WorldWideScience

Sample records for central venous cathether

  1. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  2. Central Venous Access

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Warakaulle, Dinuke R.; Uberoi, Raman

    2007-01-01

    Central venous access plays an important role in the management of an ever-increasing population of patients ranging from those that are critically ill to patients with difficult clinical access. Interventional radiologists are key in delivering this service and should be familiar with the wide range of techniques and catheters now available to them. A comprehensive description of these catheters with regard to indications, technical aspects of catheterization, success rates, and associated early and late complications, as well as a review of various published guidelines on central venous catheter insertion are given in this article

  3. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  4. Central venous obstruction in the thorax

    International Nuclear Information System (INIS)

    Collin, G.; Jones, R.G.; Willis, A.P.

    2015-01-01

    Central venous stenosis and occlusion can occur secondary to a spectrum of conditions ranging from aggressive malignancy to benign extrinsic anatomical compression in otherwise healthy individuals. Irrespective of aetiology, significant morbidity in the acute setting and long term can occur unless prompt accurate diagnosis and appropriate management is initiated, the radiologist being central to both. The present review will provide radiologists with a thorough illustration and explanation of the range of central venous conditions in the thorax (including deep vein thrombosis, thoracic outlet syndrome, haemodialysis, and malignancy related causes), the salient imaging findings and interventional management using case examples from the authors' practice. - Highlights: • We show a range of causes of central venous disease in the thorax. • We provide information about different imaging and management strategies. • We show several cases with successes and complications of endovascular management

  5. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  6. [The unnecessary application of central venous catheterization in surgical patients].

    Science.gov (United States)

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  7. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  8. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  9. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...... (28-36) (median and range) to 34 (30-40) Ohm, mean arterial pressure (MAP) from 79 (70-88) to 86 (80-99) mmHg, heart rate (HR) from 67 (56-71) to 99 (78-119) beats min-1 (p ....05) but thereafter remained stable. In contrast, central venous oxygen saturation showed a linear decrease with time from 0.75 (0.69-0.78) at rest to 0.60 (0.49-0.67) (p measurement of central venous oxygen saturation...

  10. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  11. Central venous stenosis among hemodialysis patients is often not associated with previous central venous catheters.

    Science.gov (United States)

    Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji

    2011-01-01

    It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.

  12. Pediatric central venous access devices: nursing interventions

    Directory of Open Access Journals (Sweden)

    Duffy EA

    2017-05-01

    Full Text Available Elizabeth A Duffy, Kathryn N Nelson Department of Health Behavior and Biological Sciences, The University of Michigan School of Nursing, Ann Arbor, MI, USA Abstract: A central venous catheter (CVC is an indwelling catheter that provides permanent or temporary stable venous access for both acute and chronically ill pediatric patients. These catheters provide stable venous access that can be used for a variety of medical purposes including drawing blood, hemodynamic monitoring, infusion of intravenous medications, infusion of intravenous fluids, chemotherapy, blood products, and parenteral nutrition. Each day, nurses access and care for CVCs in infants, children, and adolescents; the precision of this care can prevent life-threatening complications. The purpose of this review and the case study is to highlight the importance and components of evidence-based nursing practice in pediatric CVC care. A historical perspective of CVC care is provided in conjunction with current national initiatives to improve patient outcomes for children with CVCs. Infection prevention, clinical practice guidelines, quality improvement, and evidence-based care bundles are discussed. Keywords: pediatric nursing, central venous catheters, central line-associated bloodstream infection, care bundles, pediatric case study 

  13. Massive hydrothorax with malpositioned central venous catheter – Ultrasound detection

    Directory of Open Access Journals (Sweden)

    Neha Hasija

    2016-04-01

    Full Text Available Radioimaging is the gold standard for confirmation of the position of central venous catheter as well as its related complications. Use of ultrasound has been proven in guiding central venous cannulations, and it can also be used in detecting related complications. We report a case of a 2 year old child with hydrothorax causing desaturation due to malpositioned central venous catheter diagnosed by ultrasound in the delay for getting a radiograph.

  14. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  15. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    Science.gov (United States)

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  16. Advantages and disadvantages of peripherally inserted central venous catheters (PICC) compared to other central venous lines: a systematic review of the literature.

    Science.gov (United States)

    Johansson, Eva; Hammarskjöld, Fredrik; Lundberg, Dag; Arnlind, Marianne Heibert

    2013-06-01

    The use of central venous lines carries a significant risk for serious complications and high economic costs. Lately, the peripherally inserted central venous catheter (PICC) has gained in popularity due to presumed advantages over other central venous lines. The aim of this systematic literature review was to identify scientific evidence justifying the use of PICC. The literature review was performed according to the principles of Cochrane Collaboration. The electronic literature search included common databases up to March 2011. Only those studies rated as high or moderate quality were used for grading of evidence and conclusions. The search resulted in 827 abstracts, 48 articles were read in full text, and 11 met the inclusion criteria. None of the articles was classified as high quality and two had moderate quality. The results of these two studies indicate that PICC increases the risk for deep venous thrombosis (DVT), but decreases the risk for catheter occlusion. The quality of scientific evidence behind these conclusions, however, was limited. Due to the lack of studies with sufficiently high quality, questions such as early complications, patient satisfaction and costs could not be answered. We conclude that although PICCs are frequently used in oncology, scientific evidence supporting any advantage or disadvantage of PICC when comparing PICC with traditional central venous lines is limited, apart from a tendency towards increased risk for DVT and a decreased risk for catheter occlusion with PICC.

  17. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    International Nuclear Information System (INIS)

    Nicholson, Tony; Ettles, Duncan; Robinson, Graham

    2004-01-01

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred with carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device

  18. Case report: Unilateral conduction hearing loss due to central venous occlusion.

    Science.gov (United States)

    Ribeiro, Phillip; Patel, Swetal; Qazi, Rizwan A

    2016-05-07

    Central venous stenosis is a well-known complication in patients with vascular access for hemodialysis. We report two cases involving patients on hemodialysis with arteriovenous fistulas who developed reversible unilateral conductive hearing loss secondary to critical stenosis of central veins draining the arteriovenous dialysis access. A proposed mechanism for the patients' reversible unilateral hearing loss is pterygoid venous plexus congestion leading to decreased Eustachian tube patency. Endovascular therapy was conducted to treat the stenosis and the hearing loss of both patients was returned to near normal after successful central venous angioplasty.

  19. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    Science.gov (United States)

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  20. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    Science.gov (United States)

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  1. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    Science.gov (United States)

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, pvenous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  2. Central venous obstruction in hemodialysis patients: the usefulness of percutaneous treatment

    International Nuclear Information System (INIS)

    Kim, Cheol Young; Goo, Dong Erk; Kim, Dae Ho; Hong, Hyun Suk; Lee, Hae Kyoung; Choi, Duk Lin; Yang, Sung Boo; Moon, Chul

    2002-01-01

    To analyse the effectiveness of percutaneous treatment of central venous obstruction in patients undergoing hemodialysis. In 100 patients, 107 central venous strictures (56 subclavian (occlusion:21, stenosis:35) and 51 innominate (occlusion:23,stenosis:28)) were assessed, and 170 percutaneous angioplasty procedures were performed. Balloon dilation of the venous lumen was the preferred mode, but if dilation was incomplete we inserted a stent at the site of the stricture. Technical success, procedural complications and the long-term patency rate were evaluated, and the patency difference according to location and degree of stricture, the existence of DM, and any history of central catheter insertion was also determined. We inserted 52 stents in 170 procedures, in 157 (92.4%) of which initial technical success was achieved. Stent migration occurred in two cases and balloon rupture in three. The 6- and 12-month primary patency rates were 46.2% and 24.1%, respectively, and the mean patency rate was 8.5 months. The 1-, 2-and 3-year accumulative patency rates were 59.8%, 47.5% and 35.7%, respectively, and the mean patency rate was 23.5 months. Other than in the history of central catheter insertion, there were no statistically significant differences in patency rates (p=0.0128). In hemodialysis patients with a central venous stricture, percutaneous angioplasty is a safe and useful procedure, but to maintain long-term central venous patency, repeated interventions are required

  3. Central Venous Disease in Hemodialysis Patients: An Update

    Energy Technology Data Exchange (ETDEWEB)

    Modabber, Milad, E-mail: mmodabber@gmail.com [McMaster University, Michael G. DeGroote School of Medicine (Canada); Kundu, Sanjoy [Scarborough Hospital and Scarborough Vascular Ultrasound, The Vein Institute of Toronto (Canada)

    2013-08-01

    Central venous occlusive disease (CVD) is a common concern among the hemodialysis patient population, with the potential to cause significant morbidity. Endovascular management of CVD, comprising percutaneous balloon angioplasty and bare-metal stenting, has been established as a safe alternative to open surgical treatment. However, these available treatments have poor long-term patency, requiring close surveillance and multiple repeat interventions. Recently, covered stents have been proposed and their efficacy assessed for the treatment of recalcitrant central venous stenosis and obstruction. Moreover, newly proposed algorithms for the surgical management of CVD warrant consideration. Here, we seek to provide an updated review of the current literature on the various treatment modalities for CVD.

  4. Pinch-off syndrome: transection of implantable central venous access device

    OpenAIRE

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-01-01

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take che...

  5. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest......Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position...

  6. [The influence of joining central venous catheter and pressure transducer with T-junctions on central venous pressure].

    Science.gov (United States)

    Cheng, Xiuling; Yang, Wanjie; An, Youzhong; Teng, Hongyun; Zhang, Rumei; Wang, Yumei; Gao, Hailing; Hua, Ning; Song, Yan

    2015-08-01

    To investigate the influence of the number of T-junctions between central venous catheter and pressure transducer on measurement of central venous pressure ( CVP ) in patients. A prospective controlled study was conducted. The patients with CVP monitoring in Department of Critical Care Medicine of the Fifth Center Hospital in Tianjin from February to October in 2014 were enrolled. The patients were divided into three groups according to the number of T-junction between central venous catheter and pressure transducer: without T-junction control group and 1, 2, 3 T-junctions groups. In each patient, corresponding CVP values with different number of T-junctions placed between the central venous catheter and pressure sensors were determined within a certain period, and a square-wave graphic was obtained and preserved on the monitor. The own frequency ( fn ) and the attenuation coefficient ( D ) of the system of pressure measurement were calculated after measurement of the shock wave following a square-wave to obtain the distance between two vibrations and the amplitude of the shock wave. The difference in CVP, fn and D were compared among the groups. A total of 20 cases were enrolled, and 150 groups of data were collected. (1) With the increase in the number of T-junction, CVP showed a tendency of gradual reduction. The CVP of the groups of control and 1, 2, 3 T-junctions was ( 7.00±1.60 ), ( 7.00±3.00 ), ( 5.00±2.00 ), and ( 4.00±1.00 ) mmHg ( 1 mmHg = 0.133 kPa ), respectively. The CVP of 3 T-junctions group was significantly lower than that of the control group ( F = 9.333, P = 0.015 ). (2) With an increase in the number of T-junction, fn showed a tendency of gradual increase. The fn of groups control and 1, 2, 3 T-junctions was ( 12.30±0.79 ), ( 16.00±0.91 ), ( 18.10±1.75 ), ( 20.90±2.69 ) Hz, respectively. The fn of 1, 2, 3 T-junctions group was significantly higher than that of the control group ( F1 = 45.962, F2 = 45.414, F3 = 46.830, all P = 0

  7. Central venous catheterization: comparison between interventional radiological procedure and blind surgical reocedure

    International Nuclear Information System (INIS)

    Song, Won Gyu; Jin, Gong Yong; Han, Young Min; Yu, He Chul

    2002-01-01

    To determine the usefulness and safety of radiological placement of a central venous catheter by prospectively comparing the results of interventional radiology and blind surgery. For placement of a central venous catheter, the blind surgical method was used in 78 cases (77 patients), and the interventional radiological method in 56 cases (54 patients). The male to female ratio was 66:68, and the patients' mean age was 48 (range, 18-80) years. A tunneled central venous catheter was used in 74 cases, and a chemoport in 60. We evaluated the success and duration of the procedures, the number of punctures required, and ensuing complications, comparing the results of the two methods. The success rates of the interventional radiological and the blind surgical procedure were 100% and 94.8%, respectively. The duration of central catheterization was 3-395 (mean, 120) day, that of chemoport was 160.9 days, and that of tunneled central venous catheter was 95.1 days. The mean number of punctures of the subclavian vein was 1.2 of interventional radiology, and 2.1 for blind surgery. The mean duration of the interventional radiology and the blind surgical procedure was, respectively, 30 and 40 minutes. The postprocedure complication rate was 27.6% (37 cases). Early complications occurred in nine cases (6.7%): where interventional radiology was used, there was one case of hematoma, and blind surgery gave rise to hematoma (n=2), pneumothorax (n=2), and early deviation of the catheter (n=4). Late complications occurred in 32 cases (23.9%). Interventional radiology involved infection (n=4), venous thrombosis (n=1), catheter displacement (n=2) and catheter obstruction (n=5), while the blind surgical procedure gave rise to infection (n=5), venous thrombosis (n=3), catheter displacement (n=4) and catheter obstruction (n=8). The success rate of interventional radiological placement of a central venous catheter was high and the complication rate was low. In comparison with the blind

  8. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    International Nuclear Information System (INIS)

    Grabbe, E.; Guthoff, A.; Hamburg Univ.

    1981-01-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations. (orig.) [de

  9. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, E; Guthoff, A

    1981-02-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations.

  10. Central venous catheter-related bloodstream infections in cancer patients

    International Nuclear Information System (INIS)

    Butt, T.; Afzal, R.K.; Ahmad, R.N.; Hussain, I.; Anwar, M.

    2004-01-01

    Objective: To determine the frequency of central venous catheter-related bloodstream infections (CR-BSI) in cancer patients and the antimicrobial susceptibility pattern of the isolates. Subjects and Methods: Cancer patients requiring short or long-term central venous catheterization at the time of admission or thereafter were included. Catheter tips on removal were cultured quantitatively; specimens of blood and pus were cultured qualitatively. Isolates were identified and antimicrobial susceptibility testing was performed by standard techniques. Results: Eighty-nine patients were included in the study. The frequency of CR-BSI was 17%. Out of the 19 organisms isolated, 10 (53%) were Gram-positive cocci, 8 (42%) were Gram-negative rods and 1 (5%) was a fungus. Coagulase negative staphylococci (27%) were the predominant pathogens. Among the staphylococci, 46% of the isolates were methicillin-resistant. All Gram-positive isolates were susceptive to glycopeptides. Gram-negative rods were resistant to most of the commonly used antimicrobial groups. Conclusion: Central venous catheter is an important source of bloodstream infections in cancer patients. Most of the infections are caused by Gram-positive cocci. Rigorous infection control measures and continuous surveillance is required to curb the frequency of these infections. (author)

  11. Is there a link between the structural impact of thoracic outlet and the development of central venous stenosis?

    Science.gov (United States)

    Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji

    2013-01-01

    Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Streitparth, Florian; Gebauer, Bernhard; Benter, Thomas

    2010-01-01

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.

  13. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  14. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    Science.gov (United States)

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  15. Reduction in central venous pressure enhances erythropoietin synthesis

    DEFF Research Database (Denmark)

    Montero, D.; Rauber, S.; Gøtze, Jens Peter

    2016-01-01

    AIMS: Erythropoiesis is a tightly controlled biological event, but its regulation under non-hypoxic conditions, however, remains unresolved. We examined whether acute changes in central venous blood pressure (CVP) elicited by whole-body tilting affect erythropoietin (EPO) concentration according...

  16. Systemic treatments for the prevention of venous thrombo-embolic events in paediatric cancer patients with tunnelled central venous catheters

    NARCIS (Netherlands)

    Schoot, Reineke A.; Kremer, Leontien C. M.; van de Wetering, Marianne D.; van Ommen, Cornelia H.

    2013-01-01

    Venous thrombo-embolic events (VTEs) occur in 2.2% to 14% of paediatric cancer patients and cause significant morbidity and mortality. The malignant disease itself, the cancer treatment and the presence of central venous catheters (CVCs) increase the risk of VTE. The primary objective of this review

  17. Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

    Science.gov (United States)

    Ainsworth, S B; Clerihew, L; McGuire, W

    2007-07-18

    Parenteral nutrition for neonates may be delivered via a short peripheral cannula or a central venous catheter. The latter may either be inserted via the umbilicus or percutaneously. Because of the complications associated with umbilical venous catheter use, many neonatal units prefer to use percutaneously inserted catheters following the initial stabilisation period. The method of parenteral nutrition delivery may affect nutrient input and consequently growth and development. Although potentially more difficult to place, percutaneous central venous catheters may be more stable than peripheral cannulae, and need less frequent replacement. These delivery methods may also be associated with different risks of adverse events, including acquired systemic infection and extravasation injury. To determine the effect of infusion via a percutaneous central venous catheter versus a peripheral cannula on nutrient input, growth and development, and complications including systemic infection, or extravasation injuries in newborn infants who require parenteral nutrition. The standard search strategy of the Cochrane Neonatal Review Group was used. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1, 2007), MEDLINE (1966 - February 2007), EMBASE (1980 - February 2007), conference proceedings, and previous reviews. Randomised controlled trials that compared the effect of delivering parenteral nutrition via a percutaneous central venous catheter versus a peripheral cannulae in neonates. Data were extracted the data using the standard methods of the Cochrane Neonatal Review Group, with separate evaluation of trial quality and data extraction by each author, and synthesis of data using relative risk, risk difference and mean difference. Four trials eligible for inclusion were found. These trials recruited a total of 368 infants and reported a number of different outcomes. One study showed that the use of a percutaneous

  18. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  19. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  20. Serious Complication of Central Venous Catheterization Due to Hemothorax: Hemothorax

    Directory of Open Access Journals (Sweden)

    Ümmügülsüm Gaygısız

    2017-12-01

    Full Text Available Central venous catheterization may cause life-threatening complications including pneumothorax and hemothorax. We report a case of multiple trauma complicated with an incidence of hemothorax due to a misplaced central venous catheter. Firstly, the tip of the guide-wire was ruptured in subcutaneous tissue and, secondly, the catheter came out of the vessel and caused hemothorax. During left subclavian catheterization, in this 47-years-old male patient, we could not advance the guide wire forward easily in the first attempt and tried to draw it back. In the second attempt, we inserted a new catheter without any difficulty. The blood gas analyses through the catheter for verification of location revealed its venous nature. After the catheterization, 500 mL hemorrhagic fluid was drained through the ipsilateral chest tube. Control chest X-ray showed that the catheter was in the left hemithorax and a piece of the guide wire was present below the left clavicle. Thorax computerized tomography showed that the catheter entered the thoracic cavity and extended to the paramediastinal region. An emergency surgery was performed to remove the piece of the guide wire and the catheter extending out of the vessel. A common method to check the intravenous insertion of a central catheter into a vein is to verify that the easily drawn blood has the nature of venous blood. This method, however, does not exclude the extravascular placement of the catheter in the presence of ipsilateral hemothorax.

  1. Reduction mammoplasty as a treatment for symptomatic central venous stenosis

    Directory of Open Access Journals (Sweden)

    Denise Seok Fun Fok

    2018-03-01

    Full Text Available Central venous stenosis is a rare cause of unilateral breast edema occurring in hemodialysis patients that needs to be differentiated from other differential diagnoses, including, but not limited to, inflammatory breast carcinoma, mastitis, lymphedema, and congestive heart failure. All reports of similar cases in the available literature have described improvement or resolution of the edema after treatment. Herein, we report and discuss the pathophysiology of breast edema formation in a patient who presented with massive left-sided breast edema 7 years after being diagnosed with central venous stenosis. Medical and minimally invasive therapy had not been successful, so she underwent reduction mammoplasty to relieve the symptoms.

  2. Pinch-off syndrome: transection of implantable central venous access device.

    Science.gov (United States)

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-11-30

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.

  3. In the absence of a central venous catheter, risk of venous thromboembolism is low in critically injured children, adolescents, and young adults: evidence from the National Trauma Data Bank.

    Science.gov (United States)

    O'Brien, Sarah H; Candrilli, Sean D

    2011-05-01

    To describe the incidence and risk factors of venous thromboembolism in a large sample of critical care pediatric, adolescent, and young adult trauma patients. The National Trauma Data Bank-the largest and most complete aggregation of trauma registry data in the United States. Seven hundred eighty-four level I to level IV trauma centers. Patients ≤ 21 yrs of age who spent at least 1 day in a critical care unit during a trauma admission between 2001 and 2005. To characterize differences between patients with and without venous thromboembolism, we extracted variables regarding patient demographics, injury pattern and severity, procedures, total length of stay, and intensive care unit and ventilator days. Odds ratios for predictors of venous thromboembolism were estimated with a logistic regression model. Among the 135,032 critical care patients analyzed, venous thromboembolism was uncommon (6 per 1,000 discharges). Placement of a central venous catheter was a significant predictor of venous thromboembolism (odds ratio = 2.24; p central venous catheter were of even greater magnitude, particularly in adolescents and young adults. The risk of venous thromboembolism in critical care patients without a central venous catheter was central venous access.

  4. Human cerebral venous outflow pathway depends on posture and central venous pressure

    Science.gov (United States)

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  5. Central venous recanalization in patients with short gut syndrome: restoration of candidacy for intestinal and multivisceral transplantation.

    Science.gov (United States)

    Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem

    2005-09-01

    To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.

  6. Bilateral Pneumothoraces Following Central Venous Cannulation

    OpenAIRE

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right ...

  7. Laser Recanalization of Central Venous Occlusion to Salvage a Threatened Arteriovenous Fistula.

    Science.gov (United States)

    Rambhia, Sagar; Janko, Matthew; Hacker, Robert I

    2018-07-01

    Central venous occlusion is conventionally managed with balloon angioplasty, stent extension, or sharp recanalization. Here, we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained 2 years postintervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  9. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  10. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  11. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    Science.gov (United States)

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  12. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  13. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    Science.gov (United States)

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  14. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  15. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  16. Predictors of Venous Thromboembolic Events Associated with Central Venous Port Insertion in Cancer Patients

    Directory of Open Access Journals (Sweden)

    Christine Hohl Moinat

    2014-01-01

    Full Text Available Insertion of central venous port (CVP catheter in the cancer population is associated with increased incidence of venous thromboembolic events (VTE. However, trials have shown limited benefit of antithrombotic treatment to prevent catheter-related venous thrombosis. This prospective observational cohort study was designed to assess the incidence of VTE closely related to CVP implantation in patients with cancer and undergoing chemotherapy, and to identify a high risk subgroup of patients. Between February 2006 and December 2011, 1097 consecutive cancer patients with first CVP implantation were included. Catheter-related VTE were defined as deep venous thrombosis in the arm, with or without pulmonary embolism (PE, or isolated PE. The incidence of CVP-associated VTE was 5.9% (IC95 4.4–7.3% at 3 months, and 11.3% (IC95 9.4–13.2% at 12 months. The incidence of any VTE was 7.6% (IC95 6.0–9.3% at 3 months, and 15.3% (IC95 13.1–17.6% at 12 months. High Khorana risk score and lung cancer were significant predictors of 3 month VTE. In conclusion, this large cohort study of patients with first CVP catheter implantation confirms the high incidence of VTE associated with the CVP implantation and allow identifying high risk patients who may benefit from thromboprophylaxis.

  17. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  18. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  19. Transposition of cephalic vein to rescue hemodialysis access arteriovenous fistula and treat symptomatic central venous obstruction

    Directory of Open Access Journals (Sweden)

    Felipe Jose Skupien

    2014-03-01

    Full Text Available It is known that stenosis or central venous obstruction affects 20 to 50% of patients who undergo placement of catheters in central veins. For patients who are given hemodialysis via upper limbs, this problem causes debilitating symptoms and increases the risk of loss of hemodialysis access. We report an atypical case of treatment of a dialysis patient with multiple comorbidities, severe swelling and pain in the right upper limb (RUL, few alternative sites for hemodialysis vascular access, a functioning brachiobasilic fistula in the RUL and severe venous hypertension in the same limb, secondary to central vein occlusion of the internal jugular vein and right brachiocephalic trunk. The alternative surgical treatment chosen was to transpose the RUL cephalic vein, forming a venous necklace at the anterior cervical region, bypassing the site of venous occlusion. In order to achieve this, we dissected the cephalic vein in the right arm to its junction with the axillary vein, devalved the cephalic vein and anastomosed it to the contralateral external jugular vein, providing venous drainage to the RUL, alleviating symptoms of venous hypertension and preserving function of the brachiobasilic fistula.

  20. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  1. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  2. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz [Prince Sultan Military Medical City (PSMMC), Division of Endovascular Interventional Radiology, Department of Medical Imaging (Saudi Arabia); Ahmed, Dildar; Aslam, Naveed [Prince Sultan Military Medical City (PSMMC), Department of Nephrology (Saudi Arabia)

    2016-06-15

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  3. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    International Nuclear Information System (INIS)

    Arabi, Mohammad; Ahmed, Ishtiaq; Mat’hami, Abdulaziz; Ahmed, Dildar; Aslam, Naveed

    2016-01-01

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  4. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    Science.gov (United States)

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  6. Using central venous catheter for suprapubic catheterization in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Bilehjani E

    2017-01-01

    Full Text Available Eissa Bilehjani,1 Solmaz Fakhari2 1Department of Cardiovascular Anesthesia, Tabriz University of Medical Sciences, Madani Heart Hospital, 2Department of Anesthesiology, Tabriz University of Medical Sciences, Madani Heart Hospital, Tabriz, Iran Abstract: Suprapubic catheterization is an alternative method for urinary drainage that is used when transurethral catheterization fails. Traditionally, inserted large-bore suprapubic catheters may cause fatal complications. During the past decade, we used a small central venous catheter (CVC suprapubicly in 16 male patients for the purpose of urinary drainage, when transurethral catheterization failed. The procedure is performed in no more than 10 minutes. Success rate was 100% and this approach did not lead to any complications. In conclusion, placing a CVC for suprapubic drainage is a safe method with a high success rate and we recommend it in patients with failed transurethral catheterization after a few attempts (2–3 attempts. Keywords: suprapubic catheterization complication, urethral catheterization, central venous catheter, Seldinger’s technique, cardiac surgery

  7. Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis

    International Nuclear Information System (INIS)

    Ni, Nina; Mojibian, Hamid; Pollak, Jeffrey; Tal, Michael

    2011-01-01

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ 2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P 2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P 2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.

  8. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    Science.gov (United States)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  9. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  10. Renal vein to renal collecting system fistula: An extreme complication from central venous thrombosis secondary to indwelling catheter

    Directory of Open Access Journals (Sweden)

    Aditya Safaya

    2018-04-01

    Full Text Available Central venous catheters are routinely used for resuscitation, chemotherapy and nutrition but are not without risk. Central lines are the most common extrinsic cause of venous thrombosis in neonates and infants. We present an ex-36 week 1800g infant baby girl recovering after a staged repair of gastroschisis with ileostomy and mucous fistula formation. The patient was receiving parenteral nutrition through an indwelling saphenous vein tunneled catheter, with its tip in the inferior vena cava. The patient developed polyuria, with a characteristic odor of the parenteral nutrition and a urine analysis showed glucose and triglyceride levels consistent with the composition of the parenteral nutrition fluid. A fluoroscopic cysto-urogram and an inferior vena-cavogram showed a catheter-associated inferior vena cava thrombosis leading to backpressure changes, diverting all intravenous contrast into the right renal vein and to renal collecting system, thus elucidating the route of the parenteral nutrition fluid reaching the bladder. Our case represents an extreme case of complicated central venous thrombosis. We emphasize the importance of practicing a high index of suspicion for thrombotic complications in severely ill neonates with central venous access. An early diagnosis and aggressive management may prevent progression of the disease towards an overwhelming complication. Keywords: Central venous catheterization complications, Renal vein-collecting system connection, Renal vein- collecting system fistula

  11. Interventional radiology in the provision and maintenance of long-term central venous access

    International Nuclear Information System (INIS)

    Lyon, S.M.; Given, M.; Marshall, N.L.

    2008-01-01

    Establishing and maintaining venous access forms an increasing proportion of the workload in interventional radiology. Several patient groups require medium-term to long-term venous catheters for a variety of purposes, including chemotherapy, long-term antimicrobials, parenteral nutrition, short-term access for haemodialysis or exhausted haemodialysis. Often, these catheters are required for treatment and frequent blood testing, which can quickly exhaust the peripheral veins. Venous access devices include implantable catheters (ports), tunnelled catheters and peripherally inserted central catheters, which have different functions, advantages and limitations. Imaging-guided placement is the preferred method of insertion in many institutions because of higher success rates and radiologists are well suited to address catheter complications.

  12. Pain and efficacy of local anesthetics for central venous access

    Directory of Open Access Journals (Sweden)

    William C Culp Jr

    2008-11-01

    Full Text Available William C Culp Jr1, Mohammed Yousaf2, Benjamin Lowry1, Timothy C McCowan3, William C Culp21Division of Cardiothoracic Anesthesiology, Scott and White Hospital, The Texas A&M University College of Medicine, Temple, TX, USA; 2Division of Interventional Radiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA; 3Department of Radiology, University of Mississippi Medical Center, Jackson, MS, USAPurpose: To compare pain during injection and efficacy of analgesia of local anesthetics during central venous line placement.Methods: Sixty-two patients were studied in a randomized, double-blinded prospective fashion. Patients received 1% lidocaine (L, buffered 1% lidocaine (LB, or 2% chloroprocaine (CP injected around the internal jugular vein for procedural analgesia for central venous access. Patients reported pain via a standard linear visual analog scale, with 0 representing no pain and 10 being the worst pain imaginable.Results: Overall patient perception of pain was better with CP and L than LB with mean scores of CP 2.4, L 2.6, LB 4.2. Pain with injection mean scores were CP 2.1, L 2.5, LB 3.2. Pain with catheter placement scores were CP 2.5, L 1.7, LB 3.4. Operator assessment of overall pain values were CP 1.9, L 2.2, LB 3.4. LB consistently scored the worst, though compared with CP, this only reached statistical significance in overall patient pain and pain at catheter insertion compared with L.Conclusion: Though chloroprocaine scored better than lidocaine in 3 of 4 parameters, this trend did not achieve statistical significance. Adding sodium bicarbonate to lidocaine isn’t justified in routine practice, nor is routine replacement of lidocaine with chloroprocaine.Keywords: local anesthesia, analgesia, central venous access, lidocaine, chloroprocaine

  13. Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.

    Science.gov (United States)

    Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun

    2015-06-01

    Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (Pcatheterization (Pcatheterization and internal jugular vein catheterization (Pvenous thrombosis history (Pvenous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.

  14. Cryopreserved recombinant tissue plasminogen activator for the restoration of occluded central venous access devices in pediatric oncology patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Al-Katheri, A.; Al-Sedairy, R.; Al-Omari, A.; Abdullah, Mohammed F.; Crankson, S.

    2002-01-01

    Thrombolytic therapy with urokinase 5000 units has been the standard therapy for restoration of thrombosed central catheters. However, with the decreased availability of urokinase, alternatives needed to be sought. The aim of the study was to determine the efficacy, bioactivity, dwell time and cost of cryopreserved recombinant tissue plasminogen activator (rTPA) in the restoration of occluded central venous access devices. For children 10kg, a dose of 1 mg was used. The dwell time was 1-2 hours. Of the 40 courses of rTPA, 39 fully restored central venous line patency (97%). Successful courses were instilled for an average of 1 hour. Cryopreserved rTPA appears to be safe and effective in the dose used to restore the patency of occluded central venous access devices in pediatric oncology patients. (author)

  15. Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial.

    Science.gov (United States)

    Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo

    2017-08-01

    We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.

  16. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  17. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients.

    Science.gov (United States)

    Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien

    2015-11-01

    Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p risk of infection than for patients in a nonadjuvant setting (p ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.

  18. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  19. Lights, camera and action in the implementation of central venous catheter dressing.

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    To develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. This is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. The items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. The educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  20. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  1. [Complications associated to central venous catheters in hematology patients].

    Science.gov (United States)

    García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia

    2015-01-01

    To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  2. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  3. Central venous access through the external jugular vein in children submitted to bone marrow transplantation

    Directory of Open Access Journals (Sweden)

    José Luiz de Godoy

    2005-01-01

    Full Text Available Establishment of long-term central venous access is a sine qua non step for bone marrow transplantation in children. Most frequently, long-term central venous access has been obtained via blind percutaneous cannulation of subclavian and internal jugular veins or via internal jugular vein cutdown. In order to avoid some potential minor and major complications associated with the subclavian or internal jugular approaches, the authors describe an easy, simple and safe method for central venous access through an external jugular vein cutdown that should be of interest to readers involved in the field of bone marrow transplantation. It should be also considered for children as well as adults needing central venous access via an external catheter - or totally implantable port - for reasons other than bone marrow transplantation, such as total parenteral nutrition and administration of chemotherapeutic agents.O estabelecimento de um acesso venoso central de longa duração é uma condição sine qua non para realizar o transplante de medula óssea em crianças. Com frequência, este acesso tem sido obtido através da punção percutânea das veias subclávia e jugular interna ou via dissecção da jugular interna. Com o objetivo de evitar algumas complicações maiores e menores associadas com a subclávia e a jugular interna, os autores descrevem um método simples, fácil e seguro para o acesso venoso central através de dissecção da veia jugular externa. Este método deveria ser de interesse dos leitores envolvidos com o transplante de medula óssea e ser considerado também para crianças e/ou adultos que necessitem de cateter venoso central de longa permanência (externo ou totalmente implantável devido a outras razões, como a nutrição parenteral ou a administração de agentes quimioterápicos.

  4. Results of surgery in symptomatic non-hydrocephalic pineal cysts: role of magnetic resonance imaging biomarkers indicative of central venous hypertension.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2017-02-01

    We have previously proposed that pineal cysts (PCs) may result in crowding of the pineal recess, causing symptoms due to compression of the internal cerebral veins and central venous hypertension. In the present study, we compared clinical outcome of different treatment modalities in symptomatic individuals with non-hydrocephalic PCs. The study included all patients managed surgically for non-hydrocephalic PCs in our Department of Neurosurgery over a 10-year period. We applied a questionnaire to determine occurrence of symptoms before and after surgery, which allowed the use of a grading scale for symptom severity. Magnetic resonance imaging (MRI) biomarkers indicative of central venous hypertension were assessed before and after surgery. Relief of symptoms after surgery was most efficiently obtained by complete microsurgical cyst removal [n = 15; no (0/15), some (1/15) or marked (14/15) improvement], and to a lesser extent by microsurgical cyst fenestration [n = 6; no (2/6), some (4/6) or marked (0/6) improvement]. Shunt surgery was not successful [n = 6; no (5/6), some (1/6) or marked (0/6) improvement]. In all patients, the proposed MRI biomarkers gave evidence of central venous hypertension (PC grades 2-4). Microsurgical cyst removal provided marked symptom relief in symptomatic individuals with non-hydrocephalic PCs and MRI biomarkers of central venous hypertension. The hypothesis that PC-induced crowding of the pineal recess may compromise venous run-off and induce a central venous hypertension syndrome deserves further study.

  5. Preventing central venous catheter-related infection in a surgical intensive-care unit

    NARCIS (Netherlands)

    Bijma, R; Girbes, AR; Kleijer, DJ; Zwaveling, JH

    The cumulative effect of five measures (introduction of hand disinfection with alcohol, a new type of dressing, a one-bag system for parenteral nutrition, a new intravenous connection device, and surveillance by an infection control practitioner) on central venous catheter colonization and

  6. An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Engin OZAKIN

    2014-06-01

    Full Text Available SUMMARY: Objectives: In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days following the insertion of central venous catheter under ultrasound guidance in the emergency department. Methods: For this study, patients who presented to the emergency department over a period of eight months with an urgent need for central catheter were examined prospectively. Age, gender, and accompanying diseases of patients as well as the type, time, duration, and indication of the venous access were recorded. Furthermore, the amount of experience of the physician was taken into consideration. Results: In the emergency department, physicians performed ultrasound-guided central venous catheter insertion for 74 patients (40 men and 34 women. For access, internal jugular vein was used in 65 (87.8% patients, and femoral vein was used in 9 (12.2% patients. The reason for access was urgent dialysis need in 55 (74.3%, CVP measurement in 3 (4.1%, fluid support due to severe hypovolemia in 6 (8.1%, and difficulty of peripheral venous access in 10 (13.5% patients. None of the patients developed complications in the process of or after the insertion. Patients did not have infections related to the catheter in 15 days following the insertion. Conclusions: Central venous access is frequently required in emergency departments. The risk of complication is little if any in ultrasonographyguided access carried out under appropriate conditions. ÖZET: Amaç: Acil servislerde acil tıp hekimlerince santral damar yolu işlemi sık uygulanır. Periferik damar yolu açılamadığı hallerde, diyaliz, acil sıvı ihtiyacı veya santral venöz basınç

  7. Lights, camera and action in the implementation of central venous catheter dressing

    Directory of Open Access Journals (Sweden)

    Maria Verônica Ferrareze Ferreira

    2015-12-01

    Full Text Available Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  8. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  9. Repositioning and Leaving In Situ the Central Venous Catheter During Percutaneous Treatment of Associated Superior Vena Cava Syndrome: A Report of Eight Cases

    International Nuclear Information System (INIS)

    Stockx, Luc; Raat, Henricus; Donck, Jan; Wilms, Guy; Marchal, Guy

    1999-01-01

    Purpose: To describe a combined procedure of repositioning and leaving in situ a central venous catheter followed by immediate percutaneous treatment of associated superior vena cava syndrome (SVCS). Methods: Eight patients are presented who have central venous catheter-associated SVCS (n = 6 Hickman catheters, n = 2 Port-a-cath) caused by central vein stenosis (n = 4) or concomitant thrombosis (n = 4). With the use of a vascular snare introduced via the transcubital or transjugular approach, the tip of the central venous catheter could be engaged, and repositioned after deployment of a stent in the innominate or superior vena cava. Results: In all patients it was technically feasible to reposition the central venous catheter and treat the SVCS at the same time. In one patient flipping of the Hickman catheter in its original position provoked dislocation of the released Palmaz stent, which could be positioned in the right common iliac vein. Conclusion: Repositioning of a central venous catheter just before and after stent deployment in SVCS is technically feasible and a better alternative than preprocedural removal of the vascular access

  10. Central venous catheterization training: current perspectives on the role of simulation

    Directory of Open Access Journals (Sweden)

    Soffler MI

    2018-05-01

    Full Text Available Morgan I Soffler,1,2 Margaret M Hayes,2–4 C Christopher Smith3–5 1Harvard Combined Pulmonary and Critical Care Fellowship at Massachusetts General Hospital and Beth Israel Deaconess Medical Center, Boston, MA, USA; 2Division of Pulmonary, Critical Care, and Sleep Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA; 3Internal Medicine Residency Program, Beth Israel Deaconess Medical Center, Boston, MA, USA; 4Shapiro Institute for Education and Research, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA; 5Division of General Internal Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA Abstract: Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. Keywords: simulation, central venous catheterization, assessment, competency, central line insertion

  11. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  12. Extravasation of parenteral alimentation fluid into the renal pelvis--a complication of central venous catheter in a neonate.

    Science.gov (United States)

    Nadroo, A M; al-Sowailem, A M

    2001-01-01

    Many complications of central venous catheters, which include perforation of the vessel walls and extravasation of the infusate into pericardial, pleural, and peritoneal cavities, have been reported. We report an infant with a central venous catheter in inferior vena cava who experienced extravasation of parenteral alimentation fluid into the right renal pelvis secondary to perforation of the renal vein. To our knowledge, this rare complication has not been reported earlier.

  13. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  14. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  15. [Doctor-nurse delegation of the insertion of central venous lines].

    Science.gov (United States)

    Cellupica, Mary

    2015-01-01

    The Léon Bérard Cancer Centre treats the disease in all its complexity with numerous disciplines such as surgery, medicine, radiotherapy, palliative care, home care, etc. The insertion of a central venous line is an essential part of cancer care and the nursing profession. It enables patients to have their treatment administered in the best possible conditions and without risk. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  17. Spontaneous migration of central venous catheter tip following extubation

    Directory of Open Access Journals (Sweden)

    Balaji Prabaharan

    2014-01-01

    Full Text Available Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

  18. Simulation training for pediatric residents on central venous catheter placement: a pilot study.

    Science.gov (United States)

    Thomas, Scott M; Burch, Wesley; Kuehnle, Sarah E; Flood, Robert G; Scalzo, Anthony J; Gerard, James M

    2013-11-01

    To assess the effect of simulation training on pediatric residents' acquisition and retention of central venous catheter insertion skills. A secondary objective was to assess the effect of simulation training on self-confidence to perform the procedure. Prospective observational pilot study. Single university clinical simulation center. Pediatric residents, postgraduate years 1-3. Residents participated in a 60- to 90-minute ultrasound-guided central venous catheter simulation training session. Video recordings of residents performing simulated femoral central venous catheter insertions were made before (baseline), after, and at 3-month following training. Three blinded expert raters independently scored the performances using a 24-item checklist and 100-mm global rating scale. At each time point, residents rated their confidence to perform the procedure on a 100-mm scale. Twenty-six residents completed the study. Compared with baseline, immediately following training, median checklist score (54.2% [interquartile range, 40.8-68.8%] vs 83.3% [interquartile range, 70.0-91.7%]), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 79.5 mm [interquartile range, 16.3-91.7 mm]), success rate (38.5% vs 80.8%), and self-confidence (8.0 mm [interquartile range, 3.8-19.0 mm] vs 52.0 mm [interquartile range, 43.5-66.5 mm]) all improved (p interquartile range, 40.8-68.8%] vs 54.2% [interquartile range, 45.8-80.4%], p = 0.47), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 35.5 mm [interquartile range, 5.3-77.0], p = 0.62), and success rate (38.5% vs 65.4%, p = 0.35) were similar at 3-month follow-up. Self-confidence, however, remained above baseline at 3-month follow-up (8.0 mm [interquartile range, 3.8-19.0 mm] vs 61.0 mm [interquartile range, 31.5-71.8 mm], p < 0.01). Simulation training improved pediatric residents' central venous catheter insertion procedural skills. Decay in skills was found at 3-month follow-up. This suggests that

  19. STUDY OF CENTRAL VENOUS CATHETER RELATED BLOOD STREAM INFECTIONS IN PATIENTS ON HAEMODIALYSIS

    Directory of Open Access Journals (Sweden)

    Pranjal Pankaj

    2018-01-01

    Full Text Available BACKGROUND Temporary and permanent central venous catheters are used in majority of patients of CKD when initiated on hemodialysis and mostly these catheters act as bridge before permanent AV fistula assess could be obtained. Blood stream infections related to these central venous catheters are an important cause of morbidity and mortality in these patients. Appropriate antiseptic precautions while inserting central venous catheter and early identification of catheter related blood stream infections (CRBSI are of utmost importance for reducing hospital stay, cost of therapy and mortality. MATERIALS AND METHODS A total of 50 patients of CKD were included in the study who had central venous catheter in situ (internal jugular or subclavian and developed symptoms related to blood stream infections. Blood cultures were obtained from the catheter lumen and a separate venous site 1 hour apart. All the culture sensitivity reports were obtained from department of microbiology of our institute. Inclusion Criteria- Known case of CKD patients aged more than 18yrs on hemodialysis with symptoms and signs of catheter related blood stream infections were included in the study. Exclusion Criteria- Patients with other associated comorbid infections like Koch’s, urinary tract infection or others mimicking symptoms of CRBSI. RESULTS The cultures were found positive in 38 patients (76% while in rest 24% cases positive cultures could not be obtained. Out of culture positive patients 52.63% cases were found to have gram positive infections while 44.74% had gram negative infections. In 2.63% patients, fungus was isolated to be the causative organism. Among the gram positive organisms 50% had CoNS, 30% had MSSA and 20% had MRSA infections. Among the gram negative group, 47.06% had klebsiella, 23.53% had acinetobacter, 17.65% had E.coli and 11.76% had pseudomonas as the causative organisms. Mortality was observed in 14% patients out of which 28.57% were culture

  20. Lights, camera and action in the implementation of central venous catheter dressing1

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters. PMID:26626011

  1. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    Science.gov (United States)

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  2. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  3. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2015-11-01

    Conclusion: Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings.

  4. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    Science.gov (United States)

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Bilateral Pneumothoraces Following Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    F. Pazos

    2009-01-01

    Full Text Available We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax.

  6. Bilateral Pneumothoraces Following Central Venous Cannulation

    Science.gov (United States)

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  7. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  8. Cardiac tamponade in an infant during contrast infusion through central venous catheter for chest computed tomography; Tamponamento cardiaco durante infusao de contraste em acesso venoso central para realizacao de tomografia computadorizada do torax em lactente

    Energy Technology Data Exchange (ETDEWEB)

    Daud, Danilo Felix; Campos, Marcos Menezes Freitas de; Fleury Neto, Augusto de Padua [Hospital Geral de Palmas, TO (Brazil)

    2013-11-15

    Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein. (author)

  9. Comparison of three types of central venous catheters in patients with malignant tumor receiving chemotherapy

    Directory of Open Access Journals (Sweden)

    Fang S

    2017-07-01

    Full Text Available Shirong Fang,1 Jinhong Yang,2 Lei Song,3 Yan Jiang,1 Yuxiu Liu4 1Department of Anesthesiology, 2Department of Oncology, Weifang People’s Hospital, Weifang, 3Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao, 4Nursing College, Weifang Medical University, Weifang, People’s Republic of China Background: Central venous catheters (CVCs have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs, and external non-tunneled central venous catheters (NTCs.Methods: A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal.Results: There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion: Although port catheterization costs more and needs professional medical staff and strict operational

  10. Multicenter study in monitoring central venous catheters complications in hematologic patiennts

    Directory of Open Access Journals (Sweden)

    Carmen García Gabás

    2013-05-01

    Full Text Available Most hematological patients suffer a significant venous damage related to different administrated intravenous therapy, being necessary to place central venous catheters (CVC. CVC is associated with various complications. The most common catheter-related complications are occlusion and infection. To avoid such of them, the development of protocols for insertion and care are needed, as well as recording and following up complications. To this end, we propose a cross-sectional carried out during 13 months whose main goal is to know the incidence of CVC- related complications (mainly occlusion and infection in hematological patients.Population included all the =14 ages patients admitted to different hematological units at Ramon y Cajal and Gregorio Marañón hospitals in Madrid and who signed informed consent. Socio-demographic, clinical characteristics and complications were entered into a log which included a pursuit of care protocol.

  11. Arterial and venous revascularization with bifurcation of a single central artery: a reliable strategy for Tamai Zone I replantation.

    Science.gov (United States)

    Hsu, Chung-Chen; Lin, Yu-Te; Moran, Steven L; Lin, Cheng-Hung; Wei, Fu-Chan; Lin, Chih-Hung

    2010-12-01

    Replantation of the distal phalanx and pulp can be performed to improve finger function and finger aesthetics; however, establishing adequate venous drainage is a challenge. Slattery et al. reported microsurgical reattachment of a partial distal phalanx with the use of a bifurcated terminal digital artery. The bifurcation was divided into two pedicles, one of which was used for venous drainage. In this article, the authors report their experience with a similar technique and propose a new algorithm for distal finger replantation. From January of 2008 to February of 2009, five replantations were performed using a single central artery. The replanted levels were pulp, avulsed fingertip of the thumb, and distal phalanges. There was no volar vein, dorsal vein, or second artery available in the amputated part for standard venous drainage. Venous drainage in all cases was established by creating an anastomosis from a branch of the solitary terminal artery to a recipient vein. All digits were replanted successfully without evidence of arterial insufficiency or venous congestion. Partial necrosis was not identified postoperatively in any of the five fingers. There were no cases of wound infection. A branch of the central solitary artery may be used successfully to reestablish venous outflow in cases of distal finger tip replantation. This technique allowed for the salvage of all fingers in this study without the use of leeches or other techniques used in cases of venous insufficiency.

  12. Central venous oxygenation: when physiology explains apparent discrepancies.

    Science.gov (United States)

    Squara, Pierre

    2014-11-10

    Central venous oxygen saturation (ScvO2) >70% or mixed venous oxygen saturation (SvO2) >65% is recommended for both septic and non-septic patients. Although it is the task of experts to suggest clear and simple guidelines, there is a risk of reducing critical care to these simple recommendations. This article reviews the basic physiological and pathological features as well as the metrological issues that provide clear evidence that SvO2 and ScvO2 are adaptative variables with large inter-patient variability. This variability is exemplified in a modeled population of 1,000 standard ICU patients and in a real population of 100 patients including 15,860 measurements. In these populations, it can be seen how optimizing one to three of the four S(c)vO2 components homogenized the patients and yields a clear dependency with the fourth one. This explains the discordant results observed in large studies where cardiac output was increased up to predetermined S(c)vO2 thresholds following arterial oxygen hemoglobin saturation, total body oxygen consumption needs and hemoglobin optimization. Although a systematic S(c)vO2 goal-oriented protocol can be statistically profitable before ICU admission, appropriate intensive care mandates determination of the best compromise between S(c)vO2 and its four components, taking into account the specific constraints of each individual patient.

  13. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  14. Reverse Trendelenburg position is a safer technique for lowering central venous pressure without decreasing blood pressure than clamping of the inferior vena cava below the liver.

    Science.gov (United States)

    Yoneda, Godai; Katagiri, Satoshi; Yamamoto, Masakazu

    2015-06-01

    Bleeding remains an important intraoperative complication in patients who undergo hepatectomy. It is generally believed that a reduction in central venous pressure will decrease bleeding from the hepatic venous system. To our knowledge, however, no study has compared the effectiveness of these techniques for controlling bleeding. So we compared the effectiveness of central venous pressure control techniques, such as infrahepatic inferior vena cava clamping, changes in surgical position of the patient, and hypoventilation anesthesia, for lowering central venous pressure. The study group comprised 50 patients who underwent hepatectomy in our department from 2012 through 2013. A central venous catheter was inserted into the right internal jugular vein, and the tip was placed in the superior vena cava. A transducer was placed along the mid-axillary line of the left side of the chest. After opening the abdomen, changes in central venous pressure were measured during inferior vena cava clamping, the reverse Trendelenburg position, the Trendelenburg position, and hypoventilation anesthesia. The inclination relative to the transducer, as measured with an inclinometer, was -10 degrees for the Trendelenburg position and +10 degrees for the reverse Trendelenburg position. The tidal volume was set at 10 mL/kg during conventional anesthesia and 5 mL/kg during hypoventilation anesthesia. The mean central venous pressure was 8.0 cm H(2)O in the supine position during conventional anesthesia, 5.0 cm H(2)O during inferior vena cava clamping, 5.6 cm H(2)O during reverse Trendelenburg position, 10.6 cm H(2)O during Trendelenburg position, and 7.6 cm H(2)O during hypoventilation anesthesia. The mean central venous pressure during inferior vena cava clamping and reverse Trendelenburg position was significantly lower than that during supine position (P = 0.0017 and P = 0.0231, respectively). The mean central venous pressure during hypoventilation

  15. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    Science.gov (United States)

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  16. Radiologic placement of hemodialysis central venous catheters: a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Schemmer, D.; Sadler, D.J.; Gray, R.R.; Saliken, J.C.; So, C.B. [Foothills Hospital, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)

    2001-04-01

    Typical indications for central venous catheters (CVCs) are hemodialysis (HD), apheresis, total parenteral nutrition, analgesia, chemotherapy, long-term antibiotic therapy and cases of difficult or absent peripheral venous access. One of the largest medical services requesting CVC insertion is nephrology for HD patients. Demographics dictate that the demand for CVCs will continue to grow over the next few decades, placing striking demands on interventional radiology departments. In our centre, interventional radiologists now place nearly all percutaneously inserted HD CVCs. Radiologists provide rapid access to CVC services with significantly fewer complications than CVCs placed by other clinicians. With the demand for CVC management increasing and available operating room time decreasing, many clinicians now refer CVC insertions to radiologists. As well, clinicians who ordinarily place their own lines often refer high-risk patients, such as those who are obese or uncooperative and those with burns or coagulopathy. Our experience, derived from over 7000 CVC insertions, manipulations and removals, has allowed us to continually progress and improve our techniques, many of which are summarized here. (author)

  17. Retrospective analysis of intravertebral collateral enhancement in patients with central venous obstruction

    International Nuclear Information System (INIS)

    Simeone, F.J.; Chang, Connie Y.; Huang, Ambrose J.; Kattapuram, Susan V.; Bredella, Miriam A.; Torriani, Martin; Bennett, Debbie L.

    2016-01-01

    To compare prevalence and patterns of intravertebral collateral enhancement in patients with and without central venous obstruction (CVO). Chest CTs performed between 1/1/2000 and 12/15/2012 with reports containing terms indicating CVO were identified. All contrast enhanced CTs were examined for the presence of CVO and collateral venous pathways. If intravertebral collateral enhancement was present, the pattern was recorded as nodular, linear, or both. In 209 suspected cases of CVO, 53 (25 %) were confirmed with obstruction and 156 (75 %) were without obstruction. In patients with CVO, 47 % (25/53) demonstrated collateral venous flow through an intravertebral marrow pathway compared to 5 % (8/156) of patients without CVO (P < 0.0001). The most common level of enhancement was the upper thoracic spine, involving only the vertebral body. Nodular, linear, and combined nodular-linear enhancement patterns were seen with similar frequency. Nodular intravertebral collateral enhancement was mistaken for sclerotic metastases in 33 % (3/9) of cases. Intravertebral collateral enhancement was seen in almost half the patients with CVO and when nodular enhancement is present, it is important to differentiate between metastatic lesions and enhancement related to CVO. (orig.)

  18. Retrospective analysis of intravertebral collateral enhancement in patients with central venous obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Simeone, F.J.; Chang, Connie Y.; Huang, Ambrose J.; Kattapuram, Susan V.; Bredella, Miriam A.; Torriani, Martin [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Bennett, Debbie L. [Saint Louis University School of Medicine, Department of Radiology, Saint Louis, MO (United States)

    2016-02-15

    To compare prevalence and patterns of intravertebral collateral enhancement in patients with and without central venous obstruction (CVO). Chest CTs performed between 1/1/2000 and 12/15/2012 with reports containing terms indicating CVO were identified. All contrast enhanced CTs were examined for the presence of CVO and collateral venous pathways. If intravertebral collateral enhancement was present, the pattern was recorded as nodular, linear, or both. In 209 suspected cases of CVO, 53 (25 %) were confirmed with obstruction and 156 (75 %) were without obstruction. In patients with CVO, 47 % (25/53) demonstrated collateral venous flow through an intravertebral marrow pathway compared to 5 % (8/156) of patients without CVO (P < 0.0001). The most common level of enhancement was the upper thoracic spine, involving only the vertebral body. Nodular, linear, and combined nodular-linear enhancement patterns were seen with similar frequency. Nodular intravertebral collateral enhancement was mistaken for sclerotic metastases in 33 % (3/9) of cases. Intravertebral collateral enhancement was seen in almost half the patients with CVO and when nodular enhancement is present, it is important to differentiate between metastatic lesions and enhancement related to CVO. (orig.)

  19. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  20. When one port does not return blood: two case reports of rare causes for misplaced central venous catheters

    Directory of Open Access Journals (Sweden)

    Sandra Pereira

    2016-01-01

    Full Text Available We present two cases of misplaced central venous catheters having in common the absence of free blood return from one lumen immediately after placement. The former is a case of right hydrothorax associated with central venous catheterization with the catheter tip in intra-pleural location. In this case the distal port was never patent. In the latter case there was an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not be undervalued. In these circumstances the catheter should not be used and needs to be removed. Resumo: Apresentamos dois casos de mau posicionamento de cateter venoso central. Têm em comum a ausência do retorno sanguíneo livre em um dos lúmens imediatamente após a colocação. O primeiro é um caso de hidrotórax direito associado ao cateterismo venoso central, com a ponta do cateter em localização intrapleural. Nesse caso, a porta distal nunca esteve patente. No segundo caso houve um aumento da pressão de aspiração através da porta medial por causa da formação de alça no cateter.A ausência de fluxo livre na aspiração de um lúmen do cateter central não deve ser subestimada. Nessas circunstâncias, o cateter não deve ser usado e deve ser removido. Keywords: Central venous catheter, Hydrothorax, Looping, Malposition, Palavras-chave: Cateter venoso central, Hidrotórax, Alça, Mau posicionamento

  1. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  2. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  3. Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

    Science.gov (United States)

    Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri

    2015-11-01

    Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.

  4. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    Science.gov (United States)

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  5. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  6. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  7. Central and peripheral venous lines-associated blood stream infections in the critically ill surgical patients.

    Science.gov (United States)

    Ugas, Mohamed Ali; Cho, Hyongyu; Trilling, Gregory M; Tahir, Zainab; Raja, Humaera Farrukh; Ramadan, Sami; Jerjes, Waseem; Giannoudis, Peter V

    2012-09-04

    Critically ill surgical patients are always at increased risk of actual or potentially life-threatening health complications. Central/peripheral venous lines form a key part of their care. We review the current evidence on incidence of central and peripheral venous catheter-related bloodstream infections in critically ill surgical patients, and outline pathways for prevention and intervention. An extensive systematic electronic search was carried out on the relevant databases. Articles were considered suitable for inclusion if they investigated catheter colonisation and catheter-related bloodstream infection. Two independent reviewers engaged in selecting the appropriate articles in line with our protocol retrieved 8 articles published from 1999 to 2011. Outcomes on CVC colonisation and infections were investigated in six studies; four of which were prospective cohort studies, one prospective longitudinal study and one retrospective cohort study. Outcomes relating only to PICCs were reported in one prospective randomised trial. We identified only one study that compared CVC- and PICC-related complications in surgical intensive care units. Although our search protocol may not have yielded an exhaustive list we have identified a key deficiency in the literature, namely a paucity of studies investigating the incidence of CVC- and PICC-related bloodstream infection in exclusively critically ill surgical populations. In summary, the diverse definitions for the diagnosis of central and peripheral venous catheter-related bloodstream infections along with the vastly different sample size and extremely small PICC population size has, predictably, yielded inconsistent findings. Our current understanding is still limited; the studies we have identified do point us towards some tentative understanding that the CVC/PICC performance remains inconclusive.

  8. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2015-01-01

    Full Text Available Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforation, arrhythmias, sepsis, and pulmonary embolism. A 12-year-old female received chemotherapy for acute lymphocytic leukemia through a central venous port implanted into her right subclavian area. The patient completed chemotherapy without complications 6 months ago. Venous port was accidentally fractured during its removal. Chest radiographs of the patient revealed intracardiac catheter fragment extending from the right subclavian to the right atrium (RA and looping in the RA. The procedure was performed under ketamine and midazolam anesthesia and fluoroscopic guidance using a percutaneous femoral vein approach. A snare with triple loops (10 mm in diameter was used to successfully retrieve the catheter fragments without any complication. Percutaneous transcatheter retrieval of catheter fragments is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters and can be chosen before resorting to surgery, which has potential risks related to thoracotomy, cardiopulmonary bypass, and general anesthesia.

  9. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  10. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  12. Central venous catheter (CVC) removal for patients of all ages with candidaemia

    DEFF Research Database (Denmark)

    Janum, Susanne; Afshari, Arash

    2016-01-01

    BACKGROUND: Candida bloodstream infections most often affect those already suffering serious, potentially life-threatening conditions and often cause significant morbidity and mortality. Most affected persons have a central venous catheter (CVC) in place. The best CVC management in these cases has......, GRADE - Grades of Recommendation, Assessment, Development and Evaluation Working Group). AUTHORS' CONCLUSIONS: Despite indications from observational studies in favour of early catheter removal, we found no eligible RCTs or quasi-RCTs to support these practices and therefore could draw no firm...

  13. Acesso venoso central guiado por ultrassom: qual a evidência? Ultrasound-guided central venous catheterization: what is the evidence?

    Directory of Open Access Journals (Sweden)

    Felippe Leopoldo Dexheimer Neto

    2011-06-01

    Full Text Available Recentemente, órgãos internacionais de qualidade em saúde passaram a recomendar o uso de orientação ultrassonográfica para punções venosas centrais. O objetivo deste artigo foi revisar as evidências fundamentando tais recomendações. Foi revisada a literatura no MEDLINE, PubMed e SCIELO com os seguintes termos (MeSH: acesso venoso central, ultrassom e adultos. A pesquisa realizada em 24/09/2010, com seleção de metanálises, ensaios clínicos randomizados e revisões, encontrou 291 artigos. Os 21 artigos mais importantes foram utilizados para a confecção desta revisão. A veia jugular interna é o local mais estudado para punções guiadas por ultrassonografia, com metanálises demonstrando menor risco relativo de falha e de complicações. Além disso, o maior ensaio clínico randomizado disponível também demonstrou redução na incidência de infecções de corrente sanguínea associadas aos cateteres venosos centrais. Poucos estudos existem com relação à punção da veia subclávia, porém o uso do ultrassom mostrou-se benéfico em duas metanálises (mas com um número pouco expressivo de pacientes. Quanto ao sítio venoso femoral, há apenas um ensaio clínico randomizado (20 pacientes, o qual obteve resultados positivos. Em uma avaliação britânica de custo-efetividade, houve economia de recursos com o auxílio do ultrassom na realização das punções venosas nos diferentes sítios. Fortes evidências demonstram benefício com o auxílio ultrassonográfico para punção jugular interna. Embora o método pareça atraente para os demais sítios, ainda não há estudos suficientes que sustentem alguma recomendação.In recent years, international health quality assurance organizations have been recommending ultrasound guidance for central venous punctures. This article reviews the evidence behind these recommendations. The MEDLINE, PubMed and SCIELO databases were searched for the following MeSH terms: central venous

  14. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  15. Central venous catheterization training: current perspectives on the role of simulation

    Science.gov (United States)

    Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher

    2018-01-01

    Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. PMID:29872360

  16. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    Science.gov (United States)

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  17. Central venous pressure monitoring via peripherally or centrally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Sanfilippo, Filippo; Noto, Alberto; Martucci, Gennaro; Farbo, Marco; Burgio, Gaetano; Biasucci, Daniele G

    2017-07-14

    The central venous pressure (CVP) is the most commonly used static marker of preload for guiding fluid therapy in critically ill patients, though its usefulness remains controversial. Centrally inserted central catheters (CICCs) are the gold-standard devices for CVP monitoring but peripherally inserted central catheters (PICCs) may represent a valid alternative. We undertook a systematic review and meta-analysis with the aim to investigate whether the difference between PICC- and CICC-measured CVP is not significant. We searched for clinical studies published in PubMed and EMBASE databases from inception until December 21st 2016. We included studies providing data on paired and simultaneous CVP measurement from PICCs and CICCs. We conducted two analyses on the values of CVP, the first one according to the total number of CVP assessments, the second one considering the number of patients recruited. Four studies matched the inclusion criteria, but only three of them provided data for the meta-analyses. Both analyses showed non-significant differences between PICC-measured and CICC-measured CVP: 1489 paired simultaneous CVP assessments (MD 0.16, 95%CI -0.14, 0.45, p = 0.30) on a total of 57 patients (MD 0.22, 95%CI -1.46, 1.91, p = 0.80). Both analyses showed no heterogeneity (I2 = 0%). Available evidence supports that CVP monitoring with PICCs is accurate and reproduces similar values to those obtained from CICCs. The possibility to monitor CVP should not be used among clinical criteria for preferring a CICC over a PICC line.

  18. Central venous device-related thrombosis as imaged with MDCT in oncologic patients: prevalence and findings

    International Nuclear Information System (INIS)

    Catalano, Orlando; Castelguidone, Elisabetta de Lutio di; Granata, Vincenza; D'Errico, Adolfo Gallipoli; Sandomenico, Claudia; Petrillo, Mario; Aprea, Pasquale

    2011-01-01

    Background: Venous thrombosis is a common occurrence in cancer patients, developing spontaneously or in combination with indwelling central venous devices (CVD). Purpose: To analyze the multidetector CT (MDCT) prevalence, appearance, and significance of catheter related thoracic venous thrombosis in oncologic patients and to determine the percentage of thrombi identified in the original reports. Material and Methods: Five hundred consecutive patients were considered. Inclusion criteria were: presence of a CVD; availability of a contrast-enhanced MDCT; and cancer history. Exclusion criteria were: direct tumor compression/infiltration of the veins; poor image quality; device tip not in the scanned volume; and missing clinical data. Seventeen (3.5%) out of the final 481 patients had a diagnosis of venous thrombosis. Results: Factors showing the highest correlation with thrombosis included peripherally-inserted CVD, right brachiocephalic vein tip location, patient performance status 3, metastatic stage disease, ongoing chemotherapy, and longstanding CVD. The highest prevalence was in patients with lymphoma, lung carcinoma, melanoma, and gynecologic malignancies. Eleven out of 17 cases had not been identified in the original report. Conclusion: CVD-related thrombosis is not uncommon in cancer patients and can also be observed in outpatients with a good performance status and a non-metastatic disease. Thrombi can be very tiny. Radiologists should be aware of the possibility to identify (or overlook) small thrombi

  19. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein

    OpenAIRE

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-01-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common caro...

  20. Open heart surgery for management of right auricular thrombus related to central venous catheterization.

    Science.gov (United States)

    Ribeiro, A F; Neto, I S; Maia, I; Dias, C

    2018-04-19

    Central venous catheters are widely used in critically ill patients; however, they are also associated with increased morbidity and mortality. The literature may underestimate the incidence of catheter-inducible right atrial thrombi that are asymptomatic but potentially life threatening. The recognized risk factors for its development include infections related to the catheter, endothelial injury secondary to mechanical and chemical damage induced by certain medications and infused fluids. The characteristics of the patient and the catheter, such as size, material, type, location and ease of insertion, as well as the duration of placement play an additional role. We report the case of a 38-year-old man, who developed an asymptomatic catheter-inducible right atrial thrombi requiring open heart surgery, after taking a central venous catheter for thirty-five days. The present case highlights existing limitations in making a correct and fast diagnosis, which should be anticipated in patients with multiple risk factors for thrombosis. Given the limited recommendations available, we consider that the most appropriate strategy should be individualized. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Body surface infrared thermometry in patients with central venous cateter-related infections.

    Science.gov (United States)

    Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio

    2015-01-01

    To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.

  2. Importance of blood cultures from peripheral veins in pediatric patients with cancer and a central venous line

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Rutkjaer, Cecilie

    2015-01-01

    When an infection is suspected in a child with cancer and a central venous line (CVL), cultures are often only obtained from the CVL and not from a peripheral vein (PV). This study was undertaken to evaluate the importance of concomitant blood cultures from the CVL and a PV....

  3. Predictors of Unattempted Central Venous Catheterization in Septic Patients Eligible for Early Goal-directed Therapy

    Directory of Open Access Journals (Sweden)

    David R. Vinson

    2014-02-01

    Full Text Available Introduction: Central venous catheterization (CVC can be an important component of the management of patients with severe sepsis and septic shock. CVC, however, is a time- and resource-intensive procedure associated with serious complications. The effects of the absence of shock or the presence of relative contraindications on undertaking central line placement in septic emergency department (ED patients eligible for early goal-directed therapy (EGDT have not been well described. We sought to determine the association of relative normotension (sustained systolic blood pressure >90 mmHg independent of or in response to an initial crystalloid resuscitation of 20 mL/kg, obesity (body mass index [BMI] ≥30, moderate thrombocytopenia (platelet count <50,000 per μL, and coagulopathy (international normalized ratio ≥2.0 with unattempted CVC in EGDT-eligible patients. Methods: This was a retrospective cohort study of 421 adults who met EGDT criteria in 5 community EDs over a period of 13 months. We compared patients with attempted thoracic (internal jugular or subclavian CVC with those who did not undergo an attempted thoracic line. We also compared patients with any attempted CVC (either thoracic or femoral with those who did not undergo any attempted central line. We used multivariate logistic regression analysis to calculate adjusted odd ratios (AORs. Results: In our study, 364 (86.5% patients underwent attempted thoracic CVC and 57 (13.5% did not. Relative normotension was significantly associated with unattempted thoracic CVC (AOR 2.6 95% confidence interval [CI], 1.6-4.3, as were moderate thrombocytopenia (AOR 3.9; 95% CI, 1.5-10.1 and coagulopathy (AOR 2.7; 95% CI, 1.3-5.6. When assessing for attempted catheterization of any central venous site (thoracic or femoral, 382 (90.7% patients underwent attempted catheterization and 39 (9.3% patients did not. Relative normotension (AOR 2.3; 95% CI, 1.2-4.5 and moderate thrombocytopenia (AOR 3.9; 95

  4. Peripheral Edema, Central Venous Pressure, and Risk of AKI in Critical Illness

    Science.gov (United States)

    Chen, Kenneth P.; Cavender, Susan; Lee, Joon; Feng, Mengling; Mark, Roger G.; Celi, Leo Anthony; Mukamal, Kenneth J.

    2016-01-01

    Background and objectives Although venous congestion has been linked to renal dysfunction in heart failure, its significance in a broader context has not been investigated. Design, setting, participants, & measurements Using an inception cohort of 12,778 critically ill adult patients admitted to an urban tertiary medical center between 2001 and 2008, we examined whether the presence of peripheral edema on admission physical examination was associated with an increased risk of AKI within the first 7 days of critical illness. In addition, in those with admission central venous pressure (CVP) measurements, we examined the association of CVPs with subsequent AKI. AKI was defined using the Kidney Disease Improving Global Outcomes criteria. Results Of the 18% (n=2338) of patients with peripheral edema on admission, 27% (n=631) developed AKI, compared with 16% (n=1713) of those without peripheral edema. In a model that included adjustment for comorbidities, severity of illness, and the presence of pulmonary edema, peripheral edema was associated with a 30% higher risk of AKI (95% confidence interval [95% CI], 1.15 to 1.46; Pedema was not significantly related to risk. Peripheral edema was also associated with a 13% higher adjusted risk of a higher AKI stage (95% CI, 1.07 to 1.20; Pedema were associated with 34% (95% CI, 1.10 to 1.65), 17% (95% CI, 0.96 to 1.14), 47% (95% CI, 1.18 to 1.83), and 57% (95% CI, 1.07 to 2.31) higher adjusted risk of AKI, respectively, compared with edema-free patients. In the 4761 patients with admission CVP measurements, each 1 cm H2O higher CVP was associated with a 2% higher adjusted risk of AKI (95% CI, 1.00 to 1.03; P=0.02). Conclusions Venous congestion, as manifested as either peripheral edema or increased CVP, is directly associated with AKI in critically ill patients. Whether treatment of venous congestion with diuretics can modify this risk will require further study. PMID:26787777

  5. An analysis of leukapheresis and central venous catheter use in the randomized, placebo controlled, phase 3 IMPACT trial of Sipuleucel-T for metastatic castrate resistant prostate cancer.

    Science.gov (United States)

    Flanigan, Robert C; Polcari, Anthony J; Shore, Neil D; Price, Thomas H; Sims, Robert B; Maher, Johnathan C; Whitmore, James B; Corman, John M

    2013-02-01

    Sipuleucel-T is an autologous cellular immunotherapy. We review the safety of the leukapheresis procedure required for sipuleucel-T preparation and complications related to venous catheter use in the randomized, placebo controlled phase 3 IMPACT (IMmunotherapy for ProstAte Cancer Trial) study (NCT 00065442). A total of 512 patients with asymptomatic or minimally symptomatic metastatic castrate resistant prostate cancer were enrolled in the study. All patients were scheduled to undergo 3 standard 1.5 to 2.0 blood volume leukapheresis procedures at 2-week intervals. Leukapheresis related adverse events and those related to venous catheter use were reviewed. Immune cell counts were examined throughout the treatment course. Of 512 enrolled patients 506 underwent 1 or more leukapheresis procedures and were included in this analysis. Adverse events were comparable between the sipuleucel-T and control arms. Leukapheresis related adverse events were primarily associated with transient hypocalcemia (39.3%). Most leukapheresis related adverse events (97%) were of mild/moderate intensity. Median white blood cell count and absolute monocyte and lymphocyte counts were stable and within normal ranges throughout the treatment course. Of all patients 23.3% had a central venous catheter placed primarily for leukapheresis. Patients with vs without a central venous catheter had a higher risk of infection potentially related to catheter use (11.9% vs 1.3%, p nervous system (5.9% vs 2.1%, p = 0.06). Adverse events related to leukapheresis are manageable and quickly reversible. The majority of patients can undergo leukapheresis without a central venous catheter. Central venous catheters are associated with an increased risk of infections and venous vascular events. Peripheral intravenous access should be used when feasible. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2011-01-01

    Shock therapy aims at increasing central venous oxygen saturation (ScvO2), which is a marker of inadequate oxygen delivery. In this issue of Critical Care, Textoris and colleagues challenge this notion by reporting that high levels of ScvO2 are associated with mortality in patients with septic sh...

  7. Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects

    Directory of Open Access Journals (Sweden)

    Łukasz Kalińczuk

    2016-05-01

    Full Text Available Introduction: Totally implantable venous access systems (TIVAS, Swan-Ganz (SG and central venous catheters (CVC allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. Aim : To present results of percutaneous retrieval of embolized fragments of central venous devices or knotted SG and review the procedural aspects with a series of detailed angiographies. Material and methods : Between January 2003 and December 2012 there were 14 (~0.025% successful retrievals in 13 patients (44 ±16 years, 15% females of embolized fragments of TIVAS (n = 10 or CVC (n = 1 or of dislodged guide-wires (n = 2 or knotted SG (n = 1. Results : Foreign bodies with the forward end located in the right ventricle (RV, as well as those found in the pulmonary artery (PA, often required repositioning with a pigtail catheter as compared to those catheter fragments which were located in the right atrium (RA and/or great vein and possessed an accessible free end allowing their direct ensnarement with the loop snare (57.0% (4/7 vs. 66.7% (2/3 vs. 0.0% (0/3; p = 0.074 respectively. Procedure duration was 2–3 times longer among catheters retrieved from the PA than among those with the forward edge located in the RV or RA (30 (18–68 vs. 13.5 (11–37 vs. 8 min (8–13; p = 0.054 respectively. The SG catheter knotted in the vena cava superior (VCS was encircled with the loop snare introduced transfemorally, subsequently cut at its skin entrance and then pulled down inside the 14 Fr vascular sheath. Conclusions : By using the pigtail catheter and the loop snare, it is feasible to retrieve centrally embolized fragments or knotted central venous access devices.

  8. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; Anand, Sarah; Hickner, Andy; Buist, Michael; Rogers, Mary Am; Saint, Sanjay; Flanders, Scott A

    2013-07-27

    Peripherally inserted central catheters (PICCs) are associated with an increased risk of venous thromboembolism. However, the size of this risk relative to that associated with other central venous catheters (CVCs) is unknown. We did a systematic review and meta-analysis to compare the risk of venous thromboembolism associated with PICCs versus that associated with other CVCs. We searched several databases, including Medline, Embase, Biosis, Cochrane Central Register of Controlled Trials, Conference Papers Index, and Scopus. Additional studies were identified through hand searches of bibliographies and internet searches, and we contacted study authors to obtain unpublished data. All human studies published in full text, abstract, or poster form were eligible for inclusion. All studies were of adult patients aged at least 18 years who underwent insertion of a PICC. Studies were assessed with the Newcastle-Ottawa risk of bias scale. In studies without a comparison group, the pooled frequency of venous thromboembolism was calculated for patients receiving PICCs. In studies comparing PICCs with other CVCs, summary odds ratios (ORs) were calculated with a random effects meta-analysis. Of the 533 citations identified, 64 studies (12 with a comparison group and 52 without) including 29 503 patients met the eligibility criteria. In the non-comparison studies, the weighted frequency of PICC-related deep vein thrombosis was highest in patients who were critically ill (13·91%, 95% CI 7·68-20·14) and those with cancer (6·67%, 4·69-8·64). Our meta-analysis of 11 studies comparing the risk of deep vein thrombosis related to PICCs with that related to CVCs showed that PICCs were associated with an increased risk of deep vein thrombosis (OR 2·55, 1·54-4·23, p<0·0001) but not pulmonary embolism (no events). With the baseline PICC-related deep vein thrombosis rate of 2·7% and pooled OR of 2·55, the number needed to harm relative to CVCs was 26 (95% CI 13-71). PICCs are

  9. Biofilm formation in long-term central venous catheters in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Fuursted, Kurt; Funch, Peter

    2012-01-01

    Taurolidine has demonstrated inhibition of biofilm formation in vitro. The aim of this study was to compare the effect of catheter locking with taurolidine vs heparin in biofilm formation in central venous catheters. Forty-eight children with cancer were randomized to catheter locking by heparin (n...... = 22) or taurolidine (n = 26), respectively. After removal, catheters were examined by standardized scanning electron microscopy to assess quantitative biofilm formation. Biofilm was present if morphologically typical structures and bacterial cells were identified. Quantitative and semi...... in the intraluminal biofilm formation and the rate of bacterial colonization detected by scanning electron microscopy in the two groups....

  10. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    OpenAIRE

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 mont...

  11. K time & maximum amplitude of thromboelastogram predict post-central venous cannulation bleeding in patients with cirrhosis: A pilot study

    Directory of Open Access Journals (Sweden)

    Chandra K Pandey

    2017-01-01

    Interpretation & conclusions: Our results show that the cut-off value for INR ≥2.6 and K time ≥3.05 min predict bleeding and MA ≥48.8 mm predicts non-bleeding in patients with cirrhosis undergoing central venous pressure catheter cannulation.

  12. Primary thromboprophylaxis for cancer patients with central venous catheters--a reappraisal of the evidence.

    LENUS (Irish Health Repository)

    Cunningham, M S

    2006-01-30

    Venous thromboembolism (VTE) is responsible for an estimated 25 000 deaths per annum in UK hospital practice. It is well established that many of these deaths could be prevented through the use of appropriate thromboprophylaxis. This issue is of particular relevance in oncology practice, where the risks of VTE and bleeding are both significantly higher than those observed in general medical patients. Cancer patients with in-dwelling central venous catheters (CVCs) are at particularly high risk of developing thrombotic complications. However, the literature has produced conflicting conclusions regarding the efficacy of using routine primary thromboprophylaxis in these patients. Indeed such is the level of confusion around this topic, that the most recent version of the American College of Chest Physicians (ACCP) guidelines published in 2004 actually reversed their previous recommendation (published in 2001). Nevertheless, minidose warfarin continues to be routinely used in many oncology centres in the UK. In this article, we have performed a systematic review of the published literature regarding the efficacy and the risks, associated with using thromboprophylaxis (either minidose warfarin or low-dose LMWH) in cancer patients with CVC. On the basis of this evidence, we conclude that there is no proven role for using such thromboprophylaxis. However, asymptomatic CVC-related venous thrombosis remains common, and further more highly powered studies of better design are needed in order to define whether specific subgroups of cancer patients might benefit from receiving thromboprophylaxis.

  13. Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients

    Science.gov (United States)

    Petrov, Irene Y.; Prough, Donald S.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock is a dangerous medical condition, in which blood flow cannot provide the necessary amount of oxygen to organs and tissues. Currently, its diagnosis and therapy decisions are based on hemodynamic parameters (heart rate, blood pressure, blood gases) and mental status of a patient, which all have low specificity. Measurement of mixed or central venous blood oxygenation via catheters is more reliable, but highly invasive and associated with complications. Our previous studies in healthy volunteers demonstrated that optoacoustic systems provide non-invasive measurement of blood oxygenation in specific vessels, including central veins. Here we report our first results of a clinical study in coronary artery bypass graft (CABG) surgery patients. We used a medical-grade OPO-based optoacoustic system developed in our laboratory to measure in real time blood oxygenation in the internal jugular vein (IJV) of these patients. A clinical ultrasound imaging system (GE Vivid e) was used for IJV localization. Catheters were placed in the IJV as part of routine care and blood samples taken via the catheters were processed with a CO-oximeter. The optoacoustic oxygenation data were compared to the CO-oximeter readings. Good correlation between the noninvasive and invasive measurements was obtained. The results of these studies suggest that the optoacoustic system can provide accurate, noninvasive measurements of central venous oxygenation that can be used for patients with circulatory shock.

  14. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  15. Use of cultivation-dependent and -independent techniques to assess contamination of central venous catheters: a pilot study

    Directory of Open Access Journals (Sweden)

    Høiby Niels

    2008-10-01

    Full Text Available Abstract Background Catheters are the most common cause of nosocomial infections and are associated with increased risk of mortality, length of hospital stay and cost. Prevention of infections and fast and correct diagnosis is highly important. Methods In this study traditional semiquantitative culture-dependent methods for diagnosis of bacteria involved in central venous catheter-related infections as described by Maki were compared with the following culture-independent molecular biological methods: Clone libraries, denaturant gradient gel electrophoresis, phylogeny and fluorescence in situ hybridization. Results In accordance with previous studies, the cultivation of central venous catheters from 18 patients revealed that S. epidermidis and other coagulase-negative staphylococci were most abundant and that a few other microorganisms such as P. aeruginosa and K. pneumoniae occasionally were found on the catheters. The molecular analysis using clone libraries and sequencing, denaturant gradient gel electrophoresis and sequencing provided several important results. The species found by cultivation were confirmed by molecular methods. However, many other bacteria belonging to the phyla Proteobacteria, Firmicutes, Actinobacteria and Bacteroidetes were also found, stressing that only a minor portion of the species present were found by cultivation. Some of these bacteria are known to be pathogens, some have not before been described in relation to human health, and some were not closely related to known pathogens and may represent new pathogenic species. Furthermore, there was a clear difference between the bacterial species found in biofilm on the external (exluminal and internal (luminal side of the central venous catheter, which can not be detected by Maki's method. Polymicrobial biofilms were observed on most of the catheters and were much more common than the cultivation-dependent methods indicated. Conclusion The results show that diagnosis

  16. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  17. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  18. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness

    DEFF Research Database (Denmark)

    Eskesen, T G; Wetterslev, M; Perner, A

    2016-01-01

    PURPOSE: Central venous pressure (CVP) has been shown to have poor predictive value for fluid responsiveness in critically ill patients. We aimed to re-evaluate this in a larger sample subgrouped by baseline CVP values. METHODS: In April 2015, we systematically searched and included all clinical...

  19. Effect of body temperature on peripheral venous pressure measurements and its agreement with central venous pressure in neurosurgical patients.

    Science.gov (United States)

    Sahin, Altan; Salman, M Alper; Salman, A Ebru; Aypar, Ulka

    2005-04-01

    Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical settings. The effect of body temperature on PVP and its agreement with CVP in patients under general anesthesia are investigated in this study. Fifteen American Society of Anesthesiologists I-II patients undergoing elective craniotomy were included in the study. CVP, PVP, and core (Tc) and peripheral (Tp) temperatures were monitored throughout the study. A total of 950 simultaneous measurements of CVP, PVP, Tc, and Tp from 15 subjects were recorded at 5-minute intervals. The measurements were divided into low- and high-Tc and -Tp groups by medians as cutoff points. Bland-Altman assessment for agreement was used for CVP and PVP in all groups. PVP measurements were within range of +/-2 mm Hg of CVP values in 94% of the measurements. Considering all measurements, mean bias was 0.064 mm Hg (95% confidence interval -0.018-0.146). Corrected bias for repeated measurements was 0.173 +/- 3.567 mm Hg (mean +/- SD(corrected)). All of the measurements were within mean +/- 2 SD of bias, which means that PVP and CVP are interchangeable in our setting. As all the measurements were within 1 SD of bias when Tc was > or = 35.8 degrees C, even a better agreement of PVP and CVP was evident. The effect of peripheral hypothermia was not as prominent as core hypothermia. PVP measurement may be a noninvasive alternative for estimating CVP. Body temperature affects the agreement of CVP and PVP, which deteriorates at lower temperatures.

  20. Risk factors for central line-associated bloodstream infection in pediatric oncology patients with a totally implantable venous access port: A cohort study.

    Science.gov (United States)

    Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves

    2017-02-01

    Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.

  1. Elucidating the mechanism of posterior reversible encephalopathy syndrome: a case of transient blindness after central venous catheterization.

    Science.gov (United States)

    Rao, Neal M; Raychev, Radoslav; Kim, Doojin; Liebeskind, David S

    2012-11-01

    Posterior reversible encephalopathy syndrome (PRES) is a condition characterized by reversible symptoms including headache, visual disturbances, focal neurological deficits, altered mentation, and seizures. It has been associated with circumstances that may affect the cerebrovascular system, such as hypertension, eclampsia, and immunosuppression with calcineurin inhibitors. The underlying etiology of PRES has remained unclear; however, cerebrovascular autoregulatory dysfunction, hyperperfusion, and endothelial activation have been implicated. We describe a case of a young patient with lung transplant, who presented with headache, acute binocular blindness, and seizure immediately after infusion of saline through a peripherally inserted central catheter line, which inadvertently terminated cephalad in the left internal jugular vein, near the jugular foramen. Subsequent brain magnetic resonance imaging revealed vasogenic edematous lesions in a pattern consistent with PRES--a diagnosis supported by his constellation of symptoms, history of lung transplantation on tacrolimus immunosuppression, and relative hypertension. This is the first reported case describing the development of PRES after the insertion of a peripherally inserted central catheter line. The development of PRES in a typical high-risk patient immediately after cerebral venous outflow obstruction implicates the role of the cerebral venous system and provides potential insight into the mechanism of this disorder that remains of unclear pathogenesis.

  2. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    Science.gov (United States)

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Serious Gaming to Improve the Safety of Central Venous Catheter Placement

    Directory of Open Access Journals (Sweden)

    Daniel Katz

    2013-06-01

    Full Text Available Approximately 5 million central venous catheters (CVCs are placed by physicians annually in the United States, with a complication rate of 15%.1 Guidelines and recommendations are continually being established and updated regarding CVC placement.2 While much has been done regarding training the technical skills of CVC placement using part-task trainers (i.e., mannequins, successfully finding and cannulating a central vein is but one part of the process. In fact, many steps designed to prevent untoward complications involve non-technical skills which are perhaps more important in training practitioners to safely place CVCs. First in aviation and now in healthcare, practitioners are being trained in realistic and highly interactive simulated environments so they can learn not just technical skills , but the key management and non-technical steps which make their task safer.3 One modality being used to improve performance is video gaming simulation, or "serious gaming." Gaming as a learning tool is being increasingly utilized in health care fields and can lead to better skill-based outcomes.4 As such, we have developed a game based around the placement of CVCs that will be used as a new teaching modality in a pilot program for instructing residents in safe CVC placement.

  4. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    Science.gov (United States)

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  5. Metastatic Carcinoma of Unknown Primary Presenting as Jugular Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Prince Cheriyan Modayil

    2009-01-01

    Full Text Available Jugular venous thrombosis is unusual and is associated with central venous catheterisation, intravenous drug abuse and head and neck sepsis. It is rarely associated with malignancy. We report a case of metastatic carcinoma of unknown primary in a forty year old female which presented with jugular venous thrombosis. The discussion includes investigation and treatment options for this condition.

  6. Regarding optical coherence tomography grading of ischemia in central retinal venous occlusion

    Directory of Open Access Journals (Sweden)

    Tripathy K

    2017-02-01

    Full Text Available Koushik TripathyDepartment of Vitreoretina and Uvea, ICARE Eye Hospital & Postgraduate Institute, Noida, Uttar Pradesh, IndiaThe author read with interest the article by Browning et al.1 The author humbly wants to discuss a few facts.1. The article1 discusses grading of retinal ischemia based on optical coherence tomography features in central retinal venous occlusion. As coexisting central retinal arterial occlusion or cilioretinal arterial occlusion may also cause inner retinal hyper-reflectivity, exclusion of such cases is an important consideration before implicating central retinal venous occlusion for the ischemia. Extensive intraretinal hemorrhages are other important hindrances to the evaluation of the perfusion status of the retina using both fluorescein angiogram and optical coherence tomography.2. It would be interesting to know the gonioscopic findings, especially neovascularization of the anterior chamber angle if it was performed at presentation and during the follow-ups.3. The manuscript documented that the incidence of anterior segment neovascularization at 1 year was 8.9% in severe ischemia group.1 The incidence of anterior segment neovascularization in perfused groups was higher (15.4% and 17.6% for mild and moderate ischemia, respectively. Although the sample size was low, such findings are contrary to the literature2 and require further discussion. Authors' replyDavid J Browning, Omar S Punjabi, Chong LeeDepartment of Ophthalmology, Charlotte Eye, Ear, Nose and Throat Associates, P.A., Charlotte, NC, USA We thank Dr Tripathy for his interest in our article and would respond to his above-mentioned points.1. We agree that excluding eyes with cilioretinal artery and central retinal artery occlusions is necessary to be able to attribute inner retinal reflectivity changes to central retinal vein occlusion. Cilioretinal artery occlusion is associated with a band of ischemic retinal whitening and central retinal artery occlusion

  7. Low central venous pressure with milrinone during living donor hepatectomy.

    Science.gov (United States)

    Ryu, H-G; Nahm, F S; Sohn, H-M; Jeong, E-J; Jung, C-W

    2010-04-01

    Maintaining a low central venous pressure (CVP) has been frequently used in liver resections to reduce blood loss. However, decreased preload carries potential risks such as hemodynamic instability. We hypothesized that a low CVP with milrinone would provide a better surgical environment and hemodynamic stability during living donor hepatectomy. Thirty-eight healthy adult liver donors were randomized to receive either milrinone (milrinone group, n = 19) or normal saline (control group, n = 19) infusion during liver resection. The surgical field was assessed using a four-point scale. Intraoperative vital signs, blood loss, the use of vasopressors and diuretics and postoperative laboratory data were compared between groups. The milrinone group showed a superior surgical field (p milrinone group required smaller amounts of vasopressors and less-frequent diuretics to maintain a low CVP. The milrinone group also showed a more rapid recovery pattern after surgery. Milrinone-induced low CVP improves the surgical field with less blood loss during living donor hepatectomy and also has favorable effects on intraoperative hemodynamics and postoperative recovery.

  8. Central Venous Catheters and Bloodstream Infection During Induction Therapy in Children With Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Bergmann, Kristin; Hasle, Henrik; Asdahl, Peter

    2016-01-01

    The purpose of the study was to assess the risk of firsttime bloodstream infection (BSI) according to type of central venous catheter (CVC) during induction therapy in children with acute lymphoblastic leukemia (ALL). Patients eligible for our analysis were all newly diagnosed children with ALL......-negative blood isolates occurred more frequently in patients with a TE, and that lower incidences of BSI were detected in patients older than 9 years with a TE, and in patients with T-ALL. It is concluded that the type of CVC inserted at diagnosis has no impact upon the risk of BSI in patients with ALL...

  9. Venous access: options, approaches and issues

    International Nuclear Information System (INIS)

    Asch, M.R.

    2001-01-01

    Venous access is an essential part of medical practice. It is needed to obtain blood samples to make the diagnosis and to administer fluids or medicines as part of treatment. Although relatively new in the history of medicine, the placement and maintenance of the various venous access devices now occupies a significant portion of many vascular and interventional radiology practices. Thus, it is important to have a thorough understanding of these devices and their uses. The first long-term venous access devices were used in 1973. These were placed via a surgical cut-down on the subclavian vein. In 1982, the first subcutaneous implantable ports were described. These procedures were initially performed by surgeons, but over the last 5-10 years, both the insertion and management of these devices has shifted to interventional radiologists. Peripherally inserted central catheter (PICC) lines have almost completely supplanted the use of standard central lines (Fig. 1). A number of factors have facilitated this - namely, ready and less expensive room access, outpatient procedure and radiologists' accessibility and familiarity with image-guidance procedures and catheters and guide wires. (author)

  10. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  11. Risk factors for central venous catheter-related infections in a neonatal population – systematic review

    Directory of Open Access Journals (Sweden)

    Viviane Rosado

    2018-01-01

    Full Text Available Objective: This was a systematic review of the incidence density and risk factors for central venous catheter-related infections in a neonatal population. Data source: The MEDLINE, Embase, Cochrane, BDENF, SciELO, and LILACS databases were used without date or language restriction. Studies that analyzed risk factors for bloodstream infections in newborns were identified. Data synthesis: A total of 134 articles were found that met the eligibility criteria. Of these articles, 14 were selected that addressed risk factors for central venous catheter-related infection in neonates. Catheter-related bloodstream infections remain an important complication, as shown by the incidence rates reported in the studies included in this review. The observed risk factors indicate that low birth weight, prematurity, and longer catheter permanence are related to a higher incidence of bloodstream infections. It has been observed that low rates of catheter-related infections, i.e., close to zero, are already a reality in health institutions in developed countries, since they use infection surveillance and control programs. Conclusion: Catheter-related bloodstream infections still show high incidence density rates in developing countries. The authors emphasize the need for further longitudinal studies and the need for better strategies to prevent risk factors, aiming at the reduction of catheter-related infections. Resumo: Objetivo: Trata-se de uma revisão sistemática sobre a densidade de incidência e de fatores de risco para infecção associada a cateter venoso central em população neonatal. Fontes dos dados: Utilizou-se os bancos de dados Medline, Embase, Cochrane, Bdenf, Scielo, Lilacs, sem restrição de data ou de idioma. Identificaram-se os estudos que analisaram fatores de risco para infecção da corrente sanguínea em recém-nascidos. Síntese dos dados: Foram encontrados 134 artigos conforme os critérios de elegibilidade. Destes artigos, foram

  12. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    International Nuclear Information System (INIS)

    Desai, Shamit S.; Konanur, Meghana; Foltz, Gretchen; Malaisrie, S. Chris; Resnick, Scott

    2016-01-01

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period

  13. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu [Northwestern Memorial Hospital, Department of Radiology (United States); Konanur, Meghana [Northwestern University Feinberg School of Medicine (United States); Foltz, Gretchen [Mallinckrodt Institute of Radiology at Washington University, Interventional Radiology (United States); Malaisrie, S. Chris [Northwestern Memorial Hospital, Department of Cardiothoracic Surgery (United States); Resnick, Scott, E-mail: sresnick@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology, Interventional Radiology, Northwestern Memorial Hospital (United States)

    2016-03-15

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.

  14. Primary Stenting Is Not Necessary in Benign Central Venous Stenosis.

    Science.gov (United States)

    Rangel, Lynsey E; Lyden, Sean P; Clair, Daniel G

    2018-01-01

    The aim of this study is to evaluate central venous stenosis (CVS) etiologies and presentation within a vascular surgery practice. We evaluated endovascular treatment modalities and the patency rates of our interventions. Five-year retrospective review of endovascular intervention for CVS. Patient demographics, medical comorbidities, and variables were collected including etiology, indwelling device, previous upper extremity (UE) deep venous thrombosis, long-term UE indwelling device (defined as >30 days), malignancy status, hypercoagulable disorders, history of radiation or mediastinal fibrosis or masses, and anticoagulation and/or antiplatelet therapy. Follow-up variables included symptoms, imaging, and anticoagulation and/or antiplatelet utilization. Living patients without recent follow-up were contacted with a telephone survey regarding current symptoms. Patency was evaluated by imaging or clinically by recurrence of signs or symptoms through January 2016. A total of 61 patients underwent attempted endovascular CVS interventions from January 2007 to 2013. Forty-seven (83%) patients had successful interventions. There were 22 (36%) end-stage renal disease (ESRD) patients. The primary etiology in 79% of patients was benign CVS secondary to an indwelling device. Eighty-nine percent of the interventions were primary angioplasty (PTA). The overall primary patency rates at 6, 12, and 24 months were 49%, 34%, and 24%, respectively. Secondary patency rates at 6, 12, and 24 months were 97%, 93%, and 88%, respectively. There were no statistical differences in demographics or outcomes in patients treated successfully with PTA or those requiring stenting. There was no statistical difference in the patency rates between ESRD and non-ESRD patients. Previous interventions were not a predictor of loss of patency. Our study supported the rising trend of benign CVS predominantly secondary to indwelling devices. We demonstrated acceptable secondary patency with PTA alone

  15. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  16. Guidewire retention following central venous catheterisation: a human factors and safe design investigation.

    Science.gov (United States)

    Horberry, Tim; Teng, Yi-Chun; Ward, James; Patil, Vishal; Clarkson, P John

    2014-01-01

    Central Venous Catheterisation (CVC) has occasionally been associated with cases of retained guidewires in patients after surgery. In theory, this is a completely avoidable complication; however, as with any human procedure, operator error leading to guidewires being occasionally retained cannot be fully eliminated. The work described here investigated the issue in an attempt to better understand it both from an operator and a systems perspective, and to ultimately recommend appropriate safe design solutions that reduce guidewire retention errors. Nine distinct methods were used: observations of the procedure, a literature review, interviewing CVC end-users, task analysis construction, CVC procedural audits, two human reliability assessments, usability heuristics and a comprehensive solution survey with CVC end-users. The three solutions that operators rated most highly, in terms of both practicality and effectiveness, were: making trainees better aware of the potential guidewire complications and strongly emphasising guidewire removal in CVC training, actively checking that the guidewire is present in the waste tray for disposal, and standardising purchase of central line sets so that differences that may affect chances of guidewire loss is minimised. Further work to eliminate/engineer out the possibility of guidewires being retained is proposed.

  17. A comparison between two types of central venous catheters in the prevention of catheter-related infections: the importance of performing all the relevant cultures

    NARCIS (Netherlands)

    van Vliet, J.; Leusink, J.A.; de Jongh, B.M.; de Boer, A.

    2001-01-01

    Objective: to determine the efficacy of double-lumen central venous catheters coated with chlorhexidine and silver-sulfadiazine in reducing the incidence of catheter-related infections. Design: a randomized controlled trial. Setting: medical-surgical intensive care unit of a 600-bed teaching

  18. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    Science.gov (United States)

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  19. Risk factors for venous port migration in a single institute in Taiwan

    OpenAIRE

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-01

    Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiw...

  20. Radiologists need to be aware of secondary central venous stenosis in patients with SAPHO syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Mizuho; Kanazawa, Hidenori; Shinozaki, Takeshi; Sugimoto, Hideharu [Jichi Medical University, Department of Radiology, Shimotsuke, Tochigi (Japan)

    2017-11-15

    We aimed to define central venous stenosis (CVS) caused by sternocostoclavicular hyperostosis as a feature of synovitis-acne-pustulosis-hyperostosis-osteitis (SAPHO) syndrome on routine contrast-enhanced computed tomography (CT) images. The relationship between SAPHO syndrome and CVS without venous thrombosis caused by anterior chest wall compression has not been investigated. Therefore, the present study evaluated CVS in patients with SAPHO syndrome at our hospital. We retrospectively reviewed contrast-enhanced CT images of ten patients with suspected or diagnosed SAPHO syndrome between January 2007 and November 2015. The patients were assessed by contrast-enhanced CT using 16-, 64- or 128-detector row scanners. Two radiologists independently assessed the presence of CVS or obstruction and SAPHO syndrome in a retrospective review of CT images. Six of the ten patients had findings of CVS with SAPHO syndrome. The mean diameter and patency rate at the site of CVS were 1.88 mm and 27.2%, respectively. Stenosis was more significant in terms of the mean diameter of CVS sites than of stenotic sites that crossed the anteroposterior vein (p < 0.05). Radiologists who routinely assess contrast-enhanced CT images should be aware that sternocostoclavicular hyperostosis with SAPHO syndrome could cause secondary CVS. (orig.)

  1. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  2. A systematic review of extravasation and local tissue injury from administration of vasopressors through peripheral intravenous catheters and central venous catheters.

    Science.gov (United States)

    Loubani, Osama M; Green, Robert S

    2015-06-01

    The aim of this study was to collect and describe all published reports of local tissue injury or extravasation from vasopressor administration via either peripheral intravenous (IV) or central venous catheter. A systematic search of Medline, Embase, and Cochrane databases was performed from inception through January 2014 for reports of adults who received vasopressor intravenously via peripheral IV or central venous catheter for a therapeutic purpose. We included primary studies or case reports of vasopressor administration that resulted in local tissue injury or extravasation of vasopressor solution. Eighty-five articles with 270 patients met all inclusion criteria. A total of 325 separate local tissue injury and extravasation events were identified, with 318 events resulting from peripheral vasopressor administration and 7 events resulting from central administration. There were 204 local tissue injury events from peripheral administration of vasopressors, with an average duration of infusion of 55.9 hours (±68.1), median time of 24 hours, and range of 0.08 to 528 hours. In most of these events (174/204, 85.3%), the infusion site was located distal to the antecubital or popliteal fossae. Published data on tissue injury or extravasation from vasopressor administration via peripheral IVs are derived mainly from case reports. Further study is warranted to clarify the safety of vasopressor administration via peripheral IVs. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Maximal venous outflow velocity: an index for iliac vein obstruction.

    Science.gov (United States)

    Jones, T Matthew; Cassada, David C; Heidel, R Eric; Grandas, Oscar G; Stevens, Scott L; Freeman, Michael B; Edmondson, James D; Goldman, Mitchell H

    2012-11-01

    Leg swelling is a common cause for vascular surgical evaluation, and iliocaval obstruction due to May-Thurner syndrome (MTS) can be difficult to diagnose. Physical examination and planar radiographic imaging give anatomic information but may miss the fundamental pathophysiology of MTS. Similarly, duplex ultrasonographic examination of the legs gives little information about central impedance of venous return above the inguinal ligament. We have modified the technique of duplex ultrasonography to evaluate the flow characteristics of the leg after tourniquet-induced venous engorgement, with the objective of revealing iliocaval obstruction characteristic of MTS. Twelve patients with signs and symptoms of MTS were compared with healthy control subjects for duplex-derived maximal venous outflow velocity (MVOV) after tourniquet-induced venous engorgement of the leg. The data for healthy control subjects were obtained from a previous study of asymptomatic volunteers using the same MVOV maneuvers. The tourniquet-induced venous engorgement mimics that caused during vigorous exercise. A right-to-left ratio of MVOV was generated for patient comparisons. Patients with clinical evidence of MTS had a mean right-to-left MVOV ratio of 2.0, asymptomatic control subjects had a mean ratio of 1.3, and MTS patients who had undergone endovascular treatment had a poststent mean ratio of 1.2 (P = 0.011). Interestingly, computed tomography and magnetic resonance imaging results, when available, were interpreted as positive in only 53% of the patients with MTS according to both our MVOV criteria and confirmatory venography. After intervention, the right-to-left MVOV ratio in the MTS patients was found to be reduced similar to asymptomatic control subjects, indicating a relief of central venous obstruction by stenting the compressive MTS anatomy. Duplex-derived MVOV measurements are helpful for detection of iliocaval venous obstruction, such as MTS. Right-to-left MVOV ratios and

  4. Total anomalous systemic venous drainage in left heterotaxy syndrome.

    Science.gov (United States)

    Khandenahally, Ravindranath S; Deora, Surender; Math, Ravi S

    2013-04-01

    Total anomalous systemic venous drainage is an extremely rare congenital heart defect. In this study we describe an 11-year-old girl who presented with a history of fatigue and central cyanosis that she had had since early childhood with unremarkable precordial examination results. Investigations revealed left heterotaxy with all systemic venous drainage to the left-sided atrium with non-compaction of the left ventricle.

  5. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    Science.gov (United States)

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  6. Central Venous Catheter (CVC related infections: a local retrospective study

    Directory of Open Access Journals (Sweden)

    Manuela Fresu

    2008-06-01

    Full Text Available Background. Central venous catheter (CVC related infection is associated with significant increases in morbidity, mortality, and health care cost.This local surveillance study was carry out to monitor the frequency of occurrence of CVC-related blood stream infections. Materials and methods. During the period January – December 2005, 226 CVC specimens were analyzed (quantitative method and microrganism identification from positive samples was performed by Vitek II. In 53 patients it was possible to compare quantitative results with those obtained from blood cultures. Results. Positive CVC samples were 125 (55% and 130 microrganisms were isolated: 109 Gram-positives (84%, 4 Gram-negatives (3%, and 17 mycetes (13%. Among pathogens collected simultaneously from CVC and blood samples, the most frequently isolated were Staphylococcus spp. (30% coagulase-negative staphylococci and 20%. S. aureus and Candida spp. (45%. In the group of patients that presented positive CVC and negative blood samples the most frequently recovered microrganisms were staphylococci. Many isolates (33% were polymicrobial. Conclusions. Catheter-related infections occurred in those patients who presented the same pathogen in both CVC and blood cultures. These infections were principally caused by staphylococci and Candida spp. On the contrary, a possible CVC contamination could be suspected when positive CVC and negative blood cultures were found.

  7. Rhodococcus equi venous catheter infection: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Nahleh Zeina

    2011-08-01

    Full Text Available Abstract Introduction Rhodococcus equi is an animal pathogen that was initially isolated from horses and is being increasingly reported as a cause of infection in humans with impaired cellular immunity. However, this pathogen is underestimated as a challenging antagonist and is frequently considered to be a mere contaminant despite the potential for life-threatening infections. Most case reports have occurred in immunocompromised patients who have received organ transplants (for example kidney, heart, bone marrow or those with human immunodeficiency virus infection. Infections often manifest as pulmonary involvement or soft tissue abscesses. Bacteremia related to R. equi infections of tunneled central venous catheters has rarely been described. Case presentation We report the case of a 63-year-old non-transplant recipient, non-HIV infected Caucasian woman with endometrial carcinoma who developed recurrent bloodstream infections and septic shock due to R. equi and ultimately required the removal of her port catheter, a subcutaneous implantable central venous catheter. We also review the medical literature related to human infections with R. equi. Conclusion R. equi should be considered a serious pathogen, not a contaminant, particularly in an immunocompromised patient who presents with a central venous catheter-related bloodstream infection. Counseling patients with central venous catheters who participate in activities involving exposure to domesticated animals is recommended.

  8. [Venous thrombosis of atypical location in patients with cancer].

    Science.gov (United States)

    Campos Balea, Begoña; Sáenz de Miera Rodríguez, Andrea; Antolín Novoa, Silvia; Quindós Varela, María; Barón Duarte, Francisco; López López, Rafael

    2015-01-01

    Venous thromboembolism (VTE) is a complication that frequently occurs in patients with neoplastic diseases. Several models have therefore been developed to identify patient subgroups diagnosed with cancer who are at increased risk of developing VTE. The most common forms of thromboembolic episodes are deep vein thrombosis in the lower limbs and pulmonary thromboembolism. However, venous thrombosis is also diagnosed in atypical locations. There are few revisions of unusual cases of venous thrombosis. In most cases, VTE occurs in the upper limbs and in the presence of central venous catheters, pacemakers and defibrillators. We present the case of a patient diagnosed with breast cancer and treated with surgery, chemotherapy and radiation therapy who developed a thrombosis in the upper limbs (brachial and axillary). Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  9. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  10. [Subcutaneous implantation type central venous port management in patients with malignant tumors effect of different antiseptic agents on central venous port-related infection].

    Science.gov (United States)

    Sato, Junya; Kumagai, Masumi; Kato, Kenichi; Akahane, Akio; Suzuki, Michiko; Kashiwaba, Masahiro; Sone, Miyuki; Kudo, Kenzo

    2014-08-01

    Subcutaneous implantation type central venous ports(CV ports)are used in chemotherapy. Here, we prospectively examined the frequency of CV port-related infections when the disinfectant was changed from 10% povidone iodine to 1% chlorhexidine ethanol or 70% ethanol. The subjects were patients with malignant tumors, who had newly been implanted with CV ports. We examined CV port-related infections at 1 week after CV port implantation and every 2 weeks thereafter, following sterilization upon insertion of a Huber needle to the CV port. CV port evulsion due to CV port-related infection was noted in 3 patients(4.8%)in whom 15%chlorhexidine ethanol was used(n=62)and in 2 patients(3.3%)in whom 70% ethanol was used(n=60). Infection rates per 1,000 days of CV port use were 1.48% and 1.01%, respectively. Thus, the outcomes of sterilization using 1% chlorhexidine ethanol and 70% ethanol did not differ significantly from those on using 10% povidone iodine for sterilization, based on preliminary results at our institution(3 of 59 patients[5.1%]had port evulsion due to CV port-related infection and the infection rate per 1,000 days of CV port use was 1.47%, Akahane et al, 2012). Chlorhexidine ethanol and ethanol are very convenient to use because they dry quickly and do not need discoloration. Accordingly, chlorhexidine ethanol and ethanol might be useful in CV port management.

  11. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?

    International Nuclear Information System (INIS)

    Wattjes, M.P.; Doepp, F.; Bendszus, M.; Fiehler, J.

    2011-01-01

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  12. Computer Identification of Symptomatic Deep Venous Thrombosis Associated with Peripherally Inserted Central Catheters

    Science.gov (United States)

    Evans, R. Scott; Linford, Lorraine H.; Sharp, Jamie H.; White, Gayle; Lloyd, James F.; Weaver, Lindell K.

    2007-01-01

    Peripherally inserted central catheters (PICCs) are considered a safe method to provide long-term antibiotic therapy, chemotherapy and nutrition support. Deep venous thrombosis (DVT) is a complication that requires early PICC removal, may extend hospitalization and can result in pulmonary embolism. PICC insertion teams strive to understand risk factors and develop methods to prevent DVTs. However, they can only manage what they can measure. At LDS Hospital, identification of PICC associated DVTs was dependent on verbal notification or manual surveillance of more than a thousand free-text vascular reports. Accurate DVT rates were not known which hindered prevention. We describe the development of a computer application (PICC-DVT monitor) to identify PICC associated DVTs each day. A one-year evaluation of the monitor by the PICC team and a review of 445 random vascular reports found a positive predictive value of 98%, sensitivity of 94%, specificity of 100% and a PICC team associated DVT rate of 2.8%. PMID:18693831

  13. Cost of installing and turning off hemodialysis on patients with central venous catheters

    Directory of Open Access Journals (Sweden)

    Gillene Santos Ferreira

    2014-12-01

    Full Text Available The objective was to identify the average total cost (ATC for installing and turning off hemodialysis on patients with central venous catheters. This quantitative, exploratory, and descriptive research, in the mode of a single-case study, was conducted in a public university hospital. The non-probabilistic sample corresponded to the observation of 100 installations and 100 terminations of hemodialysis on 42 patients during 23 days of collection. The ATC was calculated by multiplying the time spent by nurses by the unit cost of direct labor, and adding the cost of materials, solutions, and medications. The Brazilian currency (R$ was used for the calculations. The ATC for installation was R$ 80.10 and for shutting off was R$ 13.04, totaling R$ 93.14 per hemodialysis session. The results obtained will facilitate a better planning of the allocation of human, material, and financial resources enabling the increase of managerial strategies aimed at economic efficiency. doi: 10.5216/ree.v16i4.23044.

  14. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  15. Nitroglycerine and patient position effect on central, hepatic and portal venous pressures during liver surgery.

    Science.gov (United States)

    Sand, L; Lundin, S; Rizell, M; Wiklund, J; Stenqvist, O; Houltz, E

    2014-09-01

    To reduce blood loss during liver surgery, a low central venous pressure (CVP) is recommended. Nitroglycerine (NG) with its rapid onset and offset can be used to reduce CVP. In this study, the effect of NG on portal and hepatic venous pressures (PVP and HVP) in different body positions was assessed. Thirteen patients undergoing liver resection were studied. Cardiac output (CO), mean arterial pressure (MAP) and CVP were measured. PVP and HVP were measured using tip manometer catheters at baseline (BL) in horizontal position; during NG infusion, targeting a MAP of 60 mmHg, with NG infusion and the patient placed in 10 head-down position. NG infusion reduced HVP from 9.7 ± 2.4 to 7.2 ± 2.4, PVP from 12.3 ± 2.2 to 9.7 ± 3.0 and CVP from 9.8 ± 1.9 to 7.2 ± 2.1 mmHg at BL. Head-down tilt during ongoing NG resulted in increases in HVP to 8.2 ± 2.1, PVP to 10.7 ± 3 and CVP to 11 ± 1.9 mmHg. CO at BL was 6.3 ± 1.1, which was reduced by NG to 5.8 ± 1.2. Head-down tilt together with NG infusion restored CO to 6.3 ± 1.0 l/min. NG infusion leads to parallel reductions in CVP, HVP and PVP at horizontal body position. Thus, CVP can be used to guide NG dosage and fluid administration at horizontal position. NG infusion can be used to reduce HVP. Head-down tilt can be used during NG infusion to improve both blood pressure and CO without substantial increase in liver venous pressure. In head-down tilt, CVP dissociates from HVP and PVP. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  17. Intramuscular ketamine to facilitate pediatric central vascular access.

    Science.gov (United States)

    Denmark, T Kent; Hargrove, Jenny R; Brown, Lance

    2004-07-01

    Obtaining prompt vascular access in young children presenting to the emergency department (ED) is frequently both necessary and technically challenging. The objective of our study was to describe our experience using intramuscular (IM) ketamine to facilitate the placement of central venous catheters in children presenting to our ED needing vascular access in a timely fashion. We performed a retrospective medical record review of all pediatric patients central venous catheter facilitated by the use of IM ketamine. Eleven children met our inclusion criteria. Most of the children were young and medically complicated. The children ranged in age from 6 months to 8 years. The only complication identified was vomiting experienced by an 8-year-old boy. Emergency physicians successfully obtained central venous access in all subjects in the case series. The use of IM ketamine to facilitate the placement of central venous catheters in children who do not have peripheral venous access appears to be helpful. Emergency physicians may find it useful to be familiar with this use of IM ketamine.

  18. Tricuspid valve endocarditis following central venous cannulation: The increasing problem of catheter related infection

    Directory of Open Access Journals (Sweden)

    Suresh Babu Kale

    2013-01-01

    Full Text Available A central venous catheter (CVC is inserted for measurement of haemodynamic variables, delivery of nutritional supplements and drugs and access for haemodialysis and haemofiltration. Catheterization and maintenance are common practices and there is more to the technique than routine placement as evident when a procedure-related complication occurs. More than 15% of the patients who receive CVC placement have some complications and infectious endocarditis involving the tricuspid valve is a rare and serious complication with high morbidity and mortality. Overenthusiastic and deep insertion of the guide wire and forceful injection through the CVC may lead to injury of the tricuspid valve and predispose to bacterial deposition and endocarditis. We report a case of tricuspid valve endocarditis, probably secondary to injury of the anterior tricuspid leaflet by the guide wire or the CVC that required open heart surgery with vegetectomy and repair of the tricuspid valve.

  19. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study.

    Science.gov (United States)

    Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe

    2015-01-01

    The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.

  20. Central nervous system decompression sickness and venous gas emboli in hypobaric conditions.

    Science.gov (United States)

    Balldin, Ulf I; Pilmanis, Andrew A; Webb, James T

    2004-11-01

    Altitude decompression sickness (DCS) that involves the central nervous system (CNS) is a rare but potentially serious condition. Identification of early symptoms and signs of this condition might improve treatment. We studied data from 26 protocols carried out in our laboratory over the period 1983-2003; all were designed to provoke DCS in a substantial proportion of subjects. The data set included 2843 cases. We classified subject-exposures that resulted in DCS as: 1) neurological DCS of peripheral and/or central origin (NEURO); 2) a subset of those that involved only the CNS (CNS); and 3) all other cases, i.e., DCS cases that did not have a neurological component (OTHER). For each case, echo imaging data were used to document whether venous gas emboli (VGE) were present, and their level was classified as: 1) any level, i.e., Grade 1 or higher (VGE-1); and 2) high level, Grade 4 (VGE-4). There were 1108 cases of altitude DCS in the database; 218 were classified as NEURO and 49 of those as CNS. VGE-1 were recorded in 83.8% of OTHER compared with 58.7% of NEURO and 55.1% of CNS (both p Hyperbaric oxygen (HBO) was used to treat about half of the CNS cases, while all other cases were treated with 2 h breathing 100% oxygen at ground level. Since only about half of the rare cases of hypobaric CNS DCS cases were accompanied by any level of VGE, echo imaging for bubbles may have limited application for use as a predictor of such cases.

  1. Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?

    Science.gov (United States)

    Martyak, Michael; Kabir, Ishraq; Britt, Rebecca

    2017-08-01

    Peripherally inserted central venous catheters (PICCs) are now commonly used for central access in the intensive care unit (ICU) setting; however, there is a paucity of data evaluating the complication rates associated with these lines. We performed a retrospective review of all PICCs placed in the inpatient setting at our institution during a 1-year period from January 2013 to December 2013. These were divided into two groups: those placed at the bedside in the ICU and those placed by interventional radiology in non-ICU patients. Data regarding infectious and thrombotic complications were collected and evaluated. During the study period, 1209 PICC line placements met inclusion criteria and were evaluated; 1038 were placed by interventional radiology in non-ICU patients, and 171 were placed at the bedside in ICU patients. The combined thrombotic and central line associated blood stream infection rate was 6.17 per cent in the non-ICU group and 10.53 per cent in the ICU group (P = 0.035). The thrombotic complication rate was 5.88 per cent in the non-ICU group and 7.60 per cent in the ICU group (P = 0.38), whereas the central line associated blood stream infection rate was 0.29 per cent in the non-ICU group and 2.92 per cent in the ICU group (P = 0.002). This study seems to suggest that PICC lines placed at the bedside in the ICU setting are associated with higher complication rates, in particular infectious complications, than those placed by interventional radiology in non-ICU patients. The routine placement of PICC lines in the ICU settings needs to be reevaluated given these findings.

  2. A case-control study to identify risk factors for totally implantable central venous port-related bloodstream infection.

    Science.gov (United States)

    Lee, Guk Jin; Hong, Sook Hee; Roh, Sang Young; Park, Sa Rah; Lee, Myung Ah; Chun, Hoo Geun; Hong, Young Seon; Kang, Jin Hyoung; Kim, Sang Il; Kim, Youn Jeong; Chun, Ho Jong; Oh, Jung Suk

    2014-07-01

    To date, the risk factors for central venous port-related bloodstream infection (CVPBSI) in solid cancer patients have not been fully elucidated. We conducted this study in order to determine the risk factors for CVP-BSI in patients with solid cancer. A total of 1,642 patients with solid cancer received an implantable central venous port for delivery of chemotherapy between October 2008 and December 2011 in a single center. CVP-BSI was diagnosed in 66 patients (4%). We selected a control group of 130 patients, who were individually matched with respect to age, sex, and catheter insertion time. CVP-BSI occurred most frequently between September and November (37.9%). The most common pathogen was gram-positive cocci (n=35, 53.0%), followed by fungus (n=14, 21.2%). Multivariate analysis identified monthly catheter-stay as a risk factor for CVP-BSI (p=0.000), however, its risk was lower in primary gastrointestinal cancer than in other cancer (p=0.002). Initial metastatic disease and long catheter-stay were statistically significant factors affecting catheter life span (p=0.005 and p=0.000). Results of multivariate analysis showed that recent transfusion was a risk factor for mortality in patients with CVP-BSI (p=0.047). In analysis of the results with respect to risk factors, prolonged catheter-stay should be avoided as much as possible. It is necessary to be cautious of CVP-BSI in metastatic solid cancer, especially non-gastrointestinal cancer. In addition, avoidance of unnecessary transfusion is essential in order to reduce the mortality of CVP-BSI. Finally, considering the fact that confounding factors may have affected the results, conduct of a well-designed prospective controlled study is warranted.

  3. ["Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter].

    Science.gov (United States)

    Mutti, Carolina; Fumagalli, Anna; Monni, Pierina; Rancati, Stefania; Rosi, Ivana Maria

    2016-01-01

    . "Let me tell you about my little box": phenomenological study on the experience of living with a totally implantable central venous catheter. Many variables impact on the choice to implant a totally implantable long-term central venous catheter's (Port), in spite of its proven efficacy. The patients' perception is pivotal, and only few qualitative studies dig deep into patients' feelings and experiences. To understand if, and how, the Port affects the patient's life. Qualitative phenomenological study based on semi-structured interviews on a convenience sample of patients implanted a Port, selected in an oncohematology Day Hospital in Milan. The analysis was carried out by three researchers with a phenomenological method. Four main themes, and sub-themes, emerged from twenty interviews. Relief, both physical and psychological; the process of the choice of inserting the Port and the importance of thinking about its positioning since the beginning of the treatment course; the symbol- the device reminds of the disease and its removal is of utmost importance; the technology progresses- the need of trust in the health care personnel and in their competences. The Port improved the patients' quality of life. The study allows some reflections on the need of considering the actual and future conditions of the patient to make a shared and informed choice.

  4. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    Science.gov (United States)

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  5. [Procedure adverse events: nursing care in central venous catheter fracture].

    Science.gov (United States)

    Pérez-Juan, Eva; Maqueda-Palau, Mònica; Romero-Grilo, Cristina; Muñoz-Moles, Yolanda

    2014-01-01

    In a intensive care unit (ICU) there are many factors that can lead to the occurrence of adverse events. A high percentage of these events are associated with the administration of drugs. Diagnostic tests, such as computed tomography, is common in critically ill patients and technique can be performed with injection of contrast agent to enhance the visualization of soft tissue. The contrast is a medication and the nurse is responsible for its proper administration. The management of the critically ill patient is complex. ICU team and radiology shares responsibility for the care and safety of the patient safety during the transfer and performing tests with contrast. The World Health Organisation patient safety strategies, recommends analysing errors and learning from them. Therefore, it was decided to investigate the causes of the category E severity adverse events that occurred in a patient who was admitted to the ICU for septic shock of abdominal origin. An abdominal computed tomography was performed with contrast which was injected through a central venous catheter. The contrast did not appear in the image. What happened? Causal analysis helped to understand what triggered the event. A care plan and an algorithm were drafted to prevent it from happening again, with the following objectives: improving knowledge, skills and promoting positive attitudes towards patient safety, working at primary, secondary and tertiary care levels. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  6. Remifentanil for the insertion and removal of long-term central venous access during monitored anesthesia care.

    LENUS (Irish Health Repository)

    Burlacu, Crina L

    2012-02-01

    STUDY OBJECTIVE: To determine the analgesic efficacy of three different rates of remifentanil infusion in patients undergoing insertion or removal of long-term central venous access devices during monitored anesthesia care and local anesthetic field infiltration. DESIGN: Double-blinded, randomized, controlled study. SETTING: Operating theatre of an University hospital. PATIENTS: 44 unpremedicated, ASA physical status 1 and 2 patients, aged 18-65 years, undergoing insertion or removal of a Port-a-Cath or Hickman catheter. INTERVENTIONS: Patients sedated with a propofol target-controlled infusion were randomly allocated to three groups: Group R25 (n = 14), Group R50 (n = 15), and Group R75 (n = 15), to receive remifentanil 0.025, 0.05, and 0.075 mug\\/kg\\/min, respectively. Rescue remifentanil 0.5 mug\\/kg was administered for pain scores > 3. The remifentanil infusion rate was maintained constant unless respiratory and\\/or cardiovascular unwanted events occurred, whereupon the rate was adjusted in 0.01 mug\\/kg\\/min decrements as necessary. MEASUREMENTS: Pain scores (primary outcome), sedation, and movement scores (secondary outcomes) were assessed during local anesthetic infiltration of the anterior chest wall and 5 other procedural steps. MAIN RESULTS: All infusion rates had equal analgesic efficacy, as shown by comparable pain scores, number of rescue boluses, and number of patients requiring rescue analgesia. Excessive sedation was associated with the highest remifentanil rate such that Group R75 patients were significantly more sedated than Groups R25 or R50 at selective procedural steps (P < 0.05). More Group R75 patients (6\\/15) required remifentanil rate reduction than did patients from Group R50 (1\\/15) or Group R25 (0\\/14), P < 0.01, most commonly because of respiratory depression. CONCLUSIONS: For the insertion or removal of long-term central venous access devices, all three remifentanil infusion rates proved to be equally analgesic

  7. Spontaneous fracture of implanted central venous catheters in cancer patients: report of two cases and retrospective analysis of the 'pinch-off sign' as a risk factor

    NARCIS (Netherlands)

    Punt, C. J.; Strijk, S.; van der Hoeven, J. J.; van de Sluis, R.; Verhagen, C. A.

    1995-01-01

    Spontaneous fracture of central venous catheters (CVC) has been reported. It results from repeated compression of the extravasal part of the CVC between the clavicle and the first rib. The so called pinch-off sign (POS) of the CVC as visible on a chest radiograph has been described as a warning for

  8. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.; Siegel, Randall L.; Biswal, Rajiv; Gribbin, Christopher E.; Tokarz, Robert

    2000-01-01

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. A combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant

  9. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    Science.gov (United States)

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia.

    Science.gov (United States)

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  11. Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study.

    Science.gov (United States)

    Lanspa, Michael J; Brown, Samuel M; Hirshberg, Eliotte L; Jones, Jason P; Grissom, Colin K

    2012-12-01

    Volume expansion is a common therapeutic intervention in septic shock, although patient response to the intervention is difficult to predict. Central venous pressure (CVP) and shock index have been used independently to guide volume expansion, although their use is questionable. We hypothesize that a combination of these measurements will be useful. In a prospective, observational study, patients with early septic shock received 10-mL/kg volume expansion at their treating physician's discretion after brief initial resuscitation in the emergency department. Central venous pressure and shock index were measured before volume expansion interventions. Cardiac index was measured immediately before and after the volume expansion using transthoracic echocardiography. Hemodynamic response was defined as an increase in a cardiac index of 15% or greater. Thirty-four volume expansions were observed in 25 patients. A CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less individually had a good negative predictive value (83% and 88%, respectively). Of 34 volume expansions, the combination of both a high CVP and a low shock index was extremely unlikely to elicit hemodynamic response (negative predictive value, 93%; P = .02). Volume expansion in patients with early septic shock with a CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less is unlikely to lead to an increase in cardiac index. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. CENTRAL VENOUS CATHETER AS A VASCULAR APPROACH TO HEMODIALYSTS

    Directory of Open Access Journals (Sweden)

    Verica Djordjevic

    2001-03-01

    Full Text Available The application of the central venous catheter (CVC as a temporary orpermanent vascular approach to hemodialysis has been practiced in our Center since1994. So far 30 (12,6% patients have been thus treated. The primary application hasbeen done in 25 patients, namely: the first making of the A V fistula has been done in16, the ABT in 6, while the vascular approach correction in 3 patients. The secondaryapplication has been done in 5 patients. The infection episode incidence concerningthe CVC application is 20 infections per 1.000 patients. This is the upper limitaccording to the data given in the literature (5, rang 3-20. The average duration of thecatheter is 21 + - 13 days (rang 1-47. Two-volume catheters have been used for ajugular approach though less often for a femoral one. The unsuccessful placing due tothe catheter thrombosis has occurred in 4 patients, the catheter drop-out and itsreplacing have been done in 2 patients, while no replacement has happened in onečaše. The treatment has been stopped in one patient. Tn four patients the cerebrovascularinsult has happened after placing the CVC. The mortality rate is 26,6%,that is, K patients, namely: 4 due to cerebrovascular insult, one due to lung emboly,one due to heart weakness and one due to the sepsis from the V fistula. One patientdied at home for unknown reason. A high infection episode incidence rate is related toinadequate patients' placing so that their location in the rooms for intensive care is away of reducing it. It is necessary to provide for general aseptic procedure at work aswell as for betterment of the accompanying procedures (hemoculture, antibiograms,sterilization in order to maintain a safe catheter function.

  13. Current situation regarding central venous port implantation procedures and complications: a questionnaire-based survey of 11,693 implantations in Japan.

    Science.gov (United States)

    Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi

    2016-12-01

    We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.

  14. Fatal central venous air embolism: a rare complication of esophageal dilation by rendezvous.

    Science.gov (United States)

    Zald, Philip B; Andersen, Peter E

    2011-03-01

    Esophageal dilation by rendezvous is a useful technique for the treatment of complicated esophageal strictures. We present a case of a 74-year-old man with chronic dysphagia caused by a complete cervical esophageal stricture that developed after external beam radiotherapy for treatment of papillary thyroid carcinoma. During attempted dilation using the rendezvous technique, the patient suffered a fatal pulmonary air embolism. The technique of esophageal dilation by rendezvous, complications, and risk factors for development of venous air embolism are discussed. To the best of our knowledge, this is the first report in the literature of fatal venous air embolism after dilation by rendezvous. Copyright © 2009 Wiley Periodicals, Inc.

  15. Validation of a novel venous duplex ultrasound objective structured assessment of technical skills for the assessment of venous reflux.

    Science.gov (United States)

    Jaffer, Usman; Normahani, Pasha; Lackenby, Kimberly; Aslam, Mohammed; Standfield, Nigel J

    2015-01-01

    Duplex ultrasound measurement of reflux time is central to the diagnosis of venous incompetence. We have developed an assessment tool for Duplex measurement of venous reflux for both simulator and patient-based training. A novel assessment tool, Venous Duplex Ultrasound Assessment of Technical Skills (V-DUOSATS), was developed. A modified DUOSATS was used for simulator training. Participants of varying skill level were invited to viewed an instructional video and were allowed ample time to familiarize with the Duplex equipment. Attempts made by the participants were recorded and independently assessed by 3 expert assessors and 5 novice assessors using the modified V-DUOSATS. "Global" assessment was also done by expert assessors on a 4-point Likert scale. Content, construct, and concurrent validities as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. Receiver operator characteristic analysis-established cut points of 19/22 and 21/30 were most appropriate for simulator and patient-based assessment, respectively. We have validated a novel assessment tool for Duplex venous reflux measurement. Further work is required to establish transference validity of simulator training to improve skill in scanning patients. We have developed and validated V-DUOSATS for simulator training. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Endovascular therapy for chronic cerebrospinal venous insufficiency in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Marc A. Lazzaro

    2011-07-01

    Full Text Available Recent reports have emerged suggesting that multiple sclerosis (MS may be due to abnormal venous outflow from the central nervous system, termed Chronic Cerebrospinal Venous Insufficiency (CCSVI. These reports have generated strong interest and controversy over the prospect of a treatable cause of this chronic debilitating disease. This review aims to describe the proposed association between CCSVI and MS, summarize the current data, and discuss the role of endovascular therapy and the need for rigorous randomized clinical trials to evaluate this association and treatment.

  17. Resuscitation by hyperbaric exposure from a venous gas emboli following laparoscopic surgery

    DEFF Research Database (Denmark)

    Kjeld, Thomas; Hansen, Egon G; Holler, Nana G

    2012-01-01

    Venous gas embolism is common after laparoscopic surgery but is only rarely of clinical relevance. We present a 52 year old woman undergoing laparoscopic treatment for liver cysts, who also underwent cholecystectomy. She was successfully extubated. However, after a few minutes she developed cardiac......, could have contributed to the formation of the intravascular gas emboli. We conclude that persistent resuscitation followed by hyperbaric oxygen treatment after venous gas emboli contributed to the elimination of intravascular bubbles and the favourable outcome for the patient....... arrest due to a venous carbon dioxide (CO2) embolism as identified by transthoracic echocardiography and aspiration of approximately 7 ml of gas from a central venous catheter. She was resuscitated and subsequently treated with hyperbaric oxygen to reduce the size of remaining gas bubbles. Subsequently...

  18. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  19. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    Directory of Open Access Journals (Sweden)

    Masato Kimura

    2017-01-01

    Full Text Available Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  20. Internal jugular vein thrombosis associated with venous hypoplasia and protein S deficiency revealed by ultrasonography.

    Science.gov (United States)

    Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung

    2011-12-01

    A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.

  1. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  2. Venous hemodynamic changes in lower limb venous disease

    DEFF Research Database (Denmark)

    Lee, Byung Boong; Nicolaides, Andrew N; Myers, Kenneth

    2016-01-01

    ). Their aim was to confirm or dispel long-held hemodynamic principles and to provide a comprehensive review of venous hemodynamic concepts underlying the pathophysiology of lower limb venous disorders, their usefulness for investigating patients and the relevant hemodynamic changes associated with various...... forms of treatment. Chapter 1 is devoted to basic hemodynamic concepts and normal venous physiology. Chapter 2 presents the mechanism and magnitude of hemodynamic changes in acute deep vein thrombosis indicating their pathophysiological and clinical significance. Chapter 3 describes the hemodynamic...... changes that occur in different classes of chronic venous disease and their relation to the anatomic extent of disease in the macrocirculation and microcirculation. The next four chapters (Chapters 4-7) describe the hemodynamic changes resulting from treatment by compression using different materials...

  3. Diagnosis of deep venous thrombosis by radioisotopic phlebography

    International Nuclear Information System (INIS)

    Araujo, Antonio Luiz de

    1993-01-01

    The author studied 20 patients with deep venous thrombosis of members (one of them attacked on both arms), from various etiologies, by mean radioisotopic phlebography, in the Vascular Diseases, Radiology and Nuclear Medicine Services of Army Central Hospital (Rio de Janeiro, Brazil) from january 1988 to june 1990. The years old was 18 to 72. The cause most frequency of deep venous thrombosis was idiopathic (seven cases 33.3%). The presence of clot by radionuclide marker in all cases, 16 observations (76.2%) in the lower members and five in the upper extremities (23.9%); 17 cases (85%) also were a conventional venography and his images were confirmed. The diagnostic of deep venous thrombosis from 99m T c MAA (macro aggregate of albumin tagged with technetium) should always de complemented by pulmonary mapping, tracking possible silent emboli. Permit as well repetitions evolutionary until daily and using in patients with history of allergy to radiologic contrast because has not complication. (author)

  4. [Technical criteria of central venous catheters: Anaesthesiologist/intensivist and pharmacist opinions].

    Science.gov (United States)

    Novais, T; Cabelguenne, D; Jolivet, F; Nouvel, M; Wallet, F; Piriou, V

    2015-11-01

    The lack of technical information from suppliers and from the literature, a wide variety of features and the absence of medical device reference document explain the difficulty for medical and pharmaceutical staffs to choose a central venous catheter (CVC). The aim of this study was to establish the specifications to choose a CVC according to the clinician needs. An analysis of suppliers' technical documentation and a literature review was performed to identify criteria and to collect them in a questionnaire to conduct semi-structured interviews between 1 pharmacist and 5 anaesthesiologists/intensivists. With these interviews, the technical criteria were classified according to their importance in 3 levels. Thirteen technical criteria were identified after reading the technical documents and the literature. Among them, 8 were classified as "essential criteria" (level I) by the physicians: J-shaped guide, one clamp on each way, identified lumen, radiopacity, graduation every centimeter by 5 to 20 cm from the distal extremity, a length of 15 to 25 cm, a single-lumen catheter with a 14 to 16G way and a three-lumen catheter with 14 to 18G way. Finally, three criteria were classified as "intermediate criteria" (level II) and two as "optional criteria" (level III). This collaborative approach allowed to reference new medical devices according to the clinicians needs. These CVC are a mean to respect guidelines for physicians and nurses and to secure the patient's care. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Antibiotic-Impregnated Central Venous Catheters Do Not Change Antibiotic Resistance Patterns.

    Science.gov (United States)

    Turnbull, Isaiah R; Buckman, Sara A; Horn, Christopher B; Bochicchio, Grant V; Mazuski, John E

    2018-01-01

    Antibiotic-impregnated central venous catheters (CVCs) decrease the incidence of infection in high-risk patients. However, use of these catheters carries the hypothetical risk of inducing antibiotic resistance. We hypothesized that routine use of minocycline and rifampin-impregnated catheters (MR-CVC) in a single intensive care unit (ICU) would change the resistance profile for Staphylococcus aureus. We reviewed antibiotic susceptibilities of S. aureus isolates obtained from blood cultures in a large urban teaching hospital from 2002-2015. Resistance patterns were compared before and after implementation of MR-CVC use in the surgical ICU (SICU) in August 2006. We also compared resistance patterns of S. aureus obtained in other ICUs and in non-ICU patients, in whom MR-CVCs were not used. Data for rifampin, oxacillin, and clindamycin were available for 9,703 cultures; tetracycline resistance data were available for 4,627 cultures. After implementation of MR-CVC use in the SICU, rifampin resistance remained unchanged, with rates the same as in other ICU and non-ICU populations (3%). After six years of use of MR-CVCs in the SICU, the rate of tetracycline resistance was unchanged in all facilities (1%-3%). The use of MR-CVCs was not associated with any change in S. aureus oxacillin-resistance rates in the SICU (66% vs. 60%). However, there was a significant decrease in S. aureus clindamycin resistance (59% vs. 34%; p resistance of S. aureus isolates to rifampin or tetracyclines.

  6. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  7. Progressive central hypovolaemia in man--resulting in a vasovagal syncope?

    DEFF Research Database (Denmark)

    Sander-Jensen, K; Mehlsen, J; Secher, N H

    1987-01-01

    Hypotensive functional haemorrhage induced by venous pooling of blood in the legs has been reported to be characterized by a vasovagal reaction. In the present study these observations were extended by determination of the hormonal profile developed during progressive central hypovolaemia...... and an emotionally induced vasovagal syncope. In six subjects venous pooling resulted in normotensive central hypovolaemia, in one subject hypotensive central hypovolaemia was induced, and one subject experienced an emotionally induced vasovagal syncope. During normotensive central hypovolaemia heart rate increased...... from 58 +/- 4 to 76 +/- 4 beats min-1 (P less than 0.05) and cardiac output fell from 6.1 +/- 0.4 to 4.1 +/- 0.2 1 min-1. Pulse pressure and central venous pressure decreased from 64 +/- 4 to 53 +/- 4 mmHg, and from 8 +/- 2 to 3 +/- 2 mmHg, respectively. Adrenaline and noradrenaline increased from 87...

  8. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  9. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, M.P.; van Oosten, B.W.; de Graaf, W.L.; Seewann, A.M.; Bot, J.C.J.; van den Berg, R.; Uitdehaag, B.M.J.; Polman, C.H.; Barkhof, F.

    2011-01-01

    Background: Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the

  10. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, Mike P.; van Oosten, Bob W.; de Graaf, Wolter L.; Seewann, Alexandra; Bot, Joseph C. J.; van den Berg, René; Uitdehaag, Bernard M. J.; Polman, Chris H.; Barkhof, Frederik

    2011-01-01

    Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the intracerebral

  11. Analysis of the vertebral venous system in relation to cerebral venous drainage on MR angiography

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Sohn, Chul Ho; Kim, Gab Chul; Kim, Yong Sun

    2004-01-01

    In the supine position, cerebral venous drainage occurs primarily through the internal jugular veins, as seen on venous phase cerebral angiography. However, in the erect position, the vertebral venous system represents the major alternative pathway of cerebral venous drainage, while outflow through the internal jugular veins is absent or negligible. The purpose of this study is to evaluate the vertebral venous system and its relationship between the surrounding venous structures using magnetic resonance angiography (MRA) in the case of subjects in the supine position. We retrospectively reviewed the results of 65 patients (M:F = 31: 34, mean age 61.6 years) who underwent multi-phase contrast-enhanced carotid MRA. The imaging studies were performed using a 3.0 T MR unit (TR: 5.2, TE: 1.1, FA: 20, 3.8 thickness, EC: 1). We analyzed the appearance and extent of the vertebral venous system (vertebral venous plexus and vertebral artery venous plexus) and the internal jugular vein on the venous phase images. We also evaluated the main drainage pattern of the cerebral venous drainage and the drainage pattern of the vertebral venous system. The visualized vertebral venous system was defined as either poor, vertebral venous plexus dominant, vertebral artery venous plexus dominant or mixed. In the vertebral venous system, the vertebral artery venous plexus was visualized in 54 cases (83%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 39 cases (72%) and asymmetrical in 15 cases (28%). The extent of the visualized vertebral artery venous plexus was partial in 26 cases (48%) and complete in 28 cases (52%). The vertebral venous plexus was visualized in 62 cases (95%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 43 cases (69%) and asymmetrical in 19 cases (31%). The extent of the visualized vertebral artery venous plexus was partial in 35 cases (56%) and complete in 27 cases (44%). The appearance of the

  12. Risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation.

    Science.gov (United States)

    Atchison, Christie M; Amankwah, Ernest; Wilhelm, Jean; Arlikar, Shilpa; Branchford, Brian R; Stock, Arabela; Streiff, Michael; Takemoto, Clifford; Ayala, Irmel; Everett, Allen; Stapleton, Gary; Jacobs, Marshall L; Jacobs, Jeffrey P; Goldenberg, Neil A

    2018-02-01

    Paediatric hospital-associated venous thromboembolism is a leading quality and safety concern at children's hospitals. The aim of this study was to determine risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation. We conducted a retrospective, case-control study of children admitted to the cardiovascular intensive care unit at Johns Hopkins All Children's Hospital (St. Petersburg, Florida, United States of America) from 2006 to 2013. Hospital-associated venous thromboembolism cases were identified based on ICD-9 discharge codes and validated using radiological record review. We randomly selected two contemporaneous cardiovascular intensive care unit controls without hospital-associated venous thromboembolism for each hospital-associated venous thromboembolism case, and limited the study population to patients who had undergone cardiothoracic surgery or therapeutic cardiac catheterisation. Odds ratios and 95% confidence intervals for associations between putative risk factors and hospital-associated venous thromboembolism were determined using univariate and multivariate logistic regression. Among 2718 admissions to the cardiovascular intensive care unit during the study period, 65 met the criteria for hospital-associated venous thromboembolism (occurrence rate, 2%). Restriction to cases and controls having undergone the procedures of interest yielded a final study population of 57 hospital-associated venous thromboembolism cases and 76 controls. In a multiple logistic regression model, major infection (odds ratio=5.77, 95% confidence interval=1.06-31.4), age ⩽1 year (odds ratio=6.75, 95% confidence interval=1.13-160), and central venous catheterisation (odds ratio=7.36, 95% confidence interval=1.13-47.8) were found to be statistically significant independent risk factors for hospital-associated venous thromboembolism in these children. Patients with all three

  13. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  14. CT findings of posterior fossa venous angiomas

    International Nuclear Information System (INIS)

    Satoh, Toru; Kinugasa, Kazushi; Nishimoto, Akira; Nishimoto, Ken.

    1986-01-01

    Three cases of posterior fossa venous angiomas were reported, with some comments on the CT findings. Case 1: A 53-year-old woman was admitted for the further examination of a viral meningitis which had appeared three months before. Neurological examination revealed no abnormality. Vertebral angiography, however, demonstrated numerous fine medullary veins, with an enlarged intraparenchymal draining vein, in the right cerebellum; they drained into the petrosal vein, which was characteristic of venous angioma. On the plain CT, part of the draining vein was identified as a slightly high-density node. A curvilinear draining vein was demonstrated by the enhanced CT. Case 2: A 29-year-old man was admitted complaining of headache, vomiting, and atxia. Neurological examination disclosed truncal ataxia. The enhanced CT demonstrated two distinct nodules on the anterior border of the hematoma in the deep median cerebellum, probably corresponding to the draining veins. On the angiogram, a venous angioma was found in the bilateral cerebellum; it drained into the precentral cerebellar veins and ultimately joined the straight sinus via the precentro-vermo-rectal vein. Case 3: A 4-year-old boy was admitted suffering from headache, vomiting, and ataxia. Neurological examination disclosed a co-ordination disturbance of the left side. The enhanced CT demonstrated a curvilinear structure inside the hematoma. Angiography showed a venous angioma in the left cerebellum which drained into the petrosal vein. Computerized angiotomography delineated the characteristic venous structure on the angiogram as many fine, high-density lines (medullary veins) converging to a large intraparenchymal linear structure (central medullary vein) and then to a superficial cortical vein. In all cases, large intraparenchymal draining veins were identified by the conventional CT. (J.P.N.)

  15. Risk factors for venous port migration in a single institute in Taiwan.

    Science.gov (United States)

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-14

    An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.

  16. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices

  17. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  18. Colonization of a Central Venous Catheter by the Hyaline Fungus Fusarium solani Species Complex: A Case Report and SEM Imaging

    Directory of Open Access Journals (Sweden)

    Alberto Colombo

    2013-01-01

    Full Text Available The incidence of opportunistic infections by filamentous fungi is increasing partly due to the widespread use of central venous catheters (CVC, indwelling medical devices, and antineoplastic/immunosuppressive drugs. The case of a 13-year-old boy under treatment for acute lymphoblastic leukemia is presented. The boy was readmitted to the Pediatric Ward for intermittent fever of unknown origin. Results of blood cultures drawn from peripheral venous sites or through the CVC were compared. CVC-derived bottles (but not those from peripheral veins yielded hyaline fungi that, based on morphology, were identified as belonging to the Fusarium solani species complex. Gene amplification and direct sequencing of the fungal ITS1 rRNA region and the EF-1alpha gene confirmed the isolate as belonging to the Fusarium solani species complex. Portions of the CVC were analyzed by scanning electron microscopy. Fungi mycelia with long protruding hyphae were seen into the lumen. The firm adhesion of the fungal formation to the inner surface of the catheter was evident. In the absence of systemic infection, catheter removal and prophylactic voriconazole therapy were followed by disappearance of febrile events and recovery. Thus, indwelling catheters are prone to contamination by environmental fungi.

  19. Risk Factors Related to Peripherally Inserted Central Venous Catheter Nonselective Removal in Neonates

    Directory of Open Access Journals (Sweden)

    Xiaohe Yu

    2018-01-01

    Full Text Available We aimed to investigate the incidence and risk factors associated with nonselective removal of peripherally inserted central venous catheter (PICC in neonates. In this prospective cohort study, neonates who underwent PICC placement at neonatal intensive care units (NICUs in China from October 2012 to November 2015 were included. The patient demographics, catheter characteristics, catheter duration, PICC insertion site, indication for PICC insertion, infuscate composition, PICC tip location, and catheter complications were recorded in a computerized database. Risk factors for nonselective removal were analyzed. A total of 497 PICCs were placed in 496 neonates. Nonselective removal occurred in 9.3% of PICCs during 10,540 catheter-days (4.6 nonselective removals per 1,000 catheter-days. These included occlusion (3%, infection (1.4%, leakage (2.0%, phlebitis (0.6%, displacement (1%, pleural effusion(0.6%, and breaks (0.6%. Noncentral tip position was independently associated with an increased risk of nonselective removal (odds ratio 2.621; 95% confidence interval, 1.258-5.461 after adjusting for gestational age, sex, birth weight, and PICC dwell time. No significant differences in the rate of complications occurred between silastic and polyurethane PICC or different insertion sites. Noncentral PICC tip position was the only independent risk factor for nonselective removal of PICC.

  20. Successful Retrieval of a Dismembered Central Venous Catheter Stuck to the Right Pulmonary Artery Using a Stepwise Approach

    Directory of Open Access Journals (Sweden)

    Keisuke Nakabayashi

    2016-01-01

    Full Text Available Recent advances in anticancer chemotherapy have resulted in an increase in the number of patients requiring a central venous port catheter, and the incidence of catheter pinch-off syndrome has been increasing. Catheter pinch-off syndrome is a rare and unusual complication. It is difficult to retrieve dislodged catheters from the pulmonary artery, especially if the catheter is stuck to the peripheral pulmonary artery. We herein describe the successful removal of a catheter stuck in the pulmonary artery with a stepwise approach. First, a pigtail catheter was used to tug the dislodged catheter in order to free the unilateral end. Then, a gooseneck snare was used to catch and pull the catheter out of the patient. The key to success is to free the end of the catheter.

  1. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    Science.gov (United States)

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  2. Method for determining the schematic presentation for the cortical sulci and venous system

    International Nuclear Information System (INIS)

    Tatemichi, Nobuhiro; Nakano, Hirotake; Inoue, Yoshiharu.

    1994-01-01

    To realize the corticogram of major sulci and venous system, two different image modalities must be superposed with a minimum error : MRI, MRA and X-Ray angiography. The precise schema of cortical sulci have to become possible with the aid of the IR method of MRI that could clearly identify the sulcal system of the outer and internal surface of the hemisphere. The correspondence of the major venous system of MRI with that of angiography was carried out using several skin markers, bone structures and a deep major venous system. This corticogram was used by the neurosurgeons of the hospital for the electrode placement, the topographical identification of the cortical paroxysms and epilepsy surgery. The best argument for the accuracy of sulcal and venous schema could be offered by somato-sensory evoked potential identifying the central sulcus on the corticogram. (author)

  3. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    International Nuclear Information System (INIS)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub; Yoon, Ji Young

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16±0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51±0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52±0.25, while in 21 non-traumatic patients it was 1.15±0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT

  4. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub [Dongguk Univ. College of Medicine, Pohang (Korea, Republic of); Yoon, Ji Young [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16{+-}0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51{+-}0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52{+-}0.25, while in 21 non-traumatic patients it was 1.15{+-}0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT.

  5. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  6. Mensuração de pressão venosa central por meio de cateteres venosos central e periférico: comparação entre os valores obtidos em cães e elaboração de índice de correção Measurement of central venous Pressure by mean of central and peripheric catheters: comparison among the obtained vallues in dogs and elaboration of a correction index

    Directory of Open Access Journals (Sweden)

    Eduardo Santiago Ventura de Aguiar

    2004-12-01

    Full Text Available A Pressão Venosa Central (PVC é a pressão de retorno do sangue ao lado direito do coração e é um importante parâmetro a ser aferido em numerosas situações clínicas, cirúrgicas e experimentais. Para sua realização, utiliza-se um Cateter Venoso Central (CVC aplicado na veia jugular. Em virtude de este ser um aparato intravenoso de alto custo, optou-se por testar a validade de se aferir a PVC com um Cateter Venoso Periférico (CVP aplicado à mesma veia, o qual apresenta custo reduzido. Como resultado, a medida da PVC, tomada com o CVC, deve sofrer um índice de redução, chegando-se, assim, ao valor da PVC que seria obtido com o uso do CVC. Os resultados deste estudo permitem concluir que o CVP é apropriado para a aferição da PVC em cães.The Central Venous Pressure (CVP is a very important pattern for monitorization in many clinical, surgical and experimental procedures, and it reflects the blood pressure that returns to the right heart side. For its measurement a Central Venous Catheter (CVC must be used inside the jugular vein. Because of the high cost of the CVC, an option was taken to measure the CVP with a Peripheric Venous Catheter (PVC inside the jugular vein, with low cost. The CVP measure obtained with the PVC must be subtracted to a reduction index, in this way the measure would correspond to the ones done with the CVC. This study alouds to conclude that the PVC is adequate for CVP measurement in dogs.

  7. Evaluation of mupirocin ointment in control of central venous catheter related infections: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Rezaei J

    2009-09-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Central venous catheter (CVC related infections are important complications of cathter application. This study assessed the usefulness of mupirocin in prevention and control of these infections."n"nMethods: In this randomized clinical trial, consecutive surgical patients requiring central venous catheter (for more than 2 days in Amir-Alam Hospital from 2006-2008 were enrolled. Patients were divided in two groups; in "case group" patients received topical mupirocin 2% every 48 hours at the time of insertion of catheter and dressing change and for "control group" mupirocin was not used. All of the patients received chlorhexidine and enoxoparin as complementary treatments. Two groups were comparable in regard of age, sex and risk factors."n"nResults: One hundred eighteen patients enrolled in the study (57 in case and 61 in control group completed the study. 84 catheters in case group and 88 catheters in control group were inserted. The catheters in 90% of patients were inserted in jugular vein. At the end of study 29(16.8% patients (16 in control versus 13 in case group had catheter colonization (p=NS. Catheter related bloodstream infection was observed in 16(9.3% patients (6 in

  8. Measurement of cardiac index by transpulmonary thermodilution using an implanted central venous access port: a prospective study in patients scheduled for oncologic high-risk surgery.

    Science.gov (United States)

    Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire

    2014-01-01

    Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (-0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. clinicaltrials.gov NCT02063009.

  9. The alternative sigma factor sigma B of Staphylococcus aureus modulates virulence in experimental central venous catheter-related infections.

    Science.gov (United States)

    Lorenz, Udo; Hüttinger, Christian; Schäfer, Tina; Ziebuhr, Wilma; Thiede, Arnulf; Hacker, Jörg; Engelmann, Susanne; Hecker, Michael; Ohlsen, Knut

    2008-03-01

    The impact of the alternative sigma factor sigma B (SigB) on pathogenesis of Staphylococcus aureus is not conclusively clarified. In this study, a central venous catheter (CVC) related model of multiorgan infection was used to investigate the role of SigB for the pathogenesis of S. aureus infections and biofilm formation in vivo. Analysis of two SigB-positive wild-type strains and their isogenic mutants revealed uniformly that the wild-type was significantly more virulent than the SigB-deficient mutant. The observed difference in virulence was apparently not linked to the capability of the strains to form biofilms in vivo since wild-type and mutant strains were able to produce biofilm layers inside of the catheter. The data strongly indicate that the alternative sigma factor SigB plays a role in CVC-associated infections caused by S. aureus.

  10. Venous Ulcers

    Science.gov (United States)

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  11. Pacientes assintomáticos apresentam infecção relacionada ao cateter venoso utilizado para terapia nutricional parenteral Asymptomatic patients present infection related to the central venous catheter used for total parenteral nutrition

    Directory of Open Access Journals (Sweden)

    Juliana Deh Carvalho Machado

    2009-12-01

    Full Text Available OBJETIVO: Avaliar a freqüência de infecção relacionada ao cateter venoso central em pacientes submetidos a terapia nutricional parenteral. MÉTODOS: Foram analisados os cateteres venosos centrais de pacientes em terapia nutricional parenteral que tiveram a indicação de retirada do cateter venoso central por infecção, alta hospitalar, ou trombose. Os pacientes com infecção foram denominados de Grupo 1 e os demais de Grupo 2. RESULTADOS: Não houve diferença estatisticamente significante quanto ao estado nutricional dos 18 pacientes analisados. Foram analisados 28 cateteres e destes 68% estavam infectados, sendo 72% do Grupo 1 e 28% do Grupo 2 (assintomáticos. No Grupo 1, houve infecção sistêmica em 70% dos casos, já no Grupo 2 a hemocultura foi positiva em 17% dos casos. A colonização por Staphylococcus sp. ocorreu em 48% dos casos, seguida de Candida sp. (21%, Enterococcus faecalis (16%, Pseudomonas aerurginosa (10% e Proteus sp.(5%. CONCLUSÃO: A contaminação de cateter venoso central utilizado para terapia nutricional parenteral é freqüente. Mesmo pacientes assintomáticos recebendo nutrição parenteral têm uma incidência maior de infecção por Candida sp. Portanto é necessária a criação de barreiras que impeçam a colonização destes cateteres venosos centrais, a fim de diminuir a morbimortalidade de pacientes dependentes deste tipo de terapia.OBJECTIVE: The aim of this study was to evaluate the frequency of central venous catheter-related infections in hospitalized patients receiving total parenteral nutrition. METHODS: Central venous catheters were analyzed immediately after removal due to infection, hospital discharge or thrombosis. The patients with catheter-related infection were named Group 1 and the other patients were named Group 2. RESULTS: Eighteen patients were studied. There was no statistically significant difference in nutritional status between the two groups. A total of 28 catheters were analyzed

  12. Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.

    Science.gov (United States)

    Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H

    2018-03-14

    The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.

  13. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  14. Medical management of venous ulcers.

    Science.gov (United States)

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Diagnosis of venous disorders

    International Nuclear Information System (INIS)

    Minar, E.

    1993-01-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.) [de

  16. Brain venous pathologies: MRI findings

    International Nuclear Information System (INIS)

    Salvatico, Rosana; Gonzalez, Alejandro; Yanez, Paulina; Romero, Carlos; Trejo, Mariano; Lambre, Hector

    2006-01-01

    Purpose: To describe MRI findings of the different brain venous pathologies. Material and Methods: Between January 2002 and March 2004, 18 patients were studied 10 males and 8 females between 6 and 63 years old; with different brain venous pathologies. In all cases brain MRI were performed including morphological sequences with and without gadolinium injection and angiographic venous sequences. Results: 10 venous occlusions were found, 6 venous angiomas, and 2 presented varices secondary to arteriovenous dural fistula. Conclusion: Brain venous pathologies can appear in many different clinical contexts, with different prognosis and treatment. In all the cases brain MRI was the best imaging study to disclose typical morphologic abnormalities. (author) [es

  17. Cerebral venous angiomas

    International Nuclear Information System (INIS)

    Agnoli, A.L.; Hildebrandt, G.

    1985-01-01

    Clinical symptoms and radiological signs in 15 patients with cerebral venous malformations are presented and the diagnostic problems discussed. The circulation time in combination with cerebral malformations and angiomas of the scalp are described. CT findings in cases of venous malformations of the brain stem are evaluated. Spot-like enhancement, as well as sharply demarcated round shaped enhancement are characteristic for venous angiomas. Cavernous angiomas usually present as homogenous or inhomogenous round shaped enhanced areas. (Author)

  18. Venous ulcers -- self-care

    Science.gov (United States)

    ... surgery to improve blood flow through your veins. Prevention If you are at risk for venous ulcers, take the steps listed above under Wound Care. ... weight if you are overweight. Manage your blood pressure and cholesterol levels. ... Venous leg ulcers - self-care; Venous insufficiency ulcers - self-care; Stasis ...

  19. Management of venous hypertension following arteriovenous fistula creation for hemodialysis access

    Directory of Open Access Journals (Sweden)

    Varun Mittal

    2016-01-01

    Full Text Available Introduction: Venous hypertension (VH is a distressing complication following the creation of arteriovenous fistula (AVF. The aim of management is to relieve edema with preservation of AVF. Extensive edema increases surgical morbidity with the loss of hemodialysis access. We present our experience in management of VH. Methods: A retrospective study was conducted on 37 patients with VH managed between July 2005 to May 2014. Patient demographics, evaluation, and procedures performed were noted. A successful outcome of management with surgical ligation (SL, angioembolization (AE, balloon dilatation (BD or endovascular stent (EVS was defined by immediate disappearance of thrill and murmur with resolution of edema in the next 48-72 h, no demonstrable flow during check angiogram and resolution of edema with preservation of AVF respectively. Results: All 8 distal AVF had peripheral venous stenosis and were managed with SL in 7 and BD in one patient. In 29 proximal AVF, central and peripheral venous stenosis was present in 16 and 13 patients respectively. SL, AE, BD, and BD with EVS were done in 18, 5, 4, and 3 patients, respectively. All patients had a successful outcome. SL was associated with wound related complications in 11 (29.73 % patients. A total of 7 AVF were salvaged. One had restenosis after BD and was managed with AE. BD, EVS, and AE had no associated morbidity. Conclusions: Management of central and peripheral venous stenosis with VH should be individualized and in selected cases it seems preferable to secure a new access in another limb and close the native AVF in edematous limb for better overall outcome.

  20. CSF Venous Fistulas in Spontaneous Intracranial Hypotension: Imaging Characteristics on Dynamic and CT Myelography.

    Science.gov (United States)

    Kranz, Peter G; Amrhein, Timothy J; Gray, Linda

    2017-12-01

    The objective of this study is to describe the anatomic and imaging features of CSF venous fistulas, which are a recently reported cause of spontaneous intracranial hypotension (SIH). We retrospectively reviewed the records of patients with SIH caused by CSF venous fistulas who received treatment at our institution. The anatomic details of each fistula were recorded. Attenuation of the veins involved by the fistula was compared with that of adjacent control veins on CT myelography (CTM). Visibility of the CSF venous fistula on CTM and a modified conventional myelography technique we refer to as dynamic myelography was also compared. Twenty-two cases of CSF venous fistula were identified. The fistulas were located between T4 and L1. Ninety percent occurred without a concurrent epidural CSF leak. In most cases (82%), the CSF venous fistula originated from a nerve root sleeve diverticulum. On CTM, the abnormal veins associated with the CSF venous fistula were seen in a paravertebral location in 45% of cases, centrally within the epidural venous plexus in 32%, and lateral to the spine in 23%. Differences in attenuation between the fistula veins and the control veins was highly statistically significant (p CSF venous fistulas are an important cause of SIH that can be detected on both CTM and dynamic myelograph y and may occur without an epidural CSF leak. Familiarity with the imaging characteristics of these lesions is critical to providing appropriate treatment to patients with SIH.

  1. [Thrombosis and obstruction associated with central venous lines. Incidence and risk factors].

    Science.gov (United States)

    Vivanco Allende, A; Rey Galán, C; Rodríguez de la Rúa, M V; Alvarez García, F; Medina Villanueva, A; Concha Torre, A; Mayordomo Colunga, J; Martínez Camblor, P

    2013-09-01

    To analyse the incidence of thrombosis and obstruction associated with central venous lines (CVL) inserted in critically ill children, and to determine their risk factors. Prospective observational study in a Pediatric Intensive Care Unit in a University Hospital. An analysis was made of 825 CVL placed in 546 patients. Age, gender, weight, type of catheter (lines, size, and brand), final location of the catheter, mechanical ventilation, type of sedation and analgesia used, initial failure by the doctor to perform CVL catheterization, number of attempts, CVL indication, admission diagnosis, emergency or scheduled procedure, and delayed mechanical complications (DMC). Risk factors for these complications were determined by a multiple regression analysis. A total of 52 cases of DMC, 42 cases of obstruction, and 10 of thrombosis were registered. Obstruction and thrombosis rates were 4.96 and 1.18 per 100 CVL, respectively. The only risk factor independently linked to obstruction was the duration of the CVL (OR 1.05; 95% CI; 1.00-1.10). The number of lines with thrombosis (OR 4.88; 95% CI; 1.26-18.0), as well as parenteral nutrition (OR 4.17; 95% CI; 1.06-16.31) was statistically significant according to bivariate analysis. However, no risk factors for thrombosis were found in the multivariate analysis. Obstruction and thrombosis of CVL inserted in a Pediatric Intensive Care Unit are relatively common complications. CVL duration is an independent risk factor for any line obstruction. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  2. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series.

    Science.gov (United States)

    Docktor, B L; Sadler, D J; Gray, R R; Saliken, J C; So, C B

    1999-08-01

    The objective was to examine the success and immediate complication rates in a large series of radiologically placed tunneled central venous catheters. We prospectively recorded the success and immediate complication rates in 880 consecutive radiologically placed tunneled central venous catheters. We also recorded the indication for placement, the success of placement, the number of passes required, and whether a double- or single-wall puncture occurred. Hemodialysis was the most common indication for long-term venous access. Venous access was successful in all patients, and catheter placement was successful in 99.4% of patients, with only five failed placements. All patients in whom placement was initially unsuccessful underwent successful placement the same day. All catheters were placed using real-time sonographic guidance. Most were placed in an internal jugular vein, with 87.4% requiring only a single needle pass. The immediate complication rate was only 4.0%, and no major complications occurred. To our knowledge, this series is the largest for which the immediate complication and success rates for radiologically placed central venous catheters have been reported. Our results suggest that radiologic placement of tunneled central venous catheters is a safe and effective alternative to surgery.

  3. Models of the venous system

    DEFF Research Database (Denmark)

    Mehlsen, J

    2000-01-01

    Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models of the v......Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models...... of the venous system require at least three elements: a resistor, a capacitor and an inductor, with the latter being of more importance in the venous than in the arterial system. Non-linearities must be considered in pressure/flow relations in the small venules, during venous collapse, or low flow conditions...

  4. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  5. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters

    DEFF Research Database (Denmark)

    Partovi-Deilami, Kohyar; Nielsen, Jesper K.; Møller, Ann M.

    2016-01-01

    operated by nurse anesthetists for these patients. This prospective observational study with a pre/post design focused on inpatients with DIVA referred for PVC placement, a service provided by nurse anesthetists in most Scandinavian hospitals. The rate of success, procedure time, number of skin punctures......) with ultrasound. Procedure time was reduced from 20 to 10 minutes, discomfort was unchanged, and the median number of skin punctures decreased from 3 to 2. The incidence of central venous catheter placement dropped from 34% to 7%. Implementation of a training program and a mobile service in which nurse......, discomfort, catheter size, location, and incidence of central venous catheter placement are reported before and after implementation of a training program and a mobile service using ultrasound to place difficult-to-place PVCs. The success rate increased from 0% (0 of 33 patients) to 83% (58 of 70 patients...

  6. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Schummer, C.; Sakr, Y.; Reinhart, K. [Jena Univ. (Germany). Klinik fuer Anaestesiologie und Intensivtherapie; Steenbeck, J. [Jena Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Gugel, M. [Zentralklinik Bad Berka (Germany). Klinik fuer Anaesthesiologie und Intensivtherapie; Schummer, W. [SRH Zentralklinikum Suhl (Germany). Dept. of Anaesthesiology and Intensive Care Medicine

    2010-01-15

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  7. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    International Nuclear Information System (INIS)

    Schummer, C.; Sakr, Y.; Reinhart, K.; Steenbeck, J.; Gugel, M.; Schummer, W.

    2010-01-01

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  8. Placement of a Retrievable Guenther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis

    International Nuclear Information System (INIS)

    Nadkarni, Sanjay; Macdonald, Sumaira; Cleveland, Trevor J.; Gaines, Peter A.

    2002-01-01

    A retrievable Guenther Tulip caval filter(William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances

  9. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. The risk of bloodstream infection associated with peripherally inserted central catheters compared with central venous catheters in adults: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; O'Horo, John C; Rogers, Mary A M; Maki, Dennis G; Safdar, Nasia

    2013-09-01

    Peripherally inserted central catheters (PICCs) are associated with central line-associated bloodstream infection (CLABSI). The magnitude of this risk relative to central venous catheters (CVCs) is unknown. To compare risk of CLABSI between PICCs and CVCs. MEDLINE, CinAHL, Scopus, EmBASE, and Cochrane CENTRAL were searched. Full-text studies comparing the risk of CLABSI between PICCs and CVCs were included. Studies involving adults 18 years of age or older who underwent insertion of a PICC or a CVC and reported CLABSI were included in our analysis. Studies were evaluated using the Downs and Black scale for risk of bias. Random effects meta-analyses were used to generate summary estimates of CLABSI risk in patients with PICCs versus CVCs. Of 1,185 studies identified, 23 studies involving 57,250 patients met eligibility criteria. Twenty of 23 eligible studies reported the total number of CLABSI episodes in patients with PICCs and CVCs. Pooled meta-analyses of these studies revealed that PICCs were associated with a lower risk of CLABSI than were CVCs (relative risk [RR], 0.62; 95% confidence interval [CI], 0.40-0.94). Statistical heterogeneity prompted subgroup analysis, which demonstrated that CLABSI reduction was greatest in outpatients (RR [95% CI], 0.22 [0.18-0.27]) compared with hospitalized patients who received PICCs (RR [95% CI], 0.73 [0.54-0.98]). Thirteen of the included 23 studies reported CLABSI per catheter-day. Within these studies, PICC-related CLABSI occurred as frequently as CLABSI from CVCs (incidence rate ratio [95% CI], 0.91 [0.46-1.79]). Only 1 randomized trial met inclusion criteria. CLABSI definition and infection prevention strategies were variably reported. Few studies reported infections by catheter-days. Although PICCs are associated with a lower risk of CLABSI than CVCs in outpatients, hospitalized patients may be just as likely to experience CLABSI with PICCs as with CVCs. Consideration of risks and benefits before PICC use in inpatient

  11. Challenges in the Management of Pediatric Central Venous Access Devices in the Community.

    LENUS (Irish Health Repository)

    Wallace, Elaine

    2012-05-25

    Central venous access devices (CVADs) play an essential role in the care of critically ill children. Significant challenges exist for teams in managing CVADs particularly in a community setting. The authors aimed to assess the experience of general practitioners (GPs) caring for children with CVADs. From 200 CVADs inserted in a pediatric hospital in 2009, 50 patients were randomly selected and 44 GPs were forwarded a questionnaire. Twenty (46%) GPs responded. The main reasons (n = 22) for using CVADs were medication administration (n = 11), nutrition (n = 6), and blood sampling (n = 5). Thirteen (65%) GPs had no education in CVAD management and 14 (70%) were unaware of existing guidelines. Those identified by GPs as having primary responsibility for care of CVADs in the community included hospital\\/pediatric teams (n = 9), parents (n = 3), GPs (n = 2), public health nurses (n = 1), and palliative care ("home care") teams (n = 1). The main challenges (n = 15) identified by GPs were lack of education (n = 4), line management difficulties (n = 3), infection risk (n = 3), infrequent exposure to CVADs (n = 3), and poor communication (n = 1). GPs felt that these challenges could be addressed through: education (n = 8), increased manpower and community support (n = 1), and improved communication (n = 1). This study highlights the inconsistency and challenges for GPs surrounding CVAD use in children. Further education and support is necessary to assist GPs in their use particularly when providing end-of-life care for children in the community.

  12. Prophylaxis of Venous Thrombosis.

    Science.gov (United States)

    Goldhaber, Samuel Z.

    2001-06-01

    Mechanical measures such as graduated compression stockings and intermittent compression boots are available for venous thrombosis prophylaxis, but compliance may be limited. Plantar venous pneumatic compression devices have attained widespread acceptance by both patients and nurses because of their comfort and compact size, but their track record for efficacy is poor. Inferior vena cava filters prevent pulmonary embolism, but do not halt the thrombotic process or prevent venous thrombosis. Pharmacologic prophylaxis traditionally has relied upon minidose unfractionated heparin; however, re-examination is warranted in the face of increasingly ill and complex patients. My opinion is that small, fixed doses of once-daily low molecular weight heparin will eventually replace minidose unfractionated heparin as the standard pharmacologic prophylaxis regimen for most surgical and medical patients. Prolongation of prophylaxis after hospital discharge should receive increased emphasis. Most patients being transferred to a skilled nursing facility should receive venous thromboembolism prophylaxis. Similarly, most patients undergoing total hip or knee replacement should receive prolonged preventive regimens, with at least 1 month of anticoagulation. Despite advances, certain aspects of venous thrombosis prophylaxis remain problematic. First, a surprisingly high number of hospitalized patients develop venous thrombosis because of failed (rather than omitted) prophylaxis. Second, many patients in intensive care have a combination of peripheral vascular disease and active bleeding (usually gastrointestinal) that precludes mechanical or pharmacologic prophylaxis. Third, neurosurgical patients undergoing craniotomy for brain tumors suffer a high rate of venous thrombosis and major pulmonary embolism despite the routine use of combined mechanical and pharmacologic prophylaxis. My opinion is that these three areas, in addition to the hospital culture of prophylaxis, should receive

  13. Usefulness of Totally Implantable Central Venous Access Devices in Elderly Patients: A Retrospective Study.

    Science.gov (United States)

    Imaoka, Yuki; Kuranishi, Fumito; Ogawa, Yoshiteru

    2018-01-01

    The need for totally implantable central venous access devices (TICVADs) has increased with increased opportunities in the use of chemotherapy and parenteral nutrition. This study aimed to determine the outcomes of TICVAD implantation and use in patients aged ≥85 years. Between January 2010 and August 2016, 117 patients underwent TICVAD implantation and their records were retrospectively reviewed. Participants were divided into 2 groups (plus-85 and sub-85 groups). Fifty-five patients (47.0%) had solid organ cancer alone; 35 patients (29.9%) had cerebrovascular or cranial nerve disease. The average follow-up period was 201 (2-1,620) days. Major complications were identified in 6 (14.6%) plus-85 patients and 11 (14.5%) sub-85 patients (p = 0.9813). Catheter-related infections developed in 3 plus-85 (7.3%) and 4 sub-85 patients (5.3%; p = 0.6549). There were no significant group differences in hematoma, pneumothorax, occlusion, and removal rates. In plus-85 patients examined just before surgery and a month after surgery, increased rates of serum albumin and Onodera's prognostic nutritional index were observed in 48% (14/39) and 41% (12/39), respectively. The use of TICVADs in the plus-85 group resulted in effective outcomes. The results of this retrospective study support the wider use of TICVADs in patients aged ≥85 years. © 2018 S. Karger AG, Basel.

  14. Factors Associated with Continuous Low Dose Heparin Infusion for Central Venous Catheter Patency in Critically Ill Children Worldwide

    Science.gov (United States)

    Onyeama, Sara-Jane N; Hanson, Sheila J; Dasgupta, Mahua; Hoffmann, Raymond G; Faustino, Edward Vincent S

    2016-01-01

    Objective To identify patient, hospital and central venous catheter (CVC) factors that may influence the use of low dose heparin infusion (LDHI) for CVC patency in critically ill-children. Design Secondary analysis of an international multicenter observational study. Setting 59 Pediatric Intensive Care Units (PICUs) over four study dates in 2012, involving 7 countries. Patients Children less than 18 years of age with a CVC, admitted to a participating unit and enrolled in the completed PROTRACT study were included. All overflow patients were excluded. Interventions None. Measurements and Main Results Of the 2,484 patients in the PROTRACT study, 1,312 patients had a CVC. 507 of those patients used LDHI. The frequency of LDHI was compared across various patient, hospital and CVC factors using chi-squared, Mann-Whitney and Fisher's exact tests. In the multivariate analysis, age was not a significant factor for LDHI use. Patients with pulmonary hypertension had decreased LDHI use while those with active surgical or trauma diagnoses had increased LDHI use. All central CVC insertion sites were more likely to use LDHI when compared to peripherally inserted CVCs. The Asia-Pacific region showed increased LDHI use, along with community hospitals and smaller ICUs (LDHI in critically ill children. Further study is needed to evaluate the efficacy and persistence of LDHI use. PMID:27362853

  15. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    Science.gov (United States)

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Tendon vibration attenuates superficial venous vessel response of the resting limb during static arm exercise

    Directory of Open Access Journals (Sweden)

    Ooue Anna

    2012-11-01

    Full Text Available Abstract Background The superficial vein of the resting limb constricts sympathetically during exercise. Central command is the one of the neural mechanisms that controls the cardiovascular response to exercise. However, it is not clear whether central command contributes to venous vessel response during exercise. Tendon vibration during static elbow flexion causes primary muscle spindle afferents, such that a lower central command is required to achieve a given force without altering muscle force. The purpose of this study was therefore to investigate whether a reduction in central command during static exercise with tendon vibration influences the superficial venous vessel response in the resting limb. Methods Eleven subjects performed static elbow flexion at 35% of maximal voluntary contraction with (EX + VIB and without (EX vibration of the biceps brachii tendon. The heart rate, mean arterial pressure, and rating of perceived exertion (RPE in overall and exercising muscle were measured. The cross-sectional area (CSAvein and blood velocity of the basilic vein in the resting upper arm were assessed by ultrasound, and blood flow (BFvein was calculated using both variables. Results Muscle tension during exercise was similar between EX and EX + VIB. However, RPEs at EX + VIB were lower than those at EX (P P vein in the resting limb at EX decreased during exercise from baseline (P vein at EX + VIB did not change during exercise. CSAvein during exercise at EX was smaller than that at EX + VIB (P vein did not change during the protocol under either condition. The decreases in circulatory response and RPEs during EX + VIB, despite identical muscle tension, showed that activation of central command was less during EX + VIB than during EX. Abolishment of the decrease in CSAvein during exercise at EX + VIB may thus have been caused by a lower level of central command at EX + VIB rather than EX. Conclusion Diminished central command induced by tendon

  17. Thyrocervical artery - jugular fistula following internal jugular venous catheterization

    Directory of Open Access Journals (Sweden)

    P P Zachariah

    2014-01-01

    Full Text Available Arteriovenous fistula (AVF is an anomalous communication between an artery and a vein, caused by an iatrogenic or traumatic etiology. Surgically created upper limb AVF remains the preferred vascular access for patients on maintenance hemodialysis. Nonetheless central vein cannulation for hemodialysis is a common procedure done in patients who need hemodialysis. We incidentally detected a thyrocervical artery - jugular fistula in a patient on maintenance hemodialysis. He underwent a successful intra arterial coil embolization of the feeding vessel. Review of literature has shown that, a thyrocervical artery - internal jugular vein arteriovenous fistula following a central venous catheterization has not been reported so far.

  18. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    Multiple lumen umbilical venous catheters (ML-UVCs) instead of single lumen UVCs (SL-UVCs) may decrease the need for additional venous lines. Although it seems self-evident that ML-UVCs would reduce the need of additional venous lines, the rates of associated complications might be different. To compare the effectiveness and the safety of ML-UVCs versus SL-UVCs in terms of need of additional vascular access, rates of complications, morbidity and mortality in newborn infants. Randomized and quasi-randomized trials were identified by searching the MEDLINE (1966 - February 2005), EMBASE (1980- February 2005), CINAHL (1982 - February 2005), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2004) and Science Direct (subject area: medicine, journal and abstract database; 1967 to February 2005). Literature search also included a manual search of the abstracts of scientific meetings published in Pediatric Research (1990-2004). Additional citations were sought using references in articles retrieved from searches. Subject experts were contacted to identify the unpublished and ongoing studies. Randomized and quasi-randomized controlled clinical trials comparing safety and efficacy of multiple versus single lumen umbilical venous catheter in neonates (both term and preterm) who were in need of umbilical venous catheter insertion for vascular access in first four weeks of life. Each review author performed data extraction independently and differences were resolved by discussion. The following outcomes were determined: total number of additional peripheral intravenous lines per baby in first week and first four weeks of life, total number of additional percutaneously and surgically placed central venous lines per baby in first four weeks of life, and other safety and efficacy measures. The treatment effect estimators used were RR, RD, and WMD when appropriate along with their 95% CI. If RD was statistically significant, then number

  19. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  20. Impact of ultrasonography on central venous catheter insertion in intensive care

    International Nuclear Information System (INIS)

    Palepu, Gopal B; Deven, Juneja; Subrahmanyam, M; Mohan, S

    2009-01-01

    The insertion of central venous catheters (CVCs) is an integral part of the management of critically ill patients. We aimed to study the impact of ultrasonography (USG) on CVC insertion in intensive care. A prospective study of 450 patients requiring CVC in the intensive care unit (ICU) of a tertiary care hospital. The patients were randomized into two groups: to have CVC insertion with USG-guidance or with the anatomic landmark technique (ALT). Data were collected on patient demographics; operator experience; and method, site and side of insertion. Outcome measures included successful insertion of CVC, number of attempts needed and complications. Internal jugular vein (IJV) cannulation was successful in 177/194 patients (91.2%) using ALT and in 200/205 patients (97.6%) using USG guidance, a significant difference of 6.4% (P = 0.006). Using ALT, 72.7% of cannulations could be accomplished in the first attempt as compared with 84.4% with USG guidance (P = 0.004). The overall complication rate was 28/399 (7%), with 19 (9.8%) complications in the ALT group and 9 (4.4%) in the USG group (age-, sex-, and operator-adjusted OR = 0.35, 95% CI: 0.13–0.96; P = 0.03). For subclavian vein catheterization, the success rate was 26/28 (92.9%) in the ALT group and 17/17 (100%) in the USG group (P = 0.52). Using ALT, 71.4% cannulation could be accomplished in the first attempt as compared with 82.4% under USG guidance (P = 0.49). The overall complication rate was 6/45 (13.3%), with 4 (14.3%) complications in the ALT group and 2 (11.8%) in the USG group (P > 0.99). Real-time USG guidance improves success rates, reduces the number of attempts and decreases the complications associated with CVC insertion, especially for the IJV, and should become the standard of care in intensive care

  1. Protocol for the realization of venous mapping by chronic venous insufficiency in lower limbs under sonographic guide

    International Nuclear Information System (INIS)

    Blanco Rojas, Diego Jose

    2013-01-01

    The current state of knowledge is reviewed with respect to the realization of lower limbs venous mapping. Venous mapping is obtained by the use of color and spectral Doppler ultrasound. Doppler ultrasound has provided a precise graphical representation of the superficial and deep venous systems. The performance of the venous mapping is considered essential for the correct handling of venous diseases. The anatomical and pathophysiological basic concepts are defined to realize the sonographic assessment of the veins of the lower limbs. The required technical aspects are revised for the realization of sonographic exploration of the patient with venous insufficiency. Sonographic findings are characterized to support the diagnostic of venous insufficiency of the lower limbs. The CEAP (clinical-etiologic-anatomic-pathophysiologic) classification is utilized to differentiate forms and degrees of severity of the disorder, and has allowed an interinstitutional comparison in clinical studies, the evaluation of treatment and monitoring of patients. A proposal is designed to perform reports that have served of guide surgical to vascular surgeons [es

  2. Colorectal cancer with venous tumor thrombosis

    OpenAIRE

    Kensuke Otani; Soichiro Ishihara; Keisuke Hata; Koji Murono; Kazuhito Sasaki; Koji Yasuda; Takeshi Nishikawa; Toshiaki Tanaka; Tomomichi Kiyomatsu; Kazushige Kawai; Hiroaki Nozawa; Hironori Yamaguchi; Toshiaki Watanabe

    2018-01-01

    Summary: Colorectal cancer is seldom accompanied by venous tumor thrombosis, and little is known about the features of venous tumor thrombosis in colorectal cancer. However, some reports show that colorectal cancer patients can develop venous tumor thrombosis and warn clinicians not to overlook this complication. In this report, we perform a review of 43 previously reported cases and investigate the characteristics of colorectal cancer accompanied by venous tumor thrombosis. The histological ...

  3. Diagnosis and endovascular treatment of multiple cerebral venous and venous sinuses thrombosis

    International Nuclear Information System (INIS)

    Li Baomin; Zhang Ji; Yin Ling; Huang Xusheng; Jiang Jinli; Liu Jun; Lang Senyang; Zhou Dingbiao; Zhu Ke

    2000-01-01

    Objective: Eighty-five cases with multiple cerebral venous and venous sinuses thrombosis including the diagnosis and endovascular therapy were reported. Methods: The long T2 and short T1 signals in the related regions of multiple venous sinuses on MRI and prolonged blood circulation time of the brain with tortuous dilatation of vein in angiography were the important characteristics for the diagnosis. Of the 85 cases, the treatment procedures were consisted of injecting urokinase intermittently via common carotid artery and intra-sinus contact thrombolysis as well as warfarin intake orally. Results: Intracranial pressure of 80 cases reduced down between 230 and 300 mm H 2 O, and clinical deficits were markedly improved within 10 days. Re-angiography of 18 cases revealed recanalization partly in 5 cases and circulation time appeared near normal i 8 cases during one week after therapy. Conclusions: Combined intraarterial thrombolysis consecutively with general anticoagulation for the treatment of multiple thrombosis in cerebral venous sinuses may be one of the effective means

  4. EARLY AND LATE COMPLICATIONS RELATED TO CENTRAL VENOUS CATHETERS IN HAEMATOLOGICAL MALIGNANCIES: A RETROSPECTIVE ANALYSIS OF 1102 PATIENTS

    Directory of Open Access Journals (Sweden)

    Salvatore Giacomo Morano

    2014-02-01

    Full Text Available Several severe complications may be associated with the use of central venous catheters (CVC. We retrospectively evaluated on a large cohort of patients the incidence of CVC-related early and late complications. From 7/99 to 12/2005, 1102 CVC have been implanted at our Institution in 881 patients with haematological malignancies (142,202 total day number of implanted CVC. Early mechanic complications were 79 (7.2% - 0.55/1,000 days/CVC. Thirty-nine episodes of early infective complications (<1 week from CVC implant occurred (3.5% - 0.3/1000 days/CVC: furthermore, 187 episodes of CVC-related sepsis (17% - 1.3/1000 days/CVC were recorded. There were 29 episodes (2.6% of symptomatic CVC-related thrombotic complications, with a median interval from CVC implant of 60 days (range 7 – 395. The rate of CVC withdrawal due to CVC-related complications was 26%. The incidence of CVC-related complications in our series is in the range reported in the literature, notwithstanding cytopenia often coexisting in haematological patients.

  5. Insulin resistance and risk of venous thromboembolism : results of a population-based cohort study

    NARCIS (Netherlands)

    Van Schouwenburg, I. M.; Mahmoodi, B. K.; Veeger, N. J. G. M.; Bakker, S. J. L.; Kluin-Nelemans, H. C.; Meijer, K.; Gansevoort, R. T.

    Background: Obesity is an established risk factor for venous thromboembolism (VTE), but it is uncertain how this is mediated. Insulin resistance has a central role in the pathophysiology of the metabolic effects of obesity. Objective: We aimed to investigate whether insulin resistance is a risk

  6. Significance of venous anastomosis in fingertip replantation.

    Science.gov (United States)

    Hattori, Yasunori; Doi, Kazuteru; Ikeda, Keisuke; Abe, Yukio; Dhawan, Vikas

    2003-03-01

    Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.

  7. Correlation of inferior vena cava (ivc) diameter and central venous pressure (cvp) for fluid monitoring in icu

    International Nuclear Information System (INIS)

    Khalil, A.; Hayat, A.

    2015-01-01

    To determine intravascular fluid status in critically ill patients using inferior vena cava diameter and correlating it with central venous pressure. Study Design: Cross sectional study. Place and Duration of Study: Intensive care department, Military Hospital Rawalpindi from Jan 2013 to Aug 2013. Material and Methods: We included 115 adult patients of both genders in age range of 18 to 87 years by consecutive sampling admitted in intensive care unit. Ultrasound guided IVC diameter was assessed in supine patients. Data was simultaneously collected from the CVP catheter. Variables included in study were age, gender, CVP, IVC diameter. Results: CVP ranged from -4 to 26 cm H/sub 2/O with mean of 8 cm H/sub 2/O (SD = 6.24). Mean IVC diameters increased with increase in CVP. Correlation between CVP and max IVC diameter was moderate and significant (r = 0.53, p < 0.001). Correlation between CVP and min IVC diameter was also moderate and significant (r = 0.58, p < 0.001). Conclusion: A simple bedside sonography of inferior vena cava diameter correlates well with extremes of CVP values and can be helpful in assessing intravascular fluid status in these patients. (author)

  8. The pericardial reflection and the tip of the central venous catheter - topographical analysis in stillborn babies

    Energy Technology Data Exchange (ETDEWEB)

    Eifinger, Frank; Vierzig, Anne; Roth, Bernhard [University Children' s Hospital, Department of Pediatric Critical Care Medicine and Neonatology, Cologne (Germany); Scaal, Martin [University of Cologne, Institute of Anatomy II, Cologne (Germany); Koerber, Friederike [University of Cologne, Department of Radiology, Cologne (Germany)

    2016-10-15

    Central venous cannulation is widely used in neonatal critical care. Pericardial tamponade caused by vessel wall perforation can occur if the catheter tip induces extravasation at the level of the pericardium. To investigate the level of the superior pericardial reflection in stillborn babies. We dissected 20 bodies (11 female, mean gestational age 33 6/7 weeks, range 25-43 weeks), with careful opening of the thoracic area. After injecting contrast medium into the pericardial sac, we introduced a catheter through the right internal jugular vein. We then took radiographs to analyse the relationship between visual osseous landmarks and the pericardium. Mean distance between the pericardial reflection at its upper end and the first thoracic vertebra was 1.3 cm (standard deviation [SD]: 0.3 cm) and did not extend over the 3rd intercostal space. The mean distance from the entry of the superior vena cava into the pericardial sac and the 1st thoracic vertebra was 2.3 cm (SD: 0.5). The upper end of the pericardial reflection in neonates at autopsy lies below the middle of the 3rd thoracic vertebra. The tip of an upper inserted catheter should not extend below the level of the 3rd intercostal space. (orig.)

  9. Peripherally inserted central catheters and upper extremity deep vein thrombosis

    International Nuclear Information System (INIS)

    Ong, B.; Gibbs, H.; Catchpole, I.; Hetherington, R.; Harper, J.

    2006-01-01

    The purpose of the study was to determine the incidence and risk factors for venous thrombosis in patients with a peripherally inserted central catheter (PICC). A retrospective study of all upper extremity venous duplex scans was carried out in the Vascular Medicine department from year 2000 to 2002 inclusive. A chart review of positive scans was undertaken to identify possible thrombotic risk factors. Of 317 upper extremity venous duplex scans carried out, 115, or 32%, were positive for upper extremity deep vein thrombosis. Three main risk factors were identified - presence of a central line, malignancy and administration of chemotherapy. PICC were the most common central line present. Symptomatic thrombosis occurred in 7% of PICC inserted for chemotherapy compared with 1% of PICC inserted for other reasons. Ten per cent of the patients receiving chemotherapy through a PICC developed a thrombosis. The post-thrombotic syndrome was infrequent following upper extremity deep vein thrombosis. Patients receiving chemotherapy through a PICC are at increased risk of thrombosis. There may be a role for prophylactic low-dose anticoagulation in these high-risk patients

  10. Venous abnormalities demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Tsukune, Y; Ashida, H; Tokuda, M; Oyama, Y [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-05-01

    CT is capable of demonstrating various venous changes. However, little have been described on this subject in the literature. Examples of various venous abnormalities such as obstructed jugular vein, superior and inferior vena cava (IVC), tumor invasion of IVC and renal vein and venous changes in portal hypertension were presented. It was stressed that noninvasive CT is a good tool in diagnosis of some of venous changes and may be able to eliminate angiography in such cases.

  11. Altered Venous Function during Long-Duration Spaceflights

    Directory of Open Access Journals (Sweden)

    Jacques-Olivier Fortrat

    2017-09-01

    Full Text Available Aims: Venous adaptation to microgravity, associated with cardiovascular deconditioning, may contribute to orthostatic intolerance following spaceflight. The aim of this study was to analyze the main parameters of venous hemodynamics with long-duration spaceflight.Methods: Venous plethysmography was performed on 24 cosmonauts before, during, and after spaceflights aboard the International Space Station. Venous plethysmography assessed venous filling and emptying functions as well as microvascular filtration, in response to different levels of venous occlusion pressure. Calf volume was assessed using calf circumference measurements.Results: Calf volume decreased during spaceflight from 2.3 ± 0.3 to 1.7 ± 0.2 L (p < 0.001, and recovered after it (2.3 ± 0.3 L. Venous compliance, determined as the relationship between occlusion pressure and the change in venous volume, increased during spaceflight from 0.090 ± 0.005 to 0.120 ± 0.007 (p < 0.01 and recovered 8 days after landing (0.071 ± 0.005, arbitrary units. The index of venous emptying rate decreased during spaceflight from −0.004 ± 0.022 to −0.212 ± 0.033 (p < 0.001, arbitrary units. The index of vascular microfiltration increased during spaceflight from 6.1 ± 1.8 to 10.6 ± 7.9 (p < 0.05, arbitrary units.Conclusion: This study demonstrated that overall venous function is changed during spaceflight. In future, venous function should be considered when developing countermeasures to prevent cardiovascular deconditioning and orthostatic intolerance with long-duration spaceflight.

  12. Fanconi anaemia with bilateral diffuse pulmonary arterio venous fistulae: a case report

    Directory of Open Access Journals (Sweden)

    Samarakoon Lasitha

    2012-03-01

    Full Text Available Abstract Background We report a patient with cytogenetically confirmed Fanconi anaemia with associated diffuse bilateral pulmonary arterio-venous fistulae. This is only the second reported case of diffuse pulmonary arterio-venous fistulae with Fanconi anaemia. Case Presentation A 16 year old Sri Lankan boy, with a cytogenetically confirmed Fanconi anaemia was admitted to University Medical Unit, National Hospital of Sri Lanka for further assessment and treatment. Both central and peripheral cyanosis plus clubbing were noted on examination. The peripheral saturation was persistently low on room air and did not improve with supplementary Oxygen. Contrast echocardiography failed to demonstrate an intra cardiac shunt but showed early crossover of contrast, suggesting the possibility of pulmonary arterio-venous fistulae. Computed tomography pulmonary angiogram was inconclusive. Subsequent right heart catheterisation revealed bilateral diffuse arterio-venous fistulae not amenable for device closure or surgical intervention. Conclusion To our knowledge, this is the second reported patient with diffuse pulmonary arterio-venous fistulae associated with Fanconi anaemia. We report this case to create awareness among clinicians regarding this elusive association. We recommend screening patients with Fanconi anaemia using contrast echocardiography at the time of assessment with transthoracic echocardiogram. Though universal screening may be impossible given the cost constraints, such screening should at least be performed in patients with clinical evidence of desaturation or when a therapeutic option such as haematopoietic stem cell transplantation is considered. Treatment of pulmonary arteriovenous fistulae would improve patient outcome as desaturation by shunting worsens the anaemic symptoms by reducing the oxygen carrying capacity of blood.

  13. Combined oral contraceptives: venous thrombosis.

    Science.gov (United States)

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  14. Venous chest anatomy: clinical implications

    International Nuclear Information System (INIS)

    Chasen, M.H.; Charnsangavej, C.

    1998-01-01

    This article provides a practical approach to the clinical implications and importance of understanding the collateral venous anatomy of the thorax. Routine radiography, conventional venography, computed tomography (CT), and magnetic resonance (MR) imaging studies provide correlative anatomic models for the demonstration of how interconnecting collateral vascular networks within the thorax maintain venous stability at all times. Five major systems comprise the collateral venous network of the thorax ( Fig. 1 ). These include the paravertebral, azygos-hemiazygos, internal mammary, lateral thoracic, and anterior jugular venous systems (AJVS). The five systems are presented in the following sequence: (a) a brief introduction to the importance of catheter position and malposition in understanding access to the thoracic venous system, (b) the anatomy of the azygos-hemiazygos systems and their relationship with the paravertebral plexus, (c) the importance of the AJVS, (d) 'loop' concepts interconnecting the internal mammary and azygos-hemiazygos systems by means of the lateral thoracic and intercostal veins, and (e) the interconnecting venous networks on the thoracic side of the thoracoabdominal junction. Certain aspects of the venous anatomy of the thorax will not be discussed in this chapter and include (a) the intra-abdominal anastomoses between the superior and inferior vena cavae (IVC) via the internal mammary, lateral thoracic, and azygos-hemiazygos systems (beyond the scope of this article), (b) potential collateral vessels involving vertebral, parascapular, thyroidal, thymic, and other smaller veins that might anastomose with the major systems, and (c) anatomic variants and pitfalls that may mimic pathologic conditions (space limitations). (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  15. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  16. Venous pump of the calf: a study of venous and muscular pressures.

    Science.gov (United States)

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and

  17. Thrombophilia in children with venous thromboembolic disease.

    Science.gov (United States)

    Revel-Vilk, Shoshana; Kenet, Gili

    2006-01-01

    Venous thromboembolic events (VTEs) in children are usually associated with underlying clinical conditions such as central venous line, cancer and cardiac diseases. The objective of this review is to present the importance of thrombophilia to the occurrence of childhood VTE. The reported prevalence of thrombophilia in children with VTE varies extremely between 10% and 78% in different registries. The variation in the reported prevalence most probably reflects differences in the clinical characteristics of the children studied and differences in study designs. The initial management of children with thrombophilia and VTE is similar to those individuals who do not have a specific inherited thrombophilic risk factor, except in the rare events of homozygous deficiencies of prothrombotic coagulation proteins. The impact of thrombophilic markers on long-term therapy and outcome of children with VTE has not been completely clarified. According to the current guidelines for thrombophilia, all children with VTE should be tested for a full panel of genetic and acquired prothrombotic traits. However, re-evaluation of co-morbid risk factors other than thrombophilic markers and careful consideration of the prognostic value of thrombophilic markers might help to change future attitude from the rigidity of current guidelines to more rational schemes.

  18. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  19. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Pekindil, Goekhan [Department of Radiology, Trakya University School of Medicine, 22030 Edirne (Turkey); Varol, Fuesun G. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Ali Yuece, M. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Yardim, Turgut [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey)

    1999-03-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period.

  20. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    International Nuclear Information System (INIS)

    Pekindil, Goekhan; Varol, Fuesun G.; Ali Yuece, M.; Yardim, Turgut

    1999-01-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period

  1. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  2. [Project work: formation of health-care personnel for self-care of tunnelled central venous catheters in hemodialysis patients of the territory].

    Science.gov (United States)

    Morale, Walter; Patanè, D; Incardona, C; Seminara, G; Malfa, P; L'Anfusa, G; Calcara, G; Bisceglie, P; Puliatti, D; Di Landro, D

    2013-01-01

    Scientific data from current literature demonstrate an incidence of bacteraemia due to tunnelled central venous catheter (tCVC) use accounting for 1.6 / 1000 days per tCVC, with a range of 1.5 to 1.8. In Sicily no data on the incidence of tCVC- related bacteraemia are available. In our hospital, tCVC infection occurs 2.4 times in 1000 days during CVC use. A retrospective analysis carried out from 2006 to 2012 was performed on 650 patients with tunnelled catheters. Of the subjects who received tCVC in our hospital, 90% were destined to undergo haemodialysis in a private health care environment outside our hospital. In order to improve the aforementioned infection outcome, we planned and implemented a specific work project. The work project (WP) was subdivided into two steps: 1) The first step was further subdivided into two sub-phases. The first was principally concerned with the implementation of educational courses, conducted directly on the ward and aimed at the implementation of meticulous nursing regimes for the care of tCVC by our health care nurse. The courses were entitled Management of Vascular Access: from doing - to teaching to do!. These educational courses were organized by the Nephrology Department, which takes care of the management and handling of the major complications of tCVCs for the maintenance of haemodialysis. After this first step, the nurses who had participated became the promoters of the second part of the course, which concerned the development of know-how within an outpatient clinic, which deals exclusively with the nursing management of tCVCs. 2) The title of the second phase was Therapeutic Education: self-Care and understanding and managing your venous access at home. The aim of this step was the integration of correct in-hospital care with that available in outsourced private institutions, via the involvement of the patient in the management of their own central venous access. During our training project, a more detailed analysis of

  3. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  4. Totally implantable central venous access port infections in patients with digestive cancer: incidence and risk factors.

    Science.gov (United States)

    Touré, Abdoulaye; Vanhems, Philippe; Lombard-Bohas, Catherine; Cassier, Philippe; Péré-Vergé, Denis; Souquet, Jean-Christophe; Ecochard, René; Chambrier, Cécile

    2012-12-01

    Central venous access port-related bloodstream infection (CVAP-BSI) is associated with morbidity and mortality in patients with cancer. This study examined the incidence rates and risk factors for CVAP-BSI in adult patients with digestive cancer. This prospective observational cohort study was performed from 2007 to 2011 in 2 oncology units of a university hospital. Incidence rate was expressed as number of CVAP-BSI per 1,000 catheter-days. A Cox regression model was used to identify risk factors for CVAP-BSI. A total of 315 patients were included. CVAP-BSI occurred in 41 patients (13.0%). The overall incidence rate was 0.76/1,000 catheter-days. The rate was higher in patients with esophageal cancer (1.28. P = .05) and pancreatic cancer (1.24; P = .007). Risk factors independently associated with CVAP-BSI were World Health Organization performance status between 2 and 4, catheter utilization-days in the previous month, pancreatic cancer, and parenteral nutrition. Coagulase-negative Staphylococci and enterobacteria were the main microorganisms isolated. In adult patients with digestive cancer, pancreatic cancer, cumulative catheter utilization-days, World Health Organization performance status, and parenteral nutrition were identified as independent risk factors for CVAP-BSI. Patients with any of these risk factors could be candidates for preventive strategies. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Current concepts in repair of extremity venous injury.

    Science.gov (United States)

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely

  6. Cerebral venous thrombosis

    International Nuclear Information System (INIS)

    Soralova, T.; Sevcikova, H.; Petersky, D.

    2014-01-01

    We decided to process this theme due to its nonspecific clinical features as they often cause diagnostic problems not only to clinicians but also to diagnostic. It is important to think of this disease mainly in young women who administer hormonal contraception. Imaging methods play the crucial role in diagnostic of cerebral venous sinus thrombosis. The gold standard is a native CT of brain which shows the venous sinus thrombosis as a hyperdense lesion in the locus of the sinus (dense triangle sign), CT venography shows the sinus thrombosis as a defect in a contrast filling of the venous sinus (empty delta sign). Other investigative methods are magnetic resonance imaging or MRA. In short we also mention quite a rare but more serious thrombosis of profound cerebral veins v. cerebri magna-Galeni, vv. cerebri internae). The importance of early diagnostic and non specificity of symptoms is presented in 3 clinical cases that are the part of this work. (author)

  7. Prediction of central venous catheter-related bloodstream infections (CRBSIs) in patients with haematologic malignancies using a modified Infection Probability Score (mIPS).

    Science.gov (United States)

    Schalk, Enrico; Hanus, Lynn; Färber, Jacqueline; Fischer, Thomas; Heidel, Florian H

    2015-09-01

    The aim of this study was to predict the probability of central venous catheter-related bloodstream infections (CRBSIs) in patients with haematologic malignancies using a modified version of the Infection Probability Score (mIPS). In order to perform a prospective, mono-centric surveillance of complications in clinical routine due to short-term central venous catheters (CVCs) in consecutive patients receiving chemotherapy from March 2013 to September 2014, IPS was calculated at CVC insertion and removal (mIPSin and mIPSex, respectively). We used the 2012 Infectious Diseases Working Party of the German Society of Haematology and Medical Oncology (AGIHO/DGHO) criteria to define CRBSI. In total, 143 patients (mean 59.5 years, 61.4 % male) with 267 triple-lumen CVCs (4044 CVC days; mean 15.1 days, range 1-60 days) were analysed. CVCs were inserted for therapy of acute leukaemia (53.2 %), multiple myeloma (24.3 %) or lymphoma (11.2 %), and 93.6 % were inserted in the jugular vein. A total of 66 CRBSI cases (24.7 %) were documented (12 definite/13 probable/41 possible). The incidence was 16.3/1000 CVC days (2.9/3.1/10.1 per 1000 CVC days for definite/probable/possible CRBSI, respectively). In CRBSI cases, the mIPSex was higher as compared to cases without CRBSI (13.1 vs. 7.1; p < 0.001). The best mIPSex cutoff for CRBSI prediction was 8 points (area under the curve (AUC) = 0.77; sensitivity = 84.9 %, specificity = 60.7 %, negative predictive value = 92.4 %). For patients with an mIPSex ≥8, the risk for a CRBSI was high (odds ratio [OR] = 5.9; p < 0.001) and even increased if, additionally, CVC had been in use for about 10 days (OR = 9.8; p < 0.001). In case other causes of infection are excluded, a mIPSex ≥8 and duration of CVC use of about 10 days predict a very high risk of CRBSI. Patients with a mIPSex <8 have a low risk of CRBSI of 8 %.

  8. Penile venous surgery for treating erectile dysfunction: Past, present, and future perspectives with regard to new insights in venous anatomy

    Directory of Open Access Journals (Sweden)

    Cheng-Hsing Hsieh

    2016-06-01

    Full Text Available In the physiologic model of normal erectile function, a healthy veno-occlusive mechanism is essential to initiate and maintain a rigid erection. The surgical treatment of patients with venous leakage, which is synonymous with corporoveno-occlusive dysfunction (CVOD, was based on the decreased venous outflow during the erection process. The initial reports of short-term results were promising, but the long-term benefits of penile venous ligation surgery were limited. Most clinical guideline panels concluded that surgeries performed in an attempt to limit the venous outflow of the penis were not recommended. Consequently, this surgery was nearly abandoned in most medical societies worldwide. These unfavorable postoperative outcomes seemed attributable to the indispensable usage of electrocautery and insufficient venous management, based on conventional penile venous anatomy. Advances in better understanding of human penile venous anatomy has enabled the development of refined penile venous stripping surgery. The thorough stripping surgery is an even more radical procedure, which is an even more radical procedure, and seems to be a viable option for the treatment of CVOD, however, there is still a need for further study with well-defined diagnostic criteria, and standardized patient and partner outcome assessment.

  9. Cerebral venous outflow and cerebrospinal fluid dynamics

    Directory of Open Access Journals (Sweden)

    Clive B. Beggs

    2014-12-01

    Full Text Available In this review, the impact of restricted cerebral venous outflow on the biomechanics of the intracranial fluid system is investigated. The cerebral venous drainage system is often viewed simply as a series of collecting vessels channeling blood back to the heart. However there is growing evidence that it plays an important role in regulating the intracranial fluid system. In particular, there appears to be a link between increased cerebrospinal fluid (CSF pulsatility in the Aqueduct of Sylvius and constricted venous outflow. Constricted venous outflow also appears to inhibit absorption of CSF into the superior sagittal sinus. The compliance of the cortical bridging veins appears to be critical to the behaviour of the intracranial fluid system, with abnormalities at this location implicated in normal pressure hydrocephalus. The compliance associated with these vessels appears to be functional in nature and dependent on the free egress of blood out of the cranium via the extracranial venous drainage pathways. Because constricted venous outflow appears to be linked with increased aqueductal CSF pulsatility, it suggests that inhibited venous blood outflow may be altering the compliance of the cortical bridging veins.

  10. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?; 'Chronische zerebrospinale venoese Insuffizienz' bei Multipler Sklerose. Ist die Multiple Sklerose eine Erkrankung des zerebrospinalen venoesen Abflusssystems?

    Energy Technology Data Exchange (ETDEWEB)

    Wattjes, M.P. [VU Univ. Medical Center, Amsterdam (Netherlands). Dept. of Radiology; Doepp, F. [Universitaetsklinik Charite, Berlin (Germany). Neurologische Klinik; Bendszus, M. [Heidelberg Univ. (Germany). Abt. fuer Neuroradiologie; Fiehler, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Neuroradiologische Diagnostik und Intervention

    2011-06-15

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  11. Chronic venous disease.

    Science.gov (United States)

    Wolinsky, Claire D; Waldorf, Heidi

    2009-11-01

    Identifying characteristic cutaneous findings is important in determining the appropriate management of certain venous diseases. The health care provider should be familiar with the classic description of patterns and distributions of skin manifestations, such as varicose veins, stasis dermatitis, palpable cord, petechiae, and telangiectasias. In addition to the gross appearance of the skin, a skin biopsy may help elucidate a diagnosis. General treatment and prevention of the underlying venous pathology is essential. Furthermore, specific management of skin findings should include therapy to ameliorate progression of disease and symptomatology when warranted.

  12. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  13. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  14. Venous thromboembolism and arterial complications.

    Science.gov (United States)

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Venous trauma in the Lebanon War--2006.

    Science.gov (United States)

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can

  16. Evaluation of risk factors for thrombophilia in patients with cerebral venous thrombosis

    OpenAIRE

    Osman Yokuş; Özlem Şahin Balçık; Murat Albayrak; Funda Ceran; Simten Dağdaş; Mesude Yılmaz; Gülsüm Özet

    2010-01-01

    Objective: The increased risk for thrombosis is known as hypercoagulability or thrombophilia. In our study, we aimed to determine the frequency of the identified defects for thrombophilia in patients with central venous thrombosis aged under 50 years and to compare results with the findings in the current literature. Materials and Methods: Forty-three patients (16-50 years old) were retrospectively evaluated. Thrombophilia investigation included determinations of protein C, protein S, antithr...

  17. Venous infraction of developmental venous anomaly: A case report with perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Youn; Kim, Hye Jeong; Hyun, Su Jeong; Kim, Hee Yeong; Kim, Han Myun; Hwang, Ji Young; Hong, Hye Suk; Woo, Ji Young; Yang, Ik [Dept. of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Soo [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2017-06-15

    Developmental venous anomaly (DVA) is a common congenital venous malformation characterized by dilated medullary veins in caput medusa configuration and a draining vein. Despite the high incidence of DVAs, they are benign anatomic variations and rarely cause symptoms. Here, we report computed tomography and magnetic resonance imaging findings with perfusion images of acute infarction from underlying DVA in a 63-year-old female patient who presented with acute onset of neurologic symptoms and recovered without any neurologic deficit.

  18. Chronic Venous Disease under pressure

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan)

    2013-01-01

    textabstractIn chapter 1 we provide a general introduction of this thesis. Chronic venous disease (CVD) is a common medical condition that affects 2-64% of the worldwide population and leads to leg ulcers in 1% of the Western population. Venous leg ulceration (VLU) has an unfavorable prognosis with

  19. Surgical management of venous malformations.

    Science.gov (United States)

    Loose, D A

    2007-01-01

    Among vascular malformations, the predominantly venous malformations represent the majority of cases. They form a clinical entity and therefore need clear concepts concerning diagnosis and treatment. This paper presents an overview of contemporary classification as well as tactics and techniques of treatment. According to the Hamburg Classification, predominantly venous malformations are categorized into truncular and extratruncular forms, with truncular forms distinguished as obstructions and dilations, and extratruncular forms as limited or infiltrating. The tactics of treatment represent surgical and non-surgical methods or combined techniques. Surgical approaches utilize different tactics and techniques that are adopted based on the pathologic form and type of the malformation: (I) operation to reduce the haemodynamic activity of the malformation; (II) operation to eliminate the malformation; and (III) reconstructive operation. As for (I), a type of a tactic is the operation to derive the venous flow. In (II), the total or partial removal of the venous malformation is demonstrated subdivided into three different techniques. In this way, the infiltrating as well as the limited forms can be treated. An additional technique is dedicated to the treatment of a marginal vein. Approach (III) involves the treatment of venous aneurysms, where a variety of techniques have been successful. Long-term follow-up demonstrates positive results in 91% of the cases. Congenital predominantly venous malformations should be treated according to the principles developed during the past decades in vascular surgery, interventional treatment and multidisciplinary treatment. The days of predominantly conservative treatment should be relegated to the past. Special skills and experiences are necessary to carry out appropriate surgical strategy, and the required operative techniques should be dictated by the location and type of malformation and associated findings.

  20. Safety, dose, and timing of reteplase in treating occluded central venous catheters in children with cancer.

    Science.gov (United States)

    Terrill, Kelly R; Lemons, Richard S; Goldsby, Robert E

    2003-11-01

    Recombinant tissue plasminogen activator, alteplase, began to be commonly used to restore the patency of occluded central venous catheters (CVCs) as urokinase production was halted in the late 1990s. However, alteplase often requires an extended dwell time to restore patency to occluded CVCs. In adults, reteplase, a newer thrombolytic agent, has been reported to restore patency to CVCs in 30 minutes. The authors prospectively evaluated the safety and efficacy of reteplase in restoring patency to occluded CVCs in children with cancer. This was a dose escalation trial. The dose of reteplase was initiated at 0.1 units and increased by increments of 0.1 units to a maximum dose of 0.4 units. Each dose was tested on at least three participants. Time to patency after reteplase administration was recorded by nurses caring for the patients. Attempts to access the line occurred every 15 minutes for 1 hour. CVCs that remained occluded after 1 hour were treated with alteplase. Reteplase was administered to 15 clotted CVCs. Twelve of the 15 were cleared with an average dwell time of 38 minutes. The time to patency did not appear to correlate with the dose. No adverse events were reported. Reteplase can restore patency to occluded CVCs in a pediatric population. Reteplase appears to have comparable efficacy with alteplase, but reteplase may require shorter dwell times. A prospective, randomized, clinical trial is warranted to determine whether reteplase is as effective as alteplase in restoring patency to occluded CVCs.

  1. Horner's syndrome in patients admitted to the intensive care unit that have undergone central venous catheterization: a prospective study.

    Science.gov (United States)

    Butty, Z; Gopwani, J; Mehta, S; Margolin, E

    2016-01-01

    PurposeCentral venous catheterization (CVC) is estimated to be performed in millions of patients per year. Swan-Ganz catheters used for CVC are most often inserted into the internal jugular vein and during this procedure they may come into contact with the sympathetic chain. This study aims to determine the incidence of Horner's syndrome in patients admitted to intensive care unit that have undergone internal jugular CVC insertion during their admission and to determine whether ultrasonography-assisted insertion has decreased the frequency of this complication.Patients and methodsA total of 100 prospective patients admitted to the ICU were examined for the presence of anisocoria and ptosis after undergoing recent CVC. Presence of Horner's syndrome was confirmed by testing with 0.5% apraclonidine and looking for the reversal of anisocoria.ResultsFrequency of Horner's syndrome after CVC was 2% in a sample of 100 prospectively examined patients.ConclusionHorner's syndrome remains a relatively rare but definitive complication of CVC. ICU physicians should be educated about its existence and prevalence and ophthalmologists should inquire about any history of ICU admission necessitating CVC insertion in any patient presenting with Horner's syndrome.

  2. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro, E-mail: ksofue@ncc.go.jp [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Department of Radiology, Kobe University, Graduate School of Medicine (Japan); Arai, Yasuaki; Takeuchi, Yoshito [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University, Graduate School of Medicine (Japan)

    2013-11-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required.

  3. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Arai, Yasuaki; Takeuchi, Yoshito; Sugimura, Kazuro

    2013-01-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required

  4. Método bundle na redução de infecção de corrente sanguínea relacionada a cateteres centrais: revisão integrativa Método bundle en la redución de infecciones relacionadas a catéteres centrales: una revisión integrativa Care bundle to reduce central venous catheter-related bloodstream infection: an integrative review

    Directory of Open Access Journals (Sweden)

    Juliana Dane Pereira Brachine

    2012-12-01

    Full Text Available Trata-se de uma revisão integrativa da literatura, que objetivou identificar intervenções baseadas em evidência que compõem o método bundle, designados à redução de infecção de corrente sanguínea relacionada ou associada a cateter intravenoso central. Para a coleta de dados online, em bases nacionais e internacionais, foram utilizados a palavra-chave bundle e os descritores catheter-related infection, infection control e central venous catheterization, resultando, após aplicação dos critérios de inclusão, amostra de quinze artigos. Este trabalho evidenciou cinco intervenções como as mais frequentemente empregadas na construção dos bundles: higienização das mãos, gluconato de clorexidina como antisséptico para pele, uso de barreira máxima de precaução durante a inserção cateter, evitar acessar veia femoral e verificar necessidade diária de permanência do cateter, com sua remoção imediata quando não mais indicado. A maioria dos estudos demonstrou resultados estatisticamente significantes na redução de infecção de corrente sanguínea relacionada ou associada a cateter intravenoso central.Esta es una revisión integradora tuvo como objetivo identificar intervenciones basadas en evidencias que componen método bundle de reducción de infección sanguínea relacionadas o asociadas con catéter intravenoso central. Para recopilar los datos en las bases brasileñas e internacionales, utilizando la palabra clave bundle y los descriptores infecciones relacionadas con catéteres, control de infecciones y cateterización venosa central, identificando, con los criterios de inclusión, muestra de quince artículo. Este estudio muestra cinco intervenciones como comúnmente empleadas en los métodos bundles: higiene de las manos, clorhexidina como antiséptico para la piel, uso de precaución de barrera máxima durante la inserción del catéter, evitar el acceso de la vena femoral y comprobar la necesidad diaria del cat

  5. Prevalence of lower extremity venous duplication

    Directory of Open Access Journals (Sweden)

    Simpson William

    2010-01-01

    Full Text Available Purpose: This retrospective study was performed to determine the prevalence of lower extremity venous duplication using duplex ultrasound in the patient population of a large urban medical center. Materials and Methods: The reports of all lower extremity venous ultrasound examinations performed at our institution between January 1, 2002 and December 31, 2002 were reviewed. Ultrasound examinations that were performed for purposes other than the detection of lower extremity deep vein thrombosis were excluded. The prevalence of duplication and its specific location were recorded. In addition, the prevalence of thrombus and its specific location were also recorded. Results: A total of 3118 exams were performed in 2664 patients. Of the 2664 patients, 2311 had only one examination performed during the study period; 353 patients had more than one examination performed. We found that 10.1% of patients (270/2664 had at least one venous segment duplicated and 5.4% of patients (143/2664 had a thrombus in at least one venous segment. There was a statistically significant difference in the prevalence of both duplication and thrombus with a change in venous segment. Only 0.4% of patients (11/2664 had thrombus within a duplicated segment. Of those who had more than one examination performed, 15.3% (54/353 had the same venous segment(s seen on one examination but not another. Conclusion: Lower extremity venous duplication is a frequent anatomic variant that is seen in 10.1% of patients, but it may not be as common as is generally believed. It can result in a false negative result for deep vein thrombosis.

  6. Computer identification of symptomatic deep venous thrombosis associated with peripherally inserted venous catheters.

    Science.gov (United States)

    Evans, R Scott; Linford, Lorraine H; Sharp, Jamie H; White, Gayle; Lloyd, James F; Weaver, Lindell K

    2007-10-11

    Peripherally inserted central catheters (PICCs) are considered a safe method to provide long-term antibiotic therapy, chemotherapy and nutrition support. Deep venous thrombosis (DVT) is a complication that requires early PICC removal, may extend hospitalization and can result in pulmonary embolism. PICC insertion teams strive to understand risk factors and develop methods to prevent DVTs. However, they can only manage what they can measure. At LDS Hospital, identification of PICC associated DVTs was dependent on verbal notification or manual surveillance of more than a thousand free-text vascular reports. Accurate DVT rates were not known which hindered prevention. We describe the development of a computer application (PICC-DVT monitor) to identify PICC associated DVTs each day. A one-year evaluation of the monitor by the PICC team and a review of 445 random vascular reports found a positive predictive value of 98%, sensitivity of 94%, specificity of 100% and a PICC team associated DVT rate of 2.8%.

  7. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  8. Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Gerasia, Roberta; Maggio, Simona; Luca, Angelo [Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Piazza, Marcello [Department of Anesthesia, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Tuzzolino, Fabio [Department of Information Technology, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy)

    2014-09-10

    Ultrasound-guided central venous puncture and fluoroscopic guidance during central venous catheter (CVC) positioning optimizes technical success and lowers the complication rates in children, and is therefore considered standard practice. The purpose of this study was to compare the radiation exposure levels recorded during CVC placement in children weighing less than 10 kg in procedures performed using an image intensifier-based angiographic system (IIDS) to those performed in a flat-panel detector-based interventional suite (FPDS). A retrospective review of 96 image-guided CVC placements, between January 2008 and October 2013, in 49 children weighing less than 10 kg was performed. Mean age was 8.2 ± 4.4 months (range: 1-22 months). Mean weight was 7.1 ± 2.7 kg (range: 2.5-9.8 kg). The procedures were classified into two categories: non-tunneled and tunneled CVC placement. Thirty-five procedures were performed with the IIDS (21 non-tunneled CVC, 14 tunneled CVC); 61 procedures were performed with the FPDS (47 non-tunneled CVC, 14 tunneled CVC). For non-tunneled CVC, mean DAP was 113.5 ± 126.7 cGy cm{sup 2} with the IIDS and 15.9 ± 44.6 cGy . cm{sup 2} with the FPDS (P < 0.001). For tunneled CVC, mean DAP was 84.6 ± 81.2 cGy . cm{sup 2} with the IIDS and 37.1 ± 33.5 cGy cm{sup 2} with the FPDS (P = 0.02). The use of flat-panel angiographic equipment reduces radiation exposure in small children undergoing image-guided CVC placement. (orig.)

  9. Normal venous anatomy and physiology of the lower extremity.

    Science.gov (United States)

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  10. A Technique for Autologous Priming of the Veno-Venous Bypass Circuit during Liver Transplantation

    OpenAIRE

    Shackelford, Anthony G.; Hodge, Ashley B.; Chavin, Kenneth D.; Baliga, Prabhakar K.

    2011-01-01

    Orthotopic liver transplantations (OLT) have been associated with significant blood loss and hemodilution, necessitating significant homologous blood component replacement. Increasing administration of homologous blood products has been found to be inversely related to patient and graft survival. Various methods to reduce the amount of blood products patients receive during OLT, such as antifibrinolytic therapy, thromboelastography-guided transfusion, phlebotomy, reduced central venous pressu...

  11. Incidence, determinants and the transient impact of cancer treatments on venous thromboembolism risk among lymphoma patients in Denmark

    DEFF Research Database (Denmark)

    Lund, Jennifer L; Østgård, Lene Sofie; Prandoni, Paolo

    2015-01-01

    BACKGROUND: Valid estimation of the incidence and risk factors for venous thromboembolism (VTE) among lymphoma patients has been limited by small studies focused on selected lymphoma subtypes and failure to account for death as a competing risk. Using a nationwide cohort of Danish lymphoma patients...... logistic regression models and adjusted odds ratios (aORs). RESULTS: VTE IRs were >40/1000person-years within 180days post-diagnosis, decreasing to 8/1000person-years in year two. VTE risk was 2.9% and 3.5% at 1 and 2years, respectively. Lymphoma subtype, central nervous system involvement, and elevated...... lactate dehydrogenase were associated with VTE risk. Central venous catheter use increased the transient odds of VTE (aOR=6.7 (1.2, 28.1)). CONCLUSIONS: We report a lower VTE incidence among lymphoma patients compared with prior studies. Lymphoma aggressiveness was the main driver of baseline VTE risk...

  12. Venous injury in abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Arabinda K. [Nemours A. I. duPont Hospital for Children, Department of Radiology, Wilmington, DE (United States); Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B. [Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Dias, Mark S. [Hershey Medical Center, Department of Neurosurgery, Hershey, PA (United States)

    2015-11-15

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  13. Venous injury in abusive head trauma

    International Nuclear Information System (INIS)

    Choudhary, Arabinda K.; Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B.; Dias, Mark S.

    2015-01-01

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  14. Erythrocytes and von Willebrand factor in venous thrombosis

    NARCIS (Netherlands)

    Smeets, M.W.J.

    2018-01-01

    Venous thromboembolism represents the third leading vascular disease after myocardial infarction and stroke. Erythrocytes, the most abundant cells in venous thrombi, were thought to be innocent bystanders that become tangled up in the fibrin mesh of venous thrombi. However, this thesis describes

  15. Dural sinus thrombosis - A rare manifestation of internal jugular venous occlusion

    Directory of Open Access Journals (Sweden)

    Pooja Binnani

    2012-01-01

    Full Text Available The dural sinus thrombosis is an uncommon complication of a commonly done procedure of central venous catheterisation. We present a case of massive hemorrhagic venous infarct with gross cerebral edema due to dural sinus thrombosis along with right internal jugular vein thrombus. A 21-year-old male patient presented to the emergency department with fever and swelling of the right neck four days following discharge after his prior hospitalization two weeks ago for acute renal failure due to severe gastroenteritis, when he underwent hemodialysis through right internal jugular access. On presentation, he was conscious, with swelling on right side of the neck, which was diagnosed as right internal jugular vein occlusion. However, he rapidly dete-riorated and developed signs of raised intracranial pressure despite being on treatment with heparin. He was diagnosed as having massive hemorrhagic cerebral venous infarct with gross cerebral edema complicated with shift of the ventricles to the left due to dural sinus thrombosis. Despite emergency decompressive craniotomy, he succumbed in the next two days due to coning. Asymptomatic catheter-related thrombosis is frequent in the intensive care units, but major complications like retrograde extension into dural sinus causing thrombosis is rare. A high index of suspicion is required to diagnose this major catastrophe for an early and meaningful intervention.

  16. Surgical insertion of central venous catheters in low-birth-weight ...

    African Journals Online (AJOL)

    Aim: Neonatal central vascular access (CVA) represents a daily practice in neonatal intensive care unit. Low birth weight (LBW) neonates pose a challenge to anesthetists who try the landmark technique to cannulate central veins. We reported our experience of open surgical cutdown (OSC) to insert catheters through right ...

  17. Microsurgical anatomy of the central lobe.

    Science.gov (United States)

    Frigeri, Thomas; Paglioli, Eliseu; de Oliveira, Evandro; Rhoton, Albert L

    2015-03-01

    The central lobe consists of the pre- and postcentral gyri on the lateral surface and the paracentral lobule on the medial surface and corresponds to the sensorimotor cortex. The objective of the present study was to define the neural features, craniometric relationships, arterial supply, and venous drainage of the central lobe. Cadaveric hemispheres dissected using microsurgical techniques provided the material for this study. The coronal suture is closer to the precentral gyrus and central sulcus at its lower rather than at its upper end, but they are closest at a point near where the superior temporal line crosses the coronal suture. The arterial supply of the lower two-thirds of the lateral surface of the central lobe was from the central, precentral, and anterior parietal branches that arose predominantly from the superior trunk of the middle cerebral artery. The medial surface and the superior third of the lateral surface were supplied by the posterior interior frontal, paracentral, and superior parietal branches of the pericallosal and callosomarginal arteries. The venous drainage of the superior two-thirds of the lateral surface and the central lobe on the medial surface was predominantly through the superior sagittal sinus, and the inferior third of the lateral surface was predominantly through the superficial sylvian veins to the sphenoparietal sinus or the vein of Labbé to the transverse sinus. The pre- and postcentral gyri and paracentral lobule have a morphological and functional anatomy that differentiates them from the remainder of their respective lobes and are considered by many as a single lobe. An understanding of the anatomical relationships of the central lobe can be useful in preoperative planning and in establishing reliable intraoperative landmarks.

  18. VENOUS INSUFFICIENCY AND THROMBOEMBOLIC DISEASE IN BARIATRIC SURGERY PATIENTS

    Directory of Open Access Journals (Sweden)

    Bonno van BELLEN

    2013-09-01

    Full Text Available Context Morbid obesity is associated with various co-morbidities, including chronic venous insufficiency. Bariatric surgery is the only effective treatment for morbid obesity, but with potential risks and possible complications, including venous thromboembolism. Objective To determine the prevalence of clinical and ultrasonographic signs of chronic venous insufficiency in morbid obese patients in preparation for bariatric surgery and the incidence of post-operative venous thromboembolic disease. Methods Patients on work-up for bariatric surgery of Centro Terapêutico Especializado em Fígado (CETEFI and Pro-Gastro surgical teams of the Hospital Beneficência Portuguesa de São Paulo were included. The analysed data were pre-operative findings for venous insufficiency (CEAP - clinical, etiological, anatomical, physiopathologic - classification and venous ultrassonographic findings, type of surgery (open or laparoscopic, abdominal circumference, body mass index (BMI and post-operative ultrassonography search for venous insufficiency and deep venous thrombosis. Results Between March 2007 and December 2009, 95 patients candidates for bariatric surgery had clinical and duplex scan evaluation of the lower limbs venous system. Of the 95 patients, 53 were submitted to the surgical procedure. There was a predominance of women (77.9%, the average age was 38.5 years, average preoperative weight 124.6 kg and average BMI of 45.5 kg/m2. Regarding obesity, 16.8% were obese, and 83.1% were morbidly obese. In relation to the venous findings, 86.3% of the patients did fit CEAP classification less than 3 and 13.7% greater than or equal to 3. Among the post-operative complications, there were four cases of wound infection. Three patients developed post-operative distal venous thrombosis (7.5%, but no one had clinically manifested pulmonary embolism. Conclusion No relation between BMI, CEAP classification and venous ultrassonographic findings were found. Although

  19. Venous anomalies and abnormalities of the posterior fossa

    International Nuclear Information System (INIS)

    Goulao, A.; Alvarez, H.; Garcia Monaco, R.; Pruvost, P.; Lasjaunias, P.

    1990-01-01

    The authors report a series of 16 patients with venous anomalies or abnormalities of the posterior fossa studied by angiography, CT and/or MRI. We believe that so-called 'venous angioma' are extreme anatomic variants that drain normal territories, and we prefer to call them developmental venous anomalies (DVA). Posterior fossa DVA, like the supra-tentorial ones are classified according to their drainage into deep and superficial type. They are exclusively located in the cerebellum or tectum. In 4 cases DVA was an incidental finding, in 3 an associated cerebral venous malformation (CVM) was found and felt to be the cause of the symptoms and only in one (Trigeminal pain) was a link between both suspected. Cavernous venous malformation (CVM) were found in frequent association with DVA (27%). 4 cases were single and 2 multiple. 5 CVM were located in the brain stem and 3 in the cerebellum. The clinical and radiological files were reviewed and a direct relationship between symptoms and localization was found in all patients with CVM. In 2 cases venous dysplasia was found: 1 Sturge-Weber and 1 First branchial arch syndrome. Both posterior fossa venous abnormalities were incidental findings. (orig.)

  20. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  1. [Risk Factors for Oxaliplatin-Induced Phlebitis and Venous Pain, and Evaluation of the Preventive Effect of Preheating with a Hot Compress for Administration of Oxaliplatin].

    Science.gov (United States)

    Nakauchi, Kana; Kawazoe, Hitoshi; Miyajima, Risa; Waizumi, Chieko; Rokkaku, Yuki; Tsuneoka, Kikue; Higuchi, Noriko; Fujiwara, Mitsuko; Kojima, Yoh; Yakushijin, Yoshihiro

    2015-11-01

    Venous pain induced by oxaliplatin(L-OHP)is a clinical issue related to adherence to the Cape OX regimen. To prevent LOHP- induced venous pain, we provided nursing care to outpatients who were administered a preheated L -OHP diluted solution using a hot compress. We retrospectively evaluated the risk factors for colorectal cancer patients who had L -OHP induced phlebitis and venous pain. Furthermore, the preventive effect of nursing care was compared between inpatients and outpatients from January 2010 to March 2012. At the L-OHP administration site, any symptoms were defined as phlebitis, whereas pain was defined as venous pain. A total of 132 treatment courses among 31 patients were evaluated. Multivariate logistic regression analysis revealed that both phlebitis and venous pain were significantly more common in female patients (adjusted odds ratio, 2.357; 95%CI: 1.053-5.418; and adjusted odds ratio, 5.754; 95%CI: 2.119-18.567, respectively). The prevalence of phlebitis and venous pain did not differ between inpatients and outpatients (phlebitis, 61.3% vs 67.7%; venous pain, 29.0%vs 19.4%). These results suggest that administration of L-OHP via a central venous route should be considered in female patients.

  2. Analysis of risk factors and the establishment of a risk model for peripherally inserted central catheter thrombosis

    OpenAIRE

    Fang Hu; Ruo-Nan Hao; Jie Zhang; Zhi-Cheng Ma

    2016-01-01

    Objective: To investigate the main risk factors of peripherally inserted central catheter (PICC) related upper extremity deep venous thrombosis and establish the risk predictive model of PICC-related upper extremity deep venous thrombosis. Methods: Patients with PICC who were hospitalized between January 2014 and July 2015 were studied retrospectively; they were divided into a thrombosis group (n = 52), with patients who had a venous thrombosis complication after PICC, and a no-thrombosis ...

  3. Changing epidemiology of central venous catheter-related bloodstream infections: increasing prevalence of Gram-negative pathogens.

    Science.gov (United States)

    Marcos, Miguel; Soriano, Alex; Iñurrieta, Amaia; Martínez, José A; Romero, Alberto; Cobos, Nazaret; Hernández, Cristina; Almela, Manel; Marco, Francesc; Mensa, Josep

    2011-09-01

    Gram-positive microorganisms have been the predominant pathogens in central venous catheter-related bloodstream infections (CRBSIs). Recent guidelines recommend empirical therapy according to this and restrict coverage for Gram-negatives to specific circumstances. This study aimed to analyse the epidemiological changes in CRBSIs over the 1991-2008 period and to analyse predictors of Gram-negative CRBSIs. A prospectively collected cohort of patients with confirmed CRBSIs was analysed. Strains isolated and antimicrobial susceptibility, as well as clinical and demographic variables were recorded. Differences observed during the study period were analysed by means of a χ² trend test and factors associated with Gram-negative CRBSIs by means of multivariable analysis. Between 1991 and 2008, 1129 episodes of monomicrobial CRBSIs were recorded. There was an increase in the incidence of CRBSIs, from 0.10 (1991-92) to 0.31 (2007-08) episodes/1000 patient-days. A significant increase in the number of Gram-negative strains among the total isolates was also found, from 3 (4.7%) in 1991-92 to 70 (40.23%) in 2007-08, with a parallel decrease in the percentage of Gram-positives. Solid organ transplantation, prior use of penicillins and hospital stay longer than 11 days were independently associated with a significantly higher risk of Gram-negative CRBSIs, while cirrhosis, diabetes and use of quinolones were associated with a higher risk of Gram-positives. Gram-negative strains are an increasing cause of CRBSIs, reaching a prevalence of 40% in the 2007-08 period in our hospital. If this trend is confirmed in other centres, a broad-spectrum empirical therapy should be considered in managing these infections.

  4. The effect of venous anatomy on the morphology of multiple sclerosis lesions: a susceptibility-weighted imaging study

    International Nuclear Information System (INIS)

    Öztoprak, B.; Öztoprak, İ.; Yıldız, Ö.K.

    2016-01-01

    Aim: To investigate the cause of morphology in non-ovoid multiple sclerosis (MS) lesions lacking a radial course and typical shape. Materials and methods: Non-ovoid atypical lesions without perpendicular extensions to the ventricle were investigated in 95 MS patients by retrospective examination of T2-weighted and fluid-attenuated inversion recovery (FLAIR) images. The relationship between the morphology of these atypical lesions detected in 38 patients and central vein anatomy was examined using susceptibility-weighted imaging (SWI). Results: A central venous structure was observed in 107 (65.6%) of 163 atypical lesions in 38 patients. The distribution of atypical lesions grouped by their shape was as follows: (1) V- or Y-shaped lesions (n=27, 48.6%) were observed where veins bifurcated; (2) crescent-shaped lesions (n=9, 8.4%) were observed where veins formed an arc; (3) patchy lesions comprised 48.6% (n=52) of the atypical lesions and involved multiple medullary veins or medullary veins showing a “caput medusae” distribution; (4) ovoid lesions with a non-radial course (n=19, 17.7%) were generally observed where medullary veins converged to form internal cerebral vein branches. Conclusion: Unlike typical MS plaques, non-ovoid atypical lesions make the differential diagnosis of MS challenging. Demonstration of the relationship between venous anatomy and lesion morphology in atypical lesions using SWI will aid in the differential diagnosis. - Highlights: • Morphology of MS lesions are associated with the orientation of central veins. • SWI shows venous anatomy and anatomic variations in MS lesions. • Association between vein and T2-hyperintensity may aid in differential diagnosis.

  5. The clinical application of head-ring type posture pad used for prone position in performing the placement of central venous catheter in patients with tumors

    International Nuclear Information System (INIS)

    Chen Meiqian; Wang Chunmei; Chen Feiyin; Zhang Lubing

    2011-01-01

    Objective: to observe the effectiveness of head-ring type posture pad used for prone position in performing the procedure of peripheral insertion of central catheter (PICC) via the dorsal forearm vein in patients with neoplasm. Methods: A total of 80 consecutive tumor patients were randomly divided into two groups. PICC was carried out in all patients in prone position. In control group (n=38) PICC was performed with patient's head inclining to one side, while in study group (n=42) PICC was performed with the help of head-ring type pad to keep the patient in comfortable posture. The comfortableness, breathing rhythm, transcutaneous oxygen saturation and the change of heart rate during the procedure were observed. The results were analyzed and compared between the two groups. Results: The results is study group were much better than those in control group. Statistically significant difference in the comfortableness, breathing rhythm, transcutaneous oxygen saturation and heart rate existed between the two groups. Conclusion: The head-ring type posture pad used for prone position can make the patients more comfortable in performing peripheral insertion of central venous catheter via the dorsal forearm vein. (authors)

  6. Pulmonary venous abnormalities encountered on pre ...

    African Journals Online (AJOL)

    Multidetector computed tomography (MDCT) elegantly renders pulmonary venous anatomy. With increasing numbers of radiofrequency ablation procedures being performed, there is now a greater emphasis on pre-procedure imaging to delineate this anatomy. Pulmonary venous mapping studies can be performed with or ...

  7. ENDOVASCULAR TREATMENT FOR DISORDERS OF THE VENOUS SYSTEM

    Directory of Open Access Journals (Sweden)

    A. G. Osiev

    2015-01-01

    Full Text Available The annual rate of deep vein thrombosis in general population is from 5 to 9 cases per 10 000, whereas for venous thromboembolism (deep vein thrombosis and pulmonary embolism taken together amounts to 14 cases per 10 000. To improve longterm results of therapy for thrombosis of deep veins of the lower extremities, it is important to restore venous function and outflow. Anticoagulant therapy with low weight or non-fractionated heparin preparations remains the most widely used method of management. However, total or partial thrombosis resolution under anticoagulant treatment is achieved only in 4 and 14% of cases, respectively. Thrombolysis allows for early resorption of the thrombus by means of a minimally invasive procedure with lower risk of complication. After the venous flow is restored, the aim of treatment is to prevent damage to the venous valves, venous hypertension and repeated thrombosis with development of the post-thrombotic syndrome. Compared to anticoagulation, systemic thrombolysis has the benefit of more rapid clot resorption and less damage to the venous valve. One of its serious limitations is a high bleeding risk related to higher doses of the drug administered through a peripheral vein catheter. Therefore, selective intra-clot administration of thombolytics (direct catheter thrombolysis has been suggested as an alternative. For more effective therapy with the use of lower doses of thrombolytics, the so called pharmaco-mechanical thrombectomy has been developed. Venous stenosis hindering the venous outflow is frequently seen after direct catheter or pharmaco-mechanical thrombolysis. Angioplasty with stent placement is recommended in the cases with residual venous abnormality after successful thrombolysis and thrombectomy. 

  8. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M. [University of Arkansas for Medical Sciences, Pediatric Radiology, Little Rock, AR (United States)

    2016-01-15

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  9. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    International Nuclear Information System (INIS)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M.

    2016-01-01

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  10. R[iological interventions in central venous obstructions. Dilatation, stent-implantation and thrombolysis

    International Nuclear Information System (INIS)

    Mathias, K.; Jaeger, H.; Willaschek, J.; Theophil, B.

    1998-01-01

    Purpose: Venous congestion of the superior or inferior caval system has to be considered as a medical emergency. The results of various recanalization procedures and their utility are analyzed. Patients and methods: 176 patients with superior and 28 with inferior caval obstruction were treated with Gianturco-Z (n=39) and Wall Stents (n=207) respectively. Balloon venoplasty was performed prior to stent implanation. In 27 cases, local thrombolysis with urokinase was employed. Results: Interventional procedures were succesful in 198 and without success in 6 patients. In most patients, symptoms were relieved during or early after recanalization. No major complications were found. Discussion: Balloon angioplasty with stent placement and local thrombolysis are successful in the treatment of superior and inferior caval obstruction. Self-expanding Wallstents are superior to Gianturco-Z-stents. Oncologists should be m[e familiar with this type of treatment. (orig.) [de

  11. MR findings of cerebral venous sinus thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Chang, Kee Hyun; Han, Moon Hee; Choi, Choong Gom [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To describe MR findings of cerebral venous sinus thrombosis. We reviewed 11 MR images of six patients with cerebral venous sinus thrombosis. The MR images were retrospectively analyzed in terms of location and signal intensity of the thrombi, parenchymal lesions such as hemorrhage and edema, and changes in follow up study obtained in 4 patients. The thrombus in venous sinus was visualized on MRI in all six patients. The most frequently involved sites were superior sagittal sinus(n=4) and left transverse sinus(n=4). Signal intensity of the thrombus was isointense or hyperintense on both T1- and T2-weighted images with loss of normal signal void of the sinus on all sequences in all patients. Parenchymal lesion was patients in five of six cases, manifested as local hemorrhage in three and edema in three cases(one case overlapped). Local edema seen in three patients was completely resolved on follow up study of seven to 29 days intervals. It is concluded that iso- or high signal intensity with loss of signal void in venous sinus is virtually diagnostic of venous sinus thrombosis. If there are local parenchymal lesions such as hemorrhage and/or edema of unknown causes, cerebral venous sinus thrombosis should be included in differential diagnosis.

  12. History of venous leg ulcers.

    Science.gov (United States)

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  13. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  14. Computed tomographic manifestations of abdominal and pelvic venous collaterals

    International Nuclear Information System (INIS)

    Pagani, J.J.; Thomas, J.L.; Bernardino, M.E.

    1982-01-01

    Obstruction of blood flow through the inferior vena cava and portal vein may produce venous collaterals. These include the paravertebral venous system and its communications with the ascending lumbar veins and azygous/hemiazygous system; gonadal, periureteric, and other retroperitoneal veins; abdominal wall veins; hemorrhoidal venous plexus; and the portal venous system. The anatomic location of these vessels is discussed. Computed tomography demonstrates them as round or tubular structures that are isodens when compared with other venous structures following contrast material administration. Techniques of examination and methods of differentiation of these vascular structures from other abnormalities, especially lymphadenopathy, are discussed

  15. Sex-specific aspects of venous thrombosis

    NARCIS (Netherlands)

    Roach, Rachel Elizabeth Jo

    2014-01-01

    Venous thrombosis is a disease that occurs in 1-2 per 1000 people per year. At the time of their first venous thrombosis, approximately 50% of women are exposed to reproductive risk factors (oral contraception, postmenopausal hormone therapy, pregnancy and the puerperium). In this thesis, we showed

  16. Intracranial developmental venous anomaly: is it asymptomatic?

    Science.gov (United States)

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Venous sinus stenting for pseudotumour cerebri with venous sinus stenosis

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Wu Xiaojun; Qi Xiangqian; Mei Qiyong; Lu Yicheng

    2011-01-01

    Objective: To explore the relation between venous sinus stenosis and pseduotumour cerebri and to discuss the efficacy and strategy of venous sinus stenting for its treatment. Methods: Venous sinus stenting was performed in a total of 9 patients with pseudotumour cerebri accompanied by dural sinus stenosis. The clinical data, including the clinical presentations, intracranial pressure, angiographic findings, pressure of dural sinus,methods of treatment and the therapeutic results, were retrospectively analyzed. Results: Bilateral disc edema was seen in all patients. The pressure gradient in the lateral sinuses was obviously high before stenting (22.67±7.25)mmHg in all patients and a reduction in intra-sinus pressure and pressure gradient was also found (5.78±3.77)mmHg. The symptoms associated with intracranial hypertension were gradually improved or disappeared in two weeks after the placement of the stent in all cases, and the intracranial pressure dropped evidently (12.78±5.97)cm H 2 O. Vision was improved in 7 cases at three months, whereas it remained poor in 2 cases despite normalized intracranial pressure. There was no other permanent procedure-related morbidity. The patients were followed up for 3 months to 5 years, and no recurrence developed. Conclusion: Lateral sinus stenting is an effective method for the treatment of pseudotumour cerebri with dural sinus stenosis. (authors)

  18. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    Science.gov (United States)

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  19. Inflammation and peripheral venous disease. The San Diego Population Study.

    Science.gov (United States)

    Cushman, M; Callas, P W; Allison, M A; Criqui, M H

    2014-09-02

    The inflammatory response to healing in venous thrombosis might cause vein damage and post-thrombotic syndrome. Inflammation may also be involved in venous insufficiency apart from deep-vein thrombosis. We studied the association of inflammation markers with venous insufficiency in a general population sample. We characterised 2,404 men and women in a general population cohort for peripheral venous disease and its severity using physical exam, symptom assessment, and venous ultrasound. Inflammation markers, C-reactive protein (CRP), fibrinogen, interleukin 1-beta (IL-1-beta), IL-8, IL-10, intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), E-selectin, monocyte chemoattractant-1 (MCP-1) and vascular endothelial cell growth factor (VEGF) were compared in 352 case participants with peripheral venous disease and 352 controls with no venous abnormalities frequency matched to cases by age, sex and race. Associations were also evaluated including a subset of 108 cases of severe venous disease, as previously defined. Odds ratios (95% CI), for peripheral venous disease for biomarkers in the top quartile (adjusting for age, race, sex, body mass index and history of venous thrombosis) were 1.8 (1.1-3.0), 1.6 (1.0-2.5) and 1.5 (0.9-2.3) for CRP, fibrinogen and IL-10, respectively. Associations were larger considering cases of severe venous disease, with odds ratios for these three analytes of 2.6 (1.2-5.9), 3.1 (1.3-7.3) and 2.2 (1.1-4.4), and for IL-8: 2.4 (1.1-5.2). There was no association of IL-1-beta, ICAM-1, VCAM-1, E-selectin, MCP-1 or VEGF with overall cases or severe venous disease. In conclusion, a subset of inflammation markers were associated with increased risk of peripheral venous disease, suggesting potential therapeutic targets for treatment.

  20. Clinicoroentgenological diagnosis of chronic venous ovarian insufficiency

    International Nuclear Information System (INIS)

    Grakova, L.S.; Galkin, E.V.; Naumova, E.B.

    1989-01-01

    The paper is devoted to clinicoroentgenological correlations of venous renogonadal hemodynamics in 168 women of reproductive age (151 women with infertility, habitual abortion, disordered menstrual function and 17 patients without disorders of the reproductive tract). Clinicolaboratory investigation was followed by visceral and parietal flebography for the detection of a pathological venous reflux into the ovarian pampiniform plexus. Clinicoroentgenological semiotics of chronic venous ovarian insufficiency was analyzed. Infertility was shown to be the main clinical manifestation of ovarian varicocele

  1. REVIEW ARTICLE Venous thromboembolism associated with ...

    Indian Academy of Sciences (India)

    Navya

    2017-03-24

    Mar 24, 2017 ... Venous thromboembolism associated with protein S deficiency due to ... 2 Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland ... It has been long recognized that reduced PS activity is a risk factor for venous ... 1988). Sequencing of PROS1 gene intensified studies of genotype-.

  2. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  3. Postoperative deep venous thrombosis in Japan. Incidence and prophylaxis

    International Nuclear Information System (INIS)

    Inada, K.; Shirai, N.; Hayashi, M.; Matsumoto, K.; Hirose, M.

    1983-01-01

    The incidence of postoperative deep venous thrombosis was investigated using the iodine-125-fibrinogen method in 256 patients undergoing major surgery. Deep venous thrombosis was found in 49 patients (15.3 percent), and nonfatal pulmonary embolism developed in one of seven patients in whom the thrombus extended to the popliteal vein. The same investigation was performed in 110 patients who wore a graduated compression stocking on one leg, with the other leg serving as a control. Deep venous thrombosis was found in 4 of 110 stockinged legs (3.6 percent) and in 16 of 110 control legs (14.5 percent). The incidence of deep venous thrombosis decreased significantly in patients who wore the stocking. An increase in femoral venous flow velocity was found in the stockinged legs by the Doppler method. The mean velocity of venous return by xenon-133 clearance was significantly greater in the stockinged legs than in the control legs. These findings were considered to support the efficacy of graduated compression stockings for the prevention of deep venous thrombosis

  4. Congenital Retinal Macrovessel and the Association of Retinal Venous Malformations With Venous Malformations of the Brain.

    Science.gov (United States)

    Pichi, Francesco; Freund, K Bailey; Ciardella, Antonio; Morara, Mariachiara; Abboud, Emad B; Ghazi, Nicola; Dackiw, Christine; Choudhry, Netan; Souza, Eduardo Cunha; Cunha, Leonardo Provetti; Arevalo, J Fernando; Liu, T Y Alvin; Wenick, Adam; He, Lingmin; Villarreal, Guadalupe; Neri, Piergiorgio; Sarraf, David

    2018-04-01

    Congenital retinal macrovessel (CRM) is a rarely reported venous malformation of the retina that is associated with venous anomalies of the brain. To study the multimodal imaging findings of a series of eyes with congenital retinal macrovessel and describe the systemic associations. In this cross-sectional multicenter study, medical records were retrospectively reviewed from 7 different retina clinics worldwide over a 10-year period (2007-2017). Patients with CRM, defined as an abnormal, large, macular vessel with a vascular distribution above and below the horizontal raphe, were identified. Data were analyzed from December 2016 to August 2017. Clinical information and multimodal retinal imaging findings were collected and studied. Pertinent systemic information, including brain magnetic resonance imaging findings, was also noted if available. Of the 49 included patients, 32 (65%) were female, and the mean (SD) age at onset was 44.0 (20.9) years. A total of 49 eyes from 49 patients were studied. Macrovessel was unilateral in all patients. Color fundus photography illustrated a large aberrant dilated and tortuous retinal vein in all patients. Early-phase frames of fluorescein angiography further confirmed the venous nature of the macrovessel in 40 of 40 eyes. Optical coherence tomography angiography, available in 17 eyes (35%), displayed microvascular capillary abnormalities around the CRM, which were more evident in the deep capillary plexus. Of the 49 patients with CRM, 39 (80%) did not illustrate any evidence of ophthalmic complications. Ten patients (20%) presented with retinal complications, typically an incidental association with CRM. Twelve patients (24%) were noted to have venous malformations of the brain with associated magnetic resonance imaging. Of these, location of the venous anomaly in the brain was ipsilateral to the CRM in 10 patients (83%) and contralateral in 2 patients (17%), mainly located in the frontal lobe in 9 patients (75%). Our study has

  5. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  6. Risk factors for chronic cerebrospinal venous insufficiency (CCSVI in a large cohort of volunteers.

    Directory of Open Access Journals (Sweden)

    Kresimir Dolic

    Full Text Available BACKGROUND: The role of intra- and extra-cranial venous system impairment in the pathogenesis of various vascular, inflammatory and neurodegenerative neurological disorders, as well as in aging, has not been studied in detail. Nor have risk factors been determined for increased susceptibility of venous pathology in the intra-cranial and extra-cranial veins. The aim of this study was to investigate the association between presence of a newly proposed vascular condition called chronic cerebrospinal venous insufficiency (CCSVI and environmental factors in a large volunteer control group without known central nervous system pathology. METHODS AND FINDINGS: The data were collected in a prospective study from 252 subjects who were screened for medical history as part of the entry criteria and participated in the case-control study of CCSVI prevalence in multiple sclerosis (MS patients, and then were analyzed post-hoc. All participants underwent physical and Doppler sonography examinations, and were assessed with a structured environmental questionnaire. Fullfilment of ≥ 2 