aortic stenosis or regurgitation.

  12. Three-dimensional echocardiography in valve disease.

    Science.gov (United States)

    Colombo, Chiara; Tamborini, Gloria; Pepi, Mauro; Alimento, Marina; Fiorentini, Cesare

    2007-01-01

    This review covers the role of three-dimensional (3D) echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic) and quantitative advantages of this technique.

  13. Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating

    Science.gov (United States)

    Casada, Donald A.

    1996-01-01

    A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization.

  14. Antimicrobial Peptides in Biomedical Device Manufacturing

    Directory of Open Access Journals (Sweden)

    Martijn Riool

    2017-08-01

    Full Text Available Over the past decades the use of medical devices, such as catheters, artificial heart valves, prosthetic joints, and other implants, has grown significantly. Despite continuous improvements in device design, surgical procedures, and wound care, biomaterial-associated infections (BAI are still a major problem in modern medicine. Conventional antibiotic treatment often fails due to the low levels of antibiotic at the site of infection. The presence of biofilms on the biomaterial and/or the multidrug-resistant phenotype of the bacteria further impair the efficacy of antibiotic treatment. Removal of the biomaterial is then the last option to control the infection. Clearly, there is a pressing need for alternative strategies to prevent and treat BAI. Synthetic antimicrobial peptides (AMPs are considered promising candidates as they are active against a broad spectrum of (antibiotic-resistant planktonic bacteria and biofilms. Moreover, bacteria are less likely to develop resistance to these rapidly-acting peptides. In this review we highlight the four main strategies, three of which applying AMPs, in biomedical device manufacturing to prevent BAI. The first involves modification of the physicochemical characteristics of the surface of implants. Immobilization of AMPs on surfaces of medical devices with a variety of chemical techniques is essential in the second strategy. The main disadvantage of these two strategies relates to the limited antibacterial effect in the tissue surrounding the implant. This limitation is addressed by the third strategy that releases AMPs from a coating in a controlled fashion. Lastly, AMPs can be integrated in the design and manufacturing of additively manufactured/3D-printed implants, owing to the physicochemical characteristics of the implant material and the versatile manufacturing technologies compatible with antimicrobials incorporation. These novel technologies utilizing AMPs will contribute to development of novel

  15. Antimicrobial Peptides in Biomedical Device Manufacturing.

    Science.gov (United States)

    Riool, Martijn; de Breij, Anna; Drijfhout, Jan W; Nibbering, Peter H; Zaat, Sebastian A J

    2017-01-01

    Over the past decades the use of medical devices, such as catheters, artificial heart valves, prosthetic joints, and other implants, has grown significantly. Despite continuous improvements in device design, surgical procedures, and wound care, biomaterial-associated infections (BAI) are still a major problem in modern medicine. Conventional antibiotic treatment often fails due to the low levels of antibiotic at the site of infection. The presence of biofilms on the biomaterial and/or the multidrug-resistant phenotype of the bacteria further impair the efficacy of antibiotic treatment. Removal of the biomaterial is then the last option to control the infection. Clearly, there is a pressing need for alternative strategies to prevent and treat BAI. Synthetic antimicrobial peptides (AMPs) are considered promising candidates as they are active against a broad spectrum of (antibiotic-resistant) planktonic bacteria and biofilms. Moreover, bacteria are less likely to develop resistance to these rapidly-acting peptides. In this review we highlight the four main strategies, three of which applying AMPs, in biomedical device manufacturing to prevent BAI. The first involves modification of the physicochemical characteristics of the surface of implants. Immobilization of AMPs on surfaces of medical devices with a variety of chemical techniques is essential in the second strategy. The main disadvantage of these two strategies relates to the limited antibacterial effect in the tissue surrounding the implant. This limitation is addressed by the third strategy that releases AMPs from a coating in a controlled fashion. Lastly, AMPs can be integrated in the design and manufacturing of additively manufactured/3D-printed implants, owing to the physicochemical characteristics of the implant material and the versatile manufacturing technologies compatible with antimicrobials incorporation. These novel technologies utilizing AMPs will contribute to development of novel and safe

  16. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  17. Euler force actuation mechanism for siphon valving in compact disk-like microfluidic chips.

    Science.gov (United States)

    Deng, Yongbo; Fan, Jianhua; Zhou, Song; Zhou, Teng; Wu, Junfeng; Li, Yin; Liu, Zhenyu; Xuan, Ming; Wu, Yihui

    2014-03-01

    Based on the Euler force induced by the acceleration of compact disk (CD)-like microfluidic chip, this paper presents a novel actuation mechanism for siphon valving. At the preliminary stage of acceleration, the Euler force in the tangential direction of CD-like chip takes the primary place compared with the centrifugal force to function as the actuation of the flow, which fills the siphon and actuates the siphon valving. The Euler force actuation mechanism is demonstrated by the numerical solution of the phase-field based mathematical model for the flow in siphon valve. In addition, experimental validation is implemented in the polymethylmethacrylate-based CD-like microfluidic chip manufactured using CO2 laser engraving technique. To prove the application of the proposed Euler force actuation mechanism, whole blood separation and plasma extraction has been conducted using the Euler force actuated siphon valving. The newly introduced actuation mechanism overcomes the dependence on hydrophilic capillary filling of siphon by avoiding external manipulation or surface treatments of polymeric material. The sacrifice for highly integrated processing in pneumatic pumping technique is also prevented by excluding the volume-occupied compressed air chamber.

  18. Correlation between structural changes and acute thrombogenicity in transcatheter pericardium valves after crimping and balloon deployment.

    Science.gov (United States)

    Bourget, J-M; Zegdi, R; Lin, J; Wawryko, P; Merhi, Y; Convelbo, C; Mao, J; Fu, Y; Xu, T; Merkel, N O; Wang, L; Germain, L; Zhang, Z; Guidoin, R

    2017-03-01

    Transcathether heart valve replacement has gained considerable acceptance during the last decades. It is now part of the armamentarium for aortic valve replacement. The procedure proved to be highly efficient. However the issues of the blood compatibility and tissue durability were not raised and the adverse events were probably under-reported, according to observations of thrombosis after deployment. Bovine pericardium leaflets were sewn inside a 26mm diameter stainless steel stent to manufacture these valves (one control and two experimental). The correlation between the trauma and the acute thombogenicity of bovine pericardium leaflets, after crimping and ballooning, was investigated via an in vitro blood flow with labeled platelets. These leaflets were processed for histology: scanning electron microscopy, light microscopy, and transmission electron microscopy. The control specimens showed a regular pericardium structure with some blood cells deposited on the collagen fibrous surface (inflow) and scarce blood cells deposited on the serous surface (outflow). After crimping and ballooning, the structure of the pericardium was severely injured, eventually with delaminations and ruptures. The blood cell uptake was considerably increased compared to the control. It would therefore be appropriate to pay more attention to the design of the valves. Specifically, the incorporation of a buffer tissue or fabric between the pericardium and the metallic stent is suggested. The issue of ballooning deserves detailed and in depth investigation regarding the lifetime of the device. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Control performances of a piezoactuator direct drive valve system at high temperatures with thermal insulation

    Science.gov (United States)

    Han, Yung-Min; Han, Chulhee; Kim, Wan Ho; Seong, Ho Yong; Choi, Seung-Bok

    2016-09-01

    This technical note presents control performances of a piezoactuator direct drive valve (PDDV) operated at high temperature environment. After briefly discussing operating principle and mechanical dimensions of the proposed PDDV, an appropriate size of the PDDV is manufactured. As a first step, the temperature effect on the valve performance is experimentally investigated by measuring the spool displacement at various temperatures. Subsequently, the PDDV is thermally insulated using aerogel and installed in a large-size heat chamber in which the pneumatic-hydraulic cylinders and sensors are equipped. A proportional-integral-derivative feedback controller is then designed and implemented to control the spool displacement of the valve system. In this work, the spool displacement is chosen as a control variable since it is directly related to the flow rate of the valve system. Three different sinusoidal displacements with different frequencies of 1, 10 and 50 Hz are used as reference spool displacement and tracking controls are undertaken up to 150 °C. It is shown that the proposed PDDV with the thermal insulation can provide favorable control responses without significant tracking errors at high temperatures.

  20. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  1. Artificial SMA valve for treatment of urinary incontinence: upgrading of valve and introduction of transcutaneous transformer.

    Science.gov (United States)

    Tanaka, M; Hirano, K; Goto, H; Namima, T; Uchi, K; Jiang, Z W; Matsuki, H; Tanahashi, Y; Orikasa, S; Chonan, S

    1999-01-01

    This paper is concerned with the development of an artificial urethral valve driven by shape memory alloy actuators, which is attached onto the urethra of a urinary incontinence sufferer for treating the involuntary micturition. Three types of compact cylindrical valves are assembled and their opening and closing functions are examined experimentally. The updated valve is heated and opened by using the transcutaneous energy transformer consisting of a pair of flexible spiral-formed copper wire coils. The experiment using the canine urinary canal verifies that the total system of the valve and the transformer works well as an artificial sphictor muscle and controls the urinary flow through the canal appropriately.

  2. [Emergent transcatheter aortic valve implantation in a patient with bicuspid aortic valve stenosis in cardiogenic shock].

    Science.gov (United States)

    Pizzighini, S; Finet, G; Obadia, J-F; Revel, D; Bresson, D; Rioufol, G

    2015-02-01

    Transcatheter aortic valve implantation is a therapeutic option for high-risk patients with severe aortic valve stenosis and with cardiac symptoms. This procedure requires the preliminary evaluation by a "heart team" and presents some contraindications. We report the case of a 58-year-old man with severe bicuspid aortic valve stenosis and cardiogenic shock. In spite of contraindications and because of the failure of balloon aortic valvuloplasty, transcatheter aortic valve implantation was performed in emergency. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  3. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  4. Experimental study on wear failure course of gas-valve/valve-seat in engine

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yun-cai; YAN Hang-zhi

    2005-01-01

    The wear failure course of gas-valve/valve-seat in engine was investigated with a simulating tester. The results show that the failure of the contact conical surface is mainly caused by the elastic and plastic deformation and the fatigue micro-crack and spalling. The creep-deformation and corrosion atmosphere accelerated wear failure course at the high temperature. The wear failure course of the gas-valve/valve-seat in engine follows general wear rules of mechanical elements, but the rate of wear in the sharp wear stage is faster.

  5. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    Science.gov (United States)

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  6. Mitral Valve Replacement with a Mechanical Valve for Severe Mitral Regurgitation in a Small Dog

    Directory of Open Access Journals (Sweden)

    Daisuke Taguchi

    2014-01-01

    Full Text Available A seven-year-old Shih Tzu with refractory repeated pulmonary edema and syncope was presented for surgical operation. From the results of cardiovascular examinations, the dog was diagnosed as severe mitral regurgitation (ACVIM consensus class D and mild tricuspid regurgitation. The dog first underwent surgery with mitral valve plasty; however, the results were unsatisfactory due to severe damage of the whole mitral valve. The operation was quickly changed to mitral valve replacement using a mechanical valve (19 mm. The dog survived surgery and lived for 2 years and one month after operation using long-term anticoagulant (warfarin therapy in spite of several thrombosis-related events.

  7. Modelos de crescimento resultantes da combinação e variações dos modelos de Chapman-Richards e Silva-Bailey aplicados em Leucaena leucocephala (Lam. de Wit.

    Directory of Open Access Journals (Sweden)

    Cícero Carlos Ramos de Brito

    2010-08-01

    Full Text Available O objetivo deste trabalho foi desenvolver novos modelos de crescimento para recursos florestais aplicados à leucena [Leucaena leucocephala (Lam. de Wit], tendo como base as hipóteses biológicas propostas por Chapman-Richards e Silva-Bailey. O experimento de leucena foi conduzido na Estação Experimental da Empresa Pernambucana de Pesquisa Agropecuária - IPA, Caruaru, PE. Foram utilizadas 544 árvores de leucena de um experimento com vinte remedições realizadas ao longo de 12 anos. Compararam-se novos modelos de crescimento resultantes da combinação e variações dos modelos de Chapman-Richards e Silva-Bailey, bem como outros comumente usados em recursos florestais. Para a seleção das equações, utilizaram-se o Índice de Ajuste (IA, o erro-padrão da estimativa e a distribuição gráfica dos resíduos. Os resultados indicaram que todos os modelos testados se ajustaram de maneira satisfatória aos dados, podendo ser utilizados para se estimar o crescimento em altura da leucena.

  8. Competitive Manufacturing Dynamics

    DEFF Research Database (Denmark)

    Rymaszewska, Anna; Christensen, Irene; Karlsson, Christer

    The increasing complexity of business environments and the pressure for organizations on delivering new products faster while maintaining the superior quality of their products, has forced manufacturing organizations to rethink their operations. Managers responsible for manufacturing ramp-up need...... to constantly improve this process in terms of time to volume, according to predefined cost and quality measures. The importance of the success of this process can lead to a significant creation of competitive advantage. This paper addresses the challenges of the manufacturing ramp-up process in the context...

  9. Competitive Manufacturing Dynamics

    DEFF Research Database (Denmark)

    Rymaszewska, Anna; Christensen, Irene; Karlsson, Christer

    The increasing complexity of business environments and the pressure for organizations on delivering new products faster while maintaining the superior quality of their products, has forced manufacturing organizations to rethink their operations. Managers responsible for manufacturing ramp-up need...... to constantly improve this process in terms of time to volume, according to predefined cost and quality measures. The importance of the success of this process can lead to a significant creation of competitive advantage. This paper addresses the challenges of the manufacturing ramp-up process in the context...... of lean improvements as well as organizational learning....

  10. Basis of valve operator selection for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. S.; Lee, D. J.; See, J. K.; Park, C. K.; Choi, B. S

    2000-05-01

    SMART, an integral reactor with enhanced safety and operability, is under development for use of the nuclear energy. The valve operator of SMART system were selected through the data survey and technical review of potential valve fabrication vendors, and it will provide the establishment and optimization of the basic system design of SMART. In order to establish and optimize the basic system design of SMART, the basis of selection for the valve operator type were provided based on the basic design requirements. The basis of valve operator selection for SMART will be used as a basic technical data for the SMART basic and detail design and a fundamental material for the new reactor development in the future.

  11. Valve Technology Arrangement of Cryopump: A Review

    Directory of Open Access Journals (Sweden)

    Sanjiv Y. Rajput

    2014-05-01

    Full Text Available A cryopump or a "cryogenic pump" is a vacuum pump that pumps the trap gases and vapours by condensing them on a cold surface. Helium gas which is very light can only be pumped by Cryopump. Cryopump cannot be used when working for continuous operation as it pumps the effluent till the saturation state is achieved. Then the absorbed gases are to be collected through other mechanical pump through regeneration process. Hence, valve technology arrangement is incorporated with the cryopump in order to achieve the continuous pumping when two cryopump are used in alternate processes (i.e. absorption and regeneration. Various design of Valve technology arrangement is proposed by different researcher all over the world. This review paper focuses on the different proposed valve technology arrangement and elaborately explains the various components of valve technology and concludes the best possible arrangement that can be used in Cryopump.

  12. Heritable retinoblastoma and accelerated aortic valve disease

    Science.gov (United States)

    Abeyratne, L R; Kingston, J E; Onadim, Z; Dubrey, S W

    2013-01-01

    Heritable retinoblastoma is associated with a germline mutation in the tumour suppressor gene RBI. The Rb protein (pRb) arises from the RB1 gene, which was the first demonstrated cancer susceptibility gene in humans. 1 Second primary malignancies are recognised complications of retinoblastoma. Furthermore, pRb is implicated in valve remodelling in calcific aortic valve disease. 2 3 We report a family with hereditary retinoblastoma and associated secondary primary malignancies. There are two interesting aspects to this family. The first is the concept of ‘cancer susceptibility genes’; the RBI gene being the first reported in humans. A further feature of note is that two family members also have bicuspid aortic valves. We discuss a potential association between the gene defect responsible for retinoblastoma (with its associated propensity for further malignancies) and accelerated deterioration of the bicuspid aortic valve in the proband carrying this gene defect. PMID:23595191

  13. Simulation of a Hydraulic Pump Control Valve

    Science.gov (United States)

    Molen, G. Vander; Akers, A.

    1987-01-01

    This paper describes the mode of operation of a control valve assembly that is used with a hydraulic pump. The operating system of the valve is modelled in a simplified form, and an analogy for hydraulic resonance of the pressure sensing system is presented. For the control valve investigated, air entrainment, length and diameter of the resonator neck, and valve mass produced the greatest shift in resonant frequency. Experimental work was conducted on the hydraulic system so that the resonance levels and frequencies could be measured and the accuracy of the theory verified. The results obtained make it possible to evaluate what changes to any of the variables considered would be most effective in driving the second harmonic frequency above the operating range.

  14. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  15. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cryogenic flow-control valve based on Venturi-Offset Technology (VOST) will be designed and modeled. VOST provides precise linear flow control within a...

  16. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cylindrical, low-mass, high-efficiency, leak-proof cryogenic valve will be designed using composites and exotic metals. Based upon cryogenically-proven Venturi...

  17. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two cryogenic flow-control valves of diameters 1/2" and 2" will be built and tested. Based on cryogenically-proven Venturi Off-Set Technology (VOST) they have no...

  18. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  19. Contamination avoidance devices for poppettype shutoff valves

    Science.gov (United States)

    Endicott, D. L.

    1973-01-01

    The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.

  20. Surgical Treatment of Congenital Mitral Valve Dysplasia.

    Science.gov (United States)

    Vida, Vladimiro L; Carrozzini, Massimiliano; Padalino, Massimo; Milanesi, Ornella; Stellin, Giovanni

    2016-05-01

    Congenital mitral valve (MV) dysplasia is a relatively rare and highly complex cardiac disease. We present our results and illustrate the techniques used to repair these valves. Between 1972 and 2014, 100 consecutive patients underwent surgical repair of congenital MV dysplasia at our institution. Predominant MV regurgitation was present in 53 patients (53%) whereas mitral stenosis was prevalent in 47 (47%). There were five early (5%) and eight late deaths (9%). Actuarial survival was 95%, 94%, and 93% at 5, 10, and 20 years, respectively. Sixteen patients (18%) required reintervention due to subsequent MV dysfunction. Actuarial freedom from reintervention for MV dysfunction was 95%, 92%, and 89% at 5, 10, and 20 years, respectively. The mechanism underlying the valve dysfunction in congenital mitral valve dysplasia is multifactorial and requires the application of a variety of surgical techniques for repair. doi: 10.1111/jocs.12743 (J Card Surg 2016;31:352-356). © 2016 Wiley Periodicals, Inc.

  1. Electrodynamic actuators for rocket engine valves

    Science.gov (United States)

    Fiet, O.; Doshi, D.

    1972-01-01

    Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.

  2. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  3. Percutaneous Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

    Science.gov (United States)

    Malhotra, Rohit; Sharma, Anjali; Kakouros, Nikolaos

    2017-01-01

    Percutaneous transcatheter tricuspid balloon valvuloplasty (PTTBV) is an accepted treatment option for symptomatic severe native tricuspid valve stenosis, although surgical tricuspid valve replacement remains the treatment of choice. There have been few reports of successful PTTBV for bioprosthetic tricuspid valve stenosis. We present case reports of 3 patients from our hospital experience. Two of the 3 cases were successful, with lasting clinical improvement, whereas the 3rd patient failed to show a reduction in valve gradient. We describe the standard technique used for PTTBV. We present results from a literature review that identified 16 previously reported cases of PTTBV for bioprosthetic severe tricuspid stenosis, with overall favorable results. We conclude that PTTBV should perhaps be considered for a select patient population in which symptomatic improvement and hemodynamic stability are desired immediately, and particularly for patients who are inoperable or at high surgical risk.

  4. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  5. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness d

  6. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  7. Transcatheter Aortic Valve Replacement in a Patient With a Previous Bioprosthetic Mitral Valve Replacement: Report of a Delayed Fatal Interaction.

    Science.gov (United States)

    Poulin, Frédéric; Lamarche, Yoan; Le, Van Hoai Viet; Doucet, Michel; Roméo, Philippe; Généreux, Philippe

    2016-02-01

    We report on a man with bioprosthetic mitral valve perforation who presented late after transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve (THV). The protrusion of the commissural strut of the bioprosthetic mitral valve coupled with the low implanted THV resulted in repetitive trauma leading to rupture of a mitral leaflet. Potential preventive strategies are discussed. This case illustrates the importance of preprocedural imaging screening and cautious THV deployment in patients with a bioprosthetic mitral valve.

  8. Tenecteplase in prosthetic mitral valve thrombosis

    OpenAIRE

    2010-01-01

    In the few reported cases of prosthetic mitral valve thrombosis, where surgical intervention was considered as high risk, fibrinolytic therapy had proved life saving. The authors present clinical, laboratory, and imaging data from such a patient, with prosthetic mitral valve thrombosis and its successful management with tenecteplase. The use of tenecteplase as a viable fibrinolytic agent for the first time was justified, due to the lack of immunogenicity concerns compared to streptokinase.

  9. Tenecteplase in prosthetic mitral valve thrombosis.

    Science.gov (United States)

    Ayyub Ghori, Masood; Bakir, Sherif; Ellahham, Samer; Al Nassir, Adnan; Al Zubaidi, Abdulmajeed; Augustin, Norbert; Abdelaziz, Moataz Ayman; Turrin, Nicolas Patrick; Al Mahmeed, Wael Abdulrahman

    2011-04-01

    In the few reported cases of prosthetic mitral valve thrombosis, where surgical intervention was considered as high risk, fibrinolytic therapy had proved life saving. The authors present clinical, laboratory, and imaging data from such a patient, with prosthetic mitral valve thrombosis and its successful management with tenecteplase. The use of tenecteplase as a viable fibrinolytic agent for the first time was justified, due to the lack of immunogenicity concerns compared to streptokinase.

  10. Symptomatic papillary tumour of the pulmonary valve

    OpenAIRE

    Cooper, Linda Carol

    1982-01-01

    Papillary ‘tumours’ are small pedunculated lesions of the valve cusps and result from wear-and-tear. They are therefore frequent post-mortem findings in older patients. The vast majority are clinically silent, though occasionally such lesions when on the aortic valve may produce symptoms of myocardial or cerebral ischaemia. None has been known to cause symptoms when in the right side of the heart.

