WorldWideScience

Sample records for central venous occlusions

  1. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    Science.gov (United States)

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, pvenous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  2. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  3. Laser Recanalization of Central Venous Occlusion to Salvage a Threatened Arteriovenous Fistula.

    Science.gov (United States)

    Rambhia, Sagar; Janko, Matthew; Hacker, Robert I

    2018-07-01

    Central venous occlusion is conventionally managed with balloon angioplasty, stent extension, or sharp recanalization. Here, we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained 2 years postintervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Streitparth, Florian; Gebauer, Bernhard; Benter, Thomas

    2010-01-01

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.

  5. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  6. Regarding optical coherence tomography grading of ischemia in central retinal venous occlusion

    Directory of Open Access Journals (Sweden)

    Tripathy K

    2017-02-01

    Full Text Available Koushik TripathyDepartment of Vitreoretina and Uvea, ICARE Eye Hospital & Postgraduate Institute, Noida, Uttar Pradesh, IndiaThe author read with interest the article by Browning et al.1 The author humbly wants to discuss a few facts.1. The article1 discusses grading of retinal ischemia based on optical coherence tomography features in central retinal venous occlusion. As coexisting central retinal arterial occlusion or cilioretinal arterial occlusion may also cause inner retinal hyper-reflectivity, exclusion of such cases is an important consideration before implicating central retinal venous occlusion for the ischemia. Extensive intraretinal hemorrhages are other important hindrances to the evaluation of the perfusion status of the retina using both fluorescein angiogram and optical coherence tomography.2. It would be interesting to know the gonioscopic findings, especially neovascularization of the anterior chamber angle if it was performed at presentation and during the follow-ups.3. The manuscript documented that the incidence of anterior segment neovascularization at 1 year was 8.9% in severe ischemia group.1 The incidence of anterior segment neovascularization in perfused groups was higher (15.4% and 17.6% for mild and moderate ischemia, respectively. Although the sample size was low, such findings are contrary to the literature2 and require further discussion. Authors' replyDavid J Browning, Omar S Punjabi, Chong LeeDepartment of Ophthalmology, Charlotte Eye, Ear, Nose and Throat Associates, P.A., Charlotte, NC, USA We thank Dr Tripathy for his interest in our article and would respond to his above-mentioned points.1. We agree that excluding eyes with cilioretinal artery and central retinal artery occlusions is necessary to be able to attribute inner retinal reflectivity changes to central retinal vein occlusion. Cilioretinal artery occlusion is associated with a band of ischemic retinal whitening and central retinal artery occlusion

  7. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  8. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices

  9. Central venous obstruction in the thorax

    International Nuclear Information System (INIS)

    Collin, G.; Jones, R.G.; Willis, A.P.

    2015-01-01

    Central venous stenosis and occlusion can occur secondary to a spectrum of conditions ranging from aggressive malignancy to benign extrinsic anatomical compression in otherwise healthy individuals. Irrespective of aetiology, significant morbidity in the acute setting and long term can occur unless prompt accurate diagnosis and appropriate management is initiated, the radiologist being central to both. The present review will provide radiologists with a thorough illustration and explanation of the range of central venous conditions in the thorax (including deep vein thrombosis, thoracic outlet syndrome, haemodialysis, and malignancy related causes), the salient imaging findings and interventional management using case examples from the authors' practice. - Highlights: • We show a range of causes of central venous disease in the thorax. • We provide information about different imaging and management strategies. • We show several cases with successes and complications of endovascular management

  10. Case report: Unilateral conduction hearing loss due to central venous occlusion.

    Science.gov (United States)

    Ribeiro, Phillip; Patel, Swetal; Qazi, Rizwan A

    2016-05-07

    Central venous stenosis is a well-known complication in patients with vascular access for hemodialysis. We report two cases involving patients on hemodialysis with arteriovenous fistulas who developed reversible unilateral conductive hearing loss secondary to critical stenosis of central veins draining the arteriovenous dialysis access. A proposed mechanism for the patients' reversible unilateral hearing loss is pterygoid venous plexus congestion leading to decreased Eustachian tube patency. Endovascular therapy was conducted to treat the stenosis and the hearing loss of both patients was returned to near normal after successful central venous angioplasty.

  11. Advantages and disadvantages of peripherally inserted central venous catheters (PICC) compared to other central venous lines: a systematic review of the literature.

    Science.gov (United States)

    Johansson, Eva; Hammarskjöld, Fredrik; Lundberg, Dag; Arnlind, Marianne Heibert

    2013-06-01

    The use of central venous lines carries a significant risk for serious complications and high economic costs. Lately, the peripherally inserted central venous catheter (PICC) has gained in popularity due to presumed advantages over other central venous lines. The aim of this systematic literature review was to identify scientific evidence justifying the use of PICC. The literature review was performed according to the principles of Cochrane Collaboration. The electronic literature search included common databases up to March 2011. Only those studies rated as high or moderate quality were used for grading of evidence and conclusions. The search resulted in 827 abstracts, 48 articles were read in full text, and 11 met the inclusion criteria. None of the articles was classified as high quality and two had moderate quality. The results of these two studies indicate that PICC increases the risk for deep venous thrombosis (DVT), but decreases the risk for catheter occlusion. The quality of scientific evidence behind these conclusions, however, was limited. Due to the lack of studies with sufficiently high quality, questions such as early complications, patient satisfaction and costs could not be answered. We conclude that although PICCs are frequently used in oncology, scientific evidence supporting any advantage or disadvantage of PICC when comparing PICC with traditional central venous lines is limited, apart from a tendency towards increased risk for DVT and a decreased risk for catheter occlusion with PICC.

  12. Central venous obstruction in hemodialysis patients: the usefulness of percutaneous treatment

    International Nuclear Information System (INIS)

    Kim, Cheol Young; Goo, Dong Erk; Kim, Dae Ho; Hong, Hyun Suk; Lee, Hae Kyoung; Choi, Duk Lin; Yang, Sung Boo; Moon, Chul

    2002-01-01

    To analyse the effectiveness of percutaneous treatment of central venous obstruction in patients undergoing hemodialysis. In 100 patients, 107 central venous strictures (56 subclavian (occlusion:21, stenosis:35) and 51 innominate (occlusion:23,stenosis:28)) were assessed, and 170 percutaneous angioplasty procedures were performed. Balloon dilation of the venous lumen was the preferred mode, but if dilation was incomplete we inserted a stent at the site of the stricture. Technical success, procedural complications and the long-term patency rate were evaluated, and the patency difference according to location and degree of stricture, the existence of DM, and any history of central catheter insertion was also determined. We inserted 52 stents in 170 procedures, in 157 (92.4%) of which initial technical success was achieved. Stent migration occurred in two cases and balloon rupture in three. The 6- and 12-month primary patency rates were 46.2% and 24.1%, respectively, and the mean patency rate was 8.5 months. The 1-, 2-and 3-year accumulative patency rates were 59.8%, 47.5% and 35.7%, respectively, and the mean patency rate was 23.5 months. Other than in the history of central catheter insertion, there were no statistically significant differences in patency rates (p=0.0128). In hemodialysis patients with a central venous stricture, percutaneous angioplasty is a safe and useful procedure, but to maintain long-term central venous patency, repeated interventions are required

  13. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  14. Central Venous Disease in Hemodialysis Patients: An Update

    Energy Technology Data Exchange (ETDEWEB)

    Modabber, Milad, E-mail: mmodabber@gmail.com [McMaster University, Michael G. DeGroote School of Medicine (Canada); Kundu, Sanjoy [Scarborough Hospital and Scarborough Vascular Ultrasound, The Vein Institute of Toronto (Canada)

    2013-08-01

    Central venous occlusive disease (CVD) is a common concern among the hemodialysis patient population, with the potential to cause significant morbidity. Endovascular management of CVD, comprising percutaneous balloon angioplasty and bare-metal stenting, has been established as a safe alternative to open surgical treatment. However, these available treatments have poor long-term patency, requiring close surveillance and multiple repeat interventions. Recently, covered stents have been proposed and their efficacy assessed for the treatment of recalcitrant central venous stenosis and obstruction. Moreover, newly proposed algorithms for the surgical management of CVD warrant consideration. Here, we seek to provide an updated review of the current literature on the various treatment modalities for CVD.

  15. [Complications associated to central venous catheters in hematology patients].

    Science.gov (United States)

    García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia

    2015-01-01

    To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  16. Transposition of cephalic vein to rescue hemodialysis access arteriovenous fistula and treat symptomatic central venous obstruction

    Directory of Open Access Journals (Sweden)

    Felipe Jose Skupien

    2014-03-01

    Full Text Available It is known that stenosis or central venous obstruction affects 20 to 50% of patients who undergo placement of catheters in central veins. For patients who are given hemodialysis via upper limbs, this problem causes debilitating symptoms and increases the risk of loss of hemodialysis access. We report an atypical case of treatment of a dialysis patient with multiple comorbidities, severe swelling and pain in the right upper limb (RUL, few alternative sites for hemodialysis vascular access, a functioning brachiobasilic fistula in the RUL and severe venous hypertension in the same limb, secondary to central vein occlusion of the internal jugular vein and right brachiocephalic trunk. The alternative surgical treatment chosen was to transpose the RUL cephalic vein, forming a venous necklace at the anterior cervical region, bypassing the site of venous occlusion. In order to achieve this, we dissected the cephalic vein in the right arm to its junction with the axillary vein, devalved the cephalic vein and anastomosed it to the contralateral external jugular vein, providing venous drainage to the RUL, alleviating symptoms of venous hypertension and preserving function of the brachiobasilic fistula.

  17. Central venous recanalization in patients with short gut syndrome: restoration of candidacy for intestinal and multivisceral transplantation.

    Science.gov (United States)

    Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem

    2005-09-01

    To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.

  18. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  19. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz [Prince Sultan Military Medical City (PSMMC), Division of Endovascular Interventional Radiology, Department of Medical Imaging (Saudi Arabia); Ahmed, Dildar; Aslam, Naveed [Prince Sultan Military Medical City (PSMMC), Department of Nephrology (Saudi Arabia)

    2016-06-15

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  20. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    International Nuclear Information System (INIS)

    Arabi, Mohammad; Ahmed, Ishtiaq; Mat’hami, Abdulaziz; Ahmed, Dildar; Aslam, Naveed

    2016-01-01

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  1. Efficacy and safety of using L-cysteine as a catheter-clearing agent for nonthrombotic occlusions of central venous catheters in children.

    Science.gov (United States)

    Pai, Vinita B; Plogsted, Steven

    2014-10-01

    Critically ill pediatric patients, especially in the intensive care unit, receive multiple medications and have a higher risk of central venous catheter (CVC) occlusion. If an occlusion occurs immediately after the administration of multiple medications or incompatible medications, either an acidic solution such as 0.1 N hydrochloric acid (HCl) or a basic solution of 1 mEq/mL sodium bicarbonate or 0.1 N sodium hydroxide can be used. However, compounding and storing of 0.1 N HCl has become more complex due to USP guidelines for sterile compounding, and an alternative is needed. We report a series of cases in which L-cysteine was used instead of HCl to clear CVCs occluded due to administration of multiple medications. L-cysteine is a commercially available, sterile solution with a pH of 1–2.5. CVC occlusion was resolved in 10 of the 16 episodes in 13 patients. Two of the 16 occlusions were phenytoin related and would not have responded. An L-cysteine dose of 50 mg was used during 10 of the 16 episodes, 100 mg during 5 episodes, and 25 mg during 1 episode. A correlation between catheter clearance and dose was not observed. Occlusion resolution due to L-cysteine was not correlated to the prior use of tissue plasminogen activator. Metabolic acidosis, adverse effects, or damage to the catheters due to L-cysteine were not observed. On the basis of this limited experience, we propose L-cysteine as an effective alternative to 0.1 N HCl for clearing CVC occlusions caused by drugs with an acidic pKa.

  2. Multicenter study in monitoring central venous catheters complications in hematologic patiennts

    Directory of Open Access Journals (Sweden)

    Carmen García Gabás

    2013-05-01

    Full Text Available Most hematological patients suffer a significant venous damage related to different administrated intravenous therapy, being necessary to place central venous catheters (CVC. CVC is associated with various complications. The most common catheter-related complications are occlusion and infection. To avoid such of them, the development of protocols for insertion and care are needed, as well as recording and following up complications. To this end, we propose a cross-sectional carried out during 13 months whose main goal is to know the incidence of CVC- related complications (mainly occlusion and infection in hematological patients.Population included all the =14 ages patients admitted to different hematological units at Ramon y Cajal and Gregorio Marañón hospitals in Madrid and who signed informed consent. Socio-demographic, clinical characteristics and complications were entered into a log which included a pursuit of care protocol.

  3. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  4. Induced chorioretinal venous anastomosis in experimental retinal branch vein occlusion.

    OpenAIRE

    McAllister, I L; Yu, D Y; Vijayasekaran, S; Barry, C; Constable, I

    1992-01-01

    Iatrogenic retinal vein to choroidal vein anastomoses were created using laser photocoagulation in six of seven dog eyes in which a partial branch retinal vein occlusion had previously been created photochemically. A similar attempt to create an anastomosis was made in six control eyes in which no branch vein occlusion was present. In the eyes in which a branch retinal vein had been created, a venous chorioretinal anastomosis appeared to be present by 3 to 6 weeks. In three control eyes simil...

  5. Central retinal vein occlusion with cilioretinal infarction from branch flow exclusion and choroidal arterial steal.

    Science.gov (United States)

    McLeod, David

    2009-01-01

    The first definitive study of retinal vein occlusion complicated by infarction within the territory of one or more cilioretinal arteries was published in 1976. Many individual cases and further case series have been reported in the interim, but the nature of the interrelationship is still under debate. A review was undertaken of the relevant clinical and fundus fluorescein angiographic characteristics of this combined retinal vascular disorder together with the pathophysiological mechanisms currently presented in the literature to explain their association. Scientific publications up to 2008 were evaluated by one of the authors of the original report. There are broad similarities between publications in their descriptions of the clinical features, but significant differences of detail and interpretation are also evident. Most of the mechanisms so far proposed to account for cilioretinal infarction after central or hemisphere retinal vein occlusion do not withstand critical scrutiny. Two related hypotheses are expounded that appear to satisfactorily elucidate this interrelationship -- branch flow exclusion and branch flow diversion (otherwise termed "choroidal arterial steal"). In eyes with a cilioretinal supply, the probability that cilioretinal infarction will complicate retinal vein occlusion increases with increasing severity of venous obstruction and the more distally the cilioretinal artery arises from the posterior ciliary arterial tree. A distal branch point also facilitates observation of dye front reciprocation within the artery. Indicators of the degree of venous obstruction that may be necessary to instigate cilioretinal infarction include very prolonged dye transit times in the central retinal circulation, exaggerated venous cyanosis and tortuosity, perivenous cotton-wool sentinels, and macular perivenular whitening.

  6. Dural sinus thrombosis - A rare manifestation of internal jugular venous occlusion

    Directory of Open Access Journals (Sweden)

    Pooja Binnani

    2012-01-01

    Full Text Available The dural sinus thrombosis is an uncommon complication of a commonly done procedure of central venous catheterisation. We present a case of massive hemorrhagic venous infarct with gross cerebral edema due to dural sinus thrombosis along with right internal jugular vein thrombus. A 21-year-old male patient presented to the emergency department with fever and swelling of the right neck four days following discharge after his prior hospitalization two weeks ago for acute renal failure due to severe gastroenteritis, when he underwent hemodialysis through right internal jugular access. On presentation, he was conscious, with swelling on right side of the neck, which was diagnosed as right internal jugular vein occlusion. However, he rapidly dete-riorated and developed signs of raised intracranial pressure despite being on treatment with heparin. He was diagnosed as having massive hemorrhagic cerebral venous infarct with gross cerebral edema complicated with shift of the ventricles to the left due to dural sinus thrombosis. Despite emergency decompressive craniotomy, he succumbed in the next two days due to coning. Asymptomatic catheter-related thrombosis is frequent in the intensive care units, but major complications like retrograde extension into dural sinus causing thrombosis is rare. A high index of suspicion is required to diagnose this major catastrophe for an early and meaningful intervention.

  7. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  8. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  9. Case Report of Optic Disc Drusen with Simultaneous Peripapillary Subretinal Hemorrhage and Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    David Zhiwei Law

    2014-01-01

    Full Text Available A 52-year-old Chinese gentleman presented with right eye floaters and photopsia over one week. His visual acuities were 20/20 bilaterally. Posterior segment examination showed a right eye swollen optic disc and central retinal vein occlusion (CRVO associated with an area of subretinal hemorrhage adjacent to the optic disc. Fundus fluorescein (FA and indocyanine green angiographies (ICGA of the right eye did not demonstrate choroidal neovascularization (CNV, polypoidal choroidal vasculopathy (PCV, or retinal ischemia. Ultrasound B-scan revealed optic disc drusen (ODD. In view of good vision and absence of CNV, he was managed conservatively with spontaneous resolution after two months. Commonly, ODD may directly compress and mechanically rupture subretinal vessels at the optic disc, resulting in peripapillary subretinal hemorrhage, as was likely the case in our patient. Mechanical impairment of peripapillary circulation also results in retinal ischemia and may trigger the development of choroidal neovascularization (CNV and/or polypoidal choroidal vasculopathy (PCV, leading to subretinal haemorrhage. Compromise in central venous outflow with increased retinal central venous pressure from the direct mechanical effects of enlarging ODD results in central retinal vein occlusion (CRVO. Patients with subretinal hemorrhage and CRVO from ODD should be monitored closely for the development of potentially sight-threatening complications.

  10. Central Venous Access

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Warakaulle, Dinuke R.; Uberoi, Raman

    2007-01-01

    Central venous access plays an important role in the management of an ever-increasing population of patients ranging from those that are critically ill to patients with difficult clinical access. Interventional radiologists are key in delivering this service and should be familiar with the wide range of techniques and catheters now available to them. A comprehensive description of these catheters with regard to indications, technical aspects of catheterization, success rates, and associated early and late complications, as well as a review of various published guidelines on central venous catheter insertion are given in this article

  11. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  12. MRI and MRV in differentiation of posterior reversible encephalopathy syndrome and venous occlusion in patients with eclampsia or pre-eclampsia

    International Nuclear Information System (INIS)

    Xia Shuang; Liu Qingxian; Qi Ji

    2009-01-01

    Objective: To evaluate the role of MRV and MRI in the diagnosis of posterior encephalopathy syndrome (PRES) and venous sinus occlusion in patients with eclampsia or pre-eclampsia. Methods: We respectively studied the clinical and imaging data of 27 pre-eclampsia or eclampsia patients who occurred epilepsy, headache, and vision deficient during pregnancy or post partum. All patients underwent MRI and MRV examinations. The imaging protocol included coronal, sagittal, and axial T 1 WI, T 2 WI, FLAIR, DWI, and MRV. Results: 14 patients showed evidence of venous occlusion. Among them, 3 occurred in cortical vein, 4 in superior sagittal sinus, 2 in transverse sinus, l in sigmoid sinus, 2 in deep vein system, 3 in jugular vein, and 2 with complete sinus occlusion. Brain edema distributed in the corresponding area of occlusive sinus and 2 cases combined with secondary hemorrhage. 13 patients suffered from hypertensive encephalopathy. All of the lesions involved arcuate fibre in the bilateral parietal lobe (10 cases), right parietal lobe (2 cases), bilateral occipital lobe (7 cases), bilateral frontal lobe (6 cases), right frontal lobe (3 cases), bilateral temporal lobe (4 cases), left temporo-occipital lobe (1 case), splenium of corpus callosum (1 case), bilateral basal ganglia (2 cases), right basal ganglia (1 case), left centrum semiovale (1 case), and bilateral cerebellar hemisphere (1 case). Both of the lesions of PRES and venous occlusion showed hyperintensity on FLAIR and T 2 WI images, isointensity on DWI and hyperintensity on ADC, indicating vasogenic edema. Decreased lesion extent or completely disappeared was identified in 12 patients on follow-up scans. Conclusion: Lesions of PRES are usually located in the parietal and occipital lobes, especially in white matter. The lesion of venous occlusion usually occurs in the area of corresponding occlusive sinus. The MRV has an important value in diagnosis of PRES and venous sinus occlusion. (authors)

  13. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    Science.gov (United States)

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  15. Full-Thickness Retinochoroidal Incision in the Management of Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    2015-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes in patients with central retinal vein occlusion (CRVO treated with full-thickness retinochoroidal incisions and to compare whether there is difference in treatment response in ischemic and nonischemic CRVO. Methods. Retrospective study of patients of CRVO receiving full-thickness retinochoroidal incisions in Changhua Christian Hospital. Fluorescein angiography (FA, slit-lamp biomicroscopy, indirect funduscopy, best corrected visual acuity, and central macular thickness (CMT measured by optical coherence tomography were performed pre- and postoperatively. Patients were divided into an ischemic and nonischemic group according to the findings of FA. Patients were followed up for at least 1 year. Results. Twenty-eight eyes (14 ischemic and 14 nonischemic CRVO were included. Functional retinochoroidal venous anastomosis (RCVA was achieved in 48 of the 65 retinochoroidal incisions (73.8%. Central macular thickness (CMT and retinal hemorrhage decreased significantly after the surgery. Significant visual gain was observed postoperatively in the nonischemic group, but not in the ischemic group. Postoperative complications included vitreous hemorrhage (17.8%, neovascular glaucoma (7.1%, and preretinal fibrovasular membrane (10.7%, all of which were in the ischemic group. Conclusions. RCVA formation induced by retinochoroidal incisions could improve venous flow, and decrease CMT and retinal hemorrhage. However, only eyes with nonischemic CRVO showed visual improvement.

  16. Radiation Retinopathy Associated with Central Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    Yan; Liu; FengWen

    2007-01-01

    Purpose: To report a case of radiation retinopathy associated with central retinal vein occlusion.Methods: The clinical features and fundus fluorescein angiography of this case were analyzed.Results: The patient had been treated with radiotherapy for her nasopharyngeal carcinoma, and presented with sudden visual loss in the left eye. The funduscopic examination and fluorescein angiography showed the features of radiation retinopathy in both eyes, and central retinal vein occlusion in the left eye.Conclusions: Radiation retinopathy can be associated with central retinal vein occlusion in the same eye, and it seems that the endothelial cell loss caused by radiation retinopathy may lead to retinal vein occlusion.

  17. Treatment of High-Flow Vascular Malformations by Venous Embolization Aided by Flow Occlusion Techniques

    International Nuclear Information System (INIS)

    Jackson, James E.; Mansfield, Averil O.; Allison, David J.

    1996-01-01

    Purpose: Transvenous embolization techniques may be helpful as alternatives to the arterial route when treating high-flow vascular malformations. We present our experience using these techniques in four patients. Methods: In one patient the venous portion of the arteriovenous malformation (AVM) was punctured directly; in the other three patients it was catheterized via a retrograde venous approach. Flow occlusion techniques were utilized in all patients during embolization, which was performed with absolute alcohol or N-butyl-2-cyanoacrylate.Results: Excellent clinical and angiographic results were obtained, with obliteration of arteriovenous shunting in all patients. There were no complications.Conclusion: The embolization of certain AVMs using a venous approach is a safe and effective treatment

  18. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  19. [The unnecessary application of central venous catheterization in surgical patients].

    Science.gov (United States)

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  20. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  1. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...... (28-36) (median and range) to 34 (30-40) Ohm, mean arterial pressure (MAP) from 79 (70-88) to 86 (80-99) mmHg, heart rate (HR) from 67 (56-71) to 99 (78-119) beats min-1 (p ....05) but thereafter remained stable. In contrast, central venous oxygen saturation showed a linear decrease with time from 0.75 (0.69-0.78) at rest to 0.60 (0.49-0.67) (p measurement of central venous oxygen saturation...

  2. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  3. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    Science.gov (United States)

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  4. Central venous stenosis among hemodialysis patients is often not associated with previous central venous catheters.

    Science.gov (United States)

    Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji

    2011-01-01

    It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.

  5. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. Pediatric central venous access devices: nursing interventions

    Directory of Open Access Journals (Sweden)

    Duffy EA

    2017-05-01

    Full Text Available Elizabeth A Duffy, Kathryn N Nelson Department of Health Behavior and Biological Sciences, The University of Michigan School of Nursing, Ann Arbor, MI, USA Abstract: A central venous catheter (CVC is an indwelling catheter that provides permanent or temporary stable venous access for both acute and chronically ill pediatric patients. These catheters provide stable venous access that can be used for a variety of medical purposes including drawing blood, hemodynamic monitoring, infusion of intravenous medications, infusion of intravenous fluids, chemotherapy, blood products, and parenteral nutrition. Each day, nurses access and care for CVCs in infants, children, and adolescents; the precision of this care can prevent life-threatening complications. The purpose of this review and the case study is to highlight the importance and components of evidence-based nursing practice in pediatric CVC care. A historical perspective of CVC care is provided in conjunction with current national initiatives to improve patient outcomes for children with CVCs. Infection prevention, clinical practice guidelines, quality improvement, and evidence-based care bundles are discussed. Keywords: pediatric nursing, central venous catheters, central line-associated bloodstream infection, care bundles, pediatric case study 

  7. Massive hydrothorax with malpositioned central venous catheter – Ultrasound detection

    Directory of Open Access Journals (Sweden)

    Neha Hasija

    2016-04-01

    Full Text Available Radioimaging is the gold standard for confirmation of the position of central venous catheter as well as its related complications. Use of ultrasound has been proven in guiding central venous cannulations, and it can also be used in detecting related complications. We report a case of a 2 year old child with hydrothorax causing desaturation due to malpositioned central venous catheter diagnosed by ultrasound in the delay for getting a radiograph.

  8. Hemi-central retinal artery occlusion in young adults

    Directory of Open Access Journals (Sweden)

    Rishi Pukhraj

    2010-01-01

    Full Text Available Amongst the clinical presentations of retinal artery occlusion, hemi-central retinal artery occlusion (Hemi-CRAO is rarely described. This case series of four adults aged between 22 and 36 years attempts to describe the clinical profile, etiology and management of Hemi-CRAO. Case 1 had an artificial mitral valve implant. Polycythemia and malignant hypertension were noted in Case 2. The third patient had Leiden mutation while the fourth patient had Eisenmenger′s syndrome. Clinical examination and fundus fluorescein angiography revealed a bifurcated central retinal artery at emergence from the optic nerve head, in all cases. Color Doppler examination of the central retinal artery confirmed branching of the artery behind the lamina cribrosa. It is hypothesized that bifurcation of central retinal artery behind the lamina cribrosa may predispose these hemi-trunks to develop an acute occlusion if associated with underlying risk factors. The prognosis depends upon arterial recanalisation and etiology of the thromboembolic event.

  9. Bilateral retinal vein occlusion and rubeosis irides: lessons to learn.

    Science.gov (United States)

    Md Noh, Umi Kalthum; Ahem, Amin; Mustapha, Mushawiahti

    2013-01-01

    Uncontrolled hypertension is well- known to give rise to systemic complications involving multiple central organs. Artherosclerosis leads to damage of the retinal vessels wall, contributing to venous stasis, thrombosis and finally, occlusion. Retinal vein occlusions compromise vision through development of ischaemic maculopathy, macular oedema, and rubeotic glaucoma. Laser photocoagulation remains the definitive treatment for ischaemic vein occlusion with secondary neovascularization. Timely treatment with anti- vascular endothelial growth factor prevents development of rubeotic glaucoma. We hereby report an unusual case of bilateral retinal vein occlusion complicated by rubeosis irides, which was successfully managed to improve vision and prevent rubeotic glaucoma.

  10. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  11. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    Science.gov (United States)

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  12. Evidence for an enduring ischaemic penumbra following central retinal artery occlusion, with implications for fibrinolytic therapy.

    Science.gov (United States)

    McLeod, David; Beatty, Stephen

    2015-11-01

    The rationale behind hyperacute fibrinolytic therapy for cerebral and retinal arterial occlusion is to rescue ischaemic cells from irreversible damage through timely restitution of tissue perfusion. In cerebral stroke, an anoxic tissue compartment (the "infarct core") is surrounded by a hypoxic compartment (the "ischaemic penumbra"). The latter comprises electrically-silent neurons that undergo delayed apoptotic cell death within 1-6 h unless salvaged by arterial recanalisation. Establishment of an equivalent hypoxic compartment within the inner retina following central retinal artery occlusion (CRAO) isn't widely acknowledged. During experimental CRAO, electroretinography reveals 3 oxygenation-based tissue compartments (anoxic, hypoxic and normoxic) that contribute 32%, 27% and 41% respectively to the pre-occlusion b-wave amplitude. Thus, once the anoxia survival time (≈2 h) expires, the contribution from the infarcted posterior retina is irreversibly extinguished, but electrical activity continues in the normoxic periphery. Inbetween these compartments, an annular hypoxic zone (the "penumbra obscura") endures in a structurally-intact but functionally-impaired state until retinal reperfusion allows rapid recovery from electrical silence. Clinically, residual circulation of sufficient volume flow rate generates the heterogeneous fundus picture of "partial" CRAO. Persistent retinal venous hypoxaemia signifies maximal extraction of oxygen by an enduring "polar penumbra" that permeates or largely replaces the infarct core. On retinal reperfusion some days later, the retinal venous oxygen saturation reverts to normal and vision improves. Thus, penumbral inner retina, marginally oxygenated by the choroid or by residual circulation, isn't at risk of delayed apoptotic infarction (unlike hypoxic cerebral cortex). Emergency fibrinolytic intervention is inappropriate, therefore, once the duration of CRAO exceeds 2 h. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    International Nuclear Information System (INIS)

    Nicholson, Tony; Ettles, Duncan; Robinson, Graham

    2004-01-01

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred with carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device

  14. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    Science.gov (United States)

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  15. Acute Central Retinal Vein Occlusion Secondary to Reactive Thrombocytosis after Splenectomy

    Directory of Open Access Journals (Sweden)

    Nursen Oncel Acir

    2014-01-01

    Full Text Available The diagnosis and treatment of central retinal vein occlusion was reported in a young patient. Central retinal vein occlusion was probably related to secondary to reactive thrombocytosis after splenectomy. The patient was treated with steroids for papilledema and administered coumadin and aspirin. The symptoms resolved, and the findings returned to normal within three weeks. Current paper emphasizes that, besides other well-known thrombotic events, reactive thrombocytosis after splenectomy may cause central retinal vein occlusion, which may be the principal symptom of this risky complication. Thus, it can be concluded that followup for thrombocytosis and antithrombotic treatment, when necessary, are essential for these cases.

  16. Cytomegalovirus retinitis after central retinal vein occlusion in a patient on systemic immunosuppression: does venooclusive disease predispose to cytomegalovirus retinitis in patients already at risk?

    Directory of Open Access Journals (Sweden)

    Welling JD

    2012-04-01

    Full Text Available John D Welling, Ahmad B Tarabishy, John ChristoforidisDepartment of Ophthalmology, Havener Eye Institute, Ohio State University, Columbus, OH, USAAbstract: Cytomegalovirus (CMV retinitis remains the most common opportunistic ocular infection in immunocompromised patients. Patients with immunocompromising diseases, such as acquired immunodeficiency syndrome, inherited immunodeficiency states, malignancies, and those on systemic immunosuppressive therapy, are known to be at risk. Recently, it has been suggested that patients undergoing intravitreal injection of immunosuppressive agents may also be predisposed. One previous case report speculated that there may be an additional risk for CMV retinitis in acquired immunodeficiency syndrome patients with venoocclusive disease. This case study presents a case of CMV retinitis following central retinal vein occlusion in a patient on systemic immunosuppressants.Keywords: cytomegalovirus retinitis, central retinal vein occlusion, immunosuppression, solid organ transplant, venous stasis, risk factor

  17. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    Science.gov (United States)

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  18. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    Science.gov (United States)

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  19. Total venous inflow occlusion and pericardial auto-graft reconstruction for right atrial hemangiosarcoma resection in a dog

    Science.gov (United States)

    Verbeke, Fei; Binst, Dominique; Stegen, Ludo; Waelbers, Tim; de Rooster, Hilde; Van Goethem, Bart

    2012-01-01

    A sizeable right atrial hemangiosarcoma in a 6-year-old Bordeaux dog, World Health Organization (WHO) stage 2, was excised using total venous inflow occlusion. The defect was restored with a non-vascularized pericardial auto-graft. The dog had a disease-free interval of 7 mo. The dog was euthanized 9 months later, at which time there were distant metastases but no indication of local recurrence. PMID:23543933

  20. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  1. Central Retinal Vein Occlusion AssociatedWith Sildenafil (Viagra

    Directory of Open Access Journals (Sweden)

    H C Obiudu

    2010-01-01

    Conclusion - Central retinal vein occlusion is a possible adverse effect of sildenafil use. Physicians should be vigilant while prescribing thismedication and avoid its use in patients with elevated intraocular pressure

  2. Pinch-off syndrome: transection of implantable central venous access device

    OpenAIRE

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-01-01

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take che...

  3. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest......Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position...

  4. THE SIGNIFICANCE OF PATTERN ERG IN CENTRAL VEIN OCCLUSION

    Directory of Open Access Journals (Sweden)

    Saša Novak

    2004-12-01

    Full Text Available Pattern electroretinogram (PERG findings were analysed in 30 patients with central retinal vein occlusion. Latency and amplitude values of PERG waves were compared with the results obtained in 30 healthy individuals after sample randomisation. In 15 cases with „hemorrhagic type” occlusion of the central retinal vein significantly reduced N1-P1 wave amplitude was noted (0,369 mV, related to „exudative“ disease type (0,557 mV, as well as to the control group of examines (0,782 mV. PERG was described as the sensitive method and important indicator in damage assessment, ie. ischemia in the ganglional cell layer in central retinal vein occlusion. Ischemia increases anoxia, which influences not only the axons but also the enzymatic and transport processes within the cell bodies, dendrites, axons and axonal terminals. Slowing down of the fast phase of axoplasmatic transport in the axons in ischemic damage blocked transmission impulses which could be evident through different degrees of PERG wave amplitude reduction. With this method the patients can be selected in whom due to severe retinal ischemia there is the risk of neovascular glaucomma and maculopathy, which is the absolute indication for panlaser-photocoagulation.

  5. Combined central retinal artery and vein occlusion in Churg-Strauss syndrome

    DEFF Research Database (Denmark)

    Hamann, Steffen; Johansen, Sven; Hamann, Steffen Ellitsgaard

    2006-01-01

    PURPOSE: To describe a rare case of Churg-Strauss syndrome presenting with severe visual loss due to a combined central retinal vein and artery occlusion. METHODS: A 42-year old man with a medical history of asthma and blood hypereosinophilia developed a sudden loss of vision in his right eye. We...... and dilated and tortuous veins. The diagnosis was confirmed by a fluorescein angiogram showing absence of retinal filling and normal choroidal filling. Churg-Strauss syndrome was diagnosed based on the necessary presence of four of six criteria for the disease proposed by the American College of Rheumatology...... the vascular occlusion and experienced no visual improvement. CONCLUSION: Combined central retinal artery and vein occlusion can occur in Churg-Strauss syndrome. We suggest that regional vasculitis may be the pathological mechanism underlying the vascular occlusions observed in our case. The condition carries...

  6. [The influence of joining central venous catheter and pressure transducer with T-junctions on central venous pressure].

    Science.gov (United States)

    Cheng, Xiuling; Yang, Wanjie; An, Youzhong; Teng, Hongyun; Zhang, Rumei; Wang, Yumei; Gao, Hailing; Hua, Ning; Song, Yan

    2015-08-01

    To investigate the influence of the number of T-junctions between central venous catheter and pressure transducer on measurement of central venous pressure ( CVP ) in patients. A prospective controlled study was conducted. The patients with CVP monitoring in Department of Critical Care Medicine of the Fifth Center Hospital in Tianjin from February to October in 2014 were enrolled. The patients were divided into three groups according to the number of T-junction between central venous catheter and pressure transducer: without T-junction control group and 1, 2, 3 T-junctions groups. In each patient, corresponding CVP values with different number of T-junctions placed between the central venous catheter and pressure sensors were determined within a certain period, and a square-wave graphic was obtained and preserved on the monitor. The own frequency ( fn ) and the attenuation coefficient ( D ) of the system of pressure measurement were calculated after measurement of the shock wave following a square-wave to obtain the distance between two vibrations and the amplitude of the shock wave. The difference in CVP, fn and D were compared among the groups. A total of 20 cases were enrolled, and 150 groups of data were collected. (1) With the increase in the number of T-junction, CVP showed a tendency of gradual reduction. The CVP of the groups of control and 1, 2, 3 T-junctions was ( 7.00±1.60 ), ( 7.00±3.00 ), ( 5.00±2.00 ), and ( 4.00±1.00 ) mmHg ( 1 mmHg = 0.133 kPa ), respectively. The CVP of 3 T-junctions group was significantly lower than that of the control group ( F = 9.333, P = 0.015 ). (2) With an increase in the number of T-junction, fn showed a tendency of gradual increase. The fn of groups control and 1, 2, 3 T-junctions was ( 12.30±0.79 ), ( 16.00±0.91 ), ( 18.10±1.75 ), ( 20.90±2.69 ) Hz, respectively. The fn of 1, 2, 3 T-junctions group was significantly higher than that of the control group ( F1 = 45.962, F2 = 45.414, F3 = 46.830, all P = 0

  7. Central venous catheterization: comparison between interventional radiological procedure and blind surgical reocedure

    International Nuclear Information System (INIS)

    Song, Won Gyu; Jin, Gong Yong; Han, Young Min; Yu, He Chul

    2002-01-01

    To determine the usefulness and safety of radiological placement of a central venous catheter by prospectively comparing the results of interventional radiology and blind surgery. For placement of a central venous catheter, the blind surgical method was used in 78 cases (77 patients), and the interventional radiological method in 56 cases (54 patients). The male to female ratio was 66:68, and the patients' mean age was 48 (range, 18-80) years. A tunneled central venous catheter was used in 74 cases, and a chemoport in 60. We evaluated the success and duration of the procedures, the number of punctures required, and ensuing complications, comparing the results of the two methods. The success rates of the interventional radiological and the blind surgical procedure were 100% and 94.8%, respectively. The duration of central catheterization was 3-395 (mean, 120) day, that of chemoport was 160.9 days, and that of tunneled central venous catheter was 95.1 days. The mean number of punctures of the subclavian vein was 1.2 of interventional radiology, and 2.1 for blind surgery. The mean duration of the interventional radiology and the blind surgical procedure was, respectively, 30 and 40 minutes. The postprocedure complication rate was 27.6% (37 cases). Early complications occurred in nine cases (6.7%): where interventional radiology was used, there was one case of hematoma, and blind surgery gave rise to hematoma (n=2), pneumothorax (n=2), and early deviation of the catheter (n=4). Late complications occurred in 32 cases (23.9%). Interventional radiology involved infection (n=4), venous thrombosis (n=1), catheter displacement (n=2) and catheter obstruction (n=5), while the blind surgical procedure gave rise to infection (n=5), venous thrombosis (n=3), catheter displacement (n=4) and catheter obstruction (n=8). The success rate of interventional radiological placement of a central venous catheter was high and the complication rate was low. In comparison with the blind

  8. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    International Nuclear Information System (INIS)

    Grabbe, E.; Guthoff, A.; Hamburg Univ.

    1981-01-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations. (orig.) [de

  9. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, E; Guthoff, A

    1981-02-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations.

  10. Central venous catheter-related bloodstream infections in cancer patients

    International Nuclear Information System (INIS)

    Butt, T.; Afzal, R.K.; Ahmad, R.N.; Hussain, I.; Anwar, M.

    2004-01-01

    Objective: To determine the frequency of central venous catheter-related bloodstream infections (CR-BSI) in cancer patients and the antimicrobial susceptibility pattern of the isolates. Subjects and Methods: Cancer patients requiring short or long-term central venous catheterization at the time of admission or thereafter were included. Catheter tips on removal were cultured quantitatively; specimens of blood and pus were cultured qualitatively. Isolates were identified and antimicrobial susceptibility testing was performed by standard techniques. Results: Eighty-nine patients were included in the study. The frequency of CR-BSI was 17%. Out of the 19 organisms isolated, 10 (53%) were Gram-positive cocci, 8 (42%) were Gram-negative rods and 1 (5%) was a fungus. Coagulase negative staphylococci (27%) were the predominant pathogens. Among the staphylococci, 46% of the isolates were methicillin-resistant. All Gram-positive isolates were susceptive to glycopeptides. Gram-negative rods were resistant to most of the commonly used antimicrobial groups. Conclusion: Central venous catheter is an important source of bloodstream infections in cancer patients. Most of the infections are caused by Gram-positive cocci. Rigorous infection control measures and continuous surveillance is required to curb the frequency of these infections. (author)

  11. Is there a link between the structural impact of thoracic outlet and the development of central venous stenosis?

    Science.gov (United States)

    Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji

    2013-01-01

    Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  13. Outflow occlusion for circulatory arrest in dogs "Outfow occlusion" para parada circulatória em cães

    Directory of Open Access Journals (Sweden)

    James N.B.M. de Andrade

    2009-02-01

    Full Text Available The purpose of this study was to evaluate the possibility of producing circulatory arrest by occlusion of the pulmonary trunk as an alternative to the venous inflow occlusion through the left hemithorax. Eight healthy mongrel dogs were divided in two groups. Group I underwent 4 minutes of outflow occlusion and Group II was submitted to 8 minutes of circulatory arrest. Outflow occlusion was performed through left thoracotomy and pericardiotomy by passing a Rumel tourniquet around the pulmonary trunk. Physical examination, electrocardiography, echocardiography, blood gas analyses, hemodynamic, and oxygen transport variables were obtained before and after the procedure. The dogs from Group I did not have any clinical, electrocardiographic, echocardiographic, or hemo-dynamic abnormalities after anesthetic recover. In the Group II, only one dog survived, which had no clinical, electrocardiographic, or echocardiographic abnormalities. In this last dog, just after releasing the occlusion, it was detected increases in the following parameters: heart rate (HR, systolic, diastolic and mean arterial blood pressure (SAP; DAP; MAP, pulmonary artery pressure (PAP, pulmonary wedge pressure (PWP, central venous pressure (CVP, cardiac output (CO, systolic index (SI, cardiac index (CI, left and right ventricular stroke work (LVSW; RVSW, oxygen delivery index (DO2, oxygen consumption index (VO2, and oxygen extraction (O2 ext. Moreover, the oxygen content of arterial and mixed venous blood (CaO2; CvO2, and the arterial and mixed venous partial pressure of oxygen (PaO2; PvO2 were decreased 5 minutes after circulatory arrest. Outflow occlusion is a feasible surgical procedure for period of 4 minutes of circulatory arrest.O objetivo deste estudo foi avaliar a possibilidade de se produzir uma parada circulatória pela oclusão do tronco pulmonar, como alternativa ao "inflow occlusion", pelo hemitórax esquerdo. Oito cães sem raça definida foram divididos em dois

  14. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    Science.gov (United States)

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  15. Reduction in central venous pressure enhances erythropoietin synthesis

    DEFF Research Database (Denmark)

    Montero, D.; Rauber, S.; Gøtze, Jens Peter

    2016-01-01

    AIMS: Erythropoiesis is a tightly controlled biological event, but its regulation under non-hypoxic conditions, however, remains unresolved. We examined whether acute changes in central venous blood pressure (CVP) elicited by whole-body tilting affect erythropoietin (EPO) concentration according...

  16. Systemic treatments for the prevention of venous thrombo-embolic events in paediatric cancer patients with tunnelled central venous catheters

    NARCIS (Netherlands)

    Schoot, Reineke A.; Kremer, Leontien C. M.; van de Wetering, Marianne D.; van Ommen, Cornelia H.

    2013-01-01

    Venous thrombo-embolic events (VTEs) occur in 2.2% to 14% of paediatric cancer patients and cause significant morbidity and mortality. The malignant disease itself, the cancer treatment and the presence of central venous catheters (CVCs) increase the risk of VTE. The primary objective of this review

  17. Cerebral sino-venous thrombosis

    International Nuclear Information System (INIS)

    Sayama, Ichiro; Kobayashi, Tsunesaburo; Nakajima, Kenji

    1982-01-01

    Three cases of cerebral sino-venous thrombosis were reported. Repeated CT findings were studied and discussed on account of the treatments for those pathologic conditions. Those of studied cases are; a 22-year-old postpartum woman, a 42-year-old woman with irregular vaginal bleeding, and a 26-year-old man with severe reactive emesis after drinking alcohol. They were treated conservatively. Case 1 died in its acute stage. In the remaining ones, each had an uneventful recovery. CT scan findings of them manifested their exact clinical conditions. These findings were devided into two categories, one was direct signs expressed sino-venous occlusion, the other was indirect signs which appeared as a result of these occlusion. Direct signs cannot always get in every cases with sino-venous occlusion, but as for indirect signs, we can get various changes corresponding to the time taken CT photoes, and they are useful to decide appropriate treatments at that time. Considering suitable treatments for this disease, it is necessary to select most suitable ones according to their pathologic conditions, which may be precisely drawn with CT scans. (J.P.N.)

  18. Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

    Science.gov (United States)

    Ainsworth, S B; Clerihew, L; McGuire, W

    2007-07-18

    Parenteral nutrition for neonates may be delivered via a short peripheral cannula or a central venous catheter. The latter may either be inserted via the umbilicus or percutaneously. Because of the complications associated with umbilical venous catheter use, many neonatal units prefer to use percutaneously inserted catheters following the initial stabilisation period. The method of parenteral nutrition delivery may affect nutrient input and consequently growth and development. Although potentially more difficult to place, percutaneous central venous catheters may be more stable than peripheral cannulae, and need less frequent replacement. These delivery methods may also be associated with different risks of adverse events, including acquired systemic infection and extravasation injury. To determine the effect of infusion via a percutaneous central venous catheter versus a peripheral cannula on nutrient input, growth and development, and complications including systemic infection, or extravasation injuries in newborn infants who require parenteral nutrition. The standard search strategy of the Cochrane Neonatal Review Group was used. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1, 2007), MEDLINE (1966 - February 2007), EMBASE (1980 - February 2007), conference proceedings, and previous reviews. Randomised controlled trials that compared the effect of delivering parenteral nutrition via a percutaneous central venous catheter versus a peripheral cannulae in neonates. Data were extracted the data using the standard methods of the Cochrane Neonatal Review Group, with separate evaluation of trial quality and data extraction by each author, and synthesis of data using relative risk, risk difference and mean difference. Four trials eligible for inclusion were found. These trials recruited a total of 368 infants and reported a number of different outcomes. One study showed that the use of a percutaneous

  19. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    Science.gov (United States)

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  20. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  1. Oral contraceptive pills: A risk factor for retinal vascular occlusion in in-vitro fertilization patients

    Directory of Open Access Journals (Sweden)

    Rohina S Aggarwal

    2013-01-01

    Full Text Available Retinal vascular occlusion is the most common cause of retinopathy leading to severe visual loss in all age groups. Central retinal vein occlusion (CRVO is usually seen in older age group and is often associated with systemic vascular diseases. Although the exact cause and effect relationship has not been proven, central retinal vein occlusion has been associated with various systemic pathological conditions, hence a direct review of systems toward the various systemic and local factors predisposing the central retinal vein occlusion is advocated. We describe the development of central retinal venous occlusion with associated cystoid macular edema (CME in two healthy infertile women who were recruited for in vitro fertilization cycle for infertility. Predisposing risk factors associated with central retinal vein occlusion are obesity, sedentary life style, smoking, and some systemic diseases such as hyperlipidemia, hypertension, associated autoimmune disorders e.g., antiphospholipid antibody syndrome, lupus, diabetes mellitus, cardiovascular disorders, bleeding or clotting disorders, vasculitis, closed-head trauma, alcohol consumption, primary open-angle glaucoma or angle-closure glaucoma.In our patients, they were ruled out afterdoing allpertaining investigations. The cases were managed with further avoidance of oral contraceptives and intra-vitreal injections of Bevacizumab (Avastin, an anti-vascular endothelial growth factor (anti-VEGF drug and Triamcinolone acetonide (a long acting synthetic steroid. Hence, even if no systemic diseases are detected. Physical examinations are recommended periodically for young women on oral contraceptive pills.

  2. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  3. Serious Complication of Central Venous Catheterization Due to Hemothorax: Hemothorax

    Directory of Open Access Journals (Sweden)

    Ümmügülsüm Gaygısız

    2017-12-01

    Full Text Available Central venous catheterization may cause life-threatening complications including pneumothorax and hemothorax. We report a case of multiple trauma complicated with an incidence of hemothorax due to a misplaced central venous catheter. Firstly, the tip of the guide-wire was ruptured in subcutaneous tissue and, secondly, the catheter came out of the vessel and caused hemothorax. During left subclavian catheterization, in this 47-years-old male patient, we could not advance the guide wire forward easily in the first attempt and tried to draw it back. In the second attempt, we inserted a new catheter without any difficulty. The blood gas analyses through the catheter for verification of location revealed its venous nature. After the catheterization, 500 mL hemorrhagic fluid was drained through the ipsilateral chest tube. Control chest X-ray showed that the catheter was in the left hemithorax and a piece of the guide wire was present below the left clavicle. Thorax computerized tomography showed that the catheter entered the thoracic cavity and extended to the paramediastinal region. An emergency surgery was performed to remove the piece of the guide wire and the catheter extending out of the vessel. A common method to check the intravenous insertion of a central catheter into a vein is to verify that the easily drawn blood has the nature of venous blood. This method, however, does not exclude the extravascular placement of the catheter in the presence of ipsilateral hemothorax.

  4. Reduction mammoplasty as a treatment for symptomatic central venous stenosis

    Directory of Open Access Journals (Sweden)

    Denise Seok Fun Fok

    2018-03-01

    Full Text Available Central venous stenosis is a rare cause of unilateral breast edema occurring in hemodialysis patients that needs to be differentiated from other differential diagnoses, including, but not limited to, inflammatory breast carcinoma, mastitis, lymphedema, and congestive heart failure. All reports of similar cases in the available literature have described improvement or resolution of the edema after treatment. Herein, we report and discuss the pathophysiology of breast edema formation in a patient who presented with massive left-sided breast edema 7 years after being diagnosed with central venous stenosis. Medical and minimally invasive therapy had not been successful, so she underwent reduction mammoplasty to relieve the symptoms.

  5. Pinch-off syndrome: transection of implantable central venous access device.

    Science.gov (United States)

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-11-30

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.

  6. In the absence of a central venous catheter, risk of venous thromboembolism is low in critically injured children, adolescents, and young adults: evidence from the National Trauma Data Bank.

    Science.gov (United States)

    O'Brien, Sarah H; Candrilli, Sean D

    2011-05-01

    To describe the incidence and risk factors of venous thromboembolism in a large sample of critical care pediatric, adolescent, and young adult trauma patients. The National Trauma Data Bank-the largest and most complete aggregation of trauma registry data in the United States. Seven hundred eighty-four level I to level IV trauma centers. Patients ≤ 21 yrs of age who spent at least 1 day in a critical care unit during a trauma admission between 2001 and 2005. To characterize differences between patients with and without venous thromboembolism, we extracted variables regarding patient demographics, injury pattern and severity, procedures, total length of stay, and intensive care unit and ventilator days. Odds ratios for predictors of venous thromboembolism were estimated with a logistic regression model. Among the 135,032 critical care patients analyzed, venous thromboembolism was uncommon (6 per 1,000 discharges). Placement of a central venous catheter was a significant predictor of venous thromboembolism (odds ratio = 2.24; p central venous catheter were of even greater magnitude, particularly in adolescents and young adults. The risk of venous thromboembolism in critical care patients without a central venous catheter was central venous access.

  7. Human cerebral venous outflow pathway depends on posture and central venous pressure

    Science.gov (United States)

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  8. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges

    International Nuclear Information System (INIS)

    Abay, T Y; Kyriacou, P A

    2016-01-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG. (paper)

  9. Brain venous pathologies: MRI findings

    International Nuclear Information System (INIS)

    Salvatico, Rosana; Gonzalez, Alejandro; Yanez, Paulina; Romero, Carlos; Trejo, Mariano; Lambre, Hector

    2006-01-01

    Purpose: To describe MRI findings of the different brain venous pathologies. Material and Methods: Between January 2002 and March 2004, 18 patients were studied 10 males and 8 females between 6 and 63 years old; with different brain venous pathologies. In all cases brain MRI were performed including morphological sequences with and without gadolinium injection and angiographic venous sequences. Results: 10 venous occlusions were found, 6 venous angiomas, and 2 presented varices secondary to arteriovenous dural fistula. Conclusion: Brain venous pathologies can appear in many different clinical contexts, with different prognosis and treatment. In all the cases brain MRI was the best imaging study to disclose typical morphologic abnormalities. (author) [es

  10. Bilateral Pneumothoraces Following Central Venous Cannulation

    OpenAIRE

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right ...

  11. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  12. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  13. Penile venous surgery for treating erectile dysfunction: Past, present, and future perspectives with regard to new insights in venous anatomy

    Directory of Open Access Journals (Sweden)

    Cheng-Hsing Hsieh

    2016-06-01

    Full Text Available In the physiologic model of normal erectile function, a healthy veno-occlusive mechanism is essential to initiate and maintain a rigid erection. The surgical treatment of patients with venous leakage, which is synonymous with corporoveno-occlusive dysfunction (CVOD, was based on the decreased venous outflow during the erection process. The initial reports of short-term results were promising, but the long-term benefits of penile venous ligation surgery were limited. Most clinical guideline panels concluded that surgeries performed in an attempt to limit the venous outflow of the penis were not recommended. Consequently, this surgery was nearly abandoned in most medical societies worldwide. These unfavorable postoperative outcomes seemed attributable to the indispensable usage of electrocautery and insufficient venous management, based on conventional penile venous anatomy. Advances in better understanding of human penile venous anatomy has enabled the development of refined penile venous stripping surgery. The thorough stripping surgery is an even more radical procedure, which is an even more radical procedure, and seems to be a viable option for the treatment of CVOD, however, there is still a need for further study with well-defined diagnostic criteria, and standardized patient and partner outcome assessment.

  14. Cerebral Perfusion Long Term after Therapeutic Occlusion of the Internal Carotid Artery in Patients Who Tolerated Angiographic Balloon Test Occlusion

    NARCIS (Netherlands)

    Gevers, S.; Heijtel, D.; Ferns, S. P.; van Ooij, P.; van Rooij, W. J.; van Osch, M. J.; van den Berg, R.; Nederveen, A. J.; Majoie, C. B.

    2012-01-01

    BACKGROUND AND PURPOSE: Therapeutic carotid occlusion is an established technique for treatment of large and giant aneurysms of the (CA, in patients with synchronous venous filling on angiography during BTO. Concern remains that hemodynamic alterations after permanent occlusion will predispose the

  15. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    Science.gov (United States)

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  16. Deep venous thrombophlebitis following aortoiliac reconstructive surgery

    International Nuclear Information System (INIS)

    Reilly, M.K.; McCabe, C.J.; Abbott, W.M.; Brewster, D.C.; Moncure, A.C.; Reidy, N.C.; Darling, R.C.

    1982-01-01

    One hundred patients undergoing elective aortic surgery were scanned prospectively for development of deep venous thrombosis (DVT). The incidence of DVT in this population was 13%. Eleven patients showed only calf vein thrombosis on venography, whereas two had occlusive iliofemoral thrombus. The correlation between venous Doppler ultrasound and venography was 80%. More importantly, Doppler examination correctly identified both patients with occlusive thrombus. Fibrinogen scanning was associated with a false-positive rate of 31%. Only one patient suffered a nonfatal pulmonary embolus. Fibrinogen scanning has an unacceptably high false-positive rate; however, Doppler ultrasound will identify significant occlusive thrombus without a high false-positive rate. The low incidence of pulmonary emboli does not warrant such definitive measures as prophylactic vena caval interruption

  17. Imaging Characteristics of Venous Parenchymal Abnormalities.

    Science.gov (United States)

    Arnoux, Audrey; Triquenot-Bagan, Aude; Andriuta, Daniela; Wallon, David; Guegan-Massardier, Evelyne; Leclercq, Claire; Martinaud, Olivier; Castier-Amouyel, Mélody; Godefroy, Olivier; Bugnicourt, Jean-Marc

    2017-12-01

    There are few published data on the patterns of parenchymal imaging abnormalities in a context of cerebral venous thrombosis (CVT). The objectives of the present study were to describe the patterns of parenchymal lesions associated with CVT and to determine the lesion sites. We included 44 consecutively hospitalized patients with CVT and parenchymal lesions on magnetic resonance imaging. The diagnosis of CVT had been confirmed by magnetic resonance imaging/magnetic resonance venography. Magnetic resonance imaging patterns for CVT were retrospectively analyzed with regard to the lesion's type, shape, and site. The most frequent stroke subtype was hemorrhagic ischemia (in 56.8% of cases), followed by intracerebral hematoma (in 22.72% of cases) and nonhemorrhagic ischemia (in 20.45% of cases). Although there were no significant differences between these 3 groups with regard to the clinical and radiological characteristics, we observed a nonsignificant trend ( P =0.08) toward a shorter time interval between hospital admission and magnetic resonance imaging for nonhemorrhagic stroke. The CVT parenchymal abnormalities were centered on 6 main foci and were related to the site of venous occlusion: (1) the inferior parietal lobule (n=20; 44.5%), associated mainly with occlusion of the transverse sinus (n=10) or pure cortical veins (n=10); (2) the inferior and posterior temporal regions (n=10; 22.75%), associated mainly with occlusion of the transverse sinus (n=9); (3) the parasagittal frontal region (n=6; 13.6%), associated mainly with occlusion of the superior sagittal sinus (n=4) or the transverse sinus (n=4); (4) the thalamus (n=5; 11.3%) associated with occlusion of the straight sinus (n=5); (5) the cerebellar hemisphere (n=2; 4.5%), associated in both cases with occlusion of the transverse sinus; and (6) the deep hemispheric regions (n=3; 6.8%), associated with occlusion of the superior sagittal sinus in all cases. Parenchymal lesions caused by CVT display specific

  18. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  19. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    Science.gov (United States)

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  20. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  1. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  2. Predictors of Venous Thromboembolic Events Associated with Central Venous Port Insertion in Cancer Patients

    Directory of Open Access Journals (Sweden)

    Christine Hohl Moinat

    2014-01-01

    Full Text Available Insertion of central venous port (CVP catheter in the cancer population is associated with increased incidence of venous thromboembolic events (VTE. However, trials have shown limited benefit of antithrombotic treatment to prevent catheter-related venous thrombosis. This prospective observational cohort study was designed to assess the incidence of VTE closely related to CVP implantation in patients with cancer and undergoing chemotherapy, and to identify a high risk subgroup of patients. Between February 2006 and December 2011, 1097 consecutive cancer patients with first CVP implantation were included. Catheter-related VTE were defined as deep venous thrombosis in the arm, with or without pulmonary embolism (PE, or isolated PE. The incidence of CVP-associated VTE was 5.9% (IC95 4.4–7.3% at 3 months, and 11.3% (IC95 9.4–13.2% at 12 months. The incidence of any VTE was 7.6% (IC95 6.0–9.3% at 3 months, and 15.3% (IC95 13.1–17.6% at 12 months. High Khorana risk score and lung cancer were significant predictors of 3 month VTE. In conclusion, this large cohort study of patients with first CVP catheter implantation confirms the high incidence of VTE associated with the CVP implantation and allow identifying high risk patients who may benefit from thromboprophylaxis.

  3. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  4. Altered Venous Function during Long-Duration Spaceflights

    Directory of Open Access Journals (Sweden)

    Jacques-Olivier Fortrat

    2017-09-01

    Full Text Available Aims: Venous adaptation to microgravity, associated with cardiovascular deconditioning, may contribute to orthostatic intolerance following spaceflight. The aim of this study was to analyze the main parameters of venous hemodynamics with long-duration spaceflight.Methods: Venous plethysmography was performed on 24 cosmonauts before, during, and after spaceflights aboard the International Space Station. Venous plethysmography assessed venous filling and emptying functions as well as microvascular filtration, in response to different levels of venous occlusion pressure. Calf volume was assessed using calf circumference measurements.Results: Calf volume decreased during spaceflight from 2.3 ± 0.3 to 1.7 ± 0.2 L (p < 0.001, and recovered after it (2.3 ± 0.3 L. Venous compliance, determined as the relationship between occlusion pressure and the change in venous volume, increased during spaceflight from 0.090 ± 0.005 to 0.120 ± 0.007 (p < 0.01 and recovered 8 days after landing (0.071 ± 0.005, arbitrary units. The index of venous emptying rate decreased during spaceflight from −0.004 ± 0.022 to −0.212 ± 0.033 (p < 0.001, arbitrary units. The index of vascular microfiltration increased during spaceflight from 6.1 ± 1.8 to 10.6 ± 7.9 (p < 0.05, arbitrary units.Conclusion: This study demonstrated that overall venous function is changed during spaceflight. In future, venous function should be considered when developing countermeasures to prevent cardiovascular deconditioning and orthostatic intolerance with long-duration spaceflight.

  5. Malnutrition and bilateral central retinal vein occlusion in a young woman: a case report

    Directory of Open Access Journals (Sweden)

    Taubert Mark

    2008-03-01

    Full Text Available Abstract Introduction Can vitamin B12 and folate deficiency cause central retinal vein occlusion? We conducted a literature search to find out whether nutritional deficiency of vitamin B12 and folate can lead to impaired vision. Case presentation The patient in the article presented in an eye-casualty department in the North East of England with gradual painless visual loss over six weeks. She was found to have bilateral central retinal vein occlusion with significant anaemia and vitamin B12 and folate deficiency. Conclusion Vitamin B12 and folate deficiency can lead to elevated levels of homocysteine. We found a large amount of published data relating central retinal vein occlusion to elevated homocysteine levels, but there was a lack of conclusive evidence for this association Patients should be asked about their dietary history where a thrombotic event is suspected or confirmed.

  6. Ocular neovascularization in eyes with a central retinal artery occlusion or a branch retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Mason lll JO

    2015-06-01

    Full Text Available John O Mason III,1,2 Shyam A Patel,1 Richard M Feist,1,2 Michael A Albert Jr,1,2 Carrie Huisingh,1 Gerald McGwin Jr,1,3 Martin L Thomley1,2 1Department of Ophthalmology, University of Alabama School of Medicine, Birmingham, AL, USA; 2Retina Consultants of Alabama, Callahan Eye Foundation Hospital, Birmingham, AL, USA; 3Department of Epidemiology, School of Public Health, University of Alabama at Birmingham, Birmingham, AL, USA Purpose: To investigate the ocular neovascularization (ONV rate in eyes with a branch retinal artery occlusion (BRAO or a central retinal artery occlusion (CRAO, and to study factors that may influence the ONV rate secondary to CRAO.Methods: This was a retrospective case series of consecutive patients (286 total eyes: 83 CRAOs and 203 BRAOs who were diagnosed with a retinal artery occlusion from 1998 to 2013 at the Retina Consultants of Alabama and University of Alabama at Birmingham, Birmingham, AL, USA. Generalized estimating equations were used to evaluate the association between hypothesized risk factors and ONV development.Results: Twelve (14.5% of the 83 eyes with a CRAO developed ONV. Eleven of 12 eyes (91.7% had iris neovascularization, ten of 12 eyes (83.3% had neovascular glaucoma, and two of 12 eyes (16.7% had neovascularization of the optic disc. The average time for ONV development secondary to CRAO was 30.7 days, ranging from the date of presentation to 137 days. Only two (<1.0% of the 203 eyes with a BRAO developed iris neovascularization. Diabetes mellitus type 2 was a risk factor for ONV development following a CRAO with an adjusted odds ratio of 5.2 (95% confidence interval: 1.4–19.8 (P=0.02.Conclusion: ONV is an important complication of CRAO and is a less-frequent complication of BRAO. Patients with a CRAO, especially those with diabetes mellitus type 2, should be closely monitored for the first 6 months for ONV. Keywords: neovascularization, neovascular glaucoma, retinal artery occlusion, central

  7. Endovascular Treatment of Central Vein Stenoses and/or Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Maskova, Jana; Komarkova, Jana; Kivanek, Jiri; Danes, Jan; Slavikova, Marcela

    2003-01-01

    Purpose: To report our experience and results with the endovascular treatment of central vein stenoses and occlusions in hemodialysis patients. Methods: Between October 1999 and August 2001 (22 months) we performed 22 interventional procedures in 14 hemodialysis patients (8 women, 6 men) ranging in age from 38 to 87 years (mean 76 years). The indication for intervention was stenosis (n = 10) or occlusion (n =4) of a central vein in the upper arm used for dialysis inpatients with arm swelling and/or shunt malfunction. All patients had a previous history of subclavian vein cannulation. There were six percutaneous transluminal angioplasties (PTAs) and eight primary stentplacements and eight repeat interventions. Seven were for restenoses and one for early occlusion, with two secondary stent placements and six PTA of in-stent stenoses. In two patients a second stent was implanted. The mean follow-up was 8.5 months (range 1-19 months). All stents were self-expandable with diameters ranging from 9 to 16 mm. Results: All but one of the procedures was technically successful (95%, n = 21). The patient with an unsuccessful procedure died 1 month after the procedure, but the death was not procedure-related. During follow-up three patients died with a patent shunt and central vein, none of them in connection with the procedure. No complication occurred during the interventional procedures. One patient was lost to follow-up. The primary patency rate at 12 months was 43%, with a primary assisted patency rate of 83% and a secondary patency rate of 100% (n 6). Conclusion: Central vein stenoses and occlusions are associated with previous subclavian vein cannulation. They are a serious problem in hemodialysis patients with a shunt on the same arm.Endovascular treatment is a suitable option for these patients

  8. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  9. Combined central retinal artery and vein occlusion secondary to systemic non-Hodgkin′s lymphoma

    Directory of Open Access Journals (Sweden)

    Shukla Dhananjay

    2006-01-01

    Full Text Available We report a rare case of low-grade systemic B-cell non-Hodgkin′s lymphoma (NHL causing central retinal artery and vein occlusion, which was the only manifestation of disease recurrence. A young man with resolved systemic NHL underwent fluorescein angiography, magnetic resonance imaging and computed tomography to investigate a severe unilateral visual loss. A combined vascular occlusion was observed in the right eye. Neuroimaging detected optic nerve infiltration; but no systemic/ central nervous system involvement was observed. The patient was treated with high-doses of corticosteroids and optic nerve irradiation. The optic neuropathy and vascular occlusion were resistant to treatment. The subsequent neovascular glaucoma was treated by panretinal photocoagulation, which relieved the pain, but vision was not recovered. No further recurrence was observed over the following year.

  10. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  11. Retinal vascular oximetry during ranibizumab treatment of central retinal vein occlusion

    DEFF Research Database (Denmark)

    Traustason, Sindri; la Cour, Morten; Larsen, Michael

    2014-01-01

    PURPOSE: To investigate the effect of intravitreal injections of the vascular endothelial growth factor inhibitor ranibizumab on retinal oxygenation in patients with central retinal vein occlusion (CRVO). METHODS: Retinal oxygen saturation in patients with CRVO was analysed using the Oxymap Retin...

  12. Using central venous catheter for suprapubic catheterization in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Bilehjani E

    2017-01-01

    Full Text Available Eissa Bilehjani,1 Solmaz Fakhari2 1Department of Cardiovascular Anesthesia, Tabriz University of Medical Sciences, Madani Heart Hospital, 2Department of Anesthesiology, Tabriz University of Medical Sciences, Madani Heart Hospital, Tabriz, Iran Abstract: Suprapubic catheterization is an alternative method for urinary drainage that is used when transurethral catheterization fails. Traditionally, inserted large-bore suprapubic catheters may cause fatal complications. During the past decade, we used a small central venous catheter (CVC suprapubicly in 16 male patients for the purpose of urinary drainage, when transurethral catheterization failed. The procedure is performed in no more than 10 minutes. Success rate was 100% and this approach did not lead to any complications. In conclusion, placing a CVC for suprapubic drainage is a safe method with a high success rate and we recommend it in patients with failed transurethral catheterization after a few attempts (2–3 attempts. Keywords: suprapubic catheterization complication, urethral catheterization, central venous catheter, Seldinger’s technique, cardiac surgery

  13. Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis

    International Nuclear Information System (INIS)

    Ni, Nina; Mojibian, Hamid; Pollak, Jeffrey; Tal, Michael

    2011-01-01

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ 2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P 2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P 2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.

  14. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    Science.gov (United States)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  15. Risk Factors Related to Peripherally Inserted Central Venous Catheter Nonselective Removal in Neonates

    Directory of Open Access Journals (Sweden)

    Xiaohe Yu

    2018-01-01

    Full Text Available We aimed to investigate the incidence and risk factors associated with nonselective removal of peripherally inserted central venous catheter (PICC in neonates. In this prospective cohort study, neonates who underwent PICC placement at neonatal intensive care units (NICUs in China from October 2012 to November 2015 were included. The patient demographics, catheter characteristics, catheter duration, PICC insertion site, indication for PICC insertion, infuscate composition, PICC tip location, and catheter complications were recorded in a computerized database. Risk factors for nonselective removal were analyzed. A total of 497 PICCs were placed in 496 neonates. Nonselective removal occurred in 9.3% of PICCs during 10,540 catheter-days (4.6 nonselective removals per 1,000 catheter-days. These included occlusion (3%, infection (1.4%, leakage (2.0%, phlebitis (0.6%, displacement (1%, pleural effusion(0.6%, and breaks (0.6%. Noncentral tip position was independently associated with an increased risk of nonselective removal (odds ratio 2.621; 95% confidence interval, 1.258-5.461 after adjusting for gestational age, sex, birth weight, and PICC dwell time. No significant differences in the rate of complications occurred between silastic and polyurethane PICC or different insertion sites. Noncentral PICC tip position was the only independent risk factor for nonselective removal of PICC.

  16. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshki Rad

    2015-01-01

    Full Text Available Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56% patients were male subjects and 18 patients (44% were female. Twenty-three (56% patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  17. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    Science.gov (United States)

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  18. Thrombin Avtivable Fibrinolysis Inhibitor in Venous and Arterial Thrombosis

    NARCIS (Netherlands)

    E.L.E. de Bruijne

    2011-01-01

    textabstractVenous and arterial thromboses are major causes of morbidity and mortality. Venous thrombosis is the result of pathological occlusive clot formation in the veins. It occurs mainly in the deep veins of the leg (deep vein thrombosis), from which parts of the clot frequently embolize to the

  19. Renal vein to renal collecting system fistula: An extreme complication from central venous thrombosis secondary to indwelling catheter

    Directory of Open Access Journals (Sweden)

    Aditya Safaya

    2018-04-01

    Full Text Available Central venous catheters are routinely used for resuscitation, chemotherapy and nutrition but are not without risk. Central lines are the most common extrinsic cause of venous thrombosis in neonates and infants. We present an ex-36 week 1800g infant baby girl recovering after a staged repair of gastroschisis with ileostomy and mucous fistula formation. The patient was receiving parenteral nutrition through an indwelling saphenous vein tunneled catheter, with its tip in the inferior vena cava. The patient developed polyuria, with a characteristic odor of the parenteral nutrition and a urine analysis showed glucose and triglyceride levels consistent with the composition of the parenteral nutrition fluid. A fluoroscopic cysto-urogram and an inferior vena-cavogram showed a catheter-associated inferior vena cava thrombosis leading to backpressure changes, diverting all intravenous contrast into the right renal vein and to renal collecting system, thus elucidating the route of the parenteral nutrition fluid reaching the bladder. Our case represents an extreme case of complicated central venous thrombosis. We emphasize the importance of practicing a high index of suspicion for thrombotic complications in severely ill neonates with central venous access. An early diagnosis and aggressive management may prevent progression of the disease towards an overwhelming complication. Keywords: Central venous catheterization complications, Renal vein-collecting system connection, Renal vein- collecting system fistula

  20. Interventional radiology in the provision and maintenance of long-term central venous access

    International Nuclear Information System (INIS)

    Lyon, S.M.; Given, M.; Marshall, N.L.

    2008-01-01

    Establishing and maintaining venous access forms an increasing proportion of the workload in interventional radiology. Several patient groups require medium-term to long-term venous catheters for a variety of purposes, including chemotherapy, long-term antimicrobials, parenteral nutrition, short-term access for haemodialysis or exhausted haemodialysis. Often, these catheters are required for treatment and frequent blood testing, which can quickly exhaust the peripheral veins. Venous access devices include implantable catheters (ports), tunnelled catheters and peripherally inserted central catheters, which have different functions, advantages and limitations. Imaging-guided placement is the preferred method of insertion in many institutions because of higher success rates and radiologists are well suited to address catheter complications.

  1. Pain and efficacy of local anesthetics for central venous access

    Directory of Open Access Journals (Sweden)

    William C Culp Jr

    2008-11-01

    Full Text Available William C Culp Jr1, Mohammed Yousaf2, Benjamin Lowry1, Timothy C McCowan3, William C Culp21Division of Cardiothoracic Anesthesiology, Scott and White Hospital, The Texas A&M University College of Medicine, Temple, TX, USA; 2Division of Interventional Radiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA; 3Department of Radiology, University of Mississippi Medical Center, Jackson, MS, USAPurpose: To compare pain during injection and efficacy of analgesia of local anesthetics during central venous line placement.Methods: Sixty-two patients were studied in a randomized, double-blinded prospective fashion. Patients received 1% lidocaine (L, buffered 1% lidocaine (LB, or 2% chloroprocaine (CP injected around the internal jugular vein for procedural analgesia for central venous access. Patients reported pain via a standard linear visual analog scale, with 0 representing no pain and 10 being the worst pain imaginable.Results: Overall patient perception of pain was better with CP and L than LB with mean scores of CP 2.4, L 2.6, LB 4.2. Pain with injection mean scores were CP 2.1, L 2.5, LB 3.2. Pain with catheter placement scores were CP 2.5, L 1.7, LB 3.4. Operator assessment of overall pain values were CP 1.9, L 2.2, LB 3.4. LB consistently scored the worst, though compared with CP, this only reached statistical significance in overall patient pain and pain at catheter insertion compared with L.Conclusion: Though chloroprocaine scored better than lidocaine in 3 of 4 parameters, this trend did not achieve statistical significance. Adding sodium bicarbonate to lidocaine isn’t justified in routine practice, nor is routine replacement of lidocaine with chloroprocaine.Keywords: local anesthesia, analgesia, central venous access, lidocaine, chloroprocaine

  2. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  3. Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.

    Science.gov (United States)

    Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun

    2015-06-01

    Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (Pcatheterization (Pcatheterization and internal jugular vein catheterization (Pvenous thrombosis history (Pvenous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.

  4. Cryopreserved recombinant tissue plasminogen activator for the restoration of occluded central venous access devices in pediatric oncology patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Al-Katheri, A.; Al-Sedairy, R.; Al-Omari, A.; Abdullah, Mohammed F.; Crankson, S.

    2002-01-01

    Thrombolytic therapy with urokinase 5000 units has been the standard therapy for restoration of thrombosed central catheters. However, with the decreased availability of urokinase, alternatives needed to be sought. The aim of the study was to determine the efficacy, bioactivity, dwell time and cost of cryopreserved recombinant tissue plasminogen activator (rTPA) in the restoration of occluded central venous access devices. For children 10kg, a dose of 1 mg was used. The dwell time was 1-2 hours. Of the 40 courses of rTPA, 39 fully restored central venous line patency (97%). Successful courses were instilled for an average of 1 hour. Cryopreserved rTPA appears to be safe and effective in the dose used to restore the patency of occluded central venous access devices in pediatric oncology patients. (author)

  5. Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial.

    Science.gov (United States)

    Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo

    2017-08-01

    We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.

  6. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  7. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients.

    Science.gov (United States)

    Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien

    2015-11-01

    Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p risk of infection than for patients in a nonadjuvant setting (p ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.

  8. Veno-occlusive disease of the colon - CT findings

    International Nuclear Information System (INIS)

    Rademaker, J.

    1998-01-01

    Venous occlusion is a rare cause of ischemic bowel disease and is usually brought about by thrombosis that may occur as a complication of systemic disorders like systemic lupus erythematosus, Behcet disease or Churg-Strauss syndrome. This report describes a patient with veno-occlusive disease of the colon caused by lymphocytic phlebitis. Typical CT findings included homogeneous bowel wall thickening and vascular engorgement. (orig.) (orig.)

  9. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  10. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  11. Lights, camera and action in the implementation of central venous catheter dressing.

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    To develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. This is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. The items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. The educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  12. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  13. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  14. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  15. Central venous access through the external jugular vein in children submitted to bone marrow transplantation

    Directory of Open Access Journals (Sweden)

    José Luiz de Godoy

    2005-01-01

    Full Text Available Establishment of long-term central venous access is a sine qua non step for bone marrow transplantation in children. Most frequently, long-term central venous access has been obtained via blind percutaneous cannulation of subclavian and internal jugular veins or via internal jugular vein cutdown. In order to avoid some potential minor and major complications associated with the subclavian or internal jugular approaches, the authors describe an easy, simple and safe method for central venous access through an external jugular vein cutdown that should be of interest to readers involved in the field of bone marrow transplantation. It should be also considered for children as well as adults needing central venous access via an external catheter - or totally implantable port - for reasons other than bone marrow transplantation, such as total parenteral nutrition and administration of chemotherapeutic agents.O estabelecimento de um acesso venoso central de longa duração é uma condição sine qua non para realizar o transplante de medula óssea em crianças. Com frequência, este acesso tem sido obtido através da punção percutânea das veias subclávia e jugular interna ou via dissecção da jugular interna. Com o objetivo de evitar algumas complicações maiores e menores associadas com a subclávia e a jugular interna, os autores descrevem um método simples, fácil e seguro para o acesso venoso central através de dissecção da veia jugular externa. Este método deveria ser de interesse dos leitores envolvidos com o transplante de medula óssea e ser considerado também para crianças e/ou adultos que necessitem de cateter venoso central de longa permanência (externo ou totalmente implantável devido a outras razões, como a nutrição parenteral ou a administração de agentes quimioterápicos.

  16. Veno-occlusive disease of the colon - CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Rademaker, J [Department of Radiology I, Medical School Hannover (Germany)

    1998-10-01

    Venous occlusion is a rare cause of ischemic bowel disease and is usually brought about by thrombosis that may occur as a complication of systemic disorders like systemic lupus erythematosus, Behcet disease or Churg-Strauss syndrome. This report describes a patient with veno-occlusive disease of the colon caused by lymphocytic phlebitis. Typical CT findings included homogeneous bowel wall thickening and vascular engorgement. (orig.) (orig.) With 1 fig., 4 refs.

  17. Results of surgery in symptomatic non-hydrocephalic pineal cysts: role of magnetic resonance imaging biomarkers indicative of central venous hypertension.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2017-02-01

    We have previously proposed that pineal cysts (PCs) may result in crowding of the pineal recess, causing symptoms due to compression of the internal cerebral veins and central venous hypertension. In the present study, we compared clinical outcome of different treatment modalities in symptomatic individuals with non-hydrocephalic PCs. The study included all patients managed surgically for non-hydrocephalic PCs in our Department of Neurosurgery over a 10-year period. We applied a questionnaire to determine occurrence of symptoms before and after surgery, which allowed the use of a grading scale for symptom severity. Magnetic resonance imaging (MRI) biomarkers indicative of central venous hypertension were assessed before and after surgery. Relief of symptoms after surgery was most efficiently obtained by complete microsurgical cyst removal [n = 15; no (0/15), some (1/15) or marked (14/15) improvement], and to a lesser extent by microsurgical cyst fenestration [n = 6; no (2/6), some (4/6) or marked (0/6) improvement]. Shunt surgery was not successful [n = 6; no (5/6), some (1/6) or marked (0/6) improvement]. In all patients, the proposed MRI biomarkers gave evidence of central venous hypertension (PC grades 2-4). Microsurgical cyst removal provided marked symptom relief in symptomatic individuals with non-hydrocephalic PCs and MRI biomarkers of central venous hypertension. The hypothesis that PC-induced crowding of the pineal recess may compromise venous run-off and induce a central venous hypertension syndrome deserves further study.

  18. The central retinal artery occlusion in the right eye followed by a branch retinal artery occlusion in the left eye four days later

    Directory of Open Access Journals (Sweden)

    Cagatay Caglar

    2013-01-01

    Full Text Available A 65-year-old woman was admitted to our clinic with complaints of sudden, painless, decrease in vision, and sectoral visual field defect in the left eye and later presented to our clinic again with a history of sudden loss of vision in her right eye. In this case study we reported that the patient had branch retinal artery occlusion (BRAO in the left eye and at the same time progressing central retinal artery occlusion (CRAO in the right eye.

  19. Efficacy observation on multiple wave length laser for diabetic retinopathy and central retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Tao Tian

    2014-07-01

    Full Text Available AIM:To observe the efficacy of the multiple wave length laser in treating diabetic retinopathy combined with central retinal vein occlusion. METHODS:Totally 95 cases(100 eyeswith diabetic retinopathy combined with central retinal vein occlusion were treated by multiple wave length laser. Krypton yellow laser was used for macular edema in focal photocoagulation and diffuse photocoagulation. For peripheral retina, krypton green or krypton red laser were used. Visual acuity, slit-lamp biomicroscopy, ophthalmoscopy and fundus fluorescein angiography were performed preoperatively and postoperatively. The patients were followed up for 12 to 48wk. In this study, change in visual acuity and macular edema were observed in both groups, and statistical analysis was performed. RESULTS:The effective rate was 61.2% in diffuse macular edema group and 86.3% in focal macular edema group. The general effective rate of later was higher than the former, while the treatment effect had significant statistical difference(PCONCLUSION: Multiple wave length laser is an effective and safe way to treat diabetic macular edema of diabetic retinopathy combined with central retinal vein occlusion,which is worth widely applying in clinical practice.

  20. Preventing central venous catheter-related infection in a surgical intensive-care unit

    NARCIS (Netherlands)

    Bijma, R; Girbes, AR; Kleijer, DJ; Zwaveling, JH

    The cumulative effect of five measures (introduction of hand disinfection with alcohol, a new type of dressing, a one-bag system for parenteral nutrition, a new intravenous connection device, and surveillance by an infection control practitioner) on central venous catheter colonization and

  1. An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Engin OZAKIN

    2014-06-01

    Full Text Available SUMMARY: Objectives: In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days following the insertion of central venous catheter under ultrasound guidance in the emergency department. Methods: For this study, patients who presented to the emergency department over a period of eight months with an urgent need for central catheter were examined prospectively. Age, gender, and accompanying diseases of patients as well as the type, time, duration, and indication of the venous access were recorded. Furthermore, the amount of experience of the physician was taken into consideration. Results: In the emergency department, physicians performed ultrasound-guided central venous catheter insertion for 74 patients (40 men and 34 women. For access, internal jugular vein was used in 65 (87.8% patients, and femoral vein was used in 9 (12.2% patients. The reason for access was urgent dialysis need in 55 (74.3%, CVP measurement in 3 (4.1%, fluid support due to severe hypovolemia in 6 (8.1%, and difficulty of peripheral venous access in 10 (13.5% patients. None of the patients developed complications in the process of or after the insertion. Patients did not have infections related to the catheter in 15 days following the insertion. Conclusions: Central venous access is frequently required in emergency departments. The risk of complication is little if any in ultrasonographyguided access carried out under appropriate conditions. ÖZET: Amaç: Acil servislerde acil tıp hekimlerince santral damar yolu işlemi sık uygulanır. Periferik damar yolu açılamadığı hallerde, diyaliz, acil sıvı ihtiyacı veya santral venöz basınç

  2. Lights, camera and action in the implementation of central venous catheter dressing

    Directory of Open Access Journals (Sweden)

    Maria Verônica Ferrareze Ferreira

    2015-12-01

    Full Text Available Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  3. Central Retinal Artery Occlusion in a Patient with Metabolic Syndrome X

    Directory of Open Access Journals (Sweden)

    Sonja Predrag Cekić

    2010-01-01

    Full Text Available Purpose: To report a case of central retinal artery occlusion (CRAO in a patient with metabolic syndrome X. Case Report: A 64 year-old-man presented with abrupt, painless, and severe loss of vision in his left eye. Indirect ophthalmoscopy disclosed signs compatible with CRAO and laboratory investigations revealed erythrocyte sedimentation rate of 74 mm/h, C-reactive protein (CRP level of 21 mg/l, hyperglycemia, hyperuricemia, hypertriglyceridemia and hypercholesterolemia. Fluorescein angiography and immunological studies excluded other systemic disorders. The patient met the full criteria of the National Cholesterol Education Program for metabolic syndrome X. Conclusion: In addition to different vascular complications such as stroke, and cardiovascular disease, metabolic syndrome X may be associated with retinal vascular occlusions.

  4. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  5. Repositioning and Leaving In Situ the Central Venous Catheter During Percutaneous Treatment of Associated Superior Vena Cava Syndrome: A Report of Eight Cases

    International Nuclear Information System (INIS)

    Stockx, Luc; Raat, Henricus; Donck, Jan; Wilms, Guy; Marchal, Guy

    1999-01-01

    Purpose: To describe a combined procedure of repositioning and leaving in situ a central venous catheter followed by immediate percutaneous treatment of associated superior vena cava syndrome (SVCS). Methods: Eight patients are presented who have central venous catheter-associated SVCS (n = 6 Hickman catheters, n = 2 Port-a-cath) caused by central vein stenosis (n = 4) or concomitant thrombosis (n = 4). With the use of a vascular snare introduced via the transcubital or transjugular approach, the tip of the central venous catheter could be engaged, and repositioned after deployment of a stent in the innominate or superior vena cava. Results: In all patients it was technically feasible to reposition the central venous catheter and treat the SVCS at the same time. In one patient flipping of the Hickman catheter in its original position provoked dislocation of the released Palmaz stent, which could be positioned in the right common iliac vein. Conclusion: Repositioning of a central venous catheter just before and after stent deployment in SVCS is technically feasible and a better alternative than preprocedural removal of the vascular access

  6. Central venous catheterization training: current perspectives on the role of simulation

    Directory of Open Access Journals (Sweden)

    Soffler MI

    2018-05-01

    Full Text Available Morgan I Soffler,1,2 Margaret M Hayes,2–4 C Christopher Smith3–5 1Harvard Combined Pulmonary and Critical Care Fellowship at Massachusetts General Hospital and Beth Israel Deaconess Medical Center, Boston, MA, USA; 2Division of Pulmonary, Critical Care, and Sleep Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA; 3Internal Medicine Residency Program, Beth Israel Deaconess Medical Center, Boston, MA, USA; 4Shapiro Institute for Education and Research, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA; 5Division of General Internal Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA Abstract: Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. Keywords: simulation, central venous catheterization, assessment, competency, central line insertion

  7. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  8. Extravasation of parenteral alimentation fluid into the renal pelvis--a complication of central venous catheter in a neonate.

    Science.gov (United States)

    Nadroo, A M; al-Sowailem, A M

    2001-01-01

    Many complications of central venous catheters, which include perforation of the vessel walls and extravasation of the infusate into pericardial, pleural, and peritoneal cavities, have been reported. We report an infant with a central venous catheter in inferior vena cava who experienced extravasation of parenteral alimentation fluid into the right renal pelvis secondary to perforation of the renal vein. To our knowledge, this rare complication has not been reported earlier.

  9. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock

    OpenAIRE

    Mo?ina, Hugo; Podbregar, Matej

    2010-01-01

    Introduction Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the rela...

  10. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  11. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  12. [Doctor-nurse delegation of the insertion of central venous lines].

    Science.gov (United States)

    Cellupica, Mary

    2015-01-01

    The Léon Bérard Cancer Centre treats the disease in all its complexity with numerous disciplines such as surgery, medicine, radiotherapy, palliative care, home care, etc. The insertion of a central venous line is an essential part of cancer care and the nursing profession. It enables patients to have their treatment administered in the best possible conditions and without risk. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  14. Influence of blood flow occlusion on the development of peripheral and central fatigue during small muscle mass handgrip exercise.

    Science.gov (United States)

    Broxterman, R M; Craig, J C; Smith, J R; Wilcox, S L; Jia, C; Warren, S; Barstow, T J

    2015-09-01

    Critical power represents an important threshold for neuromuscular fatigue development and may, therefore, dictate intensities for which exercise tolerance is determined by the magnitude of fatigue accrued. Peripheral fatigue appears to be constant across O2 delivery conditions for large muscle mass exercise, but this consistency is equivocal for smaller muscle mass exercise. We sought to determine the influence of blood flow occlusion during handgrip exercise on neuromuscular fatigue development and to examine the relationship between neuromuscular fatigue development and W '. Blood flow occlusion influenced the development of both peripheral and central fatigue, thus providing further evidence that the magnitude of peripheral fatigue is not constant across O2 delivery conditions for small muscle mass exercise. W ' appears to be related to the magnitude of fatigue accrued during exercise, which may explain the reported consistency of intramuscular metabolic perturbations and work performed for severe-intensity exercise. The influence of the muscle metabolic milieu on peripheral and central fatigue is currently unclear. Moreover, the relationships between peripheral and central fatigue and the curvature constant (W ') have not been investigated. Six men (age: 25 ± 4 years, body mass: 82 ± 10 kg, height: 179 ± 4 cm) completed four constant power handgrip tests to exhaustion under conditions of control exercise (Con), blood flow occlusion exercise (Occ), Con with 5 min post-exercise blood flow occlusion (Con + Occ), and Occ with 5 min post-exercise blood flow occlusion (Occ + Occ). Neuromuscular fatigue measurements and W ' were obtained for each subject. Each trial resulted in significant peripheral and central fatigue. Significantly greater peripheral (79.7 ± 5.1% vs. 22.7 ± 6.0%) and central (42.6 ± 3.9% vs. 4.9 ± 2.0%) fatigue occurred for Occ than for Con. In addition, significantly greater peripheral (83.0 ± 4.2% vs. 69.0 ± 6.2%) and central

  15. Spontaneous migration of central venous catheter tip following extubation

    Directory of Open Access Journals (Sweden)

    Balaji Prabaharan

    2014-01-01

    Full Text Available Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

  16. Usefulness of Totally Implantable Central Venous Access Devices in Elderly Patients: A Retrospective Study.

    Science.gov (United States)

    Imaoka, Yuki; Kuranishi, Fumito; Ogawa, Yoshiteru

    2018-01-01

    The need for totally implantable central venous access devices (TICVADs) has increased with increased opportunities in the use of chemotherapy and parenteral nutrition. This study aimed to determine the outcomes of TICVAD implantation and use in patients aged ≥85 years. Between January 2010 and August 2016, 117 patients underwent TICVAD implantation and their records were retrospectively reviewed. Participants were divided into 2 groups (plus-85 and sub-85 groups). Fifty-five patients (47.0%) had solid organ cancer alone; 35 patients (29.9%) had cerebrovascular or cranial nerve disease. The average follow-up period was 201 (2-1,620) days. Major complications were identified in 6 (14.6%) plus-85 patients and 11 (14.5%) sub-85 patients (p = 0.9813). Catheter-related infections developed in 3 plus-85 (7.3%) and 4 sub-85 patients (5.3%; p = 0.6549). There were no significant group differences in hematoma, pneumothorax, occlusion, and removal rates. In plus-85 patients examined just before surgery and a month after surgery, increased rates of serum albumin and Onodera's prognostic nutritional index were observed in 48% (14/39) and 41% (12/39), respectively. The use of TICVADs in the plus-85 group resulted in effective outcomes. The results of this retrospective study support the wider use of TICVADs in patients aged ≥85 years. © 2018 S. Karger AG, Basel.

  17. Simulation training for pediatric residents on central venous catheter placement: a pilot study.

    Science.gov (United States)

    Thomas, Scott M; Burch, Wesley; Kuehnle, Sarah E; Flood, Robert G; Scalzo, Anthony J; Gerard, James M

    2013-11-01

    To assess the effect of simulation training on pediatric residents' acquisition and retention of central venous catheter insertion skills. A secondary objective was to assess the effect of simulation training on self-confidence to perform the procedure. Prospective observational pilot study. Single university clinical simulation center. Pediatric residents, postgraduate years 1-3. Residents participated in a 60- to 90-minute ultrasound-guided central venous catheter simulation training session. Video recordings of residents performing simulated femoral central venous catheter insertions were made before (baseline), after, and at 3-month following training. Three blinded expert raters independently scored the performances using a 24-item checklist and 100-mm global rating scale. At each time point, residents rated their confidence to perform the procedure on a 100-mm scale. Twenty-six residents completed the study. Compared with baseline, immediately following training, median checklist score (54.2% [interquartile range, 40.8-68.8%] vs 83.3% [interquartile range, 70.0-91.7%]), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 79.5 mm [interquartile range, 16.3-91.7 mm]), success rate (38.5% vs 80.8%), and self-confidence (8.0 mm [interquartile range, 3.8-19.0 mm] vs 52.0 mm [interquartile range, 43.5-66.5 mm]) all improved (p interquartile range, 40.8-68.8%] vs 54.2% [interquartile range, 45.8-80.4%], p = 0.47), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 35.5 mm [interquartile range, 5.3-77.0], p = 0.62), and success rate (38.5% vs 65.4%, p = 0.35) were similar at 3-month follow-up. Self-confidence, however, remained above baseline at 3-month follow-up (8.0 mm [interquartile range, 3.8-19.0 mm] vs 61.0 mm [interquartile range, 31.5-71.8 mm], p < 0.01). Simulation training improved pediatric residents' central venous catheter insertion procedural skills. Decay in skills was found at 3-month follow-up. This suggests that

  18. STUDY OF CENTRAL VENOUS CATHETER RELATED BLOOD STREAM INFECTIONS IN PATIENTS ON HAEMODIALYSIS

    Directory of Open Access Journals (Sweden)

    Pranjal Pankaj

    2018-01-01

    Full Text Available BACKGROUND Temporary and permanent central venous catheters are used in majority of patients of CKD when initiated on hemodialysis and mostly these catheters act as bridge before permanent AV fistula assess could be obtained. Blood stream infections related to these central venous catheters are an important cause of morbidity and mortality in these patients. Appropriate antiseptic precautions while inserting central venous catheter and early identification of catheter related blood stream infections (CRBSI are of utmost importance for reducing hospital stay, cost of therapy and mortality. MATERIALS AND METHODS A total of 50 patients of CKD were included in the study who had central venous catheter in situ (internal jugular or subclavian and developed symptoms related to blood stream infections. Blood cultures were obtained from the catheter lumen and a separate venous site 1 hour apart. All the culture sensitivity reports were obtained from department of microbiology of our institute. Inclusion Criteria- Known case of CKD patients aged more than 18yrs on hemodialysis with symptoms and signs of catheter related blood stream infections were included in the study. Exclusion Criteria- Patients with other associated comorbid infections like Koch’s, urinary tract infection or others mimicking symptoms of CRBSI. RESULTS The cultures were found positive in 38 patients (76% while in rest 24% cases positive cultures could not be obtained. Out of culture positive patients 52.63% cases were found to have gram positive infections while 44.74% had gram negative infections. In 2.63% patients, fungus was isolated to be the causative organism. Among the gram positive organisms 50% had CoNS, 30% had MSSA and 20% had MRSA infections. Among the gram negative group, 47.06% had klebsiella, 23.53% had acinetobacter, 17.65% had E.coli and 11.76% had pseudomonas as the causative organisms. Mortality was observed in 14% patients out of which 28.57% were culture

  19. Lights, camera and action in the implementation of central venous catheter dressing1

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters. PMID:26626011

  20. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.; Siegel, Randall L.; Biswal, Rajiv; Gribbin, Christopher E.; Tokarz, Robert

    2000-01-01

    (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports.Conclusion: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports

  1. Combined central retinal artery and vein occlusion with optic perineuritis following herpes zoster dermatitis in an immunocompetent child.

    Science.gov (United States)

    Bansal, Reema; Singh, Ramandeep; Takkar, Aastha; Lal, Vivek

    2017-11-01

    A 15-year-old healthy boy developed acute, rapidly progressing visual loss in left eye following herpes zoster dermatitis, with a combined central retinal artery occlusion (CRAO) and central retinal vein occlusion (CRVO), along with optic perineuritis. Laboratory tests were negative. Despite an empirical, intensive antiviral treatment with systemic corticosteroids, and vision could not be restored in the affected eye. Herpes zoster dermatitis, in an immunocompetent individual, may be associated with a combined CRAO and CRVO along with optic perineuritis, leading to profound visual loss.

  2. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    Science.gov (United States)

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  3. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  4. Peripherally inserted central catheters in infants and children - indications, techniques, complications and clinical recommendations

    DEFF Research Database (Denmark)

    Westergaard, B; Classen, V; Walther-Larsen, S

    2013-01-01

    of perioperative complications. Assisted visualisation, preferably with ultrasound, yields high rates of insertion success. With good catheter care, rates of mechanical, infectious and thrombotic complications are low and compare favourably with those of traditional central venous catheters. Even in the case...... of occlusion or infection, fibrinolytics and antibiotic locks often allow the catheter to be retained....

  5. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  6. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2015-11-01

    Conclusion: Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings.

  7. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    Science.gov (United States)

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. THE RESULTS OF RADIAL OPTIC NEUROTOMY FOR TREATMENT OF CENTRAL RETINAL VEIN OCCLUSION

    Directory of Open Access Journals (Sweden)

    S A Tabatabaii

    2008-11-01

    Full Text Available "nCentral retinal vein occlusion (CRVO is the third most common blinding vascular retinal disorder. As there is no proven treatment for CRVO, we performed this study to evaluate the effectiveness of radial optic neurotomy (RON on visual acuity in eyes with CRVO. This study was designed as an interventional case series. Pars plana vitrectomy with RON was performed in 18 eyes of 16 patients with ischemic CRVO with visual acuities of 20/400 or less. Postoperative and preoperative visual acuities were compared using t paired test. Mean preoperative visual acuity was 20/1000 (range, 20/1600 to 20/630. Mean follow-up time was 3.6 months (range, 1 to 9 months. Mean postoperative visual acuity was 20/400 (range, 20/1600 to 20/50 at last follow-up and the difference was significant (P < 0.01; t paired test. Six patients (33% improved to 20/200 postoperatively. There were no major complications intraoperatively. Chorioretinal shunts developed in neurotomy site in 9 cases (50% 4 to 10 weeks after procedure which were associated with faster resolving of hemorrhage and venous dilation. There were no major complications noted with this procedure but vitreous hemorrhage and iris neovascularization was observed in the early postoperative period in 2 (11% of 18 cases. RON may improve visual acuity in eyes with CRVO. It is a technically feasible and fairly safe procedure but postoperatively it may result in some complications such as vitreous hemorrhage, iris neovascularization and retinal detachment.

  9. Bilateral Pneumothoraces Following Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    F. Pazos

    2009-01-01

    Full Text Available We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax.

  10. Bilateral Pneumothoraces Following Central Venous Cannulation

    Science.gov (United States)

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  11. Radial optic neurotomy for ischaemic central vein occlusion

    Science.gov (United States)

    Martínez-Jardón, C S; Meza-de Regil, A; Dalma-Weiszhausz, J; Leizaola-Fernández, C; Morales-Cantón, V; Guerrero-Naranjo, J L; Quiroz-Mercado, H

    2005-01-01

    Background/aims: Ischaemic central retinal vein occlusion (CRVO) accounts for 20–50% of all CRVO. No treatment has been proved to be effective. The efficacy of radial optic neurotomy (RON) was evaluated in eyes with ischaemic CRVO. Methods: 10 patients with ischaemic CRVO underwent RON. After pars plana vitrectomy, a microvitreoretinal blade was used to incise the scleral ring, cribriform plate, and adjacent sclera at the nasal edge of the optic disc. Best corrected visual acuity (BCVA), intraocular pressure (IOP), fluorescein angiography (FA), multifocal electroretinography (mfERG), and optical coherence tomography (OCT) were measured preoperatively and at 1, 3, and 6 months postoperatively. Results: No visual improvement was noted in the eyes that underwent RON. FA and mfERG showed no increase in retinal perfusion or retinal function postoperatively. Mean macular central thickness changed from 841 (SD 170) μm preoperatively to 162 (SD 34) μm at the sixth postoperative month. One patient had retinal central artery perforation intraoperatively. One patient developed neovascular glaucoma. Conclusion: RON in ischaemic CRVO did not improve visual function (by mfERG) or visual acuity although macular thickness did improve. This technique may be associated with potential risks. Randomised studies are needed to corroborate these results. PMID:15834084

  12. Anti vascular endothelial growth factor (bevacizumab) in central retinal vein occlusion: an interventional case series

    International Nuclear Information System (INIS)

    Jan, S.; Khan, M.N.; Karim, S.; Khan, M.T.; Hussain, Z.; Khan, S.; Nazim, M.

    2010-01-01

    Vascular endothelial growth factor plays major role in ocular angio genesis and retinal edema production and is a step forward in the management of ocular neovascularization and retinal edematous pathologies. To determine the efficacy and safety of intra-vitreal Avastin (Bevacizumab) in cases having central retinal vein occlusion. All patients with central retinal occlusion occurring in the past 3 months and seen between the study period were included in the study. Diagnosis of central retinal vein occlusion was made clinically by slit lamp biomicroscopy with 78D examination Patients who had received any treatment for and eyes which already had developed Anterior Segment Neovascularization, Neovascularization elsewhere or Neovascularization on disc at presentation were excluded. Dose of 0.05 ml (1.25mg) of Avastin (Bevacizumab) was used as intra vitreal injection every month for 3 months in cases that presented within a month of occlusion and less injections were given in dose presenting later. Follow-up was done at 30th, 60th, 90th and 120th day after the onset of disease. Visual outcome was defined as Snellen's or LogMar Best Corrected Visual Acuity at final follow up, of 120th day, compared to the visual acuity at presentation. Data were analyzed by SPSS version 17. Total of 17 eyes of 17 patients were included in this study. Eleven (64.7%) patients were males while 6(35.3%) were females. Total of 40 intra-vitreal injections of Avastin were given to patients with a mean of 2.35 injections per eye. Good visual outcome was achieved in 10(58.8%) eyes, while 7(41.2%) had stable visual outcome. Mean initial Best Corrected Visual Acuity (LogMar) in all 17 eyes was 1.79(SD+0.87) which significantly improved to a mean of 1.18 (SD+0.77) at final follow up. Mean improvement in Best Corrected Visual Acuity (LogMar) after paired sample test in all patients at final follow up on day 120 was 0.61(SD+0.84). Retinal hemorrhages and macular edema decreased clinically on

  13. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  14. Cardiac tamponade in an infant during contrast infusion through central venous catheter for chest computed tomography; Tamponamento cardiaco durante infusao de contraste em acesso venoso central para realizacao de tomografia computadorizada do torax em lactente

    Energy Technology Data Exchange (ETDEWEB)

    Daud, Danilo Felix; Campos, Marcos Menezes Freitas de; Fleury Neto, Augusto de Padua [Hospital Geral de Palmas, TO (Brazil)

    2013-11-15

    Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein. (author)

  15. MRI and CT in cerebral venous thrombosis

    International Nuclear Information System (INIS)

    Surur, Alberto; Marangoni, Alberto; Devallis, Juan P.; Galvez, Vasco; Marchegiani, Silvio; Galletti, Cayetano; Martin, Juan J.

    2004-01-01

    Purpose: The veno-occlusive encephalic disease is a neurologic disorder of difficult clinic diagnostic almost always. This clinic situation presents a high morbi-mortality range without an early and precise diagnostic. With the use of Helical Computed Tomography (HCT) and Angio Magnetic Resonance Image (AMRI) the diagnosis has became more effective in the encephalic venous thrombosis. Methods: Fourteen patients with clinical suspicion on encephalic venous thrombosis using non-invasive techniques as HCT and AMRI were studied. Results: In all these cases we were able to arrive at the exact etiologic diagnostic using these techniques associated to the clinics findings, without needing the use of another invasive method like Angiography. Conclusion: The results were satisfactory for definitive diagnosis, without Angiography. When a patient has a high suspicion of veno-occlusive disease the neuro radiologic examination in the urgency is a very important fact and using HCT and AMRI as the first examinations techniques it is possible to obtain good results without most aggressive techniques. (author)

  16. Clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting

    Directory of Open Access Journals (Sweden)

    Xiang-yu CAO

    2016-12-01

    Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected.  Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001.  Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein

  17. Central Retinal and Posterior Ciliary Artery Occlusion After Intralesional Injection of Sclerosant to Glabellar Subcutaneous Hemangioma

    International Nuclear Information System (INIS)

    Matsuo, Toshihiko; Fujiwara, Hiroyasu; Gobara, Hideo; Mimura, Hidefumi; Kanazawa, Susumu

    2009-01-01

    The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed no perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.

  18. Endovascular management of deep venous thrombotic diseases of the lower extremity

    International Nuclear Information System (INIS)

    Roh, Byung Suk

    2004-01-01

    Pulmonary embolism and venous ischemia are acute complications of deep vein thrombosis (DVT) of the lower extremities. Delayed complications include a spectrum of debilitating symptoms referred to as postthrombotic syndrome (PST). Because the early symptoms and patient signs are nonspecific for DVT, careful history taking and radiological evaluation of the extent and migration of thrombus should be used to establish an objective diagnosis and the need for treatment. Anticoagulation therapy is recognized as the mainstay treatment in acute DVT. However, there are few data to suggest any major beneficial effect of the early clearing of massive DVT and PTS. Endovascular, catheter-directed, thrombolysis techniques, used alone or in combination with mechanical thrombectomy devices, have been proven to be highly effective in clearing acute DVT, which may allow the preservation of venous valve function and the prevention of subsequent venous occlusive disease. Definitive management of the underlying anatomic occlusive abnormalities should also be undertaken

  19. Endovascular management of deep venous thrombotic diseases of the lower extremity

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    2004-07-01

    Pulmonary embolism and venous ischemia are acute complications of deep vein thrombosis (DVT) of the lower extremities. Delayed complications include a spectrum of debilitating symptoms referred to as postthrombotic syndrome (PST). Because the early symptoms and patient signs are nonspecific for DVT, careful history taking and radiological evaluation of the extent and migration of thrombus should be used to establish an objective diagnosis and the need for treatment. Anticoagulation therapy is recognized as the mainstay treatment in acute DVT. However, there are few data to suggest any major beneficial effect of the early clearing of massive DVT and PTS. Endovascular, catheter-directed, thrombolysis techniques, used alone or in combination with mechanical thrombectomy devices, have been proven to be highly effective in clearing acute DVT, which may allow the preservation of venous valve function and the prevention of subsequent venous occlusive disease. Definitive management of the underlying anatomic occlusive abnormalities should also be undertaken.

  20. Hepatic veno-occlusive disease associated with comfrey ingestion.

    Science.gov (United States)

    Yeong, M L; Swinburn, B; Kennedy, M; Nicholson, G

    1990-01-01

    A 23 year old man presented with hepatic veno-occlusive disease and severe portal hypertension and subsequently died from liver failure. Light microscopy and hepatic angiography showed occlusion of sublobular veins and small venous radicles of the liver, associated with widespread haemorrhagic necrosis of hepatocytes. The patient had been on a predominantly vegetarian diet and, prior to his illness, took comfrey leaves which are known to contain hepatotoxic pyrrolizidine alkaloids. Comfrey is widely used as a herbal remedy, but so far has only been implicated in two other documented cases of human hepatic veno-occlusive disease. A possible causal association of comfrey and this patient's veno-occlusive disease is suggested by the temporal relationship of the ingestion of comfrey to his presentation, the histological changes in the liver and the exclusion of other known causes of the disease.

  1. Pretreatment with remifentanil, fentanyl, or lidocaine to prevent withdrawal after rocuronium using venous occlusion technique in children and adolescents: a prospective randomized placebo-controlled double-blind study.

    Science.gov (United States)

    Abu-Halaweh, S A; Aloweidi, A K; Qudaisat, I Y; Al-Hussami, M O; Al Zaben, K R; Abu-Halaweh, A S

    2014-12-01

    Pain caused by intravenous injection of the muscle relaxant rocuronium bromide is common in children and adolescents. The cause of this unwanted effect is still unclear, and different pretreatment drugs have been administered in attempts to alleviate this side effect, with varying degrees of success. This study used a 60-s venous occlusion technique to evaluate the effectiveness of pretreatment with lidocaine, fentanyl, or remifentanil in preventing pain-induced withdrawal caused by intravenous injection of rocuronium bromide during the induction of general anesthesia. One hundred and one child and adolescent patients, ASA Ι-II, requiring various surgical procedures under general anesthesia with muscle relaxation and mechanical ventilation, were enrolled. Patients were allocated randomly using computer-generated randomization into one of four pretreatment groups: a remifentanil group (1 µg/kg, n = 25), fentanyl group (1 µg/kg, n = 26), lidocaine 1% group (0.5 mg/kg, n = 25), and normal saline group (n = 25). Drug doses were prepared in normal saline to a total volume of 5 ml. Venous occlusion was applied 10 cm above the venous access site. Pretreatment drugs were injected and retained for 60 s at the site of injection by an anesthetist blinded to group allocation. After release of the tourniquet, rocuronium (0.5 mg/kg) was then injected over 5 s, and withdrawal was recorded by another anesthetist blinded to group allocation. Descriptive statistics, analysis of variance, and a chi-squared test were used to statistically analyze the results as appropriate. Compared to normal saline, all other pretreatment groups scored a significantly lower mean of withdrawal response (P rocuronium injection. Remifentanil was superior to fentanyl in suppressing the withdrawal response caused by rocuronium injection (P rocuronium injection in children and adolescents. Lidocaine was superior to remifentanil which, in turn, was more effective than fentanyl.

  2. Comparison of three types of central venous catheters in patients with malignant tumor receiving chemotherapy

    Directory of Open Access Journals (Sweden)

    Fang S

    2017-07-01

    Full Text Available Shirong Fang,1 Jinhong Yang,2 Lei Song,3 Yan Jiang,1 Yuxiu Liu4 1Department of Anesthesiology, 2Department of Oncology, Weifang People’s Hospital, Weifang, 3Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao, 4Nursing College, Weifang Medical University, Weifang, People’s Republic of China Background: Central venous catheters (CVCs have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs, and external non-tunneled central venous catheters (NTCs.Methods: A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal.Results: There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion: Although port catheterization costs more and needs professional medical staff and strict operational

  3. Arterial and venous revascularization with bifurcation of a single central artery: a reliable strategy for Tamai Zone I replantation.

    Science.gov (United States)

    Hsu, Chung-Chen; Lin, Yu-Te; Moran, Steven L; Lin, Cheng-Hung; Wei, Fu-Chan; Lin, Chih-Hung

    2010-12-01

    Replantation of the distal phalanx and pulp can be performed to improve finger function and finger aesthetics; however, establishing adequate venous drainage is a challenge. Slattery et al. reported microsurgical reattachment of a partial distal phalanx with the use of a bifurcated terminal digital artery. The bifurcation was divided into two pedicles, one of which was used for venous drainage. In this article, the authors report their experience with a similar technique and propose a new algorithm for distal finger replantation. From January of 2008 to February of 2009, five replantations were performed using a single central artery. The replanted levels were pulp, avulsed fingertip of the thumb, and distal phalanges. There was no volar vein, dorsal vein, or second artery available in the amputated part for standard venous drainage. Venous drainage in all cases was established by creating an anastomosis from a branch of the solitary terminal artery to a recipient vein. All digits were replanted successfully without evidence of arterial insufficiency or venous congestion. Partial necrosis was not identified postoperatively in any of the five fingers. There were no cases of wound infection. A branch of the central solitary artery may be used successfully to reestablish venous outflow in cases of distal finger tip replantation. This technique allowed for the salvage of all fingers in this study without the use of leeches or other techniques used in cases of venous insufficiency.

  4. Central venous oxygenation: when physiology explains apparent discrepancies.

    Science.gov (United States)

    Squara, Pierre

    2014-11-10

    Central venous oxygen saturation (ScvO2) >70% or mixed venous oxygen saturation (SvO2) >65% is recommended for both septic and non-septic patients. Although it is the task of experts to suggest clear and simple guidelines, there is a risk of reducing critical care to these simple recommendations. This article reviews the basic physiological and pathological features as well as the metrological issues that provide clear evidence that SvO2 and ScvO2 are adaptative variables with large inter-patient variability. This variability is exemplified in a modeled population of 1,000 standard ICU patients and in a real population of 100 patients including 15,860 measurements. In these populations, it can be seen how optimizing one to three of the four S(c)vO2 components homogenized the patients and yields a clear dependency with the fourth one. This explains the discordant results observed in large studies where cardiac output was increased up to predetermined S(c)vO2 thresholds following arterial oxygen hemoglobin saturation, total body oxygen consumption needs and hemoglobin optimization. Although a systematic S(c)vO2 goal-oriented protocol can be statistically profitable before ICU admission, appropriate intensive care mandates determination of the best compromise between S(c)vO2 and its four components, taking into account the specific constraints of each individual patient.

  5. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  6. Reverse Trendelenburg position is a safer technique for lowering central venous pressure without decreasing blood pressure than clamping of the inferior vena cava below the liver.

    Science.gov (United States)

    Yoneda, Godai; Katagiri, Satoshi; Yamamoto, Masakazu

    2015-06-01

    Bleeding remains an important intraoperative complication in patients who undergo hepatectomy. It is generally believed that a reduction in central venous pressure will decrease bleeding from the hepatic venous system. To our knowledge, however, no study has compared the effectiveness of these techniques for controlling bleeding. So we compared the effectiveness of central venous pressure control techniques, such as infrahepatic inferior vena cava clamping, changes in surgical position of the patient, and hypoventilation anesthesia, for lowering central venous pressure. The study group comprised 50 patients who underwent hepatectomy in our department from 2012 through 2013. A central venous catheter was inserted into the right internal jugular vein, and the tip was placed in the superior vena cava. A transducer was placed along the mid-axillary line of the left side of the chest. After opening the abdomen, changes in central venous pressure were measured during inferior vena cava clamping, the reverse Trendelenburg position, the Trendelenburg position, and hypoventilation anesthesia. The inclination relative to the transducer, as measured with an inclinometer, was -10 degrees for the Trendelenburg position and +10 degrees for the reverse Trendelenburg position. The tidal volume was set at 10 mL/kg during conventional anesthesia and 5 mL/kg during hypoventilation anesthesia. The mean central venous pressure was 8.0 cm H(2)O in the supine position during conventional anesthesia, 5.0 cm H(2)O during inferior vena cava clamping, 5.6 cm H(2)O during reverse Trendelenburg position, 10.6 cm H(2)O during Trendelenburg position, and 7.6 cm H(2)O during hypoventilation anesthesia. The mean central venous pressure during inferior vena cava clamping and reverse Trendelenburg position was significantly lower than that during supine position (P = 0.0017 and P = 0.0231, respectively). The mean central venous pressure during hypoventilation

  7. [Central retinal vein occlusion as the first symptom of ovarian cancer].

    Science.gov (United States)

    Asensio-Sánchez, V M; Hernaez-Ortega, M C; Castresana-Jauregui, I

    2013-12-01

    A healthy 57-year-old woman presented with decreased vision in her right eye. Dilated fundus examination revealed central retinal vein occlusion (CRVO). The laboratory test results for hypercoagulability state showed an abnormal protein S. A few months later she developed an ovarian malignancy. This case illustrates an association between CRVO and ovarian tumour. Coagulation disorders in cancer may be a mechanism for CRVO. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  8. Radiologic placement of hemodialysis central venous catheters: a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Schemmer, D.; Sadler, D.J.; Gray, R.R.; Saliken, J.C.; So, C.B. [Foothills Hospital, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)

    2001-04-01

    Typical indications for central venous catheters (CVCs) are hemodialysis (HD), apheresis, total parenteral nutrition, analgesia, chemotherapy, long-term antibiotic therapy and cases of difficult or absent peripheral venous access. One of the largest medical services requesting CVC insertion is nephrology for HD patients. Demographics dictate that the demand for CVCs will continue to grow over the next few decades, placing striking demands on interventional radiology departments. In our centre, interventional radiologists now place nearly all percutaneously inserted HD CVCs. Radiologists provide rapid access to CVC services with significantly fewer complications than CVCs placed by other clinicians. With the demand for CVC management increasing and available operating room time decreasing, many clinicians now refer CVC insertions to radiologists. As well, clinicians who ordinarily place their own lines often refer high-risk patients, such as those who are obese or uncooperative and those with burns or coagulopathy. Our experience, derived from over 7000 CVC insertions, manipulations and removals, has allowed us to continually progress and improve our techniques, many of which are summarized here. (author)

  9. Clinical presentation of multiple cerebral emboli and central retinal artery occlusion (CRAO as signs of cardiac myxoma

    Directory of Open Access Journals (Sweden)

    Alberto Galvez-Ruiz

    2018-04-01

    Full Text Available Cardiac myxomas are benign tumors of endocardial origin that usually occur in the left atrium. Trans-thoracic echocardiography is the diagnostic method of choice, and early surgical removal is the preferred method of treatment.We present a patient whose history of cerebral emboli and central retinal artery occlusion (CRAO led to a diagnosis of cardiac myxoma.Neuroimaging studies showed multiple infarcts in the region of the left middle and anterior cerebral arteries. Ophthalmic examination showed gross retinal pallor compatible with left central retinal artery occlusion (CRAO.The etiology of stroke was investigated by performing trans-thoracic echocardiography, which showed a mass in the left atrium compatible with cardiac myxoma. Complete removal of the cardiac tumor was performed by open-heart surgery.Fortunately, after a period of rehabilitation, the patient’s hemiparesis almost completely resolved, but the loss of vision OS remained unchanged.Many cases of myxoma are accompanied by constitutional symptoms, such as anemia, fever and weight loss, which allow for a diagnosis to made before serious complications such as embolism occur. Unfortunately, in some patients, such as ours, the absence of signs and symptoms allows the myxoma to pass completely unnoticed until the first embolic event occurs. Keywords: Cardiac myxoma, Central retinal artery occlusion, Cerebral emboli, Amaurosis

  10. Retrospective analysis of intravertebral collateral enhancement in patients with central venous obstruction

    International Nuclear Information System (INIS)

    Simeone, F.J.; Chang, Connie Y.; Huang, Ambrose J.; Kattapuram, Susan V.; Bredella, Miriam A.; Torriani, Martin; Bennett, Debbie L.

    2016-01-01

    To compare prevalence and patterns of intravertebral collateral enhancement in patients with and without central venous obstruction (CVO). Chest CTs performed between 1/1/2000 and 12/15/2012 with reports containing terms indicating CVO were identified. All contrast enhanced CTs were examined for the presence of CVO and collateral venous pathways. If intravertebral collateral enhancement was present, the pattern was recorded as nodular, linear, or both. In 209 suspected cases of CVO, 53 (25 %) were confirmed with obstruction and 156 (75 %) were without obstruction. In patients with CVO, 47 % (25/53) demonstrated collateral venous flow through an intravertebral marrow pathway compared to 5 % (8/156) of patients without CVO (P < 0.0001). The most common level of enhancement was the upper thoracic spine, involving only the vertebral body. Nodular, linear, and combined nodular-linear enhancement patterns were seen with similar frequency. Nodular intravertebral collateral enhancement was mistaken for sclerotic metastases in 33 % (3/9) of cases. Intravertebral collateral enhancement was seen in almost half the patients with CVO and when nodular enhancement is present, it is important to differentiate between metastatic lesions and enhancement related to CVO. (orig.)

  11. Retrospective analysis of intravertebral collateral enhancement in patients with central venous obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Simeone, F.J.; Chang, Connie Y.; Huang, Ambrose J.; Kattapuram, Susan V.; Bredella, Miriam A.; Torriani, Martin [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Bennett, Debbie L. [Saint Louis University School of Medicine, Department of Radiology, Saint Louis, MO (United States)

    2016-02-15

    To compare prevalence and patterns of intravertebral collateral enhancement in patients with and without central venous obstruction (CVO). Chest CTs performed between 1/1/2000 and 12/15/2012 with reports containing terms indicating CVO were identified. All contrast enhanced CTs were examined for the presence of CVO and collateral venous pathways. If intravertebral collateral enhancement was present, the pattern was recorded as nodular, linear, or both. In 209 suspected cases of CVO, 53 (25 %) were confirmed with obstruction and 156 (75 %) were without obstruction. In patients with CVO, 47 % (25/53) demonstrated collateral venous flow through an intravertebral marrow pathway compared to 5 % (8/156) of patients without CVO (P < 0.0001). The most common level of enhancement was the upper thoracic spine, involving only the vertebral body. Nodular, linear, and combined nodular-linear enhancement patterns were seen with similar frequency. Nodular intravertebral collateral enhancement was mistaken for sclerotic metastases in 33 % (3/9) of cases. Intravertebral collateral enhancement was seen in almost half the patients with CVO and when nodular enhancement is present, it is important to differentiate between metastatic lesions and enhancement related to CVO. (orig.)

  12. Quantitative estimation of compliance of human systemic veins by occlusion plethysmography with radionuclide

    International Nuclear Information System (INIS)

    Takatsu, Hisato; Gotoh, Kohshi; Suzuki, Takahiko; Ohsumi, Yukio; Yagi, Yasuo; Tsukamoto, Tatsuo; Terashima, Yasushi; Nagashima, Kenshi; Hirakawa, Senri

    1989-01-01

    Volume-pressure relationship and compliance of human systemic veins were estimated quantitatively and noninvasively using radionuclide. The effect of nitroglycerin (NTG) on these parameters was examined. Plethysmography with radionuclide (RN) was performed using the occlusion method on the forearm in 56 patients with various cardiac diseases after RN angiocardiography with 99m Tc-RBC. The RN counts-venous pressure curve was constructed from (1) the changes in radioactivity from region of interest on the forearm that were considered to reflect the changes in the blood volume of the forearm, and (2) the changes in the pressure of the forearm vein (fv) due to venous occlusion. The specific compliance of the forearm veins (Csp.fv; (1/V)·(ΔV/ΔP)) was obtained graphically from this curve at each patient's venous pressure (Pv). Csp.fv was 0.044±0.012 mmHg -1 in class I (mean±SD; n=13), 0.033±0.007 mmHg -1 in class II (n=30), and 0.019±0.007 mmHg -1 in class III (n=13), of the previous NYHA classification of work tolerance. There were significant differences in Csp.fv among the three classes. The systemic venous blood volume (Vsv) was determined by subtracting the central blood volume, measured by RN-angiocardiography, from total blood volume, measured by the indicator dilution method utilizing 131 I-human serum albumin. Systemic venous compliance (Csv) was calculated from Csv=Csp.fv·Vsv. The Csv was 127.2±24.8 ml·mmHg -1 (mean±SD) in class I, 101.1±24.1 ml·mmHg -1 in class II and 62.2±28.1 ml·mmHg -1 in class III. There were significant differences in Csv among the three classes. The class I Csv value was calculated to be 127.2±24.8 ml·mmHg -1 and the Csv/body weight was calculated to be 2.3±0.7 ml·mmHg -1 ·kg -1 of body weight. The administration of NTG increased Csv significantly in all cases. (J.P.N.)

  13. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  14. When one port does not return blood: two case reports of rare causes for misplaced central venous catheters

    Directory of Open Access Journals (Sweden)

    Sandra Pereira

    2016-01-01

    Full Text Available We present two cases of misplaced central venous catheters having in common the absence of free blood return from one lumen immediately after placement. The former is a case of right hydrothorax associated with central venous catheterization with the catheter tip in intra-pleural location. In this case the distal port was never patent. In the latter case there was an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not be undervalued. In these circumstances the catheter should not be used and needs to be removed. Resumo: Apresentamos dois casos de mau posicionamento de cateter venoso central. Têm em comum a ausência do retorno sanguíneo livre em um dos lúmens imediatamente após a colocação. O primeiro é um caso de hidrotórax direito associado ao cateterismo venoso central, com a ponta do cateter em localização intrapleural. Nesse caso, a porta distal nunca esteve patente. No segundo caso houve um aumento da pressão de aspiração através da porta medial por causa da formação de alça no cateter.A ausência de fluxo livre na aspiração de um lúmen do cateter central não deve ser subestimada. Nessas circunstâncias, o cateter não deve ser usado e deve ser removido. Keywords: Central venous catheter, Hydrothorax, Looping, Malposition, Palavras-chave: Cateter venoso central, Hidrotórax, Alça, Mau posicionamento

  15. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  16. Mesenteric vascular occlusion: Comparison of ancillary CT findings between arterial and venous occlusions and independent CT findings suggesting life-threatening events

    International Nuclear Information System (INIS)

    Wong, Yon Cheong; Wu, Cheng Hsien; Wang, Li Jen; Chen, Huan Wu; Lin, Being Chuan; Huang, Chen Chih

    2013-01-01

    To compare the ancillary CT findings between superior mesenteric artery thromboembolism (SMAT) and superior mesenteric vein thrombosis (SMVT), and to determine the independent CT findings of life-threatening mesenteric occlusion. Our study was approved by the institution review board. We included 43 patients (21 SMAT and 22 SMVT between 1999 and 2008) of their median age of 60.0 years, and retrospectively analyzed their CT scans. Medical records were reviewed for demographics, management, surgical pathology diagnosis, and outcome. We compared CT findings between SMAT and SMVT groups. Multivariate analysis was conducted to determine the independent CT findings of life-threatening mesenteric occlusion. Of 43 patients, 24 had life-threatening mesenteric occlusion. Death related to mesenteric occlusion was 32.6%. A thick bowel wall (p < 0.001), mesenteric edema (p < 0.001), and ascites (p = 0.009) were more frequently associated with SMVT, whereas diminished bowel enhancement (p = 0.003) and paralytic ileus (p = 0.039) were more frequent in SMAT. Diminished bowel enhancement (OR = 20; p = 0.007) and paralytic ileus (OR = 16; p = 0.033) were independent findings suggesting life-threatening mesenteric occlusion. The ancillary CT findings occur with different frequencies in SMAT and SMVT. However, the independent findings indicating life-threatening mesenteric occlusion are diminished bowel wall enhancement and paralytic ileus.

  17. Venous leg ulcers

    Science.gov (United States)

    2008-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri

  18. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  19. Pattern of venous collateral development after splenic vein occlusion in an extended Whipple procedure : comparison with collateral vein pattern in cases of sinistral portal hypertension.

    Science.gov (United States)

    Strasberg, Steven M; Bhalla, Sanjeev; Sanchez, Luis A; Linehan, David C

    2011-11-01

    The risks of developing sinistral portal hypertension as a result of occlusion of the splenic vein close to its termination during a Whipple procedure are unclear. Our purpose was to compare the pattern of venous collateral development after splenic vein ligation in an extended Whipple procedure with the pattern of collateral development in cases of sinistral portal hypertension. Five patients underwent an extended Whipple procedure in which the splenic vein was divided and not reconstructed. Six to eight months later detailed mapping of venous return from the spleen was determined by contrast-enhanced multidetector computed tomography or in one case by 3D contrast-enhanced MRI. Spleen size and length of residual patent splenic vein were also measured. The literature on sinistral portal hypertension was evaluated to ascertain whether the venous collateral pattern in cases of left-sided portal hypertension was similar to the pattern that developed when the splenic vein was ligated at its termination in the Whipple procedure. A length of splenic vein remained patent in all five patients, measuring 4.5 to 11.5 cm from the spleen. Splenomegaly did not develop. Blood returned from the spleen by multiple collaterals including collaterals in the omentum and mesocolon. These types of collaterals do not develop in sinistral portal hypertension, nor is residual patent splenic vein seen. Ligation of the splenic vein close to its termination in five patients resulted in a pattern of venous return different from patients that have developed left-sided portal hypertension.

  20. Sodium-hydrogen exchange in erythrocytes of patients with acute deep venous thromboses.

    Science.gov (United States)

    Polykarpov, S A; Orlov, S N

    1992-05-15

    The rate of delta microH(+)-induced Na/H-exchange in erythrocytes of patients with occlusive and with floating types of acute deep venous thromboses, and in control volunteers, was estimated. In patients with occlusive thrombi Na/H-exchange was revealed to be fourfold higher in comparison with patients with floating thrombi and with controls, while no difference was observed between the two latter groups.

  1. Central retinal artery occlusion in the 9 years old girl (Clinical case report

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2013-01-01

    Full Text Available 9 years old girl was admitted to the Ophthalmological Department of Morozov Pediatric City Clinical Hospital with sudden persistent painless loss of vision of the left eye. Other organs and systems were without any changes. After ophthalmological examination (OS — white edema of central and peripapillar retina, a cherry red spot at the fovea the diagnosis of central retinal artery occlusion OS was formed, and treatment was started immediately. CRAO practically does not occur in pediatric ophthalmological practice. Therefore this clinical case can be of interest to clinicians and pediatric ophthalmologists.

  2. Central retinal artery occlusion in the 9 years old girl (Clinical case report

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2014-07-01

    Full Text Available 9 years old girl was admitted to the Ophthalmological Department of Morozov Pediatric City Clinical Hospital with sudden persistent painless loss of vision of the left eye. Other organs and systems were without any changes. After ophthalmological examination (OS — white edema of central and peripapillar retina, a cherry red spot at the fovea the diagnosis of central retinal artery occlusion OS was formed, and treatment was started immediately. CRAO practically does not occur in pediatric ophthalmological practice. Therefore this clinical case can be of interest to clinicians and pediatric ophthalmologists.

  3. Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

    Science.gov (United States)

    Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri

    2015-11-01

    Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.

  4. Celiac artery stenosis/occlusion treated by interventional radiology

    International Nuclear Information System (INIS)

    Ikeda, Osamu; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki

    2009-01-01

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  5. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  6. Pulmonary veno-occlusive disease Report of case and revision of the literature

    International Nuclear Information System (INIS)

    Jimenez Q, Andres; Palacios, Diana; Camacho D, Fidel

    2008-01-01

    The real incidence of veno-occlusive pulmonary disease (VOPD) is unknown because it is largely under diagnosed or is not classified as primary pulmonary hypertension, being in fact a variant of the primary disease, primarily affecting post-capillary pulmonary vasculature. It is also known as isolated pulmonary venous sclerosis, obstructive disease of the pulmonary veins or primary pulmonary hypertension of the venous type. VOPD is the result of multiple aggressors associated to a great variety of risk factors. The diagnosis of the disease requires clinical, radiological and pathological features. Vasodilators, immunosuppressants, anticoagulation and oxygen have been proposed as treatments with a poor prognosis, and with reported survival limited by the scarce reporting of cases. We report a case of veno-occlusive pulmonary disease which was diagnosed in this institution.

  7. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    Science.gov (United States)

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  8. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  9. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  10. Central and peripheral venous lines-associated blood stream infections in the critically ill surgical patients.

    Science.gov (United States)

    Ugas, Mohamed Ali; Cho, Hyongyu; Trilling, Gregory M; Tahir, Zainab; Raja, Humaera Farrukh; Ramadan, Sami; Jerjes, Waseem; Giannoudis, Peter V

    2012-09-04

    Critically ill surgical patients are always at increased risk of actual or potentially life-threatening health complications. Central/peripheral venous lines form a key part of their care. We review the current evidence on incidence of central and peripheral venous catheter-related bloodstream infections in critically ill surgical patients, and outline pathways for prevention and intervention. An extensive systematic electronic search was carried out on the relevant databases. Articles were considered suitable for inclusion if they investigated catheter colonisation and catheter-related bloodstream infection. Two independent reviewers engaged in selecting the appropriate articles in line with our protocol retrieved 8 articles published from 1999 to 2011. Outcomes on CVC colonisation and infections were investigated in six studies; four of which were prospective cohort studies, one prospective longitudinal study and one retrospective cohort study. Outcomes relating only to PICCs were reported in one prospective randomised trial. We identified only one study that compared CVC- and PICC-related complications in surgical intensive care units. Although our search protocol may not have yielded an exhaustive list we have identified a key deficiency in the literature, namely a paucity of studies investigating the incidence of CVC- and PICC-related bloodstream infection in exclusively critically ill surgical populations. In summary, the diverse definitions for the diagnosis of central and peripheral venous catheter-related bloodstream infections along with the vastly different sample size and extremely small PICC population size has, predictably, yielded inconsistent findings. Our current understanding is still limited; the studies we have identified do point us towards some tentative understanding that the CVC/PICC performance remains inconclusive.

  11. Hypoplastic left heart syndrome and pulmonary veno-occlusive disease in an infant.

    Science.gov (United States)

    D'Souza, Marise; Vergales, Jeffrey; Jayakumar, K Anitha

    2013-01-01

    This report describes an infant with heterotaxy syndrome and severe hypoplasia of the left heart who presented with profound cyanosis at birth despite a large patent ductus arteriosus. Pulmonary venous return was difficult to demonstrate by echocardiography. Angiography showed total anomalous pulmonary venous return via a plexus that drained through the paravertebral veins and bilateral superior vena cavae. Autopsy confirmed these findings, and histopathology demonstrated severe occlusive changes within the pulmonary veins.

  12. Maximizing mandibular prosthesis stability utilizing linear occlusion, occlusal plane selection, and centric recording.

    Science.gov (United States)

    Williamson, Richard A; Williamson, Anne E; Bowley, John; Toothaker, Randy

    2004-03-01

    The stability of mandibular complete dentures may be improved by reducing the transverse forces on the denture base through linear (noninterceptive) occlusion, selecting an occlusal plane that reduces horizontal vectors of force at occlusal contact, and utilizing a central bearing intraoral gothic arch tracing to record jaw relations. This article is intended to acquaint the reader with one technique for providing stable complete denture prostheses using the aforementioned materials, devices, and procedures.

  13. Catastrophic Antiphospholipid Syndrome Presenting as Bilateral Central Retinal Artery Occlusions

    Directory of Open Access Journals (Sweden)

    Steven S. Saraf

    2015-01-01

    Full Text Available A previously healthy 22-year-old African American woman presented with bilateral vision loss associated with headache. Her ocular examination was significant for bilateral retinal arterial “boxcarring,” retinal whitening, retinal hemorrhages, and cherry red spots. She was diagnosed with bilateral central retinal artery occlusions and was hospitalized due to concomitant diagnosis of stroke and hypercoagulable state. She was also found to be in heart failure and kidney failure. Rheumatology was consulted and she was diagnosed with catastrophic antiphospholipid syndrome in association with systemic lupus erythematosus. Approximately 7 months after presentation, the patient’s vision improved and remained stable at 20/200 and 20/80.

  14. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2015-01-01

    Full Text Available Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforation, arrhythmias, sepsis, and pulmonary embolism. A 12-year-old female received chemotherapy for acute lymphocytic leukemia through a central venous port implanted into her right subclavian area. The patient completed chemotherapy without complications 6 months ago. Venous port was accidentally fractured during its removal. Chest radiographs of the patient revealed intracardiac catheter fragment extending from the right subclavian to the right atrium (RA and looping in the RA. The procedure was performed under ketamine and midazolam anesthesia and fluoroscopic guidance using a percutaneous femoral vein approach. A snare with triple loops (10 mm in diameter was used to successfully retrieve the catheter fragments without any complication. Percutaneous transcatheter retrieval of catheter fragments is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters and can be chosen before resorting to surgery, which has potential risks related to thoracotomy, cardiopulmonary bypass, and general anesthesia.

  15. Dexamethasone Implant (Ozurdex in a Case with Unilateral Simultaneous Central Retinal Vein and Branch Retinal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Taylan Ozturk

    2015-02-01

    Full Text Available Simultaneous branch retinal artery and vein occlusion is a rare condition that may cause severe visual loss, and its treatment is often unrewarding. Herein, we report a case with simultaneous central retinal vein and branch retinal artery occlusion; it was successfully treated with a single dexamethasone intravitreal implant. The affected eye attained a visual acuity level of 20/25 from the visual acuity of hand motions at presentation with a residual, but relatively diminished, altitudinal scotoma during a follow-up period of 6 months.

  16. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  17. Significance of venous anastomosis in fingertip replantation.

    Science.gov (United States)

    Hattori, Yasunori; Doi, Kazuteru; Ikeda, Keisuke; Abe, Yukio; Dhawan, Vikas

    2003-03-01

    Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.

  18. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  19. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  20. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Takeuchi, Yoshito; Arai, Yasuaki; Sugimura, Kazuro

    2013-01-01

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  2. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  3. Central venous catheter (CVC) removal for patients of all ages with candidaemia

    DEFF Research Database (Denmark)

    Janum, Susanne; Afshari, Arash

    2016-01-01

    BACKGROUND: Candida bloodstream infections most often affect those already suffering serious, potentially life-threatening conditions and often cause significant morbidity and mortality. Most affected persons have a central venous catheter (CVC) in place. The best CVC management in these cases has......, GRADE - Grades of Recommendation, Assessment, Development and Evaluation Working Group). AUTHORS' CONCLUSIONS: Despite indications from observational studies in favour of early catheter removal, we found no eligible RCTs or quasi-RCTs to support these practices and therefore could draw no firm...

  4. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    Science.gov (United States)

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  5. Acesso venoso central guiado por ultrassom: qual a evidência? Ultrasound-guided central venous catheterization: what is the evidence?

    Directory of Open Access Journals (Sweden)

    Felippe Leopoldo Dexheimer Neto

    2011-06-01

    Full Text Available Recentemente, órgãos internacionais de qualidade em saúde passaram a recomendar o uso de orientação ultrassonográfica para punções venosas centrais. O objetivo deste artigo foi revisar as evidências fundamentando tais recomendações. Foi revisada a literatura no MEDLINE, PubMed e SCIELO com os seguintes termos (MeSH: acesso venoso central, ultrassom e adultos. A pesquisa realizada em 24/09/2010, com seleção de metanálises, ensaios clínicos randomizados e revisões, encontrou 291 artigos. Os 21 artigos mais importantes foram utilizados para a confecção desta revisão. A veia jugular interna é o local mais estudado para punções guiadas por ultrassonografia, com metanálises demonstrando menor risco relativo de falha e de complicações. Além disso, o maior ensaio clínico randomizado disponível também demonstrou redução na incidência de infecções de corrente sanguínea associadas aos cateteres venosos centrais. Poucos estudos existem com relação à punção da veia subclávia, porém o uso do ultrassom mostrou-se benéfico em duas metanálises (mas com um número pouco expressivo de pacientes. Quanto ao sítio venoso femoral, há apenas um ensaio clínico randomizado (20 pacientes, o qual obteve resultados positivos. Em uma avaliação britânica de custo-efetividade, houve economia de recursos com o auxílio do ultrassom na realização das punções venosas nos diferentes sítios. Fortes evidências demonstram benefício com o auxílio ultrassonográfico para punção jugular interna. Embora o método pareça atraente para os demais sítios, ainda não há estudos suficientes que sustentem alguma recomendação.In recent years, international health quality assurance organizations have been recommending ultrasound guidance for central venous punctures. This article reviews the evidence behind these recommendations. The MEDLINE, PubMed and SCIELO databases were searched for the following MeSH terms: central venous

  6. Blood flow vs. venous pressure effects on filtration coefficient in oleic acid-injured lung.

    Science.gov (United States)

    Anglade, D; Corboz, M; Menaouar, A; Parker, J C; Sanou, S; Bayat, S; Benchetrit, G; Grimbert, F A

    1998-03-01

    On the basis of changes in capillary filtration coefficient (Kfc) in 24 rabbit lungs, we determined whether elevations in pulmonary venous pressure (Ppv) or blood flow (BF) produced differences in filtration surface area in oleic acid-injured (OA) or control (Con) lungs. Lungs were cyclically ventilated and perfused under zone 3 conditions by using blood and 5% albumin with no pharmacological modulation of vascular tone. Pulmonary arterial, venous, and capillary pressures were measured by using arterial, venous, and double occlusion. Before and during each Kfc-measurement maneuver, microvascular/total vascular compliance was measured by using venous occlusion. Kfc was measured before and 30 min after injury, by using a Ppv elevation of 7 cmH2O or a BF elevation from 1 to 2 l . min-1 . 100 g-1 to obtain a similar double occlusion pressure. Pulmonary arterial pressure increased more with BF than with Ppv in both Con and OA lungs [29 +/- 2 vs. 19 +/- 0.7 (means +/- SE) cmH2O; P Kfc (200 +/- 40 vs. 83 +/- 14%, respectively; P < 0.01) and microvascular/total vascular compliance ratio (86 +/- 4 vs. 68 +/- 5%, respectively; P < 0.01) increased more with BF than with Ppv. In conclusion, for a given OA-induced increase in hydraulic conductivity, BF elevation increased filtration surface area more than did Ppv elevation. The steep pulmonary pressure profile induced by increased BF could result in the recruitment of injured capillaries and could also shift downstream the compression point of blind (zone 1) and open injured vessels (zone 2).

  7. Venous intravasation: a potential pitfall of confirmatory hysterosalpingogram following essure hysteroscopic sterilization.

    Science.gov (United States)

    Chang, Michael C; Shim, John J

    2012-09-01

    Indications for hysterosalpingography (HSG) include evaluation of infertility, spontaneous abortions, postoperative evaluation of tubal ligation, pre-myomectomy evaluation, and more recently, evaluation of tubal occlusion after placement of the Essure Permanent Birth Control System. Here we report a case of venous intravasation during a routine post-Essure HSG, a phenomenon in which contrast transits from the uterine cavity, through the myometrium, and directly into draining pelvic veins. Venous intravasation is a potential pitfall in interpretation of HSGs.

  8. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  9. Central venous catheterization training: current perspectives on the role of simulation

    Science.gov (United States)

    Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher

    2018-01-01

    Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. PMID:29872360

  10. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  11. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  12. Simultaneous Iliac Vein Bovine Pericardial Patch Venoplasty and Creation of PTFE Lower Limb Arteriovenous Fistula Graft for Rescue Vascular Access.

    Science.gov (United States)

    Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun

    2016-10-01

    We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  14. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  15. Central venous pressure monitoring via peripherally or centrally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Sanfilippo, Filippo; Noto, Alberto; Martucci, Gennaro; Farbo, Marco; Burgio, Gaetano; Biasucci, Daniele G

    2017-07-14

    The central venous pressure (CVP) is the most commonly used static marker of preload for guiding fluid therapy in critically ill patients, though its usefulness remains controversial. Centrally inserted central catheters (CICCs) are the gold-standard devices for CVP monitoring but peripherally inserted central catheters (PICCs) may represent a valid alternative. We undertook a systematic review and meta-analysis with the aim to investigate whether the difference between PICC- and CICC-measured CVP is not significant. We searched for clinical studies published in PubMed and EMBASE databases from inception until December 21st 2016. We included studies providing data on paired and simultaneous CVP measurement from PICCs and CICCs. We conducted two analyses on the values of CVP, the first one according to the total number of CVP assessments, the second one considering the number of patients recruited. Four studies matched the inclusion criteria, but only three of them provided data for the meta-analyses. Both analyses showed non-significant differences between PICC-measured and CICC-measured CVP: 1489 paired simultaneous CVP assessments (MD 0.16, 95%CI -0.14, 0.45, p = 0.30) on a total of 57 patients (MD 0.22, 95%CI -1.46, 1.91, p = 0.80). Both analyses showed no heterogeneity (I2 = 0%). Available evidence supports that CVP monitoring with PICCs is accurate and reproduces similar values to those obtained from CICCs. The possibility to monitor CVP should not be used among clinical criteria for preferring a CICC over a PICC line.

  16. Association between isotretinoin use and central retinal vein occlusion in an adolescent with minor predisposition for thrombotic incidents: a case report

    Directory of Open Access Journals (Sweden)

    Labiris Georgios

    2009-02-01

    Full Text Available Abstract Introduction We report an adolescent boy with minimal pre-existing risk for thromboses who suffered central retinal vein occlusion associated with isotretinoin use for acne. To the best of our knowledge, this is the first well documented case of this association. Case presentation An otherwise healthy 17-year-old white man who was treated with systemic isotretinoin for recalcitrant acne was referred with central retinal vein occlusion in one eye. Although a detailed investigation was negative, DNA testing revealed that the patient was a heterozygous carrier of the G20210A mutation of the prothrombin gene. Despite the fact that this particular mutation is thought to represent only a minor risk factor for thromboses, it is probable that isotretinoin treatment greatly increased the risk of a vaso-occlusive incident in this patient. Conclusion Isotretinoin use may be associated with sight- and life-threatening thrombotic adverse effects even in young patients with otherwise minimal thrombophilic risk. Physicians should be aware of such potential dangers.

  17. Inner neural retina loss in central retinal artery occlusion.

    Science.gov (United States)

    Ikeda, Fumiko; Kishi, Shoji

    2010-09-01

    To report morphologic retinal changes and visual outcomes in acute and chronic central retinal artery occlusion (CRAO). We reviewed ten eyes of ten patients with CRAO (age, 65.3 ± 10.2 years) and measured retinal thicknesses at the central fovea and the perifovea using optical coherence tomography (OCT) over 8 ± 4 months. During the acute phase (within 10 days), the mean inner retinal thicknesses were 148% and 139% of normal values at 1 mm nasal and temporal to the fovea. They decreased to 22% and 11% of normal inner retinal thickness during the chronic phase (3 months or later). The retinal thickness at the perifovea decreased linearly until 3 months but was stable during the chronic phase. In contrast, the foveal thickness increased slightly in the acute phase but was equivalent to the normal level during the chronic phase. As a result of inner retinal atrophy, the foveal pit was shallow during the chronic phase. The final visual acuity was correlated positively with retinal thickness at the perifovea during the chronic CRAO phase. OCT showed that inner retinal necrosis with early swelling and late atrophy occurred in CRAO. The fovea and outer retina appeared to be excluded from ischemic change. The residual inner retina at the perifovea determined the final visual outcomes.

  18. Central venous device-related thrombosis as imaged with MDCT in oncologic patients: prevalence and findings

    International Nuclear Information System (INIS)

    Catalano, Orlando; Castelguidone, Elisabetta de Lutio di; Granata, Vincenza; D'Errico, Adolfo Gallipoli; Sandomenico, Claudia; Petrillo, Mario; Aprea, Pasquale

    2011-01-01

    Background: Venous thrombosis is a common occurrence in cancer patients, developing spontaneously or in combination with indwelling central venous devices (CVD). Purpose: To analyze the multidetector CT (MDCT) prevalence, appearance, and significance of catheter related thoracic venous thrombosis in oncologic patients and to determine the percentage of thrombi identified in the original reports. Material and Methods: Five hundred consecutive patients were considered. Inclusion criteria were: presence of a CVD; availability of a contrast-enhanced MDCT; and cancer history. Exclusion criteria were: direct tumor compression/infiltration of the veins; poor image quality; device tip not in the scanned volume; and missing clinical data. Seventeen (3.5%) out of the final 481 patients had a diagnosis of venous thrombosis. Results: Factors showing the highest correlation with thrombosis included peripherally-inserted CVD, right brachiocephalic vein tip location, patient performance status 3, metastatic stage disease, ongoing chemotherapy, and longstanding CVD. The highest prevalence was in patients with lymphoma, lung carcinoma, melanoma, and gynecologic malignancies. Eleven out of 17 cases had not been identified in the original report. Conclusion: CVD-related thrombosis is not uncommon in cancer patients and can also be observed in outpatients with a good performance status and a non-metastatic disease. Thrombi can be very tiny. Radiologists should be aware of the possibility to identify (or overlook) small thrombi

  19. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein

    OpenAIRE

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-01-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common caro...

  20. Open heart surgery for management of right auricular thrombus related to central venous catheterization.

    Science.gov (United States)

    Ribeiro, A F; Neto, I S; Maia, I; Dias, C

    2018-04-19

    Central venous catheters are widely used in critically ill patients; however, they are also associated with increased morbidity and mortality. The literature may underestimate the incidence of catheter-inducible right atrial thrombi that are asymptomatic but potentially life threatening. The recognized risk factors for its development include infections related to the catheter, endothelial injury secondary to mechanical and chemical damage induced by certain medications and infused fluids. The characteristics of the patient and the catheter, such as size, material, type, location and ease of insertion, as well as the duration of placement play an additional role. We report the case of a 38-year-old man, who developed an asymptomatic catheter-inducible right atrial thrombi requiring open heart surgery, after taking a central venous catheter for thirty-five days. The present case highlights existing limitations in making a correct and fast diagnosis, which should be anticipated in patients with multiple risk factors for thrombosis. Given the limited recommendations available, we consider that the most appropriate strategy should be individualized. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Body surface infrared thermometry in patients with central venous cateter-related infections.

    Science.gov (United States)

    Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio

    2015-01-01

    To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.

  2. Importance of blood cultures from peripheral veins in pediatric patients with cancer and a central venous line

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Rutkjaer, Cecilie

    2015-01-01

    When an infection is suspected in a child with cancer and a central venous line (CVL), cultures are often only obtained from the CVL and not from a peripheral vein (PV). This study was undertaken to evaluate the importance of concomitant blood cultures from the CVL and a PV....

  3. Predictors of Unattempted Central Venous Catheterization in Septic Patients Eligible for Early Goal-directed Therapy

    Directory of Open Access Journals (Sweden)

    David R. Vinson

    2014-02-01

    Full Text Available Introduction: Central venous catheterization (CVC can be an important component of the management of patients with severe sepsis and septic shock. CVC, however, is a time- and resource-intensive procedure associated with serious complications. The effects of the absence of shock or the presence of relative contraindications on undertaking central line placement in septic emergency department (ED patients eligible for early goal-directed therapy (EGDT have not been well described. We sought to determine the association of relative normotension (sustained systolic blood pressure >90 mmHg independent of or in response to an initial crystalloid resuscitation of 20 mL/kg, obesity (body mass index [BMI] ≥30, moderate thrombocytopenia (platelet count <50,000 per μL, and coagulopathy (international normalized ratio ≥2.0 with unattempted CVC in EGDT-eligible patients. Methods: This was a retrospective cohort study of 421 adults who met EGDT criteria in 5 community EDs over a period of 13 months. We compared patients with attempted thoracic (internal jugular or subclavian CVC with those who did not undergo an attempted thoracic line. We also compared patients with any attempted CVC (either thoracic or femoral with those who did not undergo any attempted central line. We used multivariate logistic regression analysis to calculate adjusted odd ratios (AORs. Results: In our study, 364 (86.5% patients underwent attempted thoracic CVC and 57 (13.5% did not. Relative normotension was significantly associated with unattempted thoracic CVC (AOR 2.6 95% confidence interval [CI], 1.6-4.3, as were moderate thrombocytopenia (AOR 3.9; 95% CI, 1.5-10.1 and coagulopathy (AOR 2.7; 95% CI, 1.3-5.6. When assessing for attempted catheterization of any central venous site (thoracic or femoral, 382 (90.7% patients underwent attempted catheterization and 39 (9.3% patients did not. Relative normotension (AOR 2.3; 95% CI, 1.2-4.5 and moderate thrombocytopenia (AOR 3.9; 95

  4. Peripheral Edema, Central Venous Pressure, and Risk of AKI in Critical Illness

    Science.gov (United States)

    Chen, Kenneth P.; Cavender, Susan; Lee, Joon; Feng, Mengling; Mark, Roger G.; Celi, Leo Anthony; Mukamal, Kenneth J.

    2016-01-01

    Background and objectives Although venous congestion has been linked to renal dysfunction in heart failure, its significance in a broader context has not been investigated. Design, setting, participants, & measurements Using an inception cohort of 12,778 critically ill adult patients admitted to an urban tertiary medical center between 2001 and 2008, we examined whether the presence of peripheral edema on admission physical examination was associated with an increased risk of AKI within the first 7 days of critical illness. In addition, in those with admission central venous pressure (CVP) measurements, we examined the association of CVPs with subsequent AKI. AKI was defined using the Kidney Disease Improving Global Outcomes criteria. Results Of the 18% (n=2338) of patients with peripheral edema on admission, 27% (n=631) developed AKI, compared with 16% (n=1713) of those without peripheral edema. In a model that included adjustment for comorbidities, severity of illness, and the presence of pulmonary edema, peripheral edema was associated with a 30% higher risk of AKI (95% confidence interval [95% CI], 1.15 to 1.46; Pedema was not significantly related to risk. Peripheral edema was also associated with a 13% higher adjusted risk of a higher AKI stage (95% CI, 1.07 to 1.20; Pedema were associated with 34% (95% CI, 1.10 to 1.65), 17% (95% CI, 0.96 to 1.14), 47% (95% CI, 1.18 to 1.83), and 57% (95% CI, 1.07 to 2.31) higher adjusted risk of AKI, respectively, compared with edema-free patients. In the 4761 patients with admission CVP measurements, each 1 cm H2O higher CVP was associated with a 2% higher adjusted risk of AKI (95% CI, 1.00 to 1.03; P=0.02). Conclusions Venous congestion, as manifested as either peripheral edema or increased CVP, is directly associated with AKI in critically ill patients. Whether treatment of venous congestion with diuretics can modify this risk will require further study. PMID:26787777

  5. An analysis of leukapheresis and central venous catheter use in the randomized, placebo controlled, phase 3 IMPACT trial of Sipuleucel-T for metastatic castrate resistant prostate cancer.

    Science.gov (United States)

    Flanigan, Robert C; Polcari, Anthony J; Shore, Neil D; Price, Thomas H; Sims, Robert B; Maher, Johnathan C; Whitmore, James B; Corman, John M

    2013-02-01

    Sipuleucel-T is an autologous cellular immunotherapy. We review the safety of the leukapheresis procedure required for sipuleucel-T preparation and complications related to venous catheter use in the randomized, placebo controlled phase 3 IMPACT (IMmunotherapy for ProstAte Cancer Trial) study (NCT 00065442). A total of 512 patients with asymptomatic or minimally symptomatic metastatic castrate resistant prostate cancer were enrolled in the study. All patients were scheduled to undergo 3 standard 1.5 to 2.0 blood volume leukapheresis procedures at 2-week intervals. Leukapheresis related adverse events and those related to venous catheter use were reviewed. Immune cell counts were examined throughout the treatment course. Of 512 enrolled patients 506 underwent 1 or more leukapheresis procedures and were included in this analysis. Adverse events were comparable between the sipuleucel-T and control arms. Leukapheresis related adverse events were primarily associated with transient hypocalcemia (39.3%). Most leukapheresis related adverse events (97%) were of mild/moderate intensity. Median white blood cell count and absolute monocyte and lymphocyte counts were stable and within normal ranges throughout the treatment course. Of all patients 23.3% had a central venous catheter placed primarily for leukapheresis. Patients with vs without a central venous catheter had a higher risk of infection potentially related to catheter use (11.9% vs 1.3%, p nervous system (5.9% vs 2.1%, p = 0.06). Adverse events related to leukapheresis are manageable and quickly reversible. The majority of patients can undergo leukapheresis without a central venous catheter. Central venous catheters are associated with an increased risk of infections and venous vascular events. Peripheral intravenous access should be used when feasible. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2011-01-01

    Shock therapy aims at increasing central venous oxygen saturation (ScvO2), which is a marker of inadequate oxygen delivery. In this issue of Critical Care, Textoris and colleagues challenge this notion by reporting that high levels of ScvO2 are associated with mortality in patients with septic sh...

  7. Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects

    Directory of Open Access Journals (Sweden)

    Łukasz Kalińczuk

    2016-05-01

    Full Text Available Introduction: Totally implantable venous access systems (TIVAS, Swan-Ganz (SG and central venous catheters (CVC allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. Aim : To present results of percutaneous retrieval of embolized fragments of central venous devices or knotted SG and review the procedural aspects with a series of detailed angiographies. Material and methods : Between January 2003 and December 2012 there were 14 (~0.025% successful retrievals in 13 patients (44 ±16 years, 15% females of embolized fragments of TIVAS (n = 10 or CVC (n = 1 or of dislodged guide-wires (n = 2 or knotted SG (n = 1. Results : Foreign bodies with the forward end located in the right ventricle (RV, as well as those found in the pulmonary artery (PA, often required repositioning with a pigtail catheter as compared to those catheter fragments which were located in the right atrium (RA and/or great vein and possessed an accessible free end allowing their direct ensnarement with the loop snare (57.0% (4/7 vs. 66.7% (2/3 vs. 0.0% (0/3; p = 0.074 respectively. Procedure duration was 2–3 times longer among catheters retrieved from the PA than among those with the forward edge located in the RV or RA (30 (18–68 vs. 13.5 (11–37 vs. 8 min (8–13; p = 0.054 respectively. The SG catheter knotted in the vena cava superior (VCS was encircled with the loop snare introduced transfemorally, subsequently cut at its skin entrance and then pulled down inside the 14 Fr vascular sheath. Conclusions : By using the pigtail catheter and the loop snare, it is feasible to retrieve centrally embolized fragments or knotted central venous access devices.

  8. Retinal oximetry during treatment of retinal vein occlusion by ranibizumab in patients with high blood pressure and dyslipidemia.

    Science.gov (United States)

    Keilani, C; Halalchi, A; Wakpi Djeugue, D; Regis, A; Abada, S

    2016-12-01

    In the present study, we examined retinal vascular oxygen saturation in patients with retinal vein occlusion (RVO), high blood pressure (HBP) and dyslipidemia, before and during intravitreal vascular endothelial growth factor (VEGF) injection (ranibizumab). We retrospectively reviewed the medical records of six patients with visual acuity (VA) reduced by macular edema (ME) secondary to RVO with HBP and dyslipidemia, who underwent intravitreal anti-VEGF injection between October 2014 and February 2015 in the department of ophthalmology of François-Quesnay Hospital at Mantes-la-Jolie (France). The main inclusion criterion was the presence of RVO with ME and decreased VA. The primary endpoint was improvement of retinal venous oxygen saturation in patients with RVO before and 3 months after intravitreal ranibizumab injection. Secondary outcomes were improvement of retinal arterial oxygen saturation, improvement of best-corrected visual acuity (BCVA) on the Early Treatment Diabetic Retinopathy Study (ETDRS) scale, regression of ME measured by the central macular thickness (CMT) in nm and studying the correlation between blood pressure (BP) and retinal venous oxygen saturation before and after ranibizumab. Six eyes of six patients were included. Before treatment, the mean (standard deviation [SD]) of the retinal venous saturation (%) was 38.1±14.2. Three months after the injections, the mean (SD) of the retinal venous saturation (%) increased statistically significantly 49.2±11 (P=0.03). In this study, retinal venous oxygen saturation in patients with RVO, HBP and dyslipidemia was partially normalized during intravitreal ranibizumab treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  10. Risk Factors for Central and Branch Retinal Vein Occlusion: A Meta-Analysis of Published Clinical Data

    Directory of Open Access Journals (Sweden)

    Petr Kolar

    2014-01-01

    Full Text Available Retinal vein occlusion (RVO is a major cause of vision loss. Of the two main types of RVO, branch retinal vein occlusion (BRVO is 4 to 6 times more prevalent than central retinal vein occlusion (CRVO. A basic risk factor for RVO is advancing age. Further risk factors include systemic conditions like hypertension, arteriosclerosis, diabetes mellitus, hyperlipidemia, vascular cerebral stroke, blood hyperviscosity, and thrombophilia. A strong risk factor for RVO is the metabolic syndrome (hypertension, diabetes mellitus, and hyperlipidemia. Individuals with end-organ damage caused by diabetes mellitus and hypertension have greatly increased risk for RVO. Socioeconomic status seems to be a risk factor too. American blacks are more often diagnosed with RVO than non-Hispanic whites. Females are, according to some studies, at lower risk than men. The role of thrombophilic risk factors in RVO is still controversial. Congenital thrombophilic diseases like factor V Leiden mutation, hyperhomocysteinemia and anticardiolipin antibodies increase the risk of RVO. Cigarette smoking also increases the risk of RVO as do systemic inflammatory conditions like vasculitis and Behcet disease. Ophthalmic risk factors for RVO are ocular hypertension and glaucoma, higher ocular perfusion pressure, and changes in the retinal arteries.

  11. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; Anand, Sarah; Hickner, Andy; Buist, Michael; Rogers, Mary Am; Saint, Sanjay; Flanders, Scott A

    2013-07-27

    Peripherally inserted central catheters (PICCs) are associated with an increased risk of venous thromboembolism. However, the size of this risk relative to that associated with other central venous catheters (CVCs) is unknown. We did a systematic review and meta-analysis to compare the risk of venous thromboembolism associated with PICCs versus that associated with other CVCs. We searched several databases, including Medline, Embase, Biosis, Cochrane Central Register of Controlled Trials, Conference Papers Index, and Scopus. Additional studies were identified through hand searches of bibliographies and internet searches, and we contacted study authors to obtain unpublished data. All human studies published in full text, abstract, or poster form were eligible for inclusion. All studies were of adult patients aged at least 18 years who underwent insertion of a PICC. Studies were assessed with the Newcastle-Ottawa risk of bias scale. In studies without a comparison group, the pooled frequency of venous thromboembolism was calculated for patients receiving PICCs. In studies comparing PICCs with other CVCs, summary odds ratios (ORs) were calculated with a random effects meta-analysis. Of the 533 citations identified, 64 studies (12 with a comparison group and 52 without) including 29 503 patients met the eligibility criteria. In the non-comparison studies, the weighted frequency of PICC-related deep vein thrombosis was highest in patients who were critically ill (13·91%, 95% CI 7·68-20·14) and those with cancer (6·67%, 4·69-8·64). Our meta-analysis of 11 studies comparing the risk of deep vein thrombosis related to PICCs with that related to CVCs showed that PICCs were associated with an increased risk of deep vein thrombosis (OR 2·55, 1·54-4·23, p<0·0001) but not pulmonary embolism (no events). With the baseline PICC-related deep vein thrombosis rate of 2·7% and pooled OR of 2·55, the number needed to harm relative to CVCs was 26 (95% CI 13-71). PICCs are

  12. Development of a middle cerebral artery occlusion model in the nonhuman primate and a safety study of i.v. infusion of human mesenchymal stem cells.

    Directory of Open Access Journals (Sweden)

    Masanori Sasaki

    Full Text Available Most experimental stroke research is carried out in rodents, but given differences between rodents and human, nonhuman primate (NHP models may provide a valuable tool to study therapeutic interventions. The authors developed a surgical method for transient occlusion of the M1 branch of middle cerebral artery (MCA in the African green monkey to evaluate safety aspects of intravenous infusion of mesenchymal stem cells (hMSCs derived from human bone marrow.The left Sylvian fissure was exposed by a small fronto-temporal craniotomy. The M1 branch of the MCA was exposed by microsurgical dissection and clipped for 2 to 4 hours. Neurological examinations and magnetic resonance imaging (MRI were carried out at regular post-operative course. hMSCs were infused 1 hour after reperfusion (clip release in the 3-hour occlusion model.During M1 occlusion, two patterns of changes were observed in the lateral hemisphere surface. One pattern (Pattern 1 was darkening of venous blood, small vessel collapse, and blood pooling with no venous return in cortical veins. Animals with these three features had severe and lasting hemiplegia and MRI demonstrated extensive MCA territory infarction. Animals in the second pattern (Pattern 2 displayed darkening of venous blood, small vessel collapse, and reduced but incompletely occluded venous flow and the functional deficit was much less severe and MRI indicated smaller infarction areas in brain. The severe group (Pattern 1 likely had less extensive collateral circulation than the less severe group (Pattern 2 where venous pooling of blood was not observed. The hMSC infused animals showed a trend for greater functional improvement that was not statistically significant in the acute phase and no additive negative effects.These results indicate inter-animal variability of collateral circulation after complete M1 occlusion and that hMSC infusion is safe in the developed NHP stroke model.

  13. Biofilm formation in long-term central venous catheters in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Fuursted, Kurt; Funch, Peter

    2012-01-01

    Taurolidine has demonstrated inhibition of biofilm formation in vitro. The aim of this study was to compare the effect of catheter locking with taurolidine vs heparin in biofilm formation in central venous catheters. Forty-eight children with cancer were randomized to catheter locking by heparin (n...... = 22) or taurolidine (n = 26), respectively. After removal, catheters were examined by standardized scanning electron microscopy to assess quantitative biofilm formation. Biofilm was present if morphologically typical structures and bacterial cells were identified. Quantitative and semi...... in the intraluminal biofilm formation and the rate of bacterial colonization detected by scanning electron microscopy in the two groups....

  14. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    OpenAIRE

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 mont...

  15. K time & maximum amplitude of thromboelastogram predict post-central venous cannulation bleeding in patients with cirrhosis: A pilot study

    Directory of Open Access Journals (Sweden)

    Chandra K Pandey

    2017-01-01

    Interpretation & conclusions: Our results show that the cut-off value for INR ≥2.6 and K time ≥3.05 min predict bleeding and MA ≥48.8 mm predicts non-bleeding in patients with cirrhosis undergoing central venous pressure catheter cannulation.

  16. Primary thromboprophylaxis for cancer patients with central venous catheters--a reappraisal of the evidence.

    LENUS (Irish Health Repository)

    Cunningham, M S

    2006-01-30

    Venous thromboembolism (VTE) is responsible for an estimated 25 000 deaths per annum in UK hospital practice. It is well established that many of these deaths could be prevented through the use of appropriate thromboprophylaxis. This issue is of particular relevance in oncology practice, where the risks of VTE and bleeding are both significantly higher than those observed in general medical patients. Cancer patients with in-dwelling central venous catheters (CVCs) are at particularly high risk of developing thrombotic complications. However, the literature has produced conflicting conclusions regarding the efficacy of using routine primary thromboprophylaxis in these patients. Indeed such is the level of confusion around this topic, that the most recent version of the American College of Chest Physicians (ACCP) guidelines published in 2004 actually reversed their previous recommendation (published in 2001). Nevertheless, minidose warfarin continues to be routinely used in many oncology centres in the UK. In this article, we have performed a systematic review of the published literature regarding the efficacy and the risks, associated with using thromboprophylaxis (either minidose warfarin or low-dose LMWH) in cancer patients with CVC. On the basis of this evidence, we conclude that there is no proven role for using such thromboprophylaxis. However, asymptomatic CVC-related venous thrombosis remains common, and further more highly powered studies of better design are needed in order to define whether specific subgroups of cancer patients might benefit from receiving thromboprophylaxis.

  17. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    Science.gov (United States)

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  18. Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients

    Science.gov (United States)

    Petrov, Irene Y.; Prough, Donald S.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock is a dangerous medical condition, in which blood flow cannot provide the necessary amount of oxygen to organs and tissues. Currently, its diagnosis and therapy decisions are based on hemodynamic parameters (heart rate, blood pressure, blood gases) and mental status of a patient, which all have low specificity. Measurement of mixed or central venous blood oxygenation via catheters is more reliable, but highly invasive and associated with complications. Our previous studies in healthy volunteers demonstrated that optoacoustic systems provide non-invasive measurement of blood oxygenation in specific vessels, including central veins. Here we report our first results of a clinical study in coronary artery bypass graft (CABG) surgery patients. We used a medical-grade OPO-based optoacoustic system developed in our laboratory to measure in real time blood oxygenation in the internal jugular vein (IJV) of these patients. A clinical ultrasound imaging system (GE Vivid e) was used for IJV localization. Catheters were placed in the IJV as part of routine care and blood samples taken via the catheters were processed with a CO-oximeter. The optoacoustic oxygenation data were compared to the CO-oximeter readings. Good correlation between the noninvasive and invasive measurements was obtained. The results of these studies suggest that the optoacoustic system can provide accurate, noninvasive measurements of central venous oxygenation that can be used for patients with circulatory shock.

  19. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  20. Retinal vein occlusion: pathophysiology and treatment options

    OpenAIRE

    Karia, Niral

    2010-01-01

    Niral KariaDepartment of Ophthalmology, Southend Hospital, Prittlewell Chase, Westcliff on Sea, Essex, United KingdomAbstract: This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.Keywords: central, hemispheric, branch, retinal vein occlusion, visual loss

  1. Use of cultivation-dependent and -independent techniques to assess contamination of central venous catheters: a pilot study

    Directory of Open Access Journals (Sweden)

    Høiby Niels

    2008-10-01

    Full Text Available Abstract Background Catheters are the most common cause of nosocomial infections and are associated with increased risk of mortality, length of hospital stay and cost. Prevention of infections and fast and correct diagnosis is highly important. Methods In this study traditional semiquantitative culture-dependent methods for diagnosis of bacteria involved in central venous catheter-related infections as described by Maki were compared with the following culture-independent molecular biological methods: Clone libraries, denaturant gradient gel electrophoresis, phylogeny and fluorescence in situ hybridization. Results In accordance with previous studies, the cultivation of central venous catheters from 18 patients revealed that S. epidermidis and other coagulase-negative staphylococci were most abundant and that a few other microorganisms such as P. aeruginosa and K. pneumoniae occasionally were found on the catheters. The molecular analysis using clone libraries and sequencing, denaturant gradient gel electrophoresis and sequencing provided several important results. The species found by cultivation were confirmed by molecular methods. However, many other bacteria belonging to the phyla Proteobacteria, Firmicutes, Actinobacteria and Bacteroidetes were also found, stressing that only a minor portion of the species present were found by cultivation. Some of these bacteria are known to be pathogens, some have not before been described in relation to human health, and some were not closely related to known pathogens and may represent new pathogenic species. Furthermore, there was a clear difference between the bacterial species found in biofilm on the external (exluminal and internal (luminal side of the central venous catheter, which can not be detected by Maki's method. Polymicrobial biofilms were observed on most of the catheters and were much more common than the cultivation-dependent methods indicated. Conclusion The results show that diagnosis

  2. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  3. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  4. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  5. Antiphospholipid Syndrome and Vascular Ischemic (Occlusive) Diseases: An Overview

    Science.gov (United States)

    2007-01-01

    Antiphospholipid syndrome (APS) is primarily considered to be an autoimmune pathological condition that is also referred to as "Hughes syndrome". It is characterized by arterial and/or venous thrombosis and pregnancy pathologies in the presence of anticardiolipin antibodies and/or lupus anticoagulant. APS can occur either as a primary disease or secondary to a connective tissue disorder, most frequently systemic lupus erythematosus (SLE). Damage to the nervous system is one of the most prominent clinical constellations of sequelae in APS and includes (i) arterial/venous thrombotic events, (ii) psychiatric features and (iii) other non-thrombotic neurological syndromes. In this overview we compare the most important vascular ischemic (occlusive) disturbances (VIOD) with neuro-psychiatric symptomatics, together with complete, updated classifications and hypotheses for the etio-pathogenesis of APS with underlying clinical and laboratory criteria for optimal diagnosis and disease management. PMID:18159581

  6. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness

    DEFF Research Database (Denmark)

    Eskesen, T G; Wetterslev, M; Perner, A

    2016-01-01

    PURPOSE: Central venous pressure (CVP) has been shown to have poor predictive value for fluid responsiveness in critically ill patients. We aimed to re-evaluate this in a larger sample subgrouped by baseline CVP values. METHODS: In April 2015, we systematically searched and included all clinical...

  7. Effect of body temperature on peripheral venous pressure measurements and its agreement with central venous pressure in neurosurgical patients.

    Science.gov (United States)

    Sahin, Altan; Salman, M Alper; Salman, A Ebru; Aypar, Ulka

    2005-04-01

    Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical settings. The effect of body temperature on PVP and its agreement with CVP in patients under general anesthesia are investigated in this study. Fifteen American Society of Anesthesiologists I-II patients undergoing elective craniotomy were included in the study. CVP, PVP, and core (Tc) and peripheral (Tp) temperatures were monitored throughout the study. A total of 950 simultaneous measurements of CVP, PVP, Tc, and Tp from 15 subjects were recorded at 5-minute intervals. The measurements were divided into low- and high-Tc and -Tp groups by medians as cutoff points. Bland-Altman assessment for agreement was used for CVP and PVP in all groups. PVP measurements were within range of +/-2 mm Hg of CVP values in 94% of the measurements. Considering all measurements, mean bias was 0.064 mm Hg (95% confidence interval -0.018-0.146). Corrected bias for repeated measurements was 0.173 +/- 3.567 mm Hg (mean +/- SD(corrected)). All of the measurements were within mean +/- 2 SD of bias, which means that PVP and CVP are interchangeable in our setting. As all the measurements were within 1 SD of bias when Tc was > or = 35.8 degrees C, even a better agreement of PVP and CVP was evident. The effect of peripheral hypothermia was not as prominent as core hypothermia. PVP measurement may be a noninvasive alternative for estimating CVP. Body temperature affects the agreement of CVP and PVP, which deteriorates at lower temperatures.

  8. Risk factors for central line-associated bloodstream infection in pediatric oncology patients with a totally implantable venous access port: A cohort study.

    Science.gov (United States)

    Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves

    2017-02-01

    Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.

  9. Elucidating the mechanism of posterior reversible encephalopathy syndrome: a case of transient blindness after central venous catheterization.

    Science.gov (United States)

    Rao, Neal M; Raychev, Radoslav; Kim, Doojin; Liebeskind, David S

    2012-11-01

    Posterior reversible encephalopathy syndrome (PRES) is a condition characterized by reversible symptoms including headache, visual disturbances, focal neurological deficits, altered mentation, and seizures. It has been associated with circumstances that may affect the cerebrovascular system, such as hypertension, eclampsia, and immunosuppression with calcineurin inhibitors. The underlying etiology of PRES has remained unclear; however, cerebrovascular autoregulatory dysfunction, hyperperfusion, and endothelial activation have been implicated. We describe a case of a young patient with lung transplant, who presented with headache, acute binocular blindness, and seizure immediately after infusion of saline through a peripherally inserted central catheter line, which inadvertently terminated cephalad in the left internal jugular vein, near the jugular foramen. Subsequent brain magnetic resonance imaging revealed vasogenic edematous lesions in a pattern consistent with PRES--a diagnosis supported by his constellation of symptoms, history of lung transplantation on tacrolimus immunosuppression, and relative hypertension. This is the first reported case describing the development of PRES after the insertion of a peripherally inserted central catheter line. The development of PRES in a typical high-risk patient immediately after cerebral venous outflow obstruction implicates the role of the cerebral venous system and provides potential insight into the mechanism of this disorder that remains of unclear pathogenesis.

  10. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    Science.gov (United States)

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Serious Gaming to Improve the Safety of Central Venous Catheter Placement

    Directory of Open Access Journals (Sweden)

    Daniel Katz

    2013-06-01

    Full Text Available Approximately 5 million central venous catheters (CVCs are placed by physicians annually in the United States, with a complication rate of 15%.1 Guidelines and recommendations are continually being established and updated regarding CVC placement.2 While much has been done regarding training the technical skills of CVC placement using part-task trainers (i.e., mannequins, successfully finding and cannulating a central vein is but one part of the process. In fact, many steps designed to prevent untoward complications involve non-technical skills which are perhaps more important in training practitioners to safely place CVCs. First in aviation and now in healthcare, practitioners are being trained in realistic and highly interactive simulated environments so they can learn not just technical skills , but the key management and non-technical steps which make their task safer.3 One modality being used to improve performance is video gaming simulation, or "serious gaming." Gaming as a learning tool is being increasingly utilized in health care fields and can lead to better skill-based outcomes.4 As such, we have developed a game based around the placement of CVCs that will be used as a new teaching modality in a pilot program for instructing residents in safe CVC placement.

  12. Individualized Ranibizumab Regimen Driven by Stabilization Criteria for Central Retinal Vein Occlusion

    DEFF Research Database (Denmark)

    Larsen, Michael; Waldstein, Sebastian M; Boscia, Francesco

    2016-01-01

    ischemia (exploratory analysis). RESULTS: At baseline, the mean BCVA was 53.0 letters and mean CRVO duration was 8.9 months (median, 2.4 months). Ranibizumab 0.5-mg treatment resulted in a statistically significant mean gain in BCVA from baseline at month 12 of 12.3 letters (standard deviation [SD], 16......PURPOSE: To assess the 12-month efficacy and safety profile of an individualized regimen of ranibizumab 0.5 mg driven by stabilization criteria in patients with macular edema secondary to central retinal vein occlusion (CRVO). DESIGN: A 24-month, prospective, open-label, single-arm, multicenter...... study. PARTICIPANTS: Three hundred fifty-seven patients. METHODS: Patients were treated with monthly ranibizumab 0.5-mg injections (minimum of 3 injections) until stable visual acuity (VA) was maintained for 3 consecutive months. Thereafter, ranibizumab 0.5 mg was dosed as needed if monthly monitoring...

  13. Metastatic Carcinoma of Unknown Primary Presenting as Jugular Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Prince Cheriyan Modayil

    2009-01-01

    Full Text Available Jugular venous thrombosis is unusual and is associated with central venous catheterisation, intravenous drug abuse and head and neck sepsis. It is rarely associated with malignancy. We report a case of metastatic carcinoma of unknown primary in a forty year old female which presented with jugular venous thrombosis. The discussion includes investigation and treatment options for this condition.

  14. Low central venous pressure with milrinone during living donor hepatectomy.

    Science.gov (United States)

    Ryu, H-G; Nahm, F S; Sohn, H-M; Jeong, E-J; Jung, C-W

    2010-04-01

    Maintaining a low central venous pressure (CVP) has been frequently used in liver resections to reduce blood loss. However, decreased preload carries potential risks such as hemodynamic instability. We hypothesized that a low CVP with milrinone would provide a better surgical environment and hemodynamic stability during living donor hepatectomy. Thirty-eight healthy adult liver donors were randomized to receive either milrinone (milrinone group, n = 19) or normal saline (control group, n = 19) infusion during liver resection. The surgical field was assessed using a four-point scale. Intraoperative vital signs, blood loss, the use of vasopressors and diuretics and postoperative laboratory data were compared between groups. The milrinone group showed a superior surgical field (p milrinone group required smaller amounts of vasopressors and less-frequent diuretics to maintain a low CVP. The milrinone group also showed a more rapid recovery pattern after surgery. Milrinone-induced low CVP improves the surgical field with less blood loss during living donor hepatectomy and also has favorable effects on intraoperative hemodynamics and postoperative recovery.

  15. A case of central retinal artery occlusion following embolization procedure for juvenile nasopharyngeal angiofibroma

    Science.gov (United States)

    Ramezani, Alireza; Haghighatkhah, Hamidreza; Moghadasi, Habibollah; Taheri, Morteza S; Parsafar, Hiva

    2010-01-01

    A 23-year-old male patient with right nasal Juvenile Nasopharyngeal Angiofibroma (JNA) developed Central Retinal Artery Occlusion (CRAO) during embolization of the tumor using polyvinyl alcohol particles before endoscopic excision. Classic CRAO management was initiated by an ophthalmologist after 12 h. Retrospective evaluation of the angiograms revealed a tiny communication between the external carotid and ophthalmic arteries which had not been noticed before embolization. During endoscopic excision, the tumor was found to originate extraordinarily from midline structures. It was concluded that CRAO might be a rare complication of JNA embolization. Careful preoperative angiographic evaluations to detect communicating arteries and immediate ophthalmologic consultation in case of developing visual symptoms during the procedure are necessary. PMID:20689199

  16. A case of central retinal artery occlusion following embolization procedure for juvenile nasopharyngeal angiofibroma

    Directory of Open Access Journals (Sweden)

    Ramezani Alireza

    2010-01-01

    Full Text Available A 23-year-old male patient with right nasal Juvenile Nasopharyngeal Angiofibroma (JNA developed Central Retinal Artery Occlusion (CRAO during embolization of the tumor using polyvinyl alcohol particles before endoscopic excision. Classic CRAO management was initiated by an ophthalmologist after 12 h. Retrospective evaluation of the angiograms revealed a tiny communication between the external carotid and ophthalmic arteries which had not been noticed before embolization. During endoscopic excision, the tumor was found to originate extraordinarily from midline structures. It was concluded that CRAO might be a rare complication of JNA embolization. Careful preoperative angiographic evaluations to detect communicating arteries and immediate ophthalmologic consultation in case of developing visual symptoms during the procedure are necessary.

  17. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    Science.gov (United States)

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  18. Central Venous Catheters and Bloodstream Infection During Induction Therapy in Children With Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Bergmann, Kristin; Hasle, Henrik; Asdahl, Peter

    2016-01-01

    The purpose of the study was to assess the risk of firsttime bloodstream infection (BSI) according to type of central venous catheter (CVC) during induction therapy in children with acute lymphoblastic leukemia (ALL). Patients eligible for our analysis were all newly diagnosed children with ALL......-negative blood isolates occurred more frequently in patients with a TE, and that lower incidences of BSI were detected in patients older than 9 years with a TE, and in patients with T-ALL. It is concluded that the type of CVC inserted at diagnosis has no impact upon the risk of BSI in patients with ALL...

  19. Venous access: options, approaches and issues

    International Nuclear Information System (INIS)

    Asch, M.R.

    2001-01-01

    Venous access is an essential part of medical practice. It is needed to obtain blood samples to make the diagnosis and to administer fluids or medicines as part of treatment. Although relatively new in the history of medicine, the placement and maintenance of the various venous access devices now occupies a significant portion of many vascular and interventional radiology practices. Thus, it is important to have a thorough understanding of these devices and their uses. The first long-term venous access devices were used in 1973. These were placed via a surgical cut-down on the subclavian vein. In 1982, the first subcutaneous implantable ports were described. These procedures were initially performed by surgeons, but over the last 5-10 years, both the insertion and management of these devices has shifted to interventional radiologists. Peripherally inserted central catheter (PICC) lines have almost completely supplanted the use of standard central lines (Fig. 1). A number of factors have facilitated this - namely, ready and less expensive room access, outpatient procedure and radiologists' accessibility and familiarity with image-guidance procedures and catheters and guide wires. (author)

  20. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  1. Risk factors for central venous catheter-related infections in a neonatal population – systematic review

    Directory of Open Access Journals (Sweden)

    Viviane Rosado

    2018-01-01

    Full Text Available Objective: This was a systematic review of the incidence density and risk factors for central venous catheter-related infections in a neonatal population. Data source: The MEDLINE, Embase, Cochrane, BDENF, SciELO, and LILACS databases were used without date or language restriction. Studies that analyzed risk factors for bloodstream infections in newborns were identified. Data synthesis: A total of 134 articles were found that met the eligibility criteria. Of these articles, 14 were selected that addressed risk factors for central venous catheter-related infection in neonates. Catheter-related bloodstream infections remain an important complication, as shown by the incidence rates reported in the studies included in this review. The observed risk factors indicate that low birth weight, prematurity, and longer catheter permanence are related to a higher incidence of bloodstream infections. It has been observed that low rates of catheter-related infections, i.e., close to zero, are already a reality in health institutions in developed countries, since they use infection surveillance and control programs. Conclusion: Catheter-related bloodstream infections still show high incidence density rates in developing countries. The authors emphasize the need for further longitudinal studies and the need for better strategies to prevent risk factors, aiming at the reduction of catheter-related infections. Resumo: Objetivo: Trata-se de uma revisão sistemática sobre a densidade de incidência e de fatores de risco para infecção associada a cateter venoso central em população neonatal. Fontes dos dados: Utilizou-se os bancos de dados Medline, Embase, Cochrane, Bdenf, Scielo, Lilacs, sem restrição de data ou de idioma. Identificaram-se os estudos que analisaram fatores de risco para infecção da corrente sanguínea em recém-nascidos. Síntese dos dados: Foram encontrados 134 artigos conforme os critérios de elegibilidade. Destes artigos, foram

  2. Venous Intravasation: A Potential Pitfall of Confirmatory Hysterosalpingogram Following Essure Hysteroscopic Sterilization

    OpenAIRE

    Chang, Michael C.; Shim, John J.

    2012-01-01

    Indications for hysterosalpingography (HSG) include evaluation of infertility, spontaneous abortions, postoperative evaluation of tubal ligation, pre-myomectomy evaluation, and more recently, evaluation of tubal occlusion after placement of the Essure Permanent Birth Control System. Here we report a case of venous intravasation during a routine post-Essure HSG, a phenomenon in which contrast transits from the uterine cavity, through the myometrium, and directly into draining pelvic veins. Ven...

  3. A pilot study and novel angiographic classification for superior sagittal sinus stenting in patients with non-thrombotic intracranial venous occlusive disease.

    Science.gov (United States)

    Raper, Daniel M S; Buell, Thomas J; Ding, Dale; Pomeraniec, I Jonathan; Crowley, R Webster; Liu, Kenneth C

    2018-01-01

    Safety and efficacy of superior sagittal sinus (SSS) stenting for non-thrombotic intracranial venous occlusive disease (VOD) is unknown. The aim of this retrospective cohort study is to evaluate outcomes after SSS stenting. We evaluated an institutional database to identify patients who underwent SSS stenting. Radiographic and clinical outcomes were analyzed and a novel angiographic classification of the SSS was proposed. We identified 19 patients; 42% developed SSS stenosis after transverse sinus stenting. Pre-stent maximum mean venous pressure (MVP) in the SSS of 16.2 mm Hg decreased to 13.1 mm Hg after stenting (p=0.037). Preoperative trans-stenosis pressure gradient of 4.2 mm Hg decreased to 1.5 mm Hg after stenting (pSSS stenosis distal to the stent construct was noted. Improvement in headache, tinnitus, and visual obscurations was reported by 66.7%, 63.6%, and 50% of affected patients, respectively, at mean follow-up of 5.2 months. We divided the SSS into four anatomically equal segments, numbered S1-S4, from the torcula to frontal pole. SSS stenosis typically occurs in the S1 segment, and the anterior extent of SSS stents was deployed at the S1-S2 junction in all but one case. SSS stenting is reasonably safe, may improve clinical symptoms, and significantly reduces maximum MVP and trans-stenosis pressure gradients in patients with VOD with SSS stenosis. The S1 segment is most commonly stenotic, and minimum pressure gradients for symptomatic SSS stenosis may be lower than for transverse or sigmoid stenosis. Additional studies and follow-up are necessary to better elucidate appropriate clinical indications and long-term efficacy of SSS stenting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  5. A case of Churg-Strauss syndrome and central retinal artery occlusion with good visual recovery

    Directory of Open Access Journals (Sweden)

    Yuki Kamata

    2013-01-01

    Full Text Available Here we report a case of Churg-Strauss syndrome (CSS and central retinal artery occlusion (CRAO, with good visual recovery. A 58-year-old Japanese man with CSS experienced acute painless loss of vision in his right eye. CRAO was diagnosed by fundoscopic findings (retinal whitening with a cherry-red spot. Steroid pulse therapy (methylprednisolone at 1 g daily for 3 days followed by combined treatment with prednisolone (30 mg/day and cyclophosphamide (150 mg/day was administered; his visual acuity recovered to 20/30 in 1 month, and no recurrence has occurred for 1 year. Steroid pulse therapy may be effective for CRAO in CSS patients.

  6. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    International Nuclear Information System (INIS)

    Desai, Shamit S.; Konanur, Meghana; Foltz, Gretchen; Malaisrie, S. Chris; Resnick, Scott

    2016-01-01

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period

  7. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu [Northwestern Memorial Hospital, Department of Radiology (United States); Konanur, Meghana [Northwestern University Feinberg School of Medicine (United States); Foltz, Gretchen [Mallinckrodt Institute of Radiology at Washington University, Interventional Radiology (United States); Malaisrie, S. Chris [Northwestern Memorial Hospital, Department of Cardiothoracic Surgery (United States); Resnick, Scott, E-mail: sresnick@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology, Interventional Radiology, Northwestern Memorial Hospital (United States)

    2016-03-15

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.

  8. Primary Stenting Is Not Necessary in Benign Central Venous Stenosis.

    Science.gov (United States)

    Rangel, Lynsey E; Lyden, Sean P; Clair, Daniel G

    2018-01-01

    The aim of this study is to evaluate central venous stenosis (CVS) etiologies and presentation within a vascular surgery practice. We evaluated endovascular treatment modalities and the patency rates of our interventions. Five-year retrospective review of endovascular intervention for CVS. Patient demographics, medical comorbidities, and variables were collected including etiology, indwelling device, previous upper extremity (UE) deep venous thrombosis, long-term UE indwelling device (defined as >30 days), malignancy status, hypercoagulable disorders, history of radiation or mediastinal fibrosis or masses, and anticoagulation and/or antiplatelet therapy. Follow-up variables included symptoms, imaging, and anticoagulation and/or antiplatelet utilization. Living patients without recent follow-up were contacted with a telephone survey regarding current symptoms. Patency was evaluated by imaging or clinically by recurrence of signs or symptoms through January 2016. A total of 61 patients underwent attempted endovascular CVS interventions from January 2007 to 2013. Forty-seven (83%) patients had successful interventions. There were 22 (36%) end-stage renal disease (ESRD) patients. The primary etiology in 79% of patients was benign CVS secondary to an indwelling device. Eighty-nine percent of the interventions were primary angioplasty (PTA). The overall primary patency rates at 6, 12, and 24 months were 49%, 34%, and 24%, respectively. Secondary patency rates at 6, 12, and 24 months were 97%, 93%, and 88%, respectively. There were no statistical differences in demographics or outcomes in patients treated successfully with PTA or those requiring stenting. There was no statistical difference in the patency rates between ESRD and non-ESRD patients. Previous interventions were not a predictor of loss of patency. Our study supported the rising trend of benign CVS predominantly secondary to indwelling devices. We demonstrated acceptable secondary patency with PTA alone

  9. Simultaneous central retinal artery occlusion and optic nerve vasculitis in Crohn disease

    Directory of Open Access Journals (Sweden)

    Razek Georges Coussa

    2017-04-01

    Conclusions and importance: To our knowledge, this is the first case of unilateral CRAO and bilateral optic nerve occlusive vasculitis in Crohn disease, which should be considered as an etiology of retinal vascular occlusive disorders especially in young patients. It is important for ophthalmologists to be aware of the ophthalmic risks associated with Crohn disease as aggressive treatment with systemic steroids and immunosuppressive agents is often needed.

  10. Work in progress. Transcatheter thermal venous occlusion: a new technique

    International Nuclear Information System (INIS)

    Rholl, K.S.; Rysavy, J.A.; Vlodaver, Z.; Cragg, A.H.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1982-01-01

    Diatrizoate (76%) contrast agent heated to 100 0 C was injected into the veins of dogs and one human volunteer for the nonsurgical occlusion of the vessels. Follow-up venograms and histologic examinations, at intervals varying from one day to four weeks later, revealed thrombosis of the injected veins in all animals. Thrombosis occurred one to five days after injection of contrast agent. The authors conclude that hot contrast medium is a safe and convenient agent for inducing thrombosis. It is much easier to use than mechanical devices, tissue glues, and plastics, which involve complex procedures and specialized equipment. In contrast to other sclerosing agents, hot contrast agent is rapidly converted into a nonsclerosing agent by cooling. The new technique allows a more controlled thremal injury to the vascular wall and is under fluoroscopic control

  11. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  12. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  13. Lower body positive pressure application with an antigravity suit in acute carotid occlusion.

    Science.gov (United States)

    Berthet, Karine; Lukaszewicz, Anne Claire; Bousser, Marie-Germaine; Payen, Didier

    2010-04-01

    The challenge in acute stroke is still to reperfuse as early as possible the ischemic territory. Since fibrinolytic therapies have a limited window with potential risk of bleeding, having a nonpharmacologic mean to recruit vessels in area surrounding necrosis might be useful. We propose here to use antigravity suit inflated at "venous" pressure levels to shift blood towards thoracic and brain territories. We report two cases of spectacular clinical recovery after acute carotid occlusion.

  14. Popliteal Venous Aneurysm: A Rare Cause of Recurrent Pulmonary Emboli and Limb Swelling

    International Nuclear Information System (INIS)

    Russell, David A.; Robinson, Graham J.; Johnson, Brian F.

    2008-01-01

    Popliteal venous aneurysm is a rare cause of recurrent pulmonary embolism, although the true incidence of aneurysm is probably underestimated. One-third of patients suffer further embolic events despite therapeutic anticoagulation. We report the case of a 59-year-old male who presented with recurrent PEs over a period of 12 years despite anticoagulation therapy. A thrombophilia screen and abdominal ultrasound were normal at that time. He reattended with recurrent pulmonary emboli, left calf swelling, and a mass in his left popliteal fossa causing limitation of knee movement. Venous duplex and MRI of his popliteal fossa demonstrated a thrombosed true popliteal venous aneurysm with popliteal and superficial femoral vein occlusion. In view of the mass effect we proceeded to surgical excision of his aneurysm after prophylactic placement of an IVC filter. The patient regained normal knee function with intensive inpatient physiotherapy. He has been recommenced on lifelong anticoagulant. The presentation, investigation, and management of the condition are briefly discussed. We suggest that a bilateral lower limb duplex is performed to exclude venous aneurysm in all patients presenting with pulmonary embolism in which an underlying source cannot otherwise be identified and no thrombophilic tendency is detected.

  15. Veno occlusive disease: Update on clinical management

    Science.gov (United States)

    Senzolo, M; Germani, G; Cholongitas, E; Burra, P; Burroughs, AK

    2007-01-01

    Hepatic veno-occlusive disease is a clinical syndrome characterized by hepatomegaly, ascites, weight gain and jaundice, due to sinusoidal congestion which can be caused by alkaloid ingestion, but the most frequent cause is haematopoietic stem cell transplantation (STC) and is also seen after solid organ transplantation. The incidence of veno occlusive disease (VOD) after STC ranges from 0 to 70%, but is decreasing. Survival is good when VOD is a mild form, but when it is severe and associated with an increase of hepatic venous pressure gradient > 20 mmHg, and mortality is about 90%. Prevention remains the best therapeutic strategy, by using non-myeloablative conditioning regimens before STC. Prophylactic administration of ursodeoxycholic acid, being an antioxidant and antiapoptotic agent, can have some benefit in reducing overall mortality. Defibrotide, which has pro-fibrinolytic and antithrombotic properties, is the most effective therapy; decompression of the sinusoids by a transjugular intrahepatic portosystemic shunt (TIPS) can be tried, especially to treat VOD after liver transplantation and when multiorgan failure (MOF) is not present. Liver transplantation can be the last option, but can not be considered a standard rescue therapy, because usually the concomitant presence of multiorgan failure contraindicates this procedure. PMID:17663504

  16. Guidewire retention following central venous catheterisation: a human factors and safe design investigation.

    Science.gov (United States)

    Horberry, Tim; Teng, Yi-Chun; Ward, James; Patil, Vishal; Clarkson, P John

    2014-01-01

    Central Venous Catheterisation (CVC) has occasionally been associated with cases of retained guidewires in patients after surgery. In theory, this is a completely avoidable complication; however, as with any human procedure, operator error leading to guidewires being occasionally retained cannot be fully eliminated. The work described here investigated the issue in an attempt to better understand it both from an operator and a systems perspective, and to ultimately recommend appropriate safe design solutions that reduce guidewire retention errors. Nine distinct methods were used: observations of the procedure, a literature review, interviewing CVC end-users, task analysis construction, CVC procedural audits, two human reliability assessments, usability heuristics and a comprehensive solution survey with CVC end-users. The three solutions that operators rated most highly, in terms of both practicality and effectiveness, were: making trainees better aware of the potential guidewire complications and strongly emphasising guidewire removal in CVC training, actively checking that the guidewire is present in the waste tray for disposal, and standardising purchase of central line sets so that differences that may affect chances of guidewire loss is minimised. Further work to eliminate/engineer out the possibility of guidewires being retained is proposed.

  17. A comparison between two types of central venous catheters in the prevention of catheter-related infections: the importance of performing all the relevant cultures

    NARCIS (Netherlands)

    van Vliet, J.; Leusink, J.A.; de Jongh, B.M.; de Boer, A.

    2001-01-01

    Objective: to determine the efficacy of double-lumen central venous catheters coated with chlorhexidine and silver-sulfadiazine in reducing the incidence of catheter-related infections. Design: a randomized controlled trial. Setting: medical-surgical intensive care unit of a 600-bed teaching

  18. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    Science.gov (United States)

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  19. Risk factors for venous port migration in a single institute in Taiwan

    OpenAIRE

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-01

    Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiw...

  20. [Hypercoagulable workup in ophthalmology. When and what].

    Science.gov (United States)

    Muñoz-Negrete, F J; Casas-Lleras, P; Pérez-López, M; Rebolleda, G

    2009-07-01

    Most ophthalmologic disorders secondary to hypercoagulabe state are due to the confluence of congenital and adquired factors. A systematic workup is mandatory. Most of congenital coagulation disorders cause venous trombosis and are inherited autosomal dominantly. In order of frequency these are factor V Leiden mutation (activated protein C resistance), G20210A mutation of the prothrombin gen and protein C, protein S, and antithrombin III deficiencies. Sickle cell anemia can determine arerial and venous thrombosis. In relation with arterial occlusion, the markers most frequently involved are homcysteine fasting levels and the markers of antiphospholipid antibody syndrome. Both of them can also determine venous thrombosis. Several acquired factors can lead to hypoercoagulable state, especially hyperhomocysteinemia, antiphospholipid antibody syndrome, hepatic disease, alcohol and tobacco intake, oral contraceptives, immobilization, surgeries and malignancies. In central venous occlusion is only necessary to rule out hyperhomocysteinemia and antiphospholipid antibody syndrome in young patients without known risk factors. In central artery occlusion, hypercoagulable workup is only recommended for patients less than 50 years-old with unknown emboli source. In this cases protein C, protein S, and antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome will ruled out. In non arteritic ischemic optic neuropathy hypercoagulable work up is not necessary. In amaurosis fugax without known emboli source, it is recommended to rule out etiologies of arterial occlusion, especially antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome.

  1. Radiologists need to be aware of secondary central venous stenosis in patients with SAPHO syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Mizuho; Kanazawa, Hidenori; Shinozaki, Takeshi; Sugimoto, Hideharu [Jichi Medical University, Department of Radiology, Shimotsuke, Tochigi (Japan)

    2017-11-15

    We aimed to define central venous stenosis (CVS) caused by sternocostoclavicular hyperostosis as a feature of synovitis-acne-pustulosis-hyperostosis-osteitis (SAPHO) syndrome on routine contrast-enhanced computed tomography (CT) images. The relationship between SAPHO syndrome and CVS without venous thrombosis caused by anterior chest wall compression has not been investigated. Therefore, the present study evaluated CVS in patients with SAPHO syndrome at our hospital. We retrospectively reviewed contrast-enhanced CT images of ten patients with suspected or diagnosed SAPHO syndrome between January 2007 and November 2015. The patients were assessed by contrast-enhanced CT using 16-, 64- or 128-detector row scanners. Two radiologists independently assessed the presence of CVS or obstruction and SAPHO syndrome in a retrospective review of CT images. Six of the ten patients had findings of CVS with SAPHO syndrome. The mean diameter and patency rate at the site of CVS were 1.88 mm and 27.2%, respectively. Stenosis was more significant in terms of the mean diameter of CVS sites than of stenotic sites that crossed the anteroposterior vein (p < 0.05). Radiologists who routinely assess contrast-enhanced CT images should be aware that sternocostoclavicular hyperostosis with SAPHO syndrome could cause secondary CVS. (orig.)

  2. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  3. The modified pulse-spray method using Urokinase in subacute and chronic thrombotic arterial occlusion

    International Nuclear Information System (INIS)

    Kim, Youn Kil; Hahn, Seong Tae; Baek, Jee Hee; Kim, Choon Yul; Shinn, Kyung Sub

    1996-01-01

    To evaluate the effectiveness and safety of the modified pulse-spray method using Urokinase(UK) in subacute and chronic thrombotic arterial occlusion. Modified pulse-spray methods using UK were performed in seven patients with subacute (1 week-1month) to chronic (1month-5years) occlusive symptoms such as limb pain, claudication and impotence. Angiographic examination revealed thrombotic occlusion of the aorta, common iliac arteries, brachial arterio-venous hemodialysis graft and femoro-popliteal bypass graft. The patients underwent thrombolysis using modified pulse-spray and additional constant infusion of UK. In the presence of underlying stenosis or organized clots, balloon angioplasty or stent placement was performed. Complete lysis was obtained in five of seven patients. For initial lysis, the mean dose of UK was 420,000 units, and the mean modified pulse-spray time was 50 minutes. Mean total dose of UK and mean total time for complete lysis were 800,000 units and 161 minutes, respectively. Thrombolysis of the femoro-popliteal bypass graft failed due to severe occlusion of the distal anastomosis. Partial lysis was achieved in one patient with aorto-illac occlusion, but further thrombolysis was stopped due to bleeding at the puncture site. The modified pulse-spray method using UK is effective in treating subacute and chronic arterial thrombotic occlusion. It augments the speed, safety and efficacy of thrombolysis. When underlying stenosis or organized clots remain after thrombolysis, ballon angioplasty or stent placement would be helpful

  4. Portal venous perfusion steal causing graft dysfunction after orthotopic liver transplantation: serial imaging findings in a successfully treated patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Su; Chung, Yong Eun; Choi, Jin Young; Park, Mi Suk; Lim, Joon Seok; Kim, Myeong Jin; Kim, Hon Soul [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Sang Kyun [Dept. of Pathology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-01-15

    A 53-year-old male with hepatocellular carcinoma underwent orthotopic liver transplantation. Preoperative computed tomography revealed main portal vein luminal narrowing by flat thrombi and the development of cavernous transformation. On post-transplantation day 1, thrombotic portal venous occlusion occurred, and emergency thrombectomy was performed. Subsequent Doppler ultrasonography and contrast-enhanced ultrasonography confirmed the restoration of normal portal venous flow. The next day, however, decreased portal venous velocity was observed via Doppler ultrasonography, and serum liver enzymes and bilirubin levels remained persistently elevated. Direct portography identified massive perfusion steal through prominent splenorenal collateral veins. Stent insertion and balloon angioplasty of the portal vein were performed, and subsequent Doppler ultrasonography demonstrated normalized portal flow parameters. Afterwards, the serum liver enzymes and bilirubin levels rapidly normalized.

  5. Reversibility of retinal ischemia due to central retinal artery occlusion by hyperbaric oxygen

    Directory of Open Access Journals (Sweden)

    Hadanny A

    2016-12-01

    Full Text Available Amir Hadanny,1,2 Amit Maliar,1 Gregory Fishlev,1 Yair Bechor,1 Jacob Bergan,1 Mony Friedman,1 Isaac Avni,2,3 Shai Efrati1,2,4,5 1Sagol Center for Hyperbaric Medicine and Research, Assaf Harofeh Medical Center, Zerifin, Israel; 2Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; 3Opthalmology Department, Assaf Harofeh Medical Center, Zeirifin, Israel; 4Research and Development Unit, Assaf Harofeh Medical Center, Zerifin, Israel; 5Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel Purpose: Ischemic retinal damage can be reversed by hyperbaric oxygen therapy (HBOT as long as irreversible infarction damage has not developed. However, the time window till irreversible damage develops is still unknown. The study aim was to evaluate the effect of HBOT and determine possible markers for irreversible retinal damage.Materials and methods: Retrospective analysis of 225 patients treated with HBOT for central retinal artery occlusion (CRAO in 1999–2015. One hundred and twenty-eight patients fulfilled inclusion/exclusion criteria: age >18 years, symptoms <20 hours, and best-corrected visual acuity (BCVA <0.5 logMAR.Results: Time delay from symptoms to treatment was 7.8±3.8 hours. The BCVA was significantly improved after HBOT, from 2.14±0.50 to 1.61±0.78 (P<0.0001. The proportion of patients with clinically meaningful visual improvement was significantly higher in patients without cherry-red spot (CRS compared to patients with CRS at presentation (86.0% vs 57.6%, P<0.0001. The percentage of patients with final BCVA better than 1.0 was also significantly higher in patients without CRS vs patients with CRS at presentation (61.0% vs 7.1%, P<0.0001. There was no correlation between CRS and the time from symptoms. HBOT was found to be safe, and only 5.5% of patients had minor, reversible, adverse events.Conclusion: HBOT is an effective treatment for non-arteritic CRAO as long as CRS has not formed. The fundus findings, rather

  6. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  7. A patient with acute macular neuroretinopathy and central retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Hirooka K

    2013-07-01

    Full Text Available Kiriko Hirooka,1 Wataru Saito,1,2 Kousuke Noda,1,2 Susumu Ishida1,21Department of Ophthalmology, Hokkaido University Graduate School of Medicine, Sapporo, Japan; 2Department of Ocular Circulation and Metabolism, Hokkaido University Graduate School of Medicine, Sapporo, JapanPurpose: The precise mechanism causing acute macular neuroretinopathy (AMN is still unknown. A recent report suggested that choroidal circulation impairment correlates with its pathogenesis. We report a rare case with simultaneous onset of AMN and central retinal vein occlusion (CRVO, which is a retinal circulation disorder.Methods: Case report.Results: A 44-year-old woman complained of central visual loss of the left eye for the previous 2 weeks. The patient’s visual acuity was 0.5 in the left eye (OS. Fundoscopic examination revealed a wedge-shaped, dark reddish-brown lesion at the macula, and CRVO-like retinal hemorrhages OS. Fluorescein angiography revealed retinal vasculitis and hypofluorescence corresponding to the macular lesion. The patient’s scanning laser ophthalmoscopy infrared imaging result led to a diagnosis of AMN. Two weeks after corticosteroid pulse therapy, her visual acuity improved to 1.2 OS, with improvement of macular findings and Humphrey perimetry. When the dose of oral corticosteroid was decreased, the AMN lesion worsened, with recurrence of retinal hemorrhages. Visual functions improved again after an increased dose of corticosteroid.Conclusion: These results suggest that circulatory disorders almost simultaneously occurred in choroidal and retinal vessels, resulting in the onset of both AMN and CRVO.Keywords: choroidal circulation, optical coherence tomography, retinal circulation, systemic corticosteroid therapy

  8. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan [Wonkwang University Hospital, Iksan (Korea, Republic of)

    2008-02-15

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT.

  9. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan

    2008-01-01

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT

  10. A systematic review of extravasation and local tissue injury from administration of vasopressors through peripheral intravenous catheters and central venous catheters.

    Science.gov (United States)

    Loubani, Osama M; Green, Robert S

    2015-06-01

    The aim of this study was to collect and describe all published reports of local tissue injury or extravasation from vasopressor administration via either peripheral intravenous (IV) or central venous catheter. A systematic search of Medline, Embase, and Cochrane databases was performed from inception through January 2014 for reports of adults who received vasopressor intravenously via peripheral IV or central venous catheter for a therapeutic purpose. We included primary studies or case reports of vasopressor administration that resulted in local tissue injury or extravasation of vasopressor solution. Eighty-five articles with 270 patients met all inclusion criteria. A total of 325 separate local tissue injury and extravasation events were identified, with 318 events resulting from peripheral vasopressor administration and 7 events resulting from central administration. There were 204 local tissue injury events from peripheral administration of vasopressors, with an average duration of infusion of 55.9 hours (±68.1), median time of 24 hours, and range of 0.08 to 528 hours. In most of these events (174/204, 85.3%), the infusion site was located distal to the antecubital or popliteal fossae. Published data on tissue injury or extravasation from vasopressor administration via peripheral IVs are derived mainly from case reports. Further study is warranted to clarify the safety of vasopressor administration via peripheral IVs. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Peripheral venous distension elicits a blood pressure raising reflex in young and middle-aged adults.

    Science.gov (United States)

    Matthews, Evan L; Brian, Michael S; Coyle, Dana E; Edwards, David G; Stocker, Sean D; Wenner, Megan M; Farquhar, William B

    2016-06-01

    Distension of peripheral veins in humans elicits a pressor and sympathoexcitatory response that is mediated through group III/IV skeletal muscle afferents. There is some evidence that autonomic reflexes mediated by these sensory fibers are blunted with increasing age, yet to date the venous distension reflex has only been studied in young adults. Therefore, we tested the hypothesis that the venous distension reflex would be attenuated in middle-aged compared with young adults. Nineteen young (14 men/5 women, 25 ± 1 yr) and 13 middle-aged (9 men/4 women, 50 ± 2 yr) healthy normotensive participants underwent venous distension via saline infusion through a retrograde intravenous catheter in an antecubital vein during limb occlusion. Beat-by-beat blood pressure, muscle sympathetic nerve activity (MSNA), and model flow-derived cardiac output (Q), and total peripheral resistance (TPR) were recorded throughout the trial. Mean arterial pressure (MAP) increased during the venous distension in both young (baseline 83 ± 2, peak 94 ± 3 mmHg; P blood pressure, MSNA, and TPR were similar between young and middle-aged adults. Additionally, no correlation was found between age and the response to venous distension (all P > 0.05). These findings suggest that peripheral venous distension elicits a pressor and sympathetic response in middle-aged adults similar to the response observed in young adults. Copyright © 2016 the American Physiological Society.

  12. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    Science.gov (United States)

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  13. One-step reconstruction of the right inferior hepatic veins using auto-venous grafts in living-donor liver transplantation.

    Science.gov (United States)

    Ikegami, Toru; Shirabe, Ken; Yoshiya, Shohei; Soejima, Yuji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Toshima, Takeo; Motomura, Takashi; Maehara, Yoshihiko

    2013-07-01

    Reconstruction of the right inferior hepatic vein (RIHV) presents a major technical challenge in living donor liver transplantation (LDLT) using right lobe grafts. We studied 47 right lobe LDLT grafts with RIHV revascularization, comparing one-step reconstruction, performed post-May 2007 (n = 16), with direct anastomosis, performed pre-May 2007 (n = 31). In the one-step reconstruction technique, the internal jugular vein (n = 6), explanted portal vein (n = 5), inferior vena cava (n = 3), and shunt vessels (n = 2) were used as venous patch grafts for unifying the right hepatic vein, RIHVs, and middle hepatic vein tributaries. By 6 months after LDLT, there was no case of occlusion of the reconstructed RIHVs in the one-step reconstruction group, but a cumulative occlusion rate of 18.2 % in the direct anastomosis group. One-step reconstruction required a longer cold ischemic time (182 ± 40 vs. 115 ± 63, p one-step reconstruction and 83.9 % with direct anastomosis, respectively. One-step reconstruction of the RIHVs using auto-venous grafts is an easy and feasible technique promoting successful right lobe LDLT.

  14. Three-dimensional contrast-enhanced magnetic resonance angiography (3-D CE-MRA) in the evaluation of hemodialysis access complications, and the condition of central veins in patients who are candidates for hemodialysis access.

    Science.gov (United States)

    Paksoy, Yahya; Gormus, Niyazi; Tercan, Mehmet Akif

    2004-01-01

    Arteriovenous (AV) fistulas are crucial in patients requiring long-term hemodialysis (HD). Dysfunctions of these fistulas are the most common causes of recurrent hospitalizations. This study aimed to evaluate the feasibility, safety and usefulness of contrast-enhanced magnetic resonance angiography (CE-MRA) in the evaluation of HD fistulas complications, and the condition of the central veins before HD access. This study comprised 30 consecutive patients (15 females, 15 males; age range 25-66 yrs, mean +/- SD 51.2 +/- 9.9 yrs). Of 30 patients, 26 had native AV fistulas and the remaining four patients, who had a history of previous subclavian vein catheterization, were candidates for HD fistulas. Nine patients had a radiocephalic fistula, 15 had a brachiobasilic fistula, one had a saphenous vein graft, and one had brachiobasilic vein transposition. To observe the fistula complications in these cases, three-dimensional (3-D) CE-MRA using gadolinium was performed. The results were considered normal in three patients (10%), who were candidates for AV fistula construction; one patient had central vein occlusion due to previous catheterization. Thirteen patients (43.3%) had venous stenosis or occlusion; three of them (10%) had low CE arteries distal to fistula region, leading to ischemic complications, and six (20%) had stenosis at the fistula region. Seven patients (23.3%) had venous pseudoaneurysms, whereas two of them had both pseudoaneurysms and fistula region stenosis, and one had both venous stenosis and pseudoaneurysm. There were no adverse or allergic-like reactions or heat and taste sensations observed in our series. 3-D CE-MRA is a useful, safe and a practical imaging modality in complicated fistula diagnosis with fewer complications and side-effects in comparison to fistulography.

  15. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P; Lackner, K [Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik; Goetz, R [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  16. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    Science.gov (United States)

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to fashion (proximal: r 2  = 0.85, p trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone I P-REBOA during the staged partial aortic occlusion. These parameters should be considered potential parameters to define the degree of P-REBOA during animal research and clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Maximal venous outflow velocity: an index for iliac vein obstruction.

    Science.gov (United States)

    Jones, T Matthew; Cassada, David C; Heidel, R Eric; Grandas, Oscar G; Stevens, Scott L; Freeman, Michael B; Edmondson, James D; Goldman, Mitchell H

    2012-11-01

    Leg swelling is a common cause for vascular surgical evaluation, and iliocaval obstruction due to May-Thurner syndrome (MTS) can be difficult to diagnose. Physical examination and planar radiographic imaging give anatomic information but may miss the fundamental pathophysiology of MTS. Similarly, duplex ultrasonographic examination of the legs gives little information about central impedance of venous return above the inguinal ligament. We have modified the technique of duplex ultrasonography to evaluate the flow characteristics of the leg after tourniquet-induced venous engorgement, with the objective of revealing iliocaval obstruction characteristic of MTS. Twelve patients with signs and symptoms of MTS were compared with healthy control subjects for duplex-derived maximal venous outflow velocity (MVOV) after tourniquet-induced venous engorgement of the leg. The data for healthy control subjects were obtained from a previous study of asymptomatic volunteers using the same MVOV maneuvers. The tourniquet-induced venous engorgement mimics that caused during vigorous exercise. A right-to-left ratio of MVOV was generated for patient comparisons. Patients with clinical evidence of MTS had a mean right-to-left MVOV ratio of 2.0, asymptomatic control subjects had a mean ratio of 1.3, and MTS patients who had undergone endovascular treatment had a poststent mean ratio of 1.2 (P = 0.011). Interestingly, computed tomography and magnetic resonance imaging results, when available, were interpreted as positive in only 53% of the patients with MTS according to both our MVOV criteria and confirmatory venography. After intervention, the right-to-left MVOV ratio in the MTS patients was found to be reduced similar to asymptomatic control subjects, indicating a relief of central venous obstruction by stenting the compressive MTS anatomy. Duplex-derived MVOV measurements are helpful for detection of iliocaval venous obstruction, such as MTS. Right-to-left MVOV ratios and

  18. Total anomalous systemic venous drainage in left heterotaxy syndrome.

    Science.gov (United States)

    Khandenahally, Ravindranath S; Deora, Surender; Math, Ravi S

    2013-04-01

    Total anomalous systemic venous drainage is an extremely rare congenital heart defect. In this study we describe an 11-year-old girl who presented with a history of fatigue and central cyanosis that she had had since early childhood with unremarkable precordial examination results. Investigations revealed left heterotaxy with all systemic venous drainage to the left-sided atrium with non-compaction of the left ventricle.

  19. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    Science.gov (United States)

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  20. Central Venous Catheter (CVC related infections: a local retrospective study

    Directory of Open Access Journals (Sweden)

    Manuela Fresu

    2008-06-01

    Full Text Available Background. Central venous catheter (CVC related infection is associated with significant increases in morbidity, mortality, and health care cost.This local surveillance study was carry out to monitor the frequency of occurrence of CVC-related blood stream infections. Materials and methods. During the period January – December 2005, 226 CVC specimens were analyzed (quantitative method and microrganism identification from positive samples was performed by Vitek II. In 53 patients it was possible to compare quantitative results with those obtained from blood cultures. Results. Positive CVC samples were 125 (55% and 130 microrganisms were isolated: 109 Gram-positives (84%, 4 Gram-negatives (3%, and 17 mycetes (13%. Among pathogens collected simultaneously from CVC and blood samples, the most frequently isolated were Staphylococcus spp. (30% coagulase-negative staphylococci and 20%. S. aureus and Candida spp. (45%. In the group of patients that presented positive CVC and negative blood samples the most frequently recovered microrganisms were staphylococci. Many isolates (33% were polymicrobial. Conclusions. Catheter-related infections occurred in those patients who presented the same pathogen in both CVC and blood cultures. These infections were principally caused by staphylococci and Candida spp. On the contrary, a possible CVC contamination could be suspected when positive CVC and negative blood cultures were found.

  1. Transcatheter therapy in partially abnormal pulmonary venous return with additional drainage to the left atrium.

    Science.gov (United States)

    Luciano, Debora; Laux, Daniela; Boudjemline, Younes; Hascoët, Sébastien; Lusson, Jean-René; Sorensen, Clio; Ovaert, Caroline; Kreitmann, Bernard; Van Praagh, Richard; Fraisse, Alain

    2013-12-10

    A persistent anastomosis between the pulmonary veins that connect with the left atrium and the systemic vein that drains into the right atrium has occasionally been reported. We report characteristics and transcatheter therapy in partially abnormal pulmonary venous return with additional drainage to the left atrium. We retrospectively studied such patients in 5 institutions. Ten patients (6 girls) presented at a median age of 8 (0.1 to 54) years with 2 anatomic types: 8 vertical vein types with drainage of the left upper lobe to the innominate vein via a large vertical vein (left superior cardinal vein) and to the left atrium via the left upper pulmonary vein; and 2 scimitar vein (SV) types with drainage of the right middle and lower pulmonary veins into the inferior vena cava and to the left atrium via an anomalous connecting vein. Associated malformations were aortic coarctation (n=2) and secundum atrial septal defects (n=3). Two patients of the vertical vein type were operated. Transcatheter occlusion of the abnormal pulmonary venous return was performed in 7 cases, associated with occlusion of systemic arterial supply (n=2), secundum atrial septal closure (n=2), left upper pulmonary vein stenosis stenting (n=1), and coarctation stenting (n=1). Including previously published cases, 18 patients (13 vertical veins and 5 scimitar veins) underwent transcatheter repair. Patients over 40 years of age tend to be symptomatic at presentation (p=0.056). In partially abnormal pulmonary venous return with dual drainage, transcatheter therapy can be offered in the majority of patients. © 2013.

  2. Histological study of rat masseter muscle following experimental occlusal alteration.

    Science.gov (United States)

    Nishide, N; Baba, S; Hori, N; Nishikawa, H

    2001-03-01

    It has been suggested that occlusal interference results in masticatory muscle dysfunction. In our previous study, occlusal interference reduced the rat masseter energy level during masticatory movements. The purpose of this study was to investigate the histological alterations of rat masseter muscles following experimental occlusal alteration with unilateral bite-raising. A total of eight male adult Wistar rats were equally divided into control and experimental groups. The experimental rats wore bite-raising splints on the unilateral upper molar. However, 4 weeks after the operation, the anterior deep masseter muscles were removed and then stained for succinic acid dehydrogenase (SDH), haematoxylin eosin (HE) and myofibrillar ATPase. Most of the muscle fibres in experimental rats remained intact, although partial histological changes were observed, such as extended connective tissue, appearance of inflammatory cells in the muscle fibres and existence of muscle fibres with central nuclei and central cores. Moreover, the fibre area-fibre frequency histograms of experimental muscle indicated a broad pattern than that of controls. These results indicated that occlusal interference caused histological changes in masseter muscles and that this may be related to the fact that the masseter energy level was reduced during masticatory movements in unilateral bite-raised rats.

  3. Occlusal stability.

    Science.gov (United States)

    Wiens, Jonathan P; Priebe, Jennifer W

    2014-01-01

    Occlusion is the foundation for clinical success in fixed, removable, and implant prosthodontic treatment. Understanding those principles is critical when restoring a patient's occlusion. Many philosophies, devices, and theories of occlusion have evolved based on anecdotal clinical observations and applied geometric perceptions. The literature has reported these classic and contemporary occlusal concepts. As evidence-based dentistry emerged, it championed scrutiny of previously held beliefs, resulting in the abandonment of many pragmatic, yet beneficial occlusal procedures. The impetus toward scientific discovery, whereby factual information might be universally applied in dental education and clinical practice, has renewed interest in occlusal studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery.

  5. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    International Nuclear Information System (INIS)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook

    2017-01-01

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery

  6. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Rhodococcus equi venous catheter infection: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Nahleh Zeina

    2011-08-01

    Full Text Available Abstract Introduction Rhodococcus equi is an animal pathogen that was initially isolated from horses and is being increasingly reported as a cause of infection in humans with impaired cellular immunity. However, this pathogen is underestimated as a challenging antagonist and is frequently considered to be a mere contaminant despite the potential for life-threatening infections. Most case reports have occurred in immunocompromised patients who have received organ transplants (for example kidney, heart, bone marrow or those with human immunodeficiency virus infection. Infections often manifest as pulmonary involvement or soft tissue abscesses. Bacteremia related to R. equi infections of tunneled central venous catheters has rarely been described. Case presentation We report the case of a 63-year-old non-transplant recipient, non-HIV infected Caucasian woman with endometrial carcinoma who developed recurrent bloodstream infections and septic shock due to R. equi and ultimately required the removal of her port catheter, a subcutaneous implantable central venous catheter. We also review the medical literature related to human infections with R. equi. Conclusion R. equi should be considered a serious pathogen, not a contaminant, particularly in an immunocompromised patient who presents with a central venous catheter-related bloodstream infection. Counseling patients with central venous catheters who participate in activities involving exposure to domesticated animals is recommended.

  8. [Venous thrombosis of atypical location in patients with cancer].

    Science.gov (United States)

    Campos Balea, Begoña; Sáenz de Miera Rodríguez, Andrea; Antolín Novoa, Silvia; Quindós Varela, María; Barón Duarte, Francisco; López López, Rafael

    2015-01-01

    Venous thromboembolism (VTE) is a complication that frequently occurs in patients with neoplastic diseases. Several models have therefore been developed to identify patient subgroups diagnosed with cancer who are at increased risk of developing VTE. The most common forms of thromboembolic episodes are deep vein thrombosis in the lower limbs and pulmonary thromboembolism. However, venous thrombosis is also diagnosed in atypical locations. There are few revisions of unusual cases of venous thrombosis. In most cases, VTE occurs in the upper limbs and in the presence of central venous catheters, pacemakers and defibrillators. We present the case of a patient diagnosed with breast cancer and treated with surgery, chemotherapy and radiation therapy who developed a thrombosis in the upper limbs (brachial and axillary). Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  9. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  10. [Subcutaneous implantation type central venous port management in patients with malignant tumors effect of different antiseptic agents on central venous port-related infection].

    Science.gov (United States)

    Sato, Junya; Kumagai, Masumi; Kato, Kenichi; Akahane, Akio; Suzuki, Michiko; Kashiwaba, Masahiro; Sone, Miyuki; Kudo, Kenzo

    2014-08-01

    Subcutaneous implantation type central venous ports(CV ports)are used in chemotherapy. Here, we prospectively examined the frequency of CV port-related infections when the disinfectant was changed from 10% povidone iodine to 1% chlorhexidine ethanol or 70% ethanol. The subjects were patients with malignant tumors, who had newly been implanted with CV ports. We examined CV port-related infections at 1 week after CV port implantation and every 2 weeks thereafter, following sterilization upon insertion of a Huber needle to the CV port. CV port evulsion due to CV port-related infection was noted in 3 patients(4.8%)in whom 15%chlorhexidine ethanol was used(n=62)and in 2 patients(3.3%)in whom 70% ethanol was used(n=60). Infection rates per 1,000 days of CV port use were 1.48% and 1.01%, respectively. Thus, the outcomes of sterilization using 1% chlorhexidine ethanol and 70% ethanol did not differ significantly from those on using 10% povidone iodine for sterilization, based on preliminary results at our institution(3 of 59 patients[5.1%]had port evulsion due to CV port-related infection and the infection rate per 1,000 days of CV port use was 1.47%, Akahane et al, 2012). Chlorhexidine ethanol and ethanol are very convenient to use because they dry quickly and do not need discoloration. Accordingly, chlorhexidine ethanol and ethanol might be useful in CV port management.

  11. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?

    International Nuclear Information System (INIS)

    Wattjes, M.P.; Doepp, F.; Bendszus, M.; Fiehler, J.

    2011-01-01

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  12. Experimental occlusal interference induces long-term masticatory muscle hyperalgesia in rats.

    Science.gov (United States)

    Cao, Ye; Xie, Qiu-Fei; Li, Kai; Light, Alan R; Fu, Kai-Yuan

    2009-08-01

    Temporomandibular joint or related masticatory muscle pain represents the most common chronic orofacial pain condition. Patients frequently report this kind of pain after dental alterations in occlusion. However, lack of understanding of the mechanisms of occlusion-related temporomandibular joint and muscle pain prevents treating this problem successfully. To explore the relationship between improper occlusion (occlusal interference) and masticatory muscle pain, we created an occlusal interference animal model by directly bonding a crown to a maxillary molar to raise the masticating surface of the tooth in rats. We raised the occlusal surface to three different heights (0.2, 0.4, and 0.6mm), and for one month we quantitatively measured mechanical nociceptive thresholds of the temporal and masseter muscles on both sides. Results showed a stimulus-response relationship between the height of occlusal interference and muscle hyperalgesia. Removal of the crown 6 days after occlusal interference showed that the removal at this time could not terminate the 1 month duration of mechanical hyperalgesia in the masticatory muscles. Lastly, we systemically administered NMDA antagonist MK801 (0.2, 0.1, and 0.05 mg/kg) to the treated rats and found that MK801 dose dependently attenuated the occlusal interference-induced hyperalgesia. These findings suggest that occlusal interference is directly related to masticatory muscle pain, and that central sensitization mechanisms are involved in the maintenance of the occlusal interference-induced mechanical hyperalgesia.

  13. Self care of patients with chronic venous ulcers in the home environment.

    Directory of Open Access Journals (Sweden)

    Thiago Gonçalves do Nascimento Piropo

    2012-01-01

    Full Text Available The venous ulcer is a skin lesion that affects the lower third of the legs. Is associated with chronic venous insufficiency, is the leading cause of ulcers of the lower limbs. Can interfere with the quality of life of patients, because it generates negative repercussions on social and economic sphere. The aim of this study was to identify self-care in the home environment of patients with venous ulcers, to assess the occurrence of alternative therapy use and verifythe involvement of domestic trauma. Methodologically, this study takes a quantitative and qualitative analytical cross-sectional held at the Clinical School of Physiotherapy, State University of Southwest Bahia / UESB / Jequié-BA, from January 2007 to September 2008. Data were collected through a questionnaire and semi-structured interviews. The results showed that 100% of the participants played self care of their injuries, including with respect to occlusion and bandages when needed. However, 6.25% said they had not received adequate information to perform self-care. Concluded that it is necessary to interact and produce a mechanism between education and health assistance for the development of the practice of self-care in family life at home.

  14. Computer Identification of Symptomatic Deep Venous Thrombosis Associated with Peripherally Inserted Central Catheters

    Science.gov (United States)

    Evans, R. Scott; Linford, Lorraine H.; Sharp, Jamie H.; White, Gayle; Lloyd, James F.; Weaver, Lindell K.

    2007-01-01

    Peripherally inserted central catheters (PICCs) are considered a safe method to provide long-term antibiotic therapy, chemotherapy and nutrition support. Deep venous thrombosis (DVT) is a complication that requires early PICC removal, may extend hospitalization and can result in pulmonary embolism. PICC insertion teams strive to understand risk factors and develop methods to prevent DVTs. However, they can only manage what they can measure. At LDS Hospital, identification of PICC associated DVTs was dependent on verbal notification or manual surveillance of more than a thousand free-text vascular reports. Accurate DVT rates were not known which hindered prevention. We describe the development of a computer application (PICC-DVT monitor) to identify PICC associated DVTs each day. A one-year evaluation of the monitor by the PICC team and a review of 445 random vascular reports found a positive predictive value of 98%, sensitivity of 94%, specificity of 100% and a PICC team associated DVT rate of 2.8%. PMID:18693831

  15. Cost of installing and turning off hemodialysis on patients with central venous catheters

    Directory of Open Access Journals (Sweden)

    Gillene Santos Ferreira

    2014-12-01

    Full Text Available The objective was to identify the average total cost (ATC for installing and turning off hemodialysis on patients with central venous catheters. This quantitative, exploratory, and descriptive research, in the mode of a single-case study, was conducted in a public university hospital. The non-probabilistic sample corresponded to the observation of 100 installations and 100 terminations of hemodialysis on 42 patients during 23 days of collection. The ATC was calculated by multiplying the time spent by nurses by the unit cost of direct labor, and adding the cost of materials, solutions, and medications. The Brazilian currency (R$ was used for the calculations. The ATC for installation was R$ 80.10 and for shutting off was R$ 13.04, totaling R$ 93.14 per hemodialysis session. The results obtained will facilitate a better planning of the allocation of human, material, and financial resources enabling the increase of managerial strategies aimed at economic efficiency. doi: 10.5216/ree.v16i4.23044.

  16. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  17. Nitroglycerine and patient position effect on central, hepatic and portal venous pressures during liver surgery.

    Science.gov (United States)

    Sand, L; Lundin, S; Rizell, M; Wiklund, J; Stenqvist, O; Houltz, E

    2014-09-01

    To reduce blood loss during liver surgery, a low central venous pressure (CVP) is recommended. Nitroglycerine (NG) with its rapid onset and offset can be used to reduce CVP. In this study, the effect of NG on portal and hepatic venous pressures (PVP and HVP) in different body positions was assessed. Thirteen patients undergoing liver resection were studied. Cardiac output (CO), mean arterial pressure (MAP) and CVP were measured. PVP and HVP were measured using tip manometer catheters at baseline (BL) in horizontal position; during NG infusion, targeting a MAP of 60 mmHg, with NG infusion and the patient placed in 10 head-down position. NG infusion reduced HVP from 9.7 ± 2.4 to 7.2 ± 2.4, PVP from 12.3 ± 2.2 to 9.7 ± 3.0 and CVP from 9.8 ± 1.9 to 7.2 ± 2.1 mmHg at BL. Head-down tilt during ongoing NG resulted in increases in HVP to 8.2 ± 2.1, PVP to 10.7 ± 3 and CVP to 11 ± 1.9 mmHg. CO at BL was 6.3 ± 1.1, which was reduced by NG to 5.8 ± 1.2. Head-down tilt together with NG infusion restored CO to 6.3 ± 1.0 l/min. NG infusion leads to parallel reductions in CVP, HVP and PVP at horizontal body position. Thus, CVP can be used to guide NG dosage and fluid administration at horizontal position. NG infusion can be used to reduce HVP. Head-down tilt can be used during NG infusion to improve both blood pressure and CO without substantial increase in liver venous pressure. In head-down tilt, CVP dissociates from HVP and PVP. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  19. Retrospective analyses of optical coherence tomography in recurrent macular edema following intravitreal therapy in patients with retinal vein occlusion.

    Science.gov (United States)

    Holland, Stephen M; Dodwell, David G; Krimmel, Darrel A; de Fiebre, Christopher M

    2015-09-04

    Optical coherence tomography has focused mainly on central subfield thickness to quantify macular edema in central and branch retinal vein occlusion. We examined macular fields other than the central subfield to determine if they are possibly independent indicators of recurrent macular edema. Single center, retrospective, consecutive case study of patients with recurrent macular edema secondary to either central or branch retinal vein occlusion. Thickness estimates of serial domain optical coherence tomography macular fields were obtained at the time of recurrent macular edema and analyzed retrospectively. Changes were expressed as a percentage of previous baseline levels. Change in thickness at each retreatment episode as well as average changes in thickness were calculated for each macular field for each eye. Data were analyzed via analysis of variance and Fisher's post hoc analyses. The macular field which most frequently had the largest percent increase at the time of recurrence was also assessed using averages for each subject as well as for each retreatment episode. Individual episodes of recurrent macular edema were also examined to ascertain the frequency in which there was minimal foveal edema (<15 μm increase), but non-foveal edema was considered severe enough to warrant retreatment. 429 episodes of recurrent macular edema in 80 eyes were examined. In addition to the central subfield, the average mean change in thickness of the most affected quadrant (central vein occlusion) or hemisphere (branch vein occlusion) of the extrafoveal 3 mm band had the largest mean changes and also most frequently had the largest increases at the time of recurrent macular edema. In approximately 20 % of both central and branch occlusions, recurrent macular edema was detected in non-central macular fields in the absence of significant edema in the central subfield. Analyses of non-central macular fields as well as the central subfield may be useful in the early detection

  20. Balloon occlusion of the internal carotid artery in 40 cases of giant intracavernous aneurysm: Technical aspects, cerebral monitoring, and results

    International Nuclear Information System (INIS)

    Vazquez Anon, V.; Aymard, A.; Gobin, Y.P.; Casasco, A.; Rueffenacht, D.; Khayata, M.H.; Merland, J.J.; Abizanda, E.; Redondo, A.

    1992-01-01

    We have studied the results of carotid occlusion in the treatment of giant intracavernous carotid artery (ICA) aneurysms in 40 patients. Clinical, angiographic, Doppler and cerebral blood flow (CBF) criteria for tolerance of occlusion are discussed. The patients had headaches (47.5%), cranial nerve compression (87.5%), decreased visual acuity (20%), ruptured aneurysm (15%) and 5% were asymptomatic. Balloon occlusion tests were performed under light sedation anaesthesia; a successful test required perfect clinical tolerance and adequate angiographic collateral circulation in arterial, parenchymatous, and venous phases. Additional criteria included xenon 133 CBF measurements, and transcranial Doppler sonography of the middle cerebral artery. According to these criteria, 5 patients did not tolerate test occlusion and required an extra-intracranial (EC-IC) bypass. Mean follow-up was 4.7 years. All patients were radiologically cured of their aneurysm, and in 35 the symptoms resolved, although 3 had persistent ocular motor nerve palsies, and in 4 visual defects were unchanged. Complications were 1 permament and 3 transient neurological deficits. Balloon occlusion of the ICA is an effective, reliable form of treatment for intracavernous giant aneurysm and should replace surgical ligation of the cervical carotid artery. With CBF or Doppler monitoring, the risk of neurological deficit is diminished. EC-IC bypass prior to ICA occlusion is indicated if test occlusion is not tolerated. (orig.)

  1. Gestational related changes in the deep venous system of the lower limb on light reflection rheography in pregnancy and the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Calderwood, C.J. [St John' s Hospital, Livingston and Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom)], E-mail: catherine.calderwood@luht.scot.nhs.uk; Jamieson, R. [Princess Royal Maternity Unit, Glasgow Royal Infirmary, Glasgow (United Kingdom); Greer, I.A. [Hull York Medical School, University of York, York (United Kingdom)

    2007-12-15

    Objective: To assess whether light reflection rheography testing is affected by the changes that occur in the deep venous system of the lower limb in pregnancy and the puerperium. Methods: Twenty five women with a singleton pregnancy were recruited to undergo duplex Doppler ultrasound examinations of the common femoral vein to measure the vessel diameter and the blood flow velocity. Light reflection rheography testing was subsequently performed and the rate of venous emptying in the lower limb calculated. Serial measurements using both techniques were made at 15, 28, 36 weeks, and term gestation and at 2 days and 6 weeks postpartum. Results: Duplex Doppler ultrasound confirmed that there is progressive dilatation of the deep venous system in pregnancy, which reaches a maximum at term and reverses after delivery. There is an accompanying reduction in blood flow velocity, which reaches a nadir at term and increases after delivery. The rate of venous emptying as measured by light reflection rheography decreases with increasing gestation, but did not fall to a level consistent with venous occlusion by a deep venous thrombosis. Conclusions: Light reflection rheography has been shown to provide reliable results in pregnancy and the puerperium. Therefore, it is a potential tool for screening for deep venous thrombosis in this population.

  2. Gestational related changes in the deep venous system of the lower limb on light reflection rheography in pregnancy and the puerperium

    International Nuclear Information System (INIS)

    Calderwood, C.J.; Jamieson, R.; Greer, I.A.

    2007-01-01

    Objective: To assess whether light reflection rheography testing is affected by the changes that occur in the deep venous system of the lower limb in pregnancy and the puerperium. Methods: Twenty five women with a singleton pregnancy were recruited to undergo duplex Doppler ultrasound examinations of the common femoral vein to measure the vessel diameter and the blood flow velocity. Light reflection rheography testing was subsequently performed and the rate of venous emptying in the lower limb calculated. Serial measurements using both techniques were made at 15, 28, 36 weeks, and term gestation and at 2 days and 6 weeks postpartum. Results: Duplex Doppler ultrasound confirmed that there is progressive dilatation of the deep venous system in pregnancy, which reaches a maximum at term and reverses after delivery. There is an accompanying reduction in blood flow velocity, which reaches a nadir at term and increases after delivery. The rate of venous emptying as measured by light reflection rheography decreases with increasing gestation, but did not fall to a level consistent with venous occlusion by a deep venous thrombosis. Conclusions: Light reflection rheography has been shown to provide reliable results in pregnancy and the puerperium. Therefore, it is a potential tool for screening for deep venous thrombosis in this population

  3. Intramuscular ketamine to facilitate pediatric central vascular access.

    Science.gov (United States)

    Denmark, T Kent; Hargrove, Jenny R; Brown, Lance

    2004-07-01

    Obtaining prompt vascular access in young children presenting to the emergency department (ED) is frequently both necessary and technically challenging. The objective of our study was to describe our experience using intramuscular (IM) ketamine to facilitate the placement of central venous catheters in children presenting to our ED needing vascular access in a timely fashion. We performed a retrospective medical record review of all pediatric patients central venous catheter facilitated by the use of IM ketamine. Eleven children met our inclusion criteria. Most of the children were young and medically complicated. The children ranged in age from 6 months to 8 years. The only complication identified was vomiting experienced by an 8-year-old boy. Emergency physicians successfully obtained central venous access in all subjects in the case series. The use of IM ketamine to facilitate the placement of central venous catheters in children who do not have peripheral venous access appears to be helpful. Emergency physicians may find it useful to be familiar with this use of IM ketamine.

  4. Carotid cavernous fistula with central retinal artery occlusion and Terson syndrome after mid-facial trauma

    Directory of Open Access Journals (Sweden)

    Karna, Satya

    2017-05-01

    Full Text Available Objectives: To report a rare occurrence combination of central retinal artery occlusion (CRAO and Terson syndrome in a Barrow’s type A carotid cavernous fistula (CCF patient.Methods: Observational case report.Results: A twenty-year-old male patient with a history of road traffic accident presented with periorbital swelling and redness in the left eye. Examination revealed a CRAO with intraretinal and preretinal hemorrhages. On imaging, type A CCF and subarachnoid hemorrhage were detected. He underwent embolization of the fistula for cosmetic blemish. The possible mechanisms and clinical implications are discussed. Conclusion: Patients with a head injury can have serious ocular damage. Posterior segment manifestations of CCFs are varied and at times can occur in various rare combinations, making it challenging. Early recognition of these rare manifestations and a multi-disciplinary approach are needed in patients with head trauma.

  5. Micro Vascular Plug (MVP)-assisted vessel occlusion in neurovascular pathologies: technical results and initial clinical experience.

    Science.gov (United States)

    Beaty, Narlin B; Jindal, Gaurav; Gandhi, Dheeraj

    2015-10-01

    Deconstructive approaches may be necessary to treat a variety of neurovascular pathologies. Recently, a new device has become available for endovascular arterial occlusion that may have unique applications in neurovascular disease. The Micro Vascular Plug (MVP, Reverse Medical, Irvine, California, USA) has been designed for vessel occlusion through targeted embolization. To report the results from our initial experience with eight consecutive patients in whom the MVP was used to achieve endovascular occlusion of an artery in the head and neck. Eight consecutive patients treated over a nine-month period were included. The patients' radiographic and electronic medical records were retrospectively reviewed. Specifically demographic information, clinical indication, site of arterial occlusion, size of MVP, time to vessel occlusion, clinical complications, use of other secondary embolic agents, and clinical outcome were recorded. Follow-up information when available is presented. The MVP was used in eight patients for the treatment of neurovascular disease. Indications for treatment included post-traumatic head/neck bleeding (n=3), carotid-cavernous fistula (1), vertebral-vertebral fistula (1), giant fusiform vertebral aneurysm (1), stump-emboli after carotid dissection (1), and iatrogenic vertebral artery penetrating injury (1). One device was used in five patients, two in two patients, and one patient with extensive vertebral-vertebral venous fistula required three plugs to effectively trap the fistula from proximal and distal aspects. Vessel occlusion was obtained in MVP in neurovascular disease. Use of this device may be associated with shorter procedural times and cost savings in comparison with the use of microcoils for vessel occlusion. Our experience shows that MVP can have unique applications in neurovascular pathologies and it complements other occlusive devices. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted

  6. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong [School of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    2000-09-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  7. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong

    2000-01-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  8. Tricuspid valve endocarditis following central venous cannulation: The increasing problem of catheter related infection

    Directory of Open Access Journals (Sweden)

    Suresh Babu Kale

    2013-01-01

    Full Text Available A central venous catheter (CVC is inserted for measurement of haemodynamic variables, delivery of nutritional supplements and drugs and access for haemodialysis and haemofiltration. Catheterization and maintenance are common practices and there is more to the technique than routine placement as evident when a procedure-related complication occurs. More than 15% of the patients who receive CVC placement have some complications and infectious endocarditis involving the tricuspid valve is a rare and serious complication with high morbidity and mortality. Overenthusiastic and deep insertion of the guide wire and forceful injection through the CVC may lead to injury of the tricuspid valve and predispose to bacterial deposition and endocarditis. We report a case of tricuspid valve endocarditis, probably secondary to injury of the anterior tricuspid leaflet by the guide wire or the CVC that required open heart surgery with vegetectomy and repair of the tricuspid valve.

  9. Central retinal artery occlusion in a patient with ANCA-negative Churg-Strauss syndrome

    Science.gov (United States)

    Kumano, Yuji; Yoshida, Noriko; Fukuyama, Satoru; Miyazaki, Masanori; Enaida, Hiroshi; Matsui, Takaaki

    2012-01-01

    Ocular involvement in Churg-Strauss syndrome is infrequent. We describe the case of a 54-year-old woman with eosinophilia and involvement of the respiratory tract, skin, and peripheral nervous system, fulfilling the American College of Rheumatology criteria for Churg-Strauss syndrome. The patient presented with acute, painless vision loss in her right eye. Central retinal artery occlusion (CRAO) without accompanying retinal vasculitis was diagnosed by angiographic findings and funduscopic findings of retinal whitening with a cherry-red spot. Although her antineutrophil cytoplasmic antibody (ANCA) status was negative, CRAO was thought to be an ocular manifestation of Churg-Strauss syndrome, and appropriate treatment was planned. She was treated with high-dose corticosteroids and anticoagulant therapy. Her macular edema improved, but visual recovery was poor. Specific therapy to alter inflammation, blood coagulation, and rheology reportedly plays an important role in ANCA-positive patients with Churg-Strauss syndrome who develop CRAO. Regardless of ANCA status, high-dose corticosteroids should be considered for CRAO in patients with Churg-Strauss syndrome, as discussed in this case. PMID:22927731

  10. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study.

    Science.gov (United States)

    Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe

    2015-01-01

    The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.

  11. The collateral venous system in late pregnancy: A systematic review of the literature.

    Science.gov (United States)

    Humphries, Aimee; Stone, Peter; Mirjalili, S Ali

    2017-11-01

    Recent literature has reported an association between maternal supine sleep position and stillbirth during late pregnancy. In this position the gravid uterus almost completely obstructs the inferior vena cava. A small number of women experience supine hypotension, thought to be due in part to inadequate collateral venous circulation. The aim of this paper is to review the literature describing the anatomy of the collateral venous system and in particular the azygos system, the abdominal portion of which has not been well studied. A systematic review was conducted using the electronic databases: Medline, Embase, Scopus, and Google Scholar. Relevant anatomical and radiological literature concerning the azygos system in particular was reviewed. The search was limited to adult human studies only. The collateral venous system can be divided into superficial, intermediate and deep systems. The azygos system in particular provides immediate collateral venous circulation in the event of acute inferior vena caval obstruction. The abdominal portion of this pathway, including the ascending lumbar vein, has not been well studied and there are certain variations that can render it ineffective. In conclusion, the collateral venous system provides an alternative route for blood to flow back to the systemic circulation when acute occlusion of the inferior vena cava occurs in the supine position during late pregnancy. However, certain anatomical variations can render this pathway ineffective, and this could have implications for the development of supine hypotension and stillbirth in late pregnancy. Clin. Anat. 30:1087-1095, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. CT imaging of hepatic veno-occlusive disease (an analysis 14 cases)

    International Nuclear Information System (INIS)

    Zhang Guohua; Kong Azhao; Fang Junwei; Chen Yuejing; Zheng Weiliang; Dong Danjun; Zhang Shizheng

    2006-01-01

    Objective: To probe imaging characteristics of the hepatic veno-occlusive disease (VOD) based on clinical features and abdomen CT findings. Methods: Fourteen patients including 6 male and 8 female aged from 41 to 73 years were enrolled in this study. They all had previous trauma history and notoginseng was given as herbal remedy. Dynamic enhanced CT and color Dopplor ultrasound examinations were routinely used. Two of them received venous angiography and four cases were pathologically proved as VOD after CT guided needle biopsy. Results: Hepatic swelling and ascites were found on plain CT scan. Diffuse patchy areas without enhancement indicative of poorly hepatic perfusion were found. Hepatic veins were compressed and became thin, and inferior vena cava was flat and narrow without distal dilation or collateral circulation. No obstruction of hepatic veins and inferior vena cava was found on ultrasound and venography. Conclusion: Dynamic enhanced CT is highly valuable for early assessing VOD and imaging features of venous hepatic congestion found on CT was strongly suggestive of VOD if there's previous history of treatment of gynura segetum. (authors)

  13. Central nervous system decompression sickness and venous gas emboli in hypobaric conditions.

    Science.gov (United States)

    Balldin, Ulf I; Pilmanis, Andrew A; Webb, James T

    2004-11-01

    Altitude decompression sickness (DCS) that involves the central nervous system (CNS) is a rare but potentially serious condition. Identification of early symptoms and signs of this condition might improve treatment. We studied data from 26 protocols carried out in our laboratory over the period 1983-2003; all were designed to provoke DCS in a substantial proportion of subjects. The data set included 2843 cases. We classified subject-exposures that resulted in DCS as: 1) neurological DCS of peripheral and/or central origin (NEURO); 2) a subset of those that involved only the CNS (CNS); and 3) all other cases, i.e., DCS cases that did not have a neurological component (OTHER). For each case, echo imaging data were used to document whether venous gas emboli (VGE) were present, and their level was classified as: 1) any level, i.e., Grade 1 or higher (VGE-1); and 2) high level, Grade 4 (VGE-4). There were 1108 cases of altitude DCS in the database; 218 were classified as NEURO and 49 of those as CNS. VGE-1 were recorded in 83.8% of OTHER compared with 58.7% of NEURO and 55.1% of CNS (both p Hyperbaric oxygen (HBO) was used to treat about half of the CNS cases, while all other cases were treated with 2 h breathing 100% oxygen at ground level. Since only about half of the rare cases of hypobaric CNS DCS cases were accompanied by any level of VGE, echo imaging for bubbles may have limited application for use as a predictor of such cases.

  14. Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?

    Science.gov (United States)

    Martyak, Michael; Kabir, Ishraq; Britt, Rebecca

    2017-08-01

    Peripherally inserted central venous catheters (PICCs) are now commonly used for central access in the intensive care unit (ICU) setting; however, there is a paucity of data evaluating the complication rates associated with these lines. We performed a retrospective review of all PICCs placed in the inpatient setting at our institution during a 1-year period from January 2013 to December 2013. These were divided into two groups: those placed at the bedside in the ICU and those placed by interventional radiology in non-ICU patients. Data regarding infectious and thrombotic complications were collected and evaluated. During the study period, 1209 PICC line placements met inclusion criteria and were evaluated; 1038 were placed by interventional radiology in non-ICU patients, and 171 were placed at the bedside in ICU patients. The combined thrombotic and central line associated blood stream infection rate was 6.17 per cent in the non-ICU group and 10.53 per cent in the ICU group (P = 0.035). The thrombotic complication rate was 5.88 per cent in the non-ICU group and 7.60 per cent in the ICU group (P = 0.38), whereas the central line associated blood stream infection rate was 0.29 per cent in the non-ICU group and 2.92 per cent in the ICU group (P = 0.002). This study seems to suggest that PICC lines placed at the bedside in the ICU setting are associated with higher complication rates, in particular infectious complications, than those placed by interventional radiology in non-ICU patients. The routine placement of PICC lines in the ICU settings needs to be reevaluated given these findings.

  15. Patients with restored occlusions. Part III: The effect of occlusal splint therapy and occlusal adjustments on TMJ dysfunction.

    Science.gov (United States)

    Lederman, K H; Clayton, J A

    1983-07-01

    An earlier study of 50 patients with occlusions restored by fixed partial dentures indicated a high percent (68%) of TMJ dysfunction. Occlusal interferences can play a significant role in causing TMJ dysfunction. To determine the significance of occlusal interferences, occlusal splints were placed in 10 of these restored patients who had moderate to severe dysfunction. The PRI was used to detect the presence or absence of TMJ dysfunction. The PRI TMJ dysfunction scores were reduced in all 10 patients after use of the occlusal splint. Five of the patients achieved reproducible tracings (no TMJ dysfunction) during the experiment time of 7 months. The occlusion of two patients was adjusted to eliminate the need for the occlusal splint. Patients who wore the splint 24 hours a day showed a significant (0.0004 level) reduction in TMJ dysfunction. Those patients who did not wear the splint regularly or had high levels of stress had PRI scores that varied. This finding indicates that the occlusal splint is not a treatment, as its removal permits reactivation of the occlusal interference. Resolution of dysfunction did not occur until occlusal interferences were removed. The changes in PRI scores to different dysfunction categories (none, slight, moderate, and severe) for the experimental group were significant at the 0.01 level. A control group of five patients had similar pantographic tracings but no other treatment. Their PRI scores varied, but there was no significant change in PRI scores or dysfunction categories. It was concluded that occlusal interferences were active causes of TMJ dysfunction in 10 of 36 patients in a population with restored occlusions.

  16. A case-control study to identify risk factors for totally implantable central venous port-related bloodstream infection.

    Science.gov (United States)

    Lee, Guk Jin; Hong, Sook Hee; Roh, Sang Young; Park, Sa Rah; Lee, Myung Ah; Chun, Hoo Geun; Hong, Young Seon; Kang, Jin Hyoung; Kim, Sang Il; Kim, Youn Jeong; Chun, Ho Jong; Oh, Jung Suk

    2014-07-01

    To date, the risk factors for central venous port-related bloodstream infection (CVPBSI) in solid cancer patients have not been fully elucidated. We conducted this study in order to determine the risk factors for CVP-BSI in patients with solid cancer. A total of 1,642 patients with solid cancer received an implantable central venous port for delivery of chemotherapy between October 2008 and December 2011 in a single center. CVP-BSI was diagnosed in 66 patients (4%). We selected a control group of 130 patients, who were individually matched with respect to age, sex, and catheter insertion time. CVP-BSI occurred most frequently between September and November (37.9%). The most common pathogen was gram-positive cocci (n=35, 53.0%), followed by fungus (n=14, 21.2%). Multivariate analysis identified monthly catheter-stay as a risk factor for CVP-BSI (p=0.000), however, its risk was lower in primary gastrointestinal cancer than in other cancer (p=0.002). Initial metastatic disease and long catheter-stay were statistically significant factors affecting catheter life span (p=0.005 and p=0.000). Results of multivariate analysis showed that recent transfusion was a risk factor for mortality in patients with CVP-BSI (p=0.047). In analysis of the results with respect to risk factors, prolonged catheter-stay should be avoided as much as possible. It is necessary to be cautious of CVP-BSI in metastatic solid cancer, especially non-gastrointestinal cancer. In addition, avoidance of unnecessary transfusion is essential in order to reduce the mortality of CVP-BSI. Finally, considering the fact that confounding factors may have affected the results, conduct of a well-designed prospective controlled study is warranted.

  17. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    Science.gov (United States)

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  18. ["Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter].

    Science.gov (United States)

    Mutti, Carolina; Fumagalli, Anna; Monni, Pierina; Rancati, Stefania; Rosi, Ivana Maria

    2016-01-01

    . "Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter. Many variables impact on the choice to implant a totally implantable long-term central venous catheter's (Port), in spite of its proven efficacy. The patients' perception is pivotal, and only few qualitative studies dig deep into patients' feelings and experiences. To understand if, and how, the Port affects the patient's life. Qualitative phenomenological study based on semi-structured interviews on a convenience sample of patients implanted a Port, selected in an oncohematology Day Hospital in Milan. The analysis was carried out by three researchers with a phenomenological method. Four main themes, and sub-themes, emerged from twenty interviews. Relief, both physical and psychological; the process of the choice of inserting the Port and the importance of thinking about its positioning since the beginning of the treatment course; the symbol- the device reminds of the disease and its removal is of utmost importance; the technology progresses- the need of trust in the health care personnel and in their competences. The Port improved the patients' quality of life. The study allows some reflections on the need of considering the actual and future conditions of the patient to make a shared and informed choice.

  19. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    Science.gov (United States)

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  20. [Procedure adverse events: nursing care in central venous catheter fracture].

    Science.gov (United States)

    Pérez-Juan, Eva; Maqueda-Palau, Mònica; Romero-Grilo, Cristina; Muñoz-Moles, Yolanda

    2014-01-01

    In a intensive care unit (ICU) there are many factors that can lead to the occurrence of adverse events. A high percentage of these events are associated with the administration of drugs. Diagnostic tests, such as computed tomography, is common in critically ill patients and technique can be performed with injection of contrast agent to enhance the visualization of soft tissue. The contrast is a medication and the nurse is responsible for its proper administration. The management of the critically ill patient is complex. ICU team and radiology shares responsibility for the care and safety of the patient safety during the transfer and performing tests with contrast. The World Health Organisation patient safety strategies, recommends analysing errors and learning from them. Therefore, it was decided to investigate the causes of the category E severity adverse events that occurred in a patient who was admitted to the ICU for septic shock of abdominal origin. An abdominal computed tomography was performed with contrast which was injected through a central venous catheter. The contrast did not appear in the image. What happened? Causal analysis helped to understand what triggered the event. A care plan and an algorithm were drafted to prevent it from happening again, with the following objectives: improving knowledge, skills and promoting positive attitudes towards patient safety, working at primary, secondary and tertiary care levels. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  1. Remifentanil for the insertion and removal of long-term central venous access during monitored anesthesia care.

    LENUS (Irish Health Repository)

    Burlacu, Crina L

    2012-02-01

    STUDY OBJECTIVE: To determine the analgesic efficacy of three different rates of remifentanil infusion in patients undergoing insertion or removal of long-term central venous access devices during monitored anesthesia care and local anesthetic field infiltration. DESIGN: Double-blinded, randomized, controlled study. SETTING: Operating theatre of an University hospital. PATIENTS: 44 unpremedicated, ASA physical status 1 and 2 patients, aged 18-65 years, undergoing insertion or removal of a Port-a-Cath or Hickman catheter. INTERVENTIONS: Patients sedated with a propofol target-controlled infusion were randomly allocated to three groups: Group R25 (n = 14), Group R50 (n = 15), and Group R75 (n = 15), to receive remifentanil 0.025, 0.05, and 0.075 mug\\/kg\\/min, respectively. Rescue remifentanil 0.5 mug\\/kg was administered for pain scores > 3. The remifentanil infusion rate was maintained constant unless respiratory and\\/or cardiovascular unwanted events occurred, whereupon the rate was adjusted in 0.01 mug\\/kg\\/min decrements as necessary. MEASUREMENTS: Pain scores (primary outcome), sedation, and movement scores (secondary outcomes) were assessed during local anesthetic infiltration of the anterior chest wall and 5 other procedural steps. MAIN RESULTS: All infusion rates had equal analgesic efficacy, as shown by comparable pain scores, number of rescue boluses, and number of patients requiring rescue analgesia. Excessive sedation was associated with the highest remifentanil rate such that Group R75 patients were significantly more sedated than Groups R25 or R50 at selective procedural steps (P < 0.05). More Group R75 patients (6\\/15) required remifentanil rate reduction than did patients from Group R50 (1\\/15) or Group R25 (0\\/14), P < 0.01, most commonly because of respiratory depression. CONCLUSIONS: For the insertion or removal of long-term central venous access devices, all three remifentanil infusion rates proved to be equally analgesic

  2. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion: A case report.

    Science.gov (United States)

    Kim, Ji Hong; Kang, Min Ho; Seong, Mincheol; Cho, Heeyoon; Shin, Yong Un

    2018-04-01

    Non-arteritic anterior ischemic optic neuropathy (NAION) is characterized by sudden, painless visual loss and optic disc edema. NAION occurs mainly in the presence of cardiovascular disease and hypercoagulability, mainly in patients over 50 years of age. We experienced a case of NAION associated with central retinal vein occlusion (CRVO) in a young man with no underlying disease. A 46-year-old man was referred to our clinic following a sudden loss of vision in his right eye. The patient exhibited no underlying disease and reported no ongoing medication. Significant visual loss and visual disturbance of the right eye were observed. The pupil of the right eye was enlarged and an afferent pupillary defect was observed. On fundus examination, retinal hemorrhage was observed in the peripheral retina; macular edema was observed in optical coherence tomography analysis. However, optic disc edema was not evident. No abnormal findings were found in routine blood tests for hypercoagulability. After 3 days of steroid intravenous injection, macular edema disappeared and visual acuity was improved, but optic disc edema began to appear. One week later, optic disc edema was evident and visual acuity was significantly reduced; thus, the patient was diagnosed with NAION. In fluorescein angiography, peripheral retinal ischemia was observed, suggesting that CRVO was complicated. Blood tests, including analysis of coagulation factors, were performed again, showing that coagulation factors IX and XI were increased. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion. Systemic steroids were administered. One month later, optic disc edema and retinal hemorrhage gradually diminished and eventually disappeared; however, visual acuity did not recover. In young patients without underlying disease, cases of NAION require careful screening for coagulation disorders. Even if there is no abnormality in the test for routine

  3. Spontaneous fracture of implanted central venous catheters in cancer patients: report of two cases and retrospective analysis of the 'pinch-off sign' as a risk factor

    NARCIS (Netherlands)

    Punt, C. J.; Strijk, S.; van der Hoeven, J. J.; van de Sluis, R.; Verhagen, C. A.

    1995-01-01

    Spontaneous fracture of central venous catheters (CVC) has been reported. It results from repeated compression of the extravasal part of the CVC between the clavicle and the first rib. The so called pinch-off sign (POS) of the CVC as visible on a chest radiograph has been described as a warning for

  4. Complex left profunda femoris vein to renal vein bypass for the management of progressive chronic iliofemoral occlusion.

    Science.gov (United States)

    Anaya-Ayala, Javier E; Adams, Matthew K; Telich-Tarriba, Jose E; Dresser, Kelly L; Ismail, Nyla; Peden, Eric K

    2013-01-01

    Chronic occlusions of the inferior vena cava (IVC) and iliofemoral veins are long-term sequelae of deep venous thrombosis (DVT) that can lead to postthrombotic syndrome (PTS). Patients may present with a wide spectrum of signs and symptoms, ranging from mild discomfort and swelling to severe venous hypertension and ulcerations. We report a 68-year-old man who had a history of left lower extremity DVT after a laminectomy and who developed PTS with nonhealing ulcers. The patient underwent a cross-pubic femorofemoral venous bypass that failed to improve his clinical status. After unsuccessful endovascular attempts for recanalization of the iliofemoral segment, a profunda femoris to IVC bypass was performed. The symptoms recurred 2 years later. Venography revealed restenosis at the caval anastomosis that did not resolve by endovascular means. A surgical revision was performed, and given the quality of the IVC, a jump bypass was created to the left renal vein. The swelling improved and the ulcers healed completely. Twenty-eight months after the complex reconstructions, he remains ulcer-free with mild edema controlled with stockings. Venous reconstructions remain a viable option for patients with symptomatic and recalcitrant nonmalignant obstruction of the large veins. Copyright © 2013 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  5. Une présentation atypique de la maladie cœliaque: l'occlusion de la veine centrale de la rétine

    Science.gov (United States)

    Jomni, Taieb; Bellakhal, Syrine; Abouda, Maher; Abdelaali, Imene; Douggui, Hédi

    2015-01-01

    Parmi les complications thrombotiques de la maladie cœliaque l'occlusion de la veine centrale de la rétine a été exceptionnellement décrite. Nous rapportons l'observation d'une patiente âgée de 27 ans chez qui le diagnostic de maladie cœliaque a été porté dans le cadre du bilan étiologique d'une occlusion de la veine centrale de la rétine. L'interrogatoire ne révélait pas de diarrhée chronique ou de douleurs abdominales. La présence d'un amaigrissement, d'une anémie ferriprive et d'une hypocholestérolémie ont permis l'orientation vers la maladie cœliaque. La positivité des anticorps anti endomysium et la biopsie duodénale montrant l'atrophie villositaire confirmaient ce diagnostic. Le régime sans gluten associé à un traitement par aspirine avait partiellement amélioré l'acuité visuelle chez notre patiente. Cette présentation atypique de la maladie cœliaque souligne la diversité des manifestations extra-digestives au cours de cette maladie et l'intérêt de penser à la maladie cœliaque même lorsque ces manifestations sont inaugurales. PMID:26966496

  6. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    Science.gov (United States)

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Microfluidics for investigating vaso-occlusions in sickle cell disease.

    Science.gov (United States)

    Horton, Renita E

    2017-07-01

    SCD stems from amutation in the beta globin gene. Upon deoxygenation, hemoglobin polymerizes and triggers RBC remodeling. This phenomenon is central to SCD pathogenesis as individuals suffering from the disease are plagued by painful vaso-occlusive crises episodes. These episodes are the result of a combination of processes including inflammation, thrombosis, and blood cell adhesion to the vascular wall which leads to blockages within the vasculature termed vaso-occlusions. Vaso-occlusive episodes deprive tissues of oxygen and are a major contributor to SCD-related complications; unfortunately, the complex mechanisms that contribute to vaso-occlusions are not well understood. Vaso-occlusions can occur in post-capillary venules; hence, the microvasculature is a prime target for SCD therapies. Traditional in vitro systems poorly recapitulate architectural and dynamic flow properties of in vivo systems. However, microfluidic devices can capture features of the native vasculature such as cellular composition, flow, geometry, and ECM presentation. This review, although not comprehensive, highlights microfluidic approaches that aim to improve our current understanding of the pathophysiological mechanisms surrounding SCD. Microfluidic platforms can aid in identifying factors that may contribute to disease severity and can serve as suitable test beds for novel treatment strategies which may improve patient outcomes. © 2017 John Wiley & Sons Ltd.

  8. Usefulness of time-resolved projection MRA on evaluation of hemodynamics in cerebral occlusive diseases

    International Nuclear Information System (INIS)

    Oka, Yoshihisa; Kusunoki, Katsusuke; Nochide, Ichiro; Igase, Keiji; Harada, Hironobu; Sadamoto, Kazuhiko; Nagasawa, Kiyoshi

    2001-01-01

    The usefulness for evaluation of cerebral hemodynamics using time-resolved projection MRA was studied in normal volunteers and patients of cerebrovascular diseases. Six normal volunteers and ten patients with cerebrovascular occlusive diseases including 6 of IC occlusion and 4 of post EC/IC bypass surgery underwent time-resolved projection MRA on a 1.5 T clinical MRI system. Projection angiograms are acquired with 2D-fast SPGR sequence with a time resolution of approximately one image per second, 40 images being acquired consecutively before and after bolus injection Gd-DTPA. And all images were calculated by complex subtraction from the background mask in a work station. In normal volunteers, the quality of images of time-resolved projection MRA was satisfactory. The arteries from internal carotid artery through M2 segment of middle cerebral artery and all major venous systems were well portrayed. In 4 cases of IC occlusion who were assessed the collateral flow through the anterior communicating artery and posterior communicating artery, there were delayed to demonstrate the ipsilateral MCA. However, in 2 cases of IC occlusion that were assessed the collateral flow through leptomeningeal anastomosis, ipsilateral MCA and collateral circulation were not demonstrated. In all patients of post EC/IC bypass surgery, the patency of EC/IC bypass could be evaluated as properly with time-resolved projection MRA as 3D-TOF MRA. Although the temporal and spatial resolutions are insufficient, time-resolved projection MRA was power-full non-invasive method to evaluate the cerebral hemodynamics vis the basal communicating arteries in IC occlusion and identify the patency of EC/IC bypass. (author)

  9. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia.

    Science.gov (United States)

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  10. Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study.

    Science.gov (United States)

    Lanspa, Michael J; Brown, Samuel M; Hirshberg, Eliotte L; Jones, Jason P; Grissom, Colin K

    2012-12-01

    Volume expansion is a common therapeutic intervention in septic shock, although patient response to the intervention is difficult to predict. Central venous pressure (CVP) and shock index have been used independently to guide volume expansion, although their use is questionable. We hypothesize that a combination of these measurements will be useful. In a prospective, observational study, patients with early septic shock received 10-mL/kg volume expansion at their treating physician's discretion after brief initial resuscitation in the emergency department. Central venous pressure and shock index were measured before volume expansion interventions. Cardiac index was measured immediately before and after the volume expansion using transthoracic echocardiography. Hemodynamic response was defined as an increase in a cardiac index of 15% or greater. Thirty-four volume expansions were observed in 25 patients. A CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less individually had a good negative predictive value (83% and 88%, respectively). Of 34 volume expansions, the combination of both a high CVP and a low shock index was extremely unlikely to elicit hemodynamic response (negative predictive value, 93%; P = .02). Volume expansion in patients with early septic shock with a CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less is unlikely to lead to an increase in cardiac index. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. CENTRAL VENOUS CATHETER AS A VASCULAR APPROACH TO HEMODIALYSTS

    Directory of Open Access Journals (Sweden)

    Verica Djordjevic

    2001-03-01

    Full Text Available The application of the central venous catheter (CVC as a temporary orpermanent vascular approach to hemodialysis has been practiced in our Center since1994. So far 30 (12,6% patients have been thus treated. The primary application hasbeen done in 25 patients, namely: the first making of the A V fistula has been done in16, the ABT in 6, while the vascular approach correction in 3 patients. The secondaryapplication has been done in 5 patients. The infection episode incidence concerningthe CVC application is 20 infections per 1.000 patients. This is the upper limitaccording to the data given in the literature (5, rang 3-20. The average duration of thecatheter is 21 + - 13 days (rang 1-47. Two-volume catheters have been used for ajugular approach though less often for a femoral one. The unsuccessful placing due tothe catheter thrombosis has occurred in 4 patients, the catheter drop-out and itsreplacing have been done in 2 patients, while no replacement has happened in onečaše. The treatment has been stopped in one patient. Tn four patients the cerebrovascularinsult has happened after placing the CVC. The mortality rate is 26,6%,that is, K patients, namely: 4 due to cerebrovascular insult, one due to lung emboly,one due to heart weakness and one due to the sepsis from the V fistula. One patientdied at home for unknown reason. A high infection episode incidence rate is related toinadequate patients' placing so that their location in the rooms for intensive care is away of reducing it. It is necessary to provide for general aseptic procedure at work aswell as for betterment of the accompanying procedures (hemoculture, antibiograms,sterilization in order to maintain a safe catheter function.

  12. Current situation regarding central venous port implantation procedures and complications: a questionnaire-based survey of 11,693 implantations in Japan.

    Science.gov (United States)

    Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi

    2016-12-01

    We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.

  13. Fatal central venous air embolism: a rare complication of esophageal dilation by rendezvous.

    Science.gov (United States)

    Zald, Philip B; Andersen, Peter E

    2011-03-01

    Esophageal dilation by rendezvous is a useful technique for the treatment of complicated esophageal strictures. We present a case of a 74-year-old man with chronic dysphagia caused by a complete cervical esophageal stricture that developed after external beam radiotherapy for treatment of papillary thyroid carcinoma. During attempted dilation using the rendezvous technique, the patient suffered a fatal pulmonary air embolism. The technique of esophageal dilation by rendezvous, complications, and risk factors for development of venous air embolism are discussed. To the best of our knowledge, this is the first report in the literature of fatal venous air embolism after dilation by rendezvous. Copyright © 2009 Wiley Periodicals, Inc.

  14. Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi; Minami, Tetsuya; Shinmura, Rieko; Ito, Chiharu; Takamatsu, Shigeyuki; Kobayashi, Miki; Ushiogi, Yashuyuki

    2005-01-01

    We retrospectively evaluated the usefulness of both arterial and venous access with the pull-through technique in endovascular treatment of totally occluded Brescia-Cimino fistulas. We treated 26 patients (17 men, 9 women; age range 43-82 years, mean age 66 years) with occluded Brescia-Cimino fistulas. First, the occluded segment was traversed from the antegrade brachial arterial access using a microcatheter-guidewire system. Second, the vein was retrogradely punctured after confirmation of all diseased segments, and a 0.014- or 0.016-inch guidewire was pulled through the venous access when the occluded segment was long. All interventions including thrombolysis, thromboaspiration, angioplasty, and stent placement were performed via the venous access. The occlusion was successfully crossed via the brachial arterial access in 23 patients (88%). In 2 patients it was done from the venous approach. In the remaining patient it was not possible to traverse the occluded segment. The pull-through technique was successful in all 19 attempts. Clinical success was achieved in 96%, the primary patency rates at 6, 12, and 18 months were 83%, 78%, and 69%, the primary assisted patency rates were 92%, 92%, and 72%, and the secondary patency rates were 92%, 92%, and 92%, respectively. Minor complications in 5 patients included venous perforation in 2 (8%), venous rupture in 1 (4%), and regional hematoma in 2 (8%). Our study suggests that endovascular treatments with both arterial and venous access using the pull-through technique are highly effective in restoring function in totally occluded Brescia-Cimino fistulas

  15. Parenchymal abnormalities in cerebral venous thrombosis: findings of magnetic resonance imaging and magnetic resonance angiography

    International Nuclear Information System (INIS)

    Ferreira, Clecia Santos; Pellini, Marcos; Boasquevisque, Edson; Souza, Luis Alberto M. de

    2006-01-01

    Objective: to determine the frequency and localization of parenchymal abnormalities in cerebral venous thrombosis on magnetic resonance imaging and magnetic resonance angiography as well as their correlation with the territory and affected venous drainage. Materials and methods: retrospective analysis (1996 to 2004) of 21 patients (3 male and 18 female) age range between 3 and 82 years (mean 40 years, median 36 years) with clinical and radiological diagnosis of cerebral venous thrombosis on magnetic resonance imaging and magnetic resonance angiography in 2D PC, 3D PC and contrast-enhanced 3D TOF sequences. The statistical analysis was performed with the qui-square test. Four patients had follow-up exams and three patients underwent digital subtraction angiography. Results: main predisposing factors were: infection, use of oral contraceptives, hormone replacement therapy and collagenosis. Predominant symptoms included: focal deficit, headache, alteration of consciousness level and seizures. Most frequent parenchymal manifestations were: cortical/subcortical edema or infarct, venous congestion and collateral circulation, meningeal enhancement and thalamic and basal ganglia edema or infarct. Occlusion occurred mainly in superior sagittal, left transverse, left sigmoid and straight sinuses. Cavernous sinus and cortical veins thrombosis are uncommon events. Conclusion: cerebral venous thrombosis is an uncommon cause of stroke, with favorable prognosis because of its reversibility. Diagnosis is highly dependent on the radiologist capacity to recognize the presentations of this disease, principally in cases where the diagnosis is suggested by parenchymal abnormalities rather than necessarily by visualization of the thrombus itself. An accurate and rapid diagnosis allows an immediate treatment, reducing the morbidity and mortality rates. (author)

  16. Validation of a novel venous duplex ultrasound objective structured assessment of technical skills for the assessment of venous reflux.

    Science.gov (United States)

    Jaffer, Usman; Normahani, Pasha; Lackenby, Kimberly; Aslam, Mohammed; Standfield, Nigel J

    2015-01-01

    Duplex ultrasound measurement of reflux time is central to the diagnosis of venous incompetence. We have developed an assessment tool for Duplex measurement of venous reflux for both simulator and patient-based training. A novel assessment tool, Venous Duplex Ultrasound Assessment of Technical Skills (V-DUOSATS), was developed. A modified DUOSATS was used for simulator training. Participants of varying skill level were invited to viewed an instructional video and were allowed ample time to familiarize with the Duplex equipment. Attempts made by the participants were recorded and independently assessed by 3 expert assessors and 5 novice assessors using the modified V-DUOSATS. "Global" assessment was also done by expert assessors on a 4-point Likert scale. Content, construct, and concurrent validities as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. Receiver operator characteristic analysis-established cut points of 19/22 and 21/30 were most appropriate for simulator and patient-based assessment, respectively. We have validated a novel assessment tool for Duplex venous reflux measurement. Further work is required to establish transference validity of simulator training to improve skill in scanning patients. We have developed and validated V-DUOSATS for simulator training. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. Nampt/PBEF/visfatin serum levels: a new biomarker for retinal blood vessel occlusions

    Directory of Open Access Journals (Sweden)

    Kaja S

    2015-04-01

    Full Text Available Simon Kaja,1,* Anna A Shah,1,* Shamim A Haji,1,* Krishna B Patel,1 Yuliya Naumchuk,1 Alexander Zabaneh,1 Bryan C Gerdes,1 Nancy Kunjukunju,1 Nelson R Sabates,1 Michael A Cassell,1 Ron K Lord,1 Kevin P Pikey,1 Abraham Poulose,1 Peter Koulen1,21Vision Research Center, Department of Ophthalmology, 2Department of Basic Medical Science, School of Medicine, University of Missouri – Kansas City, Kansas City, MO, USA*These authors contributed equally to this workAbstract: The main objective of the study was to quantify serum levels of nicotinamide phosphoribosyltransferase (Nampt/pre-B-Cell colony-enhancing factor 1/visfatin in subjects with a history of retinal vascular occlusions (RVOs, disease conditions characterized by pronounced ischemia, and metabolic energy deficits. A case–control study of 18 subjects with a history of RVO as well as six healthy volunteers is presented. Serum Nampt levels were quantified using a commercially available enzyme-linked immunosorbent assay kit. Serum Nampt levels were 79% lower in patients with a history of RVO compared with that in healthy volunteers (P<0.05. There was no statistically significant difference among the types of RVOs, specifically branch retinal vein occlusions (n=7, central retinal vein occlusions (n=5, hemiretinal vein occlusions (n=3, and central retinal artery occlusions (n=3; P=0.69. Further studies are needed to establish the temporal kinetics of Nampt expression and to determine whether Nampt may represent a novel biomarker to identify at-risk populations, or whether it is a druggable target with the potential to ameliorate the long-term complications associated with the condition, ie, macular edema, macular ischemia, neovascularization, and permanent loss of vision.Keywords: Nampt, PBEF, visfatin, nicotinamide phosphoribosyltransferase, pre-B-cell colony-enhancing factor, retinal artery occlusion, retinal vein occlusion, biomarker, retina, vasculature

  18. Investigation of retinal morphology alterations using spectral domain optical coherence tomography in a mouse model of retinal branch and central retinal vein occlusion.

    Directory of Open Access Journals (Sweden)

    Andreas Ebneter

    Full Text Available Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001 compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001. Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions.

  19. Endovascular therapy for chronic cerebrospinal venous insufficiency in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Marc A. Lazzaro

    2011-07-01

    Full Text Available Recent reports have emerged suggesting that multiple sclerosis (MS may be due to abnormal venous outflow from the central nervous system, termed Chronic Cerebrospinal Venous Insufficiency (CCSVI. These reports have generated strong interest and controversy over the prospect of a treatable cause of this chronic debilitating disease. This review aims to describe the proposed association between CCSVI and MS, summarize the current data, and discuss the role of endovascular therapy and the need for rigorous randomized clinical trials to evaluate this association and treatment.

  20. Hepatic telangiectasia in Osler's disease treated with arterial embolization

    Energy Technology Data Exchange (ETDEWEB)

    Goethlin, J H; Nordgard, K; Jonsson, K; Nyman, U

    1982-02-01

    Hepatic hereditary telangiectasia in 2 females was treated with hepatic artery embolization. In one patient both peripheral and central arterial occlusion was performed; the patient died of massive gastro-intestinal bleeding 2 months later. Autopsy showed extensive regions with necrosis in the right liver lobe. In the next patient only central occlusion of the right hepatic artery was performed and the arterio-venous shunting in the left liver lobe left remaining. After a long reconvalescence period the patient recovered completely. It is advocated to centrally occlude only that hepatic artery supplying the most affected parts of the liver in Osler's disease. Thus extensive necrosis with possible ensuing death may be avoided.

  1. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  2. Resuscitation by hyperbaric exposure from a venous gas emboli following laparoscopic surgery

    DEFF Research Database (Denmark)

    Kjeld, Thomas; Hansen, Egon G; Holler, Nana G

    2012-01-01

    Venous gas embolism is common after laparoscopic surgery but is only rarely of clinical relevance. We present a 52 year old woman undergoing laparoscopic treatment for liver cysts, who also underwent cholecystectomy. She was successfully extubated. However, after a few minutes she developed cardiac......, could have contributed to the formation of the intravascular gas emboli. We conclude that persistent resuscitation followed by hyperbaric oxygen treatment after venous gas emboli contributed to the elimination of intravascular bubbles and the favourable outcome for the patient....... arrest due to a venous carbon dioxide (CO2) embolism as identified by transthoracic echocardiography and aspiration of approximately 7 ml of gas from a central venous catheter. She was resuscitated and subsequently treated with hyperbaric oxygen to reduce the size of remaining gas bubbles. Subsequently...

  3. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  4. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    Directory of Open Access Journals (Sweden)

    Masato Kimura

    2017-01-01

    Full Text Available Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  5. Internal jugular vein thrombosis associated with venous hypoplasia and protein S deficiency revealed by ultrasonography.

    Science.gov (United States)

    Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung

    2011-12-01

    A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.

  6. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  7. Occlusal risk factors associated with temporomandibular disorders in young adults with normal occlusions.

    Science.gov (United States)

    Wang, Chen; Yin, Xinmin

    2012-10-01

    The aim of this study was to characterize occlusal stability in young adults with temporomandibular disorder (TMD). Thirty-one patients (aged 19-31 years) with complete natural dentition and Angle class I occlusion who exhibited TMD were compared with 31 age- and sex-matched healthy control subjects. The occlusal registrations were performed using the T-Scan II occlusal imaging and analysis system. Center of occlusal force, asymmetry index of occlusal force, maximal movement of COF, premature contacts, clusion time, and disclusion time were recorded. Compared with control subjects, TMD subjects had a significantly higher frequency of premature contacts (16/32, 50.0%) and greater bilateral asymmetry in the occlusal force. Furthermore, prolonged clusion time and disclusion time also were observed in TMD subjects. These results suggest that a significant association exists between occlusal stability and TMD in young adults. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Venous hemodynamic changes in lower limb venous disease

    DEFF Research Database (Denmark)

    Lee, Byung Boong; Nicolaides, Andrew N; Myers, Kenneth

    2016-01-01

    ). Their aim was to confirm or dispel long-held hemodynamic principles and to provide a comprehensive review of venous hemodynamic concepts underlying the pathophysiology of lower limb venous disorders, their usefulness for investigating patients and the relevant hemodynamic changes associated with various...... forms of treatment. Chapter 1 is devoted to basic hemodynamic concepts and normal venous physiology. Chapter 2 presents the mechanism and magnitude of hemodynamic changes in acute deep vein thrombosis indicating their pathophysiological and clinical significance. Chapter 3 describes the hemodynamic...... changes that occur in different classes of chronic venous disease and their relation to the anatomic extent of disease in the macrocirculation and microcirculation. The next four chapters (Chapters 4-7) describe the hemodynamic changes resulting from treatment by compression using different materials...

  9. Diagnosis of deep venous thrombosis by radioisotopic phlebography

    International Nuclear Information System (INIS)

    Araujo, Antonio Luiz de

    1993-01-01

    The author studied 20 patients with deep venous thrombosis of members (one of them attacked on both arms), from various etiologies, by mean radioisotopic phlebography, in the Vascular Diseases, Radiology and Nuclear Medicine Services of Army Central Hospital (Rio de Janeiro, Brazil) from january 1988 to june 1990. The years old was 18 to 72. The cause most frequency of deep venous thrombosis was idiopathic (seven cases 33.3%). The presence of clot by radionuclide marker in all cases, 16 observations (76.2%) in the lower members and five in the upper extremities (23.9%); 17 cases (85%) also were a conventional venography and his images were confirmed. The diagnostic of deep venous thrombosis from 99m T c MAA (macro aggregate of albumin tagged with technetium) should always de complemented by pulmonary mapping, tracking possible silent emboli. Permit as well repetitions evolutionary until daily and using in patients with history of allergy to radiologic contrast because has not complication. (author)

  10. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-03-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  11. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-01-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  12. Constriction of collateral arteries induced by "head-up tilt" in patients with occlusive arterial disease of the legs

    DEFF Research Database (Denmark)

    Agerskov, K; Henriksen, O; Tønnesen, K H

    1981-01-01

    The effect of head-up tilt on leg blood flow and segmental arterial blood pressures was studied in 21 patients with occlusion or severe stenosis of the common or superficial femoral artery. Arterial pressure was measured directly in the brachial artery, common femoral artery and popliteal artery....... Relative change in blood flow in the leg during tilt was estimated by changes in arterio-venous oxygen differences and by the indicator dilution technique in nine patients. Head-up tilt caused a decrease in leg blood flow of 36% corresponding to an increase in total vascular resistance of 57%. Tilt did...... not change the pressure gradient from femoral to popliteal artery in the patients with occlusion of the superficial femoral artery, indicating that the flow resistance offered by the collateral arteries had increased. In a bilateral sympathectomised patient the increase in collateral resistance was almost...

  13. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    Science.gov (United States)

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. [Technical criteria of central venous catheters: Anaesthesiologist/intensivist and pharmacist opinions].

    Science.gov (United States)

    Novais, T; Cabelguenne, D; Jolivet, F; Nouvel, M; Wallet, F; Piriou, V

    2015-11-01

    The lack of technical information from suppliers and from the literature, a wide variety of features and the absence of medical device reference document explain the difficulty for medical and pharmaceutical staffs to choose a central venous catheter (CVC). The aim of this study was to establish the specifications to choose a CVC according to the clinician needs. An analysis of suppliers' technical documentation and a literature review was performed to identify criteria and to collect them in a questionnaire to conduct semi-structured interviews between 1 pharmacist and 5 anaesthesiologists/intensivists. With these interviews, the technical criteria were classified according to their importance in 3 levels. Thirteen technical criteria were identified after reading the technical documents and the literature. Among them, 8 were classified as "essential criteria" (level I) by the physicians: J-shaped guide, one clamp on each way, identified lumen, radiopacity, graduation every centimeter by 5 to 20 cm from the distal extremity, a length of 15 to 25 cm, a single-lumen catheter with a 14 to 16G way and a three-lumen catheter with 14 to 18G way. Finally, three criteria were classified as "intermediate criteria" (level II) and two as "optional criteria" (level III). This collaborative approach allowed to reference new medical devices according to the clinicians needs. These CVC are a mean to respect guidelines for physicians and nurses and to secure the patient's care. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Antibiotic-Impregnated Central Venous Catheters Do Not Change Antibiotic Resistance Patterns.

    Science.gov (United States)

    Turnbull, Isaiah R; Buckman, Sara A; Horn, Christopher B; Bochicchio, Grant V; Mazuski, John E

    2018-01-01

    Antibiotic-impregnated central venous catheters (CVCs) decrease the incidence of infection in high-risk patients. However, use of these catheters carries the hypothetical risk of inducing antibiotic resistance. We hypothesized that routine use of minocycline and rifampin-impregnated catheters (MR-CVC) in a single intensive care unit (ICU) would change the resistance profile for Staphylococcus aureus. We reviewed antibiotic susceptibilities of S. aureus isolates obtained from blood cultures in a large urban teaching hospital from 2002-2015. Resistance patterns were compared before and after implementation of MR-CVC use in the surgical ICU (SICU) in August 2006. We also compared resistance patterns of S. aureus obtained in other ICUs and in non-ICU patients, in whom MR-CVCs were not used. Data for rifampin, oxacillin, and clindamycin were available for 9,703 cultures; tetracycline resistance data were available for 4,627 cultures. After implementation of MR-CVC use in the SICU, rifampin resistance remained unchanged, with rates the same as in other ICU and non-ICU populations (3%). After six years of use of MR-CVCs in the SICU, the rate of tetracycline resistance was unchanged in all facilities (1%-3%). The use of MR-CVCs was not associated with any change in S. aureus oxacillin-resistance rates in the SICU (66% vs. 60%). However, there was a significant decrease in S. aureus clindamycin resistance (59% vs. 34%; p resistance of S. aureus isolates to rifampin or tetracyclines.

  16. Complement Activation in Arterial and Venous Thrombosis is Mediated by Plasmin

    Directory of Open Access Journals (Sweden)

    Jonathan H. Foley

    2016-03-01

    Full Text Available Thrombus formation leading to vaso-occlusive events is a major cause of death, and involves complex interactions between coagulation, fibrinolytic and innate immune systems. Leukocyte recruitment is a key step, mediated partly by chemotactic complement activation factors C3a and C5a. However, mechanisms mediating C3a/C5a generation during thrombosis have not been studied. In a murine venous thrombosis model, levels of thrombin–antithrombin complexes poorly correlated with C3a and C5a, excluding a central role for thrombin in C3a/C5a production. However, clot weight strongly correlated with C5a, suggesting processes triggered during thrombosis promote C5a generation. Since thrombosis elicits fibrinolysis, we hypothesized that plasmin activates C5 during thrombosis. In vitro, the catalytic efficiency of plasmin-mediated C5a generation greatly exceeded that of thrombin or factor Xa, but was similar to the recognized complement C5 convertases. Plasmin-activated C5 yielded a functional membrane attack complex (MAC. In an arterial thrombosis model, plasminogen activator administration increased C5a levels. Overall, these findings suggest plasmin bridges thrombosis and the immune response by liberating C5a and inducing MAC assembly. These new insights may lead to the development of strategies to limit thrombus formation and/or enhance resolution.

  17. Hypoattenuation on CTA images with large vessel occlusion: timing affects conspicuity

    Energy Technology Data Exchange (ETDEWEB)

    Dave, Prasham [University of Ottawa, MD Program, Faculty of Medicine, Ottawa, ON (Canada); Lum, Cheemun; Thornhill, Rebecca; Chakraborty, Santanu [University of Ottawa, Department of Radiology, Ottawa, ON (Canada); Ottawa Hospital Research Institute, Ottawa, ON (Canada); Dowlatshahi, Dar [Ottawa Hospital Research Institute, Ottawa, ON (Canada); University of Ottawa, Division of Neurology, Department of Medicine, Ottawa, ON (Canada)

    2017-05-15

    Parenchymal hypoattenuation distal to occlusions on CTA source images (CTASI) is perceived because of the differences in tissue contrast compared to normally perfused tissue. This difference in conspicuity can be measured objectively. We evaluated the effect of contrast timing on the conspicuity of ischemic areas. We collected consecutive patients, retrospectively, between 2012 and 2014 with large vessel occlusions that had dynamic multiphase CT angiography (CTA) and CT perfusion (CTP). We identified areas of low cerebral blood volume on CTP maps and drew the region of interest (ROI) on the corresponding CTASI. A second ROI was placed in an area of normally perfused tissue. We evaluated conspicuity by comparing the absolute and relative change in attenuation between ischemic and normally perfused tissue over seven time points. The median absolute and relative conspicuity was greatest at the peak arterial (8.6 HU (IQR 5.1-13.9); 1.15 (1.09-1.26)), notch (9.4 HU (5.8-14.9); 1.17 (1.10-1.27)), and peak venous phases (7.0 HU (3.1-12.7); 1.13 (1.05-1.23)) compared to other portions of the time-attenuation curve (TAC). There was a significant effect of phase on the TAC for the conspicuity of ischemic vs normally perfused areas (P < 0.00001). The conspicuity of ischemic areas distal to a large artery occlusion in acute stroke is dependent on the phase of contrast arrival with dynamic CTASI and is objectively greatest in the mid-phase of the TAC. (orig.)

  18. Progressive central hypovolaemia in man--resulting in a vasovagal syncope?

    DEFF Research Database (Denmark)

    Sander-Jensen, K; Mehlsen, J; Secher, N H

    1987-01-01

    Hypotensive functional haemorrhage induced by venous pooling of blood in the legs has been reported to be characterized by a vasovagal reaction. In the present study these observations were extended by determination of the hormonal profile developed during progressive central hypovolaemia...... and an emotionally induced vasovagal syncope. In six subjects venous pooling resulted in normotensive central hypovolaemia, in one subject hypotensive central hypovolaemia was induced, and one subject experienced an emotionally induced vasovagal syncope. During normotensive central hypovolaemia heart rate increased...... from 58 +/- 4 to 76 +/- 4 beats min-1 (P less than 0.05) and cardiac output fell from 6.1 +/- 0.4 to 4.1 +/- 0.2 1 min-1. Pulse pressure and central venous pressure decreased from 64 +/- 4 to 53 +/- 4 mmHg, and from 8 +/- 2 to 3 +/- 2 mmHg, respectively. Adrenaline and noradrenaline increased from 87...

  19. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  20. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, M.P.; van Oosten, B.W.; de Graaf, W.L.; Seewann, A.M.; Bot, J.C.J.; van den Berg, R.; Uitdehaag, B.M.J.; Polman, C.H.; Barkhof, F.

    2011-01-01

    Background: Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the

  1. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, Mike P.; van Oosten, Bob W.; de Graaf, Wolter L.; Seewann, Alexandra; Bot, Joseph C. J.; van den Berg, René; Uitdehaag, Bernard M. J.; Polman, Chris H.; Barkhof, Frederik

    2011-01-01

    Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the intracerebral

  2. Analysis of the vertebral venous system in relation to cerebral venous drainage on MR angiography

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Sohn, Chul Ho; Kim, Gab Chul; Kim, Yong Sun

    2004-01-01

    In the supine position, cerebral venous drainage occurs primarily through the internal jugular veins, as seen on venous phase cerebral angiography. However, in the erect position, the vertebral venous system represents the major alternative pathway of cerebral venous drainage, while outflow through the internal jugular veins is absent or negligible. The purpose of this study is to evaluate the vertebral venous system and its relationship between the surrounding venous structures using magnetic resonance angiography (MRA) in the case of subjects in the supine position. We retrospectively reviewed the results of 65 patients (M:F = 31: 34, mean age 61.6 years) who underwent multi-phase contrast-enhanced carotid MRA. The imaging studies were performed using a 3.0 T MR unit (TR: 5.2, TE: 1.1, FA: 20, 3.8 thickness, EC: 1). We analyzed the appearance and extent of the vertebral venous system (vertebral venous plexus and vertebral artery venous plexus) and the internal jugular vein on the venous phase images. We also evaluated the main drainage pattern of the cerebral venous drainage and the drainage pattern of the vertebral venous system. The visualized vertebral venous system was defined as either poor, vertebral venous plexus dominant, vertebral artery venous plexus dominant or mixed. In the vertebral venous system, the vertebral artery venous plexus was visualized in 54 cases (83%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 39 cases (72%) and asymmetrical in 15 cases (28%). The extent of the visualized vertebral artery venous plexus was partial in 26 cases (48%) and complete in 28 cases (52%). The vertebral venous plexus was visualized in 62 cases (95%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 43 cases (69%) and asymmetrical in 19 cases (31%). The extent of the visualized vertebral artery venous plexus was partial in 35 cases (56%) and complete in 27 cases (44%). The appearance of the

  3. Risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation.

    Science.gov (United States)

    Atchison, Christie M; Amankwah, Ernest; Wilhelm, Jean; Arlikar, Shilpa; Branchford, Brian R; Stock, Arabela; Streiff, Michael; Takemoto, Clifford; Ayala, Irmel; Everett, Allen; Stapleton, Gary; Jacobs, Marshall L; Jacobs, Jeffrey P; Goldenberg, Neil A

    2018-02-01

    Paediatric hospital-associated venous thromboembolism is a leading quality and safety concern at children's hospitals. The aim of this study was to determine risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation. We conducted a retrospective, case-control study of children admitted to the cardiovascular intensive care unit at Johns Hopkins All Children's Hospital (St. Petersburg, Florida, United States of America) from 2006 to 2013. Hospital-associated venous thromboembolism cases were identified based on ICD-9 discharge codes and validated using radiological record review. We randomly selected two contemporaneous cardiovascular intensive care unit controls without hospital-associated venous thromboembolism for each hospital-associated venous thromboembolism case, and limited the study population to patients who had undergone cardiothoracic surgery or therapeutic cardiac catheterisation. Odds ratios and 95% confidence intervals for associations between putative risk factors and hospital-associated venous thromboembolism were determined using univariate and multivariate logistic regression. Among 2718 admissions to the cardiovascular intensive care unit during the study period, 65 met the criteria for hospital-associated venous thromboembolism (occurrence rate, 2%). Restriction to cases and controls having undergone the procedures of interest yielded a final study population of 57 hospital-associated venous thromboembolism cases and 76 controls. In a multiple logistic regression model, major infection (odds ratio=5.77, 95% confidence interval=1.06-31.4), age ⩽1 year (odds ratio=6.75, 95% confidence interval=1.13-160), and central venous catheterisation (odds ratio=7.36, 95% confidence interval=1.13-47.8) were found to be statistically significant independent risk factors for hospital-associated venous thromboembolism in these children. Patients with all three

  4. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    Science.gov (United States)

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  5. The use of indium-111 labeled platelet scanning for the detection of asymptomatic deep venous thrombosis in a high risk population

    International Nuclear Information System (INIS)

    Siegel, R.S.; Rae, J.L.; Ryan, N.L.; Edwards, C.; Fortune, W.P.; Lewis, R.J.; Reba, R.C.

    1989-01-01

    Five hundred indium-111 labeled platelet imaging studies (387 donor and 113 autologous) were performed postoperatively in 473 patients who had undergone total hip replacement, total knee replacement, or internal fixation of a hip fracture to detect occult deep venous thrombosis. All patients had been anticoagulated prophylactically with aspirin, warfarin sodium (Coumadin), or dextran. Thirty-four possible cases of proximal deep venous thrombosis were identified in 28 asymptomatic patients. To verify the scan results, 31 venograms were performed in 25 patients (three refused). In 21 of 31 cases, totally occlusive thrombi were detected; in 5 cases, partially occlusive thrombi were detected; in 5 cases, no thrombus was seen. No patient who had a negative scan nor any patient who had a verified positive scan (and received appropriate heparin therapy) subsequently developed symptoms or signs of pulmonary embolism. One hundred forty-one indium study patients also underwent Doppler ultrasonography/impedance plethysmography (Doppler/IPG) as a comparative non-invasive technique. In 137 cases, the results of the indium study and Doppler/IPG studies were congruent. The indium study had no false negative results that were detected by Doppler/IPG. No patient had any clinically evident toxicity. These results suggest that indium-111 labeled platelet scanning is a safe, noninvasive means for identifying DVT in high risk patients

  6. CT findings of posterior fossa venous angiomas

    International Nuclear Information System (INIS)

    Satoh, Toru; Kinugasa, Kazushi; Nishimoto, Akira; Nishimoto, Ken.

    1986-01-01

    Three cases of posterior fossa venous angiomas were reported, with some comments on the CT findings. Case 1: A 53-year-old woman was admitted for the further examination of a viral meningitis which had appeared three months before. Neurological examination revealed no abnormality. Vertebral angiography, however, demonstrated numerous fine medullary veins, with an enlarged intraparenchymal draining vein, in the right cerebellum; they drained into the petrosal vein, which was characteristic of venous angioma. On the plain CT, part of the draining vein was identified as a slightly high-density node. A curvilinear draining vein was demonstrated by the enhanced CT. Case 2: A 29-year-old man was admitted complaining of headache, vomiting, and atxia. Neurological examination disclosed truncal ataxia. The enhanced CT demonstrated two distinct nodules on the anterior border of the hematoma in the deep median cerebellum, probably corresponding to the draining veins. On the angiogram, a venous angioma was found in the bilateral cerebellum; it drained into the precentral cerebellar veins and ultimately joined the straight sinus via the precentro-vermo-rectal vein. Case 3: A 4-year-old boy was admitted suffering from headache, vomiting, and ataxia. Neurological examination disclosed a co-ordination disturbance of the left side. The enhanced CT demonstrated a curvilinear structure inside the hematoma. Angiography showed a venous angioma in the left cerebellum which drained into the petrosal vein. Computerized angiotomography delineated the characteristic venous structure on the angiogram as many fine, high-density lines (medullary veins) converging to a large intraparenchymal linear structure (central medullary vein) and then to a superficial cortical vein. In all cases, large intraparenchymal draining veins were identified by the conventional CT. (J.P.N.)

  7. The difficult relationship between occlusal interferences and temporomandibular disorder - insights from animal and human experimental studies.

    Science.gov (United States)

    Xie, Q; Li, X; Xu, X

    2013-04-01

    The aetiology of temporomandibular disorder (TMD) is multifactorial, and numerous studies have addressed that occlusion may be of great importance. However, whether occlusion plays a crucial role in the pathogenesis of TMD remains controversial. Study designs utilising animal models have been used to study the effects of artificial occlusal alterations. Experimental traumatic occlusion affects blood flow in the temporomandibular joint and results in changes in the condylar cartilage, and artificial occlusal interference induces masticatory muscle nociceptive responses that are associated with peripheral sensitisation and lead to central sensitisation, which maintains masticatory muscle hyperalgesia. The possibility that occlusal interference results in TMD has been investigated in humans using a double-blind randomised design. Subjects without a history of TMD show fairly good adaptation to interferences. In contrast, subjects with a history of TMD develop a significant increase in clinical signs and self-report stronger symptoms (occlusal discomfort and chewing difficulties) in response to interferences. Meanwhile, psychological factors appear meaningful for symptomatic responses to artificial interferences in subjects with a history of TMD. Thus, individual differences in vulnerability to occlusal interferences do exist. Although there are advantages and disadvantages to using human and animal occlusal interference models, these approaches are indispensable for discovering the role of occlusion in TMD pathogenesis. © 2013 Blackwell Publishing Ltd.

  8. Risk factors for venous port migration in a single institute in Taiwan.

    Science.gov (United States)

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-14

    An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.

  9. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  10. Colonization of a Central Venous Catheter by the Hyaline Fungus Fusarium solani Species Complex: A Case Report and SEM Imaging

    Directory of Open Access Journals (Sweden)

    Alberto Colombo

    2013-01-01

    Full Text Available The incidence of opportunistic infections by filamentous fungi is increasing partly due to the widespread use of central venous catheters (CVC, indwelling medical devices, and antineoplastic/immunosuppressive drugs. The case of a 13-year-old boy under treatment for acute lymphoblastic leukemia is presented. The boy was readmitted to the Pediatric Ward for intermittent fever of unknown origin. Results of blood cultures drawn from peripheral venous sites or through the CVC were compared. CVC-derived bottles (but not those from peripheral veins yielded hyaline fungi that, based on morphology, were identified as belonging to the Fusarium solani species complex. Gene amplification and direct sequencing of the fungal ITS1 rRNA region and the EF-1alpha gene confirmed the isolate as belonging to the Fusarium solani species complex. Portions of the CVC were analyzed by scanning electron microscopy. Fungi mycelia with long protruding hyphae were seen into the lumen. The firm adhesion of the fungal formation to the inner surface of the catheter was evident. In the absence of systemic infection, catheter removal and prophylactic voriconazole therapy were followed by disappearance of febrile events and recovery. Thus, indwelling catheters are prone to contamination by environmental fungi.

  11. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  12. The effectiveness of occlusal splints for sleep bruxism.

    Science.gov (United States)

    Jagger, Robert

    2008-01-01

    Searches were made using the Cochrane Oral Health Group's Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, LILACS (Latin American & Caribbean Health Sciences Literature), Biblioteca Brasileira de Odontologia, and Dissertations, Theses and Abstracts. Hand searches were made of abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. Randomised controlled trials (RCT) or quasi-RCT were chosen that compared splint therapy concurrently with no treatment, other occlusal appliances, or any other intervention in participants who had sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCT were identified of which five were eventually included. In these, use of an occlusal splint was compared with palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant difference between the occlusal splint and control groups were found in meta-analysis. There is not enough evidence to state that the occlusal splint is effective for treating sleep bruxism. Indication of its use is questionable with regard to sleep outcomes, but there may be some benefit with regard to tooth wear. This systematic review suggests the need for further investigation in more controlled RCT that pay attention to method of allocation, outcome assessment, large sample size, and sufficient duration of followup. The study design must be parallel in order to eliminate

  13. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  14. Successful Retrieval of a Dismembered Central Venous Catheter Stuck to the Right Pulmonary Artery Using a Stepwise Approach

    Directory of Open Access Journals (Sweden)

    Keisuke Nakabayashi

    2016-01-01

    Full Text Available Recent advances in anticancer chemotherapy have resulted in an increase in the number of patients requiring a central venous port catheter, and the incidence of catheter pinch-off syndrome has been increasing. Catheter pinch-off syndrome is a rare and unusual complication. It is difficult to retrieve dislodged catheters from the pulmonary artery, especially if the catheter is stuck to the peripheral pulmonary artery. We herein describe the successful removal of a catheter stuck in the pulmonary artery with a stepwise approach. First, a pigtail catheter was used to tug the dislodged catheter in order to free the unilateral end. Then, a gooseneck snare was used to catch and pull the catheter out of the patient. The key to success is to free the end of the catheter.

  15. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    Science.gov (United States)

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  16. Neurological sequelae from brachiocephalic vein stenosis.

    Science.gov (United States)

    Herzig, David W; Stemer, Andrew B; Bell, Randy S; Liu, Ai-Hsi; Armonda, Rocco A; Bank, William O

    2013-05-01

    Stenosis of central veins (brachiocephalic vein [BCV] and superior vena cava) occurs in 30% of hemodialysis patients, rarely producing intracranial pathology. The authors present the first cases of BCV stenosis causing perimesencephalic subarachnoid hemorrhage and myoclonic epilepsy. In the first case, a 73-year-old man on hemodialysis presented with headache and blurry vision, and was admitted with presumed idiopathic intracranial hypertension after negative CT studies and confirmatory lumbar puncture. The patient mildly improved until hospital Day 3, when he experienced a seizure; emergency CT scans showed perimesencephalic subarachnoid hemorrhage. Cerebral angiography failed to find any vascular abnormality, but demonstrated venous congestion. A fistulogram found left BCV occlusion with jugular reflux. The occlusion could not be reopened percutaneously and required open fistula ligation. Postoperatively, symptoms resolved and the patient remained intact at 7-month follow-up. In the second case, a 67-year-old woman on hemodialysis presented with right arm weakness and myoclonic jerks. Admission MRI revealed subcortical edema and a possible dural arteriovenous fistula. Cerebral angiography showed venous engorgement, but no vascular malformation. A fistulogram found left BCV stenosis with jugular reflux, which was immediately reversed with angioplasty and stent placement. Postprocedure the patient was seizure free, and her strength improved. Seven months later the patient presented in myoclonic status epilepticus, and a fistulogram revealed stent occlusion. Angioplasty successfully reopened the stent and she returned to baseline; she was seizure free at 4-month follow-up. Central venous stenosis is common with hemodialysis, but rarely presents with neurological findings. Prompt recognition and endovascular intervention can restore normal venous drainage and resolve symptoms.

  17. Method for determining the schematic presentation for the cortical sulci and venous system

    International Nuclear Information System (INIS)

    Tatemichi, Nobuhiro; Nakano, Hirotake; Inoue, Yoshiharu.

    1994-01-01

    To realize the corticogram of major sulci and venous system, two different image modalities must be superposed with a minimum error : MRI, MRA and X-Ray angiography. The precise schema of cortical sulci have to become possible with the aid of the IR method of MRI that could clearly identify the sulcal system of the outer and internal surface of the hemisphere. The correspondence of the major venous system of MRI with that of angiography was carried out using several skin markers, bone structures and a deep major venous system. This corticogram was used by the neurosurgeons of the hospital for the electrode placement, the topographical identification of the cortical paroxysms and epilepsy surgery. The best argument for the accuracy of sulcal and venous schema could be offered by somato-sensory evoked potential identifying the central sulcus on the corticogram. (author)

  18. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  19. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    International Nuclear Information System (INIS)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub; Yoon, Ji Young

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16±0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51±0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52±0.25, while in 21 non-traumatic patients it was 1.15±0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT

  20. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub [Dongguk Univ. College of Medicine, Pohang (Korea, Republic of); Yoon, Ji Young [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16{+-}0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51{+-}0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52{+-}0.25, while in 21 non-traumatic patients it was 1.15{+-}0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT.

  1. Venous digital subtraction angiography of the renal arteries in hypertensive patients

    International Nuclear Information System (INIS)

    Brecht, G.; Harder, T.; Franken, T.

    1984-01-01

    We carried out 1890 venous digital subtraction angiograms; this included 113 patients with hypertension in order to exclude renal artery stenosis. On four occasions it was used following surgery on a renal artery. Renal artery stenosis or occlusion was demonstrated in twelve patients, and other vascular diseases or anomalies were found in 24. Two abnormal renal arteries were found following renal artery surgery. The results are compared with smaller groups of patients examined by DSA, and with the results of conventional subtraction methods reported in the literature. In only eight patients (6.8%) DSA provided insufficient information and had to be supplemented by aortography. The method has proved to be a valuable and simple screening method for the investigation of hypertension. (orig.) [de

  2. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  3. Retinal Endovascular Surgery with Tissue Plasminogen Activator Injection for Central Retinal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Yuta Takata

    2018-06-01

    Full Text Available Purpose: To report 2 cases of central retinal artery occlusion (CRAO who underwent retinal endovascular surgery with injection of tissue plasminogen activator (tPA into the retinal artery and showed a remarkable improvement in visual acuity and retinal circulation. Methods: Standard 25-G vitrectomy was performed under local anesthesia. Simultaneously, tPA (80,000 units/mL solution was injected into the retinal artery of the optic disc for 2–3 min using a microneedle. Changes in visual acuity, fundus photography, optical coherence tomography (OCT, fluorescein angiography, and laser speckle flowgraphy (LSFG results were examined. Results: Both cases could be treated within 12 h after the onset of CRAO. Case 1 was a 47-year-old woman. Her visual acuity improved from counting fingers before operation to 0.08 logMAR 1 month after the surgery. However, thinning of the retina at the macula was observed by OCT. Case 2 was a 70-year-old man. His visual acuity improved from counting fingers to 0.1 logMAR 2 months after the surgery. Both fluorescein angiography and LSFG showed improvement in retinal circulation after the surgery in case 2. Conclusions: Retinal endovascular surgery with injection of tPA into the retinal artery was feasible and may be a way to improve visual acuity and retinal circulation when performed in the acute phase of CRAO.

  4. Mensuração de pressão venosa central por meio de cateteres venosos central e periférico: comparação entre os valores obtidos em cães e elaboração de índice de correção Measurement of central venous Pressure by mean of central and peripheric catheters: comparison among the obtained vallues in dogs and elaboration of a correction index

    Directory of Open Access Journals (Sweden)

    Eduardo Santiago Ventura de Aguiar

    2004-12-01

    Full Text Available A Pressão Venosa Central (PVC é a pressão de retorno do sangue ao lado direito do coração e é um importante parâmetro a ser aferido em numerosas situações clínicas, cirúrgicas e experimentais. Para sua realização, utiliza-se um Cateter Venoso Central (CVC aplicado na veia jugular. Em virtude de este ser um aparato intravenoso de alto custo, optou-se por testar a validade de se aferir a PVC com um Cateter Venoso Periférico (CVP aplicado à mesma veia, o qual apresenta custo reduzido. Como resultado, a medida da PVC, tomada com o CVC, deve sofrer um índice de redução, chegando-se, assim, ao valor da PVC que seria obtido com o uso do CVC. Os resultados deste estudo permitem concluir que o CVP é apropriado para a aferição da PVC em cães.The Central Venous Pressure (CVP is a very important pattern for monitorization in many clinical, surgical and experimental procedures, and it reflects the blood pressure that returns to the right heart side. For its measurement a Central Venous Catheter (CVC must be used inside the jugular vein. Because of the high cost of the CVC, an option was taken to measure the CVP with a Peripheric Venous Catheter (PVC inside the jugular vein, with low cost. The CVP measure obtained with the PVC must be subtracted to a reduction index, in this way the measure would correspond to the ones done with the CVC. This study alouds to conclude that the PVC is adequate for CVP measurement in dogs.

  5. Occlusal splints for treating sleep bruxism (tooth grinding).

    Science.gov (United States)

    Macedo, C R; Silva, A B; Machado, M A; Saconato, H; Prado, G F

    2007-10-17

    Sleep bruxism is an oral activity characterised by teeth grinding or clenching during sleep. Several treatments for sleep bruxism have been proposed such as pharmacological, psychological, and dental. To evaluate the effectiveness of occlusal splints for the treatment of sleep bruxism with alternative interventions, placebo or no treatment. We searched the Cochrane Oral Health Group's Trials Register (to May 2007); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 1); MEDLINE (1966 to May 2007); EMBASE (1980 to May 2007); LILACS (1982 to May 2007); Biblioteca Brasileira de Odontologia (1982 to May 2007); Dissertation, Theses and Abstracts (1981 to May 2007); and handsearched abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. We selected randomised or quasi-randomised controlled trials (RCTs), in which splint therapy was compared concurrently to no treatment, other occlusal appliances, or any other intervention in participants with sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCTs were identified. Twenty-four trials were excluded. Five RCTs were included. Occlusal splint was compared to: palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant differences between the occlusal splint and control groups were found in the meta-analyses. There is not sufficient evidence to state that the occlusal splint is

  6. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  7. Evaluation of mupirocin ointment in control of central venous catheter related infections: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Rezaei J

    2009-09-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Central venous catheter (CVC related infections are important complications of cathter application. This study assessed the usefulness of mupirocin in prevention and control of these infections."n"nMethods: In this randomized clinical trial, consecutive surgical patients requiring central venous catheter (for more than 2 days in Amir-Alam Hospital from 2006-2008 were enrolled. Patients were divided in two groups; in "case group" patients received topical mupirocin 2% every 48 hours at the time of insertion of catheter and dressing change and for "control group" mupirocin was not used. All of the patients received chlorhexidine and enoxoparin as complementary treatments. Two groups were comparable in regard of age, sex and risk factors."n"nResults: One hundred eighteen patients enrolled in the study (57 in case and 61 in control group completed the study. 84 catheters in case group and 88 catheters in control group were inserted. The catheters in 90% of patients were inserted in jugular vein. At the end of study 29(16.8% patients (16 in control versus 13 in case group had catheter colonization (p=NS. Catheter related bloodstream infection was observed in 16(9.3% patients (6 in

  8. Assessment of ischemia in acute central retinal vein occlusion from inner retinal reflectivity on spectral domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Browning DJ

    2016-12-01

    Full Text Available David J Browning, Omar S Punjabi, Chong Lee Department of Ophthalmology, Charlotte Eye, Ear, Nose and Throat Associates, P.A., Charlotte, NC, USA Purpose: To determine the relationship between different spectral domain optical coherence tomography (SD-OCT signs of retinal ischemia in acute central retinal vein occlusion (CRVO and whether they predict anterior segment neovascularization (ASNV.Design: Retrospective, observational study.Subjects: Thirty-nine consecutive patients with acute CRVO and 12 months of follow-up.Methods: We graded baseline SD-OCTs for increased reflectivity of the inner retina, loss of definition of inner retinal layers, presence of a prominent middle-limiting membrane (p-MLM sign, and presence of paracentral acute middle maculopathy (PAMM. Graders were masked with respect to all clinical information.Results: The intraclass correlation coefficients (ICCs of grading–regrading by graders 1 and 2 were 0.8104, 95% confidence interval (CI (0.6686, 0.8956, and 0.7986, 95% CI (0.6475, 0.8892, respectively. The intragrader coefficients of repeatability (COR for graders 1 and 2 were 0.94 and 0.92, respectively. The ICC of graders 1 compared with 2 was 0.8039, 95% CI (0.6544, 0.8916. The intergrader COR was 0.80. SD-OCT grades of baseline ischemia were not associated with baseline visual acuity (VA, central subfield mean thickness (CSMT, or relative afferent pupillary defect; 12-month VA, CSMT, change in VA, change in CSMT, number of antivascular endothelial growth factor injections or corticosteroid injections, or proportion of eyes developing ASNV. SD-OCT grades of ischemia did not correlate with the proportion of eyes having the p-MLM sign or PAMM. PAMM and p-MLM are milder signs of ischemia than increased reflectivity of the inner retinal layers. Eyes with PAMM can evolve, losing PAMM and gaining the p-MLM sign.Conclusion: Grading of ischemia from SD-OCT in acute CRVO was repeatable within graders and reproducible across

  9. Elevated lipocalin-2 level in aqueous humor of patients with central retinal vein occlusion.

    Science.gov (United States)

    Koban, Yaran; Sahin, Seda; Boy, Fatih; Kara, Fatih

    2018-03-23

    To assess the concentrations of lipocalin-2 (LCN2) in the serum and the aqueous humor of patients with central retinal vein occlusion (CRVO). The concentrations of LCN2 in the serum and aqueous humor of 16 cataract patients and 16 patients with CRVO with macular edema were compared. Collection of aqueous samples was conducted in the operating theater under sterile conditions and just prior to intravitreal ranibizumab injection or cataract surgery. LCN2 levels in serum and aqueous humor samples were measured using a commercial kit (human lipocalin-2/NGAL PicoKine ELISA Kit, MyBioSource Inc., USA; Catalog No: MBS175829) based on standard sandwich enzyme-linked immunosorbent assay technology. The concentrations of LCN2 in the aqueous humors of the CRVO group were higher than those of the control group (p = 0.021). There was no significant difference in serum LCN2 level between the two groups (p = 0.463). Concentrations of LCN2 in aqueous humor are increased in CRVO. LCN2 may be part of a pro-catabolic phenotype, and it may play an important role in the dreaded complications of CRVO, such as macular edema, macular ischemia, and neovascularization, which lead to blindness.

  10. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    Science.gov (United States)

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  11. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  12. Measurement of cardiac index by transpulmonary thermodilution using an implanted central venous access port: a prospective study in patients scheduled for oncologic high-risk surgery.

    Science.gov (United States)

    Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire

    2014-01-01

    Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (-0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. clinicaltrials.gov NCT02063009.

  13. Primary Antiphospholipid Syndrome: Unusual Presentation in a ...

    African Journals Online (AJOL)

    A 72 year old man with a history of TIAs and stroke with unexplained moderately raised ESR presented a year later with rapid deterioration of vision in his left eye because of central retinal vein occlusion. Primary antiphospholipid syndrome is found in patients with history of arterial or venous thromboembolism, ...

  14. The alternative sigma factor sigma B of Staphylococcus aureus modulates virulence in experimental central venous catheter-related infections.

    Science.gov (United States)

    Lorenz, Udo; Hüttinger, Christian; Schäfer, Tina; Ziebuhr, Wilma; Thiede, Arnulf; Hacker, Jörg; Engelmann, Susanne; Hecker, Michael; Ohlsen, Knut

    2008-03-01

    The impact of the alternative sigma factor sigma B (SigB) on pathogenesis of Staphylococcus aureus is not conclusively clarified. In this study, a central venous catheter (CVC) related model of multiorgan infection was used to investigate the role of SigB for the pathogenesis of S. aureus infections and biofilm formation in vivo. Analysis of two SigB-positive wild-type strains and their isogenic mutants revealed uniformly that the wild-type was significantly more virulent than the SigB-deficient mutant. The observed difference in virulence was apparently not linked to the capability of the strains to form biofilms in vivo since wild-type and mutant strains were able to produce biofilm layers inside of the catheter. The data strongly indicate that the alternative sigma factor SigB plays a role in CVC-associated infections caused by S. aureus.

  15. Venous Ulcers

    Science.gov (United States)

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  16. Updated cannulation technique for tissue plasminogen activator injection into peripapillary retinal vein for central retinal vein occlusion.

    Science.gov (United States)

    van Overdam, Koen A; Missotten, Tom; Spielberg, Leigh H

    2015-12-01

    To update the surgical technique in which a vitrectomy is performed and a retinal branch vein is cannulated and infused with recombinant tissue plasminogen activator (RTPA) to treat central retinal vein occlusion (CRVO) in patients who present with very low visual acuity (VA). Twelve consecutive patients (12 eyes) with CRVO and low VA (logMAR >1.00) at presentation were treated using this method. Cannulation of a peripapillary retinal vein and stable injection of RTPA was successfully performed without surgery-related complications in all 12 eyes. At 12 months after surgery, 8 of the 12 patients (67%) experienced at least one line of improvement in best corrected visual acuity; 6 of the 12 (50%) improved ≥5 lines and 2 (17%) improved ≥8 lines. After additional grid laser and/or subconjunctival or intravitreal corticosteroids, the mean decrease in central foveal thickness was 260 μm, and the mean total macular volume decreased from 12.10 mm(3) to 9.24 mm(3) . Four patients received panretinal photocoagulation to treat either iris neovascularization (n = 2) or neovascularization of the retina and/or disc (n = 2). Administration of RTPA via a peripapillary vein using this updated technique provides an alternative or additional treatment option for patients with very low VA after CRVO. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Pacientes assintomáticos apresentam infecção relacionada ao cateter venoso utilizado para terapia nutricional parenteral Asymptomatic patients present infection related to the central venous catheter used for total parenteral nutrition

    Directory of Open Access Journals (Sweden)

    Juliana Deh Carvalho Machado

    2009-12-01

    Full Text Available OBJETIVO: Avaliar a freqüência de infecção relacionada ao cateter venoso central em pacientes submetidos a terapia nutricional parenteral. MÉTODOS: Foram analisados os cateteres venosos centrais de pacientes em terapia nutricional parenteral que tiveram a indicação de retirada do cateter venoso central por infecção, alta hospitalar, ou trombose. Os pacientes com infecção foram denominados de Grupo 1 e os demais de Grupo 2. RESULTADOS: Não houve diferença estatisticamente significante quanto ao estado nutricional dos 18 pacientes analisados. Foram analisados 28 cateteres e destes 68% estavam infectados, sendo 72% do Grupo 1 e 28% do Grupo 2 (assintomáticos. No Grupo 1, houve infecção sistêmica em 70% dos casos, já no Grupo 2 a hemocultura foi positiva em 17% dos casos. A colonização por Staphylococcus sp. ocorreu em 48% dos casos, seguida de Candida sp. (21%, Enterococcus faecalis (16%, Pseudomonas aerurginosa (10% e Proteus sp.(5%. CONCLUSÃO: A contaminação de cateter venoso central utilizado para terapia nutricional parenteral é freqüente. Mesmo pacientes assintomáticos recebendo nutrição parenteral têm uma incidência maior de infecção por Candida sp. Portanto é necessária a criação de barreiras que impeçam a colonização destes cateteres venosos centrais, a fim de diminuir a morbimortalidade de pacientes dependentes deste tipo de terapia.OBJECTIVE: The aim of this study was to evaluate the frequency of central venous catheter-related infections in hospitalized patients receiving total parenteral nutrition. METHODS: Central venous catheters were analyzed immediately after removal due to infection, hospital discharge or thrombosis. The patients with catheter-related infection were named Group 1 and the other patients were named Group 2. RESULTS: Eighteen patients were studied. There was no statistically significant difference in nutritional status between the two groups. A total of 28 catheters were analyzed

  18. Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.

    Science.gov (United States)

    Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H

    2018-03-14

    The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.

  19. Measurement of total occlusal convergence of 3 different tooth preparations in 4 different planes by dental students.

    Science.gov (United States)

    Yoon, Stephan S; Cheong, Chan; Preisser, John; Jun, Sangho; Chang, Brian M; Wright, Robert F

    2014-08-01

    Total occlusal convergence of crown preparation is an important didactic and clinical concept in dental education. The purpose of this study was to compare the discrepancy between the total occlusal convergence of dental students' typodont crown preparations and the ideal range (4 to 10 degrees) in 3 different regions of the mouth and in 4 different planes of the teeth. The dental students of the Class of 2012 at Harvard School of Dental Medicine were asked to prepare typodont teeth for crowns on 3 different teeth, the maxillary left central incisor (ceramic), mandibular left first molar (complete metal), and mandibular left first premolar (metal ceramic), during their third year preclinical summative examination and the Comprehensive Clinical Examination in their fourth year. Eighteen students prepared 3 teeth in their third and fourth years, whereas 19 students participated only in their fourth year, for a total of 55 sets of 3 teeth. By using custom fit die bases to reproduce the position, a novel procedure of measuring each tooth was accomplished in 4 different planes: the faciolingual, mesiodistal, mesiofacial-distolingual, and mesiolingual-distofacial. The total occlusal convergence of each image was measured with a computer screen protractor. The gingival 2 mm of the axial wall was used to determine the taper of each wall. Linear mixed model analysis was used to estimate and compare the total occlusal convergences of different teeth and planes (α=.05). Bonferroni corrections were used to adjust for post hoc multiple comparisons. The mean total occlusal convergence varied by tooth and plane (2-way interaction; Pplanes; the model-predicted 99% CIs for the total occlusal convergence were as follows: faciolingual (12.7, 19.4), mesiodistal (14.0, 19.3), mesiofacial-distolingual (13,4, 19.4), and mesiolingual-distofacial (13.7, 19.1). For the central incisor, 99% CIs for the total occlusal convergence were (15.9, 24.4) for the faciolingual measurement, providing

  20. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  1. Evaluation of failing hemodialysis fistulas with multidetector CT angiography: comparison of different 3D planes.

    Science.gov (United States)

    Karadeli, E; Tarhan, N C; Ulu, E M Kayahan; Tutar, N U; Basaran, O; Coskun, M; Niron, E A

    2009-01-01

    To evaluate failing hemodialysis fistula complications using 16-detector MDCTA, and to assess the accuracies of different 3D planes. Thirty patients (16 men, 14 women, aged 27-79 years) were referred for hemodialysis access dysfunction. Thirty-one MDCTA exams were done prior to fistulography. For MDCTA, contrast was administered (2mL/kg at 5mL/s) via a peripheral vein in the contralateral arm. Axial MIP, coronal MIP, and VRT images were constructed. Venous complications were evaluated on axial source images, on each 3D plane, and on all-planes together. Results were analyzed using McNemar test. Axial MIP, VRT and all-planes evaluations were most sensitive for fistula site detection (93%). Coronal MIP had the highest sensitivity, specificity and accuracy (35%, 96%, and 85%, respectively) for detecting venous stenosis. VRT and all-planes had the highest sensitivity and accuracy for detecting aneurysms (100%). All-planes and axial MIP were most sensitive for detecting venous occlusion (61% and 54%). Comparisons of detection frequencies for each venous pathology between the five categories of MDCTA revealed no significant differences (P>0.05). MDCTA additionally showed 3 partially thrombosed aneurysms, 4 anastomosis site stenosis and 12 arterial complications. MDCTA overall gives low sensitivity for detection of central vein stenosis and moderate sensitivity for occlusion. For most pathology, all-planes evaluation of MDCTA gives highest sensitivity and accuracy rates when compared to other planes. For venous stenosis and occlusion, MDCTA should be considered when ultrasonography and fistulography are inconclusive. MDCTA is helpful in identifying aneurysms, collaterals, partial venous thromboses and additional arterial, anastomosis site pathologies.

  2. Evaluation of bone loss due to primary occlusal trauma in two experimental models of occlusal overload

    OpenAIRE

    LOPES, Ana Cristina Távora de Albuquerque; TÉO, Mirela Anne Quartaroli; CORRÊA, Mônica Grazieli; ISHIKIRIAMA, Bella Luna Colombini; CAMPOS, Mirella Lindoso Gomes

    2016-01-01

    Abstract Introduction Primary occlusal trauma (OT) is an injury of the periodontium with normal height as a result of occlusal forces which exceed their adaptive capacity. Objective To evaluate, histometrically, the alveolar bone loss in the furcation region of rats experimentally submitted to 2 models of occlusal overload. Material and method 45 animals randomly divided into 3 groups: Occlusal Interference (OI, n = 15) - fixing an orthodontic wire segment on the occlusal surface of the fi...

  3. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  4. Medical management of venous ulcers.

    Science.gov (United States)

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Diagnosis of venous disorders

    International Nuclear Information System (INIS)

    Minar, E.

    1993-01-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.) [de

  6. Cerebral venous angiomas

    International Nuclear Information System (INIS)

    Agnoli, A.L.; Hildebrandt, G.

    1985-01-01

    Clinical symptoms and radiological signs in 15 patients with cerebral venous malformations are presented and the diagnostic problems discussed. The circulation time in combination with cerebral malformations and angiomas of the scalp are described. CT findings in cases of venous malformations of the brain stem are evaluated. Spot-like enhancement, as well as sharply demarcated round shaped enhancement are characteristic for venous angiomas. Cavernous angiomas usually present as homogenous or inhomogenous round shaped enhanced areas. (Author)

  7. Venous ulcers -- self-care

    Science.gov (United States)

    ... surgery to improve blood flow through your veins. Prevention If you are at risk for venous ulcers, take the steps listed above under Wound Care. ... weight if you are overweight. Manage your blood pressure and cholesterol levels. ... Venous leg ulcers - self-care; Venous insufficiency ulcers - self-care; Stasis ...

  8. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  9. Management of venous hypertension following arteriovenous fistula creation for hemodialysis access

    Directory of Open Access Journals (Sweden)

    Varun Mittal

    2016-01-01

    Full Text Available Introduction: Venous hypertension (VH is a distressing complication following the creation of arteriovenous fistula (AVF. The aim of management is to relieve edema with preservation of AVF. Extensive edema increases surgical morbidity with the loss of hemodialysis access. We present our experience in management of VH. Methods: A retrospective study was conducted on 37 patients with VH managed between July 2005 to May 2014. Patient demographics, evaluation, and procedures performed were noted. A successful outcome of management with surgical ligation (SL, angioembolization (AE, balloon dilatation (BD or endovascular stent (EVS was defined by immediate disappearance of thrill and murmur with resolution of edema in the next 48-72 h, no demonstrable flow during check angiogram and resolution of edema with preservation of AVF respectively. Results: All 8 distal AVF had peripheral venous stenosis and were managed with SL in 7 and BD in one patient. In 29 proximal AVF, central and peripheral venous stenosis was present in 16 and 13 patients respectively. SL, AE, BD, and BD with EVS were done in 18, 5, 4, and 3 patients, respectively. All patients had a successful outcome. SL was associated with wound related complications in 11 (29.73 % patients. A total of 7 AVF were salvaged. One had restenosis after BD and was managed with AE. BD, EVS, and AE had no associated morbidity. Conclusions: Management of central and peripheral venous stenosis with VH should be individualized and in selected cases it seems preferable to secure a new access in another limb and close the native AVF in edematous limb for better overall outcome.

  10. CSF Venous Fistulas in Spontaneous Intracranial Hypotension: Imaging Characteristics on Dynamic and CT Myelography.

    Science.gov (United States)

    Kranz, Peter G; Amrhein, Timothy J; Gray, Linda

    2017-12-01

    The objective of this study is to describe the anatomic and imaging features of CSF venous fistulas, which are a recently reported cause of spontaneous intracranial hypotension (SIH). We retrospectively reviewed the records of patients with SIH caused by CSF venous fistulas who received treatment at our institution. The anatomic details of each fistula were recorded. Attenuation of the veins involved by the fistula was compared with that of adjacent control veins on CT myelography (CTM). Visibility of the CSF venous fistula on CTM and a modified conventional myelography technique we refer to as dynamic myelography was also compared. Twenty-two cases of CSF venous fistula were identified. The fistulas were located between T4 and L1. Ninety percent occurred without a concurrent epidural CSF leak. In most cases (82%), the CSF venous fistula originated from a nerve root sleeve diverticulum. On CTM, the abnormal veins associated with the CSF venous fistula were seen in a paravertebral location in 45% of cases, centrally within the epidural venous plexus in 32%, and lateral to the spine in 23%. Differences in attenuation between the fistula veins and the control veins was highly statistically significant (p CSF venous fistulas are an important cause of SIH that can be detected on both CTM and dynamic myelograph y and may occur without an epidural CSF leak. Familiarity with the imaging characteristics of these lesions is critical to providing appropriate treatment to patients with SIH.

  11. [Thrombosis and obstruction associated with central venous lines. Incidence and risk factors].

    Science.gov (United States)

    Vivanco Allende, A; Rey Galán, C; Rodríguez de la Rúa, M V; Alvarez García, F; Medina Villanueva, A; Concha Torre, A; Mayordomo Colunga, J; Martínez Camblor, P

    2013-09-01

    To analyse the incidence of thrombosis and obstruction associated with central venous lines (CVL) inserted in critically ill children, and to determine their risk factors. Prospective observational study in a Pediatric Intensive Care Unit in a University Hospital. An analysis was made of 825 CVL placed in 546 patients. Age, gender, weight, type of catheter (lines, size, and brand), final location of the catheter, mechanical ventilation, type of sedation and analgesia used, initial failure by the doctor to perform CVL catheterization, number of attempts, CVL indication, admission diagnosis, emergency or scheduled procedure, and delayed mechanical complications (DMC). Risk factors for these complications were determined by a multiple regression analysis. A total of 52 cases of DMC, 42 cases of obstruction, and 10 of thrombosis were registered. Obstruction and thrombosis rates were 4.96 and 1.18 per 100 CVL, respectively. The only risk factor independently linked to obstruction was the duration of the CVL (OR 1.05; 95% CI; 1.00-1.10). The number of lines with thrombosis (OR 4.88; 95% CI; 1.26-18.0), as well as parenteral nutrition (OR 4.17; 95% CI; 1.06-16.31) was statistically significant according to bivariate analysis. However, no risk factors for thrombosis were found in the multivariate analysis. Obstruction and thrombosis of CVL inserted in a Pediatric Intensive Care Unit are relatively common complications. CVL duration is an independent risk factor for any line obstruction. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  12. Comparative study to evaluate the accuracy of polyether occlusal bite registration material and occlusal registration wax as a guide for occlusal reduction during tooth preparation.

    Science.gov (United States)

    Joshi, Niranjan; Shetty, Sridhar N; Prasad, Krishna D

    2013-01-01

    The use of different materials and techniques has been studied to decide the safest quantum of reduction of the occlusal surfaces. However, these methods provide limited information as to the actual amount of reduction with limitations in accuracy, accessibility and complexity. The objective of this study was to compare and evaluate the reliability of the most commonly used occlusal registration wax that with polyether bite registration material as a guide for occlusal reduction required during tooth preparations. For the purpose of this study, 25 abutment teeth requiring tooth preparation for fixed prosthesis were selected and tooth preparations carried out. Modeling wax strips of specific dimensions were placed onto the cast of prepared tooth, which was mounted on maximum intercuspation on the articulator and the articulator was closed. The thickness of the wax registration was measured at three zones namely two functional cusps and central fossa. Similar measurements were made using the polyether bite registration material and prosthesis at the same zones. The data was tabulated and was subjected to statistical analysis using anova test and Tukey honestly significant difference test. The differences in thickness between wax record and prosthesis by 0.1346 mm, whereas the difference between polyether and prosthesis was 0.02 mm with a P value of 0.042, which is statistically significant. This means that the wax record was 8.25% larger than the prosthesis while polyether was just 1.27% larger than the prosthesis. The clinical significance of the above analysis is that Ramitec polyether bite registration material is most suitable material when compared with commonly used modeling wax during the tooth preparation.

  13. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series.

    Science.gov (United States)

    Docktor, B L; Sadler, D J; Gray, R R; Saliken, J C; So, C B

    1999-08-01

    The objective was to examine the success and immediate complication rates in a large series of radiologically placed tunneled central venous catheters. We prospectively recorded the success and immediate complication rates in 880 consecutive radiologically placed tunneled central venous catheters. We also recorded the indication for placement, the success of placement, the number of passes required, and whether a double- or single-wall puncture occurred. Hemodialysis was the most common indication for long-term venous access. Venous access was successful in all patients, and catheter placement was successful in 99.4% of patients, with only five failed placements. All patients in whom placement was initially unsuccessful underwent successful placement the same day. All catheters were placed using real-time sonographic guidance. Most were placed in an internal jugular vein, with 87.4% requiring only a single needle pass. The immediate complication rate was only 4.0%, and no major complications occurred. To our knowledge, this series is the largest for which the immediate complication and success rates for radiologically placed central venous catheters have been reported. Our results suggest that radiologic placement of tunneled central venous catheters is a safe and effective alternative to surgery.

  14. Models of the venous system

    DEFF Research Database (Denmark)

    Mehlsen, J

    2000-01-01

    Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models of the v......Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models...... of the venous system require at least three elements: a resistor, a capacitor and an inductor, with the latter being of more importance in the venous than in the arterial system. Non-linearities must be considered in pressure/flow relations in the small venules, during venous collapse, or low flow conditions...

  15. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  16. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters

    DEFF Research Database (Denmark)

    Partovi-Deilami, Kohyar; Nielsen, Jesper K.; Møller, Ann M.

    2016-01-01

    operated by nurse anesthetists for these patients. This prospective observational study with a pre/post design focused on inpatients with DIVA referred for PVC placement, a service provided by nurse anesthetists in most Scandinavian hospitals. The rate of success, procedure time, number of skin punctures......) with ultrasound. Procedure time was reduced from 20 to 10 minutes, discomfort was unchanged, and the median number of skin punctures decreased from 3 to 2. The incidence of central venous catheter placement dropped from 34% to 7%. Implementation of a training program and a mobile service in which nurse......, discomfort, catheter size, location, and incidence of central venous catheter placement are reported before and after implementation of a training program and a mobile service using ultrasound to place difficult-to-place PVCs. The success rate increased from 0% (0 of 33 patients) to 83% (58 of 70 patients...

  17. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Schummer, C.; Sakr, Y.; Reinhart, K. [Jena Univ. (Germany). Klinik fuer Anaestesiologie und Intensivtherapie; Steenbeck, J. [Jena Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Gugel, M. [Zentralklinik Bad Berka (Germany). Klinik fuer Anaesthesiologie und Intensivtherapie; Schummer, W. [SRH Zentralklinikum Suhl (Germany). Dept. of Anaesthesiology and Intensive Care Medicine

    2010-01-15

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  18. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    International Nuclear Information System (INIS)

    Schummer, C.; Sakr, Y.; Reinhart, K.; Steenbeck, J.; Gugel, M.; Schummer, W.

    2010-01-01

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  19. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    Science.gov (United States)

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  20. Placement of a Retrievable Guenther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis

    International Nuclear Information System (INIS)

    Nadkarni, Sanjay; Macdonald, Sumaira; Cleveland, Trevor J.; Gaines, Peter A.

    2002-01-01

    A retrievable Guenther Tulip caval filter(William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances

  1. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    Science.gov (United States)

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  3. The risk of bloodstream infection associated with peripherally inserted central catheters compared with central venous catheters in adults: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; O'Horo, John C; Rogers, Mary A M; Maki, Dennis G; Safdar, Nasia

    2013-09-01

    Peripherally inserted central catheters (PICCs) are associated with central line-associated bloodstream infection (CLABSI). The magnitude of this risk relative to central venous catheters (CVCs) is unknown. To compare risk of CLABSI between PICCs and CVCs. MEDLINE, CinAHL, Scopus, EmBASE, and Cochrane CENTRAL were searched. Full-text studies comparing the risk of CLABSI between PICCs and CVCs were included. Studies involving adults 18 years of age or older who underwent insertion of a PICC or a CVC and reported CLABSI were included in our analysis. Studies were evaluated using the Downs and Black scale for risk of bias. Random effects meta-analyses were used to generate summary estimates of CLABSI risk in patients with PICCs versus CVCs. Of 1,185 studies identified, 23 studies involving 57,250 patients met eligibility criteria. Twenty of 23 eligible studies reported the total number of CLABSI episodes in patients with PICCs and CVCs. Pooled meta-analyses of these studies revealed that PICCs were associated with a lower risk of CLABSI than were CVCs (relative risk [RR], 0.62; 95% confidence interval [CI], 0.40-0.94). Statistical heterogeneity prompted subgroup analysis, which demonstrated that CLABSI reduction was greatest in outpatients (RR [95% CI], 0.22 [0.18-0.27]) compared with hospitalized patients who received PICCs (RR [95% CI], 0.73 [0.54-0.98]). Thirteen of the included 23 studies reported CLABSI per catheter-day. Within these studies, PICC-related CLABSI occurred as frequently as CLABSI from CVCs (incidence rate ratio [95% CI], 0.91 [0.46-1.79]). Only 1 randomized trial met inclusion criteria. CLABSI definition and infection prevention strategies were variably reported. Few studies reported infections by catheter-days. Although PICCs are associated with a lower risk of CLABSI than CVCs in outpatients, hospitalized patients may be just as likely to experience CLABSI with PICCs as with CVCs. Consideration of risks and benefits before PICC use in inpatient

  4. Mesenteric vascular occlusion: a new diagnostic method using a radiolabeled monoclonal antibody reactive with platelets

    International Nuclear Information System (INIS)

    Oster, Z.H.; Som, P.; Zamora, P.O.

    1989-01-01

    A new method for diagnosing mesenteric vaso-occlusive bowel disease with the use of radioimmunoscintigraphy was developed and tested in experimental models of arterial and venous disease, as well as in a model simulating bowel strangulation. The method involves the use of a monoclonal antibody fragment mixture that binds to platelets. The antibody was labeled with technetium-99m, and imaging was performed with a gamma camera in the planar and single photon emission computed tomography modes. This method allowed visualization of areas of ischemia of 1-6 hours duration in bowel loops in 19 dogs 90-180 minutes after injection of the radiolabeled antibody. No bowel radioactivity accumulation occurred in dogs that underwent the same surgical procedure but were given a nonspecific Tc-99m-labeled antibody or in normal dogs given the specific antibody. It appears that the radiolabeled antibody used, which has higher reactivity with human platelets than with dog platelets, will be a good agent for noninvasive diagnosis of mesenteric vaso-occlusive disease in humans. It may also play a role in the intraoperative determination of the extent and location of ischemic bowel segments

  5. Challenges in the Management of Pediatric Central Venous Access Devices in the Community.

    LENUS (Irish Health Repository)

    Wallace, Elaine

    2012-05-25

    Central venous access devices (CVADs) play an essential role in the care of critically ill children. Significant challenges exist for teams in managing CVADs particularly in a community setting. The authors aimed to assess the experience of general practitioners (GPs) caring for children with CVADs. From 200 CVADs inserted in a pediatric hospital in 2009, 50 patients were randomly selected and 44 GPs were forwarded a questionnaire. Twenty (46%) GPs responded. The main reasons (n = 22) for using CVADs were medication administration (n = 11), nutrition (n = 6), and blood sampling (n = 5). Thirteen (65%) GPs had no education in CVAD management and 14 (70%) were unaware of existing guidelines. Those identified by GPs as having primary responsibility for care of CVADs in the community included hospital\\/pediatric teams (n = 9), parents (n = 3), GPs (n = 2), public health nurses (n = 1), and palliative care ("home care") teams (n = 1). The main challenges (n = 15) identified by GPs were lack of education (n = 4), line management difficulties (n = 3), infection risk (n = 3), infrequent exposure to CVADs (n = 3), and poor communication (n = 1). GPs felt that these challenges could be addressed through: education (n = 8), increased manpower and community support (n = 1), and improved communication (n = 1). This study highlights the inconsistency and challenges for GPs surrounding CVAD use in children. Further education and support is necessary to assist GPs in their use particularly when providing end-of-life care for children in the community.

  6. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    Science.gov (United States)

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  7. Implantable central venous chemoport: camparision of results according to approach routes and methods

    International Nuclear Information System (INIS)

    Shin, Byung Suck; Ahn, Moon Sang

    2003-01-01

    To evaluate the results and complications of placement of implantable port according to approach routes and methods. Between April 2001 and October 2002, a total of 103 implantable chemoport was placed in 95 patients for chemotherapy using preconnected type (n=39) and attachable type (n=64). Puncture sites were left subclavian vein (n=35), right subclavian vein (n=5), left internal jugular vein (n=9), right internal jugular vein (n=54). We evaluated duration of catheterization days, complications according to approach routes and methods. Implantable chemoport was placed successfully in all cases. Duration of catheterization ranged from 8 to 554 days(mean 159, total 17,872 catheter days). Procedure related complications occurred transient pulmonary air embolism (n=1), small hematoma (n=1) and malposition in using preconnected type (n=2). Late complications occurred catheter migration (n=5), catheter malfunction (n=3), occlusion (n=1) and infection (n=11). Among them 15 chemoport was removed (14.5%). Catheter migration was occured via subclavian vein in all cases (13%, p=.008). Infection developed in 10.7% of patients(0.61 per 1000 catheter days). There were no catheter-related central vein thrombosis. Implantation of chemoport is a safe procedure. Choice of right internal jugular vein than subclavian vain vein for puncture site has less complications. And selection of attachable type of chemoport is convenient than preconnected type. Adequate care of chemoport is essential for long patency

  8. Prophylaxis of Venous Thrombosis.

    Science.gov (United States)

    Goldhaber, Samuel Z.

    2001-06-01

    Mechanical measures such as graduated compression stockings and intermittent compression boots are available for venous thrombosis prophylaxis, but compliance may be limited. Plantar venous pneumatic compression devices have attained widespread acceptance by both patients and nurses because of their comfort and compact size, but their track record for efficacy is poor. Inferior vena cava filters prevent pulmonary embolism, but do not halt the thrombotic process or prevent venous thrombosis. Pharmacologic prophylaxis traditionally has relied upon minidose unfractionated heparin; however, re-examination is warranted in the face of increasingly ill and complex patients. My opinion is that small, fixed doses of once-daily low molecular weight heparin will eventually replace minidose unfractionated heparin as the standard pharmacologic prophylaxis regimen for most surgical and medical patients. Prolongation of prophylaxis after hospital discharge should receive increased emphasis. Most patients being transferred to a skilled nursing facility should receive venous thromboembolism prophylaxis. Similarly, most patients undergoing total hip or knee replacement should receive prolonged preventive regimens, with at least 1 month of anticoagulation. Despite advances, certain aspects of venous thrombosis prophylaxis remain problematic. First, a surprisingly high number of hospitalized patients develop venous thrombosis because of failed (rather than omitted) prophylaxis. Second, many patients in intensive care have a combination of peripheral vascular disease and active bleeding (usually gastrointestinal) that precludes mechanical or pharmacologic prophylaxis. Third, neurosurgical patients undergoing craniotomy for brain tumors suffer a high rate of venous thrombosis and major pulmonary embolism despite the routine use of combined mechanical and pharmacologic prophylaxis. My opinion is that these three areas, in addition to the hospital culture of prophylaxis, should receive

  9. Complete resolution of transplantation-associated thrombotic microangiopathy and hepatic veno-occlusive disease by defibrotide and plasma exchange.

    Science.gov (United States)

    Beşişik, Sevgi Kalayoğlu; Oztürk, Gülistan Bahat; Calişkan, Yaşar; Sargin, Deniz

    2005-03-01

    Transplantation-associated thrombotic microangiopathy has been associated with significantly reduced survival following allogeneic bone marrow transplantation. We describe here the course of Transplantation-associated thrombotic microangiopathy and hepatic veno-occlusive disease, and response to plasma exchange therapy. A 19-year-old male patient underwent hematopoietic stem cell transplantation (HSCT) from his HLA-matched brother for lymphoblastic lymphoma in the first complete remission. Transplantation-associated thrombotic microangiopathy was diagnosed 17 days after transplantation. At that time, neurological abnormalities were not present. Cyclosporin A (CsA) was discontinued. Hematological stabilization was recorded. On day +20, abdominal distention, painful hepatomegaly and ascites complicated the clinical picture. With a high hepatic venous pressure gradient (18mmH20), veno-occlusive disease of the liver was diagnosed and defibrotide was started, which resulted in a dramatic cessation of pain and increase in urinary output. However, transplantation-associated thrombotic microangiopathy-related symptoms progressed and plasma exchange was instituted, which resulted in worsening of veno-occlusive disease symptoms. He was referred to the Intensive Care Unit due to respiratory compromise and was intubated. Plasma exchange was continued in order after hemofiltration. In three days, fever resolved, hemofiltration could be stopped, and ventilator dependence ended. After 19 aphereses, serum LDH level returned to normal and schistocytes were minimal on microscopic examination of the blood film. Platelet count increase was more gradual. Plasma exchange was discontinued. On the 40th day of defibrotide, all symptoms related with veno-occlusive disease were resolved and defibrotide was stopped. We think that our case is important to establish the relation and management strategy of these two small vessel complications of HSCT.

  10. Unilateral optic disk edema with central retinal artery and vein occlusions as the presenting signs of relapse in acute lymphoblastic leukemia.

    Science.gov (United States)

    Salazar Méndez, R; Fonollá Gil, M

    2014-11-01

    A 39-year-old man with Philadelphia chromosome-positive acute lymphoblastic leukemia (LAL Ph+) developed progressive vision loss to no light perception in his right eye. He had optic disk edema and later developed central artery and vein occlusions. Pan-photocoagulation, as well as radiotherapy of the whole brain were performed in several fractions. Unfortunately the patient died of hematological relapse 4 months later. Optic nerve infiltration may appear as an isolated sign of a leukemia relapse, even before a hematological relapse occurs. Leukemic optic neuropathy is a critical sign, not only for vision, but also for life, and radiotherapy should be immediately performed before irreversible optic nerve damage occurs. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  11. One-year clinical evaluation of nanohybrid resin composite in the restoration of occlusal and proximo-occlusal cavities in Nigeria

    Directory of Open Access Journals (Sweden)

    Lillian Lami Enone

    2017-01-01

    Full Text Available Background: This study aimed to evaluate the clinical performance of nanocomposites in a Nigerian adult population. Resin composites are becoming the preferred direct restorative material in restoring occlusal and proximo-occlusal cavities due to their aesthetic properties and good clinical service. Materials and Methods: This was a clinical study evaluating the clinical performance of a nanohybrid resin composite in the restoration of occlusal and proximo-occlusal cavities in Nigerian adults. This study was done in the Conservative Dentistry Clinic of the Lagos State University Teaching Hospital, Ikeja, from April 2014 to September 2015. The restorations were evaluated immediately at baseline, 3, 6 and 12 months postoperatively for colour match, marginal discolouration, surface roughness, anatomical form, marginal adaptation, retention, post-operative sensitivity and secondary caries using the modified USPHS criteria. Statistical analysis was performed using Fisher's exact test and a 5% level of significance was considered statistically significant. Results: Males had more proximo-occlusal (26.7 than occlusal (6.7 cavities while the females (43.3 had more occlusal cavities. The nanohybrid occlusal restorations had 100% alpha scores at baseline for anatomical form which dropped to 93.3% at 12 months with 6.7% of the restorations scoring Bravo, whereas all nanohybrid proximo-occlusal restorations had 100% alpha scores from baseline to the 12-month review. All occlusal and proximo-occlusal restorations evaluated for surface texture and marginal adaptation had alpha scores at baseline which dropped to 93.3% at 12 months. Conversely, all nanohybrid occlusal and proximo-occlusal restorations scored 100% for colour match and retention, sensitivity and secondary caries from baseline to 12 months. Conclusion: The clinical performance of natural elegance nanohybrid resin composite (Henry Schein® was satisfactory in the restoration of occlusal and

  12. Factors Associated with Continuous Low Dose Heparin Infusion for Central Venous Catheter Patency in Critically Ill Children Worldwide

    Science.gov (United States)

    Onyeama, Sara-Jane N; Hanson, Sheila J; Dasgupta, Mahua; Hoffmann, Raymond G; Faustino, Edward Vincent S

    2016-01-01

    Objective To identify patient, hospital and central venous catheter (CVC) factors that may influence the use of low dose heparin infusion (LDHI) for CVC patency in critically ill-children. Design Secondary analysis of an international multicenter observational study. Setting 59 Pediatric Intensive Care Units (PICUs) over four study dates in 2012, involving 7 countries. Patients Children less than 18 years of age with a CVC, admitted to a participating unit and enrolled in the completed PROTRACT study were included. All overflow patients were excluded. Interventions None. Measurements and Main Results Of the 2,484 patients in the PROTRACT study, 1,312 patients had a CVC. 507 of those patients used LDHI. The frequency of LDHI was compared across various patient, hospital and CVC factors using chi-squared, Mann-Whitney and Fisher's exact tests. In the multivariate analysis, age was not a significant factor for LDHI use. Patients with pulmonary hypertension had decreased LDHI use while those with active surgical or trauma diagnoses had increased LDHI use. All central CVC insertion sites were more likely to use LDHI when compared to peripherally inserted CVCs. The Asia-Pacific region showed increased LDHI use, along with community hospitals and smaller ICUs (LDHI in critically ill children. Further study is needed to evaluate the efficacy and persistence of LDHI use. PMID:27362853

  13. Recurrence of amblyopia after occlusion therapy.

    Science.gov (United States)

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  14. 多波长激光治疗DR合并视网膜中央静脉阻塞%Efficacy observation on multiple wave length laser for diabetic retinopathy and central retinal vein occlusion

    Institute of Scientific and Technical Information of China (English)

    田涛; 刘茹; 彭婧利; 谢丽莲; 邝国平

    2014-01-01

    目的:观察多波长激光治疗糖尿病视网膜病变( diabetic retinopathy,DR)合并视网膜中央静脉阻塞( central retinal vein occlusion, CRVO)的疗效。  方法:选取DR合并CRVO患者95例100眼,采用多波长激光进行光凝治疗。其中黄斑区以氪黄激光治疗为主,包括局部光凝和格栅光凝,周边光凝以氪绿或氪红激光进行治疗。手术前后均进行视力、眼底、荧光素眼底血管造影检查。术后随访12~48 wk。观察比较两组光凝前后视力及黄斑水肿变化,并做统计学分析。  结果:在黄斑格栅光凝组,有效率为61.2%,在黄斑局部光凝组,有效率为86.3%,后者总有效率高于前者,有统计学差异(P  结论:多波长激光治疗DR合并CRVO患者的黄斑水肿安全、有效。%AlM:To observe the efficacy of the multiple wave length laser in treating diabetic retinopathy combined with central retinal vein occlusion. METHODS:Totally 95 cases ( 100 eyes ) with diabetic retinopathy combined with central retinal vein occlusion were treated by multiple wave length laser. Krypton yellow laser was used for macular edema in focal photocoagulation and diffuse photocoagulation. For peripheral retina, krypton green or krypton red laser were used. Visual acuity, slit - lamp biomicroscopy, ophthalmoscopy and fundus fluorescein angiography were performed preoperatively and postoperatively. The patients were followed up for 12 to 48wk. ln this study, change in visual acuity and macular edema were observed in both groups, and statistical analysis was performed. RESULTS: The effective rate was 61. 2% in diffuse macular edema group and 86. 3% in focal macular edema group. The general effective rate of later was higher than the former, while the treatment effect had significant statistical difference (P CONCLUSlON:Multiple wave length laser is an effective and safe way to treat diabetic macular edema of diabetic retinopathy combined with central retinal vein

  15. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    Science.gov (United States)

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Evaluation of bone loss due to primary occlusal trauma in two experimental models of occlusal overload

    Directory of Open Access Journals (Sweden)

    Ana Cristina Távora de Albuquerque LOPES

    Full Text Available Abstract Introduction Primary occlusal trauma (OT is an injury of the periodontium with normal height as a result of occlusal forces which exceed their adaptive capacity. Objective To evaluate, histometrically, the alveolar bone loss in the furcation region of rats experimentally submitted to 2 models of occlusal overload. Material and method 45 animals randomly divided into 3 groups: Occlusal Interference (OI, n = 15 - fixing an orthodontic wire segment on the occlusal surface of the first lower molar; Occlusal Overload (OO, n = 15 - wearing of the cusps of the lower contralateral molars, the second and third molars next to the first molar that had its dimensions maintained; Negative Control (NC, n = 15 - evaluation of the initial dimensions of the periodontal ligament (PL. Five animals / group were sacrificed after 14, 21 and 28 days. Result Intergroup evaluation showed significant bone loss in OI (p0.05. The thickness of the PL remained stable in NC (p>0.05. Conclusion OI and OO were effective in the experimental reproduction of OT, and OI promoted greater alveolar bone loss compared to OO, showing that the impact of occlusal overload in OI increased the extent of the OT injury.

  17. [Underlying conditions associated with the occurrence of retinal vein occlusion].

    Science.gov (United States)

    Tilleul, J; Glacet-Bernard, A; Coscas, G; Soubrane, G; Souied, E H

    2011-05-01

    Conventional risk factors for retinal vein occlusion (RVO) are well established through large epidemiological studies, but triggering factors remain poorly known. A prospective observational study through a questionnaire was completed between January and October 2009 by patients with RVO and controls. Sixty-one patients, including 42 central retinal vein occlusions (CRVO) and 19 branch vein occlusions (BRVO) as well as 118 controls were included. Of the CRVO patients, 77% discovered visual loss upon awakening in contrast to only 33% of BRVO patients. The comparison between RVO and controls showed a higher proportion in the RVO group for (in order of the highest risk): migraine headache (CRVO, 21 %; BRVO, 47 %; controls, 13 %; p=0.008), hypertension (CRVO, 52%; BRVO, 63%; controls, 37%; p=0.012), glaucoma (CRVO, 33%; BRVO, 22%; controls, 16%; p=0.034), antiplatelet or anticoagulant medication (CRVO, 42%; BRVO, 33%; controls, 26%; p=0.074), hyperlipidemia, ocular trauma, sudden deafness, or vertigo. The prevalence was similar in both groups for body mass index, history of phlebitis or peptic ulcer, smoking habits, stress, fasting, dehydration, vasodilator intake, and altitude stay. In addition to the already known risk factors, this study underlines certain underlying conditions or circumstances related to the onset of RVO, such as migraine. In CRVO, three-quarters of the patients on average discovered visual loss upon awakening, which may indicate that nocturnal events may play a significant role in the pathogenesis of the occlusion. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. Occlusion effects, Part I

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    annoyances and the objective measurements were analysed. Persons suffering from tinnitus behaved differently than person without tinnitus. The latter group showed significant relations between the measured occlusion effect, hearing loss and the personal of occlusion. The actual sensation level is also...

  19. Fast Occlusion and Shadow Detection for High Resolution Remote Sensing Image Combined with LIDAR Point Cloud

    Science.gov (United States)

    Hu, X.; Li, X.

    2012-08-01

    The orthophoto is an important component of GIS database and has been applied in many fields. But occlusion and shadow causes the loss of feature information which has a great effect on the quality of images. One of the critical steps in true orthophoto generation is the detection of occlusion and shadow. Nowadays LiDAR can obtain the digital surface model (DSM) directly. Combined with this technology, image occlusion and shadow can be detected automatically. In this paper, the Z-Buffer is applied for occlusion detection. The shadow detection can be regarded as a same problem with occlusion detection considering the angle between the sun and the camera. However, the Z-Buffer algorithm is computationally expensive. And the volume of scanned data and remote sensing images is very large. Efficient algorithm is another challenge. Modern graphics processing unit (GPU) is much more powerful than central processing unit (CPU). We introduce this technology to speed up the Z-Buffer algorithm and get 7 times increase in speed compared with CPU. The results of experiments demonstrate that Z-Buffer algorithm plays well in occlusion and shadow detection combined with high density of point cloud and GPU can speed up the computation significantly.

  20. FAST OCCLUSION AND SHADOW DETECTION FOR HIGH RESOLUTION REMOTE SENSING IMAGE COMBINED WITH LIDAR POINT CLOUD

    Directory of Open Access Journals (Sweden)

    X. Hu

    2012-08-01

    Full Text Available The orthophoto is an important component of GIS database and has been applied in many fields. But occlusion and shadow causes the loss of feature information which has a great effect on the quality of images. One of the critical steps in true orthophoto generation is the detection of occlusion and shadow. Nowadays LiDAR can obtain the digital surface model (DSM directly. Combined with this technology, image occlusion and shadow can be detected automatically. In this paper, the Z-Buffer is applied for occlusion detection. The shadow detection can be regarded as a same problem with occlusion detection considering the angle between the sun and the camera. However, the Z-Buffer algorithm is computationally expensive. And the volume of scanned data and remote sensing images is very large. Efficient algorithm is another challenge. Modern graphics processing unit (GPU is much more powerful than central processing unit (CPU. We introduce this technology to speed up the Z-Buffer algorithm and get 7 times increase in speed compared with CPU. The results of experiments demonstrate that Z-Buffer algorithm plays well in occlusion and shadow detection combined with high density of point cloud and GPU can speed up the computation significantly.

  1. [Temporomandibular joint, occlusion and bruxism].

    Science.gov (United States)

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Tendon vibration attenuates superficial venous vessel response of the resting limb during static arm exercise

    Directory of Open Access Journals (Sweden)

    Ooue Anna

    2012-11-01

    Full Text Available Abstract Background The superficial vein of the resting limb constricts sympathetically during exercise. Central command is the one of the neural mechanisms that controls the cardiovascular response to exercise. However, it is not clear whether central command contributes to venous vessel response during exercise. Tendon vibration during static elbow flexion causes primary muscle spindle afferents, such that a lower central command is required to achieve a given force without altering muscle force. The purpose of this study was therefore to investigate whether a reduction in central command during static exercise with tendon vibration influences the superficial venous vessel response in the resting limb. Methods Eleven subjects performed static elbow flexion at 35% of maximal voluntary contraction with (EX + VIB and without (EX vibration of the biceps brachii tendon. The heart rate, mean arterial pressure, and rating of perceived exertion (RPE in overall and exercising muscle were measured. The cross-sectional area (CSAvein and blood velocity of the basilic vein in the resting upper arm were assessed by ultrasound, and blood flow (BFvein was calculated using both variables. Results Muscle tension during exercise was similar between EX and EX + VIB. However, RPEs at EX + VIB were lower than those at EX (P P vein in the resting limb at EX decreased during exercise from baseline (P vein at EX + VIB did not change during exercise. CSAvein during exercise at EX was smaller than that at EX + VIB (P vein did not change during the protocol under either condition. The decreases in circulatory response and RPEs during EX + VIB, despite identical muscle tension, showed that activation of central command was less during EX + VIB than during EX. Abolishment of the decrease in CSAvein during exercise at EX + VIB may thus have been caused by a lower level of central command at EX + VIB rather than EX. Conclusion Diminished central command induced by tendon

  3. Thyrocervical artery - jugular fistula following internal jugular venous catheterization

    Directory of Open Access Journals (Sweden)

    P P Zachariah

    2014-01-01

    Full Text Available Arteriovenous fistula (AVF is an anomalous communication between an artery and a vein, caused by an iatrogenic or traumatic etiology. Surgically created upper limb AVF remains the preferred vascular access for patients on maintenance hemodialysis. Nonetheless central vein cannulation for hemodialysis is a common procedure done in patients who need hemodialysis. We incidentally detected a thyrocervical artery - jugular fistula in a patient on maintenance hemodialysis. He underwent a successful intra arterial coil embolization of the feeding vessel. Review of literature has shown that, a thyrocervical artery - internal jugular vein arteriovenous fistula following a central venous catheterization has not been reported so far.

  4. Treatment of temporomandibular disorder using occlusal splint

    Directory of Open Access Journals (Sweden)

    Agus Dahlan

    2009-03-01

    Full Text Available Background: Patient suffering from occlusal abnormality is usually detected months or even years when the acute patient visits a dentist, and generally the patient does not receive direct treatment upon his complaints since minimum information is available on this type of treatment. In general, the dentist provides medication only or conducts incorrect selective grinding where in fact, the patient does not feel better from the previous conditions. Purpose: The objective of this study is to discuss the treatment on the dysfunctional temporomandibular joint followed by orofacial pain caused by occlusal disorder using occlusal splint. Case: In this case, a forty three years old male having trouble with the joint on the left jaw followed by orofacial pain caused by occlusal disorder. Case Management: Initial treatment with occlusal splint makes the patient comfortable and recovers from his complaints since the patient could restructure the chewing muscles. This treatment will be more successful if the dentist has the knowledge to use and choose occlusal splint method properly. Occlusal Splint could be used as a supporting therapy and consideration as one of the therapies to avoid the unwanted side effects. The use of occlusal splint is meant as an alternative of the main therapy in overcoming the problem of occlusal splint. Conclusion: Finally, therapy with occlusal splint is very effective as an alternative treatment to handle the dysfunction of temporomandibular joint caused by occlusion.

  5. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    Multiple lumen umbilical venous catheters (ML-UVCs) instead of single lumen UVCs (SL-UVCs) may decrease the need for additional venous lines. Although it seems self-evident that ML-UVCs would reduce the need of additional venous lines, the rates of associated complications might be different. To compare the effectiveness and the safety of ML-UVCs versus SL-UVCs in terms of need of additional vascular access, rates of complications, morbidity and mortality in newborn infants. Randomized and quasi-randomized trials were identified by searching the MEDLINE (1966 - February 2005), EMBASE (1980- February 2005), CINAHL (1982 - February 2005), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2004) and Science Direct (subject area: medicine, journal and abstract database; 1967 to February 2005). Literature search also included a manual search of the abstracts of scientific meetings published in Pediatric Research (1990-2004). Additional citations were sought using references in articles retrieved from searches. Subject experts were contacted to identify the unpublished and ongoing studies. Randomized and quasi-randomized controlled clinical trials comparing safety and efficacy of multiple versus single lumen umbilical venous catheter in neonates (both term and preterm) who were in need of umbilical venous catheter insertion for vascular access in first four weeks of life. Each review author performed data extraction independently and differences were resolved by discussion. The following outcomes were determined: total number of additional peripheral intravenous lines per baby in first week and first four weeks of life, total number of additional percutaneously and surgically placed central venous lines per baby in first four weeks of life, and other safety and efficacy measures. The treatment effect estimators used were RR, RD, and WMD when appropriate along with their 95% CI. If RD was statistically significant, then number

  6. An autopsy case of multiple myeloma with veno-occlusive disease of the liver induced by ionizing radiation

    International Nuclear Information System (INIS)

    Ueno, Hironori; Inagaki, Yasutaka; Yonei, Yoshikazu; Ozawa, Yukako; Atsukawa, Kazuhiro; Tsukada, Nobuhiro; Miyamoto, Kei; Suzuki, Osamu; Kiryu, Yasuyoshi

    1995-01-01

    An autopsy case of multiple myeloma which accompanied radiation-induced veno-occlusion of the liver is presented. A 62-year-old woman with a chief complaint of low back pain was diagnosed as having multiple myeloma. Approximately one year later, the patient was treated with chemotherapy, consisting of VCR, MCNU, ADR, PSL, and CPA, and X-irradiation of 30 Gy to the bilateral trunk for medically intractable rib pain. The irradiation field included the entire liver. Six months later, she was admitted to the hospital due to abdominal distention and massive amounts of ascites. Various examinations failed to make a qualitative diagnosis. Postmortem examination revealed fibrotic occlusion of the central vein which is typical for veno-occlusion disease of the liver. This finding was restricted to the area that was not shielded, irrespective of anatomical structure, strongly suggesting radiation-induced veno-occlusion of the liver. (N.K.)

  7. Hydrogel based occlusion systems

    NARCIS (Netherlands)

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a

  8. ASSOCIATIONS BETWEEN MACULAR EDEMA AND CIRCULATORY STATUS IN EYES WITH RETINAL VEIN OCCLUSION: An Adaptive Optics Scanning Laser Ophthalmoscopy Study.

    Science.gov (United States)

    Iida, Yuto; Muraoka, Yuki; Uji, Akihito; Ooto, Sotaro; Murakami, Tomoaki; Suzuma, Kiyoshi; Tsujikawa, Akitaka; Arichika, Shigeta; Takahashi, Ayako; Miwa, Yuko; Yoshimura, Nagahisa

    2017-10-01

    To investigate associations between parafoveal microcirculatory status and foveal pathomorphology in eyes with macular edema (ME) secondary to retinal vein occlusion (RVO). Ten consecutive patients (10 eyes) with acute retinal vein occlusion were enrolled, 9 eyes of which received intravitreal ranibizumab (IVR) injections. Foveal morphologic changes were examined via optical coherence tomography (OCT), and parafoveal circulatory status was assessed via adaptive optics scanning laser ophthalmoscopy (AO-SLO). The mean parafoveal aggregated erythrocyte velocity (AEV) measured by adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion was 0.99 ± 0.43 mm/second at baseline, which was significantly lower than that of age-matched healthy subjects (1.41 ± 0.28 mm/second, P = 0.042). The longitudinal adaptive optics scanning laser ophthalmoscopy examinations of each patient showed that parafoveal AEV was strongly inversely correlated with optical coherence tomography-measured central foveal thickness (CFT) over the entire observation period. Using parafoveal AEV and central foveal thickness measurements obtained at the first and second examinations, we investigated associations between differences in parafoveal AEV and central foveal thickness, which were significantly and highly correlated (r = -0.84, P = 0.002). Using adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion macular edema, we could quantitatively evaluate the parafoveal AEV. A reduction or an increase in parafoveal AEV may be a clinical marker for the resolution or development/progression of macular edema respectively.

  9. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  10. Impact of ultrasonography on central venous catheter insertion in intensive care

    International Nuclear Information System (INIS)

    Palepu, Gopal B; Deven, Juneja; Subrahmanyam, M; Mohan, S

    2009-01-01

    The insertion of central venous catheters (CVCs) is an integral part of the management of critically ill patients. We aimed to study the impact of ultrasonography (USG) on CVC insertion in intensive care. A prospective study of 450 patients requiring CVC in the intensive care unit (ICU) of a tertiary care hospital. The patients were randomized into two groups: to have CVC insertion with USG-guidance or with the anatomic landmark technique (ALT). Data were collected on patient demographics; operator experience; and method, site and side of insertion. Outcome measures included successful insertion of CVC, number of attempts needed and complications. Internal jugular vein (IJV) cannulation was successful in 177/194 patients (91.2%) using ALT and in 200/205 patients (97.6%) using USG guidance, a significant difference of 6.4% (P = 0.006). Using ALT, 72.7% of cannulations could be accomplished in the first attempt as compared with 84.4% with USG guidance (P = 0.004). The overall complication rate was 28/399 (7%), with 19 (9.8%) complications in the ALT group and 9 (4.4%) in the USG group (age-, sex-, and operator-adjusted OR = 0.35, 95% CI: 0.13–0.96; P = 0.03). For subclavian vein catheterization, the success rate was 26/28 (92.9%) in the ALT group and 17/17 (100%) in the USG group (P = 0.52). Using ALT, 71.4% cannulation could be accomplished in the first attempt as compared with 82.4% under USG guidance (P = 0.49). The overall complication rate was 6/45 (13.3%), with 4 (14.3%) complications in the ALT group and 2 (11.8%) in the USG group (P > 0.99). Real-time USG guidance improves success rates, reduces the number of attempts and decreases the complications associated with CVC insertion, especially for the IJV, and should become the standard of care in intensive care

  11. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures

    Directory of Open Access Journals (Sweden)

    Aguilar F

    2007-01-01

    Full Text Available This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield and a photochromatic flowable composite resin (Tetric Flow Chroma placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars were sealed with each material, isolated (except for the sealed surface and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab. The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove′s total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment - 30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab. The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days. New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way anova and Tukey′s test P < 0.05. Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  12. Protocol for the realization of venous mapping by chronic venous insufficiency in lower limbs under sonographic guide

    International Nuclear Information System (INIS)

    Blanco Rojas, Diego Jose

    2013-01-01

    The current state of knowledge is reviewed with respect to the realization of lower limbs venous mapping. Venous mapping is obtained by the use of color and spectral Doppler ultrasound. Doppler ultrasound has provided a precise graphical representation of the superficial and deep venous systems. The performance of the venous mapping is considered essential for the correct handling of venous diseases. The anatomical and pathophysiological basic concepts are defined to realize the sonographic assessment of the veins of the lower limbs. The required technical aspects are revised for the realization of sonographic exploration of the patient with venous insufficiency. Sonographic findings are characterized to support the diagnostic of venous insufficiency of the lower limbs. The CEAP (clinical-etiologic-anatomic-pathophysiologic) classification is utilized to differentiate forms and degrees of severity of the disorder, and has allowed an interinstitutional comparison in clinical studies, the evaluation of treatment and monitoring of patients. A proposal is designed to perform reports that have served of guide surgical to vascular surgeons [es

  13. Indication, procedure, and choice of the embolisation material in transcatheteral vascular occlusion

    International Nuclear Information System (INIS)

    Vogel, H.; Niemeier, J.; Hamburg Univ.

    1985-01-01

    If it is planned to effect transcatheteral occlusion of vessels, it must be examined whether the relevant vessel should be occluded permanently or temporarily and whether the occlusion should be located centrally in the vascular trunk or in a major twig, or peripherally in the region of the capillaries, arterioles and small vessels. Temporary occlusion with fibrospum is usually sufficient for treating a haemorrhage. Ethibloc or Bucrylate can be employed to shut off an organ and to achieve partial organ necrosis. Arteriovenous connections with a large vascular lumen can be occluded by means of metal particles. Peripherally occluding substances should not be used for embolisations in the gastrointestinal range because of the risk of local necrosis and possible dangerous infection resulting therefrom. To the present day hardly any indications have been found for the use of absolute alcohol. Bucrylate has the drawback, compared against Ethibloc, that the catheter may adhere to the vascular wall. Vessels with a low flow rate should be occluded either by means of balloon catheter or a coaxial catheter system because of the risk of reflux. (orig.) [de

  14. Colorectal cancer with venous tumor thrombosis

    OpenAIRE

    Kensuke Otani; Soichiro Ishihara; Keisuke Hata; Koji Murono; Kazuhito Sasaki; Koji Yasuda; Takeshi Nishikawa; Toshiaki Tanaka; Tomomichi Kiyomatsu; Kazushige Kawai; Hiroaki Nozawa; Hironori Yamaguchi; Toshiaki Watanabe

    2018-01-01

    Summary: Colorectal cancer is seldom accompanied by venous tumor thrombosis, and little is known about the features of venous tumor thrombosis in colorectal cancer. However, some reports show that colorectal cancer patients can develop venous tumor thrombosis and warn clinicians not to overlook this complication. In this report, we perform a review of 43 previously reported cases and investigate the characteristics of colorectal cancer accompanied by venous tumor thrombosis. The histological ...

  15. Postural stability and occlusal status among Japanese elderly.

    Science.gov (United States)

    Song-Yu, Xuan; Rodis, Omar M M; Ogata, Sagiri; Can-Hu, Jin; Nishimura, Michiko; Matsumura, Seishi

    2012-06-01

    There are still no data available on the relationship between postural stability and occlusal status among the elderly. To examine relationships between postural stability and occlusal status through a cohort study among elderly Japanese. Oral examination, occlusal status, postural stability and a questionnaire were conducted and given to 87 community-dwelling Japanese at enrolment. The average occlusal pressure of the female group was statistically higher than the male group while average occlusal pressure and postural stability length were lesser in the group with more remaining teeth. Postural stability area and number of remaining teeth showed statistically significant correlations. Postural stability length was lesser in the group with strong occlusal force. Furthermore, the number of decayed teeth was fewer in the good hygiene group. This study identified a close relationship between occlusal status and postural stability of Japanese older individuals. Occlusal hypofunction was observed more in those with occlusal problems, and a decrease in their occlusal functions resulted in postural instability. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  16. Diagnosis and endovascular treatment of multiple cerebral venous and venous sinuses thrombosis

    International Nuclear Information System (INIS)

    Li Baomin; Zhang Ji; Yin Ling; Huang Xusheng; Jiang Jinli; Liu Jun; Lang Senyang; Zhou Dingbiao; Zhu Ke

    2000-01-01

    Objective: Eighty-five cases with multiple cerebral venous and venous sinuses thrombosis including the diagnosis and endovascular therapy were reported. Methods: The long T2 and short T1 signals in the related regions of multiple venous sinuses on MRI and prolonged blood circulation time of the brain with tortuous dilatation of vein in angiography were the important characteristics for the diagnosis. Of the 85 cases, the treatment procedures were consisted of injecting urokinase intermittently via common carotid artery and intra-sinus contact thrombolysis as well as warfarin intake orally. Results: Intracranial pressure of 80 cases reduced down between 230 and 300 mm H 2 O, and clinical deficits were markedly improved within 10 days. Re-angiography of 18 cases revealed recanalization partly in 5 cases and circulation time appeared near normal i 8 cases during one week after therapy. Conclusions: Combined intraarterial thrombolysis consecutively with general anticoagulation for the treatment of multiple thrombosis in cerebral venous sinuses may be one of the effective means

  17. Comparison of transient arterial occlusion and muscle exercise provocation for assessment of perfusion reserve in skeletal muscle with real-time contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Krix, Martin; Krakowski-Roosen, Holger; Armarteifio, Erick; Fuerstenberger, Susanne; Delorme, Stefan; Kauczor, Hans-Ulrich; Weber, Marc-Andre

    2011-01-01

    Objective: Contrast-enhanced ultrasound (CEUS) is able to quantify muscle perfusion and changes in perfusion due to muscle exercise in real-time. However, reliable measurement of standardized muscle exercise is difficult to perform in clinical examinations. We compared perfusion reserve assessed by CEUS after transient arterial occlusion and exercise to find the most suitable measurement for clinical application. Methods: Contrast pulse sequencing (7 MHz) during continuous IV infusion of SonoVue (4.8 mL/300 s) was used in 8 healthy volunteers to monitor muscle perfusion of the gastrocnemius muscle during transient (1 min) arterial occlusion produced by a thigh cuff of a venous occlusion plethysmograph. Isometric muscle exercise (50% of individual maximum strength for 20 s) was subsequently performed during the same examination, and several CEUS parameters obtained from ultrasound-signal-intensity-time curves and its calculation errors were compared. Results: The mean maximum local blood volume after occlusion was 13.9 [∼mL] (range, 4.5-28.8 [∼mL]), and similar values were measured after sub-maximum exercise 13.8 [∼mL], (range, 4.6-22.2 [∼mL]. The areas under the curve during reperfusion vs. recovery were also similar (515.2 ± 257.5 compared to 482.2 ± 187.5 [∼mL s]) with a strong correlation (r = 0.65), as were the times to maximum (15.3 s vs. 15.9 s), with a significantly smaller variation for the occlusion method (±2.1 s vs. ±9.0 s, p = 0.03). The mean errors for all calculated CEUS parameters were lower for the occlusion method than for the exercise test. Conclusions: CEUS muscle perfusion measurements can be easily performed after transient arterial occlusion. It delivers data which are comparable to CEUS measurements after muscle exercise but with a higher robustness. This method can be easily applied in clinical examination of patients with e.g. PAOD or diabetic microvessel diseases to assess perfusion reserve.

  18. Resuscitative endovascular balloon occlusion of the aorta: promise, practice, and progress?

    Science.gov (United States)

    Perkins, Zane B; Lendrum, Robbie A; Brohi, Karim

    2016-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a minimally invasive damage control procedure for life-threatening abdominal or pelvic haemorrhage. The purpose of this review is to summarize the current understanding and experience with REBOA, outline potential future applications of this technology, and highlight priority areas for further research. REBOA is a feasible method of achieving temporary aortic occlusion and can be performed rapidly, with a high degree of success, in the emergency setting (including at the scene of injury) by appropriately trained clinicians. The procedure supports central perfusion, controls noncompressible haemorrhage, and may improve survival in certain profoundly shocked patient groups; but is also associated with significant risks, including ischaemic tissue damage and procedural complications. Evolutions of this strategy are being explored, with promising proof-of-concept studies in the fields of partial aortic occlusion and the combination of REBOA with extracorporeal support. Noncompressible torso haemorrhage is the leading cause of preventable trauma deaths. The majority of these deaths occur soon after injury, often before any opportunity for definitive haemorrhage control. For a meaningful reduction in trauma mortality, novel methods of rapid haemorrhage control are required.

  19. EARLY AND LATE COMPLICATIONS RELATED TO CENTRAL VENOUS CATHETERS IN HAEMATOLOGICAL MALIGNANCIES: A RETROSPECTIVE ANALYSIS OF 1102 PATIENTS

    Directory of Open Access Journals (Sweden)

    Salvatore Giacomo Morano

    2014-02-01

    Full Text Available Several severe complications may be associated with the use of central venous catheters (CVC. We retrospectively evaluated on a large cohort of patients the incidence of CVC-related early and late complications. From 7/99 to 12/2005, 1102 CVC have been implanted at our Institution in 881 patients with haematological malignancies (142,202 total day number of implanted CVC. Early mechanic complications were 79 (7.2% - 0.55/1,000 days/CVC. Thirty-nine episodes of early infective complications (<1 week from CVC implant occurred (3.5% - 0.3/1000 days/CVC: furthermore, 187 episodes of CVC-related sepsis (17% - 1.3/1000 days/CVC were recorded. There were 29 episodes (2.6% of symptomatic CVC-related thrombotic complications, with a median interval from CVC implant of 60 days (range 7 – 395. The rate of CVC withdrawal due to CVC-related complications was 26%. The incidence of CVC-related complications in our series is in the range reported in the literature, notwithstanding cytopenia often coexisting in haematological patients.

  20. Regional cerebral blood flow using sup 133 Xenon intra-venous technique, 2; Evaluation of regional cerebral blood flow in patients with cerebrovascular ischemic disease

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Masahiro; Teramoto, Shigeyoshi; Moriyama, Tadayoshi (Nagasaki Chuo National Hospital (Japan))

    1990-12-01

    Using the {sup 133}Xenon venous method, we have studied the regional cerebral blood flow (rCBF) in 947 patients with cerebrovascular ischemic disease. In 116 stroke or TIA patients with internal carotid artery occlusion or severe stenosis, their rCBF revealed 48.9 ml/100 g/min on average in the group of one side occlusion, 46.7 ml/100 g/min in the group of both sides occlusion. These values reduced approximately 12%, 16% and 15% of the rCBF in healthy volunteers of same age, respectively. In 28 patients with moya moya disease, their rCBF tended to be higher in younger cases and lower with advanced age. In the majority of the cases, their rCBF was age-dependent with 20{similar to}25 ml/100 g/min below the curve of age-matched rCBF of healthy volunteers. The reduction of rCBF was observed in 69 (48.3%) of 143 cases clinically diagnosed as small vessel disease, in 58 (41.4%) of 140 cases with vertebro-basilar insufficiency and in 23 (44.2%) of 52 cases with syncopal attack compared with the rCBF of healthy volunteers. (author).