WorldWideScience

Sample records for chamber system determinacao

  1. MPS II drift chamber system

    International Nuclear Information System (INIS)

    The MPS II detectors are narrow drift space chambers designed for high position resolution in a magnetic field and in a very high particle flux environment. Central to this implementation was the development of 3 multi-channel custom IC's and one multi-channel hybrid. The system is deadtimeless and requires no corrections on an anode-to-anode basis. Operational experience and relevance to ISABELLE detectors is discussed

  2. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  3. The CLAS drift chamber system

    CERN Document Server

    Mestayer, M D; Asavapibhop, B; Barbosa, F J; Bonneau, P; Christo, S B; Dodge, G E; Dooling, T; Duncan, W S; Dytman, S A; Feuerbach, R; Gilfoyle, G P; Gyurjyan, V; Hicks, K H; Hicks, R S; Hyde-Wright, C E; Jacobs, G; Klein, A; Klein, F J; Kossov, M; Kuhn, S E; Magahiz, R A; Major, R W; Martin, C; McGuckin, T; McNabb, J; Miskimen, R A; Müller, J A; Niczyporuk, B B; O'Meara, J E; Qin, L M; Raue, B A; Robb, J; Roudot, F; Schumacher, R A; Tedeschi, D J; Thompson, R A; Tilles, D; Tuzel, W; Vansyoc, K; Vineyard, M F; Weinstein, L B; Wilkin, G R; Yegneswaran, A; Yun, J

    2000-01-01

    Experimental Hall B at Jefferson Laboratory houses the CEBAF Large Acceptance Spectrometer, the magnetic field of which is produced by a superconducting toroid. The six coils of this toroid divide the detector azimuthally into six sectors, each of which contains three large multi-layer drift chambers for tracking charged particles produced from a fixed target on the toroidal axis. Within the 18 drift chambers are a total of 35,148 individually instrumented hexagonal drift cells. The novel geometry of these chambers provides for good tracking resolution and efficiency, along with large acceptance. The design and construction challenges posed by these large-scale detectors are described, and detailed results are presented from in-beam measurements.

  4. The CLAS drift chamber system

    Energy Technology Data Exchange (ETDEWEB)

    Mestayer, M.D.; Carman, D.S.; Asavaphibhop, B. [and others

    1999-04-01

    Experimental Hall B at Jefferson Laboratory houses the CEBAF Large Acceptance Spectrometer, the magnetic field of which is produced by a superconducting toroid. The six coils of this toroid divide the detector azimuthally into six sectors, each of which contains three large multi-layer drift chambers for tracking charged particles produced from a fixed target on a toroidal axis. Within the 18 drift chambers are a total of 35,148 individually instrumented hexagonal drift cells. The novel geometry of these chambers provides for good tracking resolution and efficiency, along with large acceptance. The design and construction challenges posed by these large-scale detectors are described, and detailed results are presented from in-beam measurements.

  5. The CLAS drift chamber system

    International Nuclear Information System (INIS)

    Experimental Hall B at Jefferson Laboratory houses the CEBAF Large Acceptance Spectrometer, the magnetic field of which is produced by a superconducting toroid. The six coils of this toroid divide the detector azimuthally into six sectors, each of which contains three large multi-layer drift chambers for tracking charged particles produced from a fixed target on the toroidal axis. Within the 18 drift chambers are a total of 35,148 individually instrumented hexagonal drift cells. The novel geometry of these chambers provides for good tracking resolution and efficiency, along with large acceptance. The design and construction challenges posed by these large-scale detectors are described, and detailed results are presented from in-beam measurements

  6. Ionization-chamber smoke detector system

    Science.gov (United States)

    Roe, Robert F.

    1976-10-19

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system is designed to reduce false alarms caused by fluctuations in ambient temperature. Means are provided for periodically firing the gas discharge triode and each time recording the triggering voltage required. A computer compares each triggering voltage with its predecessor. The computer is programmed to energize an alarm if the difference between the two compared voltages is a relatively large value indicative of particulates in the measuring chamber and to disregard smaller differences typically resulting from changes in ambient temperature.

  7. Actuator System with Dual Chambers

    DEFF Research Database (Denmark)

    2015-01-01

    (8), the lid having a shaft opening (17) for a shaft (6) coupled to the magnetic rotor (5), wherein the magnetic rotor (5), when inserted in the translator cylinder (2), is arranged to translate a linear movement of the translator cylinder (2) into a rotational movement of the magnetic rotor by using...... magnetic flux (82) interacting between the magnetic stator and the magnetic rotor, said rotational movements is being transferred through a shaft (6), the lid (8) with a shaft opening (17) arranged for receiving the shaft (6), wherein the shaft is arranged to make both the linear and the rotational...... movement in the shaft opening (17), the lid (8) being arranged for confining the second end (15) of the translator cylinder (2), the translator cylinder confined by the lid (8) forms,when divided by the magnetic rotor (5), a first chamber (TC) with a first volume and a second chamber(BC) with a second...

  8. The CDF vertex time projection chamber system

    International Nuclear Information System (INIS)

    The vertex time projection chamber (VTPC) system is one of the major components of the charged particle tracking system for the Collider Detector at Fermilab (CDF). The chambers cover about seven units of pseudorapidity (η) and must be capable of handling substantially more than the 30-35 charged particle tracks produced by typical anti pp collisions at center-of-mass energies of 1.8 TeV. The chambers are optimized to provide the good pattern recognition in the r-z view required to locate the event vertex, measure the overall event topology, and to complement the r-φ tracking in the large axial wire drift chamber that surrounds them. The chambers provide r-z information using TDC data from sense wire signals. Information on the φ of tracks is obtained from cathode pad signals on a subset of chambers read out by a FADC system. A similar system measures dE/dx of tracks in the forward cones surrounding the exiting beams. Because of the large number of photons that pass through the detector during each collision, novel techniques are required to reduce the amount of material in the chamber. These techniques include a custom surface mount integrated circuit preamplifier, epoxy-graphite and Kapton covered foam structural members, and miniature coaxial signal cables. The mechanical construction of the chamber, radiation length vs angle, and details of the electronics are described. The event reconstruction, corrections, and preliminary performance results for 1.8 TeV anti pp collisions are also discussed. (orig.)

  9. The LVD tracking system chambers

    International Nuclear Information System (INIS)

    The LVD detector can be defined as an underground observatory with the main objectives of studying neutrinos from stellar collapse and searching for point-like sources of gammas and neutrinos of very high energy. This multipurpose apparatus is being installed in hall A of the Gran Sasso Laboratory at a vertical depth of 3600 m.w.e. It consists of a large volume of liquid scintillator divided into modules and of a tracking system made of layers of streamer tubes. (orig./HSI)

  10. Opposite expansion system of fast bubble chambers

    International Nuclear Information System (INIS)

    Pneumatic opposite expansion system, operating on frequency up to 100 Hz and minimal cycle duration up to 3 ms, is created for accomplishingh expansion working cycle of a precision liquid-hydrogen fast bubble chamber. Fast-action hydraulic servo slide valves with electric control are used as command and control elements

  11. Brookhaven National Laboratory's multiparticle spectrometer drift chamber system

    International Nuclear Information System (INIS)

    A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties

  12. Data readout system for multiwire proportional chambers

    International Nuclear Information System (INIS)

    An electronic system for data readout from multiwire proportional chambers is described. The system will be used in a magnetic spectrometer for investigation into rare processes in an ITEP accelerating complex. Schematic solutions, used in the system allow one to maximally use the 'VECTOR' standard interface fast operation. The system assembly is completely made of domestic parts. The readout system structure developed allows one to easily reduce or increase the number of MPC channels questioned. The mean time, required for preparing data on cluster, does not exceed 1.5 μs

  13. Determination of the air attenuation and electronic loss for the free air concentric cylinders ionization chamber; Determinacao da atenuacao do ar e perda eletronica para a camara de ionizacao de ar livre de cilindros concentricos

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Hebert Pinto Silveira de

    2010-07-01

    Along the latest years, the LNMRI has been proceeding a continuous research work with a concentric cylinders type free air ionizing chamber (VICTOREEN, model 481), aiming to establish it as a new national standard, and, as a consequence, replace the worldwide accepted secondary standard, calibrated by PTB. Taking into account that the absolute determination of kerma in air with a free air ionizing chamber implies the acquirement of a number of correction factors. The main objective of the present work comprises the determination of the two factors, specifically, electronic loss (k{sub e}) and air attenuation (k{sub a}). The correction factors were obtained through mammography qualities reference spectrum, using Monte Carlo simulation method. The Penelope code was used in the simulation procedures. Simulations took place in two stages, the acquirement of specters related to the qualities of interest (mammography) with the x ray tube (Pantak, model HF160 e Panalytical, model XRF window), and the free-air ionization chamber. The data were compared to those related to the BIPM chamber, to electronic loss were not detected. The comparison between air attenuation factors was obtained data bellow 0.13%. (author)

  14. Procurement specification high vacuum test chamber and pumping system

    International Nuclear Information System (INIS)

    The specification establishes requirements for a high-vacuum test chamber, associated vacuum pumps, valves, controls, and instrumentation that shall be designed and fabricated for use as a test chamber for testing a closed loop Brayton Isotope Power System (BIPS) Ground Demonstration System (GDS). The vacuum system shall include all instrumentation required for pressure measurement and control of the vacuum pumping system. A general outline of the BIPS-GDS in the vacuum chamber and the preliminary piping and instrumentation interface to the vacuum chamber are shown

  15. Procurement specification high vacuum test chamber and pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Cormick, J. E.

    1976-05-31

    The specification establishes requirements for a high-vacuum test chamber, associated vacuum pumps, valves, controls, and instrumentation that shall be designed and fabricated for use as a test chamber for testing a closed loop Brayton Isotope Power System (BIPS) Ground Demonstration System (GDS). The vacuum system shall include all instrumentation required for pressure measurement and control of the vacuum pumping system. A general outline of the BIPS-GDS in the vacuum chamber and the preliminary piping and instrumentation interface to the vacuum chamber are shown.

  16. Data acquisition system for a deuteration chamber

    International Nuclear Information System (INIS)

    The work present is focusing auxiliary in the experiment the reaction of fusion in cold in the laboratory of Physical of Plasmas of Instituto Nacional de Investigaciones Nucleares. These systems of acquisition of data concrete to register in line surface of pressure and temperature in the gap of 5.6 x 10-4 to 1 x 103 and -270 to 1300 Centigrade degrees with help of personal computer. The manner of purchase in chamber of Deuterium is per middle of thermocouple with the object of whereas any control of the temperature in different point in the some of manner the signal of in for the system is the thermocouple (milli volts), the conversion analogy a digital is mean of Cad of 12 bits rate double slope the out is mean the PPI to send the signal to P C of these manner the read of the thermocouples is translate graphic or digital in the screen of the P C. In the phase of pressure element sensor is measure type Pirani, the measure is of manner of temperature. (Author)

  17. Vacuum Chamber for the Measurement System of the Beam Energy

    Science.gov (United States)

    Abakumova, E.; Achasov, M.; Dong, HaiYi; Qu, HuaMin; Krasnov, A.; Kosarev, A.; Muchnoi, N.; Pyata, E.; Xiao, Qiong; Mo, XiaoHu; Wang, YiFang; Zhukov, A.

    Vacuum chamber for the beam energy measurement system based on the Compton backscattering method is presented. The main elements of the chamber are GaAs entrance viewport and a copper mirror. The viewport design provides baking out of the vacuum chamber up to 250 °C. To produce the viewport, an original technology based on brazing GaAs plate by lead has been developed. The vacuum chambers were installed at the BEPC-II and VEPP-4 M colliders. After installation the residual gas pressure is about 10-10 Torr.

  18. Application of virtual instrument in radon chamber temperature monitor system

    International Nuclear Information System (INIS)

    Application of virtual instrument in radon chamber temperature monitor system is studied. Taking a kind of radon chamber temperature signal acquisition interface device based on micro-controller as example, application software is developed on virtual instrument platform LabVIEW. Full and accurate diagram block and virtual instrument panel are given. (authors)

  19. The electronics readout system for the OPAL Vertex Drift Chamber

    International Nuclear Information System (INIS)

    The Vertex Drift Chamber for the OPAL experiment at LEP provides high quality track co-ordinates using multi-hit sub-nanosecond timing to detect the drifted electrons. This paper explains the electronic techniques that have been devised and implemented for the detector. The overall performance of the system is demonstrated with measurements from the final OPAL chamber. (author)

  20. The pixel readout system for the PHENIX pad chambers

    International Nuclear Information System (INIS)

    A new concept for two-dimensional position readout of wire chambers is described. The basic idea is to use a cathode segmented into small pixels that are read out in specific groups (pads). The electronics is mounted on the outer face of the chamber with a chip-on-board technique, pushing the material thickness to a minimum. The system described here, containing 210 000 readout channels, will be used to read out the pad chambers in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)

  1. The pixel readout system for the PHENIX pad chambers

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Paul B., E-mail: paul.nilsson@kosufy.lu.se; Barrette, J.; Bryan, W.; Fraenkel, Z.; Greene, V.; Garpman, S.; Gustafsson, H.-A.; Jagadish, U.; Nikkinen, L.; Lacey, R.; Lauret, J.; Mark, S.K.; Milov, A.; O' Brien, E.; Oskarsson, A.; Oesterman, L.; Otterlund, I.; Pinkenburg, C.; Ravinovich, I.; Rose, A.; Silvermyr, D.; Sivertz, M.; Smith, M.; Stenlund, E.; Svensson, T.; Teodorescu, O.; Tserruya, I.; Xie, W.; Young, G.R

    1999-12-27

    A new concept for two-dimensional position readout of wire chambers is described. The basic idea is to use a cathode segmented into small pixels that are read out in specific groups (pads). The electronics is mounted on the outer face of the chamber with a chip-on-board technique, pushing the material thickness to a minimum. The system described here, containing 210 000 readout channels, will be used to read out the pad chambers in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)

  2. Development of standard ionization chamber counting system for activity measurements

    CERN Document Server

    Pyun, W B; Lee, H Y; Park, T S

    1998-01-01

    This study is to set up the activity measuring system using a 4 pi gamma ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4 pi gamma ionization chamber is about 0.02% and the background current is 0.054+-0.024 pA. this 4 pi gamma ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4 pi gamma ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement.

  3. Laser calibration system for the CERES Time Projection Chamber

    OpenAIRE

    Miskowiec, Dariusz; Braun-Munzinger, Peter

    2008-01-01

    A Nd:YAG laser was used to simulate charged particle tracks at known positions in the CERES Time Projection Chamber at the CERN SPS. The system was primarily developed to study the response of the readout electronics and to calibrate the electron drift velocity. Further applications were the determination of the gating grid transparency, the chamber position calibration, and long-term monitoring of drift properties of the gas in the detector.

  4. Inertial confinement fusion reaction chamber and power conversion system study

    International Nuclear Information System (INIS)

    GA Technologies has developed a conceptual ICF reactor system based on the Cascade rotating-bed reaction chamber concept. Unique features of the system design include the use of low activation SiC in a reaction chamber constructed of box-shaped tiles held together in compression by prestressing tendons to the vacuum chamber. Circulating Li2O granules serve as the tritium breeding and energy transport material, cascading down the sides of the reaction chamber to the power conversion system. The total tritium inventory of the system is 6 kg; tritium recovery is accomplished directly from the granules via the vacuum system. A system for centrifugal throw transport of the hot Li2O granules from the reaction chamber to the power conversion system has been developed. A number of issues were evaluated during the course of this study. These include the response of first-layer granules to the intense microexplosion surface heat flux, cost effective fabrication of Li2O granules, tritium inventory and recovery issues, the thermodynamics of solids-flow options, vacuum versus helium-medium heat transfer, and the tradeoffs of capital cost versus efficiency for alternate heat exchange and power conversion system option. The resultant design options appear to be economically competitive, safe, and environmentally attractive

  5. Drift chamber readout system of the DIRAC experiment

    CERN Document Server

    Afanasiev, L G

    2002-01-01

    A drift chamber readout system of the DIRAC experiment at CERN is presented. The system is intended to read out the signals from planar chambers operating in a high current mode. The sense wire signals are digitized in the 16-channel time-to-digital converter boards which are plugged in the signal plane connectors. This design results in a reduced number of modules, a small number of cables and high noise immunity. The system has been successfully operating in the experiment since 1999.

  6. The Cathode Strip Chamber Data Acquisition System for CMS

    CERN Document Server

    Bylsma, B G; Gilmore, J R; Gu, J H; Ling, T Y

    2007-01-01

    The Cathode Strip Chamber (CSC) [1] Data Acquisition (DAQ) system for the CMS [2] experiment at the LHC [3] will be described. The CSC system is large, consisting of 218K cathode channels and 183K anode channels. This leads to a substantial data rate of ~1.5GByte/s at LHC design luminosity (1034cm-2s-1) and the CMS first level trigger (L1A) rate of 100KHz. The DAQ system consists of three parts. The first part is on-chamber Cathode Front End Boards (CFEB)[4], which amplify, shape, store, and digitise chamber cathode signals, and Anode Front End Boards (AFEB)[5], which amplify, shape and discriminate chamber anode signals. The second part is the Peripheral Crate Data Acquisition Motherboards (DAQMB), which control the onchamber electronics and the readout of the chamber. The third part is the off-detector DAQ interface boards, which perform real time error checking, electronics reset requests and data concentration. It passes the resulting data to a CSC local DAQ farm, as well as CMS main DAQ [6]. All electron...

  7. Development of underwater surface inspection system for BWR suppression chamber

    International Nuclear Information System (INIS)

    In order to inspect underwater paints surface of BWR suppression chamber as an in-service inspection, the underwater surface inspection system has been developed, which consists of magnetic crawler, crud recovery nozzles and special camera unit. The system can move on wall surface of pressure suppression chamber with magnetic crawler to inspect surface paints films under the muddy water with special camera unit after removing surface cruds. Based on inspection results, the paint films inspection criteria to assess degradation of paints films were proposed. (T. Tanaka)

  8. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18F and 153Sm were obtained, making possible to determine activities of these radionuclides. (author)

  9. Safety-Enclosure System For MOCVD Process Chamber

    Science.gov (United States)

    Singletery, James, Jr.; Velasquez, Hugo; Warner, Joseph

    1995-01-01

    Safety-enclosure system filled with nitrogen surrounds reaction chamber in which metallo-organic chemical vapor deposition (MOCVD) performed. Designed to protect against explosions and/or escaping toxic gases and particulates. Gas-purification subsystem ensures during loading and unloading of process materials, interior of MOCVD chamber exposed to less than 1 ppm of oxygen and less than 5 ppm of water in nitrogen atmosphere. Toxic byproducts of MOCVD process collected within inert atmosphere. Enclosure strong enough to contain any fragments in unlikely event of explosion.

  10. Magma chamber processes in central volcanic systems of Iceland

    DEFF Research Database (Denmark)

    Þórarinsson, Sigurjón Böðvar; Tegner, Christian

    2009-01-01

    olivine basalts from Iceland that had undergone about 20% crystallisation of olivine, plagioclase and clinopyroxene and that the macrorhythmic units formed from thin magma layers not exceeding 200-300 m. Such a "mushy" magma chamber is akin to volcanic plumbing systems in settings of high magma supply...

  11. Gated grid system used with a time projection chamber

    International Nuclear Information System (INIS)

    A gated grid system has been developed for the TRIUMF time projection chamber to suppress drift field distortions caused by positive ions produced at the endcap proportional wires. Good spatial resolution in the TPC has been thereby maintained over a large range of counting rates. (orig.)

  12. A software system for measuring bubble chamber films on line

    International Nuclear Information System (INIS)

    A system has been developed for measuring bubble chamber films on line. This report describes the computer program used in the on-line system. The program guides the operator during the measurements, makes on-line control of the measurement data and produces output data on magnetic tape in a format suitable as input for the geometry programme THRESH. The on-line program is coded in the assembly language OSAS-A used for CDC 8090 computers. (Auth.)

  13. Permeability evaluation of reservoir rocks modeled in multi scale percolation systems; Determinacao da permeabilidade de rochas reservatorio reconstruidas em sistemas de percolacao multiescala

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Celso P.; Philippi, Paulo C.; Damiani, Marcos C.; Cunha Neto, Jose A.B. da [Santa Catarina Univ., Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica. Lab. de Meios Porosos e Propriedades Termofisicas]. E-mail: celso@lmpt.ufsc.br; philippi@lmpt.ufsc.br; damiani@lmpt.ufsc.br; bellini@lmpt.ufsc.br; Daian, Jean-Francois (Laboratoire d' Etudes des Transferts en Hydrologie et Environement)

    2000-07-01

    Multiscale percolation systems (MPS) are presented as giving a fast method for calculating intrinsic permeability of porous media. MPS were proposed to study invasion processes in porous media considering the porous section as a polydisperse structure, which modify its geometrical structure when the scale of observation is changed. Multiscale models are non-regular percolation systems and do not have the following limitations common to classical percolation systems: it is not necessary to choose a particular value for the coordination number; constrictions appears naturally as pores of smaller diameters connecting pores of greater diameters, as the result of superposing different scales (Fernandes, C. P., Magnani, F.S., Philippi, P.C., Daian, J.F. 1996, Multiscale reconstruction of the porous structure, Physical Review E, 54, 1734-1742). Present paper describes the numerical prediction of intrinsic permeability of petroleum reservoir rocks by using a MPS approach. Rock's microstructure is reconstructed in a three dimensional MPS, starting from 2D thin sections geometrical information, after binarization and microstructural analysis. Intrinsic permeability is, then, calculated, using a procedure based on renormalization theory. The method is presented and applied for the calculation of intrinsic permeability of several petroleum reservoir rocks. Results are compared with experimental data. (author)

  14. Distributed remote temperature monitoring system for INDUS-2 vacuum chambers

    International Nuclear Information System (INIS)

    Indus-2, a 2.5 GeV Synchrotron Radiation Source (SRS) at Indore has a large vacuum system. The vacuum envelope of Indus-2 ring comprises of 16 dipole chambers as vital parts. Each chamber has 4 photon absorbers and three beam line ports blanked with end flanges. Temperature monitoring of critical vacuum components during operation of Indus-2 ring is an important requirement. The paper discusses a distributed, 160 channel remote temperature monitoring system developed and deployed for this purpose using microcontroller based, modular Temperature Monitoring Units (TMU). The cabling has been extensively minimized using RS485 system and keeping trip relay contacts of all units in series. For ensuring proper signal conditioning of thermocouple outputs (K-type) and successful operation over RS485 bus, many precautions were taken considering the close proximity to the storage ring. We also discuss the software for vacuum chamber temperature monitoring and safety system. The software developed using LabVIEW, has important features like modularity, client-server architecture, local and global database logging, alarms and trips, event and error logging, provision of various important configurations, communications handling etc. (author)

  15. Method for study of a drift chamber detector system

    International Nuclear Information System (INIS)

    To define an algorithm for calculation of a linear trajectory parameters, the physical and geometrical characteristics of the drift chamber detector located in the volume, and these of the measurement and storing system have been studied, the left-right ambiguit problem has been specially investigated. The algorithm (square roots method and iteration) has been tested with Monte-Carlo calculation, before it has been applied to physical events

  16. Industrial defectoscope based on multiwire proportional chamber in CAMAC system

    International Nuclear Information System (INIS)

    The defectoscope for non-destructive testing has been built at the Institute of Radioelectronics in collaboration with the Electrotechnical Institute, Non-destructive Division. The defectoscope consists of the following parts: gamma radiation detector, multiwire proportional chamber with γ-e converter, preamplifier system attached directly to the chamber wires, logic module of CAMAC philoscopy, and MERA 300 minicomputer. The defectoscope is used to detect material flaws in tested objects, irradiated from an internal radiation source. Minicomputer used enables data processing. The data collected in mincomputer memory are the radiological image of a tested object. It is possible to display the collected image on a television monitor, to display any profile of the image on an oscilloscope, to print the map of the image on a mosaic printer. (author)

  17. Repetition target and fusion chamber systems for HiPER

    International Nuclear Information System (INIS)

    We review development in the repetition-rate target area systems and technologies within the Work Package 15 of the HiPER Preparatory Phase project. The activities carried out in 2009-2010 have been involving analysis of solutions and baseline design of major elements of the repetition-rated fusion chamber, analysis of prospective injector technologies, numerical modelling of target survival during acceleration phase and during flight in the environment of fusion chamber, analysis of options of remote handling, systems of mitigation of fusion debris, and others. The suggested solutions assume operation at the repetition rate of 10 Hz and fusion yield between 20 and 100 MJ. Shock ignition is assumed as the baseline ignition scenario, although some technologies are applicable in the fast ignition; a number of the technologies identified are exploitable as well in the indirect drive. The operation of the HiPER repetition-rate chamber will contribute to technology development for the Demonstration Reactor HiPER facility. (authors)

  18. Design of the OMEGA Laser Target Chamber Tritium Removal System

    International Nuclear Information System (INIS)

    Preparations are currently underway at the OMEGA laser at the University of Rochester Laboratory for Laser Energetics (UR/LLE) to conduct direct drive laser implosion campaigns with inertial confinement fusion targets containing deuterium-tritium (DT) cryogenic ice layers. The OMEGA Cryogenic Target Handling System will fill plastic targets with high-pressure DT (150 MPa) at 300 to 500 K, cool them down to cryogenic temperature (<25 K), form the DT ice layer, and transport the targets to the OMEGA laser target chamber. Targets will then be shot with the 60-beam 30-kJ OMEGA laser. A tritium removal system has been designed to remove tritium from effluents associated with operation of the target chamber and its associated diagnostic antechambers, vacuum pumping systems, and target insertion systems. The design of the target chamber tritium removal system (TCTRS) is based on catalytic oxidation of DT and tritiated methane to tritiated water (DTO), followed by immobilization of DTO on molecular sieves. The design of the TCTRS presented a challenge due to the low tritium release limits dictated by the tritium license at UR/LLE. Aspen Plus, a commercial software package intended for the simulation and design of chemical processing systems operating at steady state, was used to simulate and design the TCTRS. A second commercial software package, Aspen ADSIM, was used to simulate and design the TCTRS molecular sieve beds, which operate at unsteady state. In this paper, we describe the design of the TCTRS and the benefits that were realized by use of the Aspen Plus and Aspen ADSIM software packages

  19. Multi axis motor control system for BARC-TIFR LINAC scattering chamber

    International Nuclear Information System (INIS)

    A general purpose scattering chamber of 150 cm diameter and 50 cm height is recently installed at BARC-TIFR LINAC facility. Scattering chamber is used in several experiments using particle accelerators. A remote controlled system is developed to perform various operation in scattering chamber. Four servo motors with PLC interface have been used to meet the precise positioning of target and detectors in scattering chamber. User interface software has been developed in Java which interacts with the system over Ethernet

  20. 3D spectral imaging system for anterior chamber metrology

    Science.gov (United States)

    Anderson, Trevor; Segref, Armin; Frisken, Grant; Frisken, Steven

    2015-03-01

    Accurate metrology of the anterior chamber of the eye is useful for a number of diagnostic and clinical applications. In particular, accurate corneal topography and corneal thickness data is desirable for fitting contact lenses, screening for diseases and monitoring corneal changes. Anterior OCT systems can be used to measure anterior chamber surfaces, however accurate curvature measurements for single point scanning systems are known to be very sensitive to patient movement. To overcome this problem we have developed a parallel 3D spectral metrology system that captures simultaneous A-scans on a 2D lateral grid. This approach enables estimates of the elevation and curvature of anterior and posterior corneal surfaces that are robust to sample movement. Furthermore, multiple simultaneous surface measurements greatly improve the ability to register consecutive frames and enable aggregate measurements over a finer lateral grid. A key element of our approach has been to exploit standard low cost optical components including lenslet arrays and a 2D sensor to provide a path towards low cost implementation. We demonstrate first prototypes based on 6 Mpixel sensor using a 250 μm pitch lenslet array with 300 sample beams to achieve an RMS elevation accuracy of 1μm with 95 dB sensitivity and a 7.0 mm range. Initial tests on Porcine eyes, model eyes and calibration spheres demonstrate the validity of the concept. With the next iteration of designs we expect to be able to achieve over 1000 simultaneous A-scans in excess of 75 frames per second.

  1. Reactivity Worth of the Flooding of the ETRR-2 Second Shutdown System Chambers

    International Nuclear Information System (INIS)

    The ETRR-2 research reactor has a second shutdown system consisting of four chambers surrounding the core chimney.These chambers are to be filled with Gadolinium solution in case of failure of the first shutdown system within a certain time period. The reactor core chimney together with second shutdown system four chambers lie inside the reactor main water pool.The possibility of the chambers to be flooded with water is considered to be one of the safety issues to be addressed. As the reactor core is very heterogeneous, the reactivity effects of each individual chamber are different. Also, the reactivity worth of these chambers depends on the core configuration.The present study aims to evaluate the reactivity worth of each individual chamber, the total worth of all the chambers and the maximum worth of any flooded chamber in case of the other chambers being filled with nitrogen. Certain conclusions are drawn regarding the safety of the ET-RR-2 reactor in case of the chambers being filled with water and the second shutdown system being on demand

  2. A new occlusive patch test system comparable to IQ and Finn chambers

    Directory of Open Access Journals (Sweden)

    Shaziya Z Sajun Merchant

    2014-01-01

    Full Text Available Background: A good patch test system should have good adhesion and contact, and minimal leakage; Finn and IQ patch test system have these properties but are expensive. Aims: To develop a new cost-effective occlusive patch test system that had good contact with the skin and was non-irritant. Methods: The system (designated Chamber X was fabricated using a semi-permeable tape and a flexible virgin plastic chamber. Chamber X was developed by (i selecting adhesive tape based on its non irritancy and adhesive potential (ii testing plastic chamber material for its skin irritancy (iii testing the assembled system against Finn, IQ and locally available chambers for irritancy, contact, leakage and occlusivity. Results: Chamber X showed better occlusion than IQ, Finn and locally available chambers and was comparable to, (P > 0.05 IQ and Finn in terms of irritancy, contact and leakage. Conclusions: The results demonstrate that the Chamber X offers a cost effective patch test system comparable to IQ and Finn chambers in terms of safety, adhesion, leakage and occlusivity.

  3. Assembly chamber vacuum ITER: Development robotic welding system

    International Nuclear Information System (INIS)

    The aim of ITER is to demonstrate the scientific and technical feasibility of nuclear fusion to generate energy through the construction of a pilot plant fusion power. It is an international project with the participation of different countries. The main element is the ITER machine is located within a cylindrical stainless steel element called cryostat about 30 meters in height and diameter. The machine is composed of different subsystems among which is the vacuum chamber and ports. This chamber is a stainless steel double wall with toroidal shape, composed of 9 sections to be joined in situ to constitute it. There are also 53 structures ports that go together to the chamber and should also be assembled in situ. (Author)

  4. Heat exchanger. [rocket combustion chambers and cooling systems

    Science.gov (United States)

    Sokolowski, D. E. (Inventor)

    1978-01-01

    A heat exchanger, as exemplified by a rocket combustion chamber, is constructed by stacking thin metal rings having microsized openings therein at selective locations to form cooling passages defined by an inner wall, an outer wall and fins. Suitable manifolds are provided at each end of the rocket chamber. In addition to the cooling channel openings, coolant feed openings may be formed in each of rings. The coolant feed openings may be nested or positioned within generally U-shaped cooling channel openings. Compression on the stacked rings may be maintained by welds or the like or by bolts extending through the stacked rings.

  5. Wire spark chamber capacitive readout system with low leakage current and small systematic error

    Energy Technology Data Exchange (ETDEWEB)

    Anderhub, H.B.; Boecklin, J.; von Gunten, H.P.; Koenig, H.; Le Coultre, P.; Makowiecki, D.; Seiler, P.G. (Eidgenoessische Technische Hochschule, Zurich (Switzerland). Lab. fuer Hochenergiephysik)

    1983-02-15

    A wire spark chamber capacitive readout system with analog FET switch multiplexing and CAMAC interface is described. Two wire planes per chamber are read out. The information of each plane is sequentially digitized in one ADC. This and the low leakage current of the FET switches guarantee a small systematic error of the measurement of the spark position.

  6. A wire spark chamber capacitive readout system woth low leakage current and small systematic error

    International Nuclear Information System (INIS)

    A wire spark chamber capacitive readout system with analog FET switch multiplexing and CAMAC interface is described. Two wire planes per chamber are read out. The information of each plane is sequentially digitized in one ADC. This and the low leakage current of the FET switches guarantee a small systematic error of the measurement of the spark position. (orig.)

  7. A new occlusive patch test system comparable to IQ and Finn chambers

    OpenAIRE

    Shaziya Z Sajun Merchant; Ashlesha D Vaidya; Anjali Salvi; Rajiv S Joshi; Rashmikant B Mohile

    2014-01-01

    Background: A good patch test system should have good adhesion and contact, and minimal leakage; Finn and IQ patch test system have these properties but are expensive. Aims: To develop a new cost-effective occlusive patch test system that had good contact with the skin and was non-irritant. Methods: The system (designated Chamber X) was fabricated using a semi-permeable tape and a flexible virgin plastic chamber. Chamber X was developed by (i) selecting adhesive tape based on its non irritanc...

  8. Data analysis for bubble chamber and hybrid systems

    International Nuclear Information System (INIS)

    The course will be mainly devoted to data-processing aspects of present-day bubble chamber experiments involving the use of external particle detectors. Present trends will be briefly reviewed from the point of view of instrumentation and trigger conditions employed to realize the physics objectives. The lectures will include a discussion of software aids and disciplines for program maintenance and development and the management of data structures. (orig.)

  9. Design and technology of production of multichannel system of drift chambers

    International Nuclear Information System (INIS)

    Design and assembly procedure are described of a drift chamber system for pion and kaon formfactor determination experiments in π-e and K-e scattering. The chambers were made of an epoxy resin by the high-pressure die casting method. In the glass-reinforced frames there are four holes with the hole axis spacings maintained within an accuracy of +-2 μm. These distances are system basic dimensions and all of the manufacturing operations are carried out relative to them. The blocks include 8 chambers and represent a unified gas volume for all the chambers. The manufacturing procedure proposed may be used to make chambers up to 100x100 cm2 in size

  10. Wire chamber requirements and tracking simulation studies for tracking systems at the superconducting super collider

    International Nuclear Information System (INIS)

    Limitations placed on wire chambers by radiation damage and rate requirements in the SSC environment are reviewed. Possible conceptual designs for wire chamber tracking systems which meet these requirements are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum-bias background events, are examined. Results of some preliminary pattern recognition studies are given. Such computer simulation studies are necessary to determine the feasibility of wire chamber tracking systems for complex events in a high-rate environment such as the SSC. (orig.)

  11. Extraction characteristics of a low-energy ion beam system with a remote plasma chamber

    International Nuclear Information System (INIS)

    Low-energy argon beams were extracted from a dual-chamber ion source system. The first chamber is a quartz cylinder where dense inductively coupled plasmas were produced using 13.56 MHz radio frequency (rf) power. The discharge was driven into an adjacent chamber which acts as a reservoir for ion beam extraction using a dual-electrode extractor configuration. Extraction of ions from the second chamber with energies in the 100 eV range was achieved while minimizing fluctuations induced by the rf signal. A custom-built retarding potential analyzer was used to analyze the effectiveness of ion beam transport using the remote plasma chamber. Well-defined beams were extracted between 60 and 100 V extraction potentials at 50–100 W rf powers. An increase in rf power resulted in an increase in average ion energy, increase in ion current density while the energy spread remains constant

  12. Extraction characteristics of a low-energy ion beam system with a remote plasma chamber

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M. R., E-mail: mrvasquez@coe.upd.edu.ph [Department of Mining, Metallurgical, and Materials Engineering, College of Engineering, University of the Philippines, Diliman, Quezon City 1101 (Philippines); Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2016-02-15

    Low-energy argon beams were extracted from a dual-chamber ion source system. The first chamber is a quartz cylinder where dense inductively coupled plasmas were produced using 13.56 MHz radio frequency (rf) power. The discharge was driven into an adjacent chamber which acts as a reservoir for ion beam extraction using a dual-electrode extractor configuration. Extraction of ions from the second chamber with energies in the 100 eV range was achieved while minimizing fluctuations induced by the rf signal. A custom-built retarding potential analyzer was used to analyze the effectiveness of ion beam transport using the remote plasma chamber. Well-defined beams were extracted between 60 and 100 V extraction potentials at 50–100 W rf powers. An increase in rf power resulted in an increase in average ion energy, increase in ion current density while the energy spread remains constant.

  13. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are increa

  14. Studying energy evolution in the discharge chamber of a multichamber lightning protection system

    Science.gov (United States)

    Pinchuk, M. E.; Budin, A. V.; Kumkova, I. I.; Chusov, A. N.

    2016-04-01

    We present experimental data on the distribution of energy deposition along the discharge chamber of a multichamber lightning protection system at the initial stage of a discharge process modeling a lightning current pulse with 10 kA amplitude. The multichamber system comprised serially connected gas-discharge chambers. The breakdown between electrodes situated on the bottom of a channel in each chamber induces the formation of a shock wave. Subsequent energy evolution during the development of discharge proceeds in the entire volume bounded by the shock wave.

  15. Design and construction of an interface system for the extrapolation chamber from the beta secondary standard

    International Nuclear Information System (INIS)

    The Interface System for the Extrapolation Chamber (SICE) contains several devices handled by a personal computer (PC), it is able to get the required data to calculate the absorbed dose due to Beta radiation. The main functions of the system are: a) Measures the ionization current or charge stored in the extrapolation chamber. b) Adjusts the distance between the plates of the extrapolation chamber automatically. c) Adjust the bias voltage of the extrapolation chamber automatically. d) Acquires the data of the temperature, atmospheric pressure, relative humidity of the environment and the voltage applied between the plates of the extrapolation chamber. e) Calculates the effective area of the plates of the extrapolation chamber and the real distance between them. f) Stores all the obtained information in hard disk or diskette. A comparison between the desired distance and the distance in the dial of the extrapolation chamber, show us that the resolution of the system is of 20 μm. The voltage can be changed between -399.9 V and +399.9 V with an error of less the 3 % with a resolution of 0.1 V. These uncertainties are between the accepted limits to be used in the determination of the absolute absorbed dose due to beta radiation. (Author)

  16. Measurement system for evaluation of the muon chambers for the LHCb experiment

    International Nuclear Information System (INIS)

    In a detector with the complexity of the LHCb, where only for the muon system more than 1300 chambers, divided into 20 different types, will be used, resulting on more than 120 k channels to be readout, it is of crucial importance to study the many types of chambers to create a complete knowledge of the detector operation and to guarantee a high-quality performance during the experiment. To make it possible, a complete setup was built and a C++ based software was developed to carry out a set of measurements on the full-equipped chambers of the LHCb muon detector. The setup is made of front-end control electronics, high-voltage supply and acquisition circuitry while the software, running on a PC, remotely controls each element of the system and implements a number of automatized procedures to assess the main characteristics of the chambers. The main advantages of this system are its versatility and speed of measurement which are crucial to the experiment since there is the need to characterize every single chamber before final installation. Moreover, in this work it was proposed to measure the starting knee of the high-voltage operational plateau without the use of an external trigger by making use of the internal structure of the chambers. Two laboratories were prepared at CERN (European Laboratory for Particle Physics) to receive this system; one used to test chambers arrived from the CERN itself and the PNPI (Petersburg Nuclear Physics Institute) production sites, and one to test the chambers arrived from the INFN (National Institute of Nuclear Physics) production sites. In this document, the hardware and software setup will be presented together with the measurement-oriented implementations.

  17. Construction of an alternative system for the determination of sensitiveness of neutron radioisotopic primary source standardization system; Construcao de um sistema alternativo para a determinacao da sensibilidade do sistema padronizacao primaria de fontes radioisotopicas de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Sandro Passos; Silva, Ademir Xavier da [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Energia Nuclear; Pereira, Walsan Wagner; Fonseca, Evaldo S. da; Patrao, Karla C. de Souza [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI); Castro, Leonardo Curvello de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Programa de Pos-Graduacao; Bittencourt, Guilherme Rodrigues [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). PIBIC

    2009-07-01

    This work studied, through the Monte Carlo modelling, a irradiation system for the aqueous solution MnSO{sub 4} to be used in the proceeding of determination of counting efficiency of the manganese sulfate bath

  18. Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  19. Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M Jr; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 microns and 30-200 microradians. Systematic errors on displacements are estimated to be 340-590 microns based on comparisons with independent photogrammetry measurements.

  20. A Tale of Two Chambers: Iterative Approaches and Lessons Learned from Life Support Systems Testing in Altitude Chambers

    Science.gov (United States)

    Callini, Gianluca

    2016-01-01

    The drive for the journey to Mars is in a higher gear than ever before. We are developing new spacecraft and life support systems to take humans to the Red Planet. The journey that development hardware takes before its final incarnation in a fully integrated spacecraft can take years, as is the case for the Orion environmental control and life support system (ECLSS). Through the Pressure Integrated Suit Test (PIST) series, NASA personnel at Johnson Space Center have been characterizing the behavior of a closed loop ECLSS in the event of cabin depressurization. This kind of testing - one of the most hazardous activities performed at JSC - requires an iterative approach, increasing in complexity and hazards). The PIST series, conducted in the Crew and Thermal Systems Division (CTSD) 11-ft Chamber, started with unmanned test precursors before moving to a human-in-the-loop phase, and continues to evolve with the eventual goal of a qualification test for the final system that will be installed on Orion. Meanwhile, the Human Exploration Spacecraft Testbed for Integration and Advancement (HESTIA) program is an effort to research and develop technologies that will work in concert to support habitation on Mars. September 2015 marked the first unmanned HESTIA test, with the goal of characterizing how ECLSS technologies work together in a closed environment. HESTIA will culminate in crewed testing, but it can benefit from the lessons learned from another test that is farther ahead in its development and life cycle. Discussing PIST and HESTIA, this paper illustrates how we approach testing, the kind of information that facility teams need to ensure efficient collaborations and successful testing, and how we can apply what we learn to execute future tests.

  1. Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams

    International Nuclear Information System (INIS)

    Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this PhD program. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system. (author)

  2. Gamma compensated pulsed ionization chamber wide range neutron/reactor power measurement system

    International Nuclear Information System (INIS)

    An improved method and system of pulsed mode operation of ionization chambers is described in which a single sensor system with gamma compensation is provided by sampling, squaring, automatic gate selector, and differential amplifier circuit means, employed in relation to chambers sensitized to neutron plus gamma and gamma only to subtract out the gamma component, wherein squaring functions circuits, a supplemental high performance pulse rate system, and operational and display mode selection and sampling gate circuits are utilized to provide automatic wide range linear measurement capability for neutron flux and reactor power. Neon is employed as an additive in the ionization chambers to provide independence of ionized gas kinetics temperature effects, and the pulsed mode of operation provide independence of high temperature insulator leakage effects. (auth)

  3. Calculational-theoretical studies of the system of local automated regulators and lateral ionization chambers

    International Nuclear Information System (INIS)

    Methods of engineering synthesis of the systems for nuclear reactor local automated power regulation and radial-azimuthal energy distribution stabilization operating according to lateral ionization chamber signals are described. Results of calculational-theoretical investigations into the system efficiency and peculiarities of its reaction to some perturbations typical of the RBMK type reactors are considered

  4. The automatic test system for the L3 muon drift chamber amplifiers

    International Nuclear Information System (INIS)

    We describe the system we developed to test the linearity of wire chambers amplifiers of the muon spectrometer presently in construction for the L3 experiment at LEP. The system, controlled by an Apple II computer, is capable of localizing both defective components and faults in the printed board. It will be used to perform the large scale quality control of the amplifier cards

  5. The Systems of the Proportional Chambers Registration Electronics for Present Experiments in Nuclear Physics

    International Nuclear Information System (INIS)

    The main direction of the development of present systems of the proportional chambers registration electronics for experiments in nuclear physics is described. The following features of each type of systems and their future are considered in the review. (author). 23 refs., 11 figs

  6. Architecture of the SOFIT autonomous system for processing images from track chambers

    International Nuclear Information System (INIS)

    The problems of designing automated systems for measurements and analysis of photo images of particle tracks detected in bubble and spark chambers. The SOFIT system used for processing data from the track chambers is described. The system is based on the PUOS-type scanning measuring projector and EhLEKTRONIKA-60 microcomouter. Incorporation of the microcomputer directly in the electronic equipment of the measuring system permits to consecutively improve the system technical characteristics by means of stage-by-stage automation of processes controlling measuring carriages, tape-drive and illuminators. Electronic units of the system are performed on the K155 series microcirccuits. The system programming and performance capabilities enable to construct autonomous systems based on recent scanning measuring tables with diffraction gratings

  7. An on-line system for the analysis of track chamber film

    International Nuclear Information System (INIS)

    The Inter-University Institute for High Energies in Brussels is involved in experiments based on the analysis of film from several track chambers: the 'big' and 'little' European Bubble Chambers (BEBC and LEBC) and the UA5 streamer chamber. In order to scan and measure these difficult pictures in optimal conditions, a rather versatile device which we originally called 'BEBC table' was designed in the laboratory, offering a high-precision track-ball driven X-Y stage, optical projection with dual magnification, and various operator controls. A PDP-11/40 running RSX-11 M provides real-time support for five of these devices. A link between the PDP-11 and a DEC system 10 allows the geometrical reconstruction of the events to be performed on-line, with feedback to the BEBC table operator. (orig.)

  8. Real-time dielectric-film thickness measurement system for plasma processing chamber wall monitoring.

    Science.gov (United States)

    Kim, Jin-Yong; Chung, Chin-Wook

    2015-12-01

    An in-situ real-time processing chamber wall monitoring system was developed. In order to measure the thickness of the dielectric film, two frequencies of small sinusoidal voltage (∼1 V) signals were applied to an electrically floated planar type probe, which is positioned at chamber wall surface, and the amplitudes of the currents and the phase differences between the voltage and current were measured. By using an equivalent sheath circuit model including a sheath capacitance, the dielectric thickness can be obtained. Experiments were performed in various plasma condition, and reliable dielectric film thickness was obtained regardless of the plasma properties. In addition, availability in commercial chamber for plasma enhanced chemical vapor deposition was verified. This study is expected to contribute to the control of etching and deposition processes and optimization of periodic maintenance in semiconductor manufacturing process. PMID:26724022

  9. Real-time dielectric-film thickness measurement system for plasma processing chamber wall monitoring

    Science.gov (United States)

    Kim, Jin-Yong; Chung, Chin-Wook

    2015-12-01

    An in-situ real-time processing chamber wall monitoring system was developed. In order to measure the thickness of the dielectric film, two frequencies of small sinusoidal voltage (˜1 V) signals were applied to an electrically floated planar type probe, which is positioned at chamber wall surface, and the amplitudes of the currents and the phase differences between the voltage and current were measured. By using an equivalent sheath circuit model including a sheath capacitance, the dielectric thickness can be obtained. Experiments were performed in various plasma condition, and reliable dielectric film thickness was obtained regardless of the plasma properties. In addition, availability in commercial chamber for plasma enhanced chemical vapor deposition was verified. This study is expected to contribute to the control of etching and deposition processes and optimization of periodic maintenance in semiconductor manufacturing process.

  10. Power supply monitoring system for high-voltage supply to an ionisation chamber

    International Nuclear Information System (INIS)

    The ionization chamber is used for control of particle accelerators and consequently loaded with high dose-rates during radiation pulses. The measuring equipment consists of a transmitter- and receiver-system with opto-coupler, hallgenerators, field plates or isolating transformer and controls a relais which allows to block the direct current components. (DG)

  11. Carbonylative Heck Reactions Using CO Generated ex Situ in a Two-Chamber System

    DEFF Research Database (Denmark)

    Hermange, Philippe; Gøgsig, Thomas; Lindhardt, Anders Thyboe; Taaning, Rolf Hejle; Skrydstrup, Troels

    2011-01-01

    A carbonylative Heck reaction of aryl iodides and styrene derivatives employing a two-chamber system using a stable, crystalline, and nontransition metal based carbon monoxide source is reported. By applying near-stoichiometric amounts of the carbon monoxide precursor, an effective exploitation of...

  12. Evaluation of a transfer system for calibration of kVp meters and ionization chambers

    International Nuclear Information System (INIS)

    The assessment and control of the performance characteristics of X-ray generators and tubes is an essential part of a quality assurance programme, because the use of the X-rays in medicine for diagnosis of injuries and diseases represents the largest man-made source of public exposure to ionizing radiation. Others authors have suggested methods to determine the correct X-ray tube voltage to complete the characterization of standard radiation qualities. A method by spectrometry to calibrate ionization chambers and kVp meters used for quality control tests in diagnostic radiology has been applied at the Calibration Laboratory at IPEN. A transfer system for diagnostic radiology calibration was developed at IPEN as an alternative to calibrate those instruments that measure kVp and air kerma values. It consists of a pair of identical ionization chambers in form, but differing only by the electrode material: one is made of aluminum, and the other is made of graphite. It was calibrated using a spectrometer and a standard ionization chamber traceable to the German Primary Laboratory (Physikalisch-Technische Bundesanstalt - PTB). In this study the behaviour of the transfer system was analysed in the standard beams of two X-ray equipment of the Calibration Laboratory. The low energy X-ray generating system consists of a Rigaku Denki generator, model Geigerflex, coupled to a Philips tube model PW/2184/00 (Tungsten target and Beryllium window). Measurements were taken from 30 to 50 kV. The diagnostic radiology X-ray generating system consists of a Medicor Moevek Roentgengyara X-ray generator, model Neo-Diagnomax (125 kV). Measurements were taken from 50 to 90 kV. The established qualities are listed. As reference to the air kerma rate determination, a 1.0 cm3 parallel plate ionization chamber, Physikalisch-Technische Werkstaetten (PTW), model 77334, traceable to PTB, Germany, was utilized in this work. The transfer system was placed in the X-ray beams, using a Lucite holder is

  13. The LabVIEW based slow control system for the BESIII drift chamber cosmic rays test

    International Nuclear Information System (INIS)

    In the Beijing Spectrometer (BESIII) drift chamber cosmic rays test, there are hundreds of parameters need to be adjusted or set, which involves several hardware devices. The main task of slow control system is to monitor and control these parameters accurately, such as the gas rate, high voltage, voltage and current of electronics, fan speed, temperature and humidity and so on. The goal of the system is to test the construction quality of the detector and acquire a set of best parameters for it. Based on no ready-made software, we must develop a Slow Control System with the features of high flexibility and ease of use in limited time. This paper gives an introduction to the design and implementation of the LabVIEW based slow control system for the BESIII drift chamber cosmic rays test. (authors)

  14. Electronic system for the automation of current measurements produced by ionization chambers

    International Nuclear Information System (INIS)

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology in the determination of radionuclide activity. For this purpose measurements of very low ionization currents, in the range of 10-8 to 10-14 A, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. In the present work, an automation system, developed for current integration measurements at the Laboratorio de Metrologia Nuclear (LMN) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card CAD12/32 (LYNX Tecnologia Eletronica Ltda.). Measurements, using an electrometer Keithley 616 (Keithley Instruments, Inc) and an ionization chamber IG12/A20 (20th Century Electronics Ltd.), were performed in order to check the system and for validating the project. (author)

  15. A FASTBUS flash ADC system for the Mark II vertex chamber

    International Nuclear Information System (INIS)

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs

  16. The design of data acquisition system for radon chamber and its USB communication interface

    International Nuclear Information System (INIS)

    Introduction are made in the present study on the structural framework of the data acquisition system of radon chamber and the design of USB communication interface of the data acquisition system, including the design of the hardware circuit, the design of firmware, and the design of device driver. The USB communication has such characteristics as speedy transportation of information, and can be easily developed. (authors)

  17. A programming system for bubble chamber photographs measuring tables on-line to a computer

    International Nuclear Information System (INIS)

    A programming system available on an industrial computer, type PDP 15/20, performing the exploitation of bubble chamber pictures with the projection tables on line to the computer was developed. This system must suit the particular conditions met in the analysis of photographs from different bubble chambers, the different stage for dealing with the views (scanning, premeasurement, measurement) adapting to different strategies in the handling of measurements. The exploitation of photographs takes place in a conversational mode to which a concrete form is given by sending messages to the operators at the tables and by receiving coded answers. In this framework, the aims of the operating system are: to guide the operator work at the tables while allowing them to interrupt the normal sequence of events, to carry out some elementary logical checks, to write on magnetic tape the checked data with the appropriate labels as required

  18. Automation of the reading of an ionization chamber: study and design of a data transfer system

    International Nuclear Information System (INIS)

    Management of information obtained through ionization chamber, type of detector the most employed in centers or institutions using ionizing radiation machines and radioactive sources, is done manually because data are fed into computers from keyboard. This procedure presents hazards of loss and bad transcription of information. A more practical way of getting over this handicap is the setting up of a system that transfers data from ionization chamber into computer. Thereafter, it will be easier for the user to adjust his data processing software to the system underconsideration. This system, even though not directly designed to process data, that being a specific task of each user, is constituted of an electronic aspect which plays the interface part between them. It takes account parameters having relevance to the quality and the quantity of information put out by the detector

  19. Microwave remote plasma enhanced-atomic layer deposition system with multicusp confinement chamber

    International Nuclear Information System (INIS)

    A microwave remote Plasma Enhanced-Atomic Layer Deposition system with multicusp confinement chamber is established at the Plasma and Beam Physics research facilities, Chiang Mai, Thailand. The system produces highly-reactive plasma species in order to enhance the deposition process of thin films. The addition of the multicusp magnetic fields further improves the plasma density and uniformity in the reaction chamber. Thus, the system is more favorable to temperature-sensitive substrates when heating becomes unwanted. Furthermore, the remote-plasma feature, which is generated via microwave power source, offers tunability of the plasma properties separately from the process. As a result, the system provides high flexibility in choice of materials and design experiments, particularly for low-temperature applications. Performance evaluations of the system were carried on coating experiments of Al2O3 layers onto a silicon wafer. The plasma characteristics in the chamber will be described. The resulted Al2O3 films—analyzed by Rutherford Backscattering Spectrometry in channeling mode and by X-ray Photoelectron Spectroscopy techniques—will be discussed

  20. Microwave remote plasma enhanced-atomic layer deposition system with multicusp confinement chamber

    Energy Technology Data Exchange (ETDEWEB)

    Dechana, A. [Program of Physics and General Science, Faculty of Science and Technology, Songkhla Rajabhat University, Songkhla 90000 (Thailand); Thamboon, P. [Science and Technology Research Institute, Chiang Mai University, Chiang Mai 50200 (Thailand); Boonyawan, D., E-mail: dheerawan.b@cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2014-10-15

    A microwave remote Plasma Enhanced-Atomic Layer Deposition system with multicusp confinement chamber is established at the Plasma and Beam Physics research facilities, Chiang Mai, Thailand. The system produces highly-reactive plasma species in order to enhance the deposition process of thin films. The addition of the multicusp magnetic fields further improves the plasma density and uniformity in the reaction chamber. Thus, the system is more favorable to temperature-sensitive substrates when heating becomes unwanted. Furthermore, the remote-plasma feature, which is generated via microwave power source, offers tunability of the plasma properties separately from the process. As a result, the system provides high flexibility in choice of materials and design experiments, particularly for low-temperature applications. Performance evaluations of the system were carried on coating experiments of Al{sub 2}O{sub 3} layers onto a silicon wafer. The plasma characteristics in the chamber will be described. The resulted Al{sub 2}O{sub 3} films—analyzed by Rutherford Backscattering Spectrometry in channeling mode and by X-ray Photoelectron Spectroscopy techniques—will be discussed.

  1. Water hammer in the pump-rising pipeline system with an air chamber

    Institute of Scientific and Technical Information of China (English)

    KIM Sang-Gyun; LEE Kye-Bock; KIM Kyung-Yup

    2014-01-01

    Water hammer following the tripping of pumps can lead to overpressure and negative pressure. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation and to avoid fatigue of system components. The field tests on the water hammer have been conducted on the pump rising pipeline system with an air chamber. The hydraulic transient was simulated using the method of characteristics. Minimizing the least squares problem representing the difference between the measured and predicted transient response in the system performs the calibration of the simulation program. Among the input variables used in the water hammer analysis, the polytropic exponent, the discharge coefficient and the wave speed were calibrated. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system. The correct selection of air chamber size and the effect of the inner diameter of the orifice to minimize water hammer have been investigated by both field measurements and numerical modeling.

  2. A system for measuring fluxes of trace gases to and from soil and vegetation with a chamber technique

    International Nuclear Information System (INIS)

    A mobile system for measurements of gaseous fluxes of SO2 NOx, O3 and water vapour between the atmosphere and the vegetation soil system using a chamber technique is described. Equipment, instruments and instrumental sensitivities are listed. A gas-handling system including calibration procedures and information on the chamber construction is also presented. With this system it is possible to make measurements using a wide range of concentrations including subambient levels. The environment in the chamber can be kept very close to ambient conditions. The mechanisms regulating the flux can be studied. A limitation of this system is the problem of extrapolating the fluxes obtained to larger areas. (author)

  3. Optimization of working cathode position in sleeve-type bioelectrochemical system with inner chamber/outer chamber for azo dye treatment.

    Science.gov (United States)

    Kong, Fanying; Wang, Aijie; Ren, Hong-Yu

    2015-12-01

    In this study, the optimization of working cathode position in sleeve-type bioelectrochemical system (BES) was evaluated with inner/outer chamber for azo dye decolorization. Results showed that the working position in outer chamber performed better with decolorization efficiencies of 97.8 ± 2.1% (7h) and 94.0 ± 2.3% (16 h) than that in inner chamber as the volume ratio Vcathode:Vanode=1:1 and 3:1, respectively. The current and electrochemical impedance spectroscopy (EIS) analysis indicated that the proton/electron transfer and anolyte diffusion could be improved using outer chamber as working position. The decolorization with increased volume ratio could be further improved through the strategy of increasing substrate concentration, which would provide enough electrons and decrease diffusion resistance, further improving the whole performance with increased outer cathode volume. It has the great potential in sleeve-type configuration application and would create more challenges for process optimization and maintenance. PMID:26409856

  4. Characterization of Tandem systems of commercial ionization chambers for radiation dosimetry (radiotherapy level)

    CERN Document Server

    Galhardo, E P

    1998-01-01

    The use of X rays for radiotherapy purposes is of great importance for Medicine, and it is necessary to control periodically the performance of the ionization chambers and the radiation beams in order to obtain the best results. The verification of the beam characteristics is made by using standard dosimetry procedures which include the determination of the half-value layers and the exposure rates or the absorbed dose rates in air. Several Tandem systems were set up and tested, using commercial ionization chambers in the energy interval from 14 up to 130 KeV at the Instrumentation Calibration Laboratory of IPEN and at other three institutions, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The obtained results show the usefulness of these Tandem system for the routine dosimetric procedures of radiotherapy X radiation beams.

  5. Signal processing system for parallel plate ionization chamber at test beam of BEPC II

    International Nuclear Information System (INIS)

    A signal processing system has been designed in order to read out the electrode signals of 2D parallel plate ionization chamber at test beam facility of BEPC II. The system mainly includes that charge sensitive pre-amplifier, main-amplifier, analog to digital convertor and personal computer. Digital signals were recorded and displayed real time in histograms using data acquirement program based on Linux operating system. This signal processing system can be operated easily and has lower electronic noise and stable performance. (authors)

  6. Digitization and reconstruction of self-hunted streamer chamber tracks using a television system

    International Nuclear Information System (INIS)

    In this article are displayed tests on the digitization and the reconstruction of nuclear events detected in a self-shunted streamer chamber, using a television system. The light emission from such events is enough to be detected without image intensifier, but the high dynamic range of the luminosity imposes the use of a multithreshold digitization. As a consequence, a software method is implemented to find the effective profile of the tracks. (orig.)

  7. Research on fission chamber signal simulation of wide-range nuclear instrument system

    International Nuclear Information System (INIS)

    To establish an input signal to debug a digital wide-range nuclear instrument system (NIS) prototype, the research of fission chamber signal simulation was covered in this paper, which was composed of the simulation study of a pulse signal and a fluctuating current with pulse pile-up, and the signal output of the simulation results. The research is the first step to design and develop the algorithm of wide-range NIS prototype. (authors)

  8. Construction and test of a gas system for the supply of a jet chamber

    International Nuclear Information System (INIS)

    An existing test jetchamber has been made operational by the installation of an appropriate gas system. As the chamber is to study problems of the OPAL jetchamber, its gas system has to meet requirements similar to that of OPAL: Set-up of very well defined gas mixtures at given pressure, removal of residual O2 molecules and admixture of a small amount of H2O. After successful testing of the single components, measurement of the drift velocity vd was used as a functional test of the overall system. Excellent agreement has been achieved with existing OPAL drift velocity-data. (orig.)

  9. K- proton interactions at 110GeV/c in a hybrid bubble chamber system

    International Nuclear Information System (INIS)

    Preliminary work in a 2 event/microbarn (total) set of exposures of the Big European Bubble Chamber (BEBC) filled hydrogen to a beam of negative kaons of momentum 110GeV/c is described. A high energy RF separated, tagged K- beam is used. A beam tagging system is used to obtain a pure sample of K- induced reactions from the slightly impure beam. During the exposures BEBC was operated in conjuction with the External Particle Identifier (EPI), a multilayer ionisation sampling detector working in the region of the relativistic rise. The EPI is designed to identify fast hadronic secondary particles that cannot be identified in the bubble chamber, in order to reduce kinematic ambiguities. The techniques necessary to couple such a system of electronic detectors to a classical bubble chamber are described and some preliminary results illustrating the use of these techniques are presented. In addition, results on inclusive γ,K0sub(s),antilambda0,lambda0 production based on a preliminary sample of 5800 events (corresponding to 0.3 events/microbarn) of all topologies are presented, and compared with data obtained at lower energies. (author)

  10. Modeling and Simulation of Upset-Inducing Disturbances for Digital Systems in an Electromagnetic Reverberation Chamber

    Science.gov (United States)

    Torres-Pomales, Wilfredo

    2014-01-01

    This report describes a modeling and simulation approach for disturbance patterns representative of the environment experienced by a digital system in an electromagnetic reverberation chamber. The disturbance is modeled by a multi-variate statistical distribution based on empirical observations. Extended versions of the Rejection Samping and Inverse Transform Sampling techniques are developed to generate multi-variate random samples of the disturbance. The results show that Inverse Transform Sampling returns samples with higher fidelity relative to the empirical distribution. This work is part of an ongoing effort to develop a resilience assessment methodology for complex safety-critical distributed systems.

  11. Inertial confinement fusion reaction chamber and power conversion system study. Final report

    International Nuclear Information System (INIS)

    This report summarizes the results of the second year of a two-year study on the design and evaluation of the Cascade concept as a commercial inertial confinement fusion (ICF) reactor. We developed a reactor design based on the Cascade reaction chamber concept that would be competitive in terms of both capital and operating costs, safe and environmentally acceptable in terms of hazard to the public, occupational exposure and radioactive waste production, and highly efficient. The Cascade reaction chamber is a double-cone-shaped rotating drum. The granulated solid blanket materials inside the rotating chamber are held against the walls by centrifugal force. The fusion energy is captured in a blanket of solid carbon, BeO, and LiAlO2 granules. These granules are circulated to the primary side of a ceramic heat exchanger. Primary-side granule temperatures range from 1285 K at the LiAlO2 granule heat exchanger outlet to 1600 K at the carbon granule heat exchanger inlet. The secondary side consists of a closed-cycle gas turbine power conversion system with helium working fluid, operating at 1300 K peak outlet temperature and achieving a thermal power conversion efficiency of 55%. The net plant efficiency is 49%. The reference design is a plant producing 1500 MW of D-T fusion power and delivering 815 MW of electrical power for sale to the utility grid. 88 refs., 44 figs., 47 tabs

  12. Inertial confinement fusion reaction chamber and power conversion system study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Maya, I.; Schultz, K.R.; Bourque, R.F.; Cheng, E.T.; Creedon, R.L.; Norman, J.H.; Price, R.J.; Porter, J.; Schuster, H.L.; Simnad, M.J.

    1985-10-01

    This report summarizes the results of the second year of a two-year study on the design and evaluation of the Cascade concept as a commercial inertial confinement fusion (ICF) reactor. We developed a reactor design based on the Cascade reaction chamber concept that would be competitive in terms of both capital and operating costs, safe and environmentally acceptable in terms of hazard to the public, occupational exposure and radioactive waste production, and highly efficient. The Cascade reaction chamber is a double-cone-shaped rotating drum. The granulated solid blanket materials inside the rotating chamber are held against the walls by centrifugal force. The fusion energy is captured in a blanket of solid carbon, BeO, and LiAlO/sub 2/ granules. These granules are circulated to the primary side of a ceramic heat exchanger. Primary-side granule temperatures range from 1285 K at the LiAlO/sub 2/ granule heat exchanger outlet to 1600 K at the carbon granule heat exchanger inlet. The secondary side consists of a closed-cycle gas turbine power conversion system with helium working fluid, operating at 1300 K peak outlet temperature and achieving a thermal power conversion efficiency of 55%. The net plant efficiency is 49%. The reference design is a plant producing 1500 MW of D-T fusion power and delivering 815 MW of electrical power for sale to the utility grid. 88 refs., 44 figs., 47 tabs.

  13. Atmospheric scanning electron microscope system with an open sample chamber: Configuration and applications

    Energy Technology Data Exchange (ETDEWEB)

    Nishiyama, Hidetoshi, E-mail: hinishiy@jeol.co.jp [JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Koizumi, Mitsuru, E-mail: koizumi@jeol.co.jp [JEOL Technics Ltd., 2-6-38 Musashino, Akishima, Tokyo 196-0021 (Japan); Ogawa, Koji, E-mail: kogawa@jeol.co.jp [JEOL Technics Ltd., 2-6-38 Musashino, Akishima, Tokyo 196-0021 (Japan); Kitamura, Shinich, E-mail: kitamura@jeol.co.jp [JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Konyuba, Yuji, E-mail: ykonyuub@jeol.co.jp [JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Watanabe, Yoshiyuki, E-mail: watanabeyoshiy@pref.yamagata.jp [Yamagata Research Institute of Technology, 2-2-1, Matsuei, Yamagata 990-2473 (Japan); Ohbayashi, Norihiko, E-mail: n.ohbayashi@m.tohoku.ac.jp [Laboratory of Membrane Trafficking Mechanisms, Department of Developmental Biology and Neurosciences, Graduate School of Life Sciences, Tohoku University, Aobayama, Aoba-ku, Sendai, Miyagi 980-8578 (Japan); Fukuda, Mitsunori, E-mail: nori@m.tohoku.ac.jp [Laboratory of Membrane Trafficking Mechanisms, Department of Developmental Biology and Neurosciences, Graduate School of Life Sciences, Tohoku University, Aobayama, Aoba-ku, Sendai, Miyagi 980-8578 (Japan); Suga, Mitsuo, E-mail: msuga@jeol.co.jp [JEOL Ltd., 3-1-2, Musashino, Akishima, Tokyo 196-8558 (Japan); Sato, Chikara, E-mail: ti-sato@aist.go.jp [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-4, Umezono, Tsukuba 305-8568 (Japan)

    2014-12-15

    An atmospheric scanning electron microscope (ASEM) with an open sample chamber and optical microscope (OM) is described and recent developments are reported. In this ClairScope system, the base of the open sample dish is sealed to the top of the inverted SEM column, allowing the liquid-immersed sample to be observed by OM from above and by SEM from below. The optical axes of the two microscopes are aligned, ensuring that the same sample areas are imaged to realize quasi-simultaneous correlative microscopy in solution. For example, the cathodoluminescence of ZnO particles was directly demonstrated. The improved system has (i) a fully motorized sample stage, (ii) a column protection system in the case of accidental window breakage, and (iii) an OM/SEM operation system controlled by a graphical user interface. The open sample chamber allows the external administration of reagents during sample observation. We monitored the influence of added NaCl on the random motion of silica particles in liquid. Further, using fluorescence as a transfection marker, the effect of small interfering RNA-mediated knockdown of endogenous Varp on Tyrp1 trafficking in melanocytes was examined. A temperature-regulated titanium ASEM dish allowed the dynamic observation of colloidal silver nanoparticles as they were heated to 240 °C and sintered. - Highlights: • Atmospheric SEM (ASEM) allows observation of samples in liquid or gas. • Open sample chamber allows in situ monitoring of evaporation and sintering processes. • in situ monitoring of processes during reagent administration is also accomplished. • Protection system for film breakage is developed for ASEM. • Usability of ASEM has been improved significantly including GUI control.

  14. Performance of an image analysis processing system for hen tracking in an environmental preference chamber.

    Science.gov (United States)

    Kashiha, Mohammad Amin; Green, Angela R; Sales, Tatiana Glogerley; Bahr, Claudia; Berckmans, Daniel; Gates, Richard S

    2014-10-01

    Image processing systems have been widely used in monitoring livestock for many applications, including identification, tracking, behavior analysis, occupancy rates, and activity calculations. The primary goal of this work was to quantify image processing performance when monitoring laying hens by comparing length of stay in each compartment as detected by the image processing system with the actual occurrences registered by human observations. In this work, an image processing system was implemented and evaluated for use in an environmental animal preference chamber to detect hen navigation between 4 compartments of the chamber. One camera was installed above each compartment to produce top-view images of the whole compartment. An ellipse-fitting model was applied to captured images to detect whether the hen was present in a compartment. During a choice-test study, mean ± SD success detection rates of 95.9 ± 2.6% were achieved when considering total duration of compartment occupancy. These results suggest that the image processing system is currently suitable for determining the response measures for assessing environmental choices. Moreover, the image processing system offered a comprehensive analysis of occupancy while substantially reducing data processing time compared with the time-intensive alternative of manual video analysis. The above technique was used to monitor ammonia aversion in the chamber. As a preliminary pilot study, different levels of ammonia were applied to different compartments while hens were allowed to navigate between compartments. Using the automated monitor tool to assess occupancy, a negative trend of compartment occupancy with ammonia level was revealed, though further examination is needed. PMID:25071227

  15. Atmospheric scanning electron microscope system with an open sample chamber: Configuration and applications

    International Nuclear Information System (INIS)

    An atmospheric scanning electron microscope (ASEM) with an open sample chamber and optical microscope (OM) is described and recent developments are reported. In this ClairScope system, the base of the open sample dish is sealed to the top of the inverted SEM column, allowing the liquid-immersed sample to be observed by OM from above and by SEM from below. The optical axes of the two microscopes are aligned, ensuring that the same sample areas are imaged to realize quasi-simultaneous correlative microscopy in solution. For example, the cathodoluminescence of ZnO particles was directly demonstrated. The improved system has (i) a fully motorized sample stage, (ii) a column protection system in the case of accidental window breakage, and (iii) an OM/SEM operation system controlled by a graphical user interface. The open sample chamber allows the external administration of reagents during sample observation. We monitored the influence of added NaCl on the random motion of silica particles in liquid. Further, using fluorescence as a transfection marker, the effect of small interfering RNA-mediated knockdown of endogenous Varp on Tyrp1 trafficking in melanocytes was examined. A temperature-regulated titanium ASEM dish allowed the dynamic observation of colloidal silver nanoparticles as they were heated to 240 °C and sintered. - Highlights: • Atmospheric SEM (ASEM) allows observation of samples in liquid or gas. • Open sample chamber allows in situ monitoring of evaporation and sintering processes. • in situ monitoring of processes during reagent administration is also accomplished. • Protection system for film breakage is developed for ASEM. • Usability of ASEM has been improved significantly including GUI control

  16. Improvement of the drift chamber system in the SAPHIR detector and first measurements of the Φ meson production at threshold

    International Nuclear Information System (INIS)

    The SAPHIR detector at ELSA enables the measurement of photon induced Φ meson production from threshold up to 3 GeV in the full kinematical range. A considerable improvement of the drift chamber system is a precondition of gaining the necessary data rate in an acceptable time. The research focuses attention on the choice of the chamber gas and on a different mechanical construction, so as to minimize the negative influences of the photon beam crossing the sensitive volume of the drift chamber system. In addition, first preliminary results of the total and the differential cross section for the Φ meson production close to threshold were evaluated. (orig.)

  17. Analysis of the Radiated Field in an Electromagnetic Reverberation Chamber as an Upset-Inducing Stimulus for Digital Systems

    Science.gov (United States)

    Torres-Pomales, Wilfredo

    2012-01-01

    Preliminary data analysis for a physical fault injection experiment of a digital system exposed to High Intensity Radiated Fields (HIRF) in an electromagnetic reverberation chamber suggests a direct causal relation between the time profile of the field strength amplitude in the chamber and the severity of observed effects at the outputs of the radiated system. This report presents an analysis of the field strength modulation induced by the movement of the field stirrers in the reverberation chamber. The analysis is framed as a characterization of the discrete features of the field strength waveform responsible for the faults experienced by a radiated digital system. The results presented here will serve as a basis to refine the approach for a detailed analysis of HIRF-induced upsets observed during the radiation experiment. This work offers a novel perspective into the use of an electromagnetic reverberation chamber to generate upset-inducing stimuli for the study of fault effects in digital systems.

  18. Design and construction of automatic operating system of double chamber plasma nitriding device PLC based

    International Nuclear Information System (INIS)

    The automatic operating system of double chamber plasma nitriding device has been done. The system is used for operating double chamber plasma nitriding automatically as according to the standard operating procedure by pressing push button on the human machine interface (HMI). The system consists of hardware and software. The hardware was constructed using main components T100MD1616+ PLC module and supported by temperature signal conditioner module, Wheatstone bridge module, isolated amplifier module and EMS 30A H Bridge motor driver module. A software program that is planted on T100MD1616+ PLC using ladder diagrams and Tbasic program. Test system functions performed by inserting a set values of temperature and pressure by pressing the button on the human machine interface (HMI). The test results show that the temperature control with a set of values 100 °C obtained stable coverage of 98 °C to 102 °C, (Δ ± 2 °C) with a 2% tolerance and the output voltage of the DAC is 2.436 volts to 2.913 volts. The pressure control with a set of values 2.169 x 10-1 mbar obtained stable coverage of 1.995 x 10-1 mbar to 2.205 x 10-1 mbar, (Δ ± 0.105 x 10-1 mbar) with a 5% tol. (author)

  19. Clinical applications of a high speed matrix ionization chamber portal imaging system

    International Nuclear Information System (INIS)

    A main disadvantage of the present matrix ionization chamber system for electronic portal imaging is its relatively slow image acquisition of 6 s at full resolution. We have solved this problem by modifying the read-out electronics in two ways: First, faster high voltage switches are applied which work with a higher voltage; Second, faster read-out amplifiers are applied which have reduced cross-talk. With these improvements circuit noise is no longer dominant at typical radiotherapy dose rates. Because the quantum noise level in the matrix ionization chamber system is purely determined by signal integration in the liquid medium, the image scan can now be reduced to as short as 0.55 s with little loss of image quality. However, there is some loss of resolution at readout speed faster than 1.5 s due to speed limitations of the read-out amplifiers. One of the applications of the new device is double exposures for larynx fields. At a reduced dose rate of 125 MU/min, only about 5 MUs are required for a single frame on a 4 MV ABB Dynaray accelerator. Other applications which benefit from the reduced image scan time are time lapse movies. Typically 15 frames per field are made during one fraction. The movies offer both information on patient motion and improved image quality by averaging the frames. Finally, on-line analysis of the images can be performed more easily and has been included in the software package. In can be concluded that the higher speed of the new matrix ionization chamber system is an important improvement for several clinical applications

  20. Expert System for the LHC CMS Cathode Strip Chambers (CSC) detector

    Energy Technology Data Exchange (ETDEWEB)

    Rapsevicius, Valdas, E-mail: valdas.rapsevicius@cern.ch [Fermi National Accelerator Laboratory, Batavia, IL (United States); Vilnius University, Didlaukio g. 47-325, LT-08303 Vilnius (Lithuania); Juska, Evaldas, E-mail: evaldas.juska@cern.ch [Fermi National Accelerator Laboratory, Batavia, IL (United States)

    2014-02-21

    Modern High Energy Physics experiments are of high demand for a generic and consolidated solution to integrate and process high frequency data streams by applying experts' knowledge and inventory configurations. In this paper we present the Expert System application that was built for the Compact Muon Solenoid (CMS) Cathode Strip Chambers (CSC) detector at the Large Hadron Collider (LHC) aiming to support the detector operations and to provide integrated monitoring. The main building blocks are the integration platform, rule-based complex event processing engine, ontology-based knowledge base, persistent storage and user interfaces for results and control.

  1. New assembly of ionization chambers for the RBMK reactor control systems

    International Nuclear Information System (INIS)

    A new assembly consisting of ionization chambers (IC) and cables is developed for the RBMK reactor control systems (RCS). The assembly together with the channel of RCS ensures reliable power control in the range from 10-10 to 1.5 nominal power and measuring the neutron flux density in the reactor core height. The design of the assembly with IC is presented. Tests showed that the new IC assembly provides high sensitivity of measurements and RCS channel noise immunity in all range of reactor power variation

  2. Commissioning of a 20 K Helium Refrigeration System for NASA-JSC Chamber A

    Science.gov (United States)

    Homan, J.; Redman, R.; Ganni, V.; Sidi-Yekhlef, A.; Knudsen, P.; Norton, R.; Lauterbach, J.; Linza, R.; Vargas, G.

    2013-01-01

    A new 20 K helium refrigerator installed at NASA Johnson Space Center s Space Environment Simulation Laboratory (SESL) was successfully commissioned and tested in 2012. The refrigerator is used to create a deep space environment within SESL s Chamber A to perform ground testing of the James Webb Space Telescope (JWST). The chamber previously and currently still has helium cryo-pumping panels (CPP) and liquid nitrogen shrouds used to create low earth orbit environments. Now with the new refrigerator and new helium shrouds the chamber can create a deep space environment. The process design, system analysis, specification development, and commissioning oversight were performed by the cryogenics department at Jefferson Lab, while the contracts and system installation was performed by the ESC group at JSC. Commissioning data indicate an inverse coefficient of performance better than 70 W/W for a 18 kW load at 20 K (accounting for liquid nitrogen pre-cooling power) that remains essentially constant down to one third of this load. Even at 10 percent of the maximum capacity, the performance is better than 150 W/W at 20 K. The refrigerator exceeded all design goals and demonstrated the ability to support a wide load range from 10 kW at 15 K to 100 kW at 100 K. The refrigerator is capable of operating at any load temperature from 15 K to ambient with tight temperature stability. The new shroud (36 tons of aluminum) can be cooled from room temperature to 20 K in 24 hours. This paper will outline the process design and commissioning results.

  3. 20 K Helium Refrigeration System for NASA-JSC Chamber-A

    Science.gov (United States)

    Homan, J.; Redman, R.; Ganni, V.; Sidi-Yekhelef, A.; Knudsen, P.; Norton, R.; Lauterbach, J.; Linza, R.; Vargas, G.

    2013-01-01

    A new 20 K helium refrigerator installed at NASA Johnson Space Center's Space Environment Simulation Laboratory (SESL) was successfully commissioned and tested in 2012. The refrigerator is used to create a deep space environment within SESL s Chamber A to perform ground testing of the James Webb Space Telescope. The chamber previously and currently still has helium cryopumping panels (CPP) and LN2 shrouds used to create Low Earth Orbit environments. Now with the new refrigerator and new helium shrouds (45 x 65 ) the chamber can create a deep space environment. The process design, system analysis, specification development, and commissioning oversight were performed by the cryogenics department at Jefferson Labs, while the contracts and system installation was performed by the ESC group at JSC. Commissioning data indicate a inverse coefficient of performance better than 70 W/W for a 18 KW load at 20 K (accounting for liquid nitrogen precooling power) that remains essentially constant down to 1/3 of this load. Even at 10 percent of the maximum capacity, the performance is better than 140 W/W at 20K. The refrigerator exceeded all design goals and demonstrated the ability to support a wide load range from 10kW at 15 K to 100 kW at 100K. The refrigerator is capable of operating at any load temperature from 15K to ambient with tight temperature stability. The new shroud (36 tons of aluminum) can be cooled from room temperature to 20 K in 24 hours. This paper will outline the process design and commissioning results.

  4. ITER cryostat main chamber and vacuum vessel pressure suppression system design

    International Nuclear Information System (INIS)

    Design of Cryostat Main Chamber and Vacuum Vessel Pressure Suppression System (VVPS) of International Thermonuclear Experimental Reactor (ITER) has been conducted. The cryostat is a cylindrical vessel that includes in-vessel component such as vacuum vessel, superconducting toroidal coils and poloidal coils. This cryostat provides the adiabatic vacuum about 10-4 Pa for the superconducting coils operating at 4 K and forms the second confinement barrier to tritium. The adiabatic vacuum is to reduce thermal loads applied to the superconducting coils and their supports so as to keep their temperature 4 K. The VVPS consists of a suppression tank located under the lower bio-shield and 4 relief pipes to connect the vacuum vessel and the suppression tank. The VVPS is to keep the maximum pressure rise of the vacuum vessel below the design value of 0.5 MPa in case of the in-vessel LOCA (water spillage from in-vessel component). The spilled water and steam are lead to the suppression tank through the relief pipes when the internal pressure of vacuum vessel is over 0.2 MPa, and then the internal pressure is kept below 0.5 MPa. This report summarizes the structural design of the cryostat main chamber and pressure suppression system, together with their fabrication and installation. (author)

  5. ITER cryostat main chamber and vacuum vessel pressure suppression system design

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Akira; Nakahira, Masataka; Takahashi, Hiroyuki; Tada, Eisuke [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakashima, Yoshitane; Ueno, Osamu

    1999-03-01

    Design of Cryostat Main Chamber and Vacuum Vessel Pressure Suppression System (VVPS) of International Thermonuclear Experimental Reactor (ITER) has been conducted. The cryostat is a cylindrical vessel that includes in-vessel component such as vacuum vessel, superconducting toroidal coils and poloidal coils. This cryostat provides the adiabatic vacuum about 10{sup -4} Pa for the superconducting coils operating at 4 K and forms the second confinement barrier to tritium. The adiabatic vacuum is to reduce thermal loads applied to the superconducting coils and their supports so as to keep their temperature 4 K. The VVPS consists of a suppression tank located under the lower bio-shield and 4 relief pipes to connect the vacuum vessel and the suppression tank. The VVPS is to keep the maximum pressure rise of the vacuum vessel below the design value of 0.5 MPa in case of the in-vessel LOCA (water spillage from in-vessel component). The spilled water and steam are lead to the suppression tank through the relief pipes when the internal pressure of vacuum vessel is over 0.2 MPa, and then the internal pressure is kept below 0.5 MPa. This report summarizes the structural design of the cryostat main chamber and pressure suppression system, together with their fabrication and installation. (author)

  6. Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

    International Nuclear Information System (INIS)

    The CEBAF Large Acceptance Spectrometer (CLAS) is a superconducting toroidal magnet with a large volume of drift chambers for charged particle tracking. The performance of these chambers depends on accurate monitoring and control of the mixture, flow rate, pressure, temperature, and contaminant levels of the gas. To meet these requirements, a control system is being developed with EPICS. The interface hardware consists of VME ADCs and three RS-232 low-level hardware controllers. The RS-232 instruments include MKS 647A mass flow controllers to control and monitor the gas mixture and flow, MKS 146B pressure gauge controllers to measure pressures, and a Panametrics hygrometer to monitor temperatures and the concentrations of oxygen, water vapor, and ethane. Many of the parameters are available as analog signals which will be monitored with XYCOM VME analog input cards and configured for alarms and data logging. The RS-232 interfaces will be used for remote control of the hardware and verification of the analog readings. Information will be passed quickly and efficiently to and from the user through a graphical user interface. A discussion of the requirements and design of the system is presented

  7. Multi-dimensional scattering properties diagnosis system of scale aircraft model in an anechoic chamber

    Institute of Scientific and Technical Information of China (English)

    Chufeng Hu; Zhou Zhou; Nanjing Li; Kun Zhang

    2014-01-01

    Aiming at the concept of “diagnosis”, a simple and ef-fective broadband radar cross section (RCS) measurement system is constructed, and some multi-dimensional scattering properties diagnosis techniques are presented based on the system. Firstly, a stepped-frequency signal is employed to achieve high range resolution, combining with a variety of signal processing tech-niques. Secondly, cross-range resolution is gained with a rotating table, and the high-resolution two-dimensional (2-D) imaging of the scale model is obtained by the microwave imaging theory. Fi-nal y, two receiving antennas with a smal distance in altitude are used, and the three-dimensional (3-D) height distribution of scattering points on the scale model is extracted from the phase of images. Some typical bodies and a scale aircraft model are diagnosed in an anechoic chamber. The experimental results show that, after scaling with a metal sphere, the accurate one-dimensional (1-D) RCS pattern of the model is obtained, and it has a large dynamic range. When the bandwidth of the transmit-ting signal is 4 GHz, the resolution of the 2-D image can reach to 0.037 5 m. The 3-D height distribution of scattering points is given by interferometric measurement. This paper provides a feasible way to obtain high-precision scattering properties parameters of the scale aircraft model in a conventional rectangular anechoic chamber.

  8. Resistive plate chamber (RPC) based muon trigger system for the CMS experiment - data compression/decompression system

    International Nuclear Information System (INIS)

    The CMS detector will have a dedicated subdetector (RPC chambers) to identify muons, measure their transverse momenta pt, and determine the bunch crossings from which they originate. The trigger algorithm is based on muon track search and classification in raw data from the RPC chambers grouped in the four muon stations in the CMS magnet yoke. A huge interconnection network is needed to fulfill this task. It can be built in the control room only, approximately 120 m away from the detector. The data compression/decompression system is proposed to reduce the number of links needed to transfer the data from detector to control room. The idea of such a system and results of first tests will be presented. (author)

  9. Improving the gas gain monitoring system in multiwire proportional chambers for MUON detector of LHCb experiment.

    CERN Document Server

    Ruvinskaia, Ekaterina

    2016-01-01

    The gas gain monitoring system in multi-wire proportional chambers for MUON detector of LHCb has been constructed and commissioned. It includes an online- monitoring, tools for analysis the archived data and an alarm system on the quality of the gas mixture. Finally, it will be implemented in the main ECS of LHCb for MUON detector and as a part of safety system of LHCb as a permanent online monitor of the quality of the gas mixture in MWPCs. The main advantage of this setup is a monitoring of Gas Gain (GG) in MWPCs with radioactive sources independently from the presence of beam at LHC. It also provides an option for prompt reaction in case of a problem with the gas.

  10. Quality assurance of proton beams using a multilayer ionization chamber system

    International Nuclear Information System (INIS)

    Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF

  11. A Tale of Two Chambers: Iterative Approaches and Lessons Learned from Life Support Systems Testing in Altitude Chambers

    Science.gov (United States)

    Callini, Gianluca

    2016-01-01

    With a brand new fire set ablaze by a serendipitous convergence of events ranging from a science fiction novel and movie ("The Martian"), to ground-breaking recent discoveries of flowing water on its surface, the drive for the journey to Mars seems to be in a higher gear than ever before. We are developing new spacecraft and support systems to take humans to the Red Planet, while scientists on Earth continue using the International Space Station as a laboratory to evaluate the effects of long duration space flight on the human body. Written from the perspective of a facility test director rather than a researcher, and using past and current life support systems tests as examples, this paper seeks to provide an overview on how facility teams approach testing, the kind of information they need to ensure efficient collaborations and successful tests, and how, together with researchers and principal investigators, we can collectively apply what we learn to execute future tests.

  12. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x108 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  13. Two-dimensional electronic readout system for multi-step-avalanche chambers

    International Nuclear Information System (INIS)

    We present prototype studies of a new technical solution of detector readout for measurements of charged particles at very high particle densities. In particular, this paper describes a readout system for multi-step avalanche chambers designed for the WA98 experiment at the CERN SPS. Results from the prototype studies are used for the design parameters of a readout chip containing both analog and digital functions. Simulations of the final system show that the position of the electron cloud can be reconstructed for single particles to an accuracy of 100 and 300 μm in the horizontal and vertical directions, respectively. Separation of two tracks about 5 mm apart is also obtained from the simulation. (orig.)

  14. A readout system for a cosmic ray telescope using Resistive Plate Chambers

    International Nuclear Information System (INIS)

    Resistive Plate Chambers (RPCs) are widely used in high energy physics for both tracking and triggering purposes. They have good time resolution and with finely segmented readout can also give a spatial resolution of better than 1 mm. RPCs can be produced cost-effectively on large scales, are of rugged build, and have excellent detection efficiency for charged particles. Our group has successfully built a Muon Scattering Tomography (MST) prototype, using 12 RPCs to obtain tracking information of muons going through a target volume of ∼ 50 cm × 50 cm × 70 cm, reconstructing both the incoming and outgoing muon tracks. We describe a readout system for fine-pitch RPCs using MAROC3 readout chips capable of scaling to a large system.

  15. Two-dimensional electronic readout system for multi-step-avalanche chambers

    Energy Technology Data Exchange (ETDEWEB)

    Carlen, L. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Garpman, S. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Gustafsson, H.-Aa. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Loehner, H. [Kernfysisch Versneller Instituut, Zernikelaan 25, Nl-9747 AA Groningen (Netherlands); Nystrand, J. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Oskarsson, A. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Otterlund, I. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Svensson, T. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Stenlund, E. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Soederstroem, K. [Lund Univ. (Sweden). Div. of Cosmic and Subatomic Phys.; Whitlow, H.J. [Department of Nuclear Physics, Lund Institute of Technology, Soelvegatan 14, S-223 62 Lund (Sweden)

    1997-06-11

    We present prototype studies of a new technical solution of detector readout for measurements of charged particles at very high particle densities. In particular, this paper describes a readout system for multi-step avalanche chambers designed for the WA98 experiment at the CERN SPS. Results from the prototype studies are used for the design parameters of a readout chip containing both analog and digital functions. Simulations of the final system show that the position of the electron cloud can be reconstructed for single particles to an accuracy of 100 and 300 {mu}m in the horizontal and vertical directions, respectively. Separation of two tracks about 5 mm apart is also obtained from the simulation. (orig.).

  16. Technical realization of a closure concept for a chamber-system in the underground Richard repository in the Czech Republic

    International Nuclear Information System (INIS)

    The Phare project CZ 632.02.04 'Realization of closure of a chamber in the Richard repository as input for establishing a safety case' is a follow up implementation phase of the Phare project, CZ 01.14.03 'Solution for closure of a chamber in the Richard repository'. Main objective of both projects is to propose and realize a disposal system in selected chambers of the Richard repository, which will eliminate burden from the past practices in waste management during the first phase of the Richard repository operation (1965 - 1980) and which will improve its overall long term safety. This objective will be assured by realization of the concept of so called 'hydraulic cage', which technical solution was developed by DBE Technology within the Phare project CZ 01.14.03. The solution is described in the previous presentation 'Hydraulic Cage Concept for Waste Chambers and its Technical Implementation for the Underground Richard Repository, Litomerice, Czech Republic'. (author)

  17. Simulation study on a solar desalination system utilizing an evaporator/condenser chamber

    International Nuclear Information System (INIS)

    A solar desalination system consisting of a solar collector coupled to an evaporation/condensation chamber, all components fabricated from polymeric materials, has been developed and tested. A simulation model of the desalination system has been developed and validated by inter-comparison with experimental measurements on such a system. The simulation model employs a numerical solution to a set of differential equations describing the system. The validated simulation model was then utilized to perform parametric sensitivity studies to determine optimum design parameters and operation conditions. It was found that a solar desalination system, based upon the prototype studied, is capable of producing in excess of 11 kg m-2 d-1 of distillate on a sunny day when the gap between the evaporator and condenser surfaces is of the order of 2 cm, and the feedstock flow rate is within the range of 40-50 kg m-2 d-1. Such a corrosion resistant desalination system would be ideal for desalination of seawater. The results of the performance testing, simulation model validation and parametric sensitivity studies on the prototype module are reported

  18. Classical behavior in quantum systems: the case of straight tracks in a cloud chamber

    CERN Document Server

    Teta, Alessandro

    2009-01-01

    The aim of this review is to discuss in a pedagogical way the problem of the emergence of a classical behavior in certain physical systems which, in principle, are correctly described by quantum mechanics. It is stressed that the limit $\\hbar \\to 0$ is not sufficient and the crucial role played by the environment must be taken into account. In particular it is recalled the old problem raised by Mott in 1929 (\\cite{m}) concerning the straight tracks observed in a cloud chamber, produced by an $\\alpha$-particle emitted by a source in the form of a spherical wave. The conceptual relevance of the problem for a clearer understanding of the classical limit is discussed in a historical perspective. Moreover a simple mathematical model is proposed, where the result of Mott is obtained in a rigorous mathematical way.

  19. Laser measuring system for incremental assemblies. [measuring wire-wrapped frame assemblies in spark chambers

    Science.gov (United States)

    Etzel, J. G.; Munford, J. A. (Inventor)

    1981-01-01

    Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

  20. A reference current source for the calibration of current measuring systems in dosimetry using ionisation chambers

    International Nuclear Information System (INIS)

    This work describes a newly developed, easily handled current source containing one 90Sr + 90Y Y beta emitter. Four different currents from 7x10-11A to 4x10-14A are supplied. From 5 to 10 control measurements were performed for each of the four currents during a period of eight months. The standard deviation of the values of these control measurements, corrected to a reference air density and for radioactive decay, was between 0,07% and 0,4% with respect to the mean values obtained during the eight months. The relative standard deviation of the single values belonging to a control measurement carried out on one day under constant ambient conditions amounts to approximately one fourth of the values quoted above. The current source was utilized in a number of laboratories in the PTB and proved its reliability for checking current measuring systems in dosimetry with ionization chambers. (orig.)

  1. A proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    The authors have developed and extensively used a PWC system in precision measurements of total cross sections at low momenta (0.4-1.1 GeV/c) and at high momenta (23-370 GeV/c). This 'electronic collimator' operated simultaneously in a fast (250 ns) decision making mode, and a slower (0.5 ms) readout mode. The decision making mode utilized adjustable hardwired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events was read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure. (Auth.)

  2. Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

    Science.gov (United States)

    Martin, J. J.; Bragg-Sitton, S. M.; Reid, R. S.; Stewart, E. T.; Davis, J. D.

    2011-01-01

    A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

  3. Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system

    Institute of Scientific and Technical Information of China (English)

    Ibrahim; Kocak; Funda; Kocak; Bahri; Teker; Ali; Aydin; Faruk; Kaya; Hakan; Baybora

    2014-01-01

    ·AIM: To assess the incidence of anterior chamber bacterial contamination during phacoemulsification surgery using an automated microbial detection system(BacT/Alert).·METHODS: Sixty-nine eyes of 60 patients who had uneventful phacoemulsification surgery, enrolled in this prospective study. No prophylactic topical or systemic antibiotics were used before surgery. After antisepsis with povidone-iodine, two intraoperative anterior chamber aqueous samples were obtained, the first whilst entering anterior chamber, and the second at the end of surgery. BacT/Alert culture system was used to detect bacterial contamination in the aqueous samples.·RESULTS: Neither aqueous samples obtained at the beginning nor conclusion of the surgery was positive for microorganisms on BacT/Alert culture system. The rate of bacterial contamination during surgery was 0%. None of the eyes developed acute-onset endophthalmitis after surgery.· CONCLUSION: In this study, no bacterial contamination of anterior chamber was observed during cataract surgery. This result shows that meticulous surgical preparation and technique can prevent anterior chamber contamination during phacoemulsification cataract surgery.

  4. Advanced control system for the scattering chamber of K-130 cyclotron

    International Nuclear Information System (INIS)

    The old relay based position control system of the Scattering Chamber of K-130 Cyclotron was more than 30 years old, developed multiple problems over the years, and the components of the control system like relays, potentiometers, limit switches, radiation resistant cables were not functioning as per specifications. It has been replaced recently by a new PLC based embedded control system. This has been developed using Advantech ADAM-5510EKW 16 bit CPU together with required I/O modules. MULTIPROG Basic V.4.6 has been used as programming software and Ladder Diagram has been used to realize control scheme of the PLC. A resistive type touch screen based operator panel, WebOP-2104VN4AE has been mounted on the control rack for local control. iFIX SCADA, 75 tags Runtime Version 5.1 has been used to operate from remote PC connected to the PLC by 70m CAT6 cable. The PLC communicates with the touch panel and remote PC through 100 Mbps Ethernet switch. The Graphical User Interfaces of the local control panel and the remote panel have been developed as per the requirement from the users. All the old sensors, limit switches, relays and cables have been replaced by new items. This paper reports about the development and commissioning of basic hardware, software and operation of the control system for last six months. (author)

  5. Construction and manufacture of large size straw-chambers of the COMPASS spectrometer tracking system

    International Nuclear Information System (INIS)

    We report the construction and preliminary testing of 3.6 and 3.2 m long straw tube drift chambers consisting of 672 and 864 channels, respectively. The design considerations, the development of several new techniques are described. The 15 two-layer straw drift chambers have been built for the experiment COMPASS at CERN

  6. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  7. Front-end readout electronics considerations for Silicon Tracking System and Muon Chamber

    International Nuclear Information System (INIS)

    Silicon Tracking System (STS) and Muon Chamber (MUCH) are components of the Compressed Baryonic Matter (CBM) experiment at FAIR, Germany. STS will be built from 8 detector stations located in the aperture of the magnet. Each station will be built from double-sided silicon strip detectors and connected via kapton microcables to the readout electronics at the perimeter of each station. The challenging physics program of the CBM experiment requires from the detector systems very high performance. Design of the readout ASIC requires finding an optimal solution for interaction time and input charge measurements in the presence of: tight area (channel pitch: 58 μ m), noise (< 1000 e- rms), power (< 10 mW/channel), radiation hardness and speed requirements (average hit rate: 250 khit/s/channel). This paper presents the front-end electronics' analysis towards prototype STS and MUCH readout ASIC implementation in the UMC 180 nm CMOS process and in-system performance with the emphasis on preferable detector and kapton microcable parameters and input amplifiers' architecture and design

  8. Study on the stability of waterpower-speed control system for hydropower station with air cushion surge chamber

    Science.gov (United States)

    Guo, W. C.; Yang, J. D.; Chen, J. P.; Teng, Y.

    2014-03-01

    According to the fact that the effects of penstock, unit and governor on stability of water level fluctuation for hydropower station with air cushion surge chamber are neglected in previous researches, in this paper, Thoma assumption is broken through, the complete mathematical model of waterpower-speed control system for hydropower station with air cushion surge chamber is established, and the comprehensive transfer function and linear homogeneous differential equation that characterize the dynamic characteristics of system are derived. The stability domain that characterizes the good or bad of stability quantitatively is drawn by using the stability conditions. The effects of the fluid inertia in water diversion system, the air cushion surge chamber parameters, hydraulic turbine characteristics, generator characteristics, and regulation modes of governor on the stability of waterpower-speed control system are analyzed through stability domain. The main conclusions are as follows: The fluid inertia in water diversion system and hydraulic turbine characteristics have unfavorable effects on the system while generator characteristics have favorable effect. The stability keeps getting better with the increase of chamber height and basal area and the decrease of air pressure and air polytropic exponent. The stability of power regulation mode is obviously better than that of frequency regulation mode.

  9. Study on the stability of waterpower-speed control system for hydropower station with air cushion surge chamber

    International Nuclear Information System (INIS)

    According to the fact that the effects of penstock, unit and governor on stability of water level fluctuation for hydropower station with air cushion surge chamber are neglected in previous researches, in this paper, Thoma assumption is broken through, the complete mathematical model of waterpower-speed control system for hydropower station with air cushion surge chamber is established, and the comprehensive transfer function and linear homogeneous differential equation that characterize the dynamic characteristics of system are derived. The stability domain that characterizes the good or bad of stability quantitatively is drawn by using the stability conditions. The effects of the fluid inertia in water diversion system, the air cushion surge chamber parameters, hydraulic turbine characteristics, generator characteristics, and regulation modes of governor on the stability of waterpower-speed control system are analyzed through stability domain. The main conclusions are as follows: The fluid inertia in water diversion system and hydraulic turbine characteristics have unfavorable effects on the system while generator characteristics have favorable effect. The stability keeps getting better with the increase of chamber height and basal area and the decrease of air pressure and air polytropic exponent. The stability of power regulation mode is obviously better than that of frequency regulation mode

  10. Design and experimental study of an integrated vapor chamber-thermal energy storage system

    Science.gov (United States)

    Kota, Krishna M.

    Future defense, aerospace and automotive technologies involve electronic systems that release high pulsed waste heat like during high power microwave and laser diode applications in tactical and combat aircraft, and electrical and electronic systems in hybrid electric vehicles, which will require the development of an efficient thermal management system. A key design issue is the need for fast charging so as not to overheat the key components. The goal of this work is to study the fabrication and technology implementation feasibility of a novel high energy storage, high heat flux passive heat sink. Key focus is to verify by theory and experiments, the practicability of using phase change materials as a temporary storage of waste heat for heat sink applications. The reason for storing the high heat fluxes temporarily is to be able to reject the heat at the average level when the heat source is off. Accordingly, a concept of a dual latent heat sink intended for moderate to low thermal duty cycle electronic heat sink applications is presented. This heat sink design combines the features of a vapor chamber with rapid thermal energy storage employing graphite foam inside the heat storage facility along with phase change materials and is attractive owing to its passive operation unlike some of the current thermal management techniques for cooling of electronics employing forced air circulation or external heat exchangers. In addition to the concept, end-application dependent criteria to select an optimized design for this dual latent heat sink are presented. A thermal resistance concept based design tool/model has been developed to analyze and optimize the design for experiments. The model showed that it is possible to have a dual latent heat sink design capable of handling 7 MJ of thermal load at a heat flux of 500 W/cm2 (over an area of 100 cm 2) with a volume of 0.072 m3 and weighing about 57.5 kg. It was also found that with such high heat flux absorption capability

  11. On the Interaction of a Vigorous Hydrothermal System with an Active Magma Chamber: The Puna Magma Chamber, Kilauea East Rift, Hawaii

    Science.gov (United States)

    Gregory, R. T.; Marsh, B. D.; Teplow, W.; Fournelle, J.

    2009-12-01

    The extent of the interaction between hydrothermal systems and active magma chambers has long been of fundamental interest to the development of ore deposits, cooling of magma chambers, and dehydration of the subducting lithosphere. As volatiles build up in the residual magma in the trailing edge of magmatic solidification fronts, is it possible that volatiles are transferred from the active magma to the hydrothermal system and vice versa? Does the external fracture front associated with vigorous hydrothermal systems sometimes propagate into the solidification front, facilitating volatile exchange? Or is the magma always sealed at temperatures above some critical level related to rock strength and overpressure? The degree of hydrothermal interaction in igneous systems is generally gauged in post mortem studies of δ18O and δD, where it has been assumed that a fracture front develops about the magma collapsing inward with cooling. H.P. Taylor and D. Norton's (1979; J. Petrol.)seminal work inferred that rocks are sealed with approach to the solidus and there is little to no direct interaction with external volatiles in the active magma. In active lava lakes a fracture front develops in response to thermal contraction of the newly formed rock once the temperature drops to ~950°C (Peck and Kinoshita,1976;USGS PP935A); rainfall driven hydrothermal systems flash to steam near the 100 °C isotherm in the solidified lake and have little effect on the cooling history (Peck et al., 1977; AJS). Lava lakes are fully degassed magmas and until the recent discovery of the Puna Magma Chamber (Teplow et al., 2008; AGU) no active magma was known at sufficiently great pressure to contain original volatiles. During the course of routine drilling of an injection well at the Puna Geothermal Venture (PGV) well-field, Big Island, Hawaii, a 75-meter interval of diorite containing brown glass inclusions was penetrated at a depth of 2415 m, continued drilling to 2488 m encountered a melt

  12. Chamber transport

    Energy Technology Data Exchange (ETDEWEB)

    OLSON,CRAIG L.

    2000-05-17

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system.

  13. spark chamber

    CERN Multimedia

    A few cosmic rays pass through your body every second of every day, no matter where you are. Look at the spark chamber to your right – every flash is the track made by a cosmic ray from outer space. The spark chamber is filled with a special gas mixture. Cosmic rays knock electrons out of the atoms in the gas. These electrons accelerate towards high voltage metal strips layered throughout the chamber, creating sparks like little bolts of lightning.

  14. spark chamber

    CERN Multimedia

    A few cosmic rays pass through your body every second of every day, no matter where you are. Look at the spark chamber to your right – every flash is the track made by a cosmic ray from outer space. The spark chamber is filled with a special gas mixture. Cosmic rays knock electrons out of the atoms in the gas. These electrons accelerate towards high voltage metal strips layered throughout the chamber, creating sparks like little bolts of lightning.

  15. Development of the Experiment Control System and Performance Study of the Muon Chambers for the LHCb Experiment

    CERN Document Server

    Antunes Nobrega, R; Penso, G; Pinci, D

    2010-01-01

    The work of this thesis practically opened three fronts of the LHCb muon system : the development of the control and monitoring system of the readout electronics; the study of noise and threshold of the detector; and the study of the performance of the muon chambers. The LHCb muon readout apparatus is made 1368 Multi-Wire Proportional Chambers (MWPC) and 24 Gas Electron Multiplier (GEM) chambers connected to approximately 7500 16-channel front-end boards, resulting in 120000 output channels. The large-scale of this system naturally led to a complex control and monitoring system made of about 600 microcontrollers which are directly connected to the front-end electronics and handled by six computers. The development of this control system was accomplished within this thesis; the microcontroller’s firmware and the high level software, operating on the six local computers, were implemented. Besides configuring and monitoring the on-chamber readout electronics, a set of calibration and debugging oriented procedu...

  16. Application of Programmable Logic Controller (PLC) in Control System for Inner and Outer Welding Processes of Irradiation Chamber

    International Nuclear Information System (INIS)

    Inner and outer welding processes of irradiation chamber require reliable human resources so that the welding results will meet the standardized requirements for irradiation with nuclear reactor. The control system of the inner and outer welding processes of the irradiation chamber was made due to limited human resources who are able to weld the irradiation chamber perfectly. The irradiation chamber’s welding is expected to be done automatically by using the system control. The system is created by using Programmable Logic Controller (PLC) which function is to automatically organize the welding processes through the codes attached there in. The system comprises of a control unit which has been tested in a simulation, and then attached in a welding machine unit, and subsequently tested for welding the irradiation chamber. The result of the welding is also tested for its leak using bubble test. As all procedures are well followed in the welding processes, the control system is found to work properly. The welding results which are not optimum are mainly due to imperfect irradiation tubes, such as the lack of symmetry in the tube’s geometry, unclean surface, as well as the condition of the unprecise mechanical part of the tubes. (author)

  17. The control system of the multi-strip ionization chamber for the HIMM

    International Nuclear Information System (INIS)

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer–consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector

  18. Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

    International Nuclear Information System (INIS)

    In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

  19. The control system of the multi-strip ionization chamber for the HIMM

    Energy Technology Data Exchange (ETDEWEB)

    Li, Min, E-mail: limin@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yuan, Y.J. [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Mao, R.S., E-mail: Maorsh@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Xu, Z.G.; Li, Peng; Zhao, T.C.; Zhao, Z.L. [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Zhang, Nong [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2015-03-11

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer–consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  20. Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

    Energy Technology Data Exchange (ETDEWEB)

    Anghel, V.; Jewett, C.; Jonkmans, G.; Thompson, M. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Armitage, J.; Botte, J.; Boudjemline, K.; Erlandson, A.; Oakham, G. [Ottawa-Carleton Institute for Physics, Department of Physics, Carleton University, Ottawa, Ontario (Canada); Bueno, J.; Bryman, D.; Liu, Z. [Advanced Applied Physics Solutions, Vancouver, British Columbia (Canada); Charles, E.; Gallant, G. [Canada Border Services Agency, Ottawa, Ontario (Canada); Cousins, T.; Noel, S. [International Safety Research, Ottawa, Ontario (Canada); Drouin, P.-L.; Waller, D. [Defence Research and Development Canada, Ottawa, Ontario (Canada); Stocki, T. J. [Health Canada, Ottawa, Ontario (Canada)

    2011-12-13

    In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

  1. The control system of the multi-strip ionization chamber for the HIMM

    Science.gov (United States)

    Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong

    2015-03-01

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  2. Performance and operation of the ATLAS Resistive Plate Chamber system in LHC Run-1

    CERN Document Server

    Boscherini, D; The ATLAS collaboration

    2014-01-01

    The barrel region of the ATLAS muon spectrometer is instrumented with a Resistive Plate Chamber (RPC) system covering the pseudo-rapidity range |η|<1.05 with a detector surface of almost 4000 m2. The RPCs, providing the first level trigger signal and the track coordinate in the non-bending plane for the candidate muons, have played a fundamental role in the physics studies carried out by ATLAS, culminated with the discovery of the Higgs boson. During the LHC Run-1 the RPC have shown excellent performances up to the maximum instantaneous luminosity of 0.7 × 1034 cm−2 s−1, corresponding approximately to 70% of the design value. The detector operation in the challenging background and pileup conditions of the LHC environment will be presented together with the problems encountered and their corresponding solutions. The plans for the maintenance and consolidation of the ATLAS RPC system during the current LHC shutdown, in view of the increased luminosity expected in Run-2, will be also presented.

  3. Transdifferentiation of human amniotic epithelial cells into acinar cells using a double-chamber system.

    Science.gov (United States)

    Huang, Gui-Lin; Zhang, Ni-Ni; Wang, Jun-Sheng; Yao, Li; Zhao, Yu-Jie; Wang, Yu-Ying

    2012-08-01

    This study investigated the transdifferentiation of stem cells from human amnion tissue into functional acinar cells (ACs) using a co-culture system. Human amniotic epithelial cells (hAECs) were isolated from amnion tissue by mechanical mincing and enzymatic digestion. After primary culture, the phenotype of the cells was identified by flow cytometry (FCM) and immunocytochemical staining. hAECs were co-cultured with submandibular gland acinar cells of SD rats using a double-chamber system. The expression of α-amylase was determined by immunocytochemical method and fluorescent real-time quantitative reverse transcription polymerase chain reaction (RT-PCR) after induction for 1 and 2 weeks, respectively. Digestion with trypsin is an effective method for isolating hAECs from amnion tissue. These cells were positive for CD29 and CK19 and weakly positive for CD44 and α-amylase. Within 2 weeks, α-amylase in hAECs increased with induction time. The expression of α-amylase in hAECs was increased 3.38-fold after co-culturing for 1 week. This ratio increased to 6.6-fold, and these cells were positive for mucins, after co-culturing for 2 weeks. hAECs possess the potential to differentiate into ACs in vitro. They might be a stem cell resource for clinical applications of cell replacement therapy in salivary gland dysfunction diseases. PMID:22800093

  4. Limitations to soybean photosynthesis at elevated carbon dioxide in free-air enrichment and open top chamber systems

    Science.gov (United States)

    It has been suggested that the stimulation of soybean photosynthesis by elevated carbon dioxide concentration was less in free-air carbon dioxide enrichment (FACE) systems than in open top chambers (OTC). However, this has not been tested using the same cultivars grown in the same location. We tes...

  5. Quantitative assessment of mitral and aortic insufficiency from effective systemic ejection fraction measured by radiocardiography and cardiac chambers scanning

    International Nuclear Information System (INIS)

    Comparison between the effective systemic ejection fraction defined by radiocardiography and cardiac chambers scanning, and the whole left ventricular ejection fraction calculated by cineangiocardiography allows an accurate assessment of mitral and aortic regurgitation extent. In case of both mitral and aortic insufficiency, each regurgitation can be quantitatively dissociated by means of the aortic isotopic dilution curve recorded at the same time as the radiocardiogram

  6. Tritium measurement and monitoring in experimental and process systems with ionization chambers

    International Nuclear Information System (INIS)

    Historically, ionization chambers have been used successfully to measure low-level tritium concentrations in air for radiation protection purposes. Problems have been encountered in applying this technique to measure much higher concentrations of tritium in gases other than air, particularly to measure tritium in argon and helium. An experimental program was initiated to investigate the various factors that affect the response of ionization chambers. Carrier gas effects on the measurement of elemental tritium were investigated in the concentration range 0-150 Ci/m3. Higher than theoretical calibration factors were obtained consistently with low-level tritium gas standards in both helium and argon, while with high-level gas standards the experimental calibration factors were close to the theoretical value. Use of a commercial ionization chamber to measure tritiated water vapour in dry air streams resulted in severe contamination of the chamber. Water swamping of the dry air stream reduced the ionization chamber contamination to a negligible level, allowing reliable measurements to be made. The calibration of ionization chambers with representative process gases and operating conditions is necessary to ensure reliable tritium concentration measurements. (Author) (15 refs., 7 figs., 3 tabs.)

  7. Development of imaging microstrip gas chamber and high speed data acquisition system

    International Nuclear Information System (INIS)

    The MicroStrip Gas Chamber (MSGC) was proposed in 1988 as a new type of proportional gaseous detector providing an excellent position resolution. We developed MSGC as a new generation tracking detector which has two-dimensional readout. As well known, MSGC is expected to work stably in high intensity X-rays of ∼107 counts/mm2, and a position resolution is achieved ∼30 μm. Our research and development of MSGC is being carried out in order to use it as a real-time X-ray imaging detector in the SPring-8 synchrotron radiation facility in Japan. This MSGC had been realized using Multi Chip Module (MCM) Technology which is one of the LSI processing techniques. Anodes and cathodes of the MSGC are made on 20 μm thick polyimide substrate, and back strips are arranged orthogonally behind the substrate. The signal induced on each strip is read independently, and a two-dimensional position of the incident particle was derived from both electrodes. Clear X-ray images were successfully obtained from this MSGC. The recent progress on our MSGC is reported in Ref. We are also developing a novel high speed readout system based on the CPLD's (Complex Programmable Logic Devices) module in order to read data from MSGC at high counting rate conditions. This new MSGC will be used for dynamic X-ray imaging (scattering or/and absorption) experiment with synchrotron radiation facility. (author)

  8. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    International Nuclear Information System (INIS)

    A new e+e- linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  9. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Diener, R.

    2006-12-15

    A new e{sup +}e{sup -} linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  10. A QA/QC system to monitor the planarity of the tube layers in MDT chambers construction

    CERN Document Server

    Ciapetti, G; Giacalone, R; Montani, L; Pinci, D

    1998-01-01

    In this note a commercial laser system for the monitoring of the correct placement of the MDT drift tube end-plugs on the assembly combs is described. The results of various tests are presented; the sensitivity of the system is well matched to the required mechanical accuracy in the MDT chambers construction. We propose this method for QA/QC during tube layers assembly.

  11. Closed chamber globe stabilization and needle capsulorhexis using irrigation hand piece of bimanual irrigation and aspiration system

    Directory of Open Access Journals (Sweden)

    Rai Harminder K

    2005-08-01

    Full Text Available Abstract Background The prerequisites for a good capsulorhexis include a deep, well maintained anterior chamber, globe stabilization and globe manipulation. This helps to achieve a capsulorhexis of optimal size, shape and obtain the best possible position for a red glow under retroillumination. We report the use of irrigation handpiece of bimanual irrigation aspiration system to stabilize the globe, maintain a deep anterior chamber and manipulate the globe to a position of optimal red reflex during needle capsulorhexis in phacoemulsification. Methods Two side ports are made with 20 G MVR 'V' lance knife (Alcon, USA. The irrigation handpiece with irrigation on is introduced into the anterior chamber through one side port and the 26-G cystitome (made from 26-G needle is introduced through the other. The capsolurhexis is completed with the needle. Results Needle capsulorhexis with this technique was used in 30 cases of uncomplicated immature senile cataracts. 10 cases were done under peribulbar anaesthesia and 20 under topical anaesthesia. A complete capsulorhexis was achieved in all cases. Conclusion The irrigating handpiece maintains deep anterior chamber, stabilizes the globe, facilitates pupillary dilatation, and helps in maintaining the eye in the position with optimal red reflex during needle capsulorhexis. This technique is a safe and effective way to perform needle capsulorhexis.

  12. Dual chamber shape memory alloy unplugging and mixing system coupled to a high pressure optical cell for biophysical studies

    International Nuclear Information System (INIS)

    High pressure optical measurements are useful for understanding structure and function of biological molecules. Commonly used high-pressure optical cells can only observe a single sample under elevated pressure. If researchers wish to observe the interaction between different biological samples, they must mix the samples at atmospheric pressure, place the mixture within the pressure chamber, and wait until the desired pressure is reached. In many cases, researchers want to observe the initial reaction between two separate biological samples; however, the sample mixing and the assembly of the high pressure optical cell coupled with a spectrometer at desired pressures can take several minutes or longer. Our current design uses a shape memory alloy (SMA) spring actuator to seal a dual chamber cuvette for separation of two different biological samples. Once the desired pressure is reached, power is applied to the system that activates the SMA to unplug and mix the two samples using a micro dc-motor. During the mixing efficiency tests, deionized water was placed in the top chamber of the cuvette and an aqueous solution of carboxyfluorescein (a fluorescent dye) placed in the bottom chamber. Based on this design, we were able to achieve a total unplugging and mixing time within a few seconds (at atmospheric pressure). Quicker mixing means researchers will have more reliable data for analyzing the initial reactions between two different biological samples. Future tests on this new actuator will be conducted at elevated pressures. (paper)

  13. Vacuum chamber

    International Nuclear Information System (INIS)

    A detailed description is given of the vacuum chamber of the so-called experimental equipment DEMAS (double-arm-time-of-flight spectrometer) at the heavy ion accelerator U-400 at the JINR-Dubna. (author)

  14. A fibre-optic UV system for H(2)SO(4) production in aerosol chambers causing minimal thermal effects

    CERN Document Server

    Kupc, A; Onnela, A; Duplissy, J; Mathot, S; Danielczok, A; Walther, H; Minginette, P; Rondo, L; Ickes, L; Curtius, J; Wagner, P E; Amorim, A; Lima, J M; Ehrhart, S; Kurten, A

    2011-01-01

    A novel fibre-optic UV illumination system for sulphuric acid (H(2)SO(4)) production has been developed. The illumination system described in this paper provides sufficient ultraviolet light (UV) power while causing practically no thermal effect on the aerosol chamber (temperature variation <0.005 degrees C at full UV illumination). A similar thermal stability has not been achieved in other comparable experimental set-ups so far. The spectrum provided by the fibre-optic UV system corresponds to the UVB region, illuminates the chamber in a reasonably uniform way and is comparable to the ground level actinic flux. The UV system has been installed for the Cosmics Leaving OUtdoor Droplets (CLOUD) chamber experiments at CERN. Precise, easily-adjustable and reproducible concentrations of H(2)SO(4) were generated by adjusting the UV light intensity. This paper gives an overview on the design of this new system as well as insights on its performance and application. (C) 2011 Elsevier Ltd. All rights reserved.

  15. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  16. Toxic Test Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description/History: Hazardous material test facility Both facilities have 16,000 cubic foot chambers, equipped with 5000 CFM CBR filter systems with an air change...

  17. Design and implementation of a three axis digitally controlled traverse system for flow surveys in a drying chamber

    OpenAIRE

    Achilleas Bardakas; Vasilis Chasiotis; Dimitrios Tzempelikos; Andronikos Filios

    2014-01-01

    The current paper describes the design and development of a pc-controlled three axis traverse system that aims to serve extensive velocity and temperature measurements into the drying chamber of a laboratory scale convective dryer. The traversing gear design has been conducted based on the convective dryer’s specific experimental requirements and limitations. The fabricated traversing gear uses a trapezoidal lead screw-nut assembly supported by linear ball bearings, coupled with bipolar stepp...

  18. Dual chamber system providing simultaneous etch and deposition on opposing substrate sides for growing low defect density epitaxial layers

    Science.gov (United States)

    Kulkarni, Nagraj S.; Kasica, Richard J. ,

    2011-03-08

    A dual-chamber reactor can include a housing enclosing a volume having a divider therein, where the divider defines a first chamber and a second chamber. The divider can include a substrate holder that supports at least one substrate and exposes a first side of the substrate to the first chamber and a second side of the substrate to the second chamber. The first chamber can include an inlet for delivering at least one reagent to the first chamber for forming a film on the first side of the substrate, and the second chamber can include a removal device for removing material from the second side of the substrate.

  19. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    International Nuclear Information System (INIS)

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The present thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold,HV) was investigated quantitatively. Also detailed studies on single cells, qualified as ''dead'' and ''noisy'' were done. For the DAQ tests a flexible hardware and software environment was needed. The organization and installation of the supplied electronics, as well as the software development was realized within the scope of this thesis. The DCS tests were focused on the local gas pressure read-out components, attached directly to the chamber: pressure sensor, manifolds and the pressure ADC (PADC). At first it was crucial to proof, that the calibration of the mentioned chamber components for the gas pressure measurement is valid. The sensor calibration data were checked and possible differences in their response to the same pressure were studied. The analysis of the results indicated that the sensor output depends also on the ambient temperature, a new experience which implied an additional pedestal measurement of the chamber gas pressure sensors at CMS. The second test sequence

  20. CYTOKINES IN ANTERIOR EYE CHAMBER LIQUID: THEIR ROLE IN DEVELOPMENT OF SYSTEMIC IMMUNE RESPONSE TO OCULAR TISSUE ANTIGENS

    Directory of Open Access Journals (Sweden)

    I. G. Kulikova

    2015-04-01

    Full Text Available The work is dedicated to studies of interrelations between the cytokine contents in the liquid from anterior eye chamber (AEC, and development of systemic immune response to ocular tissue antigens, described in terms of an anterior eye chamber-associated immune disturbance (ACAID phenomenon. The immune assays were conducted in parallel, using multiplex cytokine analysis (flow cytometry technique, and leukocyte inhibition migration reaction. Twenty-six patients with different forms of ophthalmic pathology were examined, including cases of uveitis (18, keratouveitis (3, glaucoma (5. It is shown that the reduced TGF-β1 levels and increased concentrations of proinflammatory, chemotactic cytokines in AEC liquid are associated with development of organ-specific immune sensitization. 

  1. Opposed port alignment system (OPAS): a commercial astronomical telescope modified for viewing the interior of the NIF target chamber

    Science.gov (United States)

    Manuel, Anastacia M.; McCarville, Tom J.; Seppala, Lynn G.; Klingmann, Jeff L.; Kalantar, Daniel H.

    2012-10-01

    The National Ignition Facility (NIF) requires high resolution live images of regions inside the target chamber in order to align diagnostic instruments to fusion targets and to monitor target stability. To view the interior of the target chamber, we modified a commercial 11-inch Schmidt-Cassegrain telescope to develop the Opposed Port Alignment System (OPAS). There are two OPAS systems installed on the target chamber ports directly opposite the diagnostics. This paper describes the optical design, highlighting the two key modifications of the telescope. The first key modification was to reposition the Schmidt corrector plate and to uniquely mount the secondary mirror to a precision translation stage to adjust focus from 5.5 m to infinity. The stage is carefully aligned to ensure that the telescope's optical axis lies on a straight line during focus adjustments. The second key modification was a custom three element lens that flattens the field, corrects residual aberrations of the Schmidt-Cassegrain and, with a commercial 1:1 relay lens, projects the final image plane onto a large format 50 mega-pixel camera. The OPAS modifications greatly extend the Schmidt-Cassegrain telescope's field of view, producing nearly diffraction-limited images over a flat field covering +/-0.4 degrees. Also discussed in the paper are the alignment procedure and the hardware layout of the telescope.

  2. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Automated system with LabVIEW for the obtention of voltage plateau, graphic of sensitivity and operation voltage in an ionization chamber

    International Nuclear Information System (INIS)

    The work developed for the Laguna Verde Nuclear Power Central allows to obtain the voltage plateau, graphic of sensitivity and operation voltage of three types of ionization chambers which are used in their monitoring systems of process radiation. The automated system is based in a personal computer (Pc) for controlling and acquiring data from the different instruments used, its programming was realized with virtual instruments (LabVIEW, National Instruments software). The system also realizes a diagnosis of the ionization chamber and determine whether the parameters obtained are inside of the manufacturer specifications, that is to say, it determines when the ionization chamber must be replaced. (Author)

  4. ESM Calculations for Hydroponic Plant and Fungi Growth Chambers, Biosolids Dewatering Plant System, and Tilapia Growth System--EAC Presentation 2004

    OpenAIRE

    Aydogan, Selen; Blau, Gary; Pekny, Joseph; Reklaitis, Gintaras

    2004-01-01

    In this work, preliminary Equivalent System Mass (ESM) estimations of the Hydroponic Plant and Fungi Growth Chambers, Biosolids Dewatering Plant and Tilapia Growth Systems are presented. ESM may be used to evaluate a system or technology based on its mass, volume, power, cooling and manpower requirements. This ESM analysis focuses on a hypothetical device, instead of the anticipated technology that is system flight proven in mission operations. We have examined the Evolved Mars Base mission, ...

  5. Robert Chambers

    NARCIS (Netherlands)

    K. Biekart (Kees); D.R. Gasper (Des)

    2013-01-01

    textabstractProfessor Robert Chambers is a Research Associate at the Institute of Development Studies (IDS), University of Sussex (Brighton, UK), where he has been based for the last 40 years, including as Professorial Research Fellow. He became involved in the field of development management in the

  6. Whole System Carbon Exchange of Small Stands of Pinus Ponderosa Growing at Different CO(sub 2) concentrations in open top chambers; FINAL

    International Nuclear Information System (INIS)

    Functional understanding of the carbon cycle from the molecular to the global level is a high scientific priority requiring explanation of the relationship between fluxes at different spatial and temporal scales. We describe methods used to convert an open top chamber into both closed and open flow gas exchange systems utilized to measure such fluxes. The systems described consist of temporary modifications to an open top chamber, and are put in place for several days on one or several open top chambers. In the closed system approach, a chamber is quickly sealed for a short, predetermined time interval, the change in gas concentrations is measured, then the chamber is unsealed and ventilated. In the open flow system approach, airflow into the open top chamber is measured by trace gas injection, and the air stream concentration of CO(sub 2) and water vapor is measured before and after injection into the chamber. The closed chamber approach can resolve smaller fluxes, but causes transient increases in chamber air temperature, and has a high labor requirement. The open flow approach reduces the deviation of measuring conditions from ambient, may be semi-automated (requiring less labor), allows a more frequent sampling interval, but cannot resolve low fluxes well. Data demonstrating the capabilities of these systems show that, in open canopies of ponderosa pine, scaling fluxes from leaves to whole canopies is well approximated from summation of leaf P(sub s) rates. Flux measurements obtained from these systems can be a valuable contribution to our understanding whole system material fluxes, and challenge our understanding of ecosystem carbon budgets

  7. Designing Single Chamber Hwcvd System for High Deposition Rate Device Quality A-Si:h Thin Films and Solar Cells

    Directory of Open Access Journals (Sweden)

    N.A. Wadibhasme

    2011-01-01

    Full Text Available A new single chamber HWCVD with vertically mounted substrates and filaments has been designed for depositing device quality a-Si:H films with high deposition rate. Optimization studies on films deposited in this chamber under a variety of deposition conditions yielded uniform films at more than 7Å/sec deposition rate and with very low oxygen content. These films show a photoconductivity gain of more than 105. The working pressure has been kept quite low at 15 mtorr compared to earlier studies. i-layers of a p-i-n single junction solar cells were deposited on the TCO (Asahi-U type glass in this reactor. The initial p-layer and the final n-layer were deposited in another system with separate chambers for these doped layers thus exposing the p-layer as well as the i-layer to the atmosphere during the transfer. Using this optimized intrinsic layer, a-Si:H based p-i-n solar cell showed a conversion efficiency of 4.7 %.

  8. Dual-Chamber Pacing for Cardiac Arrhythmias: Controversies in Cloning the Conduction System

    OpenAIRE

    Parsonnet, Victor; Bernstein, Alan D.; Norman, John C.

    1984-01-01

    From the outset, the art and science of cardiac pacing has been beset with a variety of problems. With the passage of time and concentrated effort in the interrelated sciences, many have been solved. We no longer are concerned with premature battery failure or leaking pulse-generator capsules, but now focus on an entirely new set of issues that beg for resolution. Foremost among these is the true role of dual-chamber pacing in the treatment of slow and fast cardiac arrhythmias of a multitude ...

  9. A new wire chamber front-end system, based on the ASD-8 B chip

    CERN Document Server

    Kruesemann, B A M; Ellinghaus, F; Frekers, D; Hagemann, M; Hannen, V M; Heynitz, H V; Heyse, J; Rakers, S; Sohlbach, H; Wörtche, H J

    1999-01-01

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  10. Automated Electrostatics Environmental Chamber

    Science.gov (United States)

    Calle, Carlos; Lewis, Dean C.; Buchanan, Randy K.; Buchanan, Aubri

    2005-01-01

    The Mars Electrostatics Chamber (MEC) is an environmental chamber designed primarily to create atmospheric conditions like those at the surface of Mars to support experiments on electrostatic effects in the Martian environment. The chamber is equipped with a vacuum system, a cryogenic cooling system, an atmospheric-gas replenishing and analysis system, and a computerized control system that can be programmed by the user and that provides both automation and options for manual control. The control system can be set to maintain steady Mars-like conditions or to impose temperature and pressure variations of a Mars diurnal cycle at any given season and latitude. In addition, the MEC can be used in other areas of research because it can create steady or varying atmospheric conditions anywhere within the wide temperature, pressure, and composition ranges between the extremes of Mars-like and Earth-like conditions.

  11. Development of a burner system / combustion chamber system for a light heating oil operated micro gas turbine; Entwicklung eines Brenner-/ Brennkammersystems fuer eine mit Heizoel EL betriebene Mikrogasturbine

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, I.; Scherer, V. [Ruhr-Universitaet Bochum (Germany). Lehrstuhl fuer Energieanlagen- und Energieprozesstechnik

    2009-07-01

    The authors of the contribution under consideration report on a design and experimental investigation of a micro gas turbine consisting combustion chamber for light fuel oil. The times of self-ignition and the flame velocities under the operating conditions of micro gas turbines are the starting point. The geometry of the premix-burners was designed by means of numeric flow simulations. Subsequently, an allocation of air in the combustion chamber system, necessary for lean premixed combustion, was adjusted by geometrical optimization (computations of the pressure loss). Measurements of pollutants of the combustion chamber test stand resulted in a stable and low-pollution combustion (NO{sub x} < 30 ppm, CO < 20 ppm) over a large area of load.

  12. Ionization chamber intended to use in a system of a valuation of patient exposition on ionizing radiation during X-ray diagnostic examinations

    International Nuclear Information System (INIS)

    The construction of the air ionization chamber intended to use in a system of a valuation of patient exposition on ionizing radiation during X-ray diagnostic examinations is described. A collaboration system with X-ray limiter is discussed and a measuring method is presented. The results of testing a model of the chamber obtained in conditions of its collaboration with the X-ray limiter and X-ray generator are presented and discussed. An analysis of the experimental results is made. In a recapitulation the different possibilities of a wide application of the chamber are presented. (author)

  13. Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

    Science.gov (United States)

    Kubalak, David; Hadjimichael, Theodore; Ohl, Raymond; Slotwinski, Anthony; Telfer, Randal; Hayden, Joseph

    2012-01-01

    Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a

  14. A pressurized ion chamber monitoring system for environmental radiation measurements utilizing a wide-range temperature-compensated electrometer

    International Nuclear Information System (INIS)

    The performance of a complete pressurized ion chamber (PIC) radiation monitoring system is described. The design incorporates an improved temperature-compensated electrometer which is stable to ±3 · 10-16 A over the environmental range of temperature (-40 to +40 C). Using a single 1011 Ω feed-back resistor, the electrometer accurately measures currents over a range from 3 · 10-15 A to 3 · 10-11 A. While retaining the sensitivity of the original PIC system (the instrument responds readily to small background fluctuations on the order of 0.1 μR h-1), the new system measures radiation levels up to the point where the collection efficiency of the ion chamber begins to drop off, typically ∼27 pA at 1 mR h-1. A data recorder and system controller was designed using the Tattletale trademark Model 4A computer. Digital data is stored on removable solid-state, credit-card style memory cards

  15. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    Directory of Open Access Journals (Sweden)

    Pengyu Zhu

    2016-03-01

    Full Text Available Digital polymerase chain reaction (PCR has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ, sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO genome samples using commercial digital PCR detection systems.

  16. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    Science.gov (United States)

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems. PMID:26999129

  17. Numerical analysis on the effect of swirl ratios on swirl chamber combustion system of DI diesel engines

    International Nuclear Information System (INIS)

    Highlights: • A new swirl chamber combustion system of DI diesel engines is proposed. • The appropriate vortex motion can reduce the wall concentration of mixture. • It has best emissions at swirl ratio of 0.8. • Before spray, the turbulent kinetic energy is primarily controlled by the squish. • After spray, the combustion swirl and reverse squish have a great impact on TKE. - Abstract: In order to improve the spray spatial distribution and promote the mixture quality, enhancing airflow movement in a combustion chamber, a new swirl chamber combustion system in direct injection (DI) diesel engines is proposed. The mixture formation and combustion progress in the cylinder are simulated and investigated at several different swirl ratios by using the AVL-FIRE code. The results show that in view of the fuel/air equivalence ratio distribution, the uniformity of mixture with swirl ratio of 0.2 is better. Before spray injection, the turbulent kinetic energy distribution is primarily controlled by the squish. After spray, the combustion swirl and reverse squish swirl have an effect on temperature distribution and turbulent kinetic energy (TKE) in the cylinder. The NO mass fraction is the lowest at swirl ratio of 0.8 and the highest at swirl ratio of 2.7, while Soot mass fraction is the lowest at swirl ratio of 0.2 and the highest at swirl ratio of 3.2. The appropriate swirl is benefit to improve combustion. To sum up, the emissions at swirl ratio of 0.8 has a better performance in the new combustion system

  18. Calibration of a 4π-γ well-type ionization chamber system for measuring of the radionuclides activity

    International Nuclear Information System (INIS)

    The calibration of a 4π well-type ionization Chamber System installed at the Laboratorio de Metrologia Nuclear, of the Instituto de Energia Atomica of Sao Paulo used for of the activity determination of radioactive solutions is descrided. The determination can be performed by two methods: 1) Direct Method, comparing the ionization Chamber response for solutions of unknown activity against that obtained with a solution which is standardized by the Absolute 4πβγ Coincidence Method. By this method the following radionuclides are standardized: 241Am, 139Ce, 198Au, 22Na, 134Cs, 54Mn, 60Co, 42K, 24Na. In this case, the accuracy achieved is about 0.2 to 0,4%. 2) Indirect Method, by means of curves of relative beta or gama efficiency, which were determined in this work. This method can be applied for those radionuclides not included in the direct method. In this case, the accuracy depends on the gama energy range of the curves and on the accuracy of the absolute gama intensities, taken from the literature. In general the uncertainty is greater than the direct method, but values of 0,2% can be achieved in favourable cases. The upper and lower limits of Activity that can be measured depend on the radionuclide. These limits are from a few micro-curies to many mili-curies, which are satisfactory for most purposes. The sample preparation is simple and the time spent in the measurement is, in general, restricted to a few minutes. These are some of the advantages of this ionization Chamber System in comparison with other systems

  19. Ionization chamber

    International Nuclear Information System (INIS)

    An ionization chamber X-ray detector is described. It comprises a flat cathode sheet parallel to an anode which has a perforated insulating layer on its surface. An open grid, a thin perforated metal sheet is disposed on the insulating layer - the perforations of the layer and sheet are aligned. There is a detector gas and means for maintaining the grid at an electric potential between that of the anode and cathode and for measuring the current flow from the anode to the cathode. The grid shields the anode from the electric field produced by the positive ions which flow towards the cathode and this permits an independent measurement of the electron current flowing to the anode; even when the X-ray pulse length is not much shorter than the ion drift time. The recovery time of the ionization chamber is thus decreased by several orders of magnitude over previous chambers. The grid will normally be fixed to the anode and by shielding the anode from the cathode electric field, tends to eliminate capacitive microphone currents which would otherwise flow in the anode circuit. (U.K.)

  20. Storage unite for the TV image lithokon storing in television monitoring system for the RISK spectrometer streamer chamber

    International Nuclear Information System (INIS)

    Described is the TV image storage unit (TVISU) based on a single-beam lithokon with a silicon target. TVISU is a part of television monitoring system of the RISK spectrometer streamer chamber. A single-inch lithokon with the writing rate of 0.25 km/s, resolution of 750 television lines per a target diameter and read-out time up to 15 min, has been used in TVISU. The description of the lithokon is presented along with the TVISU block diagram. TVISU operates together with TV cameras of chalnicon tubes ointed with electrostatic electron optical converters

  1. Numerical investigations of cooling holes system role in the protection of the walls of a gas turbine combustion chamber

    Energy Technology Data Exchange (ETDEWEB)

    Ben Sik Ali, Ahlem; Kriaa, Wassim; Mhiri, Hatem [Ecole Nationale D' Ingenieurs de Monastir, Unite de Thermique et Thermodynamique des Procedes industriels, Monastir (Tunisia); Bournot, Philippe [IUSTI, UMR CNRS 6595, Marseille (France)

    2012-05-15

    Numerical simulations in a gas turbine Swirl stabilized combustor were conducted to investigate the effectiveness of a cooling system in the protection of combustor walls. The studied combustion chamber has a high degree of geometrical complexity related to the injection system as well as the cooling system based on a big distribution of small holes (about 3,390 holes) bored on the flame tube walls. Two cases were considered respectively the flame tube without and with its cooling system. The calculations were carried out using the industrial CFD code FLUENT 6.2. The various simulations made it possible to highlight the role of cooling holes in the protection of the flame tube walls against the high temperatures of the combustion products. In fact, the comparison between the results of the two studied cases demonstrated that the walls temperature can be reduced by about 800 C by the mean of cooling holes technique. (orig.)

  2. The air supply hole of the inlet chamber and preventing the inflow of harmful impurities into the ventilation system

    Directory of Open Access Journals (Sweden)

    N.A. Litvinova

    2015-10-01

    Full Text Available The article discusses the dependences of carbon monoxide (II concentrations on the height of the building façade based on the results of in situ tests with the goal of preventing the inflow of pollutants into the ventilation system. Carbon oxide (II may enter the premises when the inlet ventilation system is working through the inlet chamber from external sources of emission. i.e. vehicles and low and medium-power boilers in the urban environment. We have constructed nomograms to adjust the height of the receiving hole for air intake by the ventilation system depending on the quality of the outdoor air on the height of buildings from external sources of different heights in relation to the building. We have suggested guidelines allowing to design ventilation systems depending on the quality of outdoor air over the entire height of the building, which cannot be done at the design stage.

  3. Design, construction and test of performance of a system to measure a magnetic field in a vacuum chamber

    International Nuclear Information System (INIS)

    An in-vacuum undulator (IU) with a small period length can enhance the photon brilliance at hard x-ray region in a medium-energy facility; a cryogenic permanent-magnet undulator (CU) can provide greater photon energy about 65 keV. Insertion device (ID) of these two kinds are key technologies of the 3-GeV Taiwan Photon Source (TPS), but a conventional system with a granite bench to measure the magnetic field is unable to test the magnetic performance after the magnetic array is assembled inside the vacuum chamber. To measure the magnetic performance of these IDs before installation in the storage ring, we constructed a system to measure the magnetic field in a vacuum chamber, based on laser-positioning components and dynamic adjustment of positions of the Hall sensor. To ensure great accuracy of the position of a hall sensor, we corrected the vertical and transverse positions during measurements. A test magnetic array was measured six times under the same conditions to verify the reproducibility of the measurements; the results show that this system is reliable to test the distribution of the field in an undulator. We describe details of our design and measurements in this article.

  4. An improvement study on the closed chamber distillation system for recovery of renewable salts from salt wastes containing radioactive rare earth compounds

    International Nuclear Information System (INIS)

    In this paper, an improvement study on the closed chamber distillation system for recovery of renewable salts from salt wastes containing radioactive rare earth compounds was performed to determine optimum operating conditions. It was very important to maintain the pressure in the distillation chamber below 10 Torr for a high efficiency (salt recovery >99 %) of the salt distillation. This required increasing the salt vaporization and condensation rates in the distillation system. It was confirmed that vaporization and condensation rates could be improved controlling the given temperature of top of the condensation chamber. In the distillation tests of the salt wastes containing rare earth compounds, the operation time at a given temperature was greatly reduced changing the given temperature of top of the condensation chamber from 780 to 700 deg C. (author)

  5. Design and implementation of a three axis digitally controlled traverse system for flow surveys in a drying chamber

    Directory of Open Access Journals (Sweden)

    Achilleas Bardakas

    2014-06-01

    Full Text Available The current paper describes the design and development of a pc-controlled three axis traverse system that aims to serve extensive velocity and temperature measurements into the drying chamber of a laboratory scale convective dryer. The traversing gear design has been conducted based on the convective dryer’s specific experimental requirements and limitations. The fabricated traversing gear uses a trapezoidal lead screw-nut assembly supported by linear ball bearings, coupled with bipolar stepper motors for positioning in three dimensional spaces. A custom drive system solution was selected for achieving accurate motor control, paired with computer software developed using the LabVIEW® graphical programming environment. The functionality of the traversing system was experimentally verified by testing mechanical and electronic assemblies, but also by determining the per axis positioning error. Keywords: Fluid Flow Measurement, Digital Control, Motion Control, Displacement Control, Electromechanical Devices.

  6. Measurements of CO2 exchange with an automated chamber system throughout the year: challenges in measuring nighttime respiration on porous peat soil

    Directory of Open Access Journals (Sweden)

    M. Koskinen

    2013-08-01

    Full Text Available We built an automatic chamber system to measure greehouse gas (GHG exchange in forested peatland ecosystems. We aimed to build a system robust enough which would work throughout the year and could measure through a changing snowpackin addition to producing annual GHG fluxes by integrating the measurements without the need of using models. The system worked rather well throughout the year, but it was not service free. Gap filling of data was still necessary. We observed problems in carbon dioxide (CO2 flux estimation during calm summer nights, when a CO2 concentration gradient from soil/moss system to atmosphere builds up. Chambers greatly overestimated the nighttime respiration. This was due to the disturbance caused by the chamber to the soil-moss CO2 gradient and consequent initial pulse of CO2 to the chamber headspace. We tested different flux calculation and measurement methods to solve this problem. The estimated flux was strongly dependent on (1 the type of the fit (linear and polynomial, (2 the starting point of the fit after closing the chamber, (3 the length of the fit, (4 the speed of the fan mixing the air inside the chamber, and (5 atmospheric turbulence (friction velocity, u*. The best fitting method (the most robust, least random variation was linear fitting with the period of 120–240 s after chamber closure. Furthermore, the fan should be adjusted to spin at minimum speed to avoid the pulse-effect, but it should be kept on to ensure mixing. If nighttime problems cannot be solved, emissions can be estimated using daytime data from opaque chambers.

  7. Measurements of CO2 exchange with an automated chamber system throughout the year: challenges in measuring night-time respiration on porous peat soil

    Directory of Open Access Journals (Sweden)

    M. Koskinen

    2014-01-01

    Full Text Available We built an automatic chamber system to measure greenhouse gas (GHG exchange in forested peatland ecosystems. We aimed to build a system robust enough which would work throughout the year and could measure through a changing snowpack in addition to producing annual GHG fluxes by integrating the measurements without the need of using models. The system worked rather well throughout the year, but it was not service free. Gap filling of data was still necessary. We observed problems in carbon dioxide (CO2 respiration flux estimation during calm summer nights, when a CO2 concentration gradient from soil/moss system to atmosphere builds up. Chambers greatly overestimated the night-time respiration. This was due to the disturbance caused by the chamber to the soil-moss CO2 gradient and consequent initial pulse of CO2 to the chamber headspace. We tested different flux calculation and measurement methods to solve this problem. The estimated flux was strongly dependent on (1 the starting point of the fit after closing the chamber, (2 the length of the fit, (3 the type of the fit (linear and polynomial, (4 the speed of the fan mixing the air inside the chamber, and (5 atmospheric turbulence (friction velocity, u*. The best fitting method (the most robust, least random variation for respiration measurements on our sites was linear fitting with the period of 120–240 s after chamber closure. Furthermore, the fan should be adjusted to spin at minimum speed to avoid the pulse-effect, but it should be kept on to ensure mixing. If night-time problems cannot be solved, emissions can be estimated using daytime data from opaque chambers.

  8. Target Chamber Manipulator

    Science.gov (United States)

    Tantillo, Anthony; Watson, Matthew

    2015-11-01

    A system has been developed to allow remote actuation of sensors in a high vacuum target chamber used with a particle accelerator. Typically, sensors of various types are placed into the target chamber at specific radial and angular positions relative to the beam line and target. The chamber is then evacuated and the experiments are performed for those sensor positions. Then, the chamber is opened, the sensors are repositioned to new angles or radii, and the process is repeated, with a separate pump-down cycle for each set of sensor positions. The new sensor positioning system allows scientists to pre-set the radii of up to a dozen sensors, and then remotely actuate their angular positions without breaking the vacuum of the target chamber. This reduces the time required to reposition sensors from 6 hours to 1 minute. The sensors are placed into one of two tracks that are separately actuated using vacuum-grade stepping motors. The positions of the sensors are verified using absolute optical rotary encoders, and the positions are accurate to 0.5 degrees. The positions of the sensors are electronically recorded and time-stamped after every change. User control is through a GUI using LabVIEW.

  9. Gridded ionization chamber and dual parameter measurement system for fast neutron-induced charged particles emission reaction

    International Nuclear Information System (INIS)

    A twin ionization chamber with a common cathode and grids is described for (n,α), (n,p) studies. The chamber is used to determine the energy spectra and angular distribution of the charged particles emitted from the sample positioned on the cathode by dual parameter measurements of coinciding pulses from the anode and cathode of the ionization chamber. Pu α source is used to test the property of the chamber, an isotropic angular distribution is basically showed and the energy resolution is about 2%. This ionization chamber has already been applied to the studies of the 40Ca(n,α) and 64Zn(n,α) reactions

  10. Micromorph tandem solar cells: optimization of the microcrystalline silicon bottom cell in a single chamber system

    Institute of Scientific and Technical Information of China (English)

    Zhang Xiao-Dan; Zheng Xin-Xia; Xu Sheng-Zhi; Lin Quan; Wei Chang-Chun; Sun Jian; Geng Xin-Hua; Zhao Ying

    2011-01-01

    We report on the development of single chamber deposition of microcrystalline and micromorph tandem solar cells directly onto low-cost glass substrates.The cells have pin single-junction or pin/pin double-junction structures on glass substrates coated with a transparent conductive oxide layer such as SnO2 or ZnO.By controlling boron and phosphorus contaminations,a single-junction microcrystalline silicon cell with a conversion efficiency of 7.47% is achieved with an i-layer thickness of 1.2 μm.In tandem devices,by thickness optimization of the microcrystalline silicon bottom solar cell,we obtained an initial conversion efficiency of 9.91% with an aluminum (Al) back reflector without a dielectric layer.In order to enhance the performance of the tandem solar cells,an improved light trapping structure with a ZnO/Al back reflector is used.As a result,a tandem solar cell with 11.04% of initial conversion efficiency has been obtained.

  11. Micromorph tandem solar cells: optimization of the microcrystalline silicon bottom cell in a single chamber system

    Science.gov (United States)

    Zhang, Xiao-Dan; Zheng, Xin-Xia; Xu, Sheng-Zhi; Lin, Quan; Wei, Chang-Chun; Sun, Jian; Geng, Xin-Hua; Zhao, Ying

    2011-10-01

    We report on the development of single chamber deposition of microcrystalline and micromorph tandem solar cells directly onto low-cost glass substrates. The cells have pin single-junction or pin/pin double-junction structures on glass substrates coated with a transparent conductive oxide layer such as SnO2 or ZnO. By controlling boron and phosphorus contaminations, a single-junction microcrystalline silicon cell with a conversion efficiency of 7.47% is achieved with an i-layer thickness of 1.2 μm. In tandem devices, by thickness optimization of the microcrystalline silicon bottom solar cell, we obtained an initial conversion efficiency of 9.91% with an aluminum (Al) back reflector without a dielectric layer. In order to enhance the performance of the tandem solar cells, an improved light trapping structure with a ZnO/Al back reflector is used. As a result, a tandem solar cell with 11.04% of initial conversion efficiency has been obtained.

  12. Asymmetric and double-cathode-pad wire chambers for the LHCb muon system

    CERN Document Server

    Kachtchouk, A; Riegler, W; Schmidt, B; Schneider, T; Souvorov, V

    2005-01-01

    We present results from two types of Multi-Wire Proportional Chambers (MWPCs) with wire pitch of 1.5 mm and cathode–cathode distance of 5 mm intended for triggering purposes in the LHCb experiment. Both prototypes use cathode readout because this allows arbitrary segmentation in order to achieve the required granularity. One MWPC prototype uses a symmetric wire–cathode distance (2.5/2.5 mm) with double cathode readout, which doubles the signal compared to reading only one cathode. The second prototype uses an asymmetric wire–cathode distance (1.25/3.75 mm) with single cathode readout which also doubles the signal and in addition reduces the width of the induced charge distribution and therefore reduces the crosstalk for small cathode pads. We also performed a dedicated optimization of readout traces and guard traces in order to reduce the pad–pad crosstalk. Both prototypes show a few hundred volts of operating plateau defined as the region with 99% efficiency in a 20 ns time window. Close to the plate...

  13. Data registration units of a modified magnetostrictive multiwire spark chamber system of the ''Foton'' set-up

    International Nuclear Information System (INIS)

    Data registration units of a modified magnetostrictive spark chamber system of the ''Foton'' set-up are described. The circuits, the specifications and time diagrams of time converters and control Units of recording appraratus are given. The P101M time-digital converter (TDC) allows one to register 4 ''sparks'', the P105 TDG-4x16 ''sparks'' at a duration coding interval up to 819 mks. The coding frequency is 20 MHz. The units could be used in parallel-sequential units and parallel registration systems. The G-104 test generator is used to test the registration electronic equipment. It generates the pulse sequence with adjustable number and time interval duration, which stability is determined by parameters of a master generator

  14. Construction, test and operation in a high intensity beam of a small system of microstrip gas chambers

    CERN Document Server

    Barr, A J; Boimska, B; Bouclier, Roger; Braem, André; Camps, C; Capéans-Garrido, M; Commichau, V; Dominik, Wojciech; Flügge, G; Gómez, F; Hammarström, R; Hangarter, K; Hoch, M; Labbé, J C; Macke, D; Manzin, G; Meijers, F; Million, Gilbert; Mühlemann, K; Nagaslaev, V P; Peisert, Anna; Ropelewski, Leszek; Runólfsson, O; Sauli, Fabio; Schulte, R; Schulz, M; Sharma, A; Shekhtman, L I; Wolff, C

    1998-01-01

    We describe the construction, test and installation procedures, and the experience gained with the operation of a small but complete system of high rate Micro-Strip Gas Chambers, made on thin boro-silicate glass with a diamond-like coating with chromium or gold strips. A set of detectors, fully equipped with readout electronics and each with an active area of 100x100 mm2, was exposed during six months to a high intensity muon beam at CERN with a peak intensity of ~104 mm-2s-1. Continuous monitoring of the performance of the chambers during the beam runs allowed the evaluation of detection efficiency and the monitoring of accidental rates, as well as the study of ambient induced variations and aging in realistic beam conditions. No significant difference has been found in the operation of under- and over-coated plates. Efficiencies could reach ~98% in best operating conditions, although local lower values were often observed due to missing channels (open strips, broken bonds and dead electronic channels). The ...

  15. Inflammatory Response of Human Gestational Membranes to Ureaplasma parvum Using a Novel Dual-Chamber Tissue Explant System.

    Science.gov (United States)

    Potts, Lauren C; Feng, Liping; Seed, Patrick C; Jayes, Friederike L; Kuchibhatla, Maragatha; Antczak, Brian; Nazzal, Matthew K; Murtha, Amy P

    2016-05-01

    Preterm premature rupture of membranes (PPROM) is often associated with intra-amniotic inflammation and infection. Current understanding of the pathogenesis of PPROM includes activation of pro-inflammatory cytokines and proteolytic enzymes leading to compromise of membrane integrity. The impact of exposure to bacterial pathogens, including Ureaplasma parvum, on gestational membranes is poorly understood. Our objective was to develop a dual-chamber system to characterize the inflammatory response of gestational membranes to U. parvum in a directional nature. Full-thickness human gestational membrane explants, with either choriodecidua or amnion oriented superiorly, were suspended between two washers in a cylindrical device, creating two distinct compartments. Brilliant green dye was introduced into the top chamber to assess the integrity of the system. Tissue viability was evaluated after 72 h using a colorimetric cell proliferation assay. Choriodecidua or amnion was exposed to three doses of U. parvum and incubated for 24 h. Following treatment, media from each compartment were used for quantification of U. parvum (quantitative PCR), interleukin (IL)-8 (enzyme-linked immunosorbent assay), and matrix metalloproteinase (MMP)-2 and MMP-9 activity (zymography). We observed that system integrity and explant viability were maintained over 72 h. Dose-dependent increases in recovered U. parvum, IL-8 concentration, and MMP-2 activity were detected in both compartments. Significant differences in IL-8 concentration and MMP-9 activity were found between the choriodecidua and amnion. This tissue explant system can be used to investigate the inflammatory consequences of directional bacterial exposure for gestational membranes and provides insight into the pathogenesis of PPROM and infectious complications of pregnancy. PMID:27009041

  16. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Michael Christian

    2009-02-27

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The present thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold,HV) was investigated quantitatively. Also detailed studies on single cells, qualified as ''dead'' and ''noisy'' were done. For the DAQ tests a flexible hardware and software environment was needed. The organization and installation of the supplied electronics, as well as the software development was realized within the scope of this thesis. The DCS tests were focused on the local gas pressure read-out components, attached directly to the chamber: pressure sensor, manifolds and the pressure ADC (PADC). At first it was crucial to proof, that the calibration of the mentioned chamber components for the gas pressure measurement is valid. The sensor calibration data were checked and possible differences in their response to the same pressure were studied. The analysis of the results indicated that the sensor output depends also on the ambient temperature, a new experience which implied an additional pedestal measurement of the chamber gas pressure

  17. Scanning bubble chamber pictures

    CERN Multimedia

    1974-01-01

    These were taken at the 2 m hydrogen bubble chamber. The photo shows an early Shiva system where the pre-measurements needed to qualify the event were done manually (cf photo 7408136X). The scanning tables were located in bld. 12. Gilberte Saulmier sits on foreground, Inge Arents at centre.

  18. DESIGN, FABRICATION, ASSEMBLY AND BENCH TESTING OF A TEXACO INFRARED RATIO PYROMETER SYSTEM FOR THE MEASUREMENT OF REACTION CHAMBER TEMPERATURE

    Energy Technology Data Exchange (ETDEWEB)

    Tom Leininger

    2001-03-31

    Reliable measurement of gasifier reaction chamber temperature is important for the proper operation of slagging, entrained-flow gasification processes. Historically, thermocouples have been used as the main measurement technique, with the temperature inferred from syngas methane concentration being used as a backup measurement. While these have been sufficient for plant operation in many cases, both techniques suffer from limitations. The response time of methane measurements is too slow to detect rapid upset conditions, and thermocouples are subject to long-term drift, as well as slag attack, which eventually leads to failure of the thermocouple. Texaco's Montebello Technology Center (MTC) has developed an infrared ratio pyrometer system for measuring gasifier reaction chamber temperature. This system has a faster response time than both methane and thermocouples, and has been demonstrated to provide reliable temperature measurements for longer periods of time when compared to thermocouples installed in the same MTC gasifier. In addition, the system can be applied to commercial gasifiers without any significant scale-up issues. The major equipment items, the purge system, and the safety shutdown system in a commercial plant are essentially identical to the prototypes at MTC. The desired result of this DOE program is ''a bench-scale prototype, either assembled or with critical components (laboratory) tested in a convincing manner.'' The prototype of the pyrometer system (including gasifier optical access port) that was designed, assembled and tested for this program, has had previous prototypes that have been built and successfully tested under actual coal and coke gasification conditions in three pilot units at MTC. It was the intent of the work performed under the auspices of this program to review and update the existing design, and to fabricate and bench test an updated system that can be field tested in one or more commercial gasifiers

  19. RESEARCH OF EFFICIENCY OF WALL-MOUNTED BOILERS WITH SEALED CHAMBERS USED AS FLAT HEATING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Khavanov Pavel Aleksandrovich

    2012-12-01

    the heating system analysis and to define the area of application of various systems of heat supply. The principal decision based on the basis of the above analysis is the decision to install an independent or a centralized system of heat supply.

  20. Investigation of the neutron contamination in IMRT deliveries with a paired magnesium and boron coated magnesium ionization chamber system

    International Nuclear Information System (INIS)

    Background and Purpose: Photon beams used in IMRT treatments with high energies (>10 MV) are contaminated with neutrons. Measurement of this neutron dose is of significance to the overall risk estimate of high energy radiotherapy. Materials and methods: For measuring neutron doses a paired magnesium and boron coated magnesium chamber system was used. All measurements were performed inside the solid water phantom EasyCube using abdominal extensions. 4 different clinical treatment plans were studied. Results: The measured neutron dose showed to be homogeneous inside the phantom and increased with increased number of applied monitor units. The sum over all fractions showed neutron doses of 1 - 2 mGy, depending on the kind of treatment. Conclusions: Using large conversion factors of 25 Sv/Gy, none of the studied treatment plans exceeded dose equivalents of 50 mSv for the whole treatment. This dose equivalent has to be considered whole body dose due to the homogeneous distribution of neutrons

  1. Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams; Projeto, construcao e caracterizacao de camaras de ionizacao para utilizacao como sistemas padroes em feixes de radiacao X e gama

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula

    2013-07-01

    Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this PhD program. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system. (author)

  2. Vacuum and gas flow control system for a MWPC and an axial chamber

    International Nuclear Information System (INIS)

    An automatic system that controls the vacuum, gas flow and pressure regulation operations has been constructed for two gas-filled detectors operating in series. To keep constant the amount of the gas in the detectors the pressure values are adjusted as a function of the temperature. The system is based on a CPU (Motorola 68000) in a VME bus. The performances of this system have been tested with satisfactory results

  3. Imaging System with Modified-Pressure Chamber for Crack Detection in Shell-Eggs

    Science.gov (United States)

    To detect checks and/or cracks in shell eggs, the egg industry is using high-speed acoustic systems. Prior to shipment, human graders candle a small subset of eggs to ensure that the high-speed systems are operating within specifications for a given grade of egg (e.g., Grade A Large Eggs). In addit...

  4. A novel convolution-based approach to address ionization chamber volume averaging effect in model-based treatment planning systems

    International Nuclear Information System (INIS)

    The ionization chamber volume averaging effect is a well-known issue without an elegant solution. The purpose of this study is to propose a novel convolution-based approach to address the volume averaging effect in model-based treatment planning systems (TPSs). Ionization chamber-measured beam profiles can be regarded as the convolution between the detector response function and the implicit real profiles. Existing approaches address the issue by trying to remove the volume averaging effect from the measurement. In contrast, our proposed method imports the measured profiles directly into the TPS and addresses the problem by reoptimizing pertinent parameters of the TPS beam model. In the iterative beam modeling process, the TPS-calculated beam profiles are convolved with the same detector response function. Beam model parameters responsible for the penumbra are optimized to drive the convolved profiles to match the measured profiles. Since the convolved and the measured profiles are subject to identical volume averaging effect, the calculated profiles match the real profiles when the optimization converges. The method was applied to reoptimize a CC13 beam model commissioned with profiles measured with a standard ionization chamber (Scanditronix Wellhofer, Bartlett, TN). The reoptimized beam model was validated by comparing the TPS-calculated profiles with diode-measured profiles. Its performance in intensity-modulated radiation therapy (IMRT) quality assurance (QA) for ten head-and-neck patients was compared with the CC13 beam model and a clinical beam model (manually optimized, clinically proven) using standard Gamma comparisons. The beam profiles calculated with the reoptimized beam model showed excellent agreement with diode measurement at all measured geometries. Performance of the reoptimized beam model was comparable with that of the clinical beam model in IMRT QA. The average passing rates using the reoptimized beam model increased substantially from 92.1% to

  5. A novel convolution-based approach to address ionization chamber volume averaging effect in model-based treatment planning systems

    Science.gov (United States)

    Barraclough, Brendan; Li, Jonathan G.; Lebron, Sharon; Fan, Qiyong; Liu, Chihray; Yan, Guanghua

    2015-08-01

    The ionization chamber volume averaging effect is a well-known issue without an elegant solution. The purpose of this study is to propose a novel convolution-based approach to address the volume averaging effect in model-based treatment planning systems (TPSs). Ionization chamber-measured beam profiles can be regarded as the convolution between the detector response function and the implicit real profiles. Existing approaches address the issue by trying to remove the volume averaging effect from the measurement. In contrast, our proposed method imports the measured profiles directly into the TPS and addresses the problem by reoptimizing pertinent parameters of the TPS beam model. In the iterative beam modeling process, the TPS-calculated beam profiles are convolved with the same detector response function. Beam model parameters responsible for the penumbra are optimized to drive the convolved profiles to match the measured profiles. Since the convolved and the measured profiles are subject to identical volume averaging effect, the calculated profiles match the real profiles when the optimization converges. The method was applied to reoptimize a CC13 beam model commissioned with profiles measured with a standard ionization chamber (Scanditronix Wellhofer, Bartlett, TN). The reoptimized beam model was validated by comparing the TPS-calculated profiles with diode-measured profiles. Its performance in intensity-modulated radiation therapy (IMRT) quality assurance (QA) for ten head-and-neck patients was compared with the CC13 beam model and a clinical beam model (manually optimized, clinically proven) using standard Gamma comparisons. The beam profiles calculated with the reoptimized beam model showed excellent agreement with diode measurement at all measured geometries. Performance of the reoptimized beam model was comparable with that of the clinical beam model in IMRT QA. The average passing rates using the reoptimized beam model increased substantially from 92.1% to

  6. A spark-chamber spectrometer

    International Nuclear Information System (INIS)

    A programme of developing techniques for the construction and use of spark chambers in high-energy physics experiments has been undertaken. Several methods of construction have been tested and found satisfactory. One method is to cement aluminium plates to frames made from glass or Plexiglas strips. Another is to place the aluminium plates in grooves machined in Plexiglas, forming a ''shelf'' design. A chamber made of rows of wires was successfully operated with a He-alcohol mixture. These chambers can either be filled with gas and sealed, or gas can be passed through them continuously. Chambers have been constructed with plates of various thicknesses ranging from 0.032 in downwards. The operation of the chambers with various spacings between the plates was also investigated. The performance of these chambers, when filled with several different gases (Ne, He, A) and with gas-alcohol mixtures, has been investigated. Several methods of applying high-voltage pulses to the chambers have been attempted. The results of these investigations are presented. Spark chambers placed in a magnetic field can be used in principle to determine the momentum of charged particles and if lead converter-plates are incorporated with them, the resulting system should serve as a gamma-ray spectrometer of high resolution and high efficiency. A magnet with an 18-in useful diameter and a 13000-G field is being fitted with spark chambers, whose performance will be tested with cosmic rays and with an accelerator beam. Results from such tests are presented. (author)

  7. Probing microelectromechanical systems in an environmentally controlled chamber using long working distance interferometry.

    Science.gov (United States)

    Soylemez, E; Plass, R A; Ashurst, W R; de Boer, M P

    2013-07-01

    It is well known that the environment in which micromechanical systems operate significantly affects their performance. It is, therefore, important to characterize micromachine behavior in environments where the humidity, pressure, and chemical composition of the ambient can be precisely controlled. Achieving such a level of environmental control presents significant challenges in view of the required instrumentation. To that end, a custom micromachine characterization system is built that allows for full environmental control (pressure, humidity, and gas composition) while retaining full micromachine characterization techniques (long working distance interferometry, electrical probe connectivity, actuation scripting capability). The system also includes an effective in situ surface cleaning mechanism. As an example of the system's utility, a microcantilever crack healing experiment is conducted and surface adhesion energy measurements are tracked over time after a step change in humidity is applied. PMID:23902098

  8. Evaluating Effective Factors on Executive of Digital Integrate System in Isfahan chamber of commerce Companies

    OpenAIRE

    Rasool Shafieyoun; Fariddeddin Allammeh Haery; Mohammad Asemi

    2014-01-01

    Emergence and development of E-commerce through internet applications in new era has made a wide change in individual, organisational, national and global life. Today, companies' integrated information systems move towards digital data. This data encompass all of files, records, emails and web pages. The study objective is finding and presenting facts and limits of execution of integrated digital systems through identifying affecting challenges of effective execution on it and factors prevent...

  9. Demonstration of a light-redirecting skylight system at the Palm Springs Chamber of Commerce

    Energy Technology Data Exchange (ETDEWEB)

    Lee, E.S.; Beltran, L.O.; Selkowitz, S.E. [Lawrence Berkeley National Lab., CA (United States); Lau, H.; Ander, G.D. [Southern California Edison, San Dimas, CA (United States)

    1996-05-01

    As part of a demonstration project to provide a comprehensive energy upgrade to a 294 m{sup 2} (3168 ft{sup 2}) commercial building, an advanced skylight design was developed using optical light control materials and geometry to provide daylight to two adjoining offices. The skylight system was developed using outdoor physical model tests and simulation tools Limited on-site measurements and occupant polls were conducted. Market issues were addressed. The skylight systems were found to improve lighting quality and to control excessive daylight illuminance levels compared to a conventional diffusing bubble skylight. Daylighting principles developed in earlier work for vertical glazing systems (light shelves and light pipes) were shown to be applicable in skylight designs at full-scale.

  10. Development of a monitor system for gas based detectors and measurement of electron attachment in the chamber gas

    International Nuclear Information System (INIS)

    In the framework of an international collaboration a new electron-positron linear accelerator (ILC) with a c. m. energy up to 500 GeV is planned. For the International Large Detector Concept (ILD) a time projection chamber (TPC) shall perform precise measurements of the particle tracks. In order to fulfil the high requirements on the resolution, a microstructure gas-amplification system is used for read-out. For research and development of the detector principle for the application at the ILC at DESY a large TPC prototype is developed. For the operation of the detector it is necessary to monitor its state and especially that of the measurement gas. For this purpose in the framework of this thesis a slow control system is built, which shall make possible for the different collaboration partners to operate the prototype and to integrate the slow control data into their measurement. For this with an object-oriented control system a graphic user interface was created, which makes an overview over the applied measurement devices and a driving allows. Furthermore the influence of impurities of the gas mixture by oxygen was studied. For this with a small TPC prototype measurements of the electron attachment coefficient at different oxygen concentrations were performed with a magnetic flux density of 4 T. From the amplitude of the measurement signal a rate for the electron attachment could be determined. The values obtained for this agree sufficiently in comparison with literature values

  11. Development of a Configurable Growth Chamber with a Computer Vision System to Study Circadian Rhythm in Plants

    Directory of Open Access Journals (Sweden)

    Marcos Egea-Cortines

    2012-11-01

    Full Text Available Plant development is the result of an endogenous morphogenetic program that integrates environmental signals. The so-called circadian clock is a set of genes that integrates environmental inputs into an internal pacing system that gates growth and other outputs. Study of circadian growth responses requires high sampling rates to detect changes in growth and avoid aliasing. We have developed a flexible configurable growth chamber comprising a computer vision system that allows sampling rates ranging between one image per 30 s to hours/days. The vision system has a controlled illumination system, which allows the user to set up different configurations. The illumination system used emits a combination of wavelengths ensuring the optimal growth of species under analysis. In order to obtain high contrast of captured images, the capture system is composed of two CCD cameras, for day and night periods. Depending on the sample type, a flexible image processing software calculates different parameters based on geometric calculations. As a proof of concept we tested the system in three different plant tissues, growth of petunia- and snapdragon (Antirrhinum majus flowers and of cladodes from the cactus Opuntia ficus-indica. We found that petunia flowers grow at a steady pace and display a strong growth increase in the early morning, whereas Opuntia cladode growth turned out not to follow a circadian growth pattern under the growth conditions imposed. Furthermore we were able to identify a decoupling of increase in area and length indicating that two independent growth processes are responsible for the final size and shape of the cladode.

  12. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  13. Ames Culture Chamber System: Enabling Model Organism Research Aboard the international Space Station

    Science.gov (United States)

    Steele, Marianne

    2014-01-01

    Understanding the genetic, physiological, and behavioral effects of spaceflight on living organisms and elucidating the molecular mechanisms that underlie these effects are high priorities for NASA. Certain organisms, known as model organisms, are widely studied to help researchers better understand how all biological systems function. Small model organisms such as nem-atodes, slime mold, bacteria, green algae, yeast, and moss can be used to study the effects of micro- and reduced gravity at both the cellular and systems level over multiple generations. Many model organisms have sequenced genomes and published data sets on their transcriptomes and proteomes that enable scientific investigations of the molecular mechanisms underlying the adaptations of these organisms to space flight.

  14. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  15. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  16. Production of long-strip multi-gap resistive plate chamber module for the STAR-MTD system

    International Nuclear Information System (INIS)

    A new Long-strip Multi-gap Resistive Plate Chamber (LMRPC) prototype with 5 gas gaps has been developed for the Muon Telescope Detector (MTD) of the STAR experiment at RHIC in order to reduce the working High Voltage (HV) of previous design. Technical specifications related to the final infrastructure present in the experiment have motivated this effort. Its performance has been measured with cosmic rays. The efficiency of this prototype can reach 98% and the time resolution is around 95 ps. It shows a good uniformity among strips. The noise level is less than 0.2 Hz/cm2. The signal transmission and crosstalk of the modules was measured with a vector network analyzer, showing a good match with simulations within the amplifier bandwidth. A new cosmic-ray test system with long scintillators has been developed to accelerate the Quality Control (QC) process during the mass production of STAR-MTD. A selection of perpendicular cosmic-ray events for more accurate evaluation of the time resolution is achieved. The time resolution with this method is better, albeit with larger error, than the result obtained without any selection. A new spacer is used, resulting in a much reduced streamer ratio at comparable fields. Thirty-two modules have been built with the new spacer by the middle of April of 2012. They have been tested and they all have passed the QC.

  17. National Ignition Facility Target Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-10-05

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This

  18. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  19. Establishment of Airborne Nanoparticle Exposure Chamber System to Assess Nano TiO2 Induced Mice Lung Effects

    Science.gov (United States)

    Chen, Chia-Hua; Li, Jui-Ping; Huang, Nai-Chun; Yang, Chung-Shi; Chen, Jen-Kun

    2011-12-01

    A great many governments have schemed their top priority to support the research and development of emerging nanotechnology, which lead to increasing products containing nanomaterials. However, platforms and protocols to evaluate the safety of nanomaterials are not yet established. We therefore design and fabricate a nanoparticle exposure chamber system (NECS) and try to standardize protocols to assess potential health risk of inhalable nanoparticles. This platform comprises: (1) nano-aerosol generators to produce homogeneous airborne nanoparticles, (2) double isolated container to prevent from unexpected exposure to humans, (3) gas supply system for housing animals or incubating cultured cells, and (4) system for automatic control and airborne nanoparticle analysis. The NECS providing multiple functions includes: (1) a secure environment to handle nanomaterials, (2) real-time measurement for the size and distribution of airborne nanoparticles, (3) SOP of safety evaluation for nanomaterials, and (4) key technology for the development of inhalable pharmaceuticals. We used NECS to mimic occupational environment for exploring potential adverse effects of TiO2 nanoparticles. The adult male ICR mice were exposed to 25nm, well-characterized TiO2 particles for 1 and 4 weeks. More than 90% of the inhaled TiO2 nanoparticles deposit in lung tissue, which tends to be captured by alveolar macrophages. Pulmonary function test does not show significant physiological changes between one and 4 weeks exposure. For plasma biochemistry analysis, there are no obvious inflammation responses after exposure for one and 4 weeks; however, disruption of alveolar septa and increased thickness of alveolar epithelial cells were observed. According to our results, the NECS together with our protocols show comprehensive integration and ideally fit the standard of OECD guildelines-TG403, TG412, TG413; it can be further customized to fulfill diverse demands of industry, government, and third party

  20. Tohoku one meter bubble chamber

    International Nuclear Information System (INIS)

    At the request of Tohoku University and the National Laboratory for High Energy Physics, IHI has developed a complete freon bubble chamber system successfully, which is used for photo analysis of elementary particles physics. This system will be delivered to Fermi National Accelerator Laboratory (FNAL) in Illinois (U.S.A.) and will be coupled with the superconducting accelerator (TEVATRON) for the study of elementary particles. The total system of the freon bubble chamber is composed of a stainless steel casting spherical bubble chamber with a diameter of about one meter, an expansion system for freon pressure control, hydraulic system for driving an expansion piston, a freon feed system, a temperature control system, an overall control system as well as camera and flashlight for photograph. (author)

  1. Using of the serial graph connection for the determination of the relative permeability of reservoir rocks; Utilizacao do grafo de conexao serial para a determinacao da permeabilidade relativa de rochas reservatorio

    Energy Technology Data Exchange (ETDEWEB)

    Bueno, A.D. [Universidade Estadual do Norte Fluminense, Macae, RJ (Brazil). Lab. de Engenharia e Exploracao e Producao de Petroleo (LENEP); Philippi, P.C. [Santa Catarina Univ., Florianopolis, SC (Brazil). Lab. de Meios Porosos e Propriedades Termofisicas dos Materiais (LMPT)]. E-mail: philippi@lmpt.ufsc.br

    2003-07-01

    In recent work Bueno and others (Bueno A.D., Magnani F. S., Philippi P.C, 'Metodo para Determinacao da Permeabilidade Relativa de Rochas Reservatorio de Petroleo Atraves da Analise de Imagens Reconstruidas, 'IX Congresso Brasileiro de Engenharia e Ciencias Termicas - ENCIT, Caxambu - MG - Brasil, 2002), presented a methodology for the determination of relative permeability of reservoir rocks, using an opening algorithm to determine the equilibrium configuration of fluid phases, water and oil in reconstructed 3D media and the serial graph connection method to determine the permeabilities of the phase, at each pressure step. In this paper, the first results of application of this methodology, and comparison with experimental results are presented. (author)

  2. Validation of the extension of the range of application and of the single system of injection for the determination of total nitrogen in petroleum and its derivatives by chemiluminescence; Validacao da ampliacao da faixa de aplicacao e do sistema unico de injecao para a determinacao de nitrogenio total em petroleos e derivados por quimiluminescencia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria de Fatima Pereira dos [Fundacao Gorceix, Ouro Preto, MG(Brazil)]. E-mail: santos@cenpes.petrobras.com.br; Tamanqueira, Juliana Boechat [Universidade Federal Fluminense, Niteroi, RJ (Brazil); Magalhaes, Julio Cesar Dias [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Avaliacao de Petroleo; Oliveira, Elcio Cruz de [Transpetro, Rio de Janeiro, RJ (Brazil). Logistica e Planejamento; Vaitsman, Delmo Santiago [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Quimica. Dept. de Quimica Analitica

    2003-12-01

    With the objectives of using a single system of injection and of extending the range of application for the method ASTM D4629/02 'Total Nitrogen in Petroleum Derivatives by the System of Injection with a Syringe and Detection by Chemo- Luminescence', it was studied a procedure by statistical validation with the objective of guaranteeing the analytical reliability of the assay and allowing the inclusion of samples of petroleum and heavy derivatives in one single methodology. The determination of total nitrogen for petroleum and derivatives is traditionally assayed using the method of Kjeldahl - a time-consuming methodology that requires a large amount of time for giving the final result, at the same time that is not recommended for concentrations below 0.1%w/w, which does not meet the requirements for the specifications of the product, in the petroleum industry. An alternative for the method of Kjeldahl is the pyro-chemo luminescence, which allows the achievement of more repetitive results for total nitrogen. In the detection of nitrogen, the technique combines the reliability of oxidative combustion with the sensitivity of chemiluminescence. Therefore, it was developed a protocol of validation in the methodology ASTM D4629/02 for the validation of the extension of the range of application and for the evaluation of the performance of the equipment in analytical conditions, according to the calibration curve. (author)

  3. The HERMES Back Drift Chambers

    OpenAIRE

    al, S. Bernreuther et

    1998-01-01

    The tracking system of the HERMES spectrometer behind the bending magnet consists of two pairs of large planar 6-plane drift chambers. The design and performance of these chambers is described. This description comprises details on the mechanical and electronical design, information about the gas mixture used and its properties, results on alignment, calibration, resolution, and efficiencies, and a discussion of the experience gained through the first three years of operation.

  4. An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system.

    Science.gov (United States)

    Herman, Daniel A; Gallimore, Alec D

    2008-01-01

    Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8 x 10(12) cm(-3) on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates. PMID:18248026

  5. An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system

    International Nuclear Information System (INIS)

    Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8x1012 cm-3 on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates

  6. Performance of the new small-strip Thin Gap Chamber for the ATLAS Muon System at the LHC

    Science.gov (United States)

    Bellerive, Alain; Atlas Nsw Stgc Group Collaboration

    2016-03-01

    The instantaneous luminosity of the Large Hadron Collider (LHC) at CERN will be increased up to a factor of five with respect to the design value by undergoing an extensive upgrade program. The largest phase-1 upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward region with the so-called New Small Wheel (NSW). The NSW consists of layers of Micromegas and small-strip Thin Gap Chambers (sTGC), both providing trigger and tracking capabilities. The precision reconstruction of tracks requires a spatial resolution of about 100 microns, and the trigger track segments have to be reconstructed with an angular resolution of approximately 1 mrad. The sTGC structure consists of a grid of gold-plated tungsten wires sandwiched between two resistive cathode planes. The precision cathode plane has strips with a 3.2mm pitch for precision readout and the cathode plane on the other side has pads for triggering. The pads are used to produce a 3-out-of-4 coincidence to identify muon tracks in an sTGC quadruplet. A full size sTGC quadruplet has been constructed and equipped with the first prototype of dedicated front-end electronics. The design of the sTGC will be described. The performance of the sTGC quadruplet has been characterized with data collected at the Fermilab and CERN test beam facilities. Spatial resolution and trigger efficiency results will be presented. An overview of the simulation and digitization model of the sTGC will also be summarized.

  7. Design of an ultrahigh vacuum transfer mechanism to interconnect an oxide molecular beam epitaxy growth chamber and an x-ray photoemission spectroscopy analysis system

    International Nuclear Information System (INIS)

    We designed a mechanism and the accompanying sample holders to transfer between a VEECO 930 oxide molecular beam epitaxy (MBE) and a PHI Versa Probe X-ray photoemission spectroscopy (XPS) chamber within a multiple station growth, processing, and analysis system through ultrahigh vacuum (UHV). The mechanism consists of four parts: (1) a platen compatible with the MBE growth stage, (2) a platen compatible with the XPS analysis stage, (3) a sample coupon that is transferred between the two platens, and (4) the accompanying UHV transfer line. The mechanism offers a robust design that enables transfer back and forth between the growth chamber and the analysis chamber, and yet is flexible enough to allow transfer between standard sample holders for thin film growth and masked sample holders for making electrical contacts and Schottky junctions, all without breaking vacuum. We used this mechanism to transfer a barium strontium titanate thin film into the XPS analysis chamber and performed XPS measurements before and after exposing the sample to the air. After air exposure, a thin overlayer of carbon was found to form and a significant shift (∼1 eV) in the core level binding energies was observed.

  8. Semiautomatic measuring system for bubble chamber film analysis under control of a multi-task operating system

    International Nuclear Information System (INIS)

    We have constructed a semiautomatic measuring system by applying the on-line diagnosis method developed previously for manual digitizer to a new track follower, SWEEPNIK. The aim of our system is that all tracks of an event are automatically measured once an interaction vertex is given (Vertex Guidance). The on-line diagnosis gives the following two features to this system. One is a diagnosis of the accuracy of measured data. The other is a diagnosis to reject a spurious track. The former is essential to obtain accurate data. The latter makes the Vertex Guidance reliable. With the help of the multi-task operating system, the on-line diagnosis scarcely increases the overall measuring time. An analysis of 1339 two-prong events shows that the passing rate of the measured events through a general reconstruction program amounts to 95 percent and that we do not need to remeasure in practice. (author)

  9. An experimental system for the quantitative 14C labelling of whole trees in situ [assimilation chamber, control of CO2 level

    International Nuclear Information System (INIS)

    The first part of this paper provides a brief review of the requirements that apply to 14C-labelling chamber technology, particularly for tree labelling, and of the means that can be used to meet them. Two main points are considered: the quality of the plant chamber environment - the necessity of thermal and hygrometric regulations is discussed - and the possibility of determining the exact amount of 14CO2 assimilated by the plant. The authors then describe a simple system allowing the quantitative labelling of entire trees, without temperature- or hygrometry-regulating devices which can be used in the morning. The CO2 concentration is maintained at its natural level throughout the labelling procedure through an injection of cold CO2 operated by an IRGA-driven computer. This system was successfully used for the labelling of grafted walnut trees. (author)

  10. Precision Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs measurements and calibration of antennas for satellites and aircraft or groundbased systems. The chamber is primarily used for optimizing antenna...

  11. Wire chambers revisited

    International Nuclear Information System (INIS)

    Multiwire proportional chambers (MWPCs) have long been used as position-sensitive charged particle detectors in nuclear and high-energy physics. MWPCs are large-area gas-filled ionisation chambers in which large arrays of fine wires are used to measure the position of ionisation produced in the gas by the passage of charged particles. The important properties of MWPCs are high-spatial-resolution, large-area, high-count-rate performance at low cost. For research applications, detectors several metres square have been built and small-area detectors have a charged particle resolution of 0.4 mm at a count rate of several million per second. Modification is required to MWPCs for nuclear medicine imaging. A gamma rays or X-rays cannot be detected directly, they must be converted into photo- or Compton scatter electrons. Photon-electron conversion requires the use of high atomic number materials in the body of the chamber. Pressurised xenon is the most useful form of ''gas only'' photon-electron convertor and has been used successfully in a gamma camera for the detection of gamma rays at energies below 100 keV. This camera has been developed specifically for high-count-rate first-pass cardiac imaging. This high-pressure xenon gas MWPC is the key to a highly competitive system which can outperform scintillator-based systems. The count rate performance is close to a million counts per second and the intrinsic spatial resolution is better than the best scintillator-based camera.The only clinical detector have been developed for positron emission tomography, where thin lead or lead-glass can provide an acceptable convertor for 511 keV photons. Two MWPC positron cameras have been evaluated clinically and one is now routine use in clinical oncology. The problems of detection efficiency have not been solved by these detectors although reliability and large-area PET imaging have been proven. (orig./HSI)

  12. Activity measurements of radioactive solutions by liquid scintillation counting and pressurized ionization chambers and Monte Carlo simulations of source-detector systems for metrology

    International Nuclear Information System (INIS)

    The research works 'Activity measurements of radioactive solutions by liquid scintillation and pressurized ionization chambers and Monte Carlo simulations of source-detector systems' was presented for the graduation: 'Habilitation a diriger des recherches'. The common thread of both themes liquid scintillation counting and pressurized ionization chambers lies in the improvement of the techniques of radionuclide activity measurement. Metrology of ionization radiation intervenes in numerous domains, in the research, in the industry including the environment and the health, which are subjects of constant concern for the world population these last years. In this big variety of applications answers a large number of radionuclides of diverse disintegration scheme and under varied physical forms. The presented works realized within the National Laboratory Henri Becquerel have for objective to assure detector calibration traceability and to improve the methods of activity measurements within the framework of research projects and development. The improvement of the primary and secondary activity measurement methods consists in perfecting the accuracy of the measurements in particular by a better knowledge of the parameters influencing the detector yield. The works of development dealing with liquid scintillation counting concern mainly the study of the response of liquid scintillators to low energy electrons as well as their linear absorption coefficients using synchrotron radiation. The research works on pressurized ionization chambers consist of the study of their response to photons and electrons by experimental measurements compared to the simulation of the source-detector system using Monte Carlo codes. Besides, the design of a new type of ionization chamber with variable pressure is presented. This new project was developed to guarantee the precision of the amount of activity injected into the patient within the framework of diagnosis examination

  13. Dosimetry by paired chambers (TEP-TEG and C-CO2 chamber)

    International Nuclear Information System (INIS)

    Paired chambers are defined as the combination of a neutron and γ sensitive detector and a γ sensitive one, such as the combination of a tissue equivalent ionization chamber (TEP-TEG chamber) and a carbon ionization chamber (C-CO2 chamber). The paired chambers have a feature to be capable of measuring the dose in an irradiation field directly by absorbed dose unit. The authors performed dosimetry by using the paired chambers to investigate the possibility of medical and biological researches by means of the fast neutron beam obtained in the reactor ''Yayoi''. First, the specifications for the paired chambers used, and next, the dose evaluation method are described. The result of dose calibration for the paired chambers shows that the carbon chamber has the reproducibility within 3% deviation and the TEP chamber system has that of 2%. As the examples of measurement, the dosimetry for a living body radiation field by fast neutron beam and that for epithermal neutron irradiation system are reported. The comparison of these dosimetrical results with the other paired chambers seems to show that the satisfactory dosimeter has been produced. The parameters employed for dose conversion are considered to be applicable to the measurement of the epithermal neutron irradiation system. (Wakatsuki, Y.)

  14. TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

    Energy Technology Data Exchange (ETDEWEB)

    Barraclough, B [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL (United States); Li, J; Liu, C; Yan, G [Department of Radiation Oncology, University of Florida, Gainesville, FL (United States)

    2014-06-15

    Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA

  15. TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

    International Nuclear Information System (INIS)

    Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle3), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA

  16. Development of a test system for the analysis of the read-out electronic cabling for the CMS drift tube chambers

    International Nuclear Information System (INIS)

    A test system has been developed for the analysis of the read-out electronics cabling for the CMS drift tube chambers. The read-out electronics will be placed inside some aluminium boxes, so-called Minicrates, which are going to be produced soon at CIEMAT. Due to the difficulty of detecting and repairing errors in the cables once they have been installed and recalling also to the large number of Minicrates that are going to be produced, it was decided to design and develop a test system for testing the cabling before its installation. (Author)

  17. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  18. The systemic exposure to inhaled beclometasone/formoterol pMDI with valved holding chamber is independent of age and body size

    DEFF Research Database (Denmark)

    Govoni, Mirco; Piccinno, Annalisa; Lucci, Germano;

    2015-01-01

    BACKGROUND: Asthma guidelines recommend prescription of inhaled corticosteroids at a reduced dosage in children compared to older patients in order to minimize the systemic exposure and risk of unwanted side effects. In children, pressurized metered dose inhalers (pMDI) are recommended in combina....../formoterol administered via pMDI with AeroChamber Plus™ correlates with the nominal dose independently of patient age and body size. Thus, dose reduction in relation to age when using a pMDI with VHC may be unnecessary for reducing the systemic exposure in children.......BACKGROUND: Asthma guidelines recommend prescription of inhaled corticosteroids at a reduced dosage in children compared to older patients in order to minimize the systemic exposure and risk of unwanted side effects. In children, pressurized metered dose inhalers (pMDI) are recommended in...... combination with a valved holding chamber (VHC) to overcome the problem of coordinating inhalation with actuation. However, the influence of age and body size on the systemic exposure of drugs to be administered via a pMDI with VHC is still not fully elucidated. Therefore, we aimed to compare the systemic...

  19. Prestaciones del Detector Central de Muones del Experimento CMS: las Camaras de Deriva y su Sistema de Trigger (Performance of the Central Muon Detector of the Experiment CMS: the Drift Tube Chambers and its Trigger System)

    CERN Document Server

    Muñoz, Carlos Villanueva

    2007-01-01

    Prestaciones del Detector Central de Muones del Experimento CMS: las Camaras de Deriva y su Sistema de Trigger (Performance of the Central Muon Detector of the Experiment CMS: the Drift Tube Chambers and its Trigger System)

  20. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  1. The TESLA Time Projection Chamber

    OpenAIRE

    Ghodbane, Nabil

    2002-01-01

    A large Time Projection Chamber is proposed as part of the tracking system for a detector at the TESLA electron positron linear collider. Different ongoing R&D studies are reviewed, stressing progress made on a new type readout technique based on Micro-Pattern Gas Detectors.

  2. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  3. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  4. Integration of an optical coherence tomography (OCT) system into a new environmental chamber to facilitate long term in vivo imaging of cardiovascular development in higher vertebrate embryos

    DEFF Research Database (Denmark)

    Thrane, Lars; Happel, Christoph M.; Thommes, Jan;

    2010-01-01

    cardiovascular development. Here we demonstrate, to the best of our knowledge, the first realization of an optical coherence tomography (OCT) system integrated into a new environmental incubation chamber (EIC) to facilitate real-time in vivo imaging of cardiovascular development in chick embryos. The EIC...... provides stable conditions for embryonic development with respect to temperature, humidity, and oxygen levels. An OCT probe is integrated into the EIC and facilitates visualization of embryos at micrometer resolution, including the acquisition of M-mode, Doppler OCT, and Doppler M-mode data....

  5. Engineering verification of the biomass production chamber

    Science.gov (United States)

    Prince, R. P.; Knott, W. M., III; Sager, J. C.; Jones, J. D.

    1992-01-01

    The requirements for life support systems, both biological and physical-chemical, for long-term human attended space missions are under serious study throughout NASA. The KSC 'breadboard' project has focused on biomass production using higher plants for atmospheric regeneration and food production in a special biomass production chamber. This chamber is designed to provide information on food crop growth rate, contaminants in the chamber that alter plant growth requirements for atmospheric regeneration, carbon dioxide consumption, oxygen production, and water utilization. The shape and size, mass, and energy requirements in relation to the overall integrity of the biomass production chamber are under constant study.

  6. Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol - comparison of systems based on membrane desolvation, a spray chamber and direct injection

    DEFF Research Database (Denmark)

    Bendahl, L.; Gammelgaard, Bente

    2005-01-01

    nebuliser (MCN) in combination with a membrane desolvator ( MD), a MCN in combination with a cyclonic spray chamber ( CS) and a direct injection nebuliser ( DIN), respectively. Thirteen selenium standards diluted in 50% methanol were introduced in each system at a flow rate of 50 mu l min(-1). Except for...

  7. Culture of normal human blood cells in a diffusion chamber system II. Lymphocyte and plasma cell kinetics

    International Nuclear Information System (INIS)

    Normal human blood leukocytes were cultured in Millipore diffusion chambers implanted into the peritoneal cavities of irradiated mice. The evaluation of survival and proliferation kinetics of cells in lymphyocytic series suggested that the lymphoid cells are formed from transition of small and/or large lymphocytes, and the lymphoblasts from the lymphoid cells. There was also evidence indicating that some of the cells in these two compartments are formed by proliferation. The evaluation of plasmacytic series suggested that the plasma cells are formed from plasmacytoid-lymphocytes by transition, and the latter from the transition of lymphocytes. In addition, relatively a small fraction of cells in these two compartments are formed by proliferation. mature plasma cells do not and immature plasma cells do proliferate. Estimation of magnitude of plasma cells formed in the cultures at day 18 indicated that at least one plasma cell is formed for every 6 normal human blood lymphocytes introduced into the culture

  8. BEBC bubble chamber

    CERN Multimedia

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  9. High resolution drift chambers

    International Nuclear Information System (INIS)

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  10. Establishment of minimum operational parameters for a high-volume static chamber steam pasteurization system (SPS 400-SC) for beef carcasses to support HACCP programs.

    Science.gov (United States)

    Retzlaff, Deanna; Phebus, Randall; Kastner, Curtis; Marsden, James

    2005-01-01

    A static chamber steam pasteurization unit (SPS 400-SC()) was installed in a high-volume commercial beef slaughter facility. The SPS 400-SC consists of a three-phase carcass treatment cycle of water removal, steam pasteurization, and water chilling. Seven chamber temperatures (71.1, 73.9, 76.7, 79.4, 82.2, 85.0, and 87.8 degrees C) were evaluated at the midline area of pre-rigor beef carcasses. For each temperature evaluated, 20 carcass sides were randomly selected and aseptically sampled by tissue excision immediately before and after steam pasteurization to determine total aerobic bacteria, Enterobacteriaceae, generic E. coli, and total coliform populations. The 87.8 and 85.0 degrees C treatment temperatures were highly effective at reducing total aerobic bacterial populations, with log(10) reductions of 1.4 and 1.5 CFU/cm(2), respectively, from pretreatment mean population levels of 1.7 and 1.9 log10 CFU/cm(2). These temperatures also reduced Enterobacteriaceae, total coliforms, and generic E. coli to undetectable levels (<0.4 CFU/cm(2)) on all carcasses sampled. Treatment at 82.2 was marginally effective at reducing bacterial populations, while 71.1, 73.9, 76.7, and 79.4 degrees C treatments were ineffective at reducing microbial populations. In a Hazard Analysis Critical Control Points (HACCP)-based system employing steam pasteurization of carcasses as a critical control point, a critical limit of 85.0 degrees C as a minimum chamber temperature should be established, with a targeted operating temperature of 87.8 degrees C providing optimum antimicrobial activity. PMID:15992309

  11. Study on the stability of waterpower-speed control system for hydropower station with upstream and downstream surge chambers based on regulation modes

    International Nuclear Information System (INIS)

    In allusion to the hydropower station with upstream and downstream surge chambers, a complete mathematical model of waterpower-speed control system that includes pipeline system and turbine regulation system is established under the premise of the breakthrough of Thoma assumption in this paper. The comprehensive transfer functions and free movement equations that characterize the dynamic characteristics of system are derived when the mode of governor is respectively frequency regulation and power regulation. Then according to Routh- Hurwitz theorem, the stability domain that describes the good or bad of stability is drawn in the coordinate system with the relative areas of upstream and downstream surge chambers as abscissa and ordinate respectively. Finally, the effects of Thoma assumption, flow inertia, regulation modes, and governor parameters on the stability of waterpower-speed control system are analyzed by means of stability domain. The following conclusions have been come to: Thoma assumption made the stability worse. The flow inertia Tw has unfavorable effect on the stability of the two regulation modes. The stability of power regulation mode is obviously superior to frequency regulation mode under the same condition, but the parametric variation sensibility of the former is inferior to the latter. For the governor parameters, the stability continually gets better with the increase of temporary droop bt and damping device time constant Td, while the stability of frequency regulation would get worse with the increase of temporary droop bt when the damping device time constant Td takes small value. As the increase of permanent droop bp, the stability of power regulation mode gets worse

  12. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  13. Development of an α grid ionization chamber

    International Nuclear Information System (INIS)

    The article introduces the parallel grid ionization chamber used to measure the α radioactivity, which has a independent vacuum system. The system is composed of main body of the chamber, gas-filled and electronics system. Energy resolution is 25 keV for 239Pu, background is 4 counts for one hour from 4 MeV to 6 MeV energy range, detect efficiency approach to 50%. The chamber can measure the energy of nuclide, analyze the structure, moreover authenticate both the nuclide and the relative and absolute content. (authors)

  14. System for studies of control strategies applied in the refrigerated chambers Sistema para estudos de estratégias de controle aplicadas em câmaras frias

    Directory of Open Access Journals (Sweden)

    Alexandre Tizzei

    2011-10-01

    Full Text Available The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.O processo de armazenamento refrigerado em câmaras contribui, em grande parte, para a qualidade e a longevidade dos produtos. Nos últimos anos, têm-se intensificado os estudos de estratégias de controle com a finalidade de diminuir a variação da temperatura dentro da câmara de armazenamento e de reduzir o consumo de energia elétrica. Neste trabalho, foi desenvolvido um sistema para aquisição de dados e controle do processo, em linguagem LabVIEW, para ser aplicado no sistema de refrigeração de uma câmara frigorífica de 30m³. A utilização da instrumentação e do aplicativo desenvolvido possibilitou a realização de experimentos científicos, com o objetivo de estudar o comportamento dinâmico do sistema de refrigeração, comparar o desempenho das estratégias de controle da máquina térmica, tanto em função da temperatura controlada, quanto ao consumo de energia elétrica. Neste sistema, foram testadas as estratégias de controle liga-desliga, PID e fuzzy. Em

  15. N2O fluxes over a corn field from an open-path, laser-based eddy covariance system and static chambers

    Science.gov (United States)

    Tao, L.; Pan, D.; Gelfand, I.; Abraha, M.; Moyer, R.; Poe, A.; Sun, K.; Robertson, P.; Zondlo, M. A.

    2015-12-01

    Nitrous oxide (N2O) is important greenhouse and ozone-depleting gase. Although many efforts have been paid to N2O emissions, the spatial and temporal variability of N2O emissions still subject to large uncertainty. Application of the eddy covariance method for N2O emissions research would allow continuous ecosystem level flux measurements. The caveat, however, is need for high precision and high frequency measurements in field. In this study, an open-path, quantum cascade-laser-based eddy covariance N2O sensor has been deployed nearly continuously since May 2015 over a corn field at the W.K. Kellogg Biological Station site in SW Michigan. The field precision of the N2O sensor was assessed to be 0.1 ppbv at 10 Hz, and the total consumption was ~ 40 W, allowing the system to be powered solely by solar panels. The stability of the sensor under different temperature and humidity was tested within an environmental chamber. Spectroscopic experiments and cospectra analyses were carried out to study specific corrections associated with the sensor for eddy covariance techniques, including the line broadening effect due to water vapor and high frequency flux attenuation owning to sample path averaging. Ogive analyses indicated that the high-frequency N2O flux loss due to various damping effects was comparable to those of the CO2 flux. The detection limit of flux was estimated to be 0.3 ng N s-1 m-2 with a flux averaging interval of 30 minutes. The results from the EC system were also compared with ground measurements by standard static chambers (SC). Overall, more than 150 individual chamber measurements were taken within the footprint of the EC system. We found good correlation between the EC and SC methods given the spatiotemporal differences between the two techniques (R2 = 0.75). Both methods detected increased emissions during afternoon as compared to morning and night hours. Differences between EC and SC were also studied by investigating spatial variability with a

  16. Gridded ionization chamber

    International Nuclear Information System (INIS)

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  17. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  18. Calorimetry with flash chambers

    International Nuclear Information System (INIS)

    The flash chambers used in the Fermilab E594 neutrino experiment are described, and their use in a calorimeter discussed. Resolutions obtained with a calibration beam are presented, and comments made about the pattern recognition capabilities of the calorimeter

  19. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  20. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  1. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....

  2. Quantifying detection performance of a passive low-frequency RFID system in an environmental preference chamber for laying hens

    Science.gov (United States)

    Radio Frequency Identification (RFID) systems have been widely used in production livestock systems for identifying, tracing, and registering animals and improving subsidy management. Adaptations have been made to extend RFID technology to animal behavior and welfare research. An RFID system was imp...

  3. Supersonic Jet Interactions in a Plenum Chamber

    Directory of Open Access Journals (Sweden)

    K. M. Venugopal

    2004-07-01

    Full Text Available Understanding thè supersonic jet interactions in a plenum chamber is essential for thè design of hot launch systems. Static tests were conducted in a small-scale rocket motor ioaded with a typical nitramine propellaiit to produce a nozzle exit Mach number of 3. This supersonic jet is made to interact with plenum chambers having both open and closed sides. The distance between thè nozzle exit and thè back piate of plenum chamber are varied from 2. 5 to 7. 0 times thè nozzle exit diameter. The pressure rise in thè plenum chamber was measured using pressure transducers mounted at different locatìons. The pressure-time data were analysed to obtain an insight into thè flow field in thè plenum chamber. The maximum pressure exerted on thè back piate of plenum chamber is about 25-35 per cent. of thè maximum stagnation pressure developed in thè rocket motor. Ten static tests were carried out to obtain thè effect of axial distance between thè nozzle exit and thè plenum chamber back piate, and stagnation pressure in thè rocket motoron thè flow field in thè open-sided and closed-sided plenum chambers configurations.

  4. MAN-IN-SIMULANT TEST (MIST) CHAMBER

    Data.gov (United States)

    Federal Laboratory Consortium — The MIST chamber uses methyl salicylate (oil of wintergreen) vapor as a simulant for HD agent to conduct system level evaluations of chemical protective ensembles....

  5. High Performance Methane Thrust Chamber (HPMTC) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to develop a High-Performance Methane Thrust Chamber (HPMRE) to meet the demands of advanced chemical propulsion systems for deep-space mission...

  6. A time expansion chamber as a vertex detector

    International Nuclear Information System (INIS)

    A high-resolution drift chamber based on the time expansion principle has been built as a vertex detector for the Mark J experiment at DESY. The chamber design and the associated control and readout system are described. Results on chamber performance obtained from test beam measurements and first results from running at PETRA are reported. (orig.)

  7. Installation and Commissioning of the new GLM Implantation Chamber

    CERN Document Server

    Pohl, Christoph

    2016-01-01

    Summer student report about the work with the new implantation chamber for the GLM branch of ISOLDE. In the context of this project an API for the vacuum system of the new chamber was developed and implemented in web application that will be used to control the new implantation chamber at some point.

  8. Quality control of the prostate tumor dosimetry performed by real-time dosimetry system COMPASS transmission chamber

    International Nuclear Information System (INIS)

    The most commonly used methodology for the verification of IMRT planning using radiochromic films and specific measures in a homogeneous phantom which move the control points of treatment. This system has the drawback of using a homogeneous model ignores the effect of the heterogeneities and the peculiarities of the patient's anatomy. This coupled with the fact obtain an evaluation in real time of each treatment fraction led us to use the new system COMPASS (I was Dosimetry) for the validation of planning.

  9. Measurement techniques enhancements for MIMO 4G mobile communication systems. extension of mode stirred reverberation chambers (MSRCs) emulation capabilities

    OpenAIRE

    Sánchez Heredia, Juan Diego

    2012-01-01

    [ENG] Mobile communications have experienced a brutal raise over the past 15 years. What started as a voice communication system (GSM or 2G) has finished yet as a data communication system of any kind, which in some cases has come to replace the conventional cabled data access infrastructure. This change in the use given to mobile devices necessarily entails a change in the underlying technology, which should be capable to provide the transmission speeds that these new applications require. T...

  10. Fabrication and test of a 70000 channels electronic pad readout system for multi-step avalanche chambers

    International Nuclear Information System (INIS)

    A new readout concept based on a custom-design chip containing both analog and digital functions as well as ultra-thin mounting with the chip-on-board technique is presented. The full readout system as well as fabrication and testing is described. A 70000 channels system based on this concept was installed in the WA98 experiment at the CERN SPS. The performance of the readout electronics is presented. (orig.)

  11. A novel non invasive measurement of hemodynamic parameters: Comparison of single-chamber ventricular and dual-chamber pacemaker

    Directory of Open Access Journals (Sweden)

    Ingrid M. Pardede

    2008-03-01

    Full Text Available We carried out a cross sectional study to analyze hemodynamic parameters of single-chamber ventricular pacemaker compared with dual-chamber pacemaker by using thoracic electrical bioimpedance monitoring method (Physio Flow™ - a novel simple non-invasive measurement. A total of 48 consecutive outpatients comprised of 27 single chamber pacemaker and 21 dual chamber were analyzed. We measured cardiac parameters: heart rate, stroke volume index, cardiac output index, estimated ejection fraction, end diastolic volume, early diastolic function ratio, thoracic fluid index, and systemic parameters: left cardiac work index and systemic vascular resistance index. Baseline characteristic and pacemaker indication were similar in both groups. Cardiac parameters assessment revealed no significant difference between single-chamber pacemaker and dual-chamber pacemaker in heart rate, stroke volume index, cardiac index, estimated ejection fraction, end-diastolic volume, thoracic fluid index. There was significantly higher early diastolic function ratio in single-chamber pacemaker compared to dual-chamber pacemaker: 92% (10.2-187.7% vs. 100.6% (48.7-403.2%; p=0.006. Systemic parameters assessment revealed significantly higher left cardiac work index in single-chamber group than dual-chamber group 4.9 kg.m/m² (2.8-7.6 kg.m/m² vs. 4.3 kg.m/m² (2.9-7.2 kg.m/m²; p=0.004. There was no significant difference on systemic vascular resistance in single-chamber compared to dual-chamber pacemaker. Single-chamber ventricular pacemaker provides similar stroke volume, cardiac output and left cardiac work, compared to dual-chamber pacemaker. A non-invasive hemodynamic measurement using thoracic electrical bioimpedance is feasible for permanent pacemaker outpatients. (Med J Indones 2008; 17: 25-32Keywords: Permanent pacemaker, single chamber, dual chamber, thoracic electrical bioimpedance, hemodynamic parameter

  12. APS Storage Ring vacuum chamber fabrication

    International Nuclear Information System (INIS)

    The 1104-m circumference Advanced Photon Source Storage Ring Vacuum System is composed of 240 individual sections, which are fabricated from a combination of aluminum extrusions and machined components. The vacuum chambers will have 3800 weld joints, each subject to strict vacuum requirements, as well as a variety of related design criteria. The vacuum criteria and chamber design are reviewed, including a discussion of the weld joint geometries. The critical fabrication process parameters for meeting the design requirements are discussed. The experiences of the prototype chamber fabrication program are presented. Finally, the required facilities preparation for construction activity is briefly described. 6 refs., 6 figs., 1 tab

  13. The KLOE drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Adinolfi, M.; Aloisio, A.; Ambrosino, F.; Andryakov, A.; Antonelli, A.; Antonelli, M.; Anulli, F.; Bacci, C.; Bankamp, A.; Barbiellini, G.; Bellini, F.; Bencivenni, G.; Bertolucci, S.; Bini, C.; Bloise, C.; Bocci, V.; Bossi, F.; Branchini, P.; Bulychjov, S.A.; Cabibbo, G.; Calcaterra, A.; Caloi, R.; Campana, P.; Capon, G.; Carboni, G.; Cardini, A.; Casarsa, M.; Cataldi, G.; Ceradini, F.; Cervelli, F.; Cevenini, F.; Chiefari, G.; Ciambrone, P.; Conetti, S.; Conticelli, S.; Lucia, E. De; Robertis, G. De; Sangro, R. De; Simone, P. De; Zorzi, G. De; Dell' Agnello, S.; Denig, A.; Domenico, A. Di; Donato, C. Di; Falco, S. Di; Doria, A.; Drago, E.; Elia, V.; Erriquez, O.; Farilla, A.; Felici, G.; Ferrari, A.; Ferrer, M.L.; Finocchiaro, G.; Forti, C.; Franceschi, A.; Franzini, P.; Gao, M.L.; Gatti, C.; Gauzzi, P.; Giovannella, S.; Golovatyuk, V.; Gorini, E.; Grancagnolo, F.; Grandegger, W.; Graziani, E.; Guarnaccia, P.; Hagel, U.V.; Han, H.G.; Han, S.W.; Huang, X.; Incagli, M.; Ingrosso, L.; Jang, Y.Y.; Kim, W.; Kluge, W.; Kulikov, V.; Lacava, F.; Lanfranchi, G.; Lee-Franzini, J.; Lomtadze, F.; Luisi, C.; Mao, C.S.; Martemianov, M.; Matsyuk, M.; Mei, W.; Merola, L.; Messi, R.; Miscetti, S.; Moalem, A.; Moccia, S.; Moulson, M.; Mueller, S.; Murtas, F.; Napolitano, M.; Nedosekin, A.; Panareo, M.; Pacciani, L.; Pages, P.; Palutan, M.; Paoluzi, L.; Pasqualucci, E.; Passalacqua, L.; Passaseo, M.; Passeri, A.; Patera, V.; Petrolo, E.; Petrucci, G.; Picca, D.; Pirozzi, G.; Pistillo, C.; Pollack, M.; Pontecorvo, L.; Primavera, M.; Ruggieri, F.; Santangelo, P.; Santovetti, E.; Saracino, G.; Schamberger, R.D.; Schwick, C.; Sciascia, B.; Sciubba, A.; Scuri, F.; Sfiligoi, I.; Shan, J.; Silano, P.; Spadaro, T.; Spagnolo, S.; Spiriti, E.; Stanescu, C.; Tong, G.L.; Tortora, L.; Valente, E.; Valente, P. E-mail: paolo.valente@lnf.infn.it; Valeriani, B.; Venanzoni, G.; Veneziano, S.; Wu, Y.; Xie, Y.G.; Zhao, P.P.; Zhou, Y

    2001-04-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K{sub L} produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm{sup 2} in size in the 12 innermost layers and 3x3 cm{sup 2} in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented.

  14. The KLOE drift chamber

    International Nuclear Information System (INIS)

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy KL produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm2 in size in the 12 innermost layers and 3x3 cm2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented

  15. Development of an accumulation-based system for cost-effective chamber measurements of inert trace gas fluxes

    DEFF Research Database (Denmark)

    Ambus, Per; Skiba, U.; Drewer, J.;

    2010-01-01

    As soil–atmosphere fluxes of greenhouse gases are characterized by high temporal fluctuations, frequent measurements in the range of hours to days need to be deployed, resulting in high analytical costs. We have therefore developed a new low-cost system that combines high-frequency automated...

  16. Automatic control system for measuring currents produced by ionization chambers; Automatizacao de um sistema de medidas de correntes produzidas por camaras de ionizacao e aplicacao na calibracao do {sup 18}F e {sup 153}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Brancaccio, Franco

    2002-07-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for {sup 18}F and {sup 153}Sm were obtained, making possible to determine activities of these radionuclides. (author)

  17. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  18. Monitored Drift Chambers in the ATLAS Detector

    CERN Multimedia

    Herten, G

    Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...

  19. Impact excited strain gage for multiwire chambers

    International Nuclear Information System (INIS)

    A method for measuring multiwire chamber tension by impact excitation of mechanical oscillations and measuring their periods is described. A flowsheet of an automated electron gaugeis presented; the gauge provides high efficiency and possibility for measurements under conditions of difficult availability of the multiwire chamber system. The range of tension measurements is 0.5-70 g for gilded tugsten wires of 20 μm in diameter and 60 cm length

  20. The OPAL jet chamber full scale prototype

    International Nuclear Information System (INIS)

    The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. Operating experience has been gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given. (orig.)

  1. Treatment delivery reproducibility of an helical tomotherapy system evaluated by using 2-D ionization chamber and imaging detector arrays

    International Nuclear Information System (INIS)

    The Tomotherapy Hi-Art system (HT) is a radiation therapy machine that integrate the delivery of intensity modulated radiation therapy (IMRT) in a helical fashion together with a real time computed tomography (CT) image-guided radiation therapy (IGRT). The radiation source (Linac, 6 MV) is collimated into a fan beam and modulated by means of a binary multileaf collimator (MLC). A xenon detector array, opposite the radiation source, allows a megavoltage-CT (MVCT) acquisition of patient images for set-up verification and collect exit dosimetry data during the treatment delivery. The HT treatment unit can in principle provide a treatment verification method called ''dose reconstruction'' that allows the daily treatment to be reconstructed in the form of delivered dose images. These delivered dose images could be compared to images of planned dose to determine if following treatments should be modified to correct for errors in completed treatments - a process called ''adaptive radiation therapy''. The combination of daily CT imaging and dose reconstruction capabilities could therefore allow an extremely high accuracy in treatment delivery process. Although this type of validation dosimetry is not yet available on current HT units, the acquisition system is increasingly used for dosimetry purposes as well as for imaging purposes

  2. Wire chamber conference

    International Nuclear Information System (INIS)

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  3. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  4. Drift chamber detectors

    International Nuclear Information System (INIS)

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  5. LEP vacuum chamber, prototype

    CERN Multimedia

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  6. Advanced photon source experience with vacuum chambers for insertion devices

    International Nuclear Information System (INIS)

    During the last five years, a new approach to the design and fabrication of extruded aluminum vacuum chambers for insertion devices was developed at the Advanced Photon Source (APS). With this approach, three different versions of the vacuum chamber, with vertical apertures of 12 mm, 8 mm, and 5 mm, were manufactured and tested. Twenty chambers were installed into the APS vacuum system. All have operated with beam, and 16 have been coupled with insertion devices. Two different vacuum chambers with vertical apertures of 16 mm and 11 mm were developed for the BESSY-II storage ring and 3 of 16 mm chambers were manufactured

  7. Measuring the sensitivity of a boron-lined ion chamber

    International Nuclear Information System (INIS)

    Boron-lined ion chambers are used to monitor external neutron flux from fissionable materials assembled at the Los Alamos Critical Assembly Experiment Facility. The sensitivity of these chambers must be measured periodically in order to detect changes in filling gas and to evaluate other factors that may affect chamber performance. We delineate a procedure to measure ion chamber response using a particular neutron source (239PuBe) in a particular moderating geometry of polyethylene. We also discuss use of the amplifier, high-voltage power supply, recorders, and scram circuits that comprise the complete ion chamber monitoring system

  8. Radiation Target Area Sample Environmental Chamber (RTASEC) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  9. Experimental work on drift chambers

    International Nuclear Information System (INIS)

    An experimental work made on drift chambers is described in two chapters. In the firt chapter we present the description of the experimental installation used, as well as some details on the data adquisition systems and the characteristics on three ways used for calibration proposes (cosmic muons, β radiation and test beam using SPS at CERN facilities). The second chapter describes the defferent prototypes studied. The experimental set up and the analysis are given. Some results are discussed. The magnetic field effect is also studied. (Author)

  10. Three chamber negative ion source

    International Nuclear Information System (INIS)

    A negative ion vessel is divided into an excitation chamber, a negative ionization chamber and an extraction chamber by two magnetic filters. Input means introduces neutral molecules into a first chamber where a first electron discharge means vibrationally excites the molecules which migrate to a second chamber. In the second chamber a second electron discharge means ionizes the molecules, producing negative ions which are extracted into or by a third chamber. A first magnetic filter prevents high energy electrons from entering the negative ionization chamber from the excitation chamber. A second magnetic filter prevents high energy electrons from entering the extraction chamber from the negative ionizing chamber. An extraction grid at the end of the negative ion vessel attracts negative ions into the third chamber and accelerates them. Another grid, located adjacent to the extraction grid, carries a small positive voltage in order to inhibit positive ions from migrating into the extraction chamber and contour the plasma potential. Additional electrons can be suppressed from the output flux using ExB forces provided by magnetic field means and the extractor grid electric potential

  11. Development of a vacuum control system for plasma welding chamber%等离子焊箱真空控制系统研制

    Institute of Scientific and Technical Information of China (English)

    张乃禄; 李洋; 许道玉; 李选锋; 刘中磊

    2012-01-01

    在钛及钛合金熔炼生产中,真空等离子焊接是电极制备的重要工序,而真空等离子焊接的真空度对铸锭的质量影响很大.针对真空等离子焊箱真空控制系统的工艺和控制要求,研制基于工控机+PLC(S7-300) +INFICON PCG410-S真空计的集散控制系统,实现了对真空泵组、电磁阀、真空压力和枪抽空进行实时监测与控制优化.生产实际应用表明,该系统在提高抽真空效率,降低漏率,确保高质量钛及钛合金电极生产方面效果显著,具有一定的应用前景.%In smelting titanium and its alloy, vacuum plasma welding is an important process for electrode preparation, and the vacuum degree influences the ingot quality greatly. According to the requirements of technology and control system of vacuum plasma welding chamber, the distributed control system was built based on IPC, PLC ( S7-300 ) and INFICON PCG410-S vacuum gauge, which realized real-time monitoring and control optimization of the vacuum pump, electromagnetic valve, vacuum pressure and vacuum-pumping of gun. The practical application indicates that the system play a good role in improving the efficiency of vacuum pumping, reducing the leakage rate, and ensuring the production of high quality of titanium and titanium alloy electrodes, which has certain application prospects.

  12. Scintillations in ionization chambers

    International Nuclear Information System (INIS)

    High purity Ar and mixtures of Ar with 1% CH4, 3% CH4, CO2 and N2, respectively, have been applied for fission fragment detection in a gridded ionization chamber. Gas scintillation has been observed simultaneously with a photomultiplier VALVO-XP 2041. Whereas all mixtures work equally well as an ionization gas, only Ar + 3% N2 shows a primary scintillation yield sufficient for fas timing. (orig.)

  13. Double chambered right ventricle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure.

  14. The GODDESS ionization chamber: developing robust windows

    Science.gov (United States)

    Blanchard, Rose; Baugher, Travis; Cizewski, Jolie; Pain, Steven; Ratkiewicz, Andrew; Goddess Collaboration

    2015-10-01

    Reaction studies of nuclei far from stability require high-efficiency arrays of detectors and the ability to identify beam-like particles, especially when the beam is a cocktail beam. The Gammasphere ORRUBA Dual Detectors for Experimental Structure Studies (GODDESS) is made up of the Oak Ridge-Rutgers University Barrel Array (ORRUBA) of silicon detectors for charged particles inside of the gamma-ray detector array Gammasphere. A high-rate ionization chamber is being developed to identify beam-like particles. Consisting of twenty-one alternating anode and cathode grids, the ionization chamber sits downstream of the target chamber and is used to measure the energy loss of recoiling ions. A critical component of the system is a thin and robust mylar window which serves to separate the gas-filled ionization chamber from the vacuum of the target chamber with minimal energy loss. After construction, windows were tested to assure that they would not break below the required pressure, causing harm to the wire grids. This presentation will summarize the status of the ionization chamber and the results of the first tests with beams. This work is supported in part by the U.S. Department of Energy and National Science Foundation.

  15. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  16. Numerical simulation of magma chamber dynamics.

    Science.gov (United States)

    Longo, Antonella; Papale, Paolo; Montagna, Chiara Paola; Vassalli, Melissa; Giudice, Salvatore; Cassioli, Andrea

    2010-05-01

    Magma chambers are characterized by periodic arrivals of deep magma batches that give origin to complex patterns of magma convection and mixing, and modify the distribution of physical quantities inside the chamber. We simulate the transient, 2D, multi-component homogeneous dynamics in geometrically complex dyke+chamber systems, by means of GALES, a finite element parallel C++ code solving mass, momentum and energy equations for multi-component homogeneous gas-liquid (± crystals) mixtures in compressible-to-incompressible flow conditions. Code validation analysis includes several cases from the classical engineering literature, corresponding to a variety of subsonic to supersonic gas-liquid flow regimes (see http://www.pi.ingv.it/~longo/gales/gales.html). The model allows specification of the composition of the different magmas in the domain, in terms of ten major oxides plus the two volatile species H2O and CO2. Gas-liquid thermodynamics are modeled by using the compositional dependent, non-ideal model in Papale et al. (Chem.. Geol., 2006). Magma properties are defined in terms of local pressure, temperature, and composition including volatiles. Several applications are performed within domains characterized by the presence of one or more magma chambers and one or more dykes, with different geometries and characteristic size from hundreds of m to several km. In most simulations an initial compositional interface is placed at the top of a feeding dyke, or at larger depth, with the deeper magma having a lower density as a consequence of larger volatile content. The numerical results show complex patterns of magma refilling in the chamber, with alternating phases of magma ingression and magma sinking from the chamber into the feeding dyke. Intense mixing takes place in feeding dykes, so that the new magma entering the chamber is always a mixture of the deep and the initially resident magma. Buoyant plume rise occurs through the formation of complex convective

  17. Construction and performance of the PHENIX pad chambers

    International Nuclear Information System (INIS)

    We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points along each track in the spectrometer arms at mid-rapidity and covers a total area of 88 m2. Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising 172 800 electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported

  18. Construction and performance of the PHENIX pad chambers

    Energy Technology Data Exchange (ETDEWEB)

    Adcox, K.; Ajitanand, J.; Alexander, J.; Barrette, J.; Belkin, R.; Borland, D.; Bryan, W.L.; Rietz, R. du; El Chenawi, K.; Cherlin, A.; Fellenstein, J.; Filimonov, K.; Fraenkel, Z.; Gan, D.; Garpman, S.; Gil, Y.; Greene, S.V.; Gustafsson, H.-A.; Holzmann, W.; Issah, M.; Jagadish, U.; Lacey, R.; Lauret, J.; Liccardi, W.; Mark, S.K.; Milan, J.; Miller, T.E.; Milov, A.; Mitchell, J.T.; Nilsson, P.; Nikkinen, L.; Nystrand, J.; O' Brien, E.; Oskarsson, A. E-mail: anders.oskarsson@kosufy.lu.se; Oesterman, L.; Otterlund, I.; Qi, Y.; Pasmantirer, B.; Pinkenburg, C.; Ravinovich, I.; Rosati, M.; Rose, A.; Silvermyr, D.; Sivertz, M.; Smith, M.C.; Starinsky, N.; Stenlund, E.; Teodorescu, O.; Tserruya, I.; Tydesjoe, H.; Xie, W.; Young, G.R.; Yurevich, V

    2003-02-01

    We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points along each track in the spectrometer arms at mid-rapidity and covers a total area of 88 m{sup 2}. Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising 172 800 electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported.

  19. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  20. Optimization of a closed-loop gas system for the operation of Resistive Plate Chambers at the Large Hadron Collider experiments

    Science.gov (United States)

    Capeans, M.; Glushkov, I.; Guida, R.; Hahn, F.; Haider, S.

    2012-01-01

    Resistive Plate Chambers (RPCs), thanks to their fast time resolution (˜1 ns), suitable space resolution (˜1 cm) and low production cost (˜50 €/m2), are widely employed for the muon trigger systems at the Large Hadron Collider (LHC). Their large detector volume (they cover a surface of about 4000 m2 equivalent to 16 m3 of gas volume both in ATLAS and CMS) and the use of a relatively expensive Freon-based gas mixture make a closed-loop gas circulation unavoidable. It has been observed that the return gas of RPCs operated in conditions similar to the difficult experimental background foreseen at LHC contains a large amount of impurities potentially dangerous for long-term operation. Several gas-cleaning agents are currently in use in order to avoid accumulation of impurities in the closed-loop circuits. We present the results of a systematic study characterizing each of these cleaning agents. During the test, several RPCs were operated at the CERN Gamma Irradiation Facility (GIF) in a high radiation environment in order to observe the production of typical impurities: mainly fluoride ions, molecules of the Freon group and hydrocarbons. The polluted return gas was sent to several cartridges, each containing a different cleaning agent. The effectiveness of each material was studied using gas chromatography and mass-spectrometry techniques. Results of this test have revealed an optimized configuration of filters that is now under long-term validation.Gas optimization studies are complemented with a finite element simulation of gas flow distribution in the RPCs, aiming at its eventual optimization in terms of distribution and flow rate.

  1. Optimization of a closed-loop gas system for the operation of Resistive Plate Chambers at the Large Hadron Collider experiments

    International Nuclear Information System (INIS)

    Resistive Plate Chambers (RPCs), thanks to their fast time resolution (∼1 ns), suitable space resolution (∼1 cm) and low production cost (∼50 €/m2), are widely employed for the muon trigger systems at the Large Hadron Collider (LHC). Their large detector volume (they cover a surface of about 4000 m2 equivalent to 16 m3 of gas volume both in ATLAS and CMS) and the use of a relatively expensive Freon-based gas mixture make a closed-loop gas circulation unavoidable. It has been observed that the return gas of RPCs operated in conditions similar to the difficult experimental background foreseen at LHC contains a large amount of impurities potentially dangerous for long-term operation. Several gas-cleaning agents are currently in use in order to avoid accumulation of impurities in the closed-loop circuits. We present the results of a systematic study characterizing each of these cleaning agents. During the test, several RPCs were operated at the CERN Gamma Irradiation Facility (GIF) in a high radiation environment in order to observe the production of typical impurities: mainly fluoride ions, molecules of the Freon group and hydrocarbons. The polluted return gas was sent to several cartridges, each containing a different cleaning agent. The effectiveness of each material was studied using gas chromatography and mass-spectrometry techniques. Results of this test have revealed an optimized configuration of filters that is now under long-term validation. Gas optimization studies are complemented with a finite element simulation of gas flow distribution in the RPCs, aiming at its eventual optimization in terms of distribution and flow rate.

  2. Review of wire chamber aging

    International Nuclear Information System (INIS)

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  3. Numerical solutions of differential equations of an ionization chamber

    International Nuclear Information System (INIS)

    A system of reduced differential equations generally valid for plane-parallel, cylindrical, and spherical ionization chambers filled with air, which is appropriate for numerical solution, has been derived. The system has been solved for all three geometries. The comparison of the calculated results of Armstrong and Tate, for plane-parallel ionization chambers, and Sprinkle and Tate, for spherical ionization chambers, with the present calculations has shown a good agreement. The calculated values for ionization chambers filled with CO2 were also in good agreement with the experimental data of Moriuchi et al (author)

  4. Propagation of the trip behavior in the VENUS vertex chamber

    International Nuclear Information System (INIS)

    The high voltage system of the VENUS vertex chamber occasionally trips by a discharge somewhere among cathode electrodes during data taking. This trip behavior induces often additional trips at other electrodes such as the skin and the grid electrodes in the vertex chamber. This propagation mechanism of trips is so complicated in this system related with multi-electrodes. Although the vertex chamber is already installed inside the VENUS detector and consequently the discharge is not able to observe directly, a trial to estimate the propagation has been done using only the information which appears around the trip circuits and the power supply of the vertex chamber. (author)

  5. Design of the CLIC Quadrupole Vacuum Chambers

    CERN Document Server

    Garion, C

    2010-01-01

    The Compact Linear Collider, under study, requires vacuum chambers with a very small aperture, of the order of 8 mm in diameter, and with a length up to around 2 m for the main beam quadrupoles. To keep the very tight geometrical tolerances on the quadrupoles, no bake out is allowed. The main issue is to reach UHV conditions (typically 10-9 mbar static pressure) in a system where the vacuum performance is driven by water outgassing. For this application, a thinwalled stainless steel vacuum chamber with two ante chambers equipped with NEG strips, is proposed. The mechanical design, especially the stability analysis, is shown. The key technologies of the prototype fabrication are given. Vacuum tests are carried out on the prototypes. The test set-up as well as the pumping system conditions are presented.