  11. Reconstructive surgery of the aortic valve

    Directory of Open Access Journals (Sweden)

    Mendonça José Teles de

    2003-01-01

    Full Text Available OBJECTIVE: Lacking an ideal valve substitute and motivated by the good results of mitral valve repair since 1990, we faced with determination aortic valve reconstruction surgery. The objective of this paper is to show our experience with this procedure. METHOD: Between January of 1990 and December of 2001; 136 aortic valve repair surgeries were performed. Seventy-five (55.1% of the patients were female and the ages ranged from 4 to 70 years (mean 23.3 ± 1.2 years. Every patient had rheumatic valve disease and insufficiency was the most prevalent type (108 patients - 79.4%, followed by double aortic lesion in 16 (11.7% patients and stenosis in 12 (8.8%. The surgical techniques used were: subcommissural annuloplasty in 74 (54.4% patients, commissurotomy in 38 (27.9%, cusp extension with pericardium in 17 (12.5%, substitution of one cusp in 2 (1.4%, cusp suspension by annuloplasty in 37 (27.2% and Valsalva sinus remodeling in 27 (19.8%. The surgery exclusively involved the aortic valve in 57 (41.9% patients and was associated in 79 (mitral valve replacement in 12, mitral repair in 65, coronary artery bypass grafting in 1 and pulmonary commissurotomy in 1. RESULTS: Hospital mortality was 2.2% and 22 (16.2% patients underwent a new surgery during the follow-up period (57.7 ± 3.5 months. CONCLUSIONS: Aortic valve repair is a safe surgical procedure that can be used in an increasing number of patients with promising results.

  12. DIAGNOSTICS AND TREATMENT OF MITRAL VALVE PROLAPSE

    Directory of Open Access Journals (Sweden)

    D. A. Kuzhel

    2010-01-01

    Full Text Available The mitral valve prolapse (MVP is one of the most inconsistent diagnose. In the most cases patients with MVP have the good long-term prognosis, and therapy is aimed at reduction in psychovegetative dysfunction. Careful follow-up and timely cardiosurgical correction should be performed, if necessary, in patients with classical MPV. The choice method in these cases is the mitral valve plasty.

  13. Fibrinolytic therapy for mechanical pulmonary valve thrombosis.

    Science.gov (United States)

    Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza

    2015-01-01

    Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.

  14. Native valve Escherichia coli endocarditis following urosepsis.

    Science.gov (United States)

    Rangarajan, D; Ramakrishnan, S; Patro, K C; Devaraj, S; Krishnamurthy, V; Kothari, Y; Satyaki, N

    2013-05-01

    Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  15. 75 FR 80040 - Manufacturing Council

    Science.gov (United States)

    2010-12-21

    ... International Trade Administration Manufacturing Council AGENCY: International Trade Administration, U.S... Manufacturing Council. SUMMARY: On November 23, 2010, the Department of Commerce's International Trade... vacant position on the Manufacturing Council (Council). The November 23, 2010 notice provided that all...

  16. 75 FR 30781 - Manufacturing Council

    Science.gov (United States)

    2010-06-02

    ... International Trade Administration Manufacturing Council AGENCY: International Trade Administration, U.S... Manufacturing Council. SUMMARY: On March 16, 2010, the Department of Commerce's International Trade... the Manufacturing Council (Council). The March 16, 2010 notice provided that all applications must be...

  17. Europa Propulsion Valve Seat Material Testing

    Science.gov (United States)

    Addona, Brad M.

    2017-01-01

    The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

  18. 2D DIGITAL SIMPLIFIED FLOW VALVE

    Institute of Scientific and Technical Information of China (English)

    Ruan Jian; Li Sheng; Pei Xiang; Burton R; Ukrainetz P; Bitner D

    2004-01-01

    The 2D digital simplified flow valve is composed of a pilot-operated valve designed with both rotary and linear motions of a single spool,and a stepper motor under continual control.How the structural parameters affect the static and dynamic characteristics of the valve is first clarified and a criterion for stability is presented.Experiments are designed to test the performance of the valve.It is necessary to establish a balance between the static and dynamic characteristics in deciding the structural parameters.Nevertheless,it is possible to maintain the dynamic response at a fairly high level,while keeping the leakage of the pilot stage at an acceptable level.One of the features of the digital valve is stage control.In stage control the nonlinearities,such as electromagnetic saturation and hysteresis,are greatly reduced.To a large extent the dynamic response of the valve is decided by the executing cycle of the control algorithm.

  19. Agile manufacturing concept

    Science.gov (United States)

    Goldman, Steven L.

    1994-03-01

    The initial conceptualization of agile manufacturing was the result of a 1991 study -- chaired by Lehigh Professor Roger N. Nagel and California-based entrepreneur Rick Dove, President of Paradigm Shifts, International -- of what it would take for U.S. industry to regain global manufacturing competitiveness by the early twenty-first century. This industry-led study, reviewed by senior management at over 100 companies before its release, concluded that incremental improvement of the current system of manufacturing would not be enough to be competitive in today's global marketplace. Computer-based information and production technologies that were becoming available to industry opened up the possibility of an altogether new system of manufacturing, one that would be characterized by a distinctive integration of people and technologies; of management and labor; of customers, producers, suppliers, and society.

  20. MEDICAL MANUFACTURING INNOVATIONS

    Directory of Open Access Journals (Sweden)

    Cosma Sorin Cosmin

    2015-02-01

    Full Text Available The purpose of these studies was to improve the design and manufacturing process by selective laser melting, of new medical implants. After manufacturing process, the implants were measured, microscopically and mechanical analyzed. Implants manufactured by AM can be an attractive option for surface coatings to improve the osseointegration process. The main advantages of customized implants made by AM process are: the precise adaptation to the region of implantation, better cosmesis, reduced surgical times and better performance over their generic counterparts. These medical manufacturing changes the way that the surgeons are planning surgeries and engineers are designing custom implant. AM process has eliminated the constraints of shape, size, internal structure and mechanical properties making it possible for fabrication of implants that conform to the physical and mechanical requirements of implantation according to CT images. This article will review some custom implants fabricated in DME using biocompatible titanium.

  1. Manufacturing parabolic mirrors

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The photo shows the construction of a vertical centrifuge mounted on an air cushion, with a precision of 1/10000 during rotation, used for the manufacture of very high=precision parabolic mirrors. (See Annual Report 1974.)

  2. Manufacturing tolerant topology optimization

    DEFF Research Database (Denmark)

    Sigmund, Ole

    2009-01-01

    In this paper we present an extension of the topology optimization method to include uncertainties during the fabrication of macro, micro and nano structures. More specifically, we consider devices that are manufactured using processes which may result in (uniformly) too thin (eroded) or too thick...... (dilated) structures compared to the intended topology. Examples are MEMS devices manufactured using etching processes, nano-devices manufactured using e-beam lithography or laser micro-machining and macro structures manufactured using milling processes. In the suggested robust topology optimization...... approach, under- and over-etching is modelled by image processing-based "erode" and "dilate" operators and the optimization problem is formulated as a worst case design problem. Applications of the method to the design of macro structures for minimum compliance and micro compliant mechanisms show...

  3. Many Manufactured Nanosats Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To achieve the capability to affordably produce scores of nano-spacecraft for envisioned constellation missions, a new manufacturing process is needed to reduce the...

  4. Pulmonary-Valve Replacement in Adults: Results With the Medtronic Freestyle Valve.

    Science.gov (United States)

    Ramanan, Sowmya; Doll, Nicolas; Boethig, Dietmar; Tafer, Nadir; Horke, Alexander; Roques, Xavier; Hemmer, Wolfgang Bruno; Roubertie, François

    2015-09-01

    We used the Medtronic Freestyle valve (Medtronic, Minneapolis, MN) as an orthotopic conduit in pulmonary valve replacement in repaired tetralogy of Fallot and as part of the Ross procedure. Midterm outcomes and hemodynamic status of this conduit were analyzed and performances in both subgroups were compared. From February 2002 to July 2012, 115 Freestyle valves were implanted in 52 patients with tetralogy of Fallot and 63 patients within the Ross procedure. Preoperative and perioperative data were reviewed retrospectively in this bicentric study. Mean age at valve surgery was 37 ± 13 years. Median implanted valve size was 27 mm (21 to 29). Early postoperative mortality was 3.48%. There was 100% follow-up for the survivors at a mean of 4.38 ± 2.52 years. There was 1 case of thromboembolism (0.89%), 6 endocarditis (5.4%), and 9 (7.8%) conduit re-interventions. Echocardiography at discharge and last follow-up showed average peak systolic transvalvular gradients of 12.4 ± 5.1 and 18.7 ± 8.8 mm Hg, respectively. Ten patients had significant proximal anastomotic gradients of greater than 50 mm Hg and 4 moderate conduit regurgitations. Survival was 96.52%. No valve degeneration was seen in 87.82% at 5 years. The only risk factor identified for valve re-intervention was conduit implantation without infundibular hood (p = 0.01 in multivariate analysis). Mid-term data show that Freestyle valves are well suited for pulmonary valve replacement in adults in both categories. The surgical technique used in valve implantation is important to ensure conduit durability. These results and accessibility to the Freestyle valve make this an acceptable alternative to homografts. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Plasma-aided manufacturing

    Science.gov (United States)

    Shohet, J. L.

