WorldWideScience

Sample records for cerebral computed tomography

  1. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  2. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  3. Computed tomography of cerebral palsy

    International Nuclear Information System (INIS)

    Seventy patients who had suffered from severe damages in the brain in their early lives were examined using a CT scanner, DELTA-25. The results are summerized as follows: 1. CT findings of the brain were classified into four groups; (1) low density in 11 cases, (2) atrophy in 23, (3) hydrocephalus in 12, and (4) no findings in 24. 2. The low density in the CT finding was assumed as cystic degeneration due to circulatory disturbance in the cerebral hemispheres in their early developmental stages. 3. The ''acerebrate'' state denotes no or little development in mental and motor functions which is attributed to a severe damage in the developing brain. According to the CT findings, the ''acerebrate'' state was resulted from extensive destruction in the greater part of both hemispheres. (author)

  4. Spontaneous cerebral intraparenchymatous hematoma: computed tomography findings

    International Nuclear Information System (INIS)

    The objective of this study was to identify the most frequent aspects of spontaneous cerebral intraparenchymatous hematoma found at computed tomography examinations. We reviewed, retrospectively, the computed tomography studies of 250 patients with spontaneous intracerebral hemorrhage carried out in three hospitals in Rio de Janeiro, Brazil. The results showed deep intracerebral hematomas showed the highest incidence and were observed in 54.4% of the cases (136 patients) followed by lobar hemorrhage in 34.8% of the cases (87 patients). Cerebellar hemorrhage and brainstem bleeding were more rarely observed, occurring in 8.4% (21 patients) and 2.4% (six patients) of the cases, respectively. Chronic headache was the most frequent symptom whereas hypertension was observed in the majority of the cases. Blood draining into the ventricular system occurred more frequently in patients with deep hematomas. (author)

  5. Human cerebral asymmetries evaluated by computed tomography

    International Nuclear Information System (INIS)

    The handedness of seventy-five persons without evidence of neurological disease, was assessed with a standardised test. An analysis of the CT scans of the same persons was performed to determine (1) presence and lateralisation of frontal and occipital 'petalia', (2) width of frontal and occipital lobes of each hemisphere, (3) direction of straight sinus deviation. Results suggest that handedness and cerebral asymmetries are independent variables. There were no significant differences between right-handers and non-right handers. Also there was no significant differences between strongly left-handed and ambidextrous individuals, nor were there differences between right-handers with or without family history of left-handedness. Irrespective of handedness, left occipital 'petalia' was more common than right (p<0.01), right frontal petalia was more common than left (p<0.01), and straight sinus deviation was more commonly toward the right. The study does not support the concept that cerebral 'symmetry' or 'reverse asymmetry' are associated with left-handedness or ambidexterity. The noted asymmetries are more likely to be direct correlates of cerebral language dominance, than of handedness. Outside forces acting on the bone may also contribute to the asymmetries. CT scan may be of value as a direct predictor of cerebral dominance. (author)

  6. Computed tomography in spastic cerebral palsy

    International Nuclear Information System (INIS)

    Eigthy-three children with spastic cerebral plays (CP) were examined with cranial CT. In 56 cases the CT findings were abnormal. The most frequent abnormality was atrophy, present in 44 patients. The frequency of pathologic CT increased with severity of the CP. Patients with CP of postnatal aetiology more often had abnormal CT than patients with other known causes. Pathologic CT findings were seen more often in patients with seizures than in patients without. Infarctions and hemiatrophy were much more frequent in patients with hemiplegia than in patients with other types of spastic CP. A special kind of central atrophy, called isolated atrophy around the cella media, is described. This condition was seen in 20% of cases, most often in hemi- and paraplegic patients. Early infarctions in the border areas between the vasular territories of the internal carotid and the posterior cerebral artery may be the reason for this kind of atrophy. (orig.)

  7. Computed tomography in spastic cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, H.; Taudorf, K.; Melchior, J.C.

    1982-09-01

    Eighty-three children with spastic cerebral palsy (CP) were examined with cranial CT. In 56 cases the CT findings were abnormal. The most frequent abnormality was atrophy, present in 44 patients. The frequency of pathologic CT increased with severity of the CP. Patients with CP of postnatal aetiology more often had abnormal CT than patients with other known causes. Pathologic CT findings were seen more often in patients with seizures than in patients without. Infarctions and hemiatrophy were much more frequent in patients with hemiplegia than in patients with other types of spastic CP. A special kind of central atrophy, called isolated atrophy around the cella media, is described. This condition was seen in 20% of cases, most often in hemi- and paraplegic patients. Early infarctions in the border areas between the vascular territories of the internal carotid and the posterior cerebral artery may be the reason for this kind of atrophy.

  8. The value of computed tomography in cerebral syphilis

    International Nuclear Information System (INIS)

    The computed tomographic findings of three patients with cerebral syphilis, including cerebral gumma, which regressed completely under penicillin therapy, syphilitic angiitis with cerebral infarction, and syphilitic cerebral atrophy, are reported CT is unable to provide specific diagnostic data for these conditions. The etiology can be clarified only by taking into consideration the clinical findings and course, the serological results, and the result of therapy. (orig.)

  9. Age-related cerebral white matter changes on computed tomography

    International Nuclear Information System (INIS)

    Changes of cerebral white matter on computed cranial tomography related to aging were studied in 70 subjects aged 30 to 94 years. The subjects had no histories of cerebrovascular accidents and no abnormalities in the central nervous system were shown by physical examinations and CT scans. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39cm2) in the bilateral thalamus and twelve areas of deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size and cranial bone CT numbers on the brain CT numbers. We also studied the association between brain CT numbers and brain atrophy, hypertension, diabetes mellitus. CT numbers of frontal white matter surrounding anterior horns decreased with aging in 70 subjects aged 30 to 94 years. No significant correlation between age and brain CT numbers was found in any other region by multivariate analysis, because of the prominent effect of cranial bone CT numbers on brain CT numbers. Although no age-related changes of white matter CT numbers was found in 41 subjects aged 30 to 65 years, there were significant negative correlations between age and white matter CT numbers at all regions in 29 subjects aged 66 to 94 years. Brain atrophy was associated with brain CT numbers. No association was found for hypertension or diabetes mellitus. Brain CT numbers decreased with aging even in neurologically healthy persons in older age. Brain CT numbers also decreased as cerebral atrophy advanced. (author)

  10. Age-related cerebral white matter changes on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Kouichi; Tsunematsu, Tokugoro

    1989-01-01

    Changes of cerebral white matter on computed cranial tomography related to aging were studied in 70 subjects aged 30 to 94 years. The subjects had no histories of cerebrovascular accidents and no abnormalities in the central nervous system were shown by physical examinations and CT scans. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39cm/sup 2/) in the bilateral thalamus and twelve areas of deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size and cranial bone CT numbers on the brain CT numbers. We also studied the association between brain CT numbers and brain atrophy, hypertension, diabetes mellitus. CT numbers of frontal white matter surrounding anterior horns decreased with aging in 70 subjects aged 30 to 94 years. No significant correlation between age and brain CT numbers was found in any other region by multivariate analysis, because of the prominent effect of cranial bone CT numbers on brain CT numbers. Although no age-related changes of white matter CT numbers was found in 41 subjects aged 30 to 65 years, there were significant negative correlations between age and white matter CT numbers at all regions in 29 subjects aged 66 to 94 years. Brain atrophy was associated with brain CT numbers. No association was found for hypertension or diabetes mellitus. Brain CT numbers decreased with aging even in neurologically healthy persons in older age. Brain CT numbers also decreased as cerebral atrophy advanced. (author).

  11. Studies of cerebrovascular lesion by computer tomography, cerebral scintigrapy and EEG in longitudinal section

    International Nuclear Information System (INIS)

    A long-term follow-up of an intracerebral hemorrhage by computer tomography, cerebral scintigraphy and EEG is reported. In the acute phase of the cerebral hemorrhage, EEG, computer tomography and scintigraphy are equally useful diagnostic techniques. In the recovery phase of the hemorrhage only the results of computer tomography fitted with the clinical status of the patients. In this phase of hemorrhage, scintigraphy was less sensitive in the following of the regeneration of cerebral circulation than in the previous phases. (L.G.)

  12. Spontaneous cerebral intraparenchymatous hematoma: computed tomography findings; Hematoma intraparenquimatoso cerebral espontaneo: aspectos a tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Celso Monteiro [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Programa de Pos-graduacao em Radiologia]. E-mail: celsomsoares@ig.com.br; Carvalho, Antonio Carlos Pires [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia

    2001-02-01

    The objective of this study was to identify the most frequent aspects of spontaneous cerebral intraparenchymatous hematoma found at computed tomography examinations. We reviewed, retrospectively, the computed tomography studies of 250 patients with spontaneous intracerebral hemorrhage carried out in three hospitals in Rio de Janeiro, Brazil. The results showed deep intracerebral hematomas showed the highest incidence and were observed in 54.4% of the cases (136 patients) followed by lobar hemorrhage in 34.8% of the cases (87 patients). Cerebellar hemorrhage and brainstem bleeding were more rarely observed, occurring in 8.4% (21 patients) and 2.4% (six patients) of the cases, respectively. Chronic headache was the most frequent symptom whereas hypertension was observed in the majority of the cases. Blood draining into the ventricular system occurred more frequently in patients with deep hematomas. (author)

  13. Abnormalities of cerebral blood flow: Investigation by intravenous digital substraction angiography and computed tomography

    International Nuclear Information System (INIS)

    In 110 patients with signs of cerebral infarct computed tomography (CT) and intravenous digital subtraction angiography (DSA) were performed. With DSA 63 arterial wall lesions could be seen, in CT 27 infarcts were found. In 9 examinations DSA was not diagnostic. Combination of both methods makes it possible to relate vascular lesions with size and localisation of cerebral infarcts. (orig.)

  14. Selective value of computed tomography of the brain in Cerebritis due to systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Gaylis, N.B.; Altman, R.D.; Ostrov, S.; Quencer, R. (Miami Univ., FL (USA). School of Medicine)

    Systemic lupus erythematosus (SLE) and steroid effects on the brain were measured by computed tomography (CT). Of 14 patients with SLE cerebritis, 10 (71%) had marked cortical atrophy and 4 (29%) minimal atrophy. None were normal by CT. Controls included 22 patients with SLE without cerebritis receiving cortiocosteroids; this group had normal CT scans in 16 (73%) and minimal cortical atrophy in the remaining 6 (27%). Follow-up CT on 5 patients with cerebritis was unchanged. CT of the brain is a minimally invasive technique for documenting SLE cerebritis. CT may also help differentiate cerebritis from the neuropsychiatric side effects of corticosteroids.

  15. The selective value of computed tomography of the brain in Cerebritis due to systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Systemic lupus erythematosus (SLE) and steroid effects on the brain were measured by computed tomography (CT). Of 14 patients with SLE cerebritis, 10 (71%) had marked cortical atrophy and 4 (29%) minimal atrophy. None were normal by CT. Controls included 22 patients with SLE without cerebritis receiving cortiocosteroids; this group had normal CT scans in 16 (73%) and minimal cortical atrophy in the remaining 6 (27%). Follow-up CT on 5 patients with cerebritis was unchanged. CT of the brain is a minimally invasive technique for documenting SLE cerebritis. CT may also help differentiate cerebritis from the neuropsychiatric side effects of corticosteroids

  16. Value of three-dimensional computed tomography in screening cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Tamaki; Sugiura, Yusuke; Suzuki, Atsushi; Yamagata, Yoshitaka [Hyogo Medical Coll. (Japan)

    1997-10-01

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  17. Value of three-dimensional computed tomography in screening cerebral aneurysms

    International Nuclear Information System (INIS)

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  18. Early cerebral circulatory disturbance in patients suffering subarachnoid hemorrhage prior to the delayed cerebral vasospasm stage. Xenon computed tomography and perfusion computed tomography study

    International Nuclear Information System (INIS)

    Subarachnoid hemorrhage (SAH) causes dynamic changes in cerebral blood flow (CBF), and results in delayed ischemia due to vasospasm, and early perfusion deficits before delayed cerebral vasospasm (CVS). The present study examined the severity of cerebral circulatory disturbance during the early phase before delayed CVS and whether it can be used to predict patient outcome. A total of 94 patients with SAH underwent simultaneous xenon computed tomography (CT) and perfusion CT to evaluate cerebral circulation on Days 1-3. Cerebral blood flow (CBF) was measured using xenon CT and the mean transit time (MTT) using perfusion CT and calculated cerebral blood volume (CBV). Outcome was evaluated with the Glasgow Outcome Scale (good recovery [GR], moderate disability [MD], severe disability [SD], vegetative state [VS], or death [D]). Hunt and Hess (HH) grade II patients displayed significantly higher CBF and lower MTT than HH grade IV and V patients. HH grade III patients displayed significantly higher CBF and lower MTT than HH grade IV and V patients. Patients with favorable outcome (GR or MD) had significantly higher CBF and lower MTT than those with unfavorable outcome (SD, VS, or D). Discriminant analysis of these parameters could predict patient outcome with a probability of 74.5%. Higher HH grade on admission was associated with decreased CBF and CBV and prolonged MTT. CBF reduction and MTT prolongation before the onset of delayed CVS might influence the clinical outcome of SAH. These parameters are helpful for evaluating the severity of SAH and predicting the outcomes of SAH patients. (author)

  19. Cerebral blood flow measurements using electron beam computed tomography (EBT)

    International Nuclear Information System (INIS)

    In close collaboration with the participants of the TEMPUS-Project Nr. 11117 a new technical and theoretical approach was developed to estimate cerebral blood flow using i.v. applied contrast agent and evaluating the cerebral time density curves using EBT as imaging method. This new approach and first clinical results are described. (author)

  20. Cerebral computed tomography in men with acquired immunodeficiency syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brun, B.; Boesen, F.; Gerstoft, J.; Nielsen, J.O.; Praestholm, J.

    Cerebral CT scannings were performed in 19 homosexual men with the acquired immunodeficiency syndrome (AIDS). Nearly half of them (9 patients) had cortical atrophy. Three patients with toxoplasmosis had cerebral pathology, in two of them with ring enhancement while the third had an ill-defined nonspecific lesion with slight heterogeneous enhancement without ring formation. Two patients with multifocal leucoencephalopathy and non-Hodgkin's lymphoma, respectively, presented non-enhancing, low attenuating lesions at CT.

  1. Cerebral computed tomography in men with acquired immunodeficiency syndrome

    International Nuclear Information System (INIS)

    Cerebral CT scannings were performed in 19 homosexual men with the acquired immunodeficiency syndrome (AIDS). Nearly half of them (9 patients) had cortical atrophy. Three patients with toxoplasmosis had cerebral pathology, in two of them with ring enhancement while the third had an ill-defined nonspecific lesion with slight heterogeneous enhancement without ring formation. Two patients with multifocal leucoencephalopathy and non-Hodgkin's lymphoma, respectively, presented non-enhancing, low attenuating lesions at CT. (orig.)

  2. Computer tomography in the diagnosis of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Marinsek-Cicin-Sain, V.; Besenski, N.; Jelicic, I.; Broz, R.

    1984-01-01

    Cerebral cystiscercosis was diagnosed in 16 patients by CT, both before and after contrast injection. In six patients the findings were confirmed at operation and histologically. In ten patients, the diagnosis was supported by typical findings on conventional radiographs of the thighs, calves and skull. The CT findings permitted classification of the patients into three types of disease.

  3. Computer tomography in the diagnosis of cerebral cysticercosis

    International Nuclear Information System (INIS)

    Cerebral cystiscercosis was diagnosed in 16 patients by CT, both before and after contrast injection. In six patients the findings were confirmed at operation and histologically. In ten patients, the diagnosis was supported by typical findings on conventional radiographs of the thighs, calves and skull. The CT findings permitted classification of the patients into three types of disease. (orig.)

  4. Validation of enhanced and dynamic computed tomography for cerebral ischemia

    International Nuclear Information System (INIS)

    This paper shows the usefulness of enhanced and dynamic CT for ischemic stroke patients. Sixteen patients with disturbance of consciousness or neurological sign who did not have low-density area on plain CT were selected for this study. We performed enhanced CT sequentially. Enhanced CT image, time-density curve and functional image were compared with final infarcted area and occlusion level of cerebral artery. Three patients whose enhanced CT images showed obvious laterality had occlusion of internal carotid (IC) or horizontal portion of middle cerebral artery (M1). Four of five patients whose functional image and time density curve revealed abnormal region had ischemia because of more peripheral vessel occlusion or IC stenosis. Others with no abnormality on all images had lacunar infarction or did not have infarction finally. Occlusion of cerebral artery proximal portion could be diagnosed only with enhanced CT images. If selected slice was fit to the lesion, more distant level of ischemic area could be determined 100% by time-density curve and functional image. This examination takes only about ten minutes without transferring the patient. Enhanced CT and dynamic scan is useful tool to determine the diagnosis and management for ischemic stroke patients. (author)

  5. Hematoma intraparenquimatoso cerebral espontâneo: aspectos à tomografia computadorizada Spontaneous cerebral intraparenchymatous hematoma: computed tomography findings

    Directory of Open Access Journals (Sweden)

    Celso Monteiro Soares

    2005-02-01

    Full Text Available OBJETIVO: Identificar os aspectos mais freqüentes do hematoma intraparenquimatoso cerebral espontâneo observados na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram analisados, retrospectivamente, os exames de tomografia computadorizada de 250 pacientes com hematoma intraparenquimatoso cerebral espontâneo, provenientes de três diferentes hospitais da cidade do Rio de Janeiro. RESULTADOS: O hematoma intraparenquimatoso cerebral profundo foi o de maior incidência, equivalendo a 54,4% (136 casos, seguido do lobar com 34,8% (87 casos. Mais raramente, observou-se sangramento cerebelar em 8,4% (21 casos e do tronco cerebral em 2,4% (seis casos dos pacientes. CONCLUSÃO: A cefaléia foi o sintoma mais comum e a hipertensão arterial foi o sinal mais freqüentemente apresentado. A drenagem do hematoma para o sistema ventricular ocorreu mais comumente nos hematoma profundos.OBJECTIVE: To identify the most frequent aspects of spontaneous cerebral intraparenchymatous hematoma found at computed tomography examinations. MATERIALS AND METHODS: We reviewed, retrospectively, the computed tomography studies of 250 patients with spontaneous intracerebral hemorrhage carried out in three hospitals in Rio de Janeiro, Brazil. RESULTS: Deep intracerebral hematomas showed the highest incidence and were observed in 54.4% of the cases (136 patients followed by lobar hemorrhage in 34.8% of the cases (87 patients. Cerebelar hemorrhage and brainstem bleeding were more rarely observed, occurring in 8.4% (21 patients and 2.4% (six patients of the cases, respectively. CONCLUSION: Chronic headache was the most frequent symptom whereas hypertension was observed in the majority of the cases. Blood draining into the ventricular system occurred more frequently in patients with deep hematomas.

  6. Study of regional cerebral metabolic rate of glucose with positron emission computed tomography in Alzheimer's disease

    International Nuclear Information System (INIS)

    Using positron emission computed tomography with F-18 fluoro-D-deoxyglucose, regional cerebral metabolic rate of glucose (rCMRglc) was measured in 8 patients with Alzheimer's disease and 3 healthy volunteers. A decreased rCMRglc was observed in the widespread cortex and basal ganglia of the cerebrum, but not observed in white matter, thalamus, and cerebellum. There was no bilateral difference. rCMRglc was the lowest in the parietal lobe, followed by the temporal lobe and the curvature of the frontal lobe. A decrease in rCMRglu was relatively mild in the inner part of the frontal lobe, primary sensory and motor area of the cerebral cortex, and cerebral basilar ganglia. Alzheimer's disease proved to be characterized by severe glucose metabolic disorder in the association area of the bilateral cerebral cortices. The degree of metabolic disorder was correlated with the degree of dementia in the outer part of the left frontal lobe and the curvature of the cerebral cortex. (Namekawa, K.)

  7. Cerebral blood flow determination within the first 8 hours of cerebral infarction using stable xenon-enhanced computed tomography

    International Nuclear Information System (INIS)

    Cerebral blood flow mapping with stable xenon-enhanced computed tomography (Xe/CT) was performed in conjunction with conventional computed tomography (CT) within the first 8 hours after the onset of symptoms in seven patients with cerebral infarction. Six patients had hemispheric infarctions, and one had a progressive brainstem infarction. Three patients with very low (less than 10 ml/100 g/min) blood flow in an anatomic area appropriate for the neurologic deficit had no clinical improvement by the time of discharge from the hospital; follow-up CT scans of these three patients confirmed infarction in the area of very low blood flow. Three patients with moderate blood flow reductions (15-45 ml/100 g/min) in the appropriate anatomic area had significant clinical improvement from their initial deficits and had normal follow-up CT scans. One patient studied 8 hours after stroke had increased blood flow (hyperemia) in the appropriate anatomic area and made no clinical recovery

  8. Assessing regional cerebral blood flow in depression using 320-slice computed tomography.

    Directory of Open Access Journals (Sweden)

    Yiming Wang

    Full Text Available While there is evidence that the development and course of major depressive disorder (MDD symptomatology is associated with vascular disease, and that there are changes in energy utilization in the disorder, the extent to which cerebral blood flow is changed in this condition is not clear. This study utilized a novel imaging technique previously used in coronary and stroke patients, 320-slice Computed-Tomography (CT, to assess regional cerebral blood flow (rCBF in those with MDD and examine the pattern of regional cerebral perfusion. Thirty nine participants with depressive symptoms (Hamilton Depression Rating Scale 24 (HAMD24 score > 20, and Self-Rating Depression Scale (SDS score > 53 and 41 healthy volunteers were studied. For all subjects, 3 ml of venous blood was collected to assess hematological parameters. Transcranial Doppler (TCD ultrasound was utilized to measure parameters of cerebral artery rCBFV and analyse the Pulsatility Index (PI. 16 subjects (8 =  MDD; 8 =  healthy also had rCBF measured in different cerebral artery regions using 320-slice CT. Differences among groups were analyzed using ANOVA and Pearson's tests were employed in our statistical analyses. Compared with the control group, whole blood viscosity (including high\\middle\\low shear rateand hematocrit (HCT were significantly increased in the MDD group. PI values in different cerebral artery regions and parameters of rCBFV in the cerebral arteries were decreased in depressive participants, and there was a positive relationship between rCBFV and the corresponding vascular rCBF in both gray and white matter. rCBF of the left gray matter was lower than that of the right in MDD. Major depression is characterized by a wide range of CBF impairments and prominent changes in gray matter blood flow. 320-slice CT appears to be a valid and promising tool for measuring rCBF, and could thus be employed in psychiatric settings for biomarker and treatment response purposes.

  9. A CASE OF POLYCYTHEMIA SHOWING HYPERDENSE CEREBRAL VESSELS ON NON-CONTRAST COMPUTED TOMOGRAPHY SCAN

    Directory of Open Access Journals (Sweden)

    Bijit Kr

    2015-12-01

    Full Text Available Polycythemia is a disease state in which the proportion of blood volume that is occupied by red blood cells increases. It can result in increased density of intracranial blood vessels on non-contrast computed tomography scan. This imaging findings can closely mimic appearance of a contrast enhanced CT scan and those of cerebral venous thrombosis. We are presenting a case of 11-year-old child with Fallot’s tetralogy who showed abnormally hyperdense intracranial vessels on NCCT of brain.

  10. Semiquantitative dynamic computed tomography to predict response to anti-platelet therapy in acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chokyu, K.; Shimizu, K. [Department of Neurosurgery, Kochi Medical School, Kohasu (Japan); Fukumoto, M. [Department of Radiology, Kochi Medical School (Japan); Mori, T. [Department of Stroke Treatment, Shonan Kamakura General Hospital, Kanagawa (Japan); Mokudai, T.; Mori, K. [Mominoki Hospital, Kochi (Japan)

    2002-04-01

    We investigated whether dynamic computed tomography (CT) in patients with acute cerebral infarction could identify patients likely to respond to anti-platelet therapy. Seventy patients underwent semiquantitative dynamic CT within 6 h as well as cerebral angiography. All then received anti-platelet therapy with a thromboxane A2 synthetase inhibitor. Peak value (pv) and time-to-peak (tp) (time-density curves) for the Sylvian fissure were extracted from dynamic CT data and standardizing interpatient data, two indices, PV/TP index and TP index, were prepared following a standard semiquantitative manner. Both PV/TP index and TP index were effective in discriminating between 48 responders (modified Rankin scale (mRS): 0 to 2) and 22 non-responders (mRS: 3 to 5, or death: 6; both P<0.0001). High PV/TP index ({>=}0.8) was a strong indicator of favorable response. Most of these patients maintained regional cerebral blood flow (rCBF) via anterograde flow or collaterals, with a TP index {<=}1.1. Low PV/TP index ({<=}0.4) predicted non-response associated with increased TP index (>1.1) and non-compensated rCBF. Intermediate PV/TP values could not predict outcome. Dynamic CT prior to therapy can identify patients with acute cerebral infarction who are treatable with anti-platelet therapy alone. (orig.)

  11. Racking the brain: Detection of cerebral edema on postmortem computed tomography compared with forensic autopsy

    International Nuclear Information System (INIS)

    Graphical abstract: -- Highlights: •Postmortem swelling of the brain is a typical finding on PMCT and occurs concomitant with potential antemortem or agonal brain edema. •Cerebral edema despite normal postmortem swelling is indicated by narrowed temporal horns and symmetrical herniation of the cerebral tonsils on PMCT. •Cases with intoxication or asphyxia demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units) and a ratio >1.58 between the gray and white matter. •The Hounsfield measurements of the white and gray matter help to determine the cause of death in cases of intoxication or asphyxia. -- Abstract: Purpose: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. Materials and methods: The study collective included a total of 109 cases (n = 109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. Results: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p < 0.001). There was a significant difference (p < 0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to

  12. Racking the brain: Detection of cerebral edema on postmortem computed tomography compared with forensic autopsy

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Nicole [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Ampanozi, Garyfalia; Schweitzer, Wolf; Ross, Steffen G.; Gascho, Dominic [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Ruder, Thomas D. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic, Interventional and Pediatric Radiology, University Hospital of Bern, Freiburgstrasse, 3010 Bern (Switzerland); Thali, Michael J. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.uzh.ch [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2015-04-15

    Graphical abstract: -- Highlights: •Postmortem swelling of the brain is a typical finding on PMCT and occurs concomitant with potential antemortem or agonal brain edema. •Cerebral edema despite normal postmortem swelling is indicated by narrowed temporal horns and symmetrical herniation of the cerebral tonsils on PMCT. •Cases with intoxication or asphyxia demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units) and a ratio >1.58 between the gray and white matter. •The Hounsfield measurements of the white and gray matter help to determine the cause of death in cases of intoxication or asphyxia. -- Abstract: Purpose: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. Materials and methods: The study collective included a total of 109 cases (n = 109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. Results: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p < 0.001). There was a significant difference (p < 0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to

  13. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    We have performed single photon emission computed tomography (SPECT) with 99mTc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  14. The value of multi-slice computed tomography for early diagnosis of focal cerebral ischemia

    International Nuclear Information System (INIS)

    The aim of this survey is the characterization of the present value of multi-slice computed tomography (MSCT) for the assessment of hyperacute cerebral ischemia based on our experience and a review of the literature. MSCT is compared with single-slice CT (SSCT) as to the diagnostic value of standard cranial CT, CT angiography (CTA) and perfusion CT. CTA obtained with MSCT surpasses CTA obtained with SSCT. For perfusion CT, the value added by MSCT is small. With regard to standard cranial CT, MSCT and SSCT are considered equivalent. CTA and perfusion CT should be used in patients with acute stroke if the indication for thrombolysis is entertained but diffusion and perfusion weighted MRI cannot be carried out. This applies to both SSCT and MSCT. If advanced MRI and advanced CT are available, MRI continues to be the preferred imaging modality. (orig.)

  15. Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography

    Institute of Scientific and Technical Information of China (English)

    Yong Huang; Yangjia Lu; Ganlong Li; Xinsheng Lai; Hong Zhang; Chunzhi Tang; Junjun Yang

    2011-01-01

    The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.

  16. A method for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Celsis, P; Goldman, T; Henriksen, L; Lassen, N A

    1981-01-01

    Emission tomography of positron or gamma emitting inert gases allows calculation of regional cerebral blood flow (rCBF) in cross-sectional slices of human brain. An algorithm is presented for rCBF calculations from a sequence of time averaged tomograms using inhaled 133Xe. The approach is designe...

  17. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome.

    Directory of Open Access Journals (Sweden)

    Chien Hung Chang

    Full Text Available BACKGROUND: Hyperperfusion syndrome (HPS following carotid angioplasty with stenting (CAS is associated with significant morbidity and mortality. At present, there are no reliable parameters to predict HPS. The aim of this study was to clarify whether perfusion computed tomography (CT is a feasible and reliable tool in predicting HPS after CAS. METHODOLOGY/PRINCIPAL FINDINGS: We performed a retrospective case-control study of 54 patients (11 HPS patients and 43 non-HPS with unilateral severe stenosis of the carotid artery who underwent CAS. We compared the prevalence of vascular risk factors and perfusion CT parameters including regional cerebral blood volume (rCBV, regional cerebral blood flow (rCBF, and time to peak (TTP within seven days prior to CAS. Demographic information, risk factors for atherosclerosis, and perfusion CT parameters were evaluated by multivariable logistic regression analysis. The rCBV index was calculated as [(ipsilateral rCBV - contralateral rCBV/contralateral rCBV], and indices of rCBF and TTP were similarly calculated. We found that eleven patients had HPS, including five with intracranial hemorrhages (ICHs of whom three died. After a comparison with non-HPS control subjects, independent predictors of HPS included the severity of ipsilateral carotid artery stenosis, 3-hour mean systolic blood pressure (3 h SBP after CAS, pre-stenting rCBV index >0.15 and TTP index >0.22. CONCLUSIONS/SIGNIFICANCE: The combination of severe ipsilateral carotid stenosis, 3 h SBP after CAS, rCBV index and TTP index provides a potential screening tool for predicting HPS in patients with unilateral carotid stenosis receiving CAS. In addition, adequate management of post-stenting blood pressure is the most important treatable factor in preventing HPS in these high risk patients.

  18. Objective Quantification of the Regional Distribution of Radioactivity in Cerebral Emission Computed Tomography

    Science.gov (United States)

    Harris, Gordon Jonathan

    It is essential in the analysis of emission computed tomography (ECT) scans of the living human brain to be able to reliably and objectively obtain regional quantitative data. Therefore, the following thesis describes new methods for the analysis of the regional distribution of radioactivity in brain ECT images, which reduces the variability inherent in observer guided region of interest placement. The analysis methods developed include the definition of a cortical ring for producing a "cortical circumferential profile" of the cortical distribution of radioactivity. This method treats the cortex as a continuous annulus on the outer brain rim. The outer boundary of the brain can be defined either manually, or using a matched, registered magnetic resonance image (MRI), which can also be used for analysis of discrete subcortical regions, a difficult task using ECT images alone. The methods developed here were then applied to the analysis of alterations in the regional cerebral perfusion patterns which are seen in neuro-psychiatric illness. Alzheimer's Dementia, Obsessive-Compulsive Disorder and HIV Dementia were all found to have perfusion abnormalities compared to matched control groups.

  19. Positron computed tomography studies of cerebral metabolic responses to complex motor tasks

    International Nuclear Information System (INIS)

    Human motor system organization was explored in 8 right-handed male subjects using /sup 18/F-fluorodeoxyglucose and positron computed tomography to measure cerebral glucose metabolism. Five subjects had triple studies (eyes closed) including: control (hold pen in right hand without moving), normal size writing (subject repeatedly writes name) and large (10-15 X normal) name writing. In these studies normal and large size writing had a similar distribution of metabolic responses when compared to control studies. Activations (percent change from control) were in the range of 12-20% and occurred in the striatum bilaterally > contralateral Rolandic cortex > contralateral thalamus. No significant activations were observed in the ipsilateral thalamus, Rolandic cortex or cerebellum (supplementary motor cortex was not examined). The magnitude of the metabolic response in the striatum was greater with the large versus normal sized writing. This differential response may be due to an increased number and topographic distribution of neurons responding with the same average activity between tasks or an increase in the functional activity of the same neuronal population between the two tasks (present spatial resolution inadequate to differentiate). When subjects (N=3) performed novel sequential finger movements, the maximal metabolic response was in the contralateral Rolandic cortex > striatum. Such studies provide a means of exploring human motor system organization, motor learning and provide a basis for examining patients with motor system disorders

  20. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi [Iwate Medical Univ., Morioka (Japan). School of Medicine

    2002-04-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23{+-}10 cm/sec in 21 FDE cases, 14{+-}3 cm/sec in 3 FDL-1 cases, 29{+-}23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58{+-}25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  1. Regional cerebral blood flow analysis of vascular dementia by the single photon emission computed tomography

    International Nuclear Information System (INIS)

    In order to evaluate the relationship between the regional cerebral blood flow (CBF) and cerebrovascular dementia, eleven patients with vascular dementia and eight patients with non-demented infarction were studied and regional CBF were measured quantitatively with single photon emission computed tomography (SPECT) by using N-isopropyl-p-(I-123) iodoamphetamine. All cases were basal infarction and vascular dementia were diagnosed by less than 21.5 of the Hasegawa's dementia score and more than 7 of Hachinsk's ischemic score. The results of the present study were as follows: (1) Cerebrovascular dementia showed lower mean CBF value compared with non-demented group. (2) Regional CBF of bilateral frontal areas and affected basal ganglia were significantly reduced than occipital area in the dementia group. (3) A comparison of regional CBF and the Hasegawa's dementia score revealed a statistically significant correlation at the bilateral frontal areas in the dementia group. It is possible that measuring the regional CBF quantitatively by IMP-SPECT is useful for clinical analysis of vascular dementia. (author)

  2. Prediction of effectiveness of shunting in patients with normal pressure hydrocephalus by cerebral blood flow measurement and computed tomography cisternography

    International Nuclear Information System (INIS)

    Measurement of cerebral blood flow (CBF) and computed tomography (CT) cisternography were performed in 37 patients with a tentative diagnosis of normal pressure hydrocephalus (NPH) to predict their surgical outcome. The mean CBF of the whole brain was measured quantitatively by single photon emission computed tomography with technetium-99m-hexamethylpropylene amine oxime before surgery. The results of CT cisternography were classified into four patients: type I, no ventricular stasis at 24 hours; type II, no ventricular stasis with delayed clearance of cerebral blush; type III, persistent ventricular stasis with prominent cerebral blush; type IV, persistent ventricular stasis with diminished cerebral blush and/or asymmetrical filling of the sylvian fissures. The mean CBF was significantly lower than that of age-matched controls (p<0.005). Patients with a favorable outcome had a significantly higher mean CBF than patients with an unfavorable outcome (p<0.005). Patients with the type I pattern did not respond to shunting. Some patients with type II and III patterns responded to shunting but improvement was unsatisfactory. Patients with type IV pattern responded well to shunting, and those with a mean CBF of 35 ml/100 g/min or over achieved a favorable outcome. The combination of CBF measurement and CT cisternography can improve the prediction of surgical outcome in patients with suspected NPH. (author)

  3. Association between carotid plaque composition assessed by multidetector computed tomography and cerebral embolism after carotid stenting

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Naoyuki [Kanazawa University, Department of Neurosurgery and Radiology, Graduate School of Medical Science, Kanazawa (Japan); Kanazawa University, Department of Neurosurgery, Division of Neuroscience, Graduate School of Medical Science, Kanazawa, Ishikawa (Japan); Misaki, Kouichi; Mohri, Masanao; Watanabe, Takuya; Hirota, Yuichi; Nakada, Mitsutoshi; Hayashi, Yutaka; Ueda, Fumiaki; Hamada, Jun-ichiro [Kanazawa University, Department of Neurosurgery and Radiology, Graduate School of Medical Science, Kanazawa (Japan)

    2012-05-15

    We aimed to assess the relationship between atherosclerotic carotid plaque composition analyzed using multidetector computed tomography (MDCT) and the appearance of new ischemic lesions detected by diffusion-weighted images (DWI) after carotid artery stenting (CAS). We quantitatively and qualitatively analyzed plaque characteristics in carotid arteries using MDCT before CAS in 19 patients. Carotid plaques were expediently subdivided into four components with Hounsfield unit (HU) values of <0, 0-60, 60-130, and >600. The incidence of distal embolism was evaluated with DWI. Pearson's correlation analyses were used to assess the association between plaque composition and the incidence of cerebral embolization. Fifteen patients (79%) demonstrated new DWI lesions after CAS. High-signal DWIs were noted as follows: one in six patients, 2{proportional_to}5 in five patients, 6{proportional_to}10 in two patients, and >10 in two patients. The mean volumes of the plaque components for HU < 0, 0-60, 60-130, and >600 were 5.4, 200, 260, and 59 mm{sup 3}, respectively. There was a strong correlation between the number of high-signal DWI lesions in the ipsilateral side and the plaque volume of HU < 0 (r = 0.927; P < 0.0001). There was a moderate correlation between the number of high-signal DWI lesions and the plaque volume of HU 0-60 (r = 0.568; P = 0.0099) and the sum total of HU < 0 and HU 0-60 (r = 0.609; P = 0.0047). Quantitative and qualitative tissue characterization of carotid plaques using MDCT might be a useful predictor for silent ischemic lesions after CAS. (orig.)

  4. SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY STUDY OF REGIONAL CEREBRAL BLOOD FLOW IN PATIENTS WITH HEMISPATIAL NEGLECT

    Institute of Scientific and Technical Information of China (English)

    尹雅芙; 任艳; 李亚明

    2003-01-01

    Objective.To explore the correlations between the occurrence and severity of neglect and the region,range or extent of the decrease in regional cerebral blood flow(rCBF). Methods. Nineteen dextromanual patients who were diagnosed as unilateral stroke clinically and hemispatial neglect by a neglect test battery received single photon emission computed tomography(SPECT) scans. Results. On images,the damages of patients with neglect were seen most frequently in the frontal cortex,and then in turn in the parietal cortex,occipital cortex,temporal cortex,basal ganglia and thalamus. Most patients with neglect had two or more regions damaged. The most significant region was temporal-parietal-occipi-tal(TPO)junction. The correlation coefficient between rCBF and the severity of neglect was -0.34(t=-1.5,P>0.05),and that between the decrease percentage of rCBF and the severity of neglect was 0.34(t=1.47,P>0.05). The correlation coefficients between the range,number of foci,the flow deficit size and the severity of neglect were 0.71(t=4.13,P<0.01),0.70(t=4.07,P<0.01)and 0.64(t=3.40, P<0.01),respectively. Conclusions. The severity of neglect correlates with rCBF and the decrease percentage of rCBF insignificantly,but correlates positively with the range,number of foci and the flow deficit size significantly. Hemispatial neglect is caused by the damage of multiple sites and combined damage results in more severe neglect.

  5. Interventional model establishment and computed tomography perfusion imaging for early diagnosis of acute cerebral infarction in dogs

    International Nuclear Information System (INIS)

    Objective: To establish interventionally a new canine model of focal cerebral infarction suitable to the study of imaging diagnosis and thrombolytic therapy, and to evaluate the application of computed tomography perfusion (CTP) in super acute ischemic cerebrovascular disease. Methods: Ten beagle adult dogs with self white thrombi of venous blood, injected into the left internal carotid arteries through 4F headhunter catheter selectively were created under fluoroscopic guidance. The cerebral angiography was performed before and after the embolization and the patency of the occluded cerebral arteries was observed with angiography at 1, 2 and 5 hours after the procedure. The CTP was performed at 2 hours after embolization. These dogs were sacrificed and their cerebra were taken out for pathologic study at 24th hour. Results: The occlusions of middle cerebral artery were shown angiographically in all 10 dogs with additional other cerebral arteries occlusion in 4. All occluded arteries were not recanalized at 2 hours after embolization, but the occluded arteries of 2 canines were partly recanalized at 5 hours. The regional cerebral blood flow (rCBF) was decreased to 48.3% ± 13.2% (33.7%-69.2%) in CTP of 9 canines showing no significant difference between digital subtraction angiography (DSA) and CTP (P>0.05). All dogs were survived at 24 hours without any severe complications. The cerebral infarction was found in deep part of cerebrum of all dogs. Conclusions: The establishment of acute cerebral infarction model in dogs with interventional technique is simple, micro invasive and reliable, for investigating CTP as a fast, accurate and no invasive method in evaluating the canine super acute ischemic cerebrovascular disease. (authors)

  6. Cerebral perfusion inhomogeneities in schizophrenia demonstrated with single photon emission computed tomography and Tc99m-hexamethylpropyleneamineoxim

    International Nuclear Information System (INIS)

    Cerebral blood flow was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim (HMPAO) and single photon emission computed tomography (SPECT) in 28 female schizophrenic patients (20 acute and 8 chronic) classified according to DSM-III. Eleven normals served as controls. The acute patients were classified according to positive and negative symptoms. Patients with predominantly positive symptoms showed by and large normal and homogeneous cerebral isotope uptake. Those with negative symptoms, and the chronic patients, showed inhomogeneous tracer uptake with multiple regions of hypoperfusion in slices 4-6 cm above the orbitomeatal line. The findings support in principle the notion that schizophrenia with negative or chronic symptoms does not affect the whole brain homogeneously. Brain imaging with Tc99m-HMPAO and SPECT might be used to distinguish various types of schizophrenia. (author)

  7. Effect of isovolemic, isothermic hemodialysis on cerebral perfusion and vascular stiffness using contrast computed tomography and pulse wave velocity.

    Directory of Open Access Journals (Sweden)

    Ansgar Reising

    Full Text Available BACKGROUND: Patients undergoing hemodialysis treatment have a six-fold increased risk for stroke relative to the general population. However, the effect of hemodialysis on cerebral blood flow is poorly studied and confounding factors like blood pressure and ultrafiltration as well as temperature changes have rarely been accounted for. The aim of our study was to use state-of-the-art technology to evaluate the effect of a single dialysis session on cerebral perfusion as well as on vascular stiffness. METHODS: Chronic hemodialysis patients (7 male/3 female, mean age 58 years were recruited. Cerebral blood flow and arterial pulse wave velocity were measured before and immediately after a hemodialysis session. To exclude effects of volume changes we kept ultrafiltration to a minimum, allowing no change in body weight. Isothermic conditions were maintained by using the GENIUS single-pass batch-dialysis system with a high-flux polysulfone dialyser. Cerebral blood flow was measured by contrast-enhanced computed tomography. Pulse wave velocity was measured using the SphygmoCor (AtCor Medical, USA device by a single operator. RESULTS: This study shows for the first time that isovolemic, isothermic hemodialysis neither affected blood pressure or heart rate, nor total or regional cerebral perfusion. There was also no change in pulse wave velocity. CONCLUSIONS: Mechanisms other than the dialysis procedure itself might be causative for the high incidence of ischemic strokes in this patient population. Moreover, the sole removal of uremic toxins does not lead to short-term effects on vascular stiffness, underlying the importance of volume control in this patient population.

  8. Hematoma intraparenquimatoso cerebral espontâneo: aspectos à tomografia computadorizada Spontaneous cerebral intraparenchymatous hematoma: computed tomography findings

    OpenAIRE

    Celso Monteiro Soares; Antonio Carlos Pires Carvalho

    2005-01-01

    OBJETIVO: Identificar os aspectos mais freqüentes do hematoma intraparenquimatoso cerebral espontâneo observados na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram analisados, retrospectivamente, os exames de tomografia computadorizada de 250 pacientes com hematoma intraparenquimatoso cerebral espontâneo, provenientes de três diferentes hospitais da cidade do Rio de Janeiro. RESULTADOS: O hematoma intraparenquimatoso cerebral profundo foi o de maior incidência, equivalendo a 54,4% (136...

  9. Single photon emission computed tomography (SPECT): Clinical routine diagnosis of cerebral malfunction

    International Nuclear Information System (INIS)

    Positron emission tomography is the gold standard for in vivo research in neurophysiology and pathology. The introduction of SPECT and the development of such tracers as 99mTc-HMPAYO (99mTc-d,l-hexamethylpropylenaminoxim) and, more recently, 123I-iomazenil and 123I-IBZM (123I-3-iodo-6-methoxybenzamide) allowed closer examination of the perfusion of the brain and neuroreceptor density mapping in more than the few institutions that can afford PET and the production of special tracers marked with a positron emitting nucleus. Nuclear medicine's future will be based on neuroreceptor density mapping, as further tracers will become commercially available and no other technique can probably show such low concentrations of the receptors. Probably MR techniques will be used for brain's perfusion measurement in future. For examination of a limited cerebral region xenon-enhanced CT is an alternative to perfusion measurements with HMPAO, or a very interesting supplement. Of the old techniques in nuclear medicine, examination of the liquor dynamics is still feasible and well supplemented by SPECT. (orig./MG)

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses What is CT (Computed Tomography) of ... of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  11. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  13. Cerebral complications of irradiation and Methotrexate application in lymphatic leukemias as revealed by computer tomography

    International Nuclear Information System (INIS)

    Eighteen children were examined whose skull had previously been irradiated. The total focal dose ranged between 15 to 30 Gy. Methotrexate was administered intraspinally, in most cases 7.5 mg twice weekly. The total dose ranged between 60 to 158.5 mg MTX. The patients were examined using computed tomography 8 to 46 months from the onset of disease. The most frequent symptoms of the effects of irradiation were cortisubcortical atrophy, then various manifestations of leukoencephalopathy which, if treatment is not discontinued leads to necrotic changes in the white matter of the hemispheres

  14. Abnormalities in rCBF [regional cerebral blood flow] and computed tomography in patients with Alzheimer's disease and in controls

    International Nuclear Information System (INIS)

    The pattern of abnormal distribution of single photon emission computed tomography (SPECT) cerebral blood flow tracer 99m-technetium-hexamethylpropyleneamine oxime (99Tcm-HMPAO) was investigated in 14 patients with clinically diagnosed Alzheimer's disease (AD) who subsequently had post-mortem confirmation, and also in 14 elderly control subjects. These abnormalities were compared with computed tomography (CT) scans to investigate the degree to which the focal SPECT deficits were due to atrophy. Results show that SPECT imaging with 99Tcm-HMPAO and CT scanning both have a higher incidence of abnormality in AD patients than in controls and that the difference between patients and controls is greater with SPECT than with CT. Frontal SPECT and CT abnormalities in moderate/severe Alzheimer's disease occur as frequently as temporal/occipital abnormalities but the latter are rare in control subjects. Around 50% of SPECT deficits occur in CT normal brain regions, showing that atrophy is not the sole cause of SPECT deficits. (author)

  15. Comparison of Two Algorithms for Analysis of Perfusion Computed Tomography Data for Evaluation of Cerebral Microcirculation in Chronic Subdural Hematoma.

    Science.gov (United States)

    Trofimov, Alexey O; Kalentiev, George; Voennov, Oleg; Yuriev, Michail; Agarkova, Darya; Trofimova, Svetlana; Bragin, Denis E

    2016-01-01

    The aim of this work was comparison of two algorithms of perfusion computed tomography (PCT) data analysis for evaluation of cerebral microcirculation in the perifocal zone of chronic subdural hematoma (CSDH). Twenty patients with CSDH after polytrauma were included in the study. The same PCT data were assessed quantitatively in cortical brain region beneath the CSDH (zone 1), and in the corresponding contralateral brain hemisphere (zone 2) without and with the use of perfusion calculation mode excluding vascular pixel 'Remote Vessels' (RV); 1st and 2nd analysis method, respectively. Comparison with normal values for perfusion indices in the zone 1 in the 1st analysis method showed a significant (p < 0.01) increase in CBV and CBF, and no significant increase in MTT and TTP. Use of the RV mode (2nd analysis method) showed no statistically reliable change of perfusion parameters in the microcirculatory blood flow of the 2nd zone. Maintenance of microcirculatory blood flow perfusion reflects the preservation of cerebral blood flow autoregulation in patients with CSDH. PMID:27526170

  16. Sensitivity of visual and quantitative detection of middle cerebral artery occlusion on non-contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    This study aims to investigate diagnostic sensitivity and reliability for the detection of middle cerebral artery occlusion (MCAO) on non-contrast-enhanced computed tomography (NECT) by visual assessment (VA), Hounsfield unit (HU) measurement, calculation of the Hounsfield unit/hematocrit (HU/Hct) ratio, and combination of visual assessment and attenuation measurement (VA + HU). NECT of 18 patients with angiographically proven MCAO and 18 patients without MCAO were reviewed by two blinded observers. Visual assessment of presence or absence of a hyperdense sign was followed by HU measurement of both middle cerebral arteries (MCA). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for VA, HU measurement, HU/Hct ratio, and VA + HU measurement. Receiver operating characteristic curve analysis (ROC) was performed to determine the optimal cut-off values for MCAO using attenuation measurements or HU/Hct ratio. Diagnostic sensitivity/specificity was 63 %/91 % for VA, 56 %/88 % for attenuation measurement, 68 %/81 % for HU/Hct ratio, and 75 %/78 % for VA + HU. ROC curve analysis revealed cut-off values of >42.5 HU for attenuation measurements and >1.12 HU/Hct for HU/Hct ratio. Combination of visual assessment with additional attenuation measurement with a cut-off value of 42.5 HU is recommended for most sensitive and reliable detection of MCAO on NECT. (orig.)

  17. Sensitivity of visual and quantitative detection of middle cerebral artery occlusion on non-contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, M.; Buhk, J.H.; Kemmling, A.; Fiehler, J.; Groth, M. [University Medical Center Hamburg-Eppendorf, Center for Radiology and Endoscopy Department of Diagnostic and Interventional Neuroradiology, Hamburg (Germany); Romero, J.M. [Massachusetts General Hospital Harvard Medical School, Department of Radiology Division of Neuroradiology, Boston, MA (United States)

    2014-12-15

    This study aims to investigate diagnostic sensitivity and reliability for the detection of middle cerebral artery occlusion (MCAO) on non-contrast-enhanced computed tomography (NECT) by visual assessment (VA), Hounsfield unit (HU) measurement, calculation of the Hounsfield unit/hematocrit (HU/Hct) ratio, and combination of visual assessment and attenuation measurement (VA + HU). NECT of 18 patients with angiographically proven MCAO and 18 patients without MCAO were reviewed by two blinded observers. Visual assessment of presence or absence of a hyperdense sign was followed by HU measurement of both middle cerebral arteries (MCA). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for VA, HU measurement, HU/Hct ratio, and VA + HU measurement. Receiver operating characteristic curve analysis (ROC) was performed to determine the optimal cut-off values for MCAO using attenuation measurements or HU/Hct ratio. Diagnostic sensitivity/specificity was 63 %/91 % for VA, 56 %/88 % for attenuation measurement, 68 %/81 % for HU/Hct ratio, and 75 %/78 % for VA + HU. ROC curve analysis revealed cut-off values of >42.5 HU for attenuation measurements and >1.12 HU/Hct for HU/Hct ratio. Combination of visual assessment with additional attenuation measurement with a cut-off value of 42.5 HU is recommended for most sensitive and reliable detection of MCAO on NECT. (orig.)

  18. Regional cerebral blood flow in patients with sickle cell disease: study with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Neurological complications have been reported in patients with sickle-cell disease (SCD) using positron emission tomography (PET), magnetic resonance imaging (MRI), and computed tomography (CT), but not with single photon emission computed tomography (SPECT). The objective of this study was to investigate brain perfusion in the patients with SCD using SPECT after technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO), was administered and compare the findings with those of demography, physical examination, MRI and hematological profile. The study involved 21 patients (12 males, 9 females, age at study 8-45 years) who were known to be having SCD for a duration of at least 5 years. The patients were not in acute crisis and had normal neurological assessments with no known history of stroke or transient ischemic episode or previous abnormal CT or MRI brain scan, and were right-handed. The brain SPECT was performed after intravenous injection of 740 MBq (20 mCi) 99mTc-HMPAO in adults or an appropriate dose in pediatric patients. The scans were visually interpreted by two nuclear medicine physicians and a decision was reached by consensus. An MRI done 3 months later was interpreted by a radiologist. The demographic data and hematological profile were obtained from the medical records of the patients. Of the 21 patients, 7 (age 11-22 years) had brain perfusion deficit mostly in the frontal lobe either alone or in combination with temporal and/or parietal lobe. The MRI was abnormal in 2 patients. The brain perfusion deficit was not associated with the demographic data of the patients or hematological profiles. The findings show that SPECT was useful in detecting brain perfusion deficit in SCD patients, and such an early detection may be clinically useful in the subsequent follow-up of such patients, since it is known that cerebral perfusion deficit can lead to silent infarct and/or overt stroke, and affect cognitive skills. (author)

  19. Intracranial germ cell tumors with special emphasis on computed tomography and cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Tomohiro; Miyasaka, Kazuo; Abe, Satoru; Takei, Hidetoshi; Aida, Toshimitsu; Abe, Hiroshi; Tsuru, Mitsuo (Hokkaido Univ., Sapporo (Japan). School of Medicine)

    1984-10-01

    Germ cell tumors have been classified into germinoma, embryonal carcinoma, choriocarcinoma and teratoma by a World Health Organization proposal, although this subgrouping is still controversial. This paper reviews clinical, computed tomographic (CT) and angiographic data of 14 patients with histologically verified germ cell tumors. These 13 males and one female, ranging from 5 to 34 years in age, included 6 cases of teratoma, 5 of germinoma and 3 of embryonal carcinoma. On plain CT, perifocal edema was never seen in cases with teratoma or germinoma, but was usual in those with embryonal carcinoma. Teratoma, although often containing calcium deposits, was isodense in most parts of the mass, while germinoma was always hyperdense in the solid part. CT with intravenous iodine demonstrated some enhancing effect within the tumor mass in all cases, but it differed in intensity from one group to another. Enhancement was less intense or slight in germinoma, whereas it was marked in all of embryonal carcinoma and most of teratoma. Cerebral angiography showed abnormal tumor vessels and dense tumor stain in embryonal carcinoma, but these were not observed in teratoma and faintly in rare occasions of germinoma.

  20. Cerebral damage following ventricular shunt for infantile hydrocephalus evaluated by computed tomography

    International Nuclear Information System (INIS)

    The results of a late CT control of infantile hydrocephalus is reported with an analysis of effects of the catheter on the cerebral tissue in the immediate and late postoperative course. The most frequent finding is blood in the ventricle and/or subependymal or intraparenchymal along the catheter or near its tip. (orig.)

  1. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  2. Sensitivity of 3D Gradient Recalled Echo Susceptibility-Weighted Imaging Technique Compared to Computed Tomography Angiography for Detection of Middle Cerebral Artery Thrombus in Acute Stroke

    OpenAIRE

    Amit Agarwal; Kanupriya Vijay; Krishnamoorthy Thamburaj; Sangam Kanekar; Paul Kalapos

    2014-01-01

    We aimed at comparing the sensitivity of magnetic resonance (MR) susceptibility-weighted imaging (SWI) with computed tomography angiography (CTA) in the detection of middle cerebral artery (MCA) thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI) and CTA...

  3. Perfusion computed tomography of intracranial meningiomas: In vivo correlation of cerebral blood volume and vascular permeability

    Science.gov (United States)

    Granata, Francesca; Morabito, Rosa; Alafaci, Concetta; Barresi, Valeria; Tomasello, Francesco; Vinci, Sergio; Calamuneri, Alessandro; Grasso, Giovanni; Salpietro, Francesco Maria; Longo, Marcello

    2015-01-01

    Background A noninvasive method to predict the grade of a meningioma would be desirable since it would anticipate information about tumour nature, recurrence and improve tumour management and outcomes. The aim of the present study was to assess the ability of perfusion computed tomography (PCT) technique in predicting the meningioma grade before surgery. Data from PCT, such as cerebral blood volume (CBV) and permeability surface (PS), were correlated with immunohistolopathological information. Methods Twenty-three patients with a diagnosis of intracranial meningioma underwent PCT for pre-surgical evaluation of CBV and PS. During surgery, samples from the centre and periphery of the tumour were obtained. Two correspondent regions of interest (ROIs) were drawn on CBV and PS maps. Central and peripheral CBV and PS mean values were calculated. PCT parameters were correlated to CD-34 and endoglin. Results There was a positive correlation between PS and CD-34. No correlation was found between PS values and endoglin, CBV values and CD-34 and endoglin values. Conclusion Our findings suggest that PCT may support conventional morphological imaging in predicting meningioma grading before surgery. PMID:26246100

  4. Evaluation of post-mortem lateral cerebral ventricle changes using sequential scans during post-mortem computed tomography.

    Science.gov (United States)

    Hasegawa, Iwao; Shimizu, Akinobu; Saito, Atsushi; Suzuki, Hideto; Vogel, Hermann; Püschel, Klaus; Heinemann, Axel

    2016-09-01

    In the present study, we evaluated post-mortem lateral cerebral ventricle (LCV) changes using computed tomography (CT). Subsequent periodical CT scans termed "sequential scans" were obtained for three cadavers. The first scan was performed immediately after the body was transferred from the emergency room to the institute of legal medicine. Sequential scans were obtained and evaluated for 24 h at maximum. The time of death had been determined in the emergency room. The sequential scans enabled us to observe periodical post-mortem changes in CT images. The series of continuous LCV images obtained up to 24 h (two cases)/16 h (1 case) after death was evaluated. The average Hounsfield units (HU) within the LCVs progressively increased, and LCV volume progressively decreased over time. The HU in the cerebrospinal fluid (CSF) increased at an individual rate proportional to the post-mortem interval (PMI). Thus, an early longitudinal radiodensity change in the CSF could be potential indicator of post-mortem interval (PMI). Sequential imaging scans reveal post-mortem changes in the CSF space which may reflect post-mortem brain alterations. Further studies are needed to evaluate the proposed CSF change markers in correlation with other validated PMI indicators. PMID:27048214

  5. The feasibility and clinical application of flat-panel detector computer tomography in evaluating cerebral blood volume: an initial prospective study

    International Nuclear Information System (INIS)

    Objective: To investigate the feasibility and clinical value of the determination of cerebral blood volume (CBV) map by using flat-panel detector computer tomography (FDCT) angiography system. Methods: A prospective self-control clinical trial was conducted in 20 patients with cerebral ischemia who were encountered during the period from June 2010 to March 2011. All the patients were diagnosed as cerebral ischemic diseases and were scheduled to take interventional procedures. All patients underwent cerebral perfusion computer tomography (PCT) and CBV map exam which was performed by flat-panel detector computer tomography (FDCT-CBV). The CBV values obtained by the two exam types were analyzed and compared with each other by using statistic methods. Results: All PCT and FDCT-CBV exams were successfully accomplished in all the twenty patients. A significant correlation existed between the CBV images and CBV values obtained by the two exam types. The correlation coefficient was 0.68 (P<0.01). The Bland-Altman analysis showed a mean difference of -0.25±2.79 between FDCT-CBV and PCT-CBV, indicating that FDCT-CBV values were only slightly lower than those of PCT-CBV. Conclusion: CBV exam by using flat-panel detector angiography system is clinically feasible and the results of FDCT-CBV is comparable to those of PCT-CBV. As the FDCT-CBV can offer functional images of the whole brain within the catheter lab, this technique is very helpful in making the reasonable operation plan and in improving the safety of endovascular procedures in neurosurgery. (authors)

  6. Regional cerebral blood flow measurement using N-isopropyl-p-[123I] iodoamphetamine and rotating gamma camera emission computed tomography

    International Nuclear Information System (INIS)

    Thirty-one regional cerebral blood flow (rCBF) measurements were performed on 26 patients with cerebrovascular accidents using N-Isopropyl-p-[123I] Iodoamphetamine (123I-IMP) and rotating gamma camera emission computed tomography (ECT). The equation for determining rCBF is as follows: F=100.R.Cb/(N.A), where F is rCBF in ml/100 g/min., R is the constant withdrawal rate of arterial blood in ml/min., Cb is the brain activity concentration in μCi/g, A is the total activity (5 min.) in the withdrawal arterial whole blood in μCi and N is the fraction of A that is true tracer activity (0.75). In determining Cb at 5 min. after injection, reconstructed counts from 35 min. to 59 min. were corrected to represent those from 4 min. to 5 min. with the use of time activity curve for the entire brain immediately after injection to 30 min. Reconstructed counts of central region in tomographic image were corrected 118% of the obtained values from the result of the countingrate ratio between peripheral and central regions of interests obtained from phantom study. Brain mean blood flow values were distributed from 11 to 39 ml/100 g/min. In 119 cortical regions obtained from 11 measurements in 9 patients, there was a significant correlation (r=0.41, p123I-IMP and rotating gamma camera ECT and those from 133Xe inhalation method. rCBF measurement using 123I-IMP and rotating gamma camera ECT is not only relatively noninvasive measurement for the entire brain but also three-dimensional evaluation. Besides, it is superior in spatial resolution and accuracy to conventional 133Xe clearance method. (author)

  7. Cerebral blood flow velocities after subarachnoid haemorrhage in relation to the amount of blood clots in the initial computed tomography

    International Nuclear Information System (INIS)

    In 72 patients with acute subarachnoid haemorrhage (SAH) the relationship between the amount of subarachnoid blood clots detected by initial cranial computed tomography (CCT) up to 48 hours after bleeding and the later development of vasospasm, established by blood flow velocity measurement with transcranial Doppler ultrasound (TCD) was investigated. The serial Doppler examinations started within the first 72 hours after SAH and were carried out every second day up to three weeks. Each Doppler recording was accompanied by a neurological examination. Patients classified as Hunt and Hess grade V were excluded from the study. All patients with remarkable brain oedema in CCT or with intracranial pressure above 25 mmHg were also excluded. Because of the well known agedependence of vasospasm after SAH, two age groups were formed. A statistically significant correlation (p > 0.05) between blood flow velocities and blood load after SAH was not found. The mean age of the investigated 72 individuals was 48.9 years (14 up to 76 years). 47 patients were younger than 56 years. Linear regression analysis indicated a correlation with a quite low significance level (r = 0.350, p 0.05) between these two variables could be established in the 25 patients older than 55 years. In a second step an intra-individual comparison of side-to-side differences in TCD and CCT was made. There were no significant differences in blood flow velocities between subjects with or without side-to-side differences in cisternal blood load. It is concluded that the amount of blood visible on initial CCT after SAH is not a powerful predictor of cerebral blood flow velocities measured by TCD. (author)

  8. Measurements of regional cerebral blood flow (rCBF) using dynamic single-photon emission computed tomography (DSPECT): Definition of a generally acceptable normal range and follow-up checks after extracranial bypass surgery

    International Nuclear Information System (INIS)

    The usefulness of dynamic single-photon emission computed tomography was evaluated in 50 volunteers with unobtrusive cerebral findings, who were to provide the relevant standard values. It was found that the values measured were easily reproducible. Measurements in patients showing cerebrovascular disease that were carried out before and after extracranial bypass surgery did mostly not suggest any perceivable improvement of cerebral blood flow. In isolated cases the cerebral reserve was influenced favourably, as judged from measurements after administration of acetazolamide. (MBC)

  9. The role of additional computed tomography in the decision-making process on the secondary prevention in patients after systemic cerebral thrombolysis

    Directory of Open Access Journals (Sweden)

    Sobolewski P

    2015-12-01

    Full Text Available Piotr Sobolewski,1 Grzegorz Kozera,2 Wiktor Szczuchniak,1 Walenty M Nyka2 1Department of Neurology and Stroke, Unit of Holy Spirit Specialist Hospital in Sandomierz, Sandomierz, Poland; 2Department of Neurology, Medical University of Gdańsk, Gdańsk, Poland Introduction: Patients with ischemic stroke undergoing intravenous (iv-thrombolysis are routinely controlled with computed tomography on the second day to assess stroke evolution and hemorrhagic transformation (HT. However, the benefits of an additional computed tomography (aCT performed over the next days after iv-thrombolysis have not been determined.Methods: We retrospectively screened 287 Caucasian patients with ischemic stroke who were consecutively treated with iv-thrombolysis from 2008 to 2012. The results of computed tomography performed on the second (control computed tomography and seventh (aCT day after iv-thrombolysis were compared in 274 patients (95.5%; 13 subjects (4.5%, who died before the seventh day from admission were excluded from the analysis.Results: aCTs revealed a higher incidence of HT than control computed tomographies (14.2% vs 6.6%; P=0.003. Patients with HT in aCT showed higher median of National Institutes of Health Stroke Scale score on admission than those without HT (13.0 vs 10.0; P=0.01 and higher presence of ischemic changes >1/3 middle cerebral artery territory (66.7% vs 35.2%; P<0.01. Correlations between presence of HT in aCT and National Institutes of Health Stroke Scale score on admission (rpbi 0.15; P<0.01, and the ischemic changes >1/3 middle cerebral artery (phi=0.03 existed, and the presence of HT in aCT was associated with 3-month mortality (phi=0.03.Conclusion: aCT after iv-thrombolysis enables higher detection of HT, which is related to higher 3-month mortality. Thus, patients with severe middle cerebral artery infarction may benefit from aCT in the decision-making process on the secondary prophylaxis. Keywords: ischemic stroke, iv

  10. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Marlies, E-mail: marlies.wagner@kgu.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com [Siemens AG, Health Care Sector (Germany); Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Singer, Oliver C., E-mail: o.singer@em.uni-frankfurt.de [Hospital of Goethe University, Department of Neurology (Germany); Berkefeld, Joachim, E-mail: berkefeld@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany)

    2013-08-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.

  11. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    International Nuclear Information System (INIS)

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy

  12. Measurement of cerebral blood flow with 133Xe inhalation and dynamic single photon emission computer tomography. Normal values

    International Nuclear Information System (INIS)

    Cerebral blood flow was studied by 133Xe inhalation tomography in 25 healthy subjects. Mean age was 41 years and range 23-66 years. Mean hemispheric CBF at rest was 59.8 ml/100 g/min, and cerebellar flow 60.8 ml/100 g/min. The distribution of CBF values was skewed and approximated a log normal distribution. Estimated lower and upper normal reference range limits calculated as mean (log) = - 2 S.D. (log) were 47-74 ml/100 g/min. Women had approximately 5 ml/100 g/min higher CBF values than men, corresponding to the difference in hematocrit. Neither in men or women was there any tendency to age dependent reduction or increase in flow. In both sexes hemispheric regional CBF (rCBF) was asymmetric with higher flow values in the right cerebral hemisphere; particularly in the anterior distribution territory of the middle cerebral artery. Emotional activation as a consequence of the study conditions is assumed to be the cause of this observed asymmetry. Cerebellar flow was not assymetric. No significant difference in cerebellar or hemispheric CBF was found when a second study followed the first by 3-15 months, PCO2 correction of flow improved reproducibility. Acetazolamide responses are reported. (author)

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head What is CT Scanning of the ... Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  15. Computed tomography in severe protein energy malnutrition.

    OpenAIRE

    Househam, K C; Villiers, J.F.

    1987-01-01

    Computed tomography of the brain was performed on eight children aged 1 to 4 years with severe protein energy malnutrition. Clinical features typical of kwashiorkor were present in all the children studied. Severe cerebral atrophy or brain shrinkage according to standard radiological criteria was present in every case. The findings of this study suggest considerable cerebral insult associated with severe protein energy malnutrition.

  16. Epileptic patterns of local cerebral metabolism and perfusion in man determined by emission computed tomography of 18FDG and 13NH3

    International Nuclear Information System (INIS)

    Seventeen patients with partial epilepsy had EEG monitoring concurrent with cerebral emission computed tomography (ECT) after 18F-fluorodeoxyglucose (18FDG) and 13N-ammonia were given intravenously as indicators of local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. In 12 of 15 patients who had unilateral or focal electrical abnormalities, interictal 18FDG scan patterns clearly showed localized regions of decreased (20% to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization. These hypometabolic zones appeared normal on x-ray computed tomography in all but three patients and were unchanged on scans repeated on different days. In 5 of 6 patients who underwent temporal lobectomy, the interictal 18FDG scan correctly detected the pathologically confirmed lesion as a hypometabolic zone, and removal of the lesion site resulted in marked clinical improvement. In contrast, the ictal 18FDG scan patterns clearly showed foci of increased (82% to 130%) LCMR/sub glc/, which correlated temporally and anatomically with ictal EEG spike foci and were within the zones of interictal hypometabolism (3 studies in 2 patients). 13NH3 distributions paralleled 18FDG increases and decreases in abnormal zones, but 13NH3 differences were of lesser magnitude. When the relationship of 13NH3 uptake to local blood flow found in dog brain was applied as a correction to the patients' 13NH3 scan data, local alterations in perfusion and glucose utilization were usually matched, both in the interictal and ictal states

  17. Cranial computed tomography in paediatrics

    International Nuclear Information System (INIS)

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect probable therapeutic consequences and expected diagnostic yield. In view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy. (Author)

  18. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Tsuzura, Shigenobu [Metropolitan Medical Center of the Severely Handicapped, Fuchu, Tokyo (Japan); Matsuda, Hiroshi

    1995-07-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]-iodoamphetamine ({sup 123}I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author).

  19. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    International Nuclear Information System (INIS)

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author)

  20. Regional cerebral blood flow changes in schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I]iodoamphetamine (IMP)

    International Nuclear Information System (INIS)

    Regional cerebral blood flows (rCBF) were measured in patients with schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I]iodoamphetamine (IMP). The subjects were 20 patients with shizophrenia, 32 patients with endogenous depression and 20 normal controls. The patients with depression were divided into 3 groups; unmedicated, medicated patients in depressive state, and medicated patients in remited state. The rCBF were calculated by the corticocerebellar ratio (CCR), which was expressed as a ratio of activity per pixel in cortical regions of interest to the activity per pixel in the cerebellum. The results were as follows. In patients with schizophrenia the marked decrease in rCBF in bilateral frontal regions and the lower rCBF in the left than in the right hemisphere were observed. There was no significant correlation between the mean rCBF and BPRS (Brief Psychiatric Rating Scale) in patients with shizophrenia. In patients with depression the decrease in rCBF in overall cerebral regions and the lower rCBF in the left than in the right hemisphere were observed in both groups in depressive state. These changes were normalized in remited state, though there was no significant difference in rCBF between on medication and off medication. There was significantly negative correlation between the mean rCBF and Hamilton Depression Rating Scale in patients with depression. These results support the previously reported 'hypofrontality' and the left hemispheric dysfunction in shizophrenia. In depressive patients the overall cerebral dysfunction was revealed more remarkablly in the left than in the right hemisphere, which was normalized following the improvement of depressive symptoms. Furthermore, it was suggested that the applications of IMP-SPECT could be useful for the diagnosis and research for the cerebral function in mental illness. (author) 59 refs

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses What is CT (Computed Tomography) of the Sinuses? What are ...

  2. Absolute quantification of cerebral blood flow in neurologically normal volunteers: dynamic-susceptibility contrast MRI-perfusion compared with computed tomography (CT)-perfusion.

    Science.gov (United States)

    Ziegelitz, Doerthe; Starck, Göran; Mikkelsen, Irene K; Tullberg, Mats; Edsbagge, Mikael; Wikkelsö, Carsten; Forssell-Aronson, Eva; Holtås, Stig; Knutsson, Linda

    2009-07-01

    To improve the reproducibility of arterial input function (AIF) registration and absolute cerebral blood flow (CBF) quantification in dynamic-susceptibility MRI-perfusion (MRP) at 1.5T, we rescaled the AIF by use of a venous output function (VOF). We compared CBF estimates of 20 healthy, elderly volunteers, obtained by computed tomography (CT)-perfusion (CTP) and MRP on two consecutive days. MRP, calculated without the AIF correction, did not result in any significant correlation with CTP. The rescaled MRP showed fair to moderate correlation with CTP for the central gray matter (GM) and the whole brain. Our results indicate that the method used for correction of partial volume effects (PVEs) improves MRP experiments by reducing AIF-introduced variance at 1.5T. PMID:19253361

  3. Epileptic patterns of local cerebral metabolism and perfusion in man determined by emission computed tomography of /sup 18/FDG and /sup 13/NH/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.; Engel, J. Jr.; Phelps, M.E.; Selin, C.

    1979-01-01

    Seventeen patients with partial epilepsy had EEG monitoring concurrent with cerebral emission computed tomography (ECT) after /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-ammonia were given intravenously as indicators of local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. In 12 of 15 patients who had unilateral or focal electrical abnormalities, interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20% to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization. These hypometabolic zones appeared normal on x-ray computed tomography in all but three patients and were unchanged on scans repeated on different days. In 5 of 6 patients who underwent temporal lobectomy, the interictal /sup 18/FDG scan correctly detected the pathologically confirmed lesion as a hypometabolic zone, and removal of the lesion site resulted in marked clinical improvement. In contrast, the ictal /sup 18/FDG scan patterns clearly showed foci of increased (82% to 130%) LCMR/sub glc/, which correlated temporally and anatomically with ictal EEG spike foci and were within the zones of interictal hypometabolism (3 studies in 2 patients). /sup 13/NH/sub 3/ distributions paralleled /sup 18/FDG increases and decreases in abnormal zones, but /sup 13/NH/sub 3/ differences were of lesser magnitude. When the relationship of /sup 13/NH/sub 3/ uptake to local blood flow found in dog brain was applied as a correction to the patients' /sup 13/NH/sub 3/ scan data, local alterations in perfusion and glucose utilization were usually matched, both in the interictal and ictal states.

  4. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-123I IMP single photon emission computed tomography

    International Nuclear Information System (INIS)

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (Vd) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP (123I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the 123I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, pd was also significantly decreased in the pons (pd for the pons and age at onset (r=0.59, pd in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, pd obtained by 123I-IMP SPECT for patients with MJD identified by gene analysis. Our study shows that SPECT measurement of rCBF and Vd is useful for understanding the pathophysiology of MJD. (author)

  5. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  6. Multi-slice Computed Tomography Angiography in the Detection of Residual or Recurrent Cerebral Aneurysms after Surgical Clipping

    International Nuclear Information System (INIS)

    Purpose: To assess the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography compared to digital subtraction angiography (DSA) in detecting residual or recurrent aneurysms in patients undergoing aneurysm clipping surgery. Material and Methods: Eight patients with nine aneurysms who had both MSCTA and DSA were included in the study. Two independent experienced neuroradiologists evaluated the examinations. Results: Accuracy, sensitivity, and specificity of detecting residual or recurrent aneurysms on MSCTA were 0.80, 0.60, and 1.00, respectively. Positive and negative predictive values were 1.00 and 0.71, respectively. Conclusion: MSCTA is a promising technique for evaluating residual or recurrent aneurysms in patients undergoing surgical treatment of aneurysm with titanium clips

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Videos related to Computed Tomography (CT) - Head About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Images related to Computed Tomography (CT) - Sinuses About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  11. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S;

    1983-01-01

    Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used...... sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow....

  12. Cervical computed tomography

    International Nuclear Information System (INIS)

    This book describes the possibilities of cervical computed tomography with the apparatus available at present. The normal anatomy of the cervical region as it appears in computed tomography is described with special regard to its compartimental structure and functional aspects; this is supplemented by anatomically normal measures obtained from cervical computed tomograms of 60 healthy individuals of different age and both sexes. The morphology of cervical anomalies obtained via CT and of the various acquired cervical disease processes is discussed and illustrated by means of the authors' own observations; the diagnostic value of the findings obtained by CT is discussed, a diagnosis is set up. (orig./MG)

  13. Human cerebral circulation. Positron emission tomography studies

    International Nuclear Information System (INIS)

    We reviewed the literature on human cerebral circulation and oxygen metabolism, as measured by positron emission tomography (PET), with respect to normal values and of regulation of cerebral circulation. A multicenter study in Japan showed that between-center variations in cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) values were not considerably larger than the corresponding within-center variations. Overall mean±SD values in cerebral cortical regions of normal human subjects were as follows: CBF=44.4±6.5 ml/100 ml/min; CBV=3.8±0.7 ml/100 ml; OEF=0.44±0.06; CMRO2=3.3±0.5 ml/100 ml/min (11 PET centers, 70 subjects). Intrinsic regulation of cerebral circulation involves several factors. Autoregulation maintains CBF in response to changes in cerebral perfusion pressure; chemical factors such as PaCO2 affect cerebral vascular tone and alter CBF; changes in neural activity cause changes in cerebral energy metabolism and CBF; neurogenic control of CBF occurs by sympathetic innervation. Regional differences in vascular response to changes in PaCO2 have been reported, indicating regional differences in cerebral vascular tone. Relations between CBF and CBV during changes in PaCO2 and during changes in neural activity were in good agreement with Poiseuille's law. The mechanisms of vascular response to neural activation and deactivation were independent on those of responses to PaCO2 changes. CBV in a brain region is the sum of three components: arterial, capillary and venous blood volumes. It has been reported that the arterial blood volume fraction is approximately 30% in humans and that changes in human CBV during changes in PaCO2 are caused by changes in arterial blood volume without changes in venous blood volume. These findings should be considered in future studies of the pathophysiology of cerebrovascular diseases. (author) 136 refs

  14. Neutron Computed Tomography

    International Nuclear Information System (INIS)

    Computed tomography is a non-destructive testing method which can visualize cross-section of materials based on their nuclear characteristics. In the previous work, X-ray was used as its radiation media. The aim of this experiment was to improve the computed tomography technique using neutron beam. For reconstructing the cross-section image of materials, a filtered back projection was used. Result indicated that a minimum hole shown was 3 mm in diameter using a black and white presentation. While using eight colour levels, a hole of 2 mm in diameter could be seen clearly. It is expected that neutron computed tomography can improve the results of non-destructive testing. (author). 5 refs., 6 figs

  15. A study of cerebral hemodynamics in various cerebrovascular disorders by means of rCBF measurement with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Using single photon emission computed tomography (SPECT) with Xe-133 inhalation method, regional cerebral blood flow (rCBF) was measured for the purpose of analyzing the pathophysiology of various cerebrovascular disorders. Included in this series were 38 normal volunteers (N), 72 patients with ischemic cerebrovascular disease (ICD), 16 with subarachnoid hemorrhage (SAH), 9 with arteriovenous malformation (AVM), 6 with Moyamoya disease (MD), and 4 with hypertensive intracerebral hematoma (HIH). In the N group, rCBF was independent of sex and laterality. Increased rCBF was observed in the frontal region, as compared with other regions. A significantly increased rCBF was observed in the thirties decade of life; the difference in rCBF was, however, not statistically significant above the age of 30 years. In the ICD group, rCBF decreased in association with severer disorder. In cases of severe disorder, a significantly decreased rCBF was observed in the whole area, as compared with the control group. SPECT allowed early detection of decreased rCBF due to vaso-spasm in the SAH group. The groups of AVM, MD, and HIH showed decreased rCBF in the surrounding areas of the lesions. (Namekawa, K.)

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head What is CT Scanning of the Head? What are some ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography ( ... used in your exam. You should inform your physician of all medications you are taking and if ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography ( ... used in your exam. You should inform your physician of all medications you are taking and if ...

  19. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret;

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ... CT exam to be stressful. The technologist or nurse, under the direction of a physician, may offer ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ... visibility of certain tissues or blood vessels. A nurse or technologist will insert an intravenous (IV) line ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  4. Tumour blood flow and partition coefficients: correlation with grade of cerebral gliomas using xenon-enhanced computed tomography

    International Nuclear Information System (INIS)

    It is possible to underestimate the grade of nonenhancing cerebral tumours on conventional contrast-enhanced MRI or CT. Differentiation of high- and low-grade gliomas by measurement of the brain-blood partition coefficient lambda (Tλ) with Xe-enhanced CT (XeCT) has been reported. We assessed the practical applications of XeCT in suspected low-grade astrocytomas. We examined 15 patients with tumours which showed no contrast enhancement on conventional MRI and CT, using XeCT. Tumour blood flow (TBF) and Tλ were calculated. Fourteen patients underwent surgery, one patient had a biopsy. We recognised three histological groups. While Tλ differed significantly between them, TBF did not. Group 1 contained grade II-III astrocytomas and Tλ was 0.77; group 2 contained grade I-II astrocytomas with Tλ 1.14, and group 3 four oligodendrogliomas in which a Tλ of 1.50 was found. (orig.). With 4 figs., 2 tabs

  5. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-133. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission...... other tracers for CBF tomography using SPECT is summarized with emphasis on the 99mTc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers....

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  7. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  8. Cerebral emission computer tomography with a rotating gamma camera: clinic results with J-123 Isopropylamphetamin and J-123-Fenetyllin

    International Nuclear Information System (INIS)

    Many amines can pass the blood brain barrier and accumulate in relatively large amounts in the brain tissue. For about 2 years 123-J amphetamines have, therefore, been used for brain imaging by several teams. Our experience sofar is based on 28 patients. Of these, 14 were epileptics, 10 had cerebrovascular diseases, 2 suffered from migraine and another 2 had brain tumors. In 3 patients with vascular lesions studies were repeated twice or three times. Amphetamine uptake in the brain was measured with a rotating gamma camera system (Gammatome T9000/CGR). At an examination time of 20 minutes 64 frames were acquired during one full rotation. The pulse rate was about 3000 second after injecting 6.5 mCi of 123-J amphetamine. Of the epileptics, 8 showed defects both on CT and SPECT, in 3 cases both studies were normal. While 1 patient with CT positivity had a normal SPECT, 2 cases were found to have lesions on SPECT inspite of a normal CT. The size of the lesion seen on amphetamine SPECT was lager than on CT in 3 of 9 patients. In the 10 patients with cerebrovascular lesions the 2 procedures showed concordant normal patterns in 1 and concordant abnormal patterns in 7 instances. 2 patients with normal CT were found to have a lesion on amphetamine scanning which corresponded to the neurologic findings. Regarding the size of the lesions, SPECT showed a more extensive involvement than CT in 2 cases. This again was in good agreement with the neurologic findings. Inspite of repeat studies cerebellar diaschisis was only seen in a single case with healed cerebral infarction and hemiplegia of some years' standing. Two patients suffered from migraine and compromised blood flow was identified as suggested by the neurologic findings inspite of a normal CT. (Author)

  9. Sensitivity of 3D gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography angiography for detection of middle cerebral artery thrombus in acute stroke

    Directory of Open Access Journals (Sweden)

    Amit Agarwal

    2014-11-01

    Full Text Available We aimed at comparing the sensitivity of magnetic resonance (MR susceptibility-weighted imaging (SWI with computed tomography angiography (CTA in the detection of middle cerebral artery (MCA thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI and CTA. Twenty random subjects with completely normal MRI (including SWI exam were selected as control. Two neuroradiologists (blinded to the presence or absence of stroke reviewed the SW images and then compared the findings with CT angiogram (in patients with stroke. The number of MCA segments showing thrombus in each patient was tabulated to estimate the thrombus burden. Thrombus was detected on SWI in one or more MCA segments in 30 out of 35 patients, on the first review. Of the 30, SWI showed thrombus in more than one MCA segments in 7 patients. CTA depicted branch occlusion in 31 cases. Thrombus was seen on both SWI and CTA in 28 patients. Thrombus was noted in two patients on SWI only, with no corresponding abnormality seen on CTA. Two patients with acute MCA showed no vascular occlusion or thrombus on either CTA or SWI. Only two case of false-positive thrombus was reported in normal control subjects. Susceptibility-weighted images had sensitivity and specificity of 86% and 90% respectively, with positive predictive value 94%. Sensitivity was 86% for SWI, compared with 89% for CTA, and this difference was statistically insignificant (P>0.05. Of all the positive cases on CTA (31 corresponding thrombus was seen on SWI in 90% of subjects (28 of 31. Susceptibility-weighted imaging has high sensitivity for detection of thrombus in acute MCA stroke. Moreover, SWI is a powerful technique for estimation of thrombus burden, which can be challenging on CTA.

  10. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  11. Computed Tomography. Chapter 11

    International Nuclear Information System (INIS)

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors

  12. Evaluation by computed tomography in premature and newborn infants

    International Nuclear Information System (INIS)

    By means of cranio-cerebral computed tomography hypoxic brain damage of varying degrees and different types may be demonstrated in premature infants and high-risk newborns. Paraventricular leucomalacia of varying extent up to porencephalic defects are found, as well as cortical infarctions, hemorrhage into brain tissue or ventricles, cerebral atrophy, developing hydrocephalus and congenital anomalies. (orig.)

  13. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  14. Dynamic computed tomography of the brain

    International Nuclear Information System (INIS)

    Dynamic computed tomography (CT) studies of the brain are based on a rapid intravenous bolus injection of radiographic contrast material immediately followed by serial CT scans. The recycling times for this technique are 1 sec or less. Dynamic studies, which are relatively non-invasive, add considerable information to the static cerebral scan as it is presently performed. The resulting time-density patterns are described and typical examples of each are shown. (orig.)

  15. Quantitative Computed Tomography

    OpenAIRE

    Balda, Michael

    2011-01-01

    Computed Tomography (CT) is a wide-spread medical imaging modality. Traditional CT yields information on a patient's anatomy in form of slice images or volume data. Hounsfield Units (HU) are used to quantify the imaged tissue properties. Due to the polychromatic nature of X-rays in CT, the HU values for a specific tissue depend on its density and composition but also on CT system parameters and settings and the surrounding materials. The main objective of Quantitative CT (QCT) is measuring ch...

  16. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  17. Computed tomography device

    International Nuclear Information System (INIS)

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  18. Positron emission tomography and cerebral metabolism

    International Nuclear Information System (INIS)

    The association of new methods of labelling with short lived radioisotopes and of visualisation 'in vivo' of these labelled molecules by emission tomography, provide the possibility of studying brain metabolism at different levels. Two examples will illustrate the possibilities of this methodology. Cerebral metabolism of methionine-11C in phenylketonutic patients: The cerebral uptake of methionine was measured in 24 PKU children aged 1 to 40 months on a low protein diet. Ten of them were examined twice at intervals of several months. Stopping the diet for one week leads to an increase in blood phenylalanine and to a significant important decrease in brain uptake of labelled methionine. Futhermore, for children under treatment having a low phenylalanine blood concentration, brain uptake of methionine decreases with age between 1 and 40 months. These results suggest that the treatment of this disease should be started as soon as possible after birth. Cerebral metabolism of psychoactive drugs: The study of the brain distribution and kinetics of psychoactive drugs may help in understanding their mode of action. Chlorpromazine- 11C was administered i.v. to schyzophrenic patients not previously treated with neuroleptics. In all patients the brain uptake of the drug was high and rapid, and was localized mainly in the grey matter, probably in proportion to the blood flow. Non-specific binding of this drug to brain proteins prevented visualization of specific binding to dopaminergic or αnor-adrenergic receptors. Specific receptor binding of benzodiazepines was however visualized in the brain of baboons after injection of 11C-flunitrazepam (specific activity = 600 Ci/μmole) and subsequent displacement of this radioactive ligand by a pharmacological dose of Lorazepam

  19. Computed tomography of electronics

    Science.gov (United States)

    Bossi, Richard H.; Kruse, Robert J.; Knutson, Benjamin W.

    1989-12-01

    The application of Computed Tomography (CT) and laminography was tested on a variety of electronic components. The effort was performed as a preliminary testing task assignment in the Advanced Development of X ray Computed Tomography Application program. A key area for testing was printed circuit boards for the inspection of solder bonds and in particular for leadless chip carrier devices. During the course of the task assignment several other categories of electronic devices were examined including transformers, connectors, switches from solution and contrast sensitivity phantoms developed for the programs were used to establish quantitative measures of capability used to generate images. This preliminary testing of electronics lead to the conclusion that higher resolution CT scanning is needed to resolve details of interest. CT testing on commercially available system could resolve high contrast details in the range of 2 to 4 lp/mm; however, in many electronic components finer resolution is needed to detect microcracking, voiding and other features. Further testing on high resolution system is recommended. Two areas of immediate potential economic payback for electronics inspection were identified; the inspection of high volume printed circuit board production using high speed laminography and nondestructive failure analysis studies components using high-resolution CT.

  20. Computed tomography in neurocysticercosis

    International Nuclear Information System (INIS)

    Three hundred and fifty seven computed tomography (CT) from 100 different patients with neurocysticercosis (NC) were studied between 1979 and 1988. All patients were treated with praziquantel (PZQ). A new classification attempting to recognize the CT evolution profile in NC as well as assigning a possible link between CT findings and biological conditions of cysts is evaluated. It was possible to conclude that: intact cysts remain unchanged in consecutive CTs by 11 months and exhibit signs of degeneration in about 18 months after PZQ drug therapy; degenerating cysts can be detected by 10.5 months, disappear in 11 months and become nodular calcifications in about 25 months. Therefore, a time period of at least 36 months can be estimated for the complete evolution profile of cysts in the brain parenchyma. (author)

  1. Multislice computed tomography coronary angiography

    OpenAIRE

    Cademartiri, Filippo

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England, and independently by South Mrican born physicist Allan Cormack of Tufts University, Massachusetts.1 • 2 Hounsfield was later awarded the Nobel Peace Prize and honoured with K...

  2. Computed Tomography Measuring Inside Machines

    Science.gov (United States)

    Wozniak, James F.; Scudder, Henry J.; Anders, Jeffrey E.

    1995-01-01

    Computed tomography applied to obtain approximate measurements of radial distances from centerline of turbopump to leading edges of diffuser vanes in turbopump. Use of computed tomography has significance beyond turbopump application: example of general concept of measuring internal dimensions of assembly of parts without having to perform time-consuming task of taking assembly apart and measuring internal parts on coordinate-measuring machine.

  3. Computed tomography of abdominal trauma

    International Nuclear Information System (INIS)

    Abdominal lesions following an accident or surgical interventions are becoming more frequently indications for investigations by computed tomography. Changes of spleen, liver, kidneys, pancreas, and of the retroperitoneal space are discussed. Advantages of computed tomography compared to other investigative methods are shown. (orig.)

  4. Pediatric cranial computed tomography

    International Nuclear Information System (INIS)

    The introduction of CT in the investigation of intercranial pathology has revolutionized the approach to clinical neurological and neurosurgical practice. This book applies the advances of cranial CT to the pediatric patient. The test is divided into two sections. The first portion describes the practical methodology, anatomy and normal and abnormal CT scan appearance, including high or low density lesions, cystic lesions and ventricular or subarachnoid space dilation. The characteristic scans for various neurological diseases are presented and discussed. The author has given special attention to the CT diagnosis of congenital malformations and cerebral neoplasms. Partial Contents: Normal Computed Tomographic Anatomy/ High Density Lesions/Low Density Lesions/Cystic Lesions; Supratentorial/Cystic Lesions; Infratentorial/Increased Head Circumference/Increased Ventricular Size/Small Ventricular Size/Cranial Lesions/Spinal Lesions/CT Cisternography/Part II CT in Neonates/Congenital Craniocerebral Malformations/Hydrocephalus/Craniosynostosis/Head Trauma/Cerebrovascular Lesions/Intracranial Lesions/Seizure Disorders/Intracranial and Other Chronic Neurological Disorders

  5. Signs of cerebral atrophy on single-photon emission tomography.

    Science.gov (United States)

    Wong, C O; Meyerrose, G E; Sostre, S

    1994-05-01

    Cerebral atrophy often coexists with other brain disorders and by itself may alter the pattern of cerebral perfusion. If unrecognized, it may confound diagnoses based on brain single-photon emission tomography (SPET). In this retrospective study, we describe and evaluate criteria for the diagnosis of cerebral atrophy on technetium-99m hexamethylpropylene amine oxime brain SPET studies. The SPET scans of 11 patients with cerebral atrophy and ten controls were evaluated for the presence of a prominent interhemispheric fissure, presence of prominent cerebral sulci, separation of thalamic nuclei, and pronounced separation of caudate nuclei. The SPET studies were interpreted by two independent observers blind to the findings of magnetic resonance imaging, which provided the final diagnosis of cerebral atrophy. The combination of the four scintigraphic signs was accurate in the diagnosis of cerebral atrophy in 95% of the cases and had a sensitivity of 91% and a specificity of 100%. PMID:8062851

  6. Cerebral radionuclide tomography using 123I-isopropyl-amphetamine in cerebral ischaemic pathology

    International Nuclear Information System (INIS)

    Thirty patients with previous cerebral ischaemic accident were explored by both computerized tomography (CT) and radionuclide tomography after injection of 123I-labeled N-isopropyl-iodo-amphetamine. All lesions that were visible at CT were also visible at radionuclide tomography. However, in 7 patients with normal CT results the latter method showed areas of cerebral activity anatomically correlated with neurological signs or vascular lesions. Cerebellar diaschisis was observed in 50% of established lesions in the carotid territory. Radionuclide tomography therefore appears as a very sensitive method to be used in ischaemic pathology with transient or regressive accidents

  7. Spinal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sartor, K.

    1980-10-01

    Computed tomography (CT) of the spine and spinal cord is gaining more and more importance as a valuable investigative method in neuroradiology. Performed as a noninvasive procedure, with or without intravenous contrast enhancement, it can be used to diagnose paravertebral soft tissue lesions, constrictive lesions of the bony spinal canal, structure changes of the vertebral column or of individual vertebrae, vascular intraspinal lesions, and intraspinal tumors with abnormally high or abnormally low attenuation values. Performed as an invasive procedure, after intrathecal introduction of metrizamide, spinal CT can in selected cases be used in conjunction with conventional metrizamide myelography as an additional procedure (secondary CT-myelography) or even as initial procedure ( primary CT-myelography), taking advantage of its unique properties, namely to provide a transverse axial image of the spine and related soft tissue structures and to detect even small differences in density. Further improvement of spinal CT, particularly the routine non-invasive demonstration of the intraspinal soft tissues, is to be expected.

  8. Computed tomography apparatus

    International Nuclear Information System (INIS)

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  9. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  10. Measurement of regional cerebral metabolic rate for glucose in the human subject with (F-18)-2-deoxy-2-fluoro-d-glucose and emission computed tomography: validation of the method

    International Nuclear Information System (INIS)

    Tracer techniques and models of in vitro quantitative autoradiography and tissue counting for the measure of regional metabolic rates (rMR) are combined with emission computed tomography (ECT). This approach, Physiologic Tomography (PT), provides atraumatic and analytical measurements of rMR. PT is exemplified with the regional measurement of the cerebral metabolic rate for glucose (CMRGlu) in man with (18F)-2-deoxy-2-fluoro-D-glucose (FDG) and positron ECT. Our model incorporates a k4* mediated hydrolysis of FDG-6-PO4 to FDG which then competes with phosphorylation (k3*) of FDG back to FDG-6-PO4 and reverse transport (k2*) back to blood. Although small, k4* is found to be significant. The ECAT positron tomograph was used to measure the rate constants (k1*→k4*), lumped constant (LC), stability, and reproducibility of the model in man. Since these parameters have not been measured for FDG in any species, comparisons are made to values for DG in rat and monkey. Compartmental concentrations of FDG and FDG-6-PO4 were determined and show that cerebral FDG-6-PO4 steadily accumulates for about 100 mins, plateaus and then slowly decreases due to hydrolysis. Cerebral blood FDG concentration was determined to be a minor contribution to tissue activity after 10 min. Regional CMRGlu measurements are reproducible to +- 5.5% over 5 hrs. PT allows the in vivo study ofregional biochemistry and physiology in normal and pathophysiologic states in man with a unique and fundamental capability

  11. Cerebral blood flow in acute and chronic ischemic stroke using xenon-133 inhalation tomography

    DEFF Research Database (Denmark)

    Vorstrup, S; Paulson, O B; Lassen, N A

    1986-01-01

    Serial measurements of cerebral blood flow (CBF) were performed in 12 patients with acute symptoms of ischemic cerebrovascular disease. CBF was measured by xenon-133 inhalation and single photon emission computer tomography. Six patients had severe strokes and large infarcts on the CT scan. They...

  12. Quantitative computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Judith E. [Royal Infirmary and University, Manchester (United Kingdom)], E-mail: judith.adams@manchester.ac.uk

    2009-09-15

    Quantitative computed tomography (QCT) was introduced in the mid 1970s. The technique is most commonly applied to 2D slices in the lumbar spine to measure trabecular bone mineral density (BMD; mg/cm{sup 3}). Although not as widely utilized as dual-energy X-ray absortiometry (DXA) QCT has some advantages when studying the skeleton (separate measures of cortical and trabecular BMD; measurement of volumetric, as opposed to 'areal' DXA-BMDa, so not size dependent; geometric and structural parameters obtained which contribute to bone strength). A limitation is that the World Health Organisation (WHO) definition of osteoporosis in terms of bone densitometry (T score -2.5 or below using DXA) is not applicable. QCT can be performed on conventional body CT scanners, or at peripheral sites (radius, tibia) using smaller, less expensive dedicated peripheral CT scanners (pQCT). Although the ionising radiation dose of spinal QCT is higher than for DXA, the dose compares favorably with those of other radiographic procedures (spinal radiographs) performed in patients suspected of having osteoporosis. The radiation dose from peripheral QCT scanners is negligible. Technical developments in CT (spiral multi-detector CT; improved spatial resolution) allow rapid acquisition of 3D volume images which enable QCT to be applied to the clinically important site of the proximal femur, more sophisticated analysis of cortical and trabecular bone, the imaging of trabecular structure and the application of finite element analysis (FEA). Such research studies contribute importantly to the understanding of bone growth and development, the effect of disease and treatment on the skeleton and the biomechanics of bone strength and fracture.

  13. The distribution of cerebral muscarinic acetylcholine receptors in vivo in patients with dementia. A controlled study with 123IQNB and single photon emission computed tomography

    International Nuclear Information System (INIS)

    A high-affinity muscarinic receptor antagonist, 123IQNB (3-quinuclidinyl-4-iodobenzilate labeled with iodine 123), was used with single photon emission computed tomography to image muscarinic acetylcholine receptors in 14 patients with dementia and in 11 healthy controls. High-resolution single photon emission computed tomographic scanning was performed 21 hours after the intravenous administration of approximately 5 mCi of IQNB. In normal subjects, the images of retained ligand showed a consistent regional pattern that correlated with postmortem studies of the relative distribution of muscarinic receptors in the normal human brain, having high radioactivity counts in the basal ganglia, occipital cortex, and insular cortex, low counts in the thalamus, and virtually no counts in the cerebellum. Eight of 12 patients with a clinical diagnosis of Alzheimer's disease had obvious focal cortical defects in either frontal or posterior temporal cortex. Both patients with a clinical diagnosis of Pick's disease had obvious frontal and anterior temporal defects. A region of interest statistical analysis of relative regional activity revealed a significant reduction bilaterally in the posterior temporal cortex of the patients with Alzheimer's disease compared with controls. This study demonstrates the practicability of acetylcholine receptor imaging with 123IQNB and single photon emission computed tomography. The data suggest that focal abnormalities in muscarinic binding in vivo may characterize some patients with Alzheimer's disease and Pick's disease, but further studies are needed to address questions about partial volume artifacts and receptor quantification

  14. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  15. Evaluation of the middle cerebral artery occlusion techniques in the rat by in-vitro 3-dimensional micro- and nano computed tomography

    OpenAIRE

    Bachmann Georg; Kampschulte Marian; Marhoffer Simone; Ostendorf Anne; Yeniguen Mesut; Langheinrich Alexander C; Stolz Erwin; Gerriets Tibo

    2010-01-01

    Abstract Background Animal models of focal cerebral ischemia are widely used in stroke research. The purpose of our study was to evaluate and compare the cerebral macro- and microvascular architecture of rats in two different models of permanent middle cerebral artery occlusion using an innovative quantitative micro- and nano-CT imaging technique. Methods 4h of middle cerebral artery occlusion was performed in rats using the macrosphere method or the suture technique. After contrast perfusion...

  16. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl- sup 123 I-p-iodoamphetamine with single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wakisaka, M.; Nagamachi, S.; Inoue, K.; Morotomi, Y.; Nunoi, K.; Fujishima, M. (Higashi Hospital, (Japan))

    1990-10-01

    Regional cerebral blood flow was measured using N-isopropyl-{sup 123}I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis.

  17. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl-123I-p-iodoamphetamine with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Regional cerebral blood flow was measured using N-isopropyl-123I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis

  18. Regional cerebral function and blood flow: complementary single photon emission computed tomography of the brain using xenon-133 and [123I]iodoamphetamine

    International Nuclear Information System (INIS)

    Regional cerebral function and blood flow can be imaged using isopropyl[123I]iodoamphetamine (IMP), or 133Xe (DSPECT), respectively. This study assessed the in vivo information about intracerebral disease provided by IMP and DSPECT techniques to determine the optimal diagnostic use of these modalities. Single photon emission computed tomograms of 53 subjects were acquired using similar displays for IMP and DSPECT data. Overall, both IMP and DSPECT had similar patterns. However, while similar, one or the other technique often displayed abnormalities not present on both. Although technical factors may account for some differences between the modalities, a case of arteriovenous malformation proves that discordant findings can result directly from tracer localization properties. Thus at least some discordances provide truly complementary diagnostic information lacking in either single study taken alone. (author)

  19. What is Computed Tomography?

    Science.gov (United States)

    ... word "tomography" is from the Greek word "tomos" meaning "slice" or "section" and "graphe" meaning "drawing." A CT imaging system produces cross-sectional ... The patient may receive an injection of a "contrast material" to facilitate visualization of vascular structure. Detectors ...

  20. Unsuspected organic disease in chronic schizophrenia demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Unsuspected intracranial pathology was demonstrated in 12 of 136 chronic schizophrenic patients examined by computed tomography (CT). Seven cases of cerebral infarction were found, and one each of porencephalic cyst, meningioma, cystic enlargement of the pineal body, and two of subdural haematoma. Attention is drawn to the value of CT in demonstrating organic disease in schizophrenia. (author)

  1. Evaluation of the middle cerebral artery occlusion techniques in the rat by in-vitro 3-dimensional micro- and nano computed tomography

    Directory of Open Access Journals (Sweden)

    Bachmann Georg

    2010-05-01

    Full Text Available Abstract Background Animal models of focal cerebral ischemia are widely used in stroke research. The purpose of our study was to evaluate and compare the cerebral macro- and microvascular architecture of rats in two different models of permanent middle cerebral artery occlusion using an innovative quantitative micro- and nano-CT imaging technique. Methods 4h of middle cerebral artery occlusion was performed in rats using the macrosphere method or the suture technique. After contrast perfusion, brains were isolated and scanned en-bloc using micro-CT (8 μm3 or nano-CT at 500 nm3 voxel size to generate 3D images of the cerebral vasculature. The arterial vascular volume fraction and gray scale attenuation was determined and the significance of differences in measurements was tested with analysis of variance [ANOVA]. Results Micro-CT provided quantitative information on vascular morphology. Micro- and nano-CT proved to visualize and differentiate vascular occlusion territories performed in both models of cerebral ischemia. The suture technique leads to a remarkable decrease in the intravascular volume fraction of the middle cerebral artery perfusion territory. Blocking the medial cerebral artery with macrospheres, the vascular volume fraction of the involved hemisphere decreased significantly (p Conclusion Micro- and Nano-CT imaging is feasible for analysis and differentiation of different models of focal cerebral ischemia in rats.

  2. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  3. Studies of computed tomography as a contribution to differential diagnosis between dementia due to cerebrovascular disease (multi-infract type) and due to primarily degenerative cerebral atrophy (Alzheimers type)

    Energy Technology Data Exchange (ETDEWEB)

    Kohlmeyer, K.

    Studies of computed tomography were performed in 367 patients diagnosed as dementia clinically. The mean age was 70.1 years. By the clinicians 240 were classified as senile dementia of Alzheimer's type, 79 as multiinfarct dementia, and 48 were not determined definitely. In 3%, the CT studies did detect treatable causes like tumors, subdural hematomas and communicating hydrocephalus. In about 57% was found by CT a diffuse brain atrophy without focal tissue changes as to expect if occurring a cerebrovascular disease. In 25% there were focal changes of the brain tissue in CT to define as residuals of infarctions in addition to the signs of cerebral atrophy. The results of the CT studies were normal in 15% despite the evidence of dementia clinically. The analysis of the material did show that a cerebrovascular disease as a cause of dementia is suspected clinically in much more cases than CT studies are able to prove focal pathological changes of the brain tissue due to disorders of cerebral blood flow.

  4. Studies of computed tomography as a contribution to differential diagnosis between dementia due to cerebrovascular disease (multi-infract type) and due to primarily degenerative cerebral atrophy (Alzheimers type)

    International Nuclear Information System (INIS)

    Studies of computed tomography were performed in 367 patients diagnosed as dementia clinically. The mean age was 70.1 years. By the clinicians 240 were classified as senile dementia of Alzheimer's type, 79 as multiinfarct dementia, and 48 were not determined definitely. In 3%, the CT studies did detect treatable causes like tumors, subdural hematomas and communicating hydrocephalus. In about 57% was found by CT a diffuse brain atrophy without focal tissue changes as to expect if occurring a cerebrovascular disease. In 25% there were focal changes of the brain tissue in CT to define as residuals of infarctions in addition to the signs of cerebral atrophy. The results of the CT studies were normal in 15% despite of the evidence of dementia clinically. The analysis of the material did show that a cerebrovascular disease as a cause of dementia is suspected clinically in much more cases than CT studies are able to prove focal pathological changes of the brain tissue due to disorders of cerebral blood flow really. (orig.)

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  9. Assessment of cerebral perfusion in chronic tobacco users through spect (single photon emission computed tomography) using Tc-99m HMPAO(metastable technetium-99 labelled hexa-methyl propylene amine oxime)

    International Nuclear Information System (INIS)

    Objective: To determine an association between chronic tobacco use and changes in cerebral perfusion through semi-quantitative scintigraphic assessment employing metastable Technetium-99 labelled hexa-methyl propylene amine oxime single photon emission computed tomography (Tc-99m HMPAO SPECT). Design: Case-control study. Place and duration of study: The study was conducted at the Department of Medical Sciences, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Nilore, Islamabad, from Oct 2001 to May 2002. Patients and Methods: Regional cerebral perfusion in 48 chronic tobacco users was evaluated, utilising a normal database created by HMPAO brain scans of 20 non-tobacco users. Subjects were classified into chronic tobacco users and non-tobacco users through the use of the smoking index (SI). [Smoking Index = Number of years of tobacco use x Number of cigarettes smoked per day]. SI value of 100 was taken as the cut-off value. Regions of interest (ROIs) were declared hypo perfused or hyper perfused if their percentage perfusion values relative to the average perfusion per pixel of the whole slice under evaluation did not fall within + 2 standard deviation (SD) of the mean regional perfusion in the corresponding ROI, in the normal control group. Result: Chronic tobacco users showed 164 hypo perfused ROIs (6.57%) and 138 hyper perfused ROIs (5.53%) out of 2496 ROIs assessed, whereas the normal controls showed only 15 hypo perfused (1.44%) and 27 hyper perfused (2.60%) ROIs out of 1040 ROIs assessed (P < 0.001). Conclusion: Cerebral perfusion in chronic tobacco users was found to be significantly decreased compared to the non-tobacco users. (author)

  10. Computer tomography in acute pyelonephritis

    Energy Technology Data Exchange (ETDEWEB)

    Triller, J.; Scheidegger, J.; Terrier, F.

    1983-07-01

    Computer tomography of the kidneys was performed on 30 patients with acute renal infections (acute suppurative pyelonephritis, acute renal abscess, infected cyst, pyelonephrosis, calculus perforation, retroperitoneal abscess). Computer tomography provided more accurate information concerning the extent of the renal and extra-renal inflammatory process than did the urogram or sonogram. This may significantly affect the choice of treatment, particularly concerning the use of drugs or of surgery. Angiography and retrograde pyelography may be used in selected cases, especially where there is a suspicion of acute bacterial nephritis, renal vein thrombosis or ureteric obstruction.

  11. Computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Computed tomography (CT) is a new non-invasive diagnostic imaging method, which has ability to differentiate C.S.F., hematoma, and even edematous brain from normal brain tissue. Prior to the introduction of the CT, the diagnosis of the intraventricular hemorrhage in living patients was difficult and was confirmed by surgery of autopsy. Intracranial hemorrhages are visible on the CT with density higher than brain tissue in acute phase. CT is an accurate method for detecting of intraventricular hemorrhage including detection of nature, location, amount, and associated changes. CT is also useful as a guidance and in the evaluation of fate of the hematomas by easily performable follow up studies. The causes of the intraventricular hemorrhages are hypertension, rupture of aneurysm, arteriovenous malformation, head trauma, brain tumor, and others. This study included evaluation of CT of 69 patients who show the high density in cerebral ventricular system during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 69 patient was broad ranging from 1 month to 80 years. 28% of patients were in the 6th decade. The mate to female ratio was 2 : 1. 2. The consciousness of patients at CT study: Those were conscious in 11 cases, stuporous in 41 cases and unconscious in 17 cases. 3. The causes of intraventricular hemorrhages were hypertension in 28 cases, head trauma in 12 cases, aneurysm in 4 cases, tumor in 2 cases and others in 23 cases. 4. 9 cases showed intraventricular hematomas only, other 60 cases showed associated intracranial hematomas: Those were intracerebral hematomas in 53 cases including 30 cases of basal ganglial and thalamic hematomas, subarachnoid hemorrhage in 17 cases, epidural hematomas in 3 cases, and subdural hematomas in 2 cases. 5. All cases of the intraventricular hematomas except one sowed hematoma in the lateral

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  14. Emission computed tomography

    International Nuclear Information System (INIS)

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99/sup m/Tc, 201Tl, 123I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... to reduce the risk of an allergic reaction. These medications generally need to be taken 12 hours ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... to reduce the risk of an allergic reaction. These medications generally need to be taken 12 hours ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a gantry. The computer workstation that processes the imaging information is located in a separate control room, ... which are then displayed on a monitor. CT imaging is sometimes compared to looking into a loaf ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a gantry. The computer workstation that processes the imaging information is located in a separate control room, ... which are then displayed on a monitor. CT imaging is sometimes compared to looking into a loaf ...

  5. Computed tomography of intramuscular myxoma

    International Nuclear Information System (INIS)

    Computed tomography (CT) was performed in seven patients with intramuscular myxoma. All lesions were well demarcated, of homogeneous appearance and attenuation values ranging from 10 to 60 (HU). The tumor size, as estimated at CT, correlated well with the size of the surgical specimen, which is in contrast to the findings in some high grade malignant sarcomas. (orig.)

  6. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  7. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.;

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  8. Computed tomography for dimensional metrology

    DEFF Research Database (Denmark)

    Kruth, J.P.; Bartscher, M.; Carmignato, S.;

    2011-01-01

    The paper gives a survey of the upcoming use of X-ray computed tomography (CT) for dimensional quality control purposes: i.e. for traceable measurement of dimensions of technical (mechanical) components and for tolerance verification of such components. It describes the basic principles of CT...

  9. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    The positron computed tomography facility has got scintillator detector rings simultaneously recording more than one tomogrphic image of different cross-sections of the patient. The detectors in neighboring rings are staggered and can be rotated with respect to each other in order to increase the count rate without loss of efficiency. (DG)

  10. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  11. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other in a ring, called a gantry. The computer workstation that processes the imaging information is located in a separate control room, where ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other in a ring, called a gantry. The computer workstation that processes the imaging information is located in a separate control room, where ...

  16. APPLICATION OF SINGLE PHOTON EMMISSION COMPUTED TOMOGRAPHY TO CLINICAL STUDY ON THE THERAPEUTIC EFFECT OF ACUPUNCTURE IN TREATMENT OF CHILD CEREBRAL PARALYSIS

    Institute of Scientific and Technical Information of China (English)

    于海波; 鞠琰莉; 贾少微

    2001-01-01

    Subjective: To identify the practicability and clinical values of acupuncture in the treatment of child cerebral paralysis, try to provide visualized evidence and mechanisms for acupuncture treatment of this disease. Methods: 13 cerebral palsy children including 9 cases of spasmodic type, 2 cases of ataxia type and 2 cases of mixed type, 9 males and 4 females were subjected into this study. Acupoints used were Hegu (LI 4), Quchi (LI 11 ), Zusanli (ST 36) and Sanyinjiao (SP 6) that were punctured and stimulated electrically with parameters of frequency 2/15 Hz, electric current 5 mA, and duration of stimulation 30 min. Under monitoring of Siemens ECAM/ICON SPECT System, blood flow volumes of different brain regions were observed before, during and after elctroacupuncture (EA) stimulation of the above-mentioned acupoints. Results: SPECT revealed that in these 13 infantile patients, 18 regions of the brain in-cluding 12 in the frontal lobe and 6 in the temporal lobe presented insufficiency of blood perfusion and hypofunction; during EA, these cerebral regions and parietal lobe, visual cortex, thalamus, basal ganglion and cerebellum showed improvement in blood perfusion and function in different degrees. Results of the quantitative analysis on blood flow function changing rate (BFCR)% showed a significant increase in 83.3 % of the focal regions during EA. Conclusion: Acupuncture therapy can effectively improve cerebral blood perfusion of the focus and is of clinical value in treatment of infantile cerebral paralysis.

  17. Cerebral toxoplasmosis in AIDS - computerized tomography evaluation

    International Nuclear Information System (INIS)

    Cerebral toxoplasmosis is a disease that affects many AIDS's patients. FOr this paper 46 patients with confirmed cases of cerebral toxoplasmosis who did a CT scan between March, 1994 and September, 1997 were examined. Single lesions were found in 28.3% of the patients. The lesions were more frequently detected in the basal ganglia and the frontal lobes. No lesion was larger than 4 cm. As regards the contrast enhancing of the lesions on a CT scan we observed that 54.5% of the lesions had a ring-like contrast enhancing, 36.4% had a nodular contrast enhancing and 6% had a heterogeneous form. After the 21st day of treatment we noticed an improvement in the aspect of the patients'lesions. The improvement of the lesions could be seen through a reduction of the edematous halo, a reduction of the lesion size and a modification in the contrast enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility with cerebral toxoplasmosis, as well as to monitor these patients during treatment. (author)

  18. Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling

    International Nuclear Information System (INIS)

    Magnetic induction tomography (MIT) is a new electromagnetic imaging modality which has the potential to image changes in the electrical conductivity of the brain due to different pathologies. In this study the feasibility of detecting haemorrhagic cerebral stroke with a 16-channel MIT system operating at 10 MHz was investigated. The finite-element method combined with a realistic, multi-layer, head model comprising 12 different tissues, was used for the simulations in the commercial FE package, Comsol Multiphysics. The eddy-current problem was solved and the MIT signals computed for strokes of different volumes occurring at different locations in the brain. The results revealed that a large, peripheral stroke (volume 49 cm3) produced phase changes that would be detectable with our currently achievable instrumentation phase noise level (17 m°) in 70 (27%) of the 256 exciter/sensor channel combinations. However, reconstructed images showed that a lower noise level than this, of 1 m°, was necessary to obtain good visualization of the strokes. The simulated MIT measurements were compared with those from an independent transmission-line-matrix model in order to give confidence in the results

  19. Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling.

    Science.gov (United States)

    Zolgharni, M; Ledger, P D; Armitage, D W; Holder, D S; Griffiths, H

    2009-06-01

    Magnetic induction tomography (MIT) is a new electromagnetic imaging modality which has the potential to image changes in the electrical conductivity of the brain due to different pathologies. In this study the feasibility of detecting haemorrhagic cerebral stroke with a 16-channel MIT system operating at 10 MHz was investigated. The finite-element method combined with a realistic, multi-layer, head model comprising 12 different tissues, was used for the simulations in the commercial FE package, Comsol Multiphysics. The eddy-current problem was solved and the MIT signals computed for strokes of different volumes occurring at different locations in the brain. The results revealed that a large, peripheral stroke (volume 49 cm(3)) produced phase changes that would be detectable with our currently achievable instrumentation phase noise level (17 m degrees ) in 70 (27%) of the 256 exciter/sensor channel combinations. However, reconstructed images showed that a lower noise level than this, of 1 m degrees , was necessary to obtain good visualization of the strokes. The simulated MIT measurements were compared with those from an independent transmission-line-matrix model in order to give confidence in the results. PMID:19491437

  20. Study on cerebral microcirculation by Optical Doppler Tomography

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale. Rats with cranial window are used as a model, and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system, under electrical stimulation and drug administration. The results show significant differences in the blood flow velocity between experimental groups and control groups, demonstrating the feasibility of ODT in the cerebral microcircula- tion study. Compared with the conventional Doppler ultrasound, ODT provides much higher spatial resolution, and thus holds a promising future in the application of the cerebral microcirculation study, especially in the observation of the blood flow velocity in micrometer scale vessels.

  1. Positron emission tomography/computed tomography.

    Science.gov (United States)

    Townsend, David W

    2008-05-01

    Accurate anatomical localization of functional abnormalities obtained with the use of positron emission tomography (PET) is known to be problematic. Although tracers such as (18)F-fluorodeoxyglucose ((18)F-FDG) visualize certain normal anatomical structures, the spatial resolution is generally inadequate for accurate anatomic localization of pathology. Combining PET with a high-resolution anatomical imaging modality such as computed tomography (CT) can resolve the localization issue as long as the images from the two modalities are accurately coregistered. However, software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. Acquiring both CT and PET images in the same scanner obviates the need for software registration and routinely provides accurately aligned images of anatomy and function in a single scan. A CT scanner positioned in line with a PET scanner and with a common patient couch and operating console has provided a practical solution to anatomical and functional image registration. Axial translation of the couch between the 2 modalities enables both CT and PET data to be acquired during a single imaging session. In addition, the CT images can be used to generate essentially noiseless attenuation correction factors for the PET emission data. By minimizing patient movement between the CT and PET scans and accounting for the axial separation of the two modalities, accurately registered anatomical and functional images can be obtained. Since the introduction of the first PET/CT prototype more than 6 years ago, numerous patients with cancer have been scanned on commercial PET/CT devices worldwide. The commercial designs feature multidetector spiral CT and high-performance PET components. Experience has demonstrated an increased level of accuracy and confidence in the

  2. Computed tomography of gynecologic diseases

    International Nuclear Information System (INIS)

    Although computed tomography (CT) provides superb images of all areas of the body, sonography, because of its lack of ionizing radiation and its real-time and multiplanar capacities, has become the preferred initial method of evaluating the female pelvis. This has resulted in a relative paucity of information in the literature concerning CT features of benign pelvic disorders in particular and prompted the authors to review our experience with third-generation CT scanning of the uterus and ovaries

  3. Hermaphroditism demonstrated by computed tomography

    International Nuclear Information System (INIS)

    The categorization of disorders of gender differentiation is based on chromosome analysis, physical examination, gonadal histology, and endocrine evaluation. In most cases of hermaphroditism, radiologic studies have been limited to assessment of associated urinary tract anomalies before surgical revconstruction. Noninvasive evaluation with computed tomography (CT) or sonography is potentially useful for investigation of internal pelvic anatomy in these cases. A case report of a 65-year-old man is reported

  4. Hermaphroditism demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, M.E.

    1983-07-01

    The categorization of disorders of gender differentiation is based on chromosome analysis, physical examination, gonadal histology, and endocrine evaluation. In most cases of hermaphroditism, radiologic studies have been limited to assessment of associated urinary tract anomalies before surgical revconstruction. Noninvasive evaluation with computed tomography (CT) or sonography is potentially useful for investigation of internal pelvic anatomy in these cases. A case report of a 65-year-old man is reported. (KRM)

  5. Positron Emission Tomography—Computer Tomography Scan Used as a Monitoring Tool Following Cellular Therapy in Cerebral Palsy and Mental Retardation—A Case Report

    OpenAIRE

    Sharma, Alok; Sane, Hemangi; Paranjape, Amruta; Gokulchandran, Nandini; Kulkarni, Pooja; Nagrajan, Anjana; Badhe, Prerna

    2013-01-01

    Cerebral palsy (CP) is one of the non-progressive neurological diseases caused by damage to the brain tissue at birth, which leads to physical, cognitive and perceptive symptoms. Even after lifelong medical and therapeutic management there are residual deficits which affect the quality of life of the patients and their families. We examined a maximally rehabilitated, 20 year old male suffering from CP and Mental Retardation (MR). He had diplegic gait and Intelligence Quotient (IQ) score of 44...

  6. Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography in patients with major cerebral artery steno-occlusive diseases

    International Nuclear Information System (INIS)

    Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography (SPECT) were prospectively investigated in 100 patients with major cerebral artery, atherosclerotic, and steno-occlusive diseases. All patients underwent two SPECT studies (with and without acetazolamide challenge) at an interval of 2 or 3 days, received a questionnaire immediately after each SPECT study, and returned the answered questionnaire within 7 days after the study. None of the 100 patients studied experienced any symptoms during the SPECT study without acetazolamide challenge. Sixty-three patients (63%) developed symptoms during the SPECT study with acetazolamide challenge, such as headache, nausea, dizziness, tinnitus, numbness of the extremities, motor weakness of the extremities, and general malaise 1-3 hours (mean 1.6 hours) after administration of acetazolamide, and these symptoms lasted for 0.5-72 hours (mean 7.9 hours). Multivariate statistical analysis revealed that younger age (95% confidence interval [CI] 0.896-0.980, p=0.0047) and female sex (95% CI 1.178-16.129, p=0.0274) were significantly associated with development of symptoms with acetazolamide challenge. The incidences of the development of symptoms with acetazolamide challenge were 91% (21/23) and 41% (12/29) in subgroups of women <70 years and men ≥70 years, respectively. Patients should be informed of such adverse effects of intravenous acetazolamide administration prior to the acetazolamide challenge test for evaluation of cerebrovascular reactivity. (author)

  7. Cranial computed tomography in infantile spasms

    International Nuclear Information System (INIS)

    Out of 109 children with infantile spasms (IS), prospectively tested during the years 1976 to 1979 in Denmark, 52 children were examined by cranial computed tomography (CT). The classification of IS into cryptogenic (CR), symptomatic (SY) and doubtful (DO) was done clinically without considering the CT-finding. Sixty per cent of the scannings were abnormal. Only 6/30 (20%) of the children in ACTH treatment were found to develop cerebral atrophy which means that this finding is not an obligatory side-effect of ACTH treatment of children with IS. Normal CT-findings were found in 50% of the CR and 50% of the SY + DO-groups, and could not be used as a prognostic tool for estimating the mental development. This was also the case for children with cerebral atrophy. Abnormal CT-findings (minus atrophy) were highly correlated to the group with clinical symptoms and indicate an extremely unsatisfying long-term mental prognosis. CT-scanning is a valuable tool for the examination of clearing children with infantile spasms. (authors)

  8. Development of radioiodinated receptor ligands for cerebral single photon emission tomography

    International Nuclear Information System (INIS)

    In the last decade the use of radiolabeled ligands for the imaging of cerebral receptors by emission computed tomography (ECT) has seen rapid growth. The opportunity to routinely perform cerebral single photon emission tomography (SPET) with iodine-123-labeled ligands depends on the availability of receptor ligands into which iodine can be introduced without decreasing the required high target receptor specificity. The use of iodine-123-labeled receptor-specific ligands also depends on the availability of high purity iodine-123 at reasonable costs and the necessary imaging instrumentation. In this paper, the development and current stage of evaluation of various iodine-123-labeled ligands for SPET imaging of dopaminergic, serotonergic and muscarinic acetylcholinergic receptor classes are discussed

  9. Computed tomography of rambouillet sheep affected with neuronal ceroid lepofuscinosis

    International Nuclear Information System (INIS)

    Computed tomography (CT) was performed on 3 normal Rambouillet sheep and 6 Rambouillet sheep affected with neuronal ceroid lipofuscinosis. Characteristic lesions seen in the brain of affected sheep included dramatically enlarged lateral ventricles and reduced cerebral thickness. The lesions were seen in sheep as young as 4 months of age. Antemortem CT observations correlated well with postmortem findings in this model of Neuronal Ceroid Lipofuscinosis

  10. Single-Photon Emission Computed Tomography in Neurotherapeutics

    OpenAIRE

    Devous, Michael D.

    2005-01-01

    Summary: The measurement of regional cerebral blood flow (rCBF) by single-photon emission computed tomography (SPECT) is a powerful clinical and research tool. There are several clinical applications now documented, a substantial number under active investigation, and a larger number yet to be studied. Standards regarding patient imaging environment and image presentation are becoming established. This article reviews key aspects of SPECT functional brain imaging in clinical practice, with a ...

  11. Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun-Suk; Chung, Tae-Sub; Baek, Jang Hun; Suh, Sang Hyun [Gangnam Severance Hospital, Department of Radiology, Yonsei University College of Medicine, Gangnam-gu, Seoul (Korea, Republic of); Ahn, Sung Jun [Severance Hospital, Department of Radiology, Yonsei University College of Medicine, Seodaemun-gu, Seoul (Korea, Republic of); Chong, KyoungHoon [Siemens Healthcare Korea, Seodaemun-gu, Seoul (Korea, Republic of)

    2015-05-01

    To determine the feasibility of using a 70-kVp protocol compared with a 120-kVp protocol for cerebral CT angiography. An additional target was to investigate a possible reduction in the volume of contrast medium (CM) using the 70-kVp protocol. Attenuation value and CNR for iodine were determined at various tube voltage settings using a phantom. Sixty-nine volunteers were randomly assigned to one of three protocols: group A (120-kVp and CM 64 mL), group B (70-kVp and CM 64 mL), or group C (70-kVp and CM 40 mL). The attenuation value, SNR, and CNR of cerebral arteries, subjective image quality, and radiation dose were compared among the groups. The vascular attenuation, SNR, and CNR of group B were significantly higher than those of group A. Group C had a significantly higher vascular attenuation than group A. Groups B and C were significantly better than group A with respect to subjective image quality. An effective dose of 70-kVp was 10 % lower than that of 120-kVp. Using 70-kVp improved arterial enhancement, SNR, and CNR, and provided better subjective image quality, using a 10 % lower effective dose. Furthermore, the 70-kVp protocol may both reduce volume of CM by 37.5 % and improve arterial enhancement. (orig.)

  12. The usefulness of computed tomography angiography comparing to Duplex Doppler Ultrasound in the diagnosis of carotid artery stenosis in patients with cerebral circulation insufficiency symptoms

    International Nuclear Information System (INIS)

    To compare diagnostic usefulness of CT angiography (angioCT) vs. Dupplex Doppler Ultrasound (US) in the evaluation of extracranial internal carotid stenosis. The results of extracranial carotid angioCT and US were compared in 70 cases of patients with cerebral circulation insufficiency syndromes. The degree of stenosis was measured according to NASCET. Correlation, contingency and regression coefficients were used to assess the convergence between angioCT and US. The morphology of atherosclerotic plaque depicted in angioCT was assessed as well, and the results were compared to US. Additionally, in 33 patients cerebral angioCT was performed to exclude surgery contraindications. The value of correlation coefficient, which measures the angioCT vs. US convergence in the assessment of carotid artery stenosis, is 0.96. The results correspond best in following groups of cases: normal arteries and occluded arteries (CC contingency coefficient values are 0.68 and 0.65). A statistically significant dependence occurs also in atherosclerotic plaque morphology imaging (Chi=42.114; p=0.0001; CC=0.636). The high degree of convergence between angioCT and US in assessing the extracranial carotid artery stenosis was recorded. AngioCT is useful as the complementary diagnostic method in cases of difficult anatomy, artery loops or kinking. A precise assessment of 'soft' atherosclerotic plaques morphology is not possible with angioCT, but artery wall calcifications are better depicted with this method. (author)

  13. Prognostic value of reduced discrimination and oedema on cerebral computed tomography in a daily clinical cohort of out-of-hospital cardiac arrest patients

    DEFF Research Database (Denmark)

    Langkjær, Sandra; Hassager, Christian; Kjaergaard, Jesper; Salam, Idrees; Thomsen, Jakob Hartvig; Lippert, Freddy K; Wanscher, Michael; Køber, Lars; Nielsen, Niklas; Søholm, Helle

    2015-01-01

    . The primary endpoint was 30-day mortality analysed by log-rank and multivariate Cox-regression analyses. RESULTS: A cCT scan was performed in 341(30%) of the clinical OHCA-cohort, and an early CT (<24h) was performed in 188 patients. The early CT was found 'normal' in 163(89%) and with reduced......(60%), 'cerebral bleeding' in 4(3%), 'new cerebral infarction' in 10(7%), and 'reduced discrimination between white and grey matter and/or oedema' in 45(30%) patients. 'Reduced discrimination and/or oedema' by late cCT was independently associated with higher 30-day mortality compared to patients with a normal...... late CT (HR(adjusted) = 2.6 (95%CI: 1.4-4.8, p = 0.002). CONCLUSION: Our observations suggest that a cCT may be useful as part of the neurological prognostication in patients with OHCA. 'Reduced discrimination between white and grey matter and/or oedema' on cCT was independently associated with a poor...

  14. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... Tools & Resources Stroke More Single Photon Emission Computed Tomography (SPECT) Updated:Sep 11,2015 What is a ... Heart Attack Myocardial Perfusion Imaging (MPI) Positron Emission Tomography (PET) Radionuclide Ventriculography, Radionuclide Angiography, MUGA Scan Heart ...

  15. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  16. The history of computed tomography

    International Nuclear Information System (INIS)

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ)

  17. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  18. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    For positron computed tomography two or more rings of scintillation detectors are used by which three or more sections of the object may be determined at a time. The rings are placed in parallel planes having got some distance from each other, axially movable collimator rings being provided for. Each collimator can be moved towards the opposite collimator and towards a central collimator which also is ring-shaped and is placed between the rows of detectors. The external and internal collimator are used for data selection and image-forming. (DG)

  19. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    Modern diagnostic imagining techniques are gaining popularity in forensic medicine. Denmark has been involved in the development of this use of imaging techniques from the beginning. The Institute of Forensic Medicine at the University of Southern Denmark acquired a helical computed tomography (CT...... AND METHODS: This thesis investigated 900 forensic cases that were CT-scanned and autopsied at the Institute of Forensic Medicine, University of Southern Denmark, from 2006-2011. The scanner was a Siemens Somatom Spirit dual-slice CT-scanner with a Siemens Syngo MultiModality workstation. Contrast enhancement...

  20. Measurement of regional cerebral blood flow by positron emission tomography

    International Nuclear Information System (INIS)

    The principal advantage of positron emission tomography over other methods for measuring cerebral blood flow stems from the accurate, quantitative three-dimensional measurements of regional brain radioactivity that are possible with this technique. As a result, accurate quantitative measurements of regional cerebral blood flow can be obtained for both superficial and deep cerebral structures. The value of PET for investigating central nervous system physiology and pathology extends far beyond this, however. Through the use of different radiotracers and appropriate mathematical models, PET can be applied to the measurement of a wide variety of physiologic variables. Measurements of rCBF tell only part of the story. Experience with PET and with a variety of other techniques has taught us that rCBF is at times a poor indicator of the metabolic, functional, and biochemical status of cerebral tissue. It is only by understanding the interaction of all of these factors that our understanding of neurologic disease can advance. It is in the investigation of these complex relationships that the real value of PET resides

  1. Canonical computations of cerebral cortex.

    Science.gov (United States)

    Miller, Kenneth D

    2016-04-01

    The idea that there is a fundamental cortical circuit that performs canonical computations remains compelling though far from proven. Here we review evidence for two canonical operations within sensory cortical areas: a feedforward computation of selectivity; and a recurrent computation of gain in which, given sufficiently strong external input, perhaps from multiple sources, intracortical input largely, but not completely, cancels this external input. This operation leads to many characteristic cortical nonlinearities in integrating multiple stimuli. The cortical computation must combine such local processing with hierarchical processing across areas. We point to important changes in moving from sensory cortex to motor and frontal cortex and the possibility of substantial differences between cortex in rodents vs. species with columnar organization of selectivity. PMID:26868041

  2. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  3. Computed tomography of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    The cranial computed tomography (CT) is a new radiological technique with which, for the first time, minimal differences an attenuation by intracranial soft tissue can be measured exactly. The basic physical principles of computed tomography have been extensively presented by Hounsfield (1973). It is well established that the attenuation of extravasated blood measures between 35 and 45 Hounsfield units. Therefore no difficulty should be encountered in the recognition and diagnosis of extra-axial hematoma and cerebral contusion since the density of the brain parenchyma never measures more than 25 units. As the constant increase in high velocity accidents and violence, the problem of acute head injury is one of the matters of great importance in today's medical practice. Therefore it is very important to figure out the method that would allow us to diagnose easily and precisely the effects of trauma upon the brain in order to institute the proper treatment at the earliest possible moment. Computed tomography allows us to make a diagnosis quickly and in a non-invasive manner. The CT scan was carried out on 310 head trauma cases in the department of radiology, St. Mary's and Kang Nam St. Mary's Hospital, Catholic Medical College, for 16 months from June 1979 to October 1980. All the scans were obtained with the Hitachi CT-H2 scanner and the scans were repeated following intravenous injection of high dose of contrast media (roughly 1.8 cc per kg body weight of 60% Conray). We have reviewed the CT scans of 310 patients got acute head injury in order to assess the location of brain lesions, the relationship between the CT densities of hematomas and their stage, the shape and mass effect of the extra-axial hematomas, and the effect of contrast enhancement. The results were as follows: 1. Of all 310 cases of the head injuries, epidural hematoma was 13.5%, subdural hematoma was 8.7%, subdural hygroma was 10%, cerebral contusion was 39%, hydrocephalus and atrophy was 3.9% and

  4. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can...

  5. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and comp

  6. Computed tomography of Wallerian degeneration

    International Nuclear Information System (INIS)

    CT findings of wallerian degeneration of the pyramidal tract at the midbrain (atrophy of cerebral peduncle following cerebrovascular accident) were studied in 34 patients (44 CT scans) with old cerebrovascular accidents. Severe atrophy of cerebral peduncle was noted when the ipsilateral motor cortex was involved. However, when the posterior limb of the internal capsule was involved, atrophy of the ipsilateral cerebral peduncle was mild. In this series, the shortest interval between cerebrovascular accident and wallerian degeneration was 8 month. (author)

  7. Computational analysis of cerebral cortex

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Abe, Osamu; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine, Tokyo (Japan)

    2010-08-15

    Magnetic resonance imaging (MRI) has been used in many in vivo anatomical studies of the brain. Computational neuroanatomy is an expanding field of research, and a number of automated, unbiased, objective techniques have been developed to characterize structural changes in the brain using structural MRI without the need for time-consuming manual measurements. Voxel-based morphometry is one of the most widely used automated techniques to examine patterns of brain changes. Cortical thickness analysis is also becoming increasingly used as a tool for the study of cortical anatomy. Both techniques can be relatively easily used with freely available software packages. MRI data quality is important in order for the processed data to be accurate. In this review, we describe MRI data acquisition and preprocessing for morphometric analysis of the brain and present a brief summary of voxel-based morphometry and cortical thickness analysis. (orig.)

  8. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  9. Diagnostic usefulness of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Tsugawa, R.; Yamakawa, Y. (Kanazawa Medical Univ., Uchinada, Ishikawa (Japan))

    1981-07-01

    Computed tomography (CT) has been used as a diagnostic technique in various urological diseases. Here demonstrated is a case of ureteral incontinence with double renal pelvis whose upper one has ectopic ureteral orifice. Also a case of ureteral stricture in transplanted kidney and three cases of uric acid calculi are demonstrated. CT provides accurate information in each diagnostic procedure. The use of CT in the diagnosis of urinary stones is estimated. CT number of 75 stones with single component shows specific distribution in relation to the component; ex. calcium stones: 900 - 1000, cystine: 700 - 800, struvite: 600 - 700, uric acid: 400 - 500. Structure and component of the stone is easily demonstrated by CT, especially about nonopaque calculi, whose image is positively displayed only by CT.

  10. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  11. COMPUTED TOMOGRAPHY PERITONEAL CANCER INDEX

    Directory of Open Access Journals (Sweden)

    Tiutiuca RC

    2006-07-01

    Full Text Available Peritoneal surface malignancy results from seeding of gastrointestinal cancer or abdomino-pelvic sarcoma, or it can occur as a primary disease, such as peritoneal mesothelioma. In the past, this clinical situation was treated only with palliative intent. Actual treatment options for surgical management uses cytoreductive surgery which combines peritonectomy and visceral resection in an effort to remove all visible cancer within the abdomen and pelvis. Then the peritoneal cavity is flooded with chemotherapy solution. To select patients for this agressive approach quantitative prognostic indicators for carcinomatosis must be evaluated. The peritoneal cancer index (PCI is a synthesis of the distribution of tumor and a lesion size score. In such conditions abdominal medium contrast computed-tomography it is very helpful in identification of neoplasic implants.

  12. Diagnostic usefulness of computed tomography

    International Nuclear Information System (INIS)

    Computed tomography (CT) has been used as a diagnostic technique in various urological diseases. Here demonstrated is a case of ureteral incontinence with double renal pelvis whose upper one has ectopic ureteral orifice. Also a case of ureteral stricture in transplanted kidney and three cases of uric acid calculi are demonstrated. CT provides the accurate information in each diagnostic procedure. The use of CT in the diagnosis of urinary stones is estimated. CT number of 75 stones with single component shows specific distribution in relation to the component; ex. calcium stones: 900 - 1000, cystine: 700 - 800, struvite: 600 - 700, uric acid: 400 - 500. Structure and component of the stone is easily demonstrated by CT, especially about nonopaque calculi, whose image is positively displayed only by CT. (author)

  13. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...

  14. Computed tomography studies on patients with mucopolysaccharidoses

    International Nuclear Information System (INIS)

    The appearances on computed tomography (CT) in eight patients with mucopolysaccharidosis Type I, two with mucopolysaccharidosis Type II and two with mucopolysaccharidosis Type IIIB are presented. Reference is also made to two further cases in which the CT showed special features. Follow-up scans were obtained to assess the evolution of the changes. The place of CT in the diagnosis of complications due to thecal involvement is examined. The density of grey matter on the CT scans was similar to that of normal brain. Inhaled xenon did not produce any special enhancement which could be helpful in assessing the degree of the mucopolysaccharide deposition within cerebral cells. Symmetrical low attenuation in the white matter was a very common finding. This work has shown that the stage in the evolution of the mucopolysaccharidoses at which hydrocephalus develops as a complication is highly variable and CSF diversion procedures are sometimes indicated to improve the quality of the patients' lives. These indications are briefly discussed. We consider that CT is essential for the adequate appraisal of these patients and to identify some treatable complications. (orig./MG)

  15. Nano-computed tomography. Technique and applications

    International Nuclear Information System (INIS)

    Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols, a superior spatial resolution up to 400 nm (10 % MTF) can be achieved, thereby exceeding the resolution capacity of typical micro-CT systems. The technical concept of nano-CT imaging as well as the basics of specimen preparation are demonstrated exemplarily. Characteristics of atherosclerotic plaques (intraplaque hemorrhage and calcifications) in a murine model of atherosclerosis (ApoE(-/-)/LDLR(-/-) double knockout mouse) are demonstrated in the context of superior spatial resolution in comparison to micro-CT. Furthermore, this article presents the application of nano-CT for imaging cerebral microcirculation (murine), lung structures (porcine), and trabecular microstructure (ovine) in contrast to micro-CT imaging. This review shows the potential of nano-CT as a radiological method in biomedical basic research and discusses the application of experimental, high resolution CT techniques in consideration of other high resolution cross-sectional imaging techniques.

  16. Positron emission tomography in aging and dementia: effect of cerebral atrophy

    International Nuclear Information System (INIS)

    The spatial resolution of current positron emission tomography (PET) scanners does not allow a distinction between cerebrospinal fluid (CSF) containing spaces and contiguous brain tissue. Data analysis strategies which therefore purport to quantify cerebral metabolism per unit mass brain tissue are in fact measuring a value which may be artifactually reduced due to contamination by CSF. We studied cerebral glucose metabolism (CMRglc) in 17 healthy elderly individuals and 24 patients with Alzheimer's dementia using [18F]fluorodeoxyglucose and PET. All subjects underwent x-ray computed tomography (XCT) scanning at the time of their PET study. The XCT scans were analyzed volumetrically, in order to determine relative areas for ventricles, sulci, and brain tissue. Global CMRglc was calculated before and after correction for contamination by CSF (cerebral atrophy). A greater increase in global CMRglc after atrophy correction was seen in demented individuals compared with elderly controls (16.9% versus 9.0%, p less than 0.0005). Additional preliminary data suggest that volumetric analysis of proton-NMR images may prove superior to analysis of XCT data in quantifying the degree of atrophy. Appropriate corrections for atrophy should be employed if current PET scanners are to accurately measure actual brain tissue metabolism in various pathologic states

  17. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  18. Computed tomography in epidural abscess, subdural empyema, meningitis, and brain abscess

    International Nuclear Information System (INIS)

    Computerised tomography cannot be of great help in diagnosing meningitis. Examination of the cerebrospinal fluid remains essential. After the inflammation of the meninges has progressed to some stage of encephalitis, the formation of an abscess can be located via computed tomography. It is characterised by the ring-type abscess capsule. Computed tomography for diagnostic purposes is superior to cerebral scanning, which demonstrates enhanced activity, but does not show the formation of a membrane, so essential for differential diagnosis. Furthermore, computed tomography shows the adjacent anatomical structures and answers the questions of displacements and threatening invasion of the ventricle system. Epidural and subdural abscesses can also be located by computed tomography. Therapy can begin directly after computerised tomography, whereas in scintigraphy only a non-specific enhanced activity is present, which often does not allow differentiation between epidural and subdural location. (orig.)

  19. Fracture of the orbit: computed tomography appearance

    International Nuclear Information System (INIS)

    The main mechanisms of orbital fractures and their clinical symptoms are exposed. The computed tomographic appearance is described and the implication of computed tomography for therapeutic indications is evaluated as a function of clinical symptoms: visual impairment, anomaly of pupillary reaction to light, ophthalmoplegia, exophthalmos and associated injuries such as intracranial hematomas. The role of computed tomography for the follow-up of these patients is considered

  20. Computed tomography of obstructive jaundice

    International Nuclear Information System (INIS)

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst

  1. Computed tomography of obstructive jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jung Hek; Lee, Joong Suk; Chun, Beung He; Suh, Soo Jhi [Kosin Medical College, Busan (Korea, Republic of)

    1982-09-15

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst.

  2. Computed tomography using synchrotron radiation

    International Nuclear Information System (INIS)

    X-ray computed tomography (CT) is a widely used method of obtaining cross-sectional views of objects. The high intensity, natural collimation, monochromaticity and energy tunability of synchrotron x-ray sources could potentially be used to provide CT images of improved quality. The advantages of these systems would be that images could be produced more rapidly with better spatial resolution and reduced beam artifacts. In addition, images, in some cases, could be acquired with elemental sensitivity. As a demonstration of the capability of such a system, CT images were obtained of four slices of an excised pig heart in which the arteries and the cardiac chambers were filled with an iodinated medium. Images were taken with incident x-rays tuned successively to energies just above and below the iodine K edge. Iodine specific images were obtained by logarithmically subtracting the low energy image data from the high energy data and then reconstructing the image. CT imaging using synchrotron radiation may become a convenient and non-destructive method of imaging samples difficult to study by other methods

  3. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  4. Computed tomography in late-onset metachromatic leucodystrophy

    International Nuclear Information System (INIS)

    In late-onset metachromatic leucodystrophy (MLD), early clinical diagnosis is difficult since initial symptoms frequently consist of misleading nonspecific psychopathological alterations. On cranial computed tomography (CT), however, symmetrical attenuation decrease of the white matter and mild cerebral atrophy can already be found in an early stage of the disease, and may even precede clinical symptoms. On the basis of observations in four patients with late-onset MLD who were followed between 1 and 5 years, characteristic CT appearances in different stages of the disease are outlined and compared with the literature. (orig.)

  5. FDG positron emission computed tomography in a study of aphasia

    International Nuclear Information System (INIS)

    Positron emission computed tomography (PECT) using 18F-2-fluoro-2-deoxy-D-glucose (FDG) was used to investigate the correlations between clinical status, anatomy (as described by CT), and metabolism in five patients with stable aphasia resulting from ischemic cerebral infarction. Local cerebral metabolic activity was diminished in an area larger than the area of infarction demonstrated by CT. In one patient, FDG PECT revealed a metabolic lesion that probably caused the aphasic syndrome and was not apparent by CT. The data suggest that reliance on CT in delineating the extent of the brain lesion in aphasia or other neuropsychological defects can be misleading; FDG PECT may provide important additional information. Two patients with similar metabolic lesions had very different clinical syndromes, showing that even when currently available methods are combined, major gaps remain in clinicoanatomical correlations in aphasia

  6. Contrast enhancement in computed tomography

    International Nuclear Information System (INIS)

    There appears little question that cerebral contrast enhancement by iodinated material is to a great extent a reflection of a loss of integrity of the blood-brain barrier, expect in those instances where large vascular channels contain a sufficiently large pool of iodinated material of sufficient density and size to be visualized directly. (orig./VJ)

  7. Computed tomography in abnormalities of the hip

    International Nuclear Information System (INIS)

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip join can be measured by means of computed tomography. (Auth.)

  8. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  9. Computed Tomography For Internal Inspection Of Castings

    Science.gov (United States)

    Hanna, Timothy L.

    1995-01-01

    Computed tomography used to detect internal flaws in metal castings before machining and otherwise processing them into finished parts. Saves time and money otherwise wasted on machining and other processing of castings eventually rejected because of internal defects. Knowledge of internal defects gained by use of computed tomography also provides guidance for changes in foundry techniques, procedures, and equipment to minimize defects and reduce costs.

  10. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring;

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  11. Computer tomography of posterior cranial fossa

    Energy Technology Data Exchange (ETDEWEB)

    Sobota, J.; Dutka, J. (Ustredni Vojenska Nemocnice, Prague (Czechoslovakia))

    1982-11-01

    The problems and possibilities are presented of computer tomography examinations of the posterior cranial fossa. The apparatus used was Somatom 2 by Siemens. Such examinations make it possible to introduce specific measurements and evaluations of pathological processes. Computer tomography in itself, however, may not always be successful in this respect and in the examination of the posterior cranial fossa invasive methods, suitably used, will make the diagnosis more accurate and adequate therapy possible.

  12. Computer tomography of posterior cranial fossa

    International Nuclear Information System (INIS)

    The problems and possibilities are presented of computer tomography examinations of the posterior cranial fossa. The apparatus used was Somatom 2 by Siemens. Such examinations make it possible to introduce specific measurements and evaluations of pathological processes. Computer tomography in itself, however, may not always be successful in this respect and in the examination of the posterior cranial fossa invasive methods, suitably used, will make the diagnosis more accurate and adequate therapy possible. (J.O.)

  13. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  14. Brain computed tomography of the hypertensive patients

    International Nuclear Information System (INIS)

    Now a day, hypertension is more increasing in frequency and ranked the top of the causes of death in Korea and other nations. Most of cerebrovascular accidents in hypertensive patients are composed of vascular occlusive changes and hemorrhages. In cerebral angiogram, we can only detect occlusion of large artery and large mass effect from hematoma or cerebral infarction without identification of its entity. The computed tomogram, however, is the best way for evaluation of cerebrovascular diseases including detection of nature, location, amount, and associated changes. This study includes evaluation of computed tomograms of 106 patients with hypertension during the period of 17 months from Feb. 1979 to June 1980 in the department of radiology, college of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 106 patients was broad ranging from 25 years to 76 years. 67.9% of patients were over the age of 50. The male and female sex ratio was 3:2. 2. 28 out of 106 patients were normal and 78 patients revealed abnormal on C. T. findings; those were intracranial hemorrhage (35 patients), cerebral infarction (32 patients) and brain atrophy (11 patients). 3. All of the intracranial hemorrhage except one were intracerebral hemorrhage; those were located in the cerebral hemisphere (19 patients), basal ganglia (15 patients) and brain stem (1 patient). The except one case of intracranial hemorrhage was subdural hematoma. 7 patients of intraventricular hemorrhage and 1 patient of subarachnoid hemorrhage were combined with intracerebral hemorrhage. 2/3 of patients who had hemorrhage in cerebral hemisphere revealed lesions in the parietal and temporal lobes. 4. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (20 cases), and the next was basal ganglia (11 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. The left basal ganglia was more commonly involved

  15. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented

  16. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study*

    OpenAIRE

    Gao, Nuo; Zhu, Shan-an; He, Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types o...

  17. Computed tomography abnormalities in hanging

    International Nuclear Information System (INIS)

    The CT pattern of bilateral and symmetrical round low density areas in the globi pallidi has been observed in a young man who attempted suicide by hanging. These CT abnormalities are similar to those described in other conditions such as carbon monoxide, hydrogen sulfide, cyanide and methanol poisoning, hypoglycaemia, drowning and acute global central nervous system hypoperfusion.The findings appear to be correlated with acute cerebral hypoxia. (orig.)

  18. Studies of cerebral blood flow, cerebral oxygen metabolism, cerebral glucose metabolism, and tissue pH in human acute cerebral infarction using positron emission tomography

    International Nuclear Information System (INIS)

    This preliminary PET study was designed to investigate physiological and biochemical changes in acute cerebral infarction by positron emission tomography (PET). PET studies were performed in six patients with acute cerebral infarction within 48 hours after onset of stroke using continuous inhalation of C15O2 for cerebral blood flow (CBF), 15O2 for cerebral metabolic rate for oxygen (CMRO2), 11CO for cerebral blood volume, the intravenous injection of 11C-dimethyloxazolidinedione for tissue pH and the intravenous injection of 18F-fluorodeoxyglucose for cerebral metabolic rate for glucose (CMRGlu). Metabolic coupling index (MCI) image was made from CBF image and CMRGlu image to investigate relation between CBF and CMRGlu. Aslo oxygen glucose index (OGI) image was made from CMRO2 image and CMRG lu image to investigate relation between CMRO2 and CMRGlu. Preliminary resul ts demonstrate that reduction of CBF, CMRO2, and CMRGlu in the affected co rtex except for reperfusion case. Increase of OER was recognized four of six cases. Patterns of MCI and OGI in the cortex which CMRO2 value is less than 65 μmol/100g/min were different from those in the cortex which CMRO2 value is more than 65. MCI of the affected cortex (CMRO22>=65). OGI of the affected cortex (CMRO22>=65). Two patients showed decrease of tissue pH and reperfusion case showed increase of tissue pH in infarcted area as compared to contralateral cortex. In addition it was suggested that threshold of CBF for tissue pH was approximately 14ml/100g/min. (J.P.N.)

  19. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B;

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...

  20. Computer tomography following blunt abdominal trauma

    International Nuclear Information System (INIS)

    The computer tomographic appearances of lesions of parenchymatous organs following blunt abdominal trauma are described in 13 patients (five liver, four renal, two splenic and two pancreatic injuries). The value of abdominal computer tomography is discussed in relation to the interval between injury and time of abdominal examination and compared with the diagnostic value of abdominal angiography. (orig.)

  1. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  3. Computed tomography in congenital muscular dystrophy (Fukuyama type)

    International Nuclear Information System (INIS)

    Central-nervous system involvement in 26 patients with congenital muscular dystrophy (CMD) was studied using computed tomography (CT). CT was carried out using the EMI-1000 or 1010. The most characteristic finding in the CT was a low-density area in the white matter, seen in 15 out of the 26 (58%). Ventricular dilatation was also noted in 21 out of the 26 (80%), and cortical atrophy in 16 (65%). In one case, asymmetry of the lateral ventricle was observed. Half of the patients had a low-density area in the white matter in addition to cerebral atrophy, while only three (12%) showed normal CT findings. From the relation between the CT findings and IQ in patients with CMD, those with a low-density area in addition to cerebral atrophy and those with cerebral atrophy alone had extremely low IQs compared with those with a low-density area and with normal CT findings. From the relation between the CT findings and the EEG in patients with CMD, seizure discharges, such as a spike or a sharp wave complex and a spike, were most frequently seen in those with a low-density area in the white matter in addition to cerebral atrophy, and among those patients epileptic seizures occurred in three. From the relation between the CT findings and the stage of disability in patients with CMD, those with a low-density area in addition to cerebral atrophy showed severe motor disability. From the relation between CT findings and age in patients with CMD, severe CT findings were seen in the younger group. On ophthalmological examination, one of the most important findings was the evident bulateral optic nerve atrophy noted in several cases. (J.P.N.)

  4. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.)

  5. Cerebral blood flow single-photon emission tomography with 123I-IMP in vascular dementia

    International Nuclear Information System (INIS)

    Cerebral blood flow differences between patients with vascular dementia, patients with multiple lacunar infarction without cognitive dysfunction, and age-matched controls were examined. Thirty four patients with vascular dementia (VD) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All the patients had routine assessment including history, physical and neurological examinations, neuropsychological assessment, blood tests, EEG, head MRI, and single photon emission computed tomography (SPECT). All of them fulfilled the NINDS-AIREN diagnostic criteria for vascular dementia. Thirty nine patients with multiple lacunar infarction without cognitive dysfunction and 110 age-matched controls were included in this study. Mean cerebral blood flow (mCBF) and regional cerebral blood flow (rCBF) were measured using N-isopropyl-P-123I-iodoamphetamine (123I-IMP) and SPECT imager. The mCBF in VD was 27.6±5.3 ml/100 g/min, while those in the control group and multiple lacunar infarction without cognitive dysfunction were 36.6±6.1 ml/100 g/min and 32.5±5.5 ml/100 g/min, respectively. The patients with VD demonstrated significantly reduced mCBF and rCBF in twenty regions including both cerebellar hemispheres as compared with those of the control group. Although there was no significant rCBF differences in bilateral inferior occipital regions and the right cerebellar hemisphere between patients with VD and multiple lacunar infarction without cognitive dysfunction, we could find significant lower rCBF in the remaining brain areas. In spite of the severity of VD, the diffuse decrease of cerebral blood flow was recognized in all patients with VD. (author)

  6. Evaluation of laryngeal carcinoma by computed tomography

    International Nuclear Information System (INIS)

    The limitation of direct or indirect laryngoscopy and laryngogram in determining the exact site and anatomic location of laryngeal carcinoma were well documented by many authors. As compared with laryngoscopy and laryngogram, computed tomographic study for laryngeal cancer is more exact and accurate method demonstrating anatomic sites of involvement, invasion into deep soft tissue spaces of endolarynx, destruction of laryngeal cartilages and cervical metastasis. Fourteen laryngeal cancer patients proven by laryngoscopic biopsy were further examined by computed tomography for staging. The authors compared laryngoscopic findings with those of computed tomography, and their clinical, surgical and computed tomographic findings were analysed. The results were as follows; 1. All patients were proved as squamous cell carcinoma. They were 12 males and 2 females aged over 50 yr. 2. Common clinical symptoms were hoarsense, dysphagia and swallowing difficulty. The primary anatomic sites determined by CT were 8 transglottic, 2 glottic, 2 supraglottic and 1 pyriform sinus respectively. They were 2 T1, 7 T2,1 T3, 3 T4 by TNM systems, respectively. (One case was difficult to evaluate exactly). 3. Invasion into deep soft tissue spaces of endolarynx, cartilage destruction, and neck metastasis were relatively predominant in transglottic carcinomas. 4. Compute tomography was superior in evaluating tumor invasion, especially into deep sift tissue spaces of endolarynx, laryngeal cartilages and metastasis to soft tissue and lymph nodes of neck. However computed tomography had some limitation in determining primary site of laryngeal cancer.

  7. Epiploic appendicitis - ultrasonography and computed tomography findings

    International Nuclear Information System (INIS)

    Epiploic appendicitis is an uncommon inflammatory condition, which is presently better diagnosed by current imaging methods such as computed tomography and ultrasonography that allow a non-invasive and efficient diagnostic approach. The author studied 6 patients with epiploic appendicitis. The patients were submitted to computed tomography that showed paracolic oval lesions of 1 to 2 cm of diameter, fat attenuation and a thin peripheral hyperdense rim associated with adjacent fat stranding. Ultrasound examination performed in two patients showed hyperechoic ovoid noncompressible masses at the site of maximum abdominal tenderness. (author)

  8. Usefulness of computed tomography in recurrent nephrolithiasis

    International Nuclear Information System (INIS)

    For five cases of recurrent stone formers we performed Computed Tomography, which revealed non-visualized small stones on KUB and uric acid stones. Case 1 was primary hyperparathyroidism. Case 2 had several episodes of spontaneous stone passage without any stone shadow on routine X-ray examination. Case 3 had single ureteral stone on X-ray film. Case 4 had several episodes of spontaneous passage of mixed stones (uric acid and calcium oxalate). Case 5 had bilateral radiolucent large renal stones. We emphasized the superiority of Computed Tomography in search and prophylactic therapy of the stone formation. (author)

  9. Computed tomography in spinal canal diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Sobota, J.; Dutka, J. (Ustredni Vojenska Nemocnice, Prague (Czechoslovakia))

    1983-09-01

    On a sample of 128 patients examined for suspected disorders of the spinal canal by computed tomography, the experience with the diagnostic possibilities of this quick, accurate and noninvasive imaging technique is demonstrated. The methodology of the examination and the range of obtained information in diagnosing congenital anomalies, traumas and degenerative changes are briefly described. Certain problems and limitations of this method for the diagnosis of tumors are presented. For the assessment of vascular changes and inflammatory processes, computed tomography cannot be expected to be used on a wider scale.

  10. Computed tomography in spinal canal diagnosis

    International Nuclear Information System (INIS)

    On a sample of 128 patients examined for suspected disorders of the spinal canal by computed tomography, the experience with the diagnostic possibilities of this quick, accurate and noninvasive imaging technique is demonstrated. The methodology of the examination and the range of obtained information in diagnosing congenital anomalies, traumas and degenerative changes are briefly described. Certain problems and limitations of this method for the diagnosis of tumors are presented. For the assessment of vascular changes and inflammatory processes, computed tomography cannot be expected to be used on a wider scale

  11. Multidetector computed tomography angiography of the abdomen

    International Nuclear Information System (INIS)

    Multidetector computed tomography (MDCT) angiography has provided excellent opportunities for advancement of computed tomography (CT) technology and clinical applications. It has a wide range of applications in the abdomen including vascular pathologies either occlusive or aneurysmal; enables the radiologist to produce vascular mapping that clearly show tumor invasion of vasculature and the relationship of vessels to mass lesions. MDCTA can be used in preoperative planning for hepatic resection, preoperative evaluation and planning for liver transplantation. MDCTA can also provide extremely valuable information in the evaluation of ischemic bowel disease, active Crohn disease, the extent and location of collateral vessels in cirrhosis

  12. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.)

  13. Wilson's disease clinical correlation with cranial computed tomography

    International Nuclear Information System (INIS)

    Cranial computed tomograms of 12 patients with proven Wilson's disease were correlated with clinical disturbances. CT abnormalities occurred only in the eight patients with neurological manifestations. The presence of atrophy and low density lesions of the basal ganglia shown on CT correlated well with clinical signs of extrapyramidal dysfunction. Cerebral atrophy and cerebellar cortical atrophy were only moderately related to the degree of intellectual dysfunction and ataxia, respectively; there were no specific clinical signs in cases with brainstem involvement. Abnormalities may be marked in scans taken within a year of neuropsychiatric symptoms, but the most severly abnormal CT scans occurred in patients with a relatively longer duration of untreated disease. Computed tomography provides the opportunity to follow the response of the abnormalities of the brain to cupruresis and can give some assistance in management. (orig.)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are located in ... ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  15. Computed tomography in Minamata disease

    International Nuclear Information System (INIS)

    Nine cases of Minamata disease (MD) were examined by CT scan and the results were compared with those of 40 cases of spinocerebellar degenerations (SCD) and age-matched 70 controls. Forty cases of SCD were classified into 5 types; 9 OPCA, 14 LCCA, 9 cerebellospinal form, 4 hereditary spastic paraplegia, and 4 Friedreich's ataxia according to their clinical manifestations. CTs in MD, compared with those in SCD and normal controls, was characterized as follows; 1) All 9 cases of MD showed a symmetrical ''belt-like'' low density area in bilateral visual cortices with enlargement of posterior horns of the lateral ventricles, corresponding well with the severity of the concentric constriction of visual fields. 2) Three out of 9 MD patients showed a prominent enlargement of cerebral sulci localized around the central sulci. It is strongly suggested that sensory impairment in MD correlates not only with the lesion of the peripheral nerve, but also with that of the sensory cortex. 3) As well as OPCA and LCCA, all 9 cases of MD showed atrophy of the vermis and cerebellar hemispheres. However, prominent enlargement of the cerebellar vallecula was a characteristic pattern in MD. Correlation of cerebellar atrophy with the severity of clinical symptoms, such as dysarthria and incoordination, was not apparent. 4) Atrophy of the brain stem and cerebellar peduncle in MD was mild or slight, in contrast to OPCA which revealed a prominent atrophy of these portions. (J.P.N.)

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  18. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    X-ray computed tomography (CT) is a measuring technique which has become an important technology in the production environment over the last years. Due to a number of advantages of CT compared to, e.g., coordinate measuring machines (CMMs), CT has been recently spread in the field of manufacturin...

  19. Computed Tomography For Inspection Of Thermistors

    Science.gov (United States)

    Schaefer, Lloyd A.

    1991-01-01

    Computed tomography (CT) enables identification of cracked thermistors without disassembly of equipment containing them. CT unit used to scan equipment and locate thermistors. Further scans made in various radial orientations perpendicular to plane of devices to find cracks. Cracks invisible in conventional x-radiographs seen.

  20. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  1. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  2. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir. In...

  3. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  4. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela;

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  5. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  6. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...

  7. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  8. Computed tomography of intussusception in adult

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1984-12-15

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  9. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  10. Computed tomography scanning during a traumatic resuscitation

    NARCIS (Netherlands)

    L.F.M. Beenen; R. Adams; R.W. Koster; T. Otto

    2011-01-01

    In cardiopulmonary resuscitation, computed tomography (CT) imaging could be of decisive importance to therapeutic strategy making but is yet unavailable because of incompatibility of CT scanning and manual chest compressions. In this report, we describe a case in which CT scanning was performed on a

  11. Neutron computed tomography of rat lungs

    International Nuclear Information System (INIS)

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 μm, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  12. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  13. Lung Nodule Detection in Screening Computed Tomography

    CERN Document Server

    Gori, I; Cerello, P; Cheran, S C; De Nunzio, G; Fantacci, M E; Kasae, P; Masala, G L; Pérez-Martínez, A; Retico, A

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

  14. Computed tomography of tuberculous meningitis

    International Nuclear Information System (INIS)

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis. (author)

  15. The diagnostic contribution of computed tomography in intranasal carcinoma with retrobulbar, oral and brain invasion in a canine: case report; Contribuicao da tomografia computadorizada no diagnostico de carcinoma intranasal com invasao retrobular, oral e cerebral em canino: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Zardo, Karen Maciel, E-mail: kmz@bol.com.br; Belotta, Alexandra Frey; Babicsak, Viviam Rocco; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria; Zanoni, Diogo Souza; Costa, Denis Carvalho [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Veterinaria

    2012-07-01

    Intranasal tumors are uncommon and in most cases are malignant, aggressive and with low to moderate potential for metastasis. Clinical signs are usually caused by progressive obstruction of the upper airways. The test cytopathological also is a diagnosis method, but the definitive diagnosis is made by histopathological. Computed tomography (CT) is recommended to treatment planning. A poodle was attended at the veterinary hospital with a clinical history of epistaxis and nasal and ocular secretions, seizures and severe dyspnoea. The animal underwent to radiographic examination of the chest and skull as well as helical computed tomography of the nasal cavity and brain before and after the administration of intravenous contrast. The CT findings revealed an expansive bilateral nasal cavity neoformation, with involvement of the retrobulbar space, right frontal sinus, brain and oral cavity, suggesting a neoplastic or an infectious process. The CT examination allowed the material collection, directly from the mass, to cytological examination, providing the diagnosis of carcinoma. CT also allowed the determination of the unfavorable prognosis of the patient and the treatment planning which not included the surgical excision of the neoformation. Although CT was not conclusive in the diagnosis of carcinoma, it was essential to accurately define the extent of the lesion, to guide the collection of material directly from the tumor and to determine the prognosis of the animal, proving to be an extremely useful tool in cases of tumors intranasal in dogs. (author)

  16. Cranial computerized tomography and cerebral angiography in diagnosis of infarction

    International Nuclear Information System (INIS)

    Discussion of the radiological means to further analysis of the pathogenesis of cerebrovascular alterations up to real stroke with infarction. Today in the first place computer-tomography even with contrast means, moreover in the form of 'angio-CT' are used. Localization, size, form, and the grade of tissue destruction may be analyzed. Furthermore perifocal edema and the stage as also the effect of vascular anastomoses for a collateral circulation may be evaluated. Invasive angiography with puncture of carotid and vertebral arteries is used only in special rare indications. Instead, digital computerized angiography (DSA) can be adopted if particular interest is in the study of intracranial arteries, even with an 'invasive' approach, e.g. by femoral catheter (Seldinger). In summarizing: For the analysis of particular problems radiological methods may assist diagnosis and therapy of cerebrovascular infarct. (orig.)

  17. Cranial computerized tomography and cerebral angiography in diagnosis of infarction

    Energy Technology Data Exchange (ETDEWEB)

    Zuelich, K.J.

    1988-08-05

    Discussion of the radiological means to further analysis of the pathogenesis of cerebrovascular alterations up to real stroke with infarction. Today in the first place computer-tomography even with contrast means, moreover in the form of 'angio-CT' are used. Localization, size, form, and the grade of tissue destruction may be analyzed. Furthermore perifocal edema and the stage as also the effect of vascular anastomoses for a collateral circulation may be evaluated. Invasive angiography with puncture of carotid and vertebral arteries is used only in special rare indications. Instead, digital computerized angiography (DSA) can be adopted if particular interest is in the study of intracranial arteries, even with an 'invasive' approach, e.g. by femoral catheter (Seldinger). In summarizing: For the analysis of particular problems radiological methods may assist diagnosis and therapy of cerebrovascular infarct.

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... child may have, and if there is a history of heart disease, asthma, diabetes, kidney disease or ... the patient. The computer that processes the imaging information and monitor are ... in detector technology allow new CT scanners to obtain multiple slices ...

  19. Use of Electrical Impedance Tomography to Monitor Regional Cerebral Edema during Clinical Dehydration Treatment

    OpenAIRE

    Fu, Feng; Li, Bing; Dai, Meng; Hu, Shi-Jie; Li, Xia; Xu, Can-Hua; Wang, Bing; Yang, Bin; Tang, Meng-Xing; Dong, Xiu-Zhen; Fei, Zhou; Shi, Xue-Tao

    2014-01-01

    Objective Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. Design a prospective study. Setting In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical ...

  20. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  1. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blery, M.; Hautefeuille, P.; Jacquenod, P. and others

    1987-09-01

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses.

  2. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses

  3. Signs of cerebral atrophy on single-photon emission tomography

    International Nuclear Information System (INIS)

    In this retrospective study, we describe and evaluate criteria for the diagnosis of cerebral atrophy on technetium-99m hexamethylpropylene amine oxime brain SPET studies. The SPET scans of 11 patients with cerebral atrophy and ten controls were evaluated for the presence of a prominent interhemispheric fissure, presence of prominent cerebral sulci, separation of thalamic nuclei, and pronounced separation of caudate nuclei. The SPET studies were interpreted by two independent observers blind to the findings of magnetic resonance imaging, which provided the final diagnosis of cerebral atrophy. The combination of the four scintigraphic signs was accurate in the diagnosis of cerebral atrophy in 95% of the cases and had a sensitivity of 91% and a specificity of 100%. (orig./MG)

  4. Signs of cerebral atrophy on single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wong, C.O. (Johns Hopkins Medical Institutions, Div. of Nuclear Medicine, Baltimore, MD (United States)); Meyerrose, G.E. (Johns Hopkins Medical Institutions, Div. of Nuclear Medicine, Baltimore, MD (United States)); Sostre, S. (Johns Hopkins Medical Institutions, Div. of Nuclear Medicine, Baltimore, MD (United States))

    1994-05-01

    In this retrospective study, we describe and evaluate criteria for the diagnosis of cerebral atrophy on technetium-99m hexamethylpropylene amine oxime brain SPET studies. The SPET scans of 11 patients with cerebral atrophy and ten controls were evaluated for the presence of a prominent interhemispheric fissure, presence of prominent cerebral sulci, separation of thalamic nuclei, and pronounced separation of caudate nuclei. The SPET studies were interpreted by two independent observers blind to the findings of magnetic resonance imaging, which provided the final diagnosis of cerebral atrophy. The combination of the four scintigraphic signs was accurate in the diagnosis of cerebral atrophy in 95% of the cases and had a sensitivity of 91% and a specificity of 100%. (orig./MG)

  5. Real-time computed optical interferometric tomography

    Science.gov (United States)

    Shemonski, Nathan D.; Liu, Yuan-Zhi; Ahmad, Adeel; Adie, Steven G.; Carney, P. Scott; Boppart, Stephen A.

    2014-03-01

    High-resolution tomography is of great importance to many areas of biomedical imaging, but with it comes several apparent tradeoffs such as a narrowing depth-of-field and increasing optical aberrations. Overcoming these challenges has attracted many hardware and computational solutions. Hardware solutions, though, can become bulky or expensive and computational approaches can require high computing power or large processing times. This study demonstrates memory efficient implementations of interferometric synthetic aperture microscopy (ISAM) and computational adaptive optics (CAO) - two computational approaches for overcoming the depthof- field limitation and the effect of optical aberrations in optical coherence tomography (OCT). Traditionally requiring lengthy post processing, here we report implementations of ISAM and CAO on a single GPU for real-time in vivo imaging. Real-time, camera-limited ISAM processing enabled reliable acquisition of stable data for in vivo imaging, and CAO processing on the same GPU is shown to quickly correct static aberrations. These algorithmic advances hold the promise for high-resolution volumetric imaging in time-sensitive situations as well as enabling aberrationfree cellular-level volumetric tomography.

  6. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  7. Computed tomography of the medulla

    International Nuclear Information System (INIS)

    The medulla was studied in cadavers and in 100 patients both with and without the intrathecal administration of contrast material. The computed tomographic (CT) anatomy was correlated with the appearance on anatomic dissections. The pyramids, olives, and inferior cerebellar peduncles produced characteristic contours on cross sections of the medulla. The hypoglossal nerve by its location and course in the medullary cistern could be distinguished from the glossopharyngeal, vagal, and spinal accessory nerves. For optimal evaluation of the medulla, intrathecal administration of metrizamide and 5- and/or 1.5-mm-thick axial and coronal sections are recommended

  8. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  9. Computed tomography in Krabbe's disease: Comparison with neuropathology

    International Nuclear Information System (INIS)

    We report computed tomography (CT) appearance of two patients with Krabbe's disease. The most common findings included severe brain atrophy: en enlarged frontal extracerebral space, dilatation of ventricles, enlarged cisterns and enlarged cortical sulci. There was low attenuation in the corpus medullaris of the cerebellum, and symmetrical focal hypodensity in the central periventricular white matter. CT at the terminal stage (16 months) showed marked cerebral atrophy including flattening of the heads of caudate nuclei and widening of the third ventricles confirmed by a neuropathological study. There was relatively less low density on the white matter of Krabbe's disease compared with that of other leukodystrophies. These CT findings may be useful in the diagnosis. The relative lack of low density in the white matter of Krabbe's disease might be related to severe gliosis and reduced total lipid contents. (orig.)

  10. The protocol of dose reduction in liver perfusion computed tomography

    International Nuclear Information System (INIS)

    Cerebral perfusion computed tomography (CT) has been widespread, but abdominal perfusion CT has not been very popular because there has been a problem with regard to the limit of irradiation range and respiratory effects. Recently, it became easy to perform perfusion of abdominal organs because the use of multi detector row CT (MDCT) has been extensive. Along with it, the number of hospitals that perform liver perfusion CT has increased. However, patient dose of the liver perfusion CT is very high, making it very important to reduce patient dose. We created the virtual data that reduced the number of irradiation by partly reducing the data obtained on the liver perfusion CT. We compared the analysis results of all data with that of the partly reduced. It is possible to reduce the patient dose by reducing the number of irradiation because there was no significant difference in the analysis results. (author)

  11. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  12. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis. (author)

  13. Inflammatory disease of the brain diagnosed by computed tomography

    International Nuclear Information System (INIS)

    Inflammatory disease of the brain, particularly of pyogenic etiology, may be most accurately assessed by the use of computed tomography and contrast enhancement. Examples of cerebritis, evolving and mature intracerebral abcesses, and inflammatory extracerebral collections are presented and discussed, particularly with reference to differential diagnosis and the problem of infectious versus neoplastic etiology. Ancillary studies, particulary selective arteriography, are reviewed where appropriate. The residual changes of inflammatory disease of the brain after medical and/or surgical therapy are illustrated, and the value of serial examinations is emphasized. The rural indigent patient population (American Indian) served by the University of New Mexico Medical Center is a source of case material providing several examples of severe and untreated intracerebral infectious processes heretofore not described in the literature. (orig.)

  14. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect...

  15. Practical management of computed tomography

    International Nuclear Information System (INIS)

    For examinations of the spinal canal is used computed myelography as an adjunct to water-soluble conventional myelography. For CT alone about 3.5 g. of metrizamide in isotonic solution is adequate for all investigations. If the constrast medium has to be run into the head by gravity, as in the detection of cerebrospinal fluid fistula or empty sella, or for detailed examination of the basal cisterns, phenobarbitone 100 mg. t.d.s. is commenced on the eve of the examination and continued for 48 hours. A similar dose is also administered to epileptic subject. If fits should occur they are treated with intravenous diazepam and prophylactic phenobarbitone is administered. (orig./AJ)

  16. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    International Nuclear Information System (INIS)

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma

  17. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  18. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  19. Biliary obstruction: Helical computed tomography cholangiography evaluation

    International Nuclear Information System (INIS)

    Helical computed tomography cholangiography (HCTC) takes advantage of the improvement in the quality of multiplanar and three-dimensional reconstructions resulting from the volumetric acquisition of data achieved with helical computed tomography and the indirect opacification of the bile ducts provided by cholangiographic contrast media. This method was used to evaluate 31 patients with suspected biliary obstruction over a one-year period and the findings were compared with those of direct cholangiography and/or surgery. Biliary opacification was sufficient to allow three-dimensional reconstructions in 90,3% of cases. Sensitivity was 81% for the diagnosis of choledochoolithiasis and 100% for ascariasis, choledochal cysts and anatomic variants of the biliary tree. Our results indicate that HCTC is a valuable alternative as a diagnostic method prior to direct cholangiography. Direct cholangiography should be reserved for those patients who require it as part of a therapeutic procedure

  20. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  1. Computed tomography of ano-rectal anomalies

    International Nuclear Information System (INIS)

    Computed tomography (CT) was performed in 9 patients with faecal incontinence more than 8 years after rectoplasty for high imperforate anus. The radiologic findings were correlated with the clinical evaluation of faecal incontinence. No statistically significant correlation was found between function and anatomic findings as demonstrated by CT. Thus, although CT demonstrates the post-operative anatomy in a detailed way, the information does not seem to be directly applicable when selecting the type of reoperation for faecal incontinence. (orig.)

  2. Dose reduction in abdominal computed tomography

    International Nuclear Information System (INIS)

    The broad availability and use of multidetector computed tomography (MDCT) in recent years has increased the radiation dose for patients. Multiphase MDCT protocols are used in abdominal imaging for various indications. Dose reduction though novel technologies, such as dual energy CT or adapted contrast injection protocols (split bolus etc.) for reduction of scans. An optimized dose reduction can be achieved by using strict protocols which are adapted to the clinical situation of the patient. (orig.)

  3. Computed tomography diagnostic of chronic rhino sinusitis

    International Nuclear Information System (INIS)

    Ordinary conventional roentgenological examinations of paranasal sinuses does not satisfy the latest needs of otorinolaringologysta, especially for functional endoscopic surgery. Computed tomography of paranasal sinuses because more important for diagnostics of chronic rhino sinusitis and for choosing the appropriate therapy of it. The examination enables to localize pathology precisely, to exactly evaluate anatomic structures, ostiomeatalic complex, the status of mucous membrane of paranasal sinuses and the effectiveness of surgical treatment of chronic rhino sinusitis. (author)

  4. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  5. Computed Tomography Findings in Xanthogranulomatous Pyelonephritis

    OpenAIRE

    Arumugam Rajesh; George Jakanani; Nick Mayer; Kevin Mulcahy

    2011-01-01

    Background: Xanthogranulomatous pyelonephritis (XGN) is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. Purpose: To review the computed tomography (CT) findings of patients diagnosed with XGN. Materials and Methods: A retrospective review of CT findings in patients with histologically proven XGN was carried out. Results: Thirteen CT examinations of 11 patients were analyzed. Renal enlargement was demonstrable on ...

  6. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  7. Computed tomography in gastrointestinal stromal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias [Department of Diagnostic Radiology, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany); Furtwaengler, Alex [Department of Abdominal Surgery, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany)

    2003-07-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (<5 cm) showed a sharp tumor margin with homogeneous density and structure on unenhanced and contrast-enhanced images, and were characterized by an intraluminal tumor growth. Intermediate sized GIST (>5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography

  8. Analysis of computed tomography of ovarian tumor

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Makoto; Taniike, Keiko; Nishiguchi, Hiroyasu

    1987-07-01

    One hundred and twenty six patients with ovarian mass were studied with computed tomography (CT) and classified into five groups according to its margin and inner structure. The incidence of malignancy of cystic ovarian mass with smooth margin was low and that of solid ovarian mass with irreglar margin was high. Three cases (6.7 %) of malignant ovarian tumor demonstrated completely cystic pattern. Ovarian teratomas contained well defined component of fat density.

  9. Improvement in computed tomography spatial resolution

    International Nuclear Information System (INIS)

    One of the most important recent developments in transmission computed tomography is the improvement in spatial resolution. Applications of this technical advance to the neuroradiographic exploration of such structures as spinal cord, nerve roots and pituitary gland - as well as the orbits and inner and middle ear - is still limited to a few centers. Increased spatial resolution appears to be an effective means to increase our diagnostic capabilities. The higher dosimetry connected with this modality needs to be emphasized. (orig.)

  10. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  11. HORSESHOE KIDNEY: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2015-06-01

    Full Text Available Background and Objective: Horseshoe kidney is the most common renal fusion anomaly with a reported prevalence of 1 in 400 persons with a male to female ratio of 2:1. In many cases its presence may go unnoticed and undiagnosed because the patient may remain asymptomatic throughout life. The objective of our study is to report radiological and anatomical features of horseshoe kidney detected incidentally during retrospective evaluation of multidetector computed tomography scans. Materials and Methods: Contrast enhanced multidetector computed tomography scans of 682 patients, 355 males and 327 females, were reviewed retrospectively. Results: Seven cases of horseshoe kidney were detected incidentally, six males and one female, with an incidence of 1.02 %. In all cases, malrotation of the kidneys were observed with the hilum facing anteriorly or anterolaterally. The isthmus was made up of parenchymal tissue in all the cases and the fusion was midline in four cases and lateral in three cases. Horseshoe kidney in all cases was supplied by multiple renal arteries, varying from 3 to 6. In three cases symmetrical arterial supply and in the rest asymmetrical supply was observed. Nephrolithiasis and hydronephrosis were noted in two patients. No other associated congenital anomaly was observed in all seven patients. Conclusion: Contrast enhanced multidetector computed tomography evaluation of patients with horseshoe kidney provide excellent information about its vascularity, collecting system and other associated conditions.

  12. Metabolic and circulatory evaluation of acute cerebral ischaemic accidents in man by positron emission tomography

    International Nuclear Information System (INIS)

    Positron emission tomography and oxygen-15 were used to evaluate the effects of an almitrine-raubasine combination on cerebral blood flow and oxydative metabolism in patients with acute cerebral ischaemia. In 5 patients, aged between 58 and 74 years, with cerebral ischaemic accident in the territory of the middle cerebral artery, blood flow rate, oxygen consumption and brain oxygen extraction were measured before and after a 90-min intravenous infusion of almitrine bismesilate 15 mg and raubasine 5 mg. Only one patient presented with initial relative luxury perfusion, the intensity of which was reduced by the combined treatment. The other 4 patients had focal reduction of cerebral blood flow and oxygen consumption prior to treatment. Satistical analysis conducted on three cerebral areas (epicentre of the lesion, anterior and posterior juxtalesional areas and homologous heterolateral areas) showed a significant 3.6% increase of oxygen consumption in the epicentre, both hemispheres included, and a significant increase of cerebral blood flow in all three areas (3% on the healthy side, 13% on the diseased side). No significant change in oxygen extraction was demonstrated. The authors conclude that acute almitrine-raubasine treatment has beneficial effects on the brain immediately after a cerebral vascular accident, reflecting respect of the circulation-metabolism couple

  13. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik;

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment of...

  14. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    International Nuclear Information System (INIS)

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [15O]H2O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  15. Brain abscess in a Japanese Black calf: Utility of computed tomography (CT)

    International Nuclear Information System (INIS)

    Computed tomography (CT) was used for diagnosis of brain abscess in a 6-month-old, Japanese Black calf presented with neurological dysfunction, compulsive circling and vision disturbance. CT images showed asymmetric lateral ventricles, and presence of intra-cranial multiple low absorption lesions surrounded by capsule suggestive of abscess in the right cerebral hemisphere. Postmortem examination revealed marked swelling of right cerebral hemisphere and olfactory bulb. Multilocular large abscess containing creamy pus was found to occupy most area of periventricular and lateral ventricle. Fusobacterium necrophrum was isolated from the abscess contents as the causative agent. These results demonstrate that CT is useful tool for tentative diagnosis of bovine brain abscess

  16. Single photon emission computed tomography in periatric frontal epilepsy

    International Nuclear Information System (INIS)

    Neuroradiological examinations were made in 9 pediatric patients with frontal epilepsy by using single photon emission computed tomography (SPECT), cat scanning (CT) and magnetic resonance imaging (MRI). Two patients (22%) had abnormal findings on both CT and MRI; and 6 patients (67%) had them on SPECT, two of whom had findings corresponding to focal sites on EEG. Among the 6 patients, 5 were suspected of having decreased regional cerebral blood flow (rCBF), corresponding to 84%-94% of the contralateral blood flow. Two patients were evaluable before and after seizures; one had increased rCBF at the time of frequent seizures and returned to normal after seizures; and the other had no abnormality in the early stage of epilepsy, but had decreased rCBF after seizures. SPECT appears to provide a simple, useful tool in evaluating cerebral hemodynamics in infantile epilepsy, although serial hemodynamic changes with developmental process of central nerves and the time of examination must be considered according to individual patients. (N.K.)

  17. ROLE OF COMPUTED TOMOGRAPHY IN CERBROVASCULAR ACCID ENT

    Directory of Open Access Journals (Sweden)

    Kalra

    2013-02-01

    Full Text Available ABSTRACT: Cerebrovascular accident is characterized by the s udden loss of blood circulation to an area of the brain resulting in a corresponding lo ss of neurologic function. Stroke is mainly of two types ischaemic or haemorrhagic and differentiat ion is important as the management differs substantially with the type of stroke. Aim o f the study was to compare the clinical diagnosis with computed tomography diagnosis and to d ifferentiate between the types of stroke. The study included 90 clinically suspected patients o f stroke who underwent CT imaging at Konaseema Institute of Medical Sciences, Amalapur am, A.P. from July,2009 to September,2011.The incidence of CVA was significantl y higher in males than females (73.3% n=66 vs 26.6% n=24.The most frequently affected a ge group was 50 to 69Years of age(67%The incidence of ischaemic stroke was signi ficantly higher than haemorrhagic stroke both in males and females. The most common localizations were parietal and fron tal lobe. The middle cerebral artery followed by the anterior cerebral artery we re the commonest vascular territories affected. The sensitivity of clinical diagnosis remained 90%. But clinical diagnosis is not dependable for therapeutic & prognostic purpose when pla nning for anti-coagulation or thrombotic therapy.

  18. Computed tomography in the management of cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    The radiological technique of computed tomography (CT) used in neurological diagnosis of vascular diseases of the brain is explained, and its application to specific clinical situations is described. Cerebral infarcts of varying ages can be visualized, with a recent ischemic infarct appearing as a region of decreased density. Hemorrhagic infarcts in acute and subacture stages also can be visualized, and the advantage to the patient is that the procedure is virtually without risk. CT is the procedure of choice in confirming a diagnosis of hemorrhage into the brain parenchyma or into the ventricular system. Hematomas not readily detectable by conventional angiography may be demonstrated by CT, particularly if they are large. Cerebral aneurysms and arteriovenous malformations cannot be detected by CT unless calcification or clotted blood is present. However, several radiologists have noted enhancement of the diagnostic capability for both neoplasms and vascular lesions such as aneurysms and AV malformations, when an intravenous infusion of angiographic contrast material is started prior to the scan. It is noted that considerable technical skill is required to keep CT equipment operating properly, and photographs of scans may be made a part of the patients's clinical record. An attachment to this document corrects an error on a previous technical assistance memorandum. (GRA)

  19. Hyperperfusion on Perfusion Computed Tomography Following Revascularization for Acute Stroke

    International Nuclear Information System (INIS)

    Purpose: To describe the findings of hyperperfusion on perfusion computed tomography (CT) in four patients following revascularization for acute stroke. Material and Methods: In 2002-2003, among a series of 6 patients presenting with an acute stroke and treated with intra-arterial thrombolysis, we observed the presence of hyperperfusion in 3 patients on the follow-up CT perfusion. We included an additional patient who was treated with intravenous thrombolysis and who had hyperperfusion on the follow-up CT perfusion. We retrospectively analyzed their CT perfusion maps. Cerebral blood volume (CBV) and cerebral blood flow (CBF) maps were compared between the affected territory and the normal contralateral hemisphere. Results: In the four patients, the mean CBV and CBF were 3.6±2.0 ml/100 g and 39±25 ml/100 g/min in the affected territory compared to the normal side (mean CBV 2.7±2.1 ml/100 g, mean CBF = 27±23 ml/100 g/min). There was no intracranial hemorrhage in the hyperperfused territories. At follow-up CT, some hyperperfused brain areas progressed to infarction, while others retained normal white to gray matter differentiation. Conclusion: CT perfusion can demonstrate hyperperfusion, which can be seen in an ischemic brain territory following recanalization

  20. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  1. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    This study was designed to rate the clinical value of [123I]iodoamphetamine (IMP) or [99mTc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [123I]IMP or [99mTc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  2. Single photon emission computed tomography-guided Cerenkov luminescence tomography

    Science.gov (United States)

    Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie

    2012-07-01

    Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.

  3. Single photon emission computed tomography using 99Tcm-HMPAO in Alzheimer's disease

    International Nuclear Information System (INIS)

    Brain single photon emission computed tomography (SPET) using 99mTcm-hexamethylpropyleneamine oxime (HMPAO) was performed in 37 patients satisfying standard clinical criteria of Alzheimer's disease (AD), correlating results with patient's age of onset, duration of illness, severity of dementia, neuropsychological impairment, computed tomography (CT) and EEG findings. All had abnormal SPET: 23 were bilaterally symmetric, 10 bilaterally asymmetric and four showed unilateral low regional cerebral perfusion. Low perfusion in bilateral parietal regions was the most consistent finding and was present alone or with other abnormal regions in 31 patients (84%). The only significant clinical correlation was found between asymmetric SPECT changes and onset of disease before the age of 65 years. 50% of patients with presenile onset, but only 19% with senile onset had asymmetric low regional cerebral perfusion. Fifteen of the 36 patients had normal brain CT scans, and 9 of 31 patients receiving EEG examination had normal results. (author)

  4. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  5. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  6. Fluorescence Computed Tomography with Polychromatic Source Data

    International Nuclear Information System (INIS)

    Fluorescence computed tomography is a synchrotron imaging technique aiming at reconstructing the fluorescence emission within a sample object. For a polychromatic source hitting the object, the amount of fluorescence detected is defined by a linear equation. For the monochromatic case, the operator is a Generalized Attenuated Radon Transform (GART). The main goal is to reconstruct the density function, given the sinogram data and the weight function. An eficient iterative algorithm for the inversion of the GART was presented recently by the authors. This inversion can only be performed if the weight function is previously known, which means that μ = μ(·, ε) and λ are also known. For monochromatic XFCT (acronym for x-rays fluorescence computed tomography), the determination of λ is a dificult task, and we have considered the approximation λ ≈ μ, which is valid for low energies ranging from 3Kev to 10Kev. So, for solving our problem, the first step is to find μ given the polychromatic sinogram. There are different approaches for this in the literature. Recently, an elegant and efficient method for solving this problem was introduced, using a fixed point algorithm. Opposite to this, where μ(·, ε) needs to be computed for all ε element of E, we claim that the integral of μ(·, ε) for all ε has a physical meaning and provides a good aproximation for the solution. Also we present fast algorithm for computations.

  7. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  8. Diagnostic value for extrahepatic metastases of hepatocellular carcinoma in positron emission tomography/computed tomography scan

    OpenAIRE

    2012-01-01

    AIM: To evaluated the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) scan in diagnosis of hepatocellular carcinoma (HCC) and extrahepatic metastases.

  9. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-09-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients.

  10. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    International Nuclear Information System (INIS)

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients

  11. Computed tomography of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Computed tomography (CT) was performed on five infants with hepatic hemangioendothelioma. Precontrast scans showed solitary or multiple, homogeneous, circumscribed areas with reduced attenuation values. Tiny tumoral calcifications were identified in two patients. Serial scans, after injection of a bolus of contrast material, showed early massive enhancement, which was either diffuse or peripheral. On delayed scans, multinocular tumors became isodense with surrounding liver, while all solitary ones showed varied degrees of centripetal enhancement and persistent central cleftlike unenhanced areas. The authors believe that these CT features are characteristic and obviate arteriographic confirmation

  12. Multidetector Computed Tomography in Acute Joint Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Haapamaeki, V.V.; Kiuru, M.J.; Mustonen, A.O.; Koskinen, S.K. [Helsinki Univ. Central Hospital (Finland). Helsinki Medical Imaging Center

    2005-10-01

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement.

  13. Quantitative computed tomography in assessment of osteoporosis

    International Nuclear Information System (INIS)

    Osteoporosis is a common disorder with considerable health risk and medical care cost. Recent advances in technology have provided new opportunities for evaluating bone mass noninvasively that may impact substantially on the detection and course of osteoporotic conditions. The laboratory and clinical results presented herein indicate that quantitative computed tomography provides a reliable means to evaluate and monitor the many forms of osteoporosis and the various interventions aimed at ameliorating this condition. The greatest advantages of spinal QCT for noninvasive bone mineral measurement lie in the high precision of the technique, the high sensitivity of the vertebral spongiosa measurement site, and the potential for widespread application

  14. Multidetector Computed Tomography in Acute Joint Fractures

    International Nuclear Information System (INIS)

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement

  15. Computed tomography of cardiac pseudotumors and neoplasms.

    Science.gov (United States)

    Anavekar, Nandan S; Bonnichsen, Crystal R; Foley, Thomas A; Morris, Michael F; Martinez, Matthew W; Williamson, Eric E; Glockner, James F; Miller, Dylan V; Breen, Jerome F; Araoz, Philip A

    2010-07-01

    Important features of cardiac masses can be clearly delineated on cardiac computed tomography (CT) imaging. This modality is useful in identifying the presence of a mass, its relationship with cardiac and extracardiac structures, and the features that distinguish one type of mass from another. A multimodality approach to the evaluation of cardiac tumors is advocated, with the use of echocardiography, CT imaging and magnetic resonance imaging as appropriately indicated. In this article, various cardiac masses are described, including pseudotumors and true cardiac neoplasms, and the CT imaging findings that may be useful in distinguishing these rare entities are presented. PMID:20705174

  16. Computed tomography after percutaneous renal stone extraction

    International Nuclear Information System (INIS)

    Eighty patients were examined with computed tomography (CT) of the kidney and the retroperitoneal space after percutaneous stone extraction. Most examinations were done within a week after the operation. The morphologic changes were usually small or none. In 7 patients minor renal or perirenal fluid collections were found. Their operations had been complicated by bleeding or leakage. In 66 patients CT was compared with conventional radiographs. Residual stones were more often detected by CT. They were usually small. Percutaneous renal stone extraction is considered a safe and efficient method. (orig.)

  17. Computed tomography studies of human brain movements

    International Nuclear Information System (INIS)

    Rhythmic brain movements have been revealed by sets of sequential computed tomography scans of human brains (seen retrospectively to be normal). These scans have shown that both (unenhanced) brain parenchymal density and the shapes of the elements of the supratentorial ventricular/cisternal system are subject to wave motions having similar periods - ranging from 26 s through 56 s, 77-96 s, 109 s and 224 s to 224 X 2 s (or even longer), with good correlation between peak values. These motions, as well as phase variations between the waves, suggest a peristaltic movement of cerebrospinal fluid through the ventricular/cisternal system with progressive axial damping

  18. Calculation of profitability in computer tomography (CT)

    International Nuclear Information System (INIS)

    The comments do not refer to a specific type of whole body computer tomography which made it necessary to base the calculations on mean values with regard to both initial costs and operating costs. The calculation of the receipts was based on the resulting costs, mean long-term utilization of the unit and on a reasonable period of amortization. The model calculation indicates that the break-even point is reached with 1,920 annual examinations and a five-year amortization period. (orig.) 891 MG/orig. 892 MB

  19. Emerging clinical applications of computed tomography

    Directory of Open Access Journals (Sweden)

    Liguori C

    2015-06-01

    Full Text Available Carlo Liguori,1 Giulia Frauenfelder,2 Carlo Massaroni,3 Paola Saccomandi,3 Francesco Giurazza,4 Francesca Pitocco,4 Riccardo Marano,5 Emiliano Schena,3 1Radiology Unit, AORN A Cardarelli, 2Radiology Unit, AOU Federico II, Naples, 3Measurement and Biomedical Instrumentation Unit, 4Radiology Unit, Università Campus Bio-Medico di Roma, 5Department of Radiological Sciences, Institute of Radiology, Catholic University of Rome, A Gemelli University Hospital, Rome, Italy Abstract: X-ray computed tomography (CT has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications. Keywords: computed tomography, X-ray, thermometry, dual-energy, ultrafast scanner, guidance, photon-counting technology

  20. Microscopic x-ray luminescence computed tomography

    Science.gov (United States)

    Zhang, Wei; Zhu, Dianwen; Zhang, Kun; Li, Changqing

    2015-03-01

    X-ray luminescence computed tomography (XLCT) was emerged as a new hybrid imaging modality, in which the x-rays are used to excite phosphors emitting optical photons to be measured for imaging. In this paper, we reported a microscopic x-ray luminescence computed tomography (microXLCT) with a spatial resolution up to hundreds of micrometers for deep targets. We use a superfine x-ray pencil beam to scan the phosphor targets. The superfine x-ray pencil beam is generated by a small collimator mounted in front of a powerful x-ray tube (93212, Oxford Instrument). A CT detector is used to image the x-ray beam. We have generated an x-ray beam with a diameter of 192 micrometers with a collimator of 100 micrometers in diameter. The emitted optical photons on the top surface of phantom are reflected by a mirror and acquired by an electron multiplier charge-coupled device (EMCCD) camera (C9100-13, Hamamatsu Photonics). The microXLCT imaging system is built inside an x-ray shielding and light tight cabinet. The EMCCD camera is placed in a lead box. All the imaging components are controlled by a VC++ program. The optical photon propagation is modeled with the diffusion equation solved by the finite element method. We have applied different regularization methods including L2 and L1 in the microXLCT reconstruction algorithms. Numerical simulations and phantom experiments are used to validate the microXLCT imaging system.

  1. Computed tomography colonography (virtual colonoscopy): review

    International Nuclear Information System (INIS)

    Computed tomography examination of the colon performed after bowel cleansing and distension of the lumen with gas goes by several different names-CT colonography (CTC) and CT colography perhaps being the most common. Strictly, the term 'virtual colonoscopy' (VC), should be reserved for the process of examining 3-D, simulated endo-luminal images with a capability to navigate through the bowel using appropriate software. Computed tomography colonography appears to be the name that has gained favour among radiologists, although it is suspected that 'virtual colonoscopy' will persist as a generic term due to its attractive 'high-tech' connotations for non-radiological medical and lay persons. Whatever the name, the technique has been made possible through the advent of fast helical CT scanners which allow acquisition of a volume of data, and of proprietary software which enables multiplanar reformatting and 3-D endoluminal reconstructions. It is evident that if CTC/VC can be shown to be acceptable to patients, safe, affordable and accurate, it has enormous potential as a diagnostic and screening tool for colorectal neoplasia. Copyright (2002) Blackwell Science Pty Ltd

  2. Computed tomography of juvenile nasopharyngeal angiofibroma

    International Nuclear Information System (INIS)

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma

  3. Computed tomography in suppurative meningitis. CT and clinical findings in the acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Akira; Fujiwara, Katsuhiko; Iino, Shigeru (Kyoto Prefectural Univ. of Medicine (Japan))

    1982-06-01

    Computed tomography abnormalities revealed in 18 of 29 patients (62%) with infantile supprative meningitis. The abnormalities included ventricular dilatation (12 cases), subdural edema (8), cerebral infarction (4), cerebral atrophy (3), encephalitis (2), and cerebral herniation (1). The comparative study of CT pictures and clinical findings in the acute stage of the disease showed that the high incidence of these abnormalities occurred in the following conditions: 1) The age was less than 1 year, 2) establishment of the diagnosis took more than 5 days, 3) glucose of the cerebrospinal fluid was less than 200 mg/dl, 4) protein of the cerebrospinal fluid was more than 200 mg/dl, and 5) convulsion occurred 24 hrs after institution of the treatment.

  4. Computed tomography of post-traumatic orbito-palpebral emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Nose, H.; Kohno, K. (Tsukuba Univ., Sakura, Ibaraki (Japan))

    1981-11-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema.

  5. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  6. Persistence of cerebral metabolic abnormalities in chronic schizophrenia as determined by positron emission tomography

    International Nuclear Information System (INIS)

    Local cerebral metabolic rates were determined by positron emission tomography and the deoxyglucose method in a group of 10 chronic schizophrenic subjects before and after somatic treatment and in eight normal subjects. Before treatment, schizophrenic subjects had markedly lower absolute metabolic activity than did normal controls in both frontal and temporal regions and a trend toward relative hyperactivity in the basal ganglia area. After treatment, their metabolic rates approached those seen in normal subjects in nearly all regions except frontal. Persistence of diminished frontal metabolism was manifested as significant relative hypofrontality. These findings suggest specific loci of aberrant cerebral functioning in chronic schizophrenia and the utility of positron emission tomography in characterizing these abnormalities

  7. Cerebral blood flow imaged with ultrahigh-resolution optical coherence angiography and Doppler tomography

    OpenAIRE

    Ren, Hugang; Du, Congwu; Pan, Yingtian

    2012-01-01

    Speckle contrast based optical coherence angiography (OCA) and optical coherence Doppler tomography (ODT) have been applied to image cerebral blood flow previously. However, the contrast mechanisms of these two methods are not fully studied. Here, we present both flow phantom and in vivo animal experiments using ultrahigh-resolution OCA (μOCA) and ODT (μODT) to investigate the flow sensitivity differences between these two methods. Our results show that the high sensitivity of μOCA for visual...

  8. Comparison of mean cerebral transit time and single-photon emission tomography for estimation of stroke outcome

    Energy Technology Data Exchange (ETDEWEB)

    Lees, K.R. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom); Weir, C.J. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom)]|[Robertson Centre for Biostatistics, University of Glasgow (United Kingdom); Gillen, G.J. [Department of Nuclear Medicine, Western Infirmary, Glasgow (United Kingdom); Taylor, A.K. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Ritchie, C. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom)]|[Department of Occupational Therapy, West Glasgow Hospitals University NHS Trust, Glasgow (United Kingdom)

    1995-11-01

    This study aimed to compare the effectiveness of SPET and mean cerebral transit time (MCTT) in the prediction of functional outcome. Sixty-three patients undergoing cerebral computed tomography (CT), technetium-99m MCTT, and technetium-99m-labelled hexamethylpropylene amine oxime SPET soon after acute ischaemic stroke had outcome assessed after 3 months. Cerebral CT, SPET and MCTT scans were interpreted without reference to the clinical data; a single independent observer assessed outcome using the Barthel Index. The 3-month Barthel score in survivors was significantly correlated with volume of lesion on SPET and with the ratio of mean affected hemisphere transit times to mean unaffected hemisphere transit times, but not with CT lesion volume. Stepwise logistic regression identified volume of lesion on SPET as the only significant predictor of good functional outcome. The overall predictive accuracy was 73%. It is concluded that MCTT, although significantly correlated with functional outcome, failed to predict good functional recovery in individual stroke survivors. Since SPET provides more detailed localisation of perfusion deficits, and since SPET lesion volume can be used to predict functional outcome, SPET remains preferable to MCTT when perfusion imaging is required. (orig./MG)

  9. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study

    Institute of Scientific and Technical Information of China (English)

    GAO Nuo; ZHU Shan-an; HE Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach.Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%,for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.

  10. Evaluation of results for computed tomography in head region

    International Nuclear Information System (INIS)

    In 2 years and 5 months from April 1980 to May 1982, I had maked examination for computed tomography (CT) in head region by TCT-60A (TOSHIBA), and so reported the evaluation of following those results; 1) The number of CT scan was 1228 patients and total 1513 scannings. The contents of its scan were plain CT (86.1%), CE (contrast enhancement) CT (7.3%) and both application methods (6.6%), and included from 1 CT time (85.3%), 2 CT times (9.6%), 3 CT times (3.3%),... til 7 CT times. Our CT scan cases were 720 males (58.6%) and 508 females (41.4%);its scan age level was mostly 40 y.o. -- over 70 y.o., but low age patients (under 10 y.o.) indicated number of 15.3%. In consideration of this fact the advantage of CT scan was very easily and safely procedure free from body lesion. 2) In number of CT scan: the most many patients were visiting department of internal medicine clinic, and following pediatric clinic, surgery and orthopedic department. Above all CT scan cases were included of other all clinical departments in our hospital. (CT scan was very useful for neurological examination). 3) In CT diagnosis our cases were it of cerebral infarction 128 (10.4%), cerebral hemorrage 19 (1.5%) and brain tumor 24 (2.3%), in small cases other craniocerebral diseases. 4) The visiting cases in internal medicine often complain of cerebrovascular symptomes, and in pediatric clinic chief complain was often suspected mental retardation and neurological sign. In surgery department it was suspected metastatic brain tumor from other malignant cancers, and in orthopedic surgery often skull injury or traffic accident. (J.P.N.)

  11. Study of brain metabolism using positron emission computed tomography

    International Nuclear Information System (INIS)

    Positron emission tomography permits the three-dimensional regional measurement of metabolism and blood flow in the brain. For the determination of cerebral metabolic rates of glucose by PET 18fluordeoxyglucose is usually applied: cerebral metabolic rate of glucose was found to be 36 to 47 μmol/100 g/min in the grey matter and 23 to 29 μmol/100 g/min in the white matter of normal volunteers. During physiologic activation metabolic rate of glucose is increased in the respective brain areas in relation to the strength and complexity of the stimulation. In patients suffering from ischaemic stroke glucose metabolism is markedly decreased within the infarction. Additonally, glucose metabolism is reduced by 20% in morphologically intact areas of the homolateral cortex, in the basal ganglia, in the cortical area contralateral to the infarction and in the contralateral cerebellum. This remote reduction of glucose utilization is probably caused by functional inactivation of these brain structures; it could be responsible for the diffuse organic syndrome in stroke victims not caused by the focal lesion. In patients suffering from dementia of the multi-infarct type and of the Alzheimer type glucose metabolism is reduced; the lesions in Alzheimer cases are most prominent in partietal and frontal cortical areas. In Chorea Huntington cases glucose metabolism is primarily disturbed in the striate, especially in the caudate nucleus; in these cases the metabolic disturbance can be detected earlier than the atrophy in computed tomograms. Disturbances of glucose and oxygen utilization are not necessary causes, but may also be sequelae od functional impairment. Additional information on pathogentic mechanisms may be obtained by the investigation of the protein synthesis. (orig.)

  12. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  13. Computed Tomography findings in Fournier's gangrene

    International Nuclear Information System (INIS)

    To assess the utility of computed tomography (CT) as an imaging technique in the diagnosis and determination of the extension of Fournier's gangrene (FG). We report the cases of six patients who had been clinically diagnosed as having FG, CT, enhanced by oral and intravenous contrast media, was performed in all the patients. All six patients presented soft tissue masses and gas in the scrotal region, which were also detected in the perineal region in five. In two patients, the gas extended toward anterior abdominal wall and in one of them, it also observed in anterior and posterior para renal space. The major predisposing factors were diabetes and alcoholism and the most common triggering factor was urologic disease. CT confirms the existence of FG and aids in assessing its extension and, in some cases, in identifying the underlying cause. (Author) 15 refs

  14. Computed tomography of primary intrahepatic biliary malignancy

    International Nuclear Information System (INIS)

    Fifteen patients with primary intrahepatic biliary malignancy (cholangiocarcinoma in 13, biliary cystadenocarcinoma in two) were examined by computed tomography (CT). The CT features were classified into three types: (A) a well-defined round cystic mass with internal papillary projections, (B) a localized intrahepatic biliary dilatation without a definite mass lesion, and (C) miscellaneous low-density masses. Intraphepatic biliary dilatation was noted in all cases of Types A and B and half of those of Type C; dilatation of extrahepatic bile ducts occurred in 4/4, 1/3, and 0/8, respectively. CT patterns, such as a well-defined round cystic mass with papillary projections or dilatation of intra- and extrahepatic ducts, give important clues leading to a correct diagnosis of primary intrahepatic biliary malignancy

  15. Radiation Protection in Paediatric Computed Tomography

    International Nuclear Information System (INIS)

    The number of examinations with radiation exposure has been increasing mainly due to advances in computed tomography (CT) technology, with a rapid expansion of CT utilization. Annually, 3.6 billion diagnostic and medical and dental examinations involving radiation are performed worldwide. The contribution of CT to collective dose due to medical X rays is up to 47–59%. A 2009 report of the National Council on Radiation Protection and Measurements (NCRP) estimates that 8–10% of CT examinations in the United States of America are performed on children; the growth in CT utilization is higher in the paediatric than adult population in the USA; and there is a particularly pronounced rise in adolescents undergoing chest CT in the emergency department setting for suspected pulmonary embolism or trauma. The reasons for the growing incidence of CT are new indications for CT with the advent of multidetector CT, overcautious ordering related to medico-legal problems and probably financial incentive systems

  16. Radiation Protection of Patients in Computed Tomography

    International Nuclear Information System (INIS)

    The use of radiation for medical diagnostic examinations contributes over 95% of human-made radiation exposure and is only exceeded by natural background as a source of exposure to the world’s population. In fact, for several developed countries, the increased use of high dose X ray technology, in particular, computed tomography (CT), has resulted in a situation in which the annual collective and per capita doses of ionizing radiation due to diagnostic radiology have exceeded those from natural background radiation. In light of this marked increase in worldwide collective effective dose from medical diagnostic procedures, and with CT scans accounting for half of this, there is great emphasis on the subject of radiation protection of patients in CT

  17. Quality assessment of clinical computed tomography

    Science.gov (United States)

    Berndt, Dorothea; Luckow, Marlen; Lambrecht, J. Thomas; Beckmann, Felix; Müller, Bert

    2008-08-01

    Three-dimensional images are vital for the diagnosis in dentistry and cranio-maxillofacial surgery. Artifacts caused by highly absorbing components such as metallic implants, however, limit the value of the tomograms. The dominant artifacts observed are blowout and streaks. Investigating the artifacts generated by metallic implants in a pig jaw, the data acquisition for the patients in dentistry should be optimized in a quantitative manner. A freshly explanted pig jaw including related soft-tissues served as a model system. Images were recorded varying the accelerating voltage and the beam current. The comparison with multi-slice and micro computed tomography (CT) helps to validate the approach with the dental CT system (3D-Accuitomo, Morita, Japan). The data are rigidly registered to comparatively quantify their quality. The micro CT data provide a reasonable standard for quantitative data assessment of clinical CT.

  18. Polychromatic phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Polychromatic phase-contrast radiography differs from traditional (absorption-only) radiography in that the method requires at least a partially coherent x-ray source and the resulting images contain information about the phase shifts of x-rays in addition to the traditional absorption information. In a typical embodiment, this effect results in a measurable enhancement in image contrast at the edges of objects. In this study, a phase-contrast imaging system was adapted to allow an object to be imaged at multiple projections, and these projections were used to generate phase-contrast computed tomography images. The images obtained with this technique show edge enhancements surrounding the objects within the image

  19. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  20. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  1. PRIMA+: a proton computed tomography apparatus

    International Nuclear Information System (INIS)

    The proton Computed Tomography (pCT) is a medical imaging method, based on the use of proton beams with kinetic energy of the order of 250 MeV, aimed to directly measure the stopping power distribution of tissues thus improving the present accuracy of treatment planning in hadron therapy. A pCT system should be capable to measure tissue electron density with an accuracy better than 1% and a spatial resolution better than 1 mm. The blurring effect due to multiple Coulomb scattering can be mitigated by single proton tracking technique. As a first step towards pCT the PRIMA+ Collaboration built a prototype capable to carry out a single radiography and a tomographic image of a rotating object. This apparatus includes a silicon microstrip tracker to identify the proton trajectory and a YAG:Ce calorimeter to measure the particle residual energy.

  2. Interpolation method in simple computed tomography scanner

    Science.gov (United States)

    Wiguna, Gede A.

    2015-03-01

    A method for sinogram data interpolation based on a sinusoidal pattern in computed tomography has been developed. Sampled sinograms were acquired based on angular interval scanning of 5o, 10o, and 20o. Then each resulted sinogram was interpolated following sinusoidal pattern to make a complete full scanning sinogram as if they were sampled at 1o. After that, a formal summation convolved filtered back projection was applied to each sinogram to yield a crosssectional image. This method was successfully interpolated limited number of projections data to obtained complete sinogram. It works for simple and homogenous object. However, for high variation of physical properties, e.g. linear attenuation coefficient values, this method needs more consideration on interpolation strategies to produce good image.

  3. Reporting of Dose in Computed Tomography

    International Nuclear Information System (INIS)

    Meaningful measurement and reporting of dose is an ongoing quest in computed tomography (CT). Expressions such as CTDIvol and dose length product are frequently used, but they describe machine output rather than dose to the patient. Further, they can be misleading when certain dose sparing technologies are employed. Size specific dose estimate has been proposed by the American Association of Physicists in Medicine as a more meaningful measure, but it approximates the mean dose to the patient centre rather than the dose to any specific organ. For estimates of patient risk, doses to specific organs are needed, but these are difficult to obtain. Medical physicists continue to try to resolve these issues, so that more meaningful estimates of dose from CT can be acquired. In the meantime, authors of scientific articles should be dissuaded from using meaningless expressions such as ‘low dose’ and ‘ultra-low dose’ in their descriptions of CT procedures. (author)

  4. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  5. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  6. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  7. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  8. Computed tomography findings in convergent strabismus fixus

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1995-08-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author).

  9. [Spontaneous intraparenchymatous hemorrhage: findings at computed tomography].

    Science.gov (United States)

    Soares, Celso Monteiro; Carvalho, Antonio Carlos Pires; Rodrigues, Andréa de Jesus

    2004-09-01

    Computed tomography studies of 250 patients with spontaneous hemorrhage were examined in three hospitals in the city of Rio de Janeiro. The goal of this study was to identify the aspects of this disease that appear most frequently in this type of exam. Deep intracerebral hematomas have had the highest incidence followed by lobar hemorrhage, with thalamus being more frequently affected. Cerebellar hemorrhage was much rarer, with brainstem bleeding observed in few patients. The age group with a peak incidence was at 61 to 70 years. Headache was the most frequently related symptom and elevated levels of blood pressure were found in most of the cases. There was no pronounced difference as to predominance in either sex or side most affected but it was observed that the onset of this disease occurs at an earlier age in men than in women. Blood draining into the ventricular system occurred more frequently in deep hematomas. PMID:15334231

  10. Myocardial hypoperfusion on conventional contrast computed tomography.

    Science.gov (United States)

    Ching, Shing; Chung, Tak Shun

    2015-10-01

    Non–electrocardiogram (ECG)–gated contrast computed tomography (CT) is commonly performed to exclude aortic dissection in chest pain patients. Besides evaluating the aorta for dissection flap, attention should be paid to the myocardium for areas of hypoenhancement that may suggest ischemia. Current models of multidetector CT enable assessment of myocardial perfusion with minimal motion artifact even without ECG gating. Transmural hypoenhancement with preserved wall thickness in a coronary distribution is highly specific for acute myocardial infarction. We report 2 cases of acute chest pain with initial nondiagnostic studies that underwent CT aortogram to exclude dissection. Instead, the CT showed myocardial hypoenhancement in left anterior descending artery territory. Myocardial hypoenhancement occurred before ST-segment elevation on ECG, suggesting that recognition of this important finding may lead to earlier revascularization decisions. PMID:26321167

  11. Perfusion computed tomography imaging of autoimmune pancreatitis

    International Nuclear Information System (INIS)

    Perfusion computed tomography (P-CT) is now available for the analysis of pancreatic blood flow. The aim of this study was to clarify pancreatic blood perfusion in AIP patients and the changes after steroid treatment. Color map imaging of P-CT and pancreatic time CT density curve (TDC) demonstrated that the pancreatic blood flow was attenuated in AIP patients. Pancreatic volumetric blood flow FV values of 11 AIP patients (82.7/min) were significantly lower than those of 12 normal controls (163.5/min, p=0.0006). AIP patients received steroid treatment and were re-examined, of these, 9 patients showed significantly elevated FV values after treatment (76.2/min and 109.8/min, p=0.0391, respectively). However, the changes of the values after the treatment differed in varying degrees among the individuals. P-CT is a useful method for the analysis of the blood flow in pancreatic diseases. (author)

  12. Computed tomography of the pituitary gland

    International Nuclear Information System (INIS)

    This book is written entirely to include the imaging of the pituitary gland by computed tomography (CT). The first three chapters illustrated technical aspects of scanning, anatomic depiction of the gland by CT, and the use of dynamic CT scanning for detecting and displaying abnormalities. The chapters discuss and illustrate various types of pathologic processes in and around the pituitary gland. One short but very helpful chapter demonstrates potential pitfalls due to the combination of anatomic variants and the geometry of CT sections. Some illustrations of disease processed are depicted by magnetic resonance imaging. All major types of pituitary diseases are illustrated. Lists of readily available English-language references are available. A small subject index is provided at the end of the book in which the illustrations are identified by use of a special numeric front

  13. Application of optical coherence tomography based microangiography for cerebral imaging

    Science.gov (United States)

    Baran, Utku; Wang, Ruikang K.

    2016-03-01

    Requirements of in vivo rodent brain imaging are hard to satisfy using traditional technologies such as magnetic resonance imaging and two-photon microscopy. Optical coherence tomography (OCT) is an emerging tool that can easily reach at high speeds and provide high resolution volumetric images with a relatively large field of view for rodent brain imaging. Here, we provide the overview of recent developments of functional OCT based imaging techniques for neuroscience applications on rodents. Moreover, a summary of OCT-based microangiography (OMAG) studies for stroke and traumatic brain injury cases on rodents are provided.

  14. Cerebral toxoplasmosis in AIDS - computerized tomography evaluation; Toxoplasmose cerebral na SIDA - avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Regina Coeli Fonseca [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Hospital Universitario Antonio Pedro. Servico de Radiologia; Narchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia

    1999-06-01

    Cerebral toxoplasmosis is a disease that affects many AIDS's patients. FOr this paper 46 patients with confirmed cases of cerebral toxoplasmosis who did a CT scan between March, 1994 and September, 1997 were examined. Single lesions were found in 28.3% of the patients. The lesions were more frequently detected in the basal ganglia and the frontal lobes. No lesion was larger than 4 cm. As regards the contrast enhancing of the lesions on a CT scan we observed that 54.5% of the lesions had a ring-like contrast enhancing, 36.4% had a nodular contrast enhancing and 6% had a heterogeneous form. After the 21st day of treatment we noticed an improvement in the aspect of the patients'lesions. The improvement of the lesions could be seen through a reduction of the edematous halo, a reduction of the lesion size and a modification in the contrast enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility with cerebral toxoplasmosis, as well as to monitor these patients during treatment. (author)

  15. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  16. 21 CFR 1020.33 - Computed tomography (CT) equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography (CT) equipment. 1020.33... Computed tomography (CT) equipment. (a) Applicability. (1) The provisions of this section, except for paragraphs (b), (c)(1), and (c)(2) are applicable as specified herein to CT x-ray systems manufactured...

  17. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J N; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  18. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  19. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  20. Cerebello-cerebral functional relationship in spinocerebellar degeneration using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koshi, Yasuhiko; Kitamura, Shin; Sakayori, Osamu; Komaba, Yuichi; Terashi, Akiro [Nippon Medical School, Tokyo (Japan)

    1995-07-01

    In order to investigate the laterality of cerebellar ataxia and its influence for the cerebral cortex in spinocerebellar degeneration (SCD), regional cerebral blood flow (rCBF) was measured using positron emission tomography (PET) in 10 patients with sporadic olivopontocerebellar atrophy (sOPCA), 7 patients with hereditary SCD (hSCD), and 10 age matched control subjects. The laterality of cerebellar ataxia was evaluated by the total score of the difference between left and right limbs of three limb-coordination tests. The lateralities of rCBF were calculated by asymmetry indices (AIs) of each region of interest in the cerebellum, thalamus, caudate, putamen, cerebral cortices. The laterality of cerebellar ataxia was significantly correlated with AI in the cerebellum in patients with sOPCA. Furthermore, significant negative correlations were observed between AI in the cerebellum and each AI in the thalamus, frontal cortex in patients with sOPCA. However, no correlations were observed between AI in the cerebellum and the other AIs in controls and patients with h SCD. Duration of illness in patients with sOPCA with laterality is shorter than that in patients without laterality. These results suggest that the existence of crossed cerebello-cerebral diaschisis (CCCD) resulting from transneuronal deactivation through cerebello-thalamo-cerebral pathway in patients with the early stage of sOPCA with laterality. (author).

  1. Determination of cerebral metabolic patterns in dementia using positron emission tomography

    International Nuclear Information System (INIS)

    With the introduction of the Kety-Schmidt method whole brain measurements of blood flow and metabolism were first applied to normal aged and demented patients. Chronically demented patients were consistently found to have marked reductions in cerebral blood flow, oxygen utilization, and glucose utilization when dementia was severe, and lesser reductions when it was mild. Others found that cerebral blood flow, oxygen utilization, and glucose utilization were decreased in parallel in late stages of Alzheimer's disease (AD) and multiple infarct dementia (MID). The intraarterial /sup 133/Xe method has been used to determine abnormalities in regional cerebral blood flow that correlate with cognitive deficits in patients with organic dementia, mostly Alzheimer's cases. Positron emission tomography (PET) and the /sup 18/F fluorodeoxyglycose (FDG) method have been applied to small numbers of demented patients with advanced AD. In general, decreases were found in global cerebral glucose utilization, but especially in temporal and parietal cortex. Others, using PET and the /sup 15/O/sub 2/ steady-state method, found a coupled decline in global cerebral blood flow and oxygen utilization that was correlated with increasing severity of dementia in both AD and MID, but there was no increase in oxygen extraction ratio, and therefore no evidence to support the existence of a chronic ischemic brain process. In this chapter, the author reviews some of the recent findings at UCLA using PET and the method in the study of normal aging and dementing disorders

  2. Computed tomography of neurodegenerative disease in childhood

    International Nuclear Information System (INIS)

    Serial computed tomographic scans were performed on seven children with neurodegenerative disorders. In two cases of white-matter diseases (Krabbe's disease and metachromatic leukodystrophy), diffuse, low-density lesions of white matter were visible in the early stage of the diseases. In one case of adrenoleukodystrophy, regional low-density lesions of the white matter around the posterior horns and peculiar high-density strip lesions were visible in the early stage. In two cases of storage-type gray-matter diseases (Tay-Sachs' and infantile Gaucher's disease), there were no abnormalities in the early stage, but diffuse cortical atrophies in the late stage. In one case of Leigh's disease, there were small, low-density lesions of the basal ganglia and multiple low-density lesions of the gray matter in the early stage. In one case of subacute sclerosing panencephalitis, there were no abnormalities in the early stage, but small, low-density lesions of the basal ganglia and diffuse cerebral atrophies in the late stage. Diagnostic values were recognized dominantly in two cases of adrenoleukodystrophy and Leigh's disease. In the other cases, however, serial CT scans were useful in the diagnostic process. (author)

  3. The role of computed tomography in the laryngeal injury

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hoon Sik [Capital Armed Forces General Hospital, Seongnam (Korea, Republic of)

    1984-03-15

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results.

  4. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  5. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  6. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  7. What does the psychiatrist expect of computed tomography

    International Nuclear Information System (INIS)

    In the author's opinion computed tomography should be applied as an instrument of basic research also in psychiatry. The problem of standardisation is, for the time being, not yet sufficiently solved. Wrong judgements on the cerebral cortex resulting from wrongly positive findings occur frequently. For re-handling the topic 'brain atrophy and psychosyndrome', which is important for clinical psychiatry, the CT-results should be compared with the findings obtained in the preceding systematical pneumoencephalographical-clinical correlation examinations. The excellent possibilities provided by the new method for practical diagnostics and research must be utilized with critical appreciation of the experience gained until now. If groups of examining of capacities closely co-operate over a long-term period, there may be some chances to bring some questions still open and unresolved closer to their solution and, maybe, even to finish the scientific handling of the complex of questions on 'brain atrophic and psychopathological finding' with radiological-morphological methods. (orig./MG)

  8. Single photon radionuclide computed tomography with Tomogscanner II, (1)

    International Nuclear Information System (INIS)

    The single photon radionuclide computed tomography (RCT) was examined in 214 patients with the Tomogscanner-II. The RCT of brain was superior to the conventional brain scan, especially in the detection of lesions at the base of brain or the postoperated condition. The blood pool RCT of brain depicted an arterio-venous malformation and a giant aneurysma at the base of brain. The RCT of cisternography was useful to understand the anatomical relationship of the activity. The RCT of cerebral blood perfusion was possible with a method of continuous infusion of sup(81m)Kr into an internal carotid artery. In the body study, the reconstructed image of the Tomogscanner was excellent. The area of myocardial infarction showed clear defect in the horse-shaped myocardial section image after injection of 4 mCi of 201TlCl. The RCT of liver was available to detect defects and evaluated the activity and size of spleen. The RCT of kidney, lung or bone also showed good image, respectively. The Tomogscanner-II gave very good images in clinical examination of body as well as brain. (author)

  9. Cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitario Cajuru

    International Nuclear Information System (INIS)

    Objective: to identify and analyze the prevalence of cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitario Cajuru. Materials and methods: cross-sectional study analyzing 200 consecutive non contrast-enhanced cranial computed tomography reports of patients admitted to the emergency unit of Hospital Universitario Cajuru. Results: alterations were observed in 76.5% of the patients. Among them, the following findings were most frequently observed: extracranial soft tissue swelling (22%), bone fracture (16.5%), subarachnoid hemorrhage (15%), nonspecific hypodensity (14.5%), paranasal sinuses opacification (11.5%), diffuse cerebral edema (10.5%), subdural hematoma (9.5%), cerebral contusion (8.5%), hydrocephalus (8%), retractable hypodensity /gliosis/ encephalomalacia (8%). Conclusion: the authors recognize that the most common findings in emergency departments reported in the literature are similar to the ones described in the present study. This information is important for professionals to recognize the main changes to be identified at cranial computed tomography, and for future planning and hospital screening aiming at achieving efficiency and improvement in services. (author)

  10. Computed tomography of normal distal tibiofibular syndesmosis

    International Nuclear Information System (INIS)

    The purpose of this study was to determine the shape and measurements of the normal distal tibiofibular syndesmosis on computed tomographic scans and to identify features that could aid in the diagnosis of syndesmotic diastasis using computed tomography (CT). CT scans of 100 patients with normal distal tibiofibular syndesmoses were reviewed retrospectively. In 67% the incisura fibularis was deep, giving the syndesmosis a crescent shape. In 33% the incisura fibularis was shallow, giving the syndesmosis a rectangular shape. The measurements of both types were taken using the same reference points. The mean age of the patients was 40 years, and there were 53 men and 47 women. The mean width of the distal tibiofibular syndesmosis anteriorly between the tip of the anterior tibial tubercle and the nearest point of the fibula was 2 mm. The mean width of the distal tibiofibular syndesmosis posteriorly between the medial border of the fibula and the nearest point of the lateral border of the posterior tibial tubercle was 4 mm. In men the mean width of the distal tibiofibular syndesmosis, anterior and posterior, was 2 mm and 5 mm, respectively, and in women it was 2 mm and 4 mm, respectively. This study provides measurements of the normal tibiofibular syndesmosis to aid in the diagnosis of occult diastasis. (orig.)

  11. Computed tomography of normal distal tibiofibular syndesmosis

    Energy Technology Data Exchange (ETDEWEB)

    Elgafy, Hossein; Semaan, Hassan B.; Blessinger, Brian; Wassef, Andrew; Ebraheim, Nabil A. [University of Toledo Medical Center, Departments of Orthopaedic Surgery and Radiology, Toledo, OH (United States)

    2010-06-15

    The purpose of this study was to determine the shape and measurements of the normal distal tibiofibular syndesmosis on computed tomographic scans and to identify features that could aid in the diagnosis of syndesmotic diastasis using computed tomography (CT). CT scans of 100 patients with normal distal tibiofibular syndesmoses were reviewed retrospectively. In 67% the incisura fibularis was deep, giving the syndesmosis a crescent shape. In 33% the incisura fibularis was shallow, giving the syndesmosis a rectangular shape. The measurements of both types were taken using the same reference points. The mean age of the patients was 40 years, and there were 53 men and 47 women. The mean width of the distal tibiofibular syndesmosis anteriorly between the tip of the anterior tibial tubercle and the nearest point of the fibula was 2 mm. The mean width of the distal tibiofibular syndesmosis posteriorly between the medial border of the fibula and the nearest point of the lateral border of the posterior tibial tubercle was 4 mm. In men the mean width of the distal tibiofibular syndesmosis, anterior and posterior, was 2 mm and 5 mm, respectively, and in women it was 2 mm and 4 mm, respectively. This study provides measurements of the normal tibiofibular syndesmosis to aid in the diagnosis of occult diastasis. (orig.)

  12. Texture classification of lung computed tomography images

    Science.gov (United States)

    Pheng, Hang See; Shamsuddin, Siti M.

    2013-03-01

    Current development of algorithms in computer-aided diagnosis (CAD) scheme is growing rapidly to assist the radiologist in medical image interpretation. Texture analysis of computed tomography (CT) scans is one of important preliminary stage in the computerized detection system and classification for lung cancer. Among different types of images features analysis, Haralick texture with variety of statistical measures has been used widely in image texture description. The extraction of texture feature values is essential to be used by a CAD especially in classification of the normal and abnormal tissue on the cross sectional CT images. This paper aims to compare experimental results using texture extraction and different machine leaning methods in the classification normal and abnormal tissues through lung CT images. The machine learning methods involve in this assessment are Artificial Immune Recognition System (AIRS), Naive Bayes, Decision Tree (J48) and Backpropagation Neural Network. AIRS is found to provide high accuracy (99.2%) and sensitivity (98.0%) in the assessment. For experiments and testing purpose, publicly available datasets in the Reference Image Database to Evaluate Therapy Response (RIDER) are used as study cases.

  13. Cerebral amobarbital sodium distribution during Wada testing: utility of digital subtraction angiography and single-photon emission tomography

    International Nuclear Information System (INIS)

    We aimed to determine if the cerebral distribution of anesthetic during Wada testing is reflected by findings on digital subtraction angiography (DSA) and single-photon emission computed tomography (SPECT) and if the findings on these studies are relevant to the outcome of the Wada test. We carried out selective internal carotid artery (ICA) DSA on 29 patients underwent studies prior to a Wada test. In patients without angiographic cross-filling, amobarbital and a radiotracer were injected into each ICA, beginning with the epileptogenic side. In patients with cross-filling, the ICA ipsilateral to the epileptogenic focus was injected with amobarbital and radiotracer while other was injected with amobarbital alone. We analyzed the DSA studies for cross-filling and filling of the posterior cerebral arteries (PCA). We reviewed the SPECT for activity in the territories of the anterior, middle cerebral, and posterior cerebral arteries. We compared the results of both studies with the success or failure of the neuropsychological portion of the Wada test. In 20 patients without cross-filling, the results of DSA and SPECT were comparable: symmetrical hemisphere activity was seen. In nine patients with cross-filling, SPECT showed bilateral, almost symmetrical activity. Filling or nonfilling of the PCA correlated with activity (or lack of it) in the medial temporal and occipital regions in all patients. The Wada test was considered successful in all patients. The findings on SPECT did not alter interpretation of the Wada test and we suggest that it may not be needed in all patients undergoing Wada testing. (orig.)

  14. Cerebral amobarbital sodium distribution during Wada testing: utility of digital subtraction angiography and single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Mukherji, S.K.; McCartney, W.H. [Department of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-11-01

    We aimed to determine if the cerebral distribution of anesthetic during Wada testing is reflected by findings on digital subtraction angiography (DSA) and single-photon emission computed tomography (SPECT) and if the findings on these studies are relevant to the outcome of the Wada test. We carried out selective internal carotid artery (ICA) DSA on 29 patients underwent studies prior to a Wada test. In patients without angiographic cross-filling, amobarbital and a radiotracer were injected into each ICA, beginning with the epileptogenic side. In patients with cross-filling, the ICA ipsilateral to the epileptogenic focus was injected with amobarbital and radiotracer while other was injected with amobarbital alone. We analyzed the DSA studies for cross-filling and filling of the posterior cerebral arteries (PCA). We reviewed the SPECT for activity in the territories of the anterior, middle cerebral, and posterior cerebral arteries. We compared the results of both studies with the success or failure of the neuropsychological portion of the Wada test. In 20 patients without cross-filling, the results of DSA and SPECT were comparable: symmetrical hemisphere activity was seen. In nine patients with cross-filling, SPECT showed bilateral, almost symmetrical activity. Filling or nonfilling of the PCA correlated with activity (or lack of it) in the medial temporal and occipital regions in all patients. The Wada test was considered successful in all patients. The findings on SPECT did not alter interpretation of the Wada test and we suggest that it may not be needed in all patients undergoing Wada testing. (orig.)

  15. Positron emission tomography alone, positron emission tomography-computed tomography and computed tomography in diagnosing recurrent cervical carcinoma: a systematic review and meta-analysis

    OpenAIRE

    Xiao, Yi; Wei, Jia; Zhang, Yicheng; Xiong, Weining

    2014-01-01

    Introduction The aim of the study was to assess systematically the accuracies of positron emission tomography (PET), PET/computed tomography (CT), and CT in diagnosing recurrent cervical cancer. Material and methods We searched for articles published from January 1980 to June 2013 using the following inclusion criteria: articles were reported in English; the use of PET, interpreted with or without the use of CT; use of CT to detect recurrent cervical cancer; and histopathologic analysis and/o...

  16. Regional brain hematocrit in stroke by single photon emission computed tomography imaging

    International Nuclear Information System (INIS)

    Nineteen studies on 18 subjects were performed by single photon emission computed tomography (SPECT) of the head after the successive intravenous administration of a plasma label (/sup 99m/Tc-human serum albumin [HSA]) and /sup 99m/Tc-labeled autologous red blood cells (RBC). Two sets of cerebral tomographic sections were generated: for cerebral /sup 99m/Tc-HSA alone and for combined /sup 99m/Tc-HSA and /sup 99m/Tc-RBC. By relating counts in regions of interest from the cerebral tomograms to counts from blood samples obtained during each tomographic acquisition, regional cerebral haematocrit (Hct) was calculated by the application of a simple formula. Results show 1) lower cerebral Hct than venous Hct (ratio of HCT brain/Hct venous 0.65-0.90) in all subjects, and 2) comparison between right and left hemisphere Hct in 3/3 normal subjects, 6/6 patients with transient ischaemic attacks and 3/8 patients with stroke showed no significant difference. However, in 3/8 patients with stroke (most recent strokes) significant differences were found, the higher Hct value corresponding to the affected side

  17. Giant hepatic cavernous hemangioma. Findings on computed helical tomography

    International Nuclear Information System (INIS)

    Objective: To describe computed helical tomography characteristics of the giant hepatic cavernous hemangioma. Method: During five years, we evaluated 21 patients with 21 giant hepatic cavernous hemangiomas with computed helical and multislice tomography. We included 18 women (86%) and 3 men (14%) with a mean age of 45 years. Results: The mean size of hemangiomas was 10.4 cm. Non enhanced computed tomography Showed 21 hemangiomas with lower density than adjacent hepatic parenchyma , all hemangiomas showed a central cleft area with low density. None hemangioma showed calcifications neither internal septa. In enhanced helical tomography all lesions demonstrated a globular, peripheral enhancing pattern with centripetal filling that begin in the arterial phase and continued in portal and delayed phases. None of the lesions showed complete filling. Conclusion: giant hepatic cavernous hemangiomas showed low attenuation in non enhanced computed tomography. central cleft area was very frequently seen. The enhancement pattern is characteristic, starting at the periphery with centripetal filling but it was never complete.

  18. Personal computer aided cerebral perfusion imaging with dynamic CT

    Institute of Scientific and Technical Information of China (English)

    林燕; 高培毅

    2004-01-01

    @@Reports on the clinical implementation of dynamic computerised tomography (CT) perfusion imaging and quantitative measurement have increased dramatically of late.1-8 The advantages of dynamic CT perfusion imaging and quantitative measurement for the diagnosis of acute cerebral infarction have been acknowledged. However, most overseas CT vendors set perfusion imaging software package as an option for graphic workstation at a too high price for domestic practitioners. To foster the domestic implementation and development of this new technology, we have extended the earlier work.1,2 Applying the theory of central volume principle to DICOM 3.0 standard forms of prime CT images, we developed dynamic CT perfusion imaging and quantitative measure-ment programmes for PCs using Visual C+ + in Windows 98 system.

  19. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Science.gov (United States)

    Miura, You; Seto, Akira; Kanazawa, Minoru; Nagata, Makoto

    2016-01-01

    Cerebral and cerebellar symptoms are frequently associated with Legionnaires' disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT) or magnetic resonance imaging (MRI). We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT) showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires' disease.

  20. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hiromitsu Ohta

    2016-01-01

    Full Text Available Cerebral and cerebellar symptoms are frequently associated with Legionnaires’ disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT or magnetic resonance imaging (MRI. We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires’ disease.

  1. Reproducibility in the assessment of acute pancreatitis with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: eofilho@ig.com.br; eoffilho@uol.com.br

    2007-11-15

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index ({kappa}). Results: Interobserver agreement was {kappa} 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was {kappa} = 0.796 and 0.732 for unenhanced morphological index; {kappa} 0.725 and 0.802 for contrast- enhanced morphological index; {kappa} = 0.674 and 0.849 for presence of pancreatic necrosis; {kappa} = 0.606 and 0.770 for pancreatic necrosis extension; and {kappa} = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  2. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  3. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  4. Radiation Doses from Computed tomography in Iraq

    International Nuclear Information System (INIS)

    Radiation doses to Patient during CT scanner and the radiological risk are significant. Patient dose survey has been conducted to investigate the Iraq patient radiation doses received in CT scanners in order to established reference dose levels. These doses are Entrance Surface Dose (ESD),computed tomography dose index(CTDI)), and dose length product (DLP). Two CT scanner were investigated in this study were, Siemens Somatom Plus 4, located in at medical city of Baghdad, and Philips, Optimus located in privet hospital at Baghdad. ESD were measured by TLD and Dosimax ionization chamber for head, chest, and abdomen for both sex and different weights. The TLD results were higher than that measured with Dosimax due to scattered radiation .The scattering factor which is the ratio between dose measured by TLD and that measured by ionization chamber range between (1.14-1.34) compare to international measurement which is range between (1.1-1.5).The (ESD) measured by the two methods were agree well after the subtraction of scattering dose, and have compered with original research. Dose profile were measured using array of TLD chips shows that its full width at half maximum is(7.99 mm) approximately equal the slice thickness(8 mm). Our results compare with reference level at U.K, European Guidelines and

  5. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  6. Quantitative investigations of megavoltage computed tomography

    Science.gov (United States)

    Rogers, Myron; Kerr, Andrew; Salomons, Greg; Schreiner, L. John

    2005-04-01

    Megavoltage computed tomography (MVCT) has been an active area of research and development in image guided radiation therapy. We have been investigating a particular implementation of MVCT in conjunction with studies of the potential for tomotherapy with a Cobalt-60 radiation source. In this paper, we present results comparing MVCT using a Co-60 source and a 4 MV linear accelerator to conventional kVCT imaging. The Co-60 and linac MVCT measurements were obtained with a first generation benchtop CT imager; the KVCT measurements were obtained using a Philips AcQSim CT Simulator). Phantoms containing various inserts ranging in density from air, through lung, soft tissue and bone equivalent materials and extending to high atomic number metals were imaged with the three modalities. The results enable characterization of image artifacts, CT number linearity and beam hardening. The MVCT images have sufficient contrast that soft tissue regions with 2.8% difference in electron density can be visualized. In MVCT, a linear relationship between CT numbers and electron densities extends to materials with Z ~ 60. In the 4MV CT imaging there is a position dependence of the CT numbers within a uniform water phantom, which is absent in Co-60 CT images, indicating the presence of beam hardening artifacts in the linac MVCT images. The differences between kVCT and MVCT will be discussed considering the variation of the photon interactions dominating the images. Our investigations indicate that MVCT has properties that may potentially extend its utility beyond radiation therapy.

  7. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  8. Computed tomography findings in fibrosing mediastinitis

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, A. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)]. E-mail: a.devaraj@rbht.nhs.uk; Griffin, N. [Department of Radiology, Chelsea and Westminster Hospital, London (United Kingdom); Nicholson, A.G. [Department of Histopathology, Royal Brompton Hospital, London (United Kingdom); Padley, S.P.G. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)

    2007-08-15

    Aim: To describe the CT features of fibrosing mediastinitis. Materials and methods: The clinical notes, histology, and CT images from 12 patients with fibrosing mediastinitis were reviewed. Clinical data regarding the presentation and suspected aetiology were correlated with location of mediastinal disease, calcification, effect on mediastinal structures, and additional pulmonary findings on computed tomography (CT). Results: The mean age was 40.5 years, with seven female and five male patients. The most common presenting symptom was shortness of breath. Fibrosing mediastinitis diffusely infiltrated the mediastinum in five patients and was localized in seven. Calcification was present in two cases. Eleven of 12 cases had narrowing of mediastinal structures, including five with pulmonary artery narrowing, five with superior vena cava obstruction, four with bronchial narrowing, three with tracheal narrowing, and one with narrowing of the pulmonary vein. The disease was considered idiopathic in seven cases with a demonstrable aetiology in five cases. Eight out of 12 patients had additional pulmonary findings, including all patients with a known aetiology. Conclusions: In the present series of patients, fibrosing mediastinitis more commonly presented as a localized mediastinal mass than as diffuse mediastinal disease, with the anterior mediastinal compartment most frequently involved. Most cases were idiopathic compared with the majority of previous cases at this institution being ascribed to tuberculosis. There is a high incidence of concomitant pulmonary findings, in particular when an identifiable aetiology is present. Obstruction of vital structures frequently gives rise to complications.

  9. Computed tomography findings in pancreas divisum

    International Nuclear Information System (INIS)

    In 29 patients with abdominal pain the diagnosis of pancreas divisum (PD) was verified by endoscopic retrograde pancreatography (EPR) via both the major and the minor papilla. Computed tomography (CT) was done in all patients to evaluate contour, volume, antero-posterior diameters and attenuation values of the gland in comparison with a normal reference series. Also, the validity of the CT grading of pancreatitis was assessed in comparison with ERP grading. Patients with PD had an increased cranio-caudal diameter of the pancreatic head (p<0.001). Further, the main pancreatic duct was visualized more often in patients with PD (p<0.01), who also had an increasing frequency of pancreatic calcifications (p<0.05). Otherwise there were no differences compared with the normal series. The observed reduction in the volume of the gland in patients with marked pancreatitis at ERP seemingly reflected the severity of inflammation. No cleavage between the dorsal and ventral anlage was identified. CT was found to be too unspecific to be of any use in grading of pancreatitis. In conclusion, CT findings in patients with PD are sparse, unspecific and preferably a reflection of pancreatitis, if present. ERP remains the ''gold standard'' for the diagnosis. (orig.)

  10. Computed tomography phantom for radiochromic film dosimetry

    International Nuclear Information System (INIS)

    To evaluate in detail the dose distribution during computed tomography (CT), a sheet roll CT dosimetry phantom (SRCT-P) with a radiochromic film (RF) was experimentally developed. The SRCT-P was made by rolling up a vinyl chloride sheet in a cylindrical shape to arbitrarily select the SRCT-P diameter, dose measurement position, and depth. The SRCT-P centre core consisted of a plastic hose in which a 10 mm acrylic bar with a RF was inserted. To determine the availability of the SRCT-P, the surface and centre doses (at a 5 mm radius) at each SRCT-P diameter (6-16 cm; every 2 cm) were measured. The ratios of the centre-to-surface doses (Dcentre/Dsuface) systematically increased, from 80 to 111%, for decreasing SRCT-P diameters, between 16 and 6 cm, respectively. The centre dose approached the surface dose as the SRCT-P diameter decreased. To use a RF for a CT dose measurement, further detailed research and analysis is necessary. However, this study has shown that a SRCT-P is useful and beneficial for the measurement of the dose distribution during a CT examination

  11. Computed tomography imaging and angiography - principles.

    Science.gov (United States)

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. PMID:27432657

  12. Industrial computed tomography image size measurement

    International Nuclear Information System (INIS)

    As one of the most useful modern detection technologies, Industrial Computed Tomography (ICT) image size measurement can correctly non-destructively measure the size of workpieces' inner construction, and it is considered as the standard for quality assurance and reverse engineering. In view of the advantages and disadvantages compared to conventional methods, this paper improves the precision of image size measurement with a new algorithm that uses an approximate function to describe edge degradation. First, this algorithm constructs the approximate function and determines the optimal point of edge detection, based on image intensity and inflexions. Then, in order to accurately extract the image edge, this algorithm is used to revise the primary image, completing construction of the CT image. Excellent results are obtained from simulations and experiments. The experimental results indicate that the relative error is 2% for the CT image when the step evolution of the image edge is pooled. The relative error of this method is decreased by as much as 1.5% compared to wavelet transformation and ridgelet transformation. Therefore, this new algorithm demonstrates increased effectiveness in extracting an accurate measurement of the CT image edge.

  13. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  14. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  15. Computed tomography of the ovarian tumors

    International Nuclear Information System (INIS)

    Computed tomography (CT) provides valuable informations in the diagnosis of the female pelvic masses. CT findings of 109 cases of surgically proved ovarian masses were reviewed regarding number, size, contour, and internal consistency (cystic, solid, and mixed masses). Differentiation between malignant and benign ovarian tumors depended on number and internal consistency of the mass. Most of malignant tumors showed bilateral mixed or solid masses and contained solid components. Most of metastatic ovarian cancer were demonstrated as bilateral mixed or solid masses. They were able to be differentiated from primary ovarian cancer because metastatic tumors contained more solid components than primary ones did and had ill-defined margins between cystic and solid components in mixed masses. In benign ovarian tumors, differentiation between mucinous cystadenomas, endometrial cysts, and dermoid cysts were possible. Mucinous cystadenomas showed the largest mulilocular cystic masses with band like septal thickening and their each locule demonstrated different densities. Endometrial cysts showed uni- or bilocular cystic masses with thick wall. Dermoid cysts were characterized by the presence of fatty component. It was concluded that CT is very useful in the tissue characterization of the ovarian masses by specific CT findings. (author)

  16. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  17. Dose profile in computed tomography chest scan

    International Nuclear Information System (INIS)

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58±5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  18. Computed tomography findings in middle ear anomaly

    International Nuclear Information System (INIS)

    The efficacy of computed tomography (CT) of the temporal bone was studied in 45 ears with a middle ear anomaly but whose tympanic membranes were normal. The plane of the film was 30 degrees oblique to the orbito-meatal line. Four otorhinolaryngologists made radiological diagnoses of the CT film without having any information about the patients. CT films of 40 normal ears were also evaluated and served as controls. The incudo-stapedial joint (I-S joint) and the stapes were visualized in all control group subjects. The percentage of correct diagnoses was 77.8% for separation of the I-S joint, and 75.6% for fixation of the stapes. The monopedal stapes was not visualized. Fixation of the malleus and the incus could not be diagnosed correctly. Abnormalities in the location of the facial nerve were visualized in a few ears. CT of the temporal bone was clinically useful for differentiating I-S joint separation and fixation of the stapes. (author)

  19. Computed tomography of the alveolar bone

    International Nuclear Information System (INIS)

    In addition to the conventional radiological methods used in odontology, computed tomography (CT) provides superposition-free images of the mandible and maxilla. Its value has been proved not only in cases of malignancy but also in many other problems. If an examination is performed with a slice thickness of less than 1.5 mm, the form and position of retained teeth in the alveolar bone, as well as subsequent lesions of neighboring permanent teeth, can be visualized so that early treatment can be planned. If the parodontal space of a retained tooth is visible, orthodontic intervention is possible. Precise assessment of horizontal or vertical bone loss is essential in inflammatory dental diseases. The morphology and extent of benign cystic lesions are also shown by CT. With CT surgical strategy of an intended implant therapy can take into account the remaining bone substance and the exact position of nerves and foramina. If such therapy is possible, the location, form and number of implants are easily defined. (orig.)

  20. Computed tomography and magnetic resonance colonography

    International Nuclear Information System (INIS)

    Colon cancer is the second leading cause of cancer death in the western world. Adenomatous colorectal polyps, which are found in 30-50% of Americans more than 50 years old, are recognized as important precursors of malignancy. Probably most of the invasive colon carcinomas arise from polyps. For this reason an early detection of these polyps and their complete removal is a recognized strategy for the prevention of colon cancer. So far no single method for an early diagnois of colon polyps or colon cancer offers high sensitivity and specificity along with low cost and good patient accccf Endo-opic colonoscopy allows the accurate detection of very small lesions and has since almost completely replaced fluooscopy. Cross-sectional imaging techniques, including magnetic resonance imaging (MRI) and computed tomography (CT), are increasingly being considered imaging modalities for the detection of colorectal polyps. CT and MR colonography are new techniques for imaging of the colon. In symptomatic patients, these new techniques show promising results for the detection of polyps equal to or larger than 1 cm in diameter. (author)

  1. Computed tomography experiments of Pantex high explosives

    Science.gov (United States)

    Perkins, D. E.; Martz, H. E.; Hester, L. O.; Sobczak, G.; Pratt, C. L.

    1992-04-01

    X-ray computed tomography is an advanced imaging technique which provide three-dimensional nondestructive characterization of materials, components and assemblies. The CT Project group at Lawrence Livermore National Laboratory (LLNL) and the Pantex Plant are cooperating to examine the use of CT technology to inspect and characterize high-explosives pressings (e.g., PBX-9502, LX-10-2). High-explosives pressings manufactured by Pantex must be characterized prior to assembling into weapons systems; a nondestructive examination of all assembly parts would be preferable to the current sampling and destructive testing. The earlier in the processing cycle this can be done the more cost effective it will be. We have performed experiments that show that this characterization can be performed at the pressed billet stage using CT. We have detected 2-mm inclusions in a 15-cm diameter billet and 3.5-mm voids in a 20-cm diameter billet. Based on these results we show calculations that can be used to design production CT systems for characterization of high-explosives.

  2. Computed Tomography Findings in Xanthogranulomatous Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Arumugam Rajesh

    2011-01-01

    Full Text Available Background: Xanthogranulomatous pyelonephritis (XGN is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. Purpose: To review the computed tomography (CT findings of patients diagnosed with XGN. Materials and Methods: A retrospective review of CT findings in patients with histologically proven XGN was carried out. Results: Thirteen CT examinations of 11 patients were analyzed. Renal enlargement was demonstrable on the affected side in all patients. Nine patients (82% had multiple dilated calyces and abnormal parenchyma. Six patients (55% had a renal pelvis or upper ureteric calculus causing obstruction. Three patients (27% had focal fat deposits identifiable within the inflamed renal parenchyma. Two patients had renal abscesses. Ten patients (91% had extrarenal extension of the inflammatory changes. Three patients (27% demonstrated extensive retroperitoneal inflammation. Conclusion: Unilateral renal enlargement and inflammation were the most consistent findings of XGN on CT. Perinephric inflammation and collections or abscess should also alert the radiologist to the possibility of this diagnosis.

  3. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  4. Relevance of computed tomography in gynecological tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, J.R.; Hagemann, J.

    1983-11-01

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography.

  5. Relevance of computed tomography in gynaecological tumors

    International Nuclear Information System (INIS)

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynaecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynaecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography. (orig.)

  6. Variations in measured computed tomography number values

    International Nuclear Information System (INIS)

    Computed Tomography (CT) scans of a water phantom have been performed on a number of different CT scanners, and variations in the measured mean pixel value for a central region have been observed. In addition, a positional variation of mean CT number was noted. In particular, the head rest on an EMI CT1010 scanner had a significant effect on the pixel values. To simulate head scanning, a phantom with a Teflon annulus surrounding a water bath was used. This annulus affected both the mean and standard deviation of the pixels in a central area of the scan. Both an mAS and beam width dependence on CT numbers was noted. The effect of calibration on the measured CT numbers for each reconstruction filter was examined on one machine. The variation of CT number with reconstruction matrix and compensation filter was also investigated. These measurements suggest caution must be exercised when interpreting actual CT number values. This will be particularly relevant when the numbers are used to differentiate between tissue types for diagnostic or therapeutic purposes. (author)

  7. Single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    The functional state of organs can be imaged by their accumulation of single photon emitter like 99mTc (γ-ray energy 140 keV), 201Tl (73 keV) and 201I (159 keV) with computed tomography. The emitted γ-ray is collimated to reach the NaI (Tl) detector for specifying its direction, which is called as the scintillation camera or gamma camera. The camera rotating around the patient gives the SPECT images. The NaI (Tl) detector is suitable for converting 60-300 keV γ-ray to fluorescence through the photoelectric effect. Photomultiplier receiving the fluorescence outputs X/Y signals for the emitting position and Z signal (energy) separately, giving imaging data. 3D images can be re-constructed by either method of the filtered back projection or maximum likelihood-expectation maximization. For quantitative reconstruction, correction of γ-ray absorption in water, of scattering and of collimator opening is necessary. Recently, semiconductor-detectors like CdZnTe and CdTe are being utilized in place of NaI for better resolution, which will reduce the size of the camera. Further, a camera with coincidence circuit for positron has appeared and will be applicable for both SPECT and PET. Compton camera having 2-step detectors without collimator is now under development. (N.I.)

  8. Perfusion computed tomography in renal cell carcinoma.

    Science.gov (United States)

    Das, Chandan J; Thingujam, Usha; Panda, Ananya; Sharma, Sanjay; Gupta, Arun Kumar

    2015-07-28

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma (RCC). While contrast enhanced computed tomography (CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT (pCT), goes down to the molecular level and provides new perspectives in imaging of RCC. pCT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using pCT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of pCT in staging and response assessment in patients with RCCs. PMID:26217456

  9. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  10. Dedicated breast computed tomography: Basic aspects

    International Nuclear Information System (INIS)

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed

  11. Patient doses for computed tomography in Hungary

    International Nuclear Information System (INIS)

    The latest initiative of the National Patient Dose Evaluation Program was an overall evaluation of patient doses for computed tomography. The aim of the survey was to collect data from which the patient doses of the CT examination of different body parts can be estimated and the most important technical parameters affecting on the patient exposures can be evaluated. The 54 CT scanners in clinical use in Hungary can be categorized into 31 different models from 8 manufacturers. Per caput frequency for CT is about 62.3 examinations per 1000 inhabitants. 59% of all examinations are connected to the head imaging. The highest mean effective dose arising from the chest and pelvis examinations, 6.98 mSv and 6.64 mSv, respectively. The yearly collective effective dose has been estimated at about 1700 manSv. This total dose is as much as the figure of 1785 manSv previously assessed for photofluorography applied in mass chest screening in Hungary. (author)

  12. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  13. Computed tomography guidance. Fluoroscopy and more

    International Nuclear Information System (INIS)

    Although ultrasound and magnetic resonance imaging are competitive imaging modalities for the guidance of needle-based interventions, computed tomography (CT) is the only modality suitable for image-guided interventions in all regions of the body, including the lungs and bone. The ongoing technical development of CT involves accelerated image acquisition, significantly improved spatial resolution, CT scanners with an extended gantry diameter, acceleration of the procedure through joystick control of relevant functions of interventional CT by the interventional radiologist and tube current modulation to protect the hands of the examiner and radiosensitive organs of the patient. CT fluoroscopy can be used as a real-time method (the intervention is monitored under continuous CT fluoroscopy) or as a quick check method (repeated acquisitions of individual CT fluoroscopic images after each change of needle or table position). For the two approaches, multislice CT fluoroscopy (MSCTF) technique with wide detectors is particularly useful because even in the case of needle deviation from the center slice the needle tip is simultaneously visualised in the neighboring slices. With the aid of this technique a precise placement of interventional devices is possible even in angled access routes and in the presence of pronounced respiratory organ movements. As the reduction of CT fluoroscopy time significantly reduces radiation exposure for the patient and staff, the combination of a quick check technique and a low milliampere technique with multislice CT fluoroscopy devices is advantageous. (orig.)

  14. Single photon emission computed tomography in Alzheimer's disease. Abnormal iofetamine I 123 uptake reflects dementia severity

    International Nuclear Information System (INIS)

    To determine whether abnormalities in regional cerebral functional activity estimated by iofetamine hydrochloride I 123 and single photon emission computed tomography can be detected in mild or moderate as well as severe cases of Alzheimer's disease (AD), we performed iofetamine I 123-single photon emission computed tomography in 37 patients with probable AD (nine patients with mild, 18 patients with moderate, and ten patients with severe dementia) and nine age-matched control subjects. Iofetamine I 123 uptake was measured in right and left frontal, temporal, parietal, and occipital cortices. Mean (right and left) iofetamine I 123 activity was lowest in the parietal region of patients with AD and was significantly reduced in the other three regions compared with control subjects. Only in the parietal region was lower relative iofetamine I 123 activity associated with an impaired level of patient function and with cognitive deficit

  15. Marked reduction of cerebral oxygen metabolism in patients with advanced cirrhosis; A positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Kawatoko, Toshiharu; Murai, Koichiro; Ibayashi, Setsurou; Tsuji, Hiroshi; Nomiyama, Kensuke; Sadoshima, Seizo; Eujishima, Masatoshi; Kuwabara, Yasuo; Ichiya, Yuichi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-01-01

    Regional cerebral blood flow (rCBF), cerebral metabolic rate of oxygen (rCMRO{sub 2}), and oxygen extraction fraction (rOEF) were measured using positron emission tomography (PET) in four patients with cirrhosis (two males and two females, aged 57 to 69 years) in comparison with those in five age matched controls with previous transient global amnesia. PET studies were carried out when the patients were fully alert and oriented after the episodes of encephalopathy. In the patients, rCBF tended to be lower, while rCMRO{sub 2} was significantly lowered in almost all hemisphere cortices, more markedly in the frontal cortex. Our results suggest that the brain oxygen metabolism is diffusely impaired in patients with advanced cirrhosis, and the frontal cortex seems to be more susceptible to the systemic metabolic derangements induced by chronic liver disease. (author).

  16. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  17. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    International Nuclear Information System (INIS)

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  18. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  19. Diagnosis of hoof disease in horses using computed tomography

    Directory of Open Access Journals (Sweden)

    Kovač Milomir

    2002-01-01

    Full Text Available This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Germany of 39 horses with hoof diseaseas. The most frequently findings were the navicular syndrome (eight horses, laminitis (seven horses, keratnoma (six horses and ossification of collateral cartilages in the distal phalanx (four horses. The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography.

  20. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  1. Diagnosis of sacral perineural cysts by computed tomography.

    Science.gov (United States)

    Tabas, J H; Deeb, Z L

    1986-07-01

    Three cases of sacral perineural cysts associated with chronic low-back pain are described with their myelography, computed tomography, and plain film findings. Significant findings include multiple cystic dilatations of lumbosacral nerve root sheaths, enlargement of the sacral foramina by masses isodense with cerebrospinal fluid, and asymmetric epidural fat distribution. Recognition of these findings on unenhanced computed tomography scans should preclude further evaluation by myelography and intrathecal metrizamide (Amipaque) computed tomography. These cysts are usually not the primary cause of back and leg pain. PMID:2942338

  2. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  3. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  4. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  5. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  6. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  7. Noninvasive xenon-133 measurements of cerebral blood flow using stationary detectors compared with dynamic emission tomography

    DEFF Research Database (Denmark)

    Schroeder, T; Vorstrup, S; Lassen, N A;

    1986-01-01

    asymmetry in the middle cerebral artery territory shown with the tomograph. As illustrated by a case history, the nontomographic CBF unit used in this study may provide reliable and useful information in patients with occlusive cerebrovascular disease by performing repeated CBF studies and challenging the...... the stationary detectors yielded somewhat lower CBF values than did emission tomography. Considering the side-to-side asymmetry, an excellent correlation was obtained. Using the initial slope index, the stationary detectors revealed quantitatively 83% of the interhemispheric asymmetry and 63% of the...

  8. Computerized tomography of five cases with global cerebral ischemic-anoxia

    International Nuclear Information System (INIS)

    Among eight cases with global cerebral ischemic-anoxia which were monitored with a serial computerized tomography (CT) scan, five had characteristic CT findings. It was revealed by the CT scan that, after diffuse brain swelling which had occurred immediately or a week after injury, remarkable brain atrophy appeared in two cases; these cases remained in the persistent vegetative state. In three other cases which were resuscitated one hour or more after injury, the CT scan showed symmetric low-density areas of the bilateral basal ganglia, and their prognoses were very poor: two died, while one remained in a near-brain-death state. (author)

  9. Caffeine and human cerebral blood flow: A positron emission tomography study

    International Nuclear Information System (INIS)

    Positron emission tomography (PET) was used to quantify the effect of caffeine on whole brain and regional cerebral blood flow (CBF) in humans. A mean dose of 250 mg of caffeine produced approximately a 30% decrease in whole brain CBF; regional differences in caffeine effect were not observed. Pre-caffeine CBF strongly influenced the magnitude of the caffeine-induced decrease. Caffeine decreased paCO2 and increased systolic blood pressure significantly; the change in paCO2 did not account for the change in CBF. Smaller increases in diastolic blood pressure, heart rate, plasma epinephrine and norepinephrine, and subjectively reported anxiety were also observed

  10. In vivo photoacoustic tomography of mouse cerebral edema induced by cold injury

    Science.gov (United States)

    Xu, Zhun; Zhu, Quing; Wang, Lihong V.

    2011-06-01

    For the first time, we have implemented photoacoustic tomography (PAT) to image the water content of an edema in vivo. We produced and imaged a cold-induced cerebral edema transcranially, then obtained blood vessel and water accumulation images at 610 and 975 nm, respectively. We tracked the changes at 12, 24, and 36 h after the cold injury. The blood volume decreased after the cold injury, and the maximum area of edema was observed 24 h after the cold injury. We validated PAT of the water content of the edema through magnetic Resonance Imaging and the water spectrum from the spectrophotometric measurement.

  11. Cerebrospinal fluid analysis detects cerebral amyloid-β accumulation earlier than positron emission tomography

    OpenAIRE

    Palmqvist, Sebastian; Mattsson, Niklas; Hansson, Oskar; ,

    2016-01-01

    See Rabinovici (doi:10.1093/brain/aww025) for a scientific commentary on this article. Cerebral accumulation of amyloid-β is thought to be the starting mechanism in Alzheimer’s disease. Amyloid-β can be detected by analysis of cerebrospinal fluid amyloid-β42 or amyloid positron emission tomography, but it is unknown if any of the methods can identify an abnormal amyloid accumulation prior to the other. Our aim was to determine whether cerebrospinal fluid amyloid-β42 change before amyloid PET ...

  12. In vivo deep brain imaging of rats using oral-cavity illuminated photoacoustic computed tomography

    Science.gov (United States)

    Lin, Li; Xia, Jun; Wong, Terence T. W.; Zhang, Ruiying; Wang, Lihong V.

    2015-03-01

    We demonstrate, by means of internal light delivery, photoacoustic imaging of the deep brain of rats in vivo. With fiber illumination via the oral cavity, we delivered light directly into the bottom of the brain, much more than can be delivered by external illumination. The study was performed using a photoacoustic computed tomography (PACT) system equipped with a 512-element full-ring transducer array, providing a full two-dimensional view aperture. Using internal illumination, the PACT system provided clear cross sectional photoacoustic images from the palate to the middle brain of live rats, revealing deep brain structures such as the hypothalamus, brain stem, and cerebral medulla.

  13. Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

    International Nuclear Information System (INIS)

    A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 μm was obtained at the spatial frequency of 4.3 μm-1 according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

  14. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  15. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  16. Computer tomography as a diagnostic technique in psychiatry

    International Nuclear Information System (INIS)

    CT findings in 516 hospitalized psychiatric patients are presented. The patients were classified in 9 groups according to a modified ICD classification, and type and incidence of pathological findings - almost exclusively degenerative processes of the brain - were registered. Diffuse cerebral atrophies are most frequent in the groups alcoholism and alcohol psychoses (44.0%) and psychoses and mental disturbances accompanying physical diseases. In schizophrenics, (almost exclusively residual and defect states) and in patients with affective psychosis diffuse cerebral atrophies are much less frequent (11.3% and 9.2%) than stated in earlier publications. Neurosis, changes in personality, or abnormal behaviour are hardly ever accompanied by cerebral atrophy. Problems encountered in the attempt to establish objective criteria for a diagnosis of cerebral atrophy on the basis of CT pictures are discussed. The computed tomograph does not permit conclusions on the etiology of diffuse atrophic processes. (orig.)

  17. Intracerebral hemorrhage auto recognition in computed tomography images

    International Nuclear Information System (INIS)

    The CT examination sometimes fail to localize the cerebral hemorrhage part depending on the seriousness and may embarrass the pathologist if he/she is not trained enough for emergencies. Therefore, an assisting role is necessary for examination, automatic and quick detection of the cerebral hemorrhage part, and supply of the quantitative information in emergencies. the computer based automatic detection and recognition system may be of a great service to the bleeding part detection. As a result of this research, we succeeded not only in automatic detection of the cerebral hemorrhage part by grafting threshold value handling, morphological operation, and roundness calculation onto the bleeding part but also in development of the PCA based classifier to screen any wrong choice in the detection candidate group. We think if we apply the new developed system to the cerebral hemorrhage patient in his critical condition, it will be very valuable data to the medical team for operation planning

  18. Dose modulated computed tomography automated dosimetry

    International Nuclear Information System (INIS)

    Full text: Computed Tomography (CT) scans contribute a significant portion of the effective radiation dose from medical procedures and generally large effective radiation doses per diagnostic examination. With the advent of Multislice CT, the potential for large radiation exposures increased. This combined with the appeal of the resultant isotropic imaging and the increasing number of applications for which CT could be utilised (including screening procedures) has further increased the need for vigilant monitoring of CT protocols and use with respect to radiation dose. The introduction of dose modulated Computed Tomography has proven an effective method for reducing patient dose and is now widely used by CT manufacturers. This involves lowering the mA when scanning through anatomical regions which do not require a large mA. Many CT investigations now utilise dose modulation. Some of these studies will include over 900 images for which the mA and occasionally other factors could vary. In order to utilise the existing software to perform CT dosimetry a program has been written to automatically extract scan parameters from CT dicom image files and apply the ImPACT CT Patient Dosimetry Calculator, for slices with differing factors. Matlab has been used to write and compile a program which sorts through a folder of dicom images and extracts the appropriate dicom header information. Some manufacturers store different series and reformatted images all within the same folder. The images of the CT study for which the dosimetry is to be performed must be stored within the one folder and must be in a dicom format. The program has been written to accommodate several manufacturers, which all contain different information in their dicom headers. The Matlab program groups the various study/image types, extracting the relevant dicom header information, which is written to an Excel worksheet. An Excel file uses this information to run the ImPACT CT Patient Dosimetry Calculator with

  19. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    International Nuclear Information System (INIS)

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions

  20. Radiological protection in paediatric computed tomography

    International Nuclear Information System (INIS)

    It is well known that paediatric patients are generally at greater risk for the development of cancer per unit of radiation dose compared with adults, due both to the longer life expectancy for any harmful effects of radiation to manifest, and the fact that developing organs and tissues are more sensitive to the effects of radiation. Multiple computed tomography (CT) examinations may cumulatively involve absorbed doses to organs and tissues that can sometimes approach or exceed the levels known from epidemiological studies to significantly increase the probability of cancer development. Radiation protection strategies include rigorous justification of CT examinations and the use of imaging techniques that are non-ionising, followed by optimisation of radiation dose exposure (according to the ‘as low as reasonably achievable’ principle). Special consideration should be given to the availability of dose reduction technology when acquiring CT scanners. Dose reduction should be optimised by adjustment of scan parameters (such as mAs, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Newer technologies such as tube current modulation, organ-based dose modulation, and iterative reconstruction should be used when appropriate. Attention should also be paid to optimising study quality (e.g. by image post-processing to facilitate radiological diagnoses and interpretation). Finally, improving awareness through education and advocacy, and further research in paediatric radiological protection are important to help reduce patient dose.

  1. Computed tomography of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    This article summarizes our preliminary results on high resolution computed tomography of 101 patients with various diffuse lung diseases. Instead of pattern recognition routinely done on chest radiogram (nodular, reticular or reticulo-nodular) we emphasized the relation of the lesions with inherent structures of the lung seen on the CT images. For this purpose our ten years radiologic-pathologic correlation on inflated and fixed lung specimens proved quite useful. 1) Centrilobular inflammatory nodules. This was seen in diffuse panbronchiolitis (DPB), allergic broncho-pulmonary aspergillosis, tuberculosis, pneumoconiosis and lobular pneumonia. DPB and bronchogenic spread of tuberculosis were most representative. The nodules produced by these diseases were located at the extreme end of bronchial branchings and separated by 2 to 3 mm from the pleura and pulmonary vein which constitute the edge of the secondary pulmonary lobule. 2) The lesions extending along bronchoarterial sheath and pulmonary vein. The contours of the pulmonary vessels were irregular and their calibers enlarged. These findings were seen in sarcoidosis and lymphangiosis carcinomatosa. 3) Lobular and multilobular lesions. This was seen in diffuse interstitial pneumonia and in alveolar filling diseases. The margins of the lesions were straight or curved slightly suggesting that disease is blocked by the lobular septa. Fine air bronchogram within the lesions was characteristic in chronic interstitial pneumonia. 4) Slight to moderate increase of lung density with multilobular distribution. This was seen in interstitial pneumonia, sarcoidosis and hypersensitivity pneumonitis. We supposed that this finding corresponds to cellular or fibrous thickening of alveolar septa, but direct proof was not available. (J.P.N.)

  2. Computed tomography in Duchenne type muscular dystrophy

    International Nuclear Information System (INIS)

    The computed tomography (CT) scan was performed on 91 Duchenne type muscular dystrophy (DMD) patients on the following four levels; (1) at the level of L3 vertebra, (2) 2-3cm above the symphysis pubica, (3) midposition of the thigh, (4) largest-diameter section of the lower leg. The CT of muscles common to most of the DMD patients were as follows: 1. Muscle atrophy: Muscle atrophy was shown as a reduction in the cross-sectional area of the muscles. Very mild muscle atrophy could be detected either by the clearly identified muscle border or by scattered low-density areas of so-called ''moth-eaten'' appearance within muscles. 2. Fat infiltration: The decrease in radio-density of muscles was interpreted as infiltration of fatty tissue. This type of density change was further classified into diffuse, streaked, cobblestone and salt-and-pepper patterns according to the spacial distribution of low-density areas. 3. Selectivity pattern: As the chronological sequence of DMD muscle degeneration is usually different among individual muscles, it may be seen, in some stages, that some of the synergistic muscles are still only slightly involved, while the others are quite severely atrophied with evident fat infiltration. In certain stages of the disease, most of the patients show relative preservation of particular muscles although they assumed a rounded shape. The most resistent muscle was musculus gracilis, followed by the musculus sartorius, musculus semitendinosus (and/or musculus semimembranosus) in that order. According to the severity of the CT changes, 86 of the 91 patients were classed into five stages from A1 to A5. Morphological stages (A1-A5) were well correlated to the functional disability stages by Ueda with a correlation factor of r=0.88. (J.P.N.)

  3. Dose in x-ray computed tomography.

    Science.gov (United States)

    Kalender, Willi A

    2014-02-01

    Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment. PMID:24434792

  4. The petromastoid canal on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A.; Schmitz-Rode, T.; Weidner, J.; Guenther, R.W. [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057 Aachen (Germany); Prescher, A. [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057 Aachen (Germany); DiMartino, E. [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057 Aachen (Germany)

    2002-11-01

    The objective was to assess visibility and anatomy of the petromastoid canal in high-resolution CT. Computed tomography images of 188 patients were reviewed for delineation of the petromastoid canal. This bony canal connects the mastoid antrum with the cranial cavity and houses the subarcuate artery and vein. The diameter, obtained in the middle portion of the canal, was compared with the diameter of the vestibular and cochlear aqueduct in all patients, and absolute values measured in 20 cases. Collimation was 1 mm in 164 and 2 mm in 24 examinations. Additionally, temporal bone of a cadaver was imaged and microdissected. The petromastoid canal was identified bilaterally in all 164 scans that were obtained with a slice thickness of 1 mm. In 5 of the 24 patients imaged with a collimation of 2 mm, the canal was not visible, most probably due to partial-volume effects. The petromastoid canal had the same diameter as the cochlear aqueduct in 42/44 (right/left), exceeded it in 66/61 and was smaller in 75/78 cases. In comparison to the vestibular aqueduct it had an equal diameter in 38/41 (right/left), exceeded it in 63/61, and was rated as smaller in 82/81 temporal bones. Diameters for the canals were: petromastoid canal 0.51{+-}0.04 mm; cochlear aqueduct 0.57{+-}0.03; and vestibular aqueduct 0.63{+-}0.06 mm. Microdissection of the specimen revealed the entire course of the canal and demonstrated a similar appearance of the structure as in the images. The petromastoid canal can easily be identified on high-resolution, thin-slice CT images. Knowledge of the anatomy of this bony canal prevents misinterpretation as pathological structure, such as fracture line, which might occur if this structure is not known. (orig.)

  5. Human cerebral acetylcholinesterase activity measured with positron emission tomography: procedure, normal values and effect of age

    International Nuclear Information System (INIS)

    The regional cerebral metabolic rate of [11C]N-methyl-4-piperidyl acetate, which is nearly proportional to regional cerebral acetylcholinesterase (AChE) activity, was measured by dynamic positron emission tomography in 20 healthy subjects with a wide age range (24-89 years). Quantitative measurement was achieved using a kinetic model which consisted of arterial plasma and cerebral tissue compartments. The plasma input function was obtained using thin-layer chromatography and an imaging phosphor plate system at frequent sampling intervals to catch the rapid metabolism of the tracer in the blood. The distribution of the rate constant k3, an index of AChE activity, agreed well with reported post-mortem AChE distribution in the cerebral cortex (0.067-0.097 min-1) and thalamus (0.268 min-1), where AChE activity was low to moderate. The k3 values in the striatum and cerebellum, where AChE activity was very high, did not respond linearly to AChE activity because of increased flow dependency. No significant effect of age was found on AChE activity of the cerebral cortex, suggesting that the ascending central cholinergic system is preserved in normal aging. This study has shown that quantitative measurement of enzyme activity in the living brain is possible through appropriate modelling of tracer kinetics and accurate measurement of the input function. The method should be applicable to patients with Alzheimer's disease and those with other kinds of dementia whose central cholinergic system has been reported to be disturbed. (orig.)

  6. Human cerebral acetylcholinesterase activity measured with positron emission tomography: procedure, normal values and effect of age

    Energy Technology Data Exchange (ETDEWEB)

    Namba, Hiroki [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Division of Neurological Surgery, Chiba Cancer Center, Chiba (Japan); Iyo, Masaomi [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Department of Psychiatry and Neurology, Hamamatsu University School of Medicine, Hamamatsu (Japan); Fukushi, Kiyoshi; Suhara, Tetsuya; Sudo, Yasuhiko; Suzuki, Kazutoshi; Irie, Toshiaki [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Shinotoh, Hitoshi [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Department of Neurology, Chiba University School of Medicine, Chiba (Japan); Nagatsuka, Shin-ichiro [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Tokai Research Laboratories, Daiichi Pure Chemical Co., Ltd., Ibaraki (Japan)

    1999-02-01

    The regional cerebral metabolic rate of [{sup 11}C]N-methyl-4-piperidyl acetate, which is nearly proportional to regional cerebral acetylcholinesterase (AChE) activity, was measured by dynamic positron emission tomography in 20 healthy subjects with a wide age range (24-89 years). Quantitative measurement was achieved using a kinetic model which consisted of arterial plasma and cerebral tissue compartments. The plasma input function was obtained using thin-layer chromatography and an imaging phosphor plate system at frequent sampling intervals to catch the rapid metabolism of the tracer in the blood. The distribution of the rate constant k{sub 3}, an index of AChE activity, agreed well with reported post-mortem AChE distribution in the cerebral cortex (0.067-0.097 min{sup -1}) and thalamus (0.268 min{sup -1}), where AChE activity was low to moderate. The k{sub 3} values in the striatum and cerebellum, where AChE activity was very high, did not respond linearly to AChE activity because of increased flow dependency. No significant effect of age was found on AChE activity of the cerebral cortex, suggesting that the ascending central cholinergic system is preserved in normal aging. This study has shown that quantitative measurement of enzyme activity in the living brain is possible through appropriate modelling of tracer kinetics and accurate measurement of the input function. The method should be applicable to patients with Alzheimer`s disease and those with other kinds of dementia whose central cholinergic system has been reported to be disturbed. (orig.) With 8 figs., 1 tab., 21 refs.

  7. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  8. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  9. The value of computed tomography in tuberous sclerosis

    International Nuclear Information System (INIS)

    The computed tomography (CT) findings in 5 patients with tuberous sclerosis are presented. CT is recommended as a rapid, non-invasive, easily repeated investigative procedure for patients with clinically suspected tuberous sclerosis and epilepsy of unknown origin

  10. Helical x-ray differential phase contrast computed tomography

    Science.gov (United States)

    Qi, Zhihua; Thériault-Lauzier, Pascal; Bevins, Nicholas; Zambelli, Joseph; Li, Ke; Chen, Guang-Hong

    2011-03-01

    Helical computed tomography revolutionized the field of x-ray computed tomography two decades ago. The simultaneous translation of an image object with a standard computed tomography acquisition allows for fast volumetric scan for long image objects. X-ray phase sensitive imaging methods have been studied over the past few decades to provide new contrast mechanisms for imaging an object. A Talbot-Lau grating interferometer based differential phase contrast imaging method has recently demonstrated its potential for implementation in clinical and industrial applications. In this work, the principles of helical computed tomography are extended to differential phase contrast imaging to produce volumetric reconstructions based on fan-beam data. The method demonstrates the potential for helical differential phase contrast CT to scan long objects with relatively small detector coverage in the axial direction.

  11. Use of computed tomography in nondestructive testing of polymeric materials

    International Nuclear Information System (INIS)

    Computed tomography has been used to detect imperfections and to measure cross-link density gradients in polymeric products, such as airplane tires, rubber shock absorbers, and filament-wound high-pressure tanks

  12. Measurement of regional cerebral blood flow with H215O positron emission tomography during Matas test - report of three cases

    International Nuclear Information System (INIS)

    The authors carried out a Matas test with a regional cerebral blood flow (rCBF) study using H215O positron emission tomography (PET) for three cases of large internal carotid artery aneurysms. There is a likely correlation between the cerebral blood flow (CBF) reduction rate obtained by PET, and the mean stump pressure available from a conventional balloon occlusion test. The advantages of this noninvasive and quantitative method are presented in comparison with other methods. (author)

  13. Clinical usefulness of positron emission tomography in the evaluation of regional cerebral blood flow and cerebral oxygen metabolism under glycerol and carbon dioxide loadings

    Energy Technology Data Exchange (ETDEWEB)

    Tanada, Shuji; Yonekura, Yoshiharu; Senda, Michio

    1987-02-01

    Cerebral blood flow (CBF) and oxygen metabolism (CMRO/sub 2/) were studied in normal cerebral cortices by positron emission tomography using continuous inhalation method of oxygen-15 labeled carbon dioxide and oxygen, and single inhalation method of oxygen-15 labeled carbon monoxide. The values of CBF, CMRO/sub 2/, and oxygen extraction fraction (OEF) in cerebral cortices of 18 healthy normal volunteers represented 40 +- 7 ml/100 ml/min, 3.2 +- 0.5 ml O/sub 2//100 ml/min, and 0.43 +- 0.07, respectively. In cases with glycerol loading, CBF increased in 10/14 cases. Studies of 6 cases with intracranial pressure indicated the presence of mechanism by which depressed CMRO/sub 2/ improved and was kept in normal values. The loading of 5% carbon dioxide showed an increase in CBF in cases with cerebral infarction, which implied the good cerebral vascular response to the elevated arterial carbon dioxide, but no particular changes were observed in CMRO/sub 2/ which seemed to be less responsive to the elevated arterial carbon dioxide level. In cases with moyamoya disease, 5% carbon dioxide loading showed no changes in CBF and CMRO/sub 2/. This suggested the poor cerebral vascular response to the elevation of arterial carbon dioxide, while X-ray CT failed to demonstrate any abnormalities in corresponding areas. Positron emission tomography proved to have a great potentiality regarding the evaluation of the changes in cerebral blood flow and cerebral oxygen metabolism under various loadings.

  14. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine

  15. Diagnosis of hoof disease in horses using computed tomography

    OpenAIRE

    Kovač Milomir; Nowak Michael; Kaufels Nikola; Tambur Zoran

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Germany) of 39 horses with hoof diseaseas. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnos...

  16. Dual energy computed tomography: Physical principles and methods

    OpenAIRE

    Κοντογιάννη, Λουκία

    2013-01-01

    The current thesis concerns Dual Energy Computed Tomography and specifically the physical principles and methods it is based on. Dual Energy CT offers the potential of not only anatomical, but also functional information from Computed Tomography (CT) exams. This is achieved by utilizing the energy dependence of X-rays’ attenuation within matter. In this way, materials are divided into those that are characterized by energy-dependent attenuation (strong spectral behavior), due t...

  17. Computed tomography of the mediastinum in myasthenia gravis

    International Nuclear Information System (INIS)

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours. (orig.)

  18. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  19. Value of positron emission tomography and computer tomography (PET/CT) for urologic malignancies

    International Nuclear Information System (INIS)

    Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning. (authors)

  20. [Value of positron emission tomography and computer tomography (PET/CT) for urologic malignancies].

    Science.gov (United States)

    Boujelbene, N; Prior, J O; Boubaker, A; Azria, D; Schaffer, M; Gez, E; Jichlinski, P; Meuwly, J-Y; Mirimanoff, R O; Ozsahin, M; Zouhair, A

    2011-07-01

    Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning. PMID:21507695

  1. Evaluation of intracerebral hematoma resorption dynamics with computed tomography

    International Nuclear Information System (INIS)

    High mortality and severe grade of disability observed in patients after intracerebral hemorrhage provide efforts to improve diagnostics and therapy of the hemorrhagic cerebral stroke. An aim of this paper was an evaluation of blood resorption dynamics in patients with intracerebral hematoma, performed with computed tomography of the head and an analysis of clinical significance of this process. An examined group included 133 patients with intracerebral hematoma proven by a CT exam. In 97 patients resorption of the hematoma was measured, based on control scans taken on 15th and 30th day on average. Volume of the hemorrhagic foci was measured as well as the width of ventricles and the displacement of medial structures. The mean hematoma volume reached 11,59 ml after 15 days, and 3,16 m after 30 days (average decrease of the volume 0,67 ml/day). There was a significant difference in the rate of resorption between the first (0-15 days) and the second (15-30 days) observation period - 0,78 and 0,62 ml/day respectively. The dynamics of the process was dependent on volume and localization of the hematoma and independent of the grade of displacement and compression of the ventricles. The calculated mean rate of the hematomas resorption enables to schedule control examinations precisely. The significant differences of the dynamics of blood resorption depending on hematomas size and the independence of compression and displacement of ventricular system suggest, that the most important factor in therapeutic decision-making should be a clinical status of the patient. (author)

  2. Study on cranial computed tomography in infants and children with central nervous system disorders, 2

    International Nuclear Information System (INIS)

    110 patients with cerebral palsy were studied by cranial computed tomography (CT) and electroencephalography (EEG) and the following results were obtained: 1) Abnormal brain findings on CT were present in 69% of spastic quadriplegia type, in 75% of spastic hemiplegia type, in 23% of athetotic type and in 50% of mixed type. 2) Most patients with spastic quadriplegia revealed diffuse cerebral atrophy and patients with spastic hemiplegia mostly showed hemispherial cerebral atrophy at the contralateral side to the motor paralysis on CT. Most patients with athetotis revealed normal CT-findings, but a few indicated slight diffuse cerebral atrophy on CT. 3) The severer was mental retardation of the patients, the more frequent and severer were CT-abnormalities. 4) Patients with epileptic seizure showed CT-abnormalities more often than patients without the seizure. 5) There was a good correlation between the abnormality of background activities on EEG and that on CT, in which their laterality coincided in most cases. 6) Sides of seizure discharges on EEG were the same as those of CT-abnormalities in 1/3 to 1/2 of patients, but the localization of seizure discharges corresponded to that of CT-abnormalities only in 11% of the cases. (author)

  3. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.

  4. Brain hypoperfusion on Tc-99m-ethylene dicysteine diethyl ester single-photon emission computed tomography in Hashimoto's encephalopathy

    International Nuclear Information System (INIS)

    We present a 17-year-old female, previously diagnosed of autoimmune hyperthyroidism who had an acute neurological episode and presented high antithyroid antibodies titers, cerebral spinal fluid and electroencephalogram changes. 99mTc ethylene dicysteine diethyl ester brain single-photon emission computed tomography (SPECT) showed global and patchy hypoperfusion. With glucocorticoid therapy, clinical symptoms disappeared; there was a decrease in antithyroid antibody levels and repeat brain SPECT revealed improvement of perfusion. (author)

  5. Regional Cerebral Glucose Metabolism in Novelty Seeking and Antisocial Personality: A Positron Emission Tomography Study

    Science.gov (United States)

    Park, So Hyeon; Park, Hyun Soo

    2016-01-01

    Novelty seeking (NS) and antisocial personality (ASP) are commonly exhibited by those who suffer from addictions, such as substance abuse. NS has been suggested to be a fundamental aspect of ASP. To investigate the neurobiological substrate of NS and ASP, we tested the relationship between regional cerebral glucose metabolism and the level of NS, determining the differences between individuals with and without ASP. Seventy-two healthy adults (43 males, mean age±SD=38.8±16.6 years, range=20~70 years; 29 females, 44.2±20.1 years, range=19~72 years) underwent resting-state brain positron emission tomography (PET) 40 minutes after 18F-fluorodeoxyglucose (FDG) injection. Within 10 days of the FDG PET study, participants completed Cloninger's 240-item Temperament and Character Inventory (TCI) to determine NS scores. Participants with and without ASP were grouped according to their TCI profiles. Statistical parametric mapping analysis was performed using the FDG PET and TCI profile data. NS scores positively correlated with metabolism in the left anterior cingulate gyrus and the insula on both sides of the brain and negatively correlated with metabolism in the right pallidum and putamen. Participants with ASP showed differences in cerebral glucose metabolism across various cortical and subcortical regions, mainly in the frontal and prefrontal areas. These data demonstrate altered regional cerebral glucose metabolism in individuals with NS and ASP and inform our understanding of the neurobiological substrates of problematic behaviors and personality disorders. PMID:27574485

  6. Challenges for computed tomography of overweight patients

    International Nuclear Information System (INIS)

    In morbidly obese patients, computed tomography frequently represents the only viable option for non-invasive imaging diagnostics. The aim of this study was to analyze the weight limits, dose and image quality with standard CT scanners and to determine the diagnostic value and dose with a dual source XXL mode. A total of 15 patients (average body weight 189.6±42 kg) were retrospectively identified who had been examined with the XXL mode. Of these patients 7 (average body weight 176.4±56 kg) had been examined using both the XXL and standard protocols allowing for an intraindividual comparison in this subcollective. Additionally 14 patients weighing between 90 and 150 kg (average 106.1±19 kg) examined with standard protocols were included as references. Dose, image noise and subjectively assessed image quality (rating scale 1-4) were determined. Additionally, a large abdomen phantom of 48 cm diameter was examined with both protocols at equivalent tube current-time product in order to compare the dose efficiency. The patient groups differed significantly in dose (CTDIvol XXL 72.9±23 versus standard 16.7±11 mGy; intraindividual 64.1±20 versus 27.0±15 mGy). The image noise was generally somewhat higher in the XXL group but significantly lower in the intraindividual comparison (liver 24.2±14 HU versus 36.3±20 HU; p=0.03; fat 15.5±8 HU versus 26.2±12 HU; p=0.02). With ratings of 1.9±0.7 and 1.8±0.7 image quality did not differ significantly in general, whereas there was a clear difference in the intraindividual comparison (1.8±0.8 versus 3.0±1.2) and only the XXL protocol achieved diagnostic quality in all cases, while 43% of the examinations with the standard protocol were rated as non-diagnostic. The quantification of dose efficiency in the phantom scans yielded no significant difference between the protocols. Up to 150 kg body weight, CT can be performed with the standard technique at 120 kVp with tube current modulation. In larger patients diagnostic

  7. Skeletal dosimetry in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Walters, B. R. B.; Ding, G. X.; Kramer, R.; Kawrakow, I. [Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada); Department of Radiation Oncology, Vanderbilt-Ingram Cancer Center, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-5671 (United States); Departamento de Energia Nuclear, Universidade Federal de Pernambuco, Avenida Professor Luiz Freire 1000, Cidade Universitaria, CEP 50740-540, Recife, Pernambuco (Brazil); Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada)

    2009-07-15

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm{sup 3}, with 17x17x17 {mu}m{sup 3} microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens ({approx}8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only {approx}50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  8. Skeletal dosimetry in cone beam computed tomography.

    Science.gov (United States)

    Walters, B R B; Ding, G X; Kramer, R; Kawrakow, I

    2009-07-01

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12 x 0.12 x 0.12 cm3, with 17 x 17 x 17 microm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/ MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (approximately 8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only approximately 50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment. PMID:19673190

  9. Skeletal dosimetry in cone beam computed tomography

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm3, with 17x17x17 μm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (∼8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only ∼50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  10. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  11. Computed tomography of the orbital tumors

    International Nuclear Information System (INIS)

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  12. Computed tomography of orbital diseases in childhood

    International Nuclear Information System (INIS)

    We analyzed computed tomography (CT) of 29 cases of various orbital diseases in pediatric age group. Diagnosis were confirmed by either operation or direct ophthalmoscope. The patients were examined during the period of last 3 years. The results were as follows: 1. Of 29 cases, 21 were male and 8 were female, and the age ranged from 20 days to 15 years. 2. Intraorbital tumors were 13 cases consisting of 7 retinoblastoma, 3 pseudotumor, and 1 each of congenital teratoma, cavernous lymphangioma, and optic glioma. Of remaining 16 cases, 6 had orbital fracture, 5 persistent hyperplastic primary vitreous (PHPV), 3 vitreous opacity, and 2 primary glaucoma. 3. The CT findings of the retinoblastoma were a lobulated or oval soft tissue mass density (40-60 HU) extending into the vitreous without significant enhancement on postcontrast scan. Of 7 cases, 4 had calcifications within the tumors. The extraglobal extension of the tumor was shown in 2 patients demonstrating markedly thickened sclera with enhancement and dilated optic nerve. 4. There were 5 patients with PHPV having a history of white pupil since birth, and all were affected unilateraly. Four patients had vitreous opacity and 3 of those showed either liner or branching tree-like densities within the vitreous on the postcontrast scan. Another one had a lobulated increased density protruding into the vitreous which was difficult to differenciate from the similar finding of retinoblastoma. Remaining one case demonstrated a deformed and decreased density in the lesional lens without change in the density of the vitreous. This was confirmed to be caused by persistence of the embryonic hyaloid artery attached to the posterior capsule of he lens. 5. There were 3 patients with vitreous opacity and 2 of them were due to retinal detachment and 1 was caused by retrolental fibroplasia. The CT findings of retinal detachment were homogeneous or heterogenous opacities in the vitreous. In a case of retrolental fibroplasia

  13. Brain computed tomography findings of aged schizophrenics

    International Nuclear Information System (INIS)

    Brain CT was performed in a total of 30 aged schizophrenic patients, consisting of 20 with no history of psychosurgery (lobotomy) and the other 10 lobotomized patients. The CT findings were compared with those from healthy aged persons. The group of schizophrenic patients had marked atrophy of the frontal lobe and dilatated Sylvian fissure as compared with the control group. There was no significant difference in ventricular factors between the two groups. These findings may have implications for the different mechanisms of the occurrence of atrophied brain surface and enlarged ventricle. The cerebral cortex involved in the occurrence of schizophrenia may be affected by aging-related cerebral atrophy, in addition to the morphological changes due to schizophrenia. Thus, schizophrenic cerebral atrophy was more noticeable than physiological aging-related atrophy. However, enlargement of the ventricle in the schizophrenic group progressed with aging in the same manner as that in the normal group. In comparing schizophrenic patients with or without a history of lobotomy, atrophy of the brain surface and enlargement of the ventricle were more marked in the lobotomized patients than the non-lobotomized patients. This confirmed that lobotomy, as well as surgical scar, is involved in the morphology of schizophrenic brain. (N.K.)

  14. Computed tomography perfusion imaging in acute stroke

    International Nuclear Information System (INIS)

    The development of thrombolytic and neuroprotective agents for the treatment of acute stroke has created an imperative for improved imaging techniques in the assessment of acute stroke. Five cases are presented to illustrate the value of perfusion CT in the evaluation of suspected acute stroke. To obtain the perfusion data, a rapid series of images was acquired without table movement following a bolus of contrast medium. Cerebral blood flow, cerebral blood volume and mean transit time were determined by mathematically modelling the temporal changes in contrast enhancement in the brain and vascular system. Pixel-by-pixel analysis allowed generation of perfusion maps. In two cases, CT-perfusion imaging usefully excluded acute stroke, including one patient in whom a low-density area on conventional CT was subsequently proven to be tumour Cerebral ischaemia was confirmed in three cases, one with an old and a new infarction, one with a large conventional CT abnormality but only a small perfusion defect, and one demonstrating infarct and penumbra. Perfusion CT offers the ability to positively identify patients with non-haemorrhagic stroke in the presence of a normal conventional CT, to select those cases where thrombolysis is appropriate, and to provide an indication for prognosis. Copyright (2002) Blackwell Science Pty Ltd

  15. Preoperative diagnosis of gastric cancer using plain computed tomography and dynamic computed tomography

    International Nuclear Information System (INIS)

    The accuracy of preoperative diagnosis using computed tomography with or without contrast enhancement in detecting the depth of tumor invasion in the gastric wall and the presence or absence of lymph node metastasis was compared based on histological findings in 94 gastric cancer patients who underwent gastrectomy. The diagnostic accuracy rate of plain CT for gastric wall invasion was less than dynamic CT. Particularly in the evaluation of invasion to another organ, the diagnostic accuracy of dynamic CT was higher (84%) than plain CT (56%). The diagnostic accuracy and sensitivity of dynamic CT for lymph node metastasis was significantly higher than that of plain CT. With respect to the detection of metastasis to group 2 lymph nodes (especially No. 7, 8, 9, and 11), the sensitivity of dynamic CT was higher than that of plain CT. We conclude that dynamic CT is an available preoperative diagnostic procedure for detecting lymph node metastasis and serosal invasion. (author)

  16. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Science.gov (United States)

    Wong, Ka-Kit; Gandhi, Arpit; Viglianti, Benjamin L; Fig, Lorraine M; Rubello, Domenico; Gross, Milton D

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography (SPECT)/computed tomography (CT) hybrid imaging for diagnosis of various endocrine disorders. METHODS: We performed MEDLINE and PubMed searches using the terms: “SPECT/CT”; “functional anatomic mapping”; “transmission emission tomography”; “parathyroid adenoma”; “thyroid cancer”; “neuroendocrine tumor”; “adrenal”; “pheochromocytoma”; “paraganglioma”; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts (case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology. RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the bio-distribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTc- labeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol (NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma. CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy

  17. Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Faccioli, Niccolo; Foti, Giovanni; Barillari, Marco; Mucelli, Roberto Pozzi [University of Verona, Department of Radiology, G.B. Rossi Hospital, Verona (Italy); Atzei, Andrea [University of Verona, Department of Hand Surgery, G.B. Rossi Hospital, Verona (Italy)

    2010-11-15

    To compare the diagnostic accuracy and radiation exposure of cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) in the evaluation of finger fractures. In a 3-year period, 57 consecutive patients with post-traumatic fractures of the metacarpal-phalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints with involvement of the articular surface were studied by means of CBCT and MSCT. Student's t test was used to compare CBCT and MSCT accuracy in evaluating the percentage of joint surface involvement and in detecting bone fragments. The average tissue-absorbed doses of CBCT and MSCT were also compared. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated. In all cases, CBCT allowed the percentage of articular involvement to be correctly depicted compared with MSCT, showing 100% sensitivity and specificity (p < 0.001). A total of 103 bone fragments were depicted on MSCT (mean 3.8 per patient, range 1-23). CBCT indicated 92 out of 103 fragments (89.3%) compared with MSCT (mean diameter of missed fragments 0.9 mm, range 0.6-1.3 mm), with no statistically significant difference between CBCT and MSCT (p < 0.025). Multislice CT radiation exposure was significantly higher than that of CBCT (0.18 mSv vs 0.06 mSv, p < 0.0025). Inter-observer agreement was good (overall {kappa} = 0.89-0.96). Cone beam CT may be considered a valuable imaging tool in the preoperative assessment of finger fractures, when MSCT is not available. (orig.)

  18. Ruptured intracranial aneurysm during pregnancy with false-negative computed tomography angiography findings: a case report.

    Science.gov (United States)

    Goto, Yukihiro; Ebisu, Toshihiko; Mineura, Katsuyoshi

    2015-06-01

    A 34-year-old female was admitted at 34 weeks of gestation with sudden onset of a severe headache accompanied by vomiting. Neurological examination revealed neck rigidity, and computed tomography (CT) of the brain revealed a subarachnoid hemorrhage (SAH). Although the hemorrhage was located primarily in the left Sylvian fissure, computed tomography angiography (CTA) performed immediately after CT did not reveal any obvious vascular abnormalities such as an intracranial aneurysm. An emergency cesarean section was performed, and a healthy infant was delivered. Cerebral digital subtraction angiography (DSA) was performed the day following surgery, which revealed a saccular aneurysm measuring 4.3 mm × 2.4 mm in the left middle cerebral artery. Left craniotomy and clipping of the aneurysm were performed. The clot around the aneurysm was relatively solid. This case report is of significance given that initial CTA was negative for SAH during pregnancy, suggesting the requirement for immediate DSA or another CTA in such cases. There are many previous reports on false-negative CTA findings or disappearance and reappearance of aneurysms in SAH patients, and various biophysical and dynamic parameters are suggested to cause such phenomena. However, there are no reports on similar occurrences during pregnancy. Although the precise cause remains unclear, multiple factors associated with homeostasis during pregnancy were possibly associated with the transient disappearance in this patient. PMID:25732356

  19. Computed tomography in penetrating injury to the eye.

    Science.gov (United States)

    Bhimani, S; Virapongse, C; Sarwar, M; Twist, J F

    1984-05-01

    We used computed tomography to detect and localize foreign bodies in two unusual cases of penetrating injury to the eyes. In one case, a large broken twig appeared to have penetrated the globe and the inferior rectus muscle; in the other, the globe was ruptured by many glass shards . In the first case surgery showed the computed tomographic impression to be incorrect. The globe and the inferior rectus muscle were intact and vision and motility were normal postoperatively. In the second case, swelling made direct visualization impossible, and computed tomography was used to locate the foreign bodies. PMID:6720836

  20. Development of a proton Computed Tomography detector system

    International Nuclear Information System (INIS)

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector