WorldWideScience

Sample records for cerebral computed tomography

  1. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  2. Computed tomography in spastic cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, H.; Taudorf, K.; Melchior, J.C.

    1982-09-01

    Eighty-three children with spastic cerebral palsy (CP) were examined with cranial CT. In 56 cases the CT findings were abnormal. The most frequent abnormality was atrophy, present in 44 patients. The frequency of pathologic CT increased with severity of the CP. Patients with CP of postnatal aetiology more often had abnormal CT than patients with other known causes. Pathologic CT findings were seen more often in patients with seizures than in patients without. Infarctions and hemiatrophy were much more frequent in patients with hemiplegia than in patients with other types of spastic CP. A special kind of central atrophy, called isolated atrophy around the cella media, is described. This condition was seen in 20% of cases, most often in hemi- and paraplegic patients. Early infarctions in the border areas between the vascular territories of the internal carotid and the posterior cerebral artery may be the reason for this kind of atrophy.

  3. Comparison of Cerebral Oxygen Saturation and Cerebral Perfusion Computed Tomography in Cerebral Blood Flow in Patients with Brain Injury.

    Science.gov (United States)

    Trofimov, Alexey O; Kalentiev, George; Voennov, Oleg; Grigoryeva, Vera

    2016-01-01

    The purpose of this study was to determine the relationship between cerebral tissue oxygen saturation and cerebral blood volume in patients with traumatic brain injury. Perfusion computed tomography of the brain was performed in 25 patients with traumatic brain injury together with simultaneous SctO2 level measurement using cerebral near-infrared oxymetry. The mean age of the injured persons was 34.5±15.6 years (range 15-65); 14 men, 11 women. The Injury Severity Score (ISS) values were 44.4±9.7 (range 25-81). The Glasgow Coma Score (GCS) mean value before the study was 10.6±2.1 (range 5-13). SctO2 ranged from 51 to 89%, mean 62±8.2%. Cerebral blood volume (CBV) values were 2.1±0.67 ml/100 g (min 1.1; max 4.3 ml/100 g). Cerebral blood flow (CBF) was 31.99±13.6 ml/100 g×min. Mean transit time (MTT) values were 5.7±4.5 s (min 2.8; max 34.3 s). The time to peak (TTP) was 22.2±3.1 s. A statistically significant correlation was found between SctO2 level and cerebral blood volume (CBV) level (R=0.9; pperfusion.

  4. Cerebral computed tomography in men with acquired immunodeficiency syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brun, B.; Boesen, F.; Gerstoft, J.; Nielsen, J.O.; Praestholm, J.

    Cerebral CT scannings were performed in 19 homosexual men with the acquired immunodeficiency syndrome (AIDS). Nearly half of them (9 patients) had cortical atrophy. Three patients with toxoplasmosis had cerebral pathology, in two of them with ring enhancement while the third had an ill-defined nonspecific lesion with slight heterogeneous enhancement without ring formation. Two patients with multifocal leucoencephalopathy and non-Hodgkin's lymphoma, respectively, presented non-enhancing, low attenuating lesions at CT.

  5. A study of cerebral perfusion using single photon emission computed tomography in neonates with brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, J.; Contantinesco, A.; Brunot, B.; Messer, J. (Hospital Universitaire de Strasbourg (France))

    1994-03-01

    In this study the authors used a single photon emission computed tomography technique (SPECT) with radiolabelled [sup 99m]Tc HMPAO to assess cerebral perfusion in newborn infants with documented cerebral lesions and to determine to what extent brain SPECT might be useful in the neonatal period. A total of 15 newborn infants with the following cerebral pathologies were enrolled: severe parietal bilateral periventricular leucomalacia; moderate parietal bilateral PVL; intraventricular haemorrhage grade II with unilateral parietal parenchymal extension; cerebral infarction in the zone of middle cerebral artery; and post-haemorrhagic hydrocephalus. Follow-up was available in all infants. Alterations in cerebral perfusion were seen in only 12 of 15 infants and at the location of severe PVL, PE and CI. It was noted that the regions of diminished perfusion extended beyond the apparent extent of cerebral pathology delineated by ultrasound or magnetic resonance imaging. Markedly diminished perfusion was seen in one infant with hydrocephalus, which recovered following placement of ventriculo-peritoneal shunt. Regarding outcome, SPECT data failed to provide additional information than that of neuroradiological investigations. It is concluded that the use of SPECT, under these conditions, to assess alteration of cerebral perfusion in the neonatal period will not provide any additional information than that of neuroradiological investigations. 17 refs., 3 figs., 1 tab.

  6. Incidental Diagnosis of Cerebral Cortical Venous Thrombosis in Postdural Puncture Headache on Brain Computed Tomography.

    Science.gov (United States)

    Humbertjean, Lisa; Ducrocq, Xavier; Lacour, Jean-Christophe; Mione, Gioia; Richard, Sébastien

    2015-01-01

    Diagnosis of cerebral cortical venous thrombosis in patients with postdural puncture headache (PDPH) is usually secondary to changes in headache pattern or cerebral infarctions. Nevertheless, incidental discovery of asymptomatic forms on brain imaging has never been reported before and its management thus remains ill-defined. We describe 2 cases of patients with asymptomatic cortical vein thrombosis in the context of PDPH. In both cases, brain computed tomography (CT) scans showed an isolated cortical vein thrombosis without cerebral damage. Neurological examination revealed the typical orthostatic feature of PDPH, independently of cortical vein thrombosis which was considered as a radiological incidental finding. Clinical and radiological signs resolved after bed rest, oral caffeine, and anticoagulation therapy. Asymptomatic cortical vein thrombosis may be found on radiological exploration, even basic like brain CT scan without contrast, of PDPH. Utility of anticoagulation therapy, which could increase the risk of cerebral hemorrhagic complications in this specific context, has to be assessed.

  7. Assessing regional cerebral blood flow in depression using 320-slice computed tomography.

    Directory of Open Access Journals (Sweden)

    Yiming Wang

    Full Text Available While there is evidence that the development and course of major depressive disorder (MDD symptomatology is associated with vascular disease, and that there are changes in energy utilization in the disorder, the extent to which cerebral blood flow is changed in this condition is not clear. This study utilized a novel imaging technique previously used in coronary and stroke patients, 320-slice Computed-Tomography (CT, to assess regional cerebral blood flow (rCBF in those with MDD and examine the pattern of regional cerebral perfusion. Thirty nine participants with depressive symptoms (Hamilton Depression Rating Scale 24 (HAMD24 score > 20, and Self-Rating Depression Scale (SDS score > 53 and 41 healthy volunteers were studied. For all subjects, 3 ml of venous blood was collected to assess hematological parameters. Transcranial Doppler (TCD ultrasound was utilized to measure parameters of cerebral artery rCBFV and analyse the Pulsatility Index (PI. 16 subjects (8 =  MDD; 8 =  healthy also had rCBF measured in different cerebral artery regions using 320-slice CT. Differences among groups were analyzed using ANOVA and Pearson's tests were employed in our statistical analyses. Compared with the control group, whole blood viscosity (including high\\middle\\low shear rateand hematocrit (HCT were significantly increased in the MDD group. PI values in different cerebral artery regions and parameters of rCBFV in the cerebral arteries were decreased in depressive participants, and there was a positive relationship between rCBFV and the corresponding vascular rCBF in both gray and white matter. rCBF of the left gray matter was lower than that of the right in MDD. Major depression is characterized by a wide range of CBF impairments and prominent changes in gray matter blood flow. 320-slice CT appears to be a valid and promising tool for measuring rCBF, and could thus be employed in psychiatric settings for biomarker and treatment response purposes.

  8. Racking the brain: Detection of cerebral edema on postmortem computed tomography compared with forensic autopsy

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Nicole [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Ampanozi, Garyfalia; Schweitzer, Wolf; Ross, Steffen G.; Gascho, Dominic [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Ruder, Thomas D. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic, Interventional and Pediatric Radiology, University Hospital of Bern, Freiburgstrasse, 3010 Bern (Switzerland); Thali, Michael J. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.uzh.ch [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2015-04-15

    Graphical abstract: -- Highlights: •Postmortem swelling of the brain is a typical finding on PMCT and occurs concomitant with potential antemortem or agonal brain edema. •Cerebral edema despite normal postmortem swelling is indicated by narrowed temporal horns and symmetrical herniation of the cerebral tonsils on PMCT. •Cases with intoxication or asphyxia demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units) and a ratio >1.58 between the gray and white matter. •The Hounsfield measurements of the white and gray matter help to determine the cause of death in cases of intoxication or asphyxia. -- Abstract: Purpose: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. Materials and methods: The study collective included a total of 109 cases (n = 109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. Results: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p < 0.001). There was a significant difference (p < 0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to

  9. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome.

    Directory of Open Access Journals (Sweden)

    Chien Hung Chang

    Full Text Available BACKGROUND: Hyperperfusion syndrome (HPS following carotid angioplasty with stenting (CAS is associated with significant morbidity and mortality. At present, there are no reliable parameters to predict HPS. The aim of this study was to clarify whether perfusion computed tomography (CT is a feasible and reliable tool in predicting HPS after CAS. METHODOLOGY/PRINCIPAL FINDINGS: We performed a retrospective case-control study of 54 patients (11 HPS patients and 43 non-HPS with unilateral severe stenosis of the carotid artery who underwent CAS. We compared the prevalence of vascular risk factors and perfusion CT parameters including regional cerebral blood volume (rCBV, regional cerebral blood flow (rCBF, and time to peak (TTP within seven days prior to CAS. Demographic information, risk factors for atherosclerosis, and perfusion CT parameters were evaluated by multivariable logistic regression analysis. The rCBV index was calculated as [(ipsilateral rCBV - contralateral rCBV/contralateral rCBV], and indices of rCBF and TTP were similarly calculated. We found that eleven patients had HPS, including five with intracranial hemorrhages (ICHs of whom three died. After a comparison with non-HPS control subjects, independent predictors of HPS included the severity of ipsilateral carotid artery stenosis, 3-hour mean systolic blood pressure (3 h SBP after CAS, pre-stenting rCBV index >0.15 and TTP index >0.22. CONCLUSIONS/SIGNIFICANCE: The combination of severe ipsilateral carotid stenosis, 3 h SBP after CAS, rCBV index and TTP index provides a potential screening tool for predicting HPS in patients with unilateral carotid stenosis receiving CAS. In addition, adequate management of post-stenting blood pressure is the most important treatable factor in preventing HPS in these high risk patients.

  10. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi [Iwate Medical Univ., Morioka (Japan). School of Medicine

    2002-04-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23{+-}10 cm/sec in 21 FDE cases, 14{+-}3 cm/sec in 3 FDL-1 cases, 29{+-}23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58{+-}25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  11. Positron computed tomography studies of cerebral glucose metabolism in man: theory and application in nuclear medicine.

    Science.gov (United States)

    Phelps, M E

    1981-01-01

    The capability of positron computed tomography (PCT) to delineate the substructures of the brain and its facility for accurately measuring the local tissue radioactivity concentration allow the application of tracer kinetic models for the study of local cerebral function in man. This principle and an adaptation of the 14C-deoxyglucose (DG) model of Sokoloff et al. with 18F-2-fluoro-deoxy-D-glucose (FDG) is being used at UCLA. Brookhaven National Laboratory, University of Pennsylvania, NIH, and the Massachusetts General Hospital to determine the local cerebral glucose metabolic rate (LCMRGIc) in normal man at rest and during sensory activation and the changes that occur in patients with a variety of cerebral disorders. Kinetic studies with PCT have been employed to measure the rate constants of the model in different gray and white matter structures of the brain in both normal and ischemic states. The precision of the method in normals has been shown to be about +/- 5% for 1.5-2.0 sq cm regions of the brain. Studies in normals have yielded values for hemispheric CMRGIc that are in agreement with measurement using the Kety-Schmidt technique and LCMRGIc values in agreement with values in monkeys using DG autoradiography. Studies in volunteers subjected to visual and auditory stimulation are demonstrating the potential of this technique for investigating the human brain's response to different stimuli. STudies in patients with stroke show excellent correlation between the degree, extent, and particular structures involved and the clinical symptoms. The method consistently detected hypometabolism in cortical, thalamic, and striatal tissues that were dysfunctional due to deactivation or damage but which appeared normal on x-ray CT. Studies in patients with partial epilepsy have shown hypometabolic zones that highly correlated anatomically with interictal EEG spike foci and were associated with normal x-ray CT studies in 77% of the patients studied. The studies on

  12. SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY STUDY OF REGIONAL CEREBRAL BLOOD FLOW IN PATIENTS WITH HEMISPATIAL NEGLECT

    Institute of Scientific and Technical Information of China (English)

    尹雅芙; 任艳; 李亚明

    2003-01-01

    Objective.To explore the correlations between the occurrence and severity of neglect and the region,range or extent of the decrease in regional cerebral blood flow(rCBF). Methods. Nineteen dextromanual patients who were diagnosed as unilateral stroke clinically and hemispatial neglect by a neglect test battery received single photon emission computed tomography(SPECT) scans. Results. On images,the damages of patients with neglect were seen most frequently in the frontal cortex,and then in turn in the parietal cortex,occipital cortex,temporal cortex,basal ganglia and thalamus. Most patients with neglect had two or more regions damaged. The most significant region was temporal-parietal-occipi-tal(TPO)junction. The correlation coefficient between rCBF and the severity of neglect was -0.34(t=-1.5,P>0.05),and that between the decrease percentage of rCBF and the severity of neglect was 0.34(t=1.47,P>0.05). The correlation coefficients between the range,number of foci,the flow deficit size and the severity of neglect were 0.71(t=4.13,P<0.01),0.70(t=4.07,P<0.01)and 0.64(t=3.40, P<0.01),respectively. Conclusions. The severity of neglect correlates with rCBF and the decrease percentage of rCBF insignificantly,but correlates positively with the range,number of foci and the flow deficit size significantly. Hemispatial neglect is caused by the damage of multiple sites and combined damage results in more severe neglect.

  13. Clinical studies of cerebral circulation using single photon emission computed tomography, 2; Evaluation of cerebral blood flow after acetazolamide loading on moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Toshiro [Gifu Univ. (Japan). Faculty of Medicine

    1993-09-01

    To evaluate cerebral blood flow (CBF) in patients with moyamoya disease, single photon emission computed tomography (SPECT) was performed using acetazolamide-activated {sup 133}Xe inhalation method. In the present investigation, 15 patients were subjected: 6 pediatric cases with the mean age of 10.8 years and 9 adult cases with the mean age of 44.6 years. The regional CBF (rCBF) was measured in the territory of anterior cerebral artery (ACA), middle cerebral artery (MCA), posterior cerebral artery (PCA), basal ganglia, and cerebellum. Cerebrovascular acetazolamide reactivity was evaluated from the rCBF measured before and after administration of acetazolamide. Namely, cerebrovascular acetazolamide reactivity was expressed as %CBF and calculated as follows: %CBF=100 x (CBF after acetazolamide administration-CBF at rest)/CBF at rest. rCBF in adult patients was decreased in the cerebral hemisphere, while that in childhood was significantly decreased in the territory of ACA. The %CBF after acetazolamide loading was decreased in the territory of ACA and MCA in both adult and childhood. When cerebral %CBF was compared to the cerebellar %CBF, the ratio of cerebral %CBF and cerebellar %CBF resulted in markedly lower in childhood than adult. rCBF and cerebrovascular acetazolamide reactivity were also measured before and after extracranial and intracranial (EC-IC) bypass surgery in three pediatric moyamoya patients. Although rCBF was increased immediately after EC-IC bypass surgery, the cerebrovascular acetazolamide reactivity remained blunted. These results meant that in the pediatric moyamoya patients cerebrovascular acetazolamide reactivity is more blunted than adult moyamoya patients. Also, the cerebral vessels in moyamoya disease were considered to be dilated to their limitation by the blood supplied through the EC-IC bypass and not to be expandable any more by acetazolamide. (author) 45 refs.

  14. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the ... of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly ...

  15. Effect of isovolemic, isothermic hemodialysis on cerebral perfusion and vascular stiffness using contrast computed tomography and pulse wave velocity.

    Directory of Open Access Journals (Sweden)

    Ansgar Reising

    Full Text Available BACKGROUND: Patients undergoing hemodialysis treatment have a six-fold increased risk for stroke relative to the general population. However, the effect of hemodialysis on cerebral blood flow is poorly studied and confounding factors like blood pressure and ultrafiltration as well as temperature changes have rarely been accounted for. The aim of our study was to use state-of-the-art technology to evaluate the effect of a single dialysis session on cerebral perfusion as well as on vascular stiffness. METHODS: Chronic hemodialysis patients (7 male/3 female, mean age 58 years were recruited. Cerebral blood flow and arterial pulse wave velocity were measured before and immediately after a hemodialysis session. To exclude effects of volume changes we kept ultrafiltration to a minimum, allowing no change in body weight. Isothermic conditions were maintained by using the GENIUS single-pass batch-dialysis system with a high-flux polysulfone dialyser. Cerebral blood flow was measured by contrast-enhanced computed tomography. Pulse wave velocity was measured using the SphygmoCor (AtCor Medical, USA device by a single operator. RESULTS: This study shows for the first time that isovolemic, isothermic hemodialysis neither affected blood pressure or heart rate, nor total or regional cerebral perfusion. There was also no change in pulse wave velocity. CONCLUSIONS: Mechanisms other than the dialysis procedure itself might be causative for the high incidence of ischemic strokes in this patient population. Moreover, the sole removal of uremic toxins does not lead to short-term effects on vascular stiffness, underlying the importance of volume control in this patient population.

  16. Accuracy of computed tomography perfusion in detecting delayed cerebral ischemia following aneurysmal subarachnoid hemorrhage: A meta-analysis

    Directory of Open Access Journals (Sweden)

    Haogeng Sun

    2013-01-01

    Full Text Available Background and Purpose: In recent years, significant literature shows that computed tomography perfusion (CTP can provide sufficient information on cerebral hemodynamics and effectively indicate delayed cerebral ischemia (DCI before the development of infarction. We aimed at performing a meta-analysis to provide a more full and accurate evaluation of CTP and CTP parameters in detecting DCI in patients with aneurysmal subarachnoid hemorrhage. Materials and Methods: We searched the PubMed, MedLine, Embase and Cochrane databases for analysis published from February 2005 to February 2013. We extracted CTP parameters, including cerebral blood volume (CBV, cerebral blood flow (CBF, mean transit time (MTT, time to peak (TTP, interhemispheric ratios for CBV and CBF and interhemispheric differences for MTT and TTP. Pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR, negative likelihood ratio (NLR, diagnostic odds ratio (DOR and the summary receiver-operating characteristic curve were determined. Results: Four research studies are met the inclusion criteria for the analysis. The pooled sensitivity, specificity, PLR, NLR and DOR of CTP for detecting the DCI were 82%, 82%, 4.56, 0.22 and 20.96, respectively. Through the evaluation of absolute CTP parameters, CBF and MTT showed diagnostic value for DCI, but CBF and TTP did not. Moreover, CBF ratio, MTT difference and TTP difference showed more diagnostic value than CBV ratio in DCI detection by the assessment of relative CTP parameters. Conclusions: As a non-invasive and short time consuming screening method, CTP own a high diagnostic value for the detection of DCI after aneurysm rupture.

  17. Simple partial status epilepticus localized by single-photon emission computed tomography subtraction in chronic cerebral paragonimiasis.

    Science.gov (United States)

    Joo, Eun Yeon; Kim, Jee Hyun; Tae, Woo Suk; Han, Sun Jung; Kim, Seunghwan; Kim, Myoung-Hee; Byun, Hong Sik; Hong, Seung Bong

    2004-10-01

    A patient with chronic cerebral paragonimiasis began to have new motor seizures of the right face manifested by clonic contractions that occurred several hundred times a day, consistent with simple partial status epilepticus. Ictal electroencephalogram discharges started from the left frontal region and then spread to the left hemisphere with left frontal maximum. But clinical seizures were limited to the right face. The frequent partial seizures were controlled by the intravenous infusion of phenytoin. Brain magnetic resonance imaging showed multiple conglomerated round nodules with encephalomalacia in the left temporal and occipital lobes. Applying the technique of ictal-interictal single-photo emission computed tomography subtraction, the authors were able to localize the focal ictal-hyperperfusion on left precentral cortex adjacent to the lesions that correspond to the anatomical distribution of left face motor area.

  18. Alterations of Regional Cerebral Blood Flow in Tinnitus Patients as Assessed Using Single-Photon Emission Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Takashi Ueyama

    Full Text Available Tinnitus is the perception of phantom sound without an external auditory stimulus. Using neuroimaging techniques, such as positron emission tomography, electroencephalography, magnetoencephalography, and functional magnetic resonance imaging (fMRI, many studies have demonstrated that abnormal functions of the central nervous system are closely associated with tinnitus. In our previous research, we reported using resting-state fMRI that several brain regions, including the rectus gyrus, cingulate gyrus, thalamus, hippocampus, caudate, inferior temporal gyrus, cerebellar hemisphere, and medial superior frontal gyrus, were associated with tinnitus distress and loudness. To reconfirm these results and probe target regions for repetitive transcranial magnetic stimulation (rTMS, we investigated the regional cerebral blood flow (rCBF between younger tinnitus patients (<60 years old and the age-matched controls using single-photon emission computed tomography and easy Z-score imaging system. Compared with that of controls, the rCBF of tinnitus patients was significantly lower in the bilateral medial superior frontal gyri, left middle occipital gyrus and significantly higher in the bilateral cerebellar hemispheres and vermis, bilateral middle temporal gyri, right fusiform gyrus. No clear differences were observed between tinnitus patients with normal and impaired hearing. Regardless of the assessment modality, similar brain regions were identified as characteristic in tinnitus patients. These regions are potentially involved in the pathophysiology of chronic subjective tinnitus.

  19. Imaging of Blood Flow in Cerebral Arteries with Dynamic Helical Computed Tomography Angiography (DHCTA) Using a 64-Row CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Pekkola, J.; Kangasniemi, M. (Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2009-08-15

    Background: Cerebral computed tomography angiography (CTA) depicts a structural image of intracranial arteries without providing much time-resolved information on blood flow dynamics. Current CT technology allows obtaining of rapidly repeated helical scans during the arterial contrast filling phase after an intravenous contrast injection. Purpose: To report our experience on dynamic CT imaging in determining the direction of contrast filling within proximal intracranial arteries of operated cerebral artery aneurysm patients. Such dynamic information can help detect vascular occlusion or severe spasm. The method is here referred to as dynamic helical CT angiography (DHCTA). Material and Methods: We retrospectively collected image and related technical data for 23 patients who underwent DHCTA and CTA during their first postoperative day after cerebral artery aneurysm surgery. For DHCTA, we had helically scanned a 4-cm tissue volume three times in succession with a 64-row CT scanner at intervals of 2.6 s during arterial contrast filling after an intravenous contrast injection. We assessed how well DHCTA succeeded in demonstrating the direction of contrast filling in the proximal intracranial arteries, evaluated clinically relevant structural information provided by DHCTA and CTA, and compared radiation doses for the two methods. Results: For 21 patients, DHCTA outlined the direction of contrast filling in proximal intracranial arteries. As to arterial spasm and residual filling of the operated aneurysm, CTA and DHCTA gave similar information. Radiation doses were higher (P<0.000001) for DHCTA than for CTA at 120 kV tube voltage. At 100 kV, the difference was smaller, but doses for DHCTA still exceeded (P<0.05) those for CTA. Conclusion: DHCTA gave dynamic information unobtainable with CTA and could prove useful in selected clinical settings

  20. Computed Tomography (CT) - Spine

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  1. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  2. Demonstration of cerebral vessels by multiplane computed cerebral angiotomography

    Energy Technology Data Exchange (ETDEWEB)

    Asari S.; Satch, T.; Sakurai, M.; Yamamoto, Y. (Matsuyama Shimin Hospital, Matsuyama (Japan)); Sadamoto, K.

    1981-06-01

    1. Cerebral arteries and veins were demonstrated by multiplane computed cerebral angiotomography (combination of axial, modified coronal, half axial (Towne), and semisagittal planes). The vessels which were demonstrated by various planes were as follows: Axial plane: Willis ring, middle cerebral arteries (horizontal and insular portions), anterior cerebral arteries (Horizontal and ascending portions), posterior cerebral arteries, basal vein of Rosenthal, internal cerebral veins (and the subependymal veins which join the ICV), and vein of Galen. Coronal plane: intermal carotid arteries (supraclinoid portion), anterior cerebral arteries (horizontal portion), middle cerebral arteries (horizontal and insular portions), lenticulostriate arteries, basal vein of Rosenthal (and the subependymal veins which join this vessel), internal cerebral veins, and vein of Galen. Half axial plane (Towne projection): basilar artery, vertebral arteries, posterior cerebral arteries, superior cerebellar arteries, middle cerebral arteries (horizontal portion), and anterior cerebral arteries (horizontal and ascending portions). Semisagittal plane: internal carotid artery (supraclinoid portion), posterior communicating artery, posterior carebral artery, superior cerebellar artery, internal cerebral vein, basal vein of Rosenthal, vein of Galen, and straight shinus. 2. A detailed knowledge of normal cerebrovascular structures acquired by computed tomography (CT) is essential in detecting and more precisely localizing lesions such as cerebrovascular disease, neoplasm or abscess, in differentiating these lesions from the normal contrast-enhanced structures, and in understanding the spatial relationship between the mass lesion and the neighboring vessels. In addition, it will be possible to discover such asymptomatic cerebrovascular diseases as non-ruptured aneurysms, arteriovenous malformations, and Moyamoya disease by means of computed cerebral angiotomography.

  3. Cerebral damage following ventricular shunt for infantile hydrocephalus evaluated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, A.; Pasquini, U.; Menichelli, F.; Salvolini, U.

    1981-02-01

    The results of a late CT control of infantile hydrocephalus is reported with an analysis of effects of the catheter on the cerebral tissue in the immediate and late postoperative course. The most frequent finding is blood in the ventricle and/or subependymal or intraparenchymal along the catheter or near its tip.

  4. Two methods for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Kanno, I; Lassen, N A

    1979-01-01

    Two methods are described for calculation of regional cerebral blood flow from completed tomographic data of radioactive inert gas distribution in a slice of brain tissue. It is assumed that the tomographic picture gives the average inert gas concentration in each pixel over data collection periods...

  5. A method for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Celsis, P; Goldman, T; Henriksen, L;

    1981-01-01

    of four 1 min pictures and using a fixed value for the brain:blood partition coefficient, lambda. The method is essentially based on the bolus distribution principle, and it allows the estimation of blood flow in ischemic areas. Application to positron emission tomography is discussed....

  6. Evaluation of therapeutically induced hypertension in patients with delayed cerebral vasospasm by xenon-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Touho, Hajime; Karasawa, Jun; Ohnishi, Hideyuki; Shishido, Hisashi; Yamada, Keisuke; Shibamoto, Keiji (Osaka Neurological Inst., Toyonaka (Japan))

    1992-08-01

    Serial cerebral blood flow (CBF) measurement were made with stable xenon-enhanced computed tomography in 20 patients with angiographically confirmed reputerd intracranial aneurysms, before and during induced hypertension with continuous infusion of dopamine. All patients showed angiogaphic vasospasm during their course. Twelve patients without symptomatic vasospasm (Group 1) had the lowest hemispheric CBF on the craniotomy side of 31.6[+-]6.8 ml/100 gm/min on days 4-9 (control value, 40.1[+-]2.0 ml/100 gm/min), while the other eight patients with symptomatic vasopsasm (Group 2) had the lowest hemispheric CBF on the craniotomy side of 25.0[+-]7.6 ml/100 gm/min on days 10-14. The critical hemispheric CBF inducing neurological deficits was about 20 ml/ 100 gm/min in Group 2. Dysautoregulation was usually present in Groups 1 and 2, but therapeutically induced hypertension could reverse the delayed neurological deficits, it begun early at the stage of delayed vasospasm. (author).

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  8. Early Differential Diagnosis of Rhino-Orbito-Cerebral Mucormycosis and Bacterial Orbital Cellulitis: Based on Computed Tomography Findings

    Science.gov (United States)

    Son, Jun Hyuk; Lim, Hyung Bin; Lee, Soo Hyun; Yang, Jae Wook; Lee, Sung Bok

    2016-01-01

    Purpose To identify significant clinical and radiological findings that distinguish rhino-orbito-cerebral mucormycosis (ROCM) from bacterial orbital cellulitis (BOC). Methods This study was retrospective, multicenter, case-control study that enrolled 34 cases; 14 cases were diagnosed with ROCM and 20 cases were diagnosed with BOC at three different tertiary hospitals between 2005 and 2013. The medical records of all 34 cases were reviewed. The initial clinical manifestations (eyelid swelling, ptosis, extraocular muscle [EOM] limitation, conjunctival injection, and chemosis) and computed tomography (CT) findings (sinus mucosal thickening, full opacification, and air-fluid level) of both diseases were compared. Results Patients with diabetes mellitus (DM) and hypertension (HTN) showed higher incidence rates of ROCM than BOC (DM: p < 0.001, HTN: p = 0.036). ROCM cases exhibited more frequent EOM limitation than cases with BOC (100.0% vs. 66.7%, p = 0.024) but less frequent eyelid swelling (35.7% vs. 90.0%, p = 0.002). However, the incidence rates of ptosis, conjunctival injection, and chemosis exhibited no differences between the diseases. Abnormal CT findings were observed in the sinuses of all patients with ROCM, whereas 12 patients with BOC had sinus abnormalities (100.0% vs. 60.0%, p = 0.011). Thickening of the sinus mucosa was more frequent in patients with ROCM than in those with BOC (92.9% vs. 45.0%, p = 0.009). No significant differences in full opacification or air-fluid level were detected between the groups. Conclusions The differential diagnosis of ROCM and BOC is difficult. Nevertheless, physicians should consider ROCM when a patient with suspected orbital cellulitis presents with EOM limitation without swollen eyelids or thickening of the sinus mucosa on a CT scan. PMID:27501044

  9. The role of additional computed tomography in the decision-making process on the secondary prevention in patients after systemic cerebral thrombolysis

    Directory of Open Access Journals (Sweden)

    Sobolewski P

    2015-12-01

    Full Text Available Piotr Sobolewski,1 Grzegorz Kozera,2 Wiktor Szczuchniak,1 Walenty M Nyka2 1Department of Neurology and Stroke, Unit of Holy Spirit Specialist Hospital in Sandomierz, Sandomierz, Poland; 2Department of Neurology, Medical University of Gdańsk, Gdańsk, Poland Introduction: Patients with ischemic stroke undergoing intravenous (iv-thrombolysis are routinely controlled with computed tomography on the second day to assess stroke evolution and hemorrhagic transformation (HT. However, the benefits of an additional computed tomography (aCT performed over the next days after iv-thrombolysis have not been determined.Methods: We retrospectively screened 287 Caucasian patients with ischemic stroke who were consecutively treated with iv-thrombolysis from 2008 to 2012. The results of computed tomography performed on the second (control computed tomography and seventh (aCT day after iv-thrombolysis were compared in 274 patients (95.5%; 13 subjects (4.5%, who died before the seventh day from admission were excluded from the analysis.Results: aCTs revealed a higher incidence of HT than control computed tomographies (14.2% vs 6.6%; P=0.003. Patients with HT in aCT showed higher median of National Institutes of Health Stroke Scale score on admission than those without HT (13.0 vs 10.0; P=0.01 and higher presence of ischemic changes >1/3 middle cerebral artery territory (66.7% vs 35.2%; P<0.01. Correlations between presence of HT in aCT and National Institutes of Health Stroke Scale score on admission (rpbi 0.15; P<0.01, and the ischemic changes >1/3 middle cerebral artery (phi=0.03 existed, and the presence of HT in aCT was associated with 3-month mortality (phi=0.03.Conclusion: aCT after iv-thrombolysis enables higher detection of HT, which is related to higher 3-month mortality. Thus, patients with severe middle cerebral artery infarction may benefit from aCT in the decision-making process on the secondary prophylaxis. Keywords: ischemic stroke, iv

  10. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Marlies, E-mail: marlies.wagner@kgu.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com [Siemens AG, Health Care Sector (Germany); Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Singer, Oliver C., E-mail: o.singer@em.uni-frankfurt.de [Hospital of Goethe University, Department of Neurology (Germany); Berkefeld, Joachim, E-mail: berkefeld@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany)

    2013-08-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.

  11. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  12. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Tsuzura, Shigenobu [Metropolitan Medical Center of the Severely Handicapped, Fuchu, Tokyo (Japan); Matsuda, Hiroshi

    1995-07-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]-iodoamphetamine ({sup 123}I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author).

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  14. Epileptic patterns of local cerebral metabolism and perfusion in man determined by emission computed tomography of /sup 18/FDG and /sup 13/NH/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.; Engel, J. Jr.; Phelps, M.E.; Selin, C.

    1979-01-01

    Seventeen patients with partial epilepsy had EEG monitoring concurrent with cerebral emission computed tomography (ECT) after /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-ammonia were given intravenously as indicators of local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. In 12 of 15 patients who had unilateral or focal electrical abnormalities, interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20% to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization. These hypometabolic zones appeared normal on x-ray computed tomography in all but three patients and were unchanged on scans repeated on different days. In 5 of 6 patients who underwent temporal lobectomy, the interictal /sup 18/FDG scan correctly detected the pathologically confirmed lesion as a hypometabolic zone, and removal of the lesion site resulted in marked clinical improvement. In contrast, the ictal /sup 18/FDG scan patterns clearly showed foci of increased (82% to 130%) LCMR/sub glc/, which correlated temporally and anatomically with ictal EEG spike foci and were within the zones of interictal hypometabolism (3 studies in 2 patients). /sup 13/NH/sub 3/ distributions paralleled /sup 18/FDG increases and decreases in abnormal zones, but /sup 13/NH/sub 3/ differences were of lesser magnitude. When the relationship of /sup 13/NH/sub 3/ uptake to local blood flow found in dog brain was applied as a correction to the patients' /sup 13/NH/sub 3/ scan data, local alterations in perfusion and glucose utilization were usually matched, both in the interictal and ictal states.

  15. Cerebral blood flow tomography with xenon-133

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, N.A.

    1985-10-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This article discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.

  16. Coronary Computed Tomography Angiography (CTA)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Coronary Computed Tomography Angiography (CCTA) Coronary computed tomography angiography (CCTA) ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  17. Comparison of cerebral blood flow data obtained by computed tomography (CT) perfusion with that obtained by xenon CT using 320-row CT.

    Science.gov (United States)

    Takahashi, Satoshi; Tanizaki, Yoshio; Kimura, Hiroaki; Akaji, Kazunori; Kano, Tadashige; Suzuki, Kentaro; Takayama, Youhei; Kanzawa, Takao; Shidoh, Satoka; Nakazawa, Masaki; Yoshida, Kazunari; Mihara, Ban

    2015-03-01

    Cerebral blood flow (CBF) data obtained by computed tomography perfusion (CTP) imaging have been shown to be qualitative data rather than quantitative, in contrast with data obtained by other imaging methods, such as xenon CT (XeCT) imaging. Thus, interpatient comparisons of CBF values themselves obtained by CTP may be inaccurate. In this study, we have compared CBF ratios as well as CBF values obtained from CTP-CBF data to those obtained from XeCT-CBF data for the same patients to determine CTP-CBF parameters that can be used for interpatient comparisons. The data used in the present study were obtained as volume data using 320-row CT. The volume data were applied to an automated region of interest-determining software (3DSRT, version 3.5.2 ) and converted to 59 slices of 2 mm interval standardized images. In the present study, we reviewed 10 patients with occlusive cerebrovascular diseases (CVDs) undergoing both CTP and XeCT in the same period. Our study shows that ratios of CBF measurements, such as hemodynamic stress distribution (perforator-to-cortical flow ratio of middle cerebral artery [MCA] region) or the left/right ratio for the region of the MCA, calculated using CTP data have been shown to correlate well with the same ratios calculated using XeCT data. These results suggest that such CBF ratios could be useful for generating interpatient comparisons of CTP-CBF data obtained by 320-row CT among patients with occlusive CVD.

  18. Quantifying regional cerebral blood flow by N-isopropyl-P-[I-123]iodoamphetamine (IMP) using a ring type single-photon emission computed tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N.; Odano, I.; Ohkubo, M. [Niigata Univ. (Japan)] [and others

    1994-05-01

    We developed a more accurate quantitative measurement of regional cerebral blood flow (rCBF) with the microsphere model using N-isopropyl-p-[I-123] iodoamphetamine (IMP) and a ring type single photon emission computed tomography (SPECT) system. SPECT studies were performed in 17 patients with brain diseases. A dose of 222 MBq (6 mCi) of [I-123]IMP was injected i.v., at the same time a 5 min period of arterial blood withdrawal was begun. SPECT data were acquired from 25 min to 60 min after tracer injection. For obtaining the brain activity concentration at 5 min after IMP injection, total brain counts collections and one minute period short time SPECT studies were performed at 5, 20, and 60 min. Measurement of the values of rCBF was calculated using short time SPECT images at 5 min (rCBF), static SPECT images corrected with total cerebral counts (rCBF{sub Ct}.) and those corrected with reconstructed counts on short time SPECT images (rCBF{sub Cb}). There was a good relationship (r=0.69) between rCBF and rCBF{sub Ct}, however, rCBF{sub Ct} tends to be underestimated in high flow areas and overestimated in low flow areas. There was better relationship between rCBF and rCBF{sub Cb}(r=0.92). The overestimation and underestimation shown in rCBF{sub Ct} was considered to be due to the correction of reconstructed counts using a total cerebral time activity curve, because of the kinetic behavior of [I-123]IMP was different in each region. We concluded that more accurate rCBF values could be obtained using the regional time activity curves.

  19. Magnetic Resonance Spectroscopy and Single-Photon Emission Computed Tomography in the Evaluation of Cerebral Tumors: A Case Report

    Science.gov (United States)

    Siasios, Ioannis; Valotassiou, Varvara; Kapsalaki, Eftychia; Tsougos, Ioannis; Georgoulias, Panagiotis; Fotiadou, Aggeliki; Ioannou, Maria; Koukoulis, Georgios; Dimopoulos, Vassilios; Fountas, Kostas

    2017-01-01

    In their daily clinical practice, physicians have to confront diagnostic dilemmas which cannot be resolved by the application of only one imaging technique. In this case report, we present a 66-year-old woman who was admitted to our institution for the surgical resection of a recently diagnosed brain tumor. The patient had a history of epileptic seizures and was hospitalized in the past for anti-phospholipid syndrome related to a non-Hodgkin lymphoma in remission. Magnetic resonance imaging (MRI) examination revealed an enhancing right parasagittal lesion with significant edema suggestive of a high grade glioma. Advanced MRI techniques including proton magnetic resonance spectroscopy (1H-MRS) showed findings compatible of glioma. An additional examination was performed as part of a protocol that we are routinely performing in our institution for all brain tumors including not only the gold standard advanced MRI techniques but also single-photon emission computed tomography (SPECT) with technetium-99m (Tc99m). Brain SPECT indicated the presence of a meningioma which was verified by the histopathology of the resected specimen. In conclusion, a multimodality approach for the pre-surgical assessment of brain tumors has significant advantages not only for the diagnosis but also for the evaluation of intracranial tumors histology. PMID:27924180

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  1. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S;

    1983-01-01

    Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used......., and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.......Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used...

  2. Proton computed tomography

    Science.gov (United States)

    Bucciantonio, Martina; Sauli, Fabio

    2015-05-01

    Proton computed tomography (pCT) is a diagnostic method capable of in situ imaging the three-dimensional density distribution in a patient before irradiation with charged particle beams. Proposed long time ago, this technology has been developed by several groups, and may become an essential tool for advanced quality assessment in hadrontherapy. We describe the basic principles of the method, its performance and limitations as well as provide a summary of experimental systems and of results achieved.

  3. Positron Emission Tomography—Computer Tomography Scan Used as a Monitoring Tool Following Cellular Therapy in Cerebral Palsy and Mental Retardation—A Case Report

    Directory of Open Access Journals (Sweden)

    Alok Sharma

    2013-01-01

    Full Text Available Cerebral palsy (CP is one of the non-progressive neurological diseases caused by damage to the brain tissue at birth, which leads to physical, cognitive and perceptive symptoms. Even after lifelong medical and therapeutic management there are residual deficits which affect the quality of life of the patients and their families. We examined a maximally rehabilitated, 20 year old male suffering from CP and Mental Retardation (MR. He had diplegic gait and Intelligence Quotient (IQ score of 44 with affected fine motor activities, balance, speech and higher functions. Positron Emission Tomography—Computer Tomography (PET-CT scan identified frontal, temporal, parietal, occipital, left cerebellar lobes, amygdala, hippocampus, and parahippocampus as the affected areas. He was treated with cellular therapy of Autologous Bone Marrow Derived Mono-Nuclear Cells (MNCs transplantation followed by multidisciplinary rehabilitation. Six months following therapy, PET-CT scan showed significant increase in metabolic activity in all four lobes, mesial temporal structures and left cerebellar hemisphere, also supported by clinical improvement in IQ, social behavior, speech, balance and daily functioning. These findings provide preliminary evidence to support the efficacy of cellular therapy for the treatment of CP with MR. PET-CT scan can also be viewed as an impressive tool to monitor the effects of cellular therapy.

  4. Computer processing of tomography data

    OpenAIRE

    Konečný, Jan

    2011-01-01

    Computer processing of tomography data Tomographs are one of the most important diagnostic devices, which are used in every hospital nowadays; they have already been so for a considerable period of time. The different types of tomographs and the processing of tomographic data and imaging of these data are the subject of this thesis. I have described the four most common types of tomography: X-ray Computed Tomography, Magnetic Resonance Imaging, Positron Emission Tomography and Single Photon E...

  5. Cuantificación del signo de la arteria cerebral media hiperdensa con TCMD Quantification of hyperdense middle cerebral artery sign by multidetector computed tomography (MDCT.

    Directory of Open Access Journals (Sweden)

    Francisco Meli

    2011-12-01

    Full Text Available Objetivos. Obtener una cuantificación absoluta y relativa de la densidad en el signo de la arteria cerebral media (ACM con el fin de lograr un valor objetivo para el diagnóstico temprano de isquemia cerebral aguda con TCMD. Materiales y Métodos. Se incluyeron 40 pacientes, 20 con sospecha de isquemia cerebral aguda (edad media 73,4 años y 20 pacientes controles (edad media 71,2 años, p=0,63, que se realizaron TC cerebral con un equipo de 64 filas de detectores. La cuantificación absoluta se realizó midiendo la densidad en UH en el segmento de la ACM visualmente de mayor densidad. También se midió la densidad en el mismo segmento de la ACM contralateral para calcular la diferencia entre ambas arterias (cuantificación relativa. Resultados. En pacientes casos, la densidad media de la ACM afectada (62,5 UH, IC 99%: 46,2-78,7 fue mayor que la de la ACM contralateral (39,3 UH, IC 99%: 33,3-45,3 (p=0,0004 y también fue mayor en comparación con la ACM en pacientes controles (44,7 UH, IC 99%: 37,4-52 (p=0,0045. En la cuantificación relativa, la diferencia media entre la densidad de la ACM afectada y la de ACM contralateral en los pacientes casos fue de 23,2 UH (IC 95%: 11,7-34,7, mientras que, en pacientes controles, la diferencia media entre la densidad de la ACM derecha y la ACM izquierda fue 5,2 UH (IC 95%: 2,4-8,4 (diferencia: 17,8 UH, p=0,0032, IC 95%: 6,8-28,8. Conclusión. Mostramos diferencias significativas (absolutas y relativas en la densidad de la ACM en pacientes con sospecha de isquemia cerebral aguda en comparación con sujetos normales.Purposes. To obtain absolute and relative quantification values of density in the middle cerebral artery (MCA sign, in order to obtain an objective value for an early diagnosis of acute ischemic stroke using MDCT. Material and Methods. Forty adult patients, 20 with suspected diagnosis of acute ischemic stroke (mean age: 73.4 years and 20 controls (mean age: 71.2 years, p=0.63, underwent brain

  6. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  7. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  8. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  9. Abdominal perfusion computed tomography.

    Science.gov (United States)

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  10. Cerebral air embolism as a complication of computed tomography-guided marking of the lung: depiction of air inflow route from a pulmonary vein to the left atrium.

    Science.gov (United States)

    Higashino, Takanori; Noma, Satoshi; Nishimoto, Yuko; Endo, Junki; Taguchi, Yoshio; Shindo, Toru

    2011-02-01

    Air embolism in the arterial system is a very rare but potentially fatal complication of percutaneous transthoracic needle biopsy or marking. We report a case of a patient with interstitial pneumonia associated with Sjögren syndrome, who presented with systemic arterial air embolism as a complication of computed tomography-guided marking of the lung. The air inflow route was depicted clearly on computed tomography from the peripheral pulmonary vein that crossed the needle pathway to the left atrium.

  11. Regional cerebral blood flow assessed by 133Xe inhalation and emission tomography

    DEFF Research Database (Denmark)

    Shirahata, N; Henriksen, L; Vorstrup, S

    1985-01-01

    Regional cerebral blood flow (rCBF) in the cerebral hemispheres and the cerebellum was measured by single photon emission computed tomography with inhalation of 133Xe in 39 normal volunteers at test. The goal of this study was to assess the normal flow pattern and its variations. Five parallel...

  12. Forensic postmortem computed tomography

    DEFF Research Database (Denmark)

    Jakobsen, Lykke Schrøder; Lundemose, Sissel; Banner, Jytte

    2016-01-01

    PURPOSE: The purpose of this study was to investigate the utility of postmortem computed tomography (PMCT) images in estimating organ sizes and to examine the use of the cardiothoracic ratio (CTR). METHODS: We included 45 individuals (19 females), who underwent a medico-legal autopsy. Using...... the computer software program Mimics(®), we determined in situ heart and liver volumes derived from linear measurements (width, height and depth) on a whole body PMCT-scan, and compared the volumes with ex vivo volumes derived by CT-scan of the eviscerated heart and liver. The ex vivo volumes were also...... differences. CONCLUSIONS: Noninvasive in situ PMCT methods for organ measuring, as performed in this study, are not useful tools in forensic pathology. The best method to estimate organ volume is a CT-scan of the eviscerated organ. PMCT-determined CTR seems to be useless for ascertaining cardiomegaly...

  13. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  14. Sensitivity of 3D gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography angiography for detection of middle cerebral artery thrombus in acute stroke

    Directory of Open Access Journals (Sweden)

    Amit Agarwal

    2014-11-01

    Full Text Available We aimed at comparing the sensitivity of magnetic resonance (MR susceptibility-weighted imaging (SWI with computed tomography angiography (CTA in the detection of middle cerebral artery (MCA thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI and CTA. Twenty random subjects with completely normal MRI (including SWI exam were selected as control. Two neuroradiologists (blinded to the presence or absence of stroke reviewed the SW images and then compared the findings with CT angiogram (in patients with stroke. The number of MCA segments showing thrombus in each patient was tabulated to estimate the thrombus burden. Thrombus was detected on SWI in one or more MCA segments in 30 out of 35 patients, on the first review. Of the 30, SWI showed thrombus in more than one MCA segments in 7 patients. CTA depicted branch occlusion in 31 cases. Thrombus was seen on both SWI and CTA in 28 patients. Thrombus was noted in two patients on SWI only, with no corresponding abnormality seen on CTA. Two patients with acute MCA showed no vascular occlusion or thrombus on either CTA or SWI. Only two case of false-positive thrombus was reported in normal control subjects. Susceptibility-weighted images had sensitivity and specificity of 86% and 90% respectively, with positive predictive value 94%. Sensitivity was 86% for SWI, compared with 89% for CTA, and this difference was statistically insignificant (P>0.05. Of all the positive cases on CTA (31 corresponding thrombus was seen on SWI in 90% of subjects (28 of 31. Susceptibility-weighted imaging has high sensitivity for detection of thrombus in acute MCA stroke. Moreover, SWI is a powerful technique for estimation of thrombus burden, which can be challenging on CTA.

  15. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  16. Metrizamide computed tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, T.; Tamakawa, Y.; Arii, H. (Akita Univ. (Japan). Faculty of Medicine); Takahashi, M.; Hirota, K.

    1981-11-01

    Serial computed tomography of the cervical cord was performed following metrizamide myelography in five cases of clinically suspected syringomyelia. The syrinx filled with refluxed metrizamide was demonstrated in all of the cases. The reflux of metrizamide into the syrinx was most marked several hours following intrathecal injection of metrizamide. Computed tomography combined with metrizamide myelography is essential in the diagnosis of communicating syringomyelia.

  17. Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

    Directory of Open Access Journals (Sweden)

    Dietrich Jehle

    2012-02-01

    Full Text Available CT angiography (CTA has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms.

  18. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  1. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  2. Computed tomography in neuronal ceroid lipofuscinosis

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neuronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter.

  3. The role of additional computed tomography in the decision-making process on the secondary prevention in patients after systemic cerebral thrombolysis

    OpenAIRE

    2015-01-01

    Piotr Sobolewski,1 Grzegorz Kozera,2 Wiktor Szczuchniak,1 Walenty M Nyka2 1Department of Neurology and Stroke, Unit of Holy Spirit Specialist Hospital in Sandomierz, Sandomierz, Poland; 2Department of Neurology, Medical University of Gdańsk, Gdańsk, Poland Introduction: Patients with ischemic stroke undergoing intravenous (iv)-thrombolysis are routinely controlled with computed tomography on the second day to assess stroke evolution and hemorrhagic transformation (HT). However, the...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  8. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  9. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  10. Clinical study on the cardiac hemodynamics and the possibility of demonstration of the left intraatrial thrombi by echocardiography, angiocardiography and computed tomography and the neurological symptoms in patients with heart disorder and cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kazuo

    1987-03-01

    In an attempt to elucidate risk factors for developing cerebral embolism (CE) in patients with heart disease, hemodynamic, sonographic or radiologic, and neurologic manifestations of heart disease developing into CE were retrospectively analyzed in 44 patients with CE and 122 patients with mitral valve disease (MVD). The most common underlying disease of CE was valve disease (50 %), followed by myocardial infarction, atrial fibrillation, and infectious endocarditis. In MVD patients, risk factors for CE were considered to be atrial fibrillation, mitral stenosis, and intraatrial thrombi. Combined use of various imaging modalities revealed the presence of intraatrial thrombi in 65 % of the CE patients. Cranial computed tomography showed hemorrhagic infarction in 22 %, and found the mid-arotic artery to be the commonest responsible region (81 %). The frequent initial neurologic symptom was hemiplegia. Half of the patients had disturbance of consciousness on admission. Prognosis was better in patients with MVD than those with the other types of heart disease. (Namekawa, K.). 117 refs.

  11. Evaluation of computer tomography in cerebro-vascular disease (Strokes)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Sik; Baek, Seung Yon; Rhee, Chung Sik; Kim, Hee Seup [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1984-06-15

    Most of cerebrovascular disease are composed of vascular occulusive changes and hemorrhage. Now a day, the computed tomography is the best way for evaluation of cerebrovascular disease including detection of nature, location, and associated changes. This study includes evaluation of computed tomography of 70 patients with cerebrovascular disease during the period of 10 months from April. 1983 to Feb. 1984 in Department of Radiology, Ewha Womans University Hospital. The results were as follows: 1. Age distribution of the total 70 patients was broad ranging from 25 years to 79 years. 78.6% of patients were over the age of 50. The male and female sex ratio was 1.4:1. 2. 4 out of 70 patients were normal and 66 patients revealed abnormal on C.T. findings; those were intracranial hemorrhage (28 patients), cerebral infarction (34 patients) and brain atrophy (4 patients). 3. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (28 cases), and next was basal ganglia (2 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. 4. In cases of intracranial hemorrhage, the basal ganglia was most common site of lesion (15 cases). The next common site was cerebral hemisphere (9 cases). 6 patients of all intracranial hemorrhage were combined with intraventricular hemorrhage. Ratio of right and left was 2:3. 5. In patients with motor weakness or hemiparesis, more common findings on CT scan were cerebral infarction. In case with hemiplegia, more common CT findings were intracerebral hemorrhage. 6. Of the 40 cases thought to be cerebral infarction initially by clinical findings and spinal tap. 8 cases (20.0%) were proved to be cerebral hemorrhage by the CT scan. However, of the 22 cases thought to be cerebral hemorrhage, initially, only two cases (9.0%) were cerebral infarction.

  12. Computed tomography of the brain in kwashiorkor: a follow up study.

    OpenAIRE

    Househam, K C

    1991-01-01

    Computed tomography of the brain was performed initially and after nutritional rehabilitation on 12 children with kwashiorkor. The severe cerebral shrinkage evident initially resolved after nutritional rehabilitation. The mechanism and significance of this reversible abnormality remains to be determined.

  13. Studies of computed tomography as a contribution to differential diagnosis between dementia due to cerebrovascular disease (multi-infract type) and due to primarily degenerative cerebral atrophy (Alzheimers type)

    Energy Technology Data Exchange (ETDEWEB)

    Kohlmeyer, K.

    Studies of computed tomography were performed in 367 patients diagnosed as dementia clinically. The mean age was 70.1 years. By the clinicians 240 were classified as senile dementia of Alzheimer's type, 79 as multiinfarct dementia, and 48 were not determined definitely. In 3%, the CT studies did detect treatable causes like tumors, subdural hematomas and communicating hydrocephalus. In about 57% was found by CT a diffuse brain atrophy without focal tissue changes as to expect if occurring a cerebrovascular disease. In 25% there were focal changes of the brain tissue in CT to define as residuals of infarctions in addition to the signs of cerebral atrophy. The results of the CT studies were normal in 15% despite the evidence of dementia clinically. The analysis of the material did show that a cerebrovascular disease as a cause of dementia is suspected clinically in much more cases than CT studies are able to prove focal pathological changes of the brain tissue due to disorders of cerebral blood flow.

  14. Findings of computed tomography in intracranial tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H. G.; Bae, K. S.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    In intracranial tuberculosis, the Computed Tomography (CT) is a new radiological technique which is helpful in diagnosis and determining the location, extents of the lesion. It can also make it possible to assess the presence and degree of the complications and to evaluate the effectiveness of treatment. 25 cases of clinically proven intracranial tuberculosis were studied by CT, in Soonchunhyang hospital from Jun. 1980 to Jun. 1983. The result were as follows; 1. 4 cases were normal in CT finding, despite of the clinically proven tuberculous meningitis. 2. Total or partial obliteration of cisterns were observed in 13 cases. 3. Intense abnormal contrast enhancement of the cisterns were observed in 8 cases. 4. 19 cases show moderate to marked ventricular dilatation. 5. 2 cases of cerebral infarction were observed. 6. One case of tuberculoma was observed.

  15. Evaluation of multislice computed tomographic perfusion imaging and computed tomographic angiography on traumatic cerebral infarction

    Institute of Scientific and Technical Information of China (English)

    XU Fang-hong; CHEN Wei-jian; YANG Yun-jun; DUAN Yu-xia; FU Feng-li

    2008-01-01

    Objective: To evaluate the application value of multislice computed tomographic perfusion imaging (MSCTPI) and multislice computed tomographic angiography (MSCTA) on traumatic cerebral infarction. Methods: MSCTA was performed on 10 patients who were initiailly diagnosed as traumatic cerebral infarction by normal conventional computed tomography (NCCT), among whom, 3 patients were examined by MSCTPI simultaneously. Reconstructed images of the intracranial artery were made with techniques of maximum intensity projection (MIP) and volume rendering (VR) from MSCTA scanning data. Then the graph of function of four parameters, regional cerebral blood flow (Rcbf), regional cerebral blood volume (Rcbv), mean transit time (MTT), and time to peak (TTP), acquired by the perfusing analysis software was obtained. Results: Among the 10 patients with traumatic cerebral infarction, 6 showed complex type on NCCT, which depicted abnormality on MSCTA, and 4 showed simple type on NCCT, which had negative results on MSCTA. Among the 4 patients with abnormal great vessels, 2 suffered from steno sis or occlusion of the middle cerebral artery, 1 from spasm of the anterior cerebral artery, and 1 from spasm of the vertebral-basal artery. The image of MSCTPI of 1 patient with massive cerebral infarction on the right cerebral hemisphere confirmed by CT was smaller than those of the other patients, which showed occlusion of the ipsilateral middle cerebral artery on MSCTA. Among the 6 patients whose MSCTA showed no abnormality, 4 showed simple infarction and 2 showed complex infarction. The infarction focus of 5 patients occurred in the basal ganglia and 1 in the splenium of corpus callosum. Among the 2 cases of small cerebral infarction volume on NCCT, one was normal, the other showed hypoperfusion on MSCTPI and was normal on MSCTA. Conclusion: The combination of MSCTPI and MSCTA is very useful for evaluating the change of intracranial artery in ischemic regions and assessing the cerebral

  16. Right parietal stroke with Gerstmann's syndrome. Appearance on computed tomography, magnetic resonance imaging, and single-photon emission computed tomography.

    Science.gov (United States)

    Moore, M R; Saver, J L; Johnson, K A; Romero, J A

    1991-04-01

    We examined a patient who exhibited Gerstmann's syndrome (left-right disorientation, finger agnosia, dyscalculia, and dysgraphia) in association with a perioperative stroke in the right parietal lobe. This is the first description of the Gerstmann tetrad occurring in the setting of discrete right hemisphere pathologic findings. A well-localized vascular lesion was demonstrated by computed tomography, magnetic resonance imaging, and single-photon emission computed tomographic studies. The patient had clinical evidence of reversed functional cerebral dominance and radiologic evidence of reversed anatomic cerebral asymmetries.

  17. Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms - a comparative study with DSA and TOF-MRA

    Energy Technology Data Exchange (ETDEWEB)

    Buhk, Jan-Hendrik; Kallenberg, Kai [University of Goettingen, Department of Neuroradiology, Goettingen (Germany)]|[University of Goettingen, MR-Research in Neurology and Psychiatry, Goettingen (Germany); Mohr, Alexander; Knauth, Michael [University of Goettingen, Department of Neuroradiology, Goettingen (Germany); Dechent, Peter [University of Goettingen, MR-Research in Neurology and Psychiatry, Goettingen (Germany)

    2009-02-15

    Following coil embolization of intracranial aneurysms, many centers perform at least one digital subtraction angiography (DSA) continuing with time-of-flight magnetic resonance angiography (TOF-MRA). Angiographic computed tomography (ACT) provides high-resolution data from a rotational acquisition of a c-arm-mounted flat panel detector. This study evaluates possible advantages of applying ACT in aneurysm follow-up. In 22 patients DSA examinations with a rotational acquisition were performed. Rotational data were processed into an isotropic high-resolution volume. TOF-MRA was performed the day before DSA. Three experienced neuroradiologists performed a rating of the occlusion rate and a subjective method comparison. Weighted {kappa} statistics were calculated to assess the level of interobserver agreement. Compared to DSA, the diagnostic value of ACT as well as of TOF-MRA was rated to be inferior, although the sensitivity of detecting residual necks was higher with both techniques. Compared to TOF-MRA, ACT achieves favorable ratings only in aneurysms after stent-remodeling. Interobserver agreement was high for all techniques. Ratings of the occlusion rate correlated highly between all observers (r > 0.85, p < 0.001, respectively). In selected patients ACT can add valuable diagnostic information to DSA. TOF-MRA remains a highly sensitive method for aneurysm follow-up. (orig.)

  18. Decreased light attenuation in cerebral cortex during cerebral edema detected using optical coherence tomography

    OpenAIRE

    Rodriguez, Carissa L. R.; Szu, Jenny I.; Eberle, Melissa M.; Wang, Yan; Hsu, Mike S.; Binder, Devin K.; Park, B. Hyle

    2014-01-01

    Abstract. Cerebral edema develops in response to a variety of conditions, including traumatic brain injury and stroke, and contributes to the poor prognosis associated with these injuries. This study examines the use of optical coherence tomography (OCT) for detecting cerebral edema in vivo. Three-dimensional imaging of an in vivo water intoxication model in mice was performed using a spectral-domain OCT system centered at 1300 nm. The change in attenuation coefficient was calculated and cere...

  19. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  20. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.;

    2014-01-01

    contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial......The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  1. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    Modern diagnostic imagining techniques are gaining popularity in forensic medicine. Denmark has been involved in the development of this use of imaging techniques from the beginning. The Institute of Forensic Medicine at the University of Southern Denmark acquired a helical computed tomography (CT...... AND METHODS: This thesis investigated 900 forensic cases that were CT-scanned and autopsied at the Institute of Forensic Medicine, University of Southern Denmark, from 2006-2011. The scanner was a Siemens Somatom Spirit dual-slice CT-scanner with a Siemens Syngo MultiModality workstation. Contrast enhancement...

  2. APPLICATION OF SINGLE PHOTON EMMISSION COMPUTED TOMOGRAPHY TO CLINICAL STUDY ON THE THERAPEUTIC EFFECT OF ACUPUNCTURE IN TREATMENT OF CHILD CEREBRAL PARALYSIS

    Institute of Scientific and Technical Information of China (English)

    于海波; 鞠琰莉; 贾少微

    2001-01-01

    Subjective: To identify the practicability and clinical values of acupuncture in the treatment of child cerebral paralysis, try to provide visualized evidence and mechanisms for acupuncture treatment of this disease. Methods: 13 cerebral palsy children including 9 cases of spasmodic type, 2 cases of ataxia type and 2 cases of mixed type, 9 males and 4 females were subjected into this study. Acupoints used were Hegu (LI 4), Quchi (LI 11 ), Zusanli (ST 36) and Sanyinjiao (SP 6) that were punctured and stimulated electrically with parameters of frequency 2/15 Hz, electric current 5 mA, and duration of stimulation 30 min. Under monitoring of Siemens ECAM/ICON SPECT System, blood flow volumes of different brain regions were observed before, during and after elctroacupuncture (EA) stimulation of the above-mentioned acupoints. Results: SPECT revealed that in these 13 infantile patients, 18 regions of the brain in-cluding 12 in the frontal lobe and 6 in the temporal lobe presented insufficiency of blood perfusion and hypofunction; during EA, these cerebral regions and parietal lobe, visual cortex, thalamus, basal ganglion and cerebellum showed improvement in blood perfusion and function in different degrees. Results of the quantitative analysis on blood flow function changing rate (BFCR)% showed a significant increase in 83.3 % of the focal regions during EA. Conclusion: Acupuncture therapy can effectively improve cerebral blood perfusion of the focus and is of clinical value in treatment of infantile cerebral paralysis.

  3. Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling.

    Science.gov (United States)

    Zolgharni, M; Ledger, P D; Armitage, D W; Holder, D S; Griffiths, H

    2009-06-01

    Magnetic induction tomography (MIT) is a new electromagnetic imaging modality which has the potential to image changes in the electrical conductivity of the brain due to different pathologies. In this study the feasibility of detecting haemorrhagic cerebral stroke with a 16-channel MIT system operating at 10 MHz was investigated. The finite-element method combined with a realistic, multi-layer, head model comprising 12 different tissues, was used for the simulations in the commercial FE package, Comsol Multiphysics. The eddy-current problem was solved and the MIT signals computed for strokes of different volumes occurring at different locations in the brain. The results revealed that a large, peripheral stroke (volume 49 cm(3)) produced phase changes that would be detectable with our currently achievable instrumentation phase noise level (17 m degrees ) in 70 (27%) of the 256 exciter/sensor channel combinations. However, reconstructed images showed that a lower noise level than this, of 1 m degrees , was necessary to obtain good visualization of the strokes. The simulated MIT measurements were compared with those from an independent transmission-line-matrix model in order to give confidence in the results.

  4. Future of cardiac computed tomography

    Institute of Scientific and Technical Information of China (English)

    Carlo N De Cecco; U Joseph Schoepf

    2015-01-01

    Coronary computed tomography angiography(CCTA)has become an integral tool in the noninvasive diagnostic workup of patients with suspected coronary artery disease in both elective and emergency settings. Today, it represents a mature technique providing accurate, non-invasive morphological assessment of the coronary arteries and atherosclerotic plaque burden. Iterative reconstruction algorithms, low kV imaging, and single-heart beat acquisitions hold promise to further reduce dose requirements and improve the safety and robustness of the technique in several circumstances including imaging of heavily calcified vessels, patients with morbid obesity or irregular heart rates, and assessment in the emergency setting. However, it has become clear over recent years that cardiac radiologists need to take further steps towards the development and integration of functional imaging with morphological CCTA assessment to truly provide a comprehensive evaluation of the heart. Computed tomography myocardial perfusion imaging, including both dynamic and static dual-energy approaches, has demonstrated the ability to directly assess and quantify myocardial ischemia with simultaneous CCTA acquisition with a reasonable contrast medium volume and radiation dose delivered to the patient. In order to promote CCTA in the clinical and research environments, radiologists should prepare to embrace the change from morphological to functional imaging, furnishing all the necessary resources and information to referring clinicians.

  5. Cranial computed tomography in psychiatry. Kraniale Computertomographie in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Falkai, P. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany)); Bogerts, B. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany))

    1993-08-13

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.)

  6. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  7. Study on cerebral microcirculation by Optical Doppler Tomography

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale. Rats with cranial window are used as a model, and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system, under electrical stimulation and drug administration. The results show significant differences in the blood flow velocity between experimental groups and control groups, demonstrating the feasibility of ODT in the cerebral microcircula- tion study. Compared with the conventional Doppler ultrasound, ODT provides much higher spatial resolution, and thus holds a promising future in the application of the cerebral microcirculation study, especially in the observation of the blood flow velocity in micrometer scale vessels.

  8. Study on cerebral microcirculation by Optical Doppler Tomography

    Institute of Scientific and Technical Information of China (English)

    MENG Jie; DING ZhiHua; YANG Yong; GUO ZhouYi

    2008-01-01

    Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale.Rats with cranial window are used as a model,and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system,under electrical stimulation and drug administration.The results show significant differences in the blood flow velocity between experimental groups and control groups,demonstrating the feasibility of ODT in the cerebral microcircula-tion study.Compared with the conventional Doppler ultrasound,ODT provides much higher spatial resolution,and thus holds a promising future in the application of the cerebral microcirculation study,especially in the observation of the blood flow velocity in micrometer scale vessels.

  9. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  10. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  11. Computed tomography of the gallbladder.

    Science.gov (United States)

    Havrilla, T R; Reich, N E; Haaga, J R; Seidelmann, F E; Cooperman, A M; Alfidi, R J

    1978-06-01

    Computed tomography (CT) was used to study 79 patients with suspected gallbladder disease. First and second generation scanners were used to determine the efficacy of CT in detecting cholecystitis or cholelithiasis. Manifestations of gallbladder disease such as hydrops, opaque and nonopaque gallstones, chronic cholecystitis with thickened inflammatory walls, and secondary liver abscesses can be easily detected. It is a useful technique for individuals in whom the gallbladder has failed to opacity on oral cholecystography. The scanning method is described, and estimates of reliability are given including its accuracy, limitations, and place in the management of gallbladder disease, especially cholelithiasis. When conventional radiographic examinations or ultrasound fail to give definitive diagnostic information, CT can be a useful alternative with an overall diagnostic accuracy greater than 80%.

  12. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  13. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  14. Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun-Suk; Chung, Tae-Sub; Baek, Jang Hun; Suh, Sang Hyun [Gangnam Severance Hospital, Department of Radiology, Yonsei University College of Medicine, Gangnam-gu, Seoul (Korea, Republic of); Ahn, Sung Jun [Severance Hospital, Department of Radiology, Yonsei University College of Medicine, Seodaemun-gu, Seoul (Korea, Republic of); Chong, KyoungHoon [Siemens Healthcare Korea, Seodaemun-gu, Seoul (Korea, Republic of)

    2015-05-01

    To determine the feasibility of using a 70-kVp protocol compared with a 120-kVp protocol for cerebral CT angiography. An additional target was to investigate a possible reduction in the volume of contrast medium (CM) using the 70-kVp protocol. Attenuation value and CNR for iodine were determined at various tube voltage settings using a phantom. Sixty-nine volunteers were randomly assigned to one of three protocols: group A (120-kVp and CM 64 mL), group B (70-kVp and CM 64 mL), or group C (70-kVp and CM 40 mL). The attenuation value, SNR, and CNR of cerebral arteries, subjective image quality, and radiation dose were compared among the groups. The vascular attenuation, SNR, and CNR of group B were significantly higher than those of group A. Group C had a significantly higher vascular attenuation than group A. Groups B and C were significantly better than group A with respect to subjective image quality. An effective dose of 70-kVp was 10 % lower than that of 120-kVp. Using 70-kVp improved arterial enhancement, SNR, and CNR, and provided better subjective image quality, using a 10 % lower effective dose. Furthermore, the 70-kVp protocol may both reduce volume of CM by 37.5 % and improve arterial enhancement. (orig.)

  15. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  16. Prognostic value of reduced discrimination and oedema on cerebral computed tomography in a daily clinical cohort of out-of-hospital cardiac arrest patients

    DEFF Research Database (Denmark)

    Langkjær, Sandra; Hassager, Christian; Kjaergaard, Jesper

    2015-01-01

    bleeding' in 4(3%), 'new cerebral infarction' in 10(7%), and 'reduced discrimination between white and grey matter and/or oedema' in 45(30%) patients. 'Reduced discrimination and/or oedema' by late cCT was independently associated with higher 30-day mortality compared to patients with a normal late CT (HR......(adjusted) = 2.6 (95%CI: 1.4-4.8, p = 0.002). CONCLUSION: Our observations suggest that a cCT may be useful as part of the neurological prognostication in patients with OHCA. 'Reduced discrimination between white and grey matter and/or oedema' on cCT was independently associated with a poor prognosis....

  17. Spiral computed tomography angiography (SCTA) and color coded duplex ultrasound (CCDUS): two complementary diagnostic techniques for assessment of extracranial cerebral artery stenosis.

    Science.gov (United States)

    Scaroni, Reana; Cardaioli, Gabriela; Pelliccioli, Gian Piero; Gallai, Virgilio

    2002-01-01

    Atherosclerotic lesions of the extracranial cerebral arteries account for ischemic stroke in over half of all cases. The risk of stroke associated with symptomatic carotid artery disease is related to the severity of the stenosis. Results of the two major clinical trials, North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST), showed that patients with symptomatic carotid artery disease may benefit from carotid endarterectomy. Therefore, detection and quantification of stenosis are essential. Discrepancies in the angiographic criteria used in both NASCET and ECST trials resulted in continued controversy about the most accurate method of measuring carotid artery stenosis. Moreover, to avoid complications related to the angiography procedure, a good evaluation of vessel wall and plaque composition need to be considered. Both SCTA and CCDUS are non invasive techniques that could overcome angiographic complications and give detailed information on stenosis grading and plaque characteristics. They have been used to evaluate carotid stenosis as a single or combined methods.

  18. Computed tomography of sellar and parasellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Mitsunori; Aoki, Hideo (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1982-06-01

    Neuroradiological modalities, particularly CT, for sellar and parasellar lesions were reviewed. Although accurate preoperative diagnosis is sometimes difficult, CT diagnosed 83% as far as pituitary adenoma, craniopharyngioma and meningioma were concerned and demonstrated abnormal findings in 95% of parasellar tumors. At the authors' department, CT visualized abnormalities in all cases, with the exception of suprasellar arachnoid cyst, but a histological diagnosis was possible only in 84%. Since lesions including tumors cannot be completely denied even if CT shows normal images, findings by modalities such as plain craniography, cerebral tomography, cerebral angiography and cisternography should be judged comprehensively.

  19. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  20. 重型颅脑外伤灌注CT结果与脑灌注压的相关性%Correlation of brain perfusion computed tomography results and cerebral perfusion pressure in patients with severe head trauma

    Institute of Scientific and Technical Information of China (English)

    徐裕; 冯东侠; 高恒; 那汉荣; 徐伟东; 周新民

    2012-01-01

    目的 探讨重型颅脑外伤患者灌注CF结果与脑灌注压监测结果的相关性.方法 50例重型颅脑外伤患者分为两组:T组28例,C组22例,人院时头颅CT平扫有明显异常.在行灌注CT时,同时监测平均动脉压(MAP)及颅内压(ICP),计算脑灌注压(CPP).应用直线回归分析灌注CT参数[局部脑血容量(rCBV)、局部脑血流(rCBF)和平均通过时间(MTT)]与CPP的相关性.结果 根据灌注CT结果,T组分为两个亚组:T1组,16例,灌注CT结果与CPP呈弱相关;T2组,12例,两者存在强相关.T1、T2和C组间的灌注CT参数均有明显差异.T1组的rCBF为(18.8±8.0)cm3·100g1·min-2,明显低于T2组的(60.2±21.3)cm3·100g1·min-1和C组的(48.3±11.0)CM3·100g1·min-1(P<0.01).T1、T2组灌注CT参数与相应CPP值之间均显著相关(P<0.01).结论 灌注CT结合ICP监测能提供有价值的评估脑血管自动调节功能是否完好的信息,有助于指导治疗.%Objective To investigate the correlation of brain perfusion computed tomography (CT) results and cerebral perfusion pressure (CPP) in patients with severe head trauma. Methods Perfusion CT results of 50 patients with head trauma were analyzed , who were divided into two groups of T(28 cases, severe head trauma with abnormal CT findings during admission) and C(22 cases,head trauma with normal CT findings during admission). The patients underwent perfusion CT and MAP and ICP were measured at the same time, by which CPP was calculated. The correlation between perfusion CT results [regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF) and MTT] and corresponding CPP was analyzed using linear regression analysis. Results According to perfusion CT results, group T was divided into two subgroups of Tl (16 cases, characterized by a weak correlation between the perfusion-CT results and the corresponding CPP values) and T2(12 cases,characterized by a strong correlation between the perfusion-CT results and the corresponding

  1. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  2. Computed tomography of arachnoid cyst

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Min Gi; Bae, Weon Tae; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyun De [College of Medicine, Chonnam National University, Kwangju (Korea, Republic of)

    1988-02-15

    The preoperative diagnosis of intracranial arachnoid cysts has been simplified, and made more rapid and accurate with computed tomography (CT). Using CT cisternography, detailed anatomic and physiologic information of arachnoid cysts could be obtained. CT features of pathologically proven 21 arachnoid cysts that were examined at Chonnam National University Hospital from June 1983 to May 1987 were analyzed. The results were as follows: 1.Prevalent age group was the 1st decade (8 cases) and male to female ratio was 17:4. 2.Clinical features were related to the location of arachnoid cyst, common symptoms were headache (53.3%), convulsion, mental change and walking disturbance. 3.Location of the arachnoid cyst were in supratentorial region (15 cases) most in middle cranial fossa (12 cases), and infratentorial region (6 cases), common at the retrocerebellar cisternal space (3 cases). 4.Shapes of arachnoid cyst were biconvex with straight inner margin (8 cases), spherical (7 cases), simple biconvex (3 cases) and others (3 cases). 5.Size of the arachnoid cyst, in the greatest dimension, was ranged from 2cm to 9cm and commonly distributed between 3cm to 5cm (14 cases). 6.Of all 14 cases, who did CT cisternography using metrizamide (11 cases) and iopamidol (3 cases), 2 cases had communication with the subarachnoid space.

  3. Quantitation of regional cerebral blood flow by single photon emission computed tomography of CBF-tracer combined with whole-brain CBF; A comparison between [sup 123]I-IMP and [sup 99m]Tc-HMPAO in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Isaka, Yoshinari; Imaizumi, Masatoshi; Ashida, Keiichi; Ohe, Yosuke; Okamoto, Masaya; Abe, Tohru; Tanaka, Seiji (Osaka National Hospital (Japan))

    1994-05-01

    A simple, noninvasive method of measuring cerebral blood flow (CBF) that uses single-photon emission computed tomography (SPECT) of CBF-tracer and whole brain CBF obtained by xenon-133 ([sup 133]Xe) clearance technique was developed. In nine healthy volunteers, SPECT data were normalized to the count density of [sup 123]I-IMP or [sup 99m]Tc-HMPAO uptake in the whole-brain, and then converted to the absolute units of CBF by multiplying average [sup 133]Xe-CBF in the whole brain. The CBF values measured by [sup 99m]Tc-HMPA CBF-SPECT was significantly lower in the high flow regions of cortical gray matter (bilateral frontal lobe; p<0.05 and right occipital lobe; p<0.05), and was significantly higher in the bilateral white matter (p<0.05 or 0.01) and the cerebellum (p<0.005) compared with the flow values measured by [sup 123]I-IMP CBF-SPECT. Whereas, the IMP-CBF values were significantly lower in the bilateral striatum (p<0.02 or 0.05) compared with the HMPAO-CBF values. Good correlations were found between IMP-CBF and the HMPAO-CBF values in the cortical gray matter (r[sub s]=0.761; p<0.001, n=108), the white matter (r[sub s]=0.739; p<0.001, n=18) and the cerebellum (r[sub s]=0.731; p<0.001, n=18). In the striatum (r[sub s]=0.58; p<0.05, n=18) and the thalamus (r[sub s]=0.628; p<0.05, n=18), the correlations between IMP-CBF and HMPAO-CBF values were inferior to those of the other three regions. The results indicated that the contrast between high and low CBF regions in the HMPAO CBF-SPECT was significantly less than that in the IMP CBF-SPECT. However, this assumption is not applicable in all of the cerebral regions. (author).

  4. A large web-based observer reliability study of early ischaemic signs on computed tomography. The Acute Cerebral CT Evaluation of Stroke Study (ACCESS.

    Directory of Open Access Journals (Sweden)

    Joanna M Wardlaw

    Full Text Available BACKGROUND: Early signs of ischaemic stroke on computerised tomography (CT scanning are subtle but CT is the most widely available diagnostic test for stroke. Scoring methods that code for the extent of brain ischaemia may improve stroke diagnosis and quantification of the impact of ischaemia. METHODOLOGY AND PRINCIPAL FINDINGS: We showed CT scans from patients with acute ischaemic stroke (n = 32, with different patient characteristics and ischaemia signs to doctors in stroke-related specialties world-wide over the web. CT scans were shown twice, randomly and blindly. Observers entered their scan readings, including early ischaemic signs by three scoring methods, into the web database. We compared observers' scorings to a reference standard neuroradiologist using area under receiver operator characteristic curve (AUC analysis, Cronbach's alpha and logistic regression to determine the effect of scales, patient, scan and observer variables on detection of early ischaemic changes. Amongst 258 readers representing 33 nationalities and six specialties, the AUCs comparing readers with the reference standard detection of ischaemic signs were similar for all scales and both occasions. Being a neuroradiologist, slower scan reading, more pronounced ischaemic signs and later time to CT all improved detection of early ischaemic signs and agreement on the rating scales. Scan quality, stroke severity and number of years of training did not affect agreement. CONCLUSIONS: Large-scale observer reliability studies are possible using web-based tools and inform routine practice. Slower scan reading and use of CT infarct rating scales improve detection of acute ischaemic signs and should be encouraged to improve stroke diagnosis.

  5. A Large Web-Based Observer Reliability Study of Early Ischaemic Signs on Computed Tomography. The Acute Cerebral CT Evaluation of Stroke Study (ACCESS)

    Science.gov (United States)

    Wardlaw, Joanna M.; von Kummer, Rüdiger; Farrall, Andrew J.; Chappell, Francesca M.; Hill, Michael; Perry, David

    2010-01-01

    Background Early signs of ischaemic stroke on computerised tomography (CT) scanning are subtle but CT is the most widely available diagnostic test for stroke. Scoring methods that code for the extent of brain ischaemia may improve stroke diagnosis and quantification of the impact of ischaemia. Methodology and Principal Findings We showed CT scans from patients with acute ischaemic stroke (n = 32, with different patient characteristics and ischaemia signs) to doctors in stroke-related specialties world-wide over the web. CT scans were shown twice, randomly and blindly. Observers entered their scan readings, including early ischaemic signs by three scoring methods, into the web database. We compared observers' scorings to a reference standard neuroradiologist using area under receiver operator characteristic curve (AUC) analysis, Cronbach's alpha and logistic regression to determine the effect of scales, patient, scan and observer variables on detection of early ischaemic changes. Amongst 258 readers representing 33 nationalities and six specialties, the AUCs comparing readers with the reference standard detection of ischaemic signs were similar for all scales and both occasions. Being a neuroradiologist, slower scan reading, more pronounced ischaemic signs and later time to CT all improved detection of early ischaemic signs and agreement on the rating scales. Scan quality, stroke severity and number of years of training did not affect agreement. Conclusions Large-scale observer reliability studies are possible using web-based tools and inform routine practice. Slower scan reading and use of CT infarct rating scales improve detection of acute ischaemic signs and should be encouraged to improve stroke diagnosis. PMID:21209901

  6. Iterative Reconstruction for Cardiopulmonary Computed Tomography

    NARCIS (Netherlands)

    Willemink, M.J.

    2015-01-01

    Introduction The number of computed tomography (CT) examinations has increased rapidly since CT became commercially available. This resulted in growing concerns regarding the risk of malignancies induced by application of medical ionizing radiation. Therefore, radiation dose reduction strategies ar

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  8. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  9. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  10. Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa.

    Science.gov (United States)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Kamaleshwaran, Koramadai Karuppusamy; Agrawal, Kanhaiyalal; Gupta, Ashok Kumar; Mittal, Bhagwant Rai

    2012-01-01

    Malignant otitis externa is a severe, rare infective condition of the external auditory canal and skull base. The diagnosis is generally made from a range of clinical, laboratory, and imaging findings. Technetium 99m methylene diphosphonate bone scintigraphy is known to detect osteomyelitis earlier than computed tomography. The authors present a patient with bilateral malignant otitis externa where the extent of skull base involvement was determined on 3-phase bone scintigraphy with single photon emission computed tomography/computed tomography.

  11. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  12. Brain computed tomography of the hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Park, C. K.; Cho, O. K.; Hahm, C. K. [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1980-12-15

    Now a day, hypertension is more increasing in frequency and ranked the top of the causes of death in Korea and other nations. Most of cerebrovascular accidents in hypertensive patients are composed of vascular occlusive changes and hemorrhages. In cerebral angiogram, we can only detect occlusion of large artery and large mass effect from hematoma or cerebral infarction without identification of its entity. The computed tomogram, however, is the best way for evaluation of cerebrovascular diseases including detection of nature, location, amount, and associated changes. This study includes evaluation of computed tomograms of 106 patients with hypertension during the period of 17 months from Feb. 1979 to June 1980 in the department of radiology, college of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 106 patients was broad ranging from 25 years to 76 years. 67.9% of patients were over the age of 50. The male and female sex ratio was 3:2. 2. 28 out of 106 patients were normal and 78 patients revealed abnormal on C. T. findings; those were intracranial hemorrhage (35 patients), cerebral infarction (32 patients) and brain atrophy (11 patients). 3. All of the intracranial hemorrhage except one were intracerebral hemorrhage; those were located in the cerebral hemisphere (19 patients), basal ganglia (15 patients) and brain stem (1 patient). The except one case of intracranial hemorrhage was subdural hematoma. 7 patients of intraventricular hemorrhage and 1 patient of subarachnoid hemorrhage were combined with intracerebral hemorrhage. 2/3 of patients who had hemorrhage in cerebral hemisphere revealed lesions in the parietal and temporal lobes. 4. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (20 cases), and the next was basal ganglia (11 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. The left basal ganglia was more commonly involved

  13. Proton computed tomography images with algebraic reconstruction

    Science.gov (United States)

    Bruzzi, M.; Civinini, C.; Scaringella, M.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.

    2017-02-01

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to 1% and spatial resolutions CT in hadron-therapy.

  14. 抑郁症患者局部脑血流灌注变化研究%Detection of cerebral blood flow with single emission computed tomography in depressive patients

    Institute of Scientific and Technical Information of China (English)

    余俊丽; 焦举; 许杰华; 程木华; 张峰; 张勇

    2009-01-01

    目的 分析抑郁症患者单光子发射型计算机断层显像(SPECT)局部脑血流(SCBF)灌注变化的特点,并初步探讨rCBF显像在抑郁症患者中的诊断价值. 方法 对10例正常人及临床诊断为抑郁症的32例患者分别进行SPECT局部脑血流灌注显像,利用感兴趣区(ROI)法观察rCBF情况;11例患者同期行MRI普通扫描.结果 32例抑郁症患者中31例发现rCBF显像异常,共检出71个病灶,分别位于双侧额叶、颞叶、基底节、海马、扣带回及左侧岛叶,其中57个病灶位于颞叶、海马、扣带回及岛叶,即边缘系统,9个病灶位于额叶,5个病灶位于基底节;基底节区病灶局部脑血流灌注均增高,其他部位病灶均降低;双侧大脑半球rCBF病灶构成比差异无统计学意义(χ~2=409,P=0.790).11例患者同期做MRI扫描,3例发现异常(2例轻度脑萎缩,1例海马萎缩),而此11例患者rCBF显像均发现异常.1例正常人rCBF未发现异常显像.结论 大多数抑郁症患者存在脑边缘系统rCBF降低,部分患者存在基底节区rCBF增高.SPECT能敏感地发现抑郁症患者rCBF灌注的变化,对抑郁症的诊断具有一定的价值.%Objective To analyze the changes of regional cerebral blood flow (rCBF) with SPECT in depressive patients, and explore the diagnosis value of rCBF imaging for depression. Methods The rCBF imaging was detected by single emission computed tomography (SPECT) on 32 depressive patients and 10 normal subjects, and the characteristics of rCBF changes were assessed with a region-of-interest (ROI) technique. Normal MRI scans were conducted on 11 patients at the same stage. Results Abnormal rCBF was showed in 31 patients with 71 focuses that were located in the bilateral frontal lobe (9), the basal ganglia (5) and the limbic system (57), including the temporal lobe, the hippocampus, the cingulated gyms and the left insular cortex. All abnormalities presented a decreased rCBF except the basal ganglia. No

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  16. Computed tomography of intracranial tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Lan; Lee, Jung Suk; Eun, Chung Kie; Kim, Soon Yong [School of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1981-09-15

    CT is a valuable method in determining number, location and extent of lesions, although a definite diagnosis is often not possible on CT. In intracranial tuberculosis, CT was helpful in the diagnosis, assessing the degree of hydrocephalus and evaluating the effectiveness of antituberculous therapy. Twenty-one cases of clinically proven intracranial tuberculosis were studied by CT in our hospital during last 3 years. Of them, eighteen cases were tuberculous meningitis and the rests were tuberculoma. The results were as follows: 1. Tuberculous meningitis presented the following three patterns of CT findings according to its disease process. a. In early stage of the disease, suspicious multiple isodense small nodules in the cerebral and cerebellar hemispheres showed dense enhancement in postcontrast scan representing miliary tubercles. b. In later stage of the disease, precontrast scan showed partial or total obliteration of the basal and sylvian cisterns with mild dilatation of ventricular system. Postcontrast scan showed dense enhancement of basal and sylvian cisterns. This type of finding was the most common in our series. c. Moderate to marked dilatation of ventricle with or without a cluster of calcifications in suprsella area on precontrast scan was seen in far later stage of as a sequellae of the disease. No enhancement was noted in postcontrast study. 2. Tuberculoma showed an isodense or slightly hyperdense area in the cerebral or cerebellar hemisphere with associated minimal edema in precontrast study. Postcontrast scan showed a small ring enhancement with central lucent area.

  17. Computational analysis of cerebral cortex

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Abe, Osamu; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine, Tokyo (Japan)

    2010-08-15

    Magnetic resonance imaging (MRI) has been used in many in vivo anatomical studies of the brain. Computational neuroanatomy is an expanding field of research, and a number of automated, unbiased, objective techniques have been developed to characterize structural changes in the brain using structural MRI without the need for time-consuming manual measurements. Voxel-based morphometry is one of the most widely used automated techniques to examine patterns of brain changes. Cortical thickness analysis is also becoming increasingly used as a tool for the study of cortical anatomy. Both techniques can be relatively easily used with freely available software packages. MRI data quality is important in order for the processed data to be accurate. In this review, we describe MRI data acquisition and preprocessing for morphometric analysis of the brain and present a brief summary of voxel-based morphometry and cortical thickness analysis. (orig.)

  18. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E; Haase, Robert; Laule, Michael

    2017-01-01

    OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninva...... angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low...

  19. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  2. Computed tomography demonstration of cholecystogastric fistula

    Directory of Open Access Journals (Sweden)

    Chung Kuao Chou, MD, MPH

    2016-06-01

    Full Text Available Cholecystogastric fistula is a rare complication of chronic cholecystitis or long-standing cholelithiasis. It results from the gradual erosion of the approximated, chronically inflamed wall of the gall bladder and stomach with fistulous tract formation. The present case describes the direct visualization of a cholecystogastric fistula by computed tomography in a patient without prior biliary system complaints.

  3. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  4. Cervical diplomyelia revealed by computed tomography (CT)

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, G.B.; Davidovits, P.; Cerisoli, M.; Giulioni, M.

    1982-05-01

    An unusual case of cervical diplomyelia diagnosed by Computed Tomography (CT) is reported. The usefulness of CT examination in the evaluation of spinal dysraphic defects is emphasized, though performed without CSF enhancement. Visualisation of spinal cord splitting in the absence of bony spicula allows the authors to differentiate between diplomyelia and diastematomyelia which have been often described by using both terms interchangeably.

  5. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  6. Computed tomographic findings of cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Nak Kwan; Nam, Kyung Jin; Park, Churl Min; Eun, Chung Kie; Lee, Sun Wha [Kyung Hee Unversity Hospital, Seoul (Korea, Republic of)

    1983-03-15

    Paragonimiasis is widely distributed in Far East and Southeast Asia, particularly in Korea. The central nervous system is the most frequent location for paragonimiasis outside the lungs. We analyzed the computed tomographic findings of 17 cases which were diagnosed pathologically and clinically as cerebral paragonimiasis. The results were as follows: 1. The ratio of male to female was 10 : 7 and about 88% of cases were under the age of 40 years. 2. The common locations of cerebral paragonimiasis were the occipital (12 cases) and temporal (11 cases) lobes. 3. Precontrast CT findings of cerebral paragonimiasis were low density with calcifications in 6 cases, low and isodensities in 4 cases, mixed densities in 3 cases, only low density in 2 cases and only calcification in 2 cases. Hydrocephalus (7 cases), mass effect (6 cases), atrophic change (6 cases) and cyst formation (3 cases) were associated. 4. The shape of calcifications in CT scan were soap-bubble or ring in 6 cases, nodular or oval in 6 cases, stipple in 4 cases and amorphous conglomerated in 2 cases. 5. The contrast -enhanced 8 cases were 5 ring or rim like, 2 nodular and 1 irregular enhancements, while 9 cases were not enhanced.

  7. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  8. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  9. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  10. Trip report: Marshall Space Center computed tomography

    Science.gov (United States)

    Harbour, J. R.; Andrews, M. K.

    BIR Inc. is a small company out of the Chicago area which sells equipment for producing images by tomography. They have built a relatively large instrument, called ACTIS, for NASA at the Marshall Space Center in Huntsville, Alabama and still gave access to this instrument. BIR has a grant from the Department of Energy (DOE) to determine the utility of computed tomography (CT) for characterization of nuclear and hazardous waste within the DOE complex. As part of this effort, the potential of this technique for obtaining images of canistered waste forms has been investigated. Funding for data acquisition was provided through this grant.

  11. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  12. Computed tomography of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Haughton, V.M.; Williams, A.L.

    1982-01-01

    The book describes the computed tomographic (CT) techniques for imaging the different elements comprising the spinal column and canal. The use of intravenous and intrathecal contrast enhancement and of xenon enhancement is briefly mentioned. Reconstruction techniques and special problems regarding CT of the spine are presented. CT of the spinal cord, meninges and subarachnoid space, epidural space, intervertebral discs, facet joints, and vertebrae present normal anatomy, and several common pathologic conditions. (KRM)

  13. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  14. Computed tomography in mitochondrial cytopathy

    Energy Technology Data Exchange (ETDEWEB)

    Egger, J.; Kendall, B.E.

    1981-10-01

    The clinical and computed tomographic (CT) findings in 11 proven cases of mitochondrial cytopathy (mitochondrial myopathy, Kearns Sayre syndrome, ophthalmoplegia plus) were studied. The CT changes included focal low density lesions in the basal ganglia and white matter and atrophy which could be slight or diffuse and severe. Calcification has been described in the basal ganglia, but did not occur in our series. Serial CT showed progression of the abnormalities. The differential diagnosis is discussed.

  15. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  16. [Analysis of single-photon emission computed tomography in patients with hypertensive encephalopathy complicated with previous hypertensive crisis].

    Science.gov (United States)

    Kustkova, H S

    2012-01-01

    In cerebrovascular diseases pefuzionnaya single photon emission computed tomography with lipophilic amines used for the diagnosis of functional disorders of cerebral blood flow. Quantitative calculations helps clarify the nature of vascular disease and clarify the adequacy and effectiveness of the treatment. In this modern program for SPECT ensure conduct not only as to the calculation of blood flow, but also make it possible to compute also the absolute values of cerebral blood flow.

  17. Cone beam computed tomography in endodontics.

    Science.gov (United States)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillo-facial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice.

  18. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  19. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  20. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    -CCTR, showed that coronary CT angiographies accounted for only 23% of all nonregistered cardiac CTs, indicating >90% completeness of coronary CT angiographies in the WDHR-CCTR. The completeness of individual variables varied substantially (range: 0%-100%), but was >85% for more than 70% of all variables. Using......BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... expected numbers; and 4) positive predictive values as well as negative predictive values of 19 main patient and procedure variables. RESULTS: By December 31, 2012, almost 22,000 cardiac CTs with up to 40 variables for each procedure have been registered. Of these, 87% were coronary CT angiography...

  1. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  2. Cone beam computed tomography use in orthodontics.

    Science.gov (United States)

    Nervina, J M

    2012-03-01

    Cone beam computed tomography (CBCT) is widely used by orthodontists to obtain three-dimensional (3-D) images of their patients. This is of value as malocclusion results from discrepancies in three planes of space. This review tracks the use of CBCT in orthodontics, from its validation as an accurate and reliable tool, to its use in diagnosing and treatment planning, and in assessing treatment outcomes in orthodontics.

  3. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  4. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  5. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  6. Computed tomography and obstructive biliary disease.

    Science.gov (United States)

    Havrilla, T R; Haaga, J R; Alfidi, R J; Reich, N E

    1977-05-01

    Forty-four patients with confirmed biliary diseases were studied to determine the value of computed tomography (CT) in the diagnosis of biliary pathology. The results indicate that CT is useful and highly accurate in differentiating between obstructive (surgical) and nonobstructive (medical) disease entities. Of the cases with proved obstruction, 88% were correctly identified. All of the nonobstructive cases had positive CT correlation. In addition, the underlying cause of the occlusion was determined in the majority of cases.

  7. Cone Beam Computed Tomography - Know its Secrets

    OpenAIRE

    Kumar, Mohan; Shanavas, Muhammad; Sidappa, Ashwin; Kiran, Madhu

    2015-01-01

    Cone-beam computed tomography (CBCT) is an advanced imaging modality that has high clinical applications in the field of dentistry. CBCT proved to be a successful investigative modality that has been used for dental and maxillofacial imaging. Radiation exposure dose from CBCT is 10 times less than from conventional CT scans during maxillofacial exposure. Furthermore, CBCT is highly accurate and can provide a three-dimensional volumetric data in axial, sagittal and coronal planes. This article...

  8. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  9. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  10. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice.

  11. The diagnostic contribution of computed tomography in intranasal carcinoma with retrobulbar, oral and brain invasion in a canine: case report; Contribuicao da tomografia computadorizada no diagnostico de carcinoma intranasal com invasao retrobular, oral e cerebral em canino: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Zardo, Karen Maciel, E-mail: kmz@bol.com.br; Belotta, Alexandra Frey; Babicsak, Viviam Rocco; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria; Zanoni, Diogo Souza; Costa, Denis Carvalho [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Veterinaria

    2012-07-01

    Intranasal tumors are uncommon and in most cases are malignant, aggressive and with low to moderate potential for metastasis. Clinical signs are usually caused by progressive obstruction of the upper airways. The test cytopathological also is a diagnosis method, but the definitive diagnosis is made by histopathological. Computed tomography (CT) is recommended to treatment planning. A poodle was attended at the veterinary hospital with a clinical history of epistaxis and nasal and ocular secretions, seizures and severe dyspnoea. The animal underwent to radiographic examination of the chest and skull as well as helical computed tomography of the nasal cavity and brain before and after the administration of intravenous contrast. The CT findings revealed an expansive bilateral nasal cavity neoformation, with involvement of the retrobulbar space, right frontal sinus, brain and oral cavity, suggesting a neoplastic or an infectious process. The CT examination allowed the material collection, directly from the mass, to cytological examination, providing the diagnosis of carcinoma. CT also allowed the determination of the unfavorable prognosis of the patient and the treatment planning which not included the surgical excision of the neoformation. Although CT was not conclusive in the diagnosis of carcinoma, it was essential to accurately define the extent of the lesion, to guide the collection of material directly from the tumor and to determine the prognosis of the animal, proving to be an extremely useful tool in cases of tumors intranasal in dogs. (author)

  12. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  13. Cranial computerized tomography and cerebral angiography in diagnosis of infarction

    Energy Technology Data Exchange (ETDEWEB)

    Zuelich, K.J.

    1988-08-05

    Discussion of the radiological means to further analysis of the pathogenesis of cerebrovascular alterations up to real stroke with infarction. Today in the first place computer-tomography even with contrast means, moreover in the form of 'angio-CT' are used. Localization, size, form, and the grade of tissue destruction may be analyzed. Furthermore perifocal edema and the stage as also the effect of vascular anastomoses for a collateral circulation may be evaluated. Invasive angiography with puncture of carotid and vertebral arteries is used only in special rare indications. Instead, digital computerized angiography (DSA) can be adopted if particular interest is in the study of intracranial arteries, even with an 'invasive' approach, e.g. by femoral catheter (Seldinger). In summarizing: For the analysis of particular problems radiological methods may assist diagnosis and therapy of cerebrovascular infarct.

  14. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  15. Computed tomographic findings of cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Weon Tae; Jung, Min Ki; Kang, Heoung Keun; Chung, Hyon De [Chonnam University Medicine School, Gwangju (Korea, Republic of)

    1988-10-15

    Authors analyzed the computed tomographic (CT) findings of 19 cases pathologically and clinically proven cerebral paragonimiasis that were performed at Chonnam University Hospital from April 1983 through March 1987. The results were as follows: 1. Male to female ratio was 15:4 and the most prevalent age group was 3rd decade (7 cases). The common symptoms were epileptic seizure (16 cases) and headache (12 cases). 2. The multiplicity of cerebral paragonimiasis was 7 of 19 cases and the distributions of lesion were occipital (11 cases), temporal (6 cases), frontal (5 cases) and parietal (5 cases) lobe. 3. The calcification on CT scan were single (7 cases) or multiple (7 cases) and the shape of calcification were nodular (10 cases), soap babble of ring (8 cases), and stippled (6 cases). The pattern of contrast enhancement were ring (5 cases) or nodular (1 case), and along the basal cistern (1 case with arachnoiditis). 4. 12 out of 13 cases, had long clinical symptoms over 3 years with calcifications, could be analyzed according to Valentine's vascular territory; 6 cases in PCA territory, 3 in MCA and 3 in ACA. 5. CT findings were noted according to the duration of symptoms; 5 cases, had symptoms less than 1 year, showed abscess (5 cases) and arachnoiditis (1 case) with brain edema, mass effect, hydrocephalus and contrast enhancement but no calcification in all. One case, had symptom of 1 year and 2 months, showed partially calcified granulomatous lesion with perifocal edema and contrast enhancement, 13 cases, had symptoms over 3 years, showed multiple calcification with brain atrophy (10 cases), but no contrast enhancement in all cases.

  16. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  17. Cerebral blood flow and metabolism for Broca's aphasia using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Toshiaki

    1987-12-01

    A total of 11 patients with Broca's aphasia (BA) underwent positron emission tomography (PET) with the purpose of investigating the responsible region and the symptomatic flow and metabolism thresholds for BA. Computed tomography (CT) was concurrently performed. In the group of 3 patients undergoing PET with C-11 glucose, both PET and CT provided abnormal findings in the region that is thought to be responsible for BA (Broca's area), including the cortex and subcortex in the anterior region to Sylvian fissure. The Broca's area in the remaining one was shown as low C-11 accumulation area on PET and as isodensity on CT. The second group, consisting of 8 BA patients and 30 control patients without BA, underwent PET using O-15 steady method. PET showed reduction of regional cerebral blood flow (rCBF) and oxygen metabolic rate (rCMRO/sub 2/) in the Broca's area in all BA patients. Computed tomography showed abnormal low density in the Broca's area in 3 patients, and abnormal findings in the basal ganglionic region and subcortex without evidence for abnormal low density in the Broca's area in the other 5 patients. Comparison of rCBF and rCMRO/sub 2/ in BA patients with those in control patients may show the symptomatic thresholds to be 20 - 27 ml100 gmin for rCBF and 2.0 ml100 gmin for rCMRO/sub 2/. (Namekawa, K.).

  18. White matter of the cerebellum demonstrated by computed tomography: normal anatomy and physical principles.

    Science.gov (United States)

    Maravilla, K R; Pastel, M S; Kirkpatrick, J B

    1978-04-01

    Although computed tomography (CT) delineation of normal white matter of the cerebral hemispheres has been well documented, there has been no description of white matter within the cerebellum. Through the use of phantom studies, CT number correlations between cerebellum and cerebral hemispheres, and anatomic correlation with in vitro specimens, the ability to visualize cerebellar white matter is demonstrated. Thin sections decrease volume averaging and enable consistent imaging of these structures. Size and shape of the corpus medullaris on CT scan may vary with the scan angle and level of section. Representative examples of various normal appearances are illustrated.

  19. Tomography and spectroscopy as quantum computations

    CERN Document Server

    Miquel, C; Saraceno, M; Knill, E H; Laflamme, R; Negrevergne, C; Miquel, Cesar; Paz, Juan Pablo; Saraceno, Marcos; Knill, Emmanuel; Laflamme, Raymond; Negrevergne, Camille

    2001-01-01

    Determining the state of a system and measuring properties of its evolution are two of the most important tasks a physicist faces. For the first purpose one can use tomography, a method that after subjecting the system to a number of experiments determines all independent elements of the density matrix. For the second task, one can resort to spectroscopy, a set of techniques used to determine the spectrum of eigenvalues of the evolution operator. In this letter, we show that tomography and spectroscopy can be naturally interpreted as dual forms of quantum computation. We show how to adapt the simplest case of the well-known phase estimation quantum algorithm to perform both tasks, giving it a natural interpretation as a simulated scattering experiment. We show how this algorithm can be used to implement an interesting form of tomography by performing a direct measurement of the Wigner function of a quantum system. We present results of such measurements performed on a system of three qubits using liquid state...

  20. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  1. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...

  2. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  3. SADMFR guidelines for the use of cone-beam computed tomography/ Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Bornstein, Michael M.; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J. Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C.

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the ...

  4. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  5. Computed tomography in pelvic and acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Born, H.; Schmidt, C.

    1988-06-01

    In a retrospective study we analyzed the results of 127 patients, who were examined not only by means of conventional radiography but also by means of computed tomography after a trauma of the pelvic. Our investigations were based upon such patients, to whom a definite diagnostic procedure of plain radiography had been performed. Therefore all polytraumatized patients were inapplicable. They were only examined by computed tomography because of other more important accompanying injuries of other body regions. We compared the results of 127 patients with pelvic trauma. The results of the CT were in accordance with the results of the plain radiography for 103 patients. The results of the CT concerning the availability and the localization of the fractures were basically coincident with the plain radiography for 22 patients, but the CT showed a higher degree of trauma and additional intraarticular fragments. Two isolated lesions of the sacroiliac joint could not be recognized by both methods. They could only be diagnosed by bone scintigraphy on the third day after trauma.

  6. Computed Tomography Technology: Development and Applications for Defence

    Science.gov (United States)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-09-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT&E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  7. Use of high-resolution computed tomography and positron emission tomography/computed tomography in the management of stage IA adenocarcinoma.

    Science.gov (United States)

    Miyata, Yoshihiro; Tsutani, Yasuhiro; Okada, Morihito

    2012-01-01

    Preoperative determination of malignant behavior is critical in choosing suitable therapeutic strategies such as sublobar resection for patients with small lung cancers. The aim of present review was to evaluate high-resolution computed tomography and fluorodeoxyglucose-positron emission tomography/computed tomography as tools for management of clinical stage IA adenocarcinoma.

  8. Statistical parametric mapping in brain single photon computed emission tomography after carbon monoxide intoxication.

    Science.gov (United States)

    Watanabe, N; Nohara, S; Matsuda, H; Sumiya, H; Noguchi, K; Shimizu, M; Tsuji, S; Kinuya, S; Shuke, N; Yokoyama, K; Seto, H

    2002-04-01

    The purpose of this retrospective study was to assess regional cerebral blood flow in patients after carbon monoxide intoxication by using brain single photon emission computed tomography and statistical parametric mapping. Eight patients with delayed neuropsychiatric sequelae and ten patients with no neuropsychiatric symptoms after carbon monoxide intoxication were studied with brain single photon emission tomography imaging with 99mTc-hexamethyl-propyleneamine oxime. Forty-four control subjects were also studied. We used the adjusted regional cerebral blood flow images in relative flow distribution (normalization of global cerebral blood flow for each subject to 50 ml x 100 g(-1) x min(-1) with proportional scaling) to compare these groups with statistical parametric mapping. Using this technique, significantly decreased regional cerebral blood flow was noted extensively in the bilateral frontal lobes as well as the bilateral insula and a part of the right temporal lobe in the patients with delayed neuropsychiatric sequelae as compared with normal volunteers (Pparametric mapping is a useful technique for highlighting differences in regional cerebral blood flow in patients following carbon monoxide intoxication as compared with normal volunteers. The selectively reduced blood flow noted in this investigation supports the contention that the decrease following carbon monoxide intoxication may be prolonged and further worsen in the frontal lobe. In addition, the present study may help to clarify the characteristics of the pathophysiological alteration underlying delayed neuropsychiatric sequelae.

  9. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  10. Reconstructing cetacean brain evolution using computed tomography.

    Science.gov (United States)

    Marino, Lori; Uhen, Mark D; Pyenson, Nicholas D; Frohlich, Bruno

    2003-05-01

    Until recently, there have been relatively few studies of brain mass and morphology in fossil cetaceans (dolphins, whales, and porpoises) because of difficulty accessing the matrix that fills the endocranial cavity of fossil cetacean skulls. As a result, our knowledge about cetacean brain evolution has been quite limited. By applying the noninvasive technique of computed tomography (CT) to visualize, measure, and reconstruct the endocranial morphology of fossil cetacean skulls, we can gain vastly more information at an unprecedented rate about cetacean brain evolution. Here, we discuss our method and demonstrate it with several examples from our fossil cetacean database. This approach will provide new insights into the little-known evolutionary history of cetacean brain evolution.

  11. Computed tomography in metastatic renal cell carcinoma.

    Science.gov (United States)

    Griffin, Nyree; Grant, Lee Alexander; Bharwani, Nishat; Sohaib, S Aslam

    2009-08-01

    Recent developments in chemotherapy have resulted in several new drug treatments for metastatic renal cell carcinoma (RCC). These therapies have shown improved progression-free survival and are applicable to many more patients than the conventional cytokine-based treatments for metastatic RCC. Consequently imaging is playing a greater part in the management of such patients. Computed tomography (CT) remains the primary imaging modality with other imaging modalities playing a supplementary role. CT is used in the diagnosis and staging of metastatic RCC. It is used in the follow-up of patients after nephrectomy, in assessing the extent of metastatic disease, and in evaluating response to treatment. This review looks at the role of CT in patients with metastatic RCC and describes the appearances of metastatic RCC before and following systemic therapy.

  12. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  13. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...... have become the standard with which to assess emphysema extent but airway abnormalities have so far been more challenging to quantify. Automated methods for analysis are indispensable as the visible airway tree in a CT scan can include several hundreds of individual branches. However, automation...... of scan on airway dimensions in subjects with and without COPD. The results show measured airway dimensions to be affected by differences in the level of inspiration and this dependency is again influenced by COPD. Inspiration level should therefore be accounted for when measuring airways, and airway...

  14. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...... concerns measurements of each single carcass, to improve the raw material utilisation by individually adapted processing. Measurements performed online in the abattoir demand fast, robust and cost-effective imaging. We propose a tomographic reconstruction algorithm, enabling a substantial reduction...... of the subject-specific X-ray data needed to produce high quality images for accurate measurements. This is very beneficial for the abattoirs, as a reduction in acquired data translates directly into higher speed and a lower cost. The thesis demonstrates the great potential of CT as a technology for improving...

  15. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    on the market today based on different perfusion algorithms. However, there is no consensus on which protocol and algorithm to use for specific organs. In this article, the authors give an introduction to CT perfusion in abdominal imaging introducing technical aspects for calculation of perfusion parameters......Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...

  16. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  17. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  18. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  19. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...... influence from the surrounding wall thickness on the measurement of roundness was documented for the metal item. The comparison shows that CT scanning on small industrial parts, generally speaking, is connected with uncertainties in the range 8-53 μm, as compared to an uncertainty range of 1.5-5.5 μm using...

  20. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  1. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on t

  2. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  3. Computed tomography in traumatic defects of the diaphragm.

    Science.gov (United States)

    Demos, T C; Solomon, C; Posniak, H V; Flisak, M J

    1989-03-01

    Two patients with traumatic diaphragmatic defects visible on computed tomography are presented. The diagnosis was delayed for several years in both patients. The diagnosis of these acquired diaphragmatic defects is often difficult. Computed tomography can lead to earlier diagnosis by demonstrating the defect in some patients when radiographic studies are not diagnostic.

  4. Intravenous coronary angiography using electron beam computed tomography

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A H; van Geuns, R J; van Ooijen, P M; Oudkerk, M; de Feyter, P J

    1999-01-01

    Intravenous coronary angiography with electron beam computed tomography (EBCT) allows for the noninvasive visualisation of coronary arteries. With dedicated computer hardware and software, three-dimensional renderings of the coronary arteries, veins, and other cardiac structures can be constructed f

  5. Embolic intracranial arterial occlusion visualized by non-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Masaaki; Minematsu, Kazuo; Choki, Junichiro; Yamaguchi, Takenori (National Cardiovascular Center, Suita, Osaka (Japan))

    1984-12-01

    A 77-year-old woman with a history of valvular heart disease, atrial fibrillation and a massive infarction in the right cerebral hemisphere developed contralateral infarction due to occlusion of the internal carotid artery. A string-like structure with higher density than normal brain was demonstrated on non-enhanced computed tomography that was performed in the acute stage. This abnormal structure seen in the left hemisphere was thought to be consistent with the middle cerebral artery trunk of the affected side. Seventeen days after the onset, the abnormal structure was no more visualized on non-enhanced CT. These findings suggested that the abnormal structure with increased density was compatible with thromboembolus or intraluminal clot formed in the distal part of the occluded internal carotid artery. The importance of this finding as a diagnostic sign of the cerebral arterial occlusion was discussed.

  6. Computed tomography in suppurative meningitis. CT and clinical findings in the acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Akira; Fujiwara, Katsuhiko; Iino, Shigeru (Kyoto Prefectural Univ. of Medicine (Japan))

    1982-06-01

    Computed tomography abnormalities revealed in 18 of 29 patients (62%) with infantile supprative meningitis. The abnormalities included ventricular dilatation (12 cases), subdural edema (8), cerebral infarction (4), cerebral atrophy (3), encephalitis (2), and cerebral herniation (1). The comparative study of CT pictures and clinical findings in the acute stage of the disease showed that the high incidence of these abnormalities occurred in the following conditions: 1) The age was less than 1 year, 2) establishment of the diagnosis took more than 5 days, 3) glucose of the cerebrospinal fluid was less than 200 mg/dl, 4) protein of the cerebrospinal fluid was more than 200 mg/dl, and 5) convulsion occurred 24 hrs after institution of the treatment.

  7. Intraoperative Perfusion Computed Tomography in Carotid Endarterectomy: Initial Experience in 16 Cases

    Science.gov (United States)

    Xue, Zhe; Peng, Dingwei; Sun, Zhenghui; Wu, Chen; Xu, Bainan; Wang, Fuyu; Zhou, Dingbiao; Dong, Tianxiang

    2016-01-01

    Background This study aimed to evaluate the changes in perfusion computed tomography (PCT) parameters in carotid endarterectomy (CEA), and to discuss the use of intraoperative PCT in CEA. Material/Methods Sixteen patients with carotid stenosis who also underwent CEA with intraoperative CT were recruited in this study. We calculated quantitative data on cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), and the relative parameter values, including relative CBF (rCBF), relative CBV (rCBV), and relative TTP (rTTP). The role of PCT was assessed and compared to conventional monitoring methods. Results There were no significant differences in any of the parameters in the anterior cerebral artery (ACA) territory (P>0.05). In the middle cerebral artery (MCA) territory, the CBF and CBV increased and TTP decreased in the operated side during CEA; the rCBF and rCBV increased and the rTTP decreased significantly (P<0.05). In 16 patients, CT parameters were improved, SSEP was normal, and MDU was abnormal. In 3 patients, CBF increased by more than 70% during CEA. Relative PCT parameters are sensitive indicators for detecting early cerebral hemodynamic changes during CEA. Cerebral hemodynamics changed significantly in the MCA territory during CEA. Conclusions Intraoperative PCT could be an important adjuvant monitoring method in CEA. PMID:27657307

  8. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-09-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients.

  9. Regional cerebral blood flow in acute stage with ischemic cerebrovascular disease by xenon-133 inhalation and single photon emission computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, Hiroyuki; Iino, Katsuro; Kojima, Hisashi; Saito, Hitoshi; Suzuki, Mikio; Watanabe, Kazuo; Kato, Toshiro

    1987-05-01

    Single photon emission computed tomography (SPECT) with xenon-133 inhalation method was undertaken within 48 hr after the onset in 68 patients with ischemic cerebrovascular disease. The results for regional cerebral blood flow (rCBF) were compared with concurrently available computed tomography (CT) scans. In patients with cerebral infarction, SPECT detected ischemic lesions earlier than CT, with the detectability being 92 %. The area with a decreased blood flow, as seen on SPECT, was more extensive than the low density area on CT, with a concomitant decrease in blood flow in the contralateral cerebral hemisphere. Crossed cerebellar diaschisis was associated with stenosis of the internal carotid artery in 50 % (7/14), and with stenosis of the middle cerebral artery in 35 % (9/26). Abnormal SPECT findings were seen in 47 % (8/17) of the patients with transient ischemic attack (TIA). Five TIA patients had a decreased rCBF on SPECT, which was not provided by CT scans. On the contrary, small infarct lesions in the cerebral basal ganglia, as observed in 4 patients, was not detected by SPECT, but detected by CT. This may imply the limitations of SPECT in the detection of deep-seated lesions of the cerebrum. The results led to the conclusion that SPECT can be performed safely even in acute, seriously ill patients to know changes in rCBF because it is noninvasive and is capable of being repeated in a short time. (Namekawa, K.).

  10. [Study of regional cerebral glucose metabolism, in man, while awake or asleep, by positron emission tomography].

    Science.gov (United States)

    Franck, G; Salmon, E; Poirrier, R; Sadzot, B; Franco, G

    1987-03-01

    Measurements of regional cerebral glucose uptake by the 18F-fluorodeoxyglucose technique (18FDG) and positron emission tomography (PET) along with polygraph recordings were made serially during relaxed wakefulness and different stages of nocturnal sleep in two right-handed normal volunteers. During stage III-IV sleep, values declined diffusely in both hemispheric regions (-31%), thalamus (-33%), cerebellum (-33%) and brain stem (-25%). During paradoxical sleep regional values increased diffusely compared with slow wave sleep. Compared to wakefulness, regional metabolic values seemed to increase but the results were more variable from one volunteer to the other. These preliminary data indicate important regional alterations in cerebral metabolism between sleep states.

  11. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  12. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  13. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  14. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  15. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  16. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  17. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  18. Micro computed tomography for vascular exploration

    Directory of Open Access Journals (Sweden)

    Zhuang Zhen W

    2010-03-01

    Full Text Available Abstract Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validation, and visualization of results. The usefulness of micro-CT, however, can be adversely affected by a range of factors including physical animal preparation, numerical quantification, visualization of results, and quantification software with limited possibilities. Exacerbating these inherent difficulties is the lack of a unified standard for micro-CT imaging. Most micro-CT today is aimed at particular applications and the software tools needed for quantification, developed mainly by imaging hardware manufacturers, lack the level of detail needed to address more specific aims. This review highlights the capabilities of micro-CT for vascular exploration, describes the current state of imaging protocols, and offers guidelines and suggestions aimed at making micro-CT more accurate, replicable, and robust.

  19. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  20. Application of computed tomography to spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sha, N.; Kurihara, A.; Kataoka, O. (Kobe Univ. (Japan). School of Medicine)

    1980-08-01

    The axial tomographic examination of the spine and its soft tissues is now readily available for orthopaedic surgery. If the appropriate conditions are maintained, computed tomography (CT) can provide useful information concerning the diagnosis and the treatment of spinal diseases. There are, however, some pitfalls in interpreting CT scans: 1) the existence of the lesion may be masked, and 2) its extent and configuration may be over- or under-evaluated depending on such technical factors as the slicing level, the slicing angle, the window width, and the window level. Experimental studies were carried out on a plaster of Paris model of the spine and a cadaver spine to determine the appropriate technical factors by which the CT (EMI whole body CT scanner 5005) can be applied accurately to a diseased spine. The factors obtained were then applied in examining ninety-nine patients with various spinal disorders. Window levels ranging between 100 and 150 were found to be most appropriate. The slicing angle should be 90/sup 0/, or perpendicular to the long axis of the object under study. However, deviations of +10 or -10 degrees are acceptable. The CT view of the spine may be divided into two patterns at the cervical and thoracic levels and into three patterns at the lumbar level. In addition, the usefulness and the diagnostic value of CT for various spinal problems are discussed based on our clinical material.

  1. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  2. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  3. Computer tomography-aided ventriculography and cisternography

    Energy Technology Data Exchange (ETDEWEB)

    Cernoch, Z.; Sercl, M.; Heger, L.; Parizek, J. (Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta)

    1983-01-28

    Computer tomography was used in 42 patients for the exploration of ventricular and subarachnoidal spaces following intraventricular, lumbar or suboccipital injections of 3 to 5 ml Amipaque using the kind of manoeuvre to permit optimum filling of the region concerned. This type of CT ventriculo- or cisternography is a significant supplement to plain CT examination particularly because it supplies data on the causes of CSF passage blocks. Thus, in two female patients it proved possible to localize cysts in the 3rd ventricle, the density of which was no different from that of CSF. As regards benign stenoses of the aqueduct, it is likely to yield less information than conventional specific ventriculography. On the other hand, the technique gives perfect visualization of all possible communications between pathological intracranial cavities and the ventricular system. CT cisternography proved useful for the identification of small-size isodense growths in the region of the sella turcica, and brought convincing evidence of the causes of profuse liquorrhea by demonstrating the presence of nasal meningocele. It was also found helpful in the analysis of the craniocervical region, otherwise difficult to survey.

  4. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  5. Functional assessment of cerebral artery stenosis: A pilot study based on computational fluid dynamics.

    Science.gov (United States)

    Liu, Jia; Yan, Zhengzheng; Pu, Yuehua; Shiu, Wen-Shin; Wu, Jianhuang; Chen, Rongliang; Leng, Xinyi; Qin, Haiqiang; Liu, Xin; Jia, Baixue; Song, Ligang; Wang, Yilong; Miao, Zhongrong; Wang, Yongjun; Liu, Liping; Cai, Xiao-Chuan

    2016-10-04

    The fractional pressure ratio is introduced to quantitatively assess the hemodynamic significance of severe intracranial stenosis. A computational fluid dynamics-based method is proposed to non-invasively compute the FPRCFD and compared against fractional pressure ratio measured by an invasive technique. Eleven patients with severe intracranial stenosis considered for endovascular intervention were recruited and an invasive procedure was performed to measure the distal and the aortic pressure (Pd and Pa). The fractional pressure ratio was calculated as [Formula: see text] The computed tomography angiography was used to reconstruct three-dimensional (3D) arteries for each patient. Cerebral hemodynamics was then computed for the arteries using a mathematical model governed by Navier-Stokes equations and with the outflow conditions imposed by a model of distal resistance and compliance. The non-invasive [Formula: see text], [Formula: see text], and FPRCFD were then obtained from the computational fluid dynamics calculation using a 16-core parallel computer. The invasive and non-invasive parameters were tested by statistical analysis. For this group of patients, the computational fluid dynamics method achieved comparable results with the invasive measurements. The fractional pressure ratio and FPRCFD are very close and highly correlated, but not linearly proportional, with the percentage of stenosis. The proposed computational fluid dynamics method can potentially be useful in assessing the functional alteration of cerebral stenosis.

  6. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  7. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  8. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  9. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    2005-01-01

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic mo

  10. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  11. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  12. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  13. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hiromitsu Ohta

    2016-01-01

    Full Text Available Cerebral and cerebellar symptoms are frequently associated with Legionnaires’ disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT or magnetic resonance imaging (MRI. We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires’ disease.

  14. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques...

  15. Multi-slice Spiral Computed Tomography Manifestations of Brain and Cerebral Hemodynamics in Chronic Mountain Sickness%慢性高原病脑部MSCT表现与血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    王铎尧; 鲍海华; 赵希鹏; 李文方

    2011-01-01

    目的 观察慢性高原病(chronic mountain sickness,CMS)患者脑部多层螺旋CT(MSCT)改变.方法 研究对象共27例,其中12例为临床确诊的CMS,其余15例为正常健康志愿者.采用Philips Brilliance 16层螺旋CT对27例研究对象行脑部CT平扫加灌注扫描.结果 (1) CMS患者8例CT平扫表现为脑肿胀,脑沟裂变浅,脑室系统变小.12例患者颅内血管密度均有不同程度的增高,尤其以上矢状窦和大脑中动脉为著.通过测量分析上矢状窦CT值和双侧大脑中动脉CT值与血红蛋白(Hb)含量分析,CMS组上矢状窦CT值和双侧大脑中动脉CT值高于正常组 ( t=4.551,P<0.01和t=2.898,P<0.01 ).CMS组Hb含量与上矢状窦及大脑中动脉血管密度CT值均呈正相关(r=0.758,P<0.01 及r=0.740,P<0.01).(2) CMS患者脑灰质脑血流量(CBF)值较正常对照组减小,P<0.01,并且TTP和MTT明显延长,P<0.05和P<0.01;脑白质MTT值明显延长,P<0.01.结论 MSCT对研究CMS脑部形态学和血液动力学方面均具有重要意义.%Objective To obscrve MSCT appearances of brain in chronic mountain sickness(CMS). Methods 27 subjects were collected involved in this study , including 12 patients with CMS and 15 normal adults as control. Plain CT scan and perfusion CT imaging were performed in all subjects. Cerebral blood flow (CBF) , cerebral blood volume ( CBV) , time to pcak enhancement( TTP) and mean transit time ( MTT) were measured within the specific regions of interest (ROI) of the brain,and quantitative analysis was performed. Results (1) Thcre were 8 cases in CMS group with diffuse cerebral edema, small schizencephaly and shrinking ventricular system. The density of blood vessel in the brain was differcntly enhanccment (12 cases). There was an obvious correlation be tween the density of cerebral vesscls ( bilateral middle cerebral artery and supcrior sagittal sinus) and the hemoglobin level. The CT values of bilateral middle cerebral artery and superior sagittal sinus were

  16. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study

    Institute of Scientific and Technical Information of China (English)

    GAO Nuo; ZHU Shan-an; HE Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach.Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%,for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.

  17. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  18. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  19. Computed tomography (CT) and diastematomyelia's diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S. (Rio de Janeiro Univ. (Brazil). Faculdade de Medicina); Barros, A.P. de (Rio de Janeiro Univ. (Brazil). Hospital Universitario)

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized.

  20. Single-photon emission computed tomography/computed tomography in brain tumors.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Manni, Carlo; Santoni, Riccardo

    2007-01-01

    Anatomic imaging procedures (computed tomography [CT] and magnetic resonance imaging [MRI]) have become essential tools for brain tumor assessment. Functional images (positron emission tomography [PET] and single-photon emission computed tomography [SPECT]) can provide additional information useful during the diagnostic workup to determine the degree of malignancy and as a substitute or guide for biopsy. After surgery and/or radiotherapy, nuclear medicine examinations are essential to assess persistence of tumor, to differentiate recurrence from radiation necrosis and gliosis, and to monitor the disease. The combination of functional images with anatomic ones is of the utmost importance for a full evaluation of these patients, which can be obtained by means of imaging fusion. Despite the fast-growing diffusion of PET, in most cases of brain tumors, SPECT studies are adequate and provide results that parallel those obtained with PET. The main limitation of SPECT imaging with brain tumor-seeking radiopharmaceuticals is the lack of precise anatomic details; this drawback is overcome by the fusion with morphological studies that provide an anatomic map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT or MRI demonstrated usefulness for brain tumor assessment, but this process is often time consuming and not practical for everyday nuclear medicine studies. The recent development of dual-modality integrated imaging systems, which allow the acquisition of SPECT and CT images in the same scanning session, and their co-registration by means of the hardware, has facilitated this process. In SPECT studies of brain tumors with various radiopharmaceuticals, fused images are helpful in providing the precise localization of neoplastic lesions, and in excluding the disease in sites of physiologic tracer uptake. This information is useful for optimizing diagnosis, therapy monitoring, and radiotherapy treatment planning, with a

  1. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints. Vergleich von konventioneller Tomographie und Computertomographie bei Erkrankungen der Sakroiliakalgelenke

    Energy Technology Data Exchange (ETDEWEB)

    Moritz, J.D.; Ganter, H.; Winter, C. (Bundeswehrkrankenhaus, Giessen (Germany, F.R.). Roentgenabteilung Evangelisches Krankenhaus, Giessen (Germany, F.R.). Roentgenabteilung)

    1990-10-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.).

  2. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics.

  3. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  4. A Clinical Evaluation of Cone Beam Computed Tomography

    Science.gov (United States)

    2013-07-31

    multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011;40:67-75...submitted to the Faculty of the Endodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences...in partial fulfillment of the requirements of the degree of Master of Science in Oral Biology June 2013 Naval Postgraduate Dental

  5. Cerebral toxoplasmosis in AIDS - computerized tomography evaluation; Toxoplasmose cerebral na SIDA - avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Regina Coeli Fonseca [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Hospital Universitario Antonio Pedro. Servico de Radiologia; Narchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia

    1999-06-01

    Cerebral toxoplasmosis is a disease that affects many AIDS's patients. FOr this paper 46 patients with confirmed cases of cerebral toxoplasmosis who did a CT scan between March, 1994 and September, 1997 were examined. Single lesions were found in 28.3% of the patients. The lesions were more frequently detected in the basal ganglia and the frontal lobes. No lesion was larger than 4 cm. As regards the contrast enhancing of the lesions on a CT scan we observed that 54.5% of the lesions had a ring-like contrast enhancing, 36.4% had a nodular contrast enhancing and 6% had a heterogeneous form. After the 21st day of treatment we noticed an improvement in the aspect of the patients'lesions. The improvement of the lesions could be seen through a reduction of the edematous halo, a reduction of the lesion size and a modification in the contrast enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility with cerebral toxoplasmosis, as well as to monitor these patients during treatment. (author)

  6. [Value of computerized axial tomography in cranio-cerebral injuries].

    Science.gov (United States)

    Vigouroux, R P; Baurand, C; Gomez, A; Legre, J; Regis, H; Debaene, A

    1976-01-01

    Since May 1975 was have been working in the field of C.A.T. and its application to study head injuries. We are presenting differents groups of patients studied by C.A.T. I. -- DATA OF C.A.T. IN THE CASES OF EMERGENCY AND IMMEDIATE POST-OPERATIVE FOLLOW-UP OF HEAD INJURIES A) EMERGENCY STATE As soon as the clinical state of an head injured patient was supposed to need an operation, C.A.T. was realized; so differents abnormal scanners may be observed: 1. epidural hematoma, 2. subdural hematoma, 3. intra-cerebral hematoma, 4. acute subdural hematoma or contusion. We must do some comments: -- The Emi-scanner is pre-eminent in showing the exact topography of the lesion : so, the flap is easier to realise. -- In most cases the Emi-scanner is easier to interpret than angiogram for example contusion and hematoma. We know the goods results in hematomas and the poors results in surgery of contusions. -- But the senior advantage of C.A.T. is to provide all the informations in the totality of skull content. Emi-scanner shows bilateral lesions, ipsilateral lesion. C.A.T. is pre-eminent in showing the presence of this two lesions, more accurately than senior methods of investigations, so C.A.T. permits emergency neurosurgical treatment. B) C.A.T. AND FOLLOW-UP Repeated studies at post-intervals can be accomplished without risk to the patient, thus making follow-up simpler and more effective to the neurosurgical attitude. C) POST-OPERATIVE CONTROL AND C.A.T. Post-operative complications are always hard to diagnosis. C.A.T. is painless, quick and safe, and easier to interpret than an angiogram. II -- SEQUELLAE STADE AND C.A.T. In this field certains advantages of C.A.T. are immediatly apparents. In most cases the C.A.T. is the best screening method. Patients carried out are: -- psychiatric troubles, -- post-traumatic epilepsy. The results are not reliable. There is no anatomical-clinical relation in most cases. Differents pictures are observed: -- asymetrical ventricle enlargment

  7. Cerebral computed tomographic angiography scan delay in subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Lukosevicius Saulius

    2005-01-01

    Full Text Available CONTEXT: Computed tomographic angiography (CTA is widely applied in the evaluation of cerebral vessels. Contrast enhancement in cerebral CTA without care or test bolus is not always sufficient for high-quality images. AIMS: Evaluation of the possibilities of calculation of scan delay for cerebral CTA in case of subarachnoid hemorrhage (SAH, based on clinical data of a patient and to find out prognostic error of the model. SETTINGS AND DESIGN: Prospective study in Neurosurgery and Radiology departments. MATERIALS AND METHODS: Scan delay in 53 patients suffering an acute SAH was measured employing test bolus technique. Cerebral CTA was performed afterwards. STATISTICAL ANALYSIS USED: SPSS for Windows v.10.1 software package was applied for dispersion analysis, including one-sample Kolmogorov-Smirnov′s test and Levene′s Test of Equality of Error Variances. RESULTS: A statistical model for the prediction of scan delay in SAH was developed. Cerebral CTA scan delay was dependent upon age, neurological status and impact of the latter factors together (P<0.05. The determined mean square error of prognosis of scan delay of the developed model equals 3.3 sec. CONCLUSION: Using our proposed model it is possible to estimate an optimal delay time for CTA in most patients with SAH with a determined error.

  8. Three-dimensional computed tomography angiography for the investigation of superficial temporal artery pseudoaneurysms--two case reports--.

    Science.gov (United States)

    Higashino, Takuya; Kawashima, Masatou; Mannoji, Hiromichi

    2005-03-01

    An 89-year-old man and a 60-year-old man presented with superficial temporal artery (STA) pseudoaneurysms which developed secondary to trauma. Conventional cerebral angiography and three-dimensional computed tomography (3D CT) angiography clearly demonstrated the STA pseudoaneurysms. The patients underwent surgical excision of the aneurysms based on the conventional cerebral angiography findings in one patient and 3D CT angiography findings in other patient. 3D CT angiography is an excellent noninvasive diagnostic method for detecting extracranial aneurysms such as STA pseudoaneurysm, especially the relationship between the aneurysm and surrounding structures, including the calvarium.

  9. Foveola pharyngea - demonstration in conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fiegler, W.; Stolle, E.

    1980-08-01

    The foveola pharyngea is a cavity on the underside of the clivus, located before the tuberculum pharyngeum and, as a larger pit it was detectable in approx. 1% overall in approx. 4% of the personally examined X-rays (11/284) and computed tomograms (6/154) of the skull base. The canalis basilaris medianus inferior and canalis basilaris medianus bifurcatus almost always empties into one of the three forms of the foveola pharyngea (foveola pharyngea infundibuliformis posterior). The differential diagnosis to canalis basilaris medianus, canalis craniopharyngeus, sutura sphenooccipitalis and bone destruction is discussed.

  10. Development of a proton Computed Tomography detector system

    Science.gov (United States)

    Naimuddin, Md.; Coutrakon, G.; Blazey, G.; Boi, S.; Dyshkant, A.; Erdelyi, B.; Hedin, D.; Johnson, E.; Krider, J.; Rukalin, V.; Uzunyan, S. A.; Zutshi, V.; Fordt, R.; Sellberg, G.; Rauch, J. E.; Roman, M.; Rubinov, P.; Wilson, P.

    2016-02-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  11. Development of a proton Computed Tomography Detector System

    CERN Document Server

    Naimuddin, Md; Blazey, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rukalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P

    2015-01-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  12. Lens dosimetry during examination of the sella turcica: comparison between conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Louis, O.; Bette, L.; Noseda, A.

    1986-01-01

    Lens irradiation measurements were performed with thermo-luminescent lithium fluoride dosimeters during tomographic examinations of the sella turcica, simulated on a phantom head. Lens dosimetry during linear or hypocycloidal conventional tomography was compared with that during computed tomography (CT). Results showed that CT involved much lower radiation exposure to the lens than did conventional tomography and that the major part of the irradiation delivered by CT was related to axial scanning. Therefore, the major finding was that lens irradiation during CT of the sella can be kept at a particularly low level (< 1 m Gy/8 sections) when only coronal scanning is performed.

  13. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  14. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  15. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present s...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  16. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  17. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.

  18. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  19. Intracranial blood flow measured with single photon emission computer tomography (SPECT) during transient -6 degrees head-down tilt.

    Science.gov (United States)

    Satake, H; Konishi, T; Kawashima, T; Matsunami, K; Uno, T; Imai, S; Yamada, H; Hirakawa, C

    1994-02-01

    Regional cerebral blood flow (CBF) during a transient head-down tilt of -6 degrees (-6 degrees HDT) was measured with single photon emission computer tomography (SPECT). CBF was measured and averaged for both sides of the brain areas; e.g., the bilateral anterior cerebral artery (bACA) area, the middle cerebral artery (bMCA) area, the posterior cerebral artery (bPCA) area, bilateral basal ganglia, and the cerebellum. Among these areas, a significant increase in CBF was observed in the basal ganglia and the cerebellum during -6 degrees HDT compared to pre-HDT. When CBF was measured separately in the left or right brain area, these significances disappeared, although a trend of increase or decrease was still observable. A trend of increase was observed in the left anterior cerebral artery (IACA) area, the right middle cerebral artery (rMCA) area, the right posterior cerebral artery (rPCA) area, the left and right basal ganglia, and the cerebellum. In rACA, IMCA and IPCA areas, a slight decrease in CBF was observed. At the same time, cardiac parameters were measured. Heart rate (HR), stroke volume (SV) and cardiac output (CO) did not change significantly, although SV slightly increased and HR slightly decreased during -6 degrees HDT.

  20. In vivo photoacoustic tomography of mouse cerebral edema induced by cold injury

    Science.gov (United States)

    Xu, Zhun; Zhu, Quing; Wang, Lihong V.

    2011-06-01

    For the first time, we have implemented photoacoustic tomography (PAT) to image the water content of an edema in vivo. We produced and imaged a cold-induced cerebral edema transcranially, then obtained blood vessel and water accumulation images at 610 and 975 nm, respectively. We tracked the changes at 12, 24, and 36 h after the cold injury. The blood volume decreased after the cold injury, and the maximum area of edema was observed 24 h after the cold injury. We validated PAT of the water content of the edema through magnetic Resonance Imaging and the water spectrum from the spectrophotometric measurement.

  1. Noninvasive xenon-133 measurements of cerebral blood flow using stationary detectors compared with dynamic emission tomography

    DEFF Research Database (Denmark)

    Schroeder, T; Vorstrup, S; Lassen, N A;

    1986-01-01

    Repeated bedside measurements of CBF have been made possible by the recent development of a mobile unit with 10 stationary detectors using the intravenous xenon-133 method. To evaluate this technique, comparative CBF studies at rest and following the application of a cerebral vasodilatory stimulus...... (acetazolamide, 1 g i.v.) were performed with the mobile equipment and with xenon-133 single-photon emission inhalation tomography in patients with cerebrovascular disease. The CBF level and the flow response to acetazolamide as determined with the two methods were well correlated, although at low flow levels...

  2. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed ...

  3. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  4. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  5. Investigation of a near-infrared-ray computed tomography scanner

    Science.gov (United States)

    Sato, Eiichi; Oda, Yasuyuki; Satoi, Yuichi; Yamaguchi, Satoshi; Ishii, Tomotaka; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Watanabe, Manabu; Kusachi, Shinya

    2016-10-01

    In the near-infrared-ray computed tomography (NIR-CT) scanner, NIR rays are produced from a light-emitting diode (LED) and detected using an NIR phototransistor (PT). The wavelengths of the LED peak intensity and the PT high sensitivity in the data table are both 940 nm. The photocurrents flowing through the PTR are converted into voltages using an emitter-follower circuit, and the output voltages are sent to a personal computer through an analog-digital converter. The NIR projection curves for tomography are obtained by repeated linear scans and rotations of the object, and the scanning is conducted in both directions of its movement.

  6. Computed tomography and magnetic resonance imaging of the pericardium.

    Science.gov (United States)

    Olson, M C; Posniak, H V; McDonald, V; Wisniewski, R; Moncada, R

    1989-07-01

    Computed tomography is an established modality for the evaluation of the pericardium. It is used to evaluate complicated pericardial effusions, pericardial thickening, calcific pericarditis, pericardial cysts, postoperative changes and primary and metastatic neoplasms of the pericardium. Magnetic resonance imaging is being used with increasing frequency in the evaluation of pericardial disease. It offers advantages over computed tomography, including a potential for tissue characterization, absence of ionizing radiation or need for intravenous contrast medium, and the ability to scan in any plane. Disadvantages include greater cost, longer examination times and the inability to identify calcification positively.

  7. Direct sagital computed tomography of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Manzione, J.V. (Harvard Medical School, Boston, MA); Seltzer, S.E.; Katzberg, R.W.; Hammerschlag, S.B.; Chiango, B.F.

    1983-01-01

    Temporomandibular joint dysfunction is a common clinical problem that has been reported to affect 4%-28% of adults. Temporomandibular joint arthrography has shown that many of these patients have intraarticular abnormalities involving the meniscus. A noninvasive test that could demonstrate the meniscus as well as bony abnormalities of the joint would be an important advance. In an attempt to develop such a noninvasive test, we have performed direct sagittal computed tomography (CT) on cadaver temporomandibular joints and have correlated the images with anatomic sections. We are currently applying this technique clinically and report one representative example in which direct sagittal computed tomography of the temporomandibular joint accurately demonstrated an anteriorly displaced meniscus.

  8. Central nervous system involvement in systemic lupus erythematosus. The application of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S.; Ishigatsubo, Y.; Katou, K.; Sakamoto, H.; Chiba, J. (Yokohama City Univ. (Japan). Faculty of Medicine)

    1982-06-01

    Cranial computed tomography scans were performed on 47 patients with systemic lupus erythematosus (SLE). Abnormal findings in the computed tomograms (CT) were observed in 17 patients (36.2%). Cerebral atrophy was the most common feature (eight cases), followed by abnormal high density areas (five cases), abnormal low density areas (three cases), sulcal enlargement (two cases), intracranial hemorrhage (one case) and others (two cases). The abnormal cranial CT group of SLE was associated with a significantly higher incidence of urinary casts and of thrombocytopenia. In particular, the frequency of urinary casts was greater in the group with cerebral atrophy than in the group with normal CT findings, and there was a higher incidence of alopecia, leukopenia and thrombocytopenia in the group with intracranial calcifications. Neuropsychiatric involvements were noted in 70.6% of patients with CT abnormalities, but neuropsychiatric features (20.7%) and electroencephalographic abnormalities (44.8%) were also observed in patients with normal CT findings. The age at onset of SLE, the mean duration of the disease and the survival rate were not significantly different between the groups with and without CT abnormalities, but the mortality rate was significantly greater in the group with CT abnormalities, especially among those with brain atrophy. Concerning the relationship between the findings of cranial CT and corticosteroid treatment, there was no significant difference in either the total dose or the mean duration of prednisolone therapy. Although SLE patients with cerebral atrophy were taking a larger maintenance dose of corticosteroids, the differences were not statistically significant.

  9. Clinico-radiological correlation of Wilson's disease by magnetic resonance imaging, computed tomography and positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Ken; Sakata, Chigusa; Nemoto, Hiroshi; Yokoi, Fuji; Sunohara, Nobuhiko (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan)); Iio, Masaaki

    1991-02-01

    Five patients with Wilson's disease received repeated magnetic resonance imaging (MRI) and computed tomography (CT) examinations at intervals from 6 to 29 months. Four patients, except for asymptomatic one, also underwent positron emission tomography (PET). The significance and limitations of these imaging modalities were examined in the light of their correlation with clinical manifestations and their therapeutic evaluation. The following focal regions, detected on MRI, had a strong positive correlation with clinical manifestations: the lenticular nuclei for dystonia, the brain stem for abnormality of smooth persuit eye movements, and the caudate and lenticular nuclei for severe dysarthria/dysphagia. Follow-up MRI for 3 patients showed an improvement of findings in the lenticular nuclei, lateral part of the putamen, and brain stem, that was in accordance with improved clinical or neurologic manifestations, such as dystonia and cerebellar symptoms. Severe abnormality in the caudate nucleus was associated with poor prognosis. Repeated CT failed to show serial changes in any of the patients. Regional blood flow and oxygen metabolic rate, obtained by PET examinations, were slightly decreased in the thalamus that had normal findings on both MRI and CT, as well as in the cerebral cortex and basal ganglia. PET was, however, inferior to MRI in detecting fine foci within the basal ganglia. In conclusion, there was a good correlation between MRI findings, particularly foci of the caudate and lenticular nuclei, and clinical manifestations. Repeated MRI examinations were the most useful approach to the evaluation of therapeutic effects and prognosis. (N.K.).

  10. CO2BOLD assessment of moyamoya syndrome: Validation with single photon emission computed tomography and positron emission tomography imaging

    Science.gov (United States)

    Pellaton, Alain; Bijlenga, Philippe; Bouchez, Laurie; Cuvinciuc, Victor; Barnaure, Isabelle; Garibotto, Valentina; Lövblad, Karl-Olof; Haller, Sven

    2016-01-01

    AIM To compare the assessment of cerebrovascular reserve (CVR) using CO2BOLD magnetic resonance imaging (MRI) vs positron emission tomography (PET) and single photon emission computed tomography (SPECT) as reference standard. METHODS Ten consecutive patients (8 women, mean age of 41 ± 26 years) with moyamoya syndrome underwent 14 pre-surgical evaluations for external-internal carotid artery bypass surgery. CVR was assessed using CO2BOLD and PET (4)/SPECT (11) with a maximum interval of 36 d, and evaluated by two experienced neuroradiologists. RESULTS The inter-rater agreement was 0.81 for SPECT (excellent), 0.43 for PET (fair) and 0.7 for CO2BOLD (good). In 9/14 cases, there was a correspondence between CO2BOLD and PET/SPECT. In 4/14 cases, CVR was over-estimated in CO2BOLD, while in 1/14 case, CVR was underestimated in CO2BOLD. The sensitivity of CO2BOLD was 86% and a specificity of 43%. CONCLUSION CO2BOLD can be used for pre-surgical assessment of CVR in patients with moyamoya syndrome and combines the advantages of absent irradiation, high availability of MRI and assessment of brain parenchyma, cerebral vessels and surrogate CVR in one stop. PMID:27928470

  11. Personal computer aided cerebral perfusion imaging with dynamic CT

    Institute of Scientific and Technical Information of China (English)

    林燕; 高培毅

    2004-01-01

    @@Reports on the clinical implementation of dynamic computerised tomography (CT) perfusion imaging and quantitative measurement have increased dramatically of late.1-8 The advantages of dynamic CT perfusion imaging and quantitative measurement for the diagnosis of acute cerebral infarction have been acknowledged. However, most overseas CT vendors set perfusion imaging software package as an option for graphic workstation at a too high price for domestic practitioners. To foster the domestic implementation and development of this new technology, we have extended the earlier work.1,2 Applying the theory of central volume principle to DICOM 3.0 standard forms of prime CT images, we developed dynamic CT perfusion imaging and quantitative measure-ment programmes for PCs using Visual C+ + in Windows 98 system.

  12. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ka-Kit Wong; Arpit Gandhi; Benjamin L Viglianti; Lorraine M Fig; Domenico Rubello; Milton D Gross

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to

  13. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  14. Diagnosis of intracranial tuberculosis by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. J.; Hahm, C. K.; Kim, J. J. [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1981-12-15

    25 cases of clinically proved intracranial tuberculosis were studied by CT in the Hanyang Hospital from Feb. 1979 to July 1981. The medical records and CT films were reviewed. The results were as follows; 1. The age distribution was broad from 8 months to 43 years old. The incidence was higher in the age group from 0 to 5 years old. The male to female ratio was 1.8 : 1. 2. Clinical symptoms and signs revealed headache, nausea and vomiting, neck stiffness, positive Kernig's sign, and paralysis of the extremities. 3. At the time of CT examination 8 out of 25 cases were conscious, stuporous in 14 and unconscious in 3. 4. In CT, total or partial obliterations of the basal cisterns were observed in 21 out of 25 cases. 5. Intense abnormal contrast enhancement of the basal cistern were observed in 9 out of 25 cases. 6. Tuberculoma was found in 3 cases. Among these 3 cases had multiple tuberculomas and 1 case had single tuberculoma. 7. Moderate to marked dilatation of both lateral ventricles were observed in 21 cases. The 3rd and 4th ventricles were also dilated in 19 and 12 cases respectively. 8. 2 cases of cerebral infarction were observed, all in the bilateral basal gangilas. 9. Intracranial calcifications were observed in 2 cases who had histories of tuberculous meningitis, 4 to 9 years prior to CT examinations. The calcifications were multiple and located in the suprasellar areas.

  15. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Jakobsen, Annika Loft; Hansen, Mads;

    2006-01-01

    In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study was to investigate the value...

  16. Fractional flow reserve derived from coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Eftekhari, Ashkan; Min, James; Achenbach, Stephan

    2016-01-01

    AIMS: Fractional flow reserve (FFR) derived from coronary computed tomography (FFRCT) has high diagnostic performance in stable coronary artery disease (CAD). The diagnostic performance of FFRCT in patients with hypertension (HTN) and diabetes (DM), who are at risk of microvascular impairment, is...

  17. Coronary computed tomography - present status and future directions

    NARCIS (Netherlands)

    Apfaltrer, P.; Schoepf, U. J.; Vliegenthart, R.; Rowe, G. W.; Spears, J. R.; Fink, C.; Nance, J. W.

    2011-01-01

    The use of coronary computed tomography angiography (cCTA) is growing rapidly, in large part because of fast-paced technical innovations that have increased diagnostic accuracy while providing new opportunities for radiation dose reduction. cCTA using recent generation CT scanners has been repeatedl

  18. Use of Computed Tomography Scans for Cochlear Implants

    OpenAIRE

    Whiting, Bruce R.; Holden, Timothy A.; Brunsden, Barry S.; Finley, Charles C.; Skinner, Margaret W.

    2007-01-01

    While 3-dimensional (3D) imaging by computed tomography has long been desirable for research and treatment of cochlear-implant patients, technical challenges have limited its wide application. Recent developments in scanner hardware and image processing techniques now allow image quality improvements that make clinical applications feasible. Validation experiments were performed to characterize a new methodology and its imaging performance.

  19. Computed tomography diagnosis of partial anomalous pulmonary venous drainage.

    Science.gov (United States)

    Posniak, H V; Dudiak, C M; Olson, M C

    1993-01-01

    A case of the rarely occurring partial anomalous pulmonary venous drainage of the right upper lobe into the azygos arch is presented. Computed tomography (CT) clearly demonstrated the abnormal vessel coursing through the right upper lobe and draining into the azygos arch.

  20. Coronary artery fly-through using electron beam computed tomography

    NARCIS (Netherlands)

    van Ooijen, P M; Oudkerk, M; van Geuns, R J; Rensing, B J; de Feyter, P J

    2000-01-01

    BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND RESULTS:

  1. Computed tomography of the human developing anterior skull base

    NARCIS (Netherlands)

    J. van Loosen (J.); A.I.J. Klooswijk (A. I J); D. van Velzen (D.); C.D.A. Verwoerd (Carel)

    1990-01-01

    markdownabstractAbstract The ossification of the anterior skull base, especially the lamina cribrosa, has been studied by computed tomography and histopathology. Sixteen human fetuses, (referred to our laboratory for pathological examination after spontaneous abortion between 18 and 32 weeks of ge

  2. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  3. Computed Tomography Features of Spontaneously Perforated Pyometra: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.S.; Tan, C.K.; Mak, C.W.; Chia, C.C.; Kuo, C.Y.; Yu, W.L. [Chi-Mei Medical Center, Tainan, Taiwan (China). Depts. of Intensive Care Medicine, Radiology, Obstetrics and Gynecology, and Surgery

    2006-03-15

    Spontaneous perforation of pyometra is an extremely rare emergent gynecologic disease. We report a 73-year-old woman with a spontaneously perforated pyometra presenting with acute abdomen in the emergency department. A dedicated computed tomography examination of the abdominal and pelvic regions revealed the diagnosis. The patient recovered well after surgical intervention and antibiotic treatment.

  4. Dimensional measurement of micro-moulded parts by computed tomography

    DEFF Research Database (Denmark)

    Ontiveros, S.; Yagüe-Fabra, J.A.; Jiménez, R.

    2012-01-01

    Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular for ...

  5. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H;

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary ...

  6. COMPUTED TOMOGRAPHY IN HYDATID CYST OF THE ORBIT

    Directory of Open Access Journals (Sweden)

    K. Abbassioun

    1982-07-01

    Full Text Available Two cases of hydatid cysts of the orbit causing unilateral exophthalmos are reported. Diagnosis were suspected by means of computed tomography (CT and confirmed at Operation. CT changes are described and its value in diagnosis of this lesion particularly in the endemic areas is stressed.

  7. Operator radiation exposure in cone-beam computed tomography guidance

    NARCIS (Netherlands)

    Braak, S.J.; Strijen Van, M. J L; Meijer, E.; Heesewijk Van, J. P M; Mali, W. P T M

    2016-01-01

    Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile rad

  8. Traceability investigation in Computed Tomography using industry-inspired workpieces

    DEFF Research Database (Denmark)

    Kraemer, Alexandra; Stolfi, Alessandro; Schneider, Timm

    2017-01-01

    This paper concerns an investigation of the accuracy of Computed Tomography (CT) measurements using four industry-inspired workpieces. A total of 16 measurands were selected and calibrated using CMMs. CT measurements on industry-inspired workpieces were carried out using two CTs having different...

  9. Moulding process characterization of paper bottles using computed tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    2016-01-01

    The paper presents an approach of evaluating the moulding process for production of paper bottlesusing Computed Tomography (CT). Moulded Pulp Products (MPP) are made of a formed, dewateredand dried mixture of pulp fibers and water. Modern industrial pulp moulding is datedback to the year 1903 whe...

  10. Computed Tomography characterization of the Green Fiber Bottle

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    The work carried out in this research aims at identifying suitable ways for thorough characterization of the quality of paper bottles. Industrial X-ray Computed Tomography (XCT) is particularly advantageous in determining the quality of paper bottles and thus correlating it with the production pr...

  11. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  12. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner ...

  13. Tolerance Verification of an Industrial Assembly using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo; Regi, Francesco

    2016-01-01

    This paper reports on results of tolerance verification of a multi-material assembly by using Computed Tomography (CT). The workpiece comprises three parts which are made out of different materials. Five different measurands were inspected. The calculation of measurement uncertainties was attempt...

  14. Emission Computed Tomography: A New Technique for the Quantitative Physiologic Study of Brain and Heart in Vivo

    Science.gov (United States)

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Schelbert, H. R.; Kuhl, D. E.

    1978-01-01

    Emission computed tomography can provide a quantitative in vivo measurement of regional tissue radionuclide tracer concentrations. This facility when combined with physiologic models and radioactively labeled physiologic tracers that behave in a predictable manner allow measurement of a wide variety of physiologic variables. This integrated technique has been referred to as Physiologic Tomography (PT). PT requires labeled compounds which trace physiologic processes in a known and predictable manner, and physiologic models which are appropriately formulated and validated to derive physiologic variables from ECT data. In order to effectively achieve this goal, PT requires an ECT system that is capable of performing truly quantitative or analytical measurements of tissue tracer concentrations and which has been well characterized in terms of spatial resolution, sensitivity and signal to noise ratios in the tomographic image. This paper illustrates the capabilities of emission computed tomography and provides examples of physiologic tomography for the regional measurement of cerebral and myocardial metabolic rate for glucose, regional measurement of cerebral blood volume, gated cardiac blood pools and capillary perfusion in brain and heart. Studies on patients with stroke and myocardial ischemia are also presented.

  15. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science, Tec...

  16. Mycosis fungoides: manifestations on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shapeero, L.G.; Young, S.W.

    1983-07-01

    Mtcosis fungoides is a malignant lymphoma of the skin that causes intense erythema, plaques, edema, and induration. The primary computed tomographic findings of mycosis fungoides, i.e., skin thickening, tumorous infiltration, edema of the soft tissues, and lymphadenopathy, are presented in two patients.

  17. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    metrology and coordinate metrology and is currently becoming more and more important measuring technique for dimensional measurements. This is mainly due to the fact that with CT, a complete three-dimensional model of the scanned part is in a relatively short time visualized using a computer...

  18. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  19. Value of interictal/ictal single photon emission computed tomography regional cerebral blood flow imaging in localization of epileptic foci%发作间期/发作期SPECT rCBF显像在癫痫灶定位诊断中的价值

    Institute of Scientific and Technical Information of China (English)

    杨雅娜; 罗焱; 胡云; 苏红媛; 杨辉; 张青

    2012-01-01

    Objective To study the value of interictal/ictal single photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) imaging in localization of epileptic foci. Methods Interictal/ictal SPECT, EEG, VEEG, CT or MRI, and ECoG of 115 epilepsy patients, who underwent operation in Department of Neurosurgery, Xinqiao Hospital, Third Military Medical University, were retrospectively analyzed and compared. Results The positive detection rate of interictal/ictal SPECT for epilepsy was higher than that of EEG, VEEG, CT and MRI (90.4% va 37.4% , 82.6% , 48. 8% and 54.2% , P <0.05). The localization rate of interictal/ictal SPECT for epileptic foci was higher than that of ECoG (91. 3% vs 71. 2% , P<0.05). Conclusion The interictal/ictal SPECT is highly consistent with ECoG in localization of epileptic foci, thus playing an important role in preoperative localization of epilepsy.%目的 探讨发作间期/发作期SPECT局部脑血流灌注显像(regional cerebral blood flow,rCBF)在癫痫术前定位诊断中的价值.方法 回顾性分析第三军医大学新桥医院神经外科行外科手术治疗的115例癫痫患者,术前分别行发作间期/发作期SPECT显像、常规脑电图(electroencephalogram,EEG)、视频脑电图(vedio-EEC,VEEG)、CT或MRI检查,术中行皮层脑电图(electrocorticogram,ECoG)监测,与发作间期/发作期SPECT、EEG、VEEG、CT和MRI检查结果进行比较分析.结果 发作间期/发作期SPECT检出癫痫的阳性率为90.4%,高于EEG的37.4% (P <0.05)、VEEG的82.6%(P>0.05)、CT的48.8% (P <0.05)和MRI的54.2% (P <0.05).与术中ECoG结果比较,发作间期/发作期SPECT对癫痫灶定侧率为91.3%,定位率为71.2%.结论 术前发作间期/发作期SPECT显像与ECoG在癫痫灶定位诊断上具有较高的一致性,在术前综合定位诊断中具有重要意义.

  20. Cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitário Cajuru

    Directory of Open Access Journals (Sweden)

    Lauro Aparecido Lara Filho

    2013-06-01

    Full Text Available Objective To identify and analyze the prevalence of cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitário Cajuru. Materials and Methods Cross-sectional study analyzing 200 consecutive non contrast-enhanced cranial computed tomography reports of patients admitted to the emergency unit of Hospital Universitário Cajuru. Results Alterations were observed in 76.5% of the patients. Among them, the following findings were most frequently observed: extracranial soft tissue swelling (22%, bone fracture (16.5%, subarachnoid hemorrhage (15%, nonspecific hypodensity (14.5%, paranasal sinuses opacification (11.5%, diffuse cerebral edema (10.5%, subdural hematoma (9.5%, cerebral contusion (8.5%, hydrocephalus (8%, retractable hypodensity /gliosis/ encephalomalacia (8%. Conclusion The authors recognize that the most common findings in emergency departments reported in the literature are similar to the ones described in the present study. This information is important for professionals to recognize the main changes to be identified at cranial computed tomography, and for future planning and hospital screening aiming at achieving efficiency and improvement in services.

  1. Computed tomography of the acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ho Young; Suh, Jin Suck; Park, Chang Yun; Lee, Kil Woo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

  2. Computed tomography of human joints and radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, E; Bernardi, R; Hollerbach, K; Logan, C; Martz, H; Roberson, G P

    1999-06-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have been increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed. (1) The computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. (2) They are developing NDE and NDE techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity.

  3. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  4. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E;

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...... subjects using three different MRI techniques: arterial spin labeling (ASL), dynamic contrast enhanced T1 weighted perfusion MRI (DCE) and phase contrast mapping (PCM). All MRI measurements were performed within the same session. In 10 of the subjects repeated CBF measurements by (15) O labeled water PET......L/100 g/min, 16.2% and 4.8%, for DCE 43.0 mL/100 g/min, 20.0%, 15.1% and for PET 41.9 mL/100 g/min, 16.5% and 11.9%, respectively. Only for DCE and PCM a significant positive correlation between measurements was demonstrated. CONCLUSION: These findings confirm large between subject variability in CBF...

  5. Optical coherence tomography reveals in vivo cortical structures of adult rats in response to cerebral ischemia injury

    Science.gov (United States)

    Ni, Yi-rong; Guo, Zhou-yi; Shu, So-yun; Bao, Xin-min

    2008-12-01

    Optical coherence tomography(OCT) is a high resolution imaging technique which uses light to directly image living tissue. we investigate the potential use of OCT for structural imaging of the ischemia injury mammalian cerebral cortex. And we examine models of middle cerebral artery occlusion (MCAO) in rats in vivo using OCT. In particular, we show that OCT can perform in vivo detection of cortex and differentiate normal and abnormal cortical anatomy. This OCT system in this study provided an axial resolution of 10~15μ m, the transverse resolution of the system is about 25 μm. OCT can provide cross-sectional images of cortical of adult rats in response to cerebral ischemia injury.We conclude that OCT represents an exciting new approach to visualize, in real-time, pathological changes in the cerebral cortex structures and may offer a new tool for Possible neuroscience clinical applications.

  6. Role of computed tomography in pancreatic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Kim, Ki Whang; Lee, Jong Tae; Oh, Sei Jung [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1991-03-15

    At Yonsei University Hospital from January 1984 to August 1990, computed tomographic (CT) scans of 13 patients with surgically proven pancreatic injuries after blunt abdominal trauma, including 6 pancreatic lacerations or contusions, 6 pancreatic fractures, and one post-traumatic pseudocyst, were retrospectively reviewed to determine the role and accuracy of the CT in evaluating pancreatic injury. CT can document gross pancreatic injury by showing focal or diffuse enlargement (1), area of diminished attenuation (3), separation (5), focal hematoma (2), and peripancreatic change, including peripancreatic hematoma (2), fluid collection (11), perirenal fascial thickening (10), omental and mesenteric change (5), and bowel change (2). CT correctly diagnosed pancreatic fracture in 5 cases, post-raumatic pseudocyst in 1 case, and pancreatic laceration in 3 cases in 9 of these patients. There were 4 false negative diagnoses, including 3 pancreatic lacerations and 1 pancreatic fracture. A CT is of pancreatic trauma could be difficult to diagnosis in patients who are scanned within 24 hrs after an injury or to distinguish a motion or streak artifact caused by a nasogastric tube or air-oral contrast fluid level in the stomach.

  7. Measurement of cerebral blood flow rate and its relationship with brain function using optical coherence tomography

    Science.gov (United States)

    Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe

    2016-03-01

    Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.

  8. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  9. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    CERN Document Server

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  10. Mandibular condyle position in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Hyoung Joo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Kyung Hee Univ. School of Dentistry, Seoul (Korea, Republic of)

    2006-06-15

    To evaluate position of the mandibular condyle within articular fossa in an asymptomatic population radiographically by a cone beam computed tomography. Cone beam computed tomography of 60 temporomandibular joints was performed on 15 males and 15 females with no history of any temporomandibular disorders, or any other orthodontic or photoconductors treatments. Position of mandibular condyle within articular fossa at centric occlusion was evaluated. A statistical evaluation was done using a SPSS. In the sagittal views, mandibular condyle within articular fossa was laterally located at central section. Mandibular condyles in the right and left sides were showed asymmetric positional relationship at medial, central, and lateral sections. Mandibular condyle within articular fossa in an asymptomatic population was observed non-concentric position in the sagittal and coronal views.

  11. Computer-assisted 3D reconstruction of the terminal branches of the cerebral arteries. Pt. 1. Anterior cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Gloger, S. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Gloger, A. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Vogt, H. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Kretschmann, H.J. (Dept. of Neuroanatomy, Hannover Medical School (Germany))

    1994-04-01

    We present a three-dimensional anatomical computer model of the terminal branches of the anterior cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional and magnetic resonance angiography. Our rendition of the cerebral arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlation. (orig.)

  12. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    OpenAIRE

    Augusto Castelli von Atzingen; Dario Ariel Tiferes; Carlos Alberto Matsumoto; Thiago Franchi Nunes; Marcos Vinicius Alvim Soares Maia; Giuseppe D'Ippolito

    2012-01-01

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensiona...

  13. Use of Cone Beam Computed Tomography in Endodontics

    OpenAIRE

    Scarfe, William C.; Martin D. Levin; David Gane; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imagin...

  14. Soil Macropore Structure Characterized by X-Ray Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    FENG Jie; ZHANG Jia-Bao; ZHU An-Ning; BI Jing-Wei

    2003-01-01

    Undisturbed soil core with many macropores and disturbed soil core with only one macropore (diameter is 10 mm) were probed by x-ray computed tomography (CT). The size, number, shape and continuity of macropores in the transverse and vertical sections of soil were characterized using CT scanning images. The probability densities of macropores in the transverse section of soil core exhibited a logarithmic Γ distribution.Results indicated that CT scanning was a promising nondestructive method for characterizing macropores in soils.

  15. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  16. Role of computed tomography in the study of vascular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Bicego, E.; Bergamo, I.A. and others

    1988-01-01

    The most important indications to the use of computed tomography (CT) in the study of vascular pathology are considered. They may be divided as follows: 1) demonstration of vascular involvement by thoraco-abdominal neoplasms; 2) differential diagnosis between primary vascular and extra-vascular pathology; 3) assessment of primary arterial pathology. For each group, those pathologies are considered, for which CT plays a fundamental role.

  17. Computed tomography of partial unilateral agenesis of the pectoralis muscles.

    Science.gov (United States)

    Demos, T C; Johnson, C; Love, L; Posniak, H

    1985-01-01

    The most common congenitally absent muscles are the pectoralis major and minor. Absence is usually incomplete. This anomaly is often one component of a syndrome associated with other hand (Poland syndrome) and thoracic anomalies. Computed tomography can identify partial absence of the pectoralis muscle and exactly define the altered anatomy. A patient with myasthenia gravis and isolated partial agenesis of the pectoralis muscle is presented.

  18. Computed tomography of common congenital lesions of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Yuen, H.Y. E-mail: drhyyuen@doctors.org.uk; Ahuja, A.T.; Wong, K.T.; Yue, V.; Hasselt, A.C. van

    2003-09-01

    This pictorial review describes the application of high-resolution computed tomography to the investigation and pre-operative work-up of the common lesions of congenital hearing loss, including congenital aural dysplasia, various congenital ossicular anomalies, inner ear dysmorphology, large vestibular aqueduct syndrome, and congenital absence of cochlear nerve and labyrinthitis ossificans from previous infection. The aim is to help radiologists to provide a more accurate diagnosis of underlying aetiology and assist in surgical planning.

  19. Computed tomography of the pathological temporal bone. Malformations. Otospongiosis

    Energy Technology Data Exchange (ETDEWEB)

    Azais, O.; Drouineau, J.; Vandermarcq, P.; Barret, D.; Gasquet, C.

    1988-01-01

    The authors evaluate the value of computed tomography in the investigation of malformations and otospongiosis of the ear. Although the CT scan appears to be essential in the preoperative of malformations of the ear, especially as otological examination frequently contributes little to the evaluation of the middle ear, otospongiosis seems to be a less formal indication, except in the predominantly cochlear forms of the disease.

  20. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...... measurements on silicone rubber using CT was carried out. Measurements performed on a CT scanner were compared to measurements on a coordinate measuring machine (CMM), being used as reference....

  1. Analysis of Multilayered Printed Circuit Boards using Computed Tomography

    Science.gov (United States)

    2014-05-01

    resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2: Colour Bar Appendix D.2...Aluminium Al2O3 Aluminium Oxide BGA Ball Grid Array Coronal XZ Plane COTS Commercial Off The Shelf C Carbon CT Computed Tomography DC Direct Current...encapsulated in steel housing. Red Circle: Thin film resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2

  2. Predicting Neck Abscess with Contrast-Enhanced Computed Tomography

    OpenAIRE

    2014-01-01

    Neck abscesses are difficult to diagnose and treat. Currently, contrast-enhanced computed tomography (CECT) is the imaging modality of choice. The study aims to determine the predictive value of CECT findings in diagnosing neck abscess, causes of neck abscess and the most common neck space involved in the local population. 84 consecutive patients clinically suspected to have neck abscess who underwent CECT and surgical confirmation of pus were included. Demographic and clinical data were reco...

  3. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  4. Hypoplasia of the parotid gland: computed tomography sialography diagnosis.

    Science.gov (United States)

    Sun, Lisha; Sun, Zhipeng; Ma, Xuchen

    2013-10-01

    We report two unusual cases of non-syndromic hypoplasia of the parotid gland. The hypoplastic parotid gland mimicked a preauricular parotid tumor in one case and presented as an incidental image finding in the other case. Absence of the deep lobe and isthmus of the parotid parenchyma could be determined on axial computed tomography (CT) by revealing fat tissue composition of the parotid space. The underdeveloped superficial lobe of the gland was observed on three-dimensional CT sialography.

  5. Contraindications to lumbar puncture as defined by computed cranial tomography.

    OpenAIRE

    Gower, D. J.; Baker, A. L.; Bell, W O; Ball, M R

    1987-01-01

    Papilloedema is not always an adequate predictor of potential complications from lumbar puncture, and many clinicians are using computed tomography (CT) before lumbar puncture in an effort to identify more accurately the "at risk" patient. This paper identifies the following anatomical criteria defined by CT scanning that correlate with unequal pressures between intracranial compartments and predispose a patient to herniation following decompression of the spinal compartment: lateral shift of...

  6. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  7. SADMFR guidelines for the use of Cone-Beam Computed Tomography/ Digital Volume Tomography.

    Science.gov (United States)

    Dula, Karl; Bornstein, Michael M; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the dose to our patients by dentistry. Because of the growing concern for an uncritical and consequently rapidly increasing use of CBCT the Swiss Society of Dentomaxillofacial Radiology convened a first consensus conference in 2011 to formulate indications for CBCT, which can be used as guidelines. In this meeting, oral and maxillofacial surgery, orthodontics and temporomandibular joint disorders and diseases were treated and the most important and most experienced users of DVT in these areas were asked to participate. In general, a highly restrictive use of CBCT is required. Justifying main criterion for CBCT application is that additional, therapy-relevant information is expected that should lead to a significant benefit in patient care. All users of CBCT should have completed a structured, high-level training, just like that offered by the Swiss Society of Dentomaxillofacial Radiology.

  8. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  9. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  10. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  11. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  12. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  13. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  14. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  15. Deoxyglucose method for the estimation of local myocardial glucose metabolism with positron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ratib, O.; Phelps, M.E.; Huang, S.C.; Henze, E.; Selin, C.E.; Schelbert, H.R.

    1981-01-01

    The deoxyglucose method originally developed for measurements of the local cerebral metabolic rate for glucose has been investigated in terms of its application to studies of the heart with positron computed tomography (PCT) and FDG. Studies were performed in dogs to measure the tissue kinetics of FDG with PCT and by direct arterial-venous sampling. The operational equation developed in our laboratory as an extension of the Sokoloff model was used to analyze the data. The FDG method accurately predicted the true MMRGlc even when the glucose metabolic rate was normal but myocardial blood flow (MBF) was elevated 5 times the control value or when metabolism was reduced to 10% of normal and MBF increased 5 times normal. Improvements in PCT resolution are required to improve the accuracy of the estimates of the rate constants and the MMRGlc.

  16. Multimodal use of computed tomography in early acute stroke, part 2.

    Science.gov (United States)

    Scaroni, R; Tambasco, N; Cardaioli, G; Parnetti, L; Paloni, F; Boranga, B; Pelliccioli, G P

    2006-01-01

    Computed tomography (CT) scan remains the most widely technique in the cerebrovascular emergency, as it is largely available, minimally invasive, fast, cheap and reliable. Noncontrast enhanced CT (NeCT) imaging can show early signs of infarction in ischemic stroke; however, it could not show if the ischemic tissue is irreversibly damaged. CT perfusion (CTP) imaging has been shown to predict stroke location and size and can provide information about ischemic cerebral parenchyma not definitively compromised. CT angiography (CTA) could highlight stenosis or occlusion both in intracranial and extracranial vessels. By combining NeCT, CTP, and CTA the entire cerebrovascular axis can be imaged during acute stroke. Currently, the term "multimodal CT" indicates the combined use of these three techniques in order to obtain a complete picture of the extension of ischemic damage in acute stroke patients.

  17. Role of computed tomography in estimation of severity and prognosis in neonatal hypoxic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Hirabayashi, S. (Showa Univ., Tokyo (Japan). School of Medicine)

    1981-12-01

    CT (computed tomography) scans in 53 infants whose 1 minute Apgar scores had been 5 or less were reviewed. Comparing the CT findings between the patients of low and high Apgar scores which are checked both at 1 and 5 minutes after delivery, it was confirmed that the 5 minute Apgar score, particularly, is a good predictor of future neurological sequelae of the infants in perinatal hypoxia. Intracranial hemorrhage on the early scans and cerebral atrophy on the follow-up scans were the majority of abnormalities. Between infants with and without neurological sequelae, periventricular hypodensity that may be responsible for future periventricular leucomalacia was quantitatively compared. Differences in absorption density between the two groups were, unexpectedly, not obvious. Usefulness of CT, on the other hand, in detection of intracranial hemorrhage should be emphasized.

  18. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  19. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  20. [Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging].

    Science.gov (United States)

    Perényi, Ádám; Bella, Zsolt; Baráth, Zoltán; Magyar, Péter; Nagy, Katalin; Rovó, László

    2016-01-10

    Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography.

  1. Does computed tomography permeability predict hemorrhagic transformation after ischemic stroke?

    Institute of Scientific and Technical Information of China (English)

    Peggy Yen; Allison Cobb; Jai Jai Shiva Shankar

    2016-01-01

    AIM: To use perfusion-derived permeability-surface area product maps to predict hemorrhagic transformation following thrombolytic treatment for acute ischemic stroke.METHODS: We retrospectively analyzed our prospectively kept acute stroke database over five consecutive months for patients with symptoms of acute ischemic stroke(AIS) who had computed tomography(CT) perfusion(CTP) done at arrival. Patients included in the analyses also had to have a follow-up CT. The permeability-surface area product maps(PS) was calculated for the side of the ischemia and/or infarction and for the contralateral unaffected side at the same level. The cerebral blood flow map was used to delineate the ischemic territory. Next, a region of interest was drawn at the centre of this territory on the PS parametric map. Finally, a mirror region of interest was created on the contralateral side at the same level. The relative permeability-surface area product maps(r PS) provided an internal control and was calculated as the ratio of the PS on the side of the AIS to the PS on the contralateral side. A student t-test was performed after log conversion of r PS between patients with and without hemorrhagic transformation. Log conversion was used to convert the data into normal distribution to use t-test. For the group of patients who experienced intracranial bleed, a student t-test was performed between those with only petechial hemorrhage and those with more severe parenchymal hematoma with subarachnoid haemorrhage.RESULTS: Of 84 patients with AIS and CTP at admission, only 42 patients had a follow-up CT. The r PSderived using the normal side as the internal control was significantly higher(P = 0.003) for the 15 cases of hemorrhagic transformation(1.71 + 1.64) compared to 27 cases that did not have any(1.07 + 1.30). Patients with values above the overall mean r PS of 1.3 had an increased likelihood of subsequent hemorrhagic transformation. The sensitivity of using this score to predict

  2. Optimizing the regularization for image reconstruction of cerebral diffuse optical tomography.

    Science.gov (United States)

    Habermehl, Christina; Steinbrink, Jens; Müller, Klaus-Robert; Haufe, Stefan

    2014-09-01

    Functional near-infrared spectroscopy (fNIRS) is an optical method for noninvasively determining brain activation by estimating changes in the absorption of near-infrared light. Diffuse optical tomography (DOT) extends fNIRS by applying overlapping “high density” measurements, and thus providing a three-dimensional imaging with an improved spatial resolution. Reconstructing brain activation images with DOT requires solving an underdetermined inverse problem with far more unknowns in the volume than in the surface measurements. All methods of solving this type of inverse problem rely on regularization and the choice of corresponding regularization or convergence criteria. While several regularization methods are available, it is unclear how well suited they are for cerebral functional DOT in a semi-infinite geometry. Furthermore, the regularization parameter is often chosen without an independent evaluation, and it may be tempting to choose the solution that matches a hypothesis and rejects the other. In this simulation study, we start out by demonstrating how the quality of cerebral DOT reconstructions is altered with the choice of the regularization parameter for different methods. To independently select the regularization parameter, we propose a cross-validation procedure which achieves a reconstruction quality close to the optimum. Additionally, we compare the outcome of seven different image reconstruction methods for cerebral functional DOT. The methods selected include reconstruction procedures that are already widely used for cerebral DOT [minimum l2-norm estimate (l2MNE) and truncated singular value decomposition], recently proposed sparse reconstruction algorithms [minimum l1- and a smooth minimum l0-norm estimate (l1MNE, l0MNE, respectively)] and a depth- and noise-weighted minimum norm (wMNE). Furthermore, we expand the range of algorithms for DOT by adapting two EEG-source localization algorithms [sparse basis field expansions and linearly

  3. The role of cerebral spinal fluid in light propagation through the mouse head: improving fluorescence tomography with Monte Carlo modeling

    Science.gov (United States)

    Ancora, Daniele; Zacharopoulos, Athanasios; Ripoll, Jorge; Zacharakis, Giannis

    2016-03-01

    Optical Neuroimaging is a highly dynamical field of research owing to the combination of many advanced imaging techniques and computational tools that uncovered unexplored paths through the functioning of the brain. Light propagation modelling through such complicated structures has always played a crucial role as the basis for a high resolution and quantitative imaging where even the slightest improvement could lead to significant results. Fluorescence Diffuse Optical Tomography (fDOT), a widely used technique for three dimensional imaging of small animals and tissues, has been proved to be inaccurate for neuroimaging the mouse head without the knowledge of a-priori anatomical information of the subject. Commonly a normalized Born approximation model is used in fDOT reconstruction based on forward photon propagation using Diffusive Equation (DE) which has strong limitations in the optically clear regime. The presence of the Cerebral Spinal Fluid (CSF) instead, a thin optically clear layer surrounding the brain, can be more accurately taken into account using Monte Carlo approaches which nowadays is becoming more usable thanks to parallelized GPU algorithms. In this work we discuss the results of a synthetic experimental comparison, resulting to the increase of the accuracy for the Born approximation by introducing the CSF layer in a realistic mouse head structure with respect to the current model. We point out the importance of such clear layer for complex geometrical models, while for simple slab phantoms neglecting it does not introduce a significant error.

  4. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly.

  5. [Spiral computed tomography in the diagnosis of limb osteomyelitis].

    Science.gov (United States)

    Vasil'ev, A Iu; Bulanova, T V; Onishchenko, M P

    2003-01-01

    The results of radiation studies in 121 patients of different age (4 to 75 years) examined for limb osteomyelitis are analyzed. All the patients underwent routine X-ray study and computed tomography (CT), 26 patients had X-ray fistulography; 8, linear tomography; 10, CT fistulography; 6, scintigraphy, and 15, ultrasound study. Acute hematogenous osteomyelitis (AHO), chronic hematogenous osteomyelitis (CHO), and atypical (here Garre's sclerosing osteomyelitis and Brodie's abscess) osteomyelitis were ascertained in 10.6, 26.4, and 10.1% of cases, respectively. Posttraumatic osteomyelitis was diagnosed in almost 50% of the patients. CT defined the phase of chronic limb osteomyelitis. Spiral CT has proven to be the most effective technique for diagnosing limb osteomyelitis as compared with routine X-ray study: the accuracy of X-ray study was 81.8%, its sensitivity, 84.9%, and specificity, 60.0% and those of computed tomography were 96.7, 99.1, and 80.0%, respectively.

  6. Regional cerebral blood flow in acute stage ischemic cerebrovascular disease by xenon-133 inhalation and single photon emission computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, Hiroyuki (Akita Univ. (Japan). School of Medicine)

    1989-03-01

    During the period from February 1984 through June 1985, single photon emission computerized tomography (SPECT) with xenon-133 inhalation method has been performed for the measurement of regional cerebral blood flow (rCBF) during the first 48 hours of onset of cerebral infarction (n=71) and transient ischemic attack (n=21). X-ray CT (CT) and carotid arteriography were concurrently performed in all the patients. In repeated studies performed for 15 normal volunteers, rCBF measurement by SPECT was found reproducible. Mean values of rCBF for the right and left cerebral hemispheres were 60.3{plus minus}6.52 and 61.8{plus minus}6.91 ml/100 g/min, respectively. For cerebral infarction, ischemic foci corresponding to clinical symptoms were detected more frequently on SPECT than on CT (93% vs 63%). In all of the evaluable 35 patients with cerebral infarction, rCBF within the first 8 hours of onset was decreased: 31.0 ml/100 g/min for the internal carotid artery (ICA) occlusion and 36.0 ml/100 g/min for the middle cerebral artery (MCA) occlusion. Crossed cerebellar diaschisis was observed in 50% (9/18) for ICA occlusion and 37% (14/38) for MCA occlusion. For transient ischemic attack, there was no significant difference in the detection of ischemic foci between SPECT and CT (38% vs 43%). In detecting small foci especially in the deep regions such as the basal ganglia, SPECT was inferior to CT. Mean rCBF for transient ischemic attack tended to be lower than the normal rCBF (50.7 ml/100 g/min for the right cerebral hemisphere and 50.6 ml/100 g/min for the left cerebral hemisphere). SPECT may aid in predicting prognosis and chosing treatment strategy, as well as in determining cerebral hemodynamics. (N.K.).

  7. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongmei; Zhu, Shouping, E-mail: zhusp2009@gmail.com; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin [Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China)

    2014-11-10

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

  8. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  9. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  10. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  11. Craniocerebral trauma--congruence between post-mortem computed tomography diagnoses and autopsy results: a 2-year retrospective study

    DEFF Research Database (Denmark)

    Jacobsen, Christina; Lynnerup, Niels

    2010-01-01

    Computed tomography (CT) has been used routinely at the Department of Forensic Medicine, University of Copenhagen since 2002. A retrospective study was performed in order to correlate CT-scan based diagnoses of cranial and cerebral lesions with macroscopic autopsy diagnoses in 56 cases. The CT......-scans were performed by a forensic pathologist. They were obtained by using two different CT-scan protocols. The results showed correct skull fracture diagnoses in 34/56 cases. Fractures were diagnosed partially (9) or missed totally (13) on CT-images in 22 cases. The agreement for fracture diagnoses...

  12. F-18 Fluorodeoxy Glucose Positron Emission Tomography/Computed Tomography Findings in a Rare Case of Penile Leiomyosarcoma

    Directory of Open Access Journals (Sweden)

    Kuruva Manohar

    2011-01-01

    Full Text Available Penile cancer is a rare entity accounting for only 0.4% all male malignancies. Penile leiomyosarcomas are even rarer with only around 35 cases reported in literature. We report a rare case of penile leiomyosarcoma illustrating F-18 Fluorodeoxy glucose (FDG positron emission tomography/computed tomography (PET/CT features and histopathology correlation.

  13. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  14. Imaging of lesions in the posterior cranial fossa using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Michiro; Uesugi, Yasuo; Higashikawa, Masahiko; Ochi, Mari; Makimoto, Kazuo; Takahashi, Hiroaki; Shin, Akinori; Utsunomiya, Keita; Akagi, Hiroaki

    1988-10-01

    Lesions in the posterior cranial fossa were visualized by single photon emission computed tomography (SPECT) with /sup 123/I-IMP (N-isopropyl-p-/sup 123/I-iodoamphetamine) and /sup 99m/Tc-HM-PAO (/sup 99m/Tc-hexametylpropyleneamine oxime). It is generally held that these radiopharmaceuticals penetrate the walls of cerebral blood vessels and that their accumulations in the brain tissue may reflect the cerebral blood flow. Six patients with lesions in the central nervous system all showed wider areas of abnormality in SPECT than in X-ray CT, indicating a larger lesion of blood flow disturbance. In the next series of 11 patients with vertigo or dizziness of unknown etiology, eight had abnormal findings in the scan with /sup 123/I-IMP as did four of the nine in the scan with /sup 99m/Tc-HM-PAO. Thus, most patients with dizziness of unknown etiology may have some vertebral blood flow disorder, which in some cases is not clearly diagnosed by conventional vestibular examinations or even by X-ray CT scan. The accuracy of the diagnostic measures for otoneurological problems awaits further studies of their sensitivity and specificity.

  15. Computed tomography of intracranial complications in infants and children with tuberculous infection

    Energy Technology Data Exchange (ETDEWEB)

    Katafuchi, Yukihiko; Matsuishi, Toyojiro; Ishihara, Osamu; Yano, Eiji; Terasawa, Kenjiro (Kurume Univ., Fukuoka (Japan). School of Medicine)

    1982-10-01

    Cranial computed tomography (CCT) was performed in 6 infants and children with pulmonary tuberculosis. Three cases (Cases 1, 2, and 6) were diagnosed as pulmonary tuberculosis without neurological signs and symptoms, while the other three cases (Cases 3, 4, and 5) were diagnosed as tuberculous meningitis from the clinical course and the CSF findings. The CCT findings of Cases 1, 2 and 6 showed a high-density area in the cerebral parenchyma and basal cistern. These findings indicated intracranial tuberculomas without neurological signs and symptoms. Two cases of tuberculous meningitis (Cases 3 and 4) showed ventricular dilatation that indicated an internal hydrocephalus. Case 5 showed a high-density area in the basal cistern. This indicated a tuberculoma. There were four cases (Cases 1, 2, 5, and 6) of intracranial tuberculomas;in 2 cases, they were in the cerebral parenchyma, and in the other 2, in the basal cistern, along with the meninges. Three of these cases (75%) showed calcification. The relationship between neurological sequelae and CCT findings was studied. Two of the three cases of pulmonary tuberculosis without neurological signs and symptoms, which were diagnosed as intracranial tuberculoma by CCT, were not associated with neurological sequelae. Otherwise, two cases of tuberculous meningitis which had been diagnosed as cases of internal hydrocephalus by CCT were severely handicapped. Therefore, the finding of ventricular dilatation indicated the risk factor of neurological sequelae.

  16. Usefulness of 320-Row Area Detector Computed Tomography for the Diagnosis of Cystic Falx Meningioma

    Directory of Open Access Journals (Sweden)

    Sadaharu Tabuchi

    2013-07-01

    Full Text Available We present a case of cystic falx meningioma. Cystic meningioma is rare and not easy to diagnose preoperatively; it is often misdiagnosed as other tumors, including glial or metastatic tumors with cystic or necrotic changes. This study showed the potential impact of 320-row computed tomography (CT on image-based diagnostic evaluation of cystic meningioma with special attention to the novel techniques of 4-dimensional CT angiography (4D-CTA and CT whole-brain perfusion (CTP. 4D-CTA showed the arterial supply feeding the tumor and late enhancement of the tumor nodule, similar to that seen in meningioma by conventional angiography. CTP showed that the tumor had a higher cerebral blood flow and cerebral blood volume and a longer mean transit time than adjacent brain tissue. These findings were consistent with meningioma and reinforced the other imaging findings, resulting in the correct preoperative diagnosis. The new techniques available for 320-row CT can potentially be used to improve differential diagnosis and preoperative assessment of cystic tumors with nodules.

  17. Quantitative cerebral perfusion assessment using microscope-integrated analysis of intraoperative indocyanine green fluorescence angiography versus positron emission tomography in superficial temporal artery to middle cerebral artery anastomosis

    Directory of Open Access Journals (Sweden)

    Shinya Kobayashi

    2014-01-01

    Full Text Available Background: Intraoperative qualitative indocyanine green (ICG angiography has been used in cerebrovascular surgery. Hyperperfusion may lead to neurological complications after superficial temporal artery to middle cerebral artery (STA-MCA anastomosis. The purpose of this study is to quantitatively evaluate intraoperative cerebral perfusion using microscope-integrated dynamic ICG fluorescence analysis, and to assess whether this value predicts hyperperfusion syndrome (HPS after STA-MCA anastomosis. Methods: Ten patients undergoing STA-MCA anastomosis due to unilateral major cerebral artery occlusive disease were included. Ten patients with normal cerebral perfusion served as controls. The ICG transit curve from six regions of interest (ROIs on the cortex, corresponding to ROIs on positron emission tomography (PET study, was recorded. Maximum intensity (I MAX , cerebral blood flow index (CBFi, rise time (RT, and time to peak (TTP were evaluated. Results: RT/TTP, but not I MAX or CBFi, could differentiate between control and study subjects. RT/TTP correlated (|r| = 0.534-0.807; P < 0.01 with mean transit time (MTT/MTT ratio in the ipsilateral to contralateral hemisphere by PET study. Bland-Altman analysis showed a wide limit of agreement between RT and MTT and between TTP and MTT. The ratio of RT before and after bypass procedures was significantly lower in patients with postoperative HPS than in patients without postoperative HPS (0.60 ± 0.032 and 0.80 ± 0.056, respectively; P = 0.017. The ratio of TTP was also significantly lower in patients with postoperative HPS than in patients without postoperative HPS (0.64 ± 0.081 and 0.85 ± 0.095, respectively; P = 0.017. Conclusions: Time-dependent intraoperative parameters from the ICG transit curve provide quantitative information regarding cerebral circulation time with quality and utility comparable to information obtained by PET. These parameters may help predict the occurrence of postoperative

  18. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... standard limits the reliability of accuracy calculations. RESULTS: FDG-PET would have upstaged 19% of patients and downstaged 5% of patients, leading to a different treatment in 9% of patients. For FDG-PET/CT, the corresponding figures are 17%, 5%, and 7%. In nodal regions, the sensitivity of FDG...

  19. Benign breast lesions detected by positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Benveniste, Ana P., E-mail: apbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Yang, Wei, E-mail: wyang@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mawlawi, Osama R., E-mail: omawlawi@mdanderson.org [Department of imaging physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Marom, Edith M., E-mail: emarom@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    {sup 18}F-fluorodeoxyglucose positron emission computed tomography (FDG PET-CT) is widely used in the initial staging and response evaluation of patients with malignancy. This review describes a spectrum of benign breast findings incidentally detected by FDG PET-CT at staging that may be misinterpreted as malignancy. We describe the pattern of distribution and intensity of FDG uptake in a spectrum of benign breast diseases with their corresponding typical morphological imaging characteristics to help the nuclear medicine physician and/or general radiologist identify benign lesions, avoiding unnecessary breast imaging work-up and biopsies.

  20. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  1. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  2. Cone-beam computed tomography: A miracle for orthodontics!

    Directory of Open Access Journals (Sweden)

    Jeevan M Khatri

    2015-01-01

    Full Text Available The branch of oral medicine and radiology has always played a role of back stage worker for the branch of orthodontics and dentofacial orthopaedics. It would have been difficult for an orthodontist to gift the bright smiles to his/her patients without the 2D and 3D black and white pictures provided by the oral radiologist. Moreover, the series of advances in the various imaging modalities are playing the role of a magician for the branch of orthodontia. The present article provides valuable information about one such miracle for the field of orthodontics-cone beam computed tomography (CBCT.

  3. PRaVDA: High Energy Physics towards proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Price, T., E-mail: t.price@bham.ac.uk

    2016-07-11

    Proton radiotherapy is an increasingly popular modality for treating cancers of the head and neck, and in paediatrics. To maximise the potential of proton radiotherapy it is essential to know the distribution, and more importantly the proton stopping powers, of the body tissues between the proton beam and the tumour. A stopping power map could be measured directly, and uncertainties in the treatment vastly reduce, if the patient was imaged with protons instead of conventional x-rays. Here we outline the application of technologies developed for High Energy Physics to provide clinical-quality proton Computed Tomography, in so reducing range uncertainties and enhancing the treatment of cancer.

  4. Computed Tomography Appearances of Various Complications Associated with Pancreatic Pseudocysts

    Energy Technology Data Exchange (ETDEWEB)

    Cheol Kim, Hyun; Mo Yang, Dal; Jung Kim, Hyoung; Ho Lee, Dong; Tae Ko, Young; Won Lim, Joo (Dept. of Radiology, East-West Neo Medical Center, Kyung-Hee Univ., Seoul (Korea))

    2008-09-15

    Most pancreatic pseudocysts are common complications of acute or chronic pancreatitis. They usually occur within the pancreas or in peripancreatic tissues, and are visualized as round or oval fluid collections with thin or thick walls on computed tomography (CT) scans. However, pancreatic pseudocysts are often combined with various complications, e.g., various organ involvements, infection, hemorrhage with pseudoaneurysm formation, rupture with fistula formation, or gastrointestinal or biliary obstruction, which may necessitate prompt intervention or surgery. This review illustrates the CT appearances of various complications associated with pancreatic pseudocysts

  5. X-ray computed tomography investigations of Cucuteni ceramic statuettes

    Directory of Open Access Journals (Sweden)

    Carmen Pavel

    2013-12-01

    Full Text Available Deciphering the internal structure of prehistoric artefacts can provide spectacular insights that might help us understand the people who made them. In order to preserve the integrity of these relics of past civilisations, it is desirable to make such investigations using non-destructive techniques. Recent decades have witnessed a growth in the X-ray computed tomography (CT applications in the study of cultural heritage objects. This paper presents and discusses tomographic investigations of two Cucuteni ceramic statuettes discovered in Romania. The study was made with a CT device specially designed for archaeometric applications.

  6. Unusual causes of colonic wall thickening on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Turner, D.R.; Markose, G.; Arends, M.J.; Ng, C.S.; Freeman, A.H

    2003-03-01

    Computed tomography (CT) appearances in 'colitis' are often non-specific, and include mural thickening and mesenteric fat stranding. In the western world, the majority of cases will have, or be subsequently diagnosed with, inflammatory bowel disease, pseudomembranous colitis or ischaemic colitis. However, other rare conditions may also produce these rather non-specific signs. We present a number of cases demonstrating colonic wall thickening on CT due to rarer diagnoses, which are correlated with the histopathological features. Some of these CT appearances have not been described previously in the literature.

  7. Incidental findings on cone beam computed tomography: Relate and relay

    Directory of Open Access Journals (Sweden)

    Suhas P Pande

    2015-01-01

    Full Text Available Objective: To evaluate the presence of incidental findings on cone beam computed tomography (CBCT images and to recognize their clinical importance. Materials and Methods: A total of 700 CBCT scans between January 2013 to August 2014 at Government Dental College and Hospital were evaluated retrospectively. Results: 459 incidental findings (65.57% were observed in 700 patients. Most common individual incidental finding was mucosal thickening (119 followed by pineal/habenula calcification (99 and choroid plexus (77. Conclusion: The oral and maxillofacial radiologist should carefully interpret all scans and should not ignore the incidental findings and hence avoid untoward snowballing effects.

  8. Aortic valve area assessed with 320-detector computed tomography

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig;

    2014-01-01

    To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVAMDCT......) and by the continuity equation with TTE (AVATTE). To generate a reference AVA (AVAREF) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVAREF was used as the reference...

  9. Urologic applications of multiplanar and three-dimensional computed tomography.

    Science.gov (United States)

    Olson, M C; Posniak, H V

    1995-01-01

    The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.

  10. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  11. Precision Medicine and PET/Computed Tomography: Challenges and Implementation.

    Science.gov (United States)

    Subramaniam, Rathan M

    2017-01-01

    Precision Medicine is about selecting the right therapy for the right patient, at the right time, specific to the molecular targets expressed by disease or tumors, in the context of patient's environment and lifestyle. Some of the challenges for delivery of precision medicine in oncology include biomarkers for patient selection for enrichment-precision diagnostics, mapping out tumor heterogeneity that contributes to therapy failures, and early therapy assessment to identify resistance to therapies. PET/computed tomography offers solutions in these important areas of challenges and facilitates implementation of precision medicine.

  12. Material reconstruction for spectral computed tomography with detector response function

    Science.gov (United States)

    Liu, Jiulong; Gao, Hao

    2016-11-01

    Different from conventional computed tomography (CT), spectral CT using energy-resolved photon-counting detectors is able to provide the unprecedented material compositions. However accurate spectral CT needs to account for the detector response function (DRF), which is often distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. The simulation results suggest that the proposed methods reconstructed more accurate material compositions than the conventional method without DRF. Moreover, the proposed linearized method with linear data fidelity from spectral resampling had improved reconstruction quality from the nonlinear method directly based on nonlinear data fidelity.

  13. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer......The development of clinical diagnostic procedures comprises early-phase and late-phase studies to elucidate diagnostic accuracy and patient outcome. Economic assessments of new diagnostic procedures compared with established work-ups indicate additional cost for 1 additional unit of effectiveness...

  14. Computed tomography of the thymus gland in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Thorvinger, B.; Lyttkens, K.; Samuelsson, L.

    Sixteen consecutive patients with myasthenia gravis were examined by computed tomography (CT) before thymectomy. Surgical and histologic findings were compared with those obtained at CT. The results, like those of most other recent studies, indicate that CT is a reliable method for identifying thymoma. In all three patients with thymoma, and in five out of eight patients with hyperplasia, the lesion was observed at CT, giving an overall accuracy of 80%. Although tymic hyperplasia is a basically histological diagnosis an enlarged gland may give a correct diagnosis of this abnormality.

  15. The value of computed tomography in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.R.; Muhm, J.R.; Sheedy, P.F. II; Unni, K.K.; Bernatz, P.E.; Hermann, R.C. Jr.

    1983-01-01

    In a 5 year study, 19 patients with myasthenia gravis were studied by computed tomography (CT) and underwent thymectomy. CT was accurate in detecting the nine true thymic masses but could not differentiate thymomas from nonthymomatous masses, including thymic cysts. No thymoma was found in a patient under 25 years of age. In one case, the 18 sec scanner could not differentiate a large gland from a thymoma. In eight cases, glands with histologic thymic hyperplasia and histologically normal thymus appeared to be similar and could not be differentiated by CT.

  16. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    Science.gov (United States)

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  17. PET/Computed Tomography in Renal, Bladder, and Testicular Cancer.

    Science.gov (United States)

    Bouchelouche, Kirsten; Choyke, Peter L

    2015-07-01

    Imaging plays an important role in the clinical management of cancer patients. Hybrid imaging with PET/computed tomography (CT) is having a broad impact in oncology, and in recent years PET/CT is beginning to have an impact in urooncology. In both bladder and renal cancers, there is a need to study the efficacy of other tracers than F-18 fluorodeoxyglucose (FDG), particularly tracers with limited renal excretion. Thus, new tracers are being introduced. This review focuses on the clinical role of FDG and other PET agents in renal, bladder, and testicular cancers.

  18. Improved proton computed tomography by dual modality image reconstruction

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Bassler, Niels; Petersen, Jørgen B.B.;

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full...... nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully...

  19. Correlations between computerized tomography of the head and motor developmental disturbances of children with cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.H. (Nagasaki Univ. (Japan). School of Medicine)

    1981-01-01

    Two hundred and eighty-two children with cerebral palsy (C.P.) and thirty-seven normal children were studied by computerized tomography (C.T.) of the head for finding out the correlations between the organic damage of the brain and the motor developmental disturbance. The abnormal findings of C.T. were: enlargement of the ventricular system, high density area, low density area and porencephalus, enlargement of the sulcus and anomaly of the medial structure. Enlargement of the ventricular system seemed to have correlation with spasticity; the portion and the extent of the enlargement corresponded to the affected extremities and the severity of the spasticity. Children of other types also showed various abnormal C.T. findings but, in general, less than that of spastic types. The prognosis of the motor development of C.P. children cannot be predicted by serial C.T. examinations strictly, because early treatment could cause improvement to that of these children. However, it is of worthy notice that C.T. is an effective method of helping to diagnose the motor developmental disturbance in earlier childhood.

  20. Hypoxic injury of all deep nuclei of the brain. A case report from computed tomography; Hypoxischer Schaden aller tiefen Kerngebiete des Gehirns. Ein Fallbericht aus der Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, S.A.; Bautz, W.A.; Uder, M.; Alibek, S. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Radiologie; Richter, G. [Erlangen-Nuernberg Univ., Erlangen (Germany). Neuroradiologische Abt.

    2008-07-01

    Though being inferior to magnetic resonance imaging, computed tomography (CT) of the brain is the most frequently applied imaging modality in the diagnostic workup of acute cerebral Ischaemia. We report on a case of a comatose 53-year-old man who was brought to the emergency room after cardiopulmonary resuscitation. The CT of the brain showed a diffuse brain oedema with an explicit hypodense demarcation of all deep nuclei. (orig.)

  1. Computed tomography angiography in patients with active gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fatima Regina Silva; D' Ippolito, Giuseppe, E-mail: fatima.rsreis@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Cardia, P.P. [Hospital Vera Cruz, Campinas, SP (Brazil)

    2015-11-15

    Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding. (author)

  2. Quantitative analysis of cholesteatoma using high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamasoba, Tatsuya (Kameda General Hospital, Chiba (Japan)); Iinuma, Toshitaka

    1992-05-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author).

  3. Proton Computed Tomography: iterative image reconstruction and dose evaluation

    Science.gov (United States)

    Civinini, C.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Lo Presti, D.; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.; Bruzzi, M.

    2017-01-01

    Proton Computed Tomography (pCT) is a medical imaging method with a potential for increasing accuracy of treatment planning and patient positioning in hadron therapy. A pCT system based on a Silicon microstrip tracker and a YAG:Ce crystal calorimeter has been developed within the INFN Prima-RDH collaboration. The prototype has been tested with a 175 MeV proton beam at The Svedberg Laboratory (Uppsala, Sweden) with the aim to reconstruct and characterize a tomographic image. Algebraic iterative reconstruction methods (ART), together with the most likely path formalism, have been used to obtain tomographies of an inhomogeneous phantom to eventually extract density and spatial resolutions. These results will be presented and discussed together with an estimation of the average dose delivered to the phantom and the dependence of the image quality on the dose. Due to the heavy computation load required by the algebraic algorithms the reconstruction programs have been implemented to fully exploit the high calculation parallelism of Graphics Processing Units. An extended field of view pCT system is in an advanced construction stage. This apparatus will be able to reconstruct objects of the size of a human head making possible to characterize this pCT approach in a pre-clinical environment.

  4. Incidental cardiac findings on computed tomography imaging of the thorax

    Directory of Open Access Journals (Sweden)

    El-Gendi Hossam

    2010-12-01

    Full Text Available Abstract Background Investigation of pulmonary pathology with computed tomography also allows visualisation of the heart and major vessels. We sought to explore whether clinically relevant cardiac pathology could be identified on computed tomography pulmonary angiograms (CTPA requested for the exclusion of pulmonary embolism (PE. 100 consecutive CT contrast-enhanced pulmonary angiograms carried out for exclusion of PE at a single centre were assessed retrospectively by two cardiologists. Findings Evidence of PE was reported in 5% of scans. Incidental cardiac findings included: aortic wall calcification (54%, coronary calcification (46%, cardiomegaly (41%, atrial dilatation (18%, mitral annulus calcification (15%, right ventricular dilatation (11%, aortic dilatation (8% and right ventricular thrombus (1%. Apart from 3 (3% reports describing cardiomegaly, no other cardiac findings were described in radiologists' reports. Other reported pulmonary abnormalities included: lung nodules (14%, lobar collapse/consolidation (8%, pleural effusion (2%, lobar collapse/consolidation (8%, emphysema (6% and pleural calcification (4%. Conclusions CTPAs requested for the exclusion of PE have a high yield of cardiac abnormalities. Although these abnormalities may not have implications for acute clinical management, they may, nevertheless, be important in long-term care.

  5. Estimation of feline renal volume using computed tomography and ultrasound.

    Science.gov (United States)

    Tyson, Reid; Logsdon, Stacy A; Werre, Stephen R; Daniel, Gregory B

    2013-01-01

    Renal volume estimation is an important parameter for clinical evaluation of kidneys and research applications. A time efficient, repeatable, and accurate method for volume estimation is required. The purpose of this study was to describe the accuracy of ultrasound and computed tomography (CT) for estimating feline renal volume. Standardized ultrasound and CT scans were acquired for kidneys of 12 cadaver cats, in situ. Ultrasound and CT multiplanar reconstructions were used to record renal length measurements that were then used to calculate volume using the prolate ellipsoid formula for volume estimation. In addition, CT studies were reconstructed at 1 mm, 5 mm, and 1 cm, and transferred to a workstation where the renal volume was calculated using the voxel count method (hand drawn regions of interest). The reference standard kidney volume was then determined ex vivo using water displacement with the Archimedes' principle. Ultrasound measurement of renal length accounted for approximately 87% of the variability in renal volume for the study population. The prolate ellipsoid formula exhibited proportional bias and underestimated renal volume by a median of 18.9%. Computed tomography volume estimates using the voxel count method with hand-traced regions of interest provided the most accurate results, with increasing accuracy for smaller voxel sizes in grossly normal kidneys (-10.1 to 0.6%). Findings from this study supported the use of CT and the voxel count method for estimating feline renal volume in future clinical and research studies.

  6. Computed tomography of intra - and extramural ethmoid cells: iconographic essay

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes [McGill University Health Centre (MUHC), Montreal, QC (Canada). Montreal General Hospital; Jovem, Cassio Lemos [Med Imagem, Teresina, PI (Brazil); Moura, Leonardo de Oliveira [Centro de Treinamento em Imagenologia (CETRIM), Joao Pessoa, PB (Brazil)

    2011-09-15

    The development of the paranasal sinuses is an intricate process that begins in the intrauterine life and terminates in early adulthood. Among the paranasal sinuses, the ethmoid cells or labyrinth are probably the most complex structures, being associated with the highest number of normal variants. Variations in the pattern of pneumatization of the ethmoid cells can be divided into intra - and extramural cells. Intramural cells are those which develop within the ethmoid labyrinth. Extramural cells are those that develop isolatedly. Computed tomography is the most useful tool in the evaluation of inflammatory processes of the paranasal sinuses. Computed tomography also plays a relevant role in the preoperative planning as well as in the postoperative follow-up, since it demonstrates exact anatomical details of normal structures with accuracy in the detection of variants. In the present pictorial essay, the authors describe the most common anatomical variants of the ethmoid labyrinth and their relationship with adjacent structures. Endoscopic sinonasal surgery has become increasingly less invasive, requiring more detailed anatomical imaging of this region. (author)

  7. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  8. Limited-data computed tomography algorithms for the physical sciences.

    Science.gov (United States)

    Verhoeven, D

    1993-07-10

    Five limited-data computed tomography algorithms are compared. The algorithms used are adapted versions of the algebraic reconstruction technique, the multiplicative algebraic reconstruction technique, the Gerchberg-Papoulis algorithm, a spectral extrapolation algorithm descended from that of Harris [J. Opt. Soc. Am. 54, 931-936 (1964)], and an algorithm based on the singular value decomposition technique. These algorithms were used to reconstruct phantom data with realistic levels of noise from a number of different imaging geometries. The phantoms, the imaging geometries, and the noise were chosen to simulate the conditions encountered in typical computed tomography applications in the physical sciences, and the implementations of the algorithms were optimized for these applications. The multiplicative algebraic reconstruction technique algorithm gave the best results overall; the algebraic reconstruction technique gave the best results for very smooth objects or very noisy (20-dB signal-to-noise ratio) data. My implementations of both of these algorithms incorporate apriori knowledge of the sign of the object, its extent, and its smoothness. The smoothness of the reconstruction is enforced through the use of an appropriate object model (by use of cubic B-spline basis functions and a number of object coefficients appropriate to the object being reconstructed). The average reconstruction error was 1.7% of the maximum phantom value with the multiplicative algebraic reconstruction technique of a phantom with moderate-to-steep gradients by use of data from five viewing angles with a 30-dB signal-to-noise ratio.

  9. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  10. Denoising Message Passing for X-ray Computed Tomography Reconstruction

    CERN Document Server

    Perelli, Alessandro; Can, Ali; Davies, Mike E

    2016-01-01

    X-ray Computed Tomography (CT) reconstruction from sparse number of views is becoming a powerful way to reduce either the radiation dose or the acquisition time in CT systems but still requires a huge computational time. This paper introduces an approximate Bayesian inference framework for CT reconstruction based on a family of denoising approximate message passing (DCT-AMP) algorithms able to improve both the convergence speed and the reconstruction quality. Approximate Message Passing for Compressed Sensing has been extensively analysed for random linear measurements but there are still not clear solutions on how AMP should be modified and how it performs with real world problems. In particular to overcome the convergence issues of DCT-AMP with structured measurement matrices, we propose a disjoint preconditioned version of the algorithm tailored for both the geometric system model and the noise model. In addition the Bayesian DCT-AMP formulation allows to measure how the current estimate is close to the pr...

  11. Temporomandibular joint computed tomography: development of a direct sagittal technique

    Energy Technology Data Exchange (ETDEWEB)

    van der Kuijl, B.; Vencken, L.M.; de Bont, L.G.; Boering, G. (Univ. of Groningen, (Netherlands))

    1990-12-01

    Radiology plays an important role in the diagnosis of temporomandibular disorders. Different techniques are used with computed tomography offering simultaneous imaging of bone and soft tissues. It is therefore suited for visualization of the articular disk and may be used in patients with suspected internal derangements and other disorders of the temporomandibular joint. Previous research suggests advantages to direct sagittal scanning, which requires special positioning of the patient and a sophisticated scanning technique. This study describes the development of a new technique of direct sagittal computed tomographic imaging of the temporomandibular joint using a specially designed patient table and internal light visor positioning. No structures other than the patient's head are involved in the imaging process, and misleading artifacts from the arm or the shoulder are eliminated. The use of the scanogram allows precise correction of the condylar axis and selection of exact slice level.

  12. Positron emission tomography in cerebrovascular disease: The relationship between regional cerebral blood flow, blood volume and oxygen metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Herold, S.

    1985-03-01

    Positron emission tomography in cerebrovascular disease has demonstrated the importance of the relationship between regional cerebral blood flow and the cerebral metabolic activity. In acute stroke it has been found that within the first hours after the onset of symptoms cerebral blood flow in the affected area is more depressed than cerebral oxygen utilisation. This relative preservation of oxygen utilisation results from an increase in the oxygen extraction ratio far above its normal value. However, the oxygen extraction fraction subsequently falls in the following days indicating the transition from a situation of possibly reversible ischaemia to irreversible infarction. In patients with carotid occlusive disease an increase in the oxygen extraction ratio has been observed only in very few cases. It has been shown, however, that at an earlier stage the relationship between CBF and CBV (as CBF/CBV-ratio) provides a sensitive measure of diminished perfusion pressure which could be helpful for the selection of patients for EC-IC bypass surgery. In patients with sickle cell anaemia it has been found that oxygen delivery to the brain is maintained by an increase in cerebral blood flow, whereas the oxygen extraction ratio is not increased despite the presence of a low oxygen affinity haemoglobin. Preliminary observations in classical migraine suggest an ischaemic situation during the attack.

  13. Hemodynamic changes in a rat parietal cortex after endothelin-1-induced middle cerebral artery occlusion monitored by optical coherence tomography

    Science.gov (United States)

    Liu, Jian; Ma, Yushu; Dou, Shidan; Wang, Yi; La, Dongsheng; Liu, Jianghong; Ma, Zhenhe

    2016-07-01

    A blockage of the middle cerebral artery (MCA) on the cortical branch will seriously affect the blood supply of the cerebral cortex. Real-time monitoring of MCA hemodynamic parameters is critical for therapy and rehabilitation. Optical coherence tomography (OCT) is a powerful imaging modality that can produce not only structural images but also functional information on the tissue. We use OCT to detect hemodynamic changes after MCA branch occlusion. We injected a selected dose of endothelin-1 (ET-1) at a depth of 1 mm near the MCA and let the blood vessels follow a process first of occlusion and then of slow reperfusion as realistically as possible to simulate local cerebral ischemia. During this period, we used optical microangiography and Doppler OCT to obtain multiple hemodynamic MCA parameters. The change trend of these parameters from before to after ET-1 injection clearly reflects the dynamic regularity of the MCA. These results show the mechanism of the cerebral ischemia-reperfusion process after a transient middle cerebral artery occlusion and confirm that OCT can be used to monitor hemodynamic parameters.

  14. Computer-assisted 3D reconstruction of the terminal branches of th cerebral arteries. Pt. 2. Middle cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Gloger, S. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Gloger, A. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Vogt, H. (Dept. of Neuroanatomy, Hannover Medical School (Germany)); Kretschmann, H.J. (Dept. of Neuroanatomy, Hannover Medical School (Germany))

    1994-04-01

    We present a three-dimensional anatomical computer model of the terminal branches of the middle cerebral artery, acquired from equidistant serial anatomical slices of three brains. The reconstructions provide a clear picture from all angles of the complicated course of the terminal branches of the cerebral arteries, which can help to identify them on conventional angiography and magnetic resonance angiography. The arteries can also be matched with CT, MR or PET images to indicate the areas of extension of individual branches, allowing neuromorphological and functional correlations. (orig.)

  15. Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

    Science.gov (United States)

    Rana, Nivedita; Rawat, Dinesh; Parmar, Madan; Dhawan, Devinder Kumar; Bhati, Ashok Kumar; Mittal, Bhagwant Rai

    2015-01-01

    This study was undertaken to evaluate the effect of external metal filters on the image quality of computed tomography (CT) and single photon emission computed tomography (SPECT)/CT images. Images of Jaszack phantom filled with water and containing iodine contrast filled syringes were acquired using CT (120 kV, 2.5 mA) component of SPECT/CT system, ensuring fixation of filter on X-ray collimator. Different thickness of filters of Al and Cu (1 mm, 2 mm, 3 mm, and 4 mm) and filter combinations Cu 1 mm, Cu 2 mm, Cu 3 mm each in combination with Al (1 mm, 2 mm, 3 mm, and 4 mm), respectively, were used. All image sets were visually analyzed for streak artifacts and contrast to noise ratio (CNR) was derived. Similar acquisition was done using Philips CT quality control (QC) phantom and CNR were calculated for its lexan, perspex, and teflon inserts. Attenuation corrected SPECT/CT images of Jaszack phantom filled with 444-555 MBq (12-15 mCi) of (99m)Tc were obtained by applying attenuation correction map generated by hardened X-ray beam for different filter combination, on SPECT data. Uniformity, root mean square (rms) and contrast were calculated in all image sets. Less streak artifacts at iodine water interface were observed in images acquired using external filters as compared to those without a filter. CNR for syringes, spheres, and inserts of Philips CT QC phantom was almost similar to Al 2 mm, Al 3 mm, and without the use of filters. CNR decreased with increasing copper thickness and other filter combinations. Uniformity and rms were lower, and value of contrast was higher for SPECT/CT images when CT was acquired with Al 2 mm and 3 mm filter than for images acquired without a filter. The study suggests that for Infinia Hawkeye 4, SPECT/CT system, Al 2 mm, and 3 mm are the optimum filters for improving image quality of SPECT/CT images of Jaszack or Philips CT QC phantom keeping other parameters of CT constant.

  16. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  17. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  18. Hyperventilation-induced reduction in cerebral blood flow: Assessment by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bednarczyk, E.M.; Rutherford, W.F.; Leisure, G.P.; Munger, M.A.; Panacek, E.A.; Miraldi, F.D.; Green, J.A. (Case Western Reserve Univ. School of Medicine, Cleveland, OH (USA))

    1990-05-01

    The use of positron emission tomography (PET) has been well documented as a relatively noninvasive method of measuring cerebral blood flow (CBF), both globally and regionally. The utility of readily detecting alterations in CBF is apparent, particularly when applied to the evaluation of therapeutic interventions thought to influence CBF. We report the effects of hypocapnia, an experimental condition of known cerebral vasoconstriction, in ten normal volunteers. Subjects had brain blood flow evaluated utilizing H215O as the positron emitter before and after approximately five minutes of hyperventilation. Baseline CBF was measured as a mean +/- SD of 61.2 +/- 16.3 mL/min/100 g of tissue. Mean baseline arterial blood gas values were PaO2 107.4 +/- 14 mm Hg, PaCO2 37.7 +/- 0.89 mm Hg, and pH 7.39 (calculated from mean (H+)). Post hyperventilation, global CBF was measured as 31.1 +/- 10.8 mL/min/100 g. Mean arterial blood gas values were PaO2 141.7 +/- 21 mm Hg, PaCO2 19.7 +/- 5 mm Hg, and pH 7.63 (calculated from mean (H+)). CBF decreased by a mean of 49.5 +/- 11 percent. Data analysis using the Student's t-test showed a significant change over baseline in PaCO2 (p less than 0.001) and CBF (p less than 0.001), in the hyperventilated state. Correlations were noted between the decrease in CBF and change in PaCO2 (r = 0.81) as well as between hyperventilation PaCO2 and the change in CBF (r = 0.97). We conclude that, as measured by PET, CBF decreases significantly during a state of artificial hyperventilation to a degree consistent with results seen using other methods. PET appears to be a valuable tool in the assessment of interventions that could influence CBF.

  19. Cranial computer assisted tomography and electroencephalography in children with acute lymphocytic leukemia : a longitudinal study : Computertomografie van de schedel en electroencephalografisch onderzoek bij kinderen met een acute lymfatische leukemie. Een longitudinale studie

    NARCIS (Netherlands)

    K. Hählen (Karel)

    1990-01-01

    textabstractThis longitudinal study was initiated in order to examine the nature and sequence of structural and functional cerebral abnormalities in children with acute lymphocytic leukemia (ALL). For this purpose computer assisted tomography scans of the brain ( CT scans ) and electroencephalograms

  20. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  1. Virtual positron emission tomography/computed tomography-bronchoscopy: possibilities, advantages and limitations of clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Seemann, Marcus D. [University of Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Schaefer, Juergen F. [Eberhard-Karls University, Department of Diagnostic Radiology, Tuebingen (Germany); Englmeier, Karl-Hans [Institute of Medical Informatics, GSF-National Research Center for Environment and Health, Neuherberg (Germany)

    2007-03-15

    The aim of this study was to demonstrate the possibilities, advantages and limitations of virtual bronchoscopy using data sets from positron emission tomography (PET) and computed tomography (CT). Twelve consecutive patients with lung cancer underwent PET/CT. PET was performed with F-18-labelled 2-[fluorine-18]-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG). The tracheobronchial system was segmented with a volume-growing algorithm, using the CT data sets, and visualized with a shaded-surface rendering method. The primary tumours and the lymph node metastases were segmented for virtual CT-bronchoscopy using the CT data set and for virtual PET/CT-bronchoscopy using the PET/CT data set. Virtual CT-bronchoscopy using the low-dose or diagnostic CT facilitates the detection of anatomical/morphological structure changes of the tracheobronchial system. Virtual PET/CT-bronchoscopy was superior to virtual CT-bronchoscopy in the detection of lymph node metastases (P=0.001), because it uses the CT information and the molecular/metabolic information from PET. Virtual PET/CT-bronchoscopy with a transparent colour-coded shaded-surface rendering model is expected to improve the diagnostic accuracy of identification and characterization of malignancies, assessment of tumour staging, differentiation of viable tumour tissue from atelectases and scars, verification of infections, evaluation of therapeutic response and detection of an early stage of recurrence that is not detectable or is misjudged in comparison with virtual CT-bronchoscopy. (orig.)

  2. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  3. Positron emission tomography/computer tomography in guidance of extrahepatic hepatocellular carcinoma metastasis management

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.

  4. Computed tomography image reconstruction from only two projections

    CERN Document Server

    Mohammad-Djafari, Ali

    2007-01-01

    English: This paper concerns the image reconstruction from a few projections in Computed Tomography (CT). The main objective of this paper is to show that the problem is so ill posed that no classical method, such as analytical methods based on inverse Radon transform, nor the algebraic methods such as Least squares (LS) or regularization theory can give satisfactory result. As an example, we consider in detail the case of image reconstruction from two horizontal and vertical projections. We then show how a particular composite Markov modeling and the Bayesian estimation framework can possibly propose satisfactory solutions to the problem. For demonstration and educational purpose a set of Matlab programs are given for a live presentation of the results. ----- French: Ce travail, \\`a but p\\'edagogique, pr\\'esente le probl\\`eme inverse de la reconstruction d'image en tomographie X lorsque le nombre des projections est tr\\`es limit\\'e. voir le texte en Anglais et en Fran\\c{c}ais.

  5. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  6. Simulation of emission tomography using grid middleware for distributed computing.

    Science.gov (United States)

    Thomason, M G; Longton, R F; Gregor, J; Smith, G T; Hutson, R K

    2004-09-01

    SimSET is Monte Carlo simulation software for emission tomography. This paper describes a simple but effective scheme for parallel execution of SimSET using NetSolve, a client-server system for distributed computation. NetSolve (version 1.4.1) is "grid middleware" which enables a user (the client) to run specific computations remotely and simultaneously on a grid of networked computers (the servers). Since the servers do not have to be identical machines, computation may take place in a heterogeneous environment. To take advantage of diversity in machines and their workloads, a client-side scheduler was implemented for the Monte Carlo simulation. The scheduler partitions the total decay events by taking into account the inherent compute-speeds and recent average workloads, i.e., the scheduler assigns more decay events to processors expected to give faster service and fewer decay events to those expected to give slower service. When compute-speeds and sustained workloads are taken into account, the speed-up is essentially linear in the number of equivalent "maximum-service" processors. One modification in the SimSET code (version 2.6.2.3) was made to ensure that the total number of decay events specified by the user is maintained in the distributed simulation. No other modifications in the standard SimSET code were made. Each processor runs complete SimSET code for its assignment of decay events, independently of others running simultaneously. Empirical results are reported for simulation of a clinical-quality lung perfusion study.

  7. Depressed cerebral oxygen metabolism in patients with chronic renal failure. A positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Hirakata, Hideki; Kanai, Hidetoshi; Nakane, Hiroshi; Fujii, Ken-ichiro; Hirakata, Eriko; Ibayashi, Setsuro; Kuwabara, Yasuo; Deenitchna, S.S.; Fujishima, Masatoshi [Kyushu Univ., Fukuoka (Japan). Graduate School of Medical Sciences

    2001-07-01

    In order to elucidate brain oxygen metabolism in uremic patients, the regional cerebral blood flow (rCBF), oxygen extraction (rOEF) and oxygen metabolism (rCMRO{sub 2}) were measured by positron emission tomography (PET) in both 10 hemodialysis patients (HD: male [m]/female [f]=2/8, age of 49{+-}3 [SEM] years old, HD duration of 113{+-}26 months) and 13 pre-dialysis renal failure patients (CRF: m/f=10/3, age of 61{+-}2 years old, serum creatinine (SCr) of 6.3{+-}1.0 mg/dl). Data were compared with 20 non-uremic subjects (Control: m/f=7/13, age of 62{+-}2 years old, SCr of 0.9{+-}0.1 mg/dl). They had no neurological abnormalities, congestive heart failure, history of cerebrovascular accident, diabetes mellitus, or symptomatic brain lesion on magnetic resonance imaging. The age of HD was significantly younger than the other groups (p<0.02) and the hemoglobin (Hb) levels in both HD (10.5{+-}0.5 g/dl) and CRF (9.8{+-}0.9) were significantly lower than that in Control (13.3{+-}0.3) (p<0.02). In the hemisphere, rCMRO{sub 2} in both HD (1.82{+-}0.10 ml/min/100 g) and CRF (1.95{+-}0.09) showed significantly lower values as compared to Control (2.23{+-}0.05) (p<0.01, respectively). Hemispheric rCBF in HD (35.6{+-}2.1 ml/100 g/min) and in CRF (36.1{+-}2.1) were not different from that in Control (31.8{+-}1.4). Hemispheric rOEF in CRF (45.7{+-}1.6%) was significantly higher than that in Control (40.5{+-}1.2%) (p<0.02), but that in HD (43.7{+-}1.9%) did not increase significantly. These tendencies were similar in all regions of interest, especially in the cerebral cortices, but not in the cerebellum. All PET parameters in the frontal cortices tended to show the lowest value in renal failure patients. For all HD patients, rCBF in both the frontal cortex and the white matter correlated inversely with HD duration (frontal cortex: r=-0.649, p<0.05; white matter: r=-0.706, p<0.02). Based on these data, it is concluded that brain oxygen metabolism is depressed in renal failure

  8. Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography

    Institute of Scientific and Technical Information of China (English)

    程任翔; 陶超; 刘晓峻

    2015-01-01

    The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo-geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to-mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.

  9. Survey of patient dose in computed tomography in Syria 2009.

    Science.gov (United States)

    Kharita, M H; Khazzam, S

    2010-09-01

    The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the International Atomic Energy Agency in different regions of the world covering Asia, Africa and Eastern Europe. The dose quantities covered are CT dose index (CTDI(w)), dose-length product (DLP), effective dose (E) and collective dose. It was found that most CTDI(w) and DLP values were similar to the European reference levels and in line with the results of similar surveys in the world. The results were in good agreement with the UNSCEAR Report 2007. This study concluded a recommendation for national diagnostic reference level for the most common CT protocols in Syria. The results can be used as a base for future optimisation studies in the country.

  10. Software innovations in computed tomography for structural heart disease interventions.

    Science.gov (United States)

    Hell, Michaela; Marwan, Mohamed; Gaede, Luise; Achenbach, Stephan

    2016-05-17

    Computed tomography (CT) provides high, isotropic spatial resolution and has become firmly established in pre-procedural imaging for structural heart disease interventions. It allows determination of the exact dimensions of the target structure, provides information regarding the access route and permits identification of fluoroscopic projection angles to provide optimal visualisation for device placement. Several software solutions are available and have been systematically evaluated in the context of transcatheter aortic valve implantation (TAVI). The use of software products to perform automated measurements can be useful, especially when the experience and expertise regarding evaluation of CT in the context of structural heart disease are limited. In scientific studies, software has been demonstrated to provide accurate support for annulus sizing and prosthesis selection, to aid in reliably identifying patients in whom a transfemoral access may be problematic, and to suggest suitable angulations for fluoroscopic imaging to achieve an orthogonal view onto the aortic valve during implantation.

  11. Application of cone beam computed tomography in facial imaging science

    Institute of Scientific and Technical Information of China (English)

    Zacharias Fourie; Janalt Damstra; Yijin Ren

    2012-01-01

    The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years.Traditional 2D imaging has gradually being replaced by 3D images in different disciplines,particularly in the fields of orthodontics,maxillofacial surgery,plastic and reconstructive surgery,neurosurgery and forensic sciences.In most cases,3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton.The aim of this study was to review the types of imaging methods used for facial imaging.It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ.Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly importanl role in orthodontics and orthognathic surgery,special emphasis should be placed on discussing CBCT applications in facial evaluations.

  12. Complicated cholecystitis: the complementary roles of sonography and computed tomography.

    Science.gov (United States)

    Charalel, Resmi A; Jeffrey, R Brooke; Shin, Lewis K

    2011-09-01

    Acute cholecystitis is a common cause of abdominal pain in the Western world. Unless treated promptly, patients with acute cholecystitis may develop complications such as gangrenous, perforated, or emphysematous cholecystitis. Because of the increased morbidity and mortality of complicated cholecystitis, early diagnosis and treatment are essential for optimal patient care. Nevertheless, complicated cholecystitis may pose significant challenges with cross-sectional imaging, including sonography and computed tomography (CT). Interpreting radiologists should be familiar with the spectrum of sonographic findings seen with complicated cholecystitis and as well as understand the complementary role of CT. Worrisome imaging findings for complicated cholecystitis include intraluminal findings (sloughed mucosa, hemorrhage, abnormal gas), gallbladder wall abnormalities (striations, asymmetric wall thickening, abnormal gas, loss of sonoreflectivity and contrast enhancement), and pericholecystic changes (echogenic fat, pericholecystic fluid, abscess formation). Finally, diagnosis of complicated cholecystitis by sonography and CT can guide alternative treatments including minimally invasive percutaneous and endoscopic options.

  13. Computed tomography dose optimisation in cystic fibrosis: A review.

    LENUS (Irish Health Repository)

    Ferris, Helena

    2016-04-28

    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  14. Dose reduction with adaptive bolus chasing computed tomography angiography.

    Science.gov (United States)

    Cai, Zhijun; Bai, Er-Wei; Wang, Ge; Sharafuddin, Melhem J; Abada, Hicham T

    2010-01-01

    Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%.

  15. Building a 3D Computed Tomography Scanner From Surplus Parts.

    Science.gov (United States)

    Haidekker, Mark A

    2014-01-01

    Computed tomography (CT) scanners are expensive imaging devices, often out of reach for small research groups. Designing and building a CT scanner from modular components is possible, and this article demonstrates that realization of a CT scanner from components is surprisingly easy. However, the high costs of a modular X-ray source and detector limit the overall cost savings. In this article, the possibility of building a CT scanner with available surplus X-ray parts is discussed, and a practical device is described that incurred costs of less than $16,000. The image quality of this device is comparable with commercial devices. The disadvantage is that design constraints imposed by the available components lead to slow scan speeds and a resolution of 0.5 mm. Despite these limitations, a device such as this is attractive for imaging studies in the biological and biomedical sciences, as well as for advancing CT technology itself.

  16. Cholecystocolonic fistula mimicking acute cholecystitis diagnosed unequivocally by computed tomography.

    Science.gov (United States)

    Chick, Jeffrey Forris Beecham; Chauhan, Nikunj Rashmikant; Paulson, Vera Ashley; Adduci, Alexander J

    2013-12-01

    Cholecystocolonic fistula is an uncommon potential complication of cholecystitis found intraoperatively in 0.06-0.14 % of patients undergoing cholecystectomy and 0.1-0.5 % of autopsy series. Although cholecystocolonic fistula is the second most common cholecystoenteric fistula, second only to cholecystoduodenal fistula, it is diagnosed preoperatively in only 7.9 % of patients. Failure to preoperatively diagnose cholecystocolonic fistula places surgeons in precarious positions, as they may be forced to convert a seemingly routine cholecystectomy to a more sophisticated procedure coupled with adhesiolysis, colonic suturing, or colonic resection. We report a young patient who presented to the emergency department with complaints indicative of acute cholecystitis; however, preoperative ultrasound was suggestive of a cholecystoenteric fistula. Computed tomography and pathology were pathognomonic with clear visualization of the cholecystocolonic fistulous tract.

  17. Systematic Errors in Dimensional X-ray Computed Tomography

    DEFF Research Database (Denmark)

    of the measurement. As a consequence, there is a high risk that on the basis of defective measurement results, a manufactured product is wrongly rejected in conformance testing. According to guidelines and standards, systematic error influences on a final measurand must be avoided or at least known so......A result of a measurement is usually affected by a measurement error which cannot be avoided in practice. Particularly in production metrology, systematic errors from, e.g, temperature influences, drift effects, etc., may lead to high measurement deviation in respect to the true value...... that it is possible to compensate them. In dimensional X-ray computed tomography (CT), many physical quantities influence the final result. However, it is important to know which factors in CT measurements potentially lead to systematic errors. In this talk, typical error sources in dimensional X-ray CT are discussed...

  18. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  19. Computed tomography of the retroperitoneum in patients with femoral neuropathy.

    Science.gov (United States)

    Eustace, S; McCarthy, C; O'Byrne, J; Breatnach, E; Fitzgerald, E

    1994-08-01

    The authors illustrate the value of computed tomography (CT) of the retroperitoneum in patients presenting with femoral nerve signs. They describe 28 such patients, examined at a tertiary-care hospital between June 1990 and January 1993, in whom CT of the retroperitoneum contributed significantly to the diagnosis. The patients, 19 males and 9 females, ranged in age from 11 to 81 years. CT showed disease of the psoas compartment in 17 cases; the condition was due to a malignant lesion in 9 cases and was secondary to infection in 5 and to other causes in 3. Disease of the iliacus compartment was shown in 11 cases; it was due to a malignant lesion in 6 cases and was secondary to hemorrhage in 2, to infection in 1 and to a bursa in 1. The diagnostic features of the diseases encountered are discussed, and the importance of performing CT early is stressed.

  20. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended.

  1. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-08-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  2. Non-diffusing photochromic gel for optical computed tomography phantoms

    Science.gov (United States)

    Jordan, K.

    2013-06-01

    This study examines photochromic response in radiation sensitive hydrogels. Genipin, crosslinked, gelatin gel can support high resolution images because the chromophores do not diffuse. A low power, 633 nm He-Ne laser was used to write lines into the gels by a photobleaching reaction. Optical cone-beam computed tomography (CBCT) scans mapped the high resolution images in 3D with 0.25 mm voxel resolution. A straight line was written into a deformed gel and then readout in its relaxed, initial shape. The curved, photo-bleached line demonstrated deformable 3D dosimetry is possible with this system to the balloon edge. High resolution, photochromic images provide key information for characterizing optical CT scanners and 3D dosimeters. Many, ionizing radiation, dosimeter materials demonstrate either a photochromic or photothermal response, allowing this approach to be widely used in quantitative 3D scanning.

  3. Meningitis tuberculosa: Clinical findings and results of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Trautmann, M.; Loddenkemper, R.; Hoffmann, H.G.

    1982-10-01

    Guided by 9 own observations between 1977 and 1981, new diagnostic facilities in tuberculous meningitis are discussed. For differentiation from viral meningitis, measurement of CSF lactic acid concentration in addition to that of CSF glucose has proved to be of value in recent years. In accordance with the literature, two cases of this series which were examined for CSF lactic acid concentration showed markedly elevated levels of 8,4 rsp. 10,4 mmol/l. In contrast to this, in viral meningitis usually values of less than 3.5 mmol/l are found. Additionally, the presence of hypochlor- and hyponatremia, which could be demonstrated in 6 of our 9 patients, may raise the suspicion of tuberculous etiology. In the series presented, cranial computed tomography was of greatest diagnostic value, enabling the diagnosis of hydrocephalus internus in 5, and basal arachnoiditis in 2 cases.

  4. Dacryocystography using computed tomography prior to external dacryocystorhinostomy

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ikue; Chijiiwa, Taeko [National Kyushu Medical Center, Fukuoka (Japan)

    2002-01-01

    We performed dacryocystography using computed tomography in 47 eyes of 45 patients of chronic dacryocystitis prior to external dacryocystorhinostomy. The radiopaque agent was injected into the lower canaliculus. The findings were useful in estimating the thickness of the bony wall of lacrimal fossa. The ethmoidal sinus was located adjacent and nasal to the lacrimal fossa in 11 eyes (23%). Care was needed in these cases not to create an anastomosis between the lacrimal sac and the ethmoidal sinus. The contrast medium was located in the nasolacrimal duct in 14 eyes (30%), suggesting that the obstruction was located in the lower nasolacrimal duct. Intraoperative irrigation-aspiration appeared to be indicated in these cases. Traumatic bony fracture with hypertrophy was present in one case, suggesting that nasolacrimal obstruction may be induced by facial trauma. (author)

  5. Initial results of finger imaging using Photoacoustic Computed Tomography

    CERN Document Server

    van Es, Peter; Moens, Hein J Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-01-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $\\mu$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential marke...

  6. Quality Criteria Implementation for Brain Computed Tomography Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Calzado, A.; Rodriguez, R.; Munoz, A

    1998-07-01

    The main aim of this study was to implement the quality criteria proposed by the European Commission for brain computed tomography (CT) examinations. The proposed criteria were evaluated for 102 brain CT examinations, with a special emphasis on the diagnostic and radiation dose requirements. The examinations were selected at random from brain examinations performed over a period of a month at eight scanners of the CT Pace range. Achievement of image criteria was evaluated by two independent observers. The most important preliminary findings concerning image criteria fulfilment or lack of it and disagreements between observers are presented and discussed. The mean values of the proposed dosimetric quantities are compared to the reference values. The examinations performed with and without injection of a contrast agent are also analysed in relation to dosimetric quantities and criteria fulfilment. (author)

  7. Gamma-ray computed tomography to characterize soil surface sealing

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.Luiz F. E-mail: lfpires@cena.usp.br; Macedo, Jose R. de; Souza, Manoel D. de; Bacchi, Osny O.S.; Reichardt, Klaus

    2002-09-01

    The application of sewage sludge as a fertilizer on soils may cause compacted surface layers (surface sealing), which can promote changes on soil physical properties. The objective of this work was to study the use of gamma-ray computed tomography, as a diagnostic tool for the evaluation of this sealing process through the measurement of soil bulk density distribution of the soil surface layer of samples subjected to sewage sludge application. Tomographic images were taken with a first generation tomograph with a resolution of 1 mm. The image analysis opened the possibility to obtain soil bulk density profiles and average soil bulk densities of the surface layer and to detect the presence of soil surface sealing. The sealing crust thickness was estimated to be in the range of 2-4 mm.

  8. Inspection of a Medieval Wood Sculpture Using Computer Tomography

    Science.gov (United States)

    Kapitany, K.; Somogyi, A.; Barsi, A.

    2016-06-01

    Computer tomography (CT) is an excellent technique for obtaining accurate 3D information about the human body. It allows to visualize the organs, bones and blood vessels, furthermore it enables to diagnose anomalies and diseases. Its spatial reconstruction capability supports other interesting applications, such as inspecting different, even valuable objects like ancient sculptures. Current paper presents a methodology of evaluating CT and video imagery through the example of investigating a wood Madonna with infant Jesus sculpture from the 14th century. The developed techniques extract the outer boundary of the statue, which has been triangulated to derive the surface model. The interior of the sculpture has also been revealed: the iron bolts and rivets as well as the woodworm holes can be mapped. By merging the interior and outer data (geometry and texture) interesting visualizations (perspective views, sections etc.) have been created.

  9. The possibilities of computer tomography in paecilomycosis of lungs

    Directory of Open Access Journals (Sweden)

    Abdusalom Ashurov

    2010-09-01

    Full Text Available We have analyzed computed tomography (CT results of chest in 56 patients with lung injures caused by paecilomycosis fungus at the age from 17 to 59 years. In our investigations, the perverted lung pattern due to pathology of interstitial tissue was observed in 52 (93% patients of 56 (with chronic bronchitis - 100%, exogenous-allergic alveolitis - 93%, recurrent pneumonia - 100% and with bronchial asthma - 80%. Analysis showed that CT provides wide opportunities in visualization of all spectrum of symptoms in lung tissue injury and could allow to increase the accuracy of determining the character and degree of injury, and also it could allow to determine localization and spreading of the pathological process.

  10. Fossa navicularis magna detection on cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Ali Z. [Dept. of Oral and Maxillofacial Medicine and Diagnostic Sciences, School of Dental Medicine, Case Western Reserve University, Cleveland(United States); Mupparapu, Mel [Div. of Radiology, University of Pennsylvania School of Dental Medicine, Philadelphia (United States)

    2016-03-15

    Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed.

  11. Lung cancer screening: Computed tomography or chest radiographs?

    Institute of Scientific and Technical Information of China (English)

    Edwin; JR; van; Beek; Saeed; Mirsadraee; John; T; Murchison

    2015-01-01

    Worldwide, lung cancer is the leading cause of mortalitydue to malignancy. The vast majority of cases of lung cancer are smoking related and the most effective way of reducing lung cancer incidence and mortality is by smoking cessation. In the Western world, smoking cessation policies have met with limited success. The other major means of reducing lung cancer deaths is to diagnose cases at an earlier more treatable stage employing screening programmes using chest radiographs or low dose computed tomography. In many countries smoking is still on the increase, and the sheer scale of the problem limits the affordability of such screening programmes. This short review article will evaluate the current evidence and potential areas of research which may benefit policy making across the world.

  12. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  13. Cysticercosis of the brain. The value of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almeida-Pinto, J.; Veiga-Pires, J.A.; Stocker, A.; Coelho, T.; Monteiro, L.

    Incidence and radiologic findings of neurocysticercosis were investigated in a series of 23 800 consecutive head examinations using computed tomography (CT). The condition was diagnosed in 168 case (0.7%). The parenchymatous form was the most common presentation (96.3%), while the meningeal form corresponded to only 11.9% of cases. These two forms coexisted in some cases. These findings reversed the knowledge on the condition based on conventional radiography. The different CT appearances in the brain are described and a new radiologic protocol for the CT evaluation of the condition is advocated, which includes a follow-up after a trial cure with Praziquantel in the presence of cysts not associated with suggestive brain calcifications. CT were more sensitive than conventional radiography in the differentiation between dead and living larvae, thus having an impact on the therapeutic management of the patients.

  14. Micro-computed tomography for small animal imaging: Technological details

    Institute of Scientific and Technical Information of China (English)

    Hao Li; Hui Zhang; Zhiwei Tang; Guangshu Hu

    2008-01-01

    The high-resolution micro-computed tomography(micro-CT)system has now become an important tool for biological research.The micro-CT system enables a non-invasive inspection to screen anatomical changes in small animals.The promising advantages include high-spatial resolution,high sensitivity to bone and lung,short scan time and cost-effectiveness.The dose received by the small animal might be a critical concern in the research.In this article,the choice of the components,fundamental physical problems,the image reconstruction algorithm and the representative applications of micro-CT are summarized.Some results from our research group are also presented to show high-resolution images obtained by the micro-CT system.

  15. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-07-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  16. Low-dose computed tomography to diagnose fetal bone dysplasias.

    Science.gov (United States)

    Montoya Filardi, A; Guasp Vizcaíno, M; Gómez Fernández-Montes, J; Llorens Salvador, R

    We present a case of cleidocranial dysplasia diagnosed by low-dose fetal computed tomography (CT) in the 25th week of gestation. Severe bone dysplasia was suspected because of the fetus' low percentile in long bones length and the appearance of craniosynostosis on sonography. CT found no abnormalities incompatible with life. The effective dose was 5 mSv, within the recommended range for this type of examination. Low-dose fetal CT is a new technique that makes precision study of the bony structures possible from the second trimester of pregnancy. In Spain, abortion is legal even after the 22nd week of gestation in cases of severe fetal malformations. Therefore, in cases in which severe bone dysplasia is suspected, radiologists must know the strategies for reducing the dose of radiation while maintaining sufficient diagnostic quality, and they must also know which bony structures to evaluate.

  17. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Atzingen, Augusto Castelli von [Clinical Radiology, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2012-05-15

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  18. Three-dimensional computed tomography of the acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S.; Muner, G.; Pozzi Mucelli, F.; Pozzi Mucelli, M.; Marotti, F.; Dalla Palma, L.

    1986-08-01

    Acetabular fractures represent a complex variety that are classified in different types. Conventional radiology is often inadequate to demonstrate and classify the fractures. Computed tomography (CT) has already been shown to be superior in this field. A further advantage of CT is represented by the recent availability of three-dimensional (3D) images that are realized from axial CT scans by means of a new software. The Authors report the applications of this new software to the study of the normal acetabulum and in patients with fractures. 3D images allows an effective demonstration of the fracture, its irradiation and the dislocation of bone fragments. The information is contained in one or few images rather than many axial images. Therefore the role of 3D images may be considered complementary to axial CT scans.

  19. Malignant uveal melanoma and similar lesions studied by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mafee, M.F.; Peyman, G.A.; McKusick, M.A.

    1985-08-01

    Forty-four patients with intraocular disease were studied by computed tomography (CT); in 19 cases malignant uveal melanoma was considered the likely diagnosis. CT proved to be accurate in determining the location and size of uveal melanomas, demonstrating scleral invasion, and differentiating melanoma from choroidal detachment or angioma, toxocariasis, and senile macular degeneration. On CT, uveal melanomas appeared as hyperdense lesions with slight to moderate contrast enhancement. Tumors thinner than 2 mm could not be seen. Using dynamic CT, the authors noted moderate peak amplitude, normal or delayed tissue transit time, and persistently elevated washout phase (downslope), indicating increased permeability as the result of an impaired tumor blood barrier. Histological types of uveal melanoma could not be differentiated on the basis of circulatory patterns. Dynamic CT may be useful in distinguishing uveal melanoma from choroidal hemangioma or hematoma.

  20. Recent Developments in Computed Tomography for Urolithiasis: Diagnosis and Characterization

    Directory of Open Access Journals (Sweden)

    P. D. Mc Laughlin

    2012-01-01

    Full Text Available Objective. To critically evaluate the current literature in an effort to establish the current role of radiologic imaging, advances in computed tomography (CT and standard film radiography in the diagnosis, and characterization of urinary tract calculi. Conclusion. CT has a valuable role when utilized prudently during surveillance of patients following endourological therapy. In this paper, we outline the basic principles relating to the effects of exposure to ionizing radiation as a result of CT scanning. We discuss the current developments in low-dose CT technology, which have resulted in significant reductions in CT radiation doses (to approximately one-third of what they were a decade ago while preserving image quality. Finally, we will discuss an important recent development now commercially available on the latest generation of CT scanners, namely, dual energy imaging, which is showing promise in urinary tract imaging as a means of characterizing the composition of urinary tract calculi.

  1. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography improves the diagnostic accuracy of osteoid osteoma

    Science.gov (United States)

    Squier, Samuel Brian; Lewis, Jacob Ian; Accurso, Joseph Matthew; Jain, Manoj Kumar

    2016-01-01

    We present a case of a 17-year-old football player who had previously received multiple facet joint injections for presumed secondary osteoarthritis. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography imaging of the cervical spine demonstrated focal increased radiopharmaceutical activity in the right C2 lamina, which was associated with an osteolytic lesion with a central irregular sclerotic nidus. Surgical pathology confirmed an osteoid osteoma. PMID:27833319

  2. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome.

    Science.gov (United States)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome.

  3. Multiscale and multimodality computed tomography for cortical bone analysis

    Science.gov (United States)

    Ostertag, A.; Peyrin, F.; Gouttenoire, P. J.; Laredo, J. D.; DeVernejoul, M. C.; Cohen Solal, M.; Chappard, C.

    2016-12-01

    In clinical studies, high resolution peripheral quantitative computed tomography (HR-pQCT) is used to separately evaluate cortical bone and trabecular bone with an isotropic voxel of 82 µm3, and typical cortical parameters are cortical density (D.comp), thickness (Ct.Th), and porosity (Ct.Po). In vitro, micro-computed tomography (micro-CT) is used to explore the internal cortical bone micro-structure with isotropic voxels and high resolution synchrotron radiation (SR); micro-CT is considered the ‘gold standard’. In 16 tibias and 8 femurs, HR-pQCT measurements were compared to conventional micro-CT measurements. To test modality effects, conventional micro-CT measurements were compared to SR micro-CT measurements at 7.5 µm3 SR micro-CT measurements were also tested at different voxel sizes for the femurs, specifically, 7.5 µm3 versus 2.8 µm3. D.comp (r  =  -0.88, p  images provided consistent results compared to those obtained using conventional micro-CT at the distal tibia. D.comp was highly correlated to Po.V/TV because it considers both the micro-porosity (Haversian systems) and macro-porosity (resorption lacunae) of cortical bone. The complexity of canal organization, (including shape, connectivity, and surface) are not fully considered in conventional micro-CT in relation to beam hardening and cone beam reconstruction artifacts. With the exception of Po.V/TV measurements, morphological and topological measurements depend on the characteristics of the x-ray beam, and to a lesser extent, on image resolution.

  4. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  5. Actinomycosis involving the liver. Computed tomography/ultrasound correlation.

    Science.gov (United States)

    Sheth, S; Fishman, E K; Sanders, R

    1987-06-01

    The clinical profile of pelvic actinomycosis, which is being recognized with increased frequency in IUD users, can be misleading in such patients and lead to dangerous delays in diagnosis. The authors present a case in which an IUD user initially sought medical attention for multiple liver abscesses secondary to spread from unsuspected ovarian actinomycosis. The 43-year-old patient, who was admitted with right upper quadrant pain and fever, had a 15-year history of IUD use, although the device had been removed 1 year prior to admission for apparent infection in the left ovary. Ultrasound revealed mixed cystic and solid liver lesions as well as a complex subcapsular fluid collection. A solid left adnexal mass was demonstrated in the pelvis. Computed tomography scan indicated extension of 1 of the complex cystic liver lesions through the liver capsule and into the abdominal wall. Needle aspirations of the liver lesions yielded thick pus that was later identified as Actinomyces israelii. Actinomycosis was evident in the ovarian lesion. Colonization of the vagina and uterus by actinomycosis has been reported by 1.6-5.3% of IUD users, and the risk appears to increase when the same IUD is used for a prolonged time period. In this case, neither the computed tomography scan nor ultrasound suggested an inflammatory process of the left ovary. Aspiration of a liver lesion under ultrasound guidance was necessary for the correct diagnosis. Since actinomycosis has the potential to spread to extrapelvic organs such as the peritoneum, liver, and brain, early diagnosis is essential.

  6. Centre of Rotation Determination Using Projection Data in X-ray Micro Computed Tomography

    OpenAIRE

    Olander, Birger

    1994-01-01

    There are several methods available to determine the Centre Of Rotation, COR, and align detectors and X-ray focus to COR in X-ray computed tomography. Some methods use narrow rods/needles or specially made alignment objects or phantoms. In X-ray Micro Computed Tomography (or Computerized Micro Tomography), μCT (CMT), methods using sample projection data for COR measurements are preferred since the replacement of alignment objects with samples often displace translation stages and make the ali...

  7. Artifacts in computed tomography scanning of moving objects.

    Science.gov (United States)

    Chen, George T Y; Kung, Jong H; Beaudette, Kevin P

    2004-01-01

    Target volumes in the thorax and abdomen are commonly computed tomography (CT) scanned during light respiration. In this article, we analyze the distortions introduced in helical scanning of moving objects. Objects of known geometry are placed on a moving sled and scanned in a multirow helical CT scanner. The motion of the sled approximates the magnitude and velocity of organ movement in patients during light respiration (amplitude 1 cm, period 4 seconds). Scans of the phantom are obtained in high speed mode at incremental phases of respiration, and the resulting images are compared with scans obtained when the phantom is static. Computer simulations of the scan process are also performed to interpret the results and extend the analysis to a greater range of parameters in scanning, motion, and object size. Resulting scans show that spherical test objects can be shortened by as much as 2 cm or twice the periodic motion amplitude. Object shape was significantly distorted, and the geometric center of the object was displaced by as much as +/-0.8 cm. Computer simulation results qualitatively agree with the experimentally observed phantom images. These simulations predict that the effect is clearly observable even if the amplitude is decreased to 0.5 cm. Implications of scanning moving objects on treatment planning are discussed.

  8. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  9. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values

    DEFF Research Database (Denmark)

    Østergaard, Leif; Smith, D F; Vestergaard-Poulsen, Peter;

    1998-01-01

    The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water (H215O) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo......- and hypercapnic conditions. After dose normalization and introduction of an empirical constant phi Gd, absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the H215O-PET protocol. Magnetic resonance imaging cerebral...... blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C15O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small...

  10. Multi-dimensional visualization of coronary aberrancies using multi detector computed tomography

    NARCIS (Netherlands)

    van Ooijen, P; Dorgelo, J; Tukker, W; Willemsen, H; Oudkerk, M; Lewis, BS; Halon, DA; Flugelman, MY; Gensini, GF

    2003-01-01

    The purpose of this study was to evaluate the usefulness of three and four dimensional visualization of multi detector computed tomography datasets for the evaluation of coronary aberrancies. Multi detector computed tomography (MDCT) datasets were obtained in thirteen patients following a standard p

  11. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  12. Just Scan It!-Weapon Reconstruction in Computed Tomography on Historical and Current Swiss Military Guns.

    Science.gov (United States)

    Franckenberg, Sabine; Binder, Thomas; Bolliger, Stephan; Thali, Michael J; Ross, Steffen G

    2016-09-01

    Cross-sectional imaging, such as computed tomography, has been increasingly implemented in both historic and recent postmortem forensic investigations. It aids in determining cause and manner of death as well as in correlating injuries to possible weapons. This study illuminates the feasibility of reconstructing guns in computed tomography and gives a distinct overview of historic and recent Swiss Army guns.

  13. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Conway, J.J.; Poznanski, A.K.; Tachdjian, M.O.; Dias, L.S.; Kelikian, A.S.

    1985-03-01

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material.

  14. Application of single-photon emission computed tomography in modified constraint-induced movement therapy to improve limb motor function in senile cerebral infarction patients%单光子发射计算机断层显像在改良强制性运动疗法治疗老年脑梗死患者肢体运动功能的应用

    Institute of Scientific and Technical Information of China (English)

    王文清; 张欣; 李艳双; 张静; 毕胜; 瓮长水

    2011-01-01

    目的 采用单光子发射计算机断层显像(SPECT)局部脑血流(rCBF)半定量分析法,观察改良强制性运动疗法(mCIMT)对老年脑梗死偏瘫患者肢体运动功能的康复疗效.方法 12例符合入选标准的患者,男性7例,女性5例,年龄61~79(67.9±6.5)岁,病程21~77(42.7±13.6)d.进行8周的改良强制性运动疗法治疗,不限制健侧上、下肢活动,每天保持4 h的患侧上、下肢训练,其中上肢1 h,下肢3 h.在治疗前后分别进行简易手功能检查法(STEF)、10 m最大步行速度(MWS)和大脑皮质缺血灶rCBF评估.结果 治疗后STEF患侧评分为76.33±17.13(t=-6.09),STEF健侧评分为86.25 ±16.84(t=-5.86);MWS评分为6.78±3.72(t=4.88);缺血区放射性计数评分为-10.12 ± 7.25(t=5.33),明显优于治疗前,差异有统计学意义(均P<0.05).结论 使用SPECT技术观察发现,改良强制性运动疗法明显提高老年脑梗死患者肢体运动功能,证明这种变化与大脑可塑性改变相关联,推测可能与大脑皮质rCBF重新分配有关.%Objective To observe the correlation of brain functional reorganization and motor functional restoration with application of single-photon emission computed tomography (SPECT) and regional cerebral blood flow ( rCBF) in modified constraint-induced movement therapy ( mCIMT) in cerebral infarction patients with hemiplegia.Methods Twelve patients with cerebral infarction with hemiplegia (7 males and 5 females, aged 62-75 ( 67.9 ± 6.5) years) were treated with mCIMT for eight weeks.No movement restriction was applied to the limbs at the intact sides.The affected sides exercised 4 h per day with 1 h on the upper limbs and 3 h on the lower limbs.At the same time, semi-quantitative analysis method of analyzing SPECT and rCBF was used to record changes in brain.Simple test for evaluating hand function (STEF), 10 m maximum walking speed ( MWS) , rCBF changes in the cerebral cortex ischemic lesion were respectively assessed in the

  15. Value of computer tomography and sonography in the investigation of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L. Braun, G.; Buurman, R.; Scherer, K. (Bonn Univ. (Germany, F.R.). Radiologische Klinik; Hamburg Univ. (Germany, F.R.). Radiologische Klinik und Strahleninstitut; Koeln Univ. (Germany, F.R.). Radiologisches Inst. und Poliklinik)

    1980-05-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography.

  16. Comparison of Adsorbed Skin Dose Received by Patients in Cone Beam Computed Tomography, Spiral and Conventional Computed Tomography Scanninng

    Directory of Open Access Journals (Sweden)

    Rahimi A

    2011-12-01

    Full Text Available Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT, conventional and spiral computed tomography (CT.Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TLD chips were placed on facial, thyroid and end of sternum skin surface in patients referred for CT of the paranasal sinuses(3 TLD chips for each area to estimate the absorbed dose received by central part of radiation field, thyroid and out of field areas, respectively. The data were analyzed using one-way ANOVA and Tukey tests. Results: The dose delivered to the center of irradiated field was about 0.79±0.09 mGy in CBCT technique compared with 16.31±3.71 and 18.84±4.12 mGy for spiral and conventional CT, respectively. The received dose by the out of field areas was about 54 percent of central area dose. There was statistical significant relationship between the imaging modalities and absorbed dose received by patients (P=0.016. The least absorbed dose was for CBCT and the greatest dose was for conventional CT imaging technique.Conclusion: The dose delivered to central area of irradiated field in conventional and spiral CT imaging modalities was about 24 times greater than of that in CBCT. Also, the highest received dose was for central area of radiated field and the lowest dose was for the out of field areas.

  17. Dynamic 3D computed tomography scanner for vascular imaging

    Science.gov (United States)

    Lee, Mark K.; Holdsworth, David W.; Fenster, Aaron

    2000-04-01

    A 3D dynamic computed-tomography (CT) scanner was developed for imaging objects undergoing periodic motion. The scanner system has high spatial and sufficient temporal resolution to produce quantitative tomographic/volume images of objects such as excised arterial samples perfused under physiological pressure conditions and enables the measurements of the local dynamic elastic modulus (Edyn) of the arteries in the axial and longitudinal directions. The system was comprised of a high resolution modified x-ray image intensifier (XRII) based computed tomographic system and a computer-controlled cardiac flow simulator. A standard NTSC CCD camera with a macro lens was coupled to the electro-optically zoomed XRII to acquire dynamic volumetric images. Through prospective cardiac gating and computer synchronized control, a time-resolved sequence of 20 mm thick high resolution volume images of porcine aortic specimens during one simulated cardiac cycle were obtained. Performance evaluation of the scanners illustrated that tomographic images can be obtained with resolution as high as 3.2 mm-1 with only a 9% decrease in the resolution for objects moving at velocities of 1 cm/s in 2D mode and static spatial resolution of 3.55 mm-1 with only a 14% decrease in the resolution in 3D mode for objects moving at a velocity of 10 cm/s. Application of the system for imaging of intact excised arterial specimens under simulated physiological flow/pressure conditions enabled measurements of the Edyn of the arteries with a precision of +/- kPa for the 3D scanner. Evaluation of the Edyn in the axial and longitudinal direction produced values of 428 +/- 35 kPa and 728 +/- 71 kPa, demonstrating the isotropic and homogeneous viscoelastic nature of the vascular specimens. These values obtained from the Dynamic CT systems were not statistically different (p less than 0.05) from the values obtained by standard uniaxial tensile testing and volumetric measurements.

  18. O uso de tomografia computadorizada nas internações por Acidente Vascular Cerebral no Sistema Único de Saúde no Brasil Computerized tomography utilization for stroke inpatients in the Brazilian Health System

    Directory of Open Access Journals (Sweden)

    Cristina Lúcia Rocha Cubas Rolim

    2012-03-01

    Full Text Available O Acidente Vascular Cerebral é um dos principais motivos de internação no Sistema Único de Saúde. O exame de tomografia computadoriza tem sido indicado como o principal método diagnóstico de imagem para a definição do tratamento do Acidente Vascular Cerebral. O objetivo desse artigo é avaliar a utilização de exames de tomografia computadorizada em internações por Acidente Vascular Cerebral com base nas informações do Sistema de Informação Hospitalar do Sistema Único de Saúde. O universo de estudo incluiu as internações de pacientes adultos ocorridas no Brasil e financiadas pelo Sistema Único de Saúde entre abril de 2006 e dezembro de 2007. A análise dos dados foi descritiva para o conjunto de casos de Acidente Vascular Cerebral e para cada subgrupo separadamente. Das 328.087 internações por Acidente Vascular Cerebral, observou-se que em 73,5% o exame não foi realizado. Nas internações que realizaram tomografia computadorizada, 22,3% tiveram acesso a um exame e somente 4,2% a dois exames. Além de subutilizado, o exame de tomografia computadorizada, quando realizado, não trouxe melhora na codificação adequada do subgrupo da doença.Stroke is a leading reason for hospitalization in the Brazilian Health System. Computerized tomography has been indicated as the main diagnostic method to define stroke treatment. The aim of this paper was to evaluate the utilization of computerized tomography in hospitalizations due to stroke. The source of data was the Brazilian hospital information system. The study population comprised adult stroke inpatients in Brazil in the Brazilian Health System, between April 2006 and December 2007. Data analysis was descriptive for stroke and for each separate subgroup. Of the 328,087 stroke inpatients, 73.5% had not done a computerized tomography scan. Among hospitalizations that underwent a computed tomography scan, 22.3% had access to one test, and only 4.2% had two tests. Besides underuse

  19. Prognostic value of 18-fluorodeoxyglucose positron emission tomography-computed tomography in resectable colorectal cancer

    Institute of Scientific and Technical Information of China (English)

    Jang Eun Lee; Sang Woo Kim; Jin Su Kim; Kyu Yong Choi; Won Kyung Kang; Seong Taek Oh; Ie Ryung Yoo

    2012-01-01

    AIM:To assess the prognostic value of preoperative 18 fluorodeoxyglucose positron emission tomography (FDG-PET)/computed tomography (CT) in patients with resectable colorectal cancer.METHODS:One hundred sixty-three patients with resectable colorectal cancer who underwent FDG-PET/CT before surgery were included.Patient data including pathologic stage at presentation,histology,treatment,disease-free survival and the maximum standardized uptake value (SUVmax) of the primary tumor on FDGPET/CT were retrospectively analyzed.Median follow up duration was 756 (range,419-1355).The primary end point was disease-free survival.RESULTS:Twenty-five of 163 patients (15.3%) had recurrences.The median SUVmax values of the recurrence and no-recurrence groups were 8.9 (range,5-24) and 8.2 (range,0-23,P =0.998).Receiver operating characteristic (ROC) curve analysis showed no significant association between SUVmax and recurrence (area under the curve =0.5,P =0.998,95%CI:0.389-0.611).Because a statistically significant value was not found,SUVmax was dichotomized at its median of 8.6.The disease-free survival curve was analyzed using the median SUVmax (8.6) as the cut off.Univariate and multivariate analysis did not provide evidence that disease-free survival rates for the subgroups defined by the median SUVmax were significantly different (P =0.52,P =0.25).CONCLUSION:Our study suggests that the high FDG uptake of primary mass in resectable colorectal cancer doesn't have a significant relationship with tumor recurrence and disease-free survival.

  20. Diagnostic value for extrahepatic metastases of hepatocellular carcinoma in positron emission tomography/computed tomography scan

    Institute of Scientific and Technical Information of China (English)

    Ji Eun Lee; Jae Young Jang; Soung Won Jeong; Sae Hwan Lee; Sang Gyune Kim; Sang-Woo Cha; Young Seok Kim

    2012-01-01

    AIM:To evaluated the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) scan in diagnosis of hepatocellular carcinoma (HCC) and extrahepatic metastases.METHODS:A total of 138 patients with HCC who had both conventional imaging modalities and 18F-FDG PET/CT scan done between November 2006 and March 2011 were enrolled.Diagnostic value of each imaging modality for detection of extrahepatic metastases was evaluated.Clinical factors and tumor characteristics including PET imaging were analyzed as indicative factors for metastases by univariate and multivariate methods.RESULTS:The accuracy of chest CT was significantly superior compared with the accuracy of PET imaging for detecting lung metastases.The detection rate of metastatic pulmonary nodule ≥ 1 cm was 12/13(92.3%),when < 1 cm was 2/10 (20%) in PET imaging.The accuracy of PET imaging was significantly superior compared with the accuracy of bone scan for detecting bone metastases.In multivariate analysis,increased tumor size (≥ 5 cm) (P =0.042) and increased average standardized uptake value (SUV)uptake (P =0.028) were predictive factors for extrahepatic metastases.Isometabolic HCC in PET imaging was inversely correlated in multivariate analysis (P =0.035).According to the receiver operating characteristic curve,the optimal cutoff of average SUV to predict extrahepatic metastases was 3.4.CONCLUSION:18F-FDG PET/CT scan is invaluable for detection of lung metastases larger than 1 cm and bone metastases.Primary HCC having larger than 5 cm and increased average SUV uptake more than 3.4should be considered for extrahepatic metastases.

  1. Pitfalls in Positron Emission Tomography/Computed Tomography Imaging: Causes and Their Classifications

    Institute of Scientific and Technical Information of China (English)

    Tian-ran Li; Jia-he Tian; Hui Wang; Zi-qian Chen; Chun-lei Zhao

    2009-01-01

    Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the 18F-fluorodeoxyglucose (FDP) PET/CT imaging pitfalls through reviewing the PET/CT images of 872 patients. The pitfalls were divided into artifacts and infrequent physiological uptake, and the artifacts were further classified according to their causes. Meanwhile, we calculated the incidences of various pitfalls. Whether the PET/CT pitfalls influenced the diagnostic decision was analyzed. The appearances of pitfalls in PET were also described. Results Pitfalls could be found in PET/CT images of 684 (78.4%) patients. Artifacts were found in 664 (76.15%) patients, and could be classified into self-factor artifacts and equipment- or technology- related artifacts. Among self-factor artifacts, respiratory motion (57.5%), postprandial or hyperglycemia artifacts (2.41%), and metal or high density matter artifacts (1.38%) were frequent. As for equipment- or technology-related factors, injection point outleakage or radiotracer contamination (13.88%) and truncation artifacts (1.83%) were most common ones. Infrequent physiological FDG uptakes, including fatty uptake, endometrial uptake, and bilateral breast feeding period uptake, were found in 20 (2.29%) patients. Among all pitfalls, the artifacts in 92 (13.4%) patients and infrequent physiological uptakes in 6 (0.88%) patients affected the diagnostic results. Artifact images in PET could be described as hot or cold area and the images of infrequent physiological uptake were always shown as hot area. Conclusions The incidence of pitfall in PET/CT imaging was high and the causes of pitfalls are various. Among all causes that artifacts generated, respiratory motion is the most common. Some pitfalls may disturb clinical physicians' decision, so it is important to recognize artifacts and physiological uptake, and

  2. Single-photon emission computed tomography and positron-emission tomography assays for tissue oxygenation.

    Science.gov (United States)

    Chapman, J D; Schneider, R F; Urbain, J L; Hanks, G E

    2001-01-01

    Radiotherapy prescription can now be customized to target the major mechanism(s) of resistance of individual tumors. In that regard, functional imaging techniques should be exploited to identify the dominant mechanism(s). Tumor biology research has identified several mechanisms of tumor resistance that may be unique to radiation treatments. These fall into 3 broad areas associated with (1) tumor hypoxic fraction, (2) tumor growth rate, (3) and the intrinsic radiosensitivity of tumor clonogens. Imaging research has markers in various stages of development for quantifying relevant information about each of these mechanisms, and those that measure tumor oxygenation and predict for radioresistance are the most advanced. Positron-emission tomography (PET) measurement of oxygen 15 has yielded important information, particularly about brain tissue perfusion, metabolism, and function. Indirect markers of tumor hypoxia have exploited the covalent binding of bioreductive intermediates of azomycin-containing compounds whose uptakes are inversely proportional to intracellular oxygen concentrations. Pilot clinical studies with single-photon emission computed tomography (SPECT) and PET detection of radiolabeled markers to tumor hypoxia have been reported. Recently, other studies have attempted to exploit the reduction properties of both technetium and copper chelates for the selective deposition of radioactive metals in hypoxic tissues. A growing number of potentially useful isotopes are now available for labeling several novel chemicals that could have the appropriate specificity and sensitivity. Preclinical studies with "microSPECT" and "microPET" will be important to define the optimal radiodiagnostic(s) for measuring tissue oxygenation and for determining the time after their administration for optimal hypoxic signal acquisition. Radiolabeled markers of growth kinetics and intrinsic radiosensitivity of cells in solid tumors are also being developed. We conclude that

  3. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  4. Motion management in positron emission tomography/computed tomography for radiation treatment planning.

    Science.gov (United States)

    Bettinardi, Valentino; Picchio, Maria; Di Muzio, Nadia; Gilardi, Maria Carla

    2012-09-01

    Hybrid positron emission tomography (PET)/computed tomography (CT) scanners combine, in a unique gantry, 2 of the most important diagnostic imaging systems, a CT and a PET tomograph, enabling anatomical (CT) and functional (PET) studies to be performed in a single study session. Furthermore, as the 2 scanners use the same spatial coordinate system, the reconstructed CT and PET images are spatially co-registered, allowing an accurate localization of the functional signal over the corresponding anatomical structure. This peculiarity of the hybrid PET/CT system results in improved tumor characterization for oncological applications, and more recently, it was found to be also useful for target volume definition (TVD) and treatment planning in radiotherapy (RT) applications. In fact, the use of combined PET/CT information has been shown to improve the RT treatment plan when compared with that obtained by a CT alone. A limiting factor to the accuracy of TVD by PET/CT is organ and tumor motion, which is mainly due to patient respiration. In fact, respiratory motion has a degrading effect on PET/CT image quality, and this is also critical for TVD, as it can lead to possible tumor missing or undertreatment. Thus, the management of respiratory motion is becoming an increasingly essential component in RT treatment planning; indeed, it has been recognized that the use of personalized motion information can improve TVD and, consequently, permit increased tumor dosage while sparing surrounding healthy tissues and organs at risk. This review describes the methods used for motion management in PET/CT for radiation treatment planning. The article covers the following: (1) problems caused by organ and lesion motion owing to respiration, and the artifacts generated on CT, PET, and PET/CT images; (2) data acquisition and processing techniques used to manage respiratory motion in PET/CT studies; and (3) the use of personalized motion information for TVD and radiation treatment planning.

  5. 3D ultrasound computer tomography: update from a clinical study

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Kretzek, E.; Henrich, J.; Tukalo, A.; Gemmeke, H.; Kaiser, C.; Knaudt, J.; Ruiter, N. V.

    2016-04-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging method for breast cancer diagnosis. We developed a 3D USCT system and tested it in a pilot study with encouraging results: 3D USCT was able to depict two carcinomas, which were present in contrast enhanced MRI volumes serving as ground truth. To overcome severe differences in the breast shape, an image registration was applied. We analyzed the correlation between average sound speed in the breast and the breast density estimated from segmented MRIs and found a positive correlation with R=0.70. Based on the results of the pilot study we now carry out a successive clinical study with 200 patients. For this we integrated our reconstruction methods and image post-processing into a comprehensive workflow. It includes a dedicated DICOM viewer for interactive assessment of fused USCT images. A new preview mode now allows intuitive and faster patient positioning. We updated the USCT system to decrease the data acquisition time by approximately factor two and to increase the penetration depth of the breast into the USCT aperture by 1 cm. Furthermore the compute-intensive reflectivity reconstruction was considerably accelerated, now allowing a sub-millimeter volume reconstruction in approximately 16 minutes. The updates made it possible to successfully image first patients in our ongoing clinical study.

  6. Compensation for air voids in photoacoustic computed tomography image reconstruction

    Science.gov (United States)

    Matthews, Thomas P.; Li, Lei; Wang, Lihong V.; Anastasio, Mark A.

    2016-03-01

    Most image reconstruction methods in photoacoustic computed tomography (PACT) assume that the acoustic properties of the object and the surrounding medium are homogeneous. This can lead to strong artifacts in the reconstructed images when there are significant variations in sound speed or density. Air voids represent a particular challenge due to the severity of the differences between the acoustic properties of air and water. In whole-body small animal imaging, the presence of air voids in the lungs, stomach, and gastrointestinal system can limit image quality over large regions of the object. Iterative reconstruction methods based on the photoacoustic wave equation can account for these acoustic variations, leading to improved resolution, improved contrast, and a reduction in the number of imaging artifacts. However, the strong acoustic heterogeneities can lead to instability or errors in the numerical wave solver. Here, the impact of air voids on PACT image reconstruction is investigated, and procedures for their compensation are proposed. The contributions of sound speed and density variations to the numerical stability of the wave solver are considered, and a novel approach for mitigating the impact of air voids while reducing the computational burden of image reconstruction is identified. These results are verified by application to an experimental phantom.

  7. Iterative image reconstruction and its role in cardiothoracic computed tomography.

    Science.gov (United States)

    Singh, Sarabjeet; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Padole, Atul; Lira, Diego; Kalra, Mannudeep K

    2013-11-01

    Revolutionary developments in multidetector-row computed tomography (CT) scanner technology offer several advantages for imaging of cardiothoracic disorders. As a result, expanding applications of CT now account for >85 million CT examinations annually in the United States alone. Given the large number of CT examinations performed, concerns over increase in population-based risk for radiation-induced carcinogenesis have made CT radiation dose a top safety concern in health care. In response to this concern, several technologies have been developed to reduce the dose with more efficient use of scan parameters and the use of "newer" image reconstruction techniques. Although iterative image reconstruction algorithms were first introduced in the 1970s, filtered back projection was chosen as the conventional image reconstruction technique because of its simplicity and faster reconstruction times. With subsequent advances in computational speed and power, iterative reconstruction techniques have reemerged and have shown the potential of radiation dose optimization without adversely influencing diagnostic image quality. In this article, we review the basic principles of different iterative reconstruction algorithms and their implementation for various clinical applications in cardiothoracic CT examinations for reducing radiation dose.

  8. 23.4% saline decreases brain tissue volume in severe hepatic encephalopathy as assessed by a quantitative computed tomography marker

    Science.gov (United States)

    Liotta, Eric M; Lizza, Bryan D; Romanova, Anna L; Guth, James C; Berman, Michael D; Carroll, Timothy J; Francis, Brandon; Ganger, Daniel; Ladner, Daniela P; Maas, Matthew B; Naidech, Andrew M

    2016-01-01

    Objective Cerebral edema is common in severe hepatic encephalopathy and may be life-threatening. Bolus 23.4% hypertonic saline (HTS) improves surveillance neuromonitoring scores, although its mechanism of action is not clearly established. We investigated the hypothesis that bolus HTS decreases cerebral edema in severe hepatic encephalopathy utilizing a quantitative technique to measure brain and CSF volume changes. Design Retrospective analysis of serial computed tomography (CT) scans and clinical data for a case-control series was performed. Setting Intensive care units of a tertiary care hospital. Patients Patients with severe hepatic encephalopathy treated with 23.4% HTS and control patients who did not receive 23.4% HTS. Methods We used clinically obtained CT scans to measure volumes of the ventricles, intracranial CSF, and brain using a previously validated semi-automated technique (Analyze Direct; Overland Park, KS). Volumes before and after 23.4% HTS were compared with Wilcoxon signed-rank test. Associations between total CSF volume, ventricular volume, serum sodium, and Glasgow Coma Scale Scores were assessed using Spearman correlation. Results Eleven patients with 18 administrations of 23.4% HTS met inclusion criteria. Total CSF (median 47.6 [35.1–69.4] to 61.9 [47.7–87.0] mL, pbrain tissue volume. Total CSF and ventricular volume change may be useful quantitative measures to assess cerebral edema in severe hepatic encephalopathy. PMID:26308431

  9. Computed tomographic (CT) scans in cerebral palsy (CP)

    Energy Technology Data Exchange (ETDEWEB)

    Kolawole, T.M.; Patel, P.J. (King Saud Univ., Riyadh (Saudi Arabia). Dept. of Radiology); Mahdi, A.H. (King Saud Univ., Riyadh (Saudi Arabia). Dept. of Paediatrics)

    1989-11-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.).

  10. Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

    Science.gov (United States)

    Fan, Audrey P; Jahanian, Hesamoddin; Holdsworth, Samantha J; Zaharchuk, Greg

    2016-05-01

    Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [(15)O]-water radiotracer. Although [(15)O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [(15)O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.

  11. Diagnostic value of high resolutional computed tomography of spine

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S. M.; Im, S. K.; Sohn, M. H.; Lim, K. Y.; Kim, J. K.; Choi, K. C. [Jeonbug National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Non-enhanced high resolution computed tomography provide clear visualization of soft tissue in the canal and bony details of spine, particularly of the lumbar spine. We observed 70 cases of spine CT using GE CT/T 8800 scanner during the period from Dec. 1982 to Sep. 1983 at Jeonbug National University Hospital. The results were as follows: 1. The sex distribution of cases were 55 males and 15 females : age was from 17 years to 67 years; sites were 11 cervical spine, 5 thoracic spine and 54 lumbosacral spine. 2. CT diagnosis showed 44 cases of lumbar disc herniation, 7 cases of degenerative disease, 3 cases of spine fracture and each 1 cases of cord tumor, metastatic tumor, spontaneous epidural hemorrhage, epidural abscess, spine tbc., meningocele with diastematomyelia. 3. Sites of herniated nucleus pulposus were 34 cases (59.6%) between L4-5 interspace and 20 cases (35.1%) between L5-S1 interspace. 13 cases (29.5%) of lumbar disc herniation disclosed multiple lesions. Location of herniation were central type in 28 cases(49.1%), right-central type in 12 cases(21.2%), left-central type in 11 cases (19.2%) and far lateral type in 6 cases(10.5%). 4. CT findings of herniated nucleus pulposus were as follows : focal protrusion of posterior disc margin and obliteration of anterior epidural fat in all cases, dural sac indentation in 26 cases(45.6%), soft tissue mass in epidural fat in 21 cases(36.8%), displacement or compression of nerve root sheath in 12 cases(21%). 5. Multiplanar reformatted images and Blink mode provide more effective evaluation about definite level and longitudinal dimension of lesion, such as obscure disc herniation, spine fracture, cord tumor and epidural abscess. 6. Non-enhanced and enhanced high resolutional computed tomography were effectively useful in demonstrating compression or displacement of spinal cord and nerve root, examing congenital anomaly such as meningocele and primary or metastatic spinal lesions.

  12. Regional cerebral blood flow measured with N-isopropyl-p-[[sup 123]I]iodoamphetamine single-photon emission tomography in patients with Joseph disease

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Naoya (Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan)); Odano, Ikuo (Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan)); Nishihara, Mamiko (Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan)); Yuasa, Tatsuhiko (Dept. of Neurology, Tokyo Medical and Dental Univ. School of Medicine, Tokyo (Japan)); Sakai, Kunio (Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan))

    1994-07-01

    Regional cerebral blood flow (rCBF) was measured in five Japanese patients who were clinically diagnosed as having Joseph disease, also called Machado-Joseph disease or Azorean disease, using N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and single-photon emission tomography (SPET). Cerebellar atrophy was evaluated by a five-step rating scale as defined on X-ray computed tomography (X-CT). Compared with ten age-matched normal controls (mean cerebellar CBF [+-] SD: 66.9 [+-] 6.6 ml/100 g/min), rCBF in patients with Joseph disease was significantly decreased in the cerebellum (mean [+-] SD: 50.2 [+-] 7.3 ml/100 g/min). No significant relationship, however, was found between the decrease in rCBF in the cerebellum and the degree of cerebellar atrophy on X-CT. rCBF in the cerebellum was minimally decreased in one patient who had severe cerebellar atrophy and in two patients with moderate atrophy. These data may support the findings that Purkinje cells in the cerebellum are almost normal in Joseph disease, and that the granular and molecular layers remain intact in spite of cortical atrophy of the cerebellum. It is concluded that [[sup 123]I]-IMP SPET is able to identify pathological and metabolic changes in the cerebellum that do not appear on X-CT or magnetic resonance imaging, and thus is useful for the diagnosis of Joseph disease. (orig.)

  13. Hydrocephalus associated with subarachnoid hemorrhage. Clinical study by computed tomography, radioisotope cisternography and constant infusion test

    Energy Technology Data Exchange (ETDEWEB)

    Nosaka, Y. (Okayama Univ. (Japan). School of Medicine)

    1981-02-01

    Thirteen patients exhibited a communicating hydrocephalus following subarachnoid hemorrhage secondary to ruptured intracranial aneurysms and were treated with shunt procedures. The interval between subarachnoid hemorrhage and surgery averaged 9 weeks. Seven of the patients showed improvement. The prognostic value for surgical management was evaluated on the basis of three different diagnostic examinations (computed tomography (CT), cisternography and constant infusion test). A correct diagnosis was obtained in 78 per cent in cisternography, and 63 per cent in infusion test and CT. All patients responding to surgery showed a typical pattern in cisternography, consisting of ventricular retention of radiopharmaceutical tracer for 48 h or longer in association with no radioactivity over the cerebral hemispheres. The constant infusion test correlated well with typical cisternographic patterns. CT is useful in demonstrating pathophysiological changes in hydrocephalus. Periventricular hypodensity was visible in patients with normal or slightly elevated intracranial pressure, accompanied by fairly rapid deterioration. All of them responded well to shunting. In most cases which benefited from the shunt, the postoperative CT showed not only normal-sized ventricles but also marked regression of the hypodensity over a short period.

  14. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Science.gov (United States)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  15. Contrast-enhanced three-dimensional computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kuroiwa, Toshihiko; Deguchi, Jun; Arai, Motohiro; Tanaka, Hideo; Ohta, Tomio; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1997-12-01

    To evaluate the usefulness of contrast-enhanced spiral (helical) scanning computed tomography (CT) in patients with various brain tumors, a non ionic contrast medium was injected intravenously in ten patients with meningioma, five with vestibular schwannoma, and five with pituitary adenoma. Images were taken by spiral scan at an X-ray beam width of 1 or 2 mm. The volume data obtained were combined at 0.5-1 mm intervals for the three-dimensional (3-D) image reconstruction, by the volume rendering method. Each image was separated by CT number into bone, blood vessel, contrast-enhanced tumor, and cerebral parenchyma. In some subjects, a pair of images was reconstructed to allow stereoscopic viewing at a parallax angle of 6 degrees. Three-dimensional relationship between tumors and other structures was easily understood, permitting pre-operative prediction of the operative field and also a view of the area after tumor excision. The present method surpassed conventional CT techniques in terms of clarity of the 3-D relationship, and surpassed MRI and MRA in terms of clarity of relationship between the tumor and skull. These results confirm that this method appears to be applicable in routine clinical situations with minimal invasiveness, high degree of safety, and short examination time. (author)

  16. Rotational flat-panel computed tomography in diagnostic and interventional neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Doerfler, A.; Struffert, T.; Engelhorn, T.; Richter, C. [Abt. fuer Neuroradiologie, Universitaetsklinikum Erlangen, Friedrich-Alexander-Univ. Erlangen-Nuernberg (Germany)

    2008-10-15

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with X-ray film or film-screen combinations, flat-panel detector technology has become widely accepted for neuroangiographic imaging. In particular flat-panel detector computed tomography (FD-CT) which uses rotational C-arm-mounted flat-panel detector technology is capable of volumetric imaging with high spatial resolution. As ''Angiographic CT'' FD-CT may be helpful during many diagnostic and neurointerventional procedures, i.e. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolizations of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize periprocedural hemorrhage and may thus improve rapid complication management without the need for patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single machine. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. This paper briefly reviews the technical principles of FD technology and then focuses on possible applications in diagnostic and interventional neuroradiology. (orig.)

  17. The Role of Pulmonary Veins in Cancer Progression from a Computed Tomography Viewpoint

    Science.gov (United States)

    Chang, Hung; Liao, Tzu-Yao; Wen, Ming-Sheng; Yu, Chih-Teng

    2016-01-01

    Background. We studied the role of pulmonary veins in cancer progression using computed tomography (CT) scans. Methods. We obtained data from 260 patients with pulmonary vein obstruction syndrome (PVOS). We used CT scans to investigate pulmonary lesions in relation to pulmonary veins. We divided the lesions into central and peripheral lesions by their anatomical location: in the lung parenchymal tissue or pulmonary vein; in the superior or inferior pulmonary vein; and by unilateral or bilateral presence in the lungs. Results. Of the 260 PVOS patients, 226 (87%) had central lesions, 231 (89%) had peripheral lesions, and 190 (75%) had mixed central and peripheral lesions. Among the 226 central lesions, 93% had lesions within the superior pulmonary vein, either bilaterally or unilaterally. Among the 231 peripheral lesions, 65% involved bilateral lungs, 70% involved lesions within the inferior pulmonary veins, and 23% had obvious metastatic extensions into the left atrium. All patients exhibited nodules within their pulmonary veins. The predeath status included respiratory failure (40%) and loss of consciousness (60%). Conclusion. CT scans play an important role in following tumor progression within pulmonary veins. Besides respiratory distress, PVOS cancer cells entering centrally can result in cardiac and cerebral events and loss of consciousness or can metastasize peripherally from the pulmonary veins to the lungs.

  18. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  19. Hydrocephalus associated with subarachnoid hemorrhage: clinical study by computed tomography, radioisotope cisternography and constant infusion test.

    Directory of Open Access Journals (Sweden)

    Nosaka,Yoshiki

    1981-02-01

    Full Text Available Thirteen patients exhibited a communicating hydrocephalus following subarachnoid hemorrhage secondary to ruptured intracranial aneurysms and were treated with shunt procedures. The interval between subarachnoid hemorrhage and surgery averaged 9 weeks. Seven of the patients showed improvement. The prognostic value for surgical management was evaluated on the basis of three different diagnostic examinations (computed tomography(CT, cisternography and constant infusion test. A correct diagnosis was obtained in 78 per cent in cisternography, and 63 per cent in infusion test and CT. All patients responding to surgery showed a typical pattern in cisternography, consisting of ventricular retention of radiopharmaceutical tracer for 48 h or longer in association with no radioactivity over the cerebral hemispheres. The constant infusion test correlated well with typical cisternographic patterns. CT is useful in demonstrating pathophysiological changes in hydrocephalus. Periventricular hypodensity was visible in patients with normal or slightly elevated intracranial pressure, accompanied by fairly rapid deterioration. All of them responded well to shunting. In most cases which benefited from the shunt, the postoperative CT showed not only normal-sized ventricles but also marked regression of the hypodensity over a short period.

  20. The hemodynamics in intracranial aneurysm ruptured region with active contrast leakage during computed tomography angiography

    Science.gov (United States)

    Li, Ming-Lung; Wang, Yi-Chou; Liou, Tong-Miin; Lin, Chao-An

    2014-10-01

    Precise locations of rupture region under contrast agent leakage of five ruptured cerebral artery aneurysms during computed tomography angiography, which is to our knowledge for the first time, were successfully identified among 101 patients. These, together with numerical simulations based on the reconstructed aneurysmal models, were used to analyze hemodynamic parameters of aneurysms under different cardiac cyclic flow rates. For side wall type aneurysms, different inlet flow rates have mild influences on the shear stresses distributions. On the other hand, for branch type aneurysms, the predicted wall shear stress (WSS) correlates strongly with the increase of inlet vessel velocity. The mean and time averaged WSSes at rupture regions are found to be lower than those over the surface of the aneurysms. Also, the levels of the oscillatory shear index (OSI) are higher than the reported threshold value, supporting the assertion that high OSI correlates with rupture of the aneurysm. However, the present results also indicate that OSI level at the rupture region is relatively lower.

  1. Nano-computed tomography. Technique and applications; Nanocomputertomografie. Technik und Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Kampschulte, M.; Sender, J.; Litzlbauer, H.D.; Althoehn, U.; Schwab, J.D.; Alejandre-Lafont, E.; Martels, G.; Krombach, G.A. [University Hospital Giessen (Germany). Dept. of Diagnostic and Interventional Radiology; Langheinirch, A.C. [BG Trauma Hospital Frankfurt/Main (Germany). Dept. of Diagnostic and Interventional Radiology

    2016-02-15

    Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols, a superior spatial resolution up to 400 nm (10 % MTF) can be achieved, thereby exceeding the resolution capacity of typical micro-CT systems. The technical concept of nano-CT imaging as well as the basics of specimen preparation are demonstrated exemplarily. Characteristics of atherosclerotic plaques (intraplaque hemorrhage and calcifications) in a murine model of atherosclerosis (ApoE{sub (-/-)}/LDLR{sub (-/-)} double knockout mouse) are demonstrated in the context of superior spatial resolution in comparison to micro-CT. Furthermore, this article presents the application of nano-CT for imaging cerebral microcirculation (murine), lung structures (porcine), and trabecular microstructure (ovine) in contrast to micro-CT imaging. This review shows the potential of nano-CT as a radiological method in biomedical basic research and discusses the application of experimental, high resolution CT techniques in consideration of other high resolution cross-sectional imaging techniques.

  2. Computer-aided classification of lung nodules on computed tomography images via deep learning technique.

    Science.gov (United States)

    Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen

    2015-01-01

    Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain.

  3. Hepatic angiomyolipoma: Dynamic computed tomography features and clinical correlation

    Institute of Scientific and Technical Information of China (English)

    Bin Yang; Wen-Hui Chen; Qiao-Yun Li; Jing-Jing Xiang; Ru-Jun Xu

    2009-01-01

    AIM: To study the dynamic computed tomography (CT) features of hepatic angiomyolipoma (AML) in patients with or without tuberous sclerosis complex (TSC). METHODS: The clinical information, CT findings and histopathological results of hepatic AML were analyzed retrospectively in 10 patients. RESULTS: Hepatic AML was prone to occur in female patients (7/10), and most of the patients (8/10) had no specific symptoms. All tumors presented as welldefined, unenveloped nodules in the liver. Six patients with sporadic hepatic AML had a solitary hepatic nodule with a definite fat component. Non-fat components of the hepatic lesions were enhanced earlier and persistently. Prominent central vessels were noted in the portal venous phase in three patients. In four patients with hepatic AML and TSC, most of the nodules were within the peripheral liver. Seven fatdeficient nodules were found with earlier contrast enhancement and rapid contrast material washout in two patients. Lymphangioleiomyomatosis was found in one patient.CONCLUSION: Imaging features of hepatic AML are characteristic. Correct diagnosis preoperatively can be made in combination with clinical features.

  4. X-ray computed tomography for additive manufacturing: a review

    Science.gov (United States)

    Thompson, A.; Maskery, I.; Leach, R. K.

    2016-07-01

    In this review, the use of x-ray computed tomography (XCT) is examined, identifying the requirement for volumetric dimensional measurements in industrial verification of additively manufactured (AM) parts. The XCT technology and AM processes are summarised, and their historical use is documented. The use of XCT and AM as tools for medical reverse engineering is discussed, and the transition of XCT from a tool used solely for imaging to a vital metrological instrument is documented. The current states of the combined technologies are then examined in detail, separated into porosity measurements and general dimensional measurements. In the conclusions of this review, the limitation of resolution on improvement of porosity measurements and the lack of research regarding the measurement of surface texture are identified as the primary barriers to ongoing adoption of XCT in AM. The limitations of both AM and XCT regarding slow speeds and high costs, when compared to other manufacturing and measurement techniques, are also noted as general barriers to continued adoption of XCT and AM.

  5. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  6. Evaluation of myocardial bridging by coronary computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Marcio Vinicius Lins; Rabelo, Daniel Rocha; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil); Garretto, Luiza Samarane; Paula, Marcela Mascarenhas De; Carvalho, Marina Oliveira; Alves, Marina Rangel Moreira Barros [Faculdade de Saude e Ecologia Humana (FASEH), Vespasiano, MG (Brazil)

    2013-01-15

    The myocardial bridge (MB) is defined as a segment of an epicardial coronary artery that has an intramural course in the myocardium. Although MB is clinically silent in most cases, has been associated with myocardial ischemia, arrhythmias and sudden death. Coronary conventional angiography is the gold standard for detection of MB, but is invasive and cannot be sufficiently sensitive compared to autopsy studies. Recently, multislice computed tomography of coronary arteries (MCTCA) has allowed the detection of coronary artery course, including PM. Objectives: to evaluate MB prevalence in patients with suspected coronary artery disease undergoing MCTCA and to evaluate the predictive value of this method at medium term. Methods: during the period 2008 to 2011, 498 consecutive patients were examined by TMC for the diagnosis of coronary artery disease, being conducted to evaluate the presence of BM and followed for a mean follow-up of 23 months for the occurrence of cardiovascular hard events (death, hospitalization or revascularization). Results: patients mean age was 55.3 ± 14.2, being male 71.1%. Among the patients, 7.6% (38 patients) showed MB. Main findings included angina pectoris in 40% and a positive stress test in 34%. 34.2% had atherosclerotic disease, and one patient had significant coronary stenosis. During follow-up, no patients showed adverse events. Conclusion: MCTCA is a noninvasive technique with high accuracy in anatomical evaluation of the coronary arteries and may be particularly useful to assess the incidence, location and morphology of myocardial bridging in vivo. (author)

  7. Reproducibility of aortic annulus measurements by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schuhbaeck, Annika; Achenbach, Stephan [University of Erlangen, Department of Cardiology, Erlangen (Germany); University of Giessen, Department of Cardiology, Giessen (Germany); Pflederer, Tobias; Marwan, Mohamed; Schmid, Jasmin; Arnold, Martin [University of Erlangen, Department of Cardiology, Erlangen (Germany); Nef, Holger; Rixe, Johannes; Hecker, Franziska [University of Giessen, Department of Cardiology, Giessen (Germany); Schneider, Christian [University of Giessen, Department of Radiology, Giessen (Germany); Lell, Michael; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany)

    2014-08-15

    To evaluate a systematic approach for measurement of aortic annulus dimensions by cardiac computed tomography. CT data sets of 64 patients were evaluated. An oblique cross-section aligned with the aortic root was created by systematically identifying the caudal insertion points of the three aortic cusps and sequentially aligning them in a double oblique plane. Aortic annulus dimensions, distances of coronary ostia and a suitable fluoroscopic projection angle were independently determined by two observers. Interobserver intraclass correlation coefficients (ICC) for aortic annulus diameters were excellent (ICC 0.89-0.93). Agreement for prosthesis size selection was excellent (k = 0.86 for mean, k = 0.84 for area-derived and k = 0.91 for circumference-derived diameter). Mean distances of the left/right coronary ostium were 13.4 ± 2.4/14.4 ± 2.8 mm for observer 1 and 13.2 ± 2.7/13.5 ± 3.2 mm for observer 2 (p = 0.30 and p = 0.0001, respectively; ICC 0.76/0.77 for left/right coronary artery). A difference of less than 10 for fluoroscopic projection angle was achieved in 84.3 % of patients. A systematic approach to generate a double oblique imaging plane exactly aligned with the aortic annulus demonstrates high interobserver and intraobserver agreements for derived measurements which are not influenced by aortic root calcification. (orig.)

  8. Compressing industrial computed tomography images by means of contour coding

    Science.gov (United States)

    Jiang, Haina; Zeng, Li

    2013-10-01

    An improved method for compressing industrial computed tomography (CT) images is presented. To have higher resolution and precision, the amount of industrial CT data has become larger and larger. Considering that industrial CT images are approximately piece-wise constant, we develop a compression method based on contour coding. The traditional contour-based method for compressing gray images usually needs two steps. The first is contour extraction and then compression, which is negative for compression efficiency. So we merge the Freeman encoding idea into an improved method for two-dimensional contours extraction (2-D-IMCE) to improve the compression efficiency. By exploiting the continuity and logical linking, preliminary contour codes are directly obtained simultaneously with the contour extraction. By that, the two steps of the traditional contour-based compression method are simplified into only one. Finally, Huffman coding is employed to further losslessly compress preliminary contour codes. Experimental results show that this method can obtain a good compression ratio as well as keeping satisfactory quality of compressed images.

  9. Dual-energy computed tomography for gout diagnosis and management.

    Science.gov (United States)

    Dalbeth, Nicola; Choi, Hyon K

    2013-01-01

    The central feature of gout is deposition of monosodium urate crystals. Dual-energy computed tomography (DECT) is a recently developed advanced imaging method that enables visualisation of urate deposits by analysis of the chemical composition of the scanned materials. This review summarises recent research describing the use of DECT in gout management. This technology may assist in both diagnosis and monitoring of the disease. Studies of patients with established disease indicate diagnostic accuracy for gout is high. Excellent inter-reader agreement has been reported for detection of urate deposits by use of DECT. Automated volume assessment software also enables rapid and reproducible measurement of urate deposits within tophi, suggesting that this modality may be useful for monitoring the disease. Although several case reports indicate DECT can be used to reveal reduction in the size of urate deposits, the sensitivity to change in response to urate-lowering therapy has not yet been systematically reported. DECT images reveal variable urate deposition within tophi of the same physical size. The ability to visualise urate deposits in tissue may provide new insights into the pathology and mechanisms of gout.

  10. Computed tomography perfusion imaging denoising using Gaussian process regression

    Science.gov (United States)

    Zhu, Fan; Carpenter, Trevor; Rodriguez Gonzalez, David; Atkinson, Malcolm; Wardlaw, Joanna

    2012-06-01

    Brain perfusion weighted images acquired using dynamic contrast studies have an important clinical role in acute stroke diagnosis and treatment decisions. However, computed tomography (CT) images suffer from low contrast-to-noise ratios (CNR) as a consequence of the limitation of the exposure to radiation of the patient. As a consequence, the developments of methods for improving the CNR are valuable. The majority of existing approaches for denoising CT images are optimized for 3D (spatial) information, including spatial decimation (spatially weighted mean filters) and techniques based on wavelet and curvelet transforms. However, perfusion imaging data is 4D as it also contains temporal information. Our approach using Gaussian process regression (GPR), which takes advantage of the temporal information, to reduce the noise level. Over the entire image, GPR gains a 99% CNR improvement over the raw images and also improves the quality of haemodynamic maps allowing a better identification of edges and detailed information. At the level of individual voxel, GPR provides a stable baseline, helps us to identify key parameters from tissue time-concentration curves and reduces the oscillations in the curve. GPR is superior to the comparable techniques used in this study.

  11. Quantitative Computed Tomography and image analysis for advanced muscle assessment

    Directory of Open Access Journals (Sweden)

    Kyle Joseph Edmunds

    2016-06-01

    Full Text Available Medical imaging is of particular interest in the field of translational myology, as extant literature describes the utilization of a wide variety of techniques to non-invasively recapitulate and quantity various internal and external tissue morphologies. In the clinical context, medical imaging remains a vital tool for diagnostics and investigative assessment. This review outlines the results from several investigations on the use of computed tomography (CT and image analysis techniques to assess muscle conditions and degenerative process due to aging or pathological conditions. Herein, we detail the acquisition of spiral CT images and the use of advanced image analysis tools to characterize muscles in 2D and 3D. Results from these studies recapitulate changes in tissue composition within muscles, as visualized by the association of tissue types to specified Hounsfield Unit (HU values for fat, loose connective tissue or atrophic muscle, and normal muscle, including fascia and tendon. We show how results from these analyses can be presented as both average HU values and compositions with respect to total muscle volumes, demonstrating the reliability of these tools to monitor, assess and characterize muscle degeneration.

  12. A framework of modeling detector systems for computed tomography simulations

    Science.gov (United States)

    Youn, H.; Kim, D.; Kim, S. H.; Kam, S.; Jeon, H.; Nam, J.; Kim, H. K.

    2016-01-01

    Ultimate development in computed tomography (CT) technology may be a system that can provide images with excellent lesion conspicuity with the patient dose as low as possible. Imaging simulation tools have been cost-effectively used for these developments and will continue. For a more accurate and realistic imaging simulation, the signal and noise propagation through a CT detector system has been modeled in this study using the cascaded linear-systems theory. The simulation results are validated in comparisons with the measured results using a laboratory flat-panel micro-CT system. Although the image noise obtained from the simulations at higher exposures is slightly smaller than that obtained from the measurements, the difference between them is reasonably acceptable. According to the simulation results for various exposure levels and additive electronic noise levels, x-ray quantum noise is more dominant than the additive electronic noise. The framework of modeling a CT detector system suggested in this study will be helpful for the development of an accurate and realistic projection simulation model.

  13. Necrotic stercoral colitis: Importance of computed tomography findings

    Institute of Scientific and Technical Information of China (English)

    Cheng-Hsien Wu; Li-Jen Wang; Yon-Cheong Wong; Chen-Chih Huang; Chien-Cheng Chen; Chao-Jan Wang; Jen-Feng Fang; Chuen Hsueh

    2011-01-01

    AIM: To study the computed tomography (CT) signs in facilitating early diagnosis of necrotic stercoral colitis(NSC).METHODS: Ten patients with surgically and pathologically confirmed NSC were recruited from the Clinico-Pathologic-Radiologic conference at Chang Gung MemorialHospital, Taoyuan, Taiwan. Their CT images and medical records were reviewed retrospectively to correlate CT findings with clinical presentation.RESULTS: All these ten elderly patients with a mean age of 77.1 years presented with acute abdomen at our Emergency Room. Nine of them were with systemic medmedical disease and 8 with chronic constipation. Seven were with leukocytosis, two with low-grade fever, two with peritoneal sign, and three with hypotensive shock. Only one patient was with radiographic detected abnormal gas. Except the crux of fecal impaction, the frequency of the CT signs of NSC were, proximal colon dilatation (20%),colon wall thickening (60%), dense mucosa (62.5%),mucosal sloughing (10%), perfusion defect (70%),pericolonic stranding (80%), abnormal gas (50%) with pneumo-mesocolon (40%) in them, pericolonic abscess(20%). The most sensitive signs in decreasing order were pericolonic stranding, perfusion defect, dense mucosal,detecting about 80%, 70%, and 62.5% of the cases, respectively.CONCLUSION: Awareness of NSC and familiarity with the CT diagnostic signs enable the differential diagnosis between NSC and benign stool impaction.

  14. Coronary revascularization treatment based on dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dikkers, R.; Willems, T.P.; Jonge, G.J. de; Zaag-Loonen, H.J. van der; Ooijen, P.M.A. van; Oudkerk, M. [University of Groningen, Department of Radiology, Groningen (Netherlands); University Medical Center, Groningen (Netherlands); Piers, L.H.; Tio, R.A.; Zijlstra, F. [University of Groningen, Department of Cardiology, Groningen (Netherlands); University Medical Center, Groningen (Netherlands)

    2008-09-15

    Therapy advice based on dual-source computed tomography (DSCT) in comparison with coronary angiography (CAG) was investigated and the results evaluated after 1-year follow-up. Thirty-three consecutive patients (mean age 61.9 years) underwent DSCT and CAG and were evaluated independently. In an expert reading (the ''gold standard''), CAG and DSCT examinations were evaluated simultaneously by an experienced radiologist and cardiologist. Based on the presence of significant stenosis and current guidelines, therapy advice was given by all readers blinded from the results of other readings and clinical information. Patients were treated based on a multidisciplinary team evaluation including all clinical information. In comparison with the gold standard, CAG had a higher specificity (91%) and positive predictive value (PPV) (95%) compared with DSCT (82% and 91%, respectively). DSCT had a higher sensitivity (96%) and negative predictive value (NPV) (89%) compared with CAG (91% and 83%, respectively). The DSCT-based therapy advice did not lead to any patient being denied the revascularization they needed according to the multidisciplinary team evaluation. During follow-up, two patients needed additional revascularization. The high NPV for DSCT for revascularization assessment indicates that DSCT could be safely used to select patients benefiting from medical therapy only. (orig.)

  15. Computed tomography of the pancreas in diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Katsumata, Kazuo (Katsumata Hospital, Nagoya (Japan)); Katsumata, Yoshinao; Nakagawa, Takeo; Sakuma, Sadayuki

    1984-08-01

    Computed tomography (CT) of the pancreas usually shows either a smooth or granular image in the margin and contents. We have divided these images into three types in both the margin and contents (smooth type, fine-granule type and rough-granule type). These types were analyzed in relation to the clinical features of diabetes mellitus. Four hundred and six controls without diabete, mellitus, gallstones, pancreatitis, liver cirrhosis or malignant tumors were analyzed as a control group, and 121 diabetic patients without these four complications were analyzed as a diabetic group. The following results were obtained. 1. In the control group, the younger obese persons showed high incidence of the rough-granule type of the pancreatic margin and contents. This decreased with an increase in age. 2. In the diabetic group, the incidence of the rough-granule type of both the pancreatic margin and contents was high among the elderly and older patients. Lean patients did not show the rough-granule type of pancreatic contents. The incidence of the rough-granule type tended to decrease as the clinical features became worse. 3. Pancreata having the rough-granule type of pancreatic contents were considered to be rich in fat tissue.

  16. Clinical significance of computed tomography assessment for third molar surgery

    Institute of Scientific and Technical Information of China (English)

    Kenji; Nakamori; Kei; Tomihara; Makoto; Noguchi

    2014-01-01

    Surgical extraction of the third molar is the most commonly performed surgical procedure in the clinical practice of oral surgery.Third molar surgery is warranted when there is inadequate space for eruption,malpositioning,or risk for cyst or odontogenic tumor formation.Preoperative assessment should include a detailed morphologic analysis of the third molar and its relationship to adjacent structures and surrounding tissues.Due to developments in medical engineering technology,computed tomography(CT)now plays a critical role in providing the clear images required for adequate assessment prior to third molar surgery.Removal of the maxillary third molar is associated with a risk for maxillary sinus perforation,whereas removal of the mandibular third molar can put patients at risk for a neurosensory deficit from damage to the lingual nerve or inferior alveolar nerve.Multiple factors,including demographic,anatomic,and treatment-related factors,influence the incidence of nerve injury during or following removal of the third molar.CT assessment of the third molar prior to surgery can identify some of these risk factors,such as the absence of cortication between themandibular third molar and the inferior alveolar canal,prior to surgery to reduce the risk for nerve damage.This topic highlight presents an overview of the clinical significance of CT assessment in third molar surgery.

  17. Clinical significance of computed tomography assessment for third molar surgery.

    Science.gov (United States)

    Nakamori, Kenji; Tomihara, Kei; Noguchi, Makoto

    2014-07-28

    Surgical extraction of the third molar is the most commonly performed surgical procedure in the clinical practice of oral surgery. Third molar surgery is warranted when there is inadequate space for eruption, malpositioning, or risk for cyst or odontogenic tumor formation. Preoperative assessment should include a detailed morphologic analysis of the third molar and its relationship to adjacent structures and surrounding tissues. Due to developments in medical engineering technology, computed tomography (CT) now plays a critical role in providing the clear images required for adequate assessment prior to third molar surgery. Removal of the maxillary third molar is associated with a risk for maxillary sinus perforation, whereas removal of the mandibular third molar can put patients at risk for a neurosensory deficit from damage to the lingual nerve or inferior alveolar nerve. Multiple factors, including demographic, anatomic, and treatment-related factors, influence the incidence of nerve injury during or following removal of the third molar. CT assessment of the third molar prior to surgery can identify some of these risk factors, such as the absence of cortication between the mandibular third molar and the inferior alveolar canal, prior to surgery to reduce the risk for nerve damage. This topic highlight presents an overview of the clinical significance of CT assessment in third molar surgery.

  18. A constrained conjugate gradient algorithm for computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, S.G.; Goodman, D.M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Image reconstruction from projections of x-ray, gamma-ray, protons and other penetrating radiation is a well-known problem in a variety of fields, and is commonly referred to as computed tomography (CT). Various analytical and series expansion methods of reconstruction and been used in the past to provide three-dimensional (3D) views of some interior quantity. The difficulties of these approaches lie in the cases where (a) the number of views attainable is limited, (b) the Poisson (or other) uncertainties are significant, (c) quantifiable knowledge of the object is available, but not implementable, or (d) other limitations of the data exist. We have adapted a novel nonlinear optimization procedure developed at LLNL to address limited-data image reconstruction problems. The technique, known as nonlinear least squares with general constraints or constrained conjugate gradients (CCG), has been successfully applied to a number of signal and image processing problems, and is now of great interest to the image reconstruction community. Previous applications of this algorithm to deconvolution problems and x-ray diffraction images for crystallography have shown the great promise.

  19. Review methods for image segmentation from computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Mamat, Nurwahidah; Rahman, Wan Eny Zarina Wan Abdul; Soh, Shaharuddin Cik [Faculty of Science Computer and Mathematics, Universiti Teknologi Mara Malaysia, 40450 Shah Alam Selangor (Malaysia); Mahmud, Rozi [Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 43400 Serdang Selangor (Malaysia)

    2014-12-04

    Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan.

  20. Pulmonary high-resolution computed tomography findings in nephropathia epidemica

    Energy Technology Data Exchange (ETDEWEB)

    Paakkala, Antti, E-mail: antti.paakkala@pshp.fi [Medical Imaging Centre, Tampere University Hospital, 33521 Tampere (Finland); Jaervenpaeae, Ritva, E-mail: ritva.jarvenpaa@pshp.fi [Medical Imaging Centre, Tampere University Hospital, 33521 Tampere (Finland); Maekelae, Satu, E-mail: satu.marjo.makela@uta.fi [Department of Internal Medicine, Tampere University Hospital, 33521 Tampere (Finland); Medical School, University of Tampere, 33521 Tampere (Finland); Huhtala, Heini, E-mail: heini.huhtala@uta.fi [School of Public Health, University of Tampere, 33521 Tampere (Finland); Mustonen, Jukka, E-mail: jukka.mustonen@uta.fi [Department of Internal Medicine, Tampere University Hospital, 33521 Tampere (Finland); Medical School, University of Tampere, 33521 Tampere (Finland)

    2012-08-15

    Purpose: To evaluate lung high-resolution computed tomography (HRCT) findings in patients with Puumala hantavirus-induced nephropathia epidemica (NE), and to determine if these findings correspond to chest radiograph findings. Materials and methods: HRCT findings and clinical course were studied in 13 hospital-treated NE patients. Chest radiograph findings were studied in 12 of them. Results: Twelve patients (92%) showed lung parenchymal abnormalities in HRCT, while only 8 had changes in their chest radiography. Atelectasis, pleural effusion, intralobular and interlobular septal thickening were the most common HRCT findings. Ground-glass opacification (GGO) was seen in 4 and hilar and mediastinal lymphadenopathy in 3 patients. Atelectasis and pleural effusion were also mostly seen in chest radiographs, other findings only in HRCT. Conclusion: Almost every NE patient showed lung parenchymal abnormalities in HRCT. The most common findings of lung involvement in NE can be defined as accumulation of pleural fluid and atelectasis and intralobular and interlobular septal thickening, most profusely in the lower parts of the lung. As a novel finding, lymphadenopathy was seen in a minority, probably related to capillary leakage and overall fluid overload. Pleural effusion is not the prominent feature in other viral pneumonias, whereas intralobular and interlobular septal thickening are characteristic of other viral pulmonary infections as well. Lung parenchymal findings in HRCT can thus be taken not to be disease-specific in NE and HRCT is useful only for scientific purposes.

  1. Bone changes of mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Un; Kim, Hyung Seop; Song, Ju Seop; Kim, Kyoung A; Koh, Kwang Joon [Chonbuk National Univ., Chonju (Korea, Republic of)

    2007-09-15

    To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibualr disorder (TMD) patients. 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra-and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Osteopathy (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior surface of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78{sub 0}.84), but interobserver agreement was fair (k=0.45). CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  2. Computed Tomography Findings of Pulmonary Mycobacterium simiae Infection

    Science.gov (United States)

    Baghizadeh, Ayeh; Farnia, Poopak

    2017-01-01

    Nontuberculous mycobacterial (NTM) pulmonary infections can be quite similar to tuberculosis, both clinically and radiologically. However, the treatment protocol is not similar. Mycobacterium simiae is a rare cause of NTM pulmonary infection. Herein, we aimed to evaluate and compare the computed tomography (CT) scan findings of M. simiae infection in lungs. For this reason, thirty-four patients (n = 34) with M. simiae lung infection were retrospectively evaluated. Diagnosis was confirmed by American Thoracic Society (ATS) guidelines and CT scans were reviewed in both lung and mediastinal windows. The average age of patients was 63 ± 14.54 years and 52.9% were male. The majority of patients had cough (91.2%) and sputum production (76.5%). Clinically, 41.2% of patients had previous history of TB (14/34), 38.2% had cardiac diseases (13/34), and 35.3% had diabetes mellitus (12/34). The most common CT findings in our study were nodular lesions (100%) and bronchiectasis (85.29%). Regarding the severity, grade I bronchiectasis was the most prevalent. Other prominent findings were tree-in-bud sign (88.2%), consolidation (52.94%), and lobar fibrosis and volume loss (67.6%). There was no significant zonal distribution of findings. In conclusion, nodular lesions and bronchiectasis are the most frequent features in CT scan of M. simiae pulmonary infection.

  3. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  4. Use of dentomaxillofacial cone beam computed tomography in dentistry

    Institute of Scientific and Technical Information of China (English)

    K?van?; Kamburo?lu

    2015-01-01

    Cone-beam computed tomography(CBCT) was developed and introduced specifically for dento-maxillofacial imaging. CBCT possesses a number of advantages over medical CT in clinical practice, such as lower effective radiation doses, lower costs, fewer space requirements,easier image acquisition, and interactive display modes such as mutiplanar reconstruction that are applicable to maxillofacial imaging. However, the disadvantages of CBCT include higher doses than two-dimensional imaging; the inability to accurately represent the internal structure of soft tissues and soft-tissue lesions; a limited correlation with Hounsfield Units for standardized quantification of bone density; and the presence of various types of image artifacts, mainly those produced by metal restorations. CBCT is now commonly used for a variety of purposes in oral implantology, dentomaxillofacial surgery, image-guided surgical procedures, endodontics, periodontics and orthodontics. CBCT applications provide obvious benefits in the assessment of dentomaxillofacial region, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  5. Digital Radiography and Computed Tomography (DRCT) Product Improvement Plan (PIP)

    Energy Technology Data Exchange (ETDEWEB)

    Tim Roney; Bob Pink; Karen Wendt; Robert Seifert; Mike Smith

    2010-12-01

    The Idaho National Laboratory (INL) has been developing and deploying x-ray inspection systems for chemical weapons containers for the past 12 years under the direction of the Project Manager for Non-Stockpile Chemical Materiel (PMNSCM). In FY-10 funding was provided to advance the capabilities of these systems through the DRCT (Digital Radiography and Computed Tomography) Product Improvement Plan (PIP), funded by the PMNSCM. The DRCT PIP identified three research tasks; end user study, detector evaluation and DRCT/PINS integration. Work commenced in February, 2010. Due to the late start and the schedule for field inspection of munitions at various sites, it was not possible to spend sufficient field time with operators to develop a complete end user study. We were able to interact with several operators, principally Mr. Mike Rowan who provided substantial useful input through several discussions and development of a set of field notes from the Pueblo, CO field mission. We will be pursuing ongoing interactions with field personnel as opportunities arise in FY-11.

  6. Cone beam computed tomography findings of impacted upper canines

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva Santos, Ludmilla Mota [Dept. of Endodontics, Aracatuba Dental School, Paulista State University, Aracatuba(Brazil); Bastos, Luana Costa; Da Silva, Silvio Jose Albergaria; Campos, Paulo Sergio Flores [School of Dentistry, Federal University of Bahia, Salvador (Brazil); Oliveira Santos, Christiano [Dept. of Stomatology, Oral Public Health, and Forensic Dentistry, School of Dentistry, University of Sao Paulo, Ribeirao Preto (Brazil); Neves, Frederico Sampaio [Dept. of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba (Brazil)

    2014-12-15

    To describe the features of impacted upper canines and their relationship with adjacent structures through three-dimensional cone-beam computed tomography (CBCT) images. Using the CBCT scans of 79 upper impacted canines, we evaluated the following parameters: gender, unilateral/bilateral occurrence, location, presence and degree of root resorption of adjacent teeth (mild, moderate, or severe), root dilaceration, dental follicle width, and presence of other associated local conditions. Most of the impacted canines were observed in females (56 cases), unilaterally (51 cases), and at a palatine location (53 cases). Root resorption in adjacent teeth and root dilaceration were observed in 55 and 47 impacted canines, respectively. In most of the cases, the width of the dental follicle of the canine was normal; it was abnormally wide in 20 cases. A statistically significant association was observed for all variables, except for root dilaceration (p=0.115) and the side of impaction (p=0.260). Root resorption of adjacent teeth was present in most cases of canine impaction, mostly affecting adjacent lateral incisors to a mild degree. A wide dental follicle of impacted canines was not associated with a higher incidence of external root resorption of adjacent teeth.

  7. Value of Multidetector Computed Tomography in Assessing Blunt Multitrauma Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ahvenjaervi, L.; Mattila, L.; Ojala, R.; Tervonen, O. [Oulu Univ. Hospital (Finland). Dept. of Diagnostic Radiology

    2005-04-01

    Purpose: To find out if multidetector computed tomography (MDCT), using a dedicated trauma protocol, provides sufficient diagnostic information of the injuries of blunt multitrauma patients to enable the planning of treatment for all body compartments. Material and Methods: One-hundred-and-thirty-three patients exposed to high-energy trauma were referred and scanned with the standardized MDCT multitrauma protocol. The imaging protocol consisted of axial scanning of the head and helical scanning of the facial bones, cervical spine, thorax, abdomen, and pelvis. The scanning times were 12 s for the head, 19-21 s for the facial bones and cervical spine (1 mm collimation), and 32-50 s for the thorax, abdomen, and pelvis (2 mm collimation). One-hundred-and-forty milliliters of non-iodinated contrast material (300 mg I/ml) was administered intravenously at 3 ml/s. Results: Ninety-nine of the patients (74%) had at least one finding consistent with trauma. The most frequent findings were in the thorax in 58 patients (44%). Nineteen false-negative findings and two false-positive findings were made. The overall sensitivity of MDCT was 94%, specificity 100%, and accuracy 97%. Conclusion: MDCT is accurate in the assessment of blunt multitrauma patients. The decision to treat the patient can be made on the basis of MDCT with a reasonable level of certainty.

  8. Multidetector Computed Tomography of Cervical Spine Fractures in Ankylosing Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toeoeloe Trauma Center (Finland). Dept. of Radiology

    2004-11-01

    Purpose: To analyze multidetector computed tomography (MDCT) cervical spine findings in trauma patients with advanced ankylosing spondylitis (AS). Material and Methods: Using PACS, 2282 cervical spine MDCT examinations requested by emergency room physicians were found during a period of 3 years. Of these patients, 18 (16 M, aged 41-87, mean 57 years) had advanced AS. Primary imaging included radiography in 12 and MRI in 11 patients. Results: MDCT detected one facet joint subluxation and 31 fractures in 17 patients: 14 transverse fractures, 8 spinous process fractures, 2 Jefferson's fractures, 1 type I and 2 type II odontoid process fractures, and 1 each: atlanto-occipital joint fracture and C2 laminar fracture plus isolated transverse process and facet joint fractures. Radiographs detected 48% and MRI 60% of the fractures. MRI detected all transverse and odontoid fractures, demonstrating spinal cord abnormalities in 72%. Conclusion: MDCT is superior to plain radiographs or MRI, showing significantly more injuries and yielding more information on fracture morphology. MRI is valuable, however, in evaluating the spinal cord and soft-tissue injuries. Fractures in advanced AS often show an abnormal orientation and are frequently associated with spinal cord injuries. In these patients, for any suspected cervical spine injuries, MDCT is therefore the imaging modality of choice.

  9. Computed tomography dose optimisation in cystic fibrosis:A review

    Institute of Scientific and Technical Information of China (English)

    Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O’Neill; Kevin Murphy; Owen J O’Connor; Michael Maher

    2016-01-01

    Cystic fibrosis(CF)is the most common autosomal recessive disease of the Caucasian population worldwide,with respiratory disease remaining the most relevant source of morbidity and mortality.Computed tomography(CT)is frequently used for monitoring disease complications and progression.Over the last fifteen years there has been a six-fold increase in the use of CT,which has lead to a growing concern in relation to cumulative radiation exposure.The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality,but fulfil the requirements of a diagnostic quality CT.Dose-optimisation,particularly in CT,is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 m Sv,a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation.This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  10. Image quality of mixed convolution kernel in thoracic computed tomography.

    Science.gov (United States)

    Neubauer, Jakob; Spira, Eva Maria; Strube, Juliane; Langer, Mathias; Voss, Christian; Kotter, Elmar

    2016-11-01

    The mixed convolution kernel alters his properties geographically according to the depicted organ structure, especially for the lung. Therefore, we compared the image quality of the mixed convolution kernel to standard soft and hard kernel reconstructions for different organ structures in thoracic computed tomography (CT) images.Our Ethics Committee approved this prospective study. In total, 31 patients who underwent contrast-enhanced thoracic CT studies were included after informed consent. Axial reconstructions were performed with hard, soft, and mixed convolution kernel. Three independent and blinded observers rated the image quality according to the European Guidelines for Quality Criteria of Thoracic CT for 13 organ structures. The observers rated the depiction of the structures in all reconstructions on a 5-point Likert scale. Statistical analysis was performed with the Friedman Test and post hoc analysis with the Wilcoxon rank-sum test.Compared to the soft convolution kernel, the mixed convolution kernel was rated with a higher image quality for lung parenchyma, segmental bronchi, and the border between the pleura and the thoracic wall (P kernel, the mixed convolution kernel was rated with a higher image quality for aorta, anterior mediastinal structures, paratracheal soft tissue, hilar lymph nodes, esophagus, pleuromediastinal border, large and medium sized pulmonary vessels and abdomen (P kernel cannot fully substitute the standard CT reconstructions. Hard and soft convolution kernel reconstructions still seem to be mandatory for thoracic CT.

  11. Predicting Neck Abscess with Contrast-Enhanced Computed Tomography

    Directory of Open Access Journals (Sweden)

    Melisa Lim Seer Yee

    2014-01-01

    Full Text Available Neck abscesses are difficult to diagnose and treat. Currently, contrast-enhanced computed tomography (CECT is the imaging modality of choice. The study aims to determine the predictive value of CECT findings in diagnosing neck abscess, causes of neck abscess and the most common neck space involved in the local population. 84 consecutive patients clinically suspected to have neck abscess who underwent CECT and surgical confirmation of pus were included. Demographic and clinical data were recorded. 75 patients were diagnosed as having neck abscess on CECT; out of those 71 patients were found to have pus. Overall CECT findings were found to have a high sensitivity (98.6% and positive predictive value (PPV (94.7% but lower specificity (67.2% in diagnosing neck abscess. The CECT diagnostic criterion with the highest PPV is the presence of rim irregularity (96%. The most common deep neck space involved is the submandibular compartment, which correlates with the finding that odontogenic cause was the most common identifiable cause of abscess in the study population. Thus, in a patient clinically suspected of having neck abscess, CECT findings of a hypodense mass with rim irregularity are helpful in confirming the diagnosis and guiding clinical management.

  12. Oblique reconstruction of the cruciate ligaments on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Hidetoshi; Nishino, Koshi; Koga, Masayuki; Kitakata, Akira; Deya, Keizo; Nakagawa, Hiroto

    1984-12-01

    Optimal positioning where the entire longitudinal axis of the cruciate ligaments could be demonstrated on computed tomography was discovered by using an amputated knee and was applied clinically. To demonstrate the anterior cruciate ligament, the patient was positioned on the table with the hip flexed, abducted, externally rotated and knee flexed at a 110-140 degrees angle. For the posterior cruciate ligament, the patient was placed in a prone position on the table with the knee flexed at a 50 degrees angle. These positions, especially the one for the anterior cruciate ligament, were difficult for some patients with gonalgia or limited range of motion. Reconstruction in the oblique planes was studied for those patients by using an amputated knee and quasi-ligament made of gum. Clinically, an axial image was obtained by the simple position of the patient lying prone on the table with knee extended. Oblique reconstruction was made from the axial images and this reconstructed image also demonstrated the entire longitudinal axis of the ligament. The rupture of the cruciate ligaments could be assessed by the reconstructed image in the oblique plane. (author).

  13. Soft tissue discrimination ex vivo by dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zachrisson, H., E-mail: helene.zachrisson@lio.s [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Engstroem, E. [Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Engvall, J.; Wigstroem, L. [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Clinical Physiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Smedby, O.; Persson, A. [Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden); Radiology, Department of Medical and Health Sciences (IMH), Linkoeping University, Linkoeping University Hospital, SE-581 85 Linkoeping (Sweden)

    2010-08-15

    Purpose: Dual Energy Computed Tomography (DECT) may provide additional information about the chemical composition of tissues compared to examination with a single X-ray energy. The aim of this in vitro study was to test whether combining two energies may significantly improve the detection of soft tissue components commonly present in arterial plaques. Methods: Tissue samples of myocardial and psoas muscle, venous and arterial thrombus as well as fat from different locations were scanned using a SOMATOM Definition Dual Source CT system (Siemens AG, Medical Solutions, Forchheim, Germany) with simultaneous tube voltages of 140 and 80 kV. The attenuation (Hounsfield units, HU) at 80 and 140 kV was measured in representative regions of interest, and the association between measured HU values and tissue types was tested with logistic regression. Results: The combination of two energy levels (80 and 140 kV) significantly improved (p < 0.001) the ability to correctly classify venous thrombus vs arterial thrombus, myocardium or psoas; arterial thrombus vs myocardium or psoas; myocardium vs psoas; as well as the differentiation between fat tissue from various locations. Single energy alone was sufficient for distinguishing fat from other tissues. Conclusion: DECT offers significantly improved in vitro differentiation between soft tissues occurring in plaques. If this corresponds to better tissue discrimination in vivo needs to be clarified in future studies.

  14. The application of computed tomography in wound ballistics research

    Science.gov (United States)

    Tsiatis, Nick; Moraitis, Konstantinos; Papadodima, Stavroula; Spiliopoulou, Chara; Kelekis, Alexis; Kelesis, Christos; Efstathopoulos, Efstathios; Kordolaimi, Sofia; Ploussi, Agapi

    2015-09-01

    In wound ballistics research there is a relationship between the data that characterize a bullet and the injury resulted after shooting when it perforates the human body. The bullet path in the human body following skin perforation as well as the damaging effect cannot always be predictable as they depend on various factors such as the bullet's characteristics (velocity, distance, type of firearm and so on) and the tissue types that the bullet passes through. The purpose of this presentation is to highlight the contribution of Computed Tomography (CT) in wound ballistics research. Using CT technology and studying virtual “slices” of specific areas on scanned human bodies, allows the evaluation of density and thickness of the skin, the subcutaneous tissue, the muscles, the vital organs and the bones. Density data taken from Hounsfield units can be converted in g/ml by using the appropriate software. By evaluating the results of this study, the anatomy of the human body utilizing ballistic gel will be reproduced in order to simulate the path that a bullet follows. The biophysical analysis in wound ballistics provides another application of CT technology, which is commonly used for diagnostic and therapeutic purposes in various medical disciplines.

  15. Comparison of different additive manufacturing methods using computed tomography

    Directory of Open Access Journals (Sweden)

    Paras Shah

    2016-11-01

    Full Text Available Additive manufacturing (AM allows for fast fabrication of three dimensional objects with the use of considerably less resources, less energy consumption and shorter supply chain than would be the case in traditional manufacturing. AM has gained significance due to its cost effective method which boasts the ability to produce components with a previously unachievable level of geometric complexity in prototyping and end user industrial applications, such as aerospace, automotive and medical industries. However these processes currently lack reproducibility and repeatability with some ‘prints’ having a high probability of requiring rework or even scrapping due to out of specification or high porosity levels, leading to failure due to structural stresses. It is therefore imperative that robust quality systems be implemented such that the waste level of these processes can be significantly decreased. This study presents an artefact that is optimised for characterisation of form using computed tomography (CT with representative geometric dimensioning and tolerancing features and internal channels and structures comparable to cooling channels in heat exchangers. Furthermore the optimisation of the CT acquisition conditions for this artefact are presented in light of feature dimensions and form analysis. This paper investigates the accuracy and capability of CT measurements compared with reference measurements from coordinate measuring machine (CMM, as well as focus on the evaluation of different AM methods.

  16. Computed tomography of the thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Tanimura, Shigeo; Sakaguchi, Kozo; Tomoyasu, Hiroshi; Banba, Jiro; Masaki, Mikio; Kurosaki, Atsuko; Matsushita, Hisashi [Toranomon Hospital, Tokyo (Japan)

    1995-01-01

    Comparison of preoperative CT diagnosis and histopathological diagnosis for the thymus were studied in 39 patients with myasthenia gravis. The patients consisted of 10 patients with thymoma and 29 without thymoma confirmed at the operation. CT diagnosis was 11 thymomas, 18 thymic hyperplasias and 10 normal thymuses. Eleven thymomas revealed histopathologically 9 thymomas, one follicular lymphoid hyperplasia (FLH) and one involved thymus. Out of 18 thymic hyperplasias 15 cases were FLH and 3 involved thymus. There were 5 involved thymuses, 4 FLHs and one thymoma in the 10 normal thymuses on CT. The finding of `reticular pattern`, many small nodules scattered reticularly in the thymus, in computed tomography could be regarded as a sign suggesting FLH of the thymus. The accuracy of this finding of CT was 83% for FLH. The finding of thymoma on CT revealed 82% of the accuracy. Therefore, CT was very useful in the diagnosis of the localization of the thymoma but not for the diagnosis of FLH of the thymus. Nevertheless the finding of `reticular pattern` on CT was helpful in the diagnosis of FLH. (author).

  17. Computed tomography in the imaging of colonic diverticulitis

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, O.; Geoghegan, T.; O' Riordain, D.S.; Lyburn, I.D.; Torreggiani, W.C. E-mail: william.torreggiani@amnch.ie

    2004-11-01

    Colonic diverticulitis occurs when diverticula within the colon become infected or inflamed. It is becoming an increasingly common cause for hospital admission, particularly in western society, where it is linked to a low fibre diet. Symptoms of diverticulitis include abdominal pain, diarrhoea and pyrexia, however, symptoms are often non-specific and the clinical diagnosis may be difficult. In addition, elderly patients and those taking corticosteroids may have limited findings on physical examination, even in the presence of severe diverticulitis. A high index of suspicion is required in such patients in order to avoid a significant delay in arriving at the correct diagnosis. Imaging plays an important role in establishing an early and correct diagnosis. In the past, contrast enema studies were the principal imaging test used to make the diagnosis. However, such studies lack sensitivity and have limited success in identifying abscesses that may require drainage. Conversely computed tomography (CT) is both sensitive and specific in making a diagnosis of diverticulitis. In addition, it is the imaging technique of choice in depicting complications such as perforation, abscess formation and fistulae. CT-guided drainage of diverticular abscesses helps to reduce sepsis and to permit a one-stage, rather than two-stage, surgical operation. The purpose of this review article is to discuss the role of CT in the imaging of diverticulitis, describe the CT imaging features and complications of this disease, as well as review the impact and rationale of CT imaging and intervention in the overall management of patients with diverticulitis.

  18. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  19. Frontal sinus parameters in computed tomography and sex determination.

    Science.gov (United States)

    Akhlaghi, Mitra; Bakhtavar, Khadijeh; Moarefdoost, Jhale; Kamali, Artin; Rafeifar, Shahram

    2016-03-01

    The frontal sinus is a sturdy part of the skull that is likely to be retrieved for forensic investigations. We evaluated frontal sinus parameters in paranasal sinus computed tomography (CT) images for sex determination. The study was conducted on 200 normal paranasal sinus CT images of 100 men and 100 women of Persian origin. We categorized the studied population into three age groups of 20-34, 35-49 and ⩾ 50 years. The number of partial septa in the right frontal sinus and the maximum height and width were significantly different between the two sexes. The highest precision for sex determination was for the maximum height of the left frontal sinus (61.3%). In the 20-34 years age-group, height and width of the frontal sinus were significantly different between the two sexes and the height of the left sinus had the highest precision (60.8%). In the 35-49 years age-group, right anterior-posterior diameter had a sex determination precision of 52.3%. No frontal sinus parameter reached a statistically significant level for sex determination in the ⩾ 50 years age-group. The number of septa and scallopings were not useful in sex determination. Frontal sinus parameters did not have a high precision in sex determination among Persian adults.

  20. Direct reconstruction of enhanced signal in computed tomography perfusion

    Science.gov (United States)

    Li, Bin; Lyu, Qingwen; Ma, Jianhua; Wang, Jing

    2016-04-01

    High imaging dose has been a concern in computed tomography perfusion (CTP) as repeated scans are performed at the same location of a patient. On the other hand, signal changes only occur at limited regions in CT acquired at different time points. In this work, we propose a new reconstruction strategy by effectively utilizing the initial phase high-quality CT to reconstruct the later phase CT acquired with a low-dose protocol. In the proposed strategy, initial high-quality CT is considered as a base image and enhanced signal (ES) is reconstructed directly by minimizing the penalized weighted least-square (PWLS) criterion. The proposed PWLS-ES strategy converts the conventional CT reconstruction into a sparse signal reconstruction problem. Digital and anthropomorphic phantom studies were performed to evaluate the performance of the proposed PWLS-ES strategy. Both phantom studies show that the proposed PWLS-ES method outperforms the standard iterative CT reconstruction algorithm based on the same PWLS criterion according to various quantitative metrics including root mean squared error (RMSE) and the universal quality index (UQI).