WorldWideScience

Sample records for chamber quality control

  1. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  2. Development of special ionization chambers for a quality control program in mammography

    International Nuclear Information System (INIS)

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  3. Quality Control Procedures Applied to the CMS Muon Chambers Built at CIEMAT

    International Nuclear Information System (INIS)

    In this document the quality control procedures applied to the CMS muon drift chambers built at CIEMAT are described. It includes a description of the high voltage and front electronics associated to the chambers. Every procedure is described with detail and a list of the more common problems and possible solutions is given. This document can be considered as a chamber test handbook for beginners. (Author) 3 refs

  4. Readout and quality control of the HADES drift chambers

    International Nuclear Information System (INIS)

    In the present thesis the readout concept of the drift chambers is studied and its integration into the HADES data-acquisition system described. Because of the many-stage trigger system and the high requirements on the speed of the system methods for the data reduction were developed. By this it is possible to read out from all 27,000 channels the data within 10 μs after the trigger. The data are within ∼40 ns after the signal of the second trigger stage further transmitted. In the framework of the studies for the monitoring of the drift chamber data, which are described in the second part of this thesis, by the applied method for the determination of the intrinsic resolution a distinct deterioration of the resolution of the chambers was observed from 120 μm in november 2001 to above 200 μm in september 2003. As cause for this at the one hand the changed calibration method was determined, which no more regards the transmission time of the signals, at the other hand a change of the drift velocity because of a non-optimal high voltage. The method for the determination of the physical center of the chambers allows a statement on the position of the chambers relatively to the required position. The shifts along the x-axis found thereby agree for a part of the sectors with the values for the shift of the target determined in the framework of the alignment. For the other sectors additional shifts by 2 to 6 cm result

  5. A special ionization chamber performance for the quality control in radiotherapy

    International Nuclear Information System (INIS)

    A special double-faced plane parallel ionization chamber, with inner electrodes of different materials was developed. Its use will be in quality control programs of X-rays equipment, radiotherapy level. This chamber was tested and calibrated in accordance with international recommendations, and it showed a satisfactory level of performance, mainly with regard to its use: the formation of a Tandem system for confirmation of half-value layers and effective energies in X-radiation beams, previously determined by the conventional method. In this developed system absorbers or any special set-ups are not necessary. The main advantages of this type of chamber are simple and quick measurements, that enable higher frequency of quality control tests. Moreover, the Tandem chamber presents low cost, and can be used with any commercial available electrometer. (author)

  6. Comparative study of ionization chambers of two different sensitive volumes for dose quality control of IMRT

    International Nuclear Information System (INIS)

    The aim of this work is to make a comparative study of ionization chambers with sensitive volume of 0.01 cm3 and 0.13 cm3 to evaluate the dose assurance for IMRT treatment. To perform this study, 20 IMRT planning were selected with small field size, and dose measurements have been performed in a low dose gradient region with both ionization chambers. These measurements were compared with data provided by the planning software. The analysis of measurements showed that both chambers can be used for IMRT quality control, because the variations found not exceed 4,5% of expected value and the chamber with a volume of 0.13 cm3 had better results. In this work, one can conclude that the chamber with sensitive volume of 0.13cm3 despite to have a larger volume, this chamber is more favorable for quality control of absolute dosimetry of IMRT, but no excluding the use of chamber with sensitive volume of 0.01cm3 which obtained satisfactory results. (author)

  7. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  8. Production and quality control of the Barrel RPC chambers of the CMS experiment

    CERN Document Server

    Piccolo, D; Cavallo, E; Colaleo, A; Iaselli, G; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pulgliese, G; Ranieri, A; Romano, F; Trentadue, R; Cavallo, N; Comunale, G; Fabozzi, F; Paolucci, P; Sciacca, C; Belli, G; De Vecchi, C; Guida, R; Ratti, S P; Riccardi, G; Torre, P; Vitulo, P; Ban, Y; Hong Tao Liu; Si Jin Quian; Yan Lin Ye; Jun Ying; Anguelov, T; Guenchev, V; Panev, B; Piperov, S; Sultanov, G G; Vankov, P; Dimitrov, A; Glushkov, I; Litov, L; Nasteva, I; Pavlov, B; Petkov, P

    2006-01-01

    Resistive Plate Chambers, working in avalanche mode, have been chosen as dedicated muon detector both in barrel and endcap region of the CMS experiment for their fast response and for their capability to be produced as tracking devices on large areas. The production of the barrel RPC chambers will be reported here with special enphasis on the quality control and on the acceptation criteria carried out during the production. Results of the tests with cosmic rays both in production and testing sites will be summerized putting in evidence the problems and the critical issues characterizing the different phases of the construction.

  9. Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level

    International Nuclear Information System (INIS)

    A tandem ionization chamber, developed at the Instituto de Pesquisas Energeticas e Nucleares (IPEN), for X radiation beams, radiotherapy level, was applied into a quality control program of the Calibration Laboratory of IPEN. This ionization chamber is composed by two ionization chambers, with a volume of 0.6 cm3 each one. Its inner plane-parallel electrodes and guard rings are made of different materials: one is made of aluminum and the other is made of graphite. Because of this difference in materials, the ionization chamber forms a tandem system. The relative response of the calibration factors of both sides of the chamber allows an easy verification of the X-ray beam qualities stability. The ionization chamber was submitted to some tests to verify the stability of its response: leakage current before and after exposure, repeatability and reproducibility. The performance of the ionization chamber was satisfactory. (author)

  10. Quality control results of the drift tubes for the ATLAS MDT-BIS chambers

    CERN Document Server

    Alexopoulos, T; Dris, M; Filippas, T; Gazis, E; Katsoufis, E; Maltezos, S; Savva, Panagiota S; Tsipolitis, G; Tzamariudaki, E; 2004 IEEE Nuclear Science Symposium And Medical Imaging Conference

    2004-01-01

    ATLAS (A Toroidal LHC ApparatuS) is a general purpose experiment, which will start its operation at the Large Hadron Collider (LHC) at CERN in 2007. The ATLAS detector is designed to study the products of proton-proton collisions at c.m.s. energies of up to 14 TeV. Three Greek Universities have taken the responsibility to construct 112 BIS-MDT (Barrel Inner Small) chambers using 29 000 drift tubes of 170 cm length and 3 cm diameter that have been quality tested before assembly. This work describes the Quality Assurance and Quality Control (QA_QC) procedures for the drift tubes, followed at the High Energy Physics Laboratory of the National Technical University of Athens, while emphasis is given on the obtained results for the above mentioned number of tubes.

  11. Quality control results of the drift tubes for the ATLAS MDT-BIS chambers

    Science.gov (United States)

    Alexopoulos, T.; Avramidou, R.; Dris, M.; Filippas, T. A.; Gazis, E. N.; Katsoufis, E.; Maltezos, S.; Savva, P.; Tsipolitis, G.; Tzamariudaki, E.

    2006-05-01

    ATLAS (A Toroidal LHC ApparatuS) is a general purpose experiment, which will start its operation at the Large Hadron Collider (LHC) at CERN in 2007. The ATLAS detector is designed to study the products of proton-proton collisions at c.m.s. energies of up to 14 TeV. Three Greek Universities have taken the responsibility to construct 112 BIS-MDT (Barrel Inner Small) chambers using 29 000 drift tubes of 170 cm length and 3 cm diameter that have been quality tested before assembly. This work describes the Quality Assurance and Quality Control (QA_QC) procedures for the drift tubes, followed at the High Energy Physics Laboratory of the National Technical University of Athens, while emphasis is given on the obtained results for the above mentioned number of tubes.

  12. Quality control for the first large areas of triple GEM chambers for the CMS endcaps

    CERN Document Server

    Tytgat, Michael

    2015-01-01

    The CMS GEM collaboration plans to equip the very forward muon system with triple GEM detectors that can withstand the environment of the high-luminosity LHC. This project is at the final stages of R and D and moving to production. An unprecedented large area of several 100m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  13. A high-precision X-ray tomograph for quality control of the ATLAS Muon Monitored Drift Tube Chambers

    CERN Document Server

    Schuh, S; Banhidi, Z; Fabjan, Christian Wolfgang; Lampl, W; Marchesotti, M; Rangod, Stephane; Sbrissa, E; Smirnov, Y; Voss, Rüdiger; Woudstra, M; Zhuravlov, V

    2004-01-01

    A dedicated X-ray tomograph has been developed at CERN to control the required wire placement accuracy of better than 20mum of the 1200 Monitored Drift Tube Chambers which make up most of the precision chamber part of the ATLAS Muon Spectrometer. The tomograph allows the chamber wire positions to be measured with a 2mum statistical and 2mum systematic uncertainty over the full chamber cross-section of 2.2 multiplied by 0.6m**2. Consistent chamber production quality over the 4-year construction phase is ensured with a similar to 15% sampling rate. Measurements of about 70 of the 650 MDT chambers so far produced have been essential in assessing the validity and consistency of the various construction procedures.

  14. Development of special ionization chambers for a quality control program in mammography; Desenvolvimento de camaras de ionizacao especiais para controle de qualidade em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jonas Oliveira da

    2013-07-01

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  15. The construction and the quality assurance-quality control of the 112 MDT-Barrel Inner Small precision chambers of the ATLAS Muon Spectrometer

    International Nuclear Information System (INIS)

    The construction of the 112 BIS monitored drift-tube chambers (MDT) for the ATLAS muon spectrometer is described, with emphasis on the quality assurance-quality control procedures. The required mechanical precision of 20μm on the location of the individual wires has been achieved and maintained during the five years of construction at University of Thessaloniki. A sample of 12% of the chambers, randomly selected over the entire production period, has been scanned at the X-ray tomograph facility at CERN. The agreement between the quality assurance-quality control measurements during the assembly and the X-ray tomograph results is also presented

  16. A design study for a 'spiral staircase' ionization chamber for the quality control of electron beams

    International Nuclear Information System (INIS)

    In order to verify that the energies of electron beams used for external beam therapy remain constant, IPEM 81 recommends a constancy check based on the ratio of ionization chamber measurements at two depths along the central axis. Such measurements for a range of electron energies can be a time consuming process. The purpose of this study was to design a device that would use several ion chambers simultaneously to measure electron depth dose curves, and hence the electron energy. A design was developed for a device consisting of ten independent ionization chambers, shaped and arranged in a solid phantom like the steps of a spiral staircase, the axis of the staircase being coincident with the axis of the electron beam. Measurements were carried out to test the design of individual chambers and to optimize the radius of the spiral and both the depth intervals and the lateral spacing between adjacent chambers. For ranges of electron energy from 6-12 MeV and 12-20 MeV the radii of the spirals needed were found to be 36.5 mm and 30.9 mm, the angular separations between edges of the chambers were 52 deg. and 30 deg. and chamber depths were found to be 10, 15, 20, 25, 30, 35, 40, 45, 50, 55 mm and 20, 40, 45, 50, 55, 60, 65, 70, 75, 80 mm, respectively. (note)

  17. Cyclically controlled welding purge chamber

    Science.gov (United States)

    Gallagher, Robert L. (Inventor)

    1996-01-01

    An arrangement for butt-welding cylindrical sections of large, thin-wall tanks includes a rotatable mandrel with side-by-side sets of radial position adjusters. Each set of adjusters bears on one of the tank sections adjacent the seam, to prevent the sections from sagging out-of-round. The mandrel rotates relative to the welder, so that a continuous seam is formed. A purge chamber is fixed in position behind the seam at the weld head, and is flushed with inert gas. The purge chamber includes a two-sided structure which is contiguous with the cylindrical sections and a circumferential vane to form an open-ended tube-like structure, through which the radial position adjusters pass as the mandrel and cylindrical workpiece sections rotate. The tube-like structure is formed into a chamber by a plurality of movable gates which are controlled to maintain a seal while allowing adjusters to progress through the purge chamber.

  18. Absolute absorbed dose measurements with an array of ionization chambers as part of a routine procedure of quality control for the VMAT technique

    International Nuclear Information System (INIS)

    Arcotheraphy techniques volumetric modulated (VMAT) treatments involve continuous variation of the gantry rotation speed, positions of the sheets and dose rate. Since all treatments are administered by continuous arcs, these techniques require quality control procedures to ensure quick and easy constancy of the calibration factor (total absorbed dose) for any gantry angle. We report here a simple method of quality control for the measurement of the calibration factor using an array of ionization chambers. The measurements were performed on a unit of 6 MV Elekta Synergy with VMAT, belonging to the Radiation Oncology service of the Defense Central Hospital Gomez Ulla.

  19. Limited streamer chamber testing and quality evaluation in ASTRA

    International Nuclear Information System (INIS)

    Limited streamer chambers are extensively used for high-energy and nuclear physics experiments in accelerator and underground laboratories. The tracking system of LVD, an underground experiment to study muons and nutrino astronomy, will use roughly 15000 limited streamer chambers and 100000 external pickup strips with digital readout electronics. In the article the different aspects of chamber operation that serve to establish a testing procedure and to define acceptance criteria for selecting reliable and long-life devices, are discussed. The procedures and the results obtained from a long-term test to evaluate streamer chamber quality, based upon a sample of 2900 items, are described. The selection tests and the long-term observations have been performed in the ASTRA laboratory, established at the Laboratori Nazionali di Frascati to carry out quality control procedures for streamer chambers on a large scale and in a controlled environment

  20. Preliminary study for elaborating a quality control program for scintillation chambers; Estudo preliminar para a elaboracao de um programa de controle de qualidade para camaras de cintilacao

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Rodrigo Alves; Ojeda, Renato Garcia [Santa Catarina Univ., Florianopolis, SC (Brazil). Escola de Engenharia Eletrica. Grupo de Pesquisas em Engenharia Biomedica

    1998-07-01

    This article presents a preliminary study, relative to quality control procedures to plane and tomographic (SECT) medical images, done by means of scintillation cameras. The study intends to consider and justify the most important aspects that should compose a quality control program program in the area. For so much, were considered international protocols that have been adopted all over the world, especially in developing countries, and the own Brazilian medical nuclear norm. (author)

  1. Quality Control Procedures Applied to the CMS Muon Chambers Built at CIEMAT; Procedimientos de Control de Calildad de las Camaras de Muones del Experimento CMS Construidas en el CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Fouz, M. C.; Puerta Pelayo, J.

    2004-07-01

    In this document the quality control procedures applied to the CMS muon drift chmabers built at CIEMAT are described. It includes a description of the high voltage and front electronics associated to the chambers. Every procedure is described with detail and a list of the more common problems and possible solutions is given. This document can be considered as a chambert test handbook for beginners. (Author) 3 refs.

  2. Quality control of the prostate tumor dosimetry performed by real-time dosimetry system COMPASS transmission chamber

    International Nuclear Information System (INIS)

    The most commonly used methodology for the verification of IMRT planning using radiochromic films and specific measures in a homogeneous phantom which move the control points of treatment. This system has the drawback of using a homogeneous model ignores the effect of the heterogeneities and the peculiarities of the patient's anatomy. This coupled with the fact obtain an evaluation in real time of each treatment fraction led us to use the new system COMPASS (I was Dosimetry) for the validation of planning.

  3. The estimation of lung dose from mid-perineum ionization chamber measurements in total body irradiations: A quality control check on dose delivery

    International Nuclear Information System (INIS)

    A series of patients (eleven males and eight females) receiving total body irradiation prior to bone marrow transplantation was monitored during treatment by recording the dose from an ionization chamber placed between the thighs in the mid-perineal region. The treatment was delivered by opposed lateral 6 MV photon beams. The patient was encompassed by the radiation field with the maximum collimator opening at a distance of 3.49 m from the X-ray focus to the patient mid-line. An analysis was made of the measured dose and the calculated percentage average lung dose for each patient in the series to seek a correlation between measured doses and patients' anatomical data so that estimates of delivered lung doses could be made. Whilst a global factor can be applied to measured dose to predict lung dose, it is concluded that perineal dose measurements distal to the region where dose is prescribed (mean lung dose) are sub-optimal for checks on target dose delivery. Entrance and exit dose measurements at the level of dose prescription (in the thorax) are preferable for more accurate predictions and quality control checks. 6 refs., 1 tab., 2 figs

  4. The estimation of lung dose from mid-perineum ionization chamber measurements in total body irradiations: A quality control check on dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Cross, P. [Saint Vincent`s Hospital, Darlinghurst, NSW (Australia)

    1995-11-01

    A series of patients (eleven males and eight females) receiving total body irradiation prior to bone marrow transplantation was monitored during treatment by recording the dose from an ionization chamber placed between the thighs in the mid-perineal region. The treatment was delivered by opposed lateral 6 MV photon beams. The patient was encompassed by the radiation field with the maximum collimator opening at a distance of 3.49 m from the X-ray focus to the patient mid-line. An analysis was made of the measured dose and the calculated percentage average lung dose for each patient in the series to seek a correlation between measured doses and patients` anatomical data so that estimates of delivered lung doses could be made. Whilst a global factor can be applied to measured dose to predict lung dose, it is concluded that perineal dose measurements distal to the region where dose is prescribed (mean lung dose) are sub-optimal for checks on target dose delivery. Entrance and exit dose measurements at the level of dose prescription (in the thorax) are preferable for more accurate predictions and quality control checks. 6 refs., 1 tab., 2 figs.

  5. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18F and 153Sm were obtained, making possible to determine activities of these radionuclides. (author)

  6. An innovative "ChemicalVia" process for the production of high density interconnect printed circuit boards The ATLAS muon chamber quality control with the X-ray tomograph at CERN

    CERN Document Server

    Da Silva, Vitor; Watts, David; Van der Bij, Erik; Banhidi, Z; Berbiers, Julien; Lampl, W; Marchesotti, M; Rangod, Stephane; Sbrissa, E; Schuh, S; Voss, Rüdiger; Zhuravlov, V

    2004-01-01

    The ChemicalVia process, patented by CERN, provides a new method of making microvias in high-density multilayer printed circuit boards of different types, such as sequential build-up (SBU), high density interconnected (HDI), or laminated multi-chip modules (MCM-L). The process uses chemical etching instead of laser, plasma or other etching techniques and can be implemented in a chain production line. This results in an overall reduced operation and maintenance cost and a much shorter hole production time as compared with other microvia processes. copy Emerald Group Publishing Limited. 4 Refs.4 An essential part of the Muon Spectrometer of the ATLAS experiment is based on the Monitored Drift Tube (MDT) technology. About 1200 muon drift chambers are being built at 13 institutes all over the world. The MDT chambers require an exceptional mechanical construction accuracy of better than 20 mu m. A dedicated X-ray tomograph has been developed at CERN since 1996 to control the mechanical quality of the chambers. The...

  7. Data Quality Monitoring for the CMS Resistive Plate Chamber Detector

    Science.gov (United States)

    Cimmino, A.; CMS Collaboration

    2011-06-01

    Resistive Plate Chambers (RPCs), with their excellent time resolution (˜ 2 ns), were chosen as dedicated muon trigger detectors for the CMS experiment. RPCs fulfill the job of muon identification, estimate the momentum and unambiguously assign bunch crossing. The critical tasks of monitoring detector performances, debugging hardware, and certifying recorded data are carried out by the RPC Data Quality Monitoring (DQM) system. We here describe the structure, functionalities, and performances of the DQM applications for the CMS RPC detector.

  8. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities

    International Nuclear Information System (INIS)

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  9. Chamber Quality Factors for the NACP-02 Chamber in 60Co Beams: Comparison of EGSnrc and PENELOPE Monte Carlo Simulations

    International Nuclear Information System (INIS)

    A new comparison of the values published for the chamber quality factor fc,Q0 of a NACP-02 plane-parallel chamber in 60Co, calculated with the Monte Carlo (MC) systems EGSnrc and PENELOPE, shows a difference of approximately 0.5%. The authors analyse possible reasons for this difference and recalculate the chamber quality factor with EGSnrc. Variations in the simulation transport parameters of EGSnrc result in changes smaller than the difference. An investigation of the most important uncertainties of cross-sectional data, considering variations in the mean excitation energy of stopping powers and in the total photon cross-sections, shows uncertainties comparable to the differences between the two codes for the chamber quality factor. Variations of the front wall thickness of the NACP-02 chamber, in the range of discrepancies with manufacturer data reported in the literature, result in significant changes in the calculated values. However, the difference in fc,Q0 cannot be explained in terms of these modifications. Hence, although both codes have been demonstrated to yield artefact free ion chamber simulations, a convergence of results for this particular problem cannot be achieved. An uncertainty estimate which takes into account the 0.5% difference for the MC calculated chamber quality factors seems to be a reasonable assumption. (author)

  10. Wire chamber radiation detector with discharge control

    International Nuclear Information System (INIS)

    A wire chamber radiation detector has spaced apart parallel electrodes and grids defining an ignition region in which charged particles or other ionizing radiations initiate brief localized avalanche discharges and defining an adjacent memory region in which sustained glow discharges are initiated by the primary discharges. Conductors of the grids at each side of the memory section extend in orthogonal directions enabling readout of the X-Y coordinates of locations at which charged particles were detected by sequentially transmitting pulses to the conductors of one grid while detecting transmissions of the pulses to the orthogonal conductors of the other grid through glow discharges. One of the grids bounding the memory region is defined by an array of conductive elements each of which is connected to the associated readout conductor through a separate resistance. The wire chamber avoids ambiguities and imprecisions in the readout of coordinates when large numbers of simultaneous or near simultaneous charged particles have been detected. Down time between detection periods and the generation of radio frequency noise are also reduced

  11. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  12. Factors controlling the structures of magma chambers in basaltic volcanoes

    Science.gov (United States)

    Wilson, L.; Head, James W.

    1991-01-01

    The depths, vertical extents, and lateral extents of magma chambers and their formation are discussed. The depth to the center of a magma chamber is most probably determined by the density structure of the lithosphere; this process is explained. It is commonly assumed that magma chambers grow until the stress on the roof, floor, and side-wall boundaries exceed the strength of the wall rocks. Attempts to grow further lead to dike propagation events which reduce the stresses below the critical values of rock failure. The tensile or compressive failure of the walls is discussed with respect to magma migration. The later growth of magma chambers is accomplished by lateral dike injection into the country rocks. The factors controlling the patterns of growth and cooling of such dikes are briefly mentioned.

  13. Design of basic chamber of the Main Control Valve

    Directory of Open Access Journals (Sweden)

    S.W. Lee

    2008-06-01

    Full Text Available Purpose: The development of a control valve for closed circuit requires comprehensive technologies in the overall precision machinery industry, from the development of casting materials for the housing to various types of parts. The development of a new type of control valve would have great advantage with a long lifecycle. Therefore, it is necessary to secure the MCV (Main Control Valve development technology that applies various sensors. This paper aims at providing a fundamental base for the establishment of design systems including the flow chamber design database of the MCV for wheel loaders, strength and rigidity design system, and the system for energy efficiency improvement. Particularly, this study set up the basic design database for the flow chamber design to establish the flow chamber design database, and secured the stability of the flow chamber from the basic design stage. In addition, major design variables were determined by utilizing a statistical technique in order to design such flow chamber.Design/methodology/approach: This study uses the I-DEAS to analyze the MCV structure characteristics. In addition, it uses the factorial design and sensitivity analysis to select important factors for the MCV design.Findings: This study establishes the unit flow chamber database for the MCV housing unit and the governing equation for the flow chamber.Research limitations/implications: Since the MCV damage often occurs due to the problem with the material itself and in the manufacturing process, it is difficult to tell clearly whether it occurred as the MCV reached the failure pressure.Practical implications: The basic data needed to design the MCV can be provided, and the required time for the design and the reliability of the design can be reduced and improved respectively.Originality/value: The verification of the design factors obtained from the flow analysis and structural analysis as well as the DOE was made by fabricating a sample

  14. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  15. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  16. study on trace contaminants control assembly for sealed environment chamber

    Science.gov (United States)

    Pang, L. P.; Wang, J.; Liu, L. K.; Liu, H.

    The biological and Physicochemical P C life support technologies are all important parts to establish a human Closed Ecological Life Support System CELSS for long-duration mission The latter has the advantages of lower power consumption lower mass and higher efficiency therefore researchers often incorporate the use of biological systems with P C life support technologies to continuously recycle air water and part of the solid waste stream generated such as the Russian BLSS and the NASA-sponsored Lunar-Mars Life Support Test Project LMLSTP In short these tests were very successful in integrating biological and P C life support technologies for long-duration life support Therefore we should use a combination of integrated biological with P C life support technologies in a human CELSS Human construction materials plants animals and soils release much trace toxic gases in a CELSS and they will inhibit plant growth and badly affect human health when their concentrations rise over their threshold levels The effect of biological trace contaminant control technologies is slower especially for a human sealed chamber because human produce much more methane and other contaminants A regenerative Trace Contaminant Control Subsystem TCCS with P C technology is a more important part in this case to control quickly the airborne contaminants levels and assure human in good condition in a sealed chamber This paper describes a trace contaminant control test facility incorporated a 8 m3 sealed environment chamber a regenerative TCCS with P C

  17. Design of viewing windows for controlled-atmosphere chambers

    International Nuclear Information System (INIS)

    A guide to the design of safe viewing windows is presented. Design criteria, the properties of materials, the problems of structural design in unreliable materials such as glass, the mathematics of reliability and redundance, and problems associated with testing windows are discussed, and formulas are presented for the design of windows. Criteria adopted at ORNL for controlled-atmosphere chambers are presented, a program for surveying and upgrading the safety of existing facilities is described, and the results of this program are reported

  18. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  19. Quality control of three BrightView XCT gamma chambers in the first six months of operation; Control de calidad de tres gammacamaras BrightView XCT en los seis primeros meses de funcionamiento

    Energy Technology Data Exchange (ETDEWEB)

    Palomo Linares, R.; Marti Vidal, J. F.; Olivas Arroyo, C.

    2013-09-01

    This study sought to compare the behaviour of the three gamma chambers of the Nuclear Medicine Department of La Fe Hospital. For this, we perform a series of periodic measurements of the two most important subsystems in the operation of the equipment, the nuclear medicine imaging acquisition system, SPECT, and X-ray imaging system for tomography, XCT. The study had an acquisition time of the first six months of operation of the gamma cameras. It is noted that the three gamma chambers have particular behaviours, being the time required between calibrations for both subsystems entirely individual. In addition, there was a large variability among the periods of the different calibrations, depending on the type of calibration performed by the Philips Technical Service. (Author)

  20. The LabVIEW based slow control system for the BESIII drift chamber cosmic rays test

    International Nuclear Information System (INIS)

    In the Beijing Spectrometer (BESIII) drift chamber cosmic rays test, there are hundreds of parameters need to be adjusted or set, which involves several hardware devices. The main task of slow control system is to monitor and control these parameters accurately, such as the gas rate, high voltage, voltage and current of electronics, fan speed, temperature and humidity and so on. The goal of the system is to test the construction quality of the detector and acquire a set of best parameters for it. Based on no ready-made software, we must develop a Slow Control System with the features of high flexibility and ease of use in limited time. This paper gives an introduction to the design and implementation of the LabVIEW based slow control system for the BESIII drift chamber cosmic rays test. (authors)

  1. Shielded chamber control stations: an answer to radiological protection requirements

    International Nuclear Information System (INIS)

    This study, carried out at the radiometallurgy laboratory of the Fontenay-aux-Roses Nuclear Research Centre, is based on an ergonomic approach. It shows that the shielded chamber control station, designed for human protection against ionizing radiations, demands an effort of adaptation on the part of the operator. This station does in fact meet radiological protection obligations but would benefit from certain improvements aimed at reducing the secondary fatigue of manipulators already under the strain of adapting to the machine. Fields in which improvements and/or changes are desirable have been investigated with special reference to telemanipulators. New and better designed instruments will soon appear on the telemanipulator market

  2. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  3. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  4. Calibration of Pencil Type Ionization Chambers at Various Irradiation Lengths and Beam Qualities

    International Nuclear Information System (INIS)

    Pencil type ionization chambers are being used in several diagnostic radiology applications, for the measurement of the air kerma length product, PKL. This work investigates several aspects of the pencil chamber calibration. The air kerma behind the apertures that are used for the partial irradiation of the pencil chambers depends on the irradiation set-up and equals to the air kerma free in air only under 'good geometry' irradiation conditions. Appropriate correction factors, kw, may be needed for this. The residual signal of four pencil chamber models was measured using various apertures widths. The residual signal should be subtracted from chamber signal in order to improve accuracy. Twenty-three commercial pencil type chambers were calibrated at RQT radiation qualities. The variation of performance between chambers of the same model and between different models is discussed, while the energy dependence of their response is presented. Finally, a comparison of the two calibration methods (total and partial irradiation of chamber) showed that both methods deduce similar calibration coefficients. The uncertainties of the measurements are assessed and discussed. (author)

  5. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  6. Multi axis motor control system for BARC-TIFR LINAC scattering chamber

    International Nuclear Information System (INIS)

    A general purpose scattering chamber of 150 cm diameter and 50 cm height is recently installed at BARC-TIFR LINAC facility. Scattering chamber is used in several experiments using particle accelerators. A remote controlled system is developed to perform various operation in scattering chamber. Four servo motors with PLC interface have been used to meet the precise positioning of target and detectors in scattering chamber. User interface software has been developed in Java which interacts with the system over Ethernet

  7. Quality control review: implementing a scientifically based quality control system.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2016-01-01

    This review focuses on statistical quality control in the context of a quality management system. It describes the use of a 'Sigma-metric' for validating the performance of a new examination procedure, developing a total quality control strategy, selecting a statistical quality control procedure and monitoring ongoing quality on the sigma scale. Acceptable method performance is a prerequisite to the design and implementation of statistical quality control procedures. Statistical quality control can only monitor performance, and when properly designed, alert analysts to the presence of additional errors that occur because of unstable performance. A new statistical quality control planning tool, called 'Westgard Sigma Rules,' provides a simple and quick way for selecting control rules and the number of control measurements needed to detect medically important errors. The concept of a quality control plan is described, along with alternative adaptations of a total quality control plan and a risk-based individualized quality control plan. Finally, the ongoing monitoring of analytic performance and test quality are discussed, including determination of measurement uncertainty from statistical quality control data collected under intermediate precision conditions and bias determined from proficiency testing/external quality assessment surveys. A new graphical tool, called the Sigma Quality Assessment Chart, is recommended for demonstrating the quality of current examination procedures on the sigma scale. PMID:26150675

  8. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types

    Energy Technology Data Exchange (ETDEWEB)

    Muir, B. R., E-mail: Bryan.Muir@nrc-cnrc.gc.ca [Measurement Science and Standards, National Research Council Canada, 1200 Montreal Road, Ottawa, Ontario K1A 0R6 (Canada); Rogers, D. W. O., E-mail: drogers@physics.carleton.ca [Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, 1125 ColonelBy Drive, Ottawa, Ontario K1S 5B6 (Canada)

    2014-11-01

    Purpose: To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers’ effective point of measurement (EPOM) and beam quality conversion factors. Methods: The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R{sub 50} converted from I{sub 50} (calculated using ion chamber simulations in phantom) to R{sub 50} calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. Results: For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, k{sub Q}, as a function of R{sub 50}. The optimal shift of cylindrical chambers is found to be less than the 0.5 r{sub cav} recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 r{sub cav}. Values of k{sub ecal} are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R{sub 50} = 7.5 cm (k{sub Q}{sup ′}) are provided. These

  9. AN EXPERIMENTAL INVESTIGATION OF HUMIDITY CONTROL IN A TEST CHAMBER

    Directory of Open Access Journals (Sweden)

    L. B.Diwakar

    2015-08-01

    Full Text Available Relative humidity is also generally used as an Rindicator ofthe air quality in the building and it is assumed that properhumidity control will also provide acceptable gasconcentrations. Therefore, humidity control has long beenrecognized as one of the most important approaches to improvethe environment of livestock buildings. However, due to thecorrosive environment of livestock facilities, the accuracy ofhumidity sensors is affected to varying degrees and they caneven fail after a relatively short barn exposure (Erdebil andLeonard 1989; Hao and Leonard 1994; Lemay et al. 1998.Consequently, incorporation of RH data into the environmentalcontrol strategy for livestock buildings is limited by theavailability of RH sensors which are economical and reliable,require low maintenance, and provide an easy interface withautomatic controllers. Hence, humidity control has not beenwidely implemented and the majority of current animalproduction facilities use temperature-only control (TC strategy.

  10. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  11. Optimizing control of quality management

    OpenAIRE

    Fliginskih Tatyana Nikolayevna; Fedoretc Ksenia Sergeevna

    2012-01-01

    This paper describes the technology that permits controlling of business processes in industry. An example of the use of control charts as one of the most effective methods of statistical quality control of products. The author provides a definition that best reveals the understanding of quality and quality control.

  12. Optimizing control of quality management

    Directory of Open Access Journals (Sweden)

    Fliginskih Tatyana Nikolayevna

    2012-05-01

    Full Text Available This paper describes the technology that permits controlling of business processes in industry. An example of the use of control charts as one of the most effective methods of statistical quality control of products. The author provides a definition that best reveals the understanding of quality and quality control.

  13. Development of fission chamber for nuclear reactors controlling

    International Nuclear Information System (INIS)

    Fission Chambers are gas-filled type detectors that operate in the ionization chamber regime, which is without electron multiplication. As the fill-gas is not directly ionized by neutrons, fission chambers are lined with fissile material that through interaction with neutrons fission products are produced, are highly ionizing particles. Pulse type operation of these detectors are used for neutron flux measurements during start up and shut-down reactor conditions in which pulses of high amplitude produced by fission products can be easily discriminated from those produced by alpha radiation from uranium and also from the external gamma field. With current or current fluctuation mode operation (Campbell) the use of these detectors can be extended for the whole range of reactor operation. In this work, it is presented the development and construction of a fission chamber at IPEN-CNEN/SP. Furthermore, the material and techniques used and also the operational characteristics obtained with the first prototype are given. (author)

  14. Quality control in audit firm

    OpenAIRE

    Dostálová, Milena

    2008-01-01

    Thesis deals with the quality control of audit firms in accordance with international regulations. Defining the requirements for quality based on the Code of Ethics and the International quality standard ISQC1. Part of this work is the practical demonstration of ISQC1 in the smaller audit firm. For comparison, there is a description of quality control in the U.S.

  15. Photon quality correction factors for ionization chambers in an epithermal neutron beam

    International Nuclear Information System (INIS)

    The radiation field of a neutron beam optimized for boron neutron capture therapy constitutes of a mixture of a photon and a neutron component. The photon and neutron absorbed dose to tissue have different biological effectiveness, suggesting that they should be determined separately. The thermal neutron absorbed dose component can be determined in phantom materials using activation probes. The photon and the fast neutron component can be determined using ionization chambers. The response of ionization chambers in different photon beams has recently been reported for conventional radiation therapy. Thus far, the beam quality correction factors kQ-factors) for photons for ionization chambers in epithermal neutron beams have been assumed equal to unity or estimated through measurements in accelerator produced photon beams. In the present study the kQγ- factors have been determined for two commercially available detectors in an epithermal neutron beam optimized for BNCT using the Monte Carlo method

  16. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    International Nuclear Information System (INIS)

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber's continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis

  17. SIMBAD quality-control

    Science.gov (United States)

    Lesteven, Soizick

    1992-01-01

    The astronomical database SIMBAD developed at the Centre de donnees astronomiques de Strasbourg presently contains 760,000 objects (stellar and non-stellar). It has the unique characteristic of being structured specifically for astronomical objects. All types of heterogeneous data (bibliographic references, measurements, and sets of identification) are connected with each object. The attributes that define quality of the database include the following. Reliability: cross-identification should not rely upon just exact values object coordinates. It also means that information attached to one simple object should be consistent. The existing data must be controlled in order to start with a reliable base and to cross-identify new data assuring the quality as data grows. Exhaustivity: delays between publication of new informations and their inclusion in the database should be as short as possible. The integrity of the database has to be maintained as data accumulates. Taking the amount of data into consideration and the rate of new data production, it is necessary to use automatic methods. One of the possibilities is to use multivariate data analysis. The factor-space is a n-dimensional relevancy space which is described by the n-axes representing a set of n subject matter headings; the words and phrases can be used to scale the axes and the documents are then a vector average of the terms within them. The application reported herein is based on the NASA-STI bibliographical database. The selected data concern astronomy, astrophysics, and space radiation (102,963 references from 1975 to 1991 included 8070 keywords). The F-space is built from this bibliographical data. By comparing the F-space position obtained from the NASA-STI keywords with the F-space position obtained from the SIMBAD references, the authors will be able to show whether it is possible to retrieve information with a restricted set of words only. If the comparison is valid, this will be a way to enter

  18. Quality control of radioisotopic products

    International Nuclear Information System (INIS)

    Radiopharmaceutical quality control is a very comprehensive and responsible activity since it concerns products being used for the health care of patients. Quality control is practised by an analytical specialist in close cooperation with pharmacists who are responsible for routine quality assurance. There is also a good understanding with the production group to ensure high-quality products. Quality control also relies on the research and development group to investigate problems. Finally there is feedback from the user since he is also responsible for quality control in a limited way. The scope of quality control is comprehensive, e.g. physical inspection and chemical control of all inactive starting material including supervision of the various stages of production. The quality control of radioactive material includes nuclidic analysis, verification of radiochemical purity as well as regular stability checks. Biological controls comprise sterility tests both on final products and production environment; testing for toxicity, pyrogens and LD50 values. To test product efficacy it is imperative to rely on biodistribution. Rabbits are used for quality control screening in a qualitative static mode and the dissection of mice organs is carried out for time-consuming quantitative analyses. Since radiopharmaceuticals are being used in a dynamic mode by nuclear medicine, their quality control tests on animals should, for proper evaluation, be carried out by means of comparative studies with imported products and by using a high-resolution camera with computer facilities. The Group for Quality Control and Assurance is responsible for an extensive documentation system which ensures both good manufacturing practice and effective analytical tests. Through quality control the specialist is constantly striving for improvement to ensure a good product for the benefit of the patient

  19. Characterization of the exradin A18 chamber ionization according to the IEC70631 standards. This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances

    International Nuclear Information System (INIS)

    This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances. (Author)

  20. Analysis of Heat Stress and the Indoor Climate Control Requirements for Movable Refuge Chambers

    Science.gov (United States)

    Hao, Xiaoli; Guo, Chenxin; Lin, Yaolin; Wang, Haiqiao; Liu, Heqing

    2016-01-01

    Movable refuge chambers are a new kind of rescue device for underground mining, which is believed to have a potential positive impact on reducing the rate of fatalities. It is likely to be hot and humid inside a movable refuge chamber due to the metabolism of trapped miners, heat generated by equipment and heat transferred from outside. To investigate the heat stress experienced by miners trapped in a movable refuge chamber, the predicted heat strain (PHS) model was used to simulate the heat transfer process between the person and the thermal environment. The variations of heat stress with the temperature and humidity inside the refuge chamber were analyzed. The effects of air temperature outside the refuge chamber and the overall heat transfer coefficient of the refuge chamber shell on the heat stress inside the refuge chamber was also investigated. The relationship between the limit of exposure duration and the air temperature and humidity was numerically analyzed to determine the upper limits of temperature and humidity inside a refuge chamber. Air temperature of 32 °C and relative humidity of 70% are recommended as the design standard for internal thermal environment control of movable refuge chambers. PMID:27213422

  1. Analysis of Heat Stress and the Indoor Climate Control Requirements for Movable Refuge Chambers.

    Science.gov (United States)

    Hao, Xiaoli; Guo, Chenxin; Lin, Yaolin; Wang, Haiqiao; Liu, Heqing

    2016-01-01

    Movable refuge chambers are a new kind of rescue device for underground mining, which is believed to have a potential positive impact on reducing the rate of fatalities. It is likely to be hot and humid inside a movable refuge chamber due to the metabolism of trapped miners, heat generated by equipment and heat transferred from outside. To investigate the heat stress experienced by miners trapped in a movable refuge chamber, the predicted heat strain (PHS) model was used to simulate the heat transfer process between the person and the thermal environment. The variations of heat stress with the temperature and humidity inside the refuge chamber were analyzed. The effects of air temperature outside the refuge chamber and the overall heat transfer coefficient of the refuge chamber shell on the heat stress inside the refuge chamber was also investigated. The relationship between the limit of exposure duration and the air temperature and humidity was numerically analyzed to determine the upper limits of temperature and humidity inside a refuge chamber. Air temperature of 32 °C and relative humidity of 70% are recommended as the design standard for internal thermal environment control of movable refuge chambers. PMID:27213422

  2. Statistical model of quality of radon measurements using electret ion chamber detectors

    International Nuclear Information System (INIS)

    This paper presents a statistical model for estimating probability, which states that a quality of radon measurements using the electret ion chamber system RM-1 will be accurate. The quality of the electret measurement was modelled as a ratio between the reference radon concentration and values measured under real conditions with varied levels of indoor radon concentration and microclimate indoor conditions. It was stated that the accuracy tolerance of measured values is 20 % of the given reference value. To estimate the uncertainty of the statistical model, the exact confidence limits for the estimated probabilities are computed. The statistical model was confirmed by an independent set of measurements. Moreover, the effect of absolute humidity on the quality estimation of electret detectors are also statistically analysed and discussed. The results of the statistical model confirm that the electret system is robust and suitable for estimation of radon concentration. (authors)

  3. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves to...

  4. Process control of product quality.

    Science.gov (United States)

    Venkatesan, G

    2003-10-01

    This paper describes a method to control output product quality (product variability) by applying engineering or automatic process control (APC) and statistical process control (SPC) techniques. APC techniques have been used to control process variables such as feed rate, temperature, pressure, viscosity, and to product quality variables as well. SPC techniques have also been applied to control product quality. APC and SPC techniques overlap at the interface of the two process control methodologies. It is possible to produce material of desired quality by having an acceptable level of variation in the measured output characteristics. APC aims to maintain certain key process variables as near their set points for as much of the time as possible. There are situations in process control where some form of feedback control is necessary and yet where stability cannot be easily attained in the feedback control loop. Disturbance (noise) afflicts a process, which together with issues of dynamics and dead time (time delay) compounds the process control problem. The process control practitioner faces a challenge while tackling issues of process delay (dead time) and dynamics (inertia). Process control of product variability (control error standard deviation) is possible by developing and simulating a feedback control algorithm for dead-time processes. It is quite common to encounter problems connected with feedback (closed-loop) control stability, controller limitations, and dead-time compensation to obtain minimum variance (mean square error) control at the output. Details of a method to control the quality of a product at output by applying statistical process monitoring and feedback control adjustment are presented in this paper. The focus of this paper is on the issues of process delay ("dead time") and dynamics ("inertia") at the interface between SPC and APC to control output product quality. PMID:14582886

  5. One-dimensional flame instability and control of burning in fire-chamber

    Directory of Open Access Journals (Sweden)

    Victor E. Volkov

    2015-03-01

    Full Text Available The flame stability with regard to one-dimensional exponential perturbations both for the combustion in the fire-chamber and the flame propagating in closed tubes or chambers is investigated. It is proved that both stability and instability are possible for the combustion process. At the same time the one-dimensional flame instability is guaranteed near the front wall of the fire-chamber where the fuel supply is realized. Therefore the control of combustion in the fire-chamber leads to support of the flame at the maximum possible distance from the front wall of the fire-chamber to prevent the vibratory combustion or to diminish intensity of pulsations if these pulsations are inevitable.

  6. Short communication: Assessment of activity patterns of growing rabbits in a flux-controlled chamber

    Directory of Open Access Journals (Sweden)

    Irene Olivas

    2013-06-01

    Full Text Available Flux-controlled and metabolic chambers are often used for nutritional and environmental studies. However, the potential alterations of animal behaviour and welfare are so far not fully understood. In consequence, this study had 2 main objectives: to assess potential alterations of animal activity pattern and time budget inside a flux chamber, and to assess the importance of the “rearing up” behaviour. To this end, 10 growing rabbits of different ages (from 1 to 5 wk of the growing period were housed inside a flux chamber. Their activity was continuously recorded and assessed, determining the frequency and duration of 8 different behaviours: lying, sleeping, sitting, eating, drinking, walking, rearing up and others. Nocturnal rabbit behaviour and time budget were not altered inside the chamber if compared to previously described rabbit activity under conventional cages. In addition, rabbits in this experiment presented a tendency to perform “rearing up” when housed inside the flux chamber.

  7. Quality control tests for the CMS Barrel RPCs

    International Nuclear Information System (INIS)

    An RPC based system will be employed for the CMS muon first level trigger. Severe quality controls and certification have been established all along the entire production chain. Procedures are briefly described and results for the acceptance percentage are given for the second part of the single gaps and double gaps production. Summary results are also reported for the full sets of tested chambers

  8. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  9. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  10. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA)

  11. Determination of quality factor in mixed radiation fields using a recombination chamber

    International Nuclear Information System (INIS)

    A recombination chamber was used for determination of the recombination index of radiation quality (Q4). The possibility of calculation of the quality factor defined by ICRP Report 60 from the measured Q4 values is discussed. The calculations were performed for the experimental results, obtained in radiation fields of fast neutrons (from 0.9 MeV up to 14 MeV), high energy (350 MeV) neutrons, high energy (200 MeV) protons and for alpha particles. It was found that the calculation procedure can be used for most existing mixed radiation fields with accuracy of about 25%, if the photon component of the absorbed dose is independently determined. (author)

  12. Quality control and quality assurance procedures at the THOR BNCT facility

    International Nuclear Information System (INIS)

    Various quality control (QC) and quality assurance (QA) procedures of the boron neutron capture therapy (BNCT) beam at the Tsing Hua Open-pool Reactor (THOR) are established to ensure beam availability and quality. The QC/QA methods mainly employ foil activation and paired ionization chambers, respectively, for beam intensity check and dose assessment. Beam intensity is monitored on-line by using three dead-time corrected fission chambers. In addition to the periodic QC/QA activities regarding beam quality and the monitoring system, the quick QC/QA performed in an all-in-one phantom will be executed less than 70 min before the clinical treatment to guarantee beam quality. The QC/QA procedures have been gradually established and the actual performance satisfied the preset criteria defined for the BNCT facility at THOR.

  13. CA Water Quality Control Board

    Data.gov (United States)

    U.S. Environmental Protection Agency — Regional Water Quality Control Boards(9) in California. These district boundaries coincide with the boundaries of some of the hydrologic study areas delineated by...

  14. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (131I, 14C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  15. Construction of control and instrumentation devices of high voltage power supply of double chamber plasma nitrogen

    International Nuclear Information System (INIS)

    A control and instrumentation devices of high voltage power supply of double chamber plasma nitrogen have been made. This device consists of the software and hardware component. Hardware component consists of SCR phase angle controller LPC-50HDA type, T100MD1616+ PLC, high voltage transformer and voltage rectifier system. Software component used a LADDER program and TBasic serves to control of the high voltage output. The components in these devices have been tested in the double chamber plasma nitrogen. Its performance meet with the design criteria that can supply of plasma nitrogen operation voltage in the range 290 Vdc to 851 Vdc with glow discharge current 0.4 A to 1.4 A. In general it can be said that the control and instrumentation devices of high voltage power supply is ready for use at the double chamber plasma nitrogen device. (author)

  16. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  17. 10 CFR 26.137 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.137 Section 26....137 Quality assurance and quality control. (a) Quality assurance program. Each licensee testing facility shall have a quality assurance program that encompasses all aspects of the testing...

  18. 10 CFR 26.167 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.167 Section 26... Department of Health and Human Services § 26.167 Quality assurance and quality control. (a) Quality assurance program. Each HHS-certified laboratory shall have a quality assurance program that encompasses all...

  19. Essential elements of quality control.

    Science.gov (United States)

    Boylan, J C

    1983-11-01

    The components of quality control in the pharmaceutical industry are discussed as they apply to hospital pharmacy admixture services. The pharmaceutical industry complies with the FDA's Current Good Manufacturing Practices, which require manufacturers to have written procedures for ensuring sterility and nonpyrogenicity of injectable products. Because FDA specifies only what outcome measures must be assessed (rather than specific means of assessment), pharmaceutical companies have developed a multiplicity of quality-control systems. However, each system consists of a master formula (quantitative listing of all ingredients), master manufacturing instructions (the recipe for each product), master packaging instructions, and batch records. Documents used by quality control personnel include the specifications (identification, tests, and limits for products), test methods, and sampling procedures. Hospitals should have similar quality-control programs. These programs should systematically prevent or identify and correct deficiencies, measure overall quality, and provide information for managers. Hospital pharmacists whose departments do not have comprehensive programs should consult colleagues who have developed such procedures. Techniques used in industry should be applied when possible. To protect the integrity of manufacturers' drug products during compounding in hospitals, every hospital admixture service must have its own quality-control system. PMID:6650523

  20. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  1. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves to...... through the origo. Calibration control is an essential link in the traceability of results. Only one or two samples of pure solid or aqueous standards with accurately known content need to be analyzed. Verification is carried out by analyzing certified reference materials from BCR, NIST, or others; their...

  2. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  3. Quality assurance of proton beams using a multilayer ionization chamber system

    International Nuclear Information System (INIS)

    Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF

  4. Quality control without a budget

    International Nuclear Information System (INIS)

    This paper has been prepared to provide assistance to those radiographers wishing to undertake equipment quality control in the Radiology Department where funding for this function is minimal or non-existent. Successful quality assurance means the ability to maximize the use of the radiation dose to patients and simultaneously reduce staff dose; plus maximize cost savings through improved patient throughput, reduced wastage of resources such as film, chemistry and staff time. 10 refs., 6 figs

  5. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  6. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    The association between radiation measurements and quality control is established for radiation sterilization of medical products and food irradiation. Good quality control implies accurate radiation dosimetry and a discussion of the factors which can affect the accuracy of in-plant dosimetry is presented. It is argued that if systematic errors are to be avoided in in-plant dosimetry the plant operators will have to spend more time and effort in developing the skills associated with the accurate use of radiation dosemeter systems. The aims and merits of an international intercomparison programme recently set up by the IAEA are discussed. The benefits of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good quality control. (author)

  7. Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation

    International Nuclear Information System (INIS)

    The quality correction factor for used beam and qualities is strongly required for clinical dosimetry by TRS-398 protocol of IAEA. In this study the quality correction factors for a commercial plane-parallel ionization chamber in high energy electron beams were calculated by Monte Carlo code (DOSRZnrc/EGSnrc). In comparison of quality correction factor, the difference between this study and TRS-398 were within 1% in 5-20 MeV. In case of 4MeV the difference was 1.9%. As an independent method of determination of quality correction factor this study can be applied to evaluate values in the protocol or calculate the factor for a new chamber.

  8. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is... quality control frequencies by using statistical process control to monitor equipment performance on...

  9. Patient specific IMRT quality assurance with film, ionization chamber and detector arrays: Our institutional experience

    International Nuclear Information System (INIS)

    Purpose: This study was conducted to review patient specific IMRT QA delivered at our institution using Varian LINACs and TomoTherapy Hi-Art system and categorized according to the anatomical site, type of treatment machine, and treatment planning systems (TPS). Material and methods: Three thousand and three hundred seven patient data were evaluated for a time ranging from 2006 to 2011; these data were gauged using several methods used in the QA process. Ion chambers and film were used in 1738 patient plan QA in the earlier years followed by ion chamber arrays in 1569 patient plan QA in the latter years. Patients were grouped according to several parameters including TPS, site of treatment, and type of treatment machine in comparing the measured versus computed dose differences. From 2006 through early 2009, 736 TomoTherapy plans, 651 Pinnacle3 plans, and 351 Corvus plans were evaluated using ion chambers and films. The pass criterion at the institution at the time of these measurements was 3% dose difference and 3 mm distance to agreement. For the years ranging from 2009 to 2011, 1569 patient IMRT QAs were performed and evaluated on the institution's pass criteria of 90% γ value on Varian linacs with Millennium 80, 120 and High-Definition 120 multileaf collimators. Results: Average point dose difference between measured and calculated plans for Pinnacle3, Hi-ART TomoTherapy, and Corvus TPS were 0.1205%, −0.0042%, and −0.0178%. Among the QA plans measured using a 2D array, average gamma values for brain, head and neck, thorax, abdomen, and pelvis were 97.2%, 95.7%, 96.2%, 97.0%, and 96.2%, respectively. Average gamma values based on 80, 120, HD 120 and TomoTherapy MLC configurations were 96.5%, 96.2%, 96.3%, and 97%, respectively. A 2-tailed paired Student's T-test did not reveal the presence of statistically significant differences based on either TPS, anatomical sites, number of beams or arcs, number of control points, or the MLC configuration (p

  10. Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Muir, B. R.; McEwen, M. R.; Rogers, D. W. O. [Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada); Institute for National Measurement Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6 (Canada); Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada)

    2012-03-15

    Purpose: To investigate the behavior of plane-parallel ion chambers in high-energy photon beams through measurements and Monte Carlo simulations. Methods: Ten plane-parallel ion chamber types were obtained from the major ion chamber manufacturers. Absorbed dose-to-water calibration coefficients are measured for these chambers and k{sub Q} factors are determined. In the process, the behaviors of the chambers are characterized through measurements of leakage currents, chamber settling in cobalt-60, polarity and ion recombination behavior, and long-term stability. Monte Carlo calculations of the absorbed dose to the air in the ion chamber and absorbed dose to water are obtained to calculate k{sub Q} factors. Systematic uncertainties in Monte Carlo calculated k{sub Q} factors are investigated by varying material properties and chamber dimensions. Results: Chamber behavior was variable in MV photon beams, especially with regard to chamber leakage and ion recombination. The plane-parallel chambers did not perform as well as cylindrical chambers. Significant differences up to 1.5% were observed in calibration coefficients after a period of eight months although k{sub Q} factors were consistent on average within 0.17%. Chamber-to-chamber variations in k{sub Q} factors for chambers of the same type were at the 0.2% level. Systematic uncertainties in Monte Carlo calculated k{sub Q} factors ranged between 0.34% and 0.50% depending on the chamber type. Average percent differences between measured and calculated k{sub Q} factors were - 0.02%, 0.18%, and - 0.16% for 6, 10, and 25 MV beams, respectively. Conclusions: Excellent agreement is observed on average at the 0.2% level between measured and Monte Carlo calculated k{sub Q} factors. Measurements indicate that the behavior of these chambers is not adequate for their use for reference dosimetry of high-energy photon beams without a more extensive QA program than currently used for cylindrical reference-class ion chambers.

  11. Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams

    International Nuclear Information System (INIS)

    Purpose: To investigate the behavior of plane-parallel ion chambers in high-energy photon beams through measurements and Monte Carlo simulations. Methods: Ten plane-parallel ion chamber types were obtained from the major ion chamber manufacturers. Absorbed dose-to-water calibration coefficients are measured for these chambers and kQ factors are determined. In the process, the behaviors of the chambers are characterized through measurements of leakage currents, chamber settling in cobalt-60, polarity and ion recombination behavior, and long-term stability. Monte Carlo calculations of the absorbed dose to the air in the ion chamber and absorbed dose to water are obtained to calculate kQ factors. Systematic uncertainties in Monte Carlo calculated kQ factors are investigated by varying material properties and chamber dimensions. Results: Chamber behavior was variable in MV photon beams, especially with regard to chamber leakage and ion recombination. The plane-parallel chambers did not perform as well as cylindrical chambers. Significant differences up to 1.5% were observed in calibration coefficients after a period of eight months although kQ factors were consistent on average within 0.17%. Chamber-to-chamber variations in kQ factors for chambers of the same type were at the 0.2% level. Systematic uncertainties in Monte Carlo calculated kQ factors ranged between 0.34% and 0.50% depending on the chamber type. Average percent differences between measured and calculated kQ factors were - 0.02%, 0.18%, and - 0.16% for 6, 10, and 25 MV beams, respectively. Conclusions: Excellent agreement is observed on average at the 0.2% level between measured and Monte Carlo calculated kQ factors. Measurements indicate that the behavior of these chambers is not adequate for their use for reference dosimetry of high-energy photon beams without a more extensive QA program than currently used for cylindrical reference-class ion chambers.

  12. Simulation study of the photon quality correction factors of ionization chambers for FiR 1 epithermal neutron beam

    International Nuclear Information System (INIS)

    At FiR 1 BNCT facility in Finland, neutron-insensitive Mg(Ar) ionization chambers are used for photon dose measurements in an epithermal neutron beam. Previously, photon sensitivity factors for the chamber for the measurements in a water phantom in FiR 1 beam have been determined experimentally from measurements in 60Co gamma and in a 6 MV clinical accelerator photon beams. However, the response of the ionization chamber in a water phantom depends on energy spectrum and angle of the photons and the secondary electrons created inside the phantom and may differ depending on type of the irradiation source (accelerator vs. an epithermal neutron beam). Also, the experimental sensitivity factor does not take into account the possible perturbations in the photon production in phantom caused by the ionization chamber materials. Therefore, it is necessary to determine the photon quality correction factors (kQγ) for the Mg(Ar) chamber at the FiR 1 beam through computer simulations. In this study, the kQγ factors have been determined for Mg(Ar) chamber from Monte Carlo calculations of absorbed photon dose at two depths in a water phantom using MCNP code. The kqγ factors obtained with this method are compared to the sensitivity factors determined with measurements in an accelerator photon beam and to the kQγ factors published previously. (author)

  13. Radiographic quality: Control and evaluation

    International Nuclear Information System (INIS)

    The control and evaluation of radiographic quality vary considerably from institution to institution, and this has resulted in increased government legislation in most jurisdictions, which attempts to provide some measure of uniformity in standards of equipment installation, maintenance, and use. Where legislation is not yet in place, it is pending, so that all facilities using x-radiation are, or soon will be, legally bound to operate within accepted guidelines. These guidelines are established to provide the radiologist with radiographs of optimum diagnostic quality while keeping the radiation dose to the patient and radiology personnel as low as possible. There are many excellent publications that provide detailed step-by-step instructions on each facet of radiographic quality control; these procedures will, therefore, not be covered in detail here. The following information may, however, be of interest as it relates primarily to pediatric radiography and will prove useful to those initiating quality control and evaluation programs; it is important that priorities be established - the necessary steps are listed below

  14. Quality control of EUVE databases

    Science.gov (United States)

    John, L. M.; Drake, J.

    1992-01-01

    The publicly accessible databases for the Extreme Ultraviolet Explorer include: the EUVE Archive mailserver; the CEA ftp site; the EUVE Guest Observer Mailserver; and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public EUVE databases are working properly, and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this poster, we describe the Quality Assurance (QA) procedures we have developed from the approach of QA as a service organization, thus reflecting the overall EUVE philosophy of Quality Assurance integrated into normal operating procedures, rather than imposed as an external, post facto, control mechanism.

  15. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  16. Control of quality in mammography

    International Nuclear Information System (INIS)

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  17. Application of Programmable Logic Controller (PLC) in Control System for Inner and Outer Welding Processes of Irradiation Chamber

    International Nuclear Information System (INIS)

    Inner and outer welding processes of irradiation chamber require reliable human resources so that the welding results will meet the standardized requirements for irradiation with nuclear reactor. The control system of the inner and outer welding processes of the irradiation chamber was made due to limited human resources who are able to weld the irradiation chamber perfectly. The irradiation chamber’s welding is expected to be done automatically by using the system control. The system is created by using Programmable Logic Controller (PLC) which function is to automatically organize the welding processes through the codes attached there in. The system comprises of a control unit which has been tested in a simulation, and then attached in a welding machine unit, and subsequently tested for welding the irradiation chamber. The result of the welding is also tested for its leak using bubble test. As all procedures are well followed in the welding processes, the control system is found to work properly. The welding results which are not optimum are mainly due to imperfect irradiation tubes, such as the lack of symmetry in the tube’s geometry, unclean surface, as well as the condition of the unprecise mechanical part of the tubes. (author)

  18. CRANE WHEELS PRODUCTION QUALITY CONTROL

    OpenAIRE

    OTTO GRIGOROV; SERHY GUBSKIY; ANTON OKUN

    2014-01-01

    Quality control of crane wheels is an important part for support of crane mechanisms permanent operation. Normal functioning of logistics systems requires preventing of crane downtimes and delays. The research results of the impact of the crane wheels (710 mm diameter, 65 steel) surface hardness on coercivity indicators are presented in this paper. Obtained research results of dependence between the coercivity indicators and the crane wheels rolling surface hardness for their use in practice ...

  19. Quality Control of Meteorological Observations

    Science.gov (United States)

    Collins, William; Dee, Dick; Rukhovets, Leonid

    1999-01-01

    For the first time, a problem of the meteorological observation quality control (QC) was formulated by L.S. Gandin at the Main Geophysical Observatory in the 70's. Later in 1988 L.S. Gandin began adapting his ideas in complex quality control (CQC) to the operational environment at the National Centers for Environmental Prediction. The CQC was first applied by L.S.Gandin and his colleagues to detection and correction of errors in rawinsonde heights and temperatures using a complex of hydrostatic residuals.Later, a full complex of residuals, vertical and horizontal optimal interpolations and baseline checks were added for the checking and correction of a wide range of meteorological variables. some other of Gandin's ideas were applied and substantially developed at other meteorological centers. A new statistical QC was recently implemented in the Goddard Data Assimilation System. The central component of any quality control is a buddy check which is a test of individual suspect observations against available nearby non-suspect observations. A novel feature of this test is that the error variances which are used for QC decision are re-estimated on-line. As a result, the allowed tolerances for suspect observations can depend on local atmospheric conditions. The system is then better able to accept extreme values observed in deep cyclones, jet streams and so on. The basic statements of this adaptive buddy check are described. Some results of the on-line QC including moisture QC are presented.

  20. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  1. The segmented non-uniform dielectric module design for uniformity control of plasma profile in a capacitively coupled plasma chamber

    Directory of Open Access Journals (Sweden)

    Huanxiong Xia

    2014-12-01

    Full Text Available Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance.

  2. The segmented non-uniform dielectric module design for uniformity control of plasma profile in a capacitively coupled plasma chamber

    International Nuclear Information System (INIS)

    Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance

  3. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this... establish, with the approval of the Secretary, such minimum quality and inspection requirements...

  4. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture... MICHIGAN, NEW YORK, PENNSYLVANIA, OREGON, UTAH, WASHINGTON, AND WISCONSIN Order Regulating Handling Quality Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  5. Wide Field-of-View Fluorescence Imaging with Optical-Quality Curved Microfluidic Chamber for Absolute Cell Counting

    Directory of Open Access Journals (Sweden)

    Mohiuddin Khan Shourav

    2016-07-01

    Full Text Available Field curvature and other aberrations are encountered inevitably when designing a compact fluorescence imaging system with a simple lens. Although multiple lens elements can be used to correct most such aberrations, doing so increases system cost and complexity. Herein, we propose a wide field-of-view (FOV fluorescence imaging method with an unconventional optical-quality curved sample chamber that corrects the field curvature caused by a simple lens. Our optics simulations and proof-of-concept experiments demonstrate that a curved substrate with lens-dependent curvature can reduce greatly the distortion in an image taken with a conventional planar detector. Following the validation study, we designed a curved sample chamber that can contain a known amount of sample volume and fabricated it at reasonable cost using plastic injection molding. At a magnification factor of approximately 0.6, the curved chamber provides a clear view of approximately 119 mm2, which is approximately two times larger than the aberration-free area of a planar chamber. Remarkably, a fluorescence image of microbeads in the curved chamber exhibits almost uniform intensity over the entire field even with a simple lens imaging system, whereas the distorted boundary region has much lower brightness than the central area in the planar chamber. The absolute count of white blood cells stained with a fluorescence dye was in good agreement with that obtained by a commercially available conventional microscopy system. Hence, a wide FOV imaging system with the proposed curved sample chamber would enable us to acquire an undistorted image of a large sample volume without requiring a time-consuming scanning process in point-of-care diagnostic applications.

  6. Progress in analytical methods to predict and control azimuthal combustion instability modes in annular chambers

    OpenAIRE

    Bauerheim, Michaël; Nicoud, Franck; Poinsot, Thierry

    2016-01-01

    Longitudinal low-frequency thermoacoustic unstable modes in combustion chambers have been intensively studied experimentally, numerically, and theoretically, leading to significant progress in both understanding and controlling these acoustic modes. However, modern annular gas turbines may also exhibit azimuthal modes, which are much less studied and feature specific mode structures and dynamic behaviors, leading to more complex situations. Moreover, dealing with 10–20 burners mounted in the ...

  7. Control of out-of-furnace ecologically safe metallothermic smelting in a hermetic chamber

    Science.gov (United States)

    Ovsov, N. S.; Eliseev, Yu. E.; Bogdanov, C. V.

    2014-12-01

    To create a low-vacuum atmosphere and excess pressure in a hermetic melting chamber is shown to be useful for block smelting. The results of combined control of the smelting process by changing the pressure of the gases released from a crucible in melting a metal in the reactor-autoclave regime are presented. These results are used to provide ecologically safe conditions for the production of ingots 1.5-2 t in weight.

  8. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  9. DOUBLE LOOP ACTIVE VIBRATION CONTROL OF PNEUMATIC ISOLATOR WITH TWO SEPARATE CHAMBERS

    Institute of Scientific and Technical Information of China (English)

    YANG Qingjun; LI Jun; WANG Zuwen

    2006-01-01

    A newly designed pneumatic spring with two separate chambers is promoted and double-loop active control is introduced to overcome the following drawbacks of passive pneumatic level with different force load. The design of two separate chambers is for the purpose of tuning support frequency and force independently and each chamber is controlled by a different valve. The inner one of double-loop structure is pressure control, and in order to obtain good performance,nonlinearities compensation and motion flow rate compensation (MFRC) are added besides the basic cascade compensation, and the influence of tube length is studied. The outer loop has two functions:one is to eliminate the resonance caused by isolation support and to broaden the isolation frequency band by payload velocity feedback and base velocity feed forward, and the other is to rune support force and support stiffness simultaneously and independently, which means the support force will have no effect on support stiffness. Theoretical analysis and experiment results show that the three drawbacks are overcome simultaneously.

  10. Quality control of pesticide products

    International Nuclear Information System (INIS)

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  11. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  12. High-quality diamond films grown at high deposition rates using high-power-density MWPCVD method with conventional quartz-type chamber

    Science.gov (United States)

    Nakai, Takahiro; Arima, Kazuya; Maida, Osamu; Ito, Toshimichi

    2007-12-01

    Undoped and boron-doped homoepitaxial diamond films with high quality have been successfully grown on high-pressure/high-temperature-synthesized type-Ib single-crystalline diamond (1 0 0) substrates. In the growth process, a conventional microwave-plasma (MWP) chemical-vapor-deposition (CVD) system with an easily-exchangeable 36-mm-inner-diameter quartz-tube growth chamber was employed under a condition of high MW power densities while a rather high methane concentration (4%) and high substrate temperatures (>1000 °C) were used. The growth conditions applied to the undoped and B-doped diamond thin films were separately optimized by controlling the MW plasma density and substrate temperatures. The homoepitaxial films thus grown yielded strong exciton-related luminescence even at room temperature, meaning that their crystalline quality was good and roughly comparable with that of homoepitaxial films deposited using a high-power MWPCVD system with a stainless steel chamber having a rather large diameter. This indicates that by using such a conventional deposition system with inexpensive and easily-exchangeable exclusive-use quartz-tube chambers, various growth experiments can be performed under different process conditions without any severe interference among the different experiments.

  13. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  14. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  15. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  16. Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

    International Nuclear Information System (INIS)

    The CEBAF Large Acceptance Spectrometer (CLAS) is a superconducting toroidal magnet with a large volume of drift chambers for charged particle tracking. The performance of these chambers depends on accurate monitoring and control of the mixture, flow rate, pressure, temperature, and contaminant levels of the gas. To meet these requirements, a control system is being developed with EPICS. The interface hardware consists of VME ADCs and three RS-232 low-level hardware controllers. The RS-232 instruments include MKS 647A mass flow controllers to control and monitor the gas mixture and flow, MKS 146B pressure gauge controllers to measure pressures, and a Panametrics hygrometer to monitor temperatures and the concentrations of oxygen, water vapor, and ethane. Many of the parameters are available as analog signals which will be monitored with XYCOM VME analog input cards and configured for alarms and data logging. The RS-232 interfaces will be used for remote control of the hardware and verification of the analog readings. Information will be passed quickly and efficiently to and from the user through a graphical user interface. A discussion of the requirements and design of the system is presented

  17. ASCAT Scatterometer Wind Quality Control

    Science.gov (United States)

    Portabella, M.; Stoffelen, A.; Verhoef, A.; Verspeek, J.

    2010-12-01

    The so-called Advanced scatterometer (ASCAT), onboard MetOp-A satellite was successfully launched on October 19 2006. ASCAT derived sea surface wind field observations are well within the mission accuracy requirements. An important part of the Numerical Weather Prediction Satellite Application Facility (NWP-SAF) ASCAT Data Wind Processor (AWDP) is the wind data quality control (QC). This paper shows the implementation of a new QC procedure, based on the wind inversion residual, which significantly improves the effectiveness of the scatterometer wind data QC.

  18. State-of-the-art exposure chamber for highly controlled and reproducible THz biological effects studies

    Science.gov (United States)

    Cerna, Cesario Z.; Elam, David P.; Echchgadda, Ibtissam; Sloan, Mark A.; Wilmink, Gerald J.

    2014-03-01

    Terahertz (THz) imaging and sensing technologies are increasingly being used at international airports for security screening purposes and at major medical centers for cancer and burn diagnosis. The emergence of new THz applications has directly resulted in an increased interest regarding the biological effects associated with this frequency range. Knowledge of THz biological effects is also desired for the safe use of THz systems, identification of health hazards, and development of empirically-based safety standards. In this study, we developed a state-of-the-art exposure chamber that allowed for highly controlled and reproducible studies of THz biological effects. This innovative system incorporated an industry grade cell incubator system that permitted a highly controlled exposure environment, where temperatures could be maintained at 37 °C +/- 0.1 °C, carbon dioxide (CO2) levels at 5% +/- 0.1%, and relative humidity (RH) levels at 95% +/- 1%. To maximize the THz power transmitted to the cell culture region inside the humid incubator, a secondary custom micro-chamber was fabricated and incorporated into the system. This micro-chamber shields the THz beam from the incubator environment and could be nitrogen-purged to eliminate water absorption effects. Additionally, a microscope that allowed for real-time visualization of the live cells before, during, and after THz exposure was integrated into the exposure system.

  19. New assembly of ionization chambers for the RBMK reactor control systems

    International Nuclear Information System (INIS)

    A new assembly consisting of ionization chambers (IC) and cables is developed for the RBMK reactor control systems (RCS). The assembly together with the channel of RCS ensures reliable power control in the range from 10-10 to 1.5 nominal power and measuring the neutron flux density in the reactor core height. The design of the assembly with IC is presented. Tests showed that the new IC assembly provides high sensitivity of measurements and RCS channel noise immunity in all range of reactor power variation

  20. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities; Estudo do desempenho da CI de padrao primario para implantacao das qualidades em radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Quaresma, Daniel da Silva; Peixoto, Jose Guilherme Pereira, E-mail: ricardo@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ/LNMRI), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes

    2013-07-01

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  1. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product...

  2. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which...

  3. Evaluation of tecniques for controlling UF6 release clouds in the GAT environmental chamber

    International Nuclear Information System (INIS)

    Studies designed to characterize the reaction between UF6 and atmospheric moisture, evaluate environmental variables of UF6 cloud formation and ultimate cloud fate, and UF6 release cloud control procedure have been conducted in the 1200 cu. ft. GAT environmental chamber. In earlier chamber experiments, 30 separate UF6 release tests indicated that variations of atmospheric conditions and sample sizes had no significant effect on UO2F2 particle size distribution, release cloud formation, or cloud settling rates. During the past year, numerous procedures have been evaluated for accelerating UF6 cloud knockdown in a series of 37 environmental chamber releases. Knockdown procedures included: coarse water spray; air jet; steam spray (electrostatically charged and uncharged); carbon dioxide; Freon-12; fine water mist (uncharged); boric acid mist (charged and uncharged); and an ionized dry air stream. UF6 hydrolysis cloud settling rates monitored by a laser/powermeter densitometer, indicated the relative effectiveness of various cloud knockdown techniques. Electrostatically charged boric acid/water mist, and electrostatically ionized dry air were both found to be very effective, knocking down the UO2F2 release cloud particles in two to five minutes. Work to adapt these knockdown techniques for use under field conditions is continuing, taking into account recovery of the released uranium as well as nuclear criticality constraints

  4. Quality assurance and quality control in monitoring programs

    Science.gov (United States)

    Shampine, W.J.

    1993-01-01

    There are three general characteristics of the data to be collected in a monitoring program that should be met in order to maximize the use and value of the data: the data quality should be known the data type and quality should be consistent and comparable, and the data should be available and accessible. Potential problems with each of these characteristics are addressed effectively by quality assurance and quality control. One of the most important aspects of quality assurance in a monitoring program is the development of a quality assurance plan, which should identify clearly the quality of the data needed and describe in detail the planned actions to provide confidence that the program will meet its stated objectives. Quality control data, which allow for the quality and suitability of the environmental data to be evaluated and ascertained, should be collected and utilized as an integral part of the QA effort associated with a monitoring program.

  5. Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  6. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  7. Development of a sample chamber with humidity control for an atmospheric positron probe microanalyzer

    International Nuclear Information System (INIS)

    In order to perform positron lifetime measurements on thin films under atmospheric conditions, a slow positron microbeam was extracted into air using silicon nitride thin films (30 nm and 200 nm) as a vacuum window. Even the thinner window (30 nm) was found to reliably withstand a differential pressure of 1 atm under various stress tests. By placing the sample in an enclosed chamber through which gas with a fixed, controllable relative humidity (RH) was continuously passed, the RH dependence of the ortho-positronium lifetime for bulk fused silica was examined.

  8. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  9. Effect of methane on the quality of tracks at the laser detection of electrons in helium streamer chamber

    International Nuclear Information System (INIS)

    The effect of methane on the quality of tracks at laser detection of electrons in a helium streamer chamber is investigated. It turned out that for the direct shadow-method registration of electron tracks at a field intensity of 10 kV/cm one should add more than 1% of methane. The addition of methane reduces the memory time and increases the refractive index of the gas mixture which gives a higher jump of the refractive index on the and of the streamer and photoionization suppression. These three factors affect favourably the possibility of track localization. Investigations using spark discharges in helium demonstrate that it is possible, in principle, to perform direct shadow-method registering of phase inhomogeneities in pure helium either. The influence of laser pulse delay time relatively to the beginning of dischange in the streamer chamber is also demonstrated on the shadowgraphs. An attempt has been made to interprete the observed effects

  10. Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance

    International Nuclear Information System (INIS)

    Aim of this study is to investigate the feasibility of 2D ion chamber array as a substitute of the water phantom system in a periodic Linac QA. For the feasibility study, a commercial ion chamber matrix was used as a substitute of the water phantom in the measurement for a routine QA beam properties. The device used in this study was the I'm RT MatriXX (Wellhofer Dosimetrie, Germany). The MatriXX consists of a 1,020 vented ion chamber array, arranged in 24 x 24 cm2 matrix. Each ion chamber has a volume of 0.08 cm3, spacing of 0.762 cm. We investigated dosimetric parameters such as dose symmetry, energy (TRP20,10), and absolute dose for comparing with the water phantom data with a Farmer-type ionization chamber (FC65G, Wellhofer Dosimetrie, Germany). For the MatriXX measurements, we used the white polystyrene phantom (ρ: 1.08 g/cm3) and also considered the intrinsic layer ((ρ: 1.06 g/cm3, t: 0.36 cm) of MatriXX to be equivalent to water depth. In the preliminary study of geometrical QA using MatriXX, the rotation axis of collimator and half beam junction test were included and compared with film measurements. Regarding the dosimetrical QA, the MatriXX has shown good agreements within ±1 compared to the water phantom measurements. In the geometrical test, the data from MatriXX were comparable with those from the films. In conclusion, the MatriXX is a good substitute for water phantom system and film measurements. In addition, the results indicate that the MatriXX as a cost-effective novel QA tool to reduce time and personnel power.

  11. Statistical Control of Measurement Quality

    International Nuclear Information System (INIS)

    Effective nuclear materials management, and hence design and operation of associated material control systems, depend heavily on the quality of the quantitative data on which they are based. Information concerning the reliability of the measurement methods employed is essential to both the determination of data requirements and the evaluation of results obtained. Any method of analysis should be (1) relatively free from bias and (2) reproducible, or, in more usual terminology, precise. Many statistical techniques are available to evaluate and control the reproducibility of analytical results. Economical and effective experimental designs have been developed for the segregation of different sources of measurement error. Procedures have been developed or adapted tot use in maintaining and controlling the precision of routine measurements. All of these techniques require that at least some measurements must be duplicated, but duplication of all measurements can be justified only when the detection of every gross error, or mistake, is extremely important. Three types of measurement bias can be considered: (1) bias relative to a standard, (2) bias relative to prior experience, and (3) bias relative to a group. The first refers to the degree to which the measurements obtained deviate systematically from some ''standard'' which is unbiased either (1) by definition, or (2) because all known sources of bias have been removed. The second in concerned with the presence of systematic differences over a period of time. The third type of bias concerns the relationship between different physical entities or individuals at a given time. Recent developments in statistical methodology applicable to the evaluation of all three types of bias are discussed. Examples of the use of the statistical techniques discussed on Hanford data are presented. (author)

  12. System for studies of control strategies applied in the refrigerated chambers Sistema para estudos de estratégias de controle aplicadas em câmaras frias

    Directory of Open Access Journals (Sweden)

    Alexandre Tizzei

    2011-10-01

    Full Text Available The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.O processo de armazenamento refrigerado em câmaras contribui, em grande parte, para a qualidade e a longevidade dos produtos. Nos últimos anos, têm-se intensificado os estudos de estratégias de controle com a finalidade de diminuir a variação da temperatura dentro da câmara de armazenamento e de reduzir o consumo de energia elétrica. Neste trabalho, foi desenvolvido um sistema para aquisição de dados e controle do processo, em linguagem LabVIEW, para ser aplicado no sistema de refrigeração de uma câmara frigorífica de 30m³. A utilização da instrumentação e do aplicativo desenvolvido possibilitou a realização de experimentos científicos, com o objetivo de estudar o comportamento dinâmico do sistema de refrigeração, comparar o desempenho das estratégias de controle da máquina térmica, tanto em função da temperatura controlada, quanto ao consumo de energia elétrica. Neste sistema, foram testadas as estratégias de controle liga-desliga, PID e fuzzy. Em

  13. Progress in analytical methods to predict and control azimuthal combustion instability modes in annular chambers

    Science.gov (United States)

    Bauerheim, M.; Nicoud, F.; Poinsot, T.

    2016-02-01

    Longitudinal low-frequency thermoacoustic unstable modes in combustion chambers have been intensively studied experimentally, numerically, and theoretically, leading to significant progress in both understanding and controlling these acoustic modes. However, modern annular gas turbines may also exhibit azimuthal modes, which are much less studied and feature specific mode structures and dynamic behaviors, leading to more complex situations. Moreover, dealing with 10-20 burners mounted in the same chamber limits the use of high fidelity simulations or annular experiments to investigate these modes because of their complexity and costs. Consequently, for such circumferential acoustic modes, theoretical tools have been developed to uncover underlying phenomena controlling their stability, nature, and dynamics. This review presents recent progress in this field. First, Galerkin and network models are described with their pros and cons in both the temporal and frequency framework. Then, key features of such acoustic modes are unveiled, focusing on their specificities such as symmetry breaking, non-linear modal coupling, forcing by turbulence. Finally, recent works on uncertainty quantifications, guided by theoretical studies and applied to annular combustors, are presented. The objective is to provide a global view of theoretical research on azimuthal modes to highlight their complexities and potential.

  14. Quality control of the crude oil derivatives

    International Nuclear Information System (INIS)

    OKTA is crude oil refinery and its primary activity is production of oil derivates and their distribution in order to fulfill Macedonian market with products in accordance with national standards that are in coordination with European standards from January 2004. Quality is multidisciplinary category consisted of many function. One of the functions of quality assurance is quality control. All employees should be concerned for the control that means also a big responsibility for them. For this reason, a competent team from several departments work and rise all knowledge and experience in providing production of final products with properties that satisfy the customer needs and are established with quality certificate. OKTA assures the established final products quality with quality control of crude oil, intermediates and final products, grants quality certificate, guarantee the quality and control the gas stations in order to satisfy the customers. (Author)

  15. Advanced control system for the scattering chamber of K-130 cyclotron

    International Nuclear Information System (INIS)

    The old relay based position control system of the Scattering Chamber of K-130 Cyclotron was more than 30 years old, developed multiple problems over the years, and the components of the control system like relays, potentiometers, limit switches, radiation resistant cables were not functioning as per specifications. It has been replaced recently by a new PLC based embedded control system. This has been developed using Advantech ADAM-5510EKW 16 bit CPU together with required I/O modules. MULTIPROG Basic V.4.6 has been used as programming software and Ladder Diagram has been used to realize control scheme of the PLC. A resistive type touch screen based operator panel, WebOP-2104VN4AE has been mounted on the control rack for local control. iFIX SCADA, 75 tags Runtime Version 5.1 has been used to operate from remote PC connected to the PLC by 70m CAT6 cable. The PLC communicates with the touch panel and remote PC through 100 Mbps Ethernet switch. The Graphical User Interfaces of the local control panel and the remote panel have been developed as per the requirement from the users. All the old sensors, limit switches, relays and cables have been replaced by new items. This paper reports about the development and commissioning of basic hardware, software and operation of the control system for last six months. (author)

  16. Audit and internal quality control in immunohistochemistry

    OpenAIRE

    Maxwell, P; McCluggage, W

    2000-01-01

    Aims—Although positive and negative controls are performed and checked in surgical pathology cases undergoing immunohistochemistry, internal quality control procedures for immunohistochemistry are not well described. This study, comprising a retrospective audit, aims to describe a method of internal quality control for immunohistochemistry. A scoring system that allows comparison between cases is described.

  17. Growing magma chambers control the distribution of small-scale flood basalts.

    Science.gov (United States)

    Yu, Xun; Chen, Li-Hui; Zeng, Gang

    2015-01-01

    Small-scale continental flood basalts are a global phenomenon characterized by regular spatio-temporal distributions. However, no genetic mechanism has been proposed to explain the visible but overlooked distribution patterns of these continental basaltic volcanism. Here we present a case study from eastern China, combining major and trace element analyses with Ar-Ar and K-Ar dating to show that the spatio-temporal distribution of small-scale flood basalts is controlled by the growth of long-lived magma chambers. Evolved basalts (SiO2 > 47.5 wt.%) from Xinchang-Shengzhou, a small-scale Cenozoic flood basalt field in Zhejiang province, eastern China, show a northward younging trend over the period 9.4-3.0 Ma. With northward migration, the magmas evolved only slightly ((Na2O + K2O)/MgO = 0.40-0.66; TiO2/MgO = 0.23-0.35) during about 6 Myr (9.4-3.3 Ma). When the flood basalts reached the northern end of the province, the magmas evolved rapidly (3.3-3.0 Ma) through a broad range of compositions ((Na2O + K2O)/MgO = 0.60-1.28; TiO2/MgO = 0.30-0.57). The distribution and two-stage compositional evolution of the migrating flood basalts record continuous magma replenishment that buffered against magmatic evolution and induced magma chamber growth. Our results demonstrate that the magma replenishment-magma chamber growth model explains the spatio-temporal distribution of small-scale flood basalts. PMID:26581905

  18. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    International Nuclear Information System (INIS)

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The present thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold,HV) was investigated quantitatively. Also detailed studies on single cells, qualified as ''dead'' and ''noisy'' were done. For the DAQ tests a flexible hardware and software environment was needed. The organization and installation of the supplied electronics, as well as the software development was realized within the scope of this thesis. The DCS tests were focused on the local gas pressure read-out components, attached directly to the chamber: pressure sensor, manifolds and the pressure ADC (PADC). At first it was crucial to proof, that the calibration of the mentioned chamber components for the gas pressure measurement is valid. The sensor calibration data were checked and possible differences in their response to the same pressure were studied. The analysis of the results indicated that the sensor output depends also on the ambient temperature, a new experience which implied an additional pedestal measurement of the chamber gas pressure sensors at CMS. The second test sequence

  19. Designing Single Chamber Hwcvd System for High Deposition Rate Device Quality A-Si:h Thin Films and Solar Cells

    Directory of Open Access Journals (Sweden)

    N.A. Wadibhasme

    2011-01-01

    Full Text Available A new single chamber HWCVD with vertically mounted substrates and filaments has been designed for depositing device quality a-Si:H films with high deposition rate. Optimization studies on films deposited in this chamber under a variety of deposition conditions yielded uniform films at more than 7Å/sec deposition rate and with very low oxygen content. These films show a photoconductivity gain of more than 105. The working pressure has been kept quite low at 15 mtorr compared to earlier studies. i-layers of a p-i-n single junction solar cells were deposited on the TCO (Asahi-U type glass in this reactor. The initial p-layer and the final n-layer were deposited in another system with separate chambers for these doped layers thus exposing the p-layer as well as the i-layer to the atmosphere during the transfer. Using this optimized intrinsic layer, a-Si:H based p-i-n solar cell showed a conversion efficiency of 4.7 %.

  20. Influence of size of the ionization chamber in determination of the quality of an X-ray field of references

    International Nuclear Information System (INIS)

    The quality of an X-ray field of reference can be evaluated with the determination of the values of the first and second half-value layer - 1st and 2nd CSR, from measurements carried out with appropriate ionisation chambers. The acceptance criteria of ISO 4037-1 states that the values of 1st and 2nd CSR may not differ by more than -5% of the reference values. Procedures have been developed on X-ray equipment PANTAK, model HF160, adjusted to produce a field of 48 keV X-ray, to investigate the determination of the values of 1st and 2nd CSR with the use of different ionization chambers of varying volumes. The initial results indicate that the values of 1st and 2nd CSR are influenced by the size of the ionization chamber used, which suggests the determination of algorithm for the determination of a single value of 1st and 2nd CSR

  1. Characterization of the exradin A18 chamber ionization according to the IEC70631 standards. This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances; Caracterizacion de la camara de ionizacion exradin A18 segun el estandar IEC70631. Estudio para haces de fotones sin filtro aplanador

    Energy Technology Data Exchange (ETDEWEB)

    Onses Segarra, A.; Puxeu Vaque, J.; Sancho Kolster, I.; Lizuain Arroyo, M. C.; Picon Olmos, C.

    2013-07-01

    This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances. (Author)

  2. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance

    International Nuclear Information System (INIS)

    The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). The detector calibration factor was determined using 300 kVp X-ray beams so that we can use the same calibration factor for dosimetric verification of high-dose-rate (HDR) brachytherapy. The phantom used for this measurement consists of multiple catheters, the IBA MatriXX detector, and water-equivalent slab of RW3 to provide full scattering conditions. The treatment planning system (TPS) (Oncentra brachy version 3.3, Nucletron BV, Veenendaal, the Netherlands) dose distribution was calculated on the computed tomography (CT) scan of this phantom. The measured and TPS calculated distributions were compared in IBA Dosimetry OmniPro-I‘mRT software. The quality of agreement was quantified by the gamma (γ) index (with 3% delta dose and distance criterion of 2 mm) for 9 sets of plans. Using a dedicated phantom capable of receiving 5 brachytherapy intralumenal catheters a QA procedure was developed for end-to-end dosimetric evaluation for routine QA checks. The 2D ion chamber array dose dependence was found to be linear for 100–300 kVp and the detector response (kuser) showed strong energy dependence for 100–300 kVp energy range. For the Ir-192 brachytherapy HDR

  3. MAIN PROBLEMS OF CONTROLLING OF THE QUALITY

    Directory of Open Access Journals (Sweden)

    Orlov A. I.

    2015-09-01

    Full Text Available Controlling of statistical methods to ensure product quality is the special case of controlling organizational and economic methods of management. Today, controlling in the practice of management of Russian companies is understood as "the system of information-analytical and methodological support to achieve their goals." The controller is developing a decision-making rules, the head takes decisions on the basis of these rules. We proved the concept of "controlling of methods". Innovation in management is based, in particular, on the use of new adequate organizational-economic (as well as economicmathematical and statistical methods. Controlling in this area - is the development and application procedures of compliance management used and newly developed (implemented organizationaleconomic methods for the task. Thus, the methodology for controlling is of great practical value in any field in which the actions (operations must be carried out in accordance with certain rules (regulations, standards, guidelines, as in any such area in which we need to use development and application procedures of compliance management used and the newly established (implemented rules for solution of tasks assigned to the organization. In this article, we select a area of controlling as controlling quality, and we discuss its main issues. This is about controlling of organizational-economic methods to ensure product quality, especially about the statistical methods based on probability theory and mathematical statistics. We consider the analysis and synthesis of plans of statistical quality control, optimization options plans of statistical control, truncated plans. Are discussed the differences control plans provider and the consumer, the allocation of units formless (liquid, gas products, the selection of a random sample of the statistical quality control of products, lower estimate of the required sample size. It is established, that is not always necessary

  4. Quality Control in Small Groups

    Science.gov (United States)

    Lemmens, L. F.

    2008-11-01

    The smallness of some groups in a set up to control the quality of a service using questionnaires limits the size of the samples, this limitation has several consequences. Indeed the common approach used for relatively large groups, based on the central limit theorem and the law of large numbers, cannot be used anymore to construct estimators for the parameters of the model. Using an inverse probability will lift these restrictions. A questionnaire is a collection of items. In an item the respondent indicates on a Likert scale his or her agreement with a statement. Dimensions are a set of items dealing with one aspect of the service. In a questionnaire several dimensions are addressed but usually the items are presented in a random sequence. The model for an item is hierarchical with following components: a multivariate hypergeometric model takes the sampling in a finite population into account, the multinomial serves as a prior for the sampling and the Dirichlet-distribution serves as a prior for the multinomials. The composition of dimensions allows to use the posterior for one of the items as a prior for another item of that dimension and so on. After analysis of several questionnaires using this model, the reliability of the responses from some respondents turned out to be a key-problem, in the sense the responses can be classified into at least two classes and a decision rule had to be developed to neglect some of them. The influence of rejecting some answers, on the confidence for the most plausible statement can be estimated. This leads often to the result that there is only minimal evidence for the most probable statement.

  5. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  6. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  7. Dosimetry and quality control in radiodiagnosis

    International Nuclear Information System (INIS)

    This work deals with physics of radiodiagnosis. In a first part a study of the characteristics of different kinds of radiological equipments and a quality assurance of some of them (standard radiography, coronarography and computed tomography) have been performed. The second part deals with patient irradiation. After a bibliographic study of radiodiagnosis dosimetry, two kinds of dosimetric measures have been made: ''in vitro'' measures, using a phantom, that had allowed to calibrate the equipment and to improve the individual irradiation card, and ''in vivo'' measures. For the first types of measures ionization chambers, have been used for the second thermoluminescent dosimeters

  8. Quality control in radiochemical analysis

    International Nuclear Information System (INIS)

    Whenever analytical data are to be used as a basis for a scientific study or even for monitoring purposes it is necessary to have information on the quality of the analyses. It is much better if this quality can be expressed in numerical form rather than subjectively and it is also better if the data are part of a continuing programme. All laboratories are involved in this question of analytical quality but the degree to which they develop the required information is highly variable. The present paper attempts to describe an ideal system and to present some data relating to analysis of seawater

  9. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  10. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique

  11. Correction factors for photon beam quality for cylindrical ionization chambers: Monte Carlo calculations by using the PENELOPE code

    International Nuclear Information System (INIS)

    Were directly determined correction factors depending on the type camera beam quality, k, Q, and kQ, Qo, instead of the product (w, air p) Q, for three type cylindrical ionization chambers Pinpoint and divergent monoenergetic beams of photons in a wide range of energies (4-20 MV). The method of calculation used dispenses with the approaches taken in the classic procedure considered independent of braking power ratios and the factors disturbance of the camera. A detailed description of the geometry and materials chambers were supplied by the manufacturer and used as data input for the system 2006 of PENELOPE Monte Carlo calculation using a User code that includes correlated sampling, and forced interactions division of particles. We used a photon beam Co-60 as beam reference for calculating the correction factors for beam quality. No data exist for the cameras PTW 31014, 31015 and 31016 in the TRS-398 at they do not compare the results with data calculated or determined experimentally by other authors. (author)

  12. Summary of Previous Chamber or Controlled Anthrax Studies and Recommendations for Possible Additional Studies

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Morrow, Jayne B.

    2010-12-29

    This report and an associated Excel file(a) summarizes the investigations and results of previous chamber and controlled studies(b) to characterize the performance of methods for collecting, storing and/or transporting, extracting, and analyzing samples from surfaces contaminated by Bacillus anthracis (BA) or related simulants. This report and the Excel are the joint work of the Pacific Northwest National Laboratory (PNNL) and the National Institute of Standards and Technology (NIST) for the Department of Homeland Security, Science and Technology Directorate. The report was originally released as PNNL-SA-69338, Rev. 0 in November 2009 with limited distribution, but was subsequently cleared for release with unlimited distribution in this Rev. 1. Only minor changes were made to Rev. 0 to yield Rev. 1. A more substantial update (including summarizing data from other studies and more condensed summary tables of data) is underway

  13. 7 CFR 981.442 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.442 Section 981.442 Agriculture... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed...

  14. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6...

  15. Quality control within the windmill branch

    International Nuclear Information System (INIS)

    The aim of the project was to improve the quality of Danish-produced wind turbines by initiating quality control and working out general technical guidelines compatible with European standards so that these products can be authorized internationally. Guidelines for blade production, and purchase of gear boxes are presented in addition to an explanation of the concept of quality control. Administrational procedures in relation to authorization are also explained. (AB)

  16. Symbolic quality control for multimedia applications

    OpenAIRE

    Combaz J.; Fernandez J.-C.; Sifakis J.; Strus L.

    2008-01-01

    We present a fine grain quality control method for multimedia applications. The method takes as input an application software composed of actions. The execution times of actions are unknown increasing functions of quality level parameters. The method allows the construction of a Controller which computes adequate action schedules and corresponding quality levels, so as to meet QoS requirements for a given platform. These include requirements for safety (action deadlines are met) as well optim...

  17. Analysis of SCR control circuit testing for power supply double chamber plasma nitriding

    International Nuclear Information System (INIS)

    Analysis of scr control circuit testing for power supply double chamber plasma nitriding has been performed. Analysis of testing was carried out to find out and validate the performance of the SCR control circuit. The testing method is direct measurement consist of oscillator circuit and SCR performance test. The analysis of oscillator circuit with main component of OT UJT 2646 and OT 240 transformer on the SCR control circuit was functioning properly. This can be seen with the formation of the 4 V voltage Vcc as an indication pulse signal to activate the gate on the SCR and at 12 V Vcc voltage (max) pulse signal is almost full. This pulse signal will be used to activate the SCR gate so that the SCR output voltage can be controlled. For SCR that installed on the doubler circuit, they are functioning properly too. The indication is the voltage on the output side of the doubler circuit is almost twice as the input side. The addition of test time (operation time) and the addition of the load current is proportional to the temperature of SCR. (author)

  18. Mechanical and dosimetric quality control for computer controlled radiotherapy treatment equipment.

    Science.gov (United States)

    Thompson, A V; Lam, K L; Balter, J M; McShan, D L; Martel, M K; Weaver, T A; Fraass, B A; Ten Haken, R K

    1995-05-01

    Modern computer controlled radiotherapy treatment equipment offers the possibility of delivering complex, multiple field treatments with minimal operator intervention, thus making multiple field conformal therapy practical. Conventional quality control programs are inadequate for this new technology, so new quality control procedures are needed. A reasonably fast, sensitive, and complete daily quality control program has been developed in our clinic that includes nearly automated mechanical as well as dosimetric tests. Automated delivery of these quality control fields is performed by the control system of the MM50 racetrack microtron, directed by the CCRS sequence processor [D. L. McShan and B. A. Fraass, Proceedings of the XIth International Conference on the use of computers in Radiation Therapy, 20-24 March 1994, Manchester, U.K. (North Western Medical Physics Department, Manchester, U.K., 1994), pp. 210-211], which controls the treatment process. The mechanical tests involve multiple irradiations of a single film to check the accuracy and reproducibility of the computer controlled setup of gantry and collimator angles, table orientation, collimator jaws, and multileaf collimator shape. The dosimetric tests, which involve multiple irradiations of an array of ionization chambers in a commercial dose detector (Keithly model 90100 Tracker System) rigidly attached to the head of the treatment gantry, check the output and symmetry of the treatment unit as a function of gantry and collimator angle and other parameters. For each of the dosimetric tests, readings from the five ionization chambers are automatically read out, stored, and analyzed by the computer, along with the geometric parameters of the treatment unit for that beam.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7643792

  19. Quality-control analytical methods: continuous quality improvement.

    Science.gov (United States)

    Venti, Eden M

    2006-01-01

    It is vital that all compounding pharmacies have a continuous quality improvement program in place by way of standard operating procedures to assure that patients receive high-quality preparations. The program should take into consideration any federal and state regulatory requirements, as well as professional association expectations. Quality control measurements and regular review of those measurements are the foundations of a good quality plan. All pharmacy personnel should be aware of the importance of reporting potential internal quality concerns or problems and should be encouraged to do so without fear of repercussions. Ideally, an error-free compounding pracitice would be the goal. Since this is not practical, quality issues should not be viewed as problems, but as opportunities to improve compounding practices by correcting, before they become pervasive, the processes used in the preparation of prescriptions. PMID:23974418

  20. A simple analytical model to study and control azimuthal instabilities in annular combustion chambers

    OpenAIRE

    Parmentier, Jean-François; Salas, Pablo; Wolf, Pierre; Staffelbach, Gabriel; Nicoud, Franck; Poinsot, Thierry

    2012-01-01

    This study describes a simple analytical method to compute the azimuthal modes appearing in annular combustion chambers and help analyzing experimental, acoustic and large eddy simulation (LES) data obtained in these combustion chambers. It is based on a one-dimensional zero Mach number formulation where N burners are connected to a single annular chamber. A manipulation of the corresponding acoustic equations in this configuration leads to a simple dispersion relation which can be solved by ...

  1. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author)

  2. Nonmicrobial alternative to reagent quality control testing.

    OpenAIRE

    Reynolds, S M

    1982-01-01

    The traditional approach to quality control in microbiology involves the routine testing of both media and reagents with live microbial cultures. This is expensive, time consuming, and subject to the variables associated with the use of live organisms. A system of reagent quality control based on the pure chemical form of the metabolic end products important to the identification of the Enterobacteriaceae was evaluated. The metabolite reagent control system is simple, reliable, and extremely ...

  3. Sensometrics for Food Quality Control

    OpenAIRE

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the ...

  4. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  5. Effect of pretreatment methods and chamber pressure on morphology, quality and adhesion of HFCVD diamond coating on cemented carbide inserts

    Science.gov (United States)

    Sarangi, S. K.; Chattopadhyay, A.; Chattopadhyay, A. K.

    2008-04-01

    In the present investigation, diamond coating was deposited on cemented carbide substrate by hot filament chemical vapour deposition. The effect of substrate pretreatment methods and chamber pressure on morphology, quality, and adhesion of the diamond film were studied. The carbide inserts were pretreated with acid, Murakami's solution, and Murakami's solution followed by acid, respectively. The chamber pressure was set at 6.6, 13.2, 26.4, 39.6 and 66 mbar. Deposition carried out at pressure of 26.4 and 39.6 mbar on inserts pretreated with acid exhibited uniform crystal habit and provided coating-substrate adhesion adequate for machining application. Good coating morphology was obtained when deposition was done at 6.6 mbar on carbide inserts treated with Murakami's solution. Pretreatment with Murakami's solution followed by acid and deposition at 6.6 mbar also resulted in good morphology of diamond film. Indentation (Rockwell C scale) was done on diamond-coated inserts to assess coating-substrate adhesion under three loads of 294, 588 and 980 N. The diameter of the indentation crack at the coating-substrate interface was observed under SEM. The results suggested that diamond coating deposited at medium pressure of 26.4 mbar on carbide substrate treated with acid not only exhibited best morphology but also highest coating-substrate adhesion and improved machining performance.

  6. Quality assurance and quality control in the radon measurement industry

    International Nuclear Information System (INIS)

    Since the release of survey results by the consumer advocacy group BUYERS-UP, QA/QC has bee the buzz word among everyone involved with Radon/Radon Decay Product measurement. This paper presents a discussion in generality of the roles of Quality Assurance and Quality Control in the Radon Measurement Industry, the strengths and weaknesses of QA/QC in radon measurement and the significance of research in QA/QC for radon measurement

  7. The control system of the multi-strip ionization chamber for the HIMM

    International Nuclear Information System (INIS)

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer–consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector

  8. The control system of the multi-strip ionization chamber for the HIMM

    Energy Technology Data Exchange (ETDEWEB)

    Li, Min, E-mail: limin@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yuan, Y.J. [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Mao, R.S., E-mail: Maorsh@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Xu, Z.G.; Li, Peng; Zhao, T.C.; Zhao, Z.L. [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); Zhang, Nong [Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2015-03-11

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer–consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  9. The control system of the multi-strip ionization chamber for the HIMM

    Science.gov (United States)

    Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong

    2015-03-01

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  10. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-09-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  11. Contamination Control Assessment of the World's Largest Space Environment Simulation Chamber

    Science.gov (United States)

    Snyder, Aaron; Henry, Michael W.; Grisnik, Stanley P.; Sinclair, Stephen M.

    2012-01-01

    The Space Power Facility s thermal vacuum test chamber is the largest chamber in the world capable of providing an environment for space simulation. To improve performance and meet stringent requirements of a wide customer base, significant modifications were made to the vacuum chamber. These include major changes to the vacuum system and numerous enhancements to the chamber s unique polar crane, with a goal of providing high cleanliness levels. The significance of these changes and modifications are discussed in this paper. In addition, the composition and arrangement of the pumping system and its impact on molecular back-streaming are discussed in detail. Molecular contamination measurements obtained with a TQCM and witness wafers during two recent integrated system tests of the chamber are presented and discussed. Finally, a concluding remarks section is presented.

  12. Results from a continuos control of the stability of standard ionization chambers

    International Nuclear Information System (INIS)

    The results from regular checks of measuring assembly performance constancy carried out in the period 1981-2000 for five Secondary Standard Chambers are presented. The test procedure consisted of 10 consecutive measurements of collected electrical charge for a time of 200 s each. For all chambers the percentage deviations are into the range of ± 1.5 %. For the whole period the average values of deviations are between 0.15 % and 0.14 %. The results for two chambers (2505/A SN 598 and NPL 2651 SN 096) in chronological succession are graph shown. The histograms of deviations for two other chambers (NE 2571 No. 238 and NE 2575 No. 118 are given. The deviations have a random character and due to dominant influence of some of the affecting quantities on given data. According to the international documents, the performance stability of the Secondary Standard ionization chambers is quite satisfactory

  13. Sensometrics for Food Quality Control

    DEFF Research Database (Denmark)

    Brockhoff, Per B.

    2011-01-01

    attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the fields of statistics, chemometrics and psychometrics. Some of the most commonly used sensory testing......The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...

  14. [Quality control of printed patient information].

    Science.gov (United States)

    Herm, Kerstin; Linden, Michael

    2013-05-01

    Printed material is an important part in patient information and is called bibliotherapy. It is subject to quality control similar to any other types of treatment. This paper presents an outline of important quality criteria and methods of quality control. Important quality criteria are: (a) Correctness and validity of content evaluated by mentioning the expertise of the authors, appraisal through external experts, reference to scientific literature, and empirical tests of the content, (b) Readability in respect to text structure measured by the "Flesch-Reading-Ease-Formula" supported by fair graphical design including fond and structure of text, (c) Comprehensibility tested by feedback of patients or standardized by the Hamburg comprehensibility rating, (d) Utility including securing availability, acceptance, differential indication and use. Writing and publication of patient leaflets must be accompanied by quality control measures. PMID:23446824

  15. Control mechanisms for assuring better IS quality:

    OpenAIRE

    Pivka, Marjan

    1998-01-01

    The software domain is faced with a number of quality assurance and process improvement models. Business managers are under pressure from many different kinds of assessments for their operations, products and services. Accounting departments are audited by financial auditors. What about information systems? Do we have a universal model on how to achieve required IS quality? This paper deals with the definition of IS quality and the influence of different control mechanisms on IS. The results ...

  16. PET/CT instrumentation: Quality assurance and quality control

    International Nuclear Information System (INIS)

    Improvement in quality assurance in Nuclear Medicine and in particular, in quality control of related equipment is a major field of interest of the International Atomic Energy Agency (IAEA). Several technical documents pertaining to scintigraphic imaging have been published and are being used as reference manuals by many professionals in the field (e.g., TECDOC 317, TECDOC 602, STI/PUB 1141). Positron emission tomography (PET) scanners and related performance assessment and quality control were not included in the previously published documents, as PET has been mainly a research tool, with limited worldwide distribution until the 90's. The tremendous role played presently by PET and PET/CT in whole-body oncology for lesion detection, staging and follow-up as well as the increasing role for PET in cardiology and neurology, associated with increasing reimbursement of multiple PET indications have prompted the need for updated guidelines specific to PET and PET/CT in terms of acceptance testing as well as quality control and assurance. The aim of this work is to present an overview of acceptance testing and quality assurance and control for PET and PET/CT

  17. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is sep

  18. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.)

  19. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  20. Production and quality control of iodine-123

    International Nuclear Information System (INIS)

    The various methods for production and quality control are discussed. The author feels the 123Xe-123I generator is the best method of production. Preparation and use of 123I-labeled compounds are also considered

  1. Quality Controlled Local Climatological Data (QCLCD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  2. Enclosed Chambers for Humidity Control And Sample Containment in Fiber Diffraction

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, M.; Kendall, A.; Tanaka, M.; Weissman, J.S.; Stubbs, G.

    2009-05-26

    A chamber and stretch frame for making fibers for diffraction is described. The chamber is made from a simple plastic cuvette with silicon nitride windows. It is suitable for maintaining constant humidity during fiber drying and data collection, and allows stretching of the fiber and exposure to magnetic fields during sample preparation. If necessary, it provides primary containment for toxic and infectious biological materials. The chamber has been used in fiber diffraction experiments with filamentous plant viruses and a yeast prion protein, and is shown to produce excellent orientation and to maintain hydration and order at the molecular level.

  3. Enclosed chambers for humidity control and sample containment in fiber diffraction

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, M.; Kendall, A.; Tanaka, M.; Weissman, J.S.; Stubbs, G. (Vanderbilt); (HHMI)

    2008-11-03

    A chamber and stretch frame for making fibers for diffraction is described. The chamber is made from a simple plastic cuvette with silicon nitride windows. It is suitable for maintaining constant humidity during fiber drying and data collection, and allows stretching of the fiber and exposure to magnetic fields during sample preparation. If necessary, it provides primary containment for toxic and infectious biological materials. The chamber has been used in fiber diffraction experiments with filamentous plant viruses and a yeast prion protein, and is shown to produce excellent orientation and to maintain hydration and order at the molecular level.

  4. Guidelines for quality control in digital fluoroscopy

    International Nuclear Information System (INIS)

    In the framework of European project DIMOND III, a document on quality control in digital fluoroscopy was drafted to offer means for equipment testing to ensure that specific requirements are fulfilled resulting in optimum image quality a minimum patient dose. The results are summarised in this paper. The work involves review of documents and publications in digital fluoroscopy equipment testing. The study takes into account not the efficiency of the tests but also their applicability in daily practice. The results are series of quality control tests and guidelines for evaluating systems used in fluoroscopically guided interventional procedures. (author)

  5. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  6. Quality control of the prostate tumor dosimetry performed by real-time dosimetry system COMPASS transmission chamber; Control de calidad de la dosimetria de tumores de prostata realizados mediante dosimetria en tiempo real con el sistema de camara de trasmision COMPASS

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, J. M.; Sanchez Cayuela, C.; Casal, M. d.; Pereza, C.; Brosed, M. L.; Sanchez, A.

    2011-07-01

    The most commonly used methodology for the verification of IMRT planning using radiochromic films and specific measures in a homogeneous phantom which move the control points of treatment. This system has the drawback of using a homogeneous model ignores the effect of the heterogeneities and the peculiarities of the patient's anatomy. This coupled with the fact obtain an evaluation in real time of each treatment fraction led us to use the new system COMPASS (I was Dosimetry) for the validation of planning.

  7. Development of the Experiment Control System and Performance Study of the Muon Chambers for the LHCb Experiment

    CERN Document Server

    Antunes Nobrega, R; Penso, G; Pinci, D

    2010-01-01

    The work of this thesis practically opened three fronts of the LHCb muon system : the development of the control and monitoring system of the readout electronics; the study of noise and threshold of the detector; and the study of the performance of the muon chambers. The LHCb muon readout apparatus is made 1368 Multi-Wire Proportional Chambers (MWPC) and 24 Gas Electron Multiplier (GEM) chambers connected to approximately 7500 16-channel front-end boards, resulting in 120000 output channels. The large-scale of this system naturally led to a complex control and monitoring system made of about 600 microcontrollers which are directly connected to the front-end electronics and handled by six computers. The development of this control system was accomplished within this thesis; the microcontroller’s firmware and the high level software, operating on the six local computers, were implemented. Besides configuring and monitoring the on-chamber readout electronics, a set of calibration and debugging oriented procedu...

  8. Quality control of dental radiohy at Iran

    International Nuclear Information System (INIS)

    A quality control program for dental radiography, in order to be sure that each radiographic operation with respect to its clinical difficulties to obtain images with high quality and gain proper information to be used in therapy with the lowest dose and cost is developed. In this program 20 radiography centers evaluated and parameters to control dose rate and images quality are considered. The results show inter oral films reduced to 408 and extra oral films reduced to 22 films in a week. The measured exposure from out coming of apparatus depends on various parameters which corrected errors is reduced to 5.35 m Sv.Unwanted exposure of operators and common people which occurred because of ignorance to the exposure is reduced to 0.88 m Sv and 1 m Sv in a week therefore, the importance of quality control program is obvious

  9. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  10. The engineering development of an actively controlled precise muon chamber for the SDC detector

    International Nuclear Information System (INIS)

    As the detector configuration for the Solenoidal Detector Collaboration (SDC) evolved, a number of concepts for MUON chambers were proposed and investigated. The Boston Group (Brandeis, Harvard and Tufts Universities, with Draper Laboratory) has developed a concept incorporating elliptical section drift tubes with field shaping and intermediate wire supports. This approach combines good single and multi-track resolution with a small channel count and modularity at the tube level. Other concepts have been developed which arise from differing interpretations of the fundamental physics and economic requirements. These include: Octagonal Drift Tubes, Unsupported Wires, No Field Shaping, U. Wisconsin; Round Tubes, Unsupported Wires, w or w/o Field Shaping, U. Washington; JFT Chambers (Multi-Wire, Intermediate Support, Field Shaping), KEK, Japan. This paper outlines the mechanical implementation of the Boston MUON chamber concept and discusses the rationale for several key design decisions imposed by the stringent mechanical tolerances. A prototype MUON chamber designed to verify design feasibility, performance, and cost is also described. A special section is devoted to the design and development of an optical alignment system within the chamber, which provides error signals driving the intermediate supports to true position. The Boston subgroup MUON chamber design is called the wine rack concept by virtue of its numerous (non-structural) drift tubes laid into a supporting chamber, which provides structural and handling capability. A number of individual θ,φ, and Stereo chambers is normally grouped into a supermodule, which in turn is assembled into a multi-layer supertower. Supertowers are the basic elements of the SDC MUON System, each comprising three supermodule layers in the barrel region and five in the forward regions

  11. Real-time Virtual Metrology and Control of Plasma Electron Density in an Industrial Plasma Etch Chamber

    OpenAIRE

    Lynn, Shane; MacGearailt, Niall; RINGWOOD John

    2011-01-01

    Plasma etching is a semiconductor manufacturing process during which material is removed from the surface of silicon wafers using gases in plasma form. A host of chemical and electrical complexities make the etch process notoriously dicult to model and troublesome to control. This work demonstrates the use of a real-time model predictive control scheme to maintain a consistent plasma electron density in the presence of disturbances to the ground path of the chamber. The electro...

  12. Quality control in 99m technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  13. Control and supervision of a time projection chamber with GEM readout

    International Nuclear Information System (INIS)

    To get a deeper understanding of the structure of nucleons and the strong interaction binding the constituents inside, the CBELSA/TAPS experiment investigates the resonance spectrum of baryons by meson photoproduction within the scope of the SFB/TRR 16 ''Subnuclear Structure of Matter''. In order to support and expand the physical program, the existing Inner Detector will be replaced by a Time Projection Chamber (TPC) within the next few years. This allows for the detection of charged reaction channels, which can't be measured with the CBELSA/TAPS experiment up to now, as well as for particle identification from the specific energy loss. A First prototype with GEM foils for charge amplification in front of the readout plane and suitable size for the CBELSA/TAPS experiment was built in collaboration with the TU Munich, the detector laboratory of the GSI in Darmstadt and the Stefan-Meyer-Institute of the University Vienna. The TPC has been commissioned successfully within the FOPI experiment at the GSI during several test beam campaigns. Additionally, systematic studies have been carried out with a smaller Test-TPC using a TestBench providing an accurate external track definition. As the electron drift velocity in the TPC volume is a crucial parameter for the exact track reconstruction, detailed simulations of the drift velocity and its dependency on external parameters, such as drift voltage, pressure, gas flow or temperature, have been carried out. The results of these simulations recommend a constant monitoring of all examined parameters to allow a reasonable use of the simulated drift velocities. For this purpose, and to ensure a safe and stable operation of the TPCs and the other detectors on the TestBench, the required hardware, the control software based on a data base and a graphical user interface were designed and constructed as the main part of this work. With this so-called SlowControl, it was possible to measure, control and store several parameters - e

  14. Study on the stability of waterpower-speed control system for hydropower station with air cushion surge chamber

    Science.gov (United States)

    Guo, W. C.; Yang, J. D.; Chen, J. P.; Teng, Y.

    2014-03-01

    According to the fact that the effects of penstock, unit and governor on stability of water level fluctuation for hydropower station with air cushion surge chamber are neglected in previous researches, in this paper, Thoma assumption is broken through, the complete mathematical model of waterpower-speed control system for hydropower station with air cushion surge chamber is established, and the comprehensive transfer function and linear homogeneous differential equation that characterize the dynamic characteristics of system are derived. The stability domain that characterizes the good or bad of stability quantitatively is drawn by using the stability conditions. The effects of the fluid inertia in water diversion system, the air cushion surge chamber parameters, hydraulic turbine characteristics, generator characteristics, and regulation modes of governor on the stability of waterpower-speed control system are analyzed through stability domain. The main conclusions are as follows: The fluid inertia in water diversion system and hydraulic turbine characteristics have unfavorable effects on the system while generator characteristics have favorable effect. The stability keeps getting better with the increase of chamber height and basal area and the decrease of air pressure and air polytropic exponent. The stability of power regulation mode is obviously better than that of frequency regulation mode.

  15. Study on the stability of waterpower-speed control system for hydropower station with air cushion surge chamber

    International Nuclear Information System (INIS)

    According to the fact that the effects of penstock, unit and governor on stability of water level fluctuation for hydropower station with air cushion surge chamber are neglected in previous researches, in this paper, Thoma assumption is broken through, the complete mathematical model of waterpower-speed control system for hydropower station with air cushion surge chamber is established, and the comprehensive transfer function and linear homogeneous differential equation that characterize the dynamic characteristics of system are derived. The stability domain that characterizes the good or bad of stability quantitatively is drawn by using the stability conditions. The effects of the fluid inertia in water diversion system, the air cushion surge chamber parameters, hydraulic turbine characteristics, generator characteristics, and regulation modes of governor on the stability of waterpower-speed control system are analyzed through stability domain. The main conclusions are as follows: The fluid inertia in water diversion system and hydraulic turbine characteristics have unfavorable effects on the system while generator characteristics have favorable effect. The stability keeps getting better with the increase of chamber height and basal area and the decrease of air pressure and air polytropic exponent. The stability of power regulation mode is obviously better than that of frequency regulation mode

  16. Precise and high-speed control of partial pressures of multiple gas species in plasma process chamber using pulse-controlled gas injection

    International Nuclear Information System (INIS)

    Multiprocesses in a single plasma process chamber with high throughput require precise, sequential, high-speed alteration of partial pressures of multiple gas species. A conventional gas-distribution system cannot realize this because the system seriously overshoots gas pressure immediately following valve operation. Furthermore, chamber volume and conductance of gas piping between the system and chamber should both be considered because they delay the stabilizing time of gas pressure. Therefore, the authors proposed a new gas-distribution system without overshoot by controlling gas flow rate based on pressure measurement, as well as a method of pulse-controlled gas injection immediately following valve operation. Time variation of measured partial pressure agrees well with a calculation based on an equivalent-circuit model that represents the chamber and gas piping between the system and chamber. Using pulse-controlled gas injection, the stabilizing time can be reduced drastically to 0.6 s for HBr added to pure Ar plasma, and 0.7 s for O2 added to Ar/HBr plasma; without the pulse control, the stabilizing times are 3 and 7 s, respectively. In the O2 addition case, rapid stabilization can be achieved during the period of line/space pattern etching of poly-Si on a thin SiO2 film. This occurs without anomalous etching of the underlying SiO2 film or the Si substrate near the sidewall, thus obtaining a wide process margin with high throughput.

  17. Budget-limited thermal biology: Design, construction and performance of a large, walk-in style temperature-controlled chamber.

    Science.gov (United States)

    Martinez, Eloy; Agosta, Salvatore J

    2016-05-01

    We describe a partial redesign of the conventional air-conditioning system and apply it to the construction of a relatively large (1.87m(3) air mass), walk-in style temperature-controlled chamber (TCC) using parts easily obtained in most countries. We conducted several tests to demonstrate the performance of the TCC. Across the physiologically relevant range of 5-37°C, the TCC took 26.5-50.0min to reach the desired set point temperature. Once at set point, temperature inside the chamber was controlled with an accuracy of ±1.0°C. User-entry effects on deviations from and return times to set point temperature were minimal. Overall, performance of the TCC was sufficient to make precise physiological measurements of insect metabolic rate while controlling assay temperature. Major advantages of the TCC include its simplicity, flexibility, and low cost. PMID:27157331

  18. Quality control of cadweld (mechanical) splices

    International Nuclear Information System (INIS)

    Test data for cadweld splicing of reinforcing steel collected during a study of quality assurance practices on nine nuclear power plant construction projects are presented and evaluated. These data lead to an important hypothesis that the visual inspection identifies procedural deficiencies, and the tensile test identifies material defects. It is also suggested that a material testing program and the visual inspection will detect essentially all substandard cadwell splices. This would permit the deletion of the expensive tensile testing program. Accordingly, most quality control programs require overtesting and overdocumentation of cadweld splices; and furthermore, these programs fail to recognize material defects. The project specifications and quality control requirements for the nine projects are compared. Where possible, these are evaluated against the industry standards and Federal regulations. It is shown that there are a number of deficiencies in these standards, and that in most cases, the testing requirements are not commensurate with the quality that is being achieved in the field

  19. Quality control of a teleradiology system

    Science.gov (United States)

    Lyche, David K.; Willis, Charles E.; Williamson, Morgan P.; Suitor, Charles T.; Romlein, John R.

    1996-04-01

    Teleradiology is being implemented in the U.S. military. Soft-copy reading of computed radiology (CR) images and film-digitizer (FD) images are becoming a common practice. The Medical Diagnostic Imaging Support (MDIS) Office at the Medical Advanced Technology Management Office (MATMO), Fort Detrick, Maryland, installed an 'off-the-shelf' DICOM teleradiology system by which CR images and FD images acquired at Hickam Air Force Base (AFB), Hawaii, are transmitted electronically over a T-1 telecommunications line to Tripler Army Medical Center (TAMC), Hawaii. The goal was to provide a diagnostic quality teleradiology system to the military services to extend the expertise and training of physicians to remote sites. In order to guarantee a diagnostic quality image throughout the system, a rigid set of quality control standards had to be designed and implemented. This poster presents the results of a successful teleradiology implementation where quality control is maintained throughout the imaging chain.

  20. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  1. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  2. Quality Control of Wild Berries Honey Syrup

    Directory of Open Access Journals (Sweden)

    Laura Stan

    2013-11-01

    Full Text Available This paper presents the quality control parameters of wild berries honey syrup . The product was created in laboratory (wild berries: honey, 1:4 w/w and there were no changes recorded in overall quality over 6 months preservation at 1-2°C. Basic quality parameters of the product were evaluated: humidity, pH, acidity, hydroxymethylfurfural, diastase, total sugars and ascorbic acid. Methods developed by Internantional Honey Commission and Romanian Food Quality Standards were applied during this study. The product presented qood quality criteria and it was highly appreciated by consumers who tasted it. This study presents a valuable method to preserve fresh widberries in honey over a long period of time. The economical value of this experiment resides in making these fruits available outside the harvesting season.

  3. Quality control in diagnostic radiology - patient dosimetry

    International Nuclear Information System (INIS)

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author)

  4. Harmonisation Initiatives of Copernicus Data Quality Control

    Science.gov (United States)

    Vescovi, F. D.; Lankester, T.; Coleman, E.; Ottavianelli, G.

    2015-04-01

    The Copernicus Space Component Data Access system (CSCDA) incorporates data contributions from a wide range of satellite missions. Through EO data handling and distribution, CSCDA serves a set of Copernicus Services related to Land, Marine and Atmosphere Monitoring, Emergency Management and Security and Climate Change. The quality of the delivered EO products is the responsibility of each contributing mission, and the Copernicus data Quality Control (CQC) service supports and complements such data quality control activities. The mission of the CQC is to provide a service of quality assessment on the provided imagery, to support the investigation related to product quality anomalies, and to guarantee harmonisation and traceability of the quality information. In terms of product quality control, the CQC carries out analysis of representative sample products for each contributing mission as well as coordinating data quality investigation related to issues found or raised by Copernicus users. Results from the product analysis are systematically collected and the derived quality reports stored in a searchable database. The CQC service can be seen as a privileged focal point with unique comparison capacities over the data providers. The comparison among products from different missions suggests the need for a strong, common effort of harmonisation. Technical terms, definitions, metadata, file formats, processing levels, algorithms, cal/val procedures etc. are far from being homogeneous, and this may generate inconsistencies and confusion among users of EO data. The CSCDA CQC team plays a significant role in promoting harmonisation initiatives across the numerous contributing missions, so that a common effort can achieve optimal complementarity and compatibility among the EO data from multiple data providers. This effort is done in coordination with important initiatives already working towards these goals (e.g. INSPIRE directive, CEOS initiatives, OGC standards, QA4EO

  5. Evaluating quality control of Wikipedia's feature articles

    OpenAIRE

    Lindsey, David

    2010-01-01

    The purpose of this study was to evaluate the effectiveness of Wikipedia’s internal quality control mechanism, the “featured article” process, which assesses articles against a stringent set of criteria. To this end, scholars were asked to evaluate the quality and accuracy of Wikipedia featured articles within their area of expertise. A total of 22 usable responses were collected from a variety of disciplines. Out of the Wikipedia articles assessed, only 12 of 22 were found to pass Wikiped...

  6. Quality assurance/quality control for testing of radioactivity

    International Nuclear Information System (INIS)

    The Testing laboratory of material radioactivity was founded in 1999 on the basis of former Nuclear Research Centre. The primary aim was to test the waste, radioactive polluted materials and apparatus from the shut down nuclear reactor. In 2000 National Accreditation Service of Latvia (LATAK) accredited laboratory. In the following years the enlargement of testing sphere occurred. The aim of this work is the introduction of quality assurance and quality control according to ISO/IEC 17025 standard in the Testing laboratory of material radioactivity State Enterprise 'RAPA' in Salaspils, Latvia. Radioactivity of Cs-137, Co-60, U-238 and Th-232 trees, as well as other radionuclides is measured using the high performance gamma-spectrometry. Testing of different environmental samples and building materials as well as samples irradiated with neutron flux of nuclear reactor and radioactive polluted objects is carried out. Alfa- and beta-radioactivity of waters is tested using OXFORD Tennelec Solo counting system. Other equipment is used to test the radioactive contaminated surfaces, the testing of tritium activity is done with LSC. The 4 year work period on the quality control and quality assurance of the laboratory and the participation in the intercalibration measurements allowed: - to get the laboratory accreditation according to ISO/IEC 17025 standard; - to enlarge the sphere of activities (introducing new methods); - to increase the number of clients; - to increase the number of tested samples from 124 in 2000 to 600 in the 8 months of the year 2003. (authors)

  7. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.;

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system. The...... particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  8. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    To study the quality control of 11C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  9. Protein quality control in the bacterial periplasm.

    Science.gov (United States)

    Merdanovic, Melisa; Clausen, Tim; Kaiser, Markus; Huber, Robert; Ehrmann, Michael

    2011-01-01

    Protein quality control involves sensing and treatment of defective or incomplete protein structures. Misfolded or mislocalized proteins trigger dedicated signal transduction cascades that upregulate the production of protein quality-control factors. Corresponding proteases and chaperones either degrade or repair damaged proteins, thereby reducing the level of aggregation-prone molecules. Because the periplasm of gram-negative bacteria is particularly exposed to environmental changes and respective protein-folding stresses connected with the presence of detergents, low or high osmolarity of the medium, elevated temperatures, and the host's immune response, fine-tuned protein quality control systems are essential for survival under these unfavorable conditions. This review discusses recent advances in the identification and characterization of the key cellular factors and the emerging general principles of the underlying molecular mechanisms. PMID:21639788

  10. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  11. Controlled environment fumigation chambers for the study of reactive air pollutant effects on plants

    Science.gov (United States)

    Stokes, N. J.; Lucas, P. W.; Nicholas Hewitt, C.

    The design and construction of eight 1-m 3 fumigation chambers for exposing plants to reactive air pollutants at low concentrations are reported. Teflon surfaces are used where possible to minimize the adsorption, absorption, desorption and chemical reaction of the pollutants. A purified ambient air supply, to which metered quantities of gaseous pollutants are added, is used to give two air changes per minute at constant, low, pollutant concentrations. Comparative analysis of the chambers indicates that conditions may be maintained with a significant degree of precision, i.e. temperature ±0.3°C, RH ±6%, light intensity ±5 μmol m -2 s -1. Boundary layer analysis from models of cherry tree ( Prunus avium) leaves indicate that the minimum conductance value within these chambers is 2 cm s -1.

  12. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  13. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  14. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  15. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  16. Role of dosimetry in quality control

    International Nuclear Information System (INIS)

    Dosimetry plays an important role in the quality control of radiation processing. Increasingly, quality control systems are based on the standards in the 9000 series from the International Organization for Standardization, ISO. This is true not only in radiation sterilization but also in food treatment, polymer modification and other uses of radiation. It is required that all measurements - including radiation measurements -are traceable to national standards, and the uncertainty of the measurements must be stated with appropriate confidence limits. The paper discusses the significance of dosimetry, the evaluation of uncertainty, and the way in which traceability may be obtained. (author). 11 refs, 2 tabs

  17. Quality Control of Reference Standard Source Production

    International Nuclear Information System (INIS)

    Full text: The preparation techniques of sealed I-131 sources for calibrating gamma ray spectrometry were developed by gravimetric dispensing the reference I-131 solution. Following the production techniques and quality control according to IAEA-TECDOC-1512, four methods including wipe test, impact test, leakage and homogeneity test were employed to demonstrate sealed radioactive sources. The half-life was determined by imaging plate system and found to be 8.10 ± 0.02 days in agreement with the decay theory. The techniques may be useful for quality control of reference standard source production

  18. Emulsion Chamber Technology Experiment (ECT)

    Science.gov (United States)

    Gregory, John C.; Takahashi, Yoshiyuki

    1996-01-01

    The experimental objective of Emulsion Chamber Technology (ECT) was to develop space-borne emulsion chamber technology so that cosmic rays and nuclear interactions may subsequently be studied at extremely high energies with long exposures in space. A small emulsion chamber was built and flown on flight STS-62 of the Columbia in March 1994. Analysis of the several hundred layers of radiation-sensitive material has shown excellent post-flight condition and suitability for cosmic ray physics analysis at much longer exposures. Temperature control of the stack was 20 +/-1 C throughout the active control period and no significant deviations of temperature or pressure in the chamber were observed over the entire mission operations period. The unfortunate flight attitude of the orbiter (almost 90% Earth viewing) prevented any significant number of heavy particles (Z greater than or equal to 10) reaching the stack and the inverted flow of shower particles in the calorimeter has not allowed evaluation of absolute primary cosmic ray-detection efficiency nor of the practical time limits of useful exposure of these calorimeters in space to the level of detail originally planned. Nevertheless, analysis of the observed backgrounds and quality of the processed photographic and plastic materials after the flight show that productive exposures of emulsion chambers are feasible in low orbit for periods of up to one year or longer. The engineering approaches taken in the ECT program were proven effective and no major environmental obstacles to prolonged flight are evident.

  19. Tests of the data acquisition system and detector control system for the muon chambers of the CMS experiment at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Michael Christian

    2009-02-27

    The Phys. Inst. III A of RWTH Aachen University is involved in the development, production and tests of the Drift Tube (DT) muon chambers for the barrel muon system of the CMS detector at the LHC at CERN (Geneva). The present thesis describes some test procedures which were developed and performed for the chamber local Data Acquisition (DAQ) system, as well as for parts of the Detector Control System (DCS). The test results were analyzed and discussed. Two main kinds of DAQ tests were done. On the one hand, to compare two different DAQ systems, the chamber signals were split and read out by both systems. This method allowed to validate them by demonstrating, that there were no relevant differences in the measured drift times, generated by the same muon event in the same chamber cells. On the other hand, after the systems were validated, the quality of the data was checked. For this purpose extensive noise studies were performed. The noise dependence on various parameters (threshold,HV) was investigated quantitatively. Also detailed studies on single cells, qualified as ''dead'' and ''noisy'' were done. For the DAQ tests a flexible hardware and software environment was needed. The organization and installation of the supplied electronics, as well as the software development was realized within the scope of this thesis. The DCS tests were focused on the local gas pressure read-out components, attached directly to the chamber: pressure sensor, manifolds and the pressure ADC (PADC). At first it was crucial to proof, that the calibration of the mentioned chamber components for the gas pressure measurement is valid. The sensor calibration data were checked and possible differences in their response to the same pressure were studied. The analysis of the results indicated that the sensor output depends also on the ambient temperature, a new experience which implied an additional pedestal measurement of the chamber gas pressure

  20. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  1. Design and implementation of a three axis digitally controlled traverse system for flow surveys in a drying chamber

    OpenAIRE

    Achilleas Bardakas; Vasilis Chasiotis; Dimitrios Tzempelikos; Andronikos Filios

    2014-01-01

    The current paper describes the design and development of a pc-controlled three axis traverse system that aims to serve extensive velocity and temperature measurements into the drying chamber of a laboratory scale convective dryer. The traversing gear design has been conducted based on the convective dryer’s specific experimental requirements and limitations. The fabricated traversing gear uses a trapezoidal lead screw-nut assembly supported by linear ball bearings, coupled with bipolar stepp...

  2. Evaluation tools of quality control for patients submitted to IMRT

    International Nuclear Information System (INIS)

    Intensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of +-3% dose difference and +-3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about +- 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in 'sliding-window' IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively. (author)

  3. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  4. Guidelines for radriopharmaceutical quality control in hospitals

    International Nuclear Information System (INIS)

    This document has been prepared to assist hospital administrators in ensuring that adequate quality control is performed on radiopharmaceuticals administered to their patients. Three sets of guidelines are presented, the degree of sophistication being dependent on the amount of hospital involvement in the radiopharmaceutical preparation

  5. Water quality control program in experimental circuits

    International Nuclear Information System (INIS)

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  6. Quality Control Of Selected Pesticides With GC

    International Nuclear Information System (INIS)

    The practical quality control of selected pesticides with GC is treated. Detailed descriptions are given on materials and methods used, including sample preparation and GC operating conditions. The systematic validation of multi methods is described, comprising performance characteristics in routine analysis, like selectivity, specificity etc. This is illustrated by chromatograms, calibration curves and tables derived from real laboratory data. (author)

  7. Materials, methods and quality control, ch. 3

    International Nuclear Information System (INIS)

    A description of the chemical reagents, the 125I-labelled angiotensin I, the antiserum and the standards is given. A modified measuring method with the New England Nuclear kit for angiotensin I radioimmunoassay is presented as well as the quality control data

  8. Influence analysis of the variations on quality control parameters in determination of absorbed dose in water

    International Nuclear Information System (INIS)

    The reference condition established to determine the absorbed dose in water of a linear accelerator, according to TRS-398, depends on some electro-mechanics parameters. Furthermore, in principle, uncertainties in the parameters settings may results in dosimetry variations. The goal of this study is to analyze the influence in quality control parameters changes, which tolerance limits are established by TECDOC-1151, in the dosimetry result of photon beam. For this, some parameters (gantry and collimator angle, field size and source to surface distance) and chamber position were changed. The results of these changes were evaluated. For the variation range of quality control items (that went beyond the tolerance limits established by TECDOC-1151), the deviations got less than 1 % of reference for all analyzed parameters; the deviations for the ionization chamber position variation were less than 0,2 % for lateral and longitudinal variations although almost got to 3 % for depth alterations. (author)

  9. Influence analysis of the variations on quality control parameters in determination of absorbed dose in water

    International Nuclear Information System (INIS)

    The reference condition established to determine the absorbed dose in water of a linear accelerator, according to Tars-398, depends on some electro-mechanics parameters. Furthermore, in principle, uncertainties in the parameters settings may results in dosimetry variations. The goal of this study is to analyze the influence in quality control parameters changes, which tolerance limits are established by TECDOC-1151, in the dosimetry result of photon beam. For this, some parameters (gantry and collimator angle, field size and source to surface distance) and chamber position were changed. The results of these changes were evaluated. For the variation range of quality control items (that went beyond the tolerance limits established by TECDOC-1151), the deviations got less than 1 % of reference for all analyzed parameters; the deviations for the ionization chamber position variation were less than 0,2 % for lateral and longitudinal variations although almost got to 3% for depth alterations. (author)

  10. Statistical quality control through overall vibration analysis

    Science.gov (United States)

    Carnero, M. a. Carmen; González-Palma, Rafael; Almorza, David; Mayorga, Pedro; López-Escobar, Carlos

    2010-05-01

    The present study introduces the concept of statistical quality control in automotive wheel bearings manufacturing processes. Defects on products under analysis can have a direct influence on passengers' safety and comfort. At present, the use of vibration analysis on machine tools for quality control purposes is not very extensive in manufacturing facilities. Noise and vibration are common quality problems in bearings. These failure modes likely occur under certain operating conditions and do not require high vibration amplitudes but relate to certain vibration frequencies. The vibration frequencies are affected by the type of surface problems (chattering) of ball races that are generated through grinding processes. The purpose of this paper is to identify grinding process variables that affect the quality of bearings by using statistical principles in the field of machine tools. In addition, an evaluation of the quality results of the finished parts under different combinations of process variables is assessed. This paper intends to establish the foundations to predict the quality of the products through the analysis of self-induced vibrations during the contact between the grinding wheel and the parts. To achieve this goal, the overall self-induced vibration readings under different combinations of process variables are analysed using statistical tools. The analysis of data and design of experiments follows a classical approach, considering all potential interactions between variables. The analysis of data is conducted through analysis of variance (ANOVA) for data sets that meet normality and homoscedasticity criteria. This paper utilizes different statistical tools to support the conclusions such as chi squared, Shapiro-Wilks, symmetry, Kurtosis, Cochran, Hartlett, and Hartley and Krushal-Wallis. The analysis presented is the starting point to extend the use of predictive techniques (vibration analysis) for quality control. This paper demonstrates the existence

  11. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  12. Computational and experimental research of internal combustion engine with spark ignition and quality power level control

    OpenAIRE

    О. П. Домбровский; Р. Ф. Зиннатуллин; Е. Г. Стругова

    2013-01-01

    The article presents the methodology of injection and combustion processes simulation in the internal combustion engine with unified working process. The results of computational study of injection and combustion processes in the combustion chamber of experimental two-stroke engine are presented. The possibility of full-range quality power level control and full fuel-burning is experimentally and computationally shown on two-stroke gasoline engine, the results of study are presented. Reducing...

  13. Characterization tests of a homemade ionization chamber in mammography standard radiation beams

    International Nuclear Information System (INIS)

    A mammography homemade ionization chamber was developed to be applied for mammography energy range dosimetry. This chamber has a sensitive volume of 6 cm3 and is made of a Lucite body and graphite coated collecting electrode. Characteristics such as saturation, ion collection efficiency, linearity of chamber response versus air kerma rate and energy dependence were determined. The results obtained with the mammography homemade ionization chamber are within the limits stated in international recommendations. This chamber can be used in quality control programs in the diagnostic radiology area. All measurements were carried out at the Calibration Laboratory of IPEN. - Highlights: • We constructed a mammography homemade ionization chamber. It was submitted to standard mammography X-rays beam qualities. • The results obtained showed good agreement with international standards. • This chamber can be used in quality control programs of diagnostic radiology area

  14. 42 CFR 84.41 - Quality control plans; contents.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for...

  15. Adaptive quality control for multimedia communications

    OpenAIRE

    Santichai Chuaywong; Sinchai Kamolphiwong; Thossaporn Kamolphiwong; Kevin Robert Elz; Suthon Sae-Wong

    2008-01-01

    Multimedia communications are communications with several types of media, such as audio, video and data. The current Internet has some levels of capability to support multimedia communications, unfortunately, the QoS (Quality of Service) is still challenging. A large number of QoS mechanisms has been proposed; however, the main concern is for low levels, e.g. layer 2 (Data Link) or 3 (Transport). In this paper, mechanisms for control the quality of audio and video are proposed. G.723.1 and MP...

  16. Quality and Control of Water Vapor Winds

    Science.gov (United States)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  17. Automation and instrument control applied to an experimental study of electron transport dynamics in an avalanche mode resistive plater chamber

    International Nuclear Information System (INIS)

    In this work it is presented a computer based instrumentation system which was developed to perform data acquisition and integrate the control of different devices in an experimental study of electron transport dynamics in an avalanche mode resistive plate chamber detector in the Radiation Technology Center (CTR) at IPEN/CNEN-SP. System control and data acquisition was performed by a computer program called RPCLabOperator written in MatLab environment running on a LeCroy WavePro 7000 digital oscilloscope. (author)

  18. Design and Implementation of the Frequency Control in an Ultrasonic Break Water-in-Oil Emulsion Chamber

    Science.gov (United States)

    Atehortúa, Carlos Mario Giraldo; Pérez, Nicolás; Andrade, Marco Aurelio Brizzotti; Adamowski, Julio Cezar; Pereira, Luiz Octávio Vieira

    Water-in-oil emulsions present high stability and its separation is commonly accelerated by addition of chemical demulsifiers or using electrostatic techniques. An alternative to reduce the amount of demulsifiers is the use of ultrasonic standing waves. In this work, the design and implementation of an ultrasonic demulsifier system operating in the 1 MHz range is presented. The design includes the ultrasonic resonant chamber, the power electronics to drive the piezoelectric transducers and the control system. The control must track the operating frequency, compensating the changes due to temperature variation. The system was evaluated in a laboratory pipeline showing that the use of ultrasound reduces the final water content in all cases.

  19. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  20. Laboratory quality control based on risk management.

    Science.gov (United States)

    Nichols, James H

    2011-01-01

    Risk management is the systematic application of management policies, procedures, and practices to the tasks of analyzing, evaluating, controlling and monitoring risk (the effect of uncertainty on objectives). Clinical laboratories conduct a number of activities that could be considered risk management including verification of performance of new tests, troubleshooting instrument problems and responding to physician complaints. Development of a quality control plan for a laboratory test requires a process map of the testing process with consideration for weak steps in the preanalytic, analytic and postanalytic phases of testing where there is an increased probability of errors. Control processes that either prevent or improve the detection of errors can be implemented at these weak points in the testing process to enhance the overall quality of the test result. This manuscript is based on a presentation at the 2nd International Symposium on Point of Care Testing held at King Faisal Specialist Hospital in Riyadh, Saudi Arabia on October 12-13, 2010. Risk management principles will be reviewed and progress towards adopting a new Clinical and Laboratory Standards Institute Guideline for developing laboratory quality control plans based on risk management will be discussed. PMID:21623049

  1. Laboratory quality control based on risk management

    Directory of Open Access Journals (Sweden)

    Nichols James

    2011-01-01

    Full Text Available Risk management is the systematic application of management policies, procedures, and practices to the tasks of analyzing, evaluating, controlling and monitoring risk (the effect of uncertainty on objectives. Clinical laboratories conduct a number of activities that could be considered risk management including verification of performance of new tests, troubleshooting instrument problems and responding to physician complaints. Development of a quality control plan for a laboratory test requires a process map of the testing process with consideration for weak steps in the preanalytic, analytic and postanalytic phases of testing where there is an increased probability of errors. Control processes that either prevent or improve the detection of errors can be implemented at these weak points in the testing process to enhance the overall quality of the test result. This manuscript is based on a presentation at the 2nd International Symposium on Point of Care Testing held at King Faisal Specialist Hospital in Riyadh, Saudi Arabia on October 12-13, 2010. Risk management principles will be reviewed and progress towards adopting a new Clinical and Laboratory Standards Institute Guideline for developing laboratory quality control plans based on risk management will be discussed.

  2. Design and implementation of a three axis digitally controlled traverse system for flow surveys in a drying chamber

    Directory of Open Access Journals (Sweden)

    Achilleas Bardakas

    2014-06-01

    Full Text Available The current paper describes the design and development of a pc-controlled three axis traverse system that aims to serve extensive velocity and temperature measurements into the drying chamber of a laboratory scale convective dryer. The traversing gear design has been conducted based on the convective dryer’s specific experimental requirements and limitations. The fabricated traversing gear uses a trapezoidal lead screw-nut assembly supported by linear ball bearings, coupled with bipolar stepper motors for positioning in three dimensional spaces. A custom drive system solution was selected for achieving accurate motor control, paired with computer software developed using the LabVIEW® graphical programming environment. The functionality of the traversing system was experimentally verified by testing mechanical and electronic assemblies, but also by determining the per axis positioning error. Keywords: Fluid Flow Measurement, Digital Control, Motion Control, Displacement Control, Electromechanical Devices.

  3. Protein quality control in the nucleus.

    Science.gov (United States)

    Jones, Ramon D; Gardner, Richard G

    2016-06-01

    The nucleus is the repository for the eukaryotic cell's genetic blueprint, which must be protected from harm to ensure survival. Multiple quality control (QC) pathways operate in the nucleus to maintain the integrity of the DNA, the fidelity of the DNA code during replication, its transcription into mRNA, and the functional structure of the proteins that are required for DNA maintenance, mRNA transcription, and other important nuclear processes. Although we understand a great deal about DNA and RNA QC mechanisms, we know far less about nuclear protein quality control (PQC) mechanisms despite that fact that many human diseases are causally linked to protein misfolding in the nucleus. In this review, we discuss what is known about nuclear PQC and we highlight new questions that have emerged from recent developments in nuclear PQC studies. PMID:27015023

  4. Quality control of nuclear medicine equipment

    International Nuclear Information System (INIS)

    In order to determine functional status and integrity of installations and equipment used in nuclear medicine in everyday medical practice or in research studies, it is important to maintain and implement quality control program. For this type of installation are required high standards, particularly with regard to qualitative and quantitative analysis of the image, and volume measurements in diagnosis and dosimetry. Given the precarious situation of the economy in transition, nuclear medicine departments in the republic, now, can not be always of service contracts with providers of facilities and equipment for routine maintenance and periodic calibration. Therefore, in this article are at some of the quality control procedures should be performed usually by engineers and physicists from the department of nuclear medicine. (authors)

  5. Quality Control in Dental Radiology in Greece

    International Nuclear Information System (INIS)

    Quality control was implemented in 52 dental intra-oral X ray units in use in the public and private sector in Hellas. The protocol consisted of visual inspection of the X ray unit, complete registration of the unit's characteristics, measurement of the unit's radiological parameters, inspection of the radiation protection facilities for patient and personnel and examination of film processing conditions. The results are characterised by the large number of old X ray units, the great variability in entrance surface doses and linearity of output and the absence of strict patient and operator radiation protection measures. Analogue exposure timers have very poor accuracy compared to digital ones. Imaging techniques and film processing do not always comply with standards among dentists. In view of the above, the implementation of a Quality Control programme, including reference doses, which could, for example, be selected according to the results of this paper, is strongly recommended in Dental Radiology in Hellas. (author)

  6. Progress in gamma-camera quality control

    International Nuclear Information System (INIS)

    The latest developments in the art of quality control of gamma cameras are emphasized in a simple historical manner. The exhibit describes methods developed by the Bureau of Radiological Health (BRH) in comparison with previously accepted techniques for routine evaluation of gamma-camera performance. Gamma cameras require periodic testing of their performance parameters to ensure that their optimum imaging capability is maintained. Quality control parameters reviewed are field uniformity, spatial distortion, intrinsic and spatial resolution, and temporal resolution. The methods developed for the measurement of these parameters are simple, not requiring additional electronic equipment or computers. The data has been arranged in six panels as follows: schematic diagrams of the most important test patterns used in nuclear medicine; field uniformity; regional displacements in transmission pattern image; spatial resolution using the BRH line-source phantom; instrinsic resolution using the BRH Test Pattern; and Temporal resolution and count losses at high counting rates

  7. AQCS: Analytical Quality Control Services intercomparison runs

    International Nuclear Information System (INIS)

    This document describes an interlaboratory comparison exercise run by the IAEA and includes description of the intercomparison material, scope of the study, quality control requirements and reporting requirements including reporting forms and questionnaires. The intercomparison material is homogenized soil and participants are requested using their established and proven analytical techniques to measure six radioisotopes: K-40, Sr-90, Cs-134, Cs-137, and Pu-239. The document also contains the results obtained and their interpretation

  8. The software quality control for gamma spectrometry

    International Nuclear Information System (INIS)

    One of major problems with wich the quality control program of an environmental measurements laboratory is confronted is the evaluation of the performances of software packages for the analysis of gamma-ray spectra. A program of tests for evaluating the performances of the software package (SPECTRAN-F, Canberra Inc.) used by our laboratory is being carried out. In this first paper the results of a preliminary study concerning the evaluation of the performance of the doublet analysis routine are presented

  9. Quality control in the year 2000

    OpenAIRE

    Schade, Bernd

    1992-01-01

    ‘Just-in-time’ production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and pro...

  10. Applying GPS to check horizontal control quality

    OpenAIRE

    Jakub Vincent; Weiss Gabriel; Sabová Jana

    2004-01-01

    GPS technologies can also be used for check quality in available horizontal point set with coordinates CJ of the frame S-JTSK. When survey and setting-out tasks should be performed in certain area, one can found in it allways some points of the fundamental and detail state controls. To use these points for some actual aims, it is necessary to investigate their compatibility (among the point mark positions and the point coordinate of control points). This can be done using GPS surveying that m...

  11. Glycoprotein Quality Control and Endoplasmic Reticulum Stress

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2015-07-01

    Full Text Available The endoplasmic reticulum (ER supports many cellular processes and performs diverse functions, including protein synthesis, translocation across the membrane, integration into the membrane, folding, and posttranslational modifications including N-linked glycosylation; and regulation of Ca2+ homeostasis. In mammalian systems, the majority of proteins synthesized by the rough ER have N-linked glycans critical for protein maturation. The N-linked glycan is used as a quality control signal in the secretory protein pathway. A series of chaperones, folding enzymes, glucosidases, and carbohydrate transferases support glycoprotein synthesis and processing. Perturbation of ER-associated functions such as disturbed ER glycoprotein quality control, protein glycosylation and protein folding results in activation of an ER stress coping response. Collectively this ER stress coping response is termed the unfolded protein response (UPR, and occurs through the activation of complex cytoplasmic and nuclear signaling pathways. Cellular and ER homeostasis depends on balanced activity of the ER protein folding, quality control, and degradation pathways; as well as management of the ER stress coping response.

  12. Anterior chamber depth and lens thickness in primary angle-closure glaucoma : A case-control study

    Directory of Open Access Journals (Sweden)

    Saxena Sandeep

    1993-01-01

    Full Text Available Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma (PACG. In a tertiary care centre-based case-control study, 70 patients and equal number of controls were investigated to analyse the strength of association and predictability of anterior chamber depth (ACD and lens thickness (LT in the disease. Mean (+/- S.D. ACD and LT in the cases and the controls were found to be 2.28 +/- 0.19, 2.87 +/- 0.10; 4.57 +/- 0.34 and 4.13 +/- 0.19 mm respectively. Two sample t test demonstrated statistically significant difference in the ACD and LT between the cases and the controls (Difference being -0.59, 0.44; 95% confidence interval of the difference: -0.64, -0.53 and 0.34, 0.53 respectively, P < 0.01. Logistic regression analysis demonstrated statistically significant protective effect of ACD over PACG (P < 0.01. The odds ratio corresponding to an increase of 0.01 mm in ACD and LT were computed as 0.83 and 1.11 respectively

  13. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on...

  14. Quality assurance and control, simply a must

    International Nuclear Information System (INIS)

    Full text: At the low level tritium laboratory Arsenal the work with isotopes started in the 1960s. At that time quality control or assurance were words not used very frequently or simply not known and until the 1980s this situation did not change. But running a laboratory without any control or working directions does not make sense as customers who received doubtful results can not be expected to submit further samples for analyses to that institute. At the time before a controlled quality assurance system was established and before ACCESS or ORACLE appeared a database was programmed to host all relevant sample data. All samples run through the preparation steps identified by a unique sample number assigned by the database program during the registration process. The liquid scintillation counters were attached to a mainframe computer with the help of which the final calculations were done. Lists of background and efficiency values were and still are updated after each calculation in the form of control charts and deviations from expected system characteristics are easily visible. In the year 1993 the research centre applied for the certification according to ISO 9001. In the course of this process a quality management handbook containing information about the department's activities and personal structure and the responsibilities as well. In a series of working instructions all procedures were documented and the persons in charge had to approve he knowledge about these instruction by their signature. In 1996 the centre was certified. After the certification audit regular internal audit were and are performed to guarantee the quality of the results leaving our laboratory. In a next step the centre applied for accreditation and in 1998 the accreditation was granted by the ministry responsible. In 2003 we passed the first reaudit with success. An important part of quality control plays a laboratory intercomparison. As part of our quality management system we

  15. Quality control beam of radiation through imaging system using a flat panel (ILD)

    International Nuclear Information System (INIS)

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  16. Development of a calibration methodology for instruments used to interventional radiology quality control

    International Nuclear Information System (INIS)

    Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well established rules to determine the doses and to make the dosimetry in fluoroscopic beams. There is great interest in this study, in relation to the beam quality, the half-value-layer, and others parameters. In this work a Medicor Neo Diagnomax clinical X ray generator, fluoroscopy mode, was used to develop a calibration methodology for instruments used in interventional radiology quality control. One plane parallel ionization chamber PTW was used as monitor. The ionization chambers recommended for fluoroscopy measurements had been evaluated and calibrated in relation to the IPEN Calibration Laboratory reference ionization chamber. The RQR3, RQR5 and RQR7 radiation qualities and the specific ones for fluoroscopy, RQC3, RQC5 and RQC7, were established following the norm IEC 61267. All beams characteristics were determined. Ionization chambers positioning system and the acrylic phantoms to the entrance and exit doses determination were developed and constructed. The results obtained show air kerma rates of 4.5x10-3, 1.2x10-2 and 1.9x10-2 Gy/min for RQC3, RQC5 and RQC7 respectively. Tests with and without the collimation just after the monitor chamber, were carried out and the results showed a difference of +5.5%, +0.6% e + 0.8%, confirming the importance of the collimation use in these interventionist procedures. (author)

  17. Some studies on the fission of uranium with the help of a self-controlled wilson chamber

    International Nuclear Information System (INIS)

    The authors applied the method of Wilson's chamber self intern control to the survey of the uranium fission with neutrons of the core. This method allowed them: 1) - to establish a distribution of the courses of the fission fragments in argon on a big number of events. 2) - to search for the probability of production of tri-partitions to third fragment of short course. The authors succeed to the conclusion that in relation to ordinary fission, this, probability is lower to (1 ± 3)/1000, what permits to doubt the existence of the phenomenon. (author)

  18. The IAEA's programme on analytical quality control

    International Nuclear Information System (INIS)

    In the early 1960s, the IAEA decided to launch a programme for the assessment of the reliability of low level radiochemical analysis and since then, the Analytical Quality Control Services (AQCS) has developed into a major organiser of world-wide intercomparison runs. Over the intervening years, the types of matrices studied and the analytes of interest have been extended beyond the limits of radioactivity measurements to encompass: trace elements, organic contaminants, stable isotopes and methyl mercury. The Agency provides assistance to its Member States through the AQCS programme to improve the standard of analytical results in their laboratories. These results must be of a certain quality (i.e. accuracy and precision) which is determined by their intended use and should be comparable with other analytical measurements produced elsewhere. In order to enable laboratories in Member States to generate analytical measurements with appropriate and internationally recognised quality the main objectives of AQCS programme are: to provide the analyst with tools to compare and evaluate their performance relative to other laboratories, to assess the accuracy and precision of the analytical method used, to provide objective evidence on the quality of the results, and to ensure comparable analytical results within projects and networks

  19. Adaptive quality control for multimedia communications

    Directory of Open Access Journals (Sweden)

    Santichai Chuaywong

    2008-01-01

    Full Text Available Multimedia communications are communications with several types of media, such as audio, video and data. The current Internet has some levels of capability to support multimedia communications, unfortunately, the QoS (Quality of Service is still challenging. A large number of QoS mechanisms has been proposed; however, the main concern is for low levels, e.g. layer 2 (Data Link or 3 (Transport. In this paper, mechanisms for control the quality of audio and video are proposed. G.723.1 and MPEG-4 are used as the audio and video codec respectively. The proposed algorithm for adaptive quality control of audio communication is based on forward error correction (FEC. In the case of video communication, the proposed algorithm adapts the value of key frame interval, which is an encoding parameter of MPEG-4. We evaluated our proposed algorithms by computer simulation. We have shown that, in most cases, the proposed scheme gained a higher throughput compared to other schemes.

  20. Optimization and quality control of computed radiography

    Science.gov (United States)

    Willis, Charles E.; Weiser, John C.; Leckie, Robert G.; Romlein, John R.; Norton, Gary S.

    1994-05-01

    Computed radiography (CR) is a relatively new technique for projection radiography. Few hospitals have CR devices in routine service and only a handful have more than one CR unit. As such, the clinical knowledge base does not yet exist to establish quality control (QC) procedures for CR devices. Without assurance that CR systems are operating within nominal limits, efforts to optimize CR performance are limited in value. A complete CR system includes detector plates that vary in response, cassettes, an electro-optical system for developing the image, computer algorithms for processing the raw image, and a hard copy output device. All of these subsystems are subject to variations in performance that can degrade image quality. Using CR manufacturer documentation, we have defined acceptance protocols for two different Fuji CR devices, the FCR 7000 and the AC1+, and have applied these tests to ten individual machines. We have begun to establish baseline performance measures and to determine measurement frequencies. CR QC is only one component of the overall quality control for totally digital radiology departments.

  1. Research for quality control in the SEM/SIMS analysis of uranium-containing particles

    International Nuclear Information System (INIS)

    Based on the quality-control methods applied to the analysis of uranium-containing particles by SIMS in IAEA nuclear safeguards analytical laboratory and combined with the practical conditions of laboratory, the quality-control methods for the SEM/SIMS analysis have been explored primarily. It is showed that cross-contamination is essential in the SEM/SIMS analysis. Fume hood is the critical area of the introduction of cross-contamination during the process of sample preparation and handling. The chamber of SEM is the key area of the introduction of cross-contamination in the process of analysis. The list of contamination and the corresponding measures have been established. In the research of quality-control samples, the room blanks, process blank, standard samples and blind samples were analyzed. The initial quality-control methods for the SEM/SIMS analysis have been built up. It is demonstrated that the study of quality control is effective through the analysis of swipe samples. An important progress has been made in contamination control and analysis control, which provides the support for the establishment of a sound quality-assurance system in our laboratory. (authors)

  2. Quality control in the year 2000.

    Science.gov (United States)

    Schade, B

    1992-01-01

    'Just-in-time' production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and problem-solving will be easier. To achieve just-in-time release, advanced automated systems like robots will become the workhorses in QC for high volume pharmaceutical production. The requirements for these systems are extremely high in terms of quality, reliability and ruggedness. Crucial for the success might be advances in use of microelectronics for error checks, system recording, trouble shooting, etc. as well as creative new approaches (for example the use of redundant assay systems). PMID:18924930

  3. Progress in quality control of alanine dosimeters

    International Nuclear Information System (INIS)

    The ESR/alanine system has been used for different applications, over several years, as a classical routine dosimetry service. This service is based on alanine dosimeters constituted by pellets manufactured by our laboratory, which are presented with some specifications of use and different parameters bound to the intrinsic quality of the dosimeter itself. These parameters were obtained through the strict application of a production protocol and a validation protocol created, tested and validated under a quality assurance system. Every year, one batch of photon dosimeters is produced and controlled using these protocols and the specifications associated with it are checked. Two categories of data are considered separately: physical parameters and experimental data obtained by measurement on our ESR system are given with their associated standard deviation. (author)

  4. Microbiological quality control practices at Australian Radioisotopes

    International Nuclear Information System (INIS)

    As a domestic manufacturer of therapeutic substances, Australian Radioisotopes (ARI) must adhere to guidelines set out by the Commonwealth Department of Health in the Code of Good Manufacturing Practices for Therapeutic Goods 1983 (GMP). The GMP gives guidelines for staff training, building requirements, sanitation, documentation and quality control practices. These guidelines form the basis for regular audits performed by officers of the National Biological Standards Laboratories. At Lucas Heights, ARI has combined the principles of the GMP with the overriding precautions introduced for environmental and staff safety and protection. Its policy is to maintain a high level of quality assurance for product identity, purity and sterility and apyrogenicity during all stages of product manufacture

  5. Radar data quality control methods in VOLTAIRE

    Energy Technology Data Exchange (ETDEWEB)

    Golz, C.; Einfalt, T. [einfalt und hydrotec GbR, Luebeck (Germany); Galli, G. [MeteoSvizzera, Locarno-Monti (Switzerland)

    2006-10-15

    In the scope of the EU-project VOLTAIRE (Validation of multisensors precipitation fields and numerical modelling in Mediterranean test sites) a software library for automatic and rapid radar data quality check and modification has been developed and tests have been performed with data from different countries. Automatic procedures will never replace an experienced observer, but they help him to do his work and they can be used at places, where observation is not possible.This paper gives an overview over the algorithms that have been adopted or developed during the VOLTAIRE project for radar data quality control. Two examples of these algorithms illustrate the possibilities for data correction but also their limitations. These examples are a clutter correction combined with speckle removal for plan position indicator (PPI) data in particular of non-Doppler radars and a beam blockage correction for PPI data, where no digital elevation model (DEM) is available. (orig.)

  6. spark chamber

    CERN Multimedia

    A few cosmic rays pass through your body every second of every day, no matter where you are. Look at the spark chamber to your right – every flash is the track made by a cosmic ray from outer space. The spark chamber is filled with a special gas mixture. Cosmic rays knock electrons out of the atoms in the gas. These electrons accelerate towards high voltage metal strips layered throughout the chamber, creating sparks like little bolts of lightning.

  7. spark chamber

    CERN Multimedia

    A few cosmic rays pass through your body every second of every day, no matter where you are. Look at the spark chamber to your right – every flash is the track made by a cosmic ray from outer space. The spark chamber is filled with a special gas mixture. Cosmic rays knock electrons out of the atoms in the gas. These electrons accelerate towards high voltage metal strips layered throughout the chamber, creating sparks like little bolts of lightning.

  8. Radiated Emissions from a Remote-Controlled Airplane-Measured in a Reverberation Chamber

    Science.gov (United States)

    Ely, Jay J.; Koppen, Sandra V.; Nguyen, Truong X.; Dudley, Kenneth L.; Szatkowski, George N.; Quach, Cuong C.; Vazquez, Sixto L.; Mielnik, John J.; Hogge, Edward F.; Hill, Boyd L.; Strom, Thomas H.

    2011-01-01

    A full-vehicle, subscale all-electric model airplane was tested for radiated emissions, using a reverberation chamber. The mission of the NASA model airplane is to test in-flight airframe damage diagnosis and battery prognosis algorithms, and provide experimental data for other aviation safety research. Subscale model airplanes are economical experimental tools, but assembling their systems from hobbyist and low-cost components may lead to unforseen electromagnetic compatibility problems. This report provides a guide for accommodating the on-board radio systems, so that all model airplane systems may be operated during radiated emission testing. Radiated emission data are provided for on-board systems being operated separately and together, so that potential interferors can be isolated and mitigated. The report concludes with recommendations for EMI/EMC best practices for subscale model airplanes and airships used for research.

  9. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  10. Quality control of krypton-81m generator

    Energy Technology Data Exchange (ETDEWEB)

    Comet, M.; Croize, J.; Gaudy, M.; Mathieu, J.P.; Pernin, C.; Dubois, F.; Verain, A. (C.H.R.U., Grenoble (France)); Godart, J.; Boutet, J. (Institut des Sciences Nucleaires, Grenoble (France))

    1982-01-01

    The control of quality of the short half life radiopharmaceutical krypton-81m in solution is detailed. Because it is not possible to test sterility, to measure the pH and the activity of the contaminants and to search pyrogen in the solution which will be injected, a compromise must be done. If the characteristics of the eluat of the generator (pH, activity of the contaminants) are stable and in acceptable limits during 3 hours, the perfusion must be done with an acceptable risk. The apyrogenicity of the eluat must be tested with the rabbit pyrogen test and with the L.A.L. before injection. The control of sterility must be done though the results are obtained long after the perfusion.

  11. Quality control of krypton-81m generator

    International Nuclear Information System (INIS)

    The control of quality of the short half life radiopharmaceutical krypton-81m in solution is detailed. Because it is not possible to test sterility, to measure the pH and the activity of the contaminants and to search pyrogen in the solution which will be injected, a compromise must be done. If the characteristics of the eluat of the generator (pH, activity of the contaminants) are stable and in acceptable limits during 3 hours, the perfusion must be done with an acceptable risk. The apyrogenicity of the eluat must be tested with the rabbit pyrogen test and with the L.A.L. before injection. The control of sterility must be done though the results are obtained long after the perfusion

  12. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by...

  13. Indoor air quality control; Sisaeilman laadun hallinta

    Energy Technology Data Exchange (ETDEWEB)

    Villberg, K.; Saarela, K.; Tirkkonen, T. [VTT Building and Transport, Espoo (FI)] [and others

    2004-06-01

    Indoor Air Quality Control-project (Dno 188/401/00, 40724/00), one part of the Finnish Research Programme on Environmental Health (SYTTY), was consisted of three parts. In part one the objective was to establish a causal connection between indoor air quality, perceived comfort and diagnosed health effects. The indoor air quality was measured with methods used today in the Finnish classification, but complementary new methods were applied and tested for their relevance in attaining a better coverage of different chemical substances in indoor air. The health and comprehensive indoor air data were collected from subjects, which were chosen among the patients treated in Helsinki University Central Hospital because of building related symptoms. Additionally control families were randomly selected from Helsinki area. All participants were interviewed for their residential conditions and any building related problems using modified Oerebro and Tuohilampi questionnaires. Clinical data was only collected from the patients in medical examination. All these data was used as additional information in drafting conclusions and recommendations for the improvement of characterising indoor air quality and the classification procedure. In the second part the aim was to develop procedures to evaluate the irritating and odorous chemical compounds of material emissions and the perceived air quality. The causative relationships between sensory assessment method used in the present Finnish Classification of Building Materials, olfactometry and emission measurements in chemical terms were determined. Another objective of this project was to investigate irritation properties of building material emissions and chemical mixtures by the mouse bioassay. In addition the indicator value of human evaluation was clarified for estimating irritancy of building material emission and for studying an impact of ageing of materials on odour and irritation responses. Finally a model was developed for

  14. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are increa

  15. Quality Control, Quality Assurance, and Quality Improvement-What is the Difference and Why Should Compounding Pharmacies Care?

    Science.gov (United States)

    Cabaleiro, Joe

    2009-01-01

    This article provides scenarios of three different pharmacies in the areas of quality control, quality assurance, and quality improvement. The scenarios show the importance that each pharmacy placed on a problem of dented capsules and the potential impact that an unresolved problem can have on a compounding pharmacy's business. Although this article focuses on one particular procedure, the purpose of th article is to help pharmacists understand the differences between quality control, quality assurance, and quality improvement. PMID:23966522

  16. Quality control of radioimmunoassay for proteins

    International Nuclear Information System (INIS)

    The philosophy and achievements of the first two and a half years of a national quality control scheme for serum growth hormone assays are described. Three serum samples were distributed to participating laboratories every two weeks. A computer-produced summary of the quality control results, containing scattergrams and statistical analysis, was returned to participants. The performance of 11 experienced (SAS) laboratories was found to fulfil the necessary accuracy criteria, thus providing the 'reference group mean', and target value. Gross positive bias exhibited by several laboratories was due to the use of assays with inadequate sensitivity, and was promptly eliminated. During the course of the Scheme the average bias fell from 30 to 14%. With assays of adequate sensitivity, bias was almost invariably due to the misuse of standards. Median within-laboratory, between-batch precision (CV) improved from 23 to 15%. The best performers achieved between-batch CV of 7% which was 1.5 x their within-batch CV: the worst had three-to four-fold differences between within- and between-batch CV. A 'recommended procedure' based upon supplied first and second antibody, and a communal 'reference range' from 280 untreated acromegalics, both proved valuable. (author)

  17. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  18. Growth of optical-quality anthracene crystals doped with dibenzoterrylene for controlled single photon production

    Energy Technology Data Exchange (ETDEWEB)

    Major, Kyle D., E-mail: kyle.major11@imperial.ac.uk; Lien, Yu-Hung; Polisseni, Claudio; Grandi, Samuele; Kho, Kiang Wei; Clark, Alex S.; Hwang, J.; Hinds, E. A., E-mail: ed.hinds@imperial.ac.uk [Centre for Cold Matter, Department of Physics, Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    Dibenzoterrylene (DBT) molecules within a crystalline anthracene matrix show promise as quantum emitters for controlled, single photon production. We present the design and construction of a chamber in which we reproducibly grow doped anthracene crystals of optical quality that are several mm across and a few μm thick. We demonstrate control of the DBT concentration over the range 6–300 parts per trillion and show that these DBT molecules are stable single-photon emitters. We interpret our data with a simple model that provides some information on the vapour pressure of DBT.

  19. Growth of optical-quality anthracene crystals doped with dibenzoterrylene for controlled single photon production

    International Nuclear Information System (INIS)

    Dibenzoterrylene (DBT) molecules within a crystalline anthracene matrix show promise as quantum emitters for controlled, single photon production. We present the design and construction of a chamber in which we reproducibly grow doped anthracene crystals of optical quality that are several mm across and a few μm thick. We demonstrate control of the DBT concentration over the range 6–300 parts per trillion and show that these DBT molecules are stable single-photon emitters. We interpret our data with a simple model that provides some information on the vapour pressure of DBT

  20. Quality assurance and quality control in fabrication of cladding tubes

    International Nuclear Information System (INIS)

    Zircaloy 2 and 4 are the most important Zirconium alloys for use as fuel cladding material in light and heavy water reactors. In fast breeder reactors the cladding tubes are of a modified 16/16 - Cr-Ni-type with improved mechanical, long - term creep rate and rupture - life versus temperature properties. Starting with hot-extruded tube shells the fabrication of Zircaloy cladding tubes is done by 3 - 4 cold reduction steps in tube reducers or rolling machines followed by heat treatments in vacuum. To obtain the specified properties a precise combination of final area reduction and final annealing is absolutely necessary. The fabrication route of stainless steel claddings and guide tubes is similar to the Zircaloy production, exceptionally the last cold-forming steps are made on cold-drawing henches, hecause of economic reasons. After each cold reduction the material is annealed at recrystalisation temperatures under protective atmosoheres. For obtaining the same final tube properties for a longer nroduction neriod the implementation of a quality assurance and control system naturally independent of the production is necessary. The application of this system regarding some of the important properties of fuel cladding tubes is reported. (RW)

  1. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable...

  2. 21 CFR 864.8625 - Hematology quality control mixture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality control mixture. (a) Identification. A hematology quality control mixture is a device used...

  3. 7 CFR 275.21 - Quality control review reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 4 2010-01-01 2010-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the...

  4. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner...

  5. Quality control for electronic portal imaging devices

    International Nuclear Information System (INIS)

    Full text: The need for objective quality control of electronic portal imaging devices (EPIDs) arises at a number of different stages. The manufacturer should be able to conduct a test before shipping the EPID, to be sure that the device meets predetermined specifications. On installation, the engineer should have a simple and definitive test to ensure that installation is complete. The customer also requires proof that specifications have been met. And a quick and easy test is required for daily or weekly verification that the EPID is operating as well as at installation. All the suppliers of EPIDs provide copies of the 'Las Vegas' phantom, but this is a highly subjective test that was never intended to be used for routine quality control. A quality control test is described which involves acquiring a pair of portal images of a specially designed phantom, followed by totally automatic analysis to provide quantities related to the spatial resolution and the contrast-to-noise ratio. The phantom includes five bar patterns, with spatial frequencies from 0.1 to 0.75 1p/mm. The measured modulation in each pattern is normalized to the value at the lowest frequency, and the spatial frequency f50 corresponding to a 50% decrease in RMIF is used as the measure of spatial resolution. Contrast is measured in regions of the phantom with different attenuations, and noise is obtained from the difference image derived from the original pair. Tests were conducted on EPIDs from all the commercial suppliers. By determining f50 with the phantom placed on the surface of the EPID, and again at isocenter (ISO), it is possible to determine the relative contributions to image blurring from the EPID (E) and from the effect of the finite focal spot size in the linac (S). In all cases the effect of the focal spot is dominant. The results are presented in a table, which shows mean values of the resolution, blurring parameters E and S, the optimal magnification, and the best attainable

  6. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  7. Quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  8. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  9. Quality control of secondary standards and calibration systems, therapy level, of National Laboratory of Metrology from Ionizing Radiations (LNMRI)

    International Nuclear Information System (INIS)

    The results of quality control program of secondary standards, therapy level, and the calibration system of clinical dosemeters were analysed from 1984, when a change in the laboratory installation occurred and new standards were obtained. The national and the international intercomparisons were emphasised. The results for graphite wall chambers were compared, observing a maximum variation of about 0,6%. In the case of Delrin (TK01) wall chambers, the maximum variation was 1,7%. The results of post intercomparisons with thermoluminescent dosemeters have presented derivations lesser than 1%, securing the standards consistence at LNMRI with the international metrological system. (C.G.C.)

  10. Analytical quality control [An IAEA service

    International Nuclear Information System (INIS)

    In analytical chemistry the determination of small or trace amounts of elements or compounds in different types of materials is increasingly important. The results of these findings have a great influence on different fields of science, and on human life. Their reliability, precision and accuracy must, therefore, be checked by analytical quality control measures. The International Atomic Energy Agency (IAEA) set up an Analytical Quality Control Service (AQCS) in 1962 to assist laboratories in Member States in the assessment of their reliability in radionuclide analysis, and in other branches of applied analysis in which radionuclides may be used as analytical implements. For practical reasons, most analytical laboratories are not in a position to check accuracy internally, as frequently resources are available for only one method; standardized sample material, particularly in the case of trace analysis, is not available and can be prepared by the institutes themselves only in exceptional cases; intercomparisons are organized rather seldom and many important types of analysis are so far not covered. AQCS assistance is provided by the shipment to laboratories of standard reference materials containing known quantities of different trace elements or radionuclides, as well as by the organization of analytical intercomparisons in which the participating laboratories are provided with aliquots of homogenized material of unknown composition for analysis. In the latter case the laboratories report their data to the Agency's laboratory, which calculates averages and distributions of results and advises each laboratory of its performance relative to all the others. Throughout the years several dozens of intercomparisons have been organized and many thousands of samples provided. The service offered, as a consequence, has grown enormously. The programme for 1973 and 1974, which is currently being distributed to Member States, will contain 31 different types of materials

  11. The growing need for analytical quality control

    International Nuclear Information System (INIS)

    Technological development in a country is directly dependent upon its analytical chemistry or measurement capability, because it is impossible to achieve any level of technological sophistication without the ability to measure. Measurement capability is needed to determine both technological competence and technological consequence. But measurement itself is insufficient. There must be a standard or a reference for comparison. In the complicated world of chemistry the need for reference materials grows with successful technological development. The International Atomic Energy Agency has been distributing calibrated radioisotope solutions, standard reference materials and intercomparison materials since the early 1960's. The purpose of this activity has been to help laboratories in its Member States to assess and, if necessary, to improve the reliability of their analytical work. The value and continued need of this service has been demonstrated by the results of many intercomparisons which proved that without continuing analytical quality control activities, adequate reliability of analytical data could not be taken for granted. Analytical chemistry, lacking the glamour of other aspects of the physical sciences, has not attracted the attention it deserves, but in terms of practical importance, it warrants high priority in any developing technological scheme, because without it there is little chance to evaluate technological success or failure or opportunity to identify the reasons for success or failure. The scope and the size of the future programme of the IAEA in this field has been delineated by recommendations made by several Panels of Experts; all have agreed on the importance of this programme and made detailed recommendations in their areas of expertise. The Agency's resources are limited and it cannot on its own undertake the preparation and distribution of all the materials needed. It can, however, offer a focal point to bring together different

  12. Automatic control system for measuring currents produced by ionization chambers; Automatizacao de um sistema de medidas de correntes produzidas por camaras de ionizacao e aplicacao na calibracao do {sup 18}F e {sup 153}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Brancaccio, Franco

    2002-07-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for {sup 18}F and {sup 153}Sm were obtained, making possible to determine activities of these radionuclides. (author)

  13. Managerial Ability and Internal Control Quality: Evidence from China

    OpenAIRE

    2015-01-01

    Internal control quality of the firms can be determined by the firms¡¯ specific features, auditing quality and corporate governance. This research tries to make sure another factor-managerial ability is positively associated with internal control quality. With the evidences based on the A share in China¡¯s capital markets from 2009 to 2012, this research testifies that this relationship is statistically significant. Disclosing the internal control quality for all listed firms in China are man...

  14. Vacuum chamber

    International Nuclear Information System (INIS)

    A detailed description is given of the vacuum chamber of the so-called experimental equipment DEMAS (double-arm-time-of-flight spectrometer) at the heavy ion accelerator U-400 at the JINR-Dubna. (author)

  15. Development of a dose-controlled multiculture cell exposure chamber for efficient delivery of airborne and engineered nanoparticles

    International Nuclear Information System (INIS)

    In order to study the various health influencing parameters related to engineered nanoparticles as well as to soot emitted by Diesel engines, there is an urgent need for appropriate sampling devices and methods for cell exposure studies that simulate the respiratory system and facilitate associated biological and toxicological tests. The objective of the present work was the further advancement of a Multiculture Exposure Chamber (MEC) into a dose-controlled system for efficient delivery of nanoparticles to cells. It was validated with various types of nanoparticles (Diesel engine soot aggregates, engineered nanoparticles for various applications) and with state-of-the-art nanoparticle measurement instrumentation to assess the local deposition of nanoparticles on the cell cultures. The dose of nanoparticles to which cell cultures are being exposed was evaluated in the normal operation of the in vitro cell culture exposure chamber based on measurements of the size specific nanoparticle collection efficiency of a cell free device. The average efficiency in delivering nanoparticles in the MEC was approximately 82%. The nanoparticle deposition was demonstrated by Transmission Electron Microscopy (TEM). Analysis and design of the MEC employs Computational Fluid Dynamics (CFD) and true to geometry representations of nanoparticles with the aim to assess the uniformity of nanoparticle deposition among the culture wells. Final testing of the dose-controlled cell exposure system was performed by exposing A549 lung cell cultures to fluorescently labeled nanoparticles. Delivery of aerosolized nanoparticles was demonstrated by visualization of the nanoparticle fluorescence in the cell cultures following exposure. Also monitored was the potential of the aerosolized nanoparticles to generate reactive oxygen species (ROS) (e.g. free radicals and peroxides generation), thus expressing the oxidative stress of the cells which can cause extensive cellular damage or damage on DNA.

  16. Indoor air quality: sources and control

    International Nuclear Information System (INIS)

    The nature of the indoor air quality problem is described; methods of control or reduction of indoor radon and radon progeny concentrations have been reviewed. These techniques may be categorized as radon source reduction, radon removal, and radon progeny removal. There are a number of potential sources of radon in US housing, including soil, potable water, and building materials. In most cases, it appears that flow of radon-bearing soil gas into houses, driven by a slight negative pressure differential across the building shell, is a major source of indoor radon; this pressure-driven flow appears to be the most likely source of radon that can account for the elevated radon concentrations observed in some houses. There are a number of radon source control techniques; their effectiveness will depend upon characteristics of the house substructure and the details of the specific application. While the results of such remedial measures have varied and the data base from which to generalize is small, five-to-ten-fold reductions in radon concentration have been reported. 31 references, 4 figures

  17. Quality control of antibodies for assay development.

    Science.gov (United States)

    Schumacher, Sarah; Seitz, Harald

    2016-09-25

    Antibodies are used as powerful tools in basic research, for example, in biomarker identification, and in various forms for diagnostics, for example, identification of allergies or autoimmune diseases. Due to their robustness and ease of handling, immunoassays are favourite methods for investigation of various biological or medical questions. Nevertheless in many cases, additional analyses such as mass spectrometry are used to validate or confirm the results of immunoassays. To minimize the workload and to increase confidence in immunoassays, there are urgent needs for antibodies which are both highly specific and well validated. Unfortunately many commercially available antibodies are neither well characterized nor fully tested for cross-reactivities. Adequate quality control and validation of an antibody is time-consuming and can be frustrating. Such validation needs to be performed for every assay/application. However, where an antibody validation is successful, a highly specific and stable reagent will be on hand. This article describes the validation processes of antibodies, including some often neglected factors, as well as unspecific binding to other sample compounds in a multiparameter diagnostic assay. The validation consists of different immunological methods, with important assay controls, and is performed in relation to the development of a diagnostic test. PMID:26873787

  18. Requirements for quality control of analytical data

    International Nuclear Information System (INIS)

    The National Contingency Plan (NCP) of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) provides procedures for the identification, evaluation, and remediation of past hazardous waste disposal sites. The Hazardous Materials Response section of the NCP consists of several phases: Preliminary Assessment, Site Inspection, Remedial Investigation, Feasibility Study, Remedial Design, and Remedial Action. During any of these phases, analysis of soil, water, and waste samples may be performed. The Hazardous Waste Remedial Actions Program (HAZWRAP) is involved in performing field investigations and sample analyses pursuant to the NCP for the US Department of Energy and other federal agencies. The purpose of this document is to specify the requirements of Martin Marietta Energy Systems, Inc., for the control of accuracy, precision, and completeness of samples and data from the point of collection through analysis. Requirements include data reduction and reporting of resulting environmentally related data. Because every instance and concern may not be addressed in this document, HAZWRAP subcontractors are encouraged to discuss any questions with the Analytical Quality Control Specialist (AQCS) and the HAZWRAP Project Manager. This revision supercedes all other versions of this document

  19. Development of a vacuum control system for plasma welding chamber%等离子焊箱真空控制系统研制

    Institute of Scientific and Technical Information of China (English)

    张乃禄; 李洋; 许道玉; 李选锋; 刘中磊

    2012-01-01

    在钛及钛合金熔炼生产中,真空等离子焊接是电极制备的重要工序,而真空等离子焊接的真空度对铸锭的质量影响很大.针对真空等离子焊箱真空控制系统的工艺和控制要求,研制基于工控机+PLC(S7-300) +INFICON PCG410-S真空计的集散控制系统,实现了对真空泵组、电磁阀、真空压力和枪抽空进行实时监测与控制优化.生产实际应用表明,该系统在提高抽真空效率,降低漏率,确保高质量钛及钛合金电极生产方面效果显著,具有一定的应用前景.%In smelting titanium and its alloy, vacuum plasma welding is an important process for electrode preparation, and the vacuum degree influences the ingot quality greatly. According to the requirements of technology and control system of vacuum plasma welding chamber, the distributed control system was built based on IPC, PLC ( S7-300 ) and INFICON PCG410-S vacuum gauge, which realized real-time monitoring and control optimization of the vacuum pump, electromagnetic valve, vacuum pressure and vacuum-pumping of gun. The practical application indicates that the system play a good role in improving the efficiency of vacuum pumping, reducing the leakage rate, and ensuring the production of high quality of titanium and titanium alloy electrodes, which has certain application prospects.

  20. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control...

  1. Probing microelectromechanical systems in an environmentally controlled chamber using long working distance interferometry.

    Science.gov (United States)

    Soylemez, E; Plass, R A; Ashurst, W R; de Boer, M P

    2013-07-01

    It is well known that the environment in which micromechanical systems operate significantly affects their performance. It is, therefore, important to characterize micromachine behavior in environments where the humidity, pressure, and chemical composition of the ambient can be precisely controlled. Achieving such a level of environmental control presents significant challenges in view of the required instrumentation. To that end, a custom micromachine characterization system is built that allows for full environmental control (pressure, humidity, and gas composition) while retaining full micromachine characterization techniques (long working distance interferometry, electrical probe connectivity, actuation scripting capability). The system also includes an effective in situ surface cleaning mechanism. As an example of the system's utility, a microcantilever crack healing experiment is conducted and surface adhesion energy measurements are tracked over time after a step change in humidity is applied. PMID:23902098

  2. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy

  3. Predicting methyl iodide emission, soil concentration, and pest control in a two-dimensional chamber system

    Science.gov (United States)

    Due to ever increasing state and federal regulations, the future use of fumigants is predicted on negative environmental impacts while offering sufficient pest control efficacy. To foster the development of the best management practice (BMP), an integrated tool is needed to simultaneously predict fu...

  4. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  5. Quality control for overcoring stress measurement data

    International Nuclear Information System (INIS)

    The in situ state of stress is one of the key rock mechanical factors considering the safety and stability of underground excavations for civil and mining engineering purposes in greater depth, but at the same time measuring and interpretation of stress comes more difficult. Normally the in situ stress interpretation is based on final strain readings and there have not been practical and objective tools to judge transient strain behaviour during overcoring. This study was set up by nuclear waste management companies Posiva Oy (Finland) and Svensk Kaernbraenslehantering AB (Sweden) to improve the quality of interpretation of overcoring stress measurement results. The primary product of the project is quality control capability of overcoring stress measurement data. For this purpose a computer program was developed which can simulate the transient strains and stresses during the overcoring in any in situ stress and coring load conditions. The solution is based on superpositioning of elastic stresses and the basic idea can be applied also for different overcoring probes with minor modifications and recalculation of stress tensors. The measured strains can be compared to calculated ones to check if the measured transient behaviour is accordant with interpreted in situ state of stress. If not, the in situ state of stress can be calculated based any transient or final strain values. The transient stresses can be compared to strength envelope of intact rock and thereby estimate core damage potential. Technically the developed OCS-code fulfilled all the objectives and the numerical error was found to be less than 5%. The analysed case studies showed clearly the advance of having objective method study the reliability of stress measurement data. On the other hand, the interpretation of in situ state of stress from on early strains is difficult because the solution is very sensitive for measured strains and coring advance. The report also includes a comprehensive list of

  6. Production and quality control of 166 Ho

    International Nuclear Information System (INIS)

    Full text: Radioisotope production is one of the most important sectors in the mid and long term program of nuclear technology development. Therapeutic radiopharmaceuticals allow nuclear physicians to treat disease by attacking only the affected cells. The advantage of nuclear therapeutic over other therapies is that nuclear therapy can eliminate cancerous cells almost without harming healthy cells. Nuclear therapy would greatly improve quality of live by lowering the overall cost of the hospital, and reducing the time a patient stays in the hospital, and reducing the pain and suffering experienced by the patient. Several new radionuclides and carriers have recently been studied for treatment of various joint disorders. Ho-166 is a radionuclide with excellent physical properties for therapeutic application. Holmium-166 is produced by neutron capture on 100% abundant, stable holmium-165 with thermal neutron and resonance neutron cross section of 61.2 barns, respectively. It decays with 26.83 h half-life by emission of 1.855 MeV(51%) and 1.776 MeV (48%). Ho-166 also emits 80.5 keV gamma-ray in 6.2% abundance and, thus, is imageable by conventional techniques. Holmium-166 is utilized in radiotherapeutic applications such as radioimunospecific pharmaceuticals, bone marrow ablation, and radiation synovectomy. The radionuclide 166Ho is successfully produced by 165Ho (n,γ)166Ho reaction in the Nuclear Research Reactor (5 MW) at the neutron flux density 5*1013 n.cm-2.s-1. This study was focused to the preparation and quality control (especially of the radiochemical and radionuclide control) of the 166Ho. References: 1. Han .H .S, et al.: Current status and future plan for the production of radioisotopes using HANARO Research Reactor: journal of radioanalytical and Nuclear Chemistry, vol. 257, No.1 (2003) 47-51.; 2. Kyug Bae Park, Production Ho-166, IAEA-TECDOC-1340, IAEA: 71-74, 2003.; 3. Heuft-Dorenbusch L., et al.: Yttrium radiosynovectomy in the treatment of knee

  7. Vacuum and gas flow control system for a MWPC and an axial chamber

    International Nuclear Information System (INIS)

    An automatic system that controls the vacuum, gas flow and pressure regulation operations has been constructed for two gas-filled detectors operating in series. To keep constant the amount of the gas in the detectors the pressure values are adjusted as a function of the temperature. The system is based on a CPU (Motorola 68000) in a VME bus. The performances of this system have been tested with satisfactory results

  8. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  9. Crop quality control system : a tool to control the visual quality of pot plants

    OpenAIRE

    Dijkshoorn-Dekker, M.W.C.

    2002-01-01

    Key words: quality, growth, model, leaf unfolding rate, internode, plant height, plant width, leaf area, temperature, plant spacing, season, light, development, image processing, grading, neural network, pot plant, Ficus benjamina 'Exotica'.The market is increasingly dictating the specifications for products. A well-defined marketable product must be delivered at a defined moment in time. A system was developed for growers to control development and growth of pot plants to achieve a defined q...

  10. Quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  11. Quality assurance standards for purchasing and inventory control.

    Science.gov (United States)

    Soares, D P

    1985-03-01

    A process is described for quality assurance in pharmaceutical purchasing and inventory control. A quality assurance program should ensure that quality drugs are purchased at the lowest price, drug products are available when needed, the system is managed efficiently, internal controls are provided, drug products are stored under appropriate conditions, and laws, regulations, accreditation standards, and procedures are followed. To meet these objectives, product quality, vendor performance, the department's system of internal controls, purchasing data, and storage conditions should be monitored. A checklist for evaluating purchasing and inventory practices and a sample audit form listing quality assurance criteria, standards, procedures, and recommended actions are provided. A quality assurance program for pharmaceutical purchasing and inventory control should define institution-specific criteria and standards and use these standards for continual evaluation of all aspects of the purchasing and inventory control system. Documentation of quality assurance activities should be provided for use by the purchasing department, hospital administration, and regulatory bodies. PMID:3985026

  12. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  13. Toward standardising gamma camera quality control procedures

    Science.gov (United States)

    Alkhorayef, M. A.; Alnaaimi, M. A.; Alduaij, M. A.; Mohamed, M. O.; Ibahim, S. Y.; Alkandari, F. A.; Bradley, D. A.

    2015-11-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services.

  14. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  15. SALE, Quality Control of Analytical Chemical Measurements

    International Nuclear Information System (INIS)

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  16. Quality control and reliability of reported doses

    International Nuclear Information System (INIS)

    Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the evaluation or data management system, damage of the dosemeter itself or by the loss of dosemeter. In this article, an attempt is made to estimate the importance of the above-mentioned conditions. This is achieved by sending questionnaires to about 200 approved dosimetric services in Europe. In total 88 questionnaires were returned and analysed. In the questionnaires, the frequency of occurrence of the various error conditions were investigated. Participants were also asked to evaluate the impact of the error condition from a dosimetric point of view and what countermeasures are taken. The article summarises all responses and compares different sources of errors according to their impact on the uncertainty of the resulting dose and gives a comprehensive overview on quality control actions and reliability on reported doses from European dosimetric services. (authors)

  17. The quality control theory of aging

    Directory of Open Access Journals (Sweden)

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  18. IAEA quality control exercises on bioindicators

    International Nuclear Information System (INIS)

    Biomonitoring air pollution using plants became an official part of the IAEA projects in 1997. In 1998 the section of Nutritional and Health Related Environmental Studies (NAHRES) organized a quality control exercise on two bioindicators (NAT-5 exercise), comprising two lichen samples. The first lichen was collected at an industrial polluted area in Austria, and the second was reference material IAEA-336, obtained from an unpolluted region in Portugal. 15 laboratories from 15 Member States participated in the NAT-5 exercise, providing 17 sets of results. The following analytical methods were used to obtain values: neutron activation analysis (NAA), inductive coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), atomic absorption spectrometry (AAS), and particle induced X ray emission analysis (PIXE). 308 laboratory mean values for 47 elements were reported for the IAEA-336 lichen sample. More than 4 independent laboratory mean values were obtained for 26 elements and these were statistically evaluated. Only about 5% of the results were detected as outliers by the statistical tools. After statistical evaluation, the values were subjected to an assessment according to the recommended procedures for proficiency testing by interlaboratory comparisons (Draft ISO 13528). Reference values for 18 elements were available from the reference sheet of the material IAEA-336. The results presented illustrate the performance of the laboratories and show some discrepancy between non-destructive and destructive analytical techniques with elements of environmental interest. (author)

  19. MITOCHONDRIA QUALITY CONTROL AND MUSCLE MASS MAINTENANCE

    Directory of Open Access Journals (Sweden)

    Vanina eRomanello

    2016-01-01

    Full Text Available Loss of muscle mass and force occurs in many diseases such as disuse/inactivity, diabetes, cancer, renal and cardiac failure and in aging-sarcopenia. In these catabolic conditions the mitochondrial content, morphology and function are greatly affected. The changes of mitochondrial network influence the production of reactive oxygen species (ROS that play an important role in muscle function. Moreover, dysfunctional mitochondria trigger catabolic signaling pathways which feed-forward to the nucleus to promote the activation of muscle atrophy. Exercise, on the other hand, improves mitochondrial function by activating mitochondrial biogenesis and mitophagy, possibly playing an important part in the beneficial effects of physical activity in several diseases. Optimised mitochondrial function is strictly maintained by the coordinated activation of different mitochondrial quality control pathways. In this review we outline the current knowledge linking mitochondria-dependent signaling pathways to muscle homeostasis in aging and disease and the resulting implications for the development of novel therapeutic approaches to prevent muscle loss.

  20. Quality control in medical radiology using T.L.D

    International Nuclear Information System (INIS)

    In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO4:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 μGy and 0.35 μGy. The T.L.D. have revealed useful for the measures if the response to the dose is previously known for each set of beam parameters used for the irradiations. Otherwise, the tests with the dosimeters can serve to evaluate the beams conditions and their reproducibility. The evaluation results of coherence between the luminous fields and the irradiation fields demonstrated that the difference between the radiation and the luminous fields did not exceed 2% of the distance between the focal point and the film. We found satisfactory values for half-value layer. (author)

  1. Quality control in medical radiology using T.L.D

    Energy Technology Data Exchange (ETDEWEB)

    Rolemberg Silva, F.A.; Nascimento Souza, D. do [Universidade Federal de Sergipe - CCET - Dept. de Fisica, Sao Cristovao, SE (Brazil)

    2006-07-01

    In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 {mu}Gy and 0.35 {mu}Gy. The T.L.D. have revealed useful for the measures if the response to the dose is previously known for each set of beam parameters used for the irradiations. Otherwise, the tests with the dosimeters can serve to evaluate the beams conditions and their reproducibility. The evaluation results of coherence between the luminous fields and the irradiation fields demonstrated that the difference between the radiation and the luminous fields did not exceed 2% of the distance between the focal point and the film. We found satisfactory values for half-value layer. (author)

  2. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  4. Construction of the inner layer barrel drift chambers of the ATLAS muon spectrometer at the LHC

    International Nuclear Information System (INIS)

    We have designed and built the facilities to assemble the inner layer of the precision tracking chambers (Monitored Drift Tubes, MDT) for the Muon Spectrometer of the ATLAS Experiment at LHC. This article describes in detail the tooling, the procedures and the quality control equipment used in the chambers assembly. Data are presented from the X-ray tomograph at CERN showing that the required chamber mechanical precision has been achieved

  5. Performance of ionization chambers in X radiation beams, radioprotection level

    International Nuclear Information System (INIS)

    Narrow beams, radioprotection level, were implanted in an X ray system, based on ISO 4037-1, as recommended by IAEA (SRS 16). Energy dependency tests were carried out and short-term stability in ionization chambers for use in radiation protection of trademark Physikalisch-Technische Werkstaetten (PTW), 32002 and 23361 models. The ionization chambers were studied with regard to short-term stability within the program of quality control of the laboratory, with a 90Sr + 90Y. The results of the short-term stability test were compared with the recommendations of IEC 60731, respect to dosemeters used in radiotherapy, since this standard presents the more restrictive limits with regard to the behaviour of ionization chambers. All cameras showed results within the limits recommended by this standard. With respect to the energy dependency of the response, the model Chamber 32002 presented a maximum dependence of only 2.7%, and the model Chamber 23361, 4.5%

  6. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in...

  7. Quality-Driven Synthesis and Optimization of Embedded Control Systems

    OpenAIRE

    Samii, Soheil

    2011-01-01

    This thesis addresses several synthesis and optimization issues for embedded control systems. Examples of such systems are automotive and avionics systems in which physical processes are controlled by embedded computers through sensor and actuator interfaces. The execution of multiple control applications, spanning several computation and communication components, leads to a complex temporal behavior that affects control quality. The relationship between system timing and control quality is a...

  8. Auditor independence, audit committee quality and internal control weaknesses

    OpenAIRE

    Sorinel Domnișoru; Sorin-Sandu Vînătoru

    2008-01-01

    In this paper we investigate the relation between auditor independence, audit committee quality and the disclosure of internal control weaknesses. We begin with a sample of firms with internal control weaknesses and, based on industry, size, and performance, match these firms to a sample of control firms without internal control weaknesses. Our conditional logit analyses indicate that a relation exists between audit committee quality, auditor independence, and internal control weaknesses. Fir...

  9. Control of the heavy-ion beam line gas pressure and density in the HYLIFE thick-liquid chamber

    International Nuclear Information System (INIS)

    Controlling the density and pressure of the background gas in the beam lines of thick-liquid heavy-ion fusion chambers is of paramount importance for the beams to focus and propagate properly. Additionally, transport and deposition of debris material onto metal beam-tube surfaces may reduce the breakdown voltage and permit arcing with the beam. The strategy to control the gas pressure and the rate of debris deposition is twofold. First, the cool thick-liquid jet structures will mitigate the venting to the beam tubes. The ablation and venting of debris through thick-liquid structures must be modelled to predict the quantities of debris reaching the beam ports. TSUNAMI calculations have been performed to estimate the mass and energy flux histories at the entrance of the beam ports in a 9x9 HYLIFE pocket geometry. Secondly, additional renewable shielding will be interposed in the beam tubes themselves. Thick-liquid vortexes are planned to coat the inside of the beam tubes and provide a quasi-continuous protection of the beam-tube walls up to the final focus magnets. A three-component molten salt, flinabe, with a low melting temperature and vapor pressure, has been identified as a candidate liquid for the vortexes. The use of flinabe may actually eliminate the necessity of mechanical shutters to rapidly close the beam tubes after target ignition

  10. Application of an RF Biased Langmuir Probe to Etch Reactor Chamber Matching, Fault Detection and Process Control

    Science.gov (United States)

    Keil, Douglas; Booth, Jean-Paul; Benjamin, Neil; Thorgrimsson, Chris; Brooks, Mitchell; Nagai, Mikio; Albarede, Luc; Kim, Jung

    2008-10-01

    Semiconductor device manufacturing typically occurs in an environment of both increasing equipment costs and per unit sale price shrinkage. Profitability in such a conflicted economic environment depends critically on yield, throughput and cost-of-ownership. This has resulted in increasing interest in improved fault detection, process diagnosis, and advanced process control. Achieving advances in these areas requires an integrated understanding of the basic physical principles driving the processes of interest and the realities of commercial manufacturing. Following this trend, this work examines the usefulness of an RF-biased planar Langmuir probe^1. This method delivers precise real-time (10 Hz) measurements of ion flux and tail weighted electron temperature. However, it is also mechanically non-intrusive, reliable and insensitive to contamination and deposition on the probe. Since the measured parameters are closely related to physical processes occurring at the wafer-plasma interface, significant improvements in process control, chamber matching and fault detection are achieved. Examples illustrating the improvements possible will be given. ^1J.P. Booth, N. St. J. Braithwaite, A. Goodyear and P. Barroy, Rev.Sci.Inst., Vol.71, No.7, July 2000, pgs. 2722-2727.

  11. Quality assurance in food irradiation with emphasis on process control

    International Nuclear Information System (INIS)

    Process control is an essential component of quality assurance in food irradiation. This paper discusses the key elements of process control of gamma and electron beam irradiation of foods. They include irradiated product investigation and qualification, irradiator qualification (commissioning), dosimetry including calibration and dose-mapping, licensing documentation and inspection, and, details of routine process control. Radiation process control combined with incoming product quality control and outgoing (processed) product handling, etc., control constitute the essence of overall quality assurance in food irradiation. (author). 11 refs

  12. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Science.gov (United States)

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-01

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant1 software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC . PMID:26653327

  13. Robert Chambers

    NARCIS (Netherlands)

    K. Biekart (Kees); D.R. Gasper (Des)

    2013-01-01

    textabstractProfessor Robert Chambers is a Research Associate at the Institute of Development Studies (IDS), University of Sussex (Brighton, UK), where he has been based for the last 40 years, including as Professorial Research Fellow. He became involved in the field of development management in the

  14. Quality control by a mobile molecular workshop: quality versus quantity

    CERN Document Server

    Sharma, Ajeet K

    2010-01-01

    Ribosome is a molecular machine that moves on a mRNA track while, simultaneously, polymerizing a protein using the mRNA also as the corresponding template. We introduce quantitative measures of its performance which characterize, for example, the speed and fidelity of the template-dictated polymerization. We also define two different measures of efficiency and strength of mechano-chemical coupling of this molecular machine. We calculate all these quantities analytically. Some of these quantities show apparently counterintuitive trends of variation with the quality of kinetic proofreading. We interpret the origin of these trends. We suggest new experiments for testing some of the ideas presented here.

  15. Automated Electrostatics Environmental Chamber

    Science.gov (United States)

    Calle, Carlos; Lewis, Dean C.; Buchanan, Randy K.; Buchanan, Aubri

    2005-01-01

    The Mars Electrostatics Chamber (MEC) is an environmental chamber designed primarily to create atmospheric conditions like those at the surface of Mars to support experiments on electrostatic effects in the Martian environment. The chamber is equipped with a vacuum system, a cryogenic cooling system, an atmospheric-gas replenishing and analysis system, and a computerized control system that can be programmed by the user and that provides both automation and options for manual control. The control system can be set to maintain steady Mars-like conditions or to impose temperature and pressure variations of a Mars diurnal cycle at any given season and latitude. In addition, the MEC can be used in other areas of research because it can create steady or varying atmospheric conditions anywhere within the wide temperature, pressure, and composition ranges between the extremes of Mars-like and Earth-like conditions.

  16. Estimate of control rods effectiveness of the RP-0 reactor 7A2 core by the rod-drop method using a compensated ionization chamber

    International Nuclear Information System (INIS)

    Value estimate results of the four control rods by the rod-drop method are presented using the 'point reactor model' for the RP-0 reactor 7A2 core employing the inverse kinetics neutronic noise equipment and a compensated ionization chamber located in the E2 core. At every moment, the reactor power was known and it was calibrated with the same equipment

  17. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  18. Quality control and management of technegas generator

    International Nuclear Information System (INIS)

    Technegas generator is an important part of imaging devices of nuclear medicine department. Daily maintenance and management will be very helpful to ensure stability of instrument performance, reduce failure rate of instrument, ensure examination quality and reduce expenses. (authors)

  19. Experimental and numerical study of the active control of jets inside combustion chambers; Etude experimentale et numerique du controle actif de jets dans des chambres de combustion

    Energy Technology Data Exchange (ETDEWEB)

    Faivre, V.

    2003-12-15

    Combustion instabilities occur when the flame heat release couples with the acoustic waves propagating in the combustion chamber. This phenomenon can lead to strong vibrations and noise but also, sometimes, to the complete combustion device failure. That is the reason why so many studies focus on the control of those instabilities. The method chosen in this study consists in an active control device (or set of actuators) having a strong effect on the mixing of the burner exhaust flow with the ambient fluid. The model configuration studied consists in a non reactive jet of air controlled by four small tangential secondary jets. Experiments have been carried out to optimize the control device geometry. The configuration identified as the most efficient, in terms of mixing enhancement, has been simulated through Large Eddy Simulations (LES). The objective of the numerical part of the present work is double. First, the numerical simulations provide a better understanding of the phenomena occurring when the control is on. Then, it is shown that LES can be considered as a tool to predict the effects of a control device on a flow. (author)

  20. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  1. Joint Determination of Optimal Inventory and Quality Control Policy

    OpenAIRE

    Michael H. Peters; Helmut Schneider; Kwei Tang

    1988-01-01

    Typically the operating policy for the inventory control system for a commodity is developed independent of the operating policy for the quality control system for that commodity and vice versa. In many circumstances, these systems are dependent on one another. A cost model that combines a fixed order quantity inventory control system with a Bayesian quality control system for a lot-by-lot attribute acceptance sampling plan is presented along with an algorithm to obtain the operating paramete...

  2. Control of Bank Consolidated Financial Statements Quality

    OpenAIRE

    Margarita S. Ambarchyan

    2013-01-01

    The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the charact...

  3. Magnetotelluric quality control study and calibration survey

    International Nuclear Information System (INIS)

    We have performed a managetotelluric study in order to evaluate the data quality and reliability of magnetotelluric information obtained for Rockwell Hanford Operations by two sub-contractors. The motivation for performing this study resulted from: relatively poor and variable data quality and some major disagreements between the results obtained in these two surveys. Geotronics' task was to perform an analysis based on the material included in these survey reports and other available information

  4. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  5. Chemical and physical quality control of the HIPPURAN-131I

    International Nuclear Information System (INIS)

    Some physico-chemical methods for analytical control of Hippuran-131I are compared. The most convenient to applicate in hospitals and in more specialized quality control laboratories are recommended. The quality of Hippuran-131I produced by ISOTOP (USSR) is also evaluated. The product met the requirement of the International Pharmacopeia

  6. Importance of critical evaluation in quality control of scintillation cameras

    International Nuclear Information System (INIS)

    The evaluation of quality control results in nuclear medicine must be performed with a critical view over the conditions the tests are executed. This paper is a result of observations in the routine quality control where we set up didactic 'findings' to show the importance of evaluating critical situations while executing the procedures. (author)

  7. 75 FR 41874 - Quality Control for Rental Assistance Subsidy Determinations

    Science.gov (United States)

    2010-07-19

    ... URBAN DEVELOPMENT Quality Control for Rental Assistance Subsidy Determinations AGENCY: Office of the.... This notice also lists the following information: Title of Proposal: Quality Control for Rental... agency's estimate of the burden of the proposed collection of information; (3) Enhance the...

  8. Procedures for quality control of thermoluminescent dosimetry laboratory

    International Nuclear Information System (INIS)

    In order to assurance the results accuracy of a thermoluminescence dosimetry laboratory it is necessary a quality control program. For a laboratory in operation, without a structured program, the quality control should be started for documentation of its technical and administrative procedures. It is presented a proposal with the essential procedures to carry out this program. (author)

  9. Artificial Intelligence Approach to Support Statistical Quality Control Teaching

    Science.gov (United States)

    Reis, Marcelo Menezes; Paladini, Edson Pacheco; Khator, Suresh; Sommer, Willy Arno

    2006-01-01

    Statistical quality control--SQC (consisting of Statistical Process Control, Process Capability Studies, Acceptance Sampling and Design of Experiments) is a very important tool to obtain, maintain and improve the Quality level of goods and services produced by an organization. Despite its importance, and the fact that it is taught in technical and…

  10. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  11. Status and future trends of Analytical Quality Control Services

    International Nuclear Information System (INIS)

    This report reviews the present Analytical Quality Control Services (AQCS) programme components in the light of the needs of IAEA Member States for analytical reference materials and intercomparisons, provides guidelines for the direction which the programme should take in the future and identifies the type of Analytical Quality Control Services most urgently required by the Member States

  12. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G. D.

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  13. Ionization chamber

    International Nuclear Information System (INIS)

    An ionization chamber X-ray detector is described. It comprises a flat cathode sheet parallel to an anode which has a perforated insulating layer on its surface. An open grid, a thin perforated metal sheet is disposed on the insulating layer - the perforations of the layer and sheet are aligned. There is a detector gas and means for maintaining the grid at an electric potential between that of the anode and cathode and for measuring the current flow from the anode to the cathode. The grid shields the anode from the electric field produced by the positive ions which flow towards the cathode and this permits an independent measurement of the electron current flowing to the anode; even when the X-ray pulse length is not much shorter than the ion drift time. The recovery time of the ionization chamber is thus decreased by several orders of magnitude over previous chambers. The grid will normally be fixed to the anode and by shielding the anode from the cathode electric field, tends to eliminate capacitive microphone currents which would otherwise flow in the anode circuit. (U.K.)

  14. Monte Carlo Simulation in the Optimization of a Free-Air Ionization Chamber for Dosimetric Control in Medical Digital Radiography

    International Nuclear Information System (INIS)

    During the earliest tests of a free-air ionization chamber a poor response to the X-rays emitted by several sources was observed. Then, the Monte Carlo simulation of X-rays transport in matter was employed in order to evaluate chamber behavior as X-rays detector. The photons energy deposition dependence with depth and its integral value in all active volume were calculated. The obtained results reveal that the designed device geometry is feasible to be optimized

  15. French permanent survey on indoor air quality - Part 1.: Measurement protocols and quality control

    OpenAIRE

    Ramalho, Olivier; Derbez, Mickael; Gregoire, Anthony; Garrigue, Julien; Kirchner, Séverine

    2006-01-01

    This paper focuses on a synthesis of the measurement and analytical protocols from the 2003-2005 campaign of the French permanent survey on indoor air quality and presents the associated quality control system including data traceability, quality code and interlaboratory tests. Preliminary exploitation of measurement and analysis errors are presented

  16. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  17. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    OpenAIRE

    Hohaus, T.; Kuhn, U.; S. Andres; Kaminski, M.; Rohrer, F.; Tillmann, R.; A. Wahner; R. Wegener; Yu, Z.; Kiendler-Scharr, A.

    2015-01-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber ...

  18. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  19. Development of a diode dosimetric system for quality control of radiotherapy units

    International Nuclear Information System (INIS)

    A diode dosimetric system was developed and tested for quality control of photon and electron beams as used in radiotherapy. The following tests were done: repeatability and reproducibility, linearity, degradation with dose and response with the field size. These results were compared with the response of ionization chambers. For the most tests, the diode system presented similar response of it, which demonstrated its viability for clinical dosimetry use. A quality assurance program for a multi-beam accelerator was proposed as an example of its application in a routine use for a radiotherapy service. Besides its practicability of using, the system presents the advantage of low cost, compared to imported system in use nowadays. (author)

  20. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  1. Investigation of the applicability of a special parallel-plate ionization chamber for x-ray beam dosimetry

    Science.gov (United States)

    Perini, Ana P.; P. Neves, Lucio; E. Caldas, Linda V.

    2014-02-01

    Diagnostic x-rays are the greatest source of exposition to ionizing radiation of the population worldwide. In order to obtain accurate and lower-cost dosimeters for quality control assurance of medical x-ray facilities, a special ionization chamber was designed at the Calibration Laboratory of the IPEN, for dosimetry in diagnostic radiology beams. For the chamber characterization some tests were undertaken. Monte Carlo simulations were proposed to evaluate the distribution of the deposited energy in the sensitive volume of the ionization chamber and the collecting electrode effect on the chamber response. According to the obtained results, this special ionization chamber presents potential use for dosimetry of conventional diagnostic radiology beams.

  2. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  3. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  4. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  5. Methodical Grounds of Managing the Product Quality Control

    Directory of Open Access Journals (Sweden)

    Shapoval Olena A.

    2014-01-01

    Full Text Available The article analyses the modern state of products quality control management. It justifies a necessity of organisation of the quality control system under conditions of uninterrupted flow line production. It reveals problems connected with a low level of the products quality control management. It forms a set of factors of internal and external environments, which should be taken into account in the process of selection of a type of managerial actions by the products quality control. It considers specific features of identification of the most important factors at an enterprise on the basis of use of the matrix of strategic SWOT analysis. It offers a procedure of identification of a general assessment of factors of influence. It analyses a mechanism of use of main conceptual models, which reflect the system nature of quality management in an organisation – quality pyramids and quality loops. It proves a necessity of application of a principally new scheme of relations between the customer and enterprise, which envisages that requirements of the quality management system focus not on control and screening of semi-finished products, but on creation of conditions that exclude rejects. It considers the role of ISO 9000 in the system of quality management, which recommend the customers to make a preliminary assessment of activity of the producing enterprise.

  6. Quality control of virtual wedge in a linear electron accelerator with a computerized radiography system (CR); Control de calidad de la cuna virtual en un acelerador lineal de electrones mediante un sistema de radiografia competerizada (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Alvarez, F. J.; Falero, B.

    2011-07-01

    For quality control of the virtual wedge there are several systems on the market as arrays of detectors or ionization chambers, linear or 2D configuration, radiochromic films or digital imaging systems incorporated in electron linear accelerators (ALE ). The present work aims at implementing a system of Computed Radiography (CR) for a routine check of the virtual wedge.

  7. Justification and quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    The role of the radiodiagnostician in justification of x-ray examination is discussed. Under the final responsibility of the radio-diagnostician the more common examinations are performed by laboratory assistants. A justification judgement before by the radio-diagnostician does not take place. In case of complicated examinations often previous consultation between radio-diagnostician and clinician is necessary. The fast development of new techniques like CT, echography and MRI has as result that the modern radio-diagnostician develops more and more into a imaging-specialist. In the consultation with the clinician he advises about the optimal diagnostics for a certain patient, taking optimally into account the risks of x-radiation. The justifying role of the radio-diagnostician depends further upon the relation with the requiring physician. In general the inter-collegial consultation is assumed to be sufficient within the hospitals, however the feedback to general practitioners seems to be improvable in some cases. With regard to quality assurance it is remarked that the quality of the examination may not be endangered by a too strong emphasis upon radiation reduction. Aspects like education level, protocol learning, dose limits, degressive tariffs, information-transfer, radiation passport, analysis between 'blue' ton, centralization of x-ray examination and quality of apparatus, are discussed. From the Government primarily a constraint setting policy is expected, in which rule-giving with respect to quality of education and apparatus is highly important. A stimulation of inter-collegial consulting may be expected, in particular in financial sense. A permission policy has to be managed, which ensures centralization of apparatus and centrally performance of x-ray examination as much as possible. Finally warning is given for the effects of excessive fear for radiation which causes refraining of medical necessary examination. The various risk have to be weighed up

  8. Totally Carrying out Zero Defects Quality Control

    Institute of Scientific and Technical Information of China (English)

    ZhangQingwei; CASCPresident

    2004-01-01

    Editorial note: On March 22,1992 the launch of LM-2E launch vehicle with an Australian satellite was terminated. A piece of 0.15 milligram aluminum redundance led to the malfunction of the program distributor, which caused the emergency cutoff after 7 seconds of the ignition of the rocket. To bear in mind the painful lesson, China Aerospace Corporation set out March 22 to be “Space Quality Day” in 1994.

  9. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  10. An experimental system for the quantitative 14C labelling of whole trees in situ [assimilation chamber, control of CO2 level

    International Nuclear Information System (INIS)

    The first part of this paper provides a brief review of the requirements that apply to 14C-labelling chamber technology, particularly for tree labelling, and of the means that can be used to meet them. Two main points are considered: the quality of the plant chamber environment - the necessity of thermal and hygrometric regulations is discussed - and the possibility of determining the exact amount of 14CO2 assimilated by the plant. The authors then describe a simple system allowing the quantitative labelling of entire trees, without temperature- or hygrometry-regulating devices which can be used in the morning. The CO2 concentration is maintained at its natural level throughout the labelling procedure through an injection of cold CO2 operated by an IRGA-driven computer. This system was successfully used for the labelling of grafted walnut trees. (author)

  11. Quality control of solidified intermediate and highly active wastes

    International Nuclear Information System (INIS)

    It is shown that quality control on processed radioactive waste (for temporary storage) is an important component in an extensive waste-quality safety program. The quality controls should follow the following steps: determination of container dimensions and weight; determination of surface contamination; calorimetry for measurement of heat production of highly active waste; determination of gamma flux and temperature distribution on the container surface; and neutron measurement for calculating the transuranic elements content. The various methods are presented and discussed. A possible control system in an intermediate layer is presented. (A.N.K.)

  12. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  13. Target Chamber Manipulator

    Science.gov (United States)

    Tantillo, Anthony; Watson, Matthew

    2015-11-01

    A system has been developed to allow remote actuation of sensors in a high vacuum target chamber used with a particle accelerator. Typically, sensors of various types are placed into the target chamber at specific radial and angular positions relative to the beam line and target. The chamber is then evacuated and the experiments are performed for those sensor positions. Then, the chamber is opened, the sensors are repositioned to new angles or radii, and the process is repeated, with a separate pump-down cycle for each set of sensor positions. The new sensor positioning system allows scientists to pre-set the radii of up to a dozen sensors, and then remotely actuate their angular positions without breaking the vacuum of the target chamber. This reduces the time required to reposition sensors from 6 hours to 1 minute. The sensors are placed into one of two tracks that are separately actuated using vacuum-grade stepping motors. The positions of the sensors are verified using absolute optical rotary encoders, and the positions are accurate to 0.5 degrees. The positions of the sensors are electronically recorded and time-stamped after every change. User control is through a GUI using LabVIEW.

  14. Establishment of an X radiation equipment quality control programme using non invasive meters

    International Nuclear Information System (INIS)

    The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model DiavoltTM, and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests. (author)

  15. Implementation of quality control systematics for personnel monitoring services

    International Nuclear Information System (INIS)

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.)

  16. European quality assurance and quality control for cut-off walls and caps

    International Nuclear Information System (INIS)

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  17. A Quality Analysis of Randomized Controlled Trials about Erectile Dysfunction

    OpenAIRE

    Chung, Jae Hoon; Lee, Jeong Woo; Jo, Jung Ki; Kim, Kyu Shik; Lee, Seung Wook

    2013-01-01

    Purpose A low quality clinical trial could produce errors, and these errors could, in turn, distort the results of the clinical trial. To avoid applying distorted results of trials clinically, a quality analysis of clinical trials is needed. Materials and Methods We selected randomized controlled trials (RCTs) about erectile dysfunction (ED) conducted in Korea using Medline and KoreaMed. Quality assessment of selected RCTs was performed using three assessment tools (Jadad scales, van Tulder s...

  18. Quality evaluation of controlled clinical information service trials.

    OpenAIRE

    Balas, E A; Austin, S. M.; Brown, G.D.; Mitchell, J. A.

    1993-01-01

    Randomized controlled clinical trials are increasingly accepted as tools of computer technology assessment and, therefore, quality evaluation of trials has great theoretical and practical significance. The purpose of this study was to assist the design of evaluation studies and synthesis of published results by developing and validating an easy-to-use quality scoring method. The development of the new scoring system was based on the available quality evaluation methods and the analysis of 19 ...

  19. Quality control of a herb extract using PTR-MS

    Science.gov (United States)

    Jaksch, D.; Hartungen, E.; Mikoviny, T.; Abel, G.; Märk, T. D.

    2004-12-01

    We have developed an objective method for the determination of a herb extract's quality based on headspace measurements by proton-transfer-reaction mass spectrometry (PTR-MS); this quality was checked by a sensory analysis until now. This novel method enables the company [`]Bionorica' to ensure that they are only selling high-quality products and therefore avoid complaints of the customer. The method could be also used for controlling and optimising the production process.

  20. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  1. Quality Changes of Frozen Meat During Storage and Control Measures

    Institute of Scientific and Technical Information of China (English)

    DU Jiangping

    2010-01-01

    The frozen is a common method of meat storage, generally applications in meat industrial. However, the quality of meat still have taken place changes even in the low temperature, This article discussion on the changes of frozen meat quality during freezing storage, and give the corresponding control measures.

  2. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Science.gov (United States)

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  3. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ..., closures, in-process materials, packaging material, labeling, and drug products, and the authority to..., closures, packaging materials, in-process materials, and drug products shall be available to the quality... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit....

  4. Experience in quality control of PET with source of germanium

    International Nuclear Information System (INIS)

    In our hospital, the quality guarantee program in Nuclear Medicine was implemented in 2007. In the section on control quality figure, along with monthly measures, daily tests of sensitivity and uniformity of a Siemens PET-CT Bio graph 6 with a cylindrical Ge68 source. In this work the results of these monthly tests between 2010 and 2012. (Author)

  5. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  6. Quality control in electronic portal imaging devices

    International Nuclear Information System (INIS)

    Purpose/Objective: Pitfalls in the electronic portal imaging routine demonstrate the necessary of a quality assurance program. The aim of this study is to evaluate the limits of various commercially available video based systems in the recognition of mistakes made when positioning radiation fields. In addition, the time stability of the systems was investigated. The parameters used were spatial resolution, contrast difference and geometric distortion. Material and Methods: A special phantom was designed consisting of a box filled with silicon and containing one metal plate with a hole of 20 cm diameter, one metal plate containing small holes of different diameters (0.5 to 10 mm) and step wedges of metal and cork. The images of the big hole provide information about the degree of distortion, those of the small holes, about spatial resolution and those of the step wedges, about contrast difference. The energy of the X-rays was 6, 10, 15 and 25 MeV. Hardcopies on both paper and film were investigated as well as the presentation on the screen. Different available image processing programs were used. The quality standard was given by a port film with copper/plastic cassette exposed with 6 MeV X-rays. Results: The minimum detail diameter which could be delineated with all systems was about 1mm, irrespective of the X-ray's energy. The minimum contrast was found to be depending on the system as well as on the special parameters of the imaging processing method applied. In some cases, the geometric distortion was up to 20%. We observed cloud-like artefacts on the paper hardcopies, which destroyed the detail informations. Conclusion: The quality of the electronic portal imaging devices is lower than that of conventional port films. The comparison of the systems shows differences in detail contrast but not in the spatial resolution. In some cases, significant degrees of distortion were found. It is necessary to have a check program in order to evaluate the differences between

  7. Performance Evaluation Model for Product Quality Control of Vegetable Cooperatives

    Directory of Open Access Journals (Sweden)

    Li Qin

    2013-08-01

    Full Text Available The purpose of this study is to investigate the product quality control performance of vegetable cooperatives in China, using Heilongjiang province as a case. This study applies fuzzy integral theory to develop a comprehensive evaluation model and analyzes the product quality control performance of the vegetable cooperatives. The results show that the performance of vegetable cooperatives in the production process is the highest. That is, vegetable cooperatives have important effect on the performance of product quality control mainly in the production process. Through the large-scale operation and the implementation of standardized production, vegetable cooperatives can effectively transform the decentralized production into the unified production. To exert the role of vegetable cooperatives in the product quality control, the incentive systems and the financial support policies should be improved and actively implement the brand strategy.

  8. Quality controls of radiopharmaceuticals used in nuclear medicine

    International Nuclear Information System (INIS)

    Chromatographic quality controls for Tc-99m; In-113m; I-131; Tl-201 and Ga-67 radiopharmaceuticals are described. Moreover, a chromatographic system which allows to separate different radiopharmaceuticals from In-113m is pointed out. (author)

  9. Research Ship Southern Surveyor Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Southern Surveyor Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  10. NOAA Ship Bell M. Shimada Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Bell M. Shimada Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  11. NOAA Ship Okeanos Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Okeanos Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  12. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  13. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  14. Research Ship Robert Gordon Sproul Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Robert Gordon Sproul Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  15. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. Research Ship T. G. Thompson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship T. G. Thompson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  17. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  19. NOAA Ship David Starr Jordan Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship David Starr Jordan Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  20. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  2. Research Ship Atlantic Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantic Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  3. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. Research Ship New Horizon Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship New Horizon Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  5. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Nathaniel B. Palmer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Nathaniel B. Palmer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  7. Research Ship Laurence M. Gould Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Laurence M. Gould Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  8. Research Ship Aurora Australis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Aurora Australis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  9. Research Ship Healy Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  10. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  11. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  12. Research Ship Melville Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  13. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  14. NOAA Ship Oscar Elton Sette Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Elton Sette Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  15. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. Research Ship Roger Revelle Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Roger Revelle Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  18. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  19. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  20. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. NOAA Ship Henry B. Bigelow Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Henry B. Bigelow Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  2. Quality control system response to stochastic growth of amyloid fibrils.

    Science.gov (United States)

    Pigolotti, Simone; Lizana, Ludvig; Otzen, Daniel; Sneppen, Kim

    2013-05-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system periodically breaks down, allowing for formation of large aggregates. We discuss how these periodic breakdowns may constitute a mechanism for the development of neurodegenerative diseases. PMID:23524241

  3. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  4. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  5. Preparation and quality control of ECD kit

    International Nuclear Information System (INIS)

    ECD Kit for brain imaging after labeling with technetium 99m was prepared according to an optimum conditions, Each vial contains 1 mg of ECD and 0.155 mg of stannous chloride anhydrous SnCl2, 24 mg of Mannitol and 0.5 mg of Na2Ca EDTA, The prepared kit showed high quality satisfying the requirements of international pharmacopoeias from the points of physical, chemical, radiochemical and biological purities, and its validity for human injection. And the labeling yield exceeded 95 % with average value of about 97.63 ± 0.89% for 2mCi /2ml radioactivity , This study also showed that each vial content can be labeled with maximum activity of 99mTc of about 50 mCi (Authors)

  6. The CEA contribution to quality control

    International Nuclear Information System (INIS)

    The Commissariat a l'Energie Atomique has developed original methods and techniques for testing delicate components of the primary circuit of pressure water reactors. These techniques make use of a very wide range of non destructive testing methods: Eddy currents, particularly multiple frequencies, for testing steam generator tubes, gudgeon and other pins focused ultrasonics for testing all the welds of the reactor vessel and its cover plate, mixed welds of steam vessels and generators, low welds of the pressurizer and gudgeon pins from the inside. On site use is effected with specific machines intended either for inspecting the tube bundles of steam generators under the responsibility of INTERCONTROLE Co., or for the complete examination of the reactor vessel by mixed CEA/INTERCONTROLE crews under the responsibility of the CEA. All these operations are subjected to a programme of quality assurance that provides the guaranty of execution complying with the procedures in force

  7. Development of Quality Control Procedures for Lepidoptera

    Science.gov (United States)

    Lepidopteran species are among the most destructive insect pests throughout the world. The sterile insect technique (SIT), within an area-wide integrated pest management (AW-IPM) approach, has proven to be a valuable tactic for controlling and eradicating important moth pests. Improving laboratory...

  8. Quality control of radiopharmaceuticals. Pt. 2

    International Nuclear Information System (INIS)

    In this article, activities of the Federal Health Office are reported: a) Dictionary-like compilations of methods for control of radiochemical impurities; b) Development of analytical separation and determination procedures as well as measuring methods for the quantification of impurities; c) Market analysis of commercially available radiopharmaceuticals. (RB)

  9. Chamber transport

    Energy Technology Data Exchange (ETDEWEB)

    OLSON,CRAIG L.

    2000-05-17

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system.

  10. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard;

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  11. Using statistical quality control techniques to monitor blood glucose levels.

    OpenAIRE

    Oniki, T. A.; Clemmer, T. P.; Arthur, L. K.; Linford, L. H.

    1995-01-01

    Continuous Quality Improvement techniques developed in industry are increasingly being applied to the medical field. Statistical process control charts are a CQI technique aimed at monitoring a process and its variability. At our hospital, statistical quality control charts are being constructed from laboratory blood glucose measurements of patients receiving enteral or parenteral nutrition. The charts will be used to monitor glucose levels, reveal variations, and illustrate the effects of ne...

  12. Biofuel quality control by portable XRF-analyser

    OpenAIRE

    Golubev, Vitaly

    2015-01-01

    The objective of this thesis project was to find out feasibility of using a handheld XRF-analyser in solid biofuel quality control, particularly for recovered wood. Global biomass supply is estimated to grow rapidly, creating demand for automatic quality control systems. X-ray fluorescent technology brings about quick, accurate and non-destructive elemental analysis. Recovered wood fuel is challenging for combustion due to high levels of contaminants. During this work a list of challenging ch...

  13. Preserving organelle vitality: peroxisomal quality control mechanisms in yeast

    OpenAIRE

    Aksam, Eda Bener; de Vries, Bart; van der Klei, Ida J.; Kiel, Jan A. K. W.

    2009-01-01

    Cellular proteins and organelles such as peroxisomes are under continuous quality control. Upon synthesis in the cytosol, peroxisomal proteins are kept in an import-competent state by chaperones or specific proteins with an analogous function to prevent degradation by the ubiquitin-proteasome system. During protein translocation into the organelle, the peroxisomal targeting signal receptors (Pex5, Pex20) are also continuously undergoing quality control to enable efficient functioning of the t...

  14. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  15. Production process and quality control for the HTTR fuel

    International Nuclear Information System (INIS)

    Development of the production and inspection technology for High Temperature Engineering Test Reactor (HTTR) fuel has been carried out by cooperative work between Japan Atomic Energy Research Institute (JAERI) and Nuclear Fuel Industries, Ltd (NFI). The performance and the quality level of the developed fuel are well established to meet the design requirements of the HTTR. For the commercial scale production of the fuel, statistical quality control and quality assurance must be carefully considered in order to assure the safety of the HTTR. It is also important to produce the fuel under well controlled process condition. To meet these requirements in the production of the HTTR fuel, a new production process and quality control system is to be introduced in the new facilities. The main feature of the system is a computer integrated control system. Process control data at each production stage of products and semi-products are all gathered by terminal computers and processed by a host computer. The processed information is effectively used for the production, quality and accountancy control. With the aid of this system, all the products will be easily traceable from starting materials to final stages and the statistical evaluation of the quality of products becomes more reliable. (author). 8 figs

  16. Quality control in computed tomography X-ray scanners

    International Nuclear Information System (INIS)

    Practical methods of estimating computed tomography X-ray scanner imaging performance treat the scanner as a black box, the measurements usually being non-invasive. The performance of individual components or groups of components within the system is not usually measured. The digital nature of the imaging process allows direct numerical assessment of the actual imaging parameters. This approach is used for type and acceptance testing as well as quality control, the type and acceptance tests providing the baseline for subsequent quality control measurements. The usual X-ray imaging parameters of noise, resolution and dose can all be used for quality control purposes, but the relative emphasis between these parameters will differ when compared with type or acceptance testing. Other simple measurements may be of equal use. All manufacturers suggest quality control protocols of varying complexity using a wide range of phantom designs. Where quality control is undertaken routinely, it is usually the manufacturer's protocols that are followed. It is pertinent to ask whether the quality control measurements currently suggested are necessary and/or sufficient. (author)

  17. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement. PMID:24112531

  18. Production And Quality Control Of Radiopharmaceutical 18F-FDG

    International Nuclear Information System (INIS)

    18F-FDG is a radiopharmaceutical for imaging diagnosis with PET/CT in Nuclear Medicine. Criteria of injection pharmaceuticals are the highest standards. So, quality assurance and quality control must be followed very strictly. The selection of the procedure for 18F-FDG has based on several criteria: high chemical efficiency, short synthesis time, toxic component free and etc. The quality control of 18F-FDG consist many fields such as: nuclear physic (nuclear purity), radiochemistry (radionuclear purity, radiochemical purity), chemistry (chemical purity), radiation measurement (half life), microbiology (pyrogen, endotoxin), etc. which is following USP, BP or EP. (author)

  19. Control measures for NDE and quality in project construction

    International Nuclear Information System (INIS)

    Projects are constructed with huge investments in money, time and effort and therefore it is essential that they perform well during the intended life period. The reliability so expected can only be ensured by achieving the desired quality in construction. Quality mainly depends upon the effective controlling of materials used in construction, work procedures adopted, personnel performing the important functions and work environment and also ensuring proper documentation. The above fact has been well recognized during construction of the Project at Kalpakkam under Dept. of Atomic Energy. The control measures which have been designed and successfully implemented for achieving the quality are presented. (author)

  20. Quality control of scintillation cameras (planar and SPECT)

    International Nuclear Information System (INIS)

    Regular quality control is one of the corner stones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and SPECT imaging system up to now, however only minor attenuation has been given to the assessment of the performance of imaging systems. In this research we are going to discuss a comprehensive set of test procedures including regular quality control. Our purpose is to go through analysis of the methods and results then to test our hypothesis which state that there is strong relationship between regular and proper evaluation of quality control and the continuity of better medical services in nuclear medicine department. The selection of the tests is discussed and the tests are described, then results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving image table, and to both detector with a large field of view and detectors with a small field of view. The tests presented on this research do not required special phantoms or sources other than those used for quality control of stationary gamma camera and SPECT. They can be applied for acceptance testing and for performance testing in a regular quality assurance program. The data has been evaluated based on me diso software in comparing with IAEA expert software and system specification within the reference values. Our final results confirm our hypothesis, there are some comments about the characteristics and performance of this system that being observed and solved, then a departmental protocol for routine quality control (Q.C) has being established.(Author)

  1. Quality control standards in PGD and PGS.

    Science.gov (United States)

    SenGupta, S B; Dhanjal, S; Harper, J C

    2016-03-01

    Preimplantation genetic diagnosis (PGD) aims to test the embryo for specific conditions before implantation in couples at risk of transmitting genetic abnormality to their offspring. The couple must undergo IVF procedures to generate embryos in vitro. The embryos can be biopsied at either the zygote, cleavage or blastocyst stage. Preimplantation genetic screening uses the same technology to screen for chromosome abnormalities in embryos from patients undergoing IVF procedures as a method of embryo selection. Fluorescence in-situ hybridization was originally used for chromosome analysis, but has now been replaced by array comparative genomic hybridization or next generation sequencing. For the diagnosis of single gene defects, polymerase chain reaction is used and has become highly developed; however, single nucleotide polymorphism arrays for karyomapping have recently been introduced. A partnership between IVF laboratories and diagnostic centres is required to carry out PGD and preimplantation genetic screening. Accreditation of PGD diagnostic laboratories is important. Accreditation gives IVF centres an assurance that the diagnostic tests conform to specified standards. ISO 15189 is an international laboratory standard specific for medical laboratories. A requirement for accreditation is to participate in external quality assessment schemes. PMID:26776824

  2. Quality control in diagnostic mammography: myths, realities and their importance in the final image quality

    International Nuclear Information System (INIS)

    Mammography is the most used tool for early detection of breast cancer and reduce mortality from this cause. Studies with ionizing radiation it is important that be justified and provide a quality image to make the diagnosis, to get more benefits and fewer risks. The problem is the difficult to obtain an image of the breast. Therefore, the commitment to quality mammography is to maximize the contrast, definition, resolution and reliability, thus minimizing noise and dose. A mammogram performed without quality don't detect early breast cancer and the study doesn't have sense. Quality mammography requires trained and experienced staff, modern equipment and in good conditions, correct positioning, right technical factors and appropriate viewing conditions. In addition, quality programs are required to reach to ensure quality, control in testing techniques and image quality. (author)

  3. Quality control and quality assurance of micromegas readout boards for the ATLAS New Small Wheel

    CERN Document Server

    Nanda, Amit

    2016-01-01

    The resistive anode boards of the Micromegas detectors for ATLAS NSW upgrade, will be produced in industries. The anode boards will be thoroughly evaluated at CERN following a detailed quality control and quality assurance (QA/QC) procedure. The report describes thoroughly the procedures and the design of a small QC tool for easier measurements of electrical properties of the readout boards.

  4. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs. PMID:10138526

  5. Measures for a quality combustion (combustion chamber exit and downstream); Mesures pour une combustion de qualite (sortie de chambre de combustion et en aval)

    Energy Technology Data Exchange (ETDEWEB)

    Epinat, G. [APAVE Lyonnaise, 69 (France)

    1996-12-31

    After a review of the different pollutants related to the various types of stationary and mobile combustion processes (stoichiometric, reducing and oxidizing combustion), measures and analyses than may be used to ensure the quality and efficiency of combustion processes are reviewed: opacimeters, UV analyzers, etc. The regulation and control equipment for combustion systems are then listed, according to the generator capacity level

  6. Quality control of environmental radiation monitoring process

    International Nuclear Information System (INIS)

    This report summarizes for the period (January/2003 to September 2003) the analytical results of the Environmental Monitoring Program- Centro de Desenvolvimento da Tecnologia Nuclear - CDTN. A statistical treatment using control graphs for periodicity and tendency analysis according to temporal variation is also carried out. Moreover, a comparison of radioactive and stable elements concentrations with the derived and intake limits for ingestion and inhalation recommended by Comissao Nacional de Energia Nuclear, Fundacao Estatual do Meio Ambiente (FEAM) e Instituto Brasileiro do Meio Ambiente (IBAMA) is performed. The results are compliant with those recommended by the legislation. (author)

  7. Quality control and quality assurance in radiation medicine in the Republic of Moldova

    International Nuclear Information System (INIS)

    Quality Health care results from translating fundamental bench discoveries and making them available to patients. During the past decade, 'molecular imaging' has emerged both as a new tool/technology and as a research and clinical discipline. Molecular imaging is an interdisciplinary approach involving biologist, physicist, physicians, mathematicians, radio chemists and other specialists who have joined forces for better understanding and visualizing of both normal physiological processes and the molecular processes preceding the morphological manifestations of disease in vivo. It is interesting to note, that despite major advances in imaging technology, cancer mortality has remained largely unchanged over the last three decades. Imaging has thus far enabled us to look through a magnifying glass at disease processes but has failed to dramatically influence disease outcomes. Emerging data suggest that molecular PET imaging is about to change this situation. Quality assurance is based on monitoring, measuring, evaluation, verification and recording of quantities, parameters and facts significant from the point of view of Radiation Protection. Quality assurance programs shall be established that provide, as appropriate: adequate assurance that the specified requirements relating to protection and safety are satisfied and quality control mechanisms and procedures for reviewing and assessing the overall effectiveness of protection and safety. The Republic of Moldova with the support of the International Atomic Energy Agency perform the quality assurance and quality control procedures in the frame of the Technical Cooperation Regional Projects RER-6-012 ''Quality Assurance and Quality Control in Radiation Oncology'', and RER-6-011 'Thematic Program on Nuclear Medicine'. The Ministry of Health and Social Protection carry out the National Project 'Ensuring Radiation Safety and Protection of the Patients' the principal goal being the Quality Assurance and Quality Control in

  8. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  9. [Our experience with outside laboratory quality control].

    Science.gov (United States)

    Dochev, D; Arakasheva, V; Nashkov, A; Tsachev, K

    1979-01-01

    The results from the national outside laboratory qualitative control of the clinical diagnostic laboratory investigations for the period September 1975 -- May 1977 were described. The following interlaboratory discrepancy was found on base of a systematic analysis of the data from the last two ring-like check-ups, November 1976 and May 1977, exressed by the variation coefficient (V.C. %); total protein, sodium, potassium and chlorides -- under 10%; cholesterol, urea and total fats -- between 10 and 20%; calcium, phosphorus, iron and creatinine -- over 20%. The highest per cent of admissible results are found with total protein -- to 85%; cholesterol -- to 70.38%; glucosa -- to 73.17%, urea -- to 69.23%, potassium -- to 59.46%, chlorides -- to 57.9%. With sodium, phosphorus, calcium, iron creatinine and uric acid the "admissibility" fluctuates about or under 50 per cent. The values of the qualitative-control indices discussed are comparable with the values obtained from them in the interlaboratory comparisons of other countries. PMID:494628

  10. Quality control of cemented waste forms

    Energy Technology Data Exchange (ETDEWEB)

    Slate, L.J.

    1994-12-31

    To insure that cemented radwaste remains immobilized after disposal, certain standards have been set in Europe by the Commission of the European Communities. One such standard is compressive strength. If the compressive strength can be predicted during the early curing stages, time and money can be saved and the quality of the final waste form guaranteed. It was determined that the 7- and 28-day compressive strength from radwaste cementation can be predicted during the mixing and early curing stages by at least three methods. The three that were studied were maturity, rheology, and impedance. Maturity is a temperature-to-time measurement, rheology is a shear stress-to-shear rate measurement, and impedance is the opposition offered to the flow of alternating current. These three methods were employed on five different cemented radwaste concentrations with three different water-to-cement ratios; thus, a total of 15 different mix designs were considered. The results showed that the impedance was the easiest to employ for an on-line process. The results of the impedance method showed a very good relationship between impedance and water-to-cement ratio; therefore, an accurate prediction of compressive strength of cemented radwaste can be drawn from this method. The results of the theology method were very good. The method showed that concrete conforms to the Bingham plastic rheologic model, and the theology method can be used to predict the compressive strength of cemented radwaste, but may be too cumbersome. The results of the maturity method were shown to be limited in accuracy for determining compressive strength.

  11. Quality control of cast brake discs

    Directory of Open Access Journals (Sweden)

    M. Stawarz

    2008-04-01

    Full Text Available The largest industrial application so far have the gray cast irons which are characterized by low tensile and bending strength, while at the same time they have good ultimate comprehensive strength. Additionally, the fatigue strength of gray cast irons is comparatively low and they are only to some extend sensitive for the surface waters effects. Cast iron is the material, which is comparatively easy to be processed, and for this reason – it is not expensive. Brake discs are exploited in particularly hard conditions. They must be resistant both against the thermal fatigue and abrasion wearing (at dry friction as well as against seizing, corrosion and mechanical load [1-3]. The gray cast iron, better than other materials, fulfills all the requirements necessary for making the material for the casts resistant against such tough conditions. This work reflects the researches aiming to define the quality of cast brake discs (ventilated and non-ventilated ones upon a period of their exploitation in real conditions. The following researches were performed: evaluations of the disc surface condition, measurement of disc thickness, examination of run – out flank and metallographic analysis. In order to more detailed recognition of mechanisms and reasons of brake discs wearing in real conditions, one should conduct additional examinations: computer analysis of the microstructure, chemical composition analysis, etc., as well as study of the technology of their production in foundries, where they are manufactured [4]. By obtaining the full set of the mentioned above data one can draw final conclusions and remove causes of possible defects.

  12. 21 CFR 111.105 - What must quality control personnel do?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving...

  13. Advanced methods of quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Under pressure of current economic and electricity market situation utilities implement more demanding fuel utilization schemes including higher burn ups and thermal rates, longer fuel cycles and usage of Mo fuel. Therefore, fuel vendors have recently initiated new R and D programmes aimed at improving fuel quality, design and materials to produce robust and reliable fuel. In the beginning of commercial fuel fabrication, emphasis was given to advancements in Quality Control/Quality Assurance related mainly to product itself. During recent years, emphasis was transferred to improvements in process control and to implementation of overall Total Quality Management (TQM) programmes. In the area of fuel quality control, statistical control methods are now widely implemented replacing 100% inspection. This evolution, some practical examples and IAEA activities are described in the paper. The paper presents major findings of the latest IAEA Technical Meetings (TMs) and training courses in the area with emphasis on information received at the TM and training course held in 1999 and other latest publications to provide an overview of new developments in process/quality control, their implementation and results obtained including new approaches to QC

  14. Statistical Process Control: Going to the Limit for Quality.

    Science.gov (United States)

    Training, 1987

    1987-01-01

    Defines the concept of statistical process control, a quality control method used especially in manufacturing. Generally, concept users set specific standard levels that must be met. Makes the point that although employees work directly with the method, management is responsible for its success within the plant. (CH)

  15. Design and implementation of the STKOS quality-control system

    Institute of Scientific and Technical Information of China (English)

    Haixia; SUN; Danya; LI; Junlian; LI; Sizhu; WU; Tiejun; HU; Qing; QIAN

    2015-01-01

    Purpose: The aim of this study is to develop and implement a quality-control system to ensure authority control of the different knowledge units for the Scientific & Technological Knowledge Organization Systems(STKOS).Design/methodology/approach: First, we analyzed quality-control requirements based on the construction of the STKOS Metathesaurus. Then we designed a quality-control framework, the task management and transfer mechanism, and a service model. Afterwards, we carried out the experiments to check the rules and algorithms used in the system. Finally, the system was developed, and gradually optimized during its service.Findings: The quality-control system supports collaborative knowledge construction, as well as consistency checks of knowledge units with different granularity levels, including terminologies, relationships, and concepts. The system can be flexibly configured.Research limitations: The system is oriented to an English-language knowledge organization system, and may not perform well with Chinese-language systems and ontologies.Practical implications: The system can be used to support the construction of a single knowledge organization system, as well as data warehousing and interoperable knowledge organization systems. Originality/value: The STKOS quality-control system not only focuses on content building for the knowledge system, but also supports collaborative task management.

  16. Analysis of Information Quality in event triggered Smart Grid Control

    DEFF Research Database (Denmark)

    Kristensen, Thomas le Fevre; Olsen, Rasmus Løvenstein; Rasmussen, Jakob Gulddahl

    2015-01-01

    dependability of existing networks. We develop models for network delays and information dynamics, and uses these to model information quality for three given information access schemes in an event triggered control scenario. We analyse the impact of model parameters, and show how optimal choice of information...... access scheme depends on network conditions as well as trade-offs between information quality, network resources and control reactivity.......The integration of renewable energy sources into the power grid requires added control intelligence which imposes new communication requirements onto the future power grid. Since large scale implementation of new communication infrastructure is infeasible, we consider methods of increasing...

  17. Quality control of rain data used for urban runoff systems

    DEFF Research Database (Denmark)

    Jørgensen, H. K.; Rosenørn, S.; Madsen, Henrik;

    1998-01-01

    When improving software packages such as MOUSE and SAMBA for designing sewers and storage basins, and simulating overflows and flooding the quality of the input becomes important. The essential input to these modelling tools are the historical rain series. This paper presents the procedures for...... collection and quality control of rain data from a network of tipping bucket rain gauges in Denmark carried out by the Danish Meteorological Institute. During rain, the RIMCO gauge counts the number of tips teach of 0.2 mm of precipitation) every minute, The quality control of the rain data includes an...... automatic and a manual bit marking, where the automatic control basically is pointing out minutes with extreme intensities. In the manual control, the maximum intensities as well as the daily totals of precipitation are inspected, using weather charts, intensity plots and precipitation sums of nearby...

  18. Quality control of systems of portal imaging; Control de calidad de sistemas de imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Olasolo Alonso, J.; Martin Albina, M. L.; Otal Palacin, A.; Fuentemilla Urio, N.; Miquelez Alonso, S.; Pellejero Pellejero, S.; Maneru Camara, F.; Lozares Cordero, S.; Rubio Arroniz, A.

    2013-07-01

    The importance of accuracy and reproducibility of the positioning of the patient for the radiotherapy treatment, makes key the image quality of the image device portal used for the verification of such positioning. the objective of this work is the implementation of a procedure of quality control that easily and quickly verify the main parameters of image quality of the EPID. (Author)

  19. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    Energy Technology Data Exchange (ETDEWEB)

    Correa, E.L.; Vivolo, V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Avenida Professor Lineu Prestes 2242, Cidade Universitaria, Sao Paulo, SP (Brazil); Potiens, M.P.A., E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN), Avenida Professor Lineu Prestes 2242, Cidade Universitaria, Sao Paulo, SP (Brazil)

    2012-07-15

    This study presents the results of the establishment of a quality control program developed and applied for the X-ray system of the Calibration Laboratory of IPEN. The X-ray standard beams, mammography level, using molybdenum and aluminum as additional filtration were established after the application of this quality control and the spectrometry of these qualities was made. The reference ionization chamber has traceability to the PTB. The radiation qualities RQR-M, RQA-M, RQN-M and RQB-M, following the recommendations of the IEC 61267 and the IAEA TRS 457 were established. - Highlights: Black-Right-Pointing-Pointer Determination of the additional filtration for each mammography radiation quality. Black-Right-Pointing-Pointer Determination of the KQ values for the WAV and WMV radiation qualities. Black-Right-Pointing-Pointer Determination of the air-kerma rates for all radiation qualities. Black-Right-Pointing-Pointer The uncertainties have been calculated using the type A and type B uncertainties. Black-Right-Pointing-Pointer Establishment of the qualities that use a PMMA phantom (WAN, WAB, WMN and WMB).

  20. Application Of Electronic Nose And Ion Mobility Spectrometer To Quality Control Of Spice Mixtures

    International Nuclear Information System (INIS)

    The aim of the paper is to demonstrate the application of electronic nose (e-nose) and ion mobility spectrometry (IMS) to quality control and to find out product adulteration of spice mixtures. Therefore the gaseous head space phase of four different spice mixtures (spices for sausages and saveloy) was differed from original composition and product adulteration. In this set of experiments metal-oxide type e-nose (KAMINA-type) has been used, and characteristic patterns of data corresponding to various complex odors of the four different spice mixtures were generated. Simultaneously an ion mobility spectrometer was coupled also to an emission chamber for the detection of gaseous components of spice mixtures. The two main methods that have been used show a clear discrimination between the original spice mixtures and product adulteration could be distinguished from original spice mixtures.

  1. Design and Construction of a Test Phantom for Screen/Film Mammography Quality Control

    International Nuclear Information System (INIS)

    A 10 x 10 x 4 cm Lucite phantom for quality control tests in mammography has been designed and built. It contains internal elements to quantify contrast and resolution, a mixture of talc and Lucite fibers to simulate the breast architecture, a 9-step aluminum wedge to verify the constancy of the film developing process, and metallic foils to evaluate kVp. Associated with an ionization chamber, the mean glandular dose can be evaluated. Its performance has been compared against the phantom accredited by the American College of Radiology. For a series of kV, both phantoms OD are similar within 5%. The step wedge can detect developer temperature changes of ±1 deg. C. Relative metal foils/acrylic OD permits to calculate kVp with precision of ±0.43 kV. Radiological measurements have been interpreted by numerical calculations

  2. Quality control in a SSDL/NCL

    International Nuclear Information System (INIS)

    The rapid development in nuclear science and technology in particular in radiotherapy and industrial applications of ionizing radiation demands everywhere standardization and permanent control dosimetry. A national calibration laboratory for ionizing radiation must be designated as such by the appropriate authorities. The responsible government authorities should apply the Agency's Radiation Protection Standards and Measures and/or the national ones (when adequate) for the safe use of all kind of ionizing radiation. They should issue to the calibration laboratory a corresponding working licence when the irradiation facilities of the calibration laboratory become operational. The basic aim of a national calibration laboratory is to improve accuracy in radiation dosimetry and should therefore maintain and apply dosimetric equipment of the present state of art, i.e. secondary standards, for calibration of radiation measuring instrumentation for the whole country. It should also undertake measurements and calibrations of the output of radiation sources and installations in the field, whenever this will be required. In addition the calibration laboratory should be the preferred place for receiving training in applied radiation dosimetry. It should give advice to users on up-to-date measurement procedures and techniques. It should promote everywhere the safe application of ionizing radiation by supporting users of ionizing radiation for creation and distribution of better knowledge in the field of applied radiation dosimetry. The strict application of Radiation Protection Standards and Measures will ensure the protection of health and safety of both, the radiation workers and the individuals of the general public, without imposing undue burdens upon the use of ionizing radiation

  3. Pupillary block glaucoma following implantation of a posterior chamber pseudophakos in the anterior chamber.

    Directory of Open Access Journals (Sweden)

    Mandal Anil

    2002-01-01

    Full Text Available Pupillary block glaucoma is a common complication of cataract surgery, especially following anterior chamber intraocular lens implantation. We report a case of pupillary block glaucoma with a posterior chamber IOL that was implanted in the anterior chamber following a complicated extracapsular cataract extraction. The case was successfully managed by explantation of the posterior chamber lens, anterior vitrectomy, peripheral iridectomy and secondary anterior chamber intraocular lens implantation. The intraocular pressure was controlled with a single topical antiglaucoma medication.

  4. Model based control charts in stage 1 quality control

    OpenAIRE

    Koning, Alex

    1999-01-01

    textabstractIn this paper a general method of constructing control charts for preliminary analysis of individual observations is presented, which is based on recursive score residuals. A simulation study shows that certain implementations of these charts are highly effective in detecting assignable causes.

  5. Indoor air quality control techniques. Radon, formaldehyde, combustion products

    International Nuclear Information System (INIS)

    This book reviews and evaluates existing indoor air quality control techniques. The indoor air pollutants of most concern are radon, formaldehyde, and certain combustion products-nitrogen dioxide, carbon monoxide, carbon dioxide, and various respirable particles. Many techniques exist to control the concentration of these pollutants and other indoor pollutants that are only now being recognized as significant. The purpose of the book is to provide a current review and evaluation of these control techniques

  6. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors....../kg. Measurement compatibility is obtained by control of traceability to certified reference materials, (C) 1994 Wiley-Liss, Inc....

  7. 75 FR 80066 - Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed Information...

    Science.gov (United States)

    2010-12-21

    ... URBAN DEVELOPMENT Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed.... This Notice also lists the following information: Title of Proposal: Quality Control Requirements for... lenders, since these institutions must also conduct quality control on all loans they originate...

  8. 78 FR 69103 - 30-Day Notice of Proposed Information Collection: Quality Control for Rental Assistance Subsidy...

    Science.gov (United States)

    2013-11-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Quality Control for Rental... Information Collection: Quality Control for Rental Assistance Subsidy Determinations. OMB Approval Number... Quality Control process involves selecting a nationally representative sample of assisted households...

  9. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos;

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these...... controllers includes a selective virtual impedance loop which is considered to improve sharing of fundamental and harmonic components of load current among the DG units. The sharing improvement is provided at the expense of increasing voltage unbalance and harmonic distortion. Thus, the secondary control...... level is applied to manage the compensation of SLB voltage unbalance and harmonics by sending proper control signals to the primary level. DGs compensation efforts are controlled locally at the primary level. The system design procedure for selecting proper control parameters is discussed. Simulation...

  10. Certification, accreditation, and quality control in behavior analysis

    OpenAIRE

    Moore, J.; Shook, G L

    2001-01-01

    Implementing quality control measures in the discipline and professional practice of behavior analysis is a challenging, but nevertheless important, step in the evolution of our field. The Association for Behavior Analysis currently seeks to ensure quality in behavior analysis by sponsoring an accreditation program for graduate academic programs and by promoting certification of individual practitioners. The accreditation reviews are conducted by ABA, whereas certification status is awarded b...

  11. Quality control for diagnostic oral microbiology laboratories in European countries

    OpenAIRE

    Rautemaa-Richardson, Riina; Wil A van der Reijden; Dahlen, Gunnar; Andrew J. Smith

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB) Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into...

  12. Quality control of radioactive waste disposal container for borehole project

    International Nuclear Information System (INIS)

    This paper explained quality control of radioactive disposal container for the borehole project. Non-destructive Testing (NDT) is one of the quality tool used for evaluating the product. The disposal container is made of 316L stainless steel. The suitable NDT method for this object is radiography, ultrasonic, penetrant and eddy current testing. This container will be filled with radioactive capsules and cement mortar is grouted to fill the gap. The results of NDT measurements are explained and discussed. (author)

  13. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R

    2007-01-15

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future.

  14. Theoretical White Dwarf Spectra via the Internet: Quality Control

    Science.gov (United States)

    Ringat, E.; Reindl, N.

    2013-01-01

    The first decade of the Virtual Observatory (VO) built up services and tools for data conservation, handling, processing, analysis, etc. A new challenge in the immensely growing VO in operation is continuous quality control at different authority levels. Here we shed light on various aspects of theoretical white dwarf spectra that are provided via the registered TheoSSA VO service. We present benchmark tests that enable the VO user to judge their quality.

  15. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  16. A hybrid microbial fuel cell stack based on single and double chamber microbial fuel cells for self-sustaining pH control

    Science.gov (United States)

    Yang, Wei; Li, Jun; Ye, Dingding; Zhang, Liang; Zhu, Xun; Liao, Qiang

    2016-02-01

    Proton accumulation in the anode chamber is the major problem that affects the operational stability and electricity generation performance of double chamber microbial fuel cells (MFCs). In this study, a hybrid microbial fuel cell stack (DS-DS stack) based on single (SCMFCs) and double chamber MFCs (DCMFCs) is proposed for self-sustaining pH control in the MFC stack. It is found that the aerobic microbial oxidation of acetate by the biofilm that is attached to the air cathode of SCMFCs is responsible for the self-sustaining removal of accumulated H+ in the effluent of DCMFCs. Compared with the stack that solely consists of SCMFCs (SS-SS stack) or DCMFCs (DD-DD stack), the hybrid stack exhibits the highest electricity output performance and the most effective conversion of acetate into electricity at high power levels. Furthermore, the hybrid stack demonstrates the operation time of 15.7 ± 1.1 h when the operating voltage is above 0.8 V. This value is much higher than that of the DD-DD (8.5 ± 2.4 h) and SS-SS (8.1 ± 1.4 h) stacks, which suggests that the hybrid stack had a good operational stability.

  17. Quality control for exposure assessment in epidemiological studies

    DEFF Research Database (Denmark)

    Bornkessel, C; Blettner, M; Breckenkamp, J;

    2010-01-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy was...... developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded...... from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly....

  18. Low cost breast phantom prototype for quality control mammography

    International Nuclear Information System (INIS)

    A low cost breast phantom prototype for quality control in mammography was designed and built. The phantom was formed by acrylic and wax rectangular plates. Several pieces were inserted in order to simulated fibers, micro-calcifications and tumor masses, and to assessment the spatial and contrast resolutions. Different quality control imaging tests were carried out in 3 mammography equipment in clinical use comparing the home-made phantom with a commercial phantom. The results showed that our prototype can be used for mammography quality control according to the Brazilian guideline (regulation 453/98). The aim of this work is propose a low cost breast phantom for a future use in Brazilian hospitals. (author)

  19. CT dosimetry and quality control of its operation

    International Nuclear Information System (INIS)

    This thesis focuses on the dosimetry of a scanner, quality control of its operations and the development of a protocol. It allowed us the mastery of the art scanner and participation in all quality controls with appropriate ghosts. CT is a radiographic examination sophisticated and accurate, widely used to screen for various diseases, among other cancer. We worked on the dosimetry of a scanner and we have made simulations with a program called Impact that calculates the CT CTDI and the PDL and compared with values displayed on the console. Similarly, the software calculates the absorbed dose and compared with that calculated by Caldose X. This work is complemented by the development of a protocol with the quality control procedures of the image and dosimetry in chronological order.

  20. The Quality Control of the LHC Continuous Cryostat Interconnections

    CERN Document Server

    Bertinelli, F; Bozzini, D; Cruikshank, P; Fessia, P; Grimaud, A; Kotarba, A; Maan, W; Olek, S; Poncet, A; Russenschuck, Stephan; Savary, F; Sulek, Z; Tock, J P; Tommasini, D; Vaudaux, L; Williams, L

    2008-01-01

    The interconnections between the Large Hadron Collider (LHC) magnets have required some 40 000 TIG welded joints and 65 000 electrical splices. At the level of single joints and splices, non-destructive techniques find limited application: quality control is based on the qualification of the process and of operators, on the recording of production parameters and on production samples. Visual inspection and process audits were the main techniques used. At the level of an extended chain of joints and splices - from a 53.5 m half-cell to a complete 2.7 km arc sector - quality control is based on vacuum leak tests, electrical tests and RF microwave reflectometry that progressively validated the work performed. Subsequent pressure tests, cryogenic circuits flushing with high pressure helium and cool-downs revealed a few unseen or new defects. This paper presents an overview of the quality control techniques used, seeking lessons applicable to similar large, complex projects.

  1. Methods of Statistical Control for Groundwater Quality Indicators

    Science.gov (United States)

    Yankovich, E.; Nevidimova, O.; Yankovich, K.

    2016-06-01

    The article describes the results of conducted groundwater quality control. Controlled quality indicators included the following microelements - barium, manganese, iron, mercury, iodine, chromium, strontium, etc. Quality control charts - X-bar chart and R chart - were built. For the upper and the lower threshold limits, maximum permissible concentration of components in water and the lower limit of their biologically significant concentration, respectively, were selected. The charts analysis has shown that the levels of microelements content in water at the area of study are stable. Most elements in the underground water are contained in concentrations, significant for human organisms consuming the water. For example, such elements as Ba, Mn, Fe have concentrations that exceed maximum permissible levels for drinking water.

  2. Development and use of reference materials and quality control materials

    International Nuclear Information System (INIS)

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose

  3. Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kapanen, Mika [Radiation and Nuclear Safety Authority (STUK), Laippatie 4, 00881 Helsinki (Finland); Tenhunen, Mikko [Department of Oncology, Helsinki University Central Hospital, Haartmaninkatu 4, 00029 Helsinki (Finland); Haemaelaeinen, Tuomo [Department of Oncology, Helsinki University Central Hospital, Haartmaninkatu 4, 00029 Helsinki (Finland); Sipilae, Petri [Radiation and Nuclear Safety Authority (STUK), Laippatie 4, 00881 Helsinki (Finland); Parkkinen, Ritva [Radiation and Nuclear Safety Authority (STUK), Laippatie 4, 00881 Helsinki (Finland); Jaervinen, Hannu [Radiation and Nuclear Safety Authority (STUK), Laippatie 4, 00881 Helsinki (Finland)

    2006-07-21

    Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and long-term drifts in outputs were quantified by fitting empirical mathematical models to the QC measurements. Normally, long-term drifts were well ({<=}1%) modelled by either a straight line or a single-exponential function. A drift of 2% occurred in 18 {+-} 12 months. The shortest drift times of only 2-3 months were observed for some new accelerators just after the commissioning but they stabilized during the first 2-3 years. The short-term reproducibility and the long-term stability of local constancy checks, carried out with a sealed plane parallel ion chamber, were also estimated by fitting empirical models to the QC measurements. The reproducibility was 0.2-0.5% depending on the positioning practice of a device. Long-term instabilities of about 0.3%/month were observed for some checking devices. The reproducibility of local absorbed dose measurements was estimated to be about 0.5%. The proposed empirical model fitting of QC data facilitates the recognition of erroneous QC measurements and abnormal output behaviour, caused by malfunctions, offering a tool to improve dose control.

  4. Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements

    International Nuclear Information System (INIS)

    Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and long-term drifts in outputs were quantified by fitting empirical mathematical models to the QC measurements. Normally, long-term drifts were well (≤1%) modelled by either a straight line or a single-exponential function. A drift of 2% occurred in 18 ± 12 months. The shortest drift times of only 2-3 months were observed for some new accelerators just after the commissioning but they stabilized during the first 2-3 years. The short-term reproducibility and the long-term stability of local constancy checks, carried out with a sealed plane parallel ion chamber, were also estimated by fitting empirical models to the QC measurements. The reproducibility was 0.2-0.5% depending on the positioning practice of a device. Long-term instabilities of about 0.3%/month were observed for some checking devices. The reproducibility of local absorbed dose measurements was estimated to be about 0.5%. The proposed empirical model fitting of QC data facilitates the recognition of erroneous QC measurements and abnormal output behaviour, caused by malfunctions, offering a tool to improve dose control

  5. Control of weld quality in large welded populations

    International Nuclear Information System (INIS)

    The use of factorial experimental design during weld procedure development, as a statistical tool for the control of weld quality in large welded populations, is investigated. As an example, it is applied to single pass welds made in the laboratory using the spacer to tube attachment geometry present in AGR boilers. The welds have been deposited using a robotic cold wire TIG technique. A replicated 25 factorial welding trial has been designed and evaluated experimentally. Transverse sections have been examined to determine weld penetration quality features. The means and variances of each quality feature have been calculated. Using a standard factorial analysis program the significant effects have been identified and incorporated into control equations. Using these data and having established minimum acceptance criteria. defect rates have been calculated as a function of weld position. The control equations have also been used to revise working point welding conditions, to achieve acceptable weld quality. These equations have also been used in conjunction with the reproducibility measurements to estimate the amount of weld quality variability that can be attributed to process control. (author)

  6. Results of a quality control on non-interventional studies

    Directory of Open Access Journals (Sweden)

    Hundt, Ferdinand

    2011-01-01

    Full Text Available Non-interventional studies (NIS have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM on the execution of non interventional (observational studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP, with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies] – Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres.This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials.

  7. Results of a quality control on non-interventional studies.

    Science.gov (United States)

    Wörz, Karl; Hundt, Ferdinand

    2011-01-01

    Non-interventional studies (NIS) have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM) on the execution of non interventional (observational) studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP), with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies]) - Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut) on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres. This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials. PMID:21863135

  8. Quality

    International Nuclear Information System (INIS)

    What is quality? How do you achieve it? How do you keep it once you have got it. The answer for industry at large is the three-step hierarchy of quality control, quality assurance and Total quality Management. An overview is given of the history of quality movement, illustrated with examples from Schlumberger operations, as well as the oil industry's approach to quality. An introduction of the Schlumberger's quality-associated ClientLink program is presented. 15 figs., 4 ills., 16 refs

  9. DBD Plasma Actuators for Flow Control in Air Vehicles and Jet Engines - Simulation of Flight Conditions in Test Chambers by Density Matching

    Science.gov (United States)

    Ashpis, David E.; Thurman, Douglas R.

    2011-01-01

    Dielectric Barrier Discharge (DBD) Plasma actuators for active flow control in aircraft and jet engines need to be tested in the laboratory to characterize their performance at flight operating conditions. DBD plasma actuators generate a wall-jet electronically by creating weakly ionized plasma, therefore their performance is affected by gas discharge properties, which, in turn, depend on the pressure and temperature at the actuator placement location. Characterization of actuators is initially performed in a laboratory chamber without external flow. The pressure and temperature at the actuator flight operation conditions need to be simultaneously set in the chamber. A simplified approach is desired. It is assumed that the plasma discharge depends only on the gas density, while other temperature effects are assumed to be negligible. Therefore, tests can be performed at room temperature with chamber pressure set to yield the same density as in operating flight conditions. The needed chamber pressures are shown for altitude flight of an air vehicle and for jet engines at sea-level takeoff and altitude cruise conditions. Atmospheric flight conditions are calculated from standard atmosphere with and without shock waves. The engine data was obtained from four generic engine models; 300-, 150-, and 50-passenger (PAX) aircraft engines, and a military jet-fighter engine. The static and total pressure, temperature, and density distributions along the engine were calculated for sea-level takeoff and for altitude cruise conditions. The corresponding chamber pressures needed to test the actuators were calculated. The results show that, to simulate engine component flows at in-flight conditions, plasma actuator should be tested over a wide range of pressures. For the four model engines the range is from 12.4 to 0.03 atm, depending on the placement of the actuator in the engine. For example, if a DBD plasma actuator is to be placed at the compressor exit of a 300 PAX engine, it

  10. [Internal quality control for antimicrobial susceptibility test: an experience feedback].

    Science.gov (United States)

    Vedy, Serge

    2012-01-01

    Internal quality control (IQC) position in antimicrobial susceptibility testing must be evaluated attentively before using. Ours S. aureus ATCC 25923 use during year 2011 has given precious information that can be useful for other laboratories. First, IQC should never be used before checking that all the realisation process steps are controlled. It will then appear that reagents are the most susceptible to give false results. That's what happens in 2.74% of antimicrobial susceptibility test. IQC is then useful to limit their clinical's impact. However, IQC use also shows that quality improvement will be difficult without industrial producer's involvement. PMID:22826843

  11. Procedures for quality control in Doppler ultrasound equipment

    International Nuclear Information System (INIS)

    Different international recommendations suggest an application of quality control programs in ultrasound equipment. However, procedures and reference values for Doppler test are not yet well defined. This work aims to present quantitative and qualitative tests for evaluation of quality control at Doppler ultrasound equipment. The following tests were performed: Doppler Signal Sensitivity; Color Flow Sensitivity; Flow Sensitivity at Depth; Color Flow B-Mode Image Congruency; Directional Discrimination; Accuracy of Flow Velocity Readout and Accuracy of Sample Gate Positioning. The values found will be used as baseline for comparisons over time. (author)

  12. Review of 18F-FDG Synthesis and Quality Control

    OpenAIRE

    Yu, S.

    2006-01-01

    This review article covers a concise account on fludeoxyglucose (18F–FDG) synthesis and quality control procedures with emphasis on practical synthesis Currently, 18F–FDG is the most successful PET radiopharmaceutical so far. The advancement in synthesis and quality control of 18F–FDG, together with its approval by the US FDA and the availability of reimbursement, are probably the main reasons for the flourish of clinical PET over the last 20 years. 18F–FDG can be synthesised by either electr...

  13. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  14. Analytical chemistry measurements quality control program using computer applications

    International Nuclear Information System (INIS)

    An Analytical Chemistry Measurements Quality Control Program assures the reliability of analytical measurements performed at the Barnwell Nuclear Fuel Plant. The program includes training, methods quality control, replicate samples and measurements, mass measurements, interlaboratory sample exchanges, and standards preparation. This program has been designed to meet the requirements of 10CFR70.57. Portions of the program have been automated by using a PDP 11/35 computer system to provide features which are not readily available in manual systems. These include such items as realtime measurement control, computer calculated bias and precision estimates, various surveillance applications, and evaluation of measurement system variables. The efficiency of the computer system has been demonstrated in gathering and assimilating the results of over 1100 quality control samples during a recent cold chemical checkout campaign. These data were used to determine equations for predicting measurements reliability estimates; to evaluate measurement performance of the analysts, equipment, and measurement period; and to provide directions for chemistry methods modifications and additional training requirements. A procedure of replicate sampling and measuring provides random error estimates. The analytical chemistry measurement quality control activities during the campaign represented about 10% of the total analytical chemistry effort

  15. 21 CFR 111.127 - What quality control operations are required for packaging and labeling operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.127 What quality control operations are required for packaging and labeling operations? Quality control operations for packaging...

  16. 21 CFR 111.130 - What quality control operations are required for returned dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.130 What quality control operations are required for returned dietary supplements? Quality control operations for returned...

  17. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  18. Integrated evolutionary computation neural network quality controller for automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Patro, S.; Kolarik, W.J. [Texas Tech Univ., Lubbock, TX (United States). Dept. of Industrial Engineering

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  19. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  20. Study on quality standards of engineering control net

    International Nuclear Information System (INIS)

    Four quality standards of the control net for the map surveying, the control net for constructing and deformation monitoring net have been put forward in the light of the references of the classic free net distributed error and the order deficit one, i.e. precision standard, standards of the total precision and the local one, reliability standard, inner reliability and outer reliability as well as measurement, sensitivity standard and economic standard. (author)