WorldWideScience

Sample records for cerebral computed tomography

  1. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  2. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  3. Computed tomography of cerebral palsy

    International Nuclear Information System (INIS)

    Seventy patients who had suffered from severe damages in the brain in their early lives were examined using a CT scanner, DELTA-25. The results are summerized as follows: 1. CT findings of the brain were classified into four groups; (1) low density in 11 cases, (2) atrophy in 23, (3) hydrocephalus in 12, and (4) no findings in 24. 2. The low density in the CT finding was assumed as cystic degeneration due to circulatory disturbance in the cerebral hemispheres in their early developmental stages. 3. The ''acerebrate'' state denotes no or little development in mental and motor functions which is attributed to a severe damage in the developing brain. According to the CT findings, the ''acerebrate'' state was resulted from extensive destruction in the greater part of both hemispheres. (author)

  4. Computed tomography in spastic cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, H.; Taudorf, K.; Melchior, J.C.

    1982-09-01

    Eighty-three children with spastic cerebral palsy (CP) were examined with cranial CT. In 56 cases the CT findings were abnormal. The most frequent abnormality was atrophy, present in 44 patients. The frequency of pathologic CT increased with severity of the CP. Patients with CP of postnatal aetiology more often had abnormal CT than patients with other known causes. Pathologic CT findings were seen more often in patients with seizures than in patients without. Infarctions and hemiatrophy were much more frequent in patients with hemiplegia than in patients with other types of spastic CP. A special kind of central atrophy, called isolated atrophy around the cella media, is described. This condition was seen in 20% of cases, most often in hemi- and paraplegic patients. Early infarctions in the border areas between the vascular territories of the internal carotid and the posterior cerebral artery may be the reason for this kind of atrophy.

  5. Computed tomography in spastic cerebral palsy

    International Nuclear Information System (INIS)

    Eigthy-three children with spastic cerebral plays (CP) were examined with cranial CT. In 56 cases the CT findings were abnormal. The most frequent abnormality was atrophy, present in 44 patients. The frequency of pathologic CT increased with severity of the CP. Patients with CP of postnatal aetiology more often had abnormal CT than patients with other known causes. Pathologic CT findings were seen more often in patients with seizures than in patients without. Infarctions and hemiatrophy were much more frequent in patients with hemiplegia than in patients with other types of spastic CP. A special kind of central atrophy, called isolated atrophy around the cella media, is described. This condition was seen in 20% of cases, most often in hemi- and paraplegic patients. Early infarctions in the border areas between the vasular territories of the internal carotid and the posterior cerebral artery may be the reason for this kind of atrophy. (orig.)

  6. Age-related cerebral white matter changes on computed tomography

    International Nuclear Information System (INIS)

    Changes of cerebral white matter on computed cranial tomography related to aging were studied in 70 subjects aged 30 to 94 years. The subjects had no histories of cerebrovascular accidents and no abnormalities in the central nervous system were shown by physical examinations and CT scans. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39cm2) in the bilateral thalamus and twelve areas of deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size and cranial bone CT numbers on the brain CT numbers. We also studied the association between brain CT numbers and brain atrophy, hypertension, diabetes mellitus. CT numbers of frontal white matter surrounding anterior horns decreased with aging in 70 subjects aged 30 to 94 years. No significant correlation between age and brain CT numbers was found in any other region by multivariate analysis, because of the prominent effect of cranial bone CT numbers on brain CT numbers. Although no age-related changes of white matter CT numbers was found in 41 subjects aged 30 to 65 years, there were significant negative correlations between age and white matter CT numbers at all regions in 29 subjects aged 66 to 94 years. Brain atrophy was associated with brain CT numbers. No association was found for hypertension or diabetes mellitus. Brain CT numbers decreased with aging even in neurologically healthy persons in older age. Brain CT numbers also decreased as cerebral atrophy advanced. (author)

  7. Age-related cerebral white matter changes on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Kouichi; Tsunematsu, Tokugoro

    1989-01-01

    Changes of cerebral white matter on computed cranial tomography related to aging were studied in 70 subjects aged 30 to 94 years. The subjects had no histories of cerebrovascular accidents and no abnormalities in the central nervous system were shown by physical examinations and CT scans. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39cm/sup 2/) in the bilateral thalamus and twelve areas of deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size and cranial bone CT numbers on the brain CT numbers. We also studied the association between brain CT numbers and brain atrophy, hypertension, diabetes mellitus. CT numbers of frontal white matter surrounding anterior horns decreased with aging in 70 subjects aged 30 to 94 years. No significant correlation between age and brain CT numbers was found in any other region by multivariate analysis, because of the prominent effect of cranial bone CT numbers on brain CT numbers. Although no age-related changes of white matter CT numbers was found in 41 subjects aged 30 to 65 years, there were significant negative correlations between age and white matter CT numbers at all regions in 29 subjects aged 66 to 94 years. Brain atrophy was associated with brain CT numbers. No association was found for hypertension or diabetes mellitus. Brain CT numbers decreased with aging even in neurologically healthy persons in older age. Brain CT numbers also decreased as cerebral atrophy advanced. (author).

  8. Studies of cerebrovascular lesion by computer tomography, cerebral scintigrapy and EEG in longitudinal section

    International Nuclear Information System (INIS)

    A long-term follow-up of an intracerebral hemorrhage by computer tomography, cerebral scintigraphy and EEG is reported. In the acute phase of the cerebral hemorrhage, EEG, computer tomography and scintigraphy are equally useful diagnostic techniques. In the recovery phase of the hemorrhage only the results of computer tomography fitted with the clinical status of the patients. In this phase of hemorrhage, scintigraphy was less sensitive in the following of the regeneration of cerebral circulation than in the previous phases. (L.G.)

  9. Comparison of Cerebral Oxygen Saturation and Cerebral Perfusion Computed Tomography in Cerebral Blood Flow in Patients with Brain Injury.

    Science.gov (United States)

    Trofimov, Alexey O; Kalentiev, George; Voennov, Oleg; Grigoryeva, Vera

    2016-01-01

    The purpose of this study was to determine the relationship between cerebral tissue oxygen saturation and cerebral blood volume in patients with traumatic brain injury. Perfusion computed tomography of the brain was performed in 25 patients with traumatic brain injury together with simultaneous SctO2 level measurement using cerebral near-infrared oxymetry. The mean age of the injured persons was 34.5±15.6 years (range 15-65); 14 men, 11 women. The Injury Severity Score (ISS) values were 44.4±9.7 (range 25-81). The Glasgow Coma Score (GCS) mean value before the study was 10.6±2.1 (range 5-13). SctO2 ranged from 51 to 89%, mean 62±8.2%. Cerebral blood volume (CBV) values were 2.1±0.67 ml/100 g (min 1.1; max 4.3 ml/100 g). Cerebral blood flow (CBF) was 31.99±13.6 ml/100 g×min. Mean transit time (MTT) values were 5.7±4.5 s (min 2.8; max 34.3 s). The time to peak (TTP) was 22.2±3.1 s. A statistically significant correlation was found between SctO2 level and cerebral blood volume (CBV) level (R=0.9; pperfusion.

  10. Selective value of computed tomography of the brain in Cerebritis due to systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Gaylis, N.B.; Altman, R.D.; Ostrov, S.; Quencer, R. (Miami Univ., FL (USA). School of Medicine)

    Systemic lupus erythematosus (SLE) and steroid effects on the brain were measured by computed tomography (CT). Of 14 patients with SLE cerebritis, 10 (71%) had marked cortical atrophy and 4 (29%) minimal atrophy. None were normal by CT. Controls included 22 patients with SLE without cerebritis receiving cortiocosteroids; this group had normal CT scans in 16 (73%) and minimal cortical atrophy in the remaining 6 (27%). Follow-up CT on 5 patients with cerebritis was unchanged. CT of the brain is a minimally invasive technique for documenting SLE cerebritis. CT may also help differentiate cerebritis from the neuropsychiatric side effects of corticosteroids.

  11. The selective value of computed tomography of the brain in Cerebritis due to systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Systemic lupus erythematosus (SLE) and steroid effects on the brain were measured by computed tomography (CT). Of 14 patients with SLE cerebritis, 10 (71%) had marked cortical atrophy and 4 (29%) minimal atrophy. None were normal by CT. Controls included 22 patients with SLE without cerebritis receiving cortiocosteroids; this group had normal CT scans in 16 (73%) and minimal cortical atrophy in the remaining 6 (27%). Follow-up CT on 5 patients with cerebritis was unchanged. CT of the brain is a minimally invasive technique for documenting SLE cerebritis. CT may also help differentiate cerebritis from the neuropsychiatric side effects of corticosteroids

  12. Value of three-dimensional computed tomography in screening cerebral aneurysms

    International Nuclear Information System (INIS)

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  13. Value of three-dimensional computed tomography in screening cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Tamaki; Sugiura, Yusuke; Suzuki, Atsushi; Yamagata, Yoshitaka [Hyogo Medical Coll. (Japan)

    1997-10-01

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  14. Early cerebral circulatory disturbance in patients suffering subarachnoid hemorrhage prior to the delayed cerebral vasospasm stage. Xenon computed tomography and perfusion computed tomography study

    International Nuclear Information System (INIS)

    Subarachnoid hemorrhage (SAH) causes dynamic changes in cerebral blood flow (CBF), and results in delayed ischemia due to vasospasm, and early perfusion deficits before delayed cerebral vasospasm (CVS). The present study examined the severity of cerebral circulatory disturbance during the early phase before delayed CVS and whether it can be used to predict patient outcome. A total of 94 patients with SAH underwent simultaneous xenon computed tomography (CT) and perfusion CT to evaluate cerebral circulation on Days 1-3. Cerebral blood flow (CBF) was measured using xenon CT and the mean transit time (MTT) using perfusion CT and calculated cerebral blood volume (CBV). Outcome was evaluated with the Glasgow Outcome Scale (good recovery [GR], moderate disability [MD], severe disability [SD], vegetative state [VS], or death [D]). Hunt and Hess (HH) grade II patients displayed significantly higher CBF and lower MTT than HH grade IV and V patients. HH grade III patients displayed significantly higher CBF and lower MTT than HH grade IV and V patients. Patients with favorable outcome (GR or MD) had significantly higher CBF and lower MTT than those with unfavorable outcome (SD, VS, or D). Discriminant analysis of these parameters could predict patient outcome with a probability of 74.5%. Higher HH grade on admission was associated with decreased CBF and CBV and prolonged MTT. CBF reduction and MTT prolongation before the onset of delayed CVS might influence the clinical outcome of SAH. These parameters are helpful for evaluating the severity of SAH and predicting the outcomes of SAH patients. (author)

  15. Cerebral computed tomography in men with acquired immunodeficiency syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brun, B.; Boesen, F.; Gerstoft, J.; Nielsen, J.O.; Praestholm, J.

    Cerebral CT scannings were performed in 19 homosexual men with the acquired immunodeficiency syndrome (AIDS). Nearly half of them (9 patients) had cortical atrophy. Three patients with toxoplasmosis had cerebral pathology, in two of them with ring enhancement while the third had an ill-defined nonspecific lesion with slight heterogeneous enhancement without ring formation. Two patients with multifocal leucoencephalopathy and non-Hodgkin's lymphoma, respectively, presented non-enhancing, low attenuating lesions at CT.

  16. A study of cerebral perfusion using single photon emission computed tomography in neonates with brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, J.; Contantinesco, A.; Brunot, B.; Messer, J. (Hospital Universitaire de Strasbourg (France))

    1994-03-01

    In this study the authors used a single photon emission computed tomography technique (SPECT) with radiolabelled [sup 99m]Tc HMPAO to assess cerebral perfusion in newborn infants with documented cerebral lesions and to determine to what extent brain SPECT might be useful in the neonatal period. A total of 15 newborn infants with the following cerebral pathologies were enrolled: severe parietal bilateral periventricular leucomalacia; moderate parietal bilateral PVL; intraventricular haemorrhage grade II with unilateral parietal parenchymal extension; cerebral infarction in the zone of middle cerebral artery; and post-haemorrhagic hydrocephalus. Follow-up was available in all infants. Alterations in cerebral perfusion were seen in only 12 of 15 infants and at the location of severe PVL, PE and CI. It was noted that the regions of diminished perfusion extended beyond the apparent extent of cerebral pathology delineated by ultrasound or magnetic resonance imaging. Markedly diminished perfusion was seen in one infant with hydrocephalus, which recovered following placement of ventriculo-peritoneal shunt. Regarding outcome, SPECT data failed to provide additional information than that of neuroradiological investigations. It is concluded that the use of SPECT, under these conditions, to assess alteration of cerebral perfusion in the neonatal period will not provide any additional information than that of neuroradiological investigations. 17 refs., 3 figs., 1 tab.

  17. Computer tomography in the diagnosis of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Marinsek-Cicin-Sain, V.; Besenski, N.; Jelicic, I.; Broz, R.

    1984-01-01

    Cerebral cystiscercosis was diagnosed in 16 patients by CT, both before and after contrast injection. In six patients the findings were confirmed at operation and histologically. In ten patients, the diagnosis was supported by typical findings on conventional radiographs of the thighs, calves and skull. The CT findings permitted classification of the patients into three types of disease.

  18. Computer tomography in the diagnosis of cerebral cysticercosis

    International Nuclear Information System (INIS)

    Cerebral cystiscercosis was diagnosed in 16 patients by CT, both before and after contrast injection. In six patients the findings were confirmed at operation and histologically. In ten patients, the diagnosis was supported by typical findings on conventional radiographs of the thighs, calves and skull. The CT findings permitted classification of the patients into three types of disease. (orig.)

  19. Study of regional cerebral metabolic rate of glucose with positron emission computed tomography in Alzheimer's disease

    International Nuclear Information System (INIS)

    Using positron emission computed tomography with F-18 fluoro-D-deoxyglucose, regional cerebral metabolic rate of glucose (rCMRglc) was measured in 8 patients with Alzheimer's disease and 3 healthy volunteers. A decreased rCMRglc was observed in the widespread cortex and basal ganglia of the cerebrum, but not observed in white matter, thalamus, and cerebellum. There was no bilateral difference. rCMRglc was the lowest in the parietal lobe, followed by the temporal lobe and the curvature of the frontal lobe. A decrease in rCMRglu was relatively mild in the inner part of the frontal lobe, primary sensory and motor area of the cerebral cortex, and cerebral basilar ganglia. Alzheimer's disease proved to be characterized by severe glucose metabolic disorder in the association area of the bilateral cerebral cortices. The degree of metabolic disorder was correlated with the degree of dementia in the outer part of the left frontal lobe and the curvature of the cerebral cortex. (Namekawa, K.)

  20. Assessing regional cerebral blood flow in depression using 320-slice computed tomography.

    Directory of Open Access Journals (Sweden)

    Yiming Wang

    Full Text Available While there is evidence that the development and course of major depressive disorder (MDD symptomatology is associated with vascular disease, and that there are changes in energy utilization in the disorder, the extent to which cerebral blood flow is changed in this condition is not clear. This study utilized a novel imaging technique previously used in coronary and stroke patients, 320-slice Computed-Tomography (CT, to assess regional cerebral blood flow (rCBF in those with MDD and examine the pattern of regional cerebral perfusion. Thirty nine participants with depressive symptoms (Hamilton Depression Rating Scale 24 (HAMD24 score > 20, and Self-Rating Depression Scale (SDS score > 53 and 41 healthy volunteers were studied. For all subjects, 3 ml of venous blood was collected to assess hematological parameters. Transcranial Doppler (TCD ultrasound was utilized to measure parameters of cerebral artery rCBFV and analyse the Pulsatility Index (PI. 16 subjects (8 =  MDD; 8 =  healthy also had rCBF measured in different cerebral artery regions using 320-slice CT. Differences among groups were analyzed using ANOVA and Pearson's tests were employed in our statistical analyses. Compared with the control group, whole blood viscosity (including high\\middle\\low shear rateand hematocrit (HCT were significantly increased in the MDD group. PI values in different cerebral artery regions and parameters of rCBFV in the cerebral arteries were decreased in depressive participants, and there was a positive relationship between rCBFV and the corresponding vascular rCBF in both gray and white matter. rCBF of the left gray matter was lower than that of the right in MDD. Major depression is characterized by a wide range of CBF impairments and prominent changes in gray matter blood flow. 320-slice CT appears to be a valid and promising tool for measuring rCBF, and could thus be employed in psychiatric settings for biomarker and treatment response purposes.

  1. Racking the brain: Detection of cerebral edema on postmortem computed tomography compared with forensic autopsy

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Nicole [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Ampanozi, Garyfalia; Schweitzer, Wolf; Ross, Steffen G.; Gascho, Dominic [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Ruder, Thomas D. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic, Interventional and Pediatric Radiology, University Hospital of Bern, Freiburgstrasse, 3010 Bern (Switzerland); Thali, Michael J. [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.uzh.ch [Institute of Forensic Medicine, Virtopsy, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2015-04-15

    Graphical abstract: -- Highlights: •Postmortem swelling of the brain is a typical finding on PMCT and occurs concomitant with potential antemortem or agonal brain edema. •Cerebral edema despite normal postmortem swelling is indicated by narrowed temporal horns and symmetrical herniation of the cerebral tonsils on PMCT. •Cases with intoxication or asphyxia demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units) and a ratio >1.58 between the gray and white matter. •The Hounsfield measurements of the white and gray matter help to determine the cause of death in cases of intoxication or asphyxia. -- Abstract: Purpose: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. Materials and methods: The study collective included a total of 109 cases (n = 109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. Results: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p < 0.001). There was a significant difference (p < 0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to

  2. Racking the brain: Detection of cerebral edema on postmortem computed tomography compared with forensic autopsy

    International Nuclear Information System (INIS)

    Graphical abstract: -- Highlights: •Postmortem swelling of the brain is a typical finding on PMCT and occurs concomitant with potential antemortem or agonal brain edema. •Cerebral edema despite normal postmortem swelling is indicated by narrowed temporal horns and symmetrical herniation of the cerebral tonsils on PMCT. •Cases with intoxication or asphyxia demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units) and a ratio >1.58 between the gray and white matter. •The Hounsfield measurements of the white and gray matter help to determine the cause of death in cases of intoxication or asphyxia. -- Abstract: Purpose: The purpose of this study was to compare postmortem computed tomography with forensic autopsy regarding their diagnostic reliability of differentiating between pre-existing cerebral edema and physiological postmortem brain swelling. Materials and methods: The study collective included a total of 109 cases (n = 109/200, 83 male, 26 female, mean age: 53.2 years) and were retrospectively evaluated for the following parameters (as related to the distinct age groups and causes of death): tonsillar herniation, the width of the outer and inner cerebrospinal fluid spaces and the radiodensity measurements (in Hounsfield Units) of the gray and white matter. The results were compared with the findings of subsequent autopsies as the gold standard for diagnosing cerebral edema. p-Values <0.05 were considered statistically significant. Results: Cerebellar edema (despite normal postmortem swelling) can be reliably assessed using postmortem computed tomography and is indicated by narrowed temporal horns and symmetrical herniation of the cerebellar tonsils (p < 0.001). There was a significant difference (p < 0.001) between intoxication (or asphyxia) and all other causes of death; the former causes demonstrated higher deviations of the attenuation between white and gray matter (>20 Hounsfield Units), and the gray to

  3. Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography

    Institute of Scientific and Technical Information of China (English)

    Yong Huang; Yangjia Lu; Ganlong Li; Xinsheng Lai; Hong Zhang; Chunzhi Tang; Junjun Yang

    2011-01-01

    The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.

  4. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome.

    Directory of Open Access Journals (Sweden)

    Chien Hung Chang

    Full Text Available BACKGROUND: Hyperperfusion syndrome (HPS following carotid angioplasty with stenting (CAS is associated with significant morbidity and mortality. At present, there are no reliable parameters to predict HPS. The aim of this study was to clarify whether perfusion computed tomography (CT is a feasible and reliable tool in predicting HPS after CAS. METHODOLOGY/PRINCIPAL FINDINGS: We performed a retrospective case-control study of 54 patients (11 HPS patients and 43 non-HPS with unilateral severe stenosis of the carotid artery who underwent CAS. We compared the prevalence of vascular risk factors and perfusion CT parameters including regional cerebral blood volume (rCBV, regional cerebral blood flow (rCBF, and time to peak (TTP within seven days prior to CAS. Demographic information, risk factors for atherosclerosis, and perfusion CT parameters were evaluated by multivariable logistic regression analysis. The rCBV index was calculated as [(ipsilateral rCBV - contralateral rCBV/contralateral rCBV], and indices of rCBF and TTP were similarly calculated. We found that eleven patients had HPS, including five with intracranial hemorrhages (ICHs of whom three died. After a comparison with non-HPS control subjects, independent predictors of HPS included the severity of ipsilateral carotid artery stenosis, 3-hour mean systolic blood pressure (3 h SBP after CAS, pre-stenting rCBV index >0.15 and TTP index >0.22. CONCLUSIONS/SIGNIFICANCE: The combination of severe ipsilateral carotid stenosis, 3 h SBP after CAS, rCBV index and TTP index provides a potential screening tool for predicting HPS in patients with unilateral carotid stenosis receiving CAS. In addition, adequate management of post-stenting blood pressure is the most important treatable factor in preventing HPS in these high risk patients.

  5. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi [Iwate Medical Univ., Morioka (Japan). School of Medicine

    2002-04-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23{+-}10 cm/sec in 21 FDE cases, 14{+-}3 cm/sec in 3 FDL-1 cases, 29{+-}23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58{+-}25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  6. Objective Quantification of the Regional Distribution of Radioactivity in Cerebral Emission Computed Tomography

    Science.gov (United States)

    Harris, Gordon Jonathan

    It is essential in the analysis of emission computed tomography (ECT) scans of the living human brain to be able to reliably and objectively obtain regional quantitative data. Therefore, the following thesis describes new methods for the analysis of the regional distribution of radioactivity in brain ECT images, which reduces the variability inherent in observer guided region of interest placement. The analysis methods developed include the definition of a cortical ring for producing a "cortical circumferential profile" of the cortical distribution of radioactivity. This method treats the cortex as a continuous annulus on the outer brain rim. The outer boundary of the brain can be defined either manually, or using a matched, registered magnetic resonance image (MRI), which can also be used for analysis of discrete subcortical regions, a difficult task using ECT images alone. The methods developed here were then applied to the analysis of alterations in the regional cerebral perfusion patterns which are seen in neuro-psychiatric illness. Alzheimer's Dementia, Obsessive-Compulsive Disorder and HIV Dementia were all found to have perfusion abnormalities compared to matched control groups.

  7. Regional cerebral blood flow analysis of vascular dementia by the single photon emission computed tomography

    International Nuclear Information System (INIS)

    In order to evaluate the relationship between the regional cerebral blood flow (CBF) and cerebrovascular dementia, eleven patients with vascular dementia and eight patients with non-demented infarction were studied and regional CBF were measured quantitatively with single photon emission computed tomography (SPECT) by using N-isopropyl-p-(I-123) iodoamphetamine. All cases were basal infarction and vascular dementia were diagnosed by less than 21.5 of the Hasegawa's dementia score and more than 7 of Hachinsk's ischemic score. The results of the present study were as follows: (1) Cerebrovascular dementia showed lower mean CBF value compared with non-demented group. (2) Regional CBF of bilateral frontal areas and affected basal ganglia were significantly reduced than occipital area in the dementia group. (3) A comparison of regional CBF and the Hasegawa's dementia score revealed a statistically significant correlation at the bilateral frontal areas in the dementia group. It is possible that measuring the regional CBF quantitatively by IMP-SPECT is useful for clinical analysis of vascular dementia. (author)

  8. SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY STUDY OF REGIONAL CEREBRAL BLOOD FLOW IN PATIENTS WITH HEMISPATIAL NEGLECT

    Institute of Scientific and Technical Information of China (English)

    尹雅芙; 任艳; 李亚明

    2003-01-01

    Objective.To explore the correlations between the occurrence and severity of neglect and the region,range or extent of the decrease in regional cerebral blood flow(rCBF). Methods. Nineteen dextromanual patients who were diagnosed as unilateral stroke clinically and hemispatial neglect by a neglect test battery received single photon emission computed tomography(SPECT) scans. Results. On images,the damages of patients with neglect were seen most frequently in the frontal cortex,and then in turn in the parietal cortex,occipital cortex,temporal cortex,basal ganglia and thalamus. Most patients with neglect had two or more regions damaged. The most significant region was temporal-parietal-occipi-tal(TPO)junction. The correlation coefficient between rCBF and the severity of neglect was -0.34(t=-1.5,P>0.05),and that between the decrease percentage of rCBF and the severity of neglect was 0.34(t=1.47,P>0.05). The correlation coefficients between the range,number of foci,the flow deficit size and the severity of neglect were 0.71(t=4.13,P<0.01),0.70(t=4.07,P<0.01)and 0.64(t=3.40, P<0.01),respectively. Conclusions. The severity of neglect correlates with rCBF and the decrease percentage of rCBF insignificantly,but correlates positively with the range,number of foci and the flow deficit size significantly. Hemispatial neglect is caused by the damage of multiple sites and combined damage results in more severe neglect.

  9. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  11. Effect of isovolemic, isothermic hemodialysis on cerebral perfusion and vascular stiffness using contrast computed tomography and pulse wave velocity.

    Directory of Open Access Journals (Sweden)

    Ansgar Reising

    Full Text Available BACKGROUND: Patients undergoing hemodialysis treatment have a six-fold increased risk for stroke relative to the general population. However, the effect of hemodialysis on cerebral blood flow is poorly studied and confounding factors like blood pressure and ultrafiltration as well as temperature changes have rarely been accounted for. The aim of our study was to use state-of-the-art technology to evaluate the effect of a single dialysis session on cerebral perfusion as well as on vascular stiffness. METHODS: Chronic hemodialysis patients (7 male/3 female, mean age 58 years were recruited. Cerebral blood flow and arterial pulse wave velocity were measured before and immediately after a hemodialysis session. To exclude effects of volume changes we kept ultrafiltration to a minimum, allowing no change in body weight. Isothermic conditions were maintained by using the GENIUS single-pass batch-dialysis system with a high-flux polysulfone dialyser. Cerebral blood flow was measured by contrast-enhanced computed tomography. Pulse wave velocity was measured using the SphygmoCor (AtCor Medical, USA device by a single operator. RESULTS: This study shows for the first time that isovolemic, isothermic hemodialysis neither affected blood pressure or heart rate, nor total or regional cerebral perfusion. There was also no change in pulse wave velocity. CONCLUSIONS: Mechanisms other than the dialysis procedure itself might be causative for the high incidence of ischemic strokes in this patient population. Moreover, the sole removal of uremic toxins does not lead to short-term effects on vascular stiffness, underlying the importance of volume control in this patient population.

  12. Cerebral complications of irradiation and Methotrexate application in lymphatic leukemias as revealed by computer tomography

    International Nuclear Information System (INIS)

    Eighteen children were examined whose skull had previously been irradiated. The total focal dose ranged between 15 to 30 Gy. Methotrexate was administered intraspinally, in most cases 7.5 mg twice weekly. The total dose ranged between 60 to 158.5 mg MTX. The patients were examined using computed tomography 8 to 46 months from the onset of disease. The most frequent symptoms of the effects of irradiation were cortisubcortical atrophy, then various manifestations of leukoencephalopathy which, if treatment is not discontinued leads to necrotic changes in the white matter of the hemispheres

  13. Single photon emission computed tomography (SPECT): Clinical routine diagnosis of cerebral malfunction

    International Nuclear Information System (INIS)

    Positron emission tomography is the gold standard for in vivo research in neurophysiology and pathology. The introduction of SPECT and the development of such tracers as 99mTc-HMPAYO (99mTc-d,l-hexamethylpropylenaminoxim) and, more recently, 123I-iomazenil and 123I-IBZM (123I-3-iodo-6-methoxybenzamide) allowed closer examination of the perfusion of the brain and neuroreceptor density mapping in more than the few institutions that can afford PET and the production of special tracers marked with a positron emitting nucleus. Nuclear medicine's future will be based on neuroreceptor density mapping, as further tracers will become commercially available and no other technique can probably show such low concentrations of the receptors. Probably MR techniques will be used for brain's perfusion measurement in future. For examination of a limited cerebral region xenon-enhanced CT is an alternative to perfusion measurements with HMPAO, or a very interesting supplement. Of the old techniques in nuclear medicine, examination of the liquor dynamics is still feasible and well supplemented by SPECT. (orig./MG)

  14. Accuracy of computed tomography perfusion in detecting delayed cerebral ischemia following aneurysmal subarachnoid hemorrhage: A meta-analysis

    Directory of Open Access Journals (Sweden)

    Haogeng Sun

    2013-01-01

    Full Text Available Background and Purpose: In recent years, significant literature shows that computed tomography perfusion (CTP can provide sufficient information on cerebral hemodynamics and effectively indicate delayed cerebral ischemia (DCI before the development of infarction. We aimed at performing a meta-analysis to provide a more full and accurate evaluation of CTP and CTP parameters in detecting DCI in patients with aneurysmal subarachnoid hemorrhage. Materials and Methods: We searched the PubMed, MedLine, Embase and Cochrane databases for analysis published from February 2005 to February 2013. We extracted CTP parameters, including cerebral blood volume (CBV, cerebral blood flow (CBF, mean transit time (MTT, time to peak (TTP, interhemispheric ratios for CBV and CBF and interhemispheric differences for MTT and TTP. Pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR, negative likelihood ratio (NLR, diagnostic odds ratio (DOR and the summary receiver-operating characteristic curve were determined. Results: Four research studies are met the inclusion criteria for the analysis. The pooled sensitivity, specificity, PLR, NLR and DOR of CTP for detecting the DCI were 82%, 82%, 4.56, 0.22 and 20.96, respectively. Through the evaluation of absolute CTP parameters, CBF and MTT showed diagnostic value for DCI, but CBF and TTP did not. Moreover, CBF ratio, MTT difference and TTP difference showed more diagnostic value than CBV ratio in DCI detection by the assessment of relative CTP parameters. Conclusions: As a non-invasive and short time consuming screening method, CTP own a high diagnostic value for the detection of DCI after aneurysm rupture.

  15. Simple partial status epilepticus localized by single-photon emission computed tomography subtraction in chronic cerebral paragonimiasis.

    Science.gov (United States)

    Joo, Eun Yeon; Kim, Jee Hyun; Tae, Woo Suk; Han, Sun Jung; Kim, Seunghwan; Kim, Myoung-Hee; Byun, Hong Sik; Hong, Seung Bong

    2004-10-01

    A patient with chronic cerebral paragonimiasis began to have new motor seizures of the right face manifested by clonic contractions that occurred several hundred times a day, consistent with simple partial status epilepticus. Ictal electroencephalogram discharges started from the left frontal region and then spread to the left hemisphere with left frontal maximum. But clinical seizures were limited to the right face. The frequent partial seizures were controlled by the intravenous infusion of phenytoin. Brain magnetic resonance imaging showed multiple conglomerated round nodules with encephalomalacia in the left temporal and occipital lobes. Applying the technique of ictal-interictal single-photo emission computed tomography subtraction, the authors were able to localize the focal ictal-hyperperfusion on left precentral cortex adjacent to the lesions that correspond to the anatomical distribution of left face motor area.

  16. Abnormalities in rCBF [regional cerebral blood flow] and computed tomography in patients with Alzheimer's disease and in controls

    International Nuclear Information System (INIS)

    The pattern of abnormal distribution of single photon emission computed tomography (SPECT) cerebral blood flow tracer 99m-technetium-hexamethylpropyleneamine oxime (99Tcm-HMPAO) was investigated in 14 patients with clinically diagnosed Alzheimer's disease (AD) who subsequently had post-mortem confirmation, and also in 14 elderly control subjects. These abnormalities were compared with computed tomography (CT) scans to investigate the degree to which the focal SPECT deficits were due to atrophy. Results show that SPECT imaging with 99Tcm-HMPAO and CT scanning both have a higher incidence of abnormality in AD patients than in controls and that the difference between patients and controls is greater with SPECT than with CT. Frontal SPECT and CT abnormalities in moderate/severe Alzheimer's disease occur as frequently as temporal/occipital abnormalities but the latter are rare in control subjects. Around 50% of SPECT deficits occur in CT normal brain regions, showing that atrophy is not the sole cause of SPECT deficits. (author)

  17. Comparison of Two Algorithms for Analysis of Perfusion Computed Tomography Data for Evaluation of Cerebral Microcirculation in Chronic Subdural Hematoma.

    Science.gov (United States)

    Trofimov, Alexey O; Kalentiev, George; Voennov, Oleg; Yuriev, Michail; Agarkova, Darya; Trofimova, Svetlana; Bragin, Denis E

    2016-01-01

    The aim of this work was comparison of two algorithms of perfusion computed tomography (PCT) data analysis for evaluation of cerebral microcirculation in the perifocal zone of chronic subdural hematoma (CSDH). Twenty patients with CSDH after polytrauma were included in the study. The same PCT data were assessed quantitatively in cortical brain region beneath the CSDH (zone 1), and in the corresponding contralateral brain hemisphere (zone 2) without and with the use of perfusion calculation mode excluding vascular pixel 'Remote Vessels' (RV); 1st and 2nd analysis method, respectively. Comparison with normal values for perfusion indices in the zone 1 in the 1st analysis method showed a significant (p < 0.01) increase in CBV and CBF, and no significant increase in MTT and TTP. Use of the RV mode (2nd analysis method) showed no statistically reliable change of perfusion parameters in the microcirculatory blood flow of the 2nd zone. Maintenance of microcirculatory blood flow perfusion reflects the preservation of cerebral blood flow autoregulation in patients with CSDH. PMID:27526170

  18. Cerebral damage following ventricular shunt for infantile hydrocephalus evaluated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, A.; Pasquini, U.; Menichelli, F.; Salvolini, U.

    1981-02-01

    The results of a late CT control of infantile hydrocephalus is reported with an analysis of effects of the catheter on the cerebral tissue in the immediate and late postoperative course. The most frequent finding is blood in the ventricle and/or subependymal or intraparenchymal along the catheter or near its tip.

  19. Sensitivity of 3D Gradient Recalled Echo Susceptibility-Weighted Imaging Technique Compared to Computed Tomography Angiography for Detection of Middle Cerebral Artery Thrombus in Acute Stroke

    OpenAIRE

    Amit Agarwal; Kanupriya Vijay; Krishnamoorthy Thamburaj; Sangam Kanekar; Paul Kalapos

    2014-01-01

    We aimed at comparing the sensitivity of magnetic resonance (MR) susceptibility-weighted imaging (SWI) with computed tomography angiography (CTA) in the detection of middle cerebral artery (MCA) thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI) and CTA...

  20. Evaluation of post-mortem lateral cerebral ventricle changes using sequential scans during post-mortem computed tomography.

    Science.gov (United States)

    Hasegawa, Iwao; Shimizu, Akinobu; Saito, Atsushi; Suzuki, Hideto; Vogel, Hermann; Püschel, Klaus; Heinemann, Axel

    2016-09-01

    In the present study, we evaluated post-mortem lateral cerebral ventricle (LCV) changes using computed tomography (CT). Subsequent periodical CT scans termed "sequential scans" were obtained for three cadavers. The first scan was performed immediately after the body was transferred from the emergency room to the institute of legal medicine. Sequential scans were obtained and evaluated for 24 h at maximum. The time of death had been determined in the emergency room. The sequential scans enabled us to observe periodical post-mortem changes in CT images. The series of continuous LCV images obtained up to 24 h (two cases)/16 h (1 case) after death was evaluated. The average Hounsfield units (HU) within the LCVs progressively increased, and LCV volume progressively decreased over time. The HU in the cerebrospinal fluid (CSF) increased at an individual rate proportional to the post-mortem interval (PMI). Thus, an early longitudinal radiodensity change in the CSF could be potential indicator of post-mortem interval (PMI). Sequential imaging scans reveal post-mortem changes in the CSF space which may reflect post-mortem brain alterations. Further studies are needed to evaluate the proposed CSF change markers in correlation with other validated PMI indicators. PMID:27048214

  1. A method for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Celsis, P; Goldman, T; Henriksen, L;

    1981-01-01

    of four 1 min pictures and using a fixed value for the brain:blood partition coefficient, lambda. The method is essentially based on the bolus distribution principle, and it allows the estimation of blood flow in ischemic areas. Application to positron emission tomography is discussed....

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  3. The role of additional computed tomography in the decision-making process on the secondary prevention in patients after systemic cerebral thrombolysis

    Directory of Open Access Journals (Sweden)

    Sobolewski P

    2015-12-01

    Full Text Available Piotr Sobolewski,1 Grzegorz Kozera,2 Wiktor Szczuchniak,1 Walenty M Nyka2 1Department of Neurology and Stroke, Unit of Holy Spirit Specialist Hospital in Sandomierz, Sandomierz, Poland; 2Department of Neurology, Medical University of Gdańsk, Gdańsk, Poland Introduction: Patients with ischemic stroke undergoing intravenous (iv-thrombolysis are routinely controlled with computed tomography on the second day to assess stroke evolution and hemorrhagic transformation (HT. However, the benefits of an additional computed tomography (aCT performed over the next days after iv-thrombolysis have not been determined.Methods: We retrospectively screened 287 Caucasian patients with ischemic stroke who were consecutively treated with iv-thrombolysis from 2008 to 2012. The results of computed tomography performed on the second (control computed tomography and seventh (aCT day after iv-thrombolysis were compared in 274 patients (95.5%; 13 subjects (4.5%, who died before the seventh day from admission were excluded from the analysis.Results: aCTs revealed a higher incidence of HT than control computed tomographies (14.2% vs 6.6%; P=0.003. Patients with HT in aCT showed higher median of National Institutes of Health Stroke Scale score on admission than those without HT (13.0 vs 10.0; P=0.01 and higher presence of ischemic changes >1/3 middle cerebral artery territory (66.7% vs 35.2%; P<0.01. Correlations between presence of HT in aCT and National Institutes of Health Stroke Scale score on admission (rpbi 0.15; P<0.01, and the ischemic changes >1/3 middle cerebral artery (phi=0.03 existed, and the presence of HT in aCT was associated with 3-month mortality (phi=0.03.Conclusion: aCT after iv-thrombolysis enables higher detection of HT, which is related to higher 3-month mortality. Thus, patients with severe middle cerebral artery infarction may benefit from aCT in the decision-making process on the secondary prophylaxis. Keywords: ischemic stroke, iv

  4. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Marlies, E-mail: marlies.wagner@kgu.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com [Siemens AG, Health Care Sector (Germany); Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Singer, Oliver C., E-mail: o.singer@em.uni-frankfurt.de [Hospital of Goethe University, Department of Neurology (Germany); Berkefeld, Joachim, E-mail: berkefeld@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany)

    2013-08-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.

  5. Cranial computed tomography in paediatrics

    International Nuclear Information System (INIS)

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect probable therapeutic consequences and expected diagnostic yield. In view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy. (Author)

  6. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  7. Epileptic patterns of local cerebral metabolism and perfusion in man determined by emission computed tomography of 18FDG and 13NH3

    International Nuclear Information System (INIS)

    Seventeen patients with partial epilepsy had EEG monitoring concurrent with cerebral emission computed tomography (ECT) after 18F-fluorodeoxyglucose (18FDG) and 13N-ammonia were given intravenously as indicators of local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. In 12 of 15 patients who had unilateral or focal electrical abnormalities, interictal 18FDG scan patterns clearly showed localized regions of decreased (20% to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization. These hypometabolic zones appeared normal on x-ray computed tomography in all but three patients and were unchanged on scans repeated on different days. In 5 of 6 patients who underwent temporal lobectomy, the interictal 18FDG scan correctly detected the pathologically confirmed lesion as a hypometabolic zone, and removal of the lesion site resulted in marked clinical improvement. In contrast, the ictal 18FDG scan patterns clearly showed foci of increased (82% to 130%) LCMR/sub glc/, which correlated temporally and anatomically with ictal EEG spike foci and were within the zones of interictal hypometabolism (3 studies in 2 patients). 13NH3 distributions paralleled 18FDG increases and decreases in abnormal zones, but 13NH3 differences were of lesser magnitude. When the relationship of 13NH3 uptake to local blood flow found in dog brain was applied as a correction to the patients' 13NH3 scan data, local alterations in perfusion and glucose utilization were usually matched, both in the interictal and ictal states

  8. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Tsuzura, Shigenobu [Metropolitan Medical Center of the Severely Handicapped, Fuchu, Tokyo (Japan); Matsuda, Hiroshi

    1995-07-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]-iodoamphetamine ({sup 123}I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author).

  9. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    International Nuclear Information System (INIS)

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author)

  10. Absolute quantification of cerebral blood flow in neurologically normal volunteers: dynamic-susceptibility contrast MRI-perfusion compared with computed tomography (CT)-perfusion.

    Science.gov (United States)

    Ziegelitz, Doerthe; Starck, Göran; Mikkelsen, Irene K; Tullberg, Mats; Edsbagge, Mikael; Wikkelsö, Carsten; Forssell-Aronson, Eva; Holtås, Stig; Knutsson, Linda

    2009-07-01

    To improve the reproducibility of arterial input function (AIF) registration and absolute cerebral blood flow (CBF) quantification in dynamic-susceptibility MRI-perfusion (MRP) at 1.5T, we rescaled the AIF by use of a venous output function (VOF). We compared CBF estimates of 20 healthy, elderly volunteers, obtained by computed tomography (CT)-perfusion (CTP) and MRP on two consecutive days. MRP, calculated without the AIF correction, did not result in any significant correlation with CTP. The rescaled MRP showed fair to moderate correlation with CTP for the central gray matter (GM) and the whole brain. Our results indicate that the method used for correction of partial volume effects (PVEs) improves MRP experiments by reducing AIF-introduced variance at 1.5T. PMID:19253361

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Videos related to Computed Tomography (CT) - Head About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Images related to Computed Tomography (CT) - Sinuses About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  15. Epileptic patterns of local cerebral metabolism and perfusion in man determined by emission computed tomography of /sup 18/FDG and /sup 13/NH/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.; Engel, J. Jr.; Phelps, M.E.; Selin, C.

    1979-01-01

    Seventeen patients with partial epilepsy had EEG monitoring concurrent with cerebral emission computed tomography (ECT) after /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-ammonia were given intravenously as indicators of local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. In 12 of 15 patients who had unilateral or focal electrical abnormalities, interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20% to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization. These hypometabolic zones appeared normal on x-ray computed tomography in all but three patients and were unchanged on scans repeated on different days. In 5 of 6 patients who underwent temporal lobectomy, the interictal /sup 18/FDG scan correctly detected the pathologically confirmed lesion as a hypometabolic zone, and removal of the lesion site resulted in marked clinical improvement. In contrast, the ictal /sup 18/FDG scan patterns clearly showed foci of increased (82% to 130%) LCMR/sub glc/, which correlated temporally and anatomically with ictal EEG spike foci and were within the zones of interictal hypometabolism (3 studies in 2 patients). /sup 13/NH/sub 3/ distributions paralleled /sup 18/FDG increases and decreases in abnormal zones, but /sup 13/NH/sub 3/ differences were of lesser magnitude. When the relationship of /sup 13/NH/sub 3/ uptake to local blood flow found in dog brain was applied as a correction to the patients' /sup 13/NH/sub 3/ scan data, local alterations in perfusion and glucose utilization were usually matched, both in the interictal and ictal states.

  16. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-123I IMP single photon emission computed tomography

    International Nuclear Information System (INIS)

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (Vd) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP (123I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the 123I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, pd was also significantly decreased in the pons (pd for the pons and age at onset (r=0.59, pd in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, pd obtained by 123I-IMP SPECT for patients with MJD identified by gene analysis. Our study shows that SPECT measurement of rCBF and Vd is useful for understanding the pathophysiology of MJD. (author)

  17. Comparison of cerebral blood flow data obtained by computed tomography (CT) perfusion with that obtained by xenon CT using 320-row CT.

    Science.gov (United States)

    Takahashi, Satoshi; Tanizaki, Yoshio; Kimura, Hiroaki; Akaji, Kazunori; Kano, Tadashige; Suzuki, Kentaro; Takayama, Youhei; Kanzawa, Takao; Shidoh, Satoka; Nakazawa, Masaki; Yoshida, Kazunari; Mihara, Ban

    2015-03-01

    Cerebral blood flow (CBF) data obtained by computed tomography perfusion (CTP) imaging have been shown to be qualitative data rather than quantitative, in contrast with data obtained by other imaging methods, such as xenon CT (XeCT) imaging. Thus, interpatient comparisons of CBF values themselves obtained by CTP may be inaccurate. In this study, we have compared CBF ratios as well as CBF values obtained from CTP-CBF data to those obtained from XeCT-CBF data for the same patients to determine CTP-CBF parameters that can be used for interpatient comparisons. The data used in the present study were obtained as volume data using 320-row CT. The volume data were applied to an automated region of interest-determining software (3DSRT, version 3.5.2 ) and converted to 59 slices of 2 mm interval standardized images. In the present study, we reviewed 10 patients with occlusive cerebrovascular diseases (CVDs) undergoing both CTP and XeCT in the same period. Our study shows that ratios of CBF measurements, such as hemodynamic stress distribution (perforator-to-cortical flow ratio of middle cerebral artery [MCA] region) or the left/right ratio for the region of the MCA, calculated using CTP data have been shown to correlate well with the same ratios calculated using XeCT data. These results suggest that such CBF ratios could be useful for generating interpatient comparisons of CTP-CBF data obtained by 320-row CT among patients with occlusive CVD.

  18. Neutron Computed Tomography

    International Nuclear Information System (INIS)

    Computed tomography is a non-destructive testing method which can visualize cross-section of materials based on their nuclear characteristics. In the previous work, X-ray was used as its radiation media. The aim of this experiment was to improve the computed tomography technique using neutron beam. For reconstructing the cross-section image of materials, a filtered back projection was used. Result indicated that a minimum hole shown was 3 mm in diameter using a black and white presentation. While using eight colour levels, a hole of 2 mm in diameter could be seen clearly. It is expected that neutron computed tomography can improve the results of non-destructive testing. (author). 5 refs., 6 figs

  19. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S;

    1983-01-01

    Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used...

  20. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret;

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  3. Human cerebral circulation. Positron emission tomography studies

    International Nuclear Information System (INIS)

    We reviewed the literature on human cerebral circulation and oxygen metabolism, as measured by positron emission tomography (PET), with respect to normal values and of regulation of cerebral circulation. A multicenter study in Japan showed that between-center variations in cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) values were not considerably larger than the corresponding within-center variations. Overall mean±SD values in cerebral cortical regions of normal human subjects were as follows: CBF=44.4±6.5 ml/100 ml/min; CBV=3.8±0.7 ml/100 ml; OEF=0.44±0.06; CMRO2=3.3±0.5 ml/100 ml/min (11 PET centers, 70 subjects). Intrinsic regulation of cerebral circulation involves several factors. Autoregulation maintains CBF in response to changes in cerebral perfusion pressure; chemical factors such as PaCO2 affect cerebral vascular tone and alter CBF; changes in neural activity cause changes in cerebral energy metabolism and CBF; neurogenic control of CBF occurs by sympathetic innervation. Regional differences in vascular response to changes in PaCO2 have been reported, indicating regional differences in cerebral vascular tone. Relations between CBF and CBV during changes in PaCO2 and during changes in neural activity were in good agreement with Poiseuille's law. The mechanisms of vascular response to neural activation and deactivation were independent on those of responses to PaCO2 changes. CBV in a brain region is the sum of three components: arterial, capillary and venous blood volumes. It has been reported that the arterial blood volume fraction is approximately 30% in humans and that changes in human CBV during changes in PaCO2 are caused by changes in arterial blood volume without changes in venous blood volume. These findings should be considered in future studies of the pathophysiology of cerebrovascular diseases. (author) 136 refs

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. A study of cerebral hemodynamics in various cerebrovascular disorders by means of rCBF measurement with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Using single photon emission computed tomography (SPECT) with Xe-133 inhalation method, regional cerebral blood flow (rCBF) was measured for the purpose of analyzing the pathophysiology of various cerebrovascular disorders. Included in this series were 38 normal volunteers (N), 72 patients with ischemic cerebrovascular disease (ICD), 16 with subarachnoid hemorrhage (SAH), 9 with arteriovenous malformation (AVM), 6 with Moyamoya disease (MD), and 4 with hypertensive intracerebral hematoma (HIH). In the N group, rCBF was independent of sex and laterality. Increased rCBF was observed in the frontal region, as compared with other regions. A significantly increased rCBF was observed in the thirties decade of life; the difference in rCBF was, however, not statistically significant above the age of 30 years. In the ICD group, rCBF decreased in association with severer disorder. In cases of severe disorder, a significantly decreased rCBF was observed in the whole area, as compared with the control group. SPECT allowed early detection of decreased rCBF due to vaso-spasm in the SAH group. The groups of AVM, MD, and HIH showed decreased rCBF in the surrounding areas of the lesions. (Namekawa, K.)

  6. Positron Emission Tomography—Computer Tomography Scan Used as a Monitoring Tool Following Cellular Therapy in Cerebral Palsy and Mental Retardation—A Case Report

    Directory of Open Access Journals (Sweden)

    Alok Sharma

    2013-01-01

    Full Text Available Cerebral palsy (CP is one of the non-progressive neurological diseases caused by damage to the brain tissue at birth, which leads to physical, cognitive and perceptive symptoms. Even after lifelong medical and therapeutic management there are residual deficits which affect the quality of life of the patients and their families. We examined a maximally rehabilitated, 20 year old male suffering from CP and Mental Retardation (MR. He had diplegic gait and Intelligence Quotient (IQ score of 44 with affected fine motor activities, balance, speech and higher functions. Positron Emission Tomography—Computer Tomography (PET-CT scan identified frontal, temporal, parietal, occipital, left cerebellar lobes, amygdala, hippocampus, and parahippocampus as the affected areas. He was treated with cellular therapy of Autologous Bone Marrow Derived Mono-Nuclear Cells (MNCs transplantation followed by multidisciplinary rehabilitation. Six months following therapy, PET-CT scan showed significant increase in metabolic activity in all four lobes, mesial temporal structures and left cerebellar hemisphere, also supported by clinical improvement in IQ, social behavior, speech, balance and daily functioning. These findings provide preliminary evidence to support the efficacy of cellular therapy for the treatment of CP with MR. PET-CT scan can also be viewed as an impressive tool to monitor the effects of cellular therapy.

  7. Cuantificación del signo de la arteria cerebral media hiperdensa con TCMD Quantification of hyperdense middle cerebral artery sign by multidetector computed tomography (MDCT.

    Directory of Open Access Journals (Sweden)

    Francisco Meli

    2011-12-01

    Full Text Available Objetivos. Obtener una cuantificación absoluta y relativa de la densidad en el signo de la arteria cerebral media (ACM con el fin de lograr un valor objetivo para el diagnóstico temprano de isquemia cerebral aguda con TCMD. Materiales y Métodos. Se incluyeron 40 pacientes, 20 con sospecha de isquemia cerebral aguda (edad media 73,4 años y 20 pacientes controles (edad media 71,2 años, p=0,63, que se realizaron TC cerebral con un equipo de 64 filas de detectores. La cuantificación absoluta se realizó midiendo la densidad en UH en el segmento de la ACM visualmente de mayor densidad. También se midió la densidad en el mismo segmento de la ACM contralateral para calcular la diferencia entre ambas arterias (cuantificación relativa. Resultados. En pacientes casos, la densidad media de la ACM afectada (62,5 UH, IC 99%: 46,2-78,7 fue mayor que la de la ACM contralateral (39,3 UH, IC 99%: 33,3-45,3 (p=0,0004 y también fue mayor en comparación con la ACM en pacientes controles (44,7 UH, IC 99%: 37,4-52 (p=0,0045. En la cuantificación relativa, la diferencia media entre la densidad de la ACM afectada y la de ACM contralateral en los pacientes casos fue de 23,2 UH (IC 95%: 11,7-34,7, mientras que, en pacientes controles, la diferencia media entre la densidad de la ACM derecha y la ACM izquierda fue 5,2 UH (IC 95%: 2,4-8,4 (diferencia: 17,8 UH, p=0,0032, IC 95%: 6,8-28,8. Conclusión. Mostramos diferencias significativas (absolutas y relativas en la densidad de la ACM en pacientes con sospecha de isquemia cerebral aguda en comparación con sujetos normales.Purposes. To obtain absolute and relative quantification values of density in the middle cerebral artery (MCA sign, in order to obtain an objective value for an early diagnosis of acute ischemic stroke using MDCT. Material and Methods. Forty adult patients, 20 with suspected diagnosis of acute ischemic stroke (mean age: 73.4 years and 20 controls (mean age: 71.2 years, p=0.63, underwent brain

  8. Tumour blood flow and partition coefficients: correlation with grade of cerebral gliomas using xenon-enhanced computed tomography

    International Nuclear Information System (INIS)

    It is possible to underestimate the grade of nonenhancing cerebral tumours on conventional contrast-enhanced MRI or CT. Differentiation of high- and low-grade gliomas by measurement of the brain-blood partition coefficient lambda (Tλ) with Xe-enhanced CT (XeCT) has been reported. We assessed the practical applications of XeCT in suspected low-grade astrocytomas. We examined 15 patients with tumours which showed no contrast enhancement on conventional MRI and CT, using XeCT. Tumour blood flow (TBF) and Tλ were calculated. Fourteen patients underwent surgery, one patient had a biopsy. We recognised three histological groups. While Tλ differed significantly between them, TBF did not. Group 1 contained grade II-III astrocytomas and Tλ was 0.77; group 2 contained grade I-II astrocytomas with Tλ 1.14, and group 3 four oligodendrogliomas in which a Tλ of 1.50 was found. (orig.). With 4 figs., 2 tabs

  9. Evaluation by computed tomography in premature and newborn infants

    International Nuclear Information System (INIS)

    By means of cranio-cerebral computed tomography hypoxic brain damage of varying degrees and different types may be demonstrated in premature infants and high-risk newborns. Paraventricular leucomalacia of varying extent up to porencephalic defects are found, as well as cortical infarctions, hemorrhage into brain tissue or ventricles, cerebral atrophy, developing hydrocephalus and congenital anomalies. (orig.)

  10. Differences in cerebral perfusion deficits in mild traumatic brain injury and depression using single photon emission computed tomography

    Directory of Open Access Journals (Sweden)

    Kristoffer eRomero

    2014-08-01

    Full Text Available Background: Numerous studies have shown decreased perfusion in the prefrontal cortex following mild traumatic brain injury (mTBI. However, similar hypoperfusion can also be observed in depression. Given the high prevalence of depressive symptoms following mTBI, it is unclear to what extent depression influences hypoperfusion in TBI.Methods: Mild TBI patients without depressive symptoms (mTBI-noD, n = 39, TBI patients with depressive symptoms (mTBI-D, n = 13, and 15 patients with major depressive disorder, but no TBI (MDD were given 99-m T-ECD SPECT scans within 2 weeks of injury. All subjects completed tests of information processing speed, complex attention, and executive functioning, and a self-report questionnaire measuring symptoms of psychological distress. Between group comparisons of quantified SPECT perfusion were undertaken, using univariate and multivariate (partial least squares analyses.Results: mTBI-D and mTBI-noD groups did not differ in terms of cerebral perfusion. However, patients with MDD showed hypoperfusion in several frontal (orbitofrontal, middle frontal, and superior frontal cortex, superior temporal, and posterior cingulate regions. The mTBI-D group showed poorer performance on a measure of complex attention and working memory, compared to both the mTBI-noD and MDD groups.Conclusions: These results suggest that depressive symptoms do not affect SPECT perfusion in the sub-acute phase following a mild TBI. Conversely, MDD is associated with hypoperfusion primarily in frontal regions.

  11. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  12. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  13. Dynamic computed tomography of the brain

    International Nuclear Information System (INIS)

    Dynamic computed tomography (CT) studies of the brain are based on a rapid intravenous bolus injection of radiographic contrast material immediately followed by serial CT scans. The recycling times for this technique are 1 sec or less. Dynamic studies, which are relatively non-invasive, add considerable information to the static cerebral scan as it is presently performed. The resulting time-density patterns are described and typical examples of each are shown. (orig.)

  14. Computed tomography device

    International Nuclear Information System (INIS)

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  15. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  16. Sensitivity of 3D gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography angiography for detection of middle cerebral artery thrombus in acute stroke

    Directory of Open Access Journals (Sweden)

    Amit Agarwal

    2014-11-01

    Full Text Available We aimed at comparing the sensitivity of magnetic resonance (MR susceptibility-weighted imaging (SWI with computed tomography angiography (CTA in the detection of middle cerebral artery (MCA thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI and CTA. Twenty random subjects with completely normal MRI (including SWI exam were selected as control. Two neuroradiologists (blinded to the presence or absence of stroke reviewed the SW images and then compared the findings with CT angiogram (in patients with stroke. The number of MCA segments showing thrombus in each patient was tabulated to estimate the thrombus burden. Thrombus was detected on SWI in one or more MCA segments in 30 out of 35 patients, on the first review. Of the 30, SWI showed thrombus in more than one MCA segments in 7 patients. CTA depicted branch occlusion in 31 cases. Thrombus was seen on both SWI and CTA in 28 patients. Thrombus was noted in two patients on SWI only, with no corresponding abnormality seen on CTA. Two patients with acute MCA showed no vascular occlusion or thrombus on either CTA or SWI. Only two case of false-positive thrombus was reported in normal control subjects. Susceptibility-weighted images had sensitivity and specificity of 86% and 90% respectively, with positive predictive value 94%. Sensitivity was 86% for SWI, compared with 89% for CTA, and this difference was statistically insignificant (P>0.05. Of all the positive cases on CTA (31 corresponding thrombus was seen on SWI in 90% of subjects (28 of 31. Susceptibility-weighted imaging has high sensitivity for detection of thrombus in acute MCA stroke. Moreover, SWI is a powerful technique for estimation of thrombus burden, which can be challenging on CTA.

  17. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  18. Multislice computed tomography coronary angiography

    OpenAIRE

    Cademartiri, Filippo

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England, and independently by South Mrican born physicist Allan Cormack of Tufts University, Massachusetts.1 • 2 Hounsfield was later awarded the Nobel Peace Prize and honoured with K...

  19. Pediatric cranial computed tomography

    International Nuclear Information System (INIS)

    The introduction of CT in the investigation of intercranial pathology has revolutionized the approach to clinical neurological and neurosurgical practice. This book applies the advances of cranial CT to the pediatric patient. The test is divided into two sections. The first portion describes the practical methodology, anatomy and normal and abnormal CT scan appearance, including high or low density lesions, cystic lesions and ventricular or subarachnoid space dilation. The characteristic scans for various neurological diseases are presented and discussed. The author has given special attention to the CT diagnosis of congenital malformations and cerebral neoplasms. Partial Contents: Normal Computed Tomographic Anatomy/ High Density Lesions/Low Density Lesions/Cystic Lesions; Supratentorial/Cystic Lesions; Infratentorial/Increased Head Circumference/Increased Ventricular Size/Small Ventricular Size/Cranial Lesions/Spinal Lesions/CT Cisternography/Part II CT in Neonates/Congenital Craniocerebral Malformations/Hydrocephalus/Craniosynostosis/Head Trauma/Cerebrovascular Lesions/Intracranial Lesions/Seizure Disorders/Intracranial and Other Chronic Neurological Disorders

  20. Spinal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sartor, K.

    1980-10-01

    Computed tomography (CT) of the spine and spinal cord is gaining more and more importance as a valuable investigative method in neuroradiology. Performed as a noninvasive procedure, with or without intravenous contrast enhancement, it can be used to diagnose paravertebral soft tissue lesions, constrictive lesions of the bony spinal canal, structure changes of the vertebral column or of individual vertebrae, vascular intraspinal lesions, and intraspinal tumors with abnormally high or abnormally low attenuation values. Performed as an invasive procedure, after intrathecal introduction of metrizamide, spinal CT can in selected cases be used in conjunction with conventional metrizamide myelography as an additional procedure (secondary CT-myelography) or even as initial procedure ( primary CT-myelography), taking advantage of its unique properties, namely to provide a transverse axial image of the spine and related soft tissue structures and to detect even small differences in density. Further improvement of spinal CT, particularly the routine non-invasive demonstration of the intraspinal soft tissues, is to be expected.

  1. Computed tomography apparatus

    International Nuclear Information System (INIS)

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  2. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  3. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  4. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  5. What is Computed Tomography?

    Science.gov (United States)

    ... word "tomography" is from the Greek word "tomos" meaning "slice" or "section" and "graphe" meaning "drawing." A CT imaging system produces cross-sectional ... The patient may receive an injection of a "contrast material" to facilitate visualization of vascular structure. Detectors ...

  6. The distribution of cerebral muscarinic acetylcholine receptors in vivo in patients with dementia. A controlled study with 123IQNB and single photon emission computed tomography

    International Nuclear Information System (INIS)

    A high-affinity muscarinic receptor antagonist, 123IQNB (3-quinuclidinyl-4-iodobenzilate labeled with iodine 123), was used with single photon emission computed tomography to image muscarinic acetylcholine receptors in 14 patients with dementia and in 11 healthy controls. High-resolution single photon emission computed tomographic scanning was performed 21 hours after the intravenous administration of approximately 5 mCi of IQNB. In normal subjects, the images of retained ligand showed a consistent regional pattern that correlated with postmortem studies of the relative distribution of muscarinic receptors in the normal human brain, having high radioactivity counts in the basal ganglia, occipital cortex, and insular cortex, low counts in the thalamus, and virtually no counts in the cerebellum. Eight of 12 patients with a clinical diagnosis of Alzheimer's disease had obvious focal cortical defects in either frontal or posterior temporal cortex. Both patients with a clinical diagnosis of Pick's disease had obvious frontal and anterior temporal defects. A region of interest statistical analysis of relative regional activity revealed a significant reduction bilaterally in the posterior temporal cortex of the patients with Alzheimer's disease compared with controls. This study demonstrates the practicability of acetylcholine receptor imaging with 123IQNB and single photon emission computed tomography. The data suggest that focal abnormalities in muscarinic binding in vivo may characterize some patients with Alzheimer's disease and Pick's disease, but further studies are needed to address questions about partial volume artifacts and receptor quantification

  7. Measurement of regional cerebral metabolic rate for glucose in the human subject with (F-18)-2-deoxy-2-fluoro-d-glucose and emission computed tomography: validation of the method

    International Nuclear Information System (INIS)

    Tracer techniques and models of in vitro quantitative autoradiography and tissue counting for the measure of regional metabolic rates (rMR) are combined with emission computed tomography (ECT). This approach, Physiologic Tomography (PT), provides atraumatic and analytical measurements of rMR. PT is exemplified with the regional measurement of the cerebral metabolic rate for glucose (CMRGlu) in man with (18F)-2-deoxy-2-fluoro-D-glucose (FDG) and positron ECT. Our model incorporates a k4* mediated hydrolysis of FDG-6-PO4 to FDG which then competes with phosphorylation (k3*) of FDG back to FDG-6-PO4 and reverse transport (k2*) back to blood. Although small, k4* is found to be significant. The ECAT positron tomograph was used to measure the rate constants (k1*→k4*), lumped constant (LC), stability, and reproducibility of the model in man. Since these parameters have not been measured for FDG in any species, comparisons are made to values for DG in rat and monkey. Compartmental concentrations of FDG and FDG-6-PO4 were determined and show that cerebral FDG-6-PO4 steadily accumulates for about 100 mins, plateaus and then slowly decreases due to hydrolysis. Cerebral blood FDG concentration was determined to be a minor contribution to tissue activity after 10 min. Regional CMRGlu measurements are reproducible to +- 5.5% over 5 hrs. PT allows the in vivo study ofregional biochemistry and physiology in normal and pathophysiologic states in man with a unique and fundamental capability

  8. Cerebral blood flow in acute and chronic ischemic stroke using xenon-133 inhalation tomography

    DEFF Research Database (Denmark)

    Vorstrup, S; Paulson, O B; Lassen, N A

    1986-01-01

    Serial measurements of cerebral blood flow (CBF) were performed in 12 patients with acute symptoms of ischemic cerebrovascular disease. CBF was measured by xenon-133 inhalation and single photon emission computer tomography. Six patients had severe strokes and large infarcts on the CT scan. They...

  9. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  12. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl- sup 123 I-p-iodoamphetamine with single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wakisaka, M.; Nagamachi, S.; Inoue, K.; Morotomi, Y.; Nunoi, K.; Fujishima, M. (Higashi Hospital, (Japan))

    1990-10-01

    Regional cerebral blood flow was measured using N-isopropyl-{sup 123}I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis.

  13. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl-123I-p-iodoamphetamine with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Regional cerebral blood flow was measured using N-isopropyl-123I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis

  14. Computer tomography in acute pyelonephritis

    Energy Technology Data Exchange (ETDEWEB)

    Triller, J.; Scheidegger, J.; Terrier, F.

    1983-07-01

    Computer tomography of the kidneys was performed on 30 patients with acute renal infections (acute suppurative pyelonephritis, acute renal abscess, infected cyst, pyelonephrosis, calculus perforation, retroperitoneal abscess). Computer tomography provided more accurate information concerning the extent of the renal and extra-renal inflammatory process than did the urogram or sonogram. This may significantly affect the choice of treatment, particularly concerning the use of drugs or of surgery. Angiography and retrograde pyelography may be used in selected cases, especially where there is a suspicion of acute bacterial nephritis, renal vein thrombosis or ureteric obstruction.

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ray beam follows a spiral path. A special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a ... by computer software, the result is a very detailed multidimensional ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... look like? The CT scanner is typically a large, box-like machine with a hole, or short ... spiral path. A special computer program processes this large volume of data to create two-dimensional cross- ...

  3. Evaluation of multislice computed tomographic perfusion imaging and computed tomographic angiography on traumatic cerebral infarction

    Institute of Scientific and Technical Information of China (English)

    XU Fang-hong; CHEN Wei-jian; YANG Yun-jun; DUAN Yu-xia; FU Feng-li

    2008-01-01

    Objective: To evaluate the application value of multislice computed tomographic perfusion imaging (MSCTPI) and multislice computed tomographic angiography (MSCTA) on traumatic cerebral infarction. Methods: MSCTA was performed on 10 patients who were initiailly diagnosed as traumatic cerebral infarction by normal conventional computed tomography (NCCT), among whom, 3 patients were examined by MSCTPI simultaneously. Reconstructed images of the intracranial artery were made with techniques of maximum intensity projection (MIP) and volume rendering (VR) from MSCTA scanning data. Then the graph of function of four parameters, regional cerebral blood flow (Rcbf), regional cerebral blood volume (Rcbv), mean transit time (MTT), and time to peak (TTP), acquired by the perfusing analysis software was obtained. Results: Among the 10 patients with traumatic cerebral infarction, 6 showed complex type on NCCT, which depicted abnormality on MSCTA, and 4 showed simple type on NCCT, which had negative results on MSCTA. Among the 4 patients with abnormal great vessels, 2 suffered from steno sis or occlusion of the middle cerebral artery, 1 from spasm of the anterior cerebral artery, and 1 from spasm of the vertebral-basal artery. The image of MSCTPI of 1 patient with massive cerebral infarction on the right cerebral hemisphere confirmed by CT was smaller than those of the other patients, which showed occlusion of the ipsilateral middle cerebral artery on MSCTA. Among the 6 patients whose MSCTA showed no abnormality, 4 showed simple infarction and 2 showed complex infarction. The infarction focus of 5 patients occurred in the basal ganglia and 1 in the splenium of corpus callosum. Among the 2 cases of small cerebral infarction volume on NCCT, one was normal, the other showed hypoperfusion on MSCTPI and was normal on MSCTA. Conclusion: The combination of MSCTPI and MSCTA is very useful for evaluating the change of intracranial artery in ischemic regions and assessing the cerebral

  4. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  5. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    The positron computed tomography facility has got scintillator detector rings simultaneously recording more than one tomogrphic image of different cross-sections of the patient. The detectors in neighboring rings are staggered and can be rotated with respect to each other in order to increase the count rate without loss of efficiency. (DG)

  6. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable.

  7. Studies of computed tomography as a contribution to differential diagnosis between dementia due to cerebrovascular disease (multi-infract type) and due to primarily degenerative cerebral atrophy (Alzheimers type)

    International Nuclear Information System (INIS)

    Studies of computed tomography were performed in 367 patients diagnosed as dementia clinically. The mean age was 70.1 years. By the clinicians 240 were classified as senile dementia of Alzheimer's type, 79 as multiinfarct dementia, and 48 were not determined definitely. In 3%, the CT studies did detect treatable causes like tumors, subdural hematomas and communicating hydrocephalus. In about 57% was found by CT a diffuse brain atrophy without focal tissue changes as to expect if occurring a cerebrovascular disease. In 25% there were focal changes of the brain tissue in CT to define as residuals of infarctions in addition to the signs of cerebral atrophy. The results of the CT studies were normal in 15% despite of the evidence of dementia clinically. The analysis of the material did show that a cerebrovascular disease as a cause of dementia is suspected clinically in much more cases than CT studies are able to prove focal pathological changes of the brain tissue due to disorders of cerebral blood flow really. (orig.)

  8. Studies of computed tomography as a contribution to differential diagnosis between dementia due to cerebrovascular disease (multi-infract type) and due to primarily degenerative cerebral atrophy (Alzheimers type)

    Energy Technology Data Exchange (ETDEWEB)

    Kohlmeyer, K.

    Studies of computed tomography were performed in 367 patients diagnosed as dementia clinically. The mean age was 70.1 years. By the clinicians 240 were classified as senile dementia of Alzheimer's type, 79 as multiinfarct dementia, and 48 were not determined definitely. In 3%, the CT studies did detect treatable causes like tumors, subdural hematomas and communicating hydrocephalus. In about 57% was found by CT a diffuse brain atrophy without focal tissue changes as to expect if occurring a cerebrovascular disease. In 25% there were focal changes of the brain tissue in CT to define as residuals of infarctions in addition to the signs of cerebral atrophy. The results of the CT studies were normal in 15% despite the evidence of dementia clinically. The analysis of the material did show that a cerebrovascular disease as a cause of dementia is suspected clinically in much more cases than CT studies are able to prove focal pathological changes of the brain tissue due to disorders of cerebral blood flow.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... gantry. The computer workstation that processes the imaging information is located ... in detector technology allow nearly all CT scanners to obtain multiple ...

  11. Computed tomography of gynecologic diseases

    International Nuclear Information System (INIS)

    Although computed tomography (CT) provides superb images of all areas of the body, sonography, because of its lack of ionizing radiation and its real-time and multiplanar capacities, has become the preferred initial method of evaluating the female pelvis. This has resulted in a relative paucity of information in the literature concerning CT features of benign pelvic disorders in particular and prompted the authors to review our experience with third-generation CT scanning of the uterus and ovaries

  12. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-133. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission...

  13. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  14. APPLICATION OF SINGLE PHOTON EMMISSION COMPUTED TOMOGRAPHY TO CLINICAL STUDY ON THE THERAPEUTIC EFFECT OF ACUPUNCTURE IN TREATMENT OF CHILD CEREBRAL PARALYSIS

    Institute of Scientific and Technical Information of China (English)

    于海波; 鞠琰莉; 贾少微

    2001-01-01

    Subjective: To identify the practicability and clinical values of acupuncture in the treatment of child cerebral paralysis, try to provide visualized evidence and mechanisms for acupuncture treatment of this disease. Methods: 13 cerebral palsy children including 9 cases of spasmodic type, 2 cases of ataxia type and 2 cases of mixed type, 9 males and 4 females were subjected into this study. Acupoints used were Hegu (LI 4), Quchi (LI 11 ), Zusanli (ST 36) and Sanyinjiao (SP 6) that were punctured and stimulated electrically with parameters of frequency 2/15 Hz, electric current 5 mA, and duration of stimulation 30 min. Under monitoring of Siemens ECAM/ICON SPECT System, blood flow volumes of different brain regions were observed before, during and after elctroacupuncture (EA) stimulation of the above-mentioned acupoints. Results: SPECT revealed that in these 13 infantile patients, 18 regions of the brain in-cluding 12 in the frontal lobe and 6 in the temporal lobe presented insufficiency of blood perfusion and hypofunction; during EA, these cerebral regions and parietal lobe, visual cortex, thalamus, basal ganglion and cerebellum showed improvement in blood perfusion and function in different degrees. Results of the quantitative analysis on blood flow function changing rate (BFCR)% showed a significant increase in 83.3 % of the focal regions during EA. Conclusion: Acupuncture therapy can effectively improve cerebral blood perfusion of the focus and is of clinical value in treatment of infantile cerebral paralysis.

  15. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... Tools & Resources Stroke More Single Photon Emission Computed Tomography (SPECT) Updated:Sep 11,2015 What is a ... Heart Attack Myocardial Perfusion Imaging (MPI) Positron Emission Tomography (PET) Radionuclide Ventriculography, Radionuclide Angiography, MUGA Scan Heart ...

  16. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  17. The history of computed tomography

    International Nuclear Information System (INIS)

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ)

  18. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.;

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...... contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial...

  19. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    For positron computed tomography two or more rings of scintillation detectors are used by which three or more sections of the object may be determined at a time. The rings are placed in parallel planes having got some distance from each other, axially movable collimator rings being provided for. Each collimator can be moved towards the opposite collimator and towards a central collimator which also is ring-shaped and is placed between the rows of detectors. The external and internal collimator are used for data selection and image-forming. (DG)

  20. Study on cerebral microcirculation by Optical Doppler Tomography

    Institute of Scientific and Technical Information of China (English)

    MENG Jie; DING ZhiHua; YANG Yong; GUO ZhouYi

    2008-01-01

    Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale.Rats with cranial window are used as a model,and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system,under electrical stimulation and drug administration.The results show significant differences in the blood flow velocity between experimental groups and control groups,demonstrating the feasibility of ODT in the cerebral microcircula-tion study.Compared with the conventional Doppler ultrasound,ODT provides much higher spatial resolution,and thus holds a promising future in the application of the cerebral microcirculation study,especially in the observation of the blood flow velocity in micrometer scale vessels.

  1. Study on cerebral microcirculation by Optical Doppler Tomography

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale. Rats with cranial window are used as a model, and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system, under electrical stimulation and drug administration. The results show significant differences in the blood flow velocity between experimental groups and control groups, demonstrating the feasibility of ODT in the cerebral microcircula- tion study. Compared with the conventional Doppler ultrasound, ODT provides much higher spatial resolution, and thus holds a promising future in the application of the cerebral microcirculation study, especially in the observation of the blood flow velocity in micrometer scale vessels.

  2. Cranial computed tomography in psychiatry. Kraniale Computertomographie in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Falkai, P. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany)); Bogerts, B. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany))

    1993-08-13

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.)

  3. Positron Emission Tomography—Computer Tomography Scan Used as a Monitoring Tool Following Cellular Therapy in Cerebral Palsy and Mental Retardation—A Case Report

    OpenAIRE

    Sharma, Alok; Sane, Hemangi; Paranjape, Amruta; Gokulchandran, Nandini; Kulkarni, Pooja; Nagrajan, Anjana; Badhe, Prerna

    2013-01-01

    Cerebral palsy (CP) is one of the non-progressive neurological diseases caused by damage to the brain tissue at birth, which leads to physical, cognitive and perceptive symptoms. Even after lifelong medical and therapeutic management there are residual deficits which affect the quality of life of the patients and their families. We examined a maximally rehabilitated, 20 year old male suffering from CP and Mental Retardation (MR). He had diplegic gait and Intelligence Quotient (IQ) score of 44...

  4. Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography in patients with major cerebral artery steno-occlusive diseases

    International Nuclear Information System (INIS)

    Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography (SPECT) were prospectively investigated in 100 patients with major cerebral artery, atherosclerotic, and steno-occlusive diseases. All patients underwent two SPECT studies (with and without acetazolamide challenge) at an interval of 2 or 3 days, received a questionnaire immediately after each SPECT study, and returned the answered questionnaire within 7 days after the study. None of the 100 patients studied experienced any symptoms during the SPECT study without acetazolamide challenge. Sixty-three patients (63%) developed symptoms during the SPECT study with acetazolamide challenge, such as headache, nausea, dizziness, tinnitus, numbness of the extremities, motor weakness of the extremities, and general malaise 1-3 hours (mean 1.6 hours) after administration of acetazolamide, and these symptoms lasted for 0.5-72 hours (mean 7.9 hours). Multivariate statistical analysis revealed that younger age (95% confidence interval [CI] 0.896-0.980, p=0.0047) and female sex (95% CI 1.178-16.129, p=0.0274) were significantly associated with development of symptoms with acetazolamide challenge. The incidences of the development of symptoms with acetazolamide challenge were 91% (21/23) and 41% (12/29) in subgroups of women <70 years and men ≥70 years, respectively. Patients should be informed of such adverse effects of intravenous acetazolamide administration prior to the acetazolamide challenge test for evaluation of cerebrovascular reactivity. (author)

  5. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  6. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can...

  7. Development of radioiodinated receptor ligands for cerebral single photon emission tomography

    International Nuclear Information System (INIS)

    In the last decade the use of radiolabeled ligands for the imaging of cerebral receptors by emission computed tomography (ECT) has seen rapid growth. The opportunity to routinely perform cerebral single photon emission tomography (SPET) with iodine-123-labeled ligands depends on the availability of receptor ligands into which iodine can be introduced without decreasing the required high target receptor specificity. The use of iodine-123-labeled receptor-specific ligands also depends on the availability of high purity iodine-123 at reasonable costs and the necessary imaging instrumentation. In this paper, the development and current stage of evaluation of various iodine-123-labeled ligands for SPET imaging of dopaminergic, serotonergic and muscarinic acetylcholinergic receptor classes are discussed

  8. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and comp

  9. Computed tomography of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    The cranial computed tomography (CT) is a new radiological technique with which, for the first time, minimal differences an attenuation by intracranial soft tissue can be measured exactly. The basic physical principles of computed tomography have been extensively presented by Hounsfield (1973). It is well established that the attenuation of extravasated blood measures between 35 and 45 Hounsfield units. Therefore no difficulty should be encountered in the recognition and diagnosis of extra-axial hematoma and cerebral contusion since the density of the brain parenchyma never measures more than 25 units. As the constant increase in high velocity accidents and violence, the problem of acute head injury is one of the matters of great importance in today's medical practice. Therefore it is very important to figure out the method that would allow us to diagnose easily and precisely the effects of trauma upon the brain in order to institute the proper treatment at the earliest possible moment. Computed tomography allows us to make a diagnosis quickly and in a non-invasive manner. The CT scan was carried out on 310 head trauma cases in the department of radiology, St. Mary's and Kang Nam St. Mary's Hospital, Catholic Medical College, for 16 months from June 1979 to October 1980. All the scans were obtained with the Hitachi CT-H2 scanner and the scans were repeated following intravenous injection of high dose of contrast media (roughly 1.8 cc per kg body weight of 60% Conray). We have reviewed the CT scans of 310 patients got acute head injury in order to assess the location of brain lesions, the relationship between the CT densities of hematomas and their stage, the shape and mass effect of the extra-axial hematomas, and the effect of contrast enhancement. The results were as follows: 1. Of all 310 cases of the head injuries, epidural hematoma was 13.5%, subdural hematoma was 8.7%, subdural hygroma was 10%, cerebral contusion was 39%, hydrocephalus and atrophy was 3.9% and

  10. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  11. COMPUTED TOMOGRAPHY PERITONEAL CANCER INDEX

    Directory of Open Access Journals (Sweden)

    Tiutiuca RC

    2006-07-01

    Full Text Available Peritoneal surface malignancy results from seeding of gastrointestinal cancer or abdomino-pelvic sarcoma, or it can occur as a primary disease, such as peritoneal mesothelioma. In the past, this clinical situation was treated only with palliative intent. Actual treatment options for surgical management uses cytoreductive surgery which combines peritonectomy and visceral resection in an effort to remove all visible cancer within the abdomen and pelvis. Then the peritoneal cavity is flooded with chemotherapy solution. To select patients for this agressive approach quantitative prognostic indicators for carcinomatosis must be evaluated. The peritoneal cancer index (PCI is a synthesis of the distribution of tumor and a lesion size score. In such conditions abdominal medium contrast computed-tomography it is very helpful in identification of neoplasic implants.

  12. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  13. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  14. Diagnostic usefulness of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Tsugawa, R.; Yamakawa, Y. (Kanazawa Medical Univ., Uchinada, Ishikawa (Japan))

    1981-07-01

    Computed tomography (CT) has been used as a diagnostic technique in various urological diseases. Here demonstrated is a case of ureteral incontinence with double renal pelvis whose upper one has ectopic ureteral orifice. Also a case of ureteral stricture in transplanted kidney and three cases of uric acid calculi are demonstrated. CT provides accurate information in each diagnostic procedure. The use of CT in the diagnosis of urinary stones is estimated. CT number of 75 stones with single component shows specific distribution in relation to the component; ex. calcium stones: 900 - 1000, cystine: 700 - 800, struvite: 600 - 700, uric acid: 400 - 500. Structure and component of the stone is easily demonstrated by CT, especially about nonopaque calculi, whose image is positively displayed only by CT.

  15. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  16. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  17. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...

  18. 重型颅脑外伤灌注CT结果与脑灌注压的相关性%Correlation of brain perfusion computed tomography results and cerebral perfusion pressure in patients with severe head trauma

    Institute of Scientific and Technical Information of China (English)

    徐裕; 冯东侠; 高恒; 那汉荣; 徐伟东; 周新民

    2012-01-01

    目的 探讨重型颅脑外伤患者灌注CF结果与脑灌注压监测结果的相关性.方法 50例重型颅脑外伤患者分为两组:T组28例,C组22例,人院时头颅CT平扫有明显异常.在行灌注CT时,同时监测平均动脉压(MAP)及颅内压(ICP),计算脑灌注压(CPP).应用直线回归分析灌注CT参数[局部脑血容量(rCBV)、局部脑血流(rCBF)和平均通过时间(MTT)]与CPP的相关性.结果 根据灌注CT结果,T组分为两个亚组:T1组,16例,灌注CT结果与CPP呈弱相关;T2组,12例,两者存在强相关.T1、T2和C组间的灌注CT参数均有明显差异.T1组的rCBF为(18.8±8.0)cm3·100g1·min-2,明显低于T2组的(60.2±21.3)cm3·100g1·min-1和C组的(48.3±11.0)CM3·100g1·min-1(P<0.01).T1、T2组灌注CT参数与相应CPP值之间均显著相关(P<0.01).结论 灌注CT结合ICP监测能提供有价值的评估脑血管自动调节功能是否完好的信息,有助于指导治疗.%Objective To investigate the correlation of brain perfusion computed tomography (CT) results and cerebral perfusion pressure (CPP) in patients with severe head trauma. Methods Perfusion CT results of 50 patients with head trauma were analyzed , who were divided into two groups of T(28 cases, severe head trauma with abnormal CT findings during admission) and C(22 cases,head trauma with normal CT findings during admission). The patients underwent perfusion CT and MAP and ICP were measured at the same time, by which CPP was calculated. The correlation between perfusion CT results [regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF) and MTT] and corresponding CPP was analyzed using linear regression analysis. Results According to perfusion CT results, group T was divided into two subgroups of Tl (16 cases, characterized by a weak correlation between the perfusion-CT results and the corresponding CPP values) and T2(12 cases,characterized by a strong correlation between the perfusion-CT results and the corresponding

  19. Measurement of regional cerebral blood flow by positron emission tomography

    International Nuclear Information System (INIS)

    The principal advantage of positron emission tomography over other methods for measuring cerebral blood flow stems from the accurate, quantitative three-dimensional measurements of regional brain radioactivity that are possible with this technique. As a result, accurate quantitative measurements of regional cerebral blood flow can be obtained for both superficial and deep cerebral structures. The value of PET for investigating central nervous system physiology and pathology extends far beyond this, however. Through the use of different radiotracers and appropriate mathematical models, PET can be applied to the measurement of a wide variety of physiologic variables. Measurements of rCBF tell only part of the story. Experience with PET and with a variety of other techniques has taught us that rCBF is at times a poor indicator of the metabolic, functional, and biochemical status of cerebral tissue. It is only by understanding the interaction of all of these factors that our understanding of neurologic disease can advance. It is in the investigation of these complex relationships that the real value of PET resides

  20. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils. PMID:18402165

  1. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  2. Computed tomography studies on patients with mucopolysaccharidoses

    International Nuclear Information System (INIS)

    The appearances on computed tomography (CT) in eight patients with mucopolysaccharidosis Type I, two with mucopolysaccharidosis Type II and two with mucopolysaccharidosis Type IIIB are presented. Reference is also made to two further cases in which the CT showed special features. Follow-up scans were obtained to assess the evolution of the changes. The place of CT in the diagnosis of complications due to thecal involvement is examined. The density of grey matter on the CT scans was similar to that of normal brain. Inhaled xenon did not produce any special enhancement which could be helpful in assessing the degree of the mucopolysaccharide deposition within cerebral cells. Symmetrical low attenuation in the white matter was a very common finding. This work has shown that the stage in the evolution of the mucopolysaccharidoses at which hydrocephalus develops as a complication is highly variable and CSF diversion procedures are sometimes indicated to improve the quality of the patients' lives. These indications are briefly discussed. We consider that CT is essential for the adequate appraisal of these patients and to identify some treatable complications. (orig./MG)

  3. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  4. Fracture of the orbit: computed tomography appearance

    International Nuclear Information System (INIS)

    The main mechanisms of orbital fractures and their clinical symptoms are exposed. The computed tomographic appearance is described and the implication of computed tomography for therapeutic indications is evaluated as a function of clinical symptoms: visual impairment, anomaly of pupillary reaction to light, ophthalmoplegia, exophthalmos and associated injuries such as intracranial hematomas. The role of computed tomography for the follow-up of these patients is considered

  5. Computed tomography of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Kyun; Lee, Sun Wha; Kim, Soon Yong [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1980-12-15

    It is generally accepted that the computed tomography is an extremely accurate means to obtain more definite information on the diagnosis of renal masses, although the conventional excretory urography remains the primary tool in the diagnosis of renal disorders. The authors studied 62 cases of proven renal disorders among 758 abdominal CT scans performed during the period from Oct. 1977 to Jan. 1980 in Kyung Hee University Hospital. The results were as follows: 1. Of 23 simple renal cyst cases, 20 cases were found incidentally and 17 of them were over 50 years of age. 2. The CT scan have proved to be an extremely accurate means in differentiating benign renal cyst from neoplastic origin; based on attenuation value, demarcation from normal renal parenchyme and thickness of wall, especially the attenuation value. 3. CT scan holds great promise in diagnosing renal tumors, especially in staging of tumor and determining surgical feasibility and its approach. 4. Pathology and its extension of retroperitoneal space was demonstrated accurately by CT and cause of nonfunctioning kidney could be often explained without retrograde pyelography. 5. Associated polycystic changes in liver, spleen and pancreas to polycystic kidney was easily diagnosed by CT alone.

  6. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  7. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  8. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring;

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  9. Computed tomography in abnormalities of the hip

    International Nuclear Information System (INIS)

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip join can be measured by means of computed tomography. (Auth.)

  10. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  11. Computational analysis of cerebral cortex

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Abe, Osamu; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine, Tokyo (Japan)

    2010-08-15

    Magnetic resonance imaging (MRI) has been used in many in vivo anatomical studies of the brain. Computational neuroanatomy is an expanding field of research, and a number of automated, unbiased, objective techniques have been developed to characterize structural changes in the brain using structural MRI without the need for time-consuming manual measurements. Voxel-based morphometry is one of the most widely used automated techniques to examine patterns of brain changes. Cortical thickness analysis is also becoming increasingly used as a tool for the study of cortical anatomy. Both techniques can be relatively easily used with freely available software packages. MRI data quality is important in order for the processed data to be accurate. In this review, we describe MRI data acquisition and preprocessing for morphometric analysis of the brain and present a brief summary of voxel-based morphometry and cortical thickness analysis. (orig.)

  12. Contrast enhancement in computed tomography

    International Nuclear Information System (INIS)

    There appears little question that cerebral contrast enhancement by iodinated material is to a great extent a reflection of a loss of integrity of the blood-brain barrier, expect in those instances where large vascular channels contain a sufficiently large pool of iodinated material of sufficient density and size to be visualized directly. (orig./VJ)

  13. FDG positron emission computed tomography in a study of aphasia

    International Nuclear Information System (INIS)

    Positron emission computed tomography (PECT) using 18F-2-fluoro-2-deoxy-D-glucose (FDG) was used to investigate the correlations between clinical status, anatomy (as described by CT), and metabolism in five patients with stable aphasia resulting from ischemic cerebral infarction. Local cerebral metabolic activity was diminished in an area larger than the area of infarction demonstrated by CT. In one patient, FDG PECT revealed a metabolic lesion that probably caused the aphasic syndrome and was not apparent by CT. The data suggest that reliance on CT in delineating the extent of the brain lesion in aphasia or other neuropsychological defects can be misleading; FDG PECT may provide important additional information. Two patients with similar metabolic lesions had very different clinical syndromes, showing that even when currently available methods are combined, major gaps remain in clinicoanatomical correlations in aphasia

  14. 抑郁症患者局部脑血流灌注变化研究%Detection of cerebral blood flow with single emission computed tomography in depressive patients

    Institute of Scientific and Technical Information of China (English)

    余俊丽; 焦举; 许杰华; 程木华; 张峰; 张勇

    2009-01-01

    目的 分析抑郁症患者单光子发射型计算机断层显像(SPECT)局部脑血流(SCBF)灌注变化的特点,并初步探讨rCBF显像在抑郁症患者中的诊断价值. 方法 对10例正常人及临床诊断为抑郁症的32例患者分别进行SPECT局部脑血流灌注显像,利用感兴趣区(ROI)法观察rCBF情况;11例患者同期行MRI普通扫描.结果 32例抑郁症患者中31例发现rCBF显像异常,共检出71个病灶,分别位于双侧额叶、颞叶、基底节、海马、扣带回及左侧岛叶,其中57个病灶位于颞叶、海马、扣带回及岛叶,即边缘系统,9个病灶位于额叶,5个病灶位于基底节;基底节区病灶局部脑血流灌注均增高,其他部位病灶均降低;双侧大脑半球rCBF病灶构成比差异无统计学意义(χ~2=409,P=0.790).11例患者同期做MRI扫描,3例发现异常(2例轻度脑萎缩,1例海马萎缩),而此11例患者rCBF显像均发现异常.1例正常人rCBF未发现异常显像.结论 大多数抑郁症患者存在脑边缘系统rCBF降低,部分患者存在基底节区rCBF增高.SPECT能敏感地发现抑郁症患者rCBF灌注的变化,对抑郁症的诊断具有一定的价值.%Objective To analyze the changes of regional cerebral blood flow (rCBF) with SPECT in depressive patients, and explore the diagnosis value of rCBF imaging for depression. Methods The rCBF imaging was detected by single emission computed tomography (SPECT) on 32 depressive patients and 10 normal subjects, and the characteristics of rCBF changes were assessed with a region-of-interest (ROI) technique. Normal MRI scans were conducted on 11 patients at the same stage. Results Abnormal rCBF was showed in 31 patients with 71 focuses that were located in the bilateral frontal lobe (9), the basal ganglia (5) and the limbic system (57), including the temporal lobe, the hippocampus, the cingulated gyms and the left insular cortex. All abnormalities presented a decreased rCBF except the basal ganglia. No

  15. Computed tomographic findings of cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Nak Kwan; Nam, Kyung Jin; Park, Churl Min; Eun, Chung Kie; Lee, Sun Wha [Kyung Hee Unversity Hospital, Seoul (Korea, Republic of)

    1983-03-15

    Paragonimiasis is widely distributed in Far East and Southeast Asia, particularly in Korea. The central nervous system is the most frequent location for paragonimiasis outside the lungs. We analyzed the computed tomographic findings of 17 cases which were diagnosed pathologically and clinically as cerebral paragonimiasis. The results were as follows: 1. The ratio of male to female was 10 : 7 and about 88% of cases were under the age of 40 years. 2. The common locations of cerebral paragonimiasis were the occipital (12 cases) and temporal (11 cases) lobes. 3. Precontrast CT findings of cerebral paragonimiasis were low density with calcifications in 6 cases, low and isodensities in 4 cases, mixed densities in 3 cases, only low density in 2 cases and only calcification in 2 cases. Hydrocephalus (7 cases), mass effect (6 cases), atrophic change (6 cases) and cyst formation (3 cases) were associated. 4. The shape of calcifications in CT scan were soap-bubble or ring in 6 cases, nodular or oval in 6 cases, stipple in 4 cases and amorphous conglomerated in 2 cases. 5. The contrast -enhanced 8 cases were 5 ring or rim like, 2 nodular and 1 irregular enhancements, while 9 cases were not enhanced.

  16. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  17. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B;

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  19. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented

  20. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study*

    OpenAIRE

    Gao, Nuo; Zhu, Shan-an; He, Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types o...

  1. Evaluation of laryngeal carcinoma by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jeong Ho; Kim, Su Mi; Lee, Sun Wha; Eun, Tchung Ki; Kim, Soon Yong [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1984-09-15

    The limitation of direct or indirect laryngoscopy and laryngogram in determining the exact site and anatomic location of laryngeal carcinoma were well documented by many authors. As compared with laryngoscopy and laryngogram, computed tomographic study for laryngeal cancer is more exact and accurate method demonstrating anatomic sites of involvement, invasion into deep soft tissue spaces of endolarynx, destruction of laryngeal cartilages and cervical metastasis. Fourteen laryngeal cancer patients proven by laryngoscopic biopsy were further examined by computed tomography for staging. The authors compared laryngoscopic findings with those of computed tomography, and their clinical, surgical and computed tomographic findings were analysed. The results were as follows; 1. All patients were proved as squamous cell carcinoma. They were 12 males and 2 females aged over 50 yr. 2. Common clinical symptoms were hoarsense, dysphagia and swallowing difficulty. The primary anatomic sites determined by CT were 8 transglottic, 2 glottic, 2 supraglottic and 1 pyriform sinus respectively. They were 2 T1, 7 T2,1 T3, 3 T4 by TNM systems, respectively. (One case was difficult to evaluate exactly). 3. Invasion into deep soft tissue spaces of endolarynx, cartilage destruction, and neck metastasis were relatively predominant in transglottic carcinomas. 4. Compute tomography was superior in evaluating tumor invasion, especially into deep sift tissue spaces of endolarynx, laryngeal cartilages and metastasis to soft tissue and lymph nodes of neck. However computed tomography had some limitation in determining primary site of laryngeal cancer.

  2. Usefulness of computed tomography in recurrent nephrolithiasis

    International Nuclear Information System (INIS)

    For five cases of recurrent stone formers we performed Computed Tomography, which revealed non-visualized small stones on KUB and uric acid stones. Case 1 was primary hyperparathyroidism. Case 2 had several episodes of spontaneous stone passage without any stone shadow on routine X-ray examination. Case 3 had single ureteral stone on X-ray film. Case 4 had several episodes of spontaneous passage of mixed stones (uric acid and calcium oxalate). Case 5 had bilateral radiolucent large renal stones. We emphasized the superiority of Computed Tomography in search and prophylactic therapy of the stone formation. (author)

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are located in ... ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  4. Computed tomography in congenital muscular dystrophy (Fukuyama type)

    International Nuclear Information System (INIS)

    Central-nervous system involvement in 26 patients with congenital muscular dystrophy (CMD) was studied using computed tomography (CT). CT was carried out using the EMI-1000 or 1010. The most characteristic finding in the CT was a low-density area in the white matter, seen in 15 out of the 26 (58%). Ventricular dilatation was also noted in 21 out of the 26 (80%), and cortical atrophy in 16 (65%). In one case, asymmetry of the lateral ventricle was observed. Half of the patients had a low-density area in the white matter in addition to cerebral atrophy, while only three (12%) showed normal CT findings. From the relation between the CT findings and IQ in patients with CMD, those with a low-density area in addition to cerebral atrophy and those with cerebral atrophy alone had extremely low IQs compared with those with a low-density area and with normal CT findings. From the relation between the CT findings and the EEG in patients with CMD, seizure discharges, such as a spike or a sharp wave complex and a spike, were most frequently seen in those with a low-density area in the white matter in addition to cerebral atrophy, and among those patients epileptic seizures occurred in three. From the relation between the CT findings and the stage of disability in patients with CMD, those with a low-density area in addition to cerebral atrophy showed severe motor disability. From the relation between CT findings and age in patients with CMD, severe CT findings were seen in the younger group. On ophthalmological examination, one of the most important findings was the evident bulateral optic nerve atrophy noted in several cases. (J.P.N.)

  5. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  8. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  9. Neutron computed tomography of rat lungs

    International Nuclear Information System (INIS)

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 μm, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  10. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    B. van Thielen; F. Siguenza; B. Hassan

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  11. Computed tomography scanning during a traumatic resuscitation

    NARCIS (Netherlands)

    L.F.M. Beenen; R. Adams; R.W. Koster; T. Otto

    2011-01-01

    In cardiopulmonary resuscitation, computed tomography (CT) imaging could be of decisive importance to therapeutic strategy making but is yet unavailable because of incompatibility of CT scanning and manual chest compressions. In this report, we describe a case in which CT scanning was performed on a

  12. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  13. Lung Nodule Detection in Screening Computed Tomography

    CERN Document Server

    Gori, I; Cerello, P; Cheran, S C; De Nunzio, G; Fantacci, M E; Kasae, P; Masala, G L; Pérez-Martínez, A; Retico, A

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

  14. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  15. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... child may have, and if there is a history of heart disease, asthma, diabetes, kidney disease or ... the patient. The computer that processes the imaging information and monitor are ... in detector technology allow new CT scanners to obtain multiple slices ...

  17. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blery, M.; Hautefeuille, P.; Jacquenod, P. and others

    1987-09-01

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses.

  18. Acute pancreatitis: diagnostic value of ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    The value of ultrasonography and computed tomography for the diagnosis, extension, pronostic, complications and etiology of acute pancreatitis is discussed. Ultrasonography and computed tomography guided interventional radiology techniques are valuable in the management of pancreatitis complications such as abscesses

  19. Cerebral blood flow single-photon emission tomography with 123I-IMP in vascular dementia

    International Nuclear Information System (INIS)

    Cerebral blood flow differences between patients with vascular dementia, patients with multiple lacunar infarction without cognitive dysfunction, and age-matched controls were examined. Thirty four patients with vascular dementia (VD) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All the patients had routine assessment including history, physical and neurological examinations, neuropsychological assessment, blood tests, EEG, head MRI, and single photon emission computed tomography (SPECT). All of them fulfilled the NINDS-AIREN diagnostic criteria for vascular dementia. Thirty nine patients with multiple lacunar infarction without cognitive dysfunction and 110 age-matched controls were included in this study. Mean cerebral blood flow (mCBF) and regional cerebral blood flow (rCBF) were measured using N-isopropyl-P-123I-iodoamphetamine (123I-IMP) and SPECT imager. The mCBF in VD was 27.6±5.3 ml/100 g/min, while those in the control group and multiple lacunar infarction without cognitive dysfunction were 36.6±6.1 ml/100 g/min and 32.5±5.5 ml/100 g/min, respectively. The patients with VD demonstrated significantly reduced mCBF and rCBF in twenty regions including both cerebellar hemispheres as compared with those of the control group. Although there was no significant rCBF differences in bilateral inferior occipital regions and the right cerebellar hemisphere between patients with VD and multiple lacunar infarction without cognitive dysfunction, we could find significant lower rCBF in the remaining brain areas. In spite of the severity of VD, the diffuse decrease of cerebral blood flow was recognized in all patients with VD. (author)

  20. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  1. Practical management of computed tomography

    International Nuclear Information System (INIS)

    For examinations of the spinal canal is used computed myelography as an adjunct to water-soluble conventional myelography. For CT alone about 3.5 g. of metrizamide in isotonic solution is adequate for all investigations. If the constrast medium has to be run into the head by gravity, as in the detection of cerebrospinal fluid fistula or empty sella, or for detailed examination of the basal cisterns, phenobarbitone 100 mg. t.d.s. is commenced on the eve of the examination and continued for 48 hours. A similar dose is also administered to epileptic subject. If fits should occur they are treated with intravenous diazepam and prophylactic phenobarbitone is administered. (orig./AJ)

  2. Computed tomographic findings of cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Weon Tae; Jung, Min Ki; Kang, Heoung Keun; Chung, Hyon De [Chonnam University Medicine School, Gwangju (Korea, Republic of)

    1988-10-15

    Authors analyzed the computed tomographic (CT) findings of 19 cases pathologically and clinically proven cerebral paragonimiasis that were performed at Chonnam University Hospital from April 1983 through March 1987. The results were as follows: 1. Male to female ratio was 15:4 and the most prevalent age group was 3rd decade (7 cases). The common symptoms were epileptic seizure (16 cases) and headache (12 cases). 2. The multiplicity of cerebral paragonimiasis was 7 of 19 cases and the distributions of lesion were occipital (11 cases), temporal (6 cases), frontal (5 cases) and parietal (5 cases) lobe. 3. The calcification on CT scan were single (7 cases) or multiple (7 cases) and the shape of calcification were nodular (10 cases), soap babble of ring (8 cases), and stippled (6 cases). The pattern of contrast enhancement were ring (5 cases) or nodular (1 case), and along the basal cistern (1 case with arachnoiditis). 4. 12 out of 13 cases, had long clinical symptoms over 3 years with calcifications, could be analyzed according to Valentine's vascular territory; 6 cases in PCA territory, 3 in MCA and 3 in ACA. 5. CT findings were noted according to the duration of symptoms; 5 cases, had symptoms less than 1 year, showed abscess (5 cases) and arachnoiditis (1 case) with brain edema, mass effect, hydrocephalus and contrast enhancement but no calcification in all. One case, had symptom of 1 year and 2 months, showed partially calcified granulomatous lesion with perifocal edema and contrast enhancement, 13 cases, had symptoms over 3 years, showed multiple calcification with brain atrophy (10 cases), but no contrast enhancement in all cases.

  3. Inflammatory disease of the brain diagnosed by computed tomography

    International Nuclear Information System (INIS)

    Inflammatory disease of the brain, particularly of pyogenic etiology, may be most accurately assessed by the use of computed tomography and contrast enhancement. Examples of cerebritis, evolving and mature intracerebral abcesses, and inflammatory extracerebral collections are presented and discussed, particularly with reference to differential diagnosis and the problem of infectious versus neoplastic etiology. Ancillary studies, particulary selective arteriography, are reviewed where appropriate. The residual changes of inflammatory disease of the brain after medical and/or surgical therapy are illustrated, and the value of serial examinations is emphasized. The rural indigent patient population (American Indian) served by the University of New Mexico Medical Center is a source of case material providing several examples of severe and untreated intracerebral infectious processes heretofore not described in the literature. (orig.)

  4. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis. (author)

  5. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  6. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  7. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  8. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  9. Biliary obstruction: Helical computed tomography cholangiography evaluation

    International Nuclear Information System (INIS)

    Helical computed tomography cholangiography (HCTC) takes advantage of the improvement in the quality of multiplanar and three-dimensional reconstructions resulting from the volumetric acquisition of data achieved with helical computed tomography and the indirect opacification of the bile ducts provided by cholangiographic contrast media. This method was used to evaluate 31 patients with suspected biliary obstruction over a one-year period and the findings were compared with those of direct cholangiography and/or surgery. Biliary opacification was sufficient to allow three-dimensional reconstructions in 90,3% of cases. Sensitivity was 81% for the diagnosis of choledochoolithiasis and 100% for ascariasis, choledochal cysts and anatomic variants of the biliary tree. Our results indicate that HCTC is a valuable alternative as a diagnostic method prior to direct cholangiography. Direct cholangiography should be reserved for those patients who require it as part of a therapeutic procedure

  10. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  11. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  12. The diagnostic contribution of computed tomography in intranasal carcinoma with retrobulbar, oral and brain invasion in a canine: case report; Contribuicao da tomografia computadorizada no diagnostico de carcinoma intranasal com invasao retrobular, oral e cerebral em canino: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Zardo, Karen Maciel, E-mail: kmz@bol.com.br; Belotta, Alexandra Frey; Babicsak, Viviam Rocco; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria; Zanoni, Diogo Souza; Costa, Denis Carvalho [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Veterinaria

    2012-07-01

    Intranasal tumors are uncommon and in most cases are malignant, aggressive and with low to moderate potential for metastasis. Clinical signs are usually caused by progressive obstruction of the upper airways. The test cytopathological also is a diagnosis method, but the definitive diagnosis is made by histopathological. Computed tomography (CT) is recommended to treatment planning. A poodle was attended at the veterinary hospital with a clinical history of epistaxis and nasal and ocular secretions, seizures and severe dyspnoea. The animal underwent to radiographic examination of the chest and skull as well as helical computed tomography of the nasal cavity and brain before and after the administration of intravenous contrast. The CT findings revealed an expansive bilateral nasal cavity neoformation, with involvement of the retrobulbar space, right frontal sinus, brain and oral cavity, suggesting a neoplastic or an infectious process. The CT examination allowed the material collection, directly from the mass, to cytological examination, providing the diagnosis of carcinoma. CT also allowed the determination of the unfavorable prognosis of the patient and the treatment planning which not included the surgical excision of the neoformation. Although CT was not conclusive in the diagnosis of carcinoma, it was essential to accurately define the extent of the lesion, to guide the collection of material directly from the tumor and to determine the prognosis of the animal, proving to be an extremely useful tool in cases of tumors intranasal in dogs. (author)

  13. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  14. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  15. Improvement in computed tomography spatial resolution

    International Nuclear Information System (INIS)

    One of the most important recent developments in transmission computed tomography is the improvement in spatial resolution. Applications of this technical advance to the neuroradiographic exploration of such structures as spinal cord, nerve roots and pituitary gland - as well as the orbits and inner and middle ear - is still limited to a few centers. Increased spatial resolution appears to be an effective means to increase our diagnostic capabilities. The higher dosimetry connected with this modality needs to be emphasized. (orig.)

  16. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  17. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  18. Computed tomography in gastrointestinal stromal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias [Department of Diagnostic Radiology, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany); Furtwaengler, Alex [Department of Abdominal Surgery, University Hospital Freiburg, Hugstetter Strasse 55, 79106, Freiburg (Germany)

    2003-07-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (<5 cm) showed a sharp tumor margin with homogeneous density and structure on unenhanced and contrast-enhanced images, and were characterized by an intraluminal tumor growth. Intermediate sized GIST (>5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography

  19. Analysis of computed tomography of ovarian tumor

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Makoto; Taniike, Keiko; Nishiguchi, Hiroyasu

    1987-07-01

    One hundred and twenty six patients with ovarian mass were studied with computed tomography (CT) and classified into five groups according to its margin and inner structure. The incidence of malignancy of cystic ovarian mass with smooth margin was low and that of solid ovarian mass with irreglar margin was high. Three cases (6.7 %) of malignant ovarian tumor demonstrated completely cystic pattern. Ovarian teratomas contained well defined component of fat density.

  20. HORSESHOE KIDNEY: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2015-06-01

    Full Text Available Background and Objective: Horseshoe kidney is the most common renal fusion anomaly with a reported prevalence of 1 in 400 persons with a male to female ratio of 2:1. In many cases its presence may go unnoticed and undiagnosed because the patient may remain asymptomatic throughout life. The objective of our study is to report radiological and anatomical features of horseshoe kidney detected incidentally during retrospective evaluation of multidetector computed tomography scans. Materials and Methods: Contrast enhanced multidetector computed tomography scans of 682 patients, 355 males and 327 females, were reviewed retrospectively. Results: Seven cases of horseshoe kidney were detected incidentally, six males and one female, with an incidence of 1.02 %. In all cases, malrotation of the kidneys were observed with the hilum facing anteriorly or anterolaterally. The isthmus was made up of parenchymal tissue in all the cases and the fusion was midline in four cases and lateral in three cases. Horseshoe kidney in all cases was supplied by multiple renal arteries, varying from 3 to 6. In three cases symmetrical arterial supply and in the rest asymmetrical supply was observed. Nephrolithiasis and hydronephrosis were noted in two patients. No other associated congenital anomaly was observed in all seven patients. Conclusion: Contrast enhanced multidetector computed tomography evaluation of patients with horseshoe kidney provide excellent information about its vascularity, collecting system and other associated conditions.

  1. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik;

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  2. Single photon emission computed tomography-guided Cerenkov luminescence tomography

    Science.gov (United States)

    Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie

    2012-07-01

    Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.

  3. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. PMID:21147376

  4. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    International Nuclear Information System (INIS)

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma

  5. Cerebral blood flow and metabolism for Broca's aphasia using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Toshiaki

    1987-12-01

    A total of 11 patients with Broca's aphasia (BA) underwent positron emission tomography (PET) with the purpose of investigating the responsible region and the symptomatic flow and metabolism thresholds for BA. Computed tomography (CT) was concurrently performed. In the group of 3 patients undergoing PET with C-11 glucose, both PET and CT provided abnormal findings in the region that is thought to be responsible for BA (Broca's area), including the cortex and subcortex in the anterior region to Sylvian fissure. The Broca's area in the remaining one was shown as low C-11 accumulation area on PET and as isodensity on CT. The second group, consisting of 8 BA patients and 30 control patients without BA, underwent PET using O-15 steady method. PET showed reduction of regional cerebral blood flow (rCBF) and oxygen metabolic rate (rCMRO/sub 2/) in the Broca's area in all BA patients. Computed tomography showed abnormal low density in the Broca's area in 3 patients, and abnormal findings in the basal ganglionic region and subcortex without evidence for abnormal low density in the Broca's area in the other 5 patients. Comparison of rCBF and rCMRO/sub 2/ in BA patients with those in control patients may show the symptomatic thresholds to be 20 - 27 ml100 gmin for rCBF and 2.0 ml100 gmin for rCMRO/sub 2/. (Namekawa, K.).

  6. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  7. Fluorescence Computed Tomography with Polychromatic Source Data

    International Nuclear Information System (INIS)

    Fluorescence computed tomography is a synchrotron imaging technique aiming at reconstructing the fluorescence emission within a sample object. For a polychromatic source hitting the object, the amount of fluorescence detected is defined by a linear equation. For the monochromatic case, the operator is a Generalized Attenuated Radon Transform (GART). The main goal is to reconstruct the density function, given the sinogram data and the weight function. An eficient iterative algorithm for the inversion of the GART was presented recently by the authors. This inversion can only be performed if the weight function is previously known, which means that μ = μ(·, ε) and λ are also known. For monochromatic XFCT (acronym for x-rays fluorescence computed tomography), the determination of λ is a dificult task, and we have considered the approximation λ ≈ μ, which is valid for low energies ranging from 3Kev to 10Kev. So, for solving our problem, the first step is to find μ given the polychromatic sinogram. There are different approaches for this in the literature. Recently, an elegant and efficient method for solving this problem was introduced, using a fixed point algorithm. Opposite to this, where μ(·, ε) needs to be computed for all ε element of E, we claim that the integral of μ(·, ε) for all ε has a physical meaning and provides a good aproximation for the solution. Also we present fast algorithm for computations.

  8. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    This study was designed to rate the clinical value of [123I]iodoamphetamine (IMP) or [99mTc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [123I]IMP or [99mTc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  9. ROLE OF COMPUTED TOMOGRAPHY IN CERBROVASCULAR ACCID ENT

    Directory of Open Access Journals (Sweden)

    Kalra

    2013-02-01

    Full Text Available ABSTRACT: Cerebrovascular accident is characterized by the s udden loss of blood circulation to an area of the brain resulting in a corresponding lo ss of neurologic function. Stroke is mainly of two types ischaemic or haemorrhagic and differentiat ion is important as the management differs substantially with the type of stroke. Aim o f the study was to compare the clinical diagnosis with computed tomography diagnosis and to d ifferentiate between the types of stroke. The study included 90 clinically suspected patients o f stroke who underwent CT imaging at Konaseema Institute of Medical Sciences, Amalapur am, A.P. from July,2009 to September,2011.The incidence of CVA was significantl y higher in males than females (73.3% n=66 vs 26.6% n=24.The most frequently affected a ge group was 50 to 69Years of age(67%The incidence of ischaemic stroke was signi ficantly higher than haemorrhagic stroke both in males and females. The most common localizations were parietal and fron tal lobe. The middle cerebral artery followed by the anterior cerebral artery we re the commonest vascular territories affected. The sensitivity of clinical diagnosis remained 90%. But clinical diagnosis is not dependable for therapeutic & prognostic purpose when pla nning for anti-coagulation or thrombotic therapy.

  10. Single photon emission computed tomography in periatric frontal epilepsy

    International Nuclear Information System (INIS)

    Neuroradiological examinations were made in 9 pediatric patients with frontal epilepsy by using single photon emission computed tomography (SPECT), cat scanning (CT) and magnetic resonance imaging (MRI). Two patients (22%) had abnormal findings on both CT and MRI; and 6 patients (67%) had them on SPECT, two of whom had findings corresponding to focal sites on EEG. Among the 6 patients, 5 were suspected of having decreased regional cerebral blood flow (rCBF), corresponding to 84%-94% of the contralateral blood flow. Two patients were evaluable before and after seizures; one had increased rCBF at the time of frequent seizures and returned to normal after seizures; and the other had no abnormality in the early stage of epilepsy, but had decreased rCBF after seizures. SPECT appears to provide a simple, useful tool in evaluating cerebral hemodynamics in infantile epilepsy, although serial hemodynamic changes with developmental process of central nerves and the time of examination must be considered according to individual patients. (N.K.)

  11. Computed tomography in the management of cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    The radiological technique of computed tomography (CT) used in neurological diagnosis of vascular diseases of the brain is explained, and its application to specific clinical situations is described. Cerebral infarcts of varying ages can be visualized, with a recent ischemic infarct appearing as a region of decreased density. Hemorrhagic infarcts in acute and subacture stages also can be visualized, and the advantage to the patient is that the procedure is virtually without risk. CT is the procedure of choice in confirming a diagnosis of hemorrhage into the brain parenchyma or into the ventricular system. Hematomas not readily detectable by conventional angiography may be demonstrated by CT, particularly if they are large. Cerebral aneurysms and arteriovenous malformations cannot be detected by CT unless calcification or clotted blood is present. However, several radiologists have noted enhancement of the diagnostic capability for both neoplasms and vascular lesions such as aneurysms and AV malformations, when an intravenous infusion of angiographic contrast material is started prior to the scan. It is noted that considerable technical skill is required to keep CT equipment operating properly, and photographs of scans may be made a part of the patients's clinical record. An attachment to this document corrects an error on a previous technical assistance memorandum. (GRA)

  12. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  13. NOTE: Independent component analysis of dynamic contrast-enhanced computed tomography images

    Science.gov (United States)

    Koh, T. S.; Yang, X.; Bisdas, S.; Lim, C. C. T.

    2006-10-01

    Independent component analysis (ICA) was applied on dynamic contrast-enhanced computed tomography images of cerebral tumours to extract spatial component maps of the underlying vascular structures, which correspond to different haemodynamic phases as depicted by the passage of the contrast medium. The locations of arteries, veins and tumours can be separately identified on these spatial component maps. As the contrast enhancement behaviour of the cerebral tumour differs from the normal tissues, ICA yields a tumour component map that reveals the location and extent of the tumour. Tumour outlines can be generated using the tumour component maps, with relatively simple segmentation methods.

  14. Independent component analysis of dynamic contrast-enhanced computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Koh, T S [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Yang, X [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Bisdas, S [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Hospital, Theodor-Stern-Kai 7, D-60590 Frankfurt (Germany); Lim, C C T [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-10-07

    Independent component analysis (ICA) was applied on dynamic contrast-enhanced computed tomography images of cerebral tumours to extract spatial component maps of the underlying vascular structures, which correspond to different haemodynamic phases as depicted by the passage of the contrast medium. The locations of arteries, veins and tumours can be separately identified on these spatial component maps. As the contrast enhancement behaviour of the cerebral tumour differs from the normal tissues, ICA yields a tumour component map that reveals the location and extent of the tumour. Tumour outlines can be generated using the tumour component maps, with relatively simple segmentation methods. (note)

  15. White matter of the cerebellum demonstrated by computed tomography: normal anatomy and physical principles.

    Science.gov (United States)

    Maravilla, K R; Pastel, M S; Kirkpatrick, J B

    1978-04-01

    Although computed tomography (CT) delineation of normal white matter of the cerebral hemispheres has been well documented, there has been no description of white matter within the cerebellum. Through the use of phantom studies, CT number correlations between cerebellum and cerebral hemispheres, and anatomic correlation with in vitro specimens, the ability to visualize cerebellar white matter is demonstrated. Thin sections decrease volume averaging and enable consistent imaging of these structures. Size and shape of the corpus medullaris on CT scan may vary with the scan angle and level of section. Representative examples of various normal appearances are illustrated.

  16. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  17. Single photon emission computed tomography using 99Tcm-HMPAO in Alzheimer's disease

    International Nuclear Information System (INIS)

    Brain single photon emission computed tomography (SPET) using 99mTcm-hexamethylpropyleneamine oxime (HMPAO) was performed in 37 patients satisfying standard clinical criteria of Alzheimer's disease (AD), correlating results with patient's age of onset, duration of illness, severity of dementia, neuropsychological impairment, computed tomography (CT) and EEG findings. All had abnormal SPET: 23 were bilaterally symmetric, 10 bilaterally asymmetric and four showed unilateral low regional cerebral perfusion. Low perfusion in bilateral parietal regions was the most consistent finding and was present alone or with other abnormal regions in 31 patients (84%). The only significant clinical correlation was found between asymmetric SPECT changes and onset of disease before the age of 65 years. 50% of patients with presenile onset, but only 19% with senile onset had asymmetric low regional cerebral perfusion. Fifteen of the 36 patients had normal brain CT scans, and 9 of 31 patients receiving EEG examination had normal results. (author)

  18. Diffuse optical correlation tomography of cerebral blood flow during cortical spreading depression in rat brain

    Science.gov (United States)

    Zhou, Chao; Yu, Guoqiang; Furuya, Daisuke; Greenberg, Joel; Yodh, Arjun; Durduran, Turgut

    2006-02-01

    Diffuse optical correlation methods were adapted for three-dimensional (3D) tomography of cerebral blood flow (CBF) in small animal models. The image reconstruction was optimized using a noise model for diffuse correlation tomography which enabled better data selection and regularization. The tomographic approach was demonstrated with simulated data and during in-vivo cortical spreading depression (CSD) in rat brain. Three-dimensional images of CBF were obtained through intact skull in tissues(~4mm) deep below the cortex.

  19. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  20. Multidetector Computed Tomography in Acute Joint Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Haapamaeki, V.V.; Kiuru, M.J.; Mustonen, A.O.; Koskinen, S.K. [Helsinki Univ. Central Hospital (Finland). Helsinki Medical Imaging Center

    2005-10-01

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement.

  1. Computed tomography studies of human brain movements

    International Nuclear Information System (INIS)

    Rhythmic brain movements have been revealed by sets of sequential computed tomography scans of human brains (seen retrospectively to be normal). These scans have shown that both (unenhanced) brain parenchymal density and the shapes of the elements of the supratentorial ventricular/cisternal system are subject to wave motions having similar periods - ranging from 26 s through 56 s, 77-96 s, 109 s and 224 s to 224 X 2 s (or even longer), with good correlation between peak values. These motions, as well as phase variations between the waves, suggest a peristaltic movement of cerebrospinal fluid through the ventricular/cisternal system with progressive axial damping

  2. Emerging clinical applications of computed tomography

    Science.gov (United States)

    Liguori, Carlo; Frauenfelder, Giulia; Massaroni, Carlo; Saccomandi, Paola; Giurazza, Francesco; Pitocco, Francesca; Marano, Riccardo; Schena, Emiliano

    2015-01-01

    X-ray computed tomography (CT) has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications. PMID:26089707

  3. Computed tomography of cardiac pseudotumors and neoplasms.

    Science.gov (United States)

    Anavekar, Nandan S; Bonnichsen, Crystal R; Foley, Thomas A; Morris, Michael F; Martinez, Matthew W; Williamson, Eric E; Glockner, James F; Miller, Dylan V; Breen, Jerome F; Araoz, Philip A

    2010-07-01

    Important features of cardiac masses can be clearly delineated on cardiac computed tomography (CT) imaging. This modality is useful in identifying the presence of a mass, its relationship with cardiac and extracardiac structures, and the features that distinguish one type of mass from another. A multimodality approach to the evaluation of cardiac tumors is advocated, with the use of echocardiography, CT imaging and magnetic resonance imaging as appropriately indicated. In this article, various cardiac masses are described, including pseudotumors and true cardiac neoplasms, and the CT imaging findings that may be useful in distinguishing these rare entities are presented. PMID:20705174

  4. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  5. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning ...... for their measurements. The industrial items are suitable artefacts for CT measurements of this kind, and each participant has been offered to keep a set used for the measurements in the comparison.......An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...

  6. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  7. Emerging clinical applications of computed tomography

    Directory of Open Access Journals (Sweden)

    Liguori C

    2015-06-01

    Full Text Available Carlo Liguori,1 Giulia Frauenfelder,2 Carlo Massaroni,3 Paola Saccomandi,3 Francesco Giurazza,4 Francesca Pitocco,4 Riccardo Marano,5 Emiliano Schena,3 1Radiology Unit, AORN A Cardarelli, 2Radiology Unit, AOU Federico II, Naples, 3Measurement and Biomedical Instrumentation Unit, 4Radiology Unit, Università Campus Bio-Medico di Roma, 5Department of Radiological Sciences, Institute of Radiology, Catholic University of Rome, A Gemelli University Hospital, Rome, Italy Abstract: X-ray computed tomography (CT has recently been experiencing remarkable growth as a result of technological advances and new clinical applications. This paper reviews the essential physics of X-ray CT and its major components. Also reviewed are recent promising applications of CT, ie, CT-guided procedures, CT-based thermometry, photon-counting technology, hybrid PET-CT, use of ultrafast-high pitch scanners, and potential use of dual-energy CT for material differentiations. These promising solutions and a better knowledge of their potentialities should allow CT to be used in a safe and effective manner in several clinical applications. Keywords: computed tomography, X-ray, thermometry, dual-energy, ultrafast scanner, guidance, photon-counting technology

  8. Computed tomography of juvenile nasopharyngeal angiofibroma

    International Nuclear Information System (INIS)

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma

  9. Introduction to neutron stimulated emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, Carey E Jr [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Bender, Janelle E [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Sharma, Amy C [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Kapadia, Anuj [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Xia, Jessie [Department of Biomedical Engineering and Department of Radiology, Duke Advanced Imaging Laboratories Box 2623DUMC, Duke University, Durham, NC 27710 (United States); Harrawood, Brian [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Tourassi, Georgia D [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Lo, Joseph Y [Department of Radiology, Duke Advanced Imaging Laboratories Box 3202DUMC, Duke University, Durham, NC 27710 (United States); Crowell, Alexander [Department of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27710 (United States); Howell, Calvin [Department of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27710 (United States)

    2006-07-21

    Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.

  10. Statistical parametric mapping in brain single photon computed emission tomography after carbon monoxide intoxication.

    Science.gov (United States)

    Watanabe, N; Nohara, S; Matsuda, H; Sumiya, H; Noguchi, K; Shimizu, M; Tsuji, S; Kinuya, S; Shuke, N; Yokoyama, K; Seto, H

    2002-04-01

    The purpose of this retrospective study was to assess regional cerebral blood flow in patients after carbon monoxide intoxication by using brain single photon emission computed tomography and statistical parametric mapping. Eight patients with delayed neuropsychiatric sequelae and ten patients with no neuropsychiatric symptoms after carbon monoxide intoxication were studied with brain single photon emission tomography imaging with 99mTc-hexamethyl-propyleneamine oxime. Forty-four control subjects were also studied. We used the adjusted regional cerebral blood flow images in relative flow distribution (normalization of global cerebral blood flow for each subject to 50 ml x 100 g(-1) x min(-1) with proportional scaling) to compare these groups with statistical parametric mapping. Using this technique, significantly decreased regional cerebral blood flow was noted extensively in the bilateral frontal lobes as well as the bilateral insula and a part of the right temporal lobe in the patients with delayed neuropsychiatric sequelae as compared with normal volunteers (Pparametric mapping is a useful technique for highlighting differences in regional cerebral blood flow in patients following carbon monoxide intoxication as compared with normal volunteers. The selectively reduced blood flow noted in this investigation supports the contention that the decrease following carbon monoxide intoxication may be prolonged and further worsen in the frontal lobe. In addition, the present study may help to clarify the characteristics of the pathophysiological alteration underlying delayed neuropsychiatric sequelae.

  11. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  12. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-09-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients.

  13. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    International Nuclear Information System (INIS)

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients

  14. Computed tomography in suppurative meningitis. CT and clinical findings in the acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Akira; Fujiwara, Katsuhiko; Iino, Shigeru (Kyoto Prefectural Univ. of Medicine (Japan))

    1982-06-01

    Computed tomography abnormalities revealed in 18 of 29 patients (62%) with infantile supprative meningitis. The abnormalities included ventricular dilatation (12 cases), subdural edema (8), cerebral infarction (4), cerebral atrophy (3), encephalitis (2), and cerebral herniation (1). The comparative study of CT pictures and clinical findings in the acute stage of the disease showed that the high incidence of these abnormalities occurred in the following conditions: 1) The age was less than 1 year, 2) establishment of the diagnosis took more than 5 days, 3) glucose of the cerebrospinal fluid was less than 200 mg/dl, 4) protein of the cerebrospinal fluid was more than 200 mg/dl, and 5) convulsion occurred 24 hrs after institution of the treatment.

  15. Perfusion computed tomography imaging of autoimmune pancreatitis

    International Nuclear Information System (INIS)

    Perfusion computed tomography (P-CT) is now available for the analysis of pancreatic blood flow. The aim of this study was to clarify pancreatic blood perfusion in AIP patients and the changes after steroid treatment. Color map imaging of P-CT and pancreatic time CT density curve (TDC) demonstrated that the pancreatic blood flow was attenuated in AIP patients. Pancreatic volumetric blood flow FV values of 11 AIP patients (82.7/min) were significantly lower than those of 12 normal controls (163.5/min, p=0.0006). AIP patients received steroid treatment and were re-examined, of these, 9 patients showed significantly elevated FV values after treatment (76.2/min and 109.8/min, p=0.0391, respectively). However, the changes of the values after the treatment differed in varying degrees among the individuals. P-CT is a useful method for the analysis of the blood flow in pancreatic diseases. (author)

  16. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    is a well-established technique for tolerance verification of manufactured parts. Two reference objects for performance characterization of industrial CT systems were developed within the scope of the Ph.D. thesis. Namely, CT ball plate and CT tree, which were further used for identification......X-ray computed tomography (CT) is a measuring technique which has become an important technology in the production environment over the last years. Due to a number of advantages of CT compared to, e.g., coordinate measuring machines (CMMs), CT has been recently spread in the field of manufacturing...... is an important factor for decision making about manufactured parts. However, due to many influences in CT, estimation of the uncertainty is a challenge, also because standardized procedures and guidelines are not available yet. In this thesis, several methods for uncertainty estimation were applied in connection...

  17. Polychromatic phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Polychromatic phase-contrast radiography differs from traditional (absorption-only) radiography in that the method requires at least a partially coherent x-ray source and the resulting images contain information about the phase shifts of x-rays in addition to the traditional absorption information. In a typical embodiment, this effect results in a measurable enhancement in image contrast at the edges of objects. In this study, a phase-contrast imaging system was adapted to allow an object to be imaged at multiple projections, and these projections were used to generate phase-contrast computed tomography images. The images obtained with this technique show edge enhancements surrounding the objects within the image

  18. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  19. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  20. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  1. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  2. Computed tomography findings in convergent strabismus fixus

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1995-08-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author).

  3. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...... quality remain unclear. This is a problem of high practical concern, because the large scale of CT problems makes detailed exploration of the parameter space very time-consuming. Due to the limited quantitative understanding, sparse reconstruction has not yet become the method of choice in practical CT......In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...

  4. PRIMA+: a proton computed tomography apparatus

    International Nuclear Information System (INIS)

    The proton Computed Tomography (pCT) is a medical imaging method, based on the use of proton beams with kinetic energy of the order of 250 MeV, aimed to directly measure the stopping power distribution of tissues thus improving the present accuracy of treatment planning in hadron therapy. A pCT system should be capable to measure tissue electron density with an accuracy better than 1% and a spatial resolution better than 1 mm. The blurring effect due to multiple Coulomb scattering can be mitigated by single proton tracking technique. As a first step towards pCT the PRIMA+ Collaboration built a prototype capable to carry out a single radiography and a tomographic image of a rotating object. This apparatus includes a silicon microstrip tracker to identify the proton trajectory and a YAG:Ce calorimeter to measure the particle residual energy.

  5. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  6. Radiation Protection in Paediatric Computed Tomography

    International Nuclear Information System (INIS)

    The number of examinations with radiation exposure has been increasing mainly due to advances in computed tomography (CT) technology, with a rapid expansion of CT utilization. Annually, 3.6 billion diagnostic and medical and dental examinations involving radiation are performed worldwide. The contribution of CT to collective dose due to medical X rays is up to 47–59%. A 2009 report of the National Council on Radiation Protection and Measurements (NCRP) estimates that 8–10% of CT examinations in the United States of America are performed on children; the growth in CT utilization is higher in the paediatric than adult population in the USA; and there is a particularly pronounced rise in adolescents undergoing chest CT in the emergency department setting for suspected pulmonary embolism or trauma. The reasons for the growing incidence of CT are new indications for CT with the advent of multidetector CT, overcautious ordering related to medico-legal problems and probably financial incentive systems

  7. Radiation Protection of Patients in Computed Tomography

    International Nuclear Information System (INIS)

    The use of radiation for medical diagnostic examinations contributes over 95% of human-made radiation exposure and is only exceeded by natural background as a source of exposure to the world’s population. In fact, for several developed countries, the increased use of high dose X ray technology, in particular, computed tomography (CT), has resulted in a situation in which the annual collective and per capita doses of ionizing radiation due to diagnostic radiology have exceeded those from natural background radiation. In light of this marked increase in worldwide collective effective dose from medical diagnostic procedures, and with CT scans accounting for half of this, there is great emphasis on the subject of radiation protection of patients in CT

  8. Myocardial hypoperfusion on conventional contrast computed tomography.

    Science.gov (United States)

    Ching, Shing; Chung, Tak Shun

    2015-10-01

    Non–electrocardiogram (ECG)–gated contrast computed tomography (CT) is commonly performed to exclude aortic dissection in chest pain patients. Besides evaluating the aorta for dissection flap, attention should be paid to the myocardium for areas of hypoenhancement that may suggest ischemia. Current models of multidetector CT enable assessment of myocardial perfusion with minimal motion artifact even without ECG gating. Transmural hypoenhancement with preserved wall thickness in a coronary distribution is highly specific for acute myocardial infarction. We report 2 cases of acute chest pain with initial nondiagnostic studies that underwent CT aortogram to exclude dissection. Instead, the CT showed myocardial hypoenhancement in left anterior descending artery territory. Myocardial hypoenhancement occurred before ST-segment elevation on ECG, suggesting that recognition of this important finding may lead to earlier revascularization decisions. PMID:26321167

  9. Neutron stimulated emission computed tomography: Background corrections

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, Carey E. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States)]|[Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States); Sharma, Amy C. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); E-mail: anc4@duke.edu; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Harrawood, Brian P. [Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Tourassi, Georgia D. [Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States); Lo, Joseph Y. [Dept. of Biomedical Engineering, Duke University, Durham, NC 27708 (United States)]|[Duke Advanced Imaging Laboratories, Dept. of Radiology, Duke University, Durham, NC 27708 (United States)]|[Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States); Kiser, Matthew R.; Crowell, Alexander S. [Dept. of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27708 (United States); Pedroni, Ronald S. [North Carolina A and T State University, Greensboro, NC (United States); Macri, Robert A. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Tajima, Shigeyuki [Dept. of Physics, University of Virginia, Charlottesville, VA (United States); Howell, Calvin R. [Medical Physics Graduate Program, Duke University, Durham, NC 27708 (United States)]|[Dept. of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27708 (United States)

    2007-01-15

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each.

  10. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  11. Regional cerebral blood flow in acute stage with ischemic cerebrovascular disease by xenon-133 inhalation and single photon emission computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, Hiroyuki; Iino, Katsuro; Kojima, Hisashi; Saito, Hitoshi; Suzuki, Mikio; Watanabe, Kazuo; Kato, Toshiro

    1987-05-01

    Single photon emission computed tomography (SPECT) with xenon-133 inhalation method was undertaken within 48 hr after the onset in 68 patients with ischemic cerebrovascular disease. The results for regional cerebral blood flow (rCBF) were compared with concurrently available computed tomography (CT) scans. In patients with cerebral infarction, SPECT detected ischemic lesions earlier than CT, with the detectability being 92 %. The area with a decreased blood flow, as seen on SPECT, was more extensive than the low density area on CT, with a concomitant decrease in blood flow in the contralateral cerebral hemisphere. Crossed cerebellar diaschisis was associated with stenosis of the internal carotid artery in 50 % (7/14), and with stenosis of the middle cerebral artery in 35 % (9/26). Abnormal SPECT findings were seen in 47 % (8/17) of the patients with transient ischemic attack (TIA). Five TIA patients had a decreased rCBF on SPECT, which was not provided by CT scans. On the contrary, small infarct lesions in the cerebral basal ganglia, as observed in 4 patients, was not detected by SPECT, but detected by CT. This may imply the limitations of SPECT in the detection of deep-seated lesions of the cerebrum. The results led to the conclusion that SPECT can be performed safely even in acute, seriously ill patients to know changes in rCBF because it is noninvasive and is capable of being repeated in a short time. (Namekawa, K.).

  12. Intraoperative Perfusion Computed Tomography in Carotid Endarterectomy: Initial Experience in 16 Cases

    Science.gov (United States)

    Xue, Zhe; Peng, Dingwei; Sun, Zhenghui; Wu, Chen; Xu, Bainan; Wang, Fuyu; Zhou, Dingbiao; Dong, Tianxiang

    2016-01-01

    Background This study aimed to evaluate the changes in perfusion computed tomography (PCT) parameters in carotid endarterectomy (CEA), and to discuss the use of intraoperative PCT in CEA. Material/Methods Sixteen patients with carotid stenosis who also underwent CEA with intraoperative CT were recruited in this study. We calculated quantitative data on cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), and the relative parameter values, including relative CBF (rCBF), relative CBV (rCBV), and relative TTP (rTTP). The role of PCT was assessed and compared to conventional monitoring methods. Results There were no significant differences in any of the parameters in the anterior cerebral artery (ACA) territory (P>0.05). In the middle cerebral artery (MCA) territory, the CBF and CBV increased and TTP decreased in the operated side during CEA; the rCBF and rCBV increased and the rTTP decreased significantly (P<0.05). In 16 patients, CT parameters were improved, SSEP was normal, and MDU was abnormal. In 3 patients, CBF increased by more than 70% during CEA. Relative PCT parameters are sensitive indicators for detecting early cerebral hemodynamic changes during CEA. Cerebral hemodynamics changed significantly in the MCA territory during CEA. Conclusions Intraoperative PCT could be an important adjuvant monitoring method in CEA. PMID:27657307

  13. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J N; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  14. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  15. The role of computed tomography in the laryngeal injury

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hoon Sik [Capital Armed Forces General Hospital, Seongnam (Korea, Republic of)

    1984-03-15

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results.

  16. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  17. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  18. Giant hepatic cavernous hemangioma. Findings on computed helical tomography

    International Nuclear Information System (INIS)

    Objective: To describe computed helical tomography characteristics of the giant hepatic cavernous hemangioma. Method: During five years, we evaluated 21 patients with 21 giant hepatic cavernous hemangiomas with computed helical and multislice tomography. We included 18 women (86%) and 3 men (14%) with a mean age of 45 years. Results: The mean size of hemangiomas was 10.4 cm. Non enhanced computed tomography Showed 21 hemangiomas with lower density than adjacent hepatic parenchyma , all hemangiomas showed a central cleft area with low density. None hemangioma showed calcifications neither internal septa. In enhanced helical tomography all lesions demonstrated a globular, peripheral enhancing pattern with centripetal filling that begin in the arterial phase and continued in portal and delayed phases. None of the lesions showed complete filling. Conclusion: giant hepatic cavernous hemangiomas showed low attenuation in non enhanced computed tomography. central cleft area was very frequently seen. The enhancement pattern is characteristic, starting at the periphery with centripetal filling but it was never complete.

  19. Cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitario Cajuru

    International Nuclear Information System (INIS)

    Objective: to identify and analyze the prevalence of cranial computed tomography findings in patients admitted to the emergency unit of Hospital Universitario Cajuru. Materials and methods: cross-sectional study analyzing 200 consecutive non contrast-enhanced cranial computed tomography reports of patients admitted to the emergency unit of Hospital Universitario Cajuru. Results: alterations were observed in 76.5% of the patients. Among them, the following findings were most frequently observed: extracranial soft tissue swelling (22%), bone fracture (16.5%), subarachnoid hemorrhage (15%), nonspecific hypodensity (14.5%), paranasal sinuses opacification (11.5%), diffuse cerebral edema (10.5%), subdural hematoma (9.5%), cerebral contusion (8.5%), hydrocephalus (8%), retractable hypodensity /gliosis/ encephalomalacia (8%). Conclusion: the authors recognize that the most common findings in emergency departments reported in the literature are similar to the ones described in the present study. This information is important for professionals to recognize the main changes to be identified at cranial computed tomography, and for future planning and hospital screening aiming at achieving efficiency and improvement in services. (author)

  20. Cerebral blood flow imaged with ultrahigh-resolution optical coherence angiography and Doppler tomography

    OpenAIRE

    Ren, Hugang; Du, Congwu; Pan, Yingtian

    2012-01-01

    Speckle contrast based optical coherence angiography (OCA) and optical coherence Doppler tomography (ODT) have been applied to image cerebral blood flow previously. However, the contrast mechanisms of these two methods are not fully studied. Here, we present both flow phantom and in vivo animal experiments using ultrahigh-resolution OCA (μOCA) and ODT (μODT) to investigate the flow sensitivity differences between these two methods. Our results show that the high sensitivity of μOCA for visual...

  1. Comparison of mean cerebral transit time and single-photon emission tomography for estimation of stroke outcome

    Energy Technology Data Exchange (ETDEWEB)

    Lees, K.R. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom); Weir, C.J. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom)]|[Robertson Centre for Biostatistics, University of Glasgow (United Kingdom); Gillen, G.J. [Department of Nuclear Medicine, Western Infirmary, Glasgow (United Kingdom); Taylor, A.K. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Ritchie, C. [Acute Stroke Unit, University Department of Medicine and Therapeutics, Western Infirmary, Glasgow (United Kingdom)]|[Department of Occupational Therapy, West Glasgow Hospitals University NHS Trust, Glasgow (United Kingdom)

    1995-11-01

    This study aimed to compare the effectiveness of SPET and mean cerebral transit time (MCTT) in the prediction of functional outcome. Sixty-three patients undergoing cerebral computed tomography (CT), technetium-99m MCTT, and technetium-99m-labelled hexamethylpropylene amine oxime SPET soon after acute ischaemic stroke had outcome assessed after 3 months. Cerebral CT, SPET and MCTT scans were interpreted without reference to the clinical data; a single independent observer assessed outcome using the Barthel Index. The 3-month Barthel score in survivors was significantly correlated with volume of lesion on SPET and with the ratio of mean affected hemisphere transit times to mean unaffected hemisphere transit times, but not with CT lesion volume. Stepwise logistic regression identified volume of lesion on SPET as the only significant predictor of good functional outcome. The overall predictive accuracy was 73%. It is concluded that MCTT, although significantly correlated with functional outcome, failed to predict good functional recovery in individual stroke survivors. Since SPET provides more detailed localisation of perfusion deficits, and since SPET lesion volume can be used to predict functional outcome, SPET remains preferable to MCTT when perfusion imaging is required. (orig./MG)

  2. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study

    Institute of Scientific and Technical Information of China (English)

    GAO Nuo; ZHU Shan-an; HE Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach.Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%,for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.

  3. Reproducibility in the assessment of acute pancreatitis with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: eofilho@ig.com.br; eoffilho@uol.com.br

    2007-11-15

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index ({kappa}). Results: Interobserver agreement was {kappa} 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was {kappa} = 0.796 and 0.732 for unenhanced morphological index; {kappa} 0.725 and 0.802 for contrast- enhanced morphological index; {kappa} = 0.674 and 0.849 for presence of pancreatic necrosis; {kappa} = 0.606 and 0.770 for pancreatic necrosis extension; and {kappa} = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  4. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  5. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  6. Radiation Doses from Computed tomography in Iraq

    International Nuclear Information System (INIS)

    Radiation doses to Patient during CT scanner and the radiological risk are significant. Patient dose survey has been conducted to investigate the Iraq patient radiation doses received in CT scanners in order to established reference dose levels. These doses are Entrance Surface Dose (ESD),computed tomography dose index(CTDI)), and dose length product (DLP). Two CT scanner were investigated in this study were, Siemens Somatom Plus 4, located in at medical city of Baghdad, and Philips, Optimus located in privet hospital at Baghdad. ESD were measured by TLD and Dosimax ionization chamber for head, chest, and abdomen for both sex and different weights. The TLD results were higher than that measured with Dosimax due to scattered radiation .The scattering factor which is the ratio between dose measured by TLD and that measured by ionization chamber range between (1.14-1.34) compare to international measurement which is range between (1.1-1.5).The (ESD) measured by the two methods were agree well after the subtraction of scattering dose, and have compered with original research. Dose profile were measured using array of TLD chips shows that its full width at half maximum is(7.99 mm) approximately equal the slice thickness(8 mm). Our results compare with reference level at U.K, European Guidelines and

  7. Quantitative investigations of megavoltage computed tomography

    Science.gov (United States)

    Rogers, Myron; Kerr, Andrew; Salomons, Greg; Schreiner, L. John

    2005-04-01

    Megavoltage computed tomography (MVCT) has been an active area of research and development in image guided radiation therapy. We have been investigating a particular implementation of MVCT in conjunction with studies of the potential for tomotherapy with a Cobalt-60 radiation source. In this paper, we present results comparing MVCT using a Co-60 source and a 4 MV linear accelerator to conventional kVCT imaging. The Co-60 and linac MVCT measurements were obtained with a first generation benchtop CT imager; the KVCT measurements were obtained using a Philips AcQSim CT Simulator). Phantoms containing various inserts ranging in density from air, through lung, soft tissue and bone equivalent materials and extending to high atomic number metals were imaged with the three modalities. The results enable characterization of image artifacts, CT number linearity and beam hardening. The MVCT images have sufficient contrast that soft tissue regions with 2.8% difference in electron density can be visualized. In MVCT, a linear relationship between CT numbers and electron densities extends to materials with Z ~ 60. In the 4MV CT imaging there is a position dependence of the CT numbers within a uniform water phantom, which is absent in Co-60 CT images, indicating the presence of beam hardening artifacts in the linac MVCT images. The differences between kVCT and MVCT will be discussed considering the variation of the photon interactions dominating the images. Our investigations indicate that MVCT has properties that may potentially extend its utility beyond radiation therapy.

  8. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  9. Computed tomography findings in fibrosing mediastinitis

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, A. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)]. E-mail: a.devaraj@rbht.nhs.uk; Griffin, N. [Department of Radiology, Chelsea and Westminster Hospital, London (United Kingdom); Nicholson, A.G. [Department of Histopathology, Royal Brompton Hospital, London (United Kingdom); Padley, S.P.G. [Departments of Radiology, Royal Brompton Hospital, London (United Kingdom)

    2007-08-15

    Aim: To describe the CT features of fibrosing mediastinitis. Materials and methods: The clinical notes, histology, and CT images from 12 patients with fibrosing mediastinitis were reviewed. Clinical data regarding the presentation and suspected aetiology were correlated with location of mediastinal disease, calcification, effect on mediastinal structures, and additional pulmonary findings on computed tomography (CT). Results: The mean age was 40.5 years, with seven female and five male patients. The most common presenting symptom was shortness of breath. Fibrosing mediastinitis diffusely infiltrated the mediastinum in five patients and was localized in seven. Calcification was present in two cases. Eleven of 12 cases had narrowing of mediastinal structures, including five with pulmonary artery narrowing, five with superior vena cava obstruction, four with bronchial narrowing, three with tracheal narrowing, and one with narrowing of the pulmonary vein. The disease was considered idiopathic in seven cases with a demonstrable aetiology in five cases. Eight out of 12 patients had additional pulmonary findings, including all patients with a known aetiology. Conclusions: In the present series of patients, fibrosing mediastinitis more commonly presented as a localized mediastinal mass than as diffuse mediastinal disease, with the anterior mediastinal compartment most frequently involved. Most cases were idiopathic compared with the majority of previous cases at this institution being ascribed to tuberculosis. There is a high incidence of concomitant pulmonary findings, in particular when an identifiable aetiology is present. Obstruction of vital structures frequently gives rise to complications.

  10. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  11. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  12. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  13. Dose profile in computed tomography chest scan

    International Nuclear Information System (INIS)

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58±5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  14. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  15. Computed tomography and magnetic resonance colonography

    International Nuclear Information System (INIS)

    Colon cancer is the second leading cause of cancer death in the western world. Adenomatous colorectal polyps, which are found in 30-50% of Americans more than 50 years old, are recognized as important precursors of malignancy. Probably most of the invasive colon carcinomas arise from polyps. For this reason an early detection of these polyps and their complete removal is a recognized strategy for the prevention of colon cancer. So far no single method for an early diagnois of colon polyps or colon cancer offers high sensitivity and specificity along with low cost and good patient accccf Endo-opic colonoscopy allows the accurate detection of very small lesions and has since almost completely replaced fluooscopy. Cross-sectional imaging techniques, including magnetic resonance imaging (MRI) and computed tomography (CT), are increasingly being considered imaging modalities for the detection of colorectal polyps. CT and MR colonography are new techniques for imaging of the colon. In symptomatic patients, these new techniques show promising results for the detection of polyps equal to or larger than 1 cm in diameter. (author)

  16. Computed tomography imaging and angiography - principles.

    Science.gov (United States)

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. PMID:27432657

  17. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  18. Computed tomography experiments of Pantex high explosives

    Science.gov (United States)

    Perkins, D. E.; Martz, H. E.; Hester, L. O.; Sobczak, G.; Pratt, C. L.

    1992-04-01

    X-ray computed tomography is an advanced imaging technique which provide three-dimensional nondestructive characterization of materials, components and assemblies. The CT Project group at Lawrence Livermore National Laboratory (LLNL) and the Pantex Plant are cooperating to examine the use of CT technology to inspect and characterize high-explosives pressings (e.g., PBX-9502, LX-10-2). High-explosives pressings manufactured by Pantex must be characterized prior to assembling into weapons systems; a nondestructive examination of all assembly parts would be preferable to the current sampling and destructive testing. The earlier in the processing cycle this can be done the more cost effective it will be. We have performed experiments that show that this characterization can be performed at the pressed billet stage using CT. We have detected 2-mm inclusions in a 15-cm diameter billet and 3.5-mm voids in a 20-cm diameter billet. Based on these results we show calculations that can be used to design production CT systems for characterization of high-explosives.

  19. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  20. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  1. Computed tomography findings in pancreas divisum

    International Nuclear Information System (INIS)

    In 29 patients with abdominal pain the diagnosis of pancreas divisum (PD) was verified by endoscopic retrograde pancreatography (EPR) via both the major and the minor papilla. Computed tomography (CT) was done in all patients to evaluate contour, volume, antero-posterior diameters and attenuation values of the gland in comparison with a normal reference series. Also, the validity of the CT grading of pancreatitis was assessed in comparison with ERP grading. Patients with PD had an increased cranio-caudal diameter of the pancreatic head (p<0.001). Further, the main pancreatic duct was visualized more often in patients with PD (p<0.01), who also had an increasing frequency of pancreatic calcifications (p<0.05). Otherwise there were no differences compared with the normal series. The observed reduction in the volume of the gland in patients with marked pancreatitis at ERP seemingly reflected the severity of inflammation. No cleavage between the dorsal and ventral anlage was identified. CT was found to be too unspecific to be of any use in grading of pancreatitis. In conclusion, CT findings in patients with PD are sparse, unspecific and preferably a reflection of pancreatitis, if present. ERP remains the ''gold standard'' for the diagnosis. (orig.)

  2. Relevance of computed tomography in gynecological tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, J.R.; Hagemann, J.

    1983-11-01

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography.

  3. Relevance of computed tomography in gynaecological tumors

    International Nuclear Information System (INIS)

    1. Abdominal CT examination is the method of choice when examining ovarial tumours. 2. Abdominal CT is redundant in the early stages of carcinoma of the collum and if the carcinoma has penetrated into the vagina. 3. In advanced stages of carcinoma of the collum, CT enables accurate staging. CT is at least equal in relevance to gynaecological examination in respect of assessment of parametraneous infiltration. Distant metastases, as well as complications of the efferent urinary tract can be visualized. In view of this, the following procedure appears meaningful in advanced carcinoma of the collum: First of all, gynaecological examination is performed without anaesthesia to confirm the findings in the regions of the portio and vagina; as far as possible, the existence of the central parametraneous infiltrations is confirmed. For the purpose of further staging of the parametraneous infiltration, as well as of the paraaortal lymphomas and possible metastases, as well as for the purpose of excluding hydronephrosis, computed tomography is performed. This avoids burdening the patient with an examination under anaesthesia, and it also avoids invasive examination methods, such as urography and lymphography. (orig.)

  4. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  5. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  6. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  7. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  8. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  9. Application of optical coherence tomography based microangiography for cerebral imaging

    Science.gov (United States)

    Baran, Utku; Wang, Ruikang K.

    2016-03-01

    Requirements of in vivo rodent brain imaging are hard to satisfy using traditional technologies such as magnetic resonance imaging and two-photon microscopy. Optical coherence tomography (OCT) is an emerging tool that can easily reach at high speeds and provide high resolution volumetric images with a relatively large field of view for rodent brain imaging. Here, we provide the overview of recent developments of functional OCT based imaging techniques for neuroscience applications on rodents. Moreover, a summary of OCT-based microangiography (OMAG) studies for stroke and traumatic brain injury cases on rodents are provided.

  10. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  11. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Aparici, Carina Mari; Win, Aung Zaw

    2016-01-01

    We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT) showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG)-positron emission tomography (PET)/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results. PMID:27625897

  12. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  13. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  14. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    International Nuclear Information System (INIS)

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  15. Diagnosis of hoof disease in horses using computed tomography

    Directory of Open Access Journals (Sweden)

    Kovač Milomir

    2002-01-01

    Full Text Available This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Germany of 39 horses with hoof diseaseas. The most frequently findings were the navicular syndrome (eight horses, laminitis (seven horses, keratnoma (six horses and ossification of collateral cartilages in the distal phalanx (four horses. The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography.

  16. Cerebral computed tomographic angiography scan delay in subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Lukosevicius Saulius

    2005-01-01

    Full Text Available CONTEXT: Computed tomographic angiography (CTA is widely applied in the evaluation of cerebral vessels. Contrast enhancement in cerebral CTA without care or test bolus is not always sufficient for high-quality images. AIMS: Evaluation of the possibilities of calculation of scan delay for cerebral CTA in case of subarachnoid hemorrhage (SAH, based on clinical data of a patient and to find out prognostic error of the model. SETTINGS AND DESIGN: Prospective study in Neurosurgery and Radiology departments. MATERIALS AND METHODS: Scan delay in 53 patients suffering an acute SAH was measured employing test bolus technique. Cerebral CTA was performed afterwards. STATISTICAL ANALYSIS USED: SPSS for Windows v.10.1 software package was applied for dispersion analysis, including one-sample Kolmogorov-Smirnov′s test and Levene′s Test of Equality of Error Variances. RESULTS: A statistical model for the prediction of scan delay in SAH was developed. Cerebral CTA scan delay was dependent upon age, neurological status and impact of the latter factors together (P<0.05. The determined mean square error of prognosis of scan delay of the developed model equals 3.3 sec. CONCLUSION: Using our proposed model it is possible to estimate an optimal delay time for CTA in most patients with SAH with a determined error.

  17. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Science.gov (United States)

    Miura, You; Seto, Akira; Kanazawa, Minoru; Nagata, Makoto

    2016-01-01

    Cerebral and cerebellar symptoms are frequently associated with Legionnaires' disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT) or magnetic resonance imaging (MRI). We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT) showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires' disease.

  18. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography.

    Science.gov (United States)

    Ohta, Hiromitsu; Yamazaki, Susumu; Miura, You; Seto, Akira; Kanazawa, Minoru; Nagata, Makoto

    2016-01-01

    Cerebral and cerebellar symptoms are frequently associated with Legionnaires' disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT) or magnetic resonance imaging (MRI). We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT) showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires' disease. PMID:27478660

  19. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hiromitsu Ohta

    2016-01-01

    Full Text Available Cerebral and cerebellar symptoms are frequently associated with Legionnaires’ disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT or magnetic resonance imaging (MRI. We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires’ disease.

  20. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  1. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  2. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present s...

  3. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  4. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  5. Cerebello-cerebral functional relationship in spinocerebellar degeneration using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koshi, Yasuhiko; Kitamura, Shin; Sakayori, Osamu; Komaba, Yuichi; Terashi, Akiro [Nippon Medical School, Tokyo (Japan)

    1995-07-01

    In order to investigate the laterality of cerebellar ataxia and its influence for the cerebral cortex in spinocerebellar degeneration (SCD), regional cerebral blood flow (rCBF) was measured using positron emission tomography (PET) in 10 patients with sporadic olivopontocerebellar atrophy (sOPCA), 7 patients with hereditary SCD (hSCD), and 10 age matched control subjects. The laterality of cerebellar ataxia was evaluated by the total score of the difference between left and right limbs of three limb-coordination tests. The lateralities of rCBF were calculated by asymmetry indices (AIs) of each region of interest in the cerebellum, thalamus, caudate, putamen, cerebral cortices. The laterality of cerebellar ataxia was significantly correlated with AI in the cerebellum in patients with sOPCA. Furthermore, significant negative correlations were observed between AI in the cerebellum and each AI in the thalamus, frontal cortex in patients with sOPCA. However, no correlations were observed between AI in the cerebellum and the other AIs in controls and patients with h SCD. Duration of illness in patients with sOPCA with laterality is shorter than that in patients without laterality. These results suggest that the existence of crossed cerebello-cerebral diaschisis (CCCD) resulting from transneuronal deactivation through cerebello-thalamo-cerebral pathway in patients with the early stage of sOPCA with laterality. (author).

  6. Determination of cerebral metabolic patterns in dementia using positron emission tomography

    International Nuclear Information System (INIS)

    With the introduction of the Kety-Schmidt method whole brain measurements of blood flow and metabolism were first applied to normal aged and demented patients. Chronically demented patients were consistently found to have marked reductions in cerebral blood flow, oxygen utilization, and glucose utilization when dementia was severe, and lesser reductions when it was mild. Others found that cerebral blood flow, oxygen utilization, and glucose utilization were decreased in parallel in late stages of Alzheimer's disease (AD) and multiple infarct dementia (MID). The intraarterial /sup 133/Xe method has been used to determine abnormalities in regional cerebral blood flow that correlate with cognitive deficits in patients with organic dementia, mostly Alzheimer's cases. Positron emission tomography (PET) and the /sup 18/F fluorodeoxyglycose (FDG) method have been applied to small numbers of demented patients with advanced AD. In general, decreases were found in global cerebral glucose utilization, but especially in temporal and parietal cortex. Others, using PET and the /sup 15/O/sub 2/ steady-state method, found a coupled decline in global cerebral blood flow and oxygen utilization that was correlated with increasing severity of dementia in both AD and MID, but there was no increase in oxygen extraction ratio, and therefore no evidence to support the existence of a chronic ischemic brain process. In this chapter, the author reviews some of the recent findings at UCLA using PET and the method in the study of normal aging and dementing disorders

  7. Single photon emission computed tomography in Alzheimer's disease. Abnormal iofetamine I 123 uptake reflects dementia severity

    International Nuclear Information System (INIS)

    To determine whether abnormalities in regional cerebral functional activity estimated by iofetamine hydrochloride I 123 and single photon emission computed tomography can be detected in mild or moderate as well as severe cases of Alzheimer's disease (AD), we performed iofetamine I 123-single photon emission computed tomography in 37 patients with probable AD (nine patients with mild, 18 patients with moderate, and ten patients with severe dementia) and nine age-matched control subjects. Iofetamine I 123 uptake was measured in right and left frontal, temporal, parietal, and occipital cortices. Mean (right and left) iofetamine I 123 activity was lowest in the parietal region of patients with AD and was significantly reduced in the other three regions compared with control subjects. Only in the parietal region was lower relative iofetamine I 123 activity associated with an impaired level of patient function and with cognitive deficit

  8. Cerebral toxoplasmosis in AIDS - computerized tomography evaluation; Toxoplasmose cerebral na SIDA - avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Regina Coeli Fonseca [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Hospital Universitario Antonio Pedro. Servico de Radiologia; Narchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia

    1999-06-01

    Cerebral toxoplasmosis is a disease that affects many AIDS's patients. FOr this paper 46 patients with confirmed cases of cerebral toxoplasmosis who did a CT scan between March, 1994 and September, 1997 were examined. Single lesions were found in 28.3% of the patients. The lesions were more frequently detected in the basal ganglia and the frontal lobes. No lesion was larger than 4 cm. As regards the contrast enhancing of the lesions on a CT scan we observed that 54.5% of the lesions had a ring-like contrast enhancing, 36.4% had a nodular contrast enhancing and 6% had a heterogeneous form. After the 21st day of treatment we noticed an improvement in the aspect of the patients'lesions. The improvement of the lesions could be seen through a reduction of the edematous halo, a reduction of the lesion size and a modification in the contrast enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility with cerebral toxoplasmosis, as well as to monitor these patients during treatment. (author)

  9. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  10. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  11. Dose modulated computed tomography automated dosimetry

    International Nuclear Information System (INIS)

    Full text: Computed Tomography (CT) scans contribute a significant portion of the effective radiation dose from medical procedures and generally large effective radiation doses per diagnostic examination. With the advent of Multislice CT, the potential for large radiation exposures increased. This combined with the appeal of the resultant isotropic imaging and the increasing number of applications for which CT could be utilised (including screening procedures) has further increased the need for vigilant monitoring of CT protocols and use with respect to radiation dose. The introduction of dose modulated Computed Tomography has proven an effective method for reducing patient dose and is now widely used by CT manufacturers. This involves lowering the mA when scanning through anatomical regions which do not require a large mA. Many CT investigations now utilise dose modulation. Some of these studies will include over 900 images for which the mA and occasionally other factors could vary. In order to utilise the existing software to perform CT dosimetry a program has been written to automatically extract scan parameters from CT dicom image files and apply the ImPACT CT Patient Dosimetry Calculator, for slices with differing factors. Matlab has been used to write and compile a program which sorts through a folder of dicom images and extracts the appropriate dicom header information. Some manufacturers store different series and reformatted images all within the same folder. The images of the CT study for which the dosimetry is to be performed must be stored within the one folder and must be in a dicom format. The program has been written to accommodate several manufacturers, which all contain different information in their dicom headers. The Matlab program groups the various study/image types, extracting the relevant dicom header information, which is written to an Excel worksheet. An Excel file uses this information to run the ImPACT CT Patient Dosimetry Calculator with

  12. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  13. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  14. Computed tomography of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    This article summarizes our preliminary results on high resolution computed tomography of 101 patients with various diffuse lung diseases. Instead of pattern recognition routinely done on chest radiogram (nodular, reticular or reticulo-nodular) we emphasized the relation of the lesions with inherent structures of the lung seen on the CT images. For this purpose our ten years radiologic-pathologic correlation on inflated and fixed lung specimens proved quite useful. 1) Centrilobular inflammatory nodules. This was seen in diffuse panbronchiolitis (DPB), allergic broncho-pulmonary aspergillosis, tuberculosis, pneumoconiosis and lobular pneumonia. DPB and bronchogenic spread of tuberculosis were most representative. The nodules produced by these diseases were located at the extreme end of bronchial branchings and separated by 2 to 3 mm from the pleura and pulmonary vein which constitute the edge of the secondary pulmonary lobule. 2) The lesions extending along bronchoarterial sheath and pulmonary vein. The contours of the pulmonary vessels were irregular and their calibers enlarged. These findings were seen in sarcoidosis and lymphangiosis carcinomatosa. 3) Lobular and multilobular lesions. This was seen in diffuse interstitial pneumonia and in alveolar filling diseases. The margins of the lesions were straight or curved slightly suggesting that disease is blocked by the lobular septa. Fine air bronchogram within the lesions was characteristic in chronic interstitial pneumonia. 4) Slight to moderate increase of lung density with multilobular distribution. This was seen in interstitial pneumonia, sarcoidosis and hypersensitivity pneumonitis. We supposed that this finding corresponds to cellular or fibrous thickening of alveolar septa, but direct proof was not available. (J.P.N.)

  15. Computed tomography in Duchenne type muscular dystrophy

    International Nuclear Information System (INIS)

    The computed tomography (CT) scan was performed on 91 Duchenne type muscular dystrophy (DMD) patients on the following four levels; (1) at the level of L3 vertebra, (2) 2-3cm above the symphysis pubica, (3) midposition of the thigh, (4) largest-diameter section of the lower leg. The CT of muscles common to most of the DMD patients were as follows: 1. Muscle atrophy: Muscle atrophy was shown as a reduction in the cross-sectional area of the muscles. Very mild muscle atrophy could be detected either by the clearly identified muscle border or by scattered low-density areas of so-called ''moth-eaten'' appearance within muscles. 2. Fat infiltration: The decrease in radio-density of muscles was interpreted as infiltration of fatty tissue. This type of density change was further classified into diffuse, streaked, cobblestone and salt-and-pepper patterns according to the spacial distribution of low-density areas. 3. Selectivity pattern: As the chronological sequence of DMD muscle degeneration is usually different among individual muscles, it may be seen, in some stages, that some of the synergistic muscles are still only slightly involved, while the others are quite severely atrophied with evident fat infiltration. In certain stages of the disease, most of the patients show relative preservation of particular muscles although they assumed a rounded shape. The most resistent muscle was musculus gracilis, followed by the musculus sartorius, musculus semitendinosus (and/or musculus semimembranosus) in that order. According to the severity of the CT changes, 86 of the 91 patients were classed into five stages from A1 to A5. Morphological stages (A1-A5) were well correlated to the functional disability stages by Ueda with a correlation factor of r=0.88. (J.P.N.)

  16. Characterization of HPGe detectors using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hedman, A., E-mail: Angelica.Hedman@foi.se [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Bahar Gogani, J.; Granström, M. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Johansson, L.; Andersson, J.S. [Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Ramebäck, H. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-41296 Göteborg (Sweden)

    2015-06-11

    Computed Tomography (CT) high-resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38±0.07) mm for the n-type detector and by (0.40±0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (<5 cm). In the energy range of 40–700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9–2.9% for the n-type detector and 0.3–2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40–700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2–7.1% for the n-type detector and 0.2–1.0% for the p-type detector, i.e. the detector efficiency is overestimated using data available by the manufacturer.

  17. Dose in x-ray computed tomography.

    Science.gov (United States)

    Kalender, Willi A

    2014-02-01

    Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment. PMID:24434792

  18. Cerebral amobarbital sodium distribution during Wada testing: utility of digital subtraction angiography and single-photon emission tomography

    International Nuclear Information System (INIS)

    We aimed to determine if the cerebral distribution of anesthetic during Wada testing is reflected by findings on digital subtraction angiography (DSA) and single-photon emission computed tomography (SPECT) and if the findings on these studies are relevant to the outcome of the Wada test. We carried out selective internal carotid artery (ICA) DSA on 29 patients underwent studies prior to a Wada test. In patients without angiographic cross-filling, amobarbital and a radiotracer were injected into each ICA, beginning with the epileptogenic side. In patients with cross-filling, the ICA ipsilateral to the epileptogenic focus was injected with amobarbital and radiotracer while other was injected with amobarbital alone. We analyzed the DSA studies for cross-filling and filling of the posterior cerebral arteries (PCA). We reviewed the SPECT for activity in the territories of the anterior, middle cerebral, and posterior cerebral arteries. We compared the results of both studies with the success or failure of the neuropsychological portion of the Wada test. In 20 patients without cross-filling, the results of DSA and SPECT were comparable: symmetrical hemisphere activity was seen. In nine patients with cross-filling, SPECT showed bilateral, almost symmetrical activity. Filling or nonfilling of the PCA correlated with activity (or lack of it) in the medial temporal and occipital regions in all patients. The Wada test was considered successful in all patients. The findings on SPECT did not alter interpretation of the Wada test and we suggest that it may not be needed in all patients undergoing Wada testing. (orig.)

  19. Cerebral amobarbital sodium distribution during Wada testing: utility of digital subtraction angiography and single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Mukherji, S.K.; McCartney, W.H. [Department of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-11-01

    We aimed to determine if the cerebral distribution of anesthetic during Wada testing is reflected by findings on digital subtraction angiography (DSA) and single-photon emission computed tomography (SPECT) and if the findings on these studies are relevant to the outcome of the Wada test. We carried out selective internal carotid artery (ICA) DSA on 29 patients underwent studies prior to a Wada test. In patients without angiographic cross-filling, amobarbital and a radiotracer were injected into each ICA, beginning with the epileptogenic side. In patients with cross-filling, the ICA ipsilateral to the epileptogenic focus was injected with amobarbital and radiotracer while other was injected with amobarbital alone. We analyzed the DSA studies for cross-filling and filling of the posterior cerebral arteries (PCA). We reviewed the SPECT for activity in the territories of the anterior, middle cerebral, and posterior cerebral arteries. We compared the results of both studies with the success or failure of the neuropsychological portion of the Wada test. In 20 patients without cross-filling, the results of DSA and SPECT were comparable: symmetrical hemisphere activity was seen. In nine patients with cross-filling, SPECT showed bilateral, almost symmetrical activity. Filling or nonfilling of the PCA correlated with activity (or lack of it) in the medial temporal and occipital regions in all patients. The Wada test was considered successful in all patients. The findings on SPECT did not alter interpretation of the Wada test and we suggest that it may not be needed in all patients undergoing Wada testing. (orig.)

  20. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine

  1. Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

    International Nuclear Information System (INIS)

    A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 μm was obtained at the spatial frequency of 4.3 μm-1 according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

  2. Evaluation of intracerebral hematoma resorption dynamics with computed tomography

    International Nuclear Information System (INIS)

    High mortality and severe grade of disability observed in patients after intracerebral hemorrhage provide efforts to improve diagnostics and therapy of the hemorrhagic cerebral stroke. An aim of this paper was an evaluation of blood resorption dynamics in patients with intracerebral hematoma, performed with computed tomography of the head and an analysis of clinical significance of this process. An examined group included 133 patients with intracerebral hematoma proven by a CT exam. In 97 patients resorption of the hematoma was measured, based on control scans taken on 15th and 30th day on average. Volume of the hemorrhagic foci was measured as well as the width of ventricles and the displacement of medial structures. The mean hematoma volume reached 11,59 ml after 15 days, and 3,16 m after 30 days (average decrease of the volume 0,67 ml/day). There was a significant difference in the rate of resorption between the first (0-15 days) and the second (15-30 days) observation period - 0,78 and 0,62 ml/day respectively. The dynamics of the process was dependent on volume and localization of the hematoma and independent of the grade of displacement and compression of the ventricles. The calculated mean rate of the hematomas resorption enables to schedule control examinations precisely. The significant differences of the dynamics of blood resorption depending on hematomas size and the independence of compression and displacement of ventricular system suggest, that the most important factor in therapeutic decision-making should be a clinical status of the patient. (author)

  3. Skeletal dosimetry in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Walters, B. R. B.; Ding, G. X.; Kramer, R.; Kawrakow, I. [Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada); Department of Radiation Oncology, Vanderbilt-Ingram Cancer Center, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-5671 (United States); Departamento de Energia Nuclear, Universidade Federal de Pernambuco, Avenida Professor Luiz Freire 1000, Cidade Universitaria, CEP 50740-540, Recife, Pernambuco (Brazil); Ionizing Radiation Standards, National Research Council of Canada, Ottawa K1A OR6 (Canada)

    2009-07-15

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm{sup 3}, with 17x17x17 {mu}m{sup 3} microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens ({approx}8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only {approx}50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  4. Skeletal dosimetry in cone beam computed tomography.

    Science.gov (United States)

    Walters, B R B; Ding, G X; Kramer, R; Kawrakow, I

    2009-07-01

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12 x 0.12 x 0.12 cm3, with 17 x 17 x 17 microm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/ MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (approximately 8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only approximately 50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment. PMID:19673190

  5. Skeletal dosimetry in cone beam computed tomography

    International Nuclear Information System (INIS)

    Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm3, with 17x17x17 μm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (∼8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only ∼50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

  6. Marked reduction of cerebral oxygen metabolism in patients with advanced cirrhosis; A positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Kawatoko, Toshiharu; Murai, Koichiro; Ibayashi, Setsurou; Tsuji, Hiroshi; Nomiyama, Kensuke; Sadoshima, Seizo; Eujishima, Masatoshi; Kuwabara, Yasuo; Ichiya, Yuichi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-01-01

    Regional cerebral blood flow (rCBF), cerebral metabolic rate of oxygen (rCMRO{sub 2}), and oxygen extraction fraction (rOEF) were measured using positron emission tomography (PET) in four patients with cirrhosis (two males and two females, aged 57 to 69 years) in comparison with those in five age matched controls with previous transient global amnesia. PET studies were carried out when the patients were fully alert and oriented after the episodes of encephalopathy. In the patients, rCBF tended to be lower, while rCMRO{sub 2} was significantly lowered in almost all hemisphere cortices, more markedly in the frontal cortex. Our results suggest that the brain oxygen metabolism is diffusely impaired in patients with advanced cirrhosis, and the frontal cortex seems to be more susceptible to the systemic metabolic derangements induced by chronic liver disease. (author).

  7. Personal computer aided cerebral perfusion imaging with dynamic CT

    Institute of Scientific and Technical Information of China (English)

    林燕; 高培毅

    2004-01-01

    @@Reports on the clinical implementation of dynamic computerised tomography (CT) perfusion imaging and quantitative measurement have increased dramatically of late.1-8 The advantages of dynamic CT perfusion imaging and quantitative measurement for the diagnosis of acute cerebral infarction have been acknowledged. However, most overseas CT vendors set perfusion imaging software package as an option for graphic workstation at a too high price for domestic practitioners. To foster the domestic implementation and development of this new technology, we have extended the earlier work.1,2 Applying the theory of central volume principle to DICOM 3.0 standard forms of prime CT images, we developed dynamic CT perfusion imaging and quantitative measure-ment programmes for PCs using Visual C+ + in Windows 98 system.

  8. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.

  9. Study on cranial computed tomography in infants and children with central nervous system disorders, 2

    International Nuclear Information System (INIS)

    110 patients with cerebral palsy were studied by cranial computed tomography (CT) and electroencephalography (EEG) and the following results were obtained: 1) Abnormal brain findings on CT were present in 69% of spastic quadriplegia type, in 75% of spastic hemiplegia type, in 23% of athetotic type and in 50% of mixed type. 2) Most patients with spastic quadriplegia revealed diffuse cerebral atrophy and patients with spastic hemiplegia mostly showed hemispherial cerebral atrophy at the contralateral side to the motor paralysis on CT. Most patients with athetotis revealed normal CT-findings, but a few indicated slight diffuse cerebral atrophy on CT. 3) The severer was mental retardation of the patients, the more frequent and severer were CT-abnormalities. 4) Patients with epileptic seizure showed CT-abnormalities more often than patients without the seizure. 5) There was a good correlation between the abnormality of background activities on EEG and that on CT, in which their laterality coincided in most cases. 6) Sides of seizure discharges on EEG were the same as those of CT-abnormalities in 1/3 to 1/2 of patients, but the localization of seizure discharges corresponded to that of CT-abnormalities only in 11% of the cases. (author)

  10. Cerebrospinal fluid analysis detects cerebral amyloid-β accumulation earlier than positron emission tomography

    OpenAIRE

    Palmqvist, Sebastian; Mattsson, Niklas; Hansson, Oskar; ,

    2016-01-01

    See Rabinovici (doi:10.1093/brain/aww025) for a scientific commentary on this article. Cerebral accumulation of amyloid-β is thought to be the starting mechanism in Alzheimer’s disease. Amyloid-β can be detected by analysis of cerebrospinal fluid amyloid-β42 or amyloid positron emission tomography, but it is unknown if any of the methods can identify an abnormal amyloid accumulation prior to the other. Our aim was to determine whether cerebrospinal fluid amyloid-β42 change before amyloid PET ...

  11. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E;

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...... subjects using three different MRI techniques: arterial spin labeling (ASL), dynamic contrast enhanced T1 weighted perfusion MRI (DCE) and phase contrast mapping (PCM). All MRI measurements were performed within the same session. In 10 of the subjects repeated CBF measurements by (15) O labeled water PET...

  12. In vivo photoacoustic tomography of mouse cerebral edema induced by cold injury

    Science.gov (United States)

    Xu, Zhun; Zhu, Quing; Wang, Lihong V.

    2011-06-01

    For the first time, we have implemented photoacoustic tomography (PAT) to image the water content of an edema in vivo. We produced and imaged a cold-induced cerebral edema transcranially, then obtained blood vessel and water accumulation images at 610 and 975 nm, respectively. We tracked the changes at 12, 24, and 36 h after the cold injury. The blood volume decreased after the cold injury, and the maximum area of edema was observed 24 h after the cold injury. We validated PAT of the water content of the edema through magnetic Resonance Imaging and the water spectrum from the spectrophotometric measurement.

  13. Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Faccioli, Niccolo; Foti, Giovanni; Barillari, Marco; Mucelli, Roberto Pozzi [University of Verona, Department of Radiology, G.B. Rossi Hospital, Verona (Italy); Atzei, Andrea [University of Verona, Department of Hand Surgery, G.B. Rossi Hospital, Verona (Italy)

    2010-11-15

    To compare the diagnostic accuracy and radiation exposure of cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) in the evaluation of finger fractures. In a 3-year period, 57 consecutive patients with post-traumatic fractures of the metacarpal-phalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints with involvement of the articular surface were studied by means of CBCT and MSCT. Student's t test was used to compare CBCT and MSCT accuracy in evaluating the percentage of joint surface involvement and in detecting bone fragments. The average tissue-absorbed doses of CBCT and MSCT were also compared. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated. In all cases, CBCT allowed the percentage of articular involvement to be correctly depicted compared with MSCT, showing 100% sensitivity and specificity (p < 0.001). A total of 103 bone fragments were depicted on MSCT (mean 3.8 per patient, range 1-23). CBCT indicated 92 out of 103 fragments (89.3%) compared with MSCT (mean diameter of missed fragments 0.9 mm, range 0.6-1.3 mm), with no statistically significant difference between CBCT and MSCT (p < 0.025). Multislice CT radiation exposure was significantly higher than that of CBCT (0.18 mSv vs 0.06 mSv, p < 0.0025). Inter-observer agreement was good (overall {kappa} = 0.89-0.96). Cone beam CT may be considered a valuable imaging tool in the preoperative assessment of finger fractures, when MSCT is not available. (orig.)

  14. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Science.gov (United States)

    Wong, Ka-Kit; Gandhi, Arpit; Viglianti, Benjamin L; Fig, Lorraine M; Rubello, Domenico; Gross, Milton D

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography (SPECT)/computed tomography (CT) hybrid imaging for diagnosis of various endocrine disorders. METHODS: We performed MEDLINE and PubMed searches using the terms: “SPECT/CT”; “functional anatomic mapping”; “transmission emission tomography”; “parathyroid adenoma”; “thyroid cancer”; “neuroendocrine tumor”; “adrenal”; “pheochromocytoma”; “paraganglioma”; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts (case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology. RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the bio-distribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTc- labeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol (NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma. CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy

  15. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    International Nuclear Information System (INIS)

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions

  16. Noninvasive xenon-133 measurements of cerebral blood flow using stationary detectors compared with dynamic emission tomography

    DEFF Research Database (Denmark)

    Schroeder, T; Vorstrup, S; Lassen, N A;

    1986-01-01

    Repeated bedside measurements of CBF have been made possible by the recent development of a mobile unit with 10 stationary detectors using the intravenous xenon-133 method. To evaluate this technique, comparative CBF studies at rest and following the application of a cerebral vasodilatory stimulus...... (acetazolamide, 1 g i.v.) were performed with the mobile equipment and with xenon-133 single-photon emission inhalation tomography in patients with cerebrovascular disease. The CBF level and the flow response to acetazolamide as determined with the two methods were well correlated, although at low flow levels...... the stationary detectors yielded somewhat lower CBF values than did emission tomography. Considering the side-to-side asymmetry, an excellent correlation was obtained. Using the initial slope index, the stationary detectors revealed quantitatively 83% of the interhemispheric asymmetry and 63% of the asymmetry...

  17. Intracranial blood flow measured with single photon emission computer tomography (SPECT) during transient -6 degrees head-down tilt.

    Science.gov (United States)

    Satake, H; Konishi, T; Kawashima, T; Matsunami, K; Uno, T; Imai, S; Yamada, H; Hirakawa, C

    1994-02-01

    Regional cerebral blood flow (CBF) during a transient head-down tilt of -6 degrees (-6 degrees HDT) was measured with single photon emission computer tomography (SPECT). CBF was measured and averaged for both sides of the brain areas; e.g., the bilateral anterior cerebral artery (bACA) area, the middle cerebral artery (bMCA) area, the posterior cerebral artery (bPCA) area, bilateral basal ganglia, and the cerebellum. Among these areas, a significant increase in CBF was observed in the basal ganglia and the cerebellum during -6 degrees HDT compared to pre-HDT. When CBF was measured separately in the left or right brain area, these significances disappeared, although a trend of increase or decrease was still observable. A trend of increase was observed in the left anterior cerebral artery (IACA) area, the right middle cerebral artery (rMCA) area, the right posterior cerebral artery (rPCA) area, the left and right basal ganglia, and the cerebellum. In rACA, IMCA and IPCA areas, a slight decrease in CBF was observed. At the same time, cardiac parameters were measured. Heart rate (HR), stroke volume (SV) and cardiac output (CO) did not change significantly, although SV slightly increased and HR slightly decreased during -6 degrees HDT.

  18. Computed tomography in penetrating injury to the eye.

    Science.gov (United States)

    Bhimani, S; Virapongse, C; Sarwar, M; Twist, J F

    1984-05-01

    We used computed tomography to detect and localize foreign bodies in two unusual cases of penetrating injury to the eyes. In one case, a large broken twig appeared to have penetrated the globe and the inferior rectus muscle; in the other, the globe was ruptured by many glass shards . In the first case surgery showed the computed tomographic impression to be incorrect. The globe and the inferior rectus muscle were intact and vision and motility were normal postoperatively. In the second case, swelling made direct visualization impossible, and computed tomography was used to locate the foreign bodies. PMID:6720836

  19. Development of a proton Computed Tomography Detector System

    CERN Document Server

    Naimuddin, Md; Blazey, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rukalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P

    2015-01-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  20. Development of a proton Computed Tomography detector system

    International Nuclear Information System (INIS)

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector

  1. Coronary computed tomography angiography indicates complexity of percutaneous coronary interventions

    OpenAIRE

    Stähli, B E; Bonassin, F; Goetti, R; Küest, S M; Frank, M.; Altwegg, L A; Gebhard, C; Levis, A; Wischnewsky, M. B.; Lüscher, T F; Alkadhi, H.; Kaufmann, P A; Maier, W.

    2012-01-01

    BACKGROUND: Coronary computed tomography angiography (CCTA) provides information regarding lesion morphology and three-dimensional coronary anatomy incremental to coronary angiography. We addressed the question whether preprocedural CCTA bears potential for guiding percutaneous coronary interventions (PCI). METHODS AND RESULTS: Sixty-six coronary lesions attempted with PCI within 6 months of preprocedural CCTA were retrospectively assessed. Lesion parameters from unenhanced computed tomogr...

  2. 3D neutron computed tomography. Requirements and applications

    International Nuclear Information System (INIS)

    Other than X-rays, neutrons can penetrate most metals easily while delivering a high contrast for many light-weight elements. Especially their high sensitivity for hydrogen makes them a valuable tool for the detection of organic materials like lubricants, plastics or sealants within metal housings. Neutron radiography and tomography complement the application of X-ray for the inspection of complex and critical components like in automotive and aerospace applications. An overview about the technical and mathematical differences between neutron and X-ray tomography is given and the imperfections and limitations of a neutron setup are shown. Several examples of technical neutron computed tomography are given. (author)

  3. Human cerebral acetylcholinesterase activity measured with positron emission tomography: procedure, normal values and effect of age

    International Nuclear Information System (INIS)

    The regional cerebral metabolic rate of [11C]N-methyl-4-piperidyl acetate, which is nearly proportional to regional cerebral acetylcholinesterase (AChE) activity, was measured by dynamic positron emission tomography in 20 healthy subjects with a wide age range (24-89 years). Quantitative measurement was achieved using a kinetic model which consisted of arterial plasma and cerebral tissue compartments. The plasma input function was obtained using thin-layer chromatography and an imaging phosphor plate system at frequent sampling intervals to catch the rapid metabolism of the tracer in the blood. The distribution of the rate constant k3, an index of AChE activity, agreed well with reported post-mortem AChE distribution in the cerebral cortex (0.067-0.097 min-1) and thalamus (0.268 min-1), where AChE activity was low to moderate. The k3 values in the striatum and cerebellum, where AChE activity was very high, did not respond linearly to AChE activity because of increased flow dependency. No significant effect of age was found on AChE activity of the cerebral cortex, suggesting that the ascending central cholinergic system is preserved in normal aging. This study has shown that quantitative measurement of enzyme activity in the living brain is possible through appropriate modelling of tracer kinetics and accurate measurement of the input function. The method should be applicable to patients with Alzheimer's disease and those with other kinds of dementia whose central cholinergic system has been reported to be disturbed. (orig.)

  4. Human cerebral acetylcholinesterase activity measured with positron emission tomography: procedure, normal values and effect of age

    Energy Technology Data Exchange (ETDEWEB)

    Namba, Hiroki [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Division of Neurological Surgery, Chiba Cancer Center, Chiba (Japan); Iyo, Masaomi [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Department of Psychiatry and Neurology, Hamamatsu University School of Medicine, Hamamatsu (Japan); Fukushi, Kiyoshi; Suhara, Tetsuya; Sudo, Yasuhiko; Suzuki, Kazutoshi; Irie, Toshiaki [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Shinotoh, Hitoshi [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Department of Neurology, Chiba University School of Medicine, Chiba (Japan); Nagatsuka, Shin-ichiro [Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan)]|[Tokai Research Laboratories, Daiichi Pure Chemical Co., Ltd., Ibaraki (Japan)

    1999-02-01

    The regional cerebral metabolic rate of [{sup 11}C]N-methyl-4-piperidyl acetate, which is nearly proportional to regional cerebral acetylcholinesterase (AChE) activity, was measured by dynamic positron emission tomography in 20 healthy subjects with a wide age range (24-89 years). Quantitative measurement was achieved using a kinetic model which consisted of arterial plasma and cerebral tissue compartments. The plasma input function was obtained using thin-layer chromatography and an imaging phosphor plate system at frequent sampling intervals to catch the rapid metabolism of the tracer in the blood. The distribution of the rate constant k{sub 3}, an index of AChE activity, agreed well with reported post-mortem AChE distribution in the cerebral cortex (0.067-0.097 min{sup -1}) and thalamus (0.268 min{sup -1}), where AChE activity was low to moderate. The k{sub 3} values in the striatum and cerebellum, where AChE activity was very high, did not respond linearly to AChE activity because of increased flow dependency. No significant effect of age was found on AChE activity of the cerebral cortex, suggesting that the ascending central cholinergic system is preserved in normal aging. This study has shown that quantitative measurement of enzyme activity in the living brain is possible through appropriate modelling of tracer kinetics and accurate measurement of the input function. The method should be applicable to patients with Alzheimer`s disease and those with other kinds of dementia whose central cholinergic system has been reported to be disturbed. (orig.) With 8 figs., 1 tab., 21 refs.

  5. Dose estimation for paediatric cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Curci Daros, K.A.; Bitelli Medeiros, R. [Sao Paulo Univ. Federal (Brazil); Curci Daros, K.A.; Oliveira Echeimberg, J. de [Centro Univ. Sao Camilo, Sao Paulo (Brazil)

    2006-07-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3{<=}p{<=}6 cm, was {rho}((p)=7.9(4)x10{sup -2}+7(5)x10{sup -5}p{sup 4.5(4)} cm{sup -1}; exposed to primary X-ray for the posterior fossa

  6. Evaluating iterative reconstruction performance in computed tomography

    International Nuclear Information System (INIS)

    Purpose: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. Methods: The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d′). d′ was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1–4 mm), contrast levels (10–100 HU), and edge profiles (sharp and soft). Unique d′ values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDIvol: 3.4–64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d′ values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. Results: IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction

  7. Evaluating iterative reconstruction performance in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu, E-mail: chenby04@gmail.com; Solomon, Justin [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Ramirez Giraldo, Juan Carlos [Siemens Healthcare, Malvern, Pennsylvania 19355 (United States); Samei, Ehsan [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Departments of Radiology, Physics, Biomedical Engineering, and Electronic and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2014-12-15

    Purpose: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. Methods: The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d′). d′ was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1–4 mm), contrast levels (10–100 HU), and edge profiles (sharp and soft). Unique d′ values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDI{sub vol}: 3.4–64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d′ values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. Results: IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction

  8. Measurement of regional cerebral blood flow with H215O positron emission tomography during Matas test - report of three cases

    International Nuclear Information System (INIS)

    The authors carried out a Matas test with a regional cerebral blood flow (rCBF) study using H215O positron emission tomography (PET) for three cases of large internal carotid artery aneurysms. There is a likely correlation between the cerebral blood flow (CBF) reduction rate obtained by PET, and the mean stump pressure available from a conventional balloon occlusion test. The advantages of this noninvasive and quantitative method are presented in comparison with other methods. (author)

  9. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  10. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  11. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  12. The current concepts of computed tomography for acute stroke

    International Nuclear Information System (INIS)

    Stroke is one of a leading cause of death and disability worldwide. The major advances in stroke therapy in particular invasive therapy lead to application of new imaging techniques. The aim of this review is to present state-of-the-art concepts of computed tomography for acute stroke. The goals of a neuroimaging in acute stroke are to establish a diagnosis as early as possible and to evaluate brain perfusion and intracranial vessels' patency. State-of-the-art imaging in the era of multidetector computed tomography (CT) with high spatial and temporal resolution consists of multimodal CT imaging. Non enhanced CT is necessary for depiction of hemorrhage or early ischemic signs. CT angiography evaluates intravascular thrombi or significant stenosis, and CT perfusion demonstrates salvageable tissue at risk. By combining different imaging techniques in multimodal approach we can acquire information necessary for therapeutic planning and could select patients for thrombolysis. The imaging protocol should be tailored to the patient regarding to the time of onset, necessity and availability of CT modalities. (authors) Key words: Stroke. Computed Tomography (CT). Computed Tomography Angiography (CTA). Computed Tomography Perfusion (CTP)

  13. Dynamic computed tomography findings in cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Yutaka; Tomoda, Kaname; Kariya, Mitsumasa; Mori, Shigeru; Mitomo, Masanori.

    1988-01-01

    Dynamic CT was performed with 41 patients with the clinically diagnosed cerebrovascular diseases. A visual evaluation based on the dynamic CT images classified six patterns of brain parenchymal enhancement, especially four patterns of which could only be detected by dynamic CT technique. Dynamic CT was proved of great value in detecting regional cerebral tissue filled by collaterals in retrograde fashion because of the occlusion of main arteries, namely brain tissue perfusion of internal carotid occlusion disease and moyamoya disease was best understood by dynamic CT with adequate resolution.

  14. Ruptured intracranial aneurysm during pregnancy with false-negative computed tomography angiography findings: a case report.

    Science.gov (United States)

    Goto, Yukihiro; Ebisu, Toshihiko; Mineura, Katsuyoshi

    2015-06-01

    A 34-year-old female was admitted at 34 weeks of gestation with sudden onset of a severe headache accompanied by vomiting. Neurological examination revealed neck rigidity, and computed tomography (CT) of the brain revealed a subarachnoid hemorrhage (SAH). Although the hemorrhage was located primarily in the left Sylvian fissure, computed tomography angiography (CTA) performed immediately after CT did not reveal any obvious vascular abnormalities such as an intracranial aneurysm. An emergency cesarean section was performed, and a healthy infant was delivered. Cerebral digital subtraction angiography (DSA) was performed the day following surgery, which revealed a saccular aneurysm measuring 4.3 mm × 2.4 mm in the left middle cerebral artery. Left craniotomy and clipping of the aneurysm were performed. The clot around the aneurysm was relatively solid. This case report is of significance given that initial CTA was negative for SAH during pregnancy, suggesting the requirement for immediate DSA or another CTA in such cases. There are many previous reports on false-negative CTA findings or disappearance and reappearance of aneurysms in SAH patients, and various biophysical and dynamic parameters are suggested to cause such phenomena. However, there are no reports on similar occurrences during pregnancy. Although the precise cause remains unclear, multiple factors associated with homeostasis during pregnancy were possibly associated with the transient disappearance in this patient. PMID:25732356

  15. Clinical usefulness of positron emission tomography in the evaluation of regional cerebral blood flow and cerebral oxygen metabolism under glycerol and carbon dioxide loadings

    Energy Technology Data Exchange (ETDEWEB)

    Tanada, Shuji; Yonekura, Yoshiharu; Senda, Michio

    1987-02-01

    Cerebral blood flow (CBF) and oxygen metabolism (CMRO/sub 2/) were studied in normal cerebral cortices by positron emission tomography using continuous inhalation method of oxygen-15 labeled carbon dioxide and oxygen, and single inhalation method of oxygen-15 labeled carbon monoxide. The values of CBF, CMRO/sub 2/, and oxygen extraction fraction (OEF) in cerebral cortices of 18 healthy normal volunteers represented 40 +- 7 ml/100 ml/min, 3.2 +- 0.5 ml O/sub 2//100 ml/min, and 0.43 +- 0.07, respectively. In cases with glycerol loading, CBF increased in 10/14 cases. Studies of 6 cases with intracranial pressure indicated the presence of mechanism by which depressed CMRO/sub 2/ improved and was kept in normal values. The loading of 5% carbon dioxide showed an increase in CBF in cases with cerebral infarction, which implied the good cerebral vascular response to the elevated arterial carbon dioxide, but no particular changes were observed in CMRO/sub 2/ which seemed to be less responsive to the elevated arterial carbon dioxide level. In cases with moyamoya disease, 5% carbon dioxide loading showed no changes in CBF and CMRO/sub 2/. This suggested the poor cerebral vascular response to the elevation of arterial carbon dioxide, while X-ray CT failed to demonstrate any abnormalities in corresponding areas. Positron emission tomography proved to have a great potentiality regarding the evaluation of the changes in cerebral blood flow and cerebral oxygen metabolism under various loadings.

  16. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  17. Central nervous system involvement in systemic lupus erythematosus. The application of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S.; Ishigatsubo, Y.; Katou, K.; Sakamoto, H.; Chiba, J. (Yokohama City Univ. (Japan). Faculty of Medicine)

    1982-06-01

    Cranial computed tomography scans were performed on 47 patients with systemic lupus erythematosus (SLE). Abnormal findings in the computed tomograms (CT) were observed in 17 patients (36.2%). Cerebral atrophy was the most common feature (eight cases), followed by abnormal high density areas (five cases), abnormal low density areas (three cases), sulcal enlargement (two cases), intracranial hemorrhage (one case) and others (two cases). The abnormal cranial CT group of SLE was associated with a significantly higher incidence of urinary casts and of thrombocytopenia. In particular, the frequency of urinary casts was greater in the group with cerebral atrophy than in the group with normal CT findings, and there was a higher incidence of alopecia, leukopenia and thrombocytopenia in the group with intracranial calcifications. Neuropsychiatric involvements were noted in 70.6% of patients with CT abnormalities, but neuropsychiatric features (20.7%) and electroencephalographic abnormalities (44.8%) were also observed in patients with normal CT findings. The age at onset of SLE, the mean duration of the disease and the survival rate were not significantly different between the groups with and without CT abnormalities, but the mortality rate was significantly greater in the group with CT abnormalities, especially among those with brain atrophy. Concerning the relationship between the findings of cranial CT and corticosteroid treatment, there was no significant difference in either the total dose or the mean duration of prednisolone therapy. Although SLE patients with cerebral atrophy were taking a larger maintenance dose of corticosteroids, the differences were not statistically significant.

  18. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  19. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  20. Regional Cerebral Glucose Metabolism in Novelty Seeking and Antisocial Personality: A Positron Emission Tomography Study

    Science.gov (United States)

    Park, So Hyeon; Park, Hyun Soo

    2016-01-01

    Novelty seeking (NS) and antisocial personality (ASP) are commonly exhibited by those who suffer from addictions, such as substance abuse. NS has been suggested to be a fundamental aspect of ASP. To investigate the neurobiological substrate of NS and ASP, we tested the relationship between regional cerebral glucose metabolism and the level of NS, determining the differences between individuals with and without ASP. Seventy-two healthy adults (43 males, mean age±SD=38.8±16.6 years, range=20~70 years; 29 females, 44.2±20.1 years, range=19~72 years) underwent resting-state brain positron emission tomography (PET) 40 minutes after 18F-fluorodeoxyglucose (FDG) injection. Within 10 days of the FDG PET study, participants completed Cloninger's 240-item Temperament and Character Inventory (TCI) to determine NS scores. Participants with and without ASP were grouped according to their TCI profiles. Statistical parametric mapping analysis was performed using the FDG PET and TCI profile data. NS scores positively correlated with metabolism in the left anterior cingulate gyrus and the insula on both sides of the brain and negatively correlated with metabolism in the right pallidum and putamen. Participants with ASP showed differences in cerebral glucose metabolism across various cortical and subcortical regions, mainly in the frontal and prefrontal areas. These data demonstrate altered regional cerebral glucose metabolism in individuals with NS and ASP and inform our understanding of the neurobiological substrates of problematic behaviors and personality disorders. PMID:27574485

  1. A computed tomography study of myotonic dystrophy

    International Nuclear Information System (INIS)

    Mental symptom is one of the characteristic features in myotonic dystophy, but documentation of mental signs including pathological changes of the brain has been imprecise. An attempt to show the involvement of the central nervous system by CT scan and EEG has been done in our department. The material consists of 14 patients 10 males and 4 females, from 15 to 50 years of age. CT scan of the 14 patients showed diffuse enlargement of lateral and third ventricles without definite atrophy of cerebral cortex and brainstem. Measurements of various parts of the ventricles showed a difference and an increase with age of values compared with that obtained from 49 neurologically normal persons (P0.05). Our study reveals that the ventricular enlargement is more correlated with aging than the severity of muscle involvement or the degree of mental deterioration. This fact possibly reflects a progressive nature of the pathology of the brain, especially the white matter. (author)

  2. Computed tomography of the thorax in children with cystic fibrosis

    International Nuclear Information System (INIS)

    We studied retrospectively the value of computed tomography of the thorax in patients suffering from cystic fibrosis. Twenty-six patients were studied, which showed as the most frequency pulmonary findings bronchial wall thickening in 22 patients (84.6), followed by bronchiectasis in 16 patients (61.5%). Less frequent finding were ill-defined patch consolidation, mucoid impaction, bullaes and atelectasis. We found a predominant distribution of bronchial wall thickening and bronchiectasis in the upper lobes of the lungs. Computed tomography is the more sensitive technique for early visualization and location of the manifestations of cystic fibrosis bronchopathy. (author)

  3. A controlled study of positron-emission-tomography and positron-emission-tomography/computed tomography in differential diagnosis of solitary pulmonary nodules-report of 60 cases

    Institute of Scientific and Technical Information of China (English)

    DING Qi-yong; HUA Yan-qing; ZHANG Guo-zhen; ZHAO Jun; GUAN Yi-hui; GE Xiao-jun; MAO Ding-biao; ZUO Chuan-tao

    2005-01-01

    @@ The differential diagnosis of solitary pulmonary nodules (SPNs) remains a challenge. It is acknowledged that combining positron-emission tomography (PET) and computed tomography (CT) offers the most reliable noninvasive method for the diagnosis of SPNs.

  4. Missing wedge computed tomography by iterative algorithm DIRECTT.

    Science.gov (United States)

    Kupsch, Andreas; Lange, Axel; Hentschel, Manfred P; Lück, Sebastian; Schmidt, Volker; Grothausmann, Roman; Hilger, André; Manke, Ingo

    2015-01-01

    A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and neutron tomography under restricted geometric boundary conditions. We investigate the performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted kernel density estimation, which yields the probabilities of boundary orientations. The DIRECTT results are assessed at different signal-to-noise ratios by means of local and integral evaluation parameters. PMID:26367127

  5. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  6. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  7. Detection of hepatic tumor by means of single photon emission computed tomography, Gray scale ultrasonography, and computed tomography

    International Nuclear Information System (INIS)

    We have studied the hepatic tumor detection by single photon emission computed tomography (SPECT) using rotatory chair and gamma camera. SPECT were taken by multiple section slice not only in transaxial view, but also in frontal and sagital. The results were superior in detectability to conventional liver scintiphoto (CLS). In cases of obstructive jaundice, ultrasonography (US) and/or computed axial tomography (CAT) should be taken before SPECT, because there are various probabilities of evaluation like as false positive by means of SPECT. Simultaneous interpretation of SPECT, US, and CAT was more helpful than independent interpretation

  8. Computed tomography of cystic pancreatic fibrosis

    International Nuclear Information System (INIS)

    The computer tomographic appearances of atrophic and lipomatous degeneration of the pancreas in cystic pancreatic fibrosis are described. CT exploration of the pancreas in recommended, particularly in differential diagnostic aspects of cystic fibrosis. (orig.)

  9. Emission Computed Tomography: A New Technique for the Quantitative Physiologic Study of Brain and Heart in Vivo

    Science.gov (United States)

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Schelbert, H. R.; Kuhl, D. E.

    1978-01-01

    Emission computed tomography can provide a quantitative in vivo measurement of regional tissue radionuclide tracer concentrations. This facility when combined with physiologic models and radioactively labeled physiologic tracers that behave in a predictable manner allow measurement of a wide variety of physiologic variables. This integrated technique has been referred to as Physiologic Tomography (PT). PT requires labeled compounds which trace physiologic processes in a known and predictable manner, and physiologic models which are appropriately formulated and validated to derive physiologic variables from ECT data. In order to effectively achieve this goal, PT requires an ECT system that is capable of performing truly quantitative or analytical measurements of tissue tracer concentrations and which has been well characterized in terms of spatial resolution, sensitivity and signal to noise ratios in the tomographic image. This paper illustrates the capabilities of emission computed tomography and provides examples of physiologic tomography for the regional measurement of cerebral and myocardial metabolic rate for glucose, regional measurement of cerebral blood volume, gated cardiac blood pools and capillary perfusion in brain and heart. Studies on patients with stroke and myocardial ischemia are also presented.

  10. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren;

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  11. Micro-computed tomography: an alternative method for shark ageing.

    Science.gov (United States)

    Geraghty, P T; Jones, A S; Stewart, J; Macbeth, W G

    2012-04-01

    Micro-computed tomography (microCT) produced 3D reconstructions of shark Carcharhinus brevipinna vertebrae that could be virtually sectioned along any desired plane, and upon which growth bands were readily visible. When compared to manual sectioning, it proved to be a valid and repeatable means of ageing and offers several distinct advantages over other ageing methods. PMID:22497384

  12. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  13. Multidetector computed tomography of jaw lesions in children and adolescents

    International Nuclear Information System (INIS)

    Full text: Jaw lesions in paediatric and adolescent population are uncommon and can arise in odontogenic or non-odontogenic tissues. With the advent of multidetector computed tomography (MDCT), algorithm for imaging jaw lesions has changed dramatically. This pictorial essay describes the imaging appearance of commonly encountered jaw lesions in children and adolescents with emphasis on MDCT findings

  14. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H;

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary ...

  15. Computed Tomography Features of Spontaneously Perforated Pyometra: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.S.; Tan, C.K.; Mak, C.W.; Chia, C.C.; Kuo, C.Y.; Yu, W.L. [Chi-Mei Medical Center, Tainan, Taiwan (China). Depts. of Intensive Care Medicine, Radiology, Obstetrics and Gynecology, and Surgery

    2006-03-15

    Spontaneous perforation of pyometra is an extremely rare emergent gynecologic disease. We report a 73-year-old woman with a spontaneously perforated pyometra presenting with acute abdomen in the emergency department. A dedicated computed tomography examination of the abdominal and pelvic regions revealed the diagnosis. The patient recovered well after surgical intervention and antibiotic treatment.

  16. Computed tomography of the human developing anterior skull base

    NARCIS (Netherlands)

    J. van Loosen (J.); A.I.J. Klooswijk (A. I J); D. van Velzen (D.); C.D.A. Verwoerd (Carel)

    1990-01-01

    markdownabstractAbstract The ossification of the anterior skull base, especially the lamina cribrosa, has been studied by computed tomography and histopathology. Sixteen human fetuses, (referred to our laboratory for pathological examination after spontaneous abortion between 18 and 32 weeks of ge

  17. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  18. An Easily Assembled Laboratory Exercise in Computed Tomography

    Science.gov (United States)

    Mylott, Elliot; Klepetka, Ryan; Dunlap, Justin C.; Widenhorn, Ralf

    2011-01-01

    In this paper, we present a laboratory activity in computed tomography (CT) primarily composed of a photogate and a rotary motion sensor that can be assembled quickly and partially automates data collection and analysis. We use an enclosure made with a light filter that is largely opaque in the visible spectrum but mostly transparent to the near…

  19. RADIAL COMPUTED TOMOGRAPHY OF AIR CONTAMINANTS USING OPTICAL REMOTE SENSING

    Science.gov (United States)

    The paper describes the application of an optical remote-sensing (ORS) system to map air contaminants and locate fugitive emissions. Many ORD systems may utilize radial non-overlapping beam geometry and a computed tomography (CT) algorithm to map the concentrations in a plane. In...

  20. Computed Tomography-Enhanced Anatomy Course Using Enterprise Visualization

    Science.gov (United States)

    May, Hila; Cohen, Haim; Medlej, Bahaa; Kornreich, Liora; Peled, Nathan; Hershkovitz, Israel

    2013-01-01

    Rapid changes in medical knowledge are forcing continuous adaptation of the basic science courses in medical schools. This article discusses a three-year experience developing a new Computed Tomography (CT)-based anatomy curriculum at the Sackler School of Medicine, Tel Aviv University, including describing the motivations and reasoning for the…

  1. Computed tomography in the diagnosis of the lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Iwakura, Yuichiro (Yatsushiro General Hospital, Kumamoto (Japan)); Hayashi, Yasuo; Suzuki, Mutsuaki; Uemura, Mitsuharu; Fukuda, Kazuyuki; Koito, Hirofumi

    1984-06-01

    In this study, effectiveness of computed tomography (CT) in diagnosing lumbar disc herniation was evaluated. Twenty CT examinations which were interpreted as positive for a herniated disc, and were comfirmed by myelography, were reviewed. In 19 patients, CT demonstrated posterior protrusion of the disc but in one normal disc. Three typical cases were described. This study suggests that CT accurately demonstrates lumbar disc herniation.

  2. The role of computed tomography in modern paediatric uroradiology

    International Nuclear Information System (INIS)

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study

  3. Improvement of reconstructed image quality of neutron computed tomography

    International Nuclear Information System (INIS)

    Neutron computed tomography has been studied. Endeavor has been given to obtain high image quality of CT reconstruction. Film method is comparatively preferred to dynamic neutron TV one. Some models for nuclear fuels have been reconstructed. Dispersion of 300 μm Eu-particles in TiO2 pellets, which simulate PuO2/UO2 nuclear fuel, have been reconstructed

  4. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo;

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...

  5. Bone densitometry in healthy cats by quantitative computed tomography

    International Nuclear Information System (INIS)

    The radiodensity of the trabecular bone of the lumbar vertebrae in 16 healthy adult cats was studied using quantitative computed tomography (QCT). The average radiodensity of the trabecular bone of the second lumbar vertebra was 436.1 +- 42.1 Hounsfield units. However, there was a nonhomogeneous radiodensity distribution of the vertebral body. (author)

  6. Coronary computed tomography - present status and future directions

    NARCIS (Netherlands)

    Apfaltrer, P.; Schoepf, U. J.; Vliegenthart, R.; Rowe, G. W.; Spears, J. R.; Fink, C.; Nance, J. W.

    2011-01-01

    The use of coronary computed tomography angiography (cCTA) is growing rapidly, in large part because of fast-paced technical innovations that have increased diagnostic accuracy while providing new opportunities for radiation dose reduction. cCTA using recent generation CT scanners has been repeatedl

  7. COMPUTED TOMOGRAPHY IN HYDATID CYST OF THE ORBIT

    Directory of Open Access Journals (Sweden)

    K. Abbassioun

    1982-07-01

    Full Text Available Two cases of hydatid cysts of the orbit causing unilateral exophthalmos are reported. Diagnosis were suspected by means of computed tomography (CT and confirmed at Operation. CT changes are described and its value in diagnosis of this lesion particularly in the endemic areas is stressed.

  8. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  9. Tolerance Verification of an Industrial Assembly using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo; Regi, Francesco

    2016-01-01

    This paper reports on results of tolerance verification of a multi-material assembly by using Computed Tomography (CT). The workpiece comprises three parts which are made out of different materials. Five different measurands were inspected. The calculation of measurement uncertainties was attempt...

  10. Computed tomography of the gastro-intestinal tract : its value

    International Nuclear Information System (INIS)

    The subject discussed include indications and accuracy of CT - computed tomography, technical considerations, common pitfalls in CT interpretation, parameters for CT evaluation, benign lesions, double halo and target signs, hyperattenuated, inflammatory bowel disease, intestinal ischaemia, primary adenocarcinoma of the GIT, lymphoma and leiomyosarcoma (3 refs.)

  11. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    NARCIS (Netherlands)

    F.A.A. Mohamed Hoesein (Firdaus); P.A. de Jong (Pim); J.W.J. Lammers; W.P. Mali (Willem); M. Schmidt (Michael); H.J. de Koning (Harry); C.M. van der Aalst (Carlijn); M. Oudkerk (Matthijs); R. Vliegenthart (Rozemarijn); B.T.J. van Ginneken (Berbke); E.M. van Rikxoort (Eva); P. Zanen (Pieter)

    2013-01-01

    textabstractBackground:There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping acco

  12. Computed tomography structural lung changes in discordant airflow obstruction

    NARCIS (Netherlands)

    Hoesein, F.A.A.M.; Jong, P.A. de; Lammers, J.W.; Mali, W.P.Th.; Schmidt, M.; Koning, H.J. de; Aalst, C. van der; Oudkerk, M.; Vliegenthart, R.; Ginneken, B. van; Rikxoort, E.M. van; Zanen, P.

    2013-01-01

    Background: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to cl

  13. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    OpenAIRE

    Firdaus A A Mohamed Hoesein; de Jong, Pim A; Lammers, Jan-Willem J; Willem Pthm Mali; Michael Schmidt; de Koning, Harry J.; Carlijn van der Aalst; Matthijs Oudkerk; Rozemarijn Vliegenthart; Bram van Ginneken; van Rikxoort, Eva M; Pieter Zanen

    2013-01-01

    BACKGROUND: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC 70%; group 2LLN; and group 370% but FEV1

  14. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Jakobsen, Annika Loft; Hansen, Mads;

    2006-01-01

    In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study was to investigate the value of...

  15. Correction of polychromatic radiogram errors in computer tomography images

    International Nuclear Information System (INIS)

    The polychromatic errors in radiograms obtained by computer tomography are corrected by an image processing facility with e.g. image storage equipment. In the computer tomogram itself no correction of the original projection data is performed. From it there is derived an error image and subtracted from the original image in order to get a corrected image. This is done by assessing the projected data of the biological tissues and calculating therefrom error-projection data by means of mathematical methods. (RW)

  16. Multi-scale analysis of lung computed tomography images

    OpenAIRE

    Gori, I.; Bagagli, F.; Fantacci, M. E.; Martinez, A. Preite; Retico, A.; De Mitri, I.; Donadio, S.; Fulcheri, C.; Gargano, G; Magro, R.; Santoro, M; Stumbo, S

    2009-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on...

  17. Computed tomography of the temporal horns at Alzheimer's disease

    International Nuclear Information System (INIS)

    In the literature there are different opinions referring to the involvement of the temporal lobes or horns at Alzheimer's disease. Conventionally computed tomogram of the head does not include the temporal horn in its full length. A simple method to demonstrate the temporal horns after cranial computer tomography is described. It allows the evaluation of temporal lobe and temporal horn if questionable alterations at Alzheimer's disease are to be discussed. (orig.)

  18. A case of cerebral cysticercosis detected by computed tomography

    International Nuclear Information System (INIS)

    Cysticercosis is well known as a parasitic infection that commonly affects the central nervous system. A 60-year-old man, who once lived in the mainland of China in the 1940s, was admitted to the hospital complaining of the right motor weakness and speech disturbance. Neurological examinations revealed the right hemiparesis with increase of deep tendon reflexes and motor dysphasia. The skull x-ray films showed no abnormal finding, but many small fusiform calcifications were found in the x-ray films of soft tissues of the limbs. Brain CT demonstrated several small rounded and calcified high density areas and cystic low density areas in the parenchyma with a marked dilatation of the ventricular system. And a large cystic mass of the left fronto-parietal region compressed the body of the left lateral ventricle. After infusion of contrast medium, a small ring-enhanced density area in the frontal region was revealed. By a craniotomy, the large cyst, which had a bluish transparent wall, was totally extirpated. The nature of the cystic content was similar to that of the cerebro-spinal fluid. On histological examination of the cyst wall any scolex was not found, but papillary folds and typical three layers of cysticercosis were observed. The immunological testing for cysticercosis was positive on the serum of the patient. These findings confirmed the diagnosis of human cysticercosis. Wider applications of CT in clinical practice could discover more cases of cysticercosis in the recent situation of world wide communication of population. This report will be the first one of cysticercosis which mainly discussed about the findings of CT in the Japanese literature. (author)

  19. Case of cerebral cysticercosis detected by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomosugi, Tetsuzo; Gondo, Masazumi; Kanamaru, Reizo; Asakura, Tetsuhiko; Mihara, Tadahiro (Kagoshima Univ. (Japan). Faculty of Medicine)

    1983-03-01

    Cysticercosis is well known as a parasitic infection that commonly affects the central nervous system. A 60-year-old man, who once lived in the mainland of China in the 1940s, was admitted to the hospital complaining of the right motor weakness and speech disturbance. Neurological examinations revealed the right hemiparesis with increase of deep tendon reflexes and motor dysphasia. The skull x-ray films showed no abnormal finding, but many small fusiform calcifications were found in the x-ray films of soft tissues of the limbs. Brain CT demonstrated several small rounded and calcified high density areas and cystic low density areas in the parenchyma with a marked dilatation of the ventricular system. And a large cystic mass of the left fronto-parietal region compressed the body of the left lateral ventricle. After infusion of contrast medium, a small ring-enhanced density area in the frontal region was revealed. By a craniotomy, the large cyst, which had a bluish transparent wall, was totally extirpated. The nature of the cystic content was similar to that of the cerebro-spinal fluid. On histological examination of the cyst wall any scolex was not found, but papillary folds and typical three layers of cysticercosis were observed. The immunological testing for cysticercosis was positive on the serum of the patient. These findings confirmed the diagnosis of human cysticercosis. Wider applications of CT in clinical practice could discover more cases of cysticercosis in the recent situation of world wide communication of population. This report will be the first one of cysticercosis which mainly discussed about the findings of CT in the Japanese literature.

  20. Global seismic tomography and modern parallel computers

    Directory of Open Access Journals (Sweden)

    A. Piersanti

    2006-06-01

    Full Text Available A fast technological progress is providing seismic tomographers with computers of rapidly increasing speed and RAM, that are not always properly taken advantage of. Large computers with both shared-memory and distributedmemory architectures have made it possible to approach the tomographic inverse problem more accurately. For example, resolution can be quantified from the resolution matrix rather than checkerboard tests; the covariance matrix can be calculated to evaluate the propagation of errors from data to model parameters; the L-curve method can be applied to determine a range of acceptable regularization schemes. We show how these exercises can be implemented efficiently on different hardware architectures.

  1. Single-photon emission computed tomography/computed tomography in abdominal diseases.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Danieli, Roberta; Simonetti, Giovanni

    2007-01-01

    Single-photon emission computed tomography (SPECT) studies of the abdominal region are established in conventional nuclear medicine because of their easy and large availability, even in the most peripheral hospitals. It is well known that SPECT imaging demonstrates function, rather than anatomy. It is useful in the diagnosis of various disorders because of its ability to detect changes caused by disease before identifiable anatomic correlates and clinical manifestations exist. However, SPECT data frequently need anatomic landmarks to precisely depict the site of a focus of abnormal tracer uptake and the structures containing normal activity; the fusion with morphological studies can furnish an anatomical map to scintigraphic findings. In the past, software-based fusion of independently performed SPECT and CT or magnetic resonance images have been demonstrated to be time consuming and not useful for routine clinical employment. The recent development of dual-modality integrated imaging systems, which provide SPECT and CT images in the same scanning session, with the acquired images co-registered by means of the hardware, has created a new scenario. The first data have been mainly reported in oncology patients and indicate that SPECT/CT is very useful because it is able to provide further information of clinical value in several cases. In SPECT studies of abdominal diseases, hybrid SPECT/CT can play a role in the differential diagnosis of hepatic hemangiomas located near vascular structures, in precisely detecting and localizing active splenic tissue caused by splenosis in splenectomy patients, in providing important information for therapy optimization in patients submitted to hepatic arterial perfusion scintigraphy, in accurately identifying the involved bowel segments in patients with inflammatory bowel diseases, and in correctly localizing the bleeding sites in patients with gastrointestinal bleeding. PMID:17161039

  2. Cranial computed tomography in infancy and childhood

    International Nuclear Information System (INIS)

    A large number of pediatric cases have been accumulated and categorized according to congenital abnormalities, trauma, hydrocephalus, tumors, and infection. Each category contains background material accompanied by computed-tomographic (CT) illustrations and a related discussion. The material is derived from 6,000 CT scans performed at Children's Hospital National Medical Center in Washington, DC since 1973

  3. Estimation of lung growth using computed tomography

    NARCIS (Netherlands)

    P.A. de Jong (Pim); Y. Nakano (Yasutaka); M.H. Lequin (Maarten); P.J.F.M. Merkus (Peter); H.A.W.M. Tiddens (Harm); J.C. Hogg; H.O. Coxson (Harvey)

    2003-01-01

    textabstractAnatomical studies suggest that normal lungs grow by rapid alveolar addition until about 2 yrs of age followed by a gradual increase in alveolar dimensions. The aim of this study was to examine the hypothesis that normal lung growth can be monitored by computed tomograp

  4. Mycosis fungoides: manifestations on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shapeero, L.G.; Young, S.W.

    1983-07-01

    Mtcosis fungoides is a malignant lymphoma of the skin that causes intense erythema, plaques, edema, and induration. The primary computed tomographic findings of mycosis fungoides, i.e., skin thickening, tumorous infiltration, edema of the soft tissues, and lymphadenopathy, are presented in two patients.

  5. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  6. Regional cerebral glucose metabolic rate in human sleep assessed by positron emission tomography

    International Nuclear Information System (INIS)

    The cerebral metabolic rate of glucose was measured during nighttime sleep in 36 normal volunteers using positron emission tomography and fluorine-18-labeled 2-deoxyglucose (FDG). In comparison to waking controls, subjects given FDG during non-rapid eye movement (NREM) sleep showed about a 23% reduction in metabolic rate across the entire brain. This decrease was greater for the frontal than temporal or occipital lobes, and greater for basal ganglia and thalamus than cortex. Subjects in rapid eye movement (REM) sleep tended to have higher cortical metabolic rates than walking subjects. The cingulate gyrus was the only cortical structure to show a significant increase in glucose metabolic rate in REM sleep in comparison to waking. The basal ganglia were relatively more active on the right in REM sleep and symmetrical in NREM sleep

  7. Regional cerebral glucose metabolic rate in human sleep assessed by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buchsbaum, M.S.; Wu, J.; Hazlett, E.; Sicotte, N.; Bunney, W.E. Jr. (Univ. of California, Irvine (USA)); Gillin, J.C. (Univ. of California, San Diego (USA))

    1989-01-01

    The cerebral metabolic rate of glucose was measured during nighttime sleep in 36 normal volunteers using positron emission tomography and fluorine-18-labeled 2-deoxyglucose (FDG). In comparison to waking controls, subjects given FDG during non-rapid eye movement (NREM) sleep showed about a 23% reduction in metabolic rate across the entire brain. This decrease was greater for the frontal than temporal or occipital lobes, and greater for basal ganglia and thalamus than cortex. Subjects in rapid eye movement (REM) sleep tended to have higher cortical metabolic rates than walking subjects. The cingulate gyrus was the only cortical structure to show a significant increase in glucose metabolic rate in REM sleep in comparison to waking. The basal ganglia were relatively more active on the right in REM sleep and symmetrical in NREM sleep.

  8. Computer tomography of large dust clouds in complex plasmas

    International Nuclear Information System (INIS)

    The dust density is a central parameter of a dusty plasma. Here, a tomography setup for the determination of the three-dimensionally resolved density distribution of spatially extended dust clouds is presented. The dust clouds consist of micron-sized particles confined in a radio frequency argon plasma, where they fill almost the entire discharge volume. First, a line-of-sight integrated dust density is obtained from extinction measurements, where the incident light from an LED panel is scattered and absorbed by the dust. Performing these extinction measurements from many different angles allows the reconstruction of the 3D dust density distribution, analogous to a computer tomography in medical applications

  9. Optical coherence tomography reveals in vivo cortical structures of adult rats in response to cerebral ischemia injury

    Science.gov (United States)

    Ni, Yi-rong; Guo, Zhou-yi; Shu, So-yun; Bao, Xin-min

    2008-12-01

    Optical coherence tomography(OCT) is a high resolution imaging technique which uses light to directly image living tissue. we investigate the potential use of OCT for structural imaging of the ischemia injury mammalian cerebral cortex. And we examine models of middle cerebral artery occlusion (MCAO) in rats in vivo using OCT. In particular, we show that OCT can perform in vivo detection of cortex and differentiate normal and abnormal cortical anatomy. This OCT system in this study provided an axial resolution of 10~15μ m, the transverse resolution of the system is about 25 μm. OCT can provide cross-sectional images of cortical of adult rats in response to cerebral ischemia injury.We conclude that OCT represents an exciting new approach to visualize, in real-time, pathological changes in the cerebral cortex structures and may offer a new tool for Possible neuroscience clinical applications.

  10. Flip-flop phenomenon in systemic sclerosis on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Systemic sclerosis (SSc) is a rare autoimmune disease, which may affect multiple organ systems. Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) can demonstrate the degree and anatomical extent of involvement in the entire body and coexisting malignancies in connective tissue diseases. We present a case of SSc with an increased 18F-FDG uptake in the cutaneous and subcutaneous tissues even higher than the neighboring skeletal muscles (“flip-flop phenomenon,” that is, an increased 18F-FDG uptake in the skin but a decreased 18F-FDG uptake in the skeletal muscles)

  11. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  12. Measurement of cerebral blood flow rate and its relationship with brain function using optical coherence tomography

    Science.gov (United States)

    Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe

    2016-03-01

    Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.

  13. X-ray computed tomography of PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Pfrang, Andreas; Veyret, Damien; Tsotridis, Georgios [Commission of the European Communities, Petten (Netherlands). Joint Reseach Centre, Inst. for Energy; Janssen, Gaby [Energy Research Centre of the Netherlands ECN, Petten (Netherlands). Dept. of Hydrogen and Clean Fossil Fuels

    2010-07-01

    Proton exchange membrane (PEM) fuel cells were investigated by 3D x-ray computed tomography at a voxel size of 0.7 {mu}m. It is shown that this lab-based technique is not only suitable for the investigation of gas diffusion layers (GDL) as well as the investigation of membrane electrode assemblies (MEA), but also allows the calculation of macroscopic physical properties. The resolution of computed tomography is clearly sufficient to image the carbon fiber structure of gas diffusion layers in the as received GDLs as well as GDLs integrated into membrane electrode assemblies. It is also possible to visualize the catalyst layer within the MEA, which allows the investigation of layer thickness and structural defects on a larger scale than with conventional techniques. The macroscopic effective thermal conductivities of the gas diffusion layers were computed based on the 3D GDL structure reconstructed from tomography data to produce more reliable input data for fuel cell modeling. The computation was carried out by solving the energy equation considering a pure thermal conduction problem. The computations show - in agreement with the expectation and experimental data - that the through-plane thermal conductivities are lower than the in-plane thermal conductivities. (orig.)

  14. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  15. Comparison of computed tomography and conventional tomography of tumors located in the nasopharynx and paranasal sinuses

    International Nuclear Information System (INIS)

    The value of conventional tomography for the clinical evaluation of tumors located in the nasopharynx and paranasal sinuses has been well established. The present study analyzed the potential improvement of the preoperative evaluation of the extent of those tumors by computed tomography. Conventional tomography was performed with polycycloidal movement. An initial comparison was made using a normal skull phantom. This facilitated the comparison of both diagnostic methods for the recognition of osseous structures. The evaluation of the clinical efficiency of both diagnostic modalities was performed with various cases of early and late tumors involving bony and soft tissue structures of the skull. The correlation of the information obtained by the radiographic methods with the extent of the tumor seen at the operation were the final criteria. Follow-up examinations after radiotherapy wereemployed in several cases. The results and implications of this study are presented. (orig.) 891 MG/orig. 892 MB

  16. Coordinate Metrology by Traceable Computed Tomography

    OpenAIRE

    Müller, Pavel; De Chiffre, Leonardo; Hansen, Hans Nørgaard; Cantatore, Angela

    2013-01-01

    Røntgen computer tomografi (CT) er en måleteknik som er blevet en vigtig teknologi i produktionsmiljøer gennem de seneste år. På grund af et antal fordele ved CT, eksempelvis sammenlignet med koordinatmålemaskiner (CMM’er), er CT på det seneste blevet udbredt indenfor produktions- og koordinatmåleteknik og er aktuelt ved at blive en mere og mere vigtig måleteknik til dimensionsmålinger. Dette er primært på grund af at man med CT relativt hurtigt kan visualisere en komplet tredimensionel model...

  17. Computed tomography in congenital ocular motor apraxia

    Energy Technology Data Exchange (ETDEWEB)

    Eda, I.; Takashima, S.; Kitahara, T.; Ohno, K.; Takeshita, K.

    1984-09-01

    Unusual computed tomographic findings were observed in four patients with congenital ocular motor apraxia (COMA). These (CT) findings were characteristic in the posterior cranial fossa, with a dilated or deformed shape and size of the fourth ventricle, particularly its upper portion. One case revealed partial agenesis of the cerebellar vermis. It was suggested that the four patients subjected to CT showed abnormal topography of the cerebellar vermis or the brain stem. We postulate that these CT findings in COMA may have an important role in its pathogenesis.

  18. Computed tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Burmester, E.; Gmelin, E.; Mendoza, A.S.

    1985-12-01

    An essential pre-condition for the interpretation of computer tomographs of the elbow joint is a knowledge of the normal anatomy. The complexity of the joint requires a definite protocol for the examination, since only in this way it is possible to distinguish all anatomical structures and pathological processes. A clinical example is used to show that CT of the elbow joint is superior to all other radiographic methods for demonstrating osteochondritis dissecans. It is therefore an important additional method for demonstrating the elbow joint.

  19. Intramammary incidental findings on staging computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey, E-mail: alex.surow@medizin.uni-halle.de [Department of Radiology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Fiedler, Eckhard [Department of Dermatology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Wienke, Andreas [Department of Medical Statistics, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Holzhausen, Hans-Jürgen [Department of Pathology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany); Spielmann, Rolf-Peter; Behrmann, Curd [Department of Radiology, Martin-Luther-University Halle-Wittenberg, Ernst-Grubestr. 40, 06097 Halle (Germany)

    2012-09-15

    Purpose: Incidental findings are a common feature in computer tomographic examinations of the chest. Breast incidentalomas, however, were described only sporadically. The purpose of this study was to evaluate retrospectively incidental breast findings and to compare radiological features of benign and malignant breast lesions. Materials and methods: From January 2006 to December 2010 a total of 8105 computer tomographic examinations were performed at our institution. In 89 patients incidental breast lesions were diagnosed. 64 of the identified patients were referred for further clinical, radiological, and hystopathological examination. All patients were female with a median age of 62 years, range 39–82 years. Results: A total of 98 breast lesions were identified in the 64 patients. The mean size was 12.0 ± 8.0 mm. Primary breast carcinoma was identified in 9, breast metastases in 27, and benign findings in 28 patients. Malignant lesions demonstrated more often marked enhancement and showed a higher density compared with benign lesions. Benign findings were more often lobular in shape and had spiculated margins. Most of the breast metastases were round or oval in shape with circumscribed margins and marked homogenous enhancement. There was no significant difference between the breast cancer and benign findings groups in the characteristics of the lesions. Conclusion: The breast is a very important region and should be carefully evaluate on chest CT. There are no certain radiological criteria to differentiate between malignant and benign breast lesions on CT. Therefore all breast incidentalomas should be evaluated by further radiological/histological investigations.

  20. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended...

  1. Intracranial calcification on paediatric computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, B.; Cavanagh, N.

    1986-07-01

    An analysis of the computed tomograms of 18000 children examined consecutively form the basis of an assessment of the diagnostic significance of intracranial calcification. The low incidence of physiological calcification in the pineal and choroid of about 2% up to the age of 8 years, but increasing 5-fold by the age of 15 years, is confirmed. Pathological calcification occurred in 1.6%, the commonest causes being neoplasms (43%), neuroectodermal syndromes (20%) and infections (12%). Diffuse basal ganglia calcification (15%) bore little relation to the diverse clinical symptomatology, and routine biochemical studies showed a disorder of metabolism to be present in only 6 cases. Calcification has not been previously noted in acute haemorrhagic leukoencephalitis, Pertussis or Cocksackie encephalitis, infantile neuraxonal dystrophy, Marinesco-Sjoegren syndrome or in the basal ganglia in neurofibromatosis.

  2. Computed tomography in staging of oesophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Salonen, O.; Kivisaari, L.; Standertskjoeld-Nordenstam, C.G.; Somer, K.; Virkkunen, P.

    1987-01-01

    The computed tomographic (CT) findings in 45 patients with histologically proved oesophageal carcinoma are reviewed. In 20 of these patients the CT findings were correlated with findings at surgery (19 patients) or autopsy (1 patient). Correlation analysis showed that the accuracy of CT in assessing both invasion of adjacent organs and mediastinal and abdominal lymph node involvement is limited. 25 patients were considered inoperable. In 15 of these conclusion was based on CT findings of distant metastases (14 patients) or definite local invasion (1 patient). 10 patients were inoperable for other reasons (general health condition). The value of CT was found to be in detecting distant metastases, thus avoiding unnecessary radical surgery. It is not a reliable way of defining the primary tumour.

  3. Significance of triplane computed tomography in otolaryngology

    International Nuclear Information System (INIS)

    The authors obtained direct sagittal CT scans of the head using a new method for positioning the head of patient in sitting position. Direct sagittal scans are more useful than computed rearranged scans in a better spatial and density resolution. The triplane CT (axial, coronal, and sagittal CT) greatly improves three dimentional recognition of the intracranial and facial structures and the extent of the lesion. A series of patients with various nasal and oropharyngeal tumors was examined with the triplane CT. The advantages of direct sagittal scans are (1) the recognition of localization and extension of the lesion. (2) the evaluation of the extent of the deep facial and nasopharygeal tumors, especially in the intracranial and intraorbital regions. (3) the more accurate determination of staging of the maxillary cancer. (author)

  4. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  5. Initial water quantification results using neutron computed tomography

    International Nuclear Information System (INIS)

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  6. Optimizing the regularization for image reconstruction of cerebral diffuse optical tomography.

    Science.gov (United States)

    Habermehl, Christina; Steinbrink, Jens; Müller, Klaus-Robert; Haufe, Stefan

    2014-09-01

    Functional near-infrared spectroscopy (fNIRS) is an optical method for noninvasively determining brain activation by estimating changes in the absorption of near-infrared light. Diffuse optical tomography (DOT) extends fNIRS by applying overlapping “high density” measurements, and thus providing a three-dimensional imaging with an improved spatial resolution. Reconstructing brain activation images with DOT requires solving an underdetermined inverse problem with far more unknowns in the volume than in the surface measurements. All methods of solving this type of inverse problem rely on regularization and the choice of corresponding regularization or convergence criteria. While several regularization methods are available, it is unclear how well suited they are for cerebral functional DOT in a semi-infinite geometry. Furthermore, the regularization parameter is often chosen without an independent evaluation, and it may be tempting to choose the solution that matches a hypothesis and rejects the other. In this simulation study, we start out by demonstrating how the quality of cerebral DOT reconstructions is altered with the choice of the regularization parameter for different methods. To independently select the regularization parameter, we propose a cross-validation procedure which achieves a reconstruction quality close to the optimum. Additionally, we compare the outcome of seven different image reconstruction methods for cerebral functional DOT. The methods selected include reconstruction procedures that are already widely used for cerebral DOT [minimum l2-norm estimate (l2MNE) and truncated singular value decomposition], recently proposed sparse reconstruction algorithms [minimum l1- and a smooth minimum l0-norm estimate (l1MNE, l0MNE, respectively)] and a depth- and noise-weighted minimum norm (wMNE). Furthermore, we expand the range of algorithms for DOT by adapting two EEG-source localization algorithms [sparse basis field expansions and linearly

  7. Role of computed tomography in pancreatic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Kim, Ki Whang; Lee, Jong Tae; Oh, Sei Jung [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1991-03-15

    At Yonsei University Hospital from January 1984 to August 1990, computed tomographic (CT) scans of 13 patients with surgically proven pancreatic injuries after blunt abdominal trauma, including 6 pancreatic lacerations or contusions, 6 pancreatic fractures, and one post-traumatic pseudocyst, were retrospectively reviewed to determine the role and accuracy of the CT in evaluating pancreatic injury. CT can document gross pancreatic injury by showing focal or diffuse enlargement (1), area of diminished attenuation (3), separation (5), focal hematoma (2), and peripancreatic change, including peripancreatic hematoma (2), fluid collection (11), perirenal fascial thickening (10), omental and mesenteric change (5), and bowel change (2). CT correctly diagnosed pancreatic fracture in 5 cases, post-raumatic pseudocyst in 1 case, and pancreatic laceration in 3 cases in 9 of these patients. There were 4 false negative diagnoses, including 3 pancreatic lacerations and 1 pancreatic fracture. A CT is of pancreatic trauma could be difficult to diagnosis in patients who are scanned within 24 hrs after an injury or to distinguish a motion or streak artifact caused by a nasogastric tube or air-oral contrast fluid level in the stomach.

  8. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  9. Does distracting pain justify performing brain computed tomography in multiple traumas with mild head injury?

    Science.gov (United States)

    Sadeghian, Homa; Motiei-Langroudi, Rouzbeh

    2016-06-01

    Traumatic brain injury (TBI) is a significant health concern classified as mild, moderate, and severe. Although the indications to perform brain computed tomography (CT) are clear in moderate and severe cases, there still exists controversy in mild TBI (mTBI). We designed the study to evaluate the significance of distracting pain in patients with mTBI. The study population included patients with mild traumatic brain injury (GCS ≥13). Moderate and high risk factors including age cerebral edema in brain CT (p > 0.99). No patients had any neurologic symptoms or signs in follow-up. Our results show that in the absence of any other risk factors, distracting pain from other organs (limbs, pelvis, and non-cervical spine) cannot be regarded as a brain CT indication in patients with mild TBI, as it is never associated with significant intracranial lesions. PMID:26931118

  10. Deoxyglucose method for the estimation of local myocardial glucose metabolism with positron computed tomography

    International Nuclear Information System (INIS)

    The deoxyglucose method originally developed for measurements of the local cerebral metabolic rate for glucose has been investigated in terms of its application to studies of the heart with positron computed tomography (PCT) and FDG. Studies were performed in dogs to measure the tissue kinetics of FDG with PCT and by direct arterial-venous sampling. The operational equation developed in our laboratory as an extension of the Sokoloff model was used to analyze the data. The FDG method accurately predicted the true MMRGlc even when the glucose metabolic rate was normal but myocardial blood flow (MBF) was elevated 5 times the control value or when metabolism was reduced to 10% of normal and MBF increased 5 times normal. Improvements in PCT resolution are required to improve the accuracy of the estimates of the rate constants and the MMRGlc

  11. Combined use of ultrasound and computed tomography in the evaluation of fetal intracranial abnormilaty

    International Nuclear Information System (INIS)

    Antenatal ultrasonic findings in two pregnancies with fetal intracranial abnormality were completed by taking a restricted number of computed tomography (CT) scans under ultrasonic control. General information achieved by CT was not greater compared with ultrasonography. CT demonstrated better than ultrasound the calcified areas in the intracranial teratoma of the fetus. In the case of fetal hydrocephaly the existence of a dilated, but otherwise intact cerebral ventricular system was established CT after a somewhat controversial ultrasonic finding. CT can be used as a complementary examination when there are specific problems to be evaluated after antenatal ultrasonic scanning. CT should be used in these cases under ultrasonic control and the information of the both methods must be combined for the clinical decisions. (orig.)

  12. Brain perfusion single photon emission computed tomography in children after acute encephalopathy

    International Nuclear Information System (INIS)

    We studied single photon emission computed tomography (SPECT) of 15 children with acute encephalopathy after more than 1 year from the onset, using technetium-99 m-L, L-ethyl cystinate dimer (99mTc-ECD) and a three-dementional stereotaxic region of interest template. Regional cerebral blood flow was evaluated and divided in three groups according to the severity of disability: absent or mild, moderate, and severe. There was no abnormality on SPECT in the patients without disability or with mild disability. Diffuse hypoperfusion was shown in the groups with moderate and severe disability. The patients with severe disability showed hypoperfusion in the pericallosal, frontal and central areas which was more pronounced than in the patients with moderate disability. (author)

  13. Regional cerebral blood flow in acute stage ischemic cerebrovascular disease by xenon-133 inhalation and single photon emission computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, Hiroyuki (Akita Univ. (Japan). School of Medicine)

    1989-03-01

    During the period from February 1984 through June 1985, single photon emission computerized tomography (SPECT) with xenon-133 inhalation method has been performed for the measurement of regional cerebral blood flow (rCBF) during the first 48 hours of onset of cerebral infarction (n=71) and transient ischemic attack (n=21). X-ray CT (CT) and carotid arteriography were concurrently performed in all the patients. In repeated studies performed for 15 normal volunteers, rCBF measurement by SPECT was found reproducible. Mean values of rCBF for the right and left cerebral hemispheres were 60.3{plus minus}6.52 and 61.8{plus minus}6.91 ml/100 g/min, respectively. For cerebral infarction, ischemic foci corresponding to clinical symptoms were detected more frequently on SPECT than on CT (93% vs 63%). In all of the evaluable 35 patients with cerebral infarction, rCBF within the first 8 hours of onset was decreased: 31.0 ml/100 g/min for the internal carotid artery (ICA) occlusion and 36.0 ml/100 g/min for the middle cerebral artery (MCA) occlusion. Crossed cerebellar diaschisis was observed in 50% (9/18) for ICA occlusion and 37% (14/38) for MCA occlusion. For transient ischemic attack, there was no significant difference in the detection of ischemic foci between SPECT and CT (38% vs 43%). In detecting small foci especially in the deep regions such as the basal ganglia, SPECT was inferior to CT. Mean rCBF for transient ischemic attack tended to be lower than the normal rCBF (50.7 ml/100 g/min for the right cerebral hemisphere and 50.6 ml/100 g/min for the left cerebral hemisphere). SPECT may aid in predicting prognosis and chosing treatment strategy, as well as in determining cerebral hemodynamics. (N.K.).

  14. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA. PMID:19203747

  15. Computed tomography of coronary artery anomaly - case report

    International Nuclear Information System (INIS)

    Background: Anomalies of coronary vessels can be described as varies group of congenital heart disease, which can have different level of clinical manifestation and changeable pathophysiological mechanisms. Diagnosis and imaging of vessel course is essential before percutaneous angioplasty intervention and coronary artery bypass grafting as well as before implantation of artificial valve. Case Report: Patient with cardiologic history, previously percutaneous intervention were performed and left circumflex coronary artery were assessed as occluded. Computed tomography revealed anomalous origin of patent circumflex branch arising from right Valsava sinus. Conclusions: Selective percutaneus coronary angiography is challenging in case of coronary anomalies, there are only few indirect symptoms of anomalies. The advantage of computed tomography over classic coronarography is visibility of all patent coronary vessels after single administration of contrast medium. It is possible to describe its anatomic relations, evaluation of walls and its changes

  16. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    CERN Document Server

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  17. Computed tomography of the adrenals in patients with tuberculosis

    International Nuclear Information System (INIS)

    We evaluated the adrenals of individuals without tuberculosis (group 1 - G1) and with tuberculosis (group 2 - G2) using computed tomography. The antero-posterior length, the thickness, and the longitudinal length of the adrenals were compared in G1 and G2. The duration of the disease, the occurrence of morphologic abnormalities in G2, the distribution according to sex, age and skin color were also studied. There was difference in the antero-posterior length and thickness of right adrenal between G1 and G2. A higher prevalence of white skin male individuals was observed in G2. There was no association between duration of the disease and the occurrence of morphologic abnormalities in G2. A higher occurrence of adrenal enlargement was observed in G2. The main computed tomography findings in patients with tuberculosis were enlargement of the adrenal without calcification, enlargement of the adrenal with punctiform calcifications, and residual calcification of the adrenal. (author)

  18. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  19. Computer tomography investigation of epilepsy the brain atrophy

    International Nuclear Information System (INIS)

    The problem of brain atrophy in patients with epilepsy is often discussed in literature. The aim of the study is to present the results of computer tomography measurements of ventricular size and sulci of brain of 90 patients with various electro-clinical forms of epilepsy, including males and females at the age of 15 to 70 years. Computer tomography measurements were performed having in mind 6 parameters (frontal horn index, FHI; Huckman's number, HZ; cella media index,CMI; width of the third and the fourth ventricles; sulci). The results were compared to the CT measurements of a control group of 40 healthy males and females in the same age range.The obtained data indicate high percentage of subcortical atrophy among patients with epilepsy. Ventricular dilatation was found to be in light extent occurring most early in the frontal brain regions (frontal horns and lateral ventricles)., furthermore observed in the young age. (author)

  20. Analytic reconstruction approach for parallel translational computed tomography.

    Science.gov (United States)

    Kong, Huihua; Yu, Hengyong

    2015-01-01

    To develop low-cost and low-dose computed tomography (CT) scanners for developing countries, recently a parallel translational computed tomography (PTCT) is proposed, and the source and detector are translated oppositely with respect to the imaging object without a slip-ring. In this paper, we develop an analytic filtered-backprojection (FBP)-type reconstruction algorithm for two dimensional (2D) fan-beam PTCT and extend it to three dimensional (3D) cone-beam geometry in a Feldkamp-type framework. Particularly, a weighting function is constructed to deal with data redundancy for multiple translations PTCT to eliminate image artifacts. Extensive numerical simulations are performed to validate and evaluate the proposed analytic reconstruction algorithms, and the results confirm their correctness and merits. PMID:25882732

  1. Technical competence in cardiovascular magnetic resonance and computed tomography

    International Nuclear Information System (INIS)

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  2. Acute appendicitis: computed tomography findings - an iconographic essay

    International Nuclear Information System (INIS)

    Acute appendicitis is the most important cause of abdominal pain requiring surgical intervention in the Western world. The early diagnosis of this disease is of paramount relevance for minimizing its morbidity. Imaging methods have represented a huge progress in the diagnosis of this entity, which used to be based essentially on clinical history, physical examination and laboratory tests results, considering that 20% to 33% of patients present with atypical symptoms. Diagnostic difficulty is higher in children, the elderly, and women in childbearing age. The main imaging methods for evaluation of acute appendicitis are ultrasound and computed tomography. The present study is aimed at describing the disease physiopathology, commenting main computed tomography technical aspects, demonstrating and illustrating tomographic findings, and describing main differential diagnoses. (author)

  3. Intracranial Carotid Calcification on Cranial Computed Tomography

    Science.gov (United States)

    Subedi, Deepak; Zishan, Umme Sara; Chappell, Francesca; Gregoriades, Maria-Lena; Sudlow, Cathie; Sellar, Robin

    2015-01-01

    Background and Purpose— Intracranial internal carotid artery calcification is associated with cerebrovascular risk factors and stroke, but few quantification methods are available. We tested the reliability of visual scoring, semiautomated Agatston score, and calcium volume measurement in patients with recent stroke. Methods— We used scans from a prospective hospital stroke registry and included patients with anterior circulation ischemic stroke or transient ischemic stroke whose noncontrast cranial computed tomographic scans were available electronically. Two raters measured semiautomatic quantitative Agatston score, and calcium volume, and performed qualitative visual scoring using the original 4-point Woodcock score and a modified Woodcock score, where each image on which the internal carotid arteries appeared was scored and the slice scores summed. Results— Intra- and interobserver coefficient of variations were 8.8% and 16.5% for Agatston, 8.8% and 15.5% for calcium volume, and 5.7% and 5.4% for the modified Woodcock visual score, respectively. The modified Woodcock visual score correlated strongly with both Agatston and calcium volume quantitative measures (both R2=0.84; P<0.0001); calcium volume increased by 0.47-mm/point increase in modified Woodcock visual score. Intracranial internal carotid artery calcification increased with age by all measures (eg, visual score, Spearman ρ=0.4; P=0.005). Conclusions— Visual scores correlate highly with quantitative intracranial internal carotid artery calcification measures, with excellent observer agreements. Visual intracranial internal carotid artery scores could be a rapid and practical method for epidemiological studies. PMID:26251250

  4. Indications and Overuse of Computed Tomography in Minor Head Trauma

    OpenAIRE

    Zargar Balaye Jame, Sanaz; MAJDZADEH, Reza; AKBARI SARI, Ali; Rashidian, Arash; ARAB, Mohammad; Rahmani, Hojjat

    2014-01-01

    Background: Computed Tomography (CT) is a useful diagnostic technology, particularly in accident and emergency departments. Objectives: To identify a comprehensive list of indications for application of CT in patients with minor head trauma (MHT) and to determine appropriateness of its use on the basis of this list. Materials and Methods: A cross-sectional study was conducted in three Imaging centers in Tehran. A panel of experts developed a list of CT indications for MHT by reviewing documen...

  5. Computed tomography and the dilated pancreatic duct: An ominous sign

    Energy Technology Data Exchange (ETDEWEB)

    Palmer Gold, R.; Seaman, W.B.

    1981-01-15

    The main pancreatic duct has been visualized with both ultrasound and computed tomography. A normal pancreatic duct has been reported using CT, and controversy persists over whether a normal duct can be routinely imaged with ultrasound. The dilated pancreatic duct has always been associated with disease - usually pancreatitis or a proximal obstructing pancreatic carcinoma. In the patient with no clinical history or laboratory data suggesting pancreatitis, a dilated pancreatic duct implies a proximal tumor.

  6. Soil Macropore Structure Characterized by X-Ray Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    FENG Jie; ZHANG Jia-Bao; ZHU An-Ning; BI Jing-Wei

    2003-01-01

    Undisturbed soil core with many macropores and disturbed soil core with only one macropore (diameter is 10 mm) were probed by x-ray computed tomography (CT). The size, number, shape and continuity of macropores in the transverse and vertical sections of soil were characterized using CT scanning images. The probability densities of macropores in the transverse section of soil core exhibited a logarithmic Γ distribution.Results indicated that CT scanning was a promising nondestructive method for characterizing macropores in soils.

  7. Internal mammary lymph node biopsy guided by computed tomography

    OpenAIRE

    Irving, Henry C; Hardy, Graham J.

    1982-01-01

    Internal mammary lymph node enlargement may be demonstrated using computed tomography (CT), and a confirmatory tissue diagnosis of metastatic involvement may be obtained using fine needle aspiration biopsy with needle tip placement guided by the CT scanner. A case history is described to illustrate how a patient presented 9 years after mastectomy with an internal mammary lymph node metastasis and how cytopathological diagnosis of this metastasis was achieved by CT guided biopsy.

  8. Experimentally determined spectral optimization for dedicated breast computed tomography

    OpenAIRE

    Prionas, Nicolas D.; Huang, Shih-Ying; Boone, John M.

    2011-01-01

    Purpose: The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material∕thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT tech...

  9. The possibilities of computer tomography in paecilomycosis of lungs

    OpenAIRE

    Abdusalom Ashurov; Rohila Jabbarova

    2010-01-01

    We have analyzed computed tomography (CT) results of chest in 56 patients with lung injures caused by paecilomycosis fungus at the age from 17 to 59 years. In our investigations, the perverted lung pattern due to pathology of interstitial tissue was observed in 52 (93%) patients of 56 (with chronic bronchitis - 100%, exogenous-allergic alveolitis - 93%, recurrent pneumonia - 100% and with bronchial asthma - 80%). Analysis showed that CT provides wide opportunities in visualization of all spec...

  10. Computed tomography in complex fractures of the ankle joint

    International Nuclear Information System (INIS)

    Diagnostic value of conventional roentgen technique and computed tomography is proofed by examination of 50 patients with sprain fractures of the ankle joint. The dimension of destruction of the distal tibial joint surface is better documented by CT than by other radiological techniques. Additional informations like multifragmentation of the distal tibia or evaluation of reposition impedigment are found more frequently by CT. Therefore indication and planning of the traumatherapy can be assessed better by the traumatologist. (orig.)

  11. The bipartite tarsal navicular bone: radiographic and computed tomography findings

    International Nuclear Information System (INIS)

    Two cases of bipartite tarsal navicular bone are presented. The radiographic and computed tomography (CT) findings of this anatomical variant are described. Correct recognition of this entity is important, both because it may be the cause of symptoms per se, and because it may be misdiagnosed as a fracture. When plain films are not diagnostic, CT scanning is helpful in distinguishing between a fracture and this variant. 6 refs., 4 figs

  12. Pulmonary Thromboembolic Disease: A New Role for Computed Tomography

    OpenAIRE

    Olsan, Adam D.; Matthews, Charles C.; Sullivan, Michael A.

    2002-01-01

    Over the past few years, computed tomography (CT) has emerged as a common noninvasive, definitive, alternative to ventilation-perfusion scintigraphy scan and pulmonary angiography in the evaluation of patients suspected of having pulmonary emboli. Additionally, recent articles have investigated the possibility of using CT to identify deep venous thrombi following a spiral CT pulmonary angiogram. Using the same bolus of contrast as that administered for a CT pulmonary angiogram, the ultimate g...

  13. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  14. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  15. Application of neutron computed tomography in the geosciences

    OpenAIRE

    Wilding, M; Shields, K.; Lesher, C. E.

    2005-01-01

    A research program that applies neutron computed tomography (CT) to geological problems has been developed at the McClellan Nuclear Radiation Center (UCD-MNRC) owned and operated by the University of California, Davis (UCD-MNRC). The high penetration of neutrons, their sensitivity to light elements, and their special sensitivity to hydrogen (in water or organic materials) make them an ideal tool for non-destructive examination of complex materials of geological interest. There are four resear...

  16. Fast neutron computed tomography with TV imaging at YAYOI

    International Nuclear Information System (INIS)

    A highly sensitive scintillation converter was used for the fast neutron television (FNTV) method. We examined the fast neutron computed tomography (FNCT) using the television (TV) method and evaluated the total CT imaging system by the modulation transfer function (MTF). The MTF evaluation showed the spatial resolution to be 1.4 mm. This was two or three times larger than the pixel size. The spatial resolution was restricted by pixel size in the present FNTV-CT system. (orig.)

  17. Establishing normal reference values in quantitative computed tomography of emphysema

    OpenAIRE

    Smith, Benjamin M.; Barr, R Graham

    2013-01-01

    Quantitative computed tomography (QCT) can provide reliable and valid measures of lung structure and volumes. Similar to lung function and volumes measured by spirometry, lung measures obtained by QCT vary by demographic and anthropomorphic factors including sex, race/ethnicity and height in asymptomatic non-smokers. Hence, some accounting for these factors is necessary to define abnormal from normal QCT values and disease severity. Similar to spirometry and cardiac volumes, prediction equati...

  18. Use of dentomaxillofacial cone beam computed tomography in dentistry

    OpenAIRE

    KAMBUROĞLU, Kıvanç

    2015-01-01

    Cone-beam computed tomography (CBCT) was developed and introduced specifically for dento-maxillofacial imaging. CBCT possesses a number of advantages over medical CT in clinical practice, such as lower effective radiation doses, lower costs, fewer space requirements, easier image acquisition, and interactive display modes such as mutiplanar reconstruction that are applicable to maxillofacial imaging. However, the disadvantages of CBCT include higher doses than two-dimensional imaging; the ina...

  19. Quantitative computed tomography imaging of airway remodeling in severe asthma

    OpenAIRE

    Grenier, Philippe A.; Fetita, Catalin I.; Brillet, Pierre-Yves

    2016-01-01

    Asthma is a heterogeneous condition and approximately 5–10% of asthmatic subjects have severe disease associated with structure changes of the airways (airway remodeling) that may develop over time or shortly after onset of disease. Quantitative computed tomography (QCT) imaging of the tracheobronchial tree and lung parenchyma has improved during the last 10 years, and has enabled investigators to study the large airway architecture in detail and assess indirectly the small airway structure. ...

  20. An Evaluation of a Prototype Proton Computed Tomography Scanner

    OpenAIRE

    Plautz, Tia Elizabeth

    2016-01-01

    Since the 1990s, the number of clinical proton therapy facilities around the world has been growing exponentially. Because of this, and the lack of imaging support for proton therapy in the treatment room, a renewed interest in proton radiography and computed tomography (CT) has emerged. This imaging modality was largely abandoned in the 1970s and '80s in favor of the already successful x-ray CT, for reasons including long acquisition times and inadequate spatial resolution. Protons are parti...

  1. Computed tomography in patients with Ehlers-Danlos syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi; Sugitani, Akitoshi; Eda, Isematsu; Takashima, Sachio; Takeshita, Kenzo

    1985-09-01

    Three patients with Ehlers-Danlos syndrome were reported. Unusual findings on computed tomography were seen in two of the three patients. One case showed peculiar and marked dilatation of the 4th ventricle, supracerebellar cistern and lateral ventricle. The other case presented disproportionate enlargement of the anterior horn of the lateral ventricle. These CT findings in the two patients suggest that developmental abnormalities may constitute a structural defect.

  2. Use of Cone Beam Computed Tomography in Endodontics

    Directory of Open Access Journals (Sweden)

    William C. Scarfe

    2009-01-01

    Full Text Available Cone Beam Computed Tomography (CBCT is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics.

  3. Role of computed tomography in the study of vascular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Bicego, E.; Bergamo, I.A. and others

    1988-01-01

    The most important indications to the use of computed tomography (CT) in the study of vascular pathology are considered. They may be divided as follows: 1) demonstration of vascular involvement by thoraco-abdominal neoplasms; 2) differential diagnosis between primary vascular and extra-vascular pathology; 3) assessment of primary arterial pathology. For each group, those pathologies are considered, for which CT plays a fundamental role.

  4. Abdominal Computed Tomography Findings of Malaria Infection with Plasmodium vivax

    OpenAIRE

    Kim, Eun Mi; Cho, Hyeon Je; Cho, Chong Rae; Kwak, Yee Gyung; Kim, Mi Young; Cho, Yun Ku

    2010-01-01

    Abdominal computed tomography (CT) findings of malaria are not well-known even though malaria is a serious infectious disease. To identify abdominal CT findings, we selected 34 of 405 patients who had a positive peripheral blood smear for Plasmodium vivax and had underwent abdominal CT as the malaria group. We also selected 80 patients who had fever and a negative peripheral blood smear as the control group and 120 healthy people as the normal group. We reviewed and analyzed their medical rec...

  5. Computed tomography changes following cryotherapy for hepatic cancer

    International Nuclear Information System (INIS)

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment

  6. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  7. Use of Cone Beam Computed Tomography in Endodontics

    OpenAIRE

    Scarfe, William C.; Levin, Martin D.; David Gane; Allan G. Farman

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imagin...

  8. Multidetector computed tomography of the coronary arteries - pictorial essay

    International Nuclear Information System (INIS)

    Multidetector computed tomography (MDCT) is being used more frequently for the detection of atherosclerotic coronary artery disease (CAD). MDCT allows for very rapid image acquisition with little motion artifact, resulting in the ability to quantitate calcified atherosclerotic plaque. Congenital coronary artery anomalies are readily identified using this technique. A key advantage is the noninvasiveness of the study, with no intravascular contrast media needed. Knowledge of coronary artery anatomy as well as of the potential pitfalls is required. (author)

  9. Computed Tomography Inspection and Analysis for Additive Manufacturing Components

    Science.gov (United States)

    Beshears, Ronald D.

    2016-01-01

    Computed tomography (CT) inspection was performed on test articles additively manufactured from metallic materials. Metallic AM and machined wrought alloy test articles with programmed flaws were inspected using a 2MeV linear accelerator based CT system. Performance of CT inspection on identically configured wrought and AM components and programmed flaws was assessed using standard image analysis techniques to determine the impact of additive manufacturing on inspectability of objects with complex geometries.

  10. Thermal Neutron Computed Tomography of Soil Water and Plant Roots

    OpenAIRE

    Leanne G. Tumlinson; Hungyuan Liu; Wendy K. Silk; Hopmans, Jan W.

    2007-01-01

    Neutron radiography is a noninvasive imaging technique that measures the attenuation of thermal neutrons, as is done with x-ray and γ-ray radiography, to characterize the internal composition of materials. Neutron and x-ray imaging are complementary techniques, with neutron imaging especially well suited for materials containing H atoms and other low-atomic-weight attenuating materials. Although neutron computed tomography (NCT) techniques are routinely used in engineering, relatively little ...

  11. Computed tomography in complex fractures of the ankle joint

    Energy Technology Data Exchange (ETDEWEB)

    Friedburg, H.; Wimmer, B.; Hendrich, V.; Riede, U.N.

    1983-09-01

    Diagnostic value of conventional roentgen technique and computed tomography is proofed by examination of 50 patients with sprain fractures of the ankle joint. The dimension of destruction of the distal tibial joint surface is better documented by CT than by other radiological techniques. Additional informations like multiframentation of the distal tibia or evaluation of reposition impediment are found more frequently by CT. Therefore indication and planning of the traumatherapy can be assessed better by the traumatologist.

  12. [Multislice spiral computed tomography in the diagnosis of osteomyelitis].

    Science.gov (United States)

    Egorova, E A; Zorina, I S; Sangaeva, L M

    2010-01-01

    This paper deals with the results of a radiation study in 34 patients with the clinical manifestations of maxillofacial osteomyelitides. It describes the radiation semiotics of changes occurring in the bone and its surrounding soft tissues of the maxillofacial region in different phases of osteomyelitis. Comparative analysis of orthopantograms and images obtained by multislice spiral computed tomography revealed the benefits of the latter in detecting soft tissue changes and subtle bone alterations.

  13. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    OpenAIRE

    Kezban Berberoğlu

    2016-01-01

    Radiotherapy (RT) plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT) during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly ...

  14. SADMFR Guidelines for the Use of Cone-Beam Computed Tomography/Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Benic, Goran I; Bornstein, Michael; Dagassan-Berndt, Dorothea; Filippi, Andreas; Hicklin, Stefan; Kissling-Jeger, Franziska; Luebbers, Heinz-Theo; Sculean, Anton; Sequeira-Byron, Patrick; Walter, Clemens; Zehnder, Matthias

    2015-01-01

    In 2011, the first consensus conference on guidelines for the use of cone-beam computed tomography (CBCT) was convened by the Swiss Society of Dentomaxillofacial Radiology (SGDMFR). This conference covered topics of oral and maxillofacial surgery, temporomandibular joint dysfunctions and disorders, and orthodontics. In 2014, a second consensus conference was convened on guidelines for the use of CBCT in endodontics, periodontology, reconstructive dentistry and pediatric dentistry. The guideli...

  15. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  16. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  17. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  18. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  19. Correlation of echoencephalography and computer tomography in expansive brain lesions

    International Nuclear Information System (INIS)

    50 patients with confirmed expansive intracranial processes were examined by two methods - echoencephalography and computer tomography. The deviation of the middle echo from two points on the calva and the corresponding deviation of septum pellucidum and epiphysis according to the computer tomography examination were compared. The findings are not quite identical. As a rule there is a minor deviation in echoencephalography examinations as compared with the deviation of corresponding structures according to computer tomography, the difference, however, does not exceed 3 mm. Echoencephalography examinations made at two different points on the calva increase the accuracy and sensitivity of the finding. In expansive processes with a more lateral and posterior localization we usually do not only find greater shifts of the echoencephalography in the anterior as well as posterior temporal region but also an increased difference between the two deviations. Despite the use of most up-to-date diagnostic methods echoencephalography remains a rapid, low-cost and unpretentious method in neurology and neurosurgery. It provides, however, only information for orientation and is biassed with an 5 to 8% error. (author)

  20. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  1. Hepatic hemangiomas as diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    A total of 62 cases where the clinical diagnosis of hepatic hemangioma had been established during the period between 1981 and 1983 on the basis of computed tomography and sonography were subjected to retrospective analysis with the aim of evaluating the diagnostic reliability of these two methods. In 29 patients a typical distribution pattern of the contrast medium gave irrefutable evidence of the disease. Hemangiomas were predicted from the results of computed tomography for a further 5 patients with less revealing distribution patterns, although in 4 among these the preliminary diagnosis of hemangioma was disproved by additional diagnostic procedures (scintigraphy, laparoscopy, surgery and biopsy). Out of 16 patients, in which the hemangiomas were diagnosed from the typical patterns created by the contrast medium on the CT scans, 11 showed sonographic findings to confirm the presence of such tumours. This retrospective analysis showed that a correct and positive diagnosis could be established in no more than 7 patients on the basis of sonography alone, while 6 such diagnoses were definitely proven to be false-positive. As regards diagnostic accuracy, sonography clearly compares unfavourably with computed tomography. It may offer some advantages inasmuch as it requires no radiation exposure, is non-invasive and, last not least, less costly. (ECB)

  2. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  3. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  4. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  5. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Martinez, A Preite; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C; Gargano, G; Magro, R; Santoro, M; Stumbo, S; 10.1088/1748-0221/2/09/P09007

    2009-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  6. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  7. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y;

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...... myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative...

  8. Nonoperative treatment of splenic trauma: usefulness of computed tomography

    International Nuclear Information System (INIS)

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  9. Quantitative cerebral perfusion assessment using microscope-integrated analysis of intraoperative indocyanine green fluorescence angiography versus positron emission tomography in superficial temporal artery to middle cerebral artery anastomosis

    Directory of Open Access Journals (Sweden)

    Shinya Kobayashi

    2014-01-01

    Full Text Available Background: Intraoperative qualitative indocyanine green (ICG angiography has been used in cerebrovascular surgery. Hyperperfusion may lead to neurological complications after superficial temporal artery to middle cerebral artery (STA-MCA anastomosis. The purpose of this study is to quantitatively evaluate intraoperative cerebral perfusion using microscope-integrated dynamic ICG fluorescence analysis, and to assess whether this value predicts hyperperfusion syndrome (HPS after STA-MCA anastomosis. Methods: Ten patients undergoing STA-MCA anastomosis due to unilateral major cerebral artery occlusive disease were included. Ten patients with normal cerebral perfusion served as controls. The ICG transit curve from six regions of interest (ROIs on the cortex, corresponding to ROIs on positron emission tomography (PET study, was recorded. Maximum intensity (I MAX , cerebral blood flow index (CBFi, rise time (RT, and time to peak (TTP were evaluated. Results: RT/TTP, but not I MAX or CBFi, could differentiate between control and study subjects. RT/TTP correlated (|r| = 0.534-0.807; P < 0.01 with mean transit time (MTT/MTT ratio in the ipsilateral to contralateral hemisphere by PET study. Bland-Altman analysis showed a wide limit of agreement between RT and MTT and between TTP and MTT. The ratio of RT before and after bypass procedures was significantly lower in patients with postoperative HPS than in patients without postoperative HPS (0.60 ± 0.032 and 0.80 ± 0.056, respectively; P = 0.017. The ratio of TTP was also significantly lower in patients with postoperative HPS than in patients without postoperative HPS (0.64 ± 0.081 and 0.85 ± 0.095, respectively; P = 0.017. Conclusions: Time-dependent intraoperative parameters from the ICG transit curve provide quantitative information regarding cerebral circulation time with quality and utility comparable to information obtained by PET. These parameters may help predict the occurrence of postoperative

  10. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  11. Regional cerebral glucose metabolism in late-life depression and Alzheimer disease: a preliminary positron emission tomography study.

    OpenAIRE

    Kumar, A; Newberg, A; A. Alavi; Berlin, J; Smith, R.; Reivich, M

    1993-01-01

    Eight subjects with late-life depression, eight subjects with probable Alzheimer disease, and eight healthy age-matched controls were studied using 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography in the resting state with their eyes open and ears unoccluded. The depressed subjects showed widespread reductions in the regional cerebral metabolic rate for glucose in most major neocortical, subcortical, and paralimbic regions that were significantly different from control values (P <...

  12. The computed tomographic appearance of cerebral cysticercosis in adults and children

    International Nuclear Information System (INIS)

    The computed tomographic (CT) scans of 45 patients (30 adults, 15 children) with cerebral cysticercosis were reviewed. These patients had undergone complete diagnostic evaluations including skin tests, laboratory tests, plain skull radiography, radionuclide brain scanning, CT, and cerebral angiography. All of these tests were unrewarding except CT and the indirect hemagglutination tests on the serum. A classification of cerebral cysticercosis based on the location of the lesions in the brain and the CT appearance was developed. Cerebral cysticercosis can be diagnosed by CT findings when there is also a history of seizures and of the patient having lived in an area where the disease is endemic

  13. The computed tomographic appearance of cerebral cysticercosis in adults and children

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, S.E.; Locke, G.E.; Biggers, S.; Percy, A.K.

    1982-09-01

    The computed tomographic (CT) scans of 45 patients (30 adults, 15 children) with cerebral cysticercosis were reviewed. These patients had undergone complete diagnostic evaluations including skin tests, laboratory tests, plain skull radiography, radionuclide brain scanning, CT, and cerebral angiography. All of these tests were unrewarding except CT and the indirect hemagglutination tests on the serum. A classification of cerebral cysticercosis based on the location of the lesions in the brain and the CT appearance was developed. Cerebral cysticercosis can be diagnosed by CT findings when there is also a history of seizures and of the patient having lived in an area where the disease is endemic.

  14. Craniocerebral trauma--congruence between post-mortem computed tomography diagnoses and autopsy results: a 2-year retrospective study

    DEFF Research Database (Denmark)

    Jacobsen, Christina; Lynnerup, Niels

    2010-01-01

    Computed tomography (CT) has been used routinely at the Department of Forensic Medicine, University of Copenhagen since 2002. A retrospective study was performed in order to correlate CT-scan based diagnoses of cranial and cerebral lesions with macroscopic autopsy diagnoses in 56 cases. The CT......-scans were performed by a forensic pathologist. They were obtained by using two different CT-scan protocols. The results showed correct skull fracture diagnoses in 34/56 cases. Fractures were diagnosed partially (9) or missed totally (13) on CT-images in 22 cases. The agreement for fracture diagnoses...

  15. Depressed cerebral oxygen metabolism in patients with chronic renal failure. A positron emission tomography study

    International Nuclear Information System (INIS)

    In order to elucidate brain oxygen metabolism in uremic patients, the regional cerebral blood flow (rCBF), oxygen extraction (rOEF) and oxygen metabolism (rCMRO2) were measured by positron emission tomography (PET) in both 10 hemodialysis patients (HD: male [m]/female [f]=2/8, age of 49±3 [SEM] years old, HD duration of 113±26 months) and 13 pre-dialysis renal failure patients (CRF: m/f=10/3, age of 61±2 years old, serum creatinine (SCr) of 6.3±1.0 mg/dl). Data were compared with 20 non-uremic subjects (Control: m/f=7/13, age of 62±2 years old, SCr of 0.9±0.1 mg/dl). They had no neurological abnormalities, congestive heart failure, history of cerebrovascular accident, diabetes mellitus, or symptomatic brain lesion on magnetic resonance imaging. The age of HD was significantly younger than the other groups (p2 in both HD (1.82±0.10 ml/min/100 g) and CRF (1.95±0.09) showed significantly lower values as compared to Control (2.23±0.05) (p<0.01, respectively). Hemispheric rCBF in HD (35.6±2.1 ml/100 g/min) and in CRF (36.1±2.1) were not different from that in Control (31.8±1.4). Hemispheric rOEF in CRF (45.7±1.6%) was significantly higher than that in Control (40.5±1.2%) (p<0.02), but that in HD (43.7±1.9%) did not increase significantly. These tendencies were similar in all regions of interest, especially in the cerebral cortices, but not in the cerebellum. All PET parameters in the frontal cortices tended to show the lowest value in renal failure patients. For all HD patients, rCBF in both the frontal cortex and the white matter correlated inversely with HD duration (frontal cortex: r=-0.649, p<0.05; white matter: r=-0.706, p<0.02). Based on these data, it is concluded that brain oxygen metabolism is depressed in renal failure patients on or before hemodialysis treatment. The cause for the depressed brain oxygen metabolism is considered to be due either to the dysregulation of cerebral circulation or to lower brain cell activity. (author)

  16. Observation of the pulp horn by swept source optical coherence tomography and cone beam computed tomography

    Science.gov (United States)

    Iino, Yoshiko; Yoshioka, Toshihiko; Hanada, Takahiro; Ebihara, Arata; Sunakawa, Mitsuhiro; Sumi, Yasunori; Suda, Hideaki

    2015-02-01

    Cone-beam computed tomography (CBCT) is one of the most useful diagnostic techniques in dentistry but it involves ionizing radiation, while swept source optical coherence tomography (SS-OCT) has been introduced recently as a nondestructive, real-time, high resolution imaging technique using low-coherence interferometry, which involves no ionizing radiation. The purpose of this study was to evaluate the ability of SS-OCT to detect the pulp horn (PH) in comparison with that of CBCT. Ten extracted human mandibular molars were used. After horizontally removing a half of the tooth crown, the distance from the cut dentin surface to PH was measured using microfocus computed tomography (Micro CT) (SL) as the gold standard, by CBCT (CL) and by SS-OCT (OL). In the SS-OCT images, only when PH was observed beneath the overlying dentin, the distance from the cut dentin surface to PH was recorded. If the pulp was exposed, it was defined as pulp exposure (PE). The results obtained by the above three methods were statistically analyzed by Spearman's rank correlation coefficient at a significance level of p images correlated closely with CBCT images, suggesting that SS-OCT can be a useful tool for the detection of PH.

  17. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly.

  18. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    International Nuclear Information System (INIS)

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  19. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson, E-mail: edmarchiori@gmail.com [Fluminense Federal University, Rio de Janeiro (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Valiante, Paulo Marcos, E-mail: valiante.rlk@terra.com.br [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Mano, Claudia Mauro, E-mail: cacaumano@gmail.com [Fluminense Federal University, Rio de Janeiro (Brazil); Zanetti, Glaucia, E-mail: glauciazanetti@gmail.com [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Petropolis Faculty of Medicine, Rio de Janeiro (Brazil); Escuissato, Dante L., E-mail: danteescuissato@gmail.com [Federal University of Parana, Curitiba (Brazil); Souza, Arthur Soares, E-mail: asouzajr@gmail.com [Faculty of Medicine of Rio Preto, Sao Paulo (Brazil); Capone, Domenico, E-mail: domenicocap@gmail.com [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2011-01-15

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  20. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)