  6. Rapid-Cycling Bubble-Chamber, details

    CERN Multimedia

    1980-01-01

    Parts of the hydraulic expansion system of the Rapid-Cycling Bubble-Chamber (RCBC). RCBC was the largest of 3 rapid-cycling bubble-chambers (the others were LEBC and HOLEBC), used as target- and vertex-detectors within the European Hybrid Spectrometer (EHS) in the SPS North Area (EHN1). RCBC contained 250 l of liquid hydrogen and was located inside a 3 T superconducting magnet. It was designed for 30 expansions/s (100 times faster than BEBC), the system shown here allowed 50 expansions/s. RCBC operated from 1981 to 1983 for experiments NA21, NA22 and NA23 at a rate of 15 expansions/s, clocking up a total of over 4 million. In the rear, at left, is bearded Lucien Veillet; Augustin Didona is at the right. See also 8001009. The installation of the piston assembly in the RCBC chamber body is shown in the Annual Report 1980, p.65.

  7. Council Chamber exhibition

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    To complete the revamp of CERN’s Council Chamber, a new exhibition is being installed just in time for the June Council meetings.   Panels will showcase highlights of CERN’s history, using some of the content prepared for the exhibitions marking 50 years of the PS, which were displayed in the main building last November. The previous photo exhibition in the Council Chamber stopped at the 1970s. To avoid the new panels becoming quickly out of date, photos are grouped together around specific infrastructures, rather than following a classic time-line. “We have put the focus on the accelerators – the world-class facilities that CERN has been offering researchers over the years, from the well-known large colliders to the lesser-known smaller facilities,” says Emma Sanders, who worked on the content. The new exhibition will be featured in a future issue of the Bulletin with photos and an interview with Fabienne Marcastel, designer of the exhibit...

  8. Cardiac chamber scintiscanning

    International Nuclear Information System (INIS)

    The two methods of cardiac chamber scintiscanning, i.e. 'first pass' and 'ECG-triggered' examinations, are explained and compared. Two tables indicate the most significant radiation doses of the applied radio tracers, i.e. 99m-Tc-pertechnetate and 99m-Tc-HSA, to which a patient is exposed. These averaged values are calculated from various data given in specialised literature. On the basis of data given in literature, an effective half-life of approximately 5 hours in the intravascular space was calculated for the erythrocytes labelled with technetium 99m. On this basis, the radiation doses for the patients due to 99m-Tc-labelled erythrocytes are estimated. The advantages and disadvantages of the two methods applied for cardiac chamber scintiscanning are put into contrast and compared with the advantages and disadvantages of the quantitative X-ray cardiography of the left heart. The still existing problems connected with the assessment of ECG-triggered images are discussed in detail. The author performed investigations of his own, which concerned the above-mentioned problems. (orig./MG)

  9. Metal release in a stainless steel pulsed electric field (PEF) system Part II. The treatment of orange juice; related to legislation and treatment chamber lifetime

    NARCIS (Netherlands)

    Roodenburg, B.; Morren, J.; Berg, H.E.; Haan, S.W.H.de

    2005-01-01

    In the last decennia, there is an increasing interest in pulsed electric field (PEF) treatment. The product is often treated in a continuous flow treatment chamber with stainless steel electrodes and exposed to short pulsed electric fields, typically 2-4 kV mm-1 during 1-10 μs. Due to direct contact

  10. CFD Simulation Evaluation for Flow Distribution of the Closed Chamber

    OpenAIRE

    Hong Bin; Wang Hongmei

    2016-01-01

    Taking a closed chamber flow field as object, this paper establishes the 3D model of the Closed Chamber. With the conclusion of flow distribution and gasoline vapor concentration distribution of the Closed Chamber reached via the CFD software of Fluent and experiment research, this paper analyzes the flow distribution and concentration distribution of gasoline vapor. Several improvement projects are proposed, such as improving the wind circulation system to optimize the indoor gas concentrati...

  11. Coke Oven Facing New Century——Modularized Single Chamber System%面向新世纪的焦炉——模块化的单室焦炉

    Institute of Scientific and Technical Information of China (English)

    蔡承

    2001-01-01

    模块化的单室炉系统能实现焦炉的超大型化和高效化并能实现预热煤炼焦,是一项值得关注的炼焦新技术。%Modularized Single Chamber System (SCS) is the new coking technology which makes the capacity of oven super- large and efficiency super-high and also realizes coking by using of preheated coal.

  12. Proportional chambers for the Σ installation

    International Nuclear Information System (INIS)

    Two types of proportional chambers used in experiments with SIGMA set are considered. The main parameters of detecting electronics, high-voltage, low-voltage and gas supplies are presented. The first type chambers consist of the round or square frames of sheet foiled glass-cloth-base laminate, on which surface electrode lands and joints between them are applied by photographic printing. The second type chamber electrodes are also made of the sheet foiled glass-cloth-base laminate as strips arranged at the ends of two rectangular metallic profiles. The chamber sensitive regions vary from 64x64 mm to 768x2500 mm. The chambers are used for more than 15 years in different experiments, such as determination of elastic scattering, study of J/ψ and ψ' particle production, search for charm particles in hadron interactions, measuring the change of π--meson polarizability, study of μ+μ-π- system production. The experience of past years manifested their high efficiency and reliability

  13. Experiments with a spark chamber

    International Nuclear Information System (INIS)

    The authors constructed an experimental spark chamber with a useable volume of 7 x 7 x 5 cm having six parallel 2-mm thick stainless steel plates. The distance between each plate is 8 mm. The chamber is filled with neon under a pressure of one atmosphere. On applying a pulse of about 10 keV on the plates immediately after the passage of a charged particle through the chamber, sparks form along the trajectory of the particle and may easily be photographed. The chamber was first used with cosmic ray μ mesons and then put into the π-meson beam of the SATURN synchrocyclotron. The efficiency of the chamber as a function of voltage and retardation of the applied electric pulse and the dead time are given. The first results obtained with a chamber of 10-litre volume are also presented. (author)

  14. Posing the first LEAR vacuum chamber

    CERN Multimedia

    1982-01-01

    The photo shows one of the four bending magnets of LEAR. They were of C-type with the opening ('mouth') to the outside of the ring (yoke to the inside). Last preparations are made before the vacuum chamber is slid through the mouth into the magnet. Stochastic cooling pickups/kickers were installed inside the chamber. One can distinguish a large number of feed-throughs on the chamber (leading to the pickup/kicker gaps). The free space in the middle of the block was left to offer room for an internal target in the magnet. This possibility was never exploited. Instead it is used here, to accommodate a pumping port for the high vacuum system. Michel Chanel (left) and Pierre Lefevre admire the mechanics at work.

  15. Multi-chamber ionization detector

    International Nuclear Information System (INIS)

    For the detector a single beta ionization source and a double- or three-chamber set-up is used, the chambers being designed in the shape of a truncated cone and facing each other with their bases. The source can be positioned with respect to the common center or modal electrode, the adjustment of the ionization in each chamber this becoming easier. The center or modal electrode also can be adjusted with respect to the source. (DG)

  16. Leukoreduction system chambers provide a valuable source of functional monocytes for the monocyte activation test by comparison with internationally validated methods.

    Science.gov (United States)

    Nordgren, Ida Karin

    2016-01-01

    Despite being added to the European Pharmacopoeia in 2010 and strongly supported by the European directive enforcing the "3R's" - Replace, Reduce and Refine, uptake of the monocyte activation test (MAT) in preference over the rabbit pyrogen test for the detection of pyrogens has been limited. This has been attributed to the difficulty in sourcing human monocytes due to the necessity of phlebotomy. This study has attempted to address this issue by evaluating cryopreserved peripheral blood mononuclear cells (PBMCs) isolated from leukoreduction system chambers (LRSCs), a readily available by-product of platelet apheresis, as a source of monocytes for the MAT. Validation was performed by direct comparison with the two most commonly employed primary monocyte sources: fresh whole blood (WB) and PBMCs from fresh blood, assessing their ability to detect a panel of toll-like receptor (TLR) ligands including Pam3CSK4, Lipoteichoic acid, Peptidoglycan, Poly(I:C) and Flagellin, as well as two different endotoxin sources, with IL-1β and IL-6 as the readouts. All three cell sources were able to detect the pyrogens included in the study with comparable sensitivities, with the exception of TLR3 ligand Poly(I:C). The WB assay produced quantifiable, but significantly lower cytokine levels with every pyrogen tested than either of the PBMCs sources used. LRSCs provided an ample and convenient source of PBMCs which were successfully cryopreserved, providing cell banks for each donor, shown to maintain stability for at least a year. The use of cryopreserved PBMCs reduced the time and effort required to set up an assay, and the availability of single donor cell banks will allow investigations into assay variables in the absence of inter-donor variability. Significantly higher sensitivity to Pam3CSK4 was observed with a proportion of donors. This was found to correlate to single nucleotide polymorphisms rs4833095 and rs5743618 of TLR1. This evidence, along with the wide range of other

  17. Longimicrobium terrae gen. nov., sp. nov., an oligotrophic bacterium of the under-represented phylum Gemmatimonadetes isolated through a system of miniaturized diffusion chambers.

    Science.gov (United States)

    Pascual, Javier; García-López, Marina; Bills, Gerald F; Genilloud, Olga

    2016-05-01

    A novel chemo-organoheterotroph bacterium, strain CB-286315T, was isolated from a Mediterranean forest soil sampled at the Sierra de Tejeda, Almijara and Alhama Natural Park, Spain, by using the diffusion sandwich system, a device with 384 miniature diffusion chambers. 16S rRNA gene sequence analyses identified the isolate as a member of the under-represented phylum Gemmatimonadetes, where 'Gemmatirosa kalamazoonensis' KBS708, Gemmatimonas aurantiaca T-27T and Gemmatimonas phototrophica AP64T were the closest relatives, with respective similarities of 84.4, 83.6 and 83.3 %. Strain CB-286315T was characterized as a Gram-negative, non-motile, short to long rod-shaped bacterium. Occasionally, some cells attained an unusual length, up to 35-40 μm. The strain showed positive responses for catalase and cytochrome-c oxidase and division by binary fission, and exhibited an aerobic metabolism, showing optimal growth under normal atmospheric conditions. Strain CB-286315T was also able to grow under micro-oxic atmospheres, but not under anoxic conditions. The strain is a slowly growing bacterium able to grow under low nutrient concentrations. Major fatty acids included iso-C17 : 1ω9c, summed feature 3 (C16 : 1ω7c and/or iso-C15 : 0 2-OH), C16 : 0 and iso-C17 : 0. The major polar lipids were phosphatidylglycerol, phosphatidylethanolamine, phosphatidylcholine, two unidentified glycolipids and three phospholipids. The major isoprenoid quinone was MK-8 and the diagnostic diamino acid was meso-diaminopimelic acid. The DNA G+C content was 67.0 mol%. Based on a polyphasic taxonomic characterization, strain CB-286315T represents a novel genus and species, Longimicrobium terrae gen. nov., sp. nov., within the phylum Gemmatimonadetes. The type strain of Longimicrobium terrae is strain CB-286315T ( = DSM 29007T = CECT 8660T). In order to classify the novel taxon within the existing taxonomic framework, the family Longimicrobiaceae fam. nov., order

  18. Induction of peroxisome proliferation in hepatocytes transplanted into the anterior chamber of the eye. A model system for the evaluation of xenobiotic-induced effects.

    OpenAIRE

    Rao, M S; THORGEIRSSON, S.; Reddy, M. K.; Lalwani, N. D.; Evarts, R. E.; Usman, M I; Singh, B.; Reddy, J K

    1986-01-01

    The effect of two hypolipidemic peroxisome proliferators, ciprofibrate and di(2-ethylhexyl)phthalate (DEHP), on hepatocytes transplanted into the anterior chamber of the eye was examined. Young male F-344 rats transplanted with dissociated hepatocytes were fed either a control diet or a diet containing 0.025% ciprofibrate or 2% DEHP. After 4-5 weeks of treatment, all rats were sacrificed and the transplanted liver cells and portions of homotopic liver were processed for light and electron mic...

  19. 高低温试验箱制冷系统最佳制冷剂充注量研究%Research on Best Refrigerant Charges in Refrigeration System of High and Low Temperature Test Chamber

    Institute of Scientific and Technical Information of China (English)

    李佳; 张华

    2015-01-01

    高低温试验箱适用于工业产品高、低温的可靠性试验.本文以一高低温试验箱为对象,在完成制冷系统设计,包括制冷剂选择、制冷系统部件选型等工作的基础上,对高低温试验箱进行制冷剂充注量实验,得到试验箱在最佳运行状态下的最佳充注量.%High and low temperature test chamber is suitable for the reliability test at high and low temperatures for industrial products. The research object is a high and low temperature test chamber. After completing the design of the refrigeration system, including the choose of refrigerant and the selection of the system components, the refrigerant charge experiments were processed and the optimal refrigerant charge for the chamber at the best operation state was obtained.

  20. 救生舱舱门空气幕系统优化设计与试验分析%Optimum design and experimental analysis of air curtain system at the cabin door of refuge chamber

    Institute of Scientific and Technical Information of China (English)

    刘俊利; 霍佳伟; 靳宇辉

    2012-01-01

    为采用空气幕阻隔矿用救生舱舱外有害气体,利用数值模拟技术建立了二维舱门空气幕模型,通过对不同的空气幕喷口宽度、送风角度及送风速度下的气幕流场进行分析,对有限气源下空气幕系统进行优化设计,通过试验和数值模拟分析,验证了有限气源下空气幕系统设计的合理性.该研究成果已成功应用于"KJYY-12/96"型矿用紧急救生舱.%To solve the closed performance problem of air curtain flow field at the cabin door of a coal mine refuge chamber,a two-dimensional chamber air curtain model was established with numerical simulation technology.The air curtain flow field with air curtain outlet width,air velocity and air flow angle was numerically simulated through changing amount parameters of the mathematical simulation model,and the air curtain system under limited air source was proposed.With experimental data and numerical simulated result analyzed and compared,the reasonable design technical parameters were obtained.At present,the air curtain system under limited air source of coal a mine refuge chamber was used successfully in several actual projects of KJYY-12/96 coal mine refuge chamber.

  1. Mycocardial perfusion scintigraphy using a new technique, the mesh chamber

    International Nuclear Information System (INIS)

    The 10cm x 10cm chamber has been used in conjunction with a new reconstruction algorithm. Ongoing investigations are testing system performance, including three-dimensional resolution and contrast ratio for various objects. The chambers have had some reliability problems. 30 references, 7 figures

  2. The muon chambers take centre stage at CMS

    CERN Multimedia

    2003-01-01

    The CMS muon chambers are now starting to arrive at CERN in significant numbers. All in all, the muon system of the CMS detector will comprise some 1400 of these chambers. Twenty percent of those for the endcaps have already been installed, while the assembly of those for the barrel will start in December.

  3. Conceptual design study of the hylife lithium waterfall laser fusion chamber. FY 1978 annual report to Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Conceptual design studies of the target chamber defined the general configuration and dimensions of the chamber and the inlet plenum, orifice plate, and nozzle plate concepts required to generate the desired lithium jet fall. Preliminary studies were performed of the target chamber interfaces with the liquid lithium supply system, the laser system, the pellet injection system, and the target chamber mounting and support system. Target chamber environmental effects resulting from typical thermonuclear burns were evaluated. The outlet region of the target chamber was outlined conceptually, and preliminary design considerations were given to the annular graphite reflector regions of the target chamber and the associated liquid lithium coolant passages

  4. Ion chamber based neutron detectors

    Science.gov (United States)

    Derzon, Mark S; Galambos, Paul C; Renzi, Ronald F

    2014-12-16

    A neutron detector with monolithically integrated readout circuitry, including: a bonded semiconductor die; an ion chamber formed in the bonded semiconductor die; a first electrode and a second electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; and the readout circuitry which is electrically coupled to the first and second electrodes. The bonded semiconductor die includes an etched semiconductor substrate bonded to an active semiconductor substrate. The readout circuitry is formed in a portion of the active semiconductor substrate. The ion chamber has a substantially planar first surface on which the first electrode is formed and a substantially planar second surface, parallel to the first surface, on which the second electrode is formed. The distance between the first electrode and the second electrode may be equal to or less than the 50% attenuation length for neutrons in the neutron absorbing material filling the ion chamber.

  5. Calculation of reactivities using ionization chamber currents with different sets of kinetic parameters for reduced scram system efficiency in the VVER-1000 of the third unit of the Kalinin nuclear power plant at the stage of physical start-up

    International Nuclear Information System (INIS)

    The effectiveness of the VVER-1000 reactor scram system is analyzed using ionization chamber currents with different sets of kinetic parameters with allowance for the isotopic composition in the calculation of these parameters. The most “correct, aesthetically acceptable” results are obtained using the eight-group constants of the ROSFOND (BNAB-RF) library. The difference between the maximum and minimum values of the scram system effectiveness calculated with different sets of kinetic parameters slightly exceeds 2β. The problems of introducing corrections due to spatial effects are not considered in this study.

  6. Development of and horizontal seams wining system by means of galleries and chambers; Demostracion de un Sistema de Explotacion de Capas Horizontales por el Metodo de Pilares y Galerias Trazadas Integramente con Maquinas de Ataque Puntual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The project Development of an horizontal seams wining system by means of galleries and chambers aimed on the solution of a mining problem kept unresolved during the last 35 years in Carrasconte mine, owned by the society Minero Siderurgica de Ponferrada, in the coal yield of Villablino, Leon, Spain. The problem was a horizontal seam, with a width from 2,5 to 3,5 m, with two specific characteristics; one, roof and floor extremely rigid, with a 30 m sandstone stratum by roof that practically could highly restrict the long wall face conventional system, and the other, an intercalation of shale with a width of 1,2 m and a hardness of near 400 kg/cm2 that required a suitable winning system. By means of investigation with galleries carried out by continuous miners the real width of shale intercalation was stated, an then suitable systems adopted as this width varied. So, short wall faces in areas with minimum shale were disposed, and in t areas with maximum shale width, two long wall faces each one in each different vein were designed. At the end, the borders of reserves were recovered by the conventional system of galleries and chambers. This development project has allowed to recover more than a million tons in three years by systems suitable to the different conditions of the seam. (Author)

  7. 具有USB和RS232接口的气室调节监控系统%Gas chamber regulation monitoring system with USB and RS232 interface

    Institute of Scientific and Technical Information of China (English)

    王全会; 郑丰隆; 丁俊峰; 齐俊清; 刘杰

    2011-01-01

    为准确研究环境因素对农作物的生长产生的影响,设计了一种可以自动调节气室CO2浓度的检测控制系统.该系统采用12846液晶实时显示数据,根据人工设定气体含量参数,自动控制CO2发生器维持气室的气体含量.研究结果表明,该系统可对气室内氧气、二氧化碳和发生器内压力数据进行采集与控制,可实现内部存储、U盘读取和直接与PC机通信,以及在PC机上显示、存储数据等功能.%In order to accurately research environment factors on the effects of crop growth, a kind of the detection and control system of gas chamber automatically adjusting the CO2 concentration was designed. The system can collect and control the data of oxygen, carbon dioxide in gas chamber and the pressure of the carbon dioxide generator. And the system can real-timely display gas data with a 12846 LCD. According to artificially setting gas content parameters, the system can automatic control CO2 generator of gas content to maintain the gas chamber. Results show that the system can store data and read by U-disk directly. When communicating with PC, it can display and store data in PC.

  8. Bubble Chambers for Experiments in Nuclear Astrophysics

    OpenAIRE

    DiGiovine, B.; Henderson, D.; Holt, R. J.; Rehm, K. E.; Raut, R.; Robinson, A.; Sonnenschein, A.; Rusev, G.; A.P. Tonchev; Ugalde, C.

    2015-01-01

    A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning...

  9. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  10. Cyclically controlled welding purge chamber

    Science.gov (United States)

    Gallagher, Robert L. (Inventor)

    1996-01-01

    An arrangement for butt-welding cylindrical sections of large, thin-wall tanks includes a rotatable mandrel with side-by-side sets of radial position adjusters. Each set of adjusters bears on one of the tank sections adjacent the seam, to prevent the sections from sagging out-of-round. The mandrel rotates relative to the welder, so that a continuous seam is formed. A purge chamber is fixed in position behind the seam at the weld head, and is flushed with inert gas. The purge chamber includes a two-sided structure which is contiguous with the cylindrical sections and a circumferential vane to form an open-ended tube-like structure, through which the radial position adjusters pass as the mandrel and cylindrical workpiece sections rotate. The tube-like structure is formed into a chamber by a plurality of movable gates which are controlled to maintain a seal while allowing adjusters to progress through the purge chamber.

  11. Performance of ionization chambers in X radiation beams, radioprotection level

    International Nuclear Information System (INIS)

    Narrow beams, radioprotection level, were implanted in an X ray system, based on ISO 4037-1, as recommended by IAEA (SRS 16). Energy dependency tests were carried out and short-term stability in ionization chambers for use in radiation protection of trademark Physikalisch-Technische Werkstaetten (PTW), 32002 and 23361 models. The ionization chambers were studied with regard to short-term stability within the program of quality control of the laboratory, with a 90Sr + 90Y. The results of the short-term stability test were compared with the recommendations of IEC 60731, respect to dosemeters used in radiotherapy, since this standard presents the more restrictive limits with regard to the behaviour of ionization chambers. All cameras showed results within the limits recommended by this standard. With respect to the energy dependency of the response, the model Chamber 32002 presented a maximum dependence of only 2.7%, and the model Chamber 23361, 4.5%

  12. Limited streamer chamber testing and quality evaluation in ASTRA

    International Nuclear Information System (INIS)

    Limited streamer chambers are extensively used for high-energy and nuclear physics experiments in accelerator and underground laboratories. The tracking system of LVD, an underground experiment to study muons and nutrino astronomy, will use roughly 15000 limited streamer chambers and 100000 external pickup strips with digital readout electronics. In the article the different aspects of chamber operation that serve to establish a testing procedure and to define acceptance criteria for selecting reliable and long-life devices, are discussed. The procedures and the results obtained from a long-term test to evaluate streamer chamber quality, based upon a sample of 2900 items, are described. The selection tests and the long-term observations have been performed in the ASTRA laboratory, established at the Laboratori Nazionali di Frascati to carry out quality control procedures for streamer chambers on a large scale and in a controlled environment

  13. He leak testing of Indus-2 dipole vacuum chambers

    International Nuclear Information System (INIS)

    Full text: Centre for Advanced Technology is developing its second synchrotron radiation source INDUS-2 which is a 2.5 GeV electron storage ring. Dipole vacuum chambers are the vital components of Indus-2 vacuum system. Each of these chambers is approx. 3.6 m long and 0.67 m wide with 24 nos. of ports of various sizes. The dipole chambers were made by machining two halves and they are then lip welded together. The dipole chamber has approx. 14 m of total weld length and it was leak tested for leak tightness of the order of 10-10 mbar 1/s. Helium mass spectrometer leak detector (HMSLD) was utilized for the leak testing. Subsequently the leaks of various orders in welding joints were repaired and leak tightness achieved. This paper describes the experiences during leak testing of 20 nos. of aluminum dipole chambers for INDUS-2

  14. BEBC Big European Bubble Chamber

    CERN Multimedia

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  15. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    CERN Document Server

    Ahmed, M W; Bertovic, I; Bjoraker, J; Chrien, R; Cui, X; Dehnhard, D; Empl, A; Furic, M; Gerald, J; Gill, R; Hungerford, E V; Juengst, H; Lan, K J; Liu, J H; Morris, C L; O'donnell, J M; Peng, J C; Petkovic, T; Pile, P; Planinic, M; Riedel, C M; Rusek, A; Sutter, R; Tang, L; Thiessen, H A; Youn, M; Zeps, V

    2001-01-01

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were sigma sub X approx 0.454 mm and sigma sub Y approx 1.180 mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment.

  16. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    International Nuclear Information System (INIS)

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were σX∼0.454 mm and σY∼1.180 mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment

  17. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    International Nuclear Information System (INIS)

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were sigmaX∼0.454mm and sigmaY∼1.180mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment

  18. Analysis of the internal temperature of the combustion chamber of a compact system of co-generation; Analise das temperaturas internas da camara de combustao de um sistema compacto de co-geracao

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Joao B.F. [Universidade de Fortaleza (UNIFOR), CE (Brazil)], email: furlan@unifor.br; Couto, Heraldo S. [Instituto Nacional de Pesquisas Espaciais (INPE), Cachoeira Paulista, SP (Brazil)], email: heraldo@lcp.inpe.br; Holanda, Carlos A.M. de [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Dept. de Engenharia Metalurgica e de Materiais], email: almir@metalmat.ufc.br

    2008-07-01

    Nowadays, the energy deficit represents one of the biggest governmental challenges, since there is still a great number of communities living in areas without electricity energy; and thus without access to electro-electronic equipment such as television, refrigerators, computers. The main focus of this work is to present the possibility of electricity energy generation in conjunction with the frozen or hot water production in for places without electricity transmission nets or even any type of alternative power plants. The system is based on the standard air cycle called Brayton cycle composed of a turbo-compressor model 4LGZ from BorgWarner, a combustion chamber, a power turbine, a heat exchanger, a water-ammonia chiller, a 5.0 kV A generator, and a command panel for automation and distribution of energy. This system that uses natural gas or LPG, will supply electric energy from the generator, hot water from the heat exchange with the gases of combustion, and water frozen from chiller using as the hot source the gases proceeding from the power system. The prototype is already being tested and the first results obtained are excellent. In this paper, we analyze the internal combustion chamber temperatures. (author)

  19. Anterior chamber depth during hemodialysis

    Directory of Open Access Journals (Sweden)

    Gracitelli CPB

    2013-08-01

    Full Text Available Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241. We observed a significantly decreased anterior chamber depth (P = 0.002 during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma

  20. Air ionization wire plane chamber

    International Nuclear Information System (INIS)

    Radiation Measurement for protection level instrumentation requires large number of detectors. Since the number is large, the detector should be cost effective and yet should have good sensitivity. Gas detectors with presently available microelectronics and signal processing capabilities opened a new era in radiation monitoring. Present paper describes the use of air filled multi anode grid planes as detector for alpha detection. Due to multiple anode wire planes, the charge collection efficiency of the air ionization chamber is higher as compared to conventional ionization chamber. The signal from this Wire Plane Chamber (WPC) has a faster and narrower pulse shape as compared to conventional two-electrode chamber of similar dimensions. The reduction in capacitance also improves the signal to noise ratio so that air can be used as the ionization medium without any special cleaning procedure etc and it may be possible to use even engineering plastic as the structural material for the chamber. The paper gives the results obtained so far with this air ionization chamber. (author)

  1. Technical Design Study for the PANDA Time Projection Chamber

    CERN Document Server

    Ball, M; Dørheim, S; Höppner, C; Ketzer, B; Konorov, I; Neubert, S; Paul, S; Rauch, J; Uhl, S; Vandenbroucke, M; Berger, M; Berger-Chen, J -C; Cusanno, F; Fabbietti, L; Münzer, R; Arora, R; Frühauf, J; Kiš, M; Leifels, Y; Kleipa, V; Hehner, J; Kunkel, J; Kurz, N; Peters, K; Risch, H; Schmidt, C J; Schmitt, L; Schwab, S; Soyk, D; Voss, B; Weinert, J; Beck, R; Kaiser, D; Lang, M; Schmitz, R; Walther, D; Bühler, P; Müllner, P; Zmeskal, J; Hermann, N

    2012-01-01

    This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.

  2. Improved Rhenium Thrust Chambers for In-Space Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Radiation-cooled, bipropellant thrust chambers are being considered for the ascent/descent engines and reaction control systems (RCS) for future NASA missions such...

  3. Improved Rhenium Thrust Chambers for In-Space Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Radiation-cooled, bipropellant thrust chambers are being considered for the ascent/descent engines and reaction control systems for NASA missions such as Mars...

  4. Tracking simulation and wire chamber requirements for the SSC

    International Nuclear Information System (INIS)

    Limitations placed on wire chambers by radiation damage and rate requirements in the SSC environment are reviewed. Possible conceptual designs for wire chamber tracking systems which meet these requirements are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given. 16 refs., 16 figs., 2 tabs

  5. Tracking simulation and wire chamber requirements for the SSC

    International Nuclear Information System (INIS)

    In this paper limitations placed on wire chambers by radiation damage and rate requirements in the SSC environment are reviewed. Possible conceptual designs for wire chamber tracking systems which meet these requirements are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given

  6. Micromachined filter-chamber array with passive valves for biochemical assays on beads

    NARCIS (Netherlands)

    Lichtenberg, Jan; Verpoorte, Elisabeth; De Rooij, Nico F.

    2001-01-01

    The filter-chamber array presented here enables a real-time parallel analysis of three different samples on beads in a volume of 3 nL, on a 1 cm2chip. The filter-chamber array is a system containing three filter-chambers, three passive valves at the inlet channels and a common outlet. The design ena

  7. Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer

    CERN Document Server

    Bauer, F; Kortner, O; Kroha, H; Manz, A; Mohrdieck, S; Richter, R; Zhuravlov, V

    2016-01-01

    Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring system demonstrate that the requirements for the mechanical precision of the chambers are fulfilled.

  8. Seasonal Dynamics of N2O and CO2 Emissions from a Corn Production System measured with the Eddy covariance and Chamber techniques

    Science.gov (United States)

    Iwuozo, S. A.; Hui, D.; Dennis, S.

    2013-12-01

    Agricultural Practices play a major role in the global fluxes of the greenhouse gases carbon dioxide, nitrous oxide, and methane. The use of fertilizer in Corn production has generated concerns about its contribution to global climate change. Thus, farmers and others concerned have become interested in more efficient fertilization management practice and reduced greenhouse gas emissions. To understand best management practices, in the 2012 and 2013 corn growing seasons, field experiments was conducted at Tennessee State University Agricultural Research and Demonstration Center in Nashville, TN. The study examines the seasonal variations of (N2O) and (CO2) emissions from soil as a function of six treatment that include inorganic nitrogen fertilizer, chicken litter and biochar application. The combinations were: regular URAN 32-0-0 liquid fertilizer (2 times) no till, regular URAN 32-0-0 liquid fertilizer (2 times) conventional till, multiple URAN applications (4 times) no till, Denitrification inhibitor with regular URAN application in no till, chicken litter with regular URAN application no till and URAN application with biochar in no tilled plots. Each treatment was replicated 6 times. N2O and CO2 emissions were measured using a closed chamber method after rainfall event(s), fertilizer applications or every two weeks whichever was shorter. Corresponding soil NH4+-N and NO3--N, soil temperature and moisture were also measured during gas sampling. Plant physiological and growth parameters were measured as appropriate and meteorological records were kept. N2O flux was also continuously measured in a commercial corn field using the eddy covariance (EC) technique fitted with a fast response N2O analyzer to check the N2O emissions at the large scale and compare it to the chamber method. Results obtained with the EC technique were comparable with the chamber methods. Preliminary data indicate that N2O and CO2 fluxes were significantly influenced by the agricultural

  9. Herds of methane chambers grazing bubbles

    Science.gov (United States)

    Grinham, Alistair; Dunbabin, Matthew

    2014-05-01

    Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique

  10. HYLIFE-II reactor chamber mechanical design

    International Nuclear Information System (INIS)

    Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams are used for shielding and blast protection. The system is designed for an 8 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (20 m/s) salt streams and also recover up to half of the dynamic head

  11. Emulsion Chamber Technology Experiment (ECT)

    Science.gov (United States)

    Gregory, John C.; Takahashi, Yoshiyuki

    1996-01-01

    The experimental objective of Emulsion Chamber Technology (ECT) was to develop space-borne emulsion chamber technology so that cosmic rays and nuclear interactions may subsequently be studied at extremely high energies with long exposures in space. A small emulsion chamber was built and flown on flight STS-62 of the Columbia in March 1994. Analysis of the several hundred layers of radiation-sensitive material has shown excellent post-flight condition and suitability for cosmic ray physics analysis at much longer exposures. Temperature control of the stack was 20 +/-1 C throughout the active control period and no significant deviations of temperature or pressure in the chamber were observed over the entire mission operations period. The unfortunate flight attitude of the orbiter (almost 90% Earth viewing) prevented any significant number of heavy particles (Z greater than or equal to 10) reaching the stack and the inverted flow of shower particles in the calorimeter has not allowed evaluation of absolute primary cosmic ray-detection efficiency nor of the practical time limits of useful exposure of these calorimeters in space to the level of detail originally planned. Nevertheless, analysis of the observed backgrounds and quality of the processed photographic and plastic materials after the flight show that productive exposures of emulsion chambers are feasible in low orbit for periods of up to one year or longer. The engineering approaches taken in the ECT program were proven effective and no major environmental obstacles to prolonged flight are evident.

  12. An Efficient, FPGA-Based, Cluster Detection Algorithm Implementation for a Strip Detector Readout System in a Time Projection Chamber Polarimeter

    Science.gov (United States)

    Gregory, Kyle J.; Hill, Joanne E. (Editor); Black, J. Kevin; Baumgartner, Wayne H.; Jahoda, Keith

    2016-01-01

    A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photoelectron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

  13. CP violation in the B0 - B0- system with the CMS detector at the LHC and study of microstrip gas chambers

    International Nuclear Information System (INIS)

    This thesis has been performed for the CMS project at the LHC, the proton-proton collider at CERN, whose first data taking is foreseen for the years 2004-2005. This work is divided in two parts. The first part includes a general study about low energy electron identification using the very fine granularity and the high resolution of the electromagnetic calorimeter of CMS. The efficiency of this algorithm is estimated to be about 60% and the hadron rejection factor is about 400. These identified electrons can be used for the B hadron tagging as well as for the reconstruction of the semi-inclusive decay Bd0 → J/ψ (→e+e-) + X. The new sensitivities of the CMS detector to the angles α and β of the CKM unitarity triangle with this new possibilities and new proton structure functions are: δ(sin(2α)) = 0.06 (+0.018-0.014) δ(sin(2β)) = 0.053 (+0.017-0.012). This results are comparable to what is expected for the dedicated B-Physics experiments. The second part concerns the development of a new type of microstrip gas chambers (MGC) where the anodes are separated from the cathode plane by a few microns. This geometry allows a fast charge collection (about 10 ns), gain values of more than 3000 and an energy resolution of 20% for the peek of a 55Fe source. (author)

  14. An efficient, FPGA-based, cluster detection algorithm implementation for a strip detector readout system in a Time Projection Chamber polarimeter

    Science.gov (United States)

    Gregory, Kyle J.; Hill, Joanne E.; Black, J. Kevin; Baumgartner, Wayne H.; Jahoda, Keith

    2016-05-01

    A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photo- electron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

  15. Cryogenic Chamber for Servo-Hydraulic Materials Testing

    Science.gov (United States)

    Francis, John J.; Tuttle, James

    2009-01-01

    A compact cryogenic test chamber can be cooled to approximately 5 to 6 Kelvin for materials testing. The system includes a temperature controller and multiple sensors to measure specimen temperature at different locations. The testing chamber provides a fast and easy method to perform materials testing at lower than liquid nitrogen temperature (77 K). The purpose of the chamber is to cool a composite lap shear specimen to approximately 20 K so that tensile test force and displacement data may be acquired at this cryogenic temperature range.

  16. HF production in CMS-Resistive Plate Chambers

    International Nuclear Information System (INIS)

    The formation of highly reactive compounds in the gas mixture during Resistive Plate Chambers (RPCs) operation at the CERN Gamma Irradiation Facility (GIF) is studied. Results from two different types of chambers are discussed: 50 x 50 cm2 RPC prototypes and two final CMS-RB1 chambers. The RB1 detectors were also connected to a closed loop gas system. Gas composition, possible additional impurities as well as fluoride ions have been monitored in different gamma irradiation conditions both in open and closed loop mode. The chemical composition of the RPC electrode surface has also been analyzed using an electron microscope equipped with an EDS/X-ray

  17. Temperature characterisation of the CLOUD chamber at CERN

    Science.gov (United States)

    Dias, A. M.; Almeida, J.; Kirkby, J.; Mathot, S.; Onnela, A.; Vogel, A.; Ehrhart, S.

    2014-12-01

    Temperature stability, uniformity and absolute scale inside the CLOUD (Cosmics Leaving OUtdoor Droplets) chamber at CERN are important for experiments on aerosol particle nucleation and ice/liquid cloud formation. In order to measure the air temperature, a comprehensive set of arrays ("strings") of platinum resistance thermometers, thermocouples and optical sensors have been installed inside the 26 m3 chamber. The thermal sensors must meet several challenging design requirements: ultra-clean materials, 0.01 K measurement sensitivity, high absolute precision (thermometer strings and the thermal performance of the chamber during the CLOUD8 and CLOUD9 campaigns, 2013-2014, together with the planned upgrades of the CLOUD thermal system.

  18. Achievable field strength in reverberation chambers

    Directory of Open Access Journals (Sweden)

    N. Eulig

    2003-01-01

    automotive systems, immunity tests with field strengths of several 100 V/m are necessary. Such high field strengths can only be generated with substantial RF power and therefore expensive amplifiers if the test is performed in an environment with plane waves. Due to resonance effects in mode-stirred chambers, comparable values of the field strength can there be obtained with significantly less power. In these chambers the field strength declines with increasing volume for a constant input power. As an ideal testing environment a mode-stirred chamber should also work at low frequencies which requires a large volume, however. Hence there is a contradiction between generating high level field strengths on the one hand and obtaining a lowest usable frequency of several 10 MHz on the other. This relativizes the advantage of generating high field strengths with less power if the chamber is supposed to work down to low frequencies. This article deals with the field strengths that can be obtained in mode-stirred chambers with a certain size. Data of different mode-stirred chambers are compared. From this a frequency limit can be derived, above which the use a mode-stirred chamber for achieving high field strengths seems meaningful only.

  19. Drosophila egg chamber elongation

    OpenAIRE

    Gates, Julie

    2012-01-01

    As tissues and organs are formed, they acquire a specific shape that plays an integral role in their ability to function properly. A relatively simple system that has been used to examine how tissues and organs are shaped is the formation of an elongated Drosophila egg. While it has been known for some time that Drosophila egg elongation requires interactions between a polarized intracellular basal actin network and a polarized extracellular network of basal lamina proteins, how these interac...

  20. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  1. Particle detection with drift chambers

    CERN Document Server

    Blum, Walter; Rolandi, Luigi

    2008-01-01

    This volume presents a thorough introduction to the theory and operation of drift chambers, one of the most important modern methods of elementary particle detection. The topics, presented in a text-book style with many illustrations, include the basics of gas ionization, by particles and by lasers, drift of electrons and ions in gases and signal creation and discuss in depth the fundamental limits of accuracy and the issue of particle identification. The book also surveys all types of drift chambers and the various drift-chamber gases in use. The calculation of the device parameters and physical processes are presented in some detail, as is all necessary background material. Thus the treatment, well beyond addressing the specialist in the field, is well suited to graduate physics students and nuclear engineers seeking a both thorough and pedagogical introduction to the field. The second edition presents a completely revised, updated and expanded version of this classic text. In particular, significantly more...

  2. Impedances of Laminated Vacuum Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burov, A.; Lebedev, V.; /Fermilab

    2011-06-22

    First publications on impedance of laminated vacuum chambers are related to early 70s: those are of S. C. Snowdon [1] and of A. G. Ruggiero [2]; fifteen years later, a revision paper of R. Gluckstern appeared [3]. All the publications were presented as Fermilab preprints, and there is no surprise in that: the Fermilab Booster has its laminated magnets open to the beam. Being in a reasonable mutual agreement, these publications were all devoted to the longitudinal impedance of round vacuum chambers. The transverse impedance and the flat geometry case were addressed in more recent paper of K. Y. Ng [4]. The latest calculations of A. Macridin et al. [5] revealed some disagreement with Ref. [4]; this fact stimulated us to get our own results on that matter. Longitudinal and transverse impendances are derived for round and flat laminated vacuum chambers. Results of this paper agree with Ref. [5].

  3. General purpose nuclear irradiation chamber

    International Nuclear Information System (INIS)

    Nuclear technology has found a great need for use in medicine, industry, and research. Smoke detectors in our homes, medical treatments and new varieties of plants by irradiating its seeds are just a few examples of the benefits of nuclear technology. Portable neutron source such as Californium-252, available at Industrial Technology Division (BTI/ PAT), Malaysian Nuclear Agency, has a 2.645 year half-life. However, 252Cf is known to emit gamma radiation from the source. Thus, this chamber aims to provide a proper gamma shielding for samples to distinguish the use of mixed neutron with gamma-rays or pure neutron radiation. The chamber is compatible to be used with other portable neutron sources such as 241Am-Be as well as the reactor TRIGA PUSPATI for higher neutron dose. This chamber was designed through a collaborative effort of Kulliyyah Engineering, IIUM with the Industrial Technology Division (BTI) team, Malaysian Nuclear Agency. (Author)

  4. Characterization and application of two extrapolation chambers in standard X radiation beams

    International Nuclear Information System (INIS)

    The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers. (author)

  5. CFD Simulation Evaluation for Flow Distribution of the Closed Chamber

    Directory of Open Access Journals (Sweden)

    Hong Bin

    2016-01-01

    Full Text Available Taking a closed chamber flow field as object, this paper establishes the 3D model of the Closed Chamber. With the conclusion of flow distribution and gasoline vapor concentration distribution of the Closed Chamber reached via the CFD software of Fluent and experiment research, this paper analyzes the flow distribution and concentration distribution of gasoline vapor. Several improvement projects are proposed, such as improving the wind circulation system to optimize the indoor gas concentration. By improving the structure of wind circulation system, it makes flow distribution more reasonable and significantly improves the uniformity of indoor gas concentration. Through implementation of this improvement, the reliability and performance of the containment chamber obviously program to improve.

  6. The knife-edge chamber

    International Nuclear Information System (INIS)

    In this paper the design for a new technology for particle track detectors is described. Using standard IC fabrication techniques, a pattern of microscopic knife edges and field-shaping electrodes can be fabricated on a silicon substrate. The knife-edge chamber uniquely offers attractive performance for the track chambers required for SSC detectors, for which no present technology is yet satisfactory. Its features include: excellent radiation hardness (10 Mrad), excellent spatial resolution (∼20 μm), short drift time (20 ns), and large pulse height (1 mV)

  7. Test chamber for alpha spectrometry

    Science.gov (United States)

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  8. Bubble Chamber Research Group Microcomputer Unit

    International Nuclear Information System (INIS)

    A distributed data acquisition system has been developed by the Bubble Chamber Research Group at the Rutherford Appleton laboratory for use with their film measuring machines. The system is based upon a set of microcomputers linked together with a VAX 11/780 computer, in a local area computer network. This network is of the star type and uses a packet switching technique. Each film measuring machine is equipped with a microcomputer which controls the function of the table, buffers data and enhances the interface between operators and machines. This paper provides a detailed description of each microcomputer and can be used as a reference manual for these computers. (author)

  9. Some recent results for nonlinear acoustics in combustion chambers

    OpenAIRE

    Culick, F. E. C.

    1990-01-01

    Conditions of high energy densities and low losses in combustion chambers encourage the excitation and sustenance of organized unsteady motions generically called combustion instabilities. The fluctuations, common in propulsion systems, often reach sufficient amplitudes to cause excessive rates of heat transfer to exposed surfaces and unacceptable structural vibrations, causing failure in extreme cases. In many cases, to avoid the occurrence of instabilities, combustion chambers are ...

  10. Drift and proportional tracking chambers

    International Nuclear Information System (INIS)

    Many techniques have been exploited in constructing tracking chambers, particle detectors which measure the trajectories and momenta of charged particles. The particular features of high-energy interactions - charged particle multiplicities, angular correlations and complex vertex topologies, to name a few - and the experimental environment of the accelerator - event rates, background rates, and so on - accent the importance of certain detector characteristics. In high energy e+e-, anti pp and pp interactions the final states are dominated by closely collimated jets of high multiplicity, requiring good track-pair resolution in the tracking chamber. High energy particles deflect very little in limited magnetic field volumes, necessitating good spatial resolution for accurate momentum measurements. The colliding beam technique generally requires a device easily adapted to full solid-angle coverage, and the high event rates expected in some of these machines put a premium on good time resolution. Finally, the production and subsequent decays of the tau, charmed and beautiful mesons will provide multiple vertex topologies. To reconstruct these vertices reliably will require considerable improvements in spatial resolution and track-pair resolution. This lecture considers the proportional counter and its descendant, the drift chamber, as tracking chambers. Its goal is to review the physics of this device in order to understand its performance limitations and promises

  11. DELPHI's Ring Imaging Cherenkov Chamber

    CERN Multimedia

    1989-01-01

    The hundreds of mirrors around this Ring Imaging Cherenkov Chamber reflect cones of light created by fast moving particles to a detector. The velocity of a particle can be measured by the size of the ring produced on the detector. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  12. Bubble chamber: colour enhanced tracks

    CERN Multimedia

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  13. Chamber Quality Factors for the NACP-02 Chamber in 60Co Beams: Comparison of EGSnrc and PENELOPE Monte Carlo Simulations

    International Nuclear Information System (INIS)

    A new comparison of the values published for the chamber quality factor fc,Q0 of a NACP-02 plane-parallel chamber in 60Co, calculated with the Monte Carlo (MC) systems EGSnrc and PENELOPE, shows a difference of approximately 0.5%. The authors analyse possible reasons for this difference and recalculate the chamber quality factor with EGSnrc. Variations in the simulation transport parameters of EGSnrc result in changes smaller than the difference. An investigation of the most important uncertainties of cross-sectional data, considering variations in the mean excitation energy of stopping powers and in the total photon cross-sections, shows uncertainties comparable to the differences between the two codes for the chamber quality factor. Variations of the front wall thickness of the NACP-02 chamber, in the range of discrepancies with manufacturer data reported in the literature, result in significant changes in the calculated values. However, the difference in fc,Q0 cannot be explained in terms of these modifications. Hence, although both codes have been demonstrated to yield artefact free ion chamber simulations, a convergence of results for this particular problem cannot be achieved. An uncertainty estimate which takes into account the 0.5% difference for the MC calculated chamber quality factors seems to be a reasonable assumption. (author)

  14. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma irradiator

  15. Environmental Fate of Synthetic Drilling fluids from Offshore Drilling Operations - An Experimental Study of an Olefin-, Ether- and Ester-Based Mud System on Cuttings Deposited in Benthic Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Schaanning, M.T.

    1996-03-01

    In offshore drilling operations, much of the mineral oil previously used in mud systems has been replaced by synthetic drilling fluid. The chemicals enter the North Sea environment attached to bore hole cuttings deposited on the seabed near the discharge sites. After deposition, erosion may occur by biodegradation, bioturbation, resuspension and release to the water mass of dissolved chemicals or metabolites. In the investigation described in this report aliquots of control sediment and three types of cuttings were deposited in duplicate benthic chambers. During an experimental period of 161 days, the loss of drilling fluids from the sediments as well as the change of the ratio between drilling fluid and barium was measured. The mineralization of drilling carbon fluid to CO{sub 2} and water was calculated from oxygen consumption measurements and effects on sediment pH and redox potentials were determined at various time intervals. 10 refs., 13 figs., 25 tabs.

  16. In vivo determination of the {sup 99m}Tc-MDP incorporated activity in bone tissue; Determinacao in vivo da atividade incorporada de {sup 99m} Tc-MDP no tecido osseo

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Joseane Fonseca; Braga, Francisco J.H.N. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica; Dantas, Bernardo M.; Bertelli, Luiz [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Ghilardi Netto, Thomaz [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias da Imagem e Fisica Medica

    1998-07-01

    For determining in vivo {sup 99m}Tc-MDP incorporated activity in bone tissue using a scintillation chamber as a image detection and acquisition system it is necessary the system calibration using an anthropomorphic physical simulator. The development of a tibia and fibula simulator in order to estimate bone tissue activity is presented. This procedure can be used either for workers monitoring or for the metabolic behavior of this radiopharmaceutical.

  17. Analysis of micro-particles in TRISTAN vacuum chambers

    International Nuclear Information System (INIS)

    Micro-particles in the beam chamber of a TRISTAN vacuum system were investigated from the point of view of suppressing micro-particles trapped in the accumulation ring. Micro-particles coming from ion pumps (IP) and distributed ion pumps (DIP), aluminium alloy particles produced during treatment of aluminium alloy chambers for welding, micro-particles from the environment, i.e.soil (granite rocks or amphiboles), particles of concrete and painting materials were identified. A molten iron particle found in a chamber suggests interaction between the particle and bunched electron beam. Most of the particles coming from outside the chambers can be avoided by using high class clean rooms. The particles from the ion pumps can be reduced using different pumps which do not emit particles. The particles produced during assembly of, for example, DIP must be suppressed by accepting different assembling from the traditional ones. (author)

  18. Dirofilaria in the anterior chamber: A rare occurrence

    Directory of Open Access Journals (Sweden)

    Rupali Chopra

    2012-01-01

    Full Text Available Dirofilariasis is a parasitic infection of the carvivores that may present as a zoonotic infestation in humans. Systemic involvement in man is subcutaneous, pulmonary, or ocular. We report a rare occurrence of ocular dirofilariasis in a 25-year-old male patient who presented with pain and redness in the eye. A live, white, coiled, and highly motile worm was present in the anterior chamber. The worm, however, could not be detected in the anterior chamber, posterior segment, or the angle of the anterior chamber when the patient was taken to the operating room for surgical removal of the worm. The patient was made to lie prone till the worm reappeared in the anterior chamber and was removed by paracentesis. The worm was identified as Dirofilaria repens on the basis of microscopic and histopathological examination.

  19. Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer

    CERN Document Server

    Bauer, F; Dietl, H.; Kroha, H.; Lagouri, Th.; Manz, A.; Ostapchuk, A.; Richter, Robert, 1; Schael, S.; Chouridou, S.; Deile, M.; Kortner, O.; Staude, A.; Stroehmer, R.; Trefzger, T.

    2001-01-01

    The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started.

  20. Measuring chamber of the device for determination of the wear particle radioactivity

    International Nuclear Information System (INIS)

    Proposed is a measuring chamber for a device designed for determining radioactivity of wear particles in the system of lubrication of an internal-combustion engine. The chamber consists of of a case with two chambers for supplying oil to a cylindrical cavity of the chamber and of one channel for offtake from the cavity. A characteristic feature of the invention is that for increasing the accuracy of measurements the supplying channels are tangetial relative to the internal surface of the cavity, and the offtake channel is radial and located between them. The application of the chamber decrease measurement errors from 20-30% to 5-6%

  1. An examination of medical linear accelerator ion-chamber performance

    International Nuclear Information System (INIS)

    Full text: The company ( Radiation Oncology Physics and Engineering Services Pty Ltd) provides medical physics services to four radiotherapy centres in NSW with a total of 6 high energy medical linear accelerators manufactured by three different companies. As part of the services, the stability of the accelerator ion chamber system is regularly examined for constancy and periodically for absolute calibration. Each accelerator ion chamber has exhibited undesirable behaviour from time to time, sometimes leading to its replacement. This presentation describes the performance of the ion chambers for some of the linacs over a period of 12-18 months and the steps taken by the manufacturer to address the problems encountered. As part of our commissioning procedure of new linacs, an absolute calibration of the accelerator output (photon and electron beams) is repeated several times over the period following examination of the physical properties of the radiation beams. These calibrations were undertaken in water using the groups calibrated ion chamber/electrometer system and were accompanied by constancy checks using an acrylic phantom and field instruments. Constancy checks were performed daily for a period of 8 weeks during the initial life of the accelerator and thereafter weekly. For one accelerator, the ion chamber was replaced 6 times in the first eighteen months of its life due to severe drifts in output, found to be due to pressure changes in one half of the chamber In another accelerator, erratic swings of 2% were observed for a period of nine months, particularly with the electron beams, before the manufacturer offered to change the chamber with another constructed from different materials. In yet another accelerator the ion chamber has shown consistent erratic behaviour, but this has not been addressed by the manufacturer. In another popular accelerator, the dosimetry was found to be very stable until some changes in the tuning were introduced resulting in small

  2. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    A walk-in type radon test chamber of 23 m3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  3. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E;

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol......-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were...

  4. Chamber dynamic research with pulsed power

    Energy Technology Data Exchange (ETDEWEB)

    PETERSON,ROBERT R.; OLSON,CRAIG L.; RENK,TIMOTHY J.; ROCHAU,GARY E.; SWEENEY,MARY ANN

    2000-05-15

    In Inertial Fusion Energy (IFE), Target Chamber Dynamics (TCD) is an integral part of the target chamber design and performance. TCD includes target output deposition of target x-rays, ions and neutrons in target chamber gases and structures, vaporization and melting of target chamber materials, radiation-hydrodynamics in target chamber vapors and gases, and chamber conditions at the time of target and beam injections. Pulsed power provides a unique environment for IFE-TCD validation experiments in two important ways: they do not require the very clean conditions which lasers need and they currently provide large x-ray and ion energies.

  5. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    OpenAIRE

    Hohaus, T.; Kuhn, U.; S. Andres; Kaminski, M.; Rohrer, F.; Tillmann, R.; A. Wahner; R. Wegener; Yu, Z.; Kiendler-Scharr, A.

    2015-01-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber ...

  6. Rapid Manufacture of Combustion Chambers Using Ductile, High Strength MMCs (1000-803) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Triton Systems, Inc. (Triton) proposes to develop a cost-effective manufacturing approach to fabricate combustion chambers for a rocket technology demonstrator...

  7. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  8. LEP vacuum chamber, early prototype

    CERN Multimedia

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  9. Performance Analysis of a Multiple Chamber Trough Concentrating Photovoltaic/Thermal System%多曲面槽式聚光太阳电池电热联供系统性能研究

    Institute of Scientific and Technical Information of China (English)

    常泽辉; 郑宏飞; 侯静; 戴静

    2012-01-01

    A multiple chamber trough solar collector and its working principle were presented. A 3D model of the corrector supported with optical analysis software was used to analyze the ray tracing of the flat-plate solar cell panel. The distribution of the concentrated light could be visualized. Based on the multiple chamber trough concentrator, a novel multiple chamber trough concentrating polycrystalline silicon photovoltaic/thermal system (TCPV/T) was proposed. The TCPV/T system could provide both the power and heat. Solar energy could be efficiently utilized with the combined cycle system and the output electrical power as well as electrical efficiency of the solar cell be enhanced. An experimental set combined heating and power devices driven by solar concentrating trough was constructed. Experiment results indicate that, under about 3 times of solar concentrating, the maximum output power produced by TCPV/T system is higher than that of flat-plate photovoltaic (PV) system and trough concentrating photovoltaic system by 96. 4% and 64. 2%, respectively. The synthetic energy-saving efficiency of TCPV/T system is 62. 8%.%介绍了一种多曲面槽式太阳能聚光器的工作原理,对该装置进行了三维建模,利用光学分析软件对该聚光器安装平板式太阳电池进行光线追迹分析,直观地再现了聚焦光线的分布.基于该多曲面槽式聚光系统,提出一种新型的聚光太阳电池电热联供系统(TCPV/T).该系统能够有效利用太阳辐射能量,提高太阳电池输出电功率、光电转换效率,并将太阳电池产生的热量有效回收,实现聚光发电系统对外输出电能、热能.构建了多曲面槽式聚光多晶硅太阳电池电热联供实验系统.实验结果表明,在约3倍太阳聚光作用下,与非聚光平板电池、安装于同一聚光器内的太阳电池输出电功率相比,聚光电热联供系统输出最大电功率分别提高了96.4%和64.2%,系统综合性能效率达到62.8%.

  10. Bubble chambers for experiments in nuclear astrophysics

    Science.gov (United States)

    DiGiovine, B.; Henderson, D.; Holt, R. J.; Raut, R.; Rehm, K. E.; Robinson, A.; Sonnenschein, A.; Rusev, G.; Tonchev, A. P.; Ugalde, C.

    2015-05-01

    A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with γ-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross-sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time-reversed processes. Such photodisintegrations allow us to compute the radiative capture cross-sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross-sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the γ-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed.

  11. Bubble chambers for experiments in nuclear astrophysics

    International Nuclear Information System (INIS)

    A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with γ-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross-sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time-reversed processes. Such photodisintegrations allow us to compute the radiative capture cross-sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross-sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the γ-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed

  12. SMOG CHAMBER VALIDATION USING LAGRANGIAN ATMOSPHERIC DATA

    Science.gov (United States)

    A method was developed for validating outdoor smog chamber experiments as a means of determining the relationships between oxidant concentrations and its precursors - hydrocarbons and nitrogen oxides. When chamber experiments were performed in a manner that simulated relevant met...

  13. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E;

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London......-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were...

  14. NRAO RF Anechoic Chamber & Antenna Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  15. Nuclear Design Considerations for Z-IFE Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R; Schmitt, R C; Abbott, R P; Latkowski, J F; Reyes, S

    2005-02-02

    Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets ({approx}2-3 GJ/shot), low repetition rate per chamber ({approx}0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (x-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped Recyclable Transmission Line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here.

  16. Aging in the large CDF axial drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Allspach, D.; Ambrose, D.; Binkley, M.; /Fermilab; Bromberg, C.; /Michigan State U.; Burkett, K.; Kephart, R.; Madrak, R.; Miao, T.; Mukherjee, A.; Roser, R.; Wagner, R.L.

    2004-12-01

    The Central Outer Tracker (COT) is a large axial drift chamber in the Collider Detector at Fermilab operating with a gas mixture that is 50/50 argon/ethane with an admixture of 1.7% isopropanol. In its first two years of operation the COT showed unexpected aging with the worst parts of the chamber experiencing a gain loss of {approx}50% for an accumulated charge of {approx}35 mC/cm. By monitoring the pulse height of hits on good tracks, it was possible to determine the gain as a function of time and location in the chamber. In addition, the currents of the high voltage supplies gave another monitor of chamber gain and its dependence on the charge deposition rate. The aging was worse on the exhaust end of the chamber consistent with polymer buildup as the gas flows through the chamber. The distribution in azimuth suggests that aging is enhanced at lower temperatures, but other factors such as gas flow patterns may be involved. Elemental and molecular analysis of the sense wires found a coating that is mostly carbon and hydrogen with a small amount of oxygen; no silicon or other contaminants were identified. High resolution electron microscope pictures of the wire surface show that the coating is smooth with small sub-micron nodules. In the course of working with the chamber gas system, we discovered a small amount of O{sub 2} is enough to reverse the aging. Operating the chamber with {approx}100 ppm of O{sub 2} reversed almost two years of gain loss in less than 10 days while accumulating {le} 2 mC/cm.

  17. Nuclear design considerations for Z-IFE chambers

    International Nuclear Information System (INIS)

    Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets (∼2-3 GJ/shot), low repetition rate per chamber (∼0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (X-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped recyclable transmission line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here

  18. Ionization chamber kit for in core dosimetry

    International Nuclear Information System (INIS)

    Sensitivity of a set of ionization walled precise chambers, including chambers with a wall made of a material with different atomic number Z (from 6 to 92), is investigated. It is noted that the considered chambers differ by high radiation stability at slight leakage current on isolators. Using the chambers for determining effective energy of gamma-radiation of the stopped IRT-2000 reactor has shown a good agreement of measuring results with the calculation

  19. Design of a Fully Anechoic Chamber

    OpenAIRE

    Rusz, Roman

    2015-01-01

    This thesis deals with fully anechoic chamber design. The main aim of this thesis is to design fully anechoic chamber according to acoustics laws and customers (Honeywell’s) requirements. The fully anechoic chamber will be used for measuring sound and vibration quantities. This work is divided into two main parts. The first part deals with the general anechoic chamber theory and all its related design aspects. The second part, practical part, focus on specific design according to requirements...

  20. LEP vacuum chamber cross-section

    CERN Multimedia

    1987-01-01

    This diagram shows the layout of the vacuum chambers used at LEP, which was in operation at CERN between 1989 and 2000. Vacuum chambers are necessary in accelerators to prevent unwanted interactions that can destabilise the beam. The pump on the right sucks air out of the chamber allowing the beam to progress with minimal interactions.

  1. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  2. A cryogenic chamber for scattering measurements

    OpenAIRE

    Lopes, M. I.; Chepel, V.; Kuchenkov, A.; Gonçalves, O. D.; Schechter, H.

    1999-01-01

    We have constructed a cryogenic chamber to measure scattering cross sections of photons in liquids of low-boiling point. The chamber was tested with liquid xenon using a 137Cs radioactive source emitting 662 keV photons. The spectra obtained are presented and analyzed, attesting the good performance of the chamber for the desired purposes.

  3. Sensitivity of gaseous xenon ionisation chambers (1961)

    International Nuclear Information System (INIS)

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author)

  4. Cosmic test of honeycomb drift chambers

    International Nuclear Information System (INIS)

    The status of the test of pokalon-C honeycomb drift chambers by cosmic rays is presented. We discuss the cosmic track reconstruction, autocalibration of drift chambers and identification of cross-talk hits. Preliminary results of the test performed for drift chambers with 5 mm cells are given

  5. Subminiature fission chamber with gas tight penetration

    International Nuclear Information System (INIS)

    Fission chambers suffer from gas leaks at electric feed-trough. This micro chamber suppresses that defect thanks to an alumina plug and welded seal of the chamber sleeve. This device is easy to produce at industrial scale with reduced dimensions (1,5 mm diameter, 25 mm length). It can work with 30 m long feeding cables. (D.L.). 3 figs

  6. A Sensitive Cloud Chamber without Radioactive Sources

    Science.gov (United States)

    Zeze, Syoji; Itoh, Akio; Oyama, Ayu; Takahashi, Haruka

    2012-01-01

    We present a sensitive diffusion cloud chamber which does not require any radioactive sources. A major difference from commonly used chambers is the use of a heat sink as its bottom plate. The result of a performance test of the chamber is given. (Contains 8 figures.)

  7. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  8. Vacuum chamber at intersection I-6

    CERN Multimedia

    1971-01-01

    The vacuum chamber at intersection region I-6, one of these where experiments in colliding-beam physics will be taking place. The "wheels" prevent the thin wall (1.5 mm) of the chamber from collapsing. The chamber is equipped with heating tapes and its wrapped in thermal insulation. Residual gas pressure at this and other similar regions is around 10_11.

  9. Design of basic chamber of the Main Control Valve

    Directory of Open Access Journals (Sweden)

    S.W. Lee

    2008-06-01

    Full Text Available Purpose: The development of a control valve for closed circuit requires comprehensive technologies in the overall precision machinery industry, from the development of casting materials for the housing to various types of parts. The development of a new type of control valve would have great advantage with a long lifecycle. Therefore, it is necessary to secure the MCV (Main Control Valve development technology that applies various sensors. This paper aims at providing a fundamental base for the establishment of design systems including the flow chamber design database of the MCV for wheel loaders, strength and rigidity design system, and the system for energy efficiency improvement. Particularly, this study set up the basic design database for the flow chamber design to establish the flow chamber design database, and secured the stability of the flow chamber from the basic design stage. In addition, major design variables were determined by utilizing a statistical technique in order to design such flow chamber.Design/methodology/approach: This study uses the I-DEAS to analyze the MCV structure characteristics. In addition, it uses the factorial design and sensitivity analysis to select important factors for the MCV design.Findings: This study establishes the unit flow chamber database for the MCV housing unit and the governing equation for the flow chamber.Research limitations/implications: Since the MCV damage often occurs due to the problem with the material itself and in the manufacturing process, it is difficult to tell clearly whether it occurred as the MCV reached the failure pressure.Practical implications: The basic data needed to design the MCV can be provided, and the required time for the design and the reliability of the design can be reduced and improved respectively.Originality/value: The verification of the design factors obtained from the flow analysis and structural analysis as well as the DOE was made by fabricating a sample

  10. The Low Chamber Pancreatic Cancer Cells Had Stem-Like Characteristics in Modified Transwell System: Is It a Novel Method to Identify and Enrich Cancer Stem-Like Cells?

    Directory of Open Access Journals (Sweden)

    Dongqing Wang

    2014-01-01

    Full Text Available Cancer stem cells (CSCs or cancer-initiating cells (CICs play an important role in tumor initiation, progression, metastasis, chemoresistance, and recurrence. It is important to construct an effective method to identify and isolate CSCs for biotherapy of cancer. During the past years, many researchers had paid more attention to it; however, this method was still on seeking. Therefore, compared to the former methods that were used to isolate the cancer stem cell, in the present study, we tried to use modified transwell system to isolate and enrich CSCs from human pancreatic cancer cell lines (Panc-1. Our results clearly showed that the lower chamber cells in modified transwell system were easily forming spheres; furthermore, these spheres expressed high levels of stem cell markers (CD133/CD44/CD24/Oct-4/ESA and exhibited chemoresistance, underwent epithelial-to-mesenchymal transition (EMT, and possessed the properties of self-renewal in vitro and tumorigenicity in vivo. Therefore, we speculated that modified transwell assay system, as a rapid and effective method, can be used to isolate and enrich CSCs.

  11. Bubble Chambers for Experiments in Nuclear Astrophysics

    CERN Document Server

    DiGiovine, B; Holt, R J; Rehm, K E; Raut, R; Robinson, A; Sonnenschein, A; Rusev, G; Tonchev, A P; Ugalde, C

    2015-01-01

    A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time-reversed processes. Such photodisintegrations allow us to compute the radiative capture cross sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas tar...

  12. Liquid rocket combustion chamber acoustic characterization

    Directory of Open Access Journals (Sweden)

    Cândido Magno de Souza

    2010-09-01

    Full Text Available Over the last 40 years, many solid and liquid rocket motors have experienced combustion instabilities. Among other causes, there is the interaction of acoustic modes with the combustion and/or fluid dynamic processes inside the combustion chamber. Studies have been showing that, even if less than 1% of the available energy is diverted to an acoustic mode, combustion instability can be generated. On one hand, this instability can lead to ballistic pressure changes, couple with other propulsion systems such as guidance or thrust vector control, and in the worst case, cause motor structural failure. In this case, measures, applying acoustic techniques, must be taken to correct/minimize these influences on the combustion. The combustion chamber acoustic behavior in operating conditions can be estimated by considering its behavior in room conditions. In this way, acoustic tests can be easily performed, thus identifying the cavity modes. This paper describes the procedures to characterize the acoustic behavior in the inner cavity of four different configurations of a combustion chamber. Simple analytical models are used to calculate the acoustic resonance frequencies and these results are compared with acoustic natural frequencies measured at room conditions. Some comments about the measurement procedures are done, as well as the next steps for the continuity of this research. The analytical and experimental procedures results showed good agreement. However, limitations on high frequency band as well as in the identification of specific kinds of modes indicate that numerical methods able to model the real cavity geometry and an acoustic experimental modal analysis may be necessary for a more complete analysis. Future works shall also consider the presence of passive acoustic devices such as baffles and resonators capable of introducing damping and avoiding or limiting acoustic instabilities.

  13. UHV testing of upgraded vacuum chambers for Indus-1

    International Nuclear Information System (INIS)

    Indus-1 is a 450 MeV, 100 mA dedicated electron storage ring operating at pressure 10-10 mbar range without beam and 10-9 mbar range with beam using triode sputter ion pump (SIP) and titanium sublimation pump (TSP) combination. Indus-1 storage ring is presently working with six operational beam lines installed at three bending magnets. To accommodate two more beam lines and to reduce number of demountable joints, up-gradation of Indus-1 UHV system was planned. Salient features of upgraded vacuum system are bending magnet vacuum chambers with one extra port for additional beam line and straight section vacuum chambers with integrated TSP body. Half of the Indus-1 storage ring vacuum envelope with two bending magnet vacuum chamber and six straight section vacuum chambers were assembled with pumps, gauges etc, leak tested and tested for its UHV performance. Ultimate vacuum 5x10-10 mbar with SIP and 2x10-10 mbar after TSP pumping were achieved. Residual gas analyser (RGA) spectrum recorded for residual gas analysis indicated the imprints of a typical all metal UHV system having H2 as major gas. This paper describes UHV testing of upgraded, newly fabricated vacuum chambers for Indus-1 storage ring. (author)

  14. Choice of the recording arrangement for bubble chamber holography

    International Nuclear Information System (INIS)

    The main characteristics of the different recording arrangements are compared. The in-line system is the most simple and the cheapest but it does not suit to all types of chambers. The side-band systems yield different sorts of images and require different coherence, stability and energy conditions according to the type of illumination of the bubbles. (orig.)

  15. Determination of shielding factors for typical buildings in Brazil; Determinacao dos fatores de blindagem para construcoes tipicamente brasileiras

    Energy Technology Data Exchange (ETDEWEB)

    Salinas, Isabel Cristina Poquet

    2006-10-15

    This study presents a methodology for the determination of the air kerma inside buildings due to contamination on the external surfaces and the shielding factors for the construction material to be used on emergency assessment systems for urban areas. The commonly used construction materials were simulated with the MCNP computer code. A special methodology to simulate the bricks with holes were developed, mixing all different regions into a single one, making the simulation easier and faster. The effective density and the attenuation coefficients for the 50-3000 keV energy range were determined. The effective protection for the bricks with no cement cover decreases by 40-50% for energies greater then 300 keV when compared to bricks covered on both sides. With the data made available it was possible to evaluate the influence of the construction materials densities and thickness on the exposure due to external surfaces contamination and to estimate the error on the dose when the shielding factor applied on the calculation differs from the more realistic ones. The shielding factors for three types of walls were determined for a five rooms house. Special protection procedures should be applied for houses built with bricks with no cement cover, because they are due to the double of the dose when compared to houses built with bricks two-sided cement covered. The influence of windows and doors were evaluated too. This work was developed at the IRD in order to provide information on the construction material commonly uses on building in Brazil. (author)

  16. Design and construction of an inexpensive homemade plant growth chamber.

    Science.gov (United States)

    Katagiri, Fumiaki; Canelon-Suarez, Dario; Griffin, Kelsey; Petersen, John; Meyer, Rachel K; Siegle, Megan; Mase, Keisuke

    2015-01-01

    Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W) x 1.8 m (D) x 2 m (H), providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant growth chamber

  17. Design and construction of an inexpensive homemade plant growth chamber.

    Directory of Open Access Journals (Sweden)

    Fumiaki Katagiri

    Full Text Available Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W x 1.8 m (D x 2 m (H, providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant

  18. Cylindrical ionization chamber on compressed krypton

    International Nuclear Information System (INIS)

    A cylindrical ionization chamber with a grid is described. The chamber is used in experiments to search for double positron decay and conversion of atom electron into positron in Kr78. The working substance of the chamber is krypton. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. Energy resolution is 2.1% for 1.84 MeV energy (the gamma quantum source is 88Y) when using the chamber filled with Kr+0.2%H2 mixture at pressure of 25 atm

  19. Application of titanium materials to vacuum chambers and components

    International Nuclear Information System (INIS)

    This paper describes the outgassing properties of titanium materials, and development of vacuum chambers and components for practical UHV/XHV systems. The mechano-chemically polished and the chemically polished titanium materials have a smooth surface and a thin (≤ 10 nm) oxide surface layer, which showed extremely low outgassing rate below 10-12 Pams-1 after baking process. In order to fabricate practical vacuum systems welding, metallizing and brazing processes were optimized, and complex shaped vacuum chambers and various vacuum components such as a bellows, valve, electric feedthrough and ceramic duct with titanium sleeve were fabricated. Sufficient mechanical properties and durability were obtained for practical use

  20. Treatment of colour industry wastewaters with concomitant bioelectricity production in a sequential stacked mono-chamber microbial fuel cells-aerobic system.

    Science.gov (United States)

    Fernando, Eustace; Keshavarz, Taj; Kyazze, Godfrey; Fonseka, Keerthi

    2016-01-01

    The scalability of any microbial fuel cell (MFC)-based system is of vital importance if it is to be utilized for potential field applications. In this study, an integrated MFC-aerobic bioreactor system was investigated for its scalability with the purpose of treating a simulated dye wastewater and industrial wastewaters originated from textile dyebaths and leather tanning. The influent containing real wastewater was fed into the reactor in continuous mode at ambient temperature. Three MFC units were integrated to act in unison as a single module for wastewater treatment and a continuously stirred aerobic bioreactor operating downstream to the MFC module was installed in order to ensure more complete degradation of colouring agents found in the wastewater. Total colour removal in the final effluent exceeded 90% in all experiments where both synthetic (AO-7 containing) and real wastewater were used as the influent feed. The chemical oxygen demand reduction also exceeded 80% in all experiments under the same conditions. The MFC modules connected in parallel configuration allowed obtaining higher current densities than that can be obtained from a single MFC unit. The maximum current density of the MFC stack reached 1150 mA m(-2) when connected in a parallel configuration. The outcome of this work implies that suitably up-scaled MFC-aerobic integrated bioprocesses could be used for colour industry wastewater treatment under industrially relevant conditions with possible prospects of bioelectricity generation. PMID:26212183

  1. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki;

    2010-01-01

    Modern radiotherapy facilities for cancer treatment such as the Heavy Ion Therapy Centre (HIT) in Heidelberg (Germany) enable sub millimetre precision in dose deposition. For the measurement of such dose distributions and  characterization of the particle beams, detectors with high spatial...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  2. TRU waste characterization chamber gloveboxes

    International Nuclear Information System (INIS)

    Argonne National Laboratory-West (ANL-W) is participating in the Department of Energy's (DOE) National Transuranic Waste Program in support of the Waste Isolation Pilot Plant (WIPP). The Laboratory's support currently consists of intrusive characterization of a selected population of drums containing transuranic waste. This characterization is performed in a complex of alpha containment gloveboxes termed the Waste Characterization Gloveboxes. Made up of the Waste Characterization Chamber, Sample Preparation Glovebox, and the Equipment Repair Glovebox, they were designed as a small production characterization facility for support of the Idaho National Engineering and Environmental Laboratory (INEEL). This paper presents salient features of these gloveboxes

  3. Pupillary block glaucoma following implantation of a posterior chamber pseudophakos in the anterior chamber.

    Directory of Open Access Journals (Sweden)

    Mandal Anil

    2002-01-01

    Full Text Available Pupillary block glaucoma is a common complication of cataract surgery, especially following anterior chamber intraocular lens implantation. We report a case of pupillary block glaucoma with a posterior chamber IOL that was implanted in the anterior chamber following a complicated extracapsular cataract extraction. The case was successfully managed by explantation of the posterior chamber lens, anterior vitrectomy, peripheral iridectomy and secondary anterior chamber intraocular lens implantation. The intraocular pressure was controlled with a single topical antiglaucoma medication.

  4. Chamber Design for the Laser Inertial Fusion Energy (LIFE) Engine

    International Nuclear Information System (INIS)

    The Laser Inertial Fusion Energy (LIFE) concept is being designed to operate as either a pure fusion or hybrid fusion-fission system. The present work focuses on the pure fusion option. A key component of a LIFE engine is the fusion chamber subsystem. It must absorb the fusion energy, produce fusion fuel to replace that burned in previous targets, and enable both target and laser beam transport to the ignition point. The chamber system also must mitigate target emissions, including ions, x-rays and neutrons and reset itself to enable operation at 10-15 Hz. Finally, the chamber must offer a high level of availability, which implies both a reasonable lifetime and the ability to rapidly replace damaged components. An integrated design that meets all of these requirements is described herein.

  5. OPAL Central Detector (Including vertex, jet and Z chambers)

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the different parts of the tracking system. (This piece includes the vertex, jet and Z chambers) In the picture above, the central detector is the piece being removed to the right.

  6. Chamber Design for the Laser Inertial Fusion Energy (LIFE) Engine

    Energy Technology Data Exchange (ETDEWEB)

    Latkowski, J F; Abbott, R P; Aceves, S; Anklam, T; Badders, D; Cook, A W; DeMuth, J; Divol, L; El-Dasher, B; Farmer, J C; Flowers, D; Fratoni, M; ONeil, R G; Heltemes, T; Kane, J; Kramer, K J; Kramer, R; Lafuente, A; Loosmore, G A; Morris, K R; Moses, G A; Olson, B; Pantano, C; Reyes, S; Rhodes, M; Roe, K; Sawicki, R; Scott, H; Spaeth, M; Tabak, M; Wilks, S

    2010-11-30

    The Laser Inertial Fusion Energy (LIFE) concept is being designed to operate as either a pure fusion or hybrid fusion-fission system. The present work focuses on the pure fusion option. A key component of a LIFE engine is the fusion chamber subsystem. It must absorb the fusion energy, produce fusion fuel to replace that burned in previous targets, and enable both target and laser beam transport to the ignition point. The chamber system also must mitigate target emissions, including ions, x-rays and neutrons and reset itself to enable operation at 10-15 Hz. Finally, the chamber must offer a high level of availability, which implies both a reasonable lifetime and the ability to rapidly replace damaged components. An integrated design that meets all of these requirements is described herein.

  7. Development of Master Chamber Software for Data Acquisition of Ionization Chamber for Indus 2 RRCAT

    Directory of Open Access Journals (Sweden)

    Priyesh Soni

    2013-02-01

    Full Text Available The main goal of this paper was to Develop Master control software for DAQ of ionization chamber for INDUS-2 beam lines for detection of X-ray flux by an Ionization chamber that will remotely control and monitor the ultra low current signal detection analog module precisely. This application will be useful to measure the intensity of X-ray flux through ionization chamber in a beam line of synchrotron radiation source which is mounted in INDUS-2. It is one of new technique of detection. Beam line area is highly restricted because of hazardous radiation, so through this application remote interfacing is provided for the ultra low current signal detection card that can be controlled by Master software. The development of such type arrangement we used software in C#.NET there are many issues like develop code, Design forms, to achieve the specified response from the CPU card, code developed in C# .NET. Initially, I explored and gained the knowledge of C#.NET. I practices some small modular projects as part to learn how the system works. I used programming language C#.NET architecture version 3.5 in Visual Studio 2008

  8. Design and construction of the CLEO II drift chamber

    International Nuclear Information System (INIS)

    We have constructed a new large cylindrical drift chamber (2 m long and 2 m in diameter) for the CLEO II experiment at the Cornell Electron Storage Ring (CESR). The chamber contains 51 readout layers including 11 stereo layers, with 48480 (12240) total (sense) wires. Segmented cathode strips were used instead of field wires for the innermost and outermost layers to provide two accurate measurements of the longitudinal coordinate. Very low density support structures were developed to hold the cathode strips. Aluminium wire was used for the majority of the field wires to reduce multiple scattering and the tension load on the endplates. A semiautomatic apparatus was developed to string wires with the chamber mounted vertically. With this system, it was also possible to replace any wire in the chamber. A maximum stringing rate of 60 wires/h, was achieved. The tension on all wires was measured soon after they were strung; the failure rate due to improper tension was typically less than 2%. Hybrid preamplifiers were developed and mounted directly on the chamber on custom printed circuit boards. Each board also contains a pulser calibration system and a high voltage current monitor. High voltage power is individually supplied to each of the 51 layers under computer control. A new type of hardware track finder was developed for the trigger. (orig.)

  9. Bluetooth Communication Interface for EEG Signal Recording in Hyperbaric Chambers.

    Science.gov (United States)

    Pastena, Lucio; Formaggio, Emanuela; Faralli, Fabio; Melucci, Massimo; Rossi, Marco; Gagliardi, Riccardo; Ricciardi, Lucio; Storti, Silvia F

    2015-07-01

    Recording biological signals inside a hyperbaric chamber poses technical challenges (the steel walls enclosing it greatly attenuate or completely block the signals as in a Faraday cage), practical (lengthy cables creating eddy currents), and safety (sparks hazard from power supply to the electronic apparatus inside the chamber) which can be overcome with new wireless technologies. In this technical report we present the design and implementation of a Bluetooth system for electroencephalographic (EEG) recording inside a hyperbaric chamber and describe the feasibility of EEG signal transmission outside the chamber. Differently from older systems, this technology allows the online recording of amplified signals, without interference from eddy currents. In an application of this technology, we measured EEG activity in professional divers under three experimental conditions in a hyperbaric chamber to determine how oxygen, assumed at a constant hyperbaric pressure of 2.8 ATA , affects the bioelectrical activity. The EEG spectral power estimated by fast Fourier transform and the cortical sources of the EEG rhythms estimated by low-resolution brain electromagnetic analysis were analyzed in three different EEG acquisitions: breathing air at sea level; breathing oxygen at a simulated depth of 18 msw, and breathing air at sea level after decompression. PMID:25608308

  10. Around the laboratories: Rutherford: Successful tests on bubble chamber target technique; Stanford (SLAC): New storage rings proposal; Berkeley: The HAPPE project to examine cosmic rays with superconducting magnets; The 60th birthday of Professor N.N. Bogolyubov; Argonne: Performance of the automatic film measuring system POLLY II

    CERN Multimedia

    1969-01-01

    Around the laboratories: Rutherford: Successful tests on bubble chamber target technique; Stanford (SLAC): New storage rings proposal; Berkeley: The HAPPE project to examine cosmic rays with superconducting magnets; The 60th birthday of Professor N.N. Bogolyubov; Argonne: Performance of the automatic film measuring system POLLY II

  11. Physicist makes muon chamber sing

    CERN Document Server

    2007-01-01

    This Monitored Drift Tube detector, consisting of argon-CO2-filled aluminium tubes with a wire down the centre of each, will track muons in ATLAS; Tiecke used a single tube from one of these detectors to create the pipes in his organ. Particle physicists can make good musicians; but did you know particle detectors can make good music? That's what NIKHEF physicist Henk Tiecke learned when he used pipes cut from the ATLAS Monitored Drift Tube detector (MDT) to build his own working Dutch-style barrel organ in the autumn of 2005. 'I like to work with my hands,' said Tiecke, who worked as a senior physicist at NIKHEF, Amsterdam, on ZEUS until his retirement last summer. Tiecke had already constructed his barrel organ when he visited some colleagues in the ATLAS muon chambers production area at Nikhef in 2005. He noticed that the aluminium tubes they were using to build the chambers were about three centimetres in diameter-just the right size for a pipe in a barrel organ. 'The sound is not as nice as from wooden...

  12. Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber

    International Nuclear Information System (INIS)

    PicoRad system based on activated charcoal collectors and liquid scintillation counter is one of the most popular passive methods of radon measurements which may be used both indoors and in other environments such as caves, tunnels, mines etc. It is well known that charcoal is also a very good adsorber of water vapor and it can reduce adsorption efficiency for radon. In PicoRad collectors, the charcoal is mixed with a dessicant to lower this effect. A series of expositions of PicoRad detectors was performed in a Central Laboratory for Radiological Protection (CLOR) radon calibration/climatic chamber to study the effect of high relative humidity on the airborne radon concentration measurements and the dependence of the results on the duration of exposure. The results obtained from the PicoRad system were referred to the mean concentrations delivered by an AlphaGUARD monitor, Genitron (GmbH), Germany. The main conclusions are the following: 1) the PicoRad system results are not affected by high relative humidity, including extreme values of 90-96%, for the duration of exposure up to ca. 24 h; 2) in the relative humidity range of 75-96% the correction coefficient linearly depends on the duration of exposure reaching a value of ca. 16 for 96 h exposure; 3) the PicoRad system delivers results corresponding better to the mean value of radon concentration in the last 6 h interval of exposure than that in the whole exposure duration. This finding is particularly important for the calibration of PicoRad collectors in the conditions of decreasing radon concentration due to radon decay. (author)

  13. Characterization and testing of a new environmental chamber

    Science.gov (United States)

    Leskinen, A.; Yli-Pirilä, P.; Kuuspalo, K.; Sippula, O.; Jalava, P.; Hirvonen, M.-R.; Jokiniemi, J.; Virtanen, A.; Komppula, M.; Lehtinen, K. E. J.

    2015-06-01

    A 29 m3 Teflon chamber, designed for studies on the aging of combustion aerosols, at the University of Eastern Finland is described and characterized. The chamber is part of a research facility, called Ilmari, where small-scale combustion devices, a dynamometer for vehicle exhaust studies, dilution systems, the chamber, and cell and animal exposure devices are located side by side under the same roof. The small surface-to-volume ratio of the chamber enables reasonably long experiment times, with particle wall loss rate constants of 0.088, 0.080, 0.045, and 0.040 h-1 for polydisperse, 50, 100, and 200 nm monodisperse aerosols, respectively. The NO2 photolysis rate can be adjusted from 0 to 0.62 min-1. The irradiance spectrum is centered at either 350 or 365 nm, and the maximum irradiance, produced by up to 160 blacklight lamps, is 29.7 W m-2, which corresponds to the ultraviolet (UV) irradiance in Central Finland at noon on a sunny day in the midsummer. The temperature inside the chamber is uniform and can be kept at 25±1 °C. The chamber is kept in an overpressure with a moving top frame, which reduces sample dilution and entrance of contamination during an experiment. The functionality of the chamber was tested with oxidation experiments of toluene, resulting in secondary organic aerosol (SOA) yields of 12-42%, depending on the initial conditions, such as NOx concentration and UV irradiation. The highest gaseous oxidation product yields of 12.4-19.5% and 5.8-19.5% were detected with ions corresponding to methyl glyoxal (m/z 73.029) and 4-oxo-2-pentenal (m/z 99.044), respectively. Overall, reasonable yields of SOA and gaseous reaction products, comparable to those obtained in other laboratories, were obtained.

  14. Hypobaric chamber for the study of oral health problems in a simulated spacecraft environment

    Science.gov (United States)

    Brown, L. R.

    1974-01-01

    A hypobaric chamber was constructed to house two marmo-sets simultaneously in a space-simulated environment for periods of 14, 28 and 56 days which coincided with the anticipated Skylab missions. This report details the fabrication, operation, and performance of the chamber and very briefly reviews the scientific data from nine chamber trials involving 18 animals. The possible application of this model system to studies unrelated to oral health or space missions is discussed.

  15. Design and Optimization of Cylindrical Vacuum Chamber for Multitask Testing System of Neutral Beam Injector%NBI综合测试台真空筒体的结构分析及优化

    Institute of Scientific and Technical Information of China (English)

    孟冠军; 曹文钢; 章亮亮; 谢远来; 胡纯栋

    2013-01-01

    The cylindrical vacuum chamber, consisting of three cylinders and dedicated to the multi-task testing system for the neutral beam injector (NBI) of the thermonuclear fusion device, was designed and optimized. Hie stress and static force distributions in the major parts of the vacuum cylinder were evaluated. The results show that the strength and stiffness of each part with complicated geometry well satisfy the design requirements. However, the maximum stress and rigidity of the different cylinders were found to be far below the yield strength of the material. We found that the structural optimization of the vacuum cylinder reduced the volume and weight by 28.72% and 26.87% .respectively.The structure-optimized cylinder and its major parts were again modeled and simulated in finite element method.The simulated results show that the main parts of the optimized vacuum chamber satisfy the technical requirements.%针对核聚变装置中的中性束注入器真空筒体的工作要求,完成了综合测试台真空筒体的结构设计,并对真空简体各主要部件进行了受力计算和静力分析.分析结果表明,真空筒体各主要部件均满足设计要求,且筒体各段的强度和刚度均远小于所选材料的屈服极限,存在材料浪费.据此,在不改变材料的基础上,进一步对真空简体进行了结构优化设计,优化后真空筒体重量和体积分别减少28.72%和26.87%,再次模拟分析表明,优化后真空筒体的各主要部件均达到了性能要求.该分析优化方法为复杂模型的优化设计提供参考.

  16. Key Materials and Micro-Stack Systems of Single Chamber Solid Oxide Fuel Cells%单气室固体氧化物燃料电池关键材料与微堆系统

    Institute of Scientific and Technical Information of China (English)

    吕喆; 魏波; 田彦婷; 王志红; 苏文辉

    2011-01-01

    单气室固体氧化物燃料电池(SC-SOFC)是一种与传统的双气室结构燃料电池不同的新型燃料电池.SC-SOFC的阴极和阳极都暴露在单一气室中,在工作时通入含有燃料和氧化剂的混合气体,利用阳极和阴极的选择催化作用实现发电.SC-SOFC具有结构简单、无需密封、易于进行堆叠等很多独特的优点.本文介绍了SC-SOFC近期的研究进展,内容包括工作原理的介绍、SC-SOFC的关键材料选择与研究现状、影响SC-SOFC运行的主要因素的讨论,以及微堆(电池组)系统结构设计和试验等.着重介绍了本课题组在SC-SOFC的研究工作,包括对复合阴极材料、Ni修饰氧化物阳极的研究,以及星型和阵列式等多种新型SC-SOFC微堆结构设计与实验等.最后,基于对其优缺点的分析,展望了SC-SOFC各种潜在的应用.%Single chamber solid oxide fuel cell (SC-SOFC) is different from the conventional solid oxide fuel cell with dual gas chamber structure.Both cathode and anode of SC-SOFC are exposed to the only one gas chamber.Mixed gas containing fuel and oxidant is fed during operation and it can generate electric energy by the selectively catalytic activities of cathode and anode.SC-SOFC has many particular advatages, such as more simple structure, eliminating the need for sealing and easy stacking etc.In this paper, the recent research advances of SC-SOFC are reviewed, including brief introduction of operational principle of SC-SOFC, the selection of key materials for SC-SOFC, the discussion of main influencing factors on SC-SOFC, as well as the design and test of micro-stack (battery) system.The investigation results on SC-SOFC of our research group are highlighted, including composite cathode, oxide anode with Ni modification, and some novel designs for SC-SOFC micro stacks, such as star-type and array-type stacks, and so on.Finally, an outlook about the potential applications of SC-SOFC is given according to the analysis of

  17. Discussion on the Application of Cloud Chamber Air Sampling Detecting System in Power Sites%浅谈云雾室型空气采样探测系统在电力场所的应用

    Institute of Scientific and Technical Information of China (English)

    赵霞

    2012-01-01

    本文通过分析目前所使用的火灾报警器的优缺点,突出了极早期火灾探测器在电力场所的防火优势,并对云雾室型极早期探测器探测依据、原理及应用案例进行了介绍,指出IFD火灾极早期探测系统具有极高的灵敏度及调节范围,采用主动的采样方式进行探测,功能更加全面,性能更加可靠,使用更加安全,维护更加方便。%Through analyzing the advantages and disadvantages of the fire- alarms used in present, this paper lays stress on the superiority of very early fire detector in power sites in the aspect of fire prevention, and introduces the basis, principle and application cases of cloud chamber very early fire detector. It points out that IFD very early fire detecting system has high sensitivity and large range of accommodation, which uses active sampling pattern to detect, therefore the function is more comprehensive, the performance is more reliable, the application is safer and the maintenance is more convenient.

  18. Low-Cost, High-Performance Combustion Chamber

    Science.gov (United States)

    Fortini, Arthur J.

    2015-01-01

    Ultramet designed and fabricated a lightweight, high-temperature combustion chamber for use with cryogenic LOX/CH4 propellants that can deliver a specific impulse of approx.355 seconds. This increase over the current 320-second baseline of nitrogen tetroxide/monomethylhydrazine (NTO/MMH) will result in a propellant mass decrease of 55 lb for a typical lunar mission. The material system was based on Ultramet's proven oxide-iridium/rhenium architecture, which has been hot-fire tested with stoichiometric oxygen/hydrogen for hours. Instead of rhenium, however, the structural material was a niobium or tantalum alloy that has excellent yield strength at both ambient and elevated temperatures. Phase I demonstrated alloys with yield strength-to-weight ratios more than three times that of rhenium, which will significantly reduce chamber weight. The starting materials were also two orders of magnitude less expensive than rhenium and were less expensive than the C103 niobium alloy commonly used in low-performance engines. Phase II focused on the design, fabrication, and hot-fire testing of a 12-lbf thrust class chamber with LOX/CH4, and a 100-lbf chamber for LOX/CH4. A 5-lbf chamber for NTO/MMH also was designed and fabricated.

  19. Thin wall vacuum reaction chamber for neutron measurement

    International Nuclear Information System (INIS)

    A thin wall (3 mm) stainless steel vacuum reaction chamber has been designed, fabricated and installed in the K500 superconducting beam hall at VECC for the in-beam experiment. The chamber is spherical in shape, with inner diameter 1010 mm, having three independent sections. The middle segment is fixed to the beam line, whereas the two hemispherical sections are removable type with the help of hydraulic trolleys. This specific design facilitates almost 360 degree access of the chamber for setting up an experiment. The typical vacuum ∼ 4 x 10-7 mbar is achieved by two 550 lit/sec air cooled turbo molecular pumps backed by two 35 m3/hr scroll pumps in ∼ 8 hours. PLC based control system has been developed for the operation of pumps. 12 rings are fabricated to mount detectors, each having 440 mm radius and separated by 30° from each other in polar angle. These rings are supported inside the chamber by two flanges placed along the beam line. These rings are properly calibrated in polar and azimuthal angles with respect to the centre of the chamber. (author)

  20. Calculation of longitudinal CSR impedance in curved chamber

    International Nuclear Information System (INIS)

    Coherent synchrotron radiation (CSR) fields are generated when a bunched beam moves along a curved trajectory. A new code, named CSRZ, was developed using finite difference method to calculate the longitudinal CSR impedance for a beam moving along a curved chamber. The method adopted in our code was originated by T. Agoh and K. Yokoya [1]. It solves the parabolic equation in the frequency domain in a curvilinear coordinate system. In our studies, the chamber has uniform rectangular crosssection along the beam trajectory, which is the same as that in [1]. But the curvature of the beam trajectory is freed, and then we can investigate the CSR impedance of a single or a series of bending magnets. The calculation results indicate that the shielding effect due to outer chamber wall can be well explained by a simple optical approximation model at high frequencies. With an approximation of a wiggling chamber inside a wiggler, the coherent wiggler radiation (CWR) impedance has also been studied. Due to chamber shielding, the CWR impedance exhibits narrow peaks at frequencies satisfying the resonant conditions. (author)

  1. A recording chamber for small volume slice electrophysiology.

    Science.gov (United States)

    Dondzillo, Anna; Quinn, Kevin D; Cruickshank-Quinn, Charmion I; Reisdorph, Nichole; Lei, Tim C; Klug, Achim

    2015-09-01

    Electrophysiological recordings from brain slices are typically performed in small recording chambers that allow for the superfusion of the tissue with artificial extracellular solution (ECS), while the chamber holding the tissue is mounted in the optical path of a microscope to image neurons in the tissue. ECS itself is inexpensive, and thus superfusion rates and volumes of ECS consumed during an experiment using standard ECS are not critical. However, some experiments require the addition of expensive pharmacological agents or other chemical compounds to the ECS, creating a need to build superfusion systems that operate on small volumes while still delivering appropriate amounts of oxygen and other nutrients to the tissue. We developed a closed circulation tissue chamber for slice recordings that operates with small volumes of bath solution in the range of 1.0 to 2.6 ml and a constant oxygen/carbon dioxide delivery to the solution in the bath. In our chamber, the ECS is oxygenated and recirculated directly in the recording chamber, eliminating the need for tubes and external bottles/containers to recirculate and bubble ECS and greatly reducing the total ECS volume required for superfusion. At the same time, the efficiency of tissue oxygenation and health of the section are comparable to standard superfusion methods. We also determined that the small volume of ECS contains a sufficient amount of nutrients to support the health of a standard brain slice for several hours without concern for either depletion of nutrients or accumulation of waste products. PMID:26203105

  2. Legacies of the bubble chamber

    International Nuclear Information System (INIS)

    Legacies are what we pass on to those who follow us, the foundations on which the next advances in our science are being made; the things by which we shall be remembered, recorded in learned journals, written in the text books -food for the historians of science. This is not a summary, and it will draw no conclusions. It is a personal view which will look a little wider than the main physics results to include a mention of one or two of the technologies and methods handed on to both particle physics and other branches of sciences, a brief reference to bubble chamber pictures as aids in teaching, and a comment on the challenge now increasingly applied in the UK - and perhaps elsewhere -as a criterion for funding research: will it contribute to ''wealth creation''? (orig.)

  3. Explosion-induced combustion of hydrocarbon clouds in a chamber

    Energy Technology Data Exchange (ETDEWEB)

    Neuwald, P; Reichenbach, H; Kuhl, A L

    2001-02-06

    The interaction of the detonation of a solid HE-charge with a non-premixed cloud of hydro-carbon fuel in a chamber was studied in laboratory experiments. Soap bubbles filled with a flammable gas were subjected to the blast wave created by the detonation of PETN-charges (0.2 g < mass < 0.5 g). The dynamics of the combustion system were investigated by means of high-speed photography and measurement of the quasi-static chamber pressure.

  4. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  5. Properties of a commercial extrapolation chamber in beta radiation fields

    International Nuclear Information System (INIS)

    A commercial extrapolation chamber (PTW, Germany) was tested in different beta radiation fields and its properties investigated. Its usefulness for beta radiation calibration and dosimetry was demonstrated. The Beta Secondary Standard setup of the IPEN calibration laboratory was utilized. This system, developed by the Physikalisch-Tecknische Bundesanstalt, Brunswick (Germany) and manufactured by Buchler and Co., consists of a source stand, a control unit with timer and four interchangeable beta sources: 90Sr-90Y (1850 and 74 MBq), 204Tl (18,5 MBq) ionization current detection. The variable volume ionization chamber of cylindrical form is provided with different collecting electrodes of tissue equivalent material and Mylar entrance windows of different thickesses

  6. Characterization of a free air ionization chamber for low energies

    International Nuclear Information System (INIS)

    Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition. (author)

  7. Repatriation of Gamma Chambers Exported by India

    International Nuclear Information System (INIS)

    The Board of Radiation and Isotope Technology (BRIT) is engaged in the production and supply of laboratory gamma chambers. The gamma chambers are self-shielded devices in which a number of 60Co source pencils placed in a cylindrical cage. The gamma chambers are type approved as a device and a transportation package separately by the Atomic Energy Regulatory Board. BRIT has exported number of such gamma chambers. For some of the gamma chambers, the type approval validity period is over and can no longer be transported. Hence, the radiation sources need to be transferred to a type approved package before transportation. BRIT has decommissioned five such gamma chambers so far and sources have been repatriated back to India. (author)

  8. Neutron-chamber detectors and applications

    International Nuclear Information System (INIS)

    Detector applications in Nuclear Safeguards and Waste Management have included measuring neutrons from fission and (alpha,n) reactions with well-moderated neutron proportional counters, often embedded in a slab of polyethylene. Other less-moderated geometries are useful for detecting both bare and moderated fission-source neutrons with good efficiency. The neutron chamber is an undermoderated detector design comprising a large, hollow, polyethylene-walled chamber containing one or more proportional counters. Neutron-chamber detectors are relatively inexpensive; can have large apertures, usually through a thin chamber wall; and offer very good detection efficiency per dollar. Neutron-chamber detectors have also been used for monitoring vehicles and for assaying large crates of transuranic waste. Our Monte Carlo calculations for a new application (monitoring low-density waste for concealed plutonium) illustrate the advantages of the hollow-chamber design for detecting moderated fission sources. 9 refs., 6 figs., 2 tabs

  9. Technology developments for thrust chambers of future launch vehicle liquid rocket engines

    Science.gov (United States)

    Immich, H.; Alting, J.; Kretschmer, J.; Preclik, D.

    2003-08-01

    In this paper an overview of recent technology developments for thrust chambers of future launch vehicle liquid rocket engines at Astrium, Space Infrastructure Division (SI), is shown. The main technology. developments shown in this paper are: Technologies Technologies for enhanced heat transfer to the coolant for expander cycle engines Advanced injector head technologies Advanced combustion chamber manufacturing technologies. The main technologies for enhanced heat transfer investigated by subscale chamber hot-firing tests are: Increase of chamber length Hot gas side ribs in the chamber Artificially increased surface roughness. The developments for advanced injector head technologies were focused on the design of a new modular subscale chamber injector head. This injector head allows for an easy exchange of different injection elements: By this, cost effective hot-fire tests with different injection element concepts can be performed. The developments for advanced combustion chamber manufacturing technologies are based on subscale chamber tests with a new design of the Astrium subscale chamber. The subscale chamber has been modified by introduction of a segmented cooled cylindrical section which gives the possibility to test different manufacturing concepts for cooled chamber technologies by exchanging the individual segments. The main technology efforts versus advanced manufacturing technologies shown in this paper are: Soldering techniques Thermal barrier coatings for increased chamber life. A new technology effort is dedicated especially to LOX/Hydrocarbon propellant combinations. Recent hot fire tests on the subscale chamber with Kerosene and Methane as fuel have already been performed. A comprehensive engine system trade-off between the both propellant combinations (Kerosene vs. Methane) is presently under preparation.

  10. Streamlined Calibration of the ATLAS Muon Spectrometer Precision Chambers

    CERN Document Server

    Levin, DS; The ATLAS collaboration; Dai, T; Diehl, EB; Ferretti, C; Hindes, JM; Zhou, B

    2009-01-01

    The ATLAS Muon Spectrometer is comprised of nearly 1200 optically Monitored Drifttube Chambers (MDTs) containing 354,000 aluminum drift tubes. The chambers are configured in barrel and endcap regions. The momentum resolution required for the LHC physics reach (dp/p = 3% and 10% at 100 GeV and 1 TeV) demands rigorous MDT drift tube calibration with frequent updates. These calibrations (RT functions) convert the measured drift times to drift radii and are a critical component to the spectrometer performance. They are sensitive to the MDT gas composition: Ar 93%, CO2 7% at 3 bar, flowing through the detector at arate of 100,000 l hr−1. We report on the generation and application of Universal RT calibrations derived from an inline gas system monitor chamber. Results from ATLAS cosmic ray commissioning data are included. These Universal RTs are intended for muon track reconstuction in LHC startup phase.

  11. A Bragg curve ionization chamber for acceleration mass spectrometry

    International Nuclear Information System (INIS)

    An ionization chamber based on the Bragg curve spectrometry method to be used as the final detector in a accelerator mass spectrometry system is described. The first tests with a Cl beam give energy resolution of 1% and Z resolving power of 72 at Z=17

  12. Device for graded exercising of rats in pressure chamber

    Science.gov (United States)

    Yurova, K. S.; Potabenko, V. M.

    1983-11-01

    A device was developed that would permit rapid immersion of animals into water in order to exercise (swim) at different stages of high pressure and to remove them from water just as rapidly without lowering pressure in the chamber. This device permits investigation of metabolic processes, enzyme activity and the role of the adrenosympathetic system in swimming animals.

  13. Chamber for uniaxial pressure application at low temperatures

    International Nuclear Information System (INIS)

    A chamber for alignment of low temperature ferroelastic domains in crystals by the use of uniaxial stress was built. The system allows the use of EPR and optical techniques, as well as X-ray irradiation at temperatures as low as 77K. (Author)

  14. Compatibility results of some diagnostic ionization chambers

    International Nuclear Information System (INIS)

    The most important task of the National Laboratory for Metrology of the Ionizing Radiations at the Institute for Radiation Protection and Dosimetry - LNMRI/IRD-CNEN/MCT is to realize and maintain the legal units in compliance with the International System of Units - Si and disseminate them, above all within the framework of legal and scientific metrology. The LNMRI/IRD thus is on top of the metrological hierarchy in Brazil. Calibration certificates issued is the document that was result of the calibrations, that is, the instrument was calibrated and now it is traceable to national standards. Groups of a similar model of the ion chambers design specific for using at conventional diagnostic dosimetric, attenuated and no attenuated and dental applications, are placed under similar calibration condition at the LNMRI/IRD. The main objective is to observe how is the compatibilities' measurements obtained through 10 equipment set dedicated for clinical dosimetry, and how are the dispersion conclusion for these. (author)

  15. Bubble chamber: Omega production and decay

    CERN Multimedia

    1973-01-01

    This image is taken from one of CERN's bubble chambers and shows the decay of a positive kaon in flight. The decay products of this kaon can be seen spiraling in the magnetic field of the chamber. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that has been heated to boiling point.

  16. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    1974-01-01

    To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).

  17. IFE Chamber Technology - Status and Future Challenges

    International Nuclear Information System (INIS)

    Significant progress has been made on addressing critical issues for inertial fusion energy (IFE) chambers for heavy-ion, laser and Z-pinch drivers. A variety of chamber concepts are being investigated including drywall (currently favored for laser IFE), wetted-wall (applicable to both laser and ion drivers), and thick-liquid-wall (favored by heavy ion and z-pinch drivers). Recent progress and remaining challenges in developing IFE chambers are reviewed

  18. Construction and performance of large flash chambers

    International Nuclear Information System (INIS)

    The construction and performance of 12' x 12' flash chambers used in a 340 ton neutrino detector under construction at Fermilab is described. The flash chambers supply digital information with a spatial resolution of 0.2'', and are used to finely sample the shower development of the reaction products of neutrino interactions. The flash chambers are easy and inexpensive to build and are electronically read out

  19. Drift chamber tracking with neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed.

  20. Vapor wall deposition in Teflon chambers

    OpenAIRE

    Zhang, X; R. H. Schwantes; R. C. McVay; H Lignell; M. M. Coggon; Flagan, R C; Seinfeld, J.H.

    2014-01-01

    Teflon chambers are ubiquitous in studies of atmospheric chemistry. Secondary organic aerosol (SOA) formation can be substantially underestimated owing to deposition of SOA-forming compounds to chamber walls. We present here an experimental protocol to constrain the nature of wall deposition of organic vapors in Teflon chambers. We measured the wall deposition rates of 25 oxidized organic compounds generated from the photooxidation of isoprene, toluene, α-pinene, and dodecan...

  1. Drift chamber tracking with neural networks

    International Nuclear Information System (INIS)

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed

  2. Characterization tests and application of special ionization chambers in standard mammography beams

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Cristiane J.C.; Caldas, Linda V.E., E-mail: cristianehonda@usp.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Silva, Jonas O., E-mail: jonas.silva@ufg.br [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Instituto de Fisica

    2015-07-01

    The most used instrument for quality assurance programs in mammography beams is the ionization chamber. At the Calibration Laboratory of IPEN three different ionization chambers were recently designed and assembled for dosimetry in standard mammography beams. These ionization chambers are parallel plate chambers, with different geometries. The objective of this work was to study the performance of all three ionization chambers in relation to a commercial one. The established standard beams at an industrial X-ray system Pantak-Seifert were used for the characterization tests of the ionization chambers as short- and medium-term stability, saturation curves, polarity effect, ion collection efficiency, response linearity and angular dependence. All of the results obtained were within the limits recommended by the international standards IEC 61674 and IEC 60731. (author)

  3. Characterization tests and application of special ionization chambers in standard mammography beams

    International Nuclear Information System (INIS)

    The most used instrument for quality assurance programs in mammography beams is the ionization chamber. At the Calibration Laboratory of IPEN three different ionization chambers were recently designed and assembled for dosimetry in standard mammography beams. These ionization chambers are parallel plate chambers, with different geometries. The objective of this work was to study the performance of all three ionization chambers in relation to a commercial one. The established standard beams at an industrial X-ray system Pantak-Seifert were used for the characterization tests of the ionization chambers as short- and medium-term stability, saturation curves, polarity effect, ion collection efficiency, response linearity and angular dependence. All of the results obtained were within the limits recommended by the international standards IEC 61674 and IEC 60731. (author)

  4. An experimental setup for the study of the steady air flow in a diesel engine chamber

    OpenAIRE

    Montanero José María; Marcos Alberto; Castilla Alejandro; Vega Emilio José; Fernández Joaquín; Barrio Raúl

    2012-01-01

    We present an experimental setup for studying the steady air flow in a diesel engine chamber. An engine block containing the inlet manifold was placed on a test bench. A steady air stream crossed the inlet manifold and entered a glass chamber driven by a fan. A PIV system was set up around the bench to measure the in-chamber flow. An air spray gun was used as seed generator to producing sub-millimeter droplets, easily dragged by the air stream. Images of the in-flow chamber were acquired in t...

  5. Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields

    International Nuclear Information System (INIS)

    Purpose: The magnetic fields of an integrated MR-Linac system will alter the paths of electrons that produce ions in the ionization chambers. The dose response of selected ion chambers is evaluated in the presence of varying transverse and longitudinal magnetic fields. The investigation is useful in calibration of therapeutic x-ray beams associated with MR-Linac systems. Methods: The Monte Carlo code PENELOPE was used to model the irradiation of NE2571, and PR06C ionization chambers in the presence of a transverse and longitudinal (with respect to the photon beam) magnetic fields of varying magnitude. The long axis of each chamber was simulated both parallel and perpendicular to the incident photon beam for each magnetic field case. The dose deposited in each chamber for each case was compared to the case with zero magnetic field by means of a ratio. The PR06C chamber's response was measured in the presence of a transverse magnetic field with field strengths ranging from 0.0 to 0.2 T to compare to simulated results. Results: The simulations and measured data show that in the presence of a transverse magnetic field there is a considerable dose response (maximum of 11% near 1.0 T in the ion chambers investigated, which depends on the magnitude of magnetic field, and relative orientation of the magnetic field, radiation beam, and ion chamber. Measurements made with the PR06C chamber verify these results in the region of measurement. In contrast, a longitudinal magnetic field produces only a slight increase in dose response (2% at 1.5 T) that rises slowly with increasing magnetic field and is seemingly independent of chamber orientation. Response trends were similar for the two ion chambers and relative orientations considered, but slight variations are present from chamber to chamber. Conclusions: Care must be taken when making ion chamber measurements in a transverse magnetic field. Ion chamber responses vary not only with transverse field strength, but with chamber

  6. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  7. The Mark II Vertex Drift Chamber

    International Nuclear Information System (INIS)

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO2 mixtures are presented. 10 refs., 12 figs., 1 tab

  8. Cylindrical ionization chamber with compressed krypton

    International Nuclear Information System (INIS)

    A cylindrical ionization chamber with a grid is used to search for double positron decay and atomic electron conversion to a positron in 78Kr. Krypton is the working gas material of the chamber. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. The energy resolution is 2.1% for an energy of 1.84 MeV (the source of γ-quanta is 88Y) when the chamber is filled with a mixture of Kr+0.2% H2 under a pressure of 25 atm

  9. D0 central tracking chamber performance studies

    International Nuclear Information System (INIS)

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e- events

  10. D0 central tracking chamber performance studies

    Energy Technology Data Exchange (ETDEWEB)

    Pizzuto, D.

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an R{Phi} tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against {gamma} {yields} e {sup +} e{sup {minus}} events.

  11. High-repetition-rate hydrogen chamber: Preliminary studies

    International Nuclear Information System (INIS)

    This report is a conclusion to the tests realised with an experimental bubbles chamber in view to study the possibilities to increase the repetition rate. The more important parameters (the evolution of the bubbles, the expansion system) are considered in a theoretical way. Then the hardware is described. To end, experimental results are compared with the first evaluations. The calculations and the experimentation are against an oscillation system for the expansion. A system with a locking is to he considered. (authors)

  12. 基于VISA和Mint的微波暗室自动测量系统实现%Implemenation of the Microwave Anechoic Chamber Automatic Measuring System Based on VISA and Mint

    Institute of Scientific and Technical Information of China (English)

    李瑞阳; 韦高; 韩旭; 符礼

    2013-01-01

    建立了一套基于VISA和Mint的微波暗室自动测量系统,通过计算机控制矢网和转台以实现高效率的天线与RCS的微波暗室自动测量.在Visual C++开发环境下,运用多线程技术将矢网和转台结合,同时采用VISA和SCPI命令实现矢网的自动控制,采用Mint ActiveX控件技术实现转台的自动控制,该方法易于实现矢网与转台的高效同步.实测表明,该系统操作方便,测量效率、测量精度与自动化程度较高,所采用的控制方法有着较好的通用性和可拓展性,具有广阔的应用前景.%In order to realize efficient automatic antenna and RCS measurement,a microwave anechoic chamber automatic measurement system has been established,using the computer to control the vector network analyzer and the test turntable.In visual C++development environment,the multithread technology is used to combine the vector network analyzer with the test turntable.The vector network analyzer is auto-controlled by VISA and SCPI command ; the test turntable is auto-controlled by Mint ActiveX control technology.The methods are easy to efficiently synchronize the two devices.The actual measurement shows that the system is easy to control,and has high measurement efficiency,high precision,and high automaticity.The controlling method has broad application prospects for it has good universality and is easy to expand.

  13. In Vitro Culturing and Live Imaging of Drosophila Egg Chambers: A History and Adaptable Method.

    Science.gov (United States)

    Peters, Nathaniel C; Berg, Celeste A

    2016-01-01

    The development of the Drosophila egg chamber encompasses a myriad of diverse germline and somatic events, and as such, the egg chamber has become a widely used and influential developmental model. Advantages of this system include physical accessibility, genetic tractability, and amenability to microscopy and live culturing, the last of which is the focus of this chapter. To provide adequate context, we summarize the structure of the Drosophila ovary and egg chamber, the morphogenetic events of oogenesis, the history of egg-chamber live culturing, and many of the important discoveries that this culturing has afforded. Subsequently, we discuss various culturing methods that have facilitated analyses of different stages of egg-chamber development and different types of cells within the egg chamber, and we present an optimized protocol for live culturing Drosophila egg chambers.We designed this protocol for culturing late-stage Drosophila egg chambers and live imaging epithelial tube morphogenesis, but with appropriate modifications, it can be used to culture egg chambers of any stage. The protocol employs a liquid-permeable, weighted "blanket" to gently hold egg chambers against the coverslip in a glass-bottomed culture dish so the egg chambers can be imaged on an inverted microscope. This setup provides a more buffered, stable, culturing environment than previously published methods by using a larger volume of culture media, but the setup is also compatible with small volumes. This chapter should aid researchers in their efforts to culture and live-image Drosophila egg chambers, further augmenting the impressive power of this model system. PMID:27557572

  14. Resistive Plate Chambers commissioning and performance results for 2015

    CERN Document Server

    CMS Collaboration

    2016-01-01

    The Resistive Plate Chamber (RPC) detector system at the Compact Muon Solenoid experiment at the LHC confers robustness and redundancy to the muon trigger. During the first long shutdown of the LHC (2013-2014) the CMS muon RPC system has been upgraded with 144 double-gap chambers on the forth forward stations. A total of 1056 double-gap chambers cover the pseudo-rapidity region up to 1.6. The main detector parameters are constantly and closely monitored to achieve operational stability and high quality data in the harsh conditions of the second run period of the LHC (13 TeV and 25 ns bunch spacing). Resistive Plate Chambers (RPC) performance results for 2015 with pp collisions at 13 TeV are presented. These results include the occupancy, efficiency of newly installed detectors after applying new working point, history plots for the RPC relevant variables such as: Cluster Size, Efficiency, percentage of inactive detector during operation and Rates and overall system noise. RPC variables are studied as funct...

  15. Nonlinear saturation of thermoacoustic oscillations in annular combustion chambers

    Science.gov (United States)

    Ghirardo, Giulio; Juniper, Matthew

    2014-11-01

    Continuous combustion systems such as aeroplane engines can experience self-sustained pressure oscillations, called thermoacoustic oscillations. Quite often the combustion chamber is rotationally symmetric and confined between inner and outer walls, with a fixed number of burners equispaced along the annulus, at the chamber inlet. We focus on thermoacoustic oscillations in the azimuthal direction, and discuss the nonlinear saturation of the system towards 2 types of solutions: standing waves (with velocity and pressure nodes fixed in time and in space) and spinning waves (rotating waves, in clockwise or anti-clockwise direction). We neglect the effect of the transverse velocity oscillating in the azimuthal direction in the combustion chamber, and focus the model on the nonlinear effect that the longitudinal velocity, just upstream of each burner, has on the fluctuating heat-release response in the chamber. We present a low-order analytical framework to discuss the stability of the 2 types of solutions. We discuss how the stability and amplitudes of the 2 solutions depend on: 1) the acoustic damping in the system; 2) the number of injectors equispaced in the annulus; 3) the nonlinear response of the flames.

  16. Contamination Control Assessment of the World's Largest Space Environment Simulation Chamber

    Science.gov (United States)

    Snyder, Aaron; Henry, Michael W.; Grisnik, Stanley P.; Sinclair, Stephen M.

    2012-01-01

    The Space Power Facility s thermal vacuum test chamber is the largest chamber in the world capable of providing an environment for space simulation. To improve performance and meet stringent requirements of a wide customer base, significant modifications were made to the vacuum chamber. These include major changes to the vacuum system and numerous enhancements to the chamber s unique polar crane, with a goal of providing high cleanliness levels. The significance of these changes and modifications are discussed in this paper. In addition, the composition and arrangement of the pumping system and its impact on molecular back-streaming are discussed in detail. Molecular contamination measurements obtained with a TQCM and witness wafers during two recent integrated system tests of the chamber are presented and discussed. Finally, a concluding remarks section is presented.

  17. Integrated Chamber Design for the Laser Inertial Fusion Energy (LIFE) Engine

    International Nuclear Information System (INIS)

    The Laser Inertial Fusion Energy (LIFE) concept is being designed to operate as either a pure fusion or hybrid fusion-fission system. A key component of a LIFE engine is the fusion chamber subsystem. The present work details the chamber design for the pure fusion option. The fusion chamber consists of the first wall and blanket. This integrated system must absorb the fusion energy, produce fusion fuel to replace that burned in previous targets, and enable both target and laser beam transport to the ignition point. The chamber system also must mitigate target emissions, including ions, x-rays and neutrons and reset itself to enable operation at 10-15 Hz. Finally, the chamber must offer a high level of availability, which implies both a reasonable lifetime and the ability to rapidly replace damaged components. An integrated LIFE design that meets all of these requirements is described herein.

  18. Chamber Music's Lesson in Performing Confidence.

    Science.gov (United States)

    Stubbs, Darrel W.

    1983-01-01

    Chamber music has the advantage of offering the student maximum exposure as an individual performer. The absence of a conductor means that the student assumes the role of interpreter, thereby gaining musical maturity. For these reasons, curriculum hours should be more evenly divided between chamber music and larger ensembles. (CS)

  19. The Drift Chambers Of The Nomad Experiment

    CERN Document Server

    Anfreville, M G; Authier, M; Baldisseri, Alberto; Banner, M; Besson, N; Bouchez, J; Castera, A; Cloué, O; Dumarchez, J; Dumps, Ludwig; Gangler, E; Gosset, J; Hagner, C; Jollec, C; Lachaud, C; Letessier-Selvon, A A; Lévy, J M; Linssen, Lucie; Meyer, J P; Ouriet, J P; Passerieux, J P; Pédrol, T; Placci, Alfredo; Poinsignon, J; Popov, B; Rathouit, P; Schahmaneche, K; Stolarczyk, T; Urós, V; Vannucci, François; Vo, M K; Zaccone, Henri

    2002-01-01

    We present a detailed description of the drift chambers used as an active target and a tracking device in the NOMAD experiment at CERN. The main characteristics of these chambers are a large area, a self supporting structure made of light composite materials and a low cost. A spatial resolution of 150 microns has been achieved with a single hit efficiency of 97%.

  20. Space Power Facility Reverberation Chamber Calibration Report

    Science.gov (United States)

    Lewis, Catherine C.; Dolesh, Robert J.; Garrett, Michael J.

    2014-01-01

    This document describes the process and results of calibrating the Space Environmental Test EMI Test facility at NASA Plum Brook Space Power Facility according to the specifications of IEC61000-4-21 for susceptibility testing from 100 MHz to 40 GHz. The chamber passed the field uniformity test, in both the empty and loaded conditions, making it the world's largest Reverberation Chamber.

  1. 瑞敏系列和TURE TEST系列斑贴试剂检测结果比较%Comparison of Patch Test Results Useing IQ Chamber System and TURE TEST

    Institute of Scientific and Technical Information of China (English)

    曹晓佳; 张理涛

    2012-01-01

    目的 分析瑞敏系列(R)和TURE TEST系列(T)斑贴试剂检测结果及一致性.方法 分别用这两个系列斑贴试剂检测196例慢性湿疹和接触性皮炎患者,对其检测结果进行比较.结果 瑞敏系列和TURE TEST系列斑贴试剂对各变应原检测阳性率不完全相同,它们检测常见变应原种类均与国内已有报道类似;两个系列中相同的16种变应原的检测反应强度一致性较好,检测的阳性率差异无统计学意义(P>0.05).结论 两个系列斑贴试剂的一致性较好,临床上可根据患者情况选择应用.%Objective To study the patch test reactions and the concordance of IQ chamber system (R) and TRUE Test (T). Methods Two different series patch test reagents were performed to detect 196 patients with chronic eczema and contact dermatitis, then the results were compared. Results The positive rates of every allergen were not completely the same,the most common allergens known from two series reagents were similar with the past reported of inland. The strength of allergic reaction of the same 16 allergens of two series reagents had good consistence and the positive rates of R and T were statistically insignificance. Conclusion This two different patch test series exhibited a high level of consistence, and doctors could choose suitable series according to the conditions of patients in clinic.

  2. Wet drift chambers for precise luminosity

    International Nuclear Information System (INIS)

    A set of high-precision compact drift chambers has been a vital component of the OPAL luminosity monitor since the start of data-taking at LEP. They were augmented in 1992 by the addition of Small Angle Reference Chambers with a very similar design to the original chamber. The performance of the chambers is reviewed, highlighting both the importance of using polyalkylene glycol (Breox) to maintain a uniform and parallel electric field and the construction techniques used to sustain the required field strength. We describe some of the operating problems, with their solutions, and show how the chambers have been used in achieving a systematic error of 0.41% on the luminosity measurement. ((orig.))

  3. Compact ion chamber based neutron detector

    Science.gov (United States)

    Derzon, Mark S.; Galambos, Paul C.; Renzi, Ronald F.

    2015-10-27

    A directional neutron detector has an ion chamber formed in a dielectric material; a signal electrode and a ground electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; readout circuitry which is electrically coupled to the signal and ground electrodes; and a signal processor electrically coupled to the readout circuitry. The ion chamber has a pair of substantially planar electrode surfaces. The chamber pressure of the neutron absorbing material is selected such that the reaction particle ion trail length for neutrons absorbed by the neutron absorbing material is equal to or less than the distance between the electrode surfaces. The signal processor is adapted to determine a path angle for each absorbed neutron based on the rise time of the corresponding pulse in a time-varying detector signal.

  4. Air kerma strength calibration of 0.6 cc Farmer chamber for 192Ir HDR source

    International Nuclear Information System (INIS)

    One of the methods adopted by hospitals for the calibration of the HDR 192Ir source, in terms of Air Kerma Strength (AKS) is to use 0.6cc chamber at short source to chamber distances for measuring the air kerma rate at the chamber position and then compute the AKS using the appropriate correction factors. However, the 0.6 cc Farmer type chambers purchased by the users for the calibration of the HDR 192Ir source, are not generally provided with an HDR 192Ir calibration factor. With the result, many hospitals that have purchased the Farmer type chamber for the calibration of 192Ir HDR sources, use the 60Co calibration factor for this purpose. The use of 60Co calibration factor for the 192Ir HDR source would unnecessarily increase the uncertainty of the measured AKS. Again, because of the low chamber sensitivity, hospitals often use, source to chamber distances as small as a few cm for calibrating the 192Ir HDR source. In the absence of a rigid source-chamber positioning system, this can lead to several percent errors in AKS determination. Also, hospitals often don't take into account corrections for the room scatter or the fluence non-uniformity across the chamber, which further increase the uncertainty of the measured AKS

  5. Chamber and target technology development for inertial fusion energy

    Energy Technology Data Exchange (ETDEWEB)

    Abdou, M; Besenbruch, G; Duke, J; Forman, L; Goodin, D; Gulec, K; Hoffer, J; Khater, H; Kulcinsky, G; Latkowski, J F; Logan, B G; Margevicious, B; Meier, W R; Moir, R W; Morley, N; Nobile, A; Payne, S; Peterson, P F; Peterson, R; Petzoldt, R; Schultz, K; Steckle, W; Sviatoslavsky, L; Tillack, M; Ying, A

    1999-04-07

    Fusion chambers and high pulse-rate target systems for inertial fusion energy (IFE) must: regenerate chamber conditions suitable for target injection, laser propagation, and ignition at rates of 5 to 10 Hz; extract fusion energy at temperatures high enough for efficient conversion to electricity; breed tritium and fuel targets with minimum tritium inventory; manufacture targets at low cost; inject those targets with sufficient accuracy for high energy gain; assure adequate lifetime of the chamber and beam interface (final optics); minimize radioactive waste levels and annual volumes; and minimize radiation releases under normal operating and accident conditions. The primary goal of the US IFE program over the next four years (Phase I) is to develop the basis for a Proof-of-Performance-level driver and target chamber called the Integrated Research Experiment (IRE). The IRE will explore beam transport and focusing through prototypical chamber environment and will intercept surrogate targets at high pulse rep-rate. The IRE will not have enough driver energy to ignite targets, and it will be a non-nuclear facility. IRE options are being developed for both heavy ion and laser driven IFE. Fig. 1 shows that Phase I is prerequisite to an IRE, and the IRE plus NIF (Phase II) is prerequisite to a high-pulse rate. Engineering Test Facility and DEMO for IFE, leading to an attractive fusion power plant. This report deals with the Phase-I R&D needs for the chamber, driver/chamber interface (i.e., magnets for accelerators and optics for lasers), target fabrication, and target injection; it is meant to be part of a more comprehensive IFE development plan which will include driver technology and target design R&D. Because of limited R&D funds, especially in Phase I, it is not possible to address the critical issues for all possible chamber and target technology options for heavy ion or laser fusion. On the other hand, there is risk in addressing only one approach to each technology

  6. Readout and quality control of the HADES drift chambers

    International Nuclear Information System (INIS)

    In the present thesis the readout concept of the drift chambers is studied and its integration into the HADES data-acquisition system described. Because of the many-stage trigger system and the high requirements on the speed of the system methods for the data reduction were developed. By this it is possible to read out from all 27,000 channels the data within 10 μs after the trigger. The data are within ∼40 ns after the signal of the second trigger stage further transmitted. In the framework of the studies for the monitoring of the drift chamber data, which are described in the second part of this thesis, by the applied method for the determination of the intrinsic resolution a distinct deterioration of the resolution of the chambers was observed from 120 μm in november 2001 to above 200 μm in september 2003. As cause for this at the one hand the changed calibration method was determined, which no more regards the transmission time of the signals, at the other hand a change of the drift velocity because of a non-optimal high voltage. The method for the determination of the physical center of the chambers allows a statement on the position of the chambers relatively to the required position. The shifts along the x-axis found thereby agree for a part of the sectors with the values for the shift of the target determined in the framework of the alignment. For the other sectors additional shifts by 2 to 6 cm result

  7. Resistive plate chambers in positron emission tomography

    Science.gov (United States)

    Crespo, Paulo; Blanco, Alberto; Couceiro, Miguel; Ferreira, Nuno C.; Lopes, Luís; Martins, Paulo; Ferreira Marques, Rui; Fonte, Paulo

    2013-07-01

    Resistive plate chambers (RPC) were originally deployed for high energy physics. Realizing how their properties match the needs of nuclear medicine, a LIP team proposed applying RPCs to both preclinical and clinical positron emission tomography (RPC-PET). We show a large-area RPC-PET simulated scanner covering an axial length of 2.4m —slightly superior to the height of the human body— allowing for whole-body, single-bed RPC-PET acquisitions. Simulations following NEMA (National Electrical Manufacturers Association, USA) protocols yield a system sensitivity at least one order of magnitude larger than present-day, commercial PET systems. Reconstruction of whole-body simulated data is feasible by using a dedicated, direct time-of-flight-based algorithm implemented onto an ordered subsets estimation maximization parallelized strategy. Whole-body RPC-PET patient images following the injection of only 2mCi of 18-fluorodesoxyglucose (FDG) are expected to be ready 7 minutes after the 6 minutes necessary for data acquisition. This compares to the 10-20mCi FDG presently injected for a PET scan, and to the uncomfortable 20-30minutes necessary for its data acquisition. In the preclinical field, two fully instrumented detector heads have been assembled aiming at a four-head-based, small-animal RPC-PET system. Images of a disk-shaped and a needle-like 22Na source show unprecedented sub-millimeter spatial resolution.

  8. Design, construction and testing of a radon experimental chamber

    International Nuclear Information System (INIS)

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  9. The emulsion chamber technology experiment

    Science.gov (United States)

    Gregory, John C.

    1992-01-01

    Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

  10. Multiwire proportional chamber with a dielectric film. Numerical study

    International Nuclear Information System (INIS)

    Electrostatical properties of multiwire proportional chambers with a dielectric film of low conductivity are considered. Distribution of the electric field in the chamber was obtained using numerical methods. This allowed investigating the influence of various parameters (chamber geometry, voltage at the electrodes) on the chamber working characteristics. Dependence of the chamber amplitude characteristics on the counting rate was also obtained

  11. Vapor-barrier Vacuum Isolation System

    Science.gov (United States)

    Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)

    2014-01-01

    A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

  12. Endcap Muon Chamber Calibration and Monitoring Procedures in CMS

    CERN Document Server

    Vickey Boeriu, Oana

    2009-01-01

    The cathode strip chamber (CSC) system is one of the three types of muon detectors used in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). It consists of 468 chambers, with a total of $\\sim$218k strips and $\\sim$183k wires, placed onto two endcaps. Calibration tests which monitor the system stability, measure configuration constants that will be downloaded to electronics and calculate the calibration constants needed in the offline reconstruction - like crosstalk, gains, noise and connectivity - are performed regularly. The full chain of acquiring, analyzing and applying the calibration constants was successfully tested recently for the first time on the CSC system, using cosmic-ray data recorded during the Magnet Test and Cosmic Challenge (MTCC).

  13. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  14. Quantification of runoff in laboratory-scale chambers.

    Science.gov (United States)

    Isensee, A R; Sadeghi, A M

    1999-04-01

    Many of the variables that control transport of agrochemicals and pathogens in the field are difficult to measure because parameters such as slope, soil and plant conditions, and rainfall cannot be adequately controlled in the natural environment. This paper describes the design, construction, operation and performance of a system useful for studying surface transport of agrochemicals and pathogens under controlled slope, rainfall and soil conditions. A turntable is used to support and rotate 4 soil chambers under oscillating dripper units capable of simulating rainfall intensities from 1 to 43 mm h-1. Chambers (35 x 100 x 18 cm i.d.) were constructed with an adjustable height discharge gate to collect runoff and three drains to collect leachate. Height adjustable platforms were constructed to support and elevate the chambers up to 20% slope. The chambers were uniformly packed with 35 to 45 kg of soil (bulk density 1.18-1.27 g cm-3) and initially saturated with two low intensity rain events. The coefficient of variation of the rainfall delivery over a range of 5 to 43 mm h-1 averaged 7.5%. An experiment to determine the variability between chambers in runoff amount and uniformity indicated that at least one runoff-equilibration cycle is needed to obtain steady state conditions for conducting runoff transport evaluations. Another experiment conducted to evaluate atrazine [2-chloro-4-(ethylamino)-6-(isopropylamino)-s-triazine] runoff under simulated crop-residue covered vs bare soil conditions indicated six times more runoff from bare than crop residue covered soil. The system is capable of precise application of simulated rain, the simultaneous collection of runoff and leachate at slopes up to 20% and can be easily modified to meet a wide range of research parameters. PMID:10101845

  15. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  16. Making MUSIC: A multiple sampling ionization chamber

    Science.gov (United States)

    Shumard, B.; Henderson, D. J.; Rehm, K. E.; Tang, X. D.

    2007-08-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. × 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction.

  17. Liquid-argon cylindrical pulsed ionization chamber

    International Nuclear Information System (INIS)

    A liquid-argon cylindrical ionization chamber with a working volume of 200 cm2 is described. The chamber anode is made of stainless steel in the form of a hollow cylinder 30 mm in diameter and 140 mm in length. A beryllium bronze wire in diameter of 0.1 mm and at a spacing of 1 mm is used for winding the chamber screen grid. The chamber cathode is a brass thin-walled cylinder having an internal diameter of 56 mm and a height of 156 mm. The cathode-grid gap is 10 mm, the cathode-case gap is 2 mm. A 0.5 l cooling bath filled with liquid nitrogen is used to refrigirate the chamber. The chamber is evacuated to about 10-5 mm Hg. The total concentration of electronegative impurities in argon does not exceed 6x10-9. Dependences of the chamber counting and amplitude responses, on the cathode voltage under irradiation with γ-quanta at energies of 0.898 MeV and 1.836 MeV are given. The value of the energy resolution was evaluated by differentiating the high-energy edge of the Compton spectrum. The total width at a peak half-height constitutes 5% for an electron energy of 1.612 MeV. To achieve better resolution of the chamber it is necessary to reduce preamplifier noises by three times, to increase the working gap of the chamber and decrease the grid-anode gap

  18. Making MUSIC: A multiple sampling ionization chamber

    International Nuclear Information System (INIS)

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction

  19. Efficiency Studies of the PHENIX Resistive Plate Chambers

    Science.gov (United States)

    Tate, Aric

    2012-10-01

    At Brookhaven National Laboratory the PHENIX experiment on the Relativistic Heavy Ion Collider (RHIC) studies polarized p+p collisions in an effort to better understand the contribution of sea quarks to the spin structure of the proton. To enable PHENIX to measure these contributions a trigger upgrade was needed to improve the ability of the data acquisition system to select single high transverse momentum muon events. A key component to the trigger upgrade was the addition of two stations of Resistive Plate Chambers (RPCs) in each muon arm. These chambers were installed and fully implemented prior to the last RHIC run. To ensure that the RPCs will continue to perform efficiently many tests have been done, both on the installed chambers and spare chambers on a cosmic test stand. An efficiency versus high voltage test was run with the cosmic stand as well as an efficiency versus threshold test to try and maximize efficiency without gaining noise. A noise versus threshold scan helped determine at what threshold the RPCs best perform. These tests help us to operate the RPCs at a high efficiency and low noise manner. The analysis and results of these tests will be presented.

  20. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Provetti Cunha

    2014-04-01

    Full Text Available Purpose: The aim of this study was to investigate possible predictive factors related to anterior chamber fibrin formation after vitreoretinal surgery in a large series of patients. Methods: The data of 185 eyes of 185 patients submitted to vitreoretinal surgery was reviewed. The following variables were evaluated: the postoperatively presence of fibrin, age, diabetes mellitus, the vitrectomy system gauge (20, 23 or 25 gauge, the type of vitreous substitute, the influence of prior surgical procedures and the combination with cataract extraction. To evaluate predictive factors for anterior chamber fibrin formation, univariate analysis was performed. A multivariate stepwise logistic regression model was adjusted to investigate factors associated with fibrin formation (p<0.05. Results: Fibrinoid anterior chamber reaction was found in 12 (6.4% patients. For multivariate logistic regression analysis, balanced salt solution (BSS, the chance of fibrin occurrence was 5 times greater (odds ratio 4.83, CI 95% 1.302 - 17.892; p=0.019, while combination with phacoemulsification increased the chance of fibrin formation by 20 times (odds ratio 20, CI 95% 2.480 - 161.347; p=0.005. No significant difference was found regarding other variables. Conclusion: Anterior chamber fibrin formation is an unwanted complication after vitreoretinal surgery. Factors such as combined performance of phacoemulsification and the use of balanced salt solution as a vitreous substitute may predispose the occurrence of this complication.