    1993-12-01

    Plasma-aided manufacturing is used for producing new materials with unusual and superior properties, for developing new chemical compounds and processes, for machining, and for altering and refining materials and surfaces. Plasma-aided manufacturing has direct applications to semiconductor fabrication, materials synthesis, welding, lighting, polymers, anti-corrosion coatings, machine tools, metallurgy, electrical and electronics devices, hazardous waste removal, high performance ceramics, and many other items in both the high-technology and the more traditional industries in the United States.

  6. Additively Manufactured Propulsion System

    OpenAIRE

    Dushku, Matthew; Mueller, Paul

    2012-01-01

    New high-performance, carbon-fiber reinforced polymer material allows additive manufacturing to produce pressure vessels capable of high pressures (thousands of pounds per square inch). This advancement in turn allows integral hybrid propulsion which is revolutionary for both CubeSats and additively-manufactured spacecraft. Hybrid propulsion offers simplicity as compared to bipropellant liquid propulsion, significantly better safety compared to solid or monopropellant hydrazine propulsion, an...

  7. Connecting American Manufacturers (CAM)

    Science.gov (United States)

    2013-09-01

    assessments and analyses focused on identifying the sources and criticality of manufacturing variability on high pressure turbine blade performance...to evaluate manufacturing variability as it relates to overall engine performance, whereas General Electric Aviation focused on airflow efficiency...VizSpace’s web crawlers extract opportunities nightly from various Federal, OEM and public and private sites and match and deliver them to suppliers. As a

  8. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  9. Shape Memory Actuated Normally Open Permanent Isolation Valve

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  10. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  11. New strategic roles of manufacturing

    DEFF Research Database (Denmark)

    Yang, Cheng; Johansen, John; Boer, Harry

    2008-01-01

    This paper aims to view manufacturing from a new angle, and tries to look beyond fit, focus and trade-offs, approaches which may no longer be sufficient for long-term competitive success. Four cases from different industries are described and used to illustrate and discuss the possibility...... of manufacturing playing new strategic roles. Backward, forward and lateral interactive support are suggested to explicate how manufacturing can realize its new strategic roles. Finally, four new strategic roles of manufacturing are suggested. They are: innovation manufacturing, ramp-up manufacturing, primary...... manufacturing, and service manufacturing....

  12. Energetics Manufacturing Technology Center (EMTC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Manufacturing Technology Center (EMTC), established in 1994 by the Office of Naval Research (ONR) Manufacturing Technology (ManTech) Program, is Navy...

  13. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis

    DEFF Research Database (Denmark)

    Siontis, George C M; Praz, Fabien; Pilgrim, Thomas

    2016-01-01

    AIMS: In view of the currently available evidence from randomized trials, we aimed to compare the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the spectrum of risk and in important subgroups. METHODS AND RESULTS...

  14. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung-Han; Lefèvre, Thierry; Ahn, Jung-Ming

    2016-01-01

    BACKGROUND: Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices. OBJECTIVE...

  15. 40 CFR 60.483-1 - Alternative standards for valves-allowable percentage of valves leaking.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Alternative standards for valves-allowable percentage of valves leaking. 60.483-1 Section 60.483-1 Protection of Environment ENVIRONMENTAL... Before November 7, 2006 § 60.483-1 Alternative standards for valves—allowable percentage of...

  16. Single-centre experience with mitral valve repair in asymptomatic patients with severe mitral valve regurgitation

    NARCIS (Netherlands)

    W.J. van Leeuwen (Wouter); S.J. Head (Stuart); L.E. de Groot-de Laat (Lotte); M.L. Geleijnse (Marcel); A.J.J.C. Bogers (Ad); L.A. van Herwerden (Lex); A.P. Kappetein (Arie Pieter)

    2013-01-01

    textabstractOBJECTIVES: Guidelines recommend surgical mitral valve repair in selected patients with asymptomatic severe mitral valve regurgitation (MR), but the role of repair remains a matter of debate. Survival analyses of operated asymptomatic patients have been reported, but long-term haemodynam

  17. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  18. Replacing the valve restoring the flow: Effects of transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Wiegerinck, E.M.A.

    2016-01-01

    When conventional surgery is not an option due to high surgical risk, transcatheter aortic valve implantation (TAVI) is a firmly established alternative and an effective and safe treatment option in this patient population. This thesis focuses on treatment of aortic valve stenosis by TAVI. The aim i

  19. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  20. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops