WorldWideScience

Sample records for cervical locking plate

  1. A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up.

    Science.gov (United States)

    Chen, Yuqiao; Lü, Guohua; Wang, Bing; Li, Lei; Kuang, Lei

    2016-07-01

    To evaluate the clinical efficacy and radiological outcomes of anterior cervical discectomy and fusion (ACDF) using self-locking polyetheretherketone (PEEK) cages for treatment of three-level cervical degenerative spondylopathy. Twenty-eight patients underwent three-level ACDF using self-locking stand-alone PEEK cages (group A), and 26 patients underwent three-level ACDF using cages and plate fixation (group B) were reviewed retrospectively. Clinical efficacy was evaluated by pre- and post-operative Japanese Orthopedic Association (JOA) scores and Neck Disability Index (NDI). The operation time, blood loss, surgical results according to Odom's criteria and post-operative dysphagia status were also recorded. Radiological outcomes including fusion, cervical Cobb's lordosis, fused segment angle, disc height, and cage subsidence were assessed. Clinical outcome measures such as dysphagia and fusion rate and the results of surgery evaluated according to Odom's criteria were not statistically significant (P > 0.05) between groups. The operation time was shorter and blood loss was less in group A (P  0.05). Post-operative cage subsidence, the loss of disc height, cervical lordosis and the fused segment angle were relatively higher in group A than group B (P < 0.05). ACDF using self-locking stand-alone cages showed similar clinical results as compared to ACDF using cages and plate fixation for the treatment of three-level cervical degenerative spondylopathy. However, potential long-term problems such as cage subsidence, loss of cervical lordosis and fused segment angle post-operatively were shown to be associated with patients who underwent ACDF using self-locking stand-alone cages.

  2. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  3. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  4. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  5. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  7. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  8. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  9. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  10. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  11. Anterior cervical fusion: the role of anterior plating.

    Science.gov (United States)

    Daffner, Scott D; Wang, Jeffrey C

    2009-01-01

    Treatment of cervical pathology requires a clear understanding of the biomechanical benefits and limitations of cervical plates, their indications, and their associated complications. The use of anterior cervical plates has evolved significantly since their early application in cervical trauma. They have become widely used for anterior cervical decompression and fusion for cervical spondylosis. Plate design has undergone significant refinement and innovation, from the initial unlocked plates requiring bicortical purchase to the latest rotationally and translationally semiconstrained dynamic plates. Excellent clinical results have been reported for single-level anterior cervical decompression and fusion with or without plate fixation; however, the addition of an anterior cervical plate clearly leads to earlier fusion and better clinical results in longer fusions. Longer fusions should ideally consist of corpectomies and strut grafting because the decreased number of fusion surfaces tends to lead to higher fusion rates. Although anterior plate fixation leads to higher fusion rates in fusions of three or more levels, the associated pseudarthrosis rate is still high. The use of dynamic plates, through increased load sharing across the graft and decreased stress shielding, may improve fusion rates, particularly in long fusions. Nevertheless, adjuvant posterior fixation is recommended for fusions of more than three vertebral levels. Anterior plate fixation may be of particular benefit in the management of traumatic injuries, in revision settings, and in the treatment of smokers. Complications unique to plate fixation include hardware breakage and migration as well as ossification of the adjacent disk levels.

  12. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  13. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  14. [Tibiotalocalcaneal arthrodesis using a humeral locking plate].

    Science.gov (United States)

    Cabrera Méndez, M P; Gamba, C; Hernández, E; Molano, J; Andrade, J C

    2016-01-01

    To describe the results of tibiotalocalcáneal arthrodesis (TTC) using a humeral locking plate. A retrospective, observational study was conducted between January 2007 and December 2013 in the Hospital Militar Central de Bogotá. The study included patients with symptomatic osteoarthritis diagnosed clinically and radiologically, and who underwent TTC arthrodesis using a humeral locking plate with a minimum follow up of 6 months. The total number patients was 35, of whom 7 (20%) were women and 28 (80%) men, with a mean age 36.3 years (19.77). 74% with post-traumatic arthritis, most of them secondary to gunshot wounds and fragmentation weapons, and neuropathic in 20%. An autogenous graft was used in 13 cases, and 14 cases using both, with a mean consolidation time of 4.37 months. Complications include, delayed union in 3 cases, and surgical site infection in 4. The postoperative functionality (AOFAS) mean was 66.7/100 points, with a score of 2.35 on a visual analogue pain scale. TTC arthrodesis using a humeral locking plate is a suitable option for fixing this type of arthrodesis, with a low rate of complications, and postoperative results that revealed satisfactory improvement in pain and consolidation. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  15. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  16. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  17. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    Science.gov (United States)

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  18. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  20. Single anterior cervical discectomy and fusion (ACDF) using self- locking stand-alone polyetheretherketone (PEEK) cage: evaluation of pain and health-related quality of life.

    Science.gov (United States)

    Kapetanakis, Stylianos; Thomaidis, Tryfon; Charitoudis, George; Pavlidis, Pavlos; Theodosiadis, Panagiotis; Gkasdaris, Grigorios

    2017-09-01

    Anterior cervical discectomy and fusion (ACDF) constitutes the conventional treatment of cervical disc herniation due to degenerative disc disease (DDD). ACDF with plating presents a variety of complications postoperatively and stand-alone cages are thought to be a promising alternative. The aim of this study was firstly, to analyze prospectively collected data from a sample of patients treated with single ACDF using C-Plus self-locking stand-alone PEEK cage system, without the use of plates or screws, in order to evaluate pain levels of patients, utilizing Neck and Arm Pain scale as an expression of visual analogue scale (VAS). Secondly, we aimed to evaluate health-related quality of life, via the short-form 36 (SF-36) and Neck Disability Index (NDI). Thirty-six patients (19 male and 17 female) with mean age 49.6±7 years old who underwent successful single ACDF using self-locking stand-alone PEEK cage for symptomatic cervical DDD were selected for the study. Neck and Arm pain, as well as SF-36 and NDI were estimated preoperatively and 1, 3, 6, and 12 months postoperatively. Patients underwent preoperative and postoperative clinical, neurological and radiological evaluation. The clinical and radiological outcomes were satisfactory after a minimum 1-year follow-up. All results were statistically important (P<0.05), excluding improvement in NDI measured between 6 and 12 months. SF-36, Neck Pain, as well as Arm Pain featured gradual and constant improvement during follow-up, with best scores presenting at 12 months after surgery, while NDI reached its best at 6 months postoperatively. Generally, all scores showed improvement postoperatively during the different phases of the follow-up. Subsequently, ACDF using C-Plus cervical cage constitutes an effective method for cervical disc herniation treatment, in terms of postoperative improvement on pain levels and health-related quality of life and a safe alternative to the conventional method of treatment for cervical DDD.

  1. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  3. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  4. Anterior cervical decompression and fusion with caspar plate fixation

    International Nuclear Information System (INIS)

    Rehman, L.; Akbar, H.; Das, G.; Hashim, A.S.M.

    2013-01-01

    Objective: To evaluate the role of anterior cervical decompression and fixation with Caspar plating in cervical spine injury on neurological outcome. Study Design: A case series. Place and Duration of Study: Department of Neurosurgery, Jinnah Postgraduate Medical Centre, Karachi, from July 2008 to March 2011. Methodology: Thirty patients admitted with cervical spine injuries were inducted in the study. All cases were evaluated for their clinical features, level of injury and degree of neurological injury was assessed using Frankel grading. Pre and postoperative record with X-rays and MRI were maintained. Cervical traction was applied to patients with sub-luxation. All patients underwent anterior cervical decompression, fusion and Caspar plate fixation. The follow-up period was 6 months with clinical and radiological assessment. Results: Among 30 patients, 24 (80%) were males and 6 (20%) were females. Age ranged from 15 to 55 years. Causes of injury were road traffic accident (n = 20), fall (n = 8) and assault (n = 2). Commonest mode of injury was road traffic accident (66.6%). Postoperative follow-up showed that pain and neurological deficit were improved in 21 patients. There was no improvement in 7 patients, one patient deteriorated and one expired. All patients developed pain at donor site. Conclusion: Anterior decompression, fusion and fixation with Caspar plate is an effective method with good neurological and radiological outcome. However, it is associated with pain at donor site. (author)

  5. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  6. Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Voergård Rasmussen, Katrine Marie; Overgaard, Søren

    2017-01-01

    Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between biomecha......Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between...

  7. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  8. Lateral column lengthening using allograft interposition and cervical plate fixation.

    Science.gov (United States)

    Philbin, Terrence M; Pokabla, Christopher; Berlet, Gregory C

    2008-10-01

    Lateral column lengthening has been used successfully in the treatment of stage II adult-acquired pes planovalgus deformity. The purpose of this study is to review the union rate when allograft material is used and the osteotomy stabilized with a cervical plate. A retrospective review was performed on 28 feet in 26 patients who underwent correction of stage II pes planovalgus deformity using a lateral column lengthening with allograft tricortical iliac crest stabilized with a cervical plate. Patients were evaluated preoperatively and postoperatively using a modified American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale and the Short Form-12 health survey, as well as radiographically by assessing the talonavicular coverage angle. At a mean follow-up of 9 months, the mean total modified AOFAS score and pain subscore were significantly higher (45.6 and 25.0, respectively) versus preoperatively (27.3 and 11.2, respectively). Graft incorporation occurred in all but one case, and the average length of time to union was 10.06 weeks. Complications included 4 hardware removals, 1 nonunion, 1 graft penetration of the calcaneocuboid joint, and 2 cases of calcaneocuboid joint arthritis. Lateral column lengthening using allograft tricortical iliac crest bone graft with cervical plate fixation is a viable option for the correction of acquired pes planovalgus deformity. Allograft bone avoids donor site morbidity of autogenous iliac crest grafts and was not shown to increase rates of nonunion. Cervical plate fixation avoids the necessity of penetrating the graft with a screw and is associated with high patient satisfaction and radiographic union.

  9. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  10. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  11. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  12. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Frich, Lars H; Winther, Annika

    2011-01-01

    There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries....

  13. Surgical treatment of cervical unilateral locked facet in a 9-year-old boy: A case report

    Directory of Open Access Journals (Sweden)

    Mutlu Cobanoglu

    2015-01-01

    Full Text Available Most of the cervical spine injuries in the pediatric population are typically seen in the upper cervical region. Unilateral cervical facet dislocation (UFD in subaxial region is a rare injury in pediatric population. In this paper, a rare case of delayed locked UFD in a 9-year-old boy with rare injury mechanism treated surgically is reported. Clinical and radiological findings were described. The patient with C6-7 UFD without neurologic deficit was underwent open reduction and internal fixation via anterior and posterior combined approaches. Significant improvement of pain and free motion in cervical spine was obtained. There was no complication during the follow up. Only three case reports presented about the lower cervical spine injury with UFD under the age of 10 were found in the literature.

  14. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  15. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    OpenAIRE

    Lokesh; Dayanand; Deepak; Hemanth

    2016-01-01

    INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articul...

  16. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  17. Supraglenoid tubercle fractures repair with transverse locking compression plates in 4 horses.

    Science.gov (United States)

    Ahern, B J; Bayliss, I P M; Zedler, S T; Getman, L M; Richardson, D W

    2017-05-01

    To report on a series of 4 horses with supraglenoid tubercle fractures repaired with locking compression plates. Case series. Four horses ranging in age from 6 weeks to 20 months and weighing from 121 to 425 kg with supraglenoid tubercle fractures of 1 day to 6 weeks in duration. Supraglenoid tubercle fractures were reduced and stabilized with transversely positioned locking compression plate(s) with and without additional tension band wiring. All fractures reached bony union. Two postoperative surgical site infections were managed with drainage and antibiotherapy. Three of the 4 horses continued onto athletic careers including flat racing, dressage, and hunter/jumper competition. The remaining horse was lame for a prolonged period, but was sound at 4 years. The application of one or two, transversely positioned LCPs should be considered for the repair of SGT fractures because of the relative ease of the technique, and its elimination of a biceps brachii tenotomy. All screws can be inserted in a lateral to medial direction without transection or drill penetration of the biceps brachii tendon. SGT fractures of various durations can be repaired in a wide range of horses with transversely positioned LCPs, and allow return to athletic function. © 2017 The American College of Veterinary Surgeons.

  18. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  19. Use of locking plates for fixation of the greater trochanter in patients with hip replacement

    Directory of Open Access Journals (Sweden)

    Allison K. Tetreault, BA

    2016-12-01

    Conclusions: Locking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge.

  20. The Dynamic Locking Blade Plate : innovation in the treatment of femoral neck fractures

    NARCIS (Netherlands)

    Roerdink, W.H.

    2011-01-01

    The scope of this thesis was to describe the design and development of the Dynamic Locking Blade Plate (DLBP), an improved internal fixation (IF) device for intracapsular hip fractures. This thesis focuses on intracapsular hip fractures since the results of current surgical treatment of this type of

  1. Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Jiang-Jun Zhou

    2017-01-01

    Full Text Available In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP and a locking compression plate (LCP. CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing.

  2. Functional Results of Unstable (Type 2 Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

    Directory of Open Access Journals (Sweden)

    Rajesh Govindasamy

    2017-11-01

    Full Text Available Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior locking plate.Methods: From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years 11 withunilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They wereevaluated at regular intervals with mean follow up of 14 months(12-18 months.Those with minimum one year followup were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder scoreand Quick DASH scores, rate of bone union, complications and earliest time for return to work.Results: All fractures union seen within 6-8 weeks (mean time: 7.1 weeks.All had good shoulder range of motion. Theaverage oxford shoulder and Quick DASH score were 46.2 and 6.5.There were no major complications in our studyviz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned towork within 3 months of postoperative period.Conclusion: Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent resultsin terms of bony union with rarely any complications and demonstrate promising results with this novel technique.

  3. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  4. [Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture].

    Science.gov (United States)

    Yan, Rongliang; Qu, Jiafu; Cao, Lihai; Liu, Hongda; Chen, Jianghua; Gao, Yan; Peng, Yi

    2018-05-01

    To summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture. Between January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score. All incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%. The procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

  5. EFFICACY OF CAGE PLACEMENT WITHOUT PLATE IN PATIENTS WITH CERVICAL MYELOPATHY WITH SINGLE-LEVEL AFFECTION

    Directory of Open Access Journals (Sweden)

    CARLOS ALBERTO ZUÑIGA-MAZÓN

    Full Text Available ABSTRACT Objective: To determine the efficacy of PEEK (Poly-ether-ether-ketone cage without plate for the treatment of single-level cervical spondylosis. Methods: Ten patients with cervical myelopathy data, with a single-level root condition, seen at the outpatient clinic of the Neurosurgery Service, operated in 2016, mean age 53 years, 6 (60% female, 4 (40% obese, 3 (30% smokers. The Cloward technique was used by anterior approach, discectomy, and PEEK cage placement. Results: At six months of surgery, 100% of the patients had increased intervertebral space, with a 100% reduction in osteophytes; only one patient had dysphagia, no patient had lesion of the adjacent segment and 10% had persistent root pathology. Cervical lordosis was observed in 90% of the patients and arthrodesis in 100% of the cases. Conclusions: Anterior approach arthrodesis using PEEK cage without cervical plate is effective as a treatment of cervical myelopathy in a single level.

  6. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  7. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  8. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  9. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate

  10. Initial outcome and efficacy of S3 proximal humerus locking plate in the treatment of proximal humerus fractures

    International Nuclear Information System (INIS)

    Zhang Zhiming; Zhu Xuesong; Bao Zhaohua; Yang Huilin

    2012-01-01

    Objective: to explore the initial outcome and efficacy of S 3 proximal humerus locking plate in the treatment of proximal humerus fractures. Methods: Twenty-two patients with proximal humerus fracture were treated with the S 3 proximal humerus locking plate. Most of the fractures were complex, two-part (n=4), three-part (n=11) and four-part (n=7) fractures according to the Neer classification of the proximal humerus fractures. Results: All patients were followed up for 3∼15 months. There were no complications related to the implant including loosening or breakage of the plate. Good and excellent results were documented in 17 patients fair results in 4 patients according the Neer scores of shoulder. Conclusion: New design concepts of S 3 proximal humerus plate provide the subchondral support and the internal fixation support. With the addition of the proper exercise of the shoulder joint, the outcomes would be satisfied. (authors)

  11. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  12. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    Science.gov (United States)

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  13. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    Science.gov (United States)

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  14. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  15. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    Science.gov (United States)

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les

  16. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  17. Locking device of a guiding ring on a plate including an aperture; application to guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Cauquelin, C.; Poitrenaud, P.

    1987-01-01

    To make easy to take to pieces a guide tube, by a simple tool, this device includes a guide ring. This guide ring aligned with an aperture in a plate has a tubular support fixed to the plate and coaxial with the aperture and lock the guide tube by rotation [fr

  18. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  19. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  20. SURGICAL MANAGEMENT OF TRAUMATIC MANUBRIO-STERNAL DISLOCATION WITH LOCKING COMPRESSION PLATE; A CASE REPORT AND REVIEW OF LITERATURE

    Directory of Open Access Journals (Sweden)

    FAREED AHMED SHAIKH

    2017-05-01

    Full Text Available Background: Manubriosternal joint dislocation as a result of trauma is rare with only few case reports published in literature. Materials that have been used for fixation of displaced manubriosternal joint are steel wires, polydioxanone ropes, and plates with screws. Case: We present a case of manubriosternal dislocation in which fixation was done with locking compression plate. This is a case of 32 years old lady with history of road traffic accident, car ran over her chest. She had bilateral lung contusions with multiple rib fractures on right side and manubriosternal joint dislocation of type-I. Patient was initially stabilized in high dependency unit, and once her contusions got better, she underwent fixation of her manubriosternal dislocation with locking compression plate. Post-operatively she remained pain free and was discharged home. Conclusion: This case is an important addition to literature regarding options that can be used for fixation of manubriosternal joint dislocation.

  1. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  2. Treatment of unstable fractures, dislocations and fracture-dislocations of the cervical spine with Senegas plate fixation

    NARCIS (Netherlands)

    Moerman, J.; Harth, A.; Trimpont, van I.; Uyttendaele, D.; Verdonk, R.; Claessens, H.A.; Verbeke, S.

    1994-01-01

    The results of the anterior approach to the cervical spine for the treatment of fractures and dislocations by arthrodesis and Senegas plate fixation are described. Twenty-two patients underwent a one- or two-level arthrodesis of the cervical spine. Their mean age was 42 years. The injuries were

  3. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  4. Biomechanics of far cortical locking.

    Science.gov (United States)

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  5. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  6. Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease.

    Science.gov (United States)

    Noh, Sung Hyun; Zhang, Ho Yeol

    2018-01-25

    We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease. We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 patients), or a titanium plate with a polyetheretherketone (PEEK) cage (71 patients). We conducted a retrospective study to compare the clinical and radiological results among the three groups. The length of the operation, intraoperative blood loss, and duration of hospitalization were significantly lower in the Perfect-C group than in the Zero-P and plate-with-cage groups (P Zero-P groups but was noted in 21 cases (30%) in the plate-with-cage group. The cephalad and caudal plate-to-disc distance (PDD) and the cephalad and caudal PDD/anterior body height (ABH) were significantly greater in the Perfect-C and Zero-P groups than in the plate-with-cage group (P Zero-P group, and in 15 cases (21%) in the plate-with-cage group. Fusion occurred in 37 cases (90%) in the Perfect-C group, in 31 cases (86%) in the Zero-P group, and in 68 cases (95%) in the plate-with-cage group. The Perfect-C, Zero-P, and plate-with-cage devices are effective for treating single-level cervical degenerative disc disease. However, the Perfect-C implant has many advantages over both the Zero-P implant and conventional plate-cage treatments. The Perfect-C implant was associated with shorter operation times and hospitalization durations, less blood loss, and lower subsidence rates compared with the Zero-P implant or the titanium plate with a PEEK cage.

  7. [Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation].

    Science.gov (United States)

    Sun, Yuanlin; Yang, Yunkang; Ge, Jianhua; Yang, Kun; Xiang, Feifan; Zhou, Ju; Liang, Jie

    2018-03-01

    To report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation. A new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B ( n =16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score ( P >0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score. The operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B ( P case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups ( P =1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B ( t= 2.270, P =0.031); but there was no significant difference in the Rockwood

  8. A technical case report on use of tubular retractors for anterior cervical spine surgery.

    Science.gov (United States)

    Kulkarni, Arvind G; Patel, Ankit; Ankith, N V

    2017-12-19

    The authors put-forth this technical report to establish the feasibility of performing an anterior cervical corpectomy and fusion (ACCF) and a two-level anterior cervical discectomy and fusion (ACDF) using a minimally invasive approach with tubular retractors. First case: cervical spondylotic myelopathy secondary to a large postero-inferiorly migrated disc treated with corpectomy and reconstruction with a mesh cage and locking plate. Second case: cervical disc herniation with radiculopathy treated with a two-level ACDF. Both cases were operated with minimally invasive approach with tubular retractor using a single incision. Technical aspects and clinical outcomes have been reported. No intra or post-operative complications were encountered. Intra-operative blood loss was negligible. The patients had a cosmetic scar on healing. Standard procedure of placement of tubular retractors is sufficient for adequate surgical exposure with minimal invasiveness. Minimally invasive approach to anterior cervical spine with tubular retractors is feasible. This is the first report on use of minimally invasive approach for ACCF and two-level ACDF.

  9. In vitro evaluation of stiffness and load sharing in a two-level corpectomy: comparison of static and dynamic cervical plates.

    Science.gov (United States)

    Fogel, Guy R; Li, Zhenyu; Liu, Weiqiang; Liao, Zhenhua; Wu, Jia; Zhou, Wenyu

    2010-05-01

    Anterior cervical plating has been accepted in corpectomy and fusion of the cervical spine. Constrained plates were criticized for stress shielding that may lead to subsidence and pseudarthrosis. A dynamic plate allows load sharing as the graft subsides. Ideally, the dynamic plate design should maintain adequate stiffness of the construct while providing a reasonable load sharing with the strut graft. The purpose of the study was to compare dynamic and static plate kinematics with graft subsidence. The study designed was an in vitro biomechanical study in a porcine cervical spine model. Twelve spines were initially tested in intact condition with 20-N axial load in 15 degrees of flexion and extension range of motion (ROM). Then, a two-level corpectomy was created in all specimens with spines randomized to receive either a static or dynamic plate. The spines were retested under identical conditions with optimal length and undersized graft. Range of motion and graft loading were analyzed with a one-way analysis of variance (p<.05). Both plates significantly limited ROM compared with the intact spine in both graft length conditions. In extension graft, load was significantly higher (p=.001) in the static plate with optimal length, and in flexion, there was a significant loss of graft load (p=.0004). In flexion, the dynamic plate with undersized graft demonstrated significantly more load sustained (p=.0004). Both plates reasonably limited the ROM of the corpectomy. The static plate had significantly higher graft loads in extension and significant loss of graft load in flexion, whereas the dynamic plate maintained a reasonable graft load in ROM even when graft contact was imperfect. Copyright 2010 Elsevier Inc. All rights reserved.

  10. Internal Fixation of Cervical Fractures in Three Horses.

    Science.gov (United States)

    Rossignol, Fabrice; Brandenberger, Olivier; Mespoulhes-Rivière, Céline

    2016-01-01

    To describe the surgical treatment outcome of cervical fractures in 3 horses. Case report. Three client-owned horses with cervical vertebral fractures. Three horses were refered for neck stiffness, pain, and ataxia after a cervical trauma because of a fall. Radiographic examination showed an oblique displaced fracture of the caudal aspect of the body of the second cervical vertebra (C2) in horse 1, an oblique displaced fracture of the caudal aspect of C4 involving the disc between C4 and C5 in horse 2, and a displaced transverse fracture of the body of the axis (C2) extending to the lateral arches and involving the vertebral canal in horse 3. In horse 1, the fracture was reduced and stabilized using a 14-hole narrow DCP plate, applied ventrally, and fixed with cancellous screws. A cervical fusion was performed. In horses 2 and 3, fracture fixation was performed using a 5-hole narrow LCP and 5 mm locking screws. All horses showed improvement and returned to full activity. The fracture healed in all horses. Internal fixation of cervical fracture in these horses was associated with minimal complications, and was associated with healing and a highly functional outcome in all horses. The LCP was preferred and would be recommended for ventral stabilization of selected cases of vertebral fractures. © Copyright 2015 by The American College of Veterinary Surgeons.

  11. The Use of the String of Pearls Locking Plate System in the Stabilisation of a Comminuted Calcaneal Fracture in a Giant Breed Dog

    Directory of Open Access Journals (Sweden)

    A. B. Scrimgeour

    2011-01-01

    Full Text Available An eight-year-old male Pyrenean mountain dog was presented with a comminuted fracture of the right calcaneus following motor vehicle trauma. The fracture was stabilised with a plate-rod construct, using the String of Pearls locking plate system and an intramedullary pin. Healing was uncomplicated.

  12. Distraction osteogenesis using combined locking plate and Ilizarov fixator in the treatment of bone defect: A report of 2 cases

    Directory of Open Access Journals (Sweden)

    John Mukhopadhaya

    2017-01-01

    Full Text Available Distraction osteogenesis and bone transport has been used to reconstruct bone loss defect by allowing new bone to form in the gap. Plate-guided bone transport has been successfully described in literature to treat bone loss defect in the femur, tibia, and mandible. This study reports two cases of fracture of femur with segmental bone loss treated with locking plate fixation and bone transport with Ilizarov ring fixator. At the time of docking, when the transport segment is compressed with bone fragment, the bone fragment is fixed with additional locking or nonlocking screws through the plate. The bone defect size was 7 cm in case 1 and 8 cm in case 2 and the external fixation indexes were 12.7 days/cm and 14 days/cm. No shortening was present in either of our cases. The average radiographic consolidation index was 37 days/cm. Both cases achieved infection-free bone segment regeneration and satisfactorily functional outcome. This technique reduces the duration of external fixation during the consolidation phase, allows correction of length and alignment and provides earlier rehabilitation.

  13. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    Science.gov (United States)

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  15. Adjacent segment pathology following anterior decompression and fusion using cage and plate for the treatment of degenerative cervical spinal diseases.

    Science.gov (United States)

    Song, Kyung-Jin; Choi, Byung-Wan; Kim, Jong-Kil

    2014-12-01

    Retrospective study. To analyze the incidence and prevalence of clinical adjacent segment pathology (CASP) following anterior decompression and fusion with cage and plate augmentation for degenerative cervical diseases. No long-term data on the use of cage and plate augmentation have been reported. The study population consisted of 231 patients who underwent anterior cervical discectomy and fusion (ACDF) with cage and plate for degenerative cervical spinal disease. The incidence and prevalence of CASP was determined by using the Kaplan-Meier survival analysis. To analyze the factors that influence CASP, data on preoperative and postoperative sagittal alignment, spinal canal diameter, the distance between the plate and adjacent disc, extent of fusion level, and the presence or absence of adjacent segment degenerative changes by imaging studies were evaluated. CASP occurred in 15 of the cases, of which 9 required additional surgery. At 8-year follow-up, the average yearly incidence was 1.1%. The rate of disease-free survival based on Kaplan-Meier survival analysis was 93.6% at 5 years and 90.2% at 8 years. No statistically significant differences in CASP incidence based on radiological analysis were observed. Significantly high incidence of CASP was observed in the presence of increased adjacent segment degenerative changes (pdegenerative cervical disease is associated with a lower incidence in CSAP by 1.1% per year, and the extent of preoperative adjacent segment degenerative changes has been shown as a risk factor for CASP.

  16. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  17. Application of Minimally Invasive Treatment of Locking Compression Plate in Schatzker Ⅰ-Ⅲ Tibial Plateau Fracture

    OpenAIRE

    Guohui Zhao

    2014-01-01

    Objective: To investigate the clinical effect of minimally invasive treatment of locking compression plate (LCP) in Schatzker Ⅰ-Ⅲ tibial plateau fracture. Methods: Thirty-eight patients with Schatzker Ⅰ-Ⅲ tibial plateau fracture in our hospital were given minimally invasive treatment of LCP, and the artificial bone was transplanted to the depressed bone. Adverse responses, wound healing time and clinical efficacy were observed. Results: All patients were followed-up for 14- 20 months, and the...

  18. Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2018-04-01

    Full Text Available Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP and external fixation (EF are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two interventions by this meta-analysis. Methods: We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study. Results: Seven studies included 162 patients (LP group and 190 patients (EF group. We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50, p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23, p = 0.05; WMD = 0.05, 95% CI (−0.99, 1.09, p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (−6.88, 26.96, p = 0.24; WMD = 12.53, 95% CI (−9.99, 35.06, p = 0.28]. Conclusion

  19. Plate rotations, fault slip rates, fault locking, and distributed deformation in northern Central America from 1999-2017 GPS observations

    Science.gov (United States)

    Ellis, A. P.; DeMets, C.; Briole, P.; Cosenza, B.; Flores, O.; Guzman-Speziale, M.; Hernandez, D.; Kostoglodov, V.; La Femina, P. C.; Lord, N. E.; Lasserre, C.; Lyon-Caen, H.; McCaffrey, R.; Molina, E.; Rodriguez, M.; Staller, A.; Rogers, R.

    2017-12-01

    We describe plate rotations, fault slip rates, and fault locking estimated from a new 100-station GPS velocity field at the western end of the Caribbean plate, where the Motagua-Polochic fault zone, Middle America trench, and Central America volcanic arc faults converge. In northern Central America, fifty-one upper-plate earthquakes caused approximately 40,000 fatalities since 1900. The proximity of main population centers to these destructive earthquakes and the resulting loss of human life provide strong motivation for studying the present-day tectonics of Central America. Plate rotations, fault slip rates, and deformation are quantified via a two-stage inversion of daily GPS position time series using TDEFNODE modeling software. In the first stage, transient deformation associated with three M>7 earthquakes in 2009 and 2012 is estimated and removed from the GPS position time series. In Stage 2, linear velocities determined from the corrected GPS time series are inverted to estimate deformation within the western Caribbean plate, slip rates along the Motagua-Polochic faults and faults in the Central America volcanic arc, and the gradient of extension in the Honduras-Guatemala wedge. Major outcomes of the second inversion include the following: (1) Confirmation that slip rates on the Motagua fault decrease from 17-18 mm/yr at its eastern end to 0-5 mm/yr at its western end, in accord with previous results. (2) A transition from moderate subduction zone locking offshore from southern Mexico and parts of southern Guatemala to weak or zero coupling offshore from El Salvador and parts of Nicaragua along the Middle America trench. (3) Evidence for significant east-west extension in southern Guatemala between the Motagua fault and volcanic arc. Our study also shows evidence for creep on the eastern Motagua fault that diminishes westward along the North America-Caribbean plate boundary.

  20. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    Science.gov (United States)

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  1. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    Science.gov (United States)

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  2. Close Intramedullary Interlocking Nailing Versus Locking Compression Plating In the Treatment of Closed Fracture Shaft of the Tibia.

    Science.gov (United States)

    Kundu, I K; Datta, N K; Chowdhury, A Z; Das, K P; Tarik, M M; Faisal, M A

    2016-07-01

    Fracture of tibial shaft is the commonest site of long bone fractures due to its superficial location involving young or middle-age people. Proper management is an important issue regarding the future effective movements. In this study patients were grouped in closed Intra medullary interlocking nailing and locking compression plating. Post-operative follow up at 2 weeks, 6 weeks, 12 weeks and 3 months thereafter up to 6 months were done. Each of the patients was evaluated clinically and radiologically by tucker criteria of Tuker et al. Patients were assessed for pain on full weight bearing and kneeling, shortening and range of motion of knee and ankle joints. Radiological assessment for union of fracture, alignment of fracture and angulations and position of nail and screws and infection were observed during follow up. A total number of 32 patients were selected but only 27 patients were available for follow up for a period of 6 months. They were grouped into Group A, consisting of 15 patients who took the treatment in the form of closed intramedullary interlocking nailing and Group B, consisting of 12 patients those underwent ORIF with locking compression plating. In both of the groups Motor Vehicle Accident was the main mechanism of trauma. Fracture involving the middle 3rd of the tibia is common in both the groups. During post-operative follow up, four patients in Group A complained anterior knee pain, one patient in Group B had superficial infection, most of the patients had no restriction of movement in the ankle and knee joints and a single patient in Group B showed 1.5cm shortening of the lower limb. Period of hospital stay and fracture union time were less in Group A, which was statistically significant. Both groups showed excellent result with minimum complications. So this study permits to conclude that close IM interlocking nailing and open reduction and internal fixation by locking compression plating is equally effective for the management of close

  3. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates.

    Science.gov (United States)

    Adam, P; Bonnomet, F; Ehlinger, M

    2012-09-01

    Intramedullary nailing is a common method of treating tibial shaft fractures. However, precise control of reduction at the proximal and distal quarters is difficult to achieve. The purpose of this study was to assess the results of plating using locking screws and the feasibility of a minimally-invasive approach. All patients with tibial shaft fracture treated by means of locking plates from January 2004 to October 2006. Thirty-two fractures were treated in 32 patients with a mean age of 43.8 years. Internal fixation with a locking plate and screw construct, using a minimally-invasive or standard approach. Surgical approach, time to weight bearing, complications and their type, time to bone union, alignment in the frontal and sagittal planes on anteroposterior and lateral radiographs. The minimally-invasive approach was performed in 28 cases and immediate full weight bearing allowed in 25 cases. At a mean follow-up of 27 months, two patients had died and two patients were lost to follow-up. The mean time to bone union was 9.1 weeks. Four cases had a complicated course: one infection, one compartment syndrome, one hardware breakage and one pseudarthrosis. Six cases ended up with valgus malunion exceeding 5° in the frontal plane, already present at the time of surgery. Where a minimally-invasive approach can be performed, immediate pain-free weight bearing can be allowed without further displacement at follow-up. The observed rate of malunion underlines the need for adequate reduction and shows that the rationale for success does not solely depend on the plate anatomic design but also on the skills of the operating surgeon. Level I university regional hospital Cohort study. Copyright © 2012. Published by Elsevier Masson SAS.

  4. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  5. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  6. Technical Errors May Affect Accuracy of Torque Limiter in Locking Plate Osteosynthesis.

    Science.gov (United States)

    Savin, David D; Lee, Simon; Bohnenkamp, Frank C; Pastor, Andrew; Garapati, Rajeev; Goldberg, Benjamin A

    2016-01-01

    In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.

  7. Reusable locking tube in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a reconstitutable fuel assembly including a top nozzle with an adapter plate having an interior wall forming at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having an outer socket formed by a circumferential groove defined in the adapter plate passageway wall and opening into the passageway and an inner socket formed by a circumferential bulge and at least one longitudinal slot defined in the upper end portion of the guide thimble. The circumferential bulge is capable of seating within the circumferential groove, an improved reusable tube for releasably locking the inner socket of the guide thimble upper end portion in locking engagement within the outer socket of the adapter plate passageway when the circumferential bulge is seated within the circumferential groove. The reusable tube comprises: (a) an elongated hollow tubular body capable of insertion within the adapter plate passageway and guide thimble upper end portion to a locking position therein such that the circumferential bulge of the inner socket is maintained seated in the locking engagement with the circumferential groove of the outer socket; and (b) at least a pair of dimples performed on the exterior of the tubular body prior to insertion of the body in the guide thimble upper end portion and to the locking position, the dimples being performed and configured to increase the thickness of the tubular body in relation to the remainder of the tubular body. The dimples are substantially resisting resilient yielding in relation to the remainder of the tubular body

  8. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    Science.gov (United States)

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  9. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  10. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  11. Surgical treatment for old subaxial cervical dislocation with bilateral locked facets in a 3-year-old girl: A case report.

    Science.gov (United States)

    Li, Cheng; Li, Lei; Duan, Jingzhu; Zhang, Lijun; Liu, Zhenjiang

    2018-05-01

    This study aimed to describe the case of a 3-year-old girl with old bilateral facet dislocation on cervical vertebrae 6 and 7, who had spinal cord transection, received surgical treatment, and achieved a relative satisfactory therapeutic effect. A 3-year-old girl was urgently transferred to the hospital after a car accident. DIAGNOSES:: she was diagnosed with splenic rupture, intracranial hemorrhage, cervical dislocation, spinal transection, and Monteggia fracture of the left upper limb. The girl underwent emergency splenectomy and was transferred to the intensive care unit of the hospital 15 days later. One-stage anterior-posterior approach surgery (anterior discectomy, posterior laminectomy, and pedicle screw fixation) was performed when the patient stabilized after 45-day symptomatic treatment. The operation was uneventful. The reduction of lower cervical dislocation was satisfactory, with sufficient spinal cord decompression. The internal fixation position was good, and the spinal sequence was well restored. The girl was discharged 2 weeks later after the operation and followed up for 2 years. The major nerve function of both upper limbs was recovered, with no obvious retardation of the growth of immature spine. A satisfactory therapeutic effect was achieved for a pediatric old subaxial cervical dislocation with bilateral locked facets using anterior discectomy, posterior laminectomy, and pedicle screw fixation. The posterior pedicle screw fixation provided a good three-dimensional stability of the spine, with reduced risk and complications caused by anterior internal fixation. The growth of immature spine was not obviously affected during the 2-year follow-up.

  12. Reusable locking tube insertion and removal fixture and method in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a locking tube insertion and removal fixture for use with a reconstitutable fuel assembly. The process includes a top nozzle with an adapter plate having at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having a hollow locking tube insertable and removable into and from a locking position in the upper end portion of the guide thimble for releasably locking the upper end portion of the guide thimble within the passageway of the top nozzle and adapter plate

  13. Locking of metacarpophalangeal joints in a patient with acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Y.; Tanaka, N.; Isoya, Eiji [Dept. of Orthopaedic Surgery, Soseikai General Hospital, Kyoto (Japan)

    1999-11-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  14. Locking of metacarpophalangeal joints in a patient with acromegaly

    International Nuclear Information System (INIS)

    Tani, Y.; Tanaka, N.; Isoya, Eiji

    1999-01-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  15. Comparison of the incidence of patient-reported post-operative dysphagia between ACDF with a traditional anterior plate and artificial cervical disc replacement.

    Science.gov (United States)

    Yang, Yi; Ma, Litai; Liu, Hao; Liu, Yilian; Hong, Ying; Wang, Beiyu; Ding, Chen; Deng, Yuxiao; Song, Yueming; Liu, Limin

    2016-09-01

    Compared with anterior cervical discectomy and fusion (ACDF), cervical disc replacement (CDR) has provided satisfactory clinical results. The incidence of post-operative dysphagia between ACDF with a traditional anterior plate and CDR remains controversial. Considering the limited studies and knowledge in this area, a retrospective study focusing on post-operative dysphagia was conducted. The Bazaz grading system was used to assess the severity of dysphagia at post-operative intervals including 1 week, 1 month, 3 months, 6 months, 12 months and 24 months respectively. The Chi-square test, Student t-test, Mann-Whitney U tests and Ordinal Logistic regression were used for data analysis when appropriate. Statistical significance was accepted at a probability value of dysphagia in the CDR and plate group were 36.58% and 60.43% at one week, 29.27% and 38.85% at one month, 21.95% and 31.65% at three months, 6.83% and 17.99% at six months, 5.85% and 14.39% at 12 months, and 4.39% and 10.07% at the final follow-up respectively (All Pdysphagia (all Pdysphagia. Female patients, two-level surgery, C4/5 surgery and anterior cervical plating were associated with a higher incidence of dysphagia. Future prospective, randomized, controlled studies are needed to further validate these findings. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Compartment syndrome like picture in metaphyseal comminuted fracture of tibia treated by locking plate due to tight closure

    Directory of Open Access Journals (Sweden)

    Prafulla Herode

    2013-01-01

    Full Text Available A 22-year-old male came to casualty on 5 th May 2012 after a fall from motorcycle. He complained of excruciating pain and swelling over right knee. There was an open wound of 7 × 2 cm over supra-patellar region and diffuse swelling over knee joint with severe tenderness over proximal aspect of right tibia. X-ray showed intra-articular fracture of proximal tibia extending to diaphysis classified as type 6 by Schatzker classification for proximal tibia, with fibula shaft transverse fracture. The skin over the fracture was contused. Debridement with primary wound closure was done in emergency. Skeletal traction was applied through a lower tibial Steinman pin. Patient was operated after 15 days when wound healed and swelling subsided. Locking plate was applied on medial aspect using Minimally invasive percutaneous plate osteosysthesis (MIPPO technique. Post-operatively over 4 hours patient developed severe pain and swelling in operated leg which mimicked compartment syndrome. Suture removal was done immediately in the ward from the distal aspect, which relieved the symptoms but lead to exposure of the plate. A rotational flap was done to cover the plate in coordination with a plastic surgeon on the next day.

  17. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.

    Science.gov (United States)

    Gaudelli, Cinzia; Ménard, Jérémie; Mutch, Jennifer; Laflamme, G-Yves; Petit, Yvan; Rouleau, Dominique M

    2014-11-01

    This paper aims to determine the strongest fixation method for split type greater tuberosity fractures of the proximal humerus by testing and comparing three fixation methods: a tension band with No. 2 wire suture, a double-row suture bridge with suture anchors, and a manually contoured calcaneal locking plate. Each method was tested on eight porcine humeri. A osteotomy of the greater tuberosity was performed 50° to the humeral shaft and then fixed according to one of three methods. The humeri were then placed in a testing apparatus and tension was applied along the supraspinatus tendon using a thermoelectric cooling clamp. The load required to produce 3mm and 5mm of displacement, as well as complete failure, was recorded using an axial load cell. The average load required to produce 3mm and 5mm of displacement was 658N and 1112N for the locking plate, 199N and 247N for the double row, and 75N and 105N for the tension band. The difference between the three groups was significant (Prow (456N) and tension band (279N) (Prow (71N/mm) and tension band (33N/mm) (Pbiomechanical fixation for split type greater tuberosity fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Comparative effectiveness of different types of cervical laminoplasty.

    Science.gov (United States)

    Heller, John G; Raich, Annie L; Dettori, Joseph R; Riew, K Daniel

    2013-10-01

    Study Design Systematic review. Study Rationale Numerous cervical laminoplasty techniques have been described but there are few studies that have compared these to determine the superiority of one over another. Clinical Questions The clinical questions include key question (KQ)1: In adults with cervical myelopathy from ossification of the posterior longitudinal ligament (OPLL) or spondylosis, what is the comparative effectiveness of open door cervical laminoplasty versus French door cervical laminoplasty? KQ2: In adults with cervical myelopathy from OPLL or spondylosis, are postoperative complications, including pain and infection, different for the use of miniplates versus the use of no plates following laminoplasty? KQ3: Do these results vary based on early active postoperative cervical motion? Materials and Methods A systematic review of the English-language literature was undertaken for articles published between 1970 and March 11, 2013. Electronic databases and reference lists of key articles were searched to identify studies evaluating (1) open door cervical laminoplasty and French door cervical laminoplasty and (2) the use of miniplates or no plates in cervical laminoplasty for the treatment of cervical spondylotic myelopathy or OPLL in adults. Studies involving traumatic onset, cervical fracture, infection, deformity, or neoplasms were excluded, as were noncomparative studies. Two independent reviewers (A.L.R., J.R.D.) assessed the level of evidence quality using the Grades of Recommendations Assessment, Development and Evaluation system, and disagreements were resolved by consensus. Results We identified three studies (one of class of evidence [CoE] II and two of CoE III) meeting our inclusion criteria comparing open door cervical laminoplasty with French door laminoplasty and two studies (one CoE II and one CoE III) comparing the use of miniplates with no plates. Data from one randomized controlled trial (RCT) and two retrospective cohort

  20. Investigation of vertebral ''end plate sclerosis''

    International Nuclear Information System (INIS)

    Lee, S.W.; Mathie, A.G.; Jackson, J.E.; Hughes, S.P.F.

    2001-01-01

    To evaluate the association between vertebral ''end plate sclerosis'' and neck pain. A retrospective study was carried out of lateral cervical spine radiographs with a Picture Archive and Communication System (PACS). Two hundred patients' files were randomly assessed, comprising four equal groups, A to D. The mean ages of the patients were 62±7.4 years, 61±7.5 years, 40±5.6 years and 23±5.6 years respectively. In group A, all patients had symptoms of neck pain and a radiographic diagnosis of ''end plate sclerosis'' of the cervical spine. In groups B to D, asymptomatic patients were recruited and their age groups were 50-69, 30-49 and 10-29 years respectively. Using the PACS, the radiographic density and the sagittal diameter, thickness and area of the end plates at the C5 level were measured. Results and conclusions: No significant differences were found in the radiographic density of the end plates either between the symptomatic and asymptomatic groups (groups A and B), or between different age groups (groups B, C and D). A significant increase in end plate area and thickness was found, however, in both group B (P<0.005) and group C (P<0.01) in comparison with group D. This indicates that the extent of end plate sclerosis increases with age. Our results suggest that the radiographic density of cervical vertebral end plates correlates neither with neck pain nor with increasing age. The radiological sign of ''end plate sclerosis'' may be over-reported, further limiting its value in the assessment of patients with cervical spondylosis. (orig.)

  1. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review

    DEFF Research Database (Denmark)

    Brorson, Stig; Rasmussen, Jeppe Vejlgaard; Frich, Lars Henrik

    2012-01-01

    stable plates in AO/OTA Type C fractures of the proximal humerus. METHODS: We conducted an iterative search in PubMed, Embase, Cochrane Library, Web of Science, Cinahl, and PEDro in all languages from 1999 to November 2010. Eligible studies should study the outcome for Type C fractures after primary...... according to study type and synthesised qualitatively. No randomised clinical trials were identified. Two comparative, observational studies reported a mean CS of 71 (relative to contralateral shoulder) and 75 (non-adjusted Constant Score) for Type C fractures. For all studies mean non-adjusted CS ranged......INTRODUCTION: Locking plate osteosynthesis of proximal humeral fractures are widely recommended and used, even in complex intraarticular fracture patterns such as AO/OTA Type C fractures. We systematically reviewed clinical studies assessing the benefits and harms of osteosynthesis with angle...

  2. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  3. Fixation of supraglenoid tubercle fractures using distal femoral locking plates in three Warmblood horses.

    Science.gov (United States)

    Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S

    2016-05-18

    Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.

  4. [Results to 4-year follow-up of the treatment of the cervical stenosis by corpectomy, titanium mesh cage and anterior plate fixation].

    Science.gov (United States)

    Reyes Sánchez, Alejandro Antonio; Gameros Castañeda, Luis Alberto; Obil Chavarría, Claudia; Alpizar Aguirre, Armando; Zárate Kalfópulos, Barón; Rosales-Olivares, Luis Miguel

    Cervical spondylotic myelopathy is caused by cervical stenosis. Several techniques have been described for the treatment of multilevel disease, such as the anterior corpectomy with titanium mesh cage and anterior cervical plate placement, which has the advantage of performing a wider decompression and using the same bone as graft. However, it has caused controversy since the collapse of the mesh cage continues being a major limitation of this procedure. A prospective 4-year follow-up study was conducted in 7 patients diagnosed with cervical stenosis, who were treated surgically by one level corpectomy with titanium mesh cage and anterior cervical plate placement, evaluating them by radiographs and clinical scales. 7 patients, 5 women and 2 males were studied. The most common level was C5 corpectomy (n=4). The Neck Disability Index (NDI) preoperative average was 30.01±24.32 and 4-year postoperative 16.90±32.05, with p=0.801. The preoperative and 4-year postoperative Nürick was 3.28± 48 and 3.14±1.21 respectively, with p=0.766. Preoperative lordosis was 14.42±8.03 and 4-year postoperative 17±11.67 degrees, with p=0.660. The immediate postoperative and 4-year postoperative subsidence was 2.69±2.8 and 6.11±1.61 millimeters respectively, with p=0.0001. Despite the small sample, the subsidence of the mesh cage is common in this procedure. No statistically significant changes were observed in the lordosis or Nürick scale and NDI. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Treatment of type 2 and 4 olecranon fractures with locking compression plate (LCP) osteosynthesis in horses: a prospective study (2002-2008)

    OpenAIRE

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fürst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection an...

  6. Zero-profile anchored cage reduces risk of postoperative dysphagia compared with cage with plate fixation after anterior cervical discectomy and fusion.

    Science.gov (United States)

    Xiao, ShanWen; Liang, ZhuDe; Wei, Wu; Ning, JinPei

    2017-04-01

    To compare the rate of postoperative dysphagia between zero-profile anchored cage fixation (ZPC group) and cage with plate fixation (CP group) after anterior cervical discectomy and fusion (ACDF). A meta-analysis of cohort studies between zero-profile anchored cage and conventional cage with plate fixation after ACDF for the treatment of cervical diseases from 2008 to May 2016. An extensive search of studies was performed in PubMed, Medline, Embase, Cochrane library and Google Scholar. Dysphagia rate was extracted. Data analysis was conducted with RevMan 5.2. Sixteen trials involving 1066 patients were included in this meta-analysis. The results suggested that the ZPC group were associated with lower incidences of dysphagia than the CP group at postoperative immediately, 2 weeks, 2, 3, 6 and 12 months. In subgroup analysis, although significant differences were only found in the mild dysphagia at 3 and 6 months postoperatively and in the moderate dysphagia at 2 weeks after surgery; the ZPC group had a lower rate of postoperative dysphagia than the CCP group in short, medium and long term follow-up periods. Zero-profile anchored cage had a lower risk of postoperative dysphagia than cage with plate.

  7. Is there a difference in range of motion, neck pain, and outcomes in patients with ossification of posterior longitudinal ligament versus those with cervical spondylosis, treated with plated laminoplasty?

    Science.gov (United States)

    Fujimori, Takahito; Le, Hai; Ziewacz, John E; Chou, Dean; Mummaneni, Praveen V

    2013-07-01

    There are little data on the effects of plated, or plate-only, open-door laminoplasty on cervical range of motion (ROM), neck pain, and clinical outcomes. The purpose of this study was to compare ROM after a plated laminoplasty in patients with ossification of posterior longitudinal ligament (OPLL) versus those with cervical spondylotic myelopathy (CSM) and to correlate ROM with postoperative neck pain and neurological outcomes. The authors retrospectively compared patients with a diagnosis of cervical stenosis due to either OPLL or CSM who had been treated with plated laminoplasty in the period from 2007 to 2012 at the University of California, San Francisco. Clinical outcomes were measured using the modified Japanese Orthopaedic Association (mJOA) scale and neck visual analog scale (VAS). Radiographic outcomes included assessment of changes in the C2-7 Cobb angle at flexion and extension, ROM at C2-7, and ROM of proximal and distal segments adjacent to the plated lamina. Sixty patients (40 men and 20 women) with an average age of 63.1 ± 10.9 years were included in the study. Forty-one patients had degenerative CSM and 19 patients had OPLL. The mean follow-up period was 20.9 ± 13.1 months. The mean mJOA score significantly improved in both the CSM and the OPLL groups (12.8 to 14.5, p cervical ROM, especially in the extension angle. Among patients who have undergone laminoplasty, those with OPLL lose more ROM than do those with CSM. No correlation was observed between neck pain and ROM in either group. Neither group had a change in neck pain that reached the MCID following laminoplasty. Both groups improved in neurological function and outcomes.

  8. Usefulness of polyetheretherketone (PEEK) cage with plate augmentation for anterior arthrodesis in traumatic cervical spine injury.

    Science.gov (United States)

    Song, Kyung-Jin; Choi, Byung-Wan; Kim, Gyu-Hyung; Song, Ji-Hun

    2010-01-01

    Even though many clinical reports about cages have been documented in patients with degenerative disorders, reports were scarce for traumatic injury cases, and those cases using metal cages were restricted to only one-level injury. To evaluate the usefulness of polyetheretherketone (PEEK) cage and plate construction in anterior interbody fusions (AIF) for traumatic cervical spine injuries by analyzing radiographic changes and clinical outcomes. Retrospective study. Fifty-eight patients (91 levels) underwent cage and plate construction for treatment of traumatic cervical spine injury. The fusion rate, fusion time, changes of Cobb angle, subsidence rate, and adjacent level changes were assessed as a radiographic outcome. Clinical analysis includes the recovery rate on the American Spinal Injury Association (ASIA) impairment scale and the presence of the complications. We evaluated 58 patients (91 levels) who underwent surgery and had at least 24 months in follow-up study. Radiographic evaluation included the assessment of interbody fusion rate, fusion time, changes of Cobb angle, subsidence rate, and adjacent level changes. Clinical assessment was done by analyzing recovery state of ASIA impairment scale from preoperative period to the last follow-up and by evaluating complications. Fifty-four cases showed bony fusion within 3 months after the surgery. The mean Cobb angle between the vertebral bodies was 2.54 degrees before operation, 9.13 degrees after operation, and 8.39 degrees at the latest follow-up. The mean intervertebral disc height was increased by 3.01 mm after the operation, but the mean height was 2.17 mm shorter at the last follow-up than after postoperation. In terms of clinical results, five Grade A cases and one Grade B case as assessed by the ASIA impairment scale were unchanged until the last follow-up. Twenty-three cases of Grade C, 16 cases of Grade D, and 13 cases of Grade E improved to seven cases, 26 cases, and 19 cases, respectively. Three

  9. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  10. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  11. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    Science.gov (United States)

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  12. Locking plate and fibular strut-graft augmentation in the reconstruction of unicameral bone cyst of proximal femur in the paediatric population.

    Science.gov (United States)

    Jamshidi, Khodamorad; Mirkazemi, Masoud; Izanloo, Azra; Mirzaei, Alireza

    2018-01-01

    Several therapeutic strategies have been used for managing unicameral bone cyst (UBC) of the proximal femur. However, there is insufficient evidence to support one treatment over another, and the optimal treatment is controversial. This study aims at describing our experience with surgical reconstruction of paediatric UBCs of the proximal femur using a proximal locking plate and fibular strut allograft. In total, 14 consecutive paediatric patients with Dormans types IB (four cases) and IIB (10 cases) UBC were assessed. Mean patient age was 8.6 ± 2.3 years, and mean follow-up period was 41.7 ± 29.8 months. Six patients (42.8%) were referred with a pathologic fracture. Clinical/radiological outcome and complication rates were evaluated at the final follow-up session. No cysts were Capanna's class III (recurrence) or IV (no response). Complete healing (Capanna's class I) was seen in ten cysts, while four other cysts healed with residual radiolucent areas (Capanna's class II). Mean healing period was 14.1 ± 5.1 (9-24 months). One patient had superficial infection, one heterotopic ossification, and one mild coxa vara, and mean Musculoskeletal Tumor Society (MSTS) score was 99.5%. According to our results, locking plate and fibular strut graft in Dormans classification types IB and IIB results in a favorable outcome in managing UBC of the proximal femur in the paediatric population.

  13. [Subsidence and its effects on the anterior plate stabilization in the course of cervical interbody spondylodesis. Part II. Clinical evaluation. Study design].

    Science.gov (United States)

    Hakało, Jerzy; Wroński, Jerzy

    2003-01-01

    Subsidence is a common phenomenon in the process of interbody fusion. The paper presents a retrospective clinical and radiological evaluation of subsidence in a group of 23 patients after cervical corpectomy with mesh cage and plate stabilization. Subsidence magnitude and its impact on the stabilizing system and on the clinical and radiological outcome were estimated. The mesh cage and cervical plate stabilization was preformed after one- (20 cases) or two-level (3 cases) corpectomy. The patients' mean age was 35 years (age range 18-72); 9 patients were aged over 50. Indications to corpectomy were: neurological impairment due to burst body fractures in 14 cases, multilevel spondylosis in 5, and OPLL in 2 patients. One patient had a kidney cancer metastasis. The mean follow-up period was 17 months (range 12-28 mo.). The patients' clinical status was evaluated using the ASIA scale in the post-traumatic group, and the Odom criteria in spondylotic cases. In all the cases pain severity was estimated by the VAS scale. Magnitude of subsidence was measured on consecutive lateral x-rays during the follow-up. Bone fusion was confirmed after 3 months in lateral flexion-extension x-rays. Changes in the local and general cervical lordosis were evaluated during the follow-up. A 72-year-old patient died after 6 weeks due to causes unrelated to the surgery. In all the remaining patients bone fusion was attained. There were no cases of the clinical status deterioration during the follow-up. Subsidence of over 1 mm was found in 19 patients (86.4%). The mean value of subsidence was 2.2 mm, but in a group of older patients (aged over 50) it amounted to 2.8 mm. In 4 cases (18.1%) with hardware complications, i.e. a screw breakage or slipping, the mean subsidence magnitude was 4.3 mm. Local and general cervical lordosis were maintained during the follow-up period, even in the group with excessive subsidence. The screw breakage site was invariably the round hole of the plate. The

  14. Application of Minimally Invasive Treatment of Locking Compression Plate in Schatzker Ⅰ-Ⅲ Tibial Plateau Fracture

    Directory of Open Access Journals (Sweden)

    Guohui Zhao

    2014-06-01

    Full Text Available Objective: To investigate the clinical effect of minimally invasive treatment of locking compression plate (LCP in Schatzker Ⅰ-Ⅲ tibial plateau fracture. Methods: Thirty-eight patients with Schatzker Ⅰ-Ⅲ tibial plateau fracture in our hospital were given minimally invasive treatment of LCP, and the artificial bone was transplanted to the depressed bone. Adverse responses, wound healing time and clinical efficacy were observed. Results: All patients were followed-up for 14- 20 months, and the mean duration was 16 months. Within 1 week after operation, 1 patient suffered from short-term rejection reaction to artificial bone, but he healed after corresponding measures were taken. There were no complications like skin necrosis and externally-exposed steel plate among the patients. In addition, all fractures were recovered, and the recovery time was 2.6 - 4.1 months, with the mean duration being 3.4 months. The recovery of knee function was favorable, in which 20 cases were excellent, 14 were good, and 4 were general. The excellent and good rate was 89.5%. Conclusion: Minimally invasive treatment of LCP for Schatzker Ⅰ - Ⅲ tibial plateau fracture can reduce the postoperative relocation loss, and has small trauma and stable fixation.

  15. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  16. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  17. Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies.

    Science.gov (United States)

    Almeida da Silveira, E; Levasseur, A; Lacourt, M; Elce, Y; Petit, Y

    2014-01-01

    To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the load-displacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p fracture of the apical fragment of the proximal sesamoid bone. The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

  18. [Case-control study on minimally invasive percutaneous locking compression plate internal fixation for the treatment of type II and III pilon fractures].

    Science.gov (United States)

    Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao

    2011-12-01

    To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.

  19. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  20. Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

    Science.gov (United States)

    Singh, Ashutosh Kumar; Narsaria, Nidi; G R, Arun; Srivastava, Vivek

    Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstable trochanteric fractures were randomly assigned (using a sealed envelope method) to treatment with either PFN (24 patients) or PFLCP (24 patients). Perioperative data and complications were recorded. All cases were followed up for 2 years. The groups did not differ significantly (P > .05) in operative time, reduction quality, complications, hospital length of stay, union rate, or time to union. Compared with the PFLCP group, the PFN group had shorter incisions and less blood loss. Regarding functional outcomes, there was no significant difference in mean Harris Hip Score (P = .48) or Palmer and Parker mobility score (P = .58). Both PFN and PFLCP are effective in internal fixation of unstable trochanteric femur fractures.

  1. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  3. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  4. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    Science.gov (United States)

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  5. Multi-operational tuneable Q-switched mode-locking Er fibre laser

    Science.gov (United States)

    Qamar, F. Z.

    2018-01-01

    A wavelength-spacing tuneable, Q-switched mode-locking (QML) erbium-doped fibre laser based on non-linear polarization rotation controlled by four waveplates and a cube polarizer is proposed. A mode-locked pulse train using two quarter-wave plates and a half-wave plate (HWP) is obtained first, and then an extra HWP is inserted into the cavity to produce different operation regimes. The evolutions of temporal and spectral dynamics with different orientation angles of the extra HWP are investigated. A fully modulated stable QML pulse train is observed experimentally. This is, to the author’s best knowledge, the first experimental work reporting QML operation without adding an extra saturable absorber inside the laser cavity. Multi-wavelength pulse laser operation, multi-pulse train continuous-wave mode-locking operation and pulse-splitting operations are also reported at certain HWP angles. The observed operational dynamics are interpreted as a mutual interaction of dispersion, non-linear effect and insertion loss. This work provides a new mechanism for fabricating cheap tuneable multi-wavelength lasers with QML pulses.

  6. Investigation of vertebral ''end plate sclerosis''

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.W. [Dept. of Rehabilitation Sciences, Hong Kong Polytechnic Univ., Hung Hom (Hong Kong); Mathie, A.G.; Jackson, J.E. [Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, London (United Kingdom); Hughes, S.P.F. [Div. of Surgery, Anaesthetics and Intensive Care, London (United Kingdom)

    2001-08-01

    To evaluate the association between vertebral ''end plate sclerosis'' and neck pain. A retrospective study was carried out of lateral cervical spine radiographs with a Picture Archive and Communication System (PACS). Two hundred patients' files were randomly assessed, comprising four equal groups, A to D. The mean ages of the patients were 62{+-}7.4 years, 61{+-}7.5 years, 40{+-}5.6 years and 23{+-}5.6 years respectively. In group A, all patients had symptoms of neck pain and a radiographic diagnosis of ''end plate sclerosis'' of the cervical spine. In groups B to D, asymptomatic patients were recruited and their age groups were 50-69, 30-49 and 10-29 years respectively. Using the PACS, the radiographic density and the sagittal diameter, thickness and area of the end plates at the C5 level were measured. Results and conclusions: No significant differences were found in the radiographic density of the end plates either between the symptomatic and asymptomatic groups (groups A and B), or between different age groups (groups B, C and D). A significant increase in end plate area and thickness was found, however, in both group B (P<0.005) and group C (P<0.01) in comparison with group D. This indicates that the extent of end plate sclerosis increases with age. Our results suggest that the radiographic density of cervical vertebral end plates correlates neither with neck pain nor with increasing age. The radiological sign of ''end plate sclerosis'' may be over-reported, further limiting its value in the assessment of patients with cervical spondylosis. (orig.)

  7. Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating.

    Science.gov (United States)

    Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William

    2017-11-01

    Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Development of hold down plate of INGLE fuel assembly

    International Nuclear Information System (INIS)

    Kim, Hyeong Koo; Kim, Kyu Tae

    1996-07-01

    Hold down plate for the INGLE fuel which has been designed for high performance in the standpoints of thermal margin and structural integrity compared to current fuel for YGN 3/4 and UCN 3/4 has been developed and its structural integrity has been verified based on the eh stress analysis. The design feature of the developed hold down plate has not only perfect compatibility with the reactor internals of Korea standard reactor, but also brand-new locking mechanism between upper tie plate and guide tubes. This locking mechanism introduced to the INGLE fuel provides very simple and reliable reconstitutability. In this report, finite element stress analysis with the aid of the ANSYS code as a solver and the MSC/PATRAN code as a pre and post processor were performed to verify structural integrity of the hold down plate considering various load cases which seem to be applied to the hold down plate during its lifetime. Based on the analysis results, the developed hold down plate for INGLE fuel sustains structural integrity under considered load conditions. 3 tabs., 16 figs., 9 refs. (Author)

  9. Comparison of a zero-profile anchored spacer (ROI-C) and the polyetheretherketone (PEEK) cages with an anterior plate in anterior cervical discectomy and fusion for multilevel cervical spondylotic myelopathy.

    Science.gov (United States)

    Liu, Yijie; Wang, Heng; Li, Xuefeng; Chen, Jie; Sun, Han; Wang, Genlin; Yang, Huilin; Jiang, Weimin

    2016-06-01

    We aimed to analyze the clinical and radiographic efficacy of a new zero-profile anchored spacer called the ROI-C in anterior discectomy and fusion (ACDF) for multilevel cervical spondylotic myelopathy (MCSM). We retrospectively reviewed the clinical, radiological outcomes and complications of multilevel ACDF with the ROI-C or with the polyetheretherketone (PEEK) cages with an anterior plate. From April 2011 to April 2014, 60 patients with MCSM were operated on using ACDF, with the ROI-C in 28 patients and PEEK cages with an anterior plate in 32 patients. The operative time, intraoperative blood loss, and clinical and radiological results were compared between the ROI-C group and the cage-plate group. The mean follow-up time was 23.8 ± 6.6 months, ranging from 12 to 36 months. At the first month and the last follow-up, the neck disability index (NDI) scores were decreased, and the Japanese Orthopedic Association (JOA) scores were significantly increased, compared with the presurgical measurements in both groups. There were no significant differences in NDI scores or JOA scores between the two groups (P > 0.05), but there were significant differences in the operation time, blood loss and the presence of dysphagia (P PEEK cage with an anterior plate.

  10. Automatic locking orthotic knee device

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  11. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  12. Gradual unlocking of plate boundary controlled initiation of the 2014 Iquique earthquake.

    Science.gov (United States)

    Schurr, Bernd; Asch, Günter; Hainzl, Sebastian; Bedford, Jonathan; Hoechner, Andreas; Palo, Mauro; Wang, Rongjiang; Moreno, Marcos; Bartsch, Mitja; Zhang, Yong; Oncken, Onno; Tilmann, Frederik; Dahm, Torsten; Victor, Pia; Barrientos, Sergio; Vilotte, Jean-Pierre

    2014-08-21

    On 1 April 2014, Northern Chile was struck by a magnitude 8.1 earthquake following a protracted series of foreshocks. The Integrated Plate Boundary Observatory Chile monitored the entire sequence of events, providing unprecedented resolution of the build-up to the main event and its rupture evolution. Here we show that the Iquique earthquake broke a central fraction of the so-called northern Chile seismic gap, the last major segment of the South American plate boundary that had not ruptured in the past century. Since July 2013 three seismic clusters, each lasting a few weeks, hit this part of the plate boundary with earthquakes of increasing peak magnitudes. Starting with the second cluster, geodetic observations show surface displacements that can be associated with slip on the plate interface. These seismic clusters and their slip transients occupied a part of the plate interface that was transitional between a fully locked and a creeping portion. Leading up to this earthquake, the b value of the foreshocks gradually decreased during the years before the earthquake, reversing its trend a few days before the Iquique earthquake. The mainshock finally nucleated at the northern end of the foreshock area, which skirted a locked patch, and ruptured mainly downdip towards higher locking. Peak slip was attained immediately downdip of the foreshock region and at the margin of the locked patch. We conclude that gradual weakening of the central part of the seismic gap accentuated by the foreshock activity in a zone of intermediate seismic coupling was instrumental in causing final failure, distinguishing the Iquique earthquake from most great earthquakes. Finally, only one-third of the gap was broken and the remaining locked segments now pose a significant, increased seismic hazard with the potential to host an earthquake with a magnitude of >8.5.

  13. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  14. The evaluation of the bone graft survival status in titanium cervical ...

    African Journals Online (AJOL)

    To find a better way to evaluate the bone graft survival status in cervical cages, forty-one patients suffering from one-level cervical spondylosis were enrolled in this study. All underwent anterior cervical decompression and fusion with titanium cage and plate. When followed up, another 21 patients were confirmed as ...

  15. A prospective randomized trial comparing anterior cervical discectomy and fusion versus plate-only open-door laminoplasty for the treatment of spinal stenosis in degenerative diseases.

    Science.gov (United States)

    Jiang, Yun-Qi; Li, Xi-Lei; Zhou, Xiao-Gang; Bian, Chong; Wang, Han-Ming; Huang, Jian-Ming; Dong, Jian

    2017-04-01

    For three or more involved cervical levels, there is a debate over which approach yields the best outcomes for the treatment of multilevel cervical degenerative disease. Our objective is to compare the radiological and clinical outcomes of two treatments for multilevel cervical degenerative disease: anterior cervical discectomy and fusion (ACDF) versus plate-only open-door laminoplasty (laminoplasty). Patients were randomized on a 1:1 randomization schedule with 17 patients in the ACDF group and 17 patients in the laminoplasty group. Clinical outcomes were assessed by a visual analog scale (VAS), Japanese Orthopedic Association (JOA) scores, operative time, blood loss, rates of complications, drainage volume, discharge days after surgery, and complications. The cervical spine curvature index (CI) and range of motion (ROM) were assessed with radiographs. The mean VAS score, the mean JOA score, and the rate of complications did not differ significantly between groups. The laminoplasty group had greater blood loss, a longer operative time, more drainage volume, and a longer hospital stay than the ACDF group. There were no significant differences in the CI and ROM between the two groups at baseline and at each follow-up time point. ROM in both groups decreased significantly after surgery. Both ACDF and laminoplasty are effective and safe treatments for multilevel cervical degenerative disease. ACDF causes fewer traumas than laminoplasty.

  16. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  17. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware

    Directory of Open Access Journals (Sweden)

    Radtke Roman

    2010-05-01

    Full Text Available Abstract Background Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence" utilizing conventional (non-locked implants in comparison to conventional LC-DCP (limited contact dynamic compression plate and LCP (locking compression plate stabilization, in a human cadaveric diaphyseal gap model. Methods In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. Results The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p ≤ 0.011, torsion p ≤ 0.015 but revealed similar performance under cyclic loading (p = 0.43. The Fence instrumentation with established bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p ≤ 0.017. However, all contact Fence specimens survived the cyclic test, whereas all LC-DCP constructs failed early during torsion testing (p Conclusions Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  18. DLS 5.0--the biomechanical effects of dynamic locking screws.

    Directory of Open Access Journals (Sweden)

    Stefan Döbele

    Full Text Available INTRODUCTION: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0. METHODS: Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0. A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured. RESULTS: The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N. CONCLUSIONS: The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.

  19. Alternative technique of cervical spinal stabilization employing lateral mass plate and screw and intra-articular spacer fixation

    Directory of Open Access Journals (Sweden)

    Atul Goel

    2013-01-01

    Full Text Available Aim: The author discusses an alternative technique of segmental cervical spinal fixation. Material and Methods: The subtleties of the technique are discussed on the basis of experience with 3 cases with a follow-up of between 30 and 36 months. Technique: The technique involves debridement of facetal articular cartilage, distraction of facets, jamming of ′Goel spacer′ into the articular cavity and fortification of the fixation by lateral mass plate and screw fixation. The ′double-insurance′ method of fixation is safe for vertebral artery, nerve roots and spinal neural structures and the fixation is strong. Conclusions: The discussed technique is safe and provides a strong fixation and a ground for ultimate arthrodesis.

  20. Radiological evaluation of the cervical spinal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J. [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1983-03-15

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal.

  1. Radiological evaluation of the cervical spinal trauma

    International Nuclear Information System (INIS)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J.

    1983-01-01

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal

  2. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  3. The Clinical and Economic Impact of Generic Locking Plate Utilization at a Level II Trauma Center.

    Science.gov (United States)

    Mcphillamy, Austin; Gurnea, Taylor P; Moody, Alastair E; Kurnik, Christopher G; Lu, Minggen

    2016-12-01

    In today's climate of cost containment and fiscal responsibility, generic implant alternatives represent an interesting area of untapped resources. As patents have expired on many commonly used trauma implants, generic alternatives have recently become available from a variety of sources. The purpose of this study was to examine the clinical and economic impact of a cost containment program using high quality, generic orthopaedic locking plates. The implants available for study were anatomically precontoured plates for the clavicle, proximal humerus, distal radius, proximal tibia, distal tibia, and distal fibula. Retrospective review. Level II Trauma center. 828 adult patients with operatively managed clavicle, proximal humerus, distal radius, proximal tibia, tibial pilon, and ankle fractures. Operative treatment with conventional or generic implants. The 414 patients treated with generic implants were compared with 414 patients treated with conventional implants. There were no significant differences in age, sex, presence of diabetes, smoking history or fracture type between the generic and conventional groups. No difference in operative time, estimated blood loss or intraoperative complication rate was observed. No increase in postoperative infection rate, hardware failure, hardware loosening, malunion, nonunion or need for hardware removal was noted. Overall, our hospital realized a 56% reduction in implant costs, an average savings of $1197 per case, and a total savings of $458,080 for the study period. Use of generic orthopaedic implants has been successful at our institution, providing equivalent clinical outcomes while significantly reducing implant expenditures. Based on our data, the use of generic implants has the potential to markedly reduce operative costs as long as quality products are used. Therapeutic Level III.

  4. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  5. Effect of instability of vortex streets behind circular cylinder on lock-in oscillation

    International Nuclear Information System (INIS)

    Masaya Kondo

    2005-01-01

    Full text of publication follows: The effects of the instability of vortex streets formed in the wakes of a circular cylinder on lock-in oscillation was investigated using a splitter plate and a phase-estimation methodology. The lock-in oscillation at the reduced velocity of 2.5 ≤ Vr < ∼ 3.5 is a self excited oscillation with alternate vortices. The amplitude of the lock-in oscillation is changed with the reduced velocity, although the oscillation frequency and the external force frequency caused by vortices is insensitive to the reduced velocity. Author reported that the amplitude changed with the energy input, which changed with the relationship between the phase of the external force and the phase of the cylinder displacement. The report suggested that the timing of the vortices shedding would change with the reduced velocity. The reason of the timing change, however, has not been clarified yet. This paper presents an explanation of the timing change using the instability of the vortex streets formed in the wake. The distance with a next vortex in a vortex street behind a cylinder at the lock-in condition changes with reduced velocity. On the assumption that the distance between two vortex streets formed in a wake of the cylinder is a constant, only one reduced velocity satisfied the stable condition called 'Karman Vortex Street'. It means that two vortex streets formed at the lock-in condition would be instable essentially, and the vortices would interact each other to form the stable condition. The interaction among the vortices would affect not only for the shed vortices in the wake but also for the growing-up vortex on the cylinder surface. Therefore, the instability of the vortex streets would affect the timing of the vortices shedding. A flow-induced oscillation test using a circular cylinder with a splitter plate was performed to confirm such an instability. The splitter plate was installed in the far wake of the cylinder to terminate the interaction

  6. Quantification of defects depth in glass fiber reinforced plastic plate by infrared lock-in thermography

    Energy Technology Data Exchange (ETDEWEB)

    Ranjit, Shrestha; Kim, Won Tae [Kongju National University, Cheonan (Korea, Republic of); Choi, Man Yong [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-03-15

    The increasing use of composite materials in various industries has evidenced the need for development of more effective nondestructive evaluation methodologies in order to reduce rejected parts and to optimize production cost. Infrared thermography is a noncontact, fast and reliable non-destructive evaluation technique that has received vast and growing attention for diagnostic and monitoring in the recent years. This paper describes the quantitative analysis of artificial defects in Glass fiber reinforced plastic plate by using Lockin infrared thermography. The experimental analysis was performed at several excitation frequencies to investigate the sample ranging from 2.946 Hz down to 0.019 Hz and the effects of each excitation frequency on defect detachability. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. The relationship between the phase contrast with defects depth and area was examined. Finally, phase contrast method was used to calculate the defects depth considering the thermal diffusivity of the material being inspected and the excitation frequency for which the defect becomes visible. The obtained results demonstrated the effectiveness of Lock-in infrared thermography as a powerful measurement technique for the inspection of Glass fiber reinforced plastic structures.

  7. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  8. Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation

    Science.gov (United States)

    Liao, Zhenhua; Fogel, Guy R.; Pu, Ting; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Material/Methods Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Results Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (pbiomechanical advantages compared to fusion in normalizing motion. PMID:26529430

  9. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    Science.gov (United States)

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Stiffness Matters: Part II - The Effects of Plate Stiffness on Load-Sharing and the Progression of Fusion Following ACDF In Vivo.

    Science.gov (United States)

    Peterson, Joshua M; Chlebek, Carolyn; Clough, Ashley M; Wells, Alexandra K; Batzinger, Kathleen E; Houston, John M; Kradinova, Katerina; Glennon, Joseph C; DiRisio, Darryl J; Ledet, Eric H

    2018-03-19

    Real time in vivo measurement of forces in the cervical spine of goats following anterior cervical discectomy and fusion (ACDF). To measure interbody forces in the cervical spine during the time course of fusion following ACDF with plates of different stiffnesses. Following ACDF, the biomechanics of the arthrodesis is largely dictated by the plate. The properties of the plate prescribe the extent of load-sharing through the disc space versus the extent of stress-shielding. Load-sharing promotes interbody bone formation and stress-shielding can inhibit maturation of bone. However, these principles have never been validated in vivo. Measuring in vivo biomechanics of the cervical spine is critical to understanding the complex relationships between implant design, interbody loading, load-sharing, and the progression of fusion. Anterior cervical plates of distinct bending stiffnesses were placed surgically following ACDF in goats. A validated custom force-sensing interbody implant was placed in the disc space to measure load-sharing in the spine. Interbody loads were measured in vivo in real time during the course of fusion for each plate. Interbody forces during flexion/extension were highly dynamic. In animals that received high stiffness plates, maximum forces were in extension whereas in animals that received lower stiffness plates, maximum forces were in flexion. As fusion progressed, interbody load magnitude decreased. The magnitude of interbody forces in the cervical spine is dynamic and correlates to activity and posture of the head and neck. The magnitude and consistency of forces in the interbody space correlates to plate stiffness with more compliant plates resulting in more consistent load-sharing. The magnitude of interbody forces decreases as fusion matures suggesting that smart interbody implants may be used as a diagnostic tool to indicate the progression of interbody fusion. N/A.

  11. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  12. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  13. Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

    Science.gov (United States)

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fuerst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection and one because of a comminuted radial fracture 11 days after fixation of the olecranon fracture. Complications encountered after discharge of the horses from the Equine Hospital at the Vetsuisse Faculty (University of Zurich) included implant infection (n=2) and lameness (n=3), which were successfully treated with implant removal. Despite being easier to use, LCP osteosynthesis resulted in a clinical outcome similar to DCP osteosynthesis.

  14. [Treatment type C fracture of the distal radius with locking compression plate and external fixators].

    Science.gov (United States)

    Yang, Xiang; Zhao, You-ming; Chen, Lin; Ye, Cong-cong; Guo, Wei-jun; Wang, Bo

    2013-12-01

    To compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius. From January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up. Two cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,Pmeaning (t=-1.55, P>0.05). LCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.

  15. Comparison of plate-cage construct and stand-alone anchored spacer in the surgical treatment of three-level cervical spondylotic myelopathy: a preliminary clinical study.

    Science.gov (United States)

    Shi, Sheng; Liu, Zu-De; Li, Xin-Feng; Qian, Lie; Zhong, Gui-Bin; Chen, Fang-Jing

    2015-09-01

    Although stand-alone cages were advocated to be superior to plate-cage construct (PCC) because of comparable clinical outcomes and fewer plate-related complications, cage dislocation and subsidence were frequently mentioned in multilevel fusion. There are some concerns about whether these issues can be effectively prevented in multilevel anterior cervical discectomy and fusion (ACDF) by stand-alone anchored spacer (SAAS). The aim was to compare clinical outcomes, radiologic parameters, and complications of PCC and SAAS in the treatment of three-level cervical spondylotic myelopathy (CSM). This was a retrospective comparative study. A total of 38 consecutive patients with three-level CSM (ACDF with PCC, 20 patients; ACDF with SAAS, 18 patients) were reviewed. Clinical outcomes were assessed using Japanese Orthopaedic Association and Neck Disability Index. The radiologic evaluations included cervical alignment (CA), segmental angle (SA), postoperative curvature loss (PCL), and incidence of subsidence. All the aforementioned parameters were compared before and after surgery between two groups. Besides, the aforementioned results were also compared between the two groups. The complications were also recorded. The mean follow-up period was 30.3 months. No significant differences were observed in clinical outcomes between the two groups (p>.05). Additionally, no significant differences existed in fusion rate between the two groups. There were significant differences in PCL of SA and CA and correction of SA between the two groups (pSAAS group, and the potential of SAAS to reduce the incidence of postoperative dysphagia was not proven. No other complications were observed in this study. In the surgical treatment of three-level CSM, PCC is superior to SAAS in correction and maintenance of SA and avoiding cage subsidence, although the technique of ACDF with SAAS yielded encouraging clinical outcomes and high fusion rate. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Treatment of segmental tibial fractures with supercutaneous plating.

    Science.gov (United States)

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  17. [Treatment of complex tibial plateau fractures with bilateral locking plate and bone graft].

    Science.gov (United States)

    Yan, Ying-Jie; Cheng, Zhan-Wei; Feng, Kai; Yan, Shao-Hua

    2012-07-01

    To explore the effective methods for the treatment of complex tibial plateau fractures. From May 2008 to April 2011, 28 patients with complex tibial plateau fractures were treated indirect reduction techniques, bilateral locking plate fixation combined with autologous bone grafts. There were 21 males and 7 females, with an average age of 43 years ranging from 21 to 65. There were 11 cases in Schatzker type V, 17 in VI. The effect was evaluated by Rasmussen standard on clinical and radiological. All patients were followed-up for 7 to 36 months (averaged of 21.5 months). Healing time of fracture was from 3 to 8 months (averaged 5.5 months). The results of Rasmussen scores in clinical was 4.50 +/- 1.32 in pain, 4.32 +/- 1.63 in walking ability, 4.07 +/- 1.34 in knee activity, 4.78 +/- 1.27 in stability of the knee, 4.85 +/- 1.12 in stretch knee; the results in radiation was 5.07 +/- 0.92 in articular surface collapse, 5.00 +/- 0.98 in platform widened, 5.14 +/- 0.85 in knee external varus. The effect result was excellent in 8 cases, good in 15, fair in 3 and poor in 2. The key for the treatment of complex tibial plateau fractures was to fully assess the damage as much as possible to protect the soft tissue, select the appropriate timing of surgery and surgical incision, application of indirect reduction techniques, limited incision and effective internal fixation to restore joint surface smooth and good limb alignment, early exercise, in order to achieve maximum recovery of joint function.

  18. Traumatic atlanto-occipital dissociation presenting as locked-in syndrome.

    Science.gov (United States)

    Desai, Rupen; Kinon, Merritt D; Loriaux, Daniel B; Bagley, Carlos A

    2015-12-01

    We present an unusual presentation of unstable atlanto-occipital dissociation as locked-in syndrome. Traumatic atlanto-occipital dissociation is a severe injury that accounts for 15-20% of all fatal cervical spinal injuries. A disruption occurs between the tectorial ligaments connecting the occipital condyle to the superior articulating facets of the atlas, resulting in anterior, longitudinal, or posterior translation, and it may be associated with Type III odontoid fractures. Furthermore, the dissociation may be complete (atlanto-occipital dislocation) or incomplete (atlanto-occipital subluxation), with neurologic findings ranging from normal to complete quadriplegia with respiratory compromise. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  20. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  1. A new discrete Kirchhoff-Mindlin element based on Mindlin-Reissner plate theory and assumed shear strain fields. I - An extended DKT element for thick-plate bending analysis. II - An extended DKQ element for thick-plate bending analysis

    Science.gov (United States)

    Katili, Irwan

    1993-06-01

    A new three-node nine-degree-of-freedom triangular plate bending element is proposed which is valid for the analysis of both thick and thin plates. The element, called the discrete Kirchhoff-Mindlin triangle (DKMT), has a proper rank, passes the patch test for thin and thick plates in an arbitrary mesh, and is free of shear locking. As an extension of the DKMT element, a four-node element with 3 degrees of freedom per node is developed. The element, referred to as DKMQ (discrete Kirchhoff-Mindlin quadrilateral) is found to provide good results for both thin and thick plates without any compatibility problems.

  2. DYNAMIC RESPONSE OF THICK PLATES ON TWO PARAMETER ELASTIC FOUNDATION UNDER TIME VARIABLE LOADING

    OpenAIRE

    Ozgan, Korhan; Daloglu, Ayse T.

    2014-01-01

    In this paper, behavior of foundation plates with transverse shear deformation under time variable loading is presented using modified Vlasov foundation model. Finite element formulation of thick plates on elastic foundation is derived by using an 8-noded finite element based on Mindlin plate theory. Selective reduced integration technique is used to avoid shear locking problem which arises when smaller plate thickness is considered for the evaluation of the stiffness matrices. After comparis...

  3. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  4. Centering and fixing device of a control rod guide flange on a nuclear reactor core plate

    International Nuclear Information System (INIS)

    Chevereau, G.

    1990-01-01

    The device comprises at least two pins diametrally opposite entering into holes in the core plate and self locking pads sliding into bores in the flange. These pads have a command mechanism blocking the lateral displacement of the pads on the plate [fr

  5. Optimized image processing with modified preprocessing of image data sets of a transparent imaging plate by way of the lateral view of the cervical spine

    International Nuclear Information System (INIS)

    Reissberg, S.; Hoeschen, C.; Redlich, U.; Scherlach, C.; Preuss, H.; Kaestner, A.; Doehring, W.; Woischneck, D.; Schuetze, M.; Reichardt, K.; Firsching, R.

    2002-01-01

    Purpose: To improve the diagnostic quality of lateral radiographs of the cervical spine by pre-processing the image data sets produced by a transparent imaging plate with both-side reading and to evaluate any possible impact on minimizing the number of additional radiographs and supplementary investigations. Material and Methods: One hundred lateral digital radiographs of the cervical spine were processed with two different methods: processing of each data set using the system-imminent parameters and using the manual model. The difference between the two types of processing is the level of the latitude value. Hard copies of the processed images were judged by five radiologists and three neurosurgeons. The evaluation applied the image criteria score (ICS) without conventional reference images. Results: In 99% of the lateral radiographs of the cervical spine, all vertebral bodies could be completed delineated using the manual mode, but only 76% of the images processed by the system-imminent parameters showed all vertebral bodies. Thus, the manual mode enabled the evaluation of up to two additional more caudal vertebral bodies. The manual mode processing was significantly better concerning object size and processing artifacts. This optimized image processing and the resultant minimization of supplementary investigations was calculated to correspond to a theoretical dose reduction of about 50%. (orig.) [de

  6. Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

    Directory of Open Access Journals (Sweden)

    Christian Fang

    2015-12-01

    Full Text Available CASE:: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for removal of the previous implant. Multiple long locking screws were placed in the supra-acetabular region. The patient had union in 4 months, return to function and no complication. Conclusion:: The technique allowed us to optimize implant selection and insert screws safely at difficult trajectories using minimal invasive surgery. Keywords: Hip fusion, Fracture, Plating, Minimal invasive, 3D printing

  7. An automatic mode-locked system for passively mode-locked fiber laser

    Science.gov (United States)

    Li, Sha; Xu, Jun; Chen, Guoliang; Mei, Li; Yi, Bo

    2013-12-01

    This paper designs and implements one kind of automatic mode-locked system. It can adjust a passively mode-locked fiber laser to keep steady mode-locked states automatically. So the unsteadiness of traditional passively mode-locked fiber laser can be avoided. The system transforms optical signals into electrical pulse signals and sends them into MCU after processing. MCU calculates the frequency of the signals and judges the state of the output based on a quick judgment algorithm. A high-speed comparator is used to check the signals and the comparison voltage can be adjusted to improve the measuring accuracy. Then by controlling two polarization controllers at an angle of 45degrees to each other, MCU extrudes the optical fibers to change the polarization until it gets proper mode-locked output. So the system can continuously monitor the output signal and get it back to mode-locked states quickly and automatically. States of the system can be displayed on the LCD and PC. The parameters of the steady mode-locked states can be stored into an EEPROM so that the system will get into mode-locked states immediately next time. Actual experiments showed that, for a 6.238MHz passively mode-locked fiber lasers, the system can get into steady mode-locked states automatically in less than 90s after starting the system. The expected lock time can be reduced to less than 20s after follow up improvements.

  8. Using GPS, tide gauge and altimetry data to constrain subduction parameters at the Vanuatu plate boundary.

    Science.gov (United States)

    Ballu, V.; Bouin, M.; Baillard, C.; Calmant, S.; Pelletier, B.; Crawford, W. C.; Kanas, T.; Garaebiti, E.

    2012-12-01

    The Vanuatu subduction zone, Southwest Pacific, combines several features that makes it a particularly useful place to study seismic cycles. The convergence rate is high - approximately 12 cm/yr - and the seismic cycle relatively short. Measurements of interseismic motions are helped by relatively high vertical rates, the close proximity of some islands to the plate interface and the existence of very shallow seamounts on either side of the plate interface. The Vanuatu archipelago is part of the Pacific Ring of Fire: the Australian plate subducts eastward beneath the North Fiji basin, on the western border of the Pacific Plate. High topographic features on the diving plate may contribute to locking of the plates, which can play a major role in the genesis of destructive earthquakes. GPS network points were installed in the early 1990s and the geodesy network has been densified through the years, enabling us to map interseismic horizontal and vertical deformation rates throughout the archipelago. More recently, 8 continuous GPS stations were installed, along with 3 continuous seafloor pressure gauges very near to the plate interface. We show results from GPS data collected from 1996 to 2011, that we re-processed and combined into the ITRF2008 reference frame, and altimetry and seafloor pressure data from 1999 to 2010. The GPS results show that vertical deformation rates vary both across and along the archipelago. We believe that these variations result from variable distance to the plate limit and variable locking parameters. In some areas, subsidence rates are close to one centimeter per year. In the Torres islands (at the northern end of the archipelago) where villagers face recurrent coastal flooding, we showed that this flooding is due more to ground motion than to rise in the absolute sea level, even though the sea-level rise rates are locally high and the islands uplift over the long term. In the Central area of Vanuatu, we augmented the on-land network with

  9. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    Science.gov (United States)

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P tibial fractures of young patients.

  10. Interband optical pulse injection locking of quantum dot mode-locked semiconductor laser.

    Science.gov (United States)

    Kim, Jimyung; Delfyett, Peter J

    2008-07-21

    We experimentally demonstrate optical clock recovery from quantum dot mode-locked semiconductor lasers by interband optical pulse injection locking. The passively mode-locked slave laser oscillating on the ground state or the first excited state transition is locked through the injection of optical pulses generated via the opposite transition bands, i.e. the first excited state or the ground state transition from the hybridly mode-locked master laser, respectively. When an optical pulse train generated via the first excited state from the master laser is injected to the slave laser oscillating via ground state, the slave laser shows an asymmetric locking bandwidth around the nominal repetition rate of the slave laser. In the reverse injection case of, i.e. the ground state (master laser) to the first excited state (slave laser), the slave laser does not lock even though both lasers oscillate at the same cavity frequency. In this case, the slave laser only locks to higher injection rates as compared to its own nominal repetition rate, and also shows a large locking bandwidth of 6.7 MHz.

  11. Surgical treatment of traumatic cervical facet dislocation: anterior, posterior or combined approaches?

    Directory of Open Access Journals (Sweden)

    Catarina C. Lins

    Full Text Available ABSTRACT Surgical treatment is well accepted for patients with traumatic cervical facet joint dislocations (CFD, but there is uncertainty over which approach is better: anterior, posterior or combined. We performed a systematic literature review to evaluate the indications for anterior and posterior approaches in the management of CFD. Anterior approaches can restore cervical lordosis, and cause less postoperative pain and less wound problems. Posterior approaches are useful for direct reduction of locked facet joints and provide stronger fixation from a biomechanical point of view. Combined approaches can be used in more complex cases. Although both anterior and posterior approaches can be used interchangeably, there are some patients who may benefit from one of them over the other, as discussed in this review. Surgeons who treat cervical spine trauma should be able to perform both procedures as well as combined approaches to adequately manage CFD and improve patients’ final outcomes.

  12. Active locking and entanglement in type II optical parametric oscillators

    Science.gov (United States)

    Ruiz-Rivas, Joaquín; de Valcárcel, Germán J.; Navarrete-Benlloch, Carlos

    2018-02-01

    Type II optical parametric oscillators are amongst the highest-quality sources of quantum-correlated light. In particular, when pumped above threshold, such devices generate a pair of bright orthogonally-polarized beams with strong continuous-variable entanglement. However, these sources are of limited practical use, because the entangled beams emerge with different frequencies and a diffusing phase difference. It has been proven that the use of an internal wave-plate coupling the modes with orthogonal polarization is capable of locking the frequencies of the emerging beams to half the pump frequency, as well as reducing the phase-difference diffusion, at the expense of reducing the entanglement levels. In this work we characterize theoretically an alternative locking mechanism: the injection of a laser at half the pump frequency. Apart from being less invasive, this method should allow for an easier real-time experimental control. We show that such an injection is capable of generating the desired phase locking between the emerging beams, while still allowing for large levels of entanglement. Moreover, we find an additional region of the parameter space (at relatively large injections) where a mode with well defined polarization is in a highly amplitude-squeezed state.

  13. A radiological study on the cervical spine in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Taketomi, Eiji; Sakoh, Takashi; Sunahara, Nobuhiko [Kagoshima Univ. (Japan). Faculty of Medicine

    1995-03-01

    The cervical spine was examined with the magnetic resonance imaging (MRI) and the conventional roentgenograms in 95 patients with rheumatoid arthritis. The MRI findings of upper cervical disorders were compared with various values determined in roentgenograms: the atlanto-dental interval (ADI), the space available for the spinal cord (SAC), and the Ranawat and Redlund-Johnell values. In patients with vertical setting (VS), MRI showed medullary compression in all those with abnormal Redlund-Johnell values and Ranawat values of 7 mm or less. In patients with anterior atlanto-axial subluxation, compression of the upper cervical cord was observed in all patients with SAC of 13 mm or less. In subaxial lesion of the cervical spine, MRI was found to be as good as roentgenograms in evaluating plate erosion and disc space narrowing and MRI showed extradural pannus. (author).

  14. A radiological study on the cervical spine in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Taketomi, Eiji; Sakoh, Takashi; Sunahara, Nobuhiko

    1995-01-01

    The cervical spine was examined with the magnetic resonance imaging (MRI) and the conventional roentgenograms in 95 patients with rheumatoid arthritis. The MRI findings of upper cervical disorders were compared with various values determined in roentgenograms: the atlanto-dental interval (ADI), the space available for the spinal cord (SAC), and the Ranawat and Redlund-Johnell values. In patients with vertical setting (VS), MRI showed medullary compression in all those with abnormal Redlund-Johnell values and Ranawat values of 7 mm or less. In patients with anterior atlanto-axial subluxation, compression of the upper cervical cord was observed in all patients with SAC of 13 mm or less. In subaxial lesion of the cervical spine, MRI was found to be as good as roentgenograms in evaluating plate erosion and disc space narrowing and MRI showed extradural pannus. (author)

  15. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    Science.gov (United States)

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  16. Double pass locking and spatial mode locking for gravitational wave detectors

    CERN Document Server

    Cusack, B J; Slagmolen, B; Vine, G D; Gray, M B; McClelland, D E

    2002-01-01

    We present novel techniques for overcoming problems relating to the use of high-power lasers in mode cleaner cavities for second generation laser interferometric gravitational wave detectors. Rearranging the optical components into a double pass locking regime can help to protect locking detectors from damage. Modulator thermal lensing can be avoided by using a modulation-free technique such as tilt locking, or its recently developed cousin, flip locking.

  17. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Thin-plate spline analysis of mandibular growth.

    Science.gov (United States)

    Franchi, L; Baccetti, T; McNamara, J A

    2001-04-01

    The analysis of mandibular growth changes around the pubertal spurt in humans has several important implications for the diagnosis and orthopedic correction of skeletal disharmonies. The purpose of this study was to evaluate mandibular shape and size growth changes around the pubertal spurt in a longitudinal sample of subjects with normal occlusion by means of an appropriate morphometric technique (thin-plate spline analysis). Ten mandibular landmarks were identified on lateral cephalograms of 29 subjects at 6 different developmental phases. The 6 phases corresponded to 6 different maturational stages in cervical vertebrae during accelerative and decelerative phases of the pubertal growth curve of the mandible. Differences in shape between average mandibular configurations at the 6 developmental stages were visualized by means of thin-plate spline analysis and subjected to permutation test. Centroid size was used as the measure of the geometric size of each mandibular specimen. Differences in size at the 6 developmental phases were tested statistically. The results of graphical analysis indicated a statistically significant change in mandibular shape only for the growth interval from stage 3 to stage 4 in cervical vertebral maturation. Significant increases in centroid size were found at all developmental phases, with evidence of a prepubertal minimum and of a pubertal maximum. The existence of a pubertal peak in human mandibular growth, therefore, is confirmed by thin-plate spline analysis. Significant morphological changes in the mandible during the growth interval from stage 3 to stage 4 in cervical vertebral maturation may be described as an upward-forward direction of condylar growth determining an overall "shrinkage" of the mandibular configuration along the measurement of total mandibular length. This biological mechanism is particularly efficient in compensating for major increments in mandibular size at the adolescent spurt.

  19. Assessment of Optimum Value for Dip Angle and Locking Rate Parameters in Makran Subduction Zone

    Science.gov (United States)

    Safari, A.; Abolghasem, A. M.; Abedini, N.; Mousavi, Z.

    2017-09-01

    Makran subduction zone is one of the convergent areas that have been studied by spatial geodesy. Makran zone is located in the South Eastern of Iran and South of Pakistan forming the part of Eurasian-Arabian plate's border where oceanic crust in the Arabian plate (or in Oman Sea) subducts under the Eurasian plate ( Farhoudi and Karig, 1977). Due to lack of historical and modern tools in the area, a sampling of sparse measurements of the permanent GPS stations and temporary stations (campaign) has been conducted in the past decade. Makran subduction zone from different perspectives has unusual behaviour: For example, the Eastern and Western parts of the region have very different seismicity and also dip angle of subducted plate is in about 2 to 8 degrees that this value due to the dip angle in other subduction zone is very low. In this study, we want to find the best possible value for parameters that differs Makran subduction zone from other subduction zones. Rigid block modelling method was used to determine these parameters. From the velocity vectors calculated from GPS observations in this area, block model is formed. These observations are obtained from GPS stations that a number of them are located in South Eastern Iran and South Western Pakistan and a station located in North Eastern Oman. According to previous studies in which the locking depth of Makran subduction zone is 38km (Frohling, 2016), in the preparation of this model, parameter value of at least 38 km is considered. With this function, the amount of 2 degree value is the best value for dip angle but for the locking rate there is not any specified amount. Because the proposed model is not sensitive to this parameter. So we can not expect big earthquakes in West of Makran or a low seismicity activity in there but the proposed model definitely shows the Makran subduction layer is locked.

  20. A Modified Kirchhoff plate theory for Free Vibration analysis of functionally graded material plates using meshfree method

    Science.gov (United States)

    Nguyen Van Do, Vuong

    2018-04-01

    In this paper, a modified Kirchhoff theory is presented for free vibration analyses of functionally graded material (FGM) plate based on modified radial point interpolation method (RPIM). The shear deformation effects are taken account into modified theory to ignore the locking phenomenon of thin plates. Due to the proposed refined plate theory, the number of independent unknowns reduces one variable and exists with four degrees of freedom per node. The simulated free vibration results employed by the modified RPIM are compared with the other analytical solutions to verify the effectiveness and the accuracy of the developed mesh-free method. Detail parametric studies of the proposed method are then conducted including the effectiveness of thickness ratio, boundary condition and material inhomogeneity on the sample problems of square plates. Results illustrated that the modified mesh-free RPIM can effectively predict the numerical calculation as compared to the exact solutions. The obtained numerical results are indicated that the proposed method are stable and well accurate prediction to evaluate with other published analyses.

  1. Automatic NMR field-frequency lock-pulsed phase locked loop approach.

    Science.gov (United States)

    Kan, S; Gonord, P; Fan, M; Sauzade, M; Courtieu, J

    1978-06-01

    A self-contained deuterium frequency-field lock scheme for a high-resolution NMR spectrometer is described. It is based on phase locked loop techniques in which the free induction decay signal behaves as a voltage-controlled oscillator. By pulsing the spins at an offset frequency of a few hundred hertz and using a digital phase-frequency discriminator this method not only eliminates the usual phase, rf power, offset adjustments needed in conventional lock systems but also possesses the automatic pull-in characteristics that dispense with the use of field sweeps to locate the NMR line prior to closure of the lock loop.

  2. Locke and botany.

    Science.gov (United States)

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  3. Simulation of tectonic evolution of the Kanto basin of Japan since 1 Ma due to subduction of the Pacific and Philippine sea plates and collision of the Izu-Bonin arc

    Science.gov (United States)

    Hashima, Akinori; Sato, Toshinori; Sato, Hiroshi; Asao, Kazumi; Furuya, Hiroshi; Yamamoto, Shuji; Kameo, Koji; Miyauchi, Takahiro; Ito, Tanio; Tsumura, Noriko; Kaneda, Heitaro

    2015-04-01

    The Kanto basin, the largest lowland in Japan, developed by flexure as a result of (1) the subduction of the Philippine Sea (PHS) and the Pacific (PAC) plates and (2) the collision of the Izu-Bonin arc with the Japanese island arc. Geomorphological, geological, and thermochronological data on long-term vertical movements over the last 1 My suggest that subsidence initially affected the entire Kanto basin after which the area of subsidence gradually narrowed until, finally, the basin began to experience uplift. In this study, we modelled the tectonic evolution of the Kanto basin following the method of Matsu'ura and Sato (1989) for a kinematic subduction model with dislocations, in order to quantitatively assess the effects of PHS and PAC subduction. We include the steady slip-rate deficit (permanent locking rate at the plate interface) in our model to account for collision process. We explore how the arc-arc collision process has been affected by a westerly shift in the PHS plate motion vector with respect to the Eurasian plate, thought to have occurred between 1.0-0.5 Ma, using long-term vertical deformation data to constrain extent of the locked zone on the plate interface. We evaluated the change in vertical deformation rate for two scenarios: (1) a synchronous shift in the orientation of the locked zone as PHS plate motion shifts and (2) a delayed shift in the orientation of the locked zone following a change in plate motion. Observed changes in the subsidence/uplift pattern are better explained by scenario (2), suggesting that recent (<1 My) deformation in the Kanto basin shows a lag in crustal response to the shift in plate motion. We also calculated recent stress accumulation rates and found a good match with observed earthquake mechanisms, which shows that intraplate earthquakes serve to release stress accumulated through long-term plate interactions.

  4. Comparison of Radiologic Outcomes of Different Methods in Single-Level Anterior Cervical Discectomy and Fusion.

    Science.gov (United States)

    Kwon, O Ik; Son, Dong Wuk; Lee, Sang Weon; Song, Geun Sung

    2016-09-01

    Anterior cervical discectomy and fusion (ACDF) is a choice of surgical procedure for cervical degenerative diseases associated with radiculopathy or myelopathy. However, the patients undergoing ACDF still have problems. The purpose of the present study is to evaluate the radiologic results of 3 different methods in single-level ACDF. We conducted a retrospective collection of radiological data from January 2011 to December 2014. A total of 67 patients were included in this study. The patients were divided into 3 groups by operation procedure: using stand-alone cage (group cage, n=20); polyether-ether-ketone (PEEK)-titanium combined anchored cage (group AC, n=21); and anterior cervical cage-plate (group CP, n=26). Global cervical lordosis (C2-C7 Cobb angle), fused segment height, fusion rate, and cervical range of motion (ROM) were measured and analyzed at serial preoperative, postoperative, 6-month, and final 1-year follow-up. Successful bone fusion was achieved in all patients at the final follow-up examination; however, the loss of disc height over 3 mm at the surgical level was observed in 6 patients in group cage. Groups AC and CP yielded significantly better outcomes than group cage in fused segment height and cervical ROM(p=0.01 and p=0.02, respectively). Furthermore, group AC had similar radiologic outcomes to those of group CP. The PEEK-titanium combined anchored cage may be a good alternative procedure in terms of reducing complications induced by plate after ACDF.

  5. Study of transient flow in fuel element of tubular plates. Accident: Shaft locking of primary cooling pump without opening the emergency gate; Estudio del regimen transitorio en el elemento combustible de placas tubulares. Accidente: Agarrotamiento de la bomba. No se abre la compuerta

    Energy Technology Data Exchange (ETDEWEB)

    Aguilas, F; Moneva, M A; Garcia Ramirez, L; Lopez Jimenez, J; Diaz Diaz, J

    1971-07-01

    It is analysed the thermal distribution of a fuel element of tubular plates irradiated in the JEN-1 reactor in the case of shaft locking of the primary cooling pump without opening the emergency gate. The fuel element hottest channel is studied in the position of maximum neutronic flux for three reactor power levels: 3 Hw (maximum reactor power), 2 Mw and 1 Hw. (Author) 8 refs.

  6. Complicações determinadas por placas de cloreto de polivinila (PVC na estabilização da porção cervical caudal da coluna vertebral de cães Complications determined by polyvinylchloride (PVC plates in the stabilization of caudal cervical vertebral column of dogs

    Directory of Open Access Journals (Sweden)

    Mônica Vicky Bahr Arias

    2003-12-01

    Full Text Available Em 10 cães com peso médio de 14,6kg, as vértebras cervicais 5 e 6 foram cirurgicamente desestabilizadas através da secção do disco intervertebral e, em seguida, estabilizadas com placas ortopédicas confeccionadas com PVC de 2mm de espessura, para após 180 dias, proceder-se ao estudo histológico do tecido ósseo e conjuntivo circunvizinho. Constatou-se que o PVC causou alterações ósseas que podem ter favorecido o afrouxamento dos parafusos e a falha do implante. O material induziu ainda à formação de granuloma de corpo estranho e a reações inflamatórias locais que podem ter causado degradação do material implantado. Assim, placas de PVC, apesar de proporcionarem estabilidade e alinhamento da coluna vertebral, não satisfazem a maioria das propriedades necessárias a um biomaterial, não sendo recomendadaa a sua utilização em ortopedia veterinária.In ten dogs with an average mean weight of 14,6 kg, the cervical vertebra 5 and 6 were destabilized and fixed with plates of 2mm of thickness. The purpose of this work was to verify the effect of orthopedic PVC plates on the internal stabilization of the caudal cervical spine of dogs by studying the occurrence of alterations in the bone tissue and fibrous tissue adjacent to the plate after 180 days of permanence of the material in the dogs' organism. PVC causes progressive bone alterations, which, in the long term, could promote the loosening of the screws and failure of the implant. It also induces the formation of foreign body granuloma and inflammatory reactions which could cause degradation of the implant. Thus, PVC plates do not satisfy the majority of properties required of a biomaterial, its use not being recommended in veterinary orthopedics.

  7. Innovation and Lock-in

    DEFF Research Database (Denmark)

    Cantner, Uwe; Vannuccini, Simone

    2016-01-01

    This study focuses on a well-known but yet elusive concept: (technological) lock-in. We summarize what is known about the nature of lock-in and offer a critical view on history-dependent processes based on recent contributions to the literature. We discuss if lock-ins are really inescapable......, especially when innovation is concerned. Also, we address the question if lock-in is a well-defined concept at all. To offer a fresh view on lock-in and to tackle the issues just raised, we employ the replicator dynamics model. By making a parallel between monopolization in the replicator dynamics...... and the occurrence of lock-ins, we show that the convergence of a system to a given outcome can be reversed, under certain conditions. We highlight the need for a more precise demarcation of the conceptual boundaries of lock-in and path dependence, both from the formal and the empirical side, and suggest...

  8. Assessment of Outcomes of Treatment of Fractures of Distal Femur with a Locking Plate Taking into Account Factors Influencing the Result.

    Science.gov (United States)

    Pakuła, Grzegorz; Kwiatkowski, Krzysztof; Kuczmera, Piotr; Fudalej, Piotr

    2015-10-01

    The aim of this paper is to evaluate the results of treatment of distal femoral fractures (DFF) fixed with locking plates and analysis of factors that influence the final outcome. The patients were treated at the Department of Traumatology and Orthopedics, Military Medical Institute in Warsaw, and the Department of Orthopedics and Traumatology, 4th Military Research Hospital in Wroclaw. We analysed 39 patients with 42 fractures of the distal femur. Treatment results were analysed using the KOOS and KSS scales. Factors influencing the outcome were also investigated. Statistical analysis was performed using STATISTICA v. 10. Mean KOOS scores indicate a predominance of poor outcomes, while mean KSS scores indicate good outcomes. Treatment outcomes were significantly influenced by pain and limited mobility. 1. Subjective evaluation of treatment of fractures of the distal femur using the KOOS scale per form edworse than a clinical evaluation using the KSS. 2. Post-operative management should emphasise pain relief and restoration of the performance of the treated lower limb to ensure good mobility without crutches. 3. Despite the use of modern operational methods of fracture fixation, treatment of distal femur fractures is still a challenge.

  9. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    . In this paper, we compare a lock-free implementation of a priority queue with a lock-based implementation. We perform experiments with processors of different generations and observe large performance differences for lock-free data structures depending on the processor generation. The lock-free implementation...... performs much better on the most recent processor generation. We investigate this performance trend, using a set of micro-benchmarks and show a significant difference in the overhead of atomic operations between processor generations. The lock-free implementation executes approximately three times as many...

  10. Functional Outcomes After Temporary Bridging With Locking Plates in Lisfranc Injuries

    NARCIS (Netherlands)

    van Koperen, Paul J.; de Jong, Vincent M.; Luitse, Jan S. K.; Schepers, Tim

    2016-01-01

    The standard operative treatment of Lisfranc fracture dislocations currently consists of open reduction and transarticular fixation. Recently, bridge plating has been used more often. Using joint spanning, the reduced fracture dislocation is temporary stabilized to minimize articular damage. The

  11. Simulation of tectonic evolution of the Kanto Basin of Japan since 1 Ma due to subduction of the Pacific and Philippine Sea plates and the collision of the Izu-Bonin arc

    Science.gov (United States)

    Hashima, Akinori; Sato, Toshinori; Sato, Hiroshi; Asao, Kazumi; Furuya, Hiroshi; Yamamoto, Shuji; Kameo, Koji; Miyauchi, Takahiro; Ito, Tanio; Tsumura, Noriko; Kaneda, Heitaro

    2016-06-01

    The Kanto Basin, the largest lowland in Japan, developed by flexure as a result of (1) the subduction of the Philippine Sea (PHS) and the Pacific (PAC) plates and (2) the repeated collision of the Izu-Bonin arc fragments with the Japanese island arc. Geomorphological, geological, and thermochronological data on vertical movements over the last 1 My suggest that subsidence initially affected the entire basin after which the area of subsidence gradually narrowed until, finally, the basin began to experience uplift. In this study, we modeled the tectonic evolution of the Kanto Basin following the method of Matsu'ura and Sato (1989) for a kinematic subduction model with dislocations, in order to quantitatively assess the effects of PHS and PAC subduction. We include the steady slip-rate deficit (permanent locking rate at the plate interface) in our model to account for collision process. We explore how the latest collision of the Izu Peninsula block has been affected by a westerly shift in the PHS plate motion vector with respect to the Eurasian plate, thought to have occurred between 1.0-0.5 Ma, using long-term vertical deformation data to constrain extent of the locked zone on the plate interface. We evaluated the change in vertical deformation rate for two scenarios: (1) a synchronous shift in the orientation of the locked zone as PHS plate motion shifts and (2) a delayed shift in the orientation of the locked zone following the shift in plate motion. Observed changes in the uplift/subsidence pattern are better explained by scenario (2), suggesting that recent (< 1 My) deformation in the Kanto Basin shows a lag in crustal response to the plate motion shift. We also calculated stress accumulation rates and found a good match with observed earthquake mechanisms, which shows that intraplate earthquakes serve to release stress accumulated through long-term plate interactions.

  12. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    Science.gov (United States)

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with

  13. Transduced for determining if steam generator tubes are locked in at support plate

    International Nuclear Information System (INIS)

    Hayes, J.K.

    1984-01-01

    A nuclear steam generator is described which includes a vessel, means to introduce vaporizable fluid into the bottom portion of the vessel, an outlet near the top through which vapor is discharged, a horizontal tube sheet extending across the vessel, a plurality of U-shaped tubes, having each end secured to and extending through the tube sheet, means for introducing heating fluid to one end of each of the U-shaped tubes, means for removing heating fluid from the other end of each of the U-shaped tubes, tube support means positioned within the vessel for preventing tube vibration, the tube support means including horizontally positioned means closely surrounding, but slightly spaced from each tube, means through which access can be had to the vessel interior beneath the tube sheet when the steam generator is not in operation, and testing means for determining whether or not a tube is locked into a tube support means including a longitudinal member, with a first end located inside the tube to be tested, and a second end located outside of the tube, means for securing the first end of the member to the inside of the tube, means for heating a length of the longitudinal member, and an equal length of the tube, to an elevated temperature, and means for indicating movement of the second end of the longitudinal member away from the tube end, which would indicate that the tube is locked into the support means

  14. Outdraft at Lock Approach, Tom Bevill Lock and Dam, Alabama: Hydraulic Model Investigation

    National Research Council Canada - National Science Library

    Lynch, Gary

    2001-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  15. Three-level anterior cervical discectomy and fusion in elderly patients with wedge shaped tricortical autologous graft: A consecutive prospective series

    Directory of Open Access Journals (Sweden)

    Lee Suk

    2008-01-01

    Full Text Available Background: Treatment of multilevel cervical spondylotic myelopathy/radiculopathy is a matter of debate, more so in elderly patients due to compromised physiology. We evaluated the clinical and radiological results of cervical fusion, using wedge-shaped tricortical autologous iliac graft and Orion plate for three-level anterior cervical discectomy in elderly patients. Materials and Methods: Twelve elderly patients with mean age of 69.7 years (65-76 years were treated between April 2000 and March 2005, for three-level anterior cervical discectomy and fusion, using wedge-shaped tricortical autologous iliac graft and Orion plate. Outcome was recorded clinically according to Odom′s criteria and radiologically in terms of correction of lordosis angle and intervertebral disc height span at the time of bony union. The mean follow-up was 29.8 months (12-58 months. Results: All the patients had a complete recovery of clinical symptoms after surgery. Postoperative score according to Odom′s criteria was excellent in six patients and good in remaining six. Bony union was achieved in all the patients with average union time of 12 weeks (8-20 weeks. The mean of sum of three segment graft height collapse was 2.50 mm (SD = 2.47. The average angle of lordosis was corrected from 18.2° (SD = 2.59° preoperatively to 24.9° (SD = 4.54° at the final follow-up. This improvement in the radiological findings is statistically significant (P < 0.05. Conclusion: Cervical fusion with wedge-shaped tricortical autologous iliac graft and Orion plate for three-level anterior cervical discectomy is an acceptable technique in elderly patients. It gives satisfactory results in terms of clinical outcome, predictable early solid bony union, and maintenance of disc space height along with restoration of cervical lordosis.

  16. The study of 80 MHz self starting passively mode-locked Erbium-Doped Fiber Laser via nonlinear polarization rotation with SESAM

    International Nuclear Information System (INIS)

    Qamar, F.

    2013-01-01

    Erbium-Doped Fiber Laser, EDF L, passively mode-locked via only Nonlinear Polarization Rotation, NPR, and via NPR with Semiconductor Saturable Absorber Mirror, SESAM, is studied. Self start single pulse train with pulse width of 114 fs and repetition rate (PRR) of 80 MHz has been obtained when 55 cm EDFL, passively mode-locked via NPR only. Inserting SESAM in EDFL cavity leads to shorten the pulse width up to 88 fs, increases the amplitude stability up to 96% and lower the phase noise jittering to around 26 fsec. Stable second harmonic self starting passively mode-locked EDFL with pulse width of 284 fs has also been observed only when SESAM was used in the cavity. Multi-pulsed system passively mode-locked via NPR for EDFL length of 80 cm with time difference between the successive multi-pulses ranged from few picoseconds to nanoseconds, has been observed. The time difference can be controlled by the polarizer controller and the half wave plate. Further controlling of the cavity polarization leads to developing the multiple mode locking pulses train to second harmonic mode-locking pulse train with PRR of 160MHz and pulse width of 156 fs. Three harmonic superposed trains of mode locked pulse have been achieved only when SESAM added to the cavity. (author)

  17. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Science.gov (United States)

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  18. Dexamethasone-induced radioresistance occurring independent of human papilloma virus gene expression in cervical carcinoma cells

    International Nuclear Information System (INIS)

    Rutz, H.P.; Mariotta, M.; Mirimanoff, R.O.; Knebel Doeberitz, M. von

    1998-01-01

    The aim of this study was to investigate the role of HPV 18 E6 and E7 gene products with respect to radiosensitivity of two cervical carcinoma cell lines. The two cervical carcinoma lines C4-1 and SW 756 were used in which treatment with dexamethasone allows to modulate expression levels of HPV 18 E6 and E7 genes: Upregulation in C4-1, down-regulation in SW 756. Effects of treatment with dexamethasone on plating efficiency and radiosensitivity were assessed using a clonogenic assay. Treatment with dexamethasone increased plating efficiency of the C4-1 cells, but did not affect plating efficiency of SW 756 cells. Treatment with dexamethasone induced enhanced radioresistance in both cell lines. Thus, in C4-1 cells the observed changes in radioresistance correlate to the enhancement in expression of HPV 18 genes E6/E7, whereas in SW 756, a reduced expression correlates negatively with the enhanced radioresistance. (orig./MG) [de

  19. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  20. Comparison of zero-profile anchored spacer versus plate-cage construct in treatment of cervical spondylosis with regard to clinical outcomes and incidence of major complications: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Liu WJ

    2015-09-01

    Full Text Available Weijun Liu,1,* Ling Hu,2,* Junwen Wang,1 Ming Liu,1 Xiaomei Wang3 1Department of Orthopedics, Pu Ai Hospital, Affiliated to Tongji Medical College, Huazhong University of Science and Technology, 2Department of Anesthesiology, Tianyou Hospital, Affiliated to Wuhan University of Science and Technology, 3Department of Biological Science and Technology, Wuhan Bioengineering Institute, Wuhan, People’s Republic of China *These authors contributed equally to this work Purpose: Meta-analysis was conducted to evaluate whether zero-profile anchored spacer (Zero-P could reduce complication rates, while maintaining similar clinical outcomes compared to plate-cage construct (PCC in the treatment of cervical spondylosis. Methods: All prospective and retrospective comparative studies published up to May 2015 that compared the clinical outcomes of Zero-P versus PCC in the treatment of cervical spondylosis were acquired by a comprehensive search in PubMed and EMBASE. Exclusion criteria were non-English studies, noncomparative studies, hybrid surgeries, revision surgeries, and surgeries with less than a 12-month follow-up period. The main end points including Japanese Orthopedic Association (JOA and Neck Disability Index (NDI scores, cervical lordosis, fusion rate, subsidence, and dysphagia were analyzed. All studies were analyzed with the RevMan 5.2.0 software. Publication biases of main results were examined using Stata 12.0. Results: A total of 12 studies were included in the meta-analysis. No statistical difference was observed with regard to preoperative or postoperative JOA and NDI scores, cervical lordosis, and fusion rate. The Zero-P group had a higher subsidence rate than the PCC group (P<0.05, risk difference =0.13, 95% confidence interval [CI] 0.00–0.26. However, the Zero-P group had a significantly lower postoperative dysphagia rate than the PCC group within the first 2 weeks (P<0.05, odds ratio [OR] =0.64, 95% CI 0.45–0.91, at the 6th month [P

  1. Spondilitis Tuberkulosa Cervical

    Directory of Open Access Journals (Sweden)

    Roni Eka Saputra

    2015-05-01

    Full Text Available Abstrak Spondilitis tuberkulosa servikalis adalah penyakit yang cukup jarang dijumpai, hanya berkisar 2-3% dariseluruh kasus spondilitis tuberkulosa. Gambaran klinis sangat bervariasi, mulai dari gejala ringan dan tidak spesifikhingga komplikasi neurologis yang berat. Seorang wanita berusia 29 tahun datang dengan keluhan lemah keempatanggota gerak yang semakin memberat dalam 10 hari terakhir yang didahului oleh nyeri leher yang menjalar ke bahudan lengan sejak 6 bulan sebelumnya. Nyeri awalnya dirasakan sebagai keterbatasan gerakan leher saat menolehkesamping kiri dan kanan serta menundukkan kepala. Nyeri dirasakan semakin berat dengan pergerakan danberkurang jika istirahat. Pasien mengalami penurunan berat badan sejak 2 bulan terakhir. Tidak dijumpai riwayat batukatau nyeri dada. Pemeriksaan neurologis menunjukkan kelemahan  pada keempat ekstremitas. Hasil laboratoriumditemukan peningkatan Laju Endap Darah (LED. Rontgen foto toraks dalam batas normal. Roentgen foto cervicalmenunjukkan destruksi setinggi C5. MRI cervical menunjukkan destruksi pada korpus C5-6 dengan penyempitan padadiscus intervertebrae C5-6 disertai dengan  massa/abses paravertebral dengan penekanan ke posterior. MRI Thorakaltampak destruksi corpus verebre T4,5 dengan diskus intervertebralis yang menyempit. Sugestif suatu spondilitistuberkulosa. Pasien dilakukan tindakan pembedahan anterior corpectomi melalui microscopic surgery dengan graftdari iliac sinistra, serta insersi anterior plate 1 level. Hasil pemeriksaan patologi anatomi menunjukkan spodilitis TBCkaseosa. Pada spondilitis vertebre T4,5 dilakukan laminectomi, debridement costotrasversektomi, dan stabilisasidengan pedicle screw T2, T3, dan T5. Pasien diterapi dengan obat antituberkulosis. Keadaan pasien saat ini, pasiensudah bisa beraktifitas normal dengan motorik dan sensorik baik. Spondilitis tuberkulosa merupakan bentuktuberkulosa tulang yang paling sering dijumpai. Spondilitis tuberkulosa cervical berkisar 2

  2. Quantum noise locking

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Mikhailov, Eugeniy E; Goda, Keisuke; Lam, Ping Koy; Grosse, Nicolai; Gray, Malcolm B; Mavalvala, Nergis; McClelland, David E

    2005-01-01

    Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, cannot rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector

  3. ''Old'' locked inflation

    International Nuclear Information System (INIS)

    Liu, Yang; Piao, Yun-Song; Si, Zong-Guo

    2009-01-01

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' φ. Instead of rolling down along the potential, the φ field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape

  4. Dynamic Analysis of Thick Plates Including Deep Beams on Elastic Foundations Using Modified Vlasov Model

    Directory of Open Access Journals (Sweden)

    Korhan Ozgan

    2013-01-01

    Full Text Available Dynamic analysis of foundation plate-beam systems with transverse shear deformation is presented using modified Vlasov foundation model. Finite element formulation of the problem is derived by using an 8-node (PBQ8 finite element based on Mindlin plate theory for the plate and a 2-node Hughes element based on Timoshenko beam theory for the beam. Selective reduced integration technique is used to avoid shear locking problem for the evaluation of the stiffness matrices for both the elements. The effect of beam thickness, the aspect ratio of the plate and subsoil depth on the response of plate-beam-soil system is analyzed. Numerical examples show that the displacement, bending moments and shear forces are changed significantly by adding the beams.

  5. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers.

    Science.gov (United States)

    Jin, Tian; Yuan, Heliang; Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-12-04

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio ( C / N ₀) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C / N ₀ can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis.

  6. Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc

    International Nuclear Information System (INIS)

    Biederer, J.; Hutzelmann, A.; Heller, M.; Rama, B.

    1999-01-01

    Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with local symptoms can be evaluated with follow-up X-rays and functional imaging. (orig.) [de

  7. Lateral cervical puncture for cervical myelography

    International Nuclear Information System (INIS)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck

    1985-01-01

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media

  8. Lateral cervical puncture for cervical myelography

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media.

  9. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. 49 CFR 236.766 - Locking, movable bridge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  11. Using the Vertical Component of the Surface Velocity Field to Map the Locked Zone at Cascadia Subduction Zone

    Science.gov (United States)

    Moulas, E.; Brandon, M. T.; Podladchikov, Y.; Bennett, R. A.

    2014-12-01

    At present, our understanding of the locked zone at Cascadia subduction zone is based on thermal modeling and elastic modeling of horizontal GPS velocities. The thermal model by Hyndman and Wang (1995) provided a first-order assessment of where the subduction thrust might be cold enough for stick-slip behavior. The alternative approach by McCaffrey et al. (2007) is to use a Green's function that relates horizontal surface velocities, as recorded by GPS, to interseismic elastic deformation. The thermal modeling approach is limited by a lack of information about the amount of frictional heating occurring on the thrust (Molnar and England, 1990). The GPS approach is limited in that the horizontal velocity component is fairly insensitive to the structure of the locked zone. The vertical velocity component is much more useful for this purpose. We are fortunate in that vertical velocities can now be measured by GPS to a precision of about 0.2 mm/a. The dislocation model predicts that vertical velocities should range up to about 20 percent of the subduction velocity, which means maximum values of ~7 mm/a. The locked zone is generally entirely offshore at Cascadia, except for the Olympic Peninsula region, where the underlying Juan De Fuca plate has an anomalously low dip. Previous thermal and GPS modeling, as well as tide gauge data and episodic tremors indicate the locked zone there extends about 50 to 75 km onland. This situation provides an opportunity to directly study the locked zone. With that objective in mind, we have constructed a full 3D geodynamic model of the Cascadia subduction zone. At present, the model provides a full representation of the interseismic elastic deformation due to variations of slip on the subduction thrust. The model has been benchmarked against the Savage (2D) and Okada (3D) analytical solutions. This model has an important advantage over traditional dislocation modeling in that we include temperature-sensitive viscosity for the upper and

  12. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  13. Research of mechanism of density lock

    International Nuclear Information System (INIS)

    Wang Shengfei; Yan Changqi; Gu Haifeng

    2010-01-01

    Mechanism of density lock was analyzed according to the work conditions of density lock. The results showed that: the stratification with no disturbance satisfied the work conditions of density lock; fluids between the stratification were not mixed at the condition of connected to each other; the density lock can be open automatically by controlled the pressure balance at the stratification. When disturbance existed, the stratification might be broken and mass would be transferred by convection. The stability of stratification can be enhanced by put the special structure in density lock to ensure the normal work of density lock. At last, the minimum of heat loss in density lock was also analyzed. (authors)

  14. Resultados clínicos e radiológicos en serie de artrodesis cervical anterior con caja de fusión intersomática y placa Resultados clínicos e radiológicos em série de artrodese cervical anterior com dispositivo de fusão intersomática e placa Clinical and radiologica outcomes in series of anterior cervical fusion with intersomatic cage and plate

    Directory of Open Access Journals (Sweden)

    Lyonel Beaulieu Lalanne

    2012-06-01

    pacientes submetidos a artrodese cervical anterior com dispositivo de fusão intersomática (CAGE e placa. MÉTODOS: Análise retrospectiva de série de pacientes submetidos a artrodese cervical anterior com dispositivo de fusão intersomática e placa entre 2004 e 2009. Revisão de fichas clínicas e radiografias, registro de idade, sexo, diagnósticos, nível operado, complicações, evolução clínica e radiológica. Técnica cirúrgica de Smith-Robinson. Os dispositivos de fusão intersomática foram preenchidos com substitutos ósseos. A deambulação ocorreu 12 horas depois da cirurgia, alta às 48 horas, colar cervical intermitente por 2 semanas. Avaliação clínica pelos critérios de Odom. Acompanhamento de 17 a 78 meses. RESULTADOS: Diagnósticos: hérnia de núcleo pulposo (HNP cervical, 44 (71%, mielopatia, 11 (17,7%, fratura 7 (11,3%. Nível 1: 44 (71%, Nível 2: 15 (24,2%, Nível 3: (4,8%. O nível C5-C6 incluiu 92% dos casos. Alívio da dor radicular: 60 (97%. Recuperação do déficit neurológico: 59 (95,2%. Alívio da mielopatia: 8/11 pacientes (73%. Alívio da dor cervical: 56 (90%. Resultados clínicos: 91,9% excelentes e bons. Complicações (12,9%: 4 disfagias transitórias (6,5%, 1 disfagia permanente (1,6%, 2 disfonias transitórias (3,3%, 1 subsidência com afrouxamento do implante e fratura assintomática da placa (1,6%. Não houve pseudoartrose. CONCLUSÕES: Esta série apresenta bons resultados clínicos, com alivio da dor e recuperação neurológica comparáveis aos encontrados na literatura. O uso da caixa de fusão intersomática evita complicações na região doadora e quando é associado à placa cervical anterior permite fixação intersomática imediata, proporcionando suporte estrutural adequado, com bons resultados e sem complicações a longo prazo.OBJECTIVES: To analyze the clinical and radiological results of a series of patients undergoing anterior cervical arthrodesis with cage and plate. METHODS: Retrospective analysis of

  15. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  16. Escaping carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, G.C.

    2002-01-01

    This article explores the climate policy implications of the arguments made in ''Understanding carbon lock-in'' (Unruh, 2000), which posited that industrial countries have become locked-into fossil fuel-based energy systems through path dependent processes driven by increasing returns to scale. Carbon lock-in arises through technological, organizational, social and institutional co-evolution, ''culminating'' in what was termed as techno-institutional complex (TIC). In order to resolve the climate problem, an escape from the lock-in condition is required. However, due to the self-referential nature of TIC, escape conditions are unlikely to be generated internally and it is argued here that erogenous forces are probably required. (author)

  17. Analysis of cervical and global spine alignment under Roussouly sagittal classification in Chinese cervical spondylotic patients and asymptomatic subjects.

    Science.gov (United States)

    Yu, Miao; Zhao, Wen-Kui; Li, Mai; Wang, Shao-Bo; Sun, Yu; Jiang, Liang; Wei, Feng; Liu, Xiao-Guang; Zeng, Lin; Liu, Zhong-Jun

    2015-06-01

    To explore the relationship between cervical spine and the global spine alignment and to postulate the hypotheses that a lordotic alignment of cervical spine is not the only standard to identify asymptomatic subjects, and the degenerative modification of cervical curves depends primarily on their spinal-pelvic alignment. A cohort of 120 cases of Chinese asymptomatic subjects and a cohort of 121 cases of Chinese cervical spondylotic patients were recruited prospectively from 2011 to 2012. Roussouly Classification was utilized to categorize all subjects and patients according to their thoracic spine, lumbar spine and pelvic alignment. The cervical alignments were evaluated as lordosis, straight, sigmoid or kyphosis. Through the lateral X-ray images of neutral cervical and global spine, a number of parameters were measured and analyzed, including pelvic incidence, pelvic tilt, sacral slope, thoracic kyphosis (TK), lumbar lordosis, global cervical angles (angles between two lines parallel with posterior walls of C2 and C7), practical cervical angles (the addition of different cervical end plate angles from C3 to C7, and inter-vertebral angles from C23 to C67), T1 slope, spinal sacral angles (SSA), Hip to C7/Hip to Sacrum and C0-C2 angle. The percentages of cervical lordosis were 28.3% and 36.4% in asymptomatic and spondylotic group, respectively. The cervical spine alignments correlated with Roussouly types of global spine alignment in both asymptomatic and cervical spondylotic group (P inter-vertebral angle in Roussouly Type 2 at C4-5 and C5-6 levels (P = 0.04 and 0.04, respectively), and in Roussouly Type 3 at C6-7 level (P = 0.01). The SSA showed significant difference between Roussouly Type 2 and 4 in asymptomatic subjects (P = 0.00), and between Type 1 and 3, 1 and 4, 2 and 3, 2 and 4 in cervical spondylotic patients (P = 0.01, 0.02, 0.00 and 0.01, respectively). The T1 slope was significantly different among Roussouly types (P = 0.04) with its largest value in

  18. Homodyne locking of a squeezer.

    Science.gov (United States)

    Heurs, M; Petersen, I R; James, M R; Huntington, E H

    2009-08-15

    We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.

  19. 49 CFR 236.765 - Locking, mechanical.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  20. Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Directory of Open Access Journals (Sweden)

    Juerg Sonderegger

    2010-01-01

    Full Text Available Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. 

  1. A new classification for cervical vertebral injuries: influence of CT

    International Nuclear Information System (INIS)

    Daffner, R.H.; Brown, R.R.; Goldberg, A.L.

    2000-01-01

    Objective. Computed tomography (CT) has been demonstrated to be superior to radiography in identifying cervical vertebral injuries. However, many of these injuries may not be clinically significant, and require only minimal symptomatic and supportive treatment. It is therefore imperative that radiologists and spine surgeons have criteria for distinguishing between those injuries requiring surgical stabilization and those that do not. The authors propose a new classification of cervical vertebral injuries into two categories: major and minor.Design and patients. A data base, acquired on 1052 separate cervical injuries in 879 patients seen between 1983 and 1998, was reviewed. Four categories of injury based on mechanism [hyperflexion (four variants), hyperextension (two variants), rotary (two variants), and axial compression (five variants)] were identified. ''Major'' injuries are defined as having either radiographic or CT evidence of instability with or without associated localized or central neurologic findings, or have the potential to produce the latter. ''Minor'' injuries have no radiographic and/or CT evidence of instability, are not associated with neurologic findings, and have no potential to cause the latter.Results and conclusions. Cervical injury should be classified as ''major'' if the following radiographic and/or CT criteria are present: displacement of more than 2 mm in any plane, wide vertebral body in any plane, wide interspinous/interlaminar space, wide facet joints, disrupted posterior vertebral body line, wide disc space, vertebral burst, locked or perched facets (unilateral or bilateral), ''hanged man'' fracture of C2, dens fracture, and type III occipital condyle fracture. All other types of fractures may be considered ''minor''. (orig.)

  2. Preliminary experience of titanium mesh cages for pathological fracture of middle and lower cervical vertebrae.

    Science.gov (United States)

    Chuang, Hao-Che; Wei, Sung-Tai; Lee, Han-Chung; Chen, Chun-Chung; Lee, Wen-Yuen; Cho, Der-Yang

    2008-11-01

    The advantages and disadvantages of titanium mesh cages (TMCs) assisted by anterior cervical plates (ACPs) for interbody fusion following cervical corpectomy were investigated. Between January 2002 and September 2006, 17 patients with cervical radiculomyelopathy caused by metastasis-induced pathologic fractures were selected for anterior corpectomy. TMCs were inserted into the post-corpectomy defect and stabilized by placement of ACPs filled with Triosite. Post-operative plain X-ray films indicated maintenance of spinal stability. No ceramic, donor site or surgery-related complications were observed. True trabeculation was observed in axial and reconstructive CT scans in all surviving patients one year after surgery. Neurological recovery, pain control, and good quality of life were achieved. Short hospital stays, minimal blood loss, short operation times and brief periods of bed confinement were also observed. We conclude that a TMC assisted by an ACP is safe and effective for interbody fusion following cervical corpectomy for pathological fractures resulting from cervical vertebral metastases.

  3. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  4. Surgical treatment of proximal humerus fractures using PHILOS plate

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    2014-10-01

    Full Text Available 【Abstract】Objective: To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS plate for proximal humerus fractures. Methods: We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012. There were 35 men and 16 women with a mean age of 38 years (range 24-68. There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years. According to Neer classification system, 8, 15 and 23 patients had 2-part, 3-part, and 4-part fractures, respectively and 5 patients had 4-part fracture dislocation. All surgeries were carried out at our tertiary care trauma centre. Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score. Results: The mean follow-up period was 30 months (range 12-44 months. Two patients were lost to followup. Of the remaining 49 patients, all fractures were united clinically and radiologically. The mean time for radiological union was 12 weeks (range 8-20 weeks. At the final follow-up the mean Constant-Murley score was 79 (range 50-100. The results were excellent in 25 patients, good in 13 patients, fair in 6 atients and poor in 5 patients. During the follow-up, four cases of varus malunion, one case of subacromial impingement, one case of deep infection, one case of intraarticular screw penetration and one case of failure of fi xation were noted. No cases of avascular necrosis, hardware failure, locking screw loosening or nonunion were noted. Conclusion: PHILOS provides stable fixation in proximal humerus fractures. To prevent potential complications like avascular necrosis, meticulous surgical dissection to preserve vascularity of humeral head is necessary. Key words: Proximal humerus fracture; Fracture fixation, internal; Proximal humeral internal locking system

  5. The Advanced Thread-Locking Mechanism

    Science.gov (United States)

    Weiss, Wolfgang

    2005-12-01

    Locking of threaded members is accomplished by a wide variety of engineering solutions. Generally, in terms of separate locking devices or by built-in locking features such as friction generating means.In regard of space flight vehicles, threaded joints are subject to severe vibration loads during launch, maneuvering, and reentry. This requires fastening systems which are capable to join structural members and attach accessories or equipment in a secure manner. However, manned spacecraft and especially payload components will be subject to installation activity during orbital or interstellar flight maintenance, repair, or mission modification. This, in turn, requires fast separation and engaging of the concerned fasteners, yet providing performance characteristics for high reliable and safe joints.The further described Advanced Thread Locking Mechanism (ATLM) has been developed to combine the merits of both, safe joining technique and a fast installation process. The ATLM uses a freewheel which is securely installed in one part of the threaded member and releasable coupled with the engaged counterpart. While screwing the threaded members together, once coupled, the freewheel will allow free mating of the threaded members including torquing to the desired value. The moment, the pair of threaded fasteners is forced to unscrew (by intended or unintended occurrence of torque in the undoing direction) the freewheel does lock instantly. Disengaging the coupling between the members of the threaded joint takes a separate release action.Owing to the nature of the ATLM, there are a number of design variants ready for implementation.Threaded fasteners in ATLM design are highly recommended for mechanical joints subject to fastening and unfastening during Extra Vehicular Activity (EVA) in course of space flight operations. This is justified through:1. Threaded members mate free running, thus, torque values preset at the wrenching tool are not influenced by varying prevailing

  6. Limiting Impact Force Due to Yielding and Buckling of the Plates and Internal Structural Frame at the Bow of a Barge during Its Head-on Impact with a Bullnose or Cellular Structure

    Science.gov (United States)

    2009-08-01

    Locks and Dam. ERDC/ITL TR-09-3 16 The proposed flexible approach walls at Lock and Dams 22 and 25 consist of precast concrete beams supported...Figures 2.3 and 2.5. The rounded hull plate connecting the front and side hull plates (in blue) is shown in brown in Figures 2.2 and 2.3. Figure 2.4...approach angle column in Table 3.1 is of no consequence for these analyses. Table 3.1. Three design load condition categories, frequency of loadings

  7. Drilling the near cortex with elongated figure-of-8 holes to reduce the stiffness of a locking compression plate construct.

    Science.gov (United States)

    Chen, Jerry Yongqiang; Zhou, Zhihong; Ang, Benjamin Fu Hong; Yew, Andy Khye Soon; Chou, Siaw Meng; Chia, Shi-Lu; Koh, Joyce Suang Bee; Howe, Tet Sen

    2015-12-01

    To compare the stiffness of locking compression plate (LCP) constructs with or without drilling the near cortex with elongated figure-of-8 holes. 24 synthetic bones were sawn to create a 10-mm gap and were fixed with a 9-hole 4.5-mm narrow LCP. In 12 bones, the near cortex of the adjacent holes to the LCP holes was drilled to create elongated figure-of-8 holes before screw insertion. The stiffness of LCP constructs under axial loading or 4-point bending was assessed by (1) dynamic quasi-physiological testing for fatigue strength, (2) quasi-static testing for stiffness, and (3) testing for absolute strength to failure. None of the 24 constructs had subcatastrophic or catastrophic failure after 10 000 cycles of fatigue loading (p=1.000). The axial stiffness reduced by 16% from 613±62 to 517±44 N/mm (p=0.012) in the case group, whereas the bending stiffness was 16±1 Nm2 in both groups (p=1.000). The maximum axial load to catastrophic failure was 1596±84 N for the control group and 1627±48 N for the case group (p=0.486), whereas the maximum bending moment to catastrophic failure was 79±12 and 80±10 Nm, respectively (p=0.919). Drilling the near cortex with elongated figure-of-8 holes reduces the axial stiffness of the LCP construct, without compromising its bending stiffness or strength.

  8. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  9. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  10. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical

  11. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  12. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    Science.gov (United States)

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  13. Anterior cervical spine surgery-associated complications in a retrospective case-control study.

    Science.gov (United States)

    Tasiou, Anastasia; Giannis, Theofanis; Brotis, Alexandros G; Siasios, Ioannis; Georgiadis, Iordanis; Gatos, Haralampos; Tsianaka, Eleni; Vagkopoulos, Konstantinos; Paterakis, Konstantinos; Fountas, Kostas N

    2017-09-01

    Anterior cervical spine procedures have been associated with satisfactory outcomes. However, the occurrence of troublesome complications, although uncommon, needs to be taken into consideration. The purpose of our study was to assess the actual incidence of anterior cervical spine procedure-associated complications and identify any predisposing factors. A total of 114 patients undergoing anterior cervical procedures over a 6-year period were included in our retrospective, case-control study. The diagnosis was cervical radiculopathy, and/or myelopathy due to degenerative disc disease, cervical spondylosis, or traumatic cervical spine injury. All our participants underwent surgical treatment, and complications were recorded. The most commonly performed procedure (79%) was anterior cervical discectomy and fusion (ACDF). Fourteen patients (12.3%) underwent anterior cervical corpectomy and interbody fusion, seven (6.1%) ACDF with plating, two (1.7%) odontoid screw fixation, and one anterior removal of osteophytes for severe Forestier's disease. Mean follow-up time was 42.5 months (range, 6-78 months). The overall complication rate was 13.2%. Specifically, we encountered adjacent intervertebral disc degeneration in 2.7% of our cases, dysphagia in 1.7%, postoperative soft tissue swelling and hematoma in 1.7%, and dural penetration in 1.7%. Additionally, esophageal perforation was observed in 0.9%, aggravation of preexisting myelopathy in 0.9%, symptomatic recurrent laryngeal nerve palsy in 0.9%, mechanical failure in 0.9%, and superficial wound infection in 0.9%. In the vast majority anterior cervical spine surgery-associated complications are minor, requiring no further intervention. Awareness, early recognition, and appropriate management, are of paramount importance for improving the patients' overall functional outcome.

  14. A new classification for cervical vertebral injuries: influence of CT

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H.; Brown, R.R.; Goldberg, A.L. [Department of Diagnostic Radiology, Allegheny University Hospitals, Allegheny General, Pittsburgh, PA (United States)

    2000-03-30

    Objective. Computed tomography (CT) has been demonstrated to be superior to radiography in identifying cervical vertebral injuries. However, many of these injuries may not be clinically significant, and require only minimal symptomatic and supportive treatment. It is therefore imperative that radiologists and spine surgeons have criteria for distinguishing between those injuries requiring surgical stabilization and those that do not. The authors propose a new classification of cervical vertebral injuries into two categories: major and minor.Design and patients. A data base, acquired on 1052 separate cervical injuries in 879 patients seen between 1983 and 1998, was reviewed. Four categories of injury based on mechanism [hyperflexion (four variants), hyperextension (two variants), rotary (two variants), and axial compression (five variants)] were identified. ''Major'' injuries are defined as having either radiographic or CT evidence of instability with or without associated localized or central neurologic findings, or have the potential to produce the latter. ''Minor'' injuries have no radiographic and/or CT evidence of instability, are not associated with neurologic findings, and have no potential to cause the latter.Results and conclusions. Cervical injury should be classified as ''major'' if the following radiographic and/or CT criteria are present: displacement of more than 2 mm in any plane, wide vertebral body in any plane, wide interspinous/interlaminar space, wide facet joints, disrupted posterior vertebral body line, wide disc space, vertebral burst, locked or perched facets (unilateral or bilateral), ''hanged man'' fracture of C2, dens fracture, and type III occipital condyle fracture. All other types of fractures may be considered ''minor''. (orig.)

  15. Paired anterior spinal arteries in a case of locked-in syndrome

    International Nuclear Information System (INIS)

    Kawamura, J.; Matsubayashi, K.; Fukuyama, H.; Kitanaka, H.

    1981-01-01

    Paired anterior spinal arteries have rarely been demonstrated angiographically, although several anatomical studies have shown that they are not uncommonly observed. This report describes the angiographic and autopsy findings of such a variation, which was observed in a 65-year-old man with a locked-in syndrome. The paired trunks of the anterior spinal artery were visualized in a retrograde fashion through the left inferior thyroid artery and a radical branch at the 5th cervical level by left retrograde brachial angiography. The uppermost segments of either vertebral artery and the lower portion of the basilar artery were opacified through these channels. The autopsy confirmed the paired trunks of the anterior spinal artery, occlusion of the vertebral arteries just caudal to the origin of the main branches of the anterior spinal artery, and an old infarct involving the pontine tegmentum and cerebellum. (orig.)

  16. Globalizing carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, Gregory C.; Carrillo-Hermosilla, Javier

    2006-01-01

    This paper extends the arguments surrounding carbon lock-in elaborated in Unruh (Energy Policy 28 (2000) 817; 30 (2002) 317) to countries currently undergoing industrialization. It argues that, for numerous reasons, industrializing countries are unlikely to leapfrog carbon intensive energy development. On the contrary, carbon lock-in may be globalizing and could further constrain climate change mitigation options. It is then argued that many policy recommendations ignore carbon lock-in, possibly limiting their potential for successful implementation. The paper then discusses four policy approaches that appear to have advantages given lock-in conditions. It is recognized, however, that relative ease of implementation does not necessarily equate with superiority. Instead, it is merely a path dependent outcome of past development decisions. Pursuing policies on the basis of relative implementation ease may help address the issue of climate change, but could also result in sub-optimal outcomes along other dimensions of sustainable development

  17. LOCKS AND KEYS SERVICE

    CERN Multimedia

    Locks and Keys Service

    2002-01-01

    The Locks and Keys service (ST/FM) will move from building 55 to building 570 from the 2nd August to the 9th August 2002 included. During this period the service will be closed. Only in case of extreme urgency please call the 164550. Starting from Monday, 12th August, the Locks and Keys Service will continue to follow the activities related to office keys (keys and locks) and will provide the keys for furniture. The service is open from 8h30 to 12h00 and from 13h00 to 17h30. We remind you that your divisional correspondents can help you in the execution of the procedures. We thank you for your comprehension and we remain at your service to help you in solving all the matters related to keys for offices and furniture. Locks and Keys Service - ST Division - FM Group

  18. 49 CFR 236.761 - Locking, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  19. 49 CFR 236.105 - Electric lock.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  20. Assessing carbon lock-in

    International Nuclear Information System (INIS)

    Erickson, Peter; Kartha, Sivan; Lazarus, Michael; Tempest, Kevin

    2015-01-01

    The term ‘carbon lock-in’ refers to the tendency for certain carbon-intensive technological systems to persist over time, ‘locking out’ lower-carbon alternatives, and owing to a combination of linked technical, economic, and institutional factors. These technologies may be costly to build, but relatively inexpensive to operate and, over time, they reinforce political, market, and social factors that make it difficult to move away from, or ‘unlock’ them. As a result, by investing in assets prone to lock-in, planners and investors restrict future flexibility and increase the costs of achieving agreed climate protection goals. Here, we develop a straight-forward approach to assess the speed, strength, and scale of carbon lock-in for major energy-consuming assets in the power, buildings, industry, and transport sectors. We pilot the approach at the global level, finding that carbon lock-in is greatest, globally, for coal power plants, gas power plants, and oil-based vehicles. The approach can be readily applied at the national or regional scale, and may be of particular relevance to policymakers interested in enhancing flexibility in their jurisdictions for deeper emissions cuts in the future, and therefore in limiting the future costs associated with ‘stranded assets’. (letter)

  1. Phase-locked Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1991-01-01

    Detailed experimental characterization of the phase-locking at both DC and at microwave frequencies is presented for two closely spaced Josephson soliton (fluxon) oscillators. In the phase-locked state, the radiated microwave power exhibited an effective gain. With one common bias source......, a frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. The interacting soliton oscillators were modeled by two inductively coupled nonlinear transmission lines...

  2. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

    DEFF Research Database (Denmark)

    Froberg, Lonnie; Troelsen, Anders; Brix, Michael

    2012-01-01

    Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during...

  3. Comparable clinical and radiological outcomes between skipped-level and all-level plating for open-door laminoplasty.

    Science.gov (United States)

    Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Cheung, Amy Yim Ling; Lui, Darren; Cheung, Kenneth M C

    2018-06-01

    To compare the clinical and radiological outcomes between skipped-level and all-level plating for cervical laminoplasty. Patients with cervical spondylotic myelopathy (CSM) treated by open-door laminoplasty with minimum 2-year postoperative follow-up were included. All patients had opening from C3-6 or C3-7 and were divided into skipped-level or all-level plating groups. Japanese Orthopaedic Association (JOA) scores and canal measurements were obtained preoperatively, immediate (within 1 week) postoperatively, and at 2, 6 weeks, 3, 6 and 12 months postoperatively. Paired t test was used for comparative analysis. Receiver operating characteristic analysis was used to determine the canal expansion cutoff for spring-back closure. A total of 74 subjects were included with mean age of 66.1 ± 11.3 years at surgery. Of these, 32 underwent skipped-level plating and 42 underwent all-level plating. No significant differences were noted between the two groups at baseline and follow-up. Spring-back closure was observed in up to 50% of the non-plated levels within 3 months postoperatively. The cutoff for developing spring-back closure was 7 mm canal expansion for C3-6. No differences were observed in JOA scores and recovery rates between the two groups. None of the patients with spring-back required reoperation. There were no significant differences between skipped-level and all-level plating in terms of JOA or recovery rate, and canal diameter differences. This has tremendous impact on saving costs in CSM management as up to two plates per patient undergoing a standard C3-6 laminoplasty may be omitted instead of four plates to every level to achieve similar clinical and radiological outcomes. III. These slides can be retrieved under Electronic Supplementary Material.

  4. Breaking Carbon Lock-in

    DEFF Research Database (Denmark)

    Driscoll, Patrick Arthur

    2014-01-01

    This central focus of this paper is to highlight the ways in which path dependencies and increasing returns (network effects) serve to reinforce carbon lock-in in large-scale road transportation infrastructure projects. Breaking carbon lock-in requires drastic changes in the way we plan future...

  5. Cervical Cap

    Science.gov (United States)

    ... Videos for Educators Search English Español The Cervical Cap KidsHealth / For Teens / The Cervical Cap What's in ... Call the Doctor? Print What Is a Cervical Cap? A cervical cap is a small cup made ...

  6. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  7. Meningocele Cervical. Presentación de un caso Cervical meningocele. A case report

    Directory of Open Access Journals (Sweden)

    Mabel Rita Camejo Macías

    2012-06-01

    Full Text Available El meningocele cervical es una forma rara de disrafismo espinal. La placa neural pasa por diversas transformaciones hasta convertirse en el tubo neural y cualquier alteración durante su cierre conllevará la aparición de la espina bífida. Durante el embarazo las necesidades maternas de folatos aumentan debido a la síntesis de ácidos nucleicos y proteínas durante la embriogénesis, velocidad de crecimiento y desarrollo fetal de los primeros meses de la gestación. Se presenta el caso de paciente masculino de 12 meses de edad, nacido de un parto eutócico institucional ocurrido el día 5 de diciembre del 2008, con una tumoración en la región posterior del cuello al nacer; es remitido al servicio de Neurocirugía del Hospital Mario Catarino Rivas. Se observó como dato positivo en la región cervical un aumento de volumen redondeado, adherido al plano profundo, renitente, movible y no doloroso cubierto de piel en su totalidad. Se le diagnostica un meningocele cervical y confirma mediante resonancia magnética nuclear cervicodorsal. Se realizó la resección del mismo en el mes de febrero del año 2010 y ha sido evaluado periódicamente en las consultas de neurocirugía y en su área de salud con evolución satisfactoria.Cervical meningocele is a rare form of spinal dysrhahism. Neural plate undergoes various transformations to become into the neural tube, and any modifications occurring during the closure, will lead to the onset of spina bifida. During pregnancy the maternal needs of folates increase due to the synthesis of nucleic acids and proteins, all through the embryogenesis, velocity of growth and fetal development in the first months of pregnancy. A 12-months age, male patient, born from a normal delivery, December 5, 2008 at “Santa Barbara” Hospital, presented a tumor at birth in the posterior region of the neck; the patient was referred to the Neurosurgery Service at “Mario Catarino Rivas” Hospital. As positive information

  8. 49 CFR 236.705 - Bar, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Bar, locking. 236.705 Section 236.705..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.705 Bar, locking. A bar in an interlocking machine to which the locking dogs are attached. ...

  9. 49 CFR 236.768 - Locking, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  10. Phase locking between Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1990-01-01

    We report observations of phase-locking phenomena between two Josephson soliton (fluxon) oscillators biased in self-resonant modes. The locking strength was measured as a function of bias conditions. A frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. Two coupled...... perturbed sine-Gordon equations were derived from an equivalent circuit consisting of inductively coupled, nonlinear, lossy transmission lines. These equations were solved numerically to find the locking regions. Good qualitative agreement was found between the experimental results and the calculations...

  11. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    Energy Technology Data Exchange (ETDEWEB)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan, E-mail: lining@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-05-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 mum RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm{sup 2}. The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  12. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    International Nuclear Information System (INIS)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan

    2009-01-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 μm RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm 2 . The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  13. Self-locking degree-4 vertex origami structures.

    Science.gov (United States)

    Fang, Hongbin; Li, Suyi; Wang, K W

    2016-11-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications.

  14. Optical double-locked semiconductor lasers

    Science.gov (United States)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  15. Bicycle Parking and Locking

    DEFF Research Database (Denmark)

    Larsen, Jonas

    2017-01-01

    . This article contributes with new insights into parking and locking - ‘moorings’ - to cycling literature. It presents an ethnography of ‘design moorings’ and practices associated with parking and locking bikes. The main case study is the very pro-cycling city of Copenhagen. Yet to explore what is unique about...

  16. 49 CFR 236.757 - Lock, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  17. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  18. Reduced and selective integration techniques in the finite element analysis of plates

    International Nuclear Information System (INIS)

    Hughes, T.J.R.; Cohen, M.; Haroun, M.

    1978-01-01

    Efforts to develop effective plate bending finite elements by reduced integration techniques are described. The basis for the development is a 'thick' plate theory in which transverse shear strains are accounted for. The variables in the theory are all kinematic, namely, displacements and independent rotations. As only C 0 continuity is required, isoparametric elements may be employed, which result in several advantages over thin plate elements. It is shown that the avoidance of shear 'locking' may be facilitated by reduced integration techniques. Both uniform and selective schemes are considered. Conditions under which selective schemes are invariant are identified, and they are found to have an advantage over uniform schemes in the present situation. It is pointed out that the present elements are not subject to the difficulties encountered by thin plate theory elements, concerning boundary conditions. For example, the polygonal approximation of curved, simply supported edges is convergent. Other topics discussed are the equivalence with mixed methods, rank deficiency, convergence criteria and useful mass 'lumping' schemes for dynamics. Numerical results for several thin plate problems indicate the high degree of accuracy attainable by the present elements. (Auth.)

  19. Cervical spinal canal narrowing and cervical neurologi-cal injuries

    Directory of Open Access Journals (Sweden)

    ZHANG Ling

    2012-04-01

    Full Text Available 【Abstract】Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms in-cluding neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C 1 to C 7 ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C 4 for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (≤14 mm in Whites, ≤ 12 mm in Japanese, ≤13.7 mm in Chinese. Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflam-matory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this re-view will be helpful in diagnosing spinal cord and neuro-logical injuries with the geometric parameters of cervical spine in the future. Key words: Spinal cord injuries; Spinal stenosis; Trauma, nervous system

  20. Pathogenesis of spinal cord involvement induced by lower cervical instability in rheumatoid spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Hironobu; Kuwabara, Shigeru; Fukuda, Kenji; Kuroki, Tatsuji; Tajima, Naoya (Miyazaki Medical Coll., Kiyotake (Japan))

    1994-07-01

    To examine prognostic factors in rheumatoid arthritis (RA), plain radiography findings and magnetic resonance imaging (MRI) findings were compared with histopathological findings in 129 RA patients who had local or neurologic symptoms due to the cervical spine. All patients underwent plain radiography, and subdislocation more than 2 mm towards the anterior and posterior directions on plain radiographs was defined as instability. In predicting induction of instability of the inferior cervical spine and risk for spinal compression, erosion of the vertebral rim, as seen on plain X-rays, and irregular findings of the end-plate of the vertebral body and Gd-enhanced nodules around the intervertebral disk, as seen on MRI, seemed to be important. (N.K.).

  1. Microcontroller-based locking in optics experiments

    International Nuclear Information System (INIS)

    Huang, K.; Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J.

    2014-01-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments

  2. Microcontroller-based locking in optics experiments.

    Science.gov (United States)

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  3. Microcontroller-based locking in optics experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, K. [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France); State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062 (China); Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J., E-mail: julien.laurat@upmc.fr [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France)

    2014-12-15

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  4. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  5. Heterogeneous Silicon III-V Mode-Locked Lasers

    Science.gov (United States)

    Davenport, Michael Loehrlein

    Mode-locked lasers are useful for a variety of applications, such as sensing, telecommunication, and surgical instruments. This work focuses on integrated-circuit mode-locked lasers: those that combine multiple optical and electronic functions and are manufactured together on a single chip. While this allows production at high volume and lower cost, the true potential of integration is to open applications for mode-locked laser diodes where solid state lasers cannot fit, either due to size and power consumption constraints, or where small optical or electrical paths are needed for high bandwidth. Unfortunately, most high power and highly stable mode-locked laser diode demonstrations in scientific literature are based on the Fabry-Perot resonator design, with cleaved mirrors, and are unsuitable for use in integrated circuits because of the difficulty of producing integrated Fabry-Perot cavities. We use silicon photonics and heterogeneous integration with III-V gain material to produce the most powerful and lowest noise fully integrated mode-locked laser diode in the 20 GHz frequency range. If low noise and high peak power are required, it is arguably the best performing fully integrated mode-locked laser ever demonstrated. We present the design methodology and experimental pathway to realize a fully integrated mode-locked laser diode. The construction of the device, beginning with the selection of an integration platform, and proceeding through the fabrication process to final optimization, is presented in detail. The dependence of mode-locked laser performance on a wide variety of design parameters is presented. Applications for integrated circuit mode-locked lasers are also discussed, as well as proposed methods for using integration to improve mode-locking performance to beyond the current state of the art.

  6. Cervical Cancer

    Centers for Disease Control (CDC) Podcasts

    2007-03-06

    Did you know that cervical cancer rates differ by race/ethnicity and region? Or that cervical cancer can usually be prevented if precancerous cervical lesions are found by a Pap test and treated? Find out how getting regular Pap tests can save a woman's life.  Created: 3/6/2007 by National Breast and Cervical Cancer Early Detection Program.   Date Released: 4/25/2007.

  7. 30 CFR 56.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  8. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  9. Computation of the lock-in ranges of phase-locked loops with PI filter

    OpenAIRE

    Aleksandrov, Konstantin D.; Kuznetsov, Nikolay; Leonov, Gennady A.; Neittaanmäki, Pekka; Yuldashev, Marat V.; Yuldashev, Renat V.

    2016-01-01

    In the present work the lock-in range of PLL-based circuits with proportionallyintegrating filter and sinusoidal phase-detector characteristics are studied. Considered circuits have sinusoidal phase detector characteristics. Analytical approach based on the methods of phase plane analysis is applied to estimate the lock-in ranges of the circuits under consideration. Obtained analytical results are compared with simulation results.

  10. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  11. Plate Motion and Crustal Deformation Estimated with Geodetic Data from the Global Positioning System

    Science.gov (United States)

    Argus, Donald F.; Heflin, Michael B.

    1995-01-01

    We use geodetic data taken over four years with the Global Positioning System (GPS) to estimate: (1) motion between six major plates and (2) motion relative to these plates of ten sites in plate boundary zones. The degree of consistency between geodetic velocities and rigid plates requires the (one-dimensional) standard errors in horizontal velocities to be approx. 2 mm/yr. Each of the 15 angular velocities describing motion between plate pairs that we estimate with GPS differs insignificantly from the corresponding angular velocity in global plate motion model NUVEL-1A, which averages motion over the past 3 m.y. The motion of the Pacific plate relative to both the Eurasian and North American plates is observed to be faster than predicted by NUVEL-1A, supporting the inference from Very Long B ase- line Interferometry (VLBI) that motion of the Pacific plate has speed up over the past few m.y. The Eurasia-North America pole of rotation is estimated to be north of NUVEL-1A, consistent with the independent hypothesis that the pole has recently migrated northward across northeast Asia to near the Lena River delta. Victoria, which lies above the main thrust at the Cascadia subduction zone, moves relative to the interior of the overriding plate at 30% of the velocity of the subducting plate, reinforcing the conclusion that the thrust there is locked beneath the continental shelf and slope.

  12. Block-like plate movements in eastern Anatolia observed by InSAR

    KAUST Repository

    Cavalie, Olivier

    2014-01-16

    The question whether continental plates deform internally or move as rigid blocks has been debated for several decades. To further address this question, we use large-scale interferometric synthetic aperture radar (InSAR) data sets to study how eastern Anatolia and its surrounding plates deform. We find that most of the deformation is focused at the North and East Anatolian faults and little intraplate deformation takes place. Anatolia is therefore moving, at least its eastern part, as a uniform block. We estimate the slip velocity and locking depth of the North Anatolian fault at this location to be 20 mm/yr and ~14 km, respectively. High deformation gradient found near the East Anatolian fault, on the other hand, suggests that little stress is accumulating along the eastern sections of that fault.

  13. Does rehabilitation of cervical lordosis influence sagittal cervical spine flexion extension kinematics in cervical spondylotic radiculopathy subjects?

    Science.gov (United States)

    Moustafa, Ibrahim Moustafa; Diab, Aliaa Attiah Mohamed; Hegazy, Fatma A; Harrison, Deed E

    2017-01-01

    To test the hypothesis that improvement of cervical lordosis in cervical spondylotic radiculopathy (CSR) will improve cervical spine flexion and extension end range of motion kinematics in a population suffering from CSR. Thirty chronic lower CSR patients with cervical lordosis lordosis (p lordosis in the study group was associated with significant improvement in the translational and rotational motions of the lower cervical spine. This finding provides objective evidence that cervical flexion/extension is partially dependent on the posture and sagittal curve orientation. These findings are in agreement with several other reports in the literature; whereas ours is the first post treatment analysis identifying this relationship.

  14. A novel mode-locking technique

    International Nuclear Information System (INIS)

    Chen Shaoh; Chen Youming; Chen Taolue; Si Xiangdong; Yang Yi; Deng Ximing

    1993-01-01

    A novel mode-locked Nd:YAG oscillator has been developed by using an ultrafast photoconductive feedback controlled loop, and mode-locked pulses with a duration of 100ps have been obtained. The energy instability of the pulse trains is ±5%. In this type of mode-locking technology, a type of deep-level doped GaAs (Cr-doped) photoconductive switch, which has a fast response in time and is free of avalance process, is used to drive a Pockels' cell to realize mode-locking. The dark resistance of this type of photoconductive switch is 6 orders of magnitude higher than that of the intrinsic single-crystal silicon, and it can reach a level as high as 10 9 ohms. Consequently, it is able to withstand longterm operation at several thousand DC volts. By means of the photoconductive ohmic switch characteristics, the authors have designed a positive feedback control network which has a very fast response time, and can couple a voltage of up to a thousand volts. Using this unit in a Nd:YAG laser, they have successfully realized a very stable mode-locked pulse train with pulse width shorter than 100 ps. The operation principle, and the results of the preliminary experiments are presented here. 1 ref., 3 figs

  15. Avaliação do tratamento da discopatia degenerativa cervical pela artrodese via anterior utilizando placas associadas a cages ou cages em peek isoladamente Evaluación del tratamiento de la enfermedad degenerativa del disco cervical por la artrodesis anterior utilizando placas asociadas con jaulas o jaulas en peec, aisladamente Evaluation of cervical degenerative disc disease treatment by anterior arthrodesis using plates associated with cages or cages in peek alone

    Directory of Open Access Journals (Sweden)

    André Rafael Hübner

    2011-01-01

    por el método de fijación con placas asociadas a jaulas - Grupo I - y 35 con las jaulas en PEEK, aisladamente - Grupo II. Se recolectarondatos de historial clínico, examen físico, puntuaciones de dolor (escala visual y analógica del dolor-EVA y función (criterios de Odom, SF-36, Índice de Discapacidad Cervical del pre y posoperatorio y exámenes de imagen. RESULTADOS: Se encontró un predominio de pacientes de sexo femenino en ambos grupos, con una edad promediode 55 años en el Grupo I y de 47 en el Grupo II. Ambos grupos mostraron una distribución similar en el número de niveles operados, así como de las complicaciones encontradas y de las puntuaciones de dolor, índice de discapacidad cervical y SF36 para el pre y posoperatorio. Hubo 97,1% para la fusión y 94,3% de buenos resultados en el Grupo I y el 100% de fusión, con 97% de buenos resultados en el Grupo II. CONCLUSIONES: El estudio comparativo de la utilización de placas con jaulas y estas en PEEK, aisladamente, presentó resultados similares y satisfactorios para los grupos estudiados, sin mostrar superioridad o inferioridad de un método sobre otro.OBJECTIVES: To comparatively evaluate the treatment of cervical degenerative disc disease by anterior approach using plates associated or cages and PEEK device alone. METHODS: A retrospective study comparing two groups of patients treated by anterior arthrodesis was performed. Seventy patients were randomly selected, 35 operated using plates associated with cages - Group I - and 35 with cages in PEEK alone - Group II. Medical history was obtained as well as physical examination, pain scores (pain visual analogue score and function scores (Odom's criteria, SF-36, Neck Disability Index and the pre and postoperative imaging studies. RESULTS: There was a predominance of female patients in both groups, with a mean age of 55 years in Group I and 47 in Group II. Both groups showed a similar distribution of the number of levels operated, as well as the

  16. Power spectrum of an injection-locked Josephson oscillator

    International Nuclear Information System (INIS)

    Stancampiano, C.V.; Shapiro, S.

    1975-01-01

    Experiments have shown that a Josephson oscillator, exposed to a weak narrow-band input signal, exhibits behavior characteristic of an injection-locked oscillator. When in lock, Adler's theory of injection locking describes the experimental observations reasonably well. The range of applicability of the theory is extended to the out-of-lock regime where a spectrum of output frequencies is observed. Obtaining the theoretical output power spectrum requires solving a differential equation having the same form as the equation describing the resistively shunted junction model of Stewart and of McCumber. Experimental measurements of the output spectrum of a nearly locked Josephson oscillator are shown to be in reasonable agreement with the theory. Additional results discussed briefly include the observation of a frequency dependence of the locked Josephson oscillator output and experiments in which a Josephson oscillator-mixer was injection locked by a weak signal at the rf

  17. Cervical Cap

    Science.gov (United States)

    ... giving birth vaginally, which means the cervical cap may not fit as well. Inconsistent or incorrect use of the cervical cap increases your risk of pregnancy. For example, you may get pregnant when using the cervical cap if: ...

  18. The variable finesse locking technique

    International Nuclear Information System (INIS)

    Acernese, F; Al-Shourbagy, M

    2006-01-01

    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

  19. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    Science.gov (United States)

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  20. MINIMAL INVASIVE PLATE OSTEOSYNTHESIS- AN EFFECTIVE TREATMENT METHOD FOR DISTAL TIBIA INTRAARTICULAR (PILON FRACTURES- AN 18 MONTHS FOLLOW UP

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND Tibial pilon fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable, because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and Minimally Invasive Plate Osteosynthesis (MIPO for distal tibia has emerged as an alternative treatment option because it respects fracture biology and haematoma and also provides biomechanically stable construct. The aim of the study is to evaluate the results of minimally invasive plate osteosynthesis using locking plates in treating tibial pilon fractures in terms of fracture union, restoration of ankle function and complications. MATERIALS AND METHODS 30 patients with closed tibial pilon fractures (Ruedi and Allgower type I (14, type II (13, type III (3 treated with MIPO with Locking Compression Plates (LCP were prospectively followed for average duration of 18 months. RESULTS Average duration of injury-hospital and injury-surgery interval was as 12.05 hrs. and 3.50 days, respectively. All fractures got united with an average duration of 20.8 weeks (range 14-28 weeks. Olerud and Molander score was used for evaluation at 3 months, 6 months and 18 months. One patient had union with valgus angulation of 15 degrees, but no nonunion was found. CONCLUSION The present study shows that MIPO with LCP is an effective treatment method in terms of union time and complications rate for tibial pilon fracture promoting early union and early weight bearing.

  1. Cervical Myomas

    Science.gov (United States)

    ... Adnexal Torsion Bartholin Gland Cysts Cervical Myomas Cervical Stenosis Endometriomas of the Vulva Inclusion and Epidermal Cysts of the Vulva Noncancerous Ovarian Growths Polyps of the Cervix Skene Duct Cyst Cervical myomas are smooth, benign tumors in the cervix. A myoma may bleed, ...

  2. Hersendood. Mackies leibniziaanse herinterpretatie van Lockes theorie van persoonsidentiteit

    OpenAIRE

    De Vleeschouwer, Gregory

    2009-01-01

    In his book, 'Problems from Locke', John Leslie Mackie presents a theory of personal identity (pi) that is meant to be a supplement and correction of Locke's pi-theory. In a first part I introduce the criterion of pi that was standard before Locke's pi-theory. By showing in a second part how Locke reacted against this traditional criterion, I show wherein the singularity of Locke's pi-theory exists. In a third part I explain how Leibniz is moved by the same solicitude as Locke, but also how h...

  3. Surgical management of metastatic tumors of the cervical spine.

    Science.gov (United States)

    Davarski, Atanas N; Kitov, Borislav D; Zhelyazkov, Christo B; Raykov, Stefan D; Kehayov, Ivo I; Koev, Ilyan G; Kalnev, Borislav M

    2013-01-01

    To present the results from the clinical presentation, the imaging diagnostics, surgery and postoperative status of 17 patients with cervical spine metastases, to analyse all data and make the respective conclusions and compare them with the available data in the literature. The study analysed data obtained by patients with metastatic cervical tumours treated in St George University Hospital over a period of seven years. All patients underwent diagnostic imaging tests which included, separately or in combination, cervical x-rays, computed tomography scan and magnetic-resonance imaging. Severity of neurological damage and its pre- and postoperative state was graded according to the Frankel Scale. For staging and operating performance we used the Tomita scale and Harrington classification. Seven patients had only one affected vertebra, 4 patients--two vertebrae, one patient--three vertebrae, 2 patients--four vertebrae, and in the other 3 patients more than one segment was affected. Surgery was performed in 12 patients. One level anterior corpectomy was performed in 6 patients, three patients had two-level surgery, and one patient--three-level corpectomy; in the remaining 2 cases we used posterior approach in surgery. Complete corpectomy was performed in 4 patients, subtotal corpectomy was used in 6 patients and partial--in 2 patients. Anterior stabilization system ADD plus (Ulrich GmbH & Co. KG, Ulm, Germany) was implanted in 2 patients; in 8 patients anterior titanium plate and bone graft were used, and in 1 patient--posterior cervical stabilization system. Because of the pronounced pain syndrome and frequent neurological lesions as a result of the cervical spine metastases use of surgery is justified. The main purpose is to maximize tumor resection, achieve optimal spinal cord and nerve root decompression and stabilize the affected segment.

  4. Cervical Spondylosis and Hypertension

    Science.gov (United States)

    Peng, Baogan; Pang, Xiaodong; Li, Duanming; Yang, Hong

    2015-01-01

    Abstract Cervical spondylosis and hypertension are all common diseases, but the relationship between them has never been studied. Patients with cervical spondylosis are often accompanied with vertigo. Anterior cervical discectomy and fusion is an effective method of treatment for cervical spondylosis with cervical vertigo that is unresponsive to conservative therapy. We report 2 patients of cervical spondylosis with concomitant cervical vertigo and hypertension who were treated successfully with anterior cervical discectomy and fusion. Stimulation of sympathetic nerve fibers in pathologically degenerative disc could produce sympathetic excitation, and induce a sympathetic reflex to cause cervical vertigo and hypertension. In addition, chronic neck pain could contribute to hypertension development through sympathetic arousal and failure of normal homeostatic pain regulatory mechanisms. Cervical spondylosis may be one of the causes of secondary hypertension. Early treatment for resolution of symptoms of cervical spondylosis may have a beneficial impact on cardiovascular disease risk in patients with cervical spondylosis. PMID:25761188

  5. Two-level cervical corpectomy-long-term follow-up reveals the high rate of material failure in patients, who received an anterior approach only.

    Science.gov (United States)

    Bayerl, Simon Heinrich; Pöhlmann, Florian; Finger, Tobias; Prinz, Vincent; Vajkoczy, Peter

    2018-06-18

    In contrast to a one-level cervical corpectomy, a multilevel corpectomy without posterior fusion is accompanied by a high material failure rate. So far, the adequate surgical technique for patients, who receive a two-level corpectomy, remains to be elucidated. The aim of this study was to determine the long-term clinical outcome of patients with cervical myelopathy, who underwent a two-level corpectomy. Outcome parameters of 21 patients, who received a two-level cervical corpectomy, were retrospectively analyzed concerning reoperations and outcome scores (VAS, Neck Disability Index (NDI), Nurick scale, modified Japanese Orthopaedic Association score (mJOAS), Short Form 36-item Health Survey Questionnaire (SF-36)). The failure rate was determined using postoperative radiographs. The choice over the surgical procedures was exercised by every surgeon individually. Therefore, a distinction between two groups was possible: (1) anterior group (ANT group) with a two-level corpectomy and a cervical plate, (2) anterior/posterior group (A/P group) with two-level corpectomy, cervical plate, and additional posterior fusion. Both groups benefitted from surgery concerning pain, disability, and myelopathy. While all patients of the A/P group showed no postoperative instability, one third of the patients of the ANT group exhibited instability and clinical deterioration. Thus, a revision surgery with secondary posterior fusion was needed. Furthermore, the ANT group had worse myelopathy scores (mJOAS ANT group  = 13.5 ± 2.5, mJOAS A/P group  = 15.7 ± 2.2). Patients with myelopathy, who receive a two-level cervical corpectomy, benefitted from surgical decompression. However, patients with a sole anterior approach demonstrated a very high rate of instability (33%) and clinical deterioration in a long-term follow-up. Therefore, we recommend to routinely perform an additional posterior fusion after two-level cervical corpectomy.

  6. Angular-stable locking plate fixation of tibial plateau fractures-clinical and radiological midterm results in 101 patients

    OpenAIRE

    Sven Mardian; Felix Landmann; Florian Wichlas; Norbert P Haas; Klaus-Dieter Schaser; Philipp Schwabe

    2015-01-01

    Background: Articular reconstruction and stable fixation of tibial plateau fractures and its various subtypes continue to represent a surgical challenge. Only few trials have studied results following angular stable plate fixation. The present study aimed to investigate the clinical, radiological, functional and quality of life results following tibial plateau fractures using angular stable plate fixation. Materials and Methods: 101 patients were retrospectively studied using functional (...

  7. Brain communication in the locked-in state.

    Science.gov (United States)

    De Massari, Daniele; Ruf, Carolin A; Furdea, Adrian; Matuz, Tamara; van der Heiden, Linda; Halder, Sebastian; Silvoni, Stefano; Birbaumer, Niels

    2013-06-01

    Patients in the completely locked-in state have no means of communication and they represent the target population for brain-computer interface research in the last 15 years. Although different paradigms have been tested and different physiological signals used, to date no sufficiently documented completely locked-in state patient was able to control a brain-computer interface over an extended time period. We introduce Pavlovian semantic conditioning to enable basic communication in completely locked-in state. This novel paradigm is based on semantic conditioning for online classification of neuroelectric or any other physiological signals to discriminate between covert (cognitive) 'yes' and 'no' responses. The paradigm comprised the presentation of affirmative and negative statements used as conditioned stimuli, while the unconditioned stimulus consisted of electrical stimulation of the skin paired with affirmative statements. Three patients with advanced amyotrophic lateral sclerosis participated over an extended time period, one of which was in a completely locked-in state, the other two in the locked-in state. The patients' level of vigilance was assessed through auditory oddball procedures to study the correlation between vigilance level and the classifier's performance. The average online classification accuracies of slow cortical components of electroencephalographic signals were around chance level for all the patients. The use of a non-linear classifier in the offline classification procedure resulted in a substantial improvement of the accuracy in one locked-in state patient achieving 70% correct classification. A reliable level of performance in the completely locked-in state patient was not achieved uniformly throughout the 37 sessions despite intact cognitive processing capacity, but in some sessions communication accuracies up to 70% were achieved. Paradigm modifications are proposed. Rapid drop of vigilance was detected suggesting attentional

  8. Cervical Cancer

    Centers for Disease Control (CDC) Podcasts

    Did you know that cervical cancer rates differ by race/ethnicity and region? Or that cervical cancer can usually be prevented if precancerous cervical lesions are found by a Pap test and treated? Find out how getting regular Pap tests can save a woman's life.

  9. Cervical Vertigo(Vertigo)

    OpenAIRE

    本間, 隆夫; Homma, Takao

    1992-01-01

    Cervical vertigo was reviewed as to its mechanism, diagnosis and treatment, and nine cases which had operation done were briefly presented. Cervical vertigo has been seen occasionaly in the cases of cervical spondylosis, frequently in the cases of traumatic cervical syndrome. The mechanism is attributed to either vertebrobasilar insufficiency caused by compression on vertebral artery or irritation of poterior cervical sympathetic system. The diagnosis consists of reccurent vertigo attack with...

  10. Locked modes and magnetic field errors in MST

    International Nuclear Information System (INIS)

    Almagri, A.F.; Assadi, S.; Prager, S.C.; Sarff, J.S.; Kerst, D.W.

    1992-06-01

    In the MST reversed field pinch magnetic oscillations become stationary (locked) in the lab frame as a result of a process involving interactions between the modes, sawteeth, and field errors. Several helical modes become phase locked to each other to form a rotating localized disturbance, the disturbance locks to an impulsive field error generated at a sawtooth crash, the error fields grow monotonically after locking (perhaps due to an unstable interaction between the modes and field error), and over the tens of milliseconds of growth confinement degrades and the discharge eventually terminates. Field error control has been partially successful in eliminating locking

  11. Shareholder Lock-In Contracts : Share Price and Trading Volume Effects at the Lock-In Expiry

    NARCIS (Netherlands)

    Angenandt, P.P.; Goergen, M.; Renneboog, L.D.R.

    2005-01-01

    This paper unveils the diversity in lock-in agreements of firms listed on the Nouveau Marche stock exchange in France.We give the main economic reasons why shareholders adopt lock-in agreements that are more stringent than legally required.We relate the abnormal returns and the abnormal volume at

  12. Cervical Spondylosis and Hypertension

    OpenAIRE

    Peng, Baogan; Pang, Xiaodong; Li, Duanming; Yang, Hong

    2015-01-01

    Abstract Cervical spondylosis and hypertension are all common diseases, but the relationship between them has never been studied. Patients with cervical spondylosis are often accompanied with vertigo. Anterior cervical discectomy and fusion is an effective method of treatment for cervical spondylosis with cervical vertigo that is unresponsive to conservative therapy. We report 2 patients of cervical spondylosis with concomitant cervical vertigo and hypertension who were treated successfully w...

  13. Cervicitis

    Science.gov (United States)

    ... that does not go away: discharge may be gray, white or yellow in color Painful sexual intercourse ... Names Cervical inflammation; Inflammation - cervix Images Female reproductive anatomy Cervicitis Uterus References Eckert LO, Lentz GM. Infections ...

  14. Geodesy cannot presently detect the up-dip limit of frictional locking on megathrusts

    Science.gov (United States)

    Almeida, R. V.; Lindsey, E. O.; Bradley, K.; Hubbard, J.; Sathiakumar, S.; Malick, R.; Hill, E.

    2017-12-01

    Most discussions of interseismic behavior on megathrust faults focus on whether they are frictionally locked or creeping. Unfortunately, many geodetic studies of subduction zone megathrusts equate fault coupling with frictional locking. This comparison is not appropriate, as one reflects the physical properties of the fault, and the other reflects the kinematics of the fault. Much of the uncertainty about slip behavior is because in subduction zones, the shallow part of the fault is far from land, and therefore creep is not detectable by land-based GPS. Published coupling maps of subduction zone megathrusts often assume a low coupling ratio near the trench, updip from fully coupled regions. Yet, if the megathrust attains a coupling ratio of 1 anywhere on the fault (i.e., the hanging wall is moving with the same velocity as the footwall), a lower value of coupling updip of this location requires interseismic extension at a rate proportional to the decrease (Wang and Dixon, 2004). We argue that the shallow region of megathrusts lie in updip stress shadows, and do not (except under rare circumstances) experience appropriate driving forces to cause significant creep during the interseismic period. Therefore it may not be possible to determine whether these regions are frictionally locked by examining interseismic geodetic records. We demonstrate this effect using a boundary element model with rate-strengthening friction and a simplified subduction zone geometry. We show that a coupling value of zero at the trench is physically unrealistic even if only a small portion of the downdip fault zone is locked. The maximum creep at the trench depends on the width of the transition of the frictionally locked zone, but should be small (<30% of plate rate) under most circumstances. During the interseismic period, even if the shallow parts of megathrusts are frictionally unlocked, creep is likely smaller than the resolution of current seafloor geodetic techniques (which is

  15. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-12-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  16. Universal spin-momentum locked optical forces

    Energy Technology Data Exchange (ETDEWEB)

    Kalhor, Farid [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Thundat, Thomas [Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Jacob, Zubin, E-mail: zjacob@purdue.edu [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Birck Nanotechnology Center, Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47906 (United States)

    2016-02-08

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, the direction of decay, and the direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and HE{sub 11} mode of an optical fiber. Furthermore, we explain how the recently reported phenomena of lateral optical force on chiral and achiral particles are caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from the well-known orbital angular momentum of light. Our work presents a unified view on spin-momentum locking and how it affects optical forces on chiral and achiral particles.

  17. Multiprocessor Real-Time Locking Protocols for Replicated Resources

    Science.gov (United States)

    2016-07-01

    assignment problem, the ac- tual identities of the allocated replicas must be known. When locking protocols are used, tasks may experience delays due to both...Multiprocessor Real-Time Locking Protocols for Replicated Resources ∗ Catherine E. Jarrett1, Kecheng Yang1, Ming Yang1, Pontus Ekberg2, and James H...replicas to execute. In prior work on replicated resources, k-exclusion locks have been used, but this restricts tasks to lock only one replica at a time. To

  18. Get Tested for Cervical Cancer

    Science.gov (United States)

    ... Print This Topic En español Get Tested for Cervical Cancer Browse Sections The Basics Overview Cervical Cancer Cervical ... Cervical Cancer 1 of 5 sections The Basics: Cervical Cancer What is cervical cancer? Cervical cancer is cancer ...

  19. Locking of intrinsic angular momentum in collision complexes

    International Nuclear Information System (INIS)

    Berengolts, Alexander.

    1995-04-01

    A concept of locking of the intrinsic angular momentum of a fragment of a collision complex to a body-fixed axis is widely used in the description of heavy-particle dynamics. The aim of this work is to provide a semiclassical description of the locking phenomenon which occur in diatomic and three atomic collision complexes. The first part of this work is devoted to the semiclassical study of the locking of the electronic angular momentum that occurs in slow collisions of two atoms, one in the spherically symmetric state and the other in state with j= 1. Here we calculate explicitly the complete locking matrix for different types of interatomic interactions. The elements of this matrix directly enter into the semiclassical expression for the different cross sections of polarized atoms. Limitations to the notion of the the locking radius and slipping probability are discussed in connection with the steepness of the interaction. Numerical calculations confirm analytical result: the optimal criterion for determination of the locking radius is a condition for the accumulated phase difference between two molecular states. Analytical expressions are suggested for the locking angle and the slipping probability. Implication of the locking approximation for calculation of the quasiclassical scattering matrix is discussed. The second part considers the locking of the rotational angular momentum of a diatom in the decomposition of a triatomic complexes. We discuss here cases J = 1,2,3 and 4, but restrict ourselves to calculation of the so-called dynamic orientation of the diatomic fragment. The letter represents one of the characteristics of the locking matrix which in principle can be measured experimentally. The orientation is created as a result of the interplay between the adiabatic interaction in the atom- diatom exit channel and the rotationally non adiabatic coupling in the perturbed rotor region

  20. Injection locking of optomechanical oscillators via acoustic waves.

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-02

    Injection locking is an effective technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators. As such, exploring new mechanisms for injection locking of emerging oscillators is important for their usage in various systems. Here, we present the first demonstration of injection locking of a radiation pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can be easily implemented on various platforms to lock different types of OMOs independent of their size and structure. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance, matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity, and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology, and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  1. January Monthly Spotlight: Cervical Health and Cervical Cancer Disparities

    Science.gov (United States)

    In January, CRCHD joins the nation in raising awareness for Cervical Health and Cervical Cancer Disparities. This month we share a special focus on NCI/CRCHD research programs that are trying to reduce cervical cancer disparities in underserved communities and the people who are spreading the word about the importance of early detection.

  2. No Snowball on Habitable Tidally Locked Planets

    Science.gov (United States)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  3. No Snowball on Habitable Tidally Locked Planets

    International Nuclear Information System (INIS)

    Checlair, Jade; Abbot, Dorian S.; Menou, Kristen

    2017-01-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO 2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  4. Numerical and experimental study of bistable plates for morphing structures

    Science.gov (United States)

    Nicassio, F.; Scarselli, G.; Avanzini, G.; Del Core, G.

    2017-04-01

    This study is concerned with the activation energy threshold of bistable composite plates in order to tailor a bistable system for specific aeronautical applications. The aim is to explore potential configurations of the bistable plates and their dynamic behavior for designing novel morphing structure suitable for aerodynamic surfaces and, as a possible further application, for power harvesters. Bistable laminates have two stable mechanical shapes that can withstand aerodynamic loads without additional constraint forces or locking mechanisms. This kind of structures, when properly loaded, snap-through from one stable configuration to another, causing large strains that can also be used for power harvesting scopes. The transition between the stable states of the composite laminate can be triggered, in principle, simply by aerodynamic loads (pilot, disturbance or passive inputs) without the need of servo-activated control systems. Both numerical simulations based on Finite Element models and experimental testing based on different activating forcing spectra are used to validate this concept. The results show that dynamic activation of bistable plates depend on different parameters that need to be carefully managed for their use as aircraft passive wing flaps.

  5. Commonwealth Edison Company pressure locking test report

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.; Kelly, J.F.

    1996-12-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology.

  6. Commonwealth Edison Company pressure locking test report

    International Nuclear Information System (INIS)

    Bunte, B.D.; Kelly, J.F.

    1996-01-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology

  7. Impact of Isometric Contraction of Anterior Cervical Muscles on Cervical Lordosis.

    Science.gov (United States)

    Fedorchuk, Curtis A; McCoy, Matthew; Lightstone, Douglas F; Bak, David A; Moser, Jacque; Kubricht, Brett; Packer, John; Walton, Dustin; Binongo, Jose

    2016-09-01

    This study investigates the impact of isometric contraction of anterior cervical muscles on cervical lordosis. 29 volunteers were randomly assigned to an anterior head translation (n=15) or anterior head flexion (n=14) group. Resting neutral lateral cervical x-rays were compared to x-rays of sustained isometric contraction of the anterior cervical muscles producing anterior head translation or anterior head flexion. Paired sample t-tests indicate no significant difference between pre and post anterior head translation or anterior head flexion. Analysis of variance suggests that gender and peak force were not associated with change in cervical lordosis. Chamberlain's to atlas plane line angle difference was significantly associated with cervical lordosis difference during anterior head translation (p=0.01). This study shows no evidence that hypertonicity, as seen in muscle spasms, of the muscles responsible for anterior head translation and anterior head flexion have a significant impact on cervical lordosis.

  8. Cervical interfacet spacers and maintenance of cervical lordosis.

    Science.gov (United States)

    Tan, Lee A; Straus, David C; Traynelis, Vincent C

    2015-05-01

    OBJECT The cervical interfacet spacer (CIS) is a relatively new technology that can increase foraminal height and area by facet distraction. These offer the potential to provide indirect neuroforaminal decompression while simultaneously enhancing fusion potential due to the relatively large osteoconductive surface area and compressive forces exerted on the grafts. These potential benefits, along with the relative ease of implantation during posterior cervical fusion procedures, make the CIS an attractive adjuvant in the management of cervical pathology. One concern with the use of interfacet spacers is the theoretical risk of inducing iatrogenic kyphosis. This work tests the hypothesis that interfacet spacers are associated with loss of cervical lordosis. METHODS Records from patients undergoing posterior cervical fusion at Rush University Medical Center between March 2011 and December 2012 were reviewed. The FacetLift CISs were used in all patients. Preoperative and postoperative radiographic data were reviewed and the Ishihara indices and cervical lordotic angles were measured and recorded. Statistical analyses were performed using STATA software. RESULTS A total of 64 patients were identified in whom 154 cervical levels were implanted with machined allograft interfacet spacers. Of these, 15 patients underwent anterior-posterior fusions, 4 underwent anterior-posterior-anterior fusions, and the remaining 45 patients underwent posterior-only fusions. In the 45 patients with posterior-only fusions, a total of 110 levels were treated with spacers. There were 14 patients (31%) with a single level treated, 16 patients (36%) with two levels treated, 5 patients (11%) with three levels treated, 5 patients (11%) with four levels treated, 1 patient (2%) with five levels treated, and 4 patients (9%) with six levels treated. Complete radiographic data were available in 38 of 45 patients (84%). On average, radiographic follow-up was obtained at 256.9 days (range 48-524 days

  9. Wall locking and multiple nonlinear states of magnetic islands

    International Nuclear Information System (INIS)

    Persson, Mikael; Australian National Univ., Canberra, ACT

    1994-01-01

    The nonlinear evolution of magnetic islands is analysed in configurations with multiple resonant magnetic surfaces. The existence of multiple nonlinear steady states, is discussed. These are shown to be associated with states where the dynamics around the different rational surfaces are coupled or decoupled and in the presence of a wall of finite resistivity may correspond wall-locked or non-wall-locked magnetic islands. For the case of strong wall stabilization the locking is shown to consist of two different phases. During the first phase the locking of the plasma at the different rational surfaces occurs. Only when the outermost resonant magnetic surface has locked to the inner surfaces can the actual wall locking process take place. Consequently, wall locking, of a global mode, involving more than one rational surface, can be prevented by the decoupling of the resonant magnetic surfaces by plasma rotation. Possible implications on tokamak experiments are discussed. (author)

  10. A layer-wise MITC9 finite element for the free-vibration analysis of plates with piezo-patches

    Directory of Open Access Journals (Sweden)

    Maria Cinefra

    2015-04-01

    Full Text Available The present article considers the free-vibration analysis of plate structures with piezoelectric patches by means of a plate finite element with variable through-the-thickness layer-wise kinematic. The refined models used are derived from Carrera’s Unified Formulation (CUF and they permit the vibration modes along the thickness to be accurately described. The finite-element method is employed and the plate element implemented has nine nodes, and the mixed interpolation of tensorial component (MITC method is used to contrast the membrane and shear locking phenomenon. The related governing equations are derived from the principle of virtual displacement, extended to the analysis of electromechanical problems. An isotropic plate with piezoelectric patches is analyzed, with clamped-free boundary conditions and subjected to open- and short-circuit configurations. The results, obtained with different theories, are compared with the higher-order type solutions given in the literature. The conclusion is reached that the plate element based on the CUF is more suitable and efficient compared to the classical models in the study of multilayered structures embedding piezo-patches.

  11. No Snowball on Habitable Tidally Locked Planets

    Energy Technology Data Exchange (ETDEWEB)

    Checlair, Jade; Abbot, Dorian S. [Department of the Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, IL 60637 (United States); Menou, Kristen, E-mail: jadecheclair@uchicago.edu [Centre for Planetary Sciences, Department of Physical and Environmental Sciences, University of Toronto at Scarborough, Toronto, ON M1C 1A4 (Canada)

    2017-08-20

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO{sub 2} outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  12. Cervical syphilitic lesions mimicking cervical cancer: a rare case report

    Directory of Open Access Journals (Sweden)

    Xiaoqing Zhu

    2015-02-01

    Full Text Available A woman presented to the hospital due to postcoital vaginal bleeding. The patient was initially diagnosed with cervical carcinoma by clinicians at a local hospital. However, a biopsy of the cervical lesions revealed chronic inflammation and erosion of the cervical mucosa, and the rapid plasma reagin ratio titer was 1:256. The patient was eventually diagnosed with syphilitic cervicitis and treated with minocycline 0.1 g twice a day. The patient was cured with this treatment.

  13. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  14. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  15. Nuclear reactor incorporating locking device for threaded bolt connections

    International Nuclear Information System (INIS)

    Blaushild, R.M.

    1987-01-01

    A nuclear reactor having a pressure vessel and a first element is described comprising a core barrel situated within the pressure vessel. The core barrel has a baffle former secured in and to the core barrel by bolted connections, and a second element comprising baffle plates secured to the inner surface of the baffle former by bolted connections, with a locking device to prevent loosening of bolted connections between the baffle former and at least one of the elements. The baffle former and at least one element are held together by a headed, threaded bolt engaged in a bore coaxially extending in the baffle former and at least one element and threadedly engaged in a threaded section in at least the baffle former. The threaded section has first threaded of a first direction, with the head of the bolt engaged with a shoulder about the bore in at least one element to hold the baffle formed and at least one element together, the head of the bolt having a first diameter and a cavity, having an unsymmetrical wall thereabout, in the end surface thereof. It comprises a recess in at least one element coaxial with the bore forming a wall thereabout and extending inwardly from the outer surface of at least one element, the recess having a second diameter greater than the first diameter, with at least one element having second threads in the wall of a direction opposite the direction of the first threads of the threaded bore; a locking nut having a base with a downwardly depending cylindrical wall thereabout

  16. [The Extended Deltoid-Split Approach for Plating Four-Part Proximal Humeral Fractures].

    Science.gov (United States)

    Schiffer, G; Sayar, A; Thelen, U

    2016-08-01

    The deltoideopectoral approach is established as the gold standard in the surgical treatment of proximal humeral fractures. As an alternative, we demonstrate the extended deltoid approach with an intraoperative video. A direct lateral incision is performed and the anterior parts of the axillary nerve are identified and preserved. In our experience, this approach allows improved visualisation of the greater tuberosity and easier positioning of locking plates. Clinically relevant neurological injuries cannot be seen in our patients or in the literature. Georg Thieme Verlag KG Stuttgart · New York.

  17. Investigation on Locking and Pulling Modes in Analog Frequency Dividers

    Directory of Open Access Journals (Sweden)

    Antonio Buonomo

    2013-01-01

    Full Text Available We compare the main analytical results available to estimate the locking range, which is the key figure-of-merit of LC frequency dividers based on the injection locking phenomenon. Starting from the classical result by Adler concerning injection-locked oscillators, we elucidate the merits and the shortcomings of the different approaches to study injection-locked frequency dividers, with particular emphasis on divider-by-2. In particular, we show the potential of a perturbation approach which enables a more complete analysis of frequency dividers, making it possible to calculate not only the amplitude and the phase of the locked oscillation, but also the region where it exists and is stable, which defines the locking region. Finally, we analyze the dynamical behaviour of the dividers in the vicinity of the boundary of the locking region, showing that there exists a border region where the occurrence of the locking or the pulling operation mode is possible, depending on the initial conditions of the system.

  18. Avaliação retrospectiva de artrodese cervical com enxerto autólogo versus hidroxiapatita Estudio retrospectivo de la artrodesis cervical con autoinjerto versus hidroxiapatita Retrospective study of cervical arthrodesis with autograft versus hydroxyapatite graft

    Directory of Open Access Journals (Sweden)

    Yoshinobu Nagasse

    2010-12-01

    ña serie de casos no hubo diferencias significativas entre los resultados de la fusión cervical anterior con injerto de hidroxiapatita en comparación con injerto autólogo ilíaca.OBJECTIVE: the authors carried out a study to compare the radiografic result in the use of hydroxyapatite graft and iliac crest bone graft (autologous in the surgical treatment of cervical discal herniation in one level, and a cervical arthrodesis was carried out previously with plate. METHODS: a retrospective study with patients who were submitted to cervical artrodesis, comparing two groups of ten patients: one in which the hydroxyapatite graft was used and the other in which the autologous iliac crestwas used. Postoperative x-rays were measured and compared, in search for losses of angular alignment. RESULTS: the two types of grafts demonstrated an alignment in similar rates, with consolidation in all patients. The study did not show fragmentation of the hydroxyapatite graft or acquittal of the synthesis material. CONCLUSION: in this small series of cases, no significant difference was observed between the results of the anterior cervical arthrodesis with hydroxyapatite graft in relation to the iliac crest bone graft.

  19. Is the cervical spine clear? Undetected cervical fractures diagnosed only at autopsy.

    Science.gov (United States)

    Sweeney, J F; Rosemurgy, A S; Gill, S; Albrink, M H

    1992-10-01

    Undetected cervical-spine injuries are a nemesis to both trauma surgeons and emergency physicians. Radiographic protocols have been developed to avoid missing cervical-spine fractures but are not fail-safe. Three case reports of occult cervical fractures documented at autopsy in the face of normal cervical-spine radiographs and computerized tomography scans are presented.

  20. Improving greater trochanteric reattachment with a novel cable plate system.

    Science.gov (United States)

    Baril, Yannick; Bourgeois, Yan; Brailovski, Vladimir; Duke, Kajsa; Laflamme, G Yves; Petit, Yvan

    2013-03-01

    Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement. The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles. A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head. The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement. The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Performance Monitoring System: Summary of Lock Statistics. Revision 1.

    Science.gov (United States)

    1985-12-01

    2751 84 4057 4141 526 798 18 1342 5727 19 5523 3996 4587 8583 1056 1630 35 2721 6536LOCK A DAMI 2 AUXILIARY I Ins NO DATA RECORDD FOR THIS LOCK- " LOCK I...TOTAL (KTOMS) ’ - (AVt OPNP ETC) ’’ ,q [ " ARKANSAS RIVER "" FORRELL LOCK IP 7A/3TRC 9/N83 UPBOUID STATISTICS ISO 53 42 M6 553 356 909 221 41 21 M8

  2. Key-lock colloids in a nematic liquid crystal.

    Science.gov (United States)

    Silvestre, Nuno M; Tasinkevych, M

    2017-01-01

    The Landau-de Gennes free energy is used to study theoretically the effective interaction of spherical "key" and anisotropic "lock" colloidal particles. We assume identical anchoring properties of the surfaces of the key and of the lock particles, and we consider planar degenerate and perpendicular anchoring conditions separately. The lock particle is modeled as a spherical particle with a spherical dimple. When such a particle is introduced into a nematic liquid crystal, it orients its dimple at an oblique angle θ_{eq} with respect to the far field director n_{∞}. This angle depends on the depth of the dimple. Minimization results show that the free energy of a pair of key and lock particles exhibits a global minimum for the configuration when the key particle is facing the dimple of the lock colloidal particle. The preferred orientation ϕ_{eq} of the key-lock composite doublet relative to n_{∞} is robust against thermal fluctuations. The preferred orientation θ_{eq}^{(2)} of the dimple particle in the doublet is different from the isolated situation. This is related to the "direct" interaction of defects accompanying the key particle with the edge of the dimple. We propose that this nematic-amplified key-lock interaction can play an important role in self-organization and clustering of mixtures of colloidal particles with dimple colloids present.

  3. Damage assessment of composite plate structures with material and measurement uncertainty

    Science.gov (United States)

    Chandrashekhar, M.; Ganguli, Ranjan

    2016-06-01

    Composite materials are very useful in structural engineering particularly in weight sensitive applications. Two different test models of the same structure made from composite materials can display very different dynamic behavior due to large uncertainties associated with composite material properties. Also, composite structures can suffer from pre-existing imperfections like delaminations, voids or cracks during fabrication. In this paper, we show that modeling and material uncertainties in composite structures can cause considerable problem in damage assessment. A recently developed C0 shear deformable locking free refined composite plate element is employed in the numerical simulations to alleviate modeling uncertainty. A qualitative estimate of the impact of modeling uncertainty on the damage detection problem is made. A robust Fuzzy Logic System (FLS) with sliding window defuzzifier is used for delamination damage detection in composite plate type structures. The FLS is designed using variations in modal frequencies due to randomness in material properties. Probabilistic analysis is performed using Monte Carlo Simulation (MCS) on a composite plate finite element model. It is demonstrated that the FLS shows excellent robustness in delamination detection at very high levels of randomness in input data.

  4. Cervical cancer

    Science.gov (United States)

    ... bleeding between periods, after intercourse, or after menopause Vaginal discharge that does not stop, and may be pale, ... Instructions Hysterectomy - abdominal - discharge Hysterectomy - laparoscopic - ... Images Cervical cancer Cervical neoplasia ...

  5. Monolithic Hybrid and Passive Mode-Locked 40GHz Quantum Dot Laser Diodes

    DEFF Research Database (Denmark)

    Thompson, M. G.; Larsson, David; Rae, A. R.

    2006-01-01

    For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs.......For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs....

  6. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    Science.gov (United States)

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  7. Locks at reactor safety containments of nuclear power plants

    International Nuclear Information System (INIS)

    1978-12-01

    The rule is to be applied for material access locks. A material access lock as defined by this rule is a pressure resistant and technically gas-tight hollow body that is connected with the containment and has got two doors, the inner door of which connects the lock chamber with the interior of the containment and the outer door connects the lock chamber with the outside. It serves exclusively for transferring material or objects. (orig./HP) [de

  8. [Cervical cerclage].

    Science.gov (United States)

    Akladios, C Y; Sananes, N; Gaudineau, A; Boudier, E; Langer, B

    2015-10-01

    Cervical cerclage aims to strengthen not only the mechanical properties of the cervix, but also its immunological and anti-infectious functions. The demonstration of a strong interrelation between cervical insufficiency as well as decreased cervical length at endo-vaginal ultrasonography and infection has changed the indications cerclage. Actually we can distinguish three indications for cerclage: prophylactic, for obstetrical history; therapeutic, for shortened cervical length at ultrasonography in patients at risk and; emergency cerclage in case of threatening cervix at physical examination. The McDonald's technique is the most recommended. In case of failure, it is proposed to realize cerclage at a higher level on the cervix either by vaginal or abdominal route. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. 408-fs SESAM mode locked Cr:ZnSe laser

    Science.gov (United States)

    Bu, Xiangbao; Shi, Yuhang; Xu, Jia; Li, Huijuan; Wang, Pu

    2018-01-01

    We report self-starting femtosecond operation of a 127-MHz SESAM mode locked Cr:ZnSe laser around 2420 nm. A thulium doped double clad fiber laser at 1908 nm was used as the pumping source. In the normal dispersion regime, stable pulse pairs with constant phase differences in the multipulse regime were observed. The maximum output power was 342 mW with respect to incident pump power of 4.8 W and the corresponding slope efficiency was 10.4%. By inserting a piece of sapphire plate, dispersion compensation was achieved and the intra-cavity dispersion was moved to the anomalous regime. A maximum output power of 403 mW was obtained and the corresponding slope efficiency was 12.2%. Pulse width was measured to be 408 fs by a collinear autocorrelator using two-photon absorption in an InGaAs photodiode. The laser spectrum in multipulse operation showed a clear periodic modulation.

  10. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    Science.gov (United States)

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  11. ''Old'' locked inflation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang; Piao, Yun-Song [College of Physical Sciences, Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Si, Zong-Guo, E-mail: liuyangbyf@mail.sdu.edu.cn, E-mail: yspiao@gucas.ac.cn, E-mail: zgsi@sdu.edu.cn [Department of Physics, Shandong University, Jinan 250100 (China)

    2009-05-15

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' {phi}. Instead of rolling down along the potential, the {phi} field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape.

  12. Improving generalized inverted index lock wait times

    Science.gov (United States)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  13. New constraints on slip rates and locking depths of the San Andreas Fault System from Sentinel-1A InSAR and GAGE GPS observations

    Science.gov (United States)

    Ward, L. A.; Smith-Konter, B. R.; Higa, J. T.; Xu, X.; Tong, X.; Sandwell, D. T.

    2017-12-01

    After over a decade of operation, the EarthScope (GAGE) Facility has now accumulated a wealth of GPS and InSAR data, that when successfully integrated, make it possible to image the entire San Andreas Fault System (SAFS) with unprecedented spatial coverage and resolution. Resulting surface velocity and deformation time series products provide critical boundary conditions needed for improving our understanding of how faults are loaded across a broad range of temporal and spatial scales. Moreover, our understanding of how earthquake cycle deformation is influenced by fault zone strength and crust/mantle rheology is still developing. To further study these processes, we construct a new 4D earthquake cycle model of the SAFS representing the time-dependent 3D velocity field associated with interseismic strain accumulation, co-seismic slip, and postseismic viscoelastic relaxation. This high-resolution California statewide model, spanning the Cerro Prieto fault to the south to the Maacama fault to the north, is constructed on a 500 m spaced grid and comprises variable slip and locking depths along 42 major fault segments. Secular deep slip is prescribed from the base of the locked zone to the base of the elastic plate while episodic shallow slip is prescribed from the historical earthquake record and geologic recurrence intervals. Locking depths and slip rates for all 42 fault segments are constrained by the newest GAGE Facility geodetic observations; 3169 horizontal GPS velocity measurements, combined with over 53,000 line-of-sight (LOS) InSAR velocity observations from Sentinel-1A, are used in a weighted least-squares inversion. To assess slip rate and locking depth sensitivity of a heterogeneous rheology model, we also implement variations in crustal rigidity throughout the plate boundary, assuming a coarse representation of shear modulus variability ranging from 20-40 GPa throughout the (low rigidity) Salton Trough and Basin and Range and the (high rigidity) Central

  14. John locke on personal identity.

    Science.gov (United States)

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  15. John Locke on Personal Identity**

    OpenAIRE

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  16. Injection locking of optomechanical oscillators via acoustic waves

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-01

    Injection locking is a powerful technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators using similar or other types of oscillators. Here, we present the first demonstration of injection locking of a radiation-pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can easily be implemented on various platforms. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  17. Taurolidine lock is superior to heparin lock in the prevention of catheter related bloodstream infections and occlusions.

    Directory of Open Access Journals (Sweden)

    Evelyn D Olthof

    Full Text Available Patients on home parenteral nutrition (HPN are at risk for catheter-related complications; mainly infections and occlusions. We have previously shown in HPN patients presenting with catheter sepsis that catheter locking with taurolidine dramatically reduced re-infections when compared with heparin. Our HPN population therefore switched from heparin to taurolidine in 2008. The aim of the present study was to compare long-term effects of this catheter lock strategy on the occurrence of catheter-related bloodstream infections and occlusions in HPN patients.Data of catheter-related complications were retrospectively collected from 212 patients who received HPN between January 2000 and November 2011, comprising 545 and 200 catheters during catheter lock therapy with heparin and taurolidine, respectively. We evaluated catheter-related bloodstream infection and occlusion incidence rates using Poisson-normal regression analysis. Incidence rate ratios were calculated by dividing incidence rates of heparin by those of taurolidine, adjusting for underlying disease, use of anticoagulants or immune suppressives, frequency of HPN/fluid administration, composition of infusion fluids, and duration of HPN/fluid use before catheter creation.Bloodstream infection incidence rates were 1.1/year for heparin and 0.2/year for taurolidine locked catheters. Occlusion incidence rates were 0.2/year for heparin and 0.1/year for taurolidine locked catheters. Adjusted incidence ratios of heparin compared to taurolidine were 5.9 (95% confidence interval, 3.9-8.7 for bloodstream infections and 1.9 (95% confidence interval, 1.1-3.1 for occlusions.Given that no other procedural changes than the catheter lock strategy were implemented during the observation period, these data strongly suggest that taurolidine decreases catheter-related bloodstream infections and occlusions in HPN patients compared with heparin.

  18. Coupled optical resonance laser locking.

    Science.gov (United States)

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  19. Genomic and Functional Characterization of the Unusual pLOCK 0919 Plasmid Harboring the spaCBA Pili Cluster in Lactobacillus casei LOCK 0919

    Science.gov (United States)

    Aleksandrzak-Piekarczyk, Tamara; Koryszewska-Bagińska, Anna; Grynberg, Marcin; Nowak, Adriana; Cukrowska, Bożena; Kozakova, Hana; Bardowski, Jacek

    2016-01-01

    Here, we report the extensive bioinformatic and functional analyses of the unusual pLOCK 0919, a plasmid originating from the probiotic Lactobacillus casei LOCK 0919 strain. This plasmid is atypical because it harbors the spaCBA-srtC gene cluster encoding SpaCBA pili. We show that all other spaCBA-srtC sequences of the Lactobacillus genus that have been previously described and deposited in GenBank are present in the chromosomal DNA. Another important observation for pLOCK 0919 is that the spaCBA-srtC gene cluster and its surrounding genes are highly similar to the respective DNA region that is present in the most well-known and active SpaCBA pili producer, the probiotic Lactobacillus rhamnosus GG strain. Our results demonstrate that the spaCBA-srtC clusters of pLOCK 0919 and L. rhamnosus GG are genealogically similar, located in DNA regions that are rich in transposase genes and are poorly conserved among the publicly available sequences of Lactobacillus sp. In contrast to chromosomally localized pilus gene clusters from L. casei and Lactobacillus paracasei, the plasmidic spaC of L. casei LOCK 0919 is expressed and undergoes a slight glucose-induced repression. Moreover, results of series of in vitro tests demonstrate that L. casei LOCK 0919 has an adhesion potential, which is largely determined by the presence of the pLOCK 0919 plasmid. In particular, the plasmid occurrence positively influenced the hydrophobicity and aggregation abilities of L. casei LOCK 0919. Moreover, in vivo studies indicate that among the three Lactobacillus strains used to colonize the gastrointestinal tract of germ-free mice, already after 2 days of colonization, L. casei LOCK 0919 became the dominant strain and persisted there for at least 48 days. PMID:26637469

  20. Headache of cervical origin

    Energy Technology Data Exchange (ETDEWEB)

    Burguet, J L; Wackenheim, A

    1984-08-01

    The authors recall cervical etiologies of headache. They distinguish on the one hand the cervico-occipital region with minor and major malformations and acquired lesions, and on the other hand the middle and inferior cervical segment. They also recall the original structuralist analysis of the cervical spine and give the example of the ''cervical triplet''.

  1. Quality of life in symptomatic cervical myelopathy after open-door laminoplasty

    Directory of Open Access Journals (Sweden)

    Rodrigo Yuiti Nakao

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the results obtained by open-door laminoplasty using the Newbridge(r/Blackstone plate, in cases of myelopathy associated with cervical lordosis.METHODS: From December 2010 to October 2012, eight patients between the ages of 49 and 68 underwent open-door laminoplasty with the use of the Newbridge(r fixation system for maintenance and stabilization of the cervical laminoplasty. Minimum follow-up was four months. For the evaluation of quality of life the questionnaire SF-36 was applied at the following times: preoperative, one month and three months after surgery associated with the subjective assessment of the patient regarding satisfaction with the procedure and with the Nurick neurological scale applied prior to surgery and three months later.RESULTS: According to the SF-36, there was significant improvement in the domains functional ability, general health perceptions and emotional aspects over time; regarding physical limitations and social aspects there was no improvement in the first postoperative month, only in the third month. There were no statistically significant changes observed during the period covered by this study related to pain, vitality and mental health. According to Nurick scale, there was evidence of improvement in symptoms of cervical myelopathy. Based on the subjective evaluation of the patients, surprisingly, all patients were satisfied with the surgical procedure and the results.CONCLUSION: The open-door laminoplasty technique with rigid fixation to maintain the opening is useful in improving the symptoms of cervical myelopathy associated with lordosis, leading to improved quality of life and with a high degree of patient satisfaction and fewer complications.

  2. The rheumatoid cervical spine: Signs of instability on plain cervical radiographs

    International Nuclear Information System (INIS)

    Roche, Clare J.; Eyes, Brian E.; Whitehouse, Graham H.

    2002-01-01

    The cervical spine is a common focus of destruction from rheumatoid arthritis, second only to the metacarpophalangeal joints. Joint, bone and ligament damage in the cervical spine leads to subluxations which can cause cervical cord compression resulting in paralysis and even sudden death. Because many patients with significant subluxations are asymptomatic, the radiologist plays a key role in recognizing the clinically important clues to instability on plain radiographs of the cervical spine-often difficult in rheumatoid arthritis when the bony landmarks are osteoporotic or eroded. This review focuses on the signs of instability on plain radiographs of the cervical spine, using diagrams and clinical examples to illustrate methods of identifying significant subluxations in rheumatoid arthritis. Roche, C.J., Eyes, B.E. and Whitehouse, G.H. (2002)

  3. CORRELATION BETWEEN CERVICAL SAGITTAL ALIGNMENT AND FUNCTIONAL CAPACITY IN CERVICAL SPONDYLOSIS

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    Full Text Available ABSTRACT Objective: To correlate the radiographic parameters of sagittal cervical alignment with quality of life and functional capacity in patients with cervical spondylosis under conservative treatment. Methods: This is an observational and prospective study in patients with cervical spondylosis under conservative treatment and without indication for surgery. The 52 patients included were divided into three groups: axial pain, radiculopathy, and cervical myelopathy. The radiographic parameters considered were cervical lordosis (CL, cervical sagittal vertical axis (CSVA, T1 slope (TS and the discrepancy between TS and CL (TS-CL. Quality of life and functional capacity were evaluated by the Neck Disability Index (NDI questionnaire. Pain was assessed by the Visual Analogue Scale (VAS. The correlation between the radiographic parameters and the clinical scores was evaluated by the Pearson correlations coefficient. Results: There was no difference in cervical radiographic parameters between the three groups. In the total of the sample, the mean value of the CSVA was 17.8o (±8.3o, CL, 22.4° (± 8.8°; TS, 29.3° (±6.6°, and TS-CL, 7.0° (±7.4°. Significant inverse correlation (r= -0.3, p=0.039 was observed between NDI and CL, but there was no significant correlation between CL and VAS. CSVA (p=0.541, TS (p=0.287 and TS-CL (p=0.287 had no significantly correlated with NDI or VAS. Conclusion: Considering patients with cervical spondylosis not candidates for surgery, the only sagittal parameter that correlated with functional capacity was LC. In these patients, the correlation between cervical alignment and quality of life needs to be better characterized.

  4. Analysis of peer-to-peer locking of magnetrons

    International Nuclear Information System (INIS)

    Pengvanich, P.; Lau, Y. Y.; Cruz, E.; Gilgenbach, R. M.; Hoff, B.; Luginsland, J. W.

    2008-01-01

    The condition for mutual, or peer-to-peer, locking of two magnetrons is derived. This condition reduces to Adler's classical phase-locking condition in the limit where one magnetron becomes the ''master'' and the other becomes the ''slave.'' The formulation is extended to the peer-to-peer locking of N magnetrons, under the assumption that the electromagnetic coupling among the N magnetrons is modeled by an N-port network.

  5. Headache of cervical origin

    International Nuclear Information System (INIS)

    Burguet, J.L.; Wackenheim, A.

    1984-01-01

    The authors recall cervical etiologies of headache. They distinguish on the one hand the cervico-occipital region with minor and major malformations and acquired lesions, and on the other hand the middle and inferior cervical segment. They also recall the original structuralist analysis of the cervical spine and give the example of the ''cervical triplet''. (orig.) [de

  6. Outer Rail for Wall Plate Covering

    DEFF Research Database (Denmark)

    2013-01-01

    including an abutment part, which extends inwards from the inner side of the retention web such as to form an abutment surface for the respective screw web when the latter is positioned to be retained in the retention device, and extends from the abutment part into a locking part, which extends at an angle...... to the abutment part and at a distance from the respective retention web. Each locking part comprising a first resilient locking pin adapted to lock a first screw web configuration and a second, separate resilient locking pin adapted to lock a second screw web configuration, the first and second screw web...

  7. Comparison between anterior cervical discectomy with fusion by polyetheretherketone cages and tricortical iliac-crest graft for the treatment of cervical prolapsed intervertebral disc

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2016-10-01

    Full Text Available Anterior cervical discectomy and fusion is effective surgical modality in the treatment of cervical prolapsed intervertebral disc, radiculopathy and myelopathy. Aims of our study is to evaluate fusion of cervical spine  by ICG with plating and PEEK cage with bone graft, also assess the donor site morbidity. Thirty patients (male 16; female 14 with mean age 46 ± 9.2 years and were distributed  into two treatment groups (PEEK cage group and ICG group. We assess the patients clinically for myelopathy and functional outcome by Nurick scale and Odom's criteria respectively and  neck and arm pain by Visual Analogue Scale (VAS. Eighteen patients were operated for single level discectomy and fusion by either ICG or PEEK cages and twelve patients for two levels. After surgery follow up was 2 years and better  postoperative score which was assessed by Nurick scale, Odoms criteria and VAS score. Total patients 14(93%were graded excellent in the PEEK cage group compared to 13 patients (86% in the ICG group.  Statistically it was not significant between two groups and p value was <0.35. Difference was significant in VAS score  after 24 months with more reduction of pain in PEEK cage group. Fusion occurred in 13 patients (86% of the PEEK cage group and 14 patient (93% of the ICG group. Result showed more fusion rate in ICG group and less donor site morbidity in PEEK group.  

  8. Cervical Cancer

    Science.gov (United States)

    ... the place where a baby grows during pregnancy. Cervical cancer is caused by a virus called HPV. The ... for a long time, or have HIV infection. Cervical cancer may not cause any symptoms at first. Later, ...

  9. ELB-trees - Efficient Lock-free B+trees

    DEFF Research Database (Denmark)

    Bonnichsen, Lars Frydendal; Karlsson, Sven; Probst, Christian W.

    2014-01-01

    As computer systems scale in the number of processors, data structures with good parallel performance become increasingly important. Lock-free data structures promise improved parallel performance at the expense of higher complexity and sequential execution time.We present ELBtrees, a new lock-fr...

  10. Primary culture of glial cells from mouse sympathetic cervical ganglion: a valuable tool for studying glial cell biology.

    Science.gov (United States)

    de Almeida-Leite, Camila Megale; Arantes, Rosa Maria Esteves

    2010-12-15

    Central nervous system glial cells as astrocytes and microglia have been investigated in vitro and many intracellular pathways have been clarified upon various stimuli. Peripheral glial cells, however, are not as deeply investigated in vitro despite its importance role in inflammatory and neurodegenerative diseases. Based on our previous experience of culturing neuronal cells, our objective was to standardize and morphologically characterize a primary culture of mouse superior cervical ganglion glial cells in order to obtain a useful tool to study peripheral glial cell biology. Superior cervical ganglia from neonatal C57BL6 mice were enzymatically and mechanically dissociated and cells were plated on diluted Matrigel coated wells in a final concentration of 10,000cells/well. Five to 8 days post plating, glial cell cultures were fixed for morphological and immunocytochemical characterization. Glial cells showed a flat and irregular shape, two or three long cytoplasm processes, and round, oval or long shaped nuclei, with regular outline. Cell proliferation and mitosis were detected both qualitative and quantitatively. Glial cells were able to maintain their phenotype in our culture model including immunoreactivity against glial cell marker GFAP. This is the first description of immunocytochemical characterization of mouse sympathetic cervical ganglion glial cells in primary culture. This work discusses the uses and limitations of our model as a tool to study many aspects of peripheral glial cell biology. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Hew Locke: House of Cards

    OpenAIRE

    Reckitt, Helena; Joyce, Julie; Locke, Hew

    2004-01-01

    ‘Hew Locke: House of Cards’ featured a selection of the artist's portraits of British royalty in various media, and his response to other trappings of the monarchy and empire. The show included works previously exhibited at the Luckman Gallery, Los Angeles, in tandem with a newly commissioned coat of arms, and other recent works. \\ud \\ud Locke draws from everyday sources, ranging from items found in London's Brixton Market to discount fabric shops and thrift stores. Other sources of inspirati...

  12. Modeling of mode-locked coupled-resonator optical waveguide lasers

    DEFF Research Database (Denmark)

    Agger, Christian; Skovgård, Troels Suhr; Gregersen, Niels

    2010-01-01

    Coupled-resonator optical waveguides made from coupled high-Q photonic crystal nanocavities are investigated for use as cavities in mode-locked lasers. Such devices show great potential in slowing down light and can serve to reduce the cavity length of a mode-locked laser. An explicit expression...... of the emerging pulse train. A range of tuning around this frequency allows for effective mode locking. Finally, noise is added to the generalized single-cavity eigenfrequencies in order to evaluate the effects of fabrication imperfections on the cold-cavity transmission properties and consequently on the locking...

  13. Delay differential equations for mode-locked semiconductor lasers.

    Science.gov (United States)

    Vladimirov, Andrei G; Turaev, Dmitry; Kozyreff, Gregory

    2004-06-01

    We propose a new model for passive mode locking that is a set of ordinary delay differential equations. We assume a ring-cavity geometry and Lorentzian spectral filtering of the pulses but do not use small gain and loss and weak saturation approximations. By means of a continuation method, we study mode-locking solutions and their stability. We find that stable mode locking can exist even when the nonlasing state between pulses becomes unstable.

  14. 30 CFR 57.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  15. A CLINICAL STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE (LCP - PF IN THE MANAGEMENT OF COMMUNITED INTERTROCHANTERIC AND SUBTROCHANTERIC FRACTURES OF THE FEMUR

    Directory of Open Access Journals (Sweden)

    Hari Babu

    2015-10-01

    Full Text Available Fractures of proximal femur and hip are relatively common injuries in elderly individuals . The incidence of peritrochanteric and intertrochanteric fracture is also increasing among young population, who sustain high energy trauma Rigid Internal fixation and early mobilization has been the standard method of treatment. A combination of orthopaedic surgery and early postoperative physiotherapy and ambulation is the best approach. The overall goal in the treatment of hip fractures is to return the patient to pre - morbid level of function. AIMS & OBJECTIVE : To analyse the anatomical and f unctional outcome of the treatment with LCP - Proximal femur. METHODOLOGY : The present study consists of 12 adult patients of peritrochanteric factures of femur satisfying the inclusion criteria , treated with Proximal Femoral Locking Compression Plate at S. V. R. R . Govt . General Hospital, Tirupati during the period of nov 2013 to Oct 2015. INCLUSION CRITERIA : Age >18years , comminuted trochanteric and sub trochanteric fractures , Signed written informed consent . EXCLUSION CRITERIA: Inter trochanteric fractures involving piriformis fossa , Compound fractures . Pathological fractures . Any displacement of a femoral neck fracture . A ssociated malignancy. RESULTS : Average age incidence in the present study was 62.7 years. , Predominantly males (75% were affected. , Most cases occurred after a fall 10 (50% cases which was statistically significant , Right side involvement was more common. , Average post - operative stay was 13.5 days. , Out of the 12 cases, evaluated using Salvati - Wilson scoring : 3 cases (25% had good, 8 cases (66.67% fair, 1 case (8.33% had poor score , Average weight bearing time was14.5 weeks , Average union rate was 19.45 weeks.

  16. Correlations between locked modes and impurity influxes

    Energy Technology Data Exchange (ETDEWEB)

    Fishpool, G M [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Lawson, K D [UKAEA Culham Lab., Abingdon (United Kingdom)

    1994-07-01

    An analysis of pulses that were disturbed by medium Z impurity influxes (Cl, Cr, Fe and Ni) recorded during the 91/92 JET operations, has demonstrated that such influxes can result in MHD modes which subsequently ``lock``. A correlation is found between the power radiated by the influx and the time difference between the start of the influx and the beginning of the locked mode. The growth in the amplitude of the locked mode itself can lead to further impurity influxes. A correlation is noted between intense influxes (superior to 10 MW) and the mode ``unlocking``. (authors). 4 refs., 4 figs.

  17. Squeezing in an injection-locked semiconductor laser

    Science.gov (United States)

    Inoue, S.; Machida, S.; Yamamoto, Y.; Ohzu, H.

    1993-09-01

    The intensity-noise properties of an injection-locked semiconductor laser were studied experimentally. The constant-current-driven semiconductor laser producing the amplitude-squeezed state whose intensity noise was reduced below the standard quantum limit (SQL) by 0.72 dB was injection-locked by an external master laser. The measured intensity-noise level of the injection-locked semiconductor laser was 0.91 dB below the SQL. This experimental result indicates that a phase-coherent amplitude-squeezed state or squeezed vacuum state together with a reference local oscillator wave can be generated directly by semiconductor laser systems.

  18. Mutual phase-locking of planar nano-oscillators

    Directory of Open Access Journals (Sweden)

    K. Y. Xu

    2014-06-01

    Full Text Available Characteristics of phase-locking between Gunn effect-based planar nano-oscillators are studied using an ensemble Monte Carlo (EMC method. Directly connecting two oscillators in close proximity, e.g. with a channel distance of 200 nm, only results in incoherent oscillations. In order to achieve in-phase oscillations, additional considerations must be taken into account. Two coupling paths are shown to exist between oscillators. One coupling path results in synchronization and the other results in anti-phase locking. The coupling strength through these two paths can be adjusted by changing the connections between oscillators. When two identical oscillators are in the anti-phase locking regime, fundamental components of oscillations are cancelled. The resulting output consists of purely second harmonic oscillations with a frequency of about 0.66 THz. This type of second harmonic generation is desired for higher frequency applications since no additional filter system is required. This transient phase-locking process is further analyzed using Adler's theory. The locking range is extracted, and a criterion for the channel length difference required for realizing phased arrays is obtained. This work should aid in designing nano-oscillator arrays for high power applications and developing directional transmitters for wireless communications.

  19. Experimental implementation of phase locking in a nonlinear interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn [State Key Laboratory of Precision Spectroscopy, Department of Physics, East China Normal University, Shanghai 200062 (China); Marino, A. M. [Homer L. Dodge Department of Physics and Astronomy, The University of Oklahoma, 440 West Brooks Street, Norman, Oklahoma 73019 (United States)

    2015-09-21

    Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in such a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.

  20. Locked doors in acute inpatient psychiatry: a literature review.

    Science.gov (United States)

    van der Merwe, M; Bowers, L; Jones, J; Simpson, A; Haglund, K

    2009-04-01

    Many acute inpatient psychiatric wards in the UK are permanently locked, although this is contrary to the current Mental Health Act Code of Practice. To conduct a literature review of empirical articles concerning locked doors in acute psychiatric inpatient wards, an extensive literature search was performed in SAGE Journals Online, EBM Reviews, British Nursing Index, CINAHL, EMBASE Psychiatry, International Bibliography of the Social Sciences, Ovid MEDLINE, PsycINFO and Google, using the search terms 'open$', 'close$', '$lock$', 'door', 'ward', 'hospital', 'psychiatr', 'mental health', 'inpatient' and 'asylum'. A total of 11 empirical papers were included in the review. Both staff and patients reported advantages (e.g. preventing illegal substances from entering the ward and preventing patients from absconding and harming themselves or others) and disadvantages (e.g. making patients feel depressed, confined and creating extra work for staff) regarding locked doors. Locked wards were associated with increased patient aggression, poorer satisfaction with treatment and more severe symptoms. The limited literature available showed the urgent need for research to determine the real effects of locked doors in inpatient psychiatry.

  1. QPSK regeneration without active phase-locking

    DEFF Research Database (Denmark)

    Kjøller, Niels-Kristian; Da Ros, Francesco; Røge, Kasper Meldgaard

    2016-01-01

    QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal.......QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal....

  2. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  3. A Digital Phase Lock Loop for an External Cavity Diode Laser

    Science.gov (United States)

    Wang, Xiao-Long; Tao, Tian-Jiong; Cheng, Bing; Wu, Bin; Xu, Yun-Fei; Wang, Zhao-Ying; Lin, Qiang

    2011-08-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems.

  4. Cervical cancer - screening and prevention

    Science.gov (United States)

    Cancer cervix - screening; HPV - cervical cancer screening; Dysplasia - cervical cancer screening; Cervical cancer - HPV vaccine ... Almost all cervical cancers are caused by HPV (human papilloma virus). HPV is a common virus that spreads through sexual contact. Certain ...

  5. Long term results of anterior corpectomy and fusion for cervical spondylotic myelopathy.

    Directory of Open Access Journals (Sweden)

    Rui Gao

    Full Text Available BACKGROUND: Results showed good clinical outcomes of anterior corpectomy and fusion (ACCF for patients with cervical spondylotic myelopathy (CSM during a short term follow-up; however, studies assessing long term results are relatively scarce. In this study we intended to assess the long term clinical and radiographic outcomes, find out the factors that may affect the long term clinical outcome and evaluate the incidence of adjacent segment disease (ASD. METHODS: This is a retrospective study of 145 consecutive CSM patients on ACCF treatment with a minimum follow-up of 5 years. Clinical data were collected from medical and operative records. Patients were evaluated by using the Japanese Orthopedic Association (JOA scoring system preoperatively and during the follow-up. X-rays results of cervical spine were obtained from all patients. Correlations between the long term clinical outcome and various factors were also analyzed. FINDINGS: Ninety-three males and fifty-two females completed the follow-up. The mean age at operation was 51.0 years, and the mean follow-up period was 102.1 months. Both postoperative sagittal segmental alignment (SSA and the sagittal alignment of the whole cervical spine (SACS increased significantly in terms of cervical lordosis. The mean increase of JOA was 3.8 ± 1.3 postoperatively, and the overall recovery rate was 62.5%. Logistic regression analysis showed that preoperative duration of symptoms >12 months, high-intensity signal in spinal cord and preoperative JOA score ≤ 9 were important predictors of the fair recovery rate (≤ 50%. Repeated surgery due to ASD was performed in 7 (4.8% cases. CONCLUSIONS: ACCF with anterior plate fixation is a reliable and effective method for treating CSM in terms of JOA score and the recovery rate. The correction of cervical alignment and the repeated surgery rate for ASD are also considered to be satisfactory.

  6. Phase-locked loops. [in analog and digital circuits communication system

    Science.gov (United States)

    Gupta, S. C.

    1975-01-01

    An attempt to systematically outline the work done in the area of phase-locked loops which are now used in modern communication system design is presented. The analog phase-locked loops are well documented in several books but discrete, analog-digital, and digital phase-locked loop work is scattered. Apart from discussing the various analysis, design, and application aspects of phase-locked loops, a number of references are given in the bibliography.

  7. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  8. TTV and HPV co-infection in cervical smears of patients with cervical lesions

    Directory of Open Access Journals (Sweden)

    Tachezy Ruth

    2009-07-01

    Full Text Available Abstract Background The female lower genital tract is a gateway for pathogens entering the host through the mucous membrane. One of the prevalent human viruses is Torque teno virus (TTV. The major reported routes of TTV transmission are fecal-oral and parenteral. Furthermore, other modes of transmission, e.g. sexual contact, are suggested. To investigate the sexual route of TTV transmission, cervical smears of healthy women and those with cervical lesions were screened for the presence of TTV DNA. Methods TTV DNA was studied in cervical smears of 95 patients with cervical lesions and 55 healthy women. Paired serum samples were available from 55 and 42 women, respectively. All healthy women had normal cytology while 44 patients had histologically confirmed low-grade lesion (LGL and 51 high-grade lesion (HGL. TTV DNA was detected with primers specific for the non-coding region. In 40 paired cervical smears and serum samples, the phylogenetic group of TTV isolates was determined. The presence of HPV DNA in cervical smears was detected by means of PCR with MY09/11 primers. Results The prevalence of TTV DNA in cervical smears of healthy women was 52.7% and was comparable with that in paired serum samples (50%. Symptomatic women had significantly higher prevalence of TTV DNA in cervical smears (74.7% than healthy controls. The TTV DNA prevalence in patient serum samples was 51%. The phylogenetic groups of TTV serum isolates were concordant with those of TTV from cervical smears of the same subjects. In cervical smears, a wider variety of TTV isolates was found. The viral loads in cervical smears were 10 to 1000 times as high as in sera. The HPV-positive study subjects had significantly higher TTV DNA prevalence than HPV negatives. The prevalence of TTV was not associated with disease severity. Conclusion High prevalence of TTV in cervical smears suggests that sexual transmission is another mode of expansion of TTV infection among the population. The

  9. SCREENING FOR CERVICAL CANCER

    African Journals Online (AJOL)

    Enrique

    Cervical cancer remains a major health concern worldwide, especially in devel- ... Important aspects of cervical cancer screening include the age at which .... High-risk types HPV (16,18) are impli- cated in the pathogenesis of cervical cancer.

  10. Polarization switching detection method using a ferroelectric liquid crystal for dichroic atomic vapor laser lock frequency stabilization techniques.

    Science.gov (United States)

    Dudzik, Grzegorz; Rzepka, Janusz; Abramski, Krzysztof M

    2015-04-01

    We present a concept of the polarization switching detection method implemented for frequency-stabilized lasers, called the polarization switching dichroic atomic vapor laser lock (PSDAVLL) technique. It is a combination of the well-known dichroic atomic vapor laser lock method for laser frequency stabilization with a synchronous detection system based on the surface-stabilized ferroelectric liquid crystal (SSFLC).The SSFLC is a polarization switch and quarter wave-plate component. This technique provides a 9.6 dB better dynamic range ratio (DNR) than the well-known two-photodiode detection configuration known as the balanced polarimeter. This paper describes the proposed method used practically in the VCSEL laser frequency stabilization system. The applied PSDAVLL method has allowed us to obtain a frequency stability of 2.7×10⁻⁹ and a reproducibility of 1.2×10⁻⁸, with a DNR of detected signals of around 81 dB. It has been shown that PSDAVLL might be successfully used as a method for spectra-stable laser sources.

  11. Plate fixation for proximal chevron osteotomy has greater risk for hallux valgus recurrence than Kirschner wire fixation.

    Science.gov (United States)

    Park, Chul-Hyun; Ahn, Ji-Yong; Kim, Yu-Mi; Lee, Woo-Chun

    2013-06-01

    The purpose of this study was to compare the results of hallux valgus surgery between feet fixed with Kirschner wires and those fixed with a plate and screws. Between December 2008 and November 2009, 53 patients (62 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. Thirty-four patients (41 feet) were stabilised with Kirschner wires (K-wire group) and 19 patients (21 feet) were stabilised with a locking plate (plate group). Clinical results were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score. Radiographic parameters were compared between these groups. Recurrence rate at the last follow-up was compared between the K-wire and plate groups. Mean AOFAS score was lower in the plate group, however, the difference between the groups was not statistically significant in AOFAS score at the last follow-up. Hallux valgus angle and intermetatarsal angle were significantly larger in the plate group at the last follow-up. Mean 1-2 metatarsal (MT) distance on immediately postoperative radiographs was significant larger in the plate group. Four (9.8 %) of the 41 feet in the K-wire group and 7 (33.3 %) of the 21 feet in the plate group showed hallux valgus recurrence at the last follow-up. The plate group had a significantly higher risk of recurrence than the K-wire group. Fixation of proximal chevron osteotomy using a plate and screws has a greater risk of hallux valgus recurrence than fixation using Kirschner wires.

  12. Investigation of CPD and HMDS Sample Preparation Techniques for Cervical Cells in Developing Computer-Aided Screening System Based on FE-SEM/EDX

    Science.gov (United States)

    Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system. PMID:25610902

  13. Pathophysiology of cervical myelopathy.

    Science.gov (United States)

    Baptiste, Darryl C; Fehlings, Michael G

    2006-01-01

    Cervical myelopathy is a group of closely related disorders usually caused by spondylosis or by ossification of the posterior longitudinal ligament and is characterized by compression of the cervical spinal cord or nerve roots by varying degrees and number of levels. The decrease in diameter of the vertebral canal secondary to disc degeneration and osteophytic spurs compresses the spinal cord and nerve roots at one or several levels, producing direct damage and often secondary ischemic changes. Clinicians who treat cervical myelopathy cord injuries should have a basic understanding of the pathophysiology and the processes that are initiated after the spinal cord has been injured. Literature review. Literature review of human cervical myelopathy and clinically relevant animal models to further our understanding of the pathological mechanisms involved. The pathophysiology of cervical myelopathy involves static factors, which result in acquired or developmental stenosis of the cervical canal and dynamic factors, which involve repetitive injury to the cervical cord. These mechanical factors in turn result in direct injury to neurons and glia as well as a secondary cascade of events including ischemia, excitotoxicity, and apoptosis; a pathobiology similar to that occurring in traumatic spinal cord injury. This review summarizes some of the significant pathophysiological processes involved in cervical myelopathy.

  14. High-Order Frequency-Locked Loops

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In very recent years, some attempts for designing high-order frequency-locked loops (FLLs) have been made. Nevertheless, the advantages and disadvantages of these structures, particularly in comparison with a standard FLL and high-order phase-locked loops (PLLs), are rather unclear. This lack...... study, and its small-signal modeling, stability analysis, and parameter tuning are presented. Finally, to gain insight about advantages and disadvantages of high-order FLLs, a theoretical and experimental performance comparison between the designed second-order FLL and a standard FLL (first-order FLL...

  15. Mode-locked silicon evanescent lasers.

    Science.gov (United States)

    Koch, Brian R; Fang, Alexander W; Cohen, Oded; Bowers, John E

    2007-09-03

    We demonstrate electrically pumped lasers on silicon that produce pulses at repetition rates up to 40 GHz. The mode locked lasers generate 4 ps pulses with low jitter and extinction ratios above 18 dB, making them suitable for data and telecommunication transmitters and for clock generation and distribution. Results of both passive and hybrid mode locking are discussed. This type of device could enable new silicon based integrated technologies, such as optical time division multiplexing (OTDM), wavelength division multiplexing (WDM), and optical code division multiple access (OCDMA).

  16. Experimental study on working characteristics of density lock

    International Nuclear Information System (INIS)

    Sun Furong; Yan Changqi; Gu Haifeng

    2011-01-01

    The working principle of density lock was introduced in this paper, and the experimental loop was built so that researches on working performance of density lock in the system were done at steady-state operation and pump trip conditions. The results show that at steady-state operation conditions, density lock can keep close in a long run, which will separate passive residual heat removal circuit from primary circuit. As a result, passive residual heat removal circuit is in the non-operating conditions, which dose not influence normal operation of reactors. At the pump trip conditions, density lock can be automatically opened quickly, which will make primary and passive residual heat removal system communicated. The natural circulation is well established in the two systems, and is enough to ensure removal of residual heat. (authors)

  17. Development of thermal actuators with multi-locking positions

    Science.gov (United States)

    Luo, J. K.; Zhu, Y.; Fu, Y. Q.; Flewitt, A. J.; Spearing, S. M.; Miao, J. M.; Milne, W. I.

    2006-04-01

    To reduce power consumption and operation temperature for micro-thermal actuators, metal-based micro-mechanical locks with multi-locking positions were analyzed and fabricated. The micro-locks consist of two or three U-shaped thermal actuators. The devices were made by a single mask process using electroplated Ni as the active material. Tests showed that the metal based thermal actuators deliver a maximum displacement of ~20µm at a much lower temperature than that of Si-based actuators. However Ni-actuators showed a severe back bending, which increases with increasing applied power. The temperature to initiate the back bending is as low as ~240°C. Back bending increases the distance between the two actuators, and leads to locking function failure. For practical application, Ni-based thermal actuators must be operated below 200°C.

  18. Active stabilization of a diode laser injection lock.

    Science.gov (United States)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-06-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  19. Cervical bracing practices after degenerative cervical surgery: a survey of cervical spine research society members.

    Science.gov (United States)

    Lunardini, David J; Krag, Martin H; Mauser, Nathan S; Lee, Joon Y; Donaldson, William H; Kang, James D

    2018-05-21

    Context: Prior studies have shown common use of post-operative bracing, despite advances in modern day instrumentation rigidity and little evidence of brace effectiveness. To document current practice patterns of brace use after degenerative cervical spine surgeries among members of the Cervical Spine Research Society (CSRS), to evaluate trends, and to identify areas of further study. A questionnaire survey METHODS: A 10 question survey was sent to members of the Cervical Spine Research Society to document current routine bracing practices after various common degenerative cervical spine surgical scenarios, including fusion and non-fusion procedures. The overall bracing rate was 67%. This included 8.4% who used a hard collar in each scenario. Twenty-two percent of surgeons never used a hard collar, while 34% never used a soft collar, and 3.6% (3 respondents) did not use a brace in any surgical scenario. Bracing frequency for specific surgical scenarios varied from 39% after foraminotomy to 88% after multi-level corpectomy with anterior & posterior fixation. After one, two and three level anterior cervical discectomy & fusion (ACDF), bracing rates were 58%, 65% and 76% for an average of 3.3, 4.3 and 5.3 weeks, respectively. After single level corpectomy, 77% braced for an average of 6.2 weeks. After laminectomy and fusion, 72% braced for an average of 5.4 weeks. Significant variation persists among surgeons on the type and length of post-operative brace usage after cervical spine surgeries. Overall rates of bracing have not changed significantly with time. Given the lack evidence in the literature to support bracing, reconsidering use of a brace after certain surgeries may be warranted. Copyright © 2018. Published by Elsevier Inc.

  20. A Digital Phase Lock Loop for an External Cavity Diode Laser

    International Nuclear Information System (INIS)

    Wang Xiao-Long; Tao Tian-Jiong; Cheng Bing; Wu Bin; Xu Yun-Fei; Wang Zhao-Ying; Lin Qiang

    2011-01-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad 2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems. (fundamental areas of phenomenology(including applications))

  1. Cervical Cancer Stage IA

    Science.gov (United States)

    ... historical Searches are case-insensitive Cervical Cancer Stage IA Add to My Pictures View /Download : Small: 720x576 ... Large: 3000x2400 View Download Title: Cervical Cancer Stage IA Description: Stage IA1 and IA2 cervical cancer; drawing ...

  2. Cervical Cancer Stage IIIA

    Science.gov (United States)

    ... hyphen, e.g. -historical Searches are case-insensitive Cervical Cancer Stage IIIA Add to My Pictures View /Download : ... 1275x1275 View Download Large: 2550x2550 View Download Title: Cervical Cancer Stage IIIA Description: Stage IIIA cervical cancer; drawing ...

  3. Cervical Cancer—Patient Version

    Science.gov (United States)

    Cervical cancer is the fourth most common cancer in women worldwide. The primary risk factor for cervical cancer is human papillomavirus (HPV) infection. Start here to find evidence-based information on cervical cancer treatment, causes and prevention, screening, research, and statistics.

  4. Cervical Cancer Stage IVA

    Science.gov (United States)

    ... hyphen, e.g. -historical Searches are case-insensitive Cervical Cancer Stage IVA Add to My Pictures View /Download : ... 1575x1200 View Download Large: 3150x2400 View Download Title: Cervical Cancer Stage IVA Description: Stage IVA cervical cancer; drawing ...

  5. Cervical Cancer Stage IVB

    Science.gov (United States)

    ... hyphen, e.g. -historical Searches are case-insensitive Cervical Cancer Stage IVB Add to My Pictures View /Download : ... 1200x1305 View Download Large: 2400x2610 View Download Title: Cervical Cancer Stage IVB Description: Stage IVB cervical cancer; drawing ...

  6. Navigation Study, Colorado Locks, Colorado River, Matagorda, Texas

    National Research Council Canada - National Science Library

    McCollum, Randy

    2000-01-01

    A 1:70 physical navigation model was built to replicate the Matagorda Locks, approximately one mile of the GIWW east of the locks, approximately one-half mile of the Colorado River north of the GIWW...

  7. Spatially resolved detection of mutually locked Josephson junctions in arrays

    International Nuclear Information System (INIS)

    Keck, M.; Doderer, T.; Huebener, R.P.; Traeuble, T.; Dolata, R.; Weimann, T.; Niemeyer, J.

    1997-01-01

    Mutual locking due to the internal coupling in two-dimensional arrays of Josephson junctions was investigated. The appearance of Shapiro steps in the current versus voltage curve of a coupled on-chip detector junction is used to indicate coherent oscillations in the array. A highly coherent state is observed for some range of the array bias current. By scanning the array with a low-power electron beam, mutually locked junctions remain locked while the unlocked junctions generate a beam-induced additional voltage drop at the array. This imaging technique allows the detection of the nonlocked or weakly locked Josephson junctions in a (partially) locked array state. copyright 1997 American Institute of Physics

  8. Plate flexure and volcanism: Late Cenozoic tectonics of the Tabar-Lihir-Tanga-Feni alkalic province, New Ireland Basin, Papua New Guinea

    Science.gov (United States)

    Lindley, I. D.

    2016-05-01

    Late Cenozoic Tabar-Lihir-Tanga-Feni (TLTF) alkaline volcanism, New Ireland Basin, PNG, is associated with extensional cracks along the crests of flexed ridges developed on the New Ireland Microplate (New name). The tectonic alignment of the TLTF volcanic arc is essentially perpendicular to the flexed ridges, suggesting that fractures parallel to the direction of maximum horizontal compression facilitated the rapid ascent of alkaline magmas from the mantle region, perhaps 60-70 km depth. The mainly Pliocene to Pleistocene volcanoes were localized at the intersection of ridge-parallel Kabang structures and arc-parallel Niffin structures, suggesting that the Kabang-Niffin structural intersections underlying each of the TLTF island groups provided a well developed, clustered network of open conduits which tapped the mantle source region. Periodic post-Miocene locking and unlocking along the strike-slip Kilinailau Fault (New name) are thought to have functioned as a valve, turning on (Pliocene) and then turning off (Pleistocene) volcanic activity, respectively. Partial locking of the Kilinailau Fault during the Pliocene resulted in the accumulation of intraplate stresses within the New Ireland Microplate, and caused plate flexure and ridge development, plate-cracking along ridge crests and the development of arc-parallel regional fractures parallel to the direction of maximum compression. Unlocking of the Kilinailau Fault in the Pleistocene resulted in the release of intraplate stresses in the New Ireland Microplate and a cessation of volcanic activity across most of the TLTF arc. The style and scale of plate flexure and cracking, accompanied by within-plate alkaline volcanism from equally spaced ridge-top eruptive centers confined to a narrow, linear volcanic arc are unknown from any other tectonic province.

  9. Treatment of cervical radiculopathy by anterior cervical discectomy and cage fusion

    Directory of Open Access Journals (Sweden)

    Osman A Mohamed

    2012-01-01

    Full Text Available Introduction: Since the pioneering days of the anterior cervical approach introduced by Cloward et al. in the early 1950s, anterior cervical discectomy and fusion (ACDF has been the standard procedure for most discogenic and degenerative cervical spinal lesions. Although traditional interbody fusion using iliac bone can maintain the patency of the neuroforamen and ensure solid fusion, selection of patients, and of surgical procedure for ACDF is a continuous challenge. Aim: The aim of this study was to assess the results of cervical discectomy and fusion with cervical cages in treatment of cervical radiculopathy clinically and radiologically. Materials and Methods: Eighteen patients suffering from cervical radiculopathy were operated upon using this technique. They were 15 males and 3 females. Clinical and radiological assessment, visual analog scale (VAS for neck and arm and modified Oswestery neck disability index (NDI were done preoperatively and at 4 weeks, 3, 6, and 12 months postoperatively. Polyetheretherketone (Peek cages filled with iliac bone graft were used after cervical discectomy. The levels operated upon were C 5-6 in 16 patients and C4-5 in 2 patients. Results: Marked clinical improvement as regard arm and neck pain, and NDI was observed. The pre and post operative mean and standard deviations (SD of the various scores were as follows. VAS for pain in arm reduced from mean of 8 (SD 1.76 to mean 0.4 (SD 0.4, VAS for neck pain reduced from mean of 3.5 (SD 1.58 to mean of 0.8 (SD 0.47, and NDI from mean of 20.2 (SD 0.89 to 2.1(SD 1.05. Fusion occurred in all patients. Subjectively 79% of the patients reported marked improvement in neck pain, and 95% reported marked reduction in arm pain. Conclusion: Anterior cervical discectomy and cage fusion resulted in high fusion rate with minimal preservation of lordosis.

  10. Distracted cervical spinal fusion for management of caudal cervical spondylomyelopathy in large-breed dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ellison, G. W.; Seim, III, H. B.; Clemmons, R. M.

    1988-08-15

    Using an autogenous bone graft (obtained from the iliac crest), 4-mm cancellous bone screws, and polymethylmethacrylate, a distracted cervical spinal fusion technique was performed on 10 dogs with myelographic evidence of caudal cervical spondylomyelopathy. All dogs had evidence of dynamic soft tissue spinal cord compression, as indicated by flexion, extension, and traction myelographic views. Of the 10 dogs, 4 previously had undergone surgery by use of ventral slot or cervical disk fenestration techniques, and their neurologic status had deteriorated after the original surgery. Preoperative neurologic status of the 10 dogs included nonambulatory tetraparesis (n = 5), severe ataxia with conscious proprioceptive deficits (n = 2), and mild ambulatory ataxia with conscious proprioceptive deficits (n = 3). Five dogs had signs of various degrees of cervical pain. Clinical improvement was observed in 8 of 10 dogs--either improved neurologic status or elimination of cervical pain. Implant loosening developed in 3 dogs; 2 of them were euthanatized because of lack of neurologic improvement. Radiographic evidence of bony cervical fusion was observed during a 9- to 24-week period in 6 of the 8 surviving dogs. The distracted cervical fusion technique appears to be a valid surgical procedure to manage cervical spondylomyelopathy in those dogs in which the lesions are limited to one cervical intervertebral disk space.

  11. Distracted cervical spinal fusion for management of caudal cervical spondylomyelopathy in large-breed dogs

    International Nuclear Information System (INIS)

    Ellison, G.W.; Seim, H.B. III; Clemmons, R.M.

    1988-01-01

    Using an autogenous bone graft (obtained from the iliac crest), 4-mm cancellous bone screws, and polymethylmethacrylate, a distracted cervical spinal fusion technique was performed on 10 dogs with myelographic evidence of caudal cervical spondylomyelopathy. All dogs had evidence of dynamic soft tissue spinal cord compression, as indicated by flexion, extension, and traction myelographic views. Of the 10 dogs, 4 previously had undergone surgery by use of ventral slot or cervical disk fenestration techniques, and their neurologic status had deteriorated after the original surgery. Preoperative neurologic status of the 10 dogs included nonambulatory tetraparesis (n = 5), severe ataxia with conscious proprioceptive deficits (n = 2), and mild ambulatory ataxia with conscious proprioceptive deficits (n = 3). Five dogs had signs of various degrees of cervical pain. Clinical improvement was observed in 8 of 10 dogs--either improved neurologic status or elimination of cervical pain. Implant loosening developed in 3 dogs; 2 of them were euthanatized because of lack of neurologic improvement. Radiographic evidence of bony cervical fusion was observed during a 9- to 24-week period in 6 of the 8 surviving dogs. The distracted cervical fusion technique appears to be a valid surgical procedure to manage cervical spondylomyelopathy in those dogs in which the lesions are limited to one cervical intervertebral disk space

  12. Cervical Cancer Stage IB

    Science.gov (United States)

    ... hyphen, e.g. -historical Searches are case-insensitive Cervical Cancer Stage IB Add to My Pictures View /Download : ... 1613x1200 View Download Large: 3225x2400 View Download Title: Cervical Cancer Stage IB Description: Stage IB1 and IB2 cervical ...

  13. Comparación biomecánica entre los sistemas convencionales y uni-lock en osteosíntesis del ángulo mandibular: Estudio fotoelástico Biomechanical comparison of the conventional and uni-lock systems for mandibular osteosynthesis: A photoelastic study

    Directory of Open Access Journals (Sweden)

    José Luis Cebrián-Carretero

    2012-03-01

    Full Text Available Introducción: Las implicaciones biomecánicas de la interacción de las placas y tornillos de titanio con la mandíbula fracturada no son del todo conocidas. Los modelos matemáticos desarrollados hasta hoy en día muestran ciertas limitaciones, y los estudios experimentales han fracasado en reproducir las fuerzas musculares y la distribución de las tensiones internas en la interfaz entre mandíbula e implante. Material y métodos: En el presente estudio, empleamos un simulador estático del sistema músculo-esquelético masticatorio para demostrar en réplicas mandibulares de resina epoxi, por medio de la fotoelasticidad tridimensional, la distribución de tensiones que se produce en fracturas del cuerpo mandibular tras la aplicación de diferentes métodos de osteosíntesis. Resultados: Los resultados muestran que el simulador y la fotoelasticidad 3D son útiles para estudiar las interacciones entre el hueso y el material de osteosíntesis. Los sistemas «lock» o bloqueados reflejaron la distribución de tensiones más favorable en la mandíbula de resina epoxi fracturada. Conclusiones: La fotoelasticidad tridimensional en modelos de resina epoxi es un método útil para evaluar la distribución de tensiones en una estructura para estudios biomecánicos. En lo que se refiere a la osteosíntesis mandibular, las placas tipo «lock» mostraron ser las menos agresivas para el hueso.Introduction: The biomechanical effects of the interaction between titanium plates and screws and the fractured mandible are not well known. The mathematical models that have been developed to date show limitations and the experimental studies fail in reproducing muscle forces and internal stress distributions in the bone-implant interface with the mandibular structure. Material and methods: In the present study we use a static simulator of the masticatory system to show, in epoxy resin mandibular models, by means of 3D (three-dimensional photoelasticity, the stress

  14. Neural Network Prediction of Disruptions Caused by Locked Modes on J-TEXT Tokamak

    International Nuclear Information System (INIS)

    Ding Yonghua; Jin Xuesong; Chen Zhenzhen; Zhuang Ge

    2013-01-01

    Prediction of disruptions caused by locked modes using the Back-Propagation (BP) neural network is completed on J-TEXT tokamak. The network, which is based on the BP neural network, uses Mirnov coils and locked mode coils signals as input data, and outputs a signal including information of prediction of locked mode. The rate of successful prediction of locked modes is more than 90%. For intrinsic locked mode disruptions, the network can give a prewarning signal about 1 ms ahead of the locking-time. For the disruption caused by resonant magnetic perturbation (RMPs) locked modes, the network can give a prewarning signal about 10 ms ahead of the locking-time

  15. Technique for Determining Lock Coefficient of Differential "Quif"

    Directory of Open Access Journals (Sweden)

    A. B. Fominyh

    2015-01-01

    Full Text Available Increasing the traction qualities of cars on the black ice and snow-covered roads is a relevant task. There are two ways to solve this task, i.e. optimize distribution of the power stream between the driving wheels of the car; introduce a differential (differentials of the increased friction in transmission.Now, an installation of the increased friction differential in transmission is the most widespread measure to increase traction properties of cars. The differential of design "Quif" is one of such differentials. To estimate the efficiency degree of using such a differential is possible either experimentally or theoretically. In case of theoretically determined usefulness of this differential design, as an estimate indicator of the differential installation in transmission a coefficient of lock is accepted.The article considers an algorithm and a technique to calculate a lock coefficient of the differential design "Quif" allowing us to define numeric values of the lock coefficient of such differential at designing stage. It also considers how the lock coefficient depends on the gearing angle and tilt angle of the gear wheel teeth of differential. The given estimating algorithm of designated parameter of differential has more logical and compact structure with regard to the known ones. The lock coefficient values calculated by the offered technique differ from the experimental data by no more than 12%. Taking into account abovementioned, the presented technique for calculating lock coefficient of differential "Quif" is advisable for practical application.

  16. Locked-in: the syndrome as depicted in literature.

    Science.gov (United States)

    Haan, Joost

    2013-01-01

    Protagonists who are locked-in can be found throughout fiction, probably because being locked-in serves as a strong philosophical metaphor for human existence. In this chapter, three protagonists who are locked-in due to physical/medical reasons will be described. The fictitious stories of Noirtier from The Count of Monte Cristo by Alexandre Dumas and that of Madame Raquin from Thérèse Raquin by Émile Zola are followed by the real-life story of Jean-Dominique Bauby's The Diving Bell and the Butterfly. Dumas' Noirtier is considered the first description of the locked-in syndrome in literature, and Madame Raquin appears to be locked-in also, but her description leaves many questions. Bauby's autopathography is chosen from many several similar discourses as it contains cross-references to Noirtier, Dumas' prototype of the syndrome, but also because it is of high literary value. The similarities and remarkable differences between these three case reports of this existentialistically important state of being will be highlighted, with an emphasis on the focus of their narratives. © 2013 Elsevier B.V. All rights reserved.

  17. APR1400 Locked Rotor Transient Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun

    2007-01-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR

  18. APR1400 Locked Rotor Transient Analysis using KNAP

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR.

  19. Active stabilization of a diode laser injection lock

    Energy Technology Data Exchange (ETDEWEB)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep [Department of Physics, University of Washington, P.O. Box 351560, Seattle, Washington 98195-1560 (United States)

    2016-06-15

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  20. Active stabilization of a diode laser injection lock

    International Nuclear Information System (INIS)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  1. Design and Performance Test of Locking Curved-Nut

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Min Cheol; Kang, Ho Sung; Kim, Do Yeop; Lee, Suk Yong; Lee, Eung Suk [Chungbuk Nat’l Univ., Cheongju (Korea, Republic of); Jeong, Hui Jong [Viblock Company, Cheongwon (Korea, Republic of)

    2017-03-15

    Many types of locking nut are commercializing in the various industries where has heavy vibration. Because Nut's loosing causes a serious accident. But the most locking nuts are too expensive as the complicate manufacturing process. In this study, we design the new type of locking nut, 'Curved-Nut' that is relatively simple making process. We study a relation between the elastic energy and the nut loosing mechanism. So it is analysed, the elastic energy of Curved-Nut comparing with the locking test. The Curved-Nut was manufactured on the commercial nut using a milling tool with horizontal cutting, one or two time under the nut. As the result, the more elastic energy the more prevent the loosing of the nut. We verified the performance of the loosing nut using the vibration testing equipment (NAS3350).

  2. Physics and Control of Locked Modes in the DIII-D Tokamak

    International Nuclear Information System (INIS)

    Volpe, Francesco

    2017-01-01

    This Final Technical Report summarizes an investigation, carried out under the auspices of the DOE Early Career Award, of the physics and control of non-rotating magnetic islands (''locked modes'') in tokamak plasmas. Locked modes are one of the main causes of disruptions in present tokamaks, and could be an even bigger concern in ITER, due to its relatively high beta (favoring the formation of Neoclassical Tearing Mode islands) and low rotation (favoring locking). For these reasons, this research had the goal of studying and learning how to control locked modes in the DIII-D National Fusion Facility under ITER-relevant conditions of high pressure and low rotation. Major results included: the first full suppression of locked modes and avoidance of the associated disruptions; the demonstration of error field detection from the interaction between locked modes, applied rotating fields and intrinsic errors; the analysis of a vast database of disruptive locked modes, which led to criteria for disruption prediction and avoidance.

  3. Physics and Control of Locked Modes in the DIII-D Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Volpe, Francesco [Columbia Univ., New York, NY (United States). Dept. of Applied Physics and Applied Mathematics

    2017-01-30

    This Final Technical Report summarizes an investigation, carried out under the auspices of the DOE Early Career Award, of the physics and control of non-rotating magnetic islands (“locked modes”) in tokamak plasmas. Locked modes are one of the main causes of disruptions in present tokamaks, and could be an even bigger concern in ITER, due to its relatively high beta (favoring the formation of Neoclassical Tearing Mode islands) and low rotation (favoring locking). For these reasons, this research had the goal of studying and learning how to control locked modes in the DIII-D National Fusion Facility under ITER-relevant conditions of high pressure and low rotation. Major results included: the first full suppression of locked modes and avoidance of the associated disruptions; the demonstration of error field detection from the interaction between locked modes, applied rotating fields and intrinsic errors; the analysis of a vast database of disruptive locked modes, which led to criteria for disruption prediction and avoidance.

  4. Shape Memory Alloy (SMA)-Based Launch Lock

    Science.gov (United States)

    Badescu, Mircea; Bao, Xiaoqi; Bar-Cohen, Yoseph

    2014-01-01

    Most NASA missions require the use of a launch lock for securing moving components during the launch or securing the payload before release. A launch lock is a device used to prevent unwanted motion and secure the controlled components. The current launch locks are based on pyrotechnic, electro mechanically or NiTi driven pin pullers and they are mostly one time use mechanisms that are usually bulky and involve a relatively high mass. Generally, the use of piezoelectric actuation provides high precession nanometer accuracy but it relies on friction to generate displacement. During launch, the generated vibrations can release the normal force between the actuator components allowing shaft's free motion which could result in damage to the actuated structures or instruments. This problem is common to other linear actuators that consist of a ball screw mechanism. The authors are exploring the development of a novel launch lock mechanism that is activated by a shape memory alloy (SMA) material ring, a rigid element and an SMA ring holding flexure. The proposed design and analytical model will be described and discussed in this paper.

  5. Cervical spine motion in manual versus Jackson table turning methods in a cadaveric global instability model.

    Science.gov (United States)

    DiPaola, Matthew J; DiPaola, Christian P; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Bloch, David; Rechtine, Glenn R

    2008-06-01

    A study of spine biomechanics in a cadaver model. To quantify motion in multiple axes created by transfer methods from stretcher to operating table in the prone position in a cervical global instability model. Patients with an unstable cervical spine remain at high risk for further secondary injury until their spine is adequately surgically stabilized. Previous studies have revealed that collars have significant, but limited benefit in preventing cervical motion when manually transferring patients. The literature proposes multiple methods of patient transfer, although no one method has been universally adopted. To date, no study has effectively evaluated the relationship between spine motion and various patient transfer methods to an operating room table for prone positioning. A global instability was surgically created at C5-6 in 4 fresh cadavers with no history of spine pathology. All cadavers were tested both with and without a rigid cervical collar in the intact and unstable state. Three headrest permutations were evaluated Mayfield (SM USA Inc), Prone View (Dupaco, Oceanside, CA), and Foam Pillow (OSI, Union City, CA). A trained group of medical staff performed each of 2 transfer methods: the "manual" and the "Jackson table" transfer. The manual technique entailed performing a standard rotation of the supine patient on a stretcher to the prone position on the operating room table with in-line manual cervical stabilization. The "Jackson" technique involved sliding the supine patient to the Jackson table (OSI, Union City, CA) with manual in-line cervical stabilization, securing them to the table, then initiating the table's lock and turn mechanism and rotating them into a prone position. An electromagnetic tracking device captured angular motion between the C5 and C6 vertebral segments. Repeated measures statistical analysis was performed to evaluate the following conditions: collar use (2 levels), headrest (3 levels), and turning technique (2 levels). For all

  6. Phase locking of vortex cores in two coupled magnetic nanopillars

    Directory of Open Access Journals (Sweden)

    Qiyuan Zhu

    2014-11-01

    Full Text Available Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. This work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.

  7. Non-contiguous spinal injury in cervical spinal trauma: evaluation with cervical spine MRI

    International Nuclear Information System (INIS)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon; Bae, Sang Jin

    2004-01-01

    We wished to evaluate the incidence of non-contiguous spinal injury in the cervicothoracic junction (CTJ) or the upper thoracic spines on cervical spinal MR images in the patients with cervical spinal injuries. Seventy-five cervical spine MR imagings for acute cervical spinal injury were retrospectively reviewed (58 men and 17 women, mean age: 35.3, range: 18-81 years). They were divided into three groups based on the mechanism of injury; axial compression, hyperflexion or hyperextension injury, according to the findings on the MR and CT images. On cervical spine MR images, we evaluated the presence of non-contiguous spinal injury in the CTJ or upper thoracic spine with regard to the presence of marrow contusion or fracture, ligament injury, traumatic disc herniation and spinal cord injury. Twenty-one cases (28%) showed CTJ or upper thoracic spinal injuries (C7-T5) on cervical spinal MR images that were separated from the cervical spinal injuries. Seven of 21 cases revealed overt fractures in the CTJs or upper thoracic spines. Ligament injury in these regions was found in three cases. Traumatic disc herniation and spinal cord injury in these regions were shown in one and two cases, respectively. The incidence of the non-contiguous spinal injuries in CTJ or upper thoracic spines was higher in the axial compression injury group (35.5%) than in the hyperflexion injury group (26.9%) or the hyperextension (25%) injury group. However, there was no statistical significance (ρ > 0.05). Cervical spinal MR revealed non-contiguous CTJ or upper thoracic spinal injuries in 28% of the patients with cervical spinal injury. The mechanism of cervical spinal injury did not significantly affect the incidence of the non-contiguous CTJ or upper thoracic spinal injury

  8. Non-contiguous spinal injury in cervical spinal trauma: evaluation with cervical spine MRI

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Bae, Sang Jin [Sanggyepaik Hospital, Inje University, Seoul (Korea, Republic of)

    2004-12-15

    We wished to evaluate the incidence of non-contiguous spinal injury in the cervicothoracic junction (CTJ) or the upper thoracic spines on cervical spinal MR images in the patients with cervical spinal injuries. Seventy-five cervical spine MR imagings for acute cervical spinal injury were retrospectively reviewed (58 men and 17 women, mean age: 35.3, range: 18-81 years). They were divided into three groups based on the mechanism of injury; axial compression, hyperflexion or hyperextension injury, according to the findings on the MR and CT images. On cervical spine MR images, we evaluated the presence of non-contiguous spinal injury in the CTJ or upper thoracic spine with regard to the presence of marrow contusion or fracture, ligament injury, traumatic disc herniation and spinal cord injury. Twenty-one cases (28%) showed CTJ or upper thoracic spinal injuries (C7-T5) on cervical spinal MR images that were separated from the cervical spinal injuries. Seven of 21 cases revealed overt fractures in the CTJs or upper thoracic spines. Ligament injury in these regions was found in three cases. Traumatic disc herniation and spinal cord injury in these regions were shown in one and two cases, respectively. The incidence of the non-contiguous spinal injuries in CTJ or upper thoracic spines was higher in the axial compression injury group (35.5%) than in the hyperflexion injury group (26.9%) or the hyperextension (25%) injury group. However, there was no statistical significance ({rho} > 0.05). Cervical spinal MR revealed non-contiguous CTJ or upper thoracic spinal injuries in 28% of the patients with cervical spinal injury. The mechanism of cervical spinal injury did not significantly affect the incidence of the non-contiguous CTJ or upper thoracic spinal injury.

  9. Locked nucleic acid

    DEFF Research Database (Denmark)

    Jepsen, Jan Stenvang; Sørensen, Mads D; Wengel, Jesper

    2004-01-01

    Locked nucleic acid (LNA) is a class of nucleic acid analogs possessing very high affinity and excellent specificity toward complementary DNA and RNA, and LNA oligonucleotides have been applied as antisense molecules both in vitro and in vivo. In this review, we briefly describe the basic...

  10. Clinical study of intermittent lock of the temporomandibular joint. Relation to frequency of intermittent lock on clinical examination and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Takashi; Nagai, Itaru; Miyazaki, Akihiro; Yamaguchi, Akira; Kohama, Geniku [Sapporo Medical Univ. (Japan). School of Medicine

    2002-03-01

    To examine the occurrence of intermittent lock, we investigated the correlation between the frequency of intermittent lock of the temporomandibular joint and magnetic resonance imaging (MRI) findings. The subjects consisted of 25 patients (25 joints) with unilateral intermittent lock who were treated from April 1994 through March 2000 at our department. MRI examination of the joint was performed on the affected side. We divided the patients into two groups: a high-frequency group consisting of 15 patients who had symptoms of intermittent lock every day and a low-frequency group consisting of 10 patients who did not have symptoms every day. The results showed no statistical difference between the two groups in clinical findings such as age, sex, clicking side of the joint, duration of intermittent lock, method of unlocking, muscle pain on palpation, degree of maximal mouth opening, distance between the maxillary and mandibular tooth midline, or the degree of overbite and overjet. However, the two groups differed significantly in the degree of anterior disc displacement as assessed by MRI. (author)

  11. 49 CFR 236.16 - Electric lock, main track releasing circuit.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock, main track releasing circuit. 236... Rules and Instructions: All Systems General § 236.16 Electric lock, main track releasing circuit. When an electric lock releasing circuit is provided on the main track to permit a train or an engine to...

  12. Discretely tunable micromachined injection-locked lasers

    International Nuclear Information System (INIS)

    Cai, H; Yu, M B; Lo, G Q; Kwong, D L; Zhang, X M; Liu, A Q; Liu, B

    2010-01-01

    This paper reports a micromachined injection-locked laser (ILL) to provide tunable discrete wavelengths. It utilizes a non-continuously tunable laser as the master to lock a Fabry–Pérot semiconductor laser chip. Both lasers are integrated into a deep-etched silicon chip with dimensions of 3 mm × 3 mm × 0.8 mm. Based on the experimental results, significant improvements in the optical power and spectral purity have been achieved in the fully locked state, and optical hysteresis and bistability have also been observed in response to the changes of the output wavelength and optical power of the master laser. As a whole system, the micromachined ILL is able to provide single mode, discrete wavelength tuning, high power and direct modulation with small size and single-chip solution, making it promising for advanced optical communications such as wavelength division multiplexing optical access networks.

  13. Isolation of Melittin from Iranian Honey Bee Venom and Investigation of Its Effect on Proliferation of Cervical Cancer- HeLa Cell Line

    Directory of Open Access Journals (Sweden)

    K Pooshang Bagheri

    2013-06-01

    Full Text Available Introduction: Cervical cancer is the second prevalent cancer in developing countries and the sixth prevalent cancer in USA. Since conventional treatment methods are associated with detrimental side effects, searching for new drugs using natural ingredients is very important. Previous studies have shown that melittin (main component of honey bee venom has anticancer properties along with the effect on cell membrane and activation of apoptosis. In this study, inhibitory effects of melittin on the viability and proliferation of cervical cancer cell line (HeLa was investigated. Methods: Melittin was purified from honeybee venom using reversed-phase HPLC method. Then, biological activity of melittin was examined by hemolytic activity analysis on the red blood cells. In order to investigate whether melittin inhibits proliferation of HeLa cell, MTT assay was performed. HeLa cells were plated in a 96-well plate and treated with serially diluted concentrations of melittin for 12 and 24 hours. The viability of the cells was measured via MTT assay at 540nm. Results: Melittin showed a strong hemolytic activity (HD50=0.5 µg/ml which can be reduced by FBS(HD50=2 µg/ml. Results of MTT assay indicated that melittin shows cytotoxic effect on cervical cancer cells with IC50 = 1.2 ug/ml at 12h incubation period. Conclusion: In this study, biological activity of melittin and inhibitory effect of FBS on hemolysis were determined via hemolytic activity analysis. MTT assay indicated that melittin induced cytotoxic effects in a dose dependent manner on cervical cancer cells and it also revealed dependence on incubation time as well.

  14. An Evaluation of Coarse-Grained Locking for Multicore Microkernels

    OpenAIRE

    Elphinstone, Kevin; Zarrabi, Amirreza; Danis, Adrian; Shen, Yanyan; Heiser, Gernot

    2016-01-01

    The trade-off between coarse- and fine-grained locking is a well understood issue in operating systems. Coarse-grained locking provides lower overhead under low contention, fine-grained locking provides higher scalability under contention, though at the expense of implementation complexity and re- duced best-case performance. We revisit this trade-off in the context of microkernels and tightly-coupled cores with shared caches and low inter-core migration latencies. We evaluate performance on ...

  15. Past, Present, Future Erosion at Locke Island

    Energy Technology Data Exchange (ETDEWEB)

    Bjornstad, Bruce N.

    2006-08-08

    This report describes and documents the erosion that has occurred along the northeast side of Locke Island over the last 10 to 20 years. The principal cause of this erosion is the massive Locke Island landslide complex opposite the Columbia River along the White Bluffs, which constricts the flow of the river and deflects the river's thalweg southward against the island.

  16. Non-destructive test of lock actuator component using neutron radiography technique

    International Nuclear Information System (INIS)

    Juliyanti; Setiawan; Sutiarso

    2012-01-01

    Non-destructive test of lock actuator using neutron radiography technique has been done. The lock actuator is a mechanical system which is controlled by central lock module consisting of electronic circuit which drives the lock actuator works accordingly to open and lock the vehicle door. The non-destructive test using neutron radiography is carried out to identify the type of defect is presence by comparing between the broken and the brand new one. The method used to test the lock actuator component is film method (direct method). The result show that the radiography procedure has complied with the ASTM standard for neutron radiography with background density of 2.2, 7 lines and 3 holes was seen in the sensitivity indicator (SI) and the quite good image quality was obtained. In the brand new actuator is seen that isolator part which separated the coils has melted. By this non-destructive test using neutron radiography technique is able to detect in early stage the type of component's defect inside the lock actuator without to dismantle it. (author)

  17. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    Science.gov (United States)

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  18. Clinical and microbiologic effects of lingual cervical coverage by removable partial dentures.

    Science.gov (United States)

    Ao, Aiichiro; Wakabayashi, Noriyuki; Nitta, Hiroshi; Igarashi, Yoshimasa

    2013-01-01

    The effect of gingival coverage by removable partial dentures (RPDs) on bacterial accumulation has not been sufficiently established. The aim of this study was to evaluate the periodontal and microbiologic reactions to mandibular major connectors. It was hypothesized that the use of a lingual plate increases the risk of periodontal disease. Fourteen subjects (mean age: 69.0 years) received oral hygiene instructions and ultrasonic debridement prior to examination. Each subject received an experimental RPD incorporating either a lingual bar or lingual plate for the first 8 weeks and was then switched to the other option for the next 8 weeks. Clinical parameters (Plaque Index, Gingival Index, probing depth, and tooth mobility) were recorded. Subgingival plaque samples were collected from the periodontal pocket in the test site to measure the colonization of periodontal pathogens after the use of each denture. The mean probing depth was significantly greater after use of the lingual plate compared to the lingual bar (P bacterial species showed smaller numbers of microorganisms at the second examination than at the first. The lingual cervical coverage did not precipitate the accumulation of anaerobic microorganisms, although it could potentially induce gingival inflammation. The results suggest that a lingual plate can be used as safely as a lingual bar if oral and denture hygiene are carefully monitored.

  19. Temperature-insensitive laser frequency locking near absorption lines

    International Nuclear Information System (INIS)

    Kostinski, Natalie; Olsen, Ben A.; Marsland, Robert III; McGuyer, Bart H.; Happer, William

    2011-01-01

    Combined magnetically induced circular dichroism and Faraday rotation of an atomic vapor are used to develop a variant of the dichroic atomic vapor laser lock that eliminates lock sensitivity to temperature fluctuations of the cell. Operating conditions that eliminate first-order sensitivity to temperature fluctuations can be determined by low-frequency temperature modulation. This temperature-insensitive gyrotropic laser lock can be accurately understood with a simple model, that is in excellent agreement with observations in potassium vapor at laser frequencies in a 2 GHz range about the 770.1 nm absorption line. The methods can be readily adapted for other absorption lines.

  20. Tilt-tuned etalon locking for tunable laser stabilization.

    Science.gov (United States)

    Gibson, Bradley M; McCall, Benjamin J

    2015-06-15

    Locking to a fringe of a tilt-tuned etalon provides a simple, inexpensive method for stabilizing tunable lasers. Here, we describe the use of such a system to stabilize an external-cavity quantum cascade laser; the locked laser has an Allan deviation of approximately 1 MHz over a one-second integration period, and has a single-scan tuning range of approximately 0.4  cm(-1). The system is robust, with minimal alignment requirements and automated lock acquisition, and can be easily adapted to different wavelength regions or more stringent stability requirements with minor alterations.

  1. Testing ultrafast mode-locking at microhertz relative optical linewidth.

    Science.gov (United States)

    Martin, Michael J; Foreman, Seth M; Schibli, T R; Ye, Jun

    2009-01-19

    We report new limits on the phase coherence of the ultrafast mode-locking process in an octave-spanning Ti:sapphire comb.We find that the mode-locking mechanism correlates optical phase across a full optical octave with less than 2.5 microHZ relative linewidth. This result is at least two orders of magnitude below recent predictions for quantum-limited individual comb-mode linewidths, verifying that the mode-locking mechanism strongly correlates quantum noise across the comb spectrum.

  2. Testing ultrafast mode-locking at microhertz relative optical linewidth

    OpenAIRE

    Martin, Michael J.; Foreman, Seth M.; Schibli, T. R.; Ye, Jun

    2008-01-01

    We report new limits on the phase coherence of the ultrafast mode-locking process in an octave-spanning Ti:sapphire comb. We find that the mode-locking mechanism correlates optical phase across a full optical octave with less than 2.5 micro Hz relative linewidth. This result is at least two orders of magnitude below recent predictions for quantum-limited individual comb-mode linewidths, verifying that the mode-locking mechanism strongly correlates quantum noise across the comb spectrum.

  3. Locking a molecular bond: A case study of CsI

    DEFF Research Database (Denmark)

    Szakács, Tamás; Amstrup, Bjarne; Gross, Peter

    1994-01-01

    This paper treats the problem of locking a molecular bond at a length other than the equilibrium distance, with the help of optical electric fields. Locking conditions for single-color fields are examined, and slowly decaying locked wave functions are sought. These were functions are then used...... as target functions in an optimal control procedure. The resultant solution is an optimal field that creates a wave function as close as possible to the target function, followed by the application of a locking single-color field that can keep a large part of this wave function at the given position...

  4. Roller Locking Brake

    Science.gov (United States)

    Vranish, John M.

    1993-01-01

    Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

  5. Detecting cervical cancer by quantitative promoter hypermethylation assay on cervical scrapings : A feasibility study

    NARCIS (Netherlands)

    Reesink-Peters, N; Wisman, G.B.A.; Jeronimo, C; Tokumaru, CY; Cohen, Y; Dong, SM; Klip, HG; Buikema, HJ; Suurmeijer, AJH; Hollema, H; Boezen, HM; Sidransky, D; van der Zee, AGJ

    Current morphology-based cervical cancer screening is associated with significant false-positive and false-negative results. Tumor suppressor gene hypermethylation is frequently present in cervical cancer. It is unknown whether a cervical scraping reflects the methylation status of the underlying

  6. Cervical Cancer Screening

    Science.gov (United States)

    ... Cancer found early may be easier to treat. Cervical cancer screening is usually part of a woman's health ... may do more tests, such as a biopsy. Cervical cancer screening has risks. The results can sometimes be ...

  7. Prevent Cervical Cancer

    Science.gov (United States)

    ... professional printing [PDF-1.5MB] Cancer Home “Prevent Cervical Cancer” Infographic Language: English Español (Spanish) Recommend on Facebook Tweet Share Compartir Prevent Cervical Cancer with the Right Test at the Right Time ...

  8. Locking screw apparatus and method for underwater remote replacement

    International Nuclear Information System (INIS)

    Balog, L.J.

    1987-01-01

    A method is described for locking in place a screw which secures together first and second structures in the internal region of a nuclear reactor core. The first structure has a screw bore with a counterbore portion formed in an outer surface. The method comprises the steps of: forming a lateral recess in the counterbore portion and spaced from the outer surface, providing an elongated screw having an enlarged shoulder flange and an angular drive head with a lateral width substantially less than that of the counterbore portion, disposing the screw through the screw bore in threaded engagement with the second structure and with the shoulder rotatably seated in the counterbore portion. This provides a locking member having an angular opening and disposing it in the counterbore portion against the flange with the drive head received in the opening for engagement with the locking member to prevent rotation. This deforms a portion of the locking member into the recess for engagement to prevent movement of the locking member with respect to the first structure

  9. Evolution of the Generic Lock System at Jefferson Lab

    International Nuclear Information System (INIS)

    Brian Bevins; Yves Roblin

    2003-01-01

    The Generic Lock system is a software framework that allows highly flexible feedback control of large distributed systems. It allows system operators to implement new feedback loops between arbitrary process variables quickly and with no disturbance to the underlying control system. Several different types of feedback loops are provided and more are being added. This paper describes the further evolution of the system since it was first presented at ICALEPCS 2001 and reports on two years of successful use in accelerator operations. The framework has been enhanced in several key ways. Multiple-input, multiple-output (MIMO) lock types have been added for accelerator orbit and energy stabilization. The general purpose Proportional-Integral-Derivative (PID) locks can now be tuned automatically. The generic lock server now makes use of the Proxy IOC (PIOC) developed at Jefferson Lab to allow the locks to be monitored from any EPICS Channel Access aware client. (Previously clients had to be Cdev aware.) The dependency on the Qt XML parser has been replaced with the freely available Xerces DOM parser from the Apache project

  10. Weak-light phase locking for LISA

    International Nuclear Information System (INIS)

    McNamara, Paul W

    2005-01-01

    The long armlengths of the LISA interferometer, and the finite aperture of the telescope, lead to an optical power attenuation of ∼10 -10 of the transmitted to received light. Simple reflection at the end of the arm is therefore not an optimum interferometric design. Instead, a local laser is offset phase locked to the weak incoming beam, transferring the phase information of the incoming to the outgoing light. This paper reports on an experiment to characterize a weak-light phase-locking scheme suitable for LISA in which a diode-pumped, Nd:YAG, non-planar ring oscillator (NPRO) is offset phase locked to a low-power (13 pW) frequency stabilized master NPRO. Preliminary results of the relative phase noise of the slave laser shows shot noise limited performance above 0.4 Hz. Excess noise is observed at lower frequencies, most probably due to thermal effects in the optical arrangement and phase-sensing electronics

  11. SWITCHED REFERENCE PHASE LOCK LOOP (SRPLL)

    International Nuclear Information System (INIS)

    KERNER, T.

    2001-01-01

    The Brookhaven National Laboratory Relativistic Heavy Ion Collider (RHIC) has two beam synchronous event links (BSL), one for each ring, which use the 28 MHz ring low level rf to distribute event codes synchronously with a precise phase relationship to the beam. During a cogging reset just before injection, the low level rf sine wave is interrupted which causes the BSL receivers to lose lock. Lock loss in turn causes false triggers and other undesirable-effects on the beam position monitors (BPM), ionization profile monitors (IPM), the tune meter and various experiments which use the BSLs. To rectify these problems, a SRPLL has been inserted between the beam synchronous master and the low level rf source. The SRPLL inserts a frequency and phase continuous splice over the dead-band gap in the rf source created during a cogging reset. The splice removes the gap and prevents the distributed BSL receivers from losing lock

  12. Association between cervical screening and prevention of invasive cervical cancer in Ontario: a population-based case-control study.

    Science.gov (United States)

    Vicus, Danielle; Sutradhar, Rinku; Lu, Yan; Kupets, Rachel; Paszat, Lawrence

    2015-01-01

    The aim of this study was to estimate the effect of cervical screening in the prevention of invasive cervical cancer among age groups, using a population-based case-control study in the province of Ontario, Canada. Exposure was defined as cervical cytology history greater than 3 months before the diagnosis date of cervical cancer (index date). Cases were women who were diagnosed with cervical cancer between January 1, 1998, and December 31, 2008. Controls were women without a diagnosis of cervical cancer on, or before, December 31, 2008. Two controls were matched to each case on year of birth and income quintile, as of the index date. Conditional logistic regression was used to estimate the odds ratio for having been screened among those with cervical cancer. Cervical cancer screening performed between 3 and 36 months before the index date was protective against invasive cervical cancer in women aged 40 through 69 years. In women younger than 40 years, cervical cancer screening performed 3 to 36 months before the index date was not protective. Cervical screening is associated with a reduced risk for invasive cervical cancer among women older than 40 years. Cervical cancer resources should be focused on maximizing the risk reduction.

  13. Automatic locking knee brace joint

    Science.gov (United States)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  14. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  15. CT-guided cervical interlaminar epidural steroid injection for cervical radiculopathy

    International Nuclear Information System (INIS)

    Chen Wei; Wu Chungen; Wu Chaoxian; Cheng Yongde

    2009-01-01

    Objective: To evaluate the safety and effectiveness of CT-guided cervical interlaminar epidural steroid injection for the treatment of cervical radiculopathy. Methods: CT-guided cervical interlaminar epidural steroid injection was performed in 32 patients with cervical radioculopathy, encountered during the period of Dec. 2006 to June 2008, as the patients failed to respond to the conservative treatment in 2 weeks. The clinical data and the imaging findings were retrospectively analyzed. Before and after the procedure, visual analogue scale (VAS) and Odom criteria were used to evaluate the pain of the patient. Results: Three months after the injection, improvement judged by Odom criteria was seen in 28 patients (87.5%), and the mean pain relief value of VAS was 5.88 ± 1.10. No significant difference in effective rate and in VAS score (P>0.05) was found between protrusion group and degenerative group, between the group with the course over 6 months and the group with the course below 6 months, also between the group receiving one injection and the group receiving the second injection. Conclusion: CT-guided fine needle (23 gauge) puncture epidural steroid (Decadron) 'target spot' injection is an ideal alternative for the treatment of cervical radiculopathy, especially for the patients who fails to respond to the conservative treatment. (authors)

  16. Peak-locking reduction for particle image velocimetry

    International Nuclear Information System (INIS)

    Michaelis, Dirk; Wieneke, Bernhard; Neal, Douglas R

    2016-01-01

    A parametric study of the factors contributing to peak-locking, a known bias error source in particle image velocimetry (PIV), is conducted using synthetic data that are processed with a state-of-the-art PIV algorithm. The investigated parameters include: particle image diameter, image interpolation techniques, the effect of asymmetric versus symmetric window deformation, number of passes and the interrogation window size. Some of these parameters are found to have a profound effect on the magnitude of the peak-locking error. The effects for specific PIV cameras are also studied experimentally using a precision turntable to generate a known rotating velocity field. Image time series recorded using this experiment show a linear range of pixel and sub-pixel shifts ranging from 0 to  ±4 pixels. Deviations in the constant vorticity field (ω z ) reveal how peak-locking can be affected systematically both by varying parameters of the detection system such as the focal distance and f -number, and also by varying the settings of the PIV analysis. A new a priori technique for reducing the bias errors associated with peak-locking in PIV is introduced using an optical diffuser to avoid undersampled particle images during the recording of the raw images. This technique is evaluated against other a priori approaches using experimental data and is shown to perform favorably. Finally, a new a posteriori anti peak-locking filter (APLF) is developed and investigated, which shows promising results for both synthetic data and real measurements for very small particle image sizes. (paper)

  17. Biologia molecular do câncer cervical Molecular biology of cervical cancer

    Directory of Open Access Journals (Sweden)

    Waldemar Augusto Rivoire

    2006-01-01

    Full Text Available A carcinogênese é um processo de múltiplas etapas. Alterações no equilíbrio citogenético ocorrem na transformação do epitélio normal a câncer cervical. Numerosos estudos apoiam a hipótese de que a infecção por HPV está associada com o desenvolvimento de alterações malignas e pré-malignas do trato genital inferior. Neste trabalho são apresentadas as bases para a compreensão da oncogênese cervical. O ciclo celular é controlado por proto-oncogenes e genes supressores. Quando ocorrem mutações, proto-oncogenes tornam-se oncogenes, que são carcinogênicos e causam multiplicação celular excessiva. A perda da ação de genes supressores funcionais pode levar a célula ao crescimento inadequado. O ciclo celular também pode ser alterado pela ação de vírus, entre eles o HPV (Human Papiloma Virus, de especial interesse na oncogênese cervical. Os tipos de HPV 16 e 18 são os de maior interesse, freqüentemente associados a câncer cervical e anal. O conhecimento das bases moleculares que estão envolvidas na oncogênese cervical tem sido possível devido a utilização de técnicas avançadas de biologia molecular. A associação destas técnicas aos métodos diagnósticos clássicos, poderão levar a uma melhor avaliação das neoplasias cervicais e auxiliar no desenvolvimento de novas terapias, talvez menos invasivas e mais efetivas.Carcinogenesis involves several steps. Disorders of the cytogenetic balance occur during the evolution from normal epithelium to cervical cancer. Several studies support the hypothesis that the Human Papiloma Virus (HPV infection is associated to development of premalignant and malignant lesions of cervical cancer. In this review we show the basis to understand cervical oncogenesis. The cell cycle is controlled by protooncogenes and supressive genes. This orchestrated cell cycle can be affected by virus such as HPV. Of special interest in the cervical carcinogenesis are the HPV subtypes 16 and 18

  18. Assessment of cervical range of motion, cervical core strength and scapular dyskinesia in violin players.

    Science.gov (United States)

    Tawde, Pooja; Dabadghav, Rachana; Bedekar, Nilima; Shyam, Ashok; Sancheti, Parag

    2016-12-01

    Playing the violin can lead to asymmetric postures which can affect the cervical range of motion, cervical core strength and scapular stability. The objective of the study was to assess the cervical range of motion, cervical core strength and scapular dyskinesia in violin players and non-players of the same age group. An inclinometer was used to assess the cervical range of motion, pressure biofeedback was used to assess cervical core strength and scapular dyskinesia was also assessed in 30 professional violin players (18-40 years) compared with 30 age-matched non-players. Analysis was done using an unpaired t test. Significant change was seen with respect to extension (p = 0.051), cervical core strength (p = 0.005), right (Rt) superior angle 0° (p = 0.004), Rt superior angle 45° (p = 0.015) and Rt inferior angle 90° (p = 0.013). This study shows a significant difference in extension range of motion and cervical core strength of violin players. Also, there was scapular dyskinesia seen at 0° and 45° right-side superior angle of the scapula and 90° right-side inferior angle of the scapula.

  19. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  20. Scaling laws for mode lockings in circle maps

    International Nuclear Information System (INIS)

    Cvitanovic, P.; Shraiman, B.; Soederberg, B.

    1985-06-01

    The self-similar structure of mode lockings for circle maps is studied by means of the associated Farey trees. We investigate numerically several classes of scaling relations implicit in the Farey organization of mode lockings and discuss the extent to which they lead to universal scaling laws. (orig.)

  1. Cervical precancerous changes and selected cervical microbial infections, Kiambu County, Kenya, 2014: a cross sectional study.

    Science.gov (United States)

    Kanyina, Evalyne Wambui; Kamau, Lucy; Muturi, Margaret

    2017-09-25

    Cervical cancer is the predominant cancer among women in Kenya and second most common in women in developing regions. Population-based cytological screening and early treatment reduces morbidity and mortality associated with the cancer. We determined the occurrence of cervical precancerous changes and cervical microbial infections (Trichomonas vaginalis, Candida albicans, Neisseria gonorrhea and Actinomyces) among women attending Family Health Option Kenya (FHOK) clinic in Thika. This was a hospital based cross sectional study among women attending reproductive health screening clinic from November 2013 to January 2014. Cervical Intraepithelial Neoplasia (CIN) I, II, III, cervical cancer and microbial infection (Actinomyces, Trichomonas vaginalis and Yeast cells) diagnosis was based on Pap smear screening test and High Vaginal Swab wet preparation microscopy. Neisseria gonorrhea was diagnosed through Gram staining. Socio-demographic and reproductive health data was collected using a structured questionnaire administered to the study participants and analyzed using Epi Info version 3.5.1. Of the 244 women screened, 238 (97.5%) presented with cervical inflammation, 80 (32.8%) cervical microbial infections and 12 (4.9%) cervical precancerous changes; 10 (83.3%) with CIN I and 2 (16.7%) CIN II. Of the 80 cervical microbial infections, 62 (77.5%) were yeast cell and 18 (22.5%) T. vaginalis. One thirty four (55%) participants had no history of Pap smear screening of which 84 (62.7%) were 20-40 years. Use of IUCDs (OR: 2.47, 95% CI 1.3-4.6) was associated with cervical inflammation. CIN I was the predominant cervical precancerous change. There is need to scale up cervical screening test to capture all categories of women.

  2. Navigation Study of Lower Lock Approach, John Day Lock and Dam, Columbia River, Oregon

    National Research Council Canada - National Science Library

    Wilson, Donald

    2001-01-01

    Representatives of the Columbia River Towing Association reported recent structural and/or operational changes at John Day Lock and Dam have created difficult navigation conditions for tows entering...

  3. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2014-11-01

    Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

  4. Loading effects of anterior cervical spine fusion on adjacent segments

    Directory of Open Access Journals (Sweden)

    Chien-Shiung Wang

    2012-11-01

    Full Text Available Adjacent segment degeneration typically follows anterior cervical spine fusion. However, the primary cause of adjacent segment degeneration remains unknown. Therefore, in order to identify the loading effects that cause adjacent segment degeneration, this study examined the loading effects to superior segments adjacent to fused bone following anterior cervical spine fusion. The C3–C6 cervical spine segments of 12 sheep were examined. Specimens were divided into the following groups: intact spine (group 1; and C5–C6 segments that were fused via cage-instrumented plate fixation (group 2. Specimens were cycled between 20° flexion and 15° extension with a displacement control of 1°/second. The tested parameters included the range of motion (ROM of each segment, torque and strain on both the body and inferior articular process at the superior segments (C3–C4 adjacent to the fused bone, and the position of the neutral axis of stress at under 20° flexion and 15° extension. Under flexion and Group 2, torque, ROM, and strain on both the bodies and facets of superior segments adjacent to the fused bone were higher than those of Group 1. Under extension and Group 2, ROM for the fused segment was less than that of Group 1; torque, ROM, and stress on both the bodies and facets of superior segments adjacent to the fused bone were higher than those of Group 1. These analytical results indicate that the muscles and ligaments require greater force to achieve cervical motion than the intact spine following anterior cervical spine fusion. In addition, ROM and stress on the bodies and facets of the joint segments adjacent to the fused bone were significantly increased. Under flexion, the neutral axis of the stress on the adjacent segment moved backward, and the stress on the bodies of the segments adjacent to the fused bone increased. These comparative results indicate that increased stress on the adjacent segments is caused by stress-shielding effects

  5. John Locke and the right to resistance

    Directory of Open Access Journals (Sweden)

    Jovanov Ilija D.

    2015-01-01

    Full Text Available John Locke was a great thinker and many works have been devoted to clear up his theories. One of the most significant, stated in his principal work, Two Treatises of Government, is the theory of the right to resistance. It was a bit revolutionary then, and to a large extent it is today. Domination of legal positivism is negation of that, by Locke, natural right. However, the fact is that in recent times the resistance to the established power occurs in a number of countries and in different forms, so that the idea of the right to resistance becomes live question again. In this regard it is interesting to consider Locke's viewpoint on this important issue and to determine whether his theory on the resistance is applicable in modern societies.

  6. Surgical Management of Subaxial Cervical Spine Trauma: A Case Report

    Directory of Open Access Journals (Sweden)

    Hasan Emre Aydın

    2015-04-01

    Full Text Available These days, as a consequence of the improvement in technology and increase in the use of motor vehicles, spine injuries have become common. Spine traumas, which often occur after motor vehicle accidents, are observed mostly in cervical regions, particularly in the subaxial cervical region, which is also known as the subcervical region, and neurological damage occurs in 70% of the patients. Despite still being controversial, the common ranging for neurological evaluation is the American Spinal Injury Association ranging, which includes the motor and sensory loss and accordingly, the impairment rate. In subaxial cervical traumas, acute neurological deterioration is an indication and therefore requires urgent surgical treatment. The choice of anterior or posterior approach substantially depends on the traumatization mechanism, affected tissues, and neurological deterioration occurring after. The state of patient and instability are the most two important factors affecting the treatment decision. Although the anterior approach is accepted as a routinely available and easily applicable surgical technique, it lacks in the burst fractures involving the three colons, which shows a stabilization disorder. The anterior plate screw technique and posterior lateral mass screw application applied in our clinic are reviewed in literature and are discussed in two cases. Although the best clinical results are achieved in cases where only anterior surgery is performed and in cases where instability is excessive, in unstable compression and blow-out fractures, even if neurological deficit and three colon involvement are not observed in the patient, the requirement of posterior fusion is observed.

  7. Cervical Vertigo: Historical Reviews and Advances.

    Science.gov (United States)

    Peng, Baogan

    2018-01-01

    Vertigo is one of the most common presentations in adult patients. Among the various causes of vertigo, so-called cervical vertigo is still a controversial entity. Cervical vertigo was first thought to be due to abnormal input from cervical sympathetic nerves based on the work of Barré and Liéou in 1928. Later studies found that cerebral blood flow is not influenced by sympathetic stimulation. Ryan and Cope in 1955 proposed that abnormal sensory information from the damaged joint receptors of upper cervical regions may be related to pathologies of vertigo of cervical origin. Further studies found that cervical vertigo seems to originate from diseased cervical intervertebral discs. Recent research found that the ingrowth of a large number of Ruffini corpuscles into diseased cervical discs may be related to vertigo of cervical origin. Abnormal neck proprioceptive input integrated from the signals of Ruffini corpuscles in diseased cervical discs and muscle spindles in tense neck muscles secondary to neck pain is transmitted to the central nervous system and leads to a sensory mismatch with vestibular and other sensory information, resulting in a subjective feeling of vertigo and unsteadiness. Further studies are needed to illustrate the complex pathophysiologic mechanisms of cervical vertigo and to better understand and manage this perplexing entity. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Control of photon storage time using phase locking.

    Science.gov (United States)

    Ham, Byoung S

    2010-01-18

    A photon echo storage-time extension protocol is presented by using a phase locking method in a three-level backward propagation scheme, where phase locking serves as a conditional stopper of the rephasing process in conventional two-pulse photon echoes. The backward propagation scheme solves the critical problems of extremely low retrieval efficiency and pi rephasing pulse-caused spontaneous emission noise in photon echo based quantum memories. The physics of the storage time extension lies in the imminent population transfer from the excited state to an auxiliary spin state by a phase locking control pulse. We numerically demonstrate that the storage time is lengthened by spin dephasing time.

  9. Prospective, randomized multicenter study of cervical arthroplasty versus anterior cervical discectomy and fusion: 5-year results with a metal-on-metal artificial disc.

    Science.gov (United States)

    Coric, Domagoj; Guyer, Richard D; Nunley, Pierce D; Musante, David; Carmody, Cameron; Gordon, Charles; Lauryssen, Carl; Boltes, Margaret O; Ohnmeiss, Donna D

    2018-03-01

    OBJECTIVE Seven cervical total disc replacement (TDR) devices have received FDA approval since 2006. These devices represent a heterogeneous assortment of implants made from various biomaterials with different biomechanical properties. The majority of these devices are composed of metallic endplates with a polymer core. In this prospective, randomized multicenter study, the authors evaluate the safety and efficacy of a metal-on-metal (MoM) TDR (Kineflex|C) versus anterior cervical discectomy and fusion (ACDF) in the treatment of single-level spondylosis with radiculopathy through a long-term (5-year) follow-up. METHODS An FDA-regulated investigational device exemption (IDE) pivotal trial was conducted at 21 centers across the United States. Standard validated outcome measures including the Neck Disability Index (NDI) and visual analog scale (VAS) for assessing pain were used. Patients were randomized to undergo TDR using the Kineflex|C cervical artificial disc or anterior cervical fusion using structural allograft and an anterior plate. Patients were evaluated preoperatively and at 6 weeks and 3, 6, 12, 24, 36, 48, and 60 months after surgery. Serum ion analysis was performed on a subset of patients randomized to receive the MoM TDR. RESULTS A total of 269 patients were enrolled and randomly assigned to undergo either TDR (136 patients) or ACDF (133 patients). There were no significant differences between the TDR and ACDF groups in terms of operative time, blood loss, or length of hospital stay. In both groups, the mean NDI scores improved significantly by 6 weeks after surgery and remained significantly improved throughout the 60-month follow-up (both p < 0.01). Similarly, VAS pain scores improved significantly by 6 weeks and remained significantly improved through the 60-month follow-up (both p < 0.01). There were no significant changes in outcomes between the 24- and 60-month follow-ups in either group. Range of motion in the TDR group decreased at 3 months but

  10. Control of integrated micro-resonator wavelength via balanced homodyne locking.

    Science.gov (United States)

    Cox, Jonathan A; Lentine, Anthony L; Trotter, Douglas C; Starbuck, Andrew L

    2014-05-05

    We describe and experimentally demonstrate a method for active control of resonant modulators and filters in an integrated photonics platform. Variations in resonance frequency due to manufacturing processes and thermal fluctuations are corrected by way of balanced homodyne locking. The method is compact, insensitive to intensity fluctuations, minimally disturbs the micro-resonator, and does not require an arbitrary reference to lock. We demonstrate long-term stable locking of an integrated filter to a laser swept over 1.25 THz. In addition, we show locking of a modulator with low bit error rate while the chip temperature is varied from 5 to 60° C.

  11. Effect of ship locking on sediment oxygen uptake in impounded rivers

    DEFF Research Database (Denmark)

    Lorke, A.; McGinnis, D. F.; Maeck, A.

    2012-01-01

    In the majority of large river systems, flow is regulated and/or otherwise affected by operational and management activities, such as ship locking. The effect of lock operation on sediment-water oxygen fluxes was studied within a 12.9 km long impoundment at the Saar River (Germany) using eddy....... Additional means by which the oxygen budget of the impoundment is affected by lock-induced flow variations are discussed. Citation: Lorke, A., D. F. McGinnis, A. Maeck, and H. Fischer (2012), Effect of ship locking on sediment oxygen uptake in impounded rivers, Water Resour. Res., 48, W12514, doi: 10....... These wave-induced flow variations cause variations in sediment-water oxygen fluxes. While the mean flux during time periods without lock operation was 0.5 +/- 0.1 g m(-2) d(-1), it increased by about a factor of 2 to 1.0 +/- 0.5 g m(-2) d(-1) within time periods with ship locking. Following the daily...

  12. Tuina treatment in cervical spondylosis

    Directory of Open Access Journals (Sweden)

    Florin Mihai Hinoveanu

    2010-12-01

    Full Text Available Cervical spondylosis is a common, chronic degenerative condition of the cervical spine that affects the vertebral bodies and intervertebral disks of the neck as well as the contents of the spinal canal. Common clinical syndromes associated with cervical spondylosis include cervical pain, cervical radiculopathy and/or mielopathy. This study show the main principles, indication and side effects of tuina in cervical spondylosis´ treatment; tuina is one of the external methods based on the principles of Traditional Chinese Medicine (TCM, especially suitable for use on the elderly population and on infants. While performing Tuina, the therapist concentrates his mind, regulates his breathing, and actuates the Qi and power of his entire body towards his hands. For a better result is recommended to try to combine acupuncture with tuina treatment. Tuina can help relieve the pain associated with spondylosis. After this kind of treatment, the symptomes produced by irritated nerves and sore muscles can find some relief. Tuina helps patients with cervical spondylosis regain muscle control, nerve function and flexibility, all through the restoration of the life force flow.

  13. Assembly mechanism for nuclear fuel bundles

    International Nuclear Information System (INIS)

    Long, J.W.; Flora, B.S.

    1977-01-01

    A method of securing a fuel bundle to permit easy remote disassembly is described. Fuel rods are held loosely between end plates, each end of the rods fitting into holes in the end plates. At the upper end of each fuel rod there is a spring pressing against the end plate. Tie rods are used to hold the end plates together securely. The lower end of each tie rod is screwed into the lower end plate; the upper end of each tie rod is attached to the upper end plate by means of a locking assembly described in the patent. In order to remove the upper tie plate during the disassembly process, it is necessary only to depress the tie plate against the pressure of the springs surrounding the fuel rods and then to rotate each locking sleeve on the tie rods from its locked to its unlocked position. It is then possible to remove the tie plate without disassembling the locking assembly. (LL)

  14. 49 CFR 236.335 - Dogs, stops and trunnions of mechanical locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Dogs, stops and trunnions of mechanical locking..., AND APPLIANCES Interlocking Rules and Instructions § 236.335 Dogs, stops and trunnions of mechanical locking. Driving pieces, dogs, stops and trunnions shall be rigidly secured to locking bars. Swing dogs...

  15. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock on hand-operated switch; control...

  16. Aktuaalsetest tendentsidest elektroakustilise muusika alal Eestis / Gerhard Lock

    Index Scriptorium Estoniae

    Lock, Gerhard, 1978-

    2007-01-01

    Elektroakustilise muusika lähiajaloost, elektroakustilist muusikat viljelevatest Eesti heliloojatest. Age Hirv, Raun Juurikas, Liis Jürgens, Andrus Kallastu, Tatjana Kozlova, Ülo Krigul, Margo Kõlar, Märt-Matis Lill, Gerhard Lock, Hans-Gunter Lock, Malle Maltis, Jüri Reinvere, Mart Siimer, Mirjam Tally, Toomas Trass, Lauri-Dag Tüür oma muusikast

  17. Thyroid storm following anterior cervical spine surgery for tuberculosis of cervical spine

    Directory of Open Access Journals (Sweden)

    Sanjiv Huzurbazar

    2014-01-01

    Full Text Available Objective: The primary objective was to report this rare case and discuss the probable mechanism of thyroid storm following anterior cervical spine surgery for Kochs cervical spine.

  18. The polymethyl methacrylate cervical cage for treatment of cervical disk disease Part III. Biomechanical properties.

    Science.gov (United States)

    Chen, Jyi-Feng; Lee, Shih-Tseng

    2006-10-01

    In a previous article, we used the PMMA cervical cage in the treatment of single-level cervical disk disease and the preliminary clinical results were satisfactory. However, the mechanical properties of the PMMA cage were not clear. Therefore, we designed a comparative in vitro biomechanical study to determine the mechanical properties of the PMMA cage. The PMMA cervical cage and the Solis PEEK cervical cage were compressed in a materials testing machine to determine the mechanical properties. The compressive yield strength of the PMMA cage (7030 +/- 637 N) was less than that of the Solis polymer cervical cage (8100 +/- 572 N). The ultimate compressive strength of the PMMA cage (8160 +/- 724 N) was less than that of the Solis cage (9100 +/- 634 N). The stiffness of the PMMA cervical cage (8106 +/- 817 N/mm) was greater than that of the Solis cage (6486 +/- 530 N/mm). The elastic modulus of the PMMA cage (623 +/- 57 MPa) was greater than that of the Solis cage (510 +/- 42 MPa). The elongation of PMMA cage (43.5 +/- 5.7%) was larger than that of the Solis cage (36.1 +/- 4.3%). Although the compressive yield strength and ultimate compressive strength of the PMMA cervical cage were less than those of the Solis polymer cage, the mechanical properties are better than those of the cervical vertebral body. The PMMA cage is strong and safe for use as a spacer for cervical interbody fusion. Compared with other cage materials, the PMMA cage has many advantages and no obvious failings at present. However, the PMMA cervical cage warrants further long-term clinical study.

  19. Human papillomavirus infection among Bangladeshi women with cervical intraepithelial neoplasia and chronic cervicitis

    Directory of Open Access Journals (Sweden)

    Elisha Khandker

    2016-01-01

    Full Text Available Background and objectives: Cervical cancer is one of the leading causes of morbidity and mortality. Human papillomavirus (HPV is known to be associated with cervical intraepithelial neoplasia (CIN and cancer. The objective of the present study was to determine the rate of HPV infection among the Bangladeshi women with different grades of CIN and cancer. Methods: Women aged 20 to 55 years, diagnosed as a case of chronic cervicits, cervical intraepithelial neoplasia (CIN or invasive cancer by Papanicolaou (Pap smear and colposcopy directed biopsy were enrolled in the study. High and intermediate risk oncogenic HPV were detected in cervical samples by real time PCR (rt-PCR. Results: Seventy two women with chronic cervicitis and different grades of CIN were included in the study. Out of 72 cases, 28 (38.9% and 44 (61.1% had chronic cervicitis and CIN respectively. Overall, the HPV infection rate was 43.1% (95% CI= 32%-54% among the study population. CIN cases had significantly high (p<0.01 HPV infection (78.6%; 95% CI=60%-89% compared to cases with chronic cervicitis (18.2%; 95% CI=11.1%-34.5%. Women between the age of 20-30 years had the highest positive rate (50.0% followed by 31-40 years age group (43.6%. All CIN grade 2 and 3 had HPV infection. Conclusion: The study showed that HPV was strongly associated with different grades of CIN. Specific HPV types should be determined to find out the most prevalent HPV types among the Bangladeshi women with CIN and cervical cancers. IMC J Med Sci 2016; 10(1: 29-32

  20. Tom Bevill Upper Lock Approach, Tennessee-Tombigbee Waterway, Alabama: Hydraulic Navigation Investigation

    National Research Council Canada - National Science Library

    Winkler, Michael

    2003-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  1. Percutaneous endoscopic cervical discectomy for discogenic cervical headache due to soft disc herniation

    International Nuclear Information System (INIS)

    Ahn, Y.; Lee, S.H.; Shin, S.W.; Chung, S.E.; Park, H.S.

    2005-01-01

    A discogenic cervical headache is a subtype of cervicogenic headache (CEH) that arises from a degenerative cervical disc abnormality. The purpose of this study was to evaluate the clinical outcome of percutaneous endoscopic cervical discectomy (PECD) for patients with chronic cervical headache due to soft cervical disc herniation. Seventeen patients underwent PECD for intractable headache. The inclusion criteria were soft disc herniation without segmental instability, proven by both local anesthesia and provocative discography for headache unresponsive to conservative treatment. The mean follow-up period was 37.6 months. Fifteen of the 17 patients (88.2%) showed successful outcomes based on the Macnab criteria. Pain scores on a visual analog scale (VAS) improved from a preoperative mean of 8.35±0.79 to 2.12±1.17, postoperatively (P<0.01). The mean disc height decreased from 6.81±1.08 to 5.98±1.07 mm (P<0.01). There was no newly developed segmental instability or spontaneous fusion on follow-up radiography. In conclusion, PECD appears to be effective for chronic severe discogenic cervical headache under strict inclusion criteria. (orig.)

  2. Door locking and exit security measures on acute psychiatric admission wards

    NARCIS (Netherlands)

    Nijman, H.L.I.; Bowers, L.; Haglund, K.; Muir-Cochrane, E.; Simpson, A.; Merwe, M. van der

    2011-01-01

    Locking the exit doors of psychiatric wards is believed to reduce the risk of patients absconding. The aims of the study were to investigate both the prevalence of door locking and other exit security measures on UK admission wards, as well as whether door locking appears to be effective in keeping

  3. Experimental evaluation of the stability of goat's cervical spine after percutaneous cervical diskectomy

    International Nuclear Information System (INIS)

    Du Zhongli; Zhou Yicheng; Wang Chengyuan; Hong Cheng; Liu Hanqiao; Zhang Jiangfan; Ding Hui; Feng Dingyi

    1999-01-01

    Objective: To evaluate the stability of the goat's cervical spine after PCD (percutaneous cervical diskectomy). Methods: Ten adult goats were studied. Seven had PCD at C 3-4 , and three at C 4-5 . The cervical spine of the goat was studied with MR using axial, corona land sagittal images and with anteroposterior and lateral radiographs before and after PCD. The height of the disk, the disk space angle and dislocation were measured respectively before and after PCD. The data were examined by t-test. Results: The disk space (7 cases, 70%) became narrow obviously, and hyperostosis (5 cases, 50%) disk bulging (4 cases, 40%) appeared after PCD, but there was no obvious dislocation or angulation between the adjacent vertebral bodies. Conclusions: The stability of the goat's cervical spine is not affected after PCD. Indicating that this might also hold true for human cervical spine

  4. Cervical Cancer—Health Professional Version

    Science.gov (United States)

    The primary risk factor for cervical cancer is human papillomavirus (HPV) infection. Most cases of cervical cancer are preventable by routine screening and by treatment of precancerous lesions. Find evidence-based information on cervical cancer treatment, causes and prevention, screening, research, and statistics.

  5. Advances phase-lock techniques

    CERN Document Server

    Crawford, James A

    2008-01-01

    From cellphones to micrprocessors, to GPS navigation, phase-lock techniques are utilized in most all modern electronic devices. This high-level book takes a systems-level perspective, rather than circuit-level, which differentiates it from other books in the field.

  6. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  7. A scalable lock-free hash table with open addressing

    DEFF Research Database (Denmark)

    Nielsen, Jesper Puge; Karlsson, Sven

    2016-01-01

    and concurrent operations without any locks. In this paper, we present a new fully lock-free open addressed hash table with a simpler design than prior published work. We split hash table insertions into two atomic phases: first inserting a value ignoring other concurrent operations, then in the second phase......Concurrent data structures synchronized with locks do not scale well with the number of threads. As more scalable alternatives, concurrent data structures and algorithms based on widely available, however advanced, atomic operations have been proposed. These data structures allow for correct...

  8. Cervical lung hernia

    Science.gov (United States)

    Lightwood, Robin G.; Cleland, W. P.

    1974-01-01

    Lightwood, R. G., and Cleland, W. P. (1974).Thorax, 29, 349-351. Cervical lung hernia. Lung hernias occur in the cervical position in about one third of cases. The remainder appear through the chest wall. Some lung hernias are congenital, but trauma is the most common cause. The indications for surgery depend upon the severity of symptoms. Repair by direct suture can be used for small tears in Sibson's (costovertebral) fascia while larger defects have been closed using prosthetic materials. Four patients with cervical lung hernia are described together with an account of their operations. PMID:4850946

  9. THE CERVICAL CANCER SCREENING - UNSOLVED PROBLEMS

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available The problem of cervical cancer (CC for many decades continues to be the center of attention leading foreign and domestic oncologists. Malignant cervical tumors occupy the leading position among malignant neoplasms of reproductive system in women, second only to breast cancer, despite having far more effective screening compared with this disease. On predictive expert estimates (taking into account population growth and the expected increase in life expectancy by 2020 in developing countries, the rising incidence and prevalence of cervical cancer is 40%, while in developed countries - 11%. If we do not perform timely interventions for prevention and treatment of cervical cancer, after 2050 cervical cancer every year in the world will become sick 1 million women. In the last decade inRussiathere has been a gradual increase in the incidence of cervical cancer: average annual growth rate of 2.21%, General 25,18%. Cervical cancer is one of nosological forms that meet all the requirements of population-based screening. The current Russian normative documents do not give clear answers to questions concerning the age of onset of cervical cancer screening and the time interval between tests, no clear program organized cytological screening of cervical cancer.

  10. Impact of Fat Infiltration in Cervical Extensor Muscles on Cervical Lordosis and Neck Pain: A Cross-Sectional Study.

    Science.gov (United States)

    Kim, Choong-Young; Lee, Sang-Min; Lim, Seong-An; Choi, Yong-Soo

    2018-06-01

    Weakness of cervical extensor muscles causes loss of cervical lordosis, which could also cause neck pain. The aim of this study was to investigate the impact of fat infiltration in cervical extensor muscles on cervical lordosis and neck pain. Fifty-six patients who suffered from neck pain were included in this study. Fat infiltration in cervical extensor muscles was measured at each level of C2-3 and C6-7 using axial magnetic resonance imaging. The visual analogue scale (VAS), 12-Item Short Form Health Survey (SF-12), and Neck Disability Index (NDI) were used for clinical assessment. The mean fat infiltration was 206.3 mm 2 (20.3%) at C2-3 and 240.6 mm 2 (19.5%) at C6-7. Fat infiltration in cervical extensor muscles was associated with high VAS scores at both levels ( p = 0.047 at C2-3; p = 0.009 at C6-7). At C2-3, there was a negative correlation between fat infiltration of the cervical extensor muscles and cervical lordosis (r = -0.216; p = 0.020). At C6-7, fat infiltration in the cervical extensor muscles was closely related to NDI ( p = 0.003) and SF-12 ( p > 0.05). However, there was no significant correlation between cervical lordosis and clinical outcomes (VAS, p = 0.112; NDI, p = 0.087; and SF-12, p > 0.05). These results suggest that fat infiltration in the upper cervical extensor muscles has relevance to the loss of cervical lordosis, whereas fat infiltration in the lower cervical extensor muscles is associated with cervical functional disability.

  11. Experimental investigation of different regimes of mode-locking in a high repetition rate passively mode-locked semiconductor quantum-dot laser.

    Science.gov (United States)

    Kéfélian, Fabien; O'Donoghue, Shane; Todaro, Maria Teresa; McInerney, John; Huyet, Guillaume

    2009-04-13

    We report experimental investigations on a two-section 16-GHz repetition rate InAs/GaAs quantum dot passively mode-locked laser. Near the threshold current, pseudo-periodic Q-switching with complex dynamics is exhibited. Mode-locking operation regimes characterized by different repetition rates and timing jitter levels are encountered up to twice the threshold current. Evolution of the RF spectrum and optical spectrum with current is compared. The different mode-locked regimes are shown to be associated with different spectral and temporal shapes, ranging from 1.3 to 6 ps. This point is discussed by introducing the existence of two different supermodes. Repetition rate evolution and timing jitter increase is attributed to the coupling between the dominant and the secondary supermodes.

  12. Titanium/Polyetheretherketone Cages for Cervical Arthrodesis with Degenerative and Traumatic Pathologies: Early Clinical Outcomes and Fusion Rates.

    Science.gov (United States)

    Chong, Elizabeth; Mobbs, Ralph J; Pelletier, Matthew H; Walsh, William R

    2016-02-01

    Anterior cervical discectomy and fusion is the most commonly employed surgical technique for treating cervical spondylosis. Although autologous bone grafts are considered the gold standard in achieving fusion, associated short- and long-term morbidities have led to a search for alternative materials. These have included carbon-fiber, titanium alloy (Ti) and ceramic and polyetheretherketone (PEEK) based implants. Recent attempts to optimize cage implants through using composite designs have combined Ti and PEEK. However, there are few published reports on the clinical and radiological outcomes of commercially available composite cages. Our study aimed to provide and evaluate initial outcomes of a composite Ti/PEEK cage. In this prospective single senior surgeon cohort study, 31 consecutive patients underwent a modified Smith-Robinson technique under general anesthesia and relevant data were collected. The study patients were aged between 18 and 75 years and underwent surgery from November 2013 to May 2014. Indications for surgery included traumatic and degenerative cervical disease that was unsuitable for or unresponsive to conservative management. All cages were between 5 and 8 mm and packed with super critical fluid sterilized allograft and bone marrow aspirate before insertion. Patients were followed-up for a minimum of 12 months. Fusion was assessed using fine cut CT and anteroposterior and lateral radiographs. Clinical outcomes were measured using a Visual Analogue Scale, Neck Oswestry Disability Index and Patient's Satisfaction Index. Six of the original cohort were unavailable for adequate follow-up. The remaining 25 patients (17 men, 8 women; 33 operative levels) were observed for a mean of 14.6 months (range, 12-16 months). All operation levels were between C4 and C7 . Single-level operations were performed in 19 patients and additional plating in 14 patients. A fusion rate of 96% was achieved. Patients in both plated and non-plated groups experienced

  13. Space-time considerations in the phase locking of high harmonics

    International Nuclear Information System (INIS)

    Gaarde, Mette B.; Schafer, Kenneth J.

    2002-01-01

    The combination of several high order harmonics can produce an attosecond pulse train, provided that the harmonics are locked in phase to each other. We present calculations that evaluate the degree of phase locking that is achieved in argon and neon gases interacting with an intense, 50 fs laser pulse, for a range of macroscopic conditions. We find that phase locking depends on both the temporal and the spatial phase behavior of the harmonics, as determined by the interplay between the intrinsic dipole phase and the phase matching in the nonlinear medium. We show that, as a consequence of this, it is not possible to compensate for a lack of phase locking by purely temporal phase manipulation

  14. Phase locking of moving magnetic vortices in bridge-coupled nanodisks

    International Nuclear Information System (INIS)

    Zhu, Qiyuan; Zheng, Qi; Liu, Xianyin; Liu, Qingfang; Wang, Jianbo

    2015-01-01

    In this paper, phase locking dynamics of vortices induced by spin transfer torque in bridge-coupled nanodisks are studied by micromagnetic simulations. In the presence of the bridge coupling, the required time for the phase locking is dramatically reduced, and the phase difference between the two vortices keeps at a nonzero value after the phase locking. Moreover, the phase difference is affected significantly by bridge coupling, Oersted field distribution, nanodisk size, as well as in-plane bias magnetic field. In addition, the coupled gyrotropic frequency of vortices depends linearly on the perpendicular magnetic field. This systematic study of phase locking parameters, especially the phase difference, is important for the applications of vortex-based spin-torque nano-oscillators

  15. Phase locking of moving magnetic vortices in bridge-coupled nanodisks

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Qiyuan; Zheng, Qi; Liu, Xianyin; Liu, Qingfang, E-mail: liuqf@lzu.edu.cn [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Wang, Jianbo [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Key Laboratory of Special Function Materials and Structure Design, Ministry of Education, Lanzhou University, Lanzhou 730000 (China)

    2015-05-07

    In this paper, phase locking dynamics of vortices induced by spin transfer torque in bridge-coupled nanodisks are studied by micromagnetic simulations. In the presence of the bridge coupling, the required time for the phase locking is dramatically reduced, and the phase difference between the two vortices keeps at a nonzero value after the phase locking. Moreover, the phase difference is affected significantly by bridge coupling, Oersted field distribution, nanodisk size, as well as in-plane bias magnetic field. In addition, the coupled gyrotropic frequency of vortices depends linearly on the perpendicular magnetic field. This systematic study of phase locking parameters, especially the phase difference, is important for the applications of vortex-based spin-torque nano-oscillators.

  16. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  17. Evaluation of arthrodesis and cervical alignment in the surgical results of cervical discectomy using polymethylmetacrylate Avaliação da artrodese e do alinhamento cervical após discectomia cervical com interposição de polimetilmetacrilato

    Directory of Open Access Journals (Sweden)

    Marcelo Luis Mudo

    2009-09-01

    Full Text Available BACKGROUND AND OBJECTIVES: Surgical treatment of cervical radiculopathy with or without myelopathy is a controversy issue, although anterior discectomy is the most common form of treatment. METHOD: We present the evaluation of the arthrodesis' rate and cervical alignment in 48 patients with cervical degenerative disease (CDD submitted to anterior cervical discectomy with interposition of polymethylmetacrylate (PMMA. Odom and Nürick scales were used to evaluation of functional status before and after surgery. Cervical spine X-rays were used to access arthrodesis and alignment, at least 2 years after the procedure. RESULTS: Excellent and good results (Odom I and II were obtained in 91% of the patients with radiculopathy and in 69% of those with myelopathy. Using the chi square test of independence (1% of significance, there was no association between excellent and good clinical results with the presence of arthrodesis verified in cervical X-rays. The presence of cervical alignment had association with good results, whereas the misalignment was associated with unfavorable outcomes. Two patients died: one cervical hematoma and other from graft migration with cord compression. CONCLUSIONS: Cervical alignment was more important than fusion to achieve good surgical results in CDD.TEMA E OBJETIVO: O tratamento cirúrgico da radiculopatia cervical com ou sem mielopatia é um tema controverso, embora a discectomia por via anterior seja uma das formas mais comuns de tratamento. MÉTODO: Apresentamos a avaliação da artrodese cervical e do alinhamento pós operatório em 48 pacientes com doença degenerativa cervical (DDC submetidos a discectomia por via anterior seguida da interposição de polimetilmetacrilato (PMMA. As escalas de Odom e de Nurick foram utilizadas para avaliar o status funcional dos pacientes antes e após a cirurgia. Radiografias da coluna cervical foram utilizadas para avaliar a artrodese e o alinhamento cervical, pelo menos 2 anos ap

  18. Mutual phase-locking of several spin-torque nano-oscillators

    International Nuclear Information System (INIS)

    Prokopenko, O.V.; Sulimenko, O.R.

    2011-01-01

    Criterions for evaluating the effectiveness of mutual phase-locking of several spin-torque nano-oscillators (STNO) are proposed. An application of one of the criterions to describe the process of mutual phase-locking of the three almost identical STNO's is considered

  19. Incidence of cervical dysplasia and cervical cancer in women living with HIV in Denmark

    DEFF Research Database (Denmark)

    Thorsteinsson, Kristina; Ladelund, Steen; Jensen-Fangel, Søren

    2014-01-01

    and hazard ratios (HRs) for time from inclusion to first cervical intraepithelial neoplasia (CIN)/ICC and time from first normal cervical cytology to first CIN/ICC were estimated. Sensitivity analyses were performed to include prior screening outcome, screening intensity and treatment of CIN......INTRODUCTION: Women living with HIV (WLWH) are reportedly at increased risk of invasive cervical cancer (ICC). WLWH in Denmark attend the National ICC screening program less often than women in the general population. We aimed to estimate the incidence of cervical dysplasia and ICC in WLWH...... with normal baseline cytology, incidences of CIN1+ and CIN2+ were higher in WLWH. However, incidences were comparable between WLWH and controls adherent to the National ICC screening program. CONCLUSIONS: Overall, WLWH develop more cervical disease than controls. However, incidences of CIN are comparable...

  20. Incidence of cervical dysplasia and cervical cancer in women living with HIV in Denmark

    DEFF Research Database (Denmark)

    Thorsteinsson, K; Ladelund, Steen; Jensen-Fangel, S

    2016-01-01

    , which contains nationwide records of all pathology specimens. The cumulative incidence and hazard ratios (HRs) for time from inclusion to first cervical intraepithelial neoplasia (CIN)/ICC and time from first normal cervical cytology result to first CIN/ICC were estimated. Sensitivity analyses were......OBJECTIVES: Women living with HIV (WLWH) are reportedly at increased risk of invasive cervical cancer (ICC). A recent publication found that WLWH in Denmark attend the national ICC screening programme less often than women in the general population. We aimed to estimate the incidence of cervical...... in both groups were adherent to the national ICC screening programme and had a normal baseline cytology, incidences of CIN and ICC were comparable. CONCLUSIONS: Overall, WLWH developed more cervical disease than controls. Yet, in WLWH and controls adherent to the national ICC screening programme...

  1. Relationship Between T1 Slope and Cervical Alignment Following Multilevel Posterior Cervical Fusion Surgery: Impact of T1 Slope Minus Cervical Lordosis.

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Ki-Jeong; Jahng, Tae-Ahn; Kim, Hyun-Jib

    2016-04-01

    Retrospective study. To assess the relationship between sagittal alignment of the cervical spine and patient-reported health-related quality-of-life scores following multilevel posterior cervical fusion, and to explore whether an analogous relationship exists in the cervical spine using T1 slope minus C2-C7 lordosis (T1S-CL). A recent study demonstrated that, similar to the thoracolumbar spine, the severity of disability increases with sagittal malalignment following cervical reconstruction surgery. From 2007 to 2013, 38 consecutive patients underwent multilevel posterior cervical fusion for cervical stenosis, myelopathy, and deformities. Radiographic measurements included C0-C2 lordosis, C2-C7 lordosis, C2-C7 sagittal vertical axis (SVA), T1 slope, and T1S-CL. Pearson correlation coefficients were calculated between pairs of radiographic measures and health-related quality-of-life. C2-C7 SVA positively correlated with neck disability index (NDI) scores (r = 0.495). C2-C7 lordosis (P = 0.001) and T1S-CL (P = 0.002) changes correlated with NDI score changes after surgery. For significant correlations between C2-C7 SVA and NDI scores, regression models predicted a threshold C2-C7 SVA value of 50 mm, beyond which correlations were most significant. The T1S-CL also correlated positively with C2-C7 SVA and NDI scores (r = 0.871 and r = 0.470, respectively). Results of the regression analysis indicated that a C2-C7 SVA value of 50 mm corresponded to a T1S-CL value of 26.1°. This study showed that disability of the neck increased with cervical sagittal malalignment following surgical reconstruction and a greater T1S-CL mismatch was associated with a greater degree of cervical malalignment. Specifically, a mismatch greater than 26.1° corresponded to positive cervical sagittal malalignment, defined as C2-C7 SVA greater than 50 mm. 3.

  2. Experimental study of self-balanced startup characteristics of density lock

    International Nuclear Information System (INIS)

    Gu Haifeng; Yan Changqi; Chen Wei

    2013-01-01

    With passive residual heat removal system which applies the density lock as background, combining the experimental study and theoretical analysis, researches on the operating characteristics and feasibility of self-balanced startup of density lock were made in this system. The results show that self-balanced startup can be divided into two stages: Warming up stage in which the valve is closed; self-balanced stage in which the valve is open. The two requisite conditions ensuring the closure of density lock can be realized respectively in these two stages, which ensure the separation of the passive residual heat removal system from the primary circuit system by the density lock. During the stage of warming up, with the help of special structure of the density lock, the position of the transition points of the heat transfer modes is controlled effectively, and the formation of interface between the cold and hot fluids is promoted. During the self-balanced stage, with the help of the characteristics of self-stability of the hydraulic balance, the motion of interface is controlled effectively, and the hydraulic balance is established automatically in the density lock. All of the results fully prove the feasibility of self-balanced startup. (authors)

  3. Cervical cytology and the diagnosis of cervical cancer in older women.

    Science.gov (United States)

    Landy, Rebecca; Castanon, Alejandra; Dudding, Nick; Lim, Anita Wey Wey; Hollingworth, Antony; Hamilton, Willie; Sasieni, Peter D

    2015-12-01

    Most non-screen-detected cervical cancers are advanced stage. We assess the potential for cytology to expedite diagnosis when used outside of routine call and recall screening for cervical cancer. Two cohorts of women with cytology that did not appear to have been taken as part of routine screening, nested within a census of cervical cytology, in England between April 2007 and March 2010 were studied: 93,322 women aged 40-69 at first cytology, and 14,668 women aged ≥70. The diagnostic performance of high grade cervical squamous intraepithelial lesion (HSIL) or worse cytology was estimated. We also estimated case-fatality from stage distribution in women aged ≥66 with and without cytology in the year prior to diagnosis. There were 259 cancers diagnosed in women aged 40-69 at first cytology, and 78 in women aged ≥70. The sensitivity of cytology ≥ HSIL for cancer was 89% and 83% respectively, and the number of women needed to test to identify one cancer was 404 (95% confidence interval [CI]: 355-462) and 226 (95% CI: 177-292) respectively. Women aged ≥66 with cytology within a year of diagnosis had earlier stage cancers than those without, corresponding to a 17-22% reduction in case fatality. Cervical cytology is an excellent identifier of cancer among women tested outside routine screening call and recall. Its use as a triage tool, for instance in women with vague gynaecological symptoms, could facilitate earlier stage diagnosis and reduce cervical cancer mortality. © The Author(s) 2015.

  4. The locking and unlocking thresholds for tearing modes in a cylindrical tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Wenlong [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhu, Ping, E-mail: pzhu@ustc.edu.cn [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2016-03-15

    The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of the RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.

  5. Phase-locking regimes of photonic crystal nanocavity laser arrays

    DEFF Research Database (Denmark)

    Skovgård, Troels Suhr; Kristensen, Philip Trøst; Mørk, Jesper

    2011-01-01

    -difference time-domain calculations, the typical coupling strength is extracted for realistic structures. Phase-locking regimes are identified, and their stability with respect to parameter variation is investigated. The results suggest that quantum well devices are not well suited for phase-locked nanocavity...

  6. Diode array pumped, non-linear mirror Q-switched and mode-locked

    Indian Academy of Sciences (India)

    A non-linear mirror consisting of a lithium triborate crystal and a dichroic output coupler are used to mode-lock (passively) an Nd : YVO4 laser, pumped by a diode laser array. The laser can operate both in cw mode-locked and simultaneously Q-switched and mode-locked (QML) regime. The peak power of the laser while ...

  7. Performance Characterization of Loctite (Registered Trademark) 242 and 271 Liquid Locking Compounds (LLCs) as a Secondary Locking Feature for International Space Station (ISS) Fasteners

    Science.gov (United States)

    Dube, Michael J.; Gamwell, Wayne R.

    2011-01-01

    Several International Space Station (ISS) hardware components use Loctite (and other polymer based liquid locking compounds (LLCs)) as a means of meeting the secondary (redundant) locking feature requirement for fasteners. The primary locking method is the fastener preload, with the application of the Loctite compound which when cured is intended to resist preload reduction. The reliability of these compounds has been questioned due to a number of failures during ground testing. The ISS Program Manager requested the NASA Engineering and Safety Center (NESC) to characterize and quantify sensitivities of Loctite being used as a secondary locking feature. The findings and recommendations provided in this investigation apply to the anaerobic LLCs Loctite 242 and 271. No other anaerobic LLCs were evaluated for this investigation. This document contains the findings and recommendations of the NESC investigation

  8. Pathogenesis, Diagnosis, and Treatment of Cervical Vertigo.

    Science.gov (United States)

    Li, Yongchao; Peng, Baogan

    2015-01-01

    Cervical vertigo is characterized by vertigo from the cervical spine. However, whether cervical vertigo is an independent entity still remains controversial. In this narrative review, we outline the basic science and clinical evidence for cervical vertigo according to the current literature. So far, there are 4 different hypotheses explaining the vertigo of a cervical origin, including proprioceptive cervical vertigo, Barré-Lieou syndrome, rotational vertebral artery vertigo, and migraine-associated cervicogenic vertigo. Proprioceptive cervical vertigo and rotational vertebral artery vertigo have survived with time. Barré-Lieou syndrome once was discredited, but it has been resurrected recently by increased scientific evidence. Diagnosis depends mostly on patients' subjective feelings, lacking positive signs, specific laboratory examinations and clinical trials, and often relies on limited clinical experiences of clinicians. Neurological, vestibular, and psychosomatic disorders must first be excluded before the dizziness and unsteadiness in cervical pain syndromes can be attributed to a cervical origin. Treatment for cervical vertigo is challenging. Manual therapy is recommended for treatment of proprioceptive cervical vertigo. Anterior cervical surgery and percutaneous laser disc decompression are effective for the cervical spondylosis patients accompanied with Barré-Liéou syndrome. As to rotational vertebral artery vertigo, a rare entity, when the exact area of the arterial compression is identified through appropriate tests such as magnetic resonance angiography (MRA), computed tomography angiography (CTA) or digital subtraction angiography (DSA) decompressive surgery should be the chosen treatment.

  9. Cervical Cancer Stage IIIB

    Science.gov (United States)

    ... by the cancer. This blockage can cause the kidney to enlarge or stop working. Stage IIIB cervical cancer. Topics/Categories: Anatomy -- Gynecologic Cancer Types -- Cervical Cancer Staging Type: Color, ...

  10. Narrow Q-switching pulse width and low mode-locking repetition rate Q-switched mode locking with a new coupled laser cavity

    International Nuclear Information System (INIS)

    Peng, J Y; Zheng, Y; Shen, J P; Shi, Y X

    2013-01-01

    An original diode-pumped Q-switched and mode-locked solid state Nd:GdVO 4 laser is demonstrated. The laser operates with double saturable absorbers and a new coupled laser cavity. The Q-switching envelope width is compressed to be about 15 ns and the mode-locking repetition rate is as low as 90 MHz. (paper)

  11. The Biomechanics of Cervical Spondylosis

    Directory of Open Access Journals (Sweden)

    Lisa A. Ferrara

    2012-01-01

    Full Text Available Aging is the major risk factor that contributes to the onset of cervical spondylosis. Several acute and chronic symptoms can occur that start with neck pain and may progress into cervical radiculopathy. Eventually, the degenerative cascade causes desiccation of the intervertebral disc resulting in height loss along the ventral margin of the cervical spine. This causes ventral angulation and eventual loss of lordosis, with compression of the neural and vascular structures. The altered posture of the cervical spine will progress into kyphosis and continue if the load balance and lordosis is not restored. The content of this paper will address the physiological and biomechanical pathways leading to cervical spondylosis and the biomechanical principles related to the surgical correction and treatment of kyphotic progression.

  12. Plate boundary deformation in North Iceland during 1992–2009 revealed by InSAR time-series analysis and GPS

    KAUST Repository

    Metzger, Sabrina

    2014-08-20

    In North Iceland, extensional plate motion is accommodated by the Northern Volcanic Zone, a set of en-echelon volcanic systems, and the Tjörnes Fracture Zone, a transform offset in the mid-Atlantic Ridge consisting of two parallel transform lineaments. The southern lineament, the Húsavík–Flatey fault, is a 100 km-long right-lateral strike slip fault that has not ruptured for more than 140 years and poses a significant seismic hazard to Húsavík, a fishing town located by the fault, and to other coastal communities. We present results of InSAR time-series analysis data spanning almost two decades (1992–2009) that show extensional and interseismic deformation within the Northern Volcanic Zone and the on-shore part of the Tjörnes Fracture Zone. The results also exhibit transient inflation at Theistareykir volcano, deflation at Krafla central volcano and a broad uplift north of Krafla. The current plate extension is not uniform across the Northern Volcanic Zone, but concentrated at the western fissures of the Theistareykir volcanic system and the outermost fissures of the Krafla fissure swarm. We combine a back-slip plate boundary model with a set of point pressure sources representing volcanic changes to describe the current extensional plate boundary deformation and update the previous estimations of the locking depth and slip rate of the Húsavík–Flatey fault that were based on GPS data alone. Using different combinations of input data, we find that the Húsavík–Flatey fault has a locking depth of 6–10 km and, with a slip rate of 6–9 mm/yr, is accommodating about a third of the full transform motion. We furthermore show that while the InSAR data provide important constraints on the volcanic deformation within the NVZ, they do not significantly improve the model parameter estimation for the HFF, as the dense GPS network appears to better capture the deformation across the fault.

  13. Plate boundary deformation in North Iceland during 1992–2009 revealed by InSAR time-series analysis and GPS

    KAUST Repository

    Metzger, Sabrina; Jonsson, Sigurjon

    2014-01-01

    In North Iceland, extensional plate motion is accommodated by the Northern Volcanic Zone, a set of en-echelon volcanic systems, and the Tjörnes Fracture Zone, a transform offset in the mid-Atlantic Ridge consisting of two parallel transform lineaments. The southern lineament, the Húsavík–Flatey fault, is a 100 km-long right-lateral strike slip fault that has not ruptured for more than 140 years and poses a significant seismic hazard to Húsavík, a fishing town located by the fault, and to other coastal communities. We present results of InSAR time-series analysis data spanning almost two decades (1992–2009) that show extensional and interseismic deformation within the Northern Volcanic Zone and the on-shore part of the Tjörnes Fracture Zone. The results also exhibit transient inflation at Theistareykir volcano, deflation at Krafla central volcano and a broad uplift north of Krafla. The current plate extension is not uniform across the Northern Volcanic Zone, but concentrated at the western fissures of the Theistareykir volcanic system and the outermost fissures of the Krafla fissure swarm. We combine a back-slip plate boundary model with a set of point pressure sources representing volcanic changes to describe the current extensional plate boundary deformation and update the previous estimations of the locking depth and slip rate of the Húsavík–Flatey fault that were based on GPS data alone. Using different combinations of input data, we find that the Húsavík–Flatey fault has a locking depth of 6–10 km and, with a slip rate of 6–9 mm/yr, is accommodating about a third of the full transform motion. We furthermore show that while the InSAR data provide important constraints on the volcanic deformation within the NVZ, they do not significantly improve the model parameter estimation for the HFF, as the dense GPS network appears to better capture the deformation across the fault.

  14. John Locke on persons and personal identity

    OpenAIRE

    Boeker, Ruth

    2013-01-01

    John Locke claims both that ‘person’ is a forensic term and that personal identity consists in sameness of consciousness. The aim of my dissertation is to explain and critically assess how Locke links his moral and legal account of personhood to his account of personal identity in terms of sameness of consciousness. My interpretation of Locke’s account of persons and personal identity is embedded in Locke’s sortal-dependent account of identity. Locke’s sortal-dependent ac...

  15. Phase-locked flux-flow Josephson oscillator

    DEFF Research Database (Denmark)

    Ustinov, A. V.; Mygind, Jesper; Oboznov, V. A.

    1992-01-01

    We report on the observation of large rf induced steps due to phase-locking of unidirectional flux-flow motion in long quasi-one-dimensional Josephson junctions. The external microwave irradiation in the frequency range 62–77 GHz was applied from the edge of the junction at which the fluxons enter....... The dependence of the amplitude of the phase-locked step on external magnetic field and microwave power has been measured. The observed zero-crossing steps have potential application in Josephson voltage standards. A simple model for the flux-flow as determined by the microwave driven boundary gate at the edge...

  16. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  17. Development of the Lock Protocol for DEPSKY Storage System

    Directory of Open Access Journals (Sweden)

    NASCIMENTO, P. S.

    2015-06-01

    Full Text Available Data management in environments based on several clouds (cloud-of-clouds should be dependable and secure. DEPSKY may assure that characteristics through mechanisms as cryptography and data replication, however DEPSKY does not support concurrent writing, a desirable functionality for many applications. This paper presents the development and a performance analysis of a lock algorithmfor DEPSKY storage system. The paper also presents validation test and performance test of the algorithm. Such protocol allows concurrent writing, through a low contention lock mechanism that uses lock filesfi to dene who is allowed to write in a data unit.

  18. Mode locking of Yb:GdYAG ceramic lasers with an isotropic cavity

    International Nuclear Information System (INIS)

    Xu, C W; Tang, D Y; Zhu, H Y; Zhang, J

    2013-01-01

    We report on the passive mode locking of a diode pumped Yb:GdYAG ceramic laser with a near isotropic cavity. It is found that the laser could simultaneously mode lock in the two orthogonal principal polarization directions of the cavity, and the mode locked pulses of the two polarizations have identical features and are temporally perfectly synchronized. However, their pulse energy varies out-of-phase periodically, manifesting the antiphase dynamics of mode locked lasers. (letter)

  19. Three Alternative Symbol-Lock Detectors

    Science.gov (United States)

    Shihabi, Mazen M.; Hinedi, Sami M.; Shah, Biren N.

    1993-01-01

    Three symbol-lock detectors proposed as alternatives in advanced receivers processing non-return-to-zero binary data signals. Two perform operations similar to those of older square-law and absolute-value types. However, integrals computed during nonoverlapping symbol periods and, therefore, only one integrator needed in each such detector. Proposed detectors simpler, but performances worse because noises in overlapping samples correlated, whereas noises in nonoverlapping samples not correlated. Third detector is signal-power-estimator type. Signal integrated during successive half symbol cycles, and therefore only one integrator needed. Half-cycle integrals multiplied to eliminate effect of symbol polarity, and products accumulated during M-cycle observation period to smooth out estimate of signal power. If estimated signal power exceeds threshold, delta, then lock declared.

  20. Cervical Chondrocutaneous Branchial Remnants.

    Science.gov (United States)

    Klockars, Tuomas; Kajosaari, Lauri

    2017-03-01

    Cervical chondrocutaneous branchial remnants are rare malformations usually found in the lower neck. As high as 76% of patients have been reported to have associated anomalies. We review the literature and report a case series of seven patients with cervical cartilaginous remnants.   A retrospective case series of seven patients identified from the electronic hospital records.   Seven patients with cervical chondrocutaneous branchial remnants were identified (six boys and one girl). Only one of the patients had associated anomalies.   A review of the literature revealed no evidence for sinuses or cysts related to cervical chondrocutaneous branchial remnants. Operative treatment can be postponed to a suitable and safe age. There is marked variation in the reported prevalence of associated anomalies, ranging from 11% to 76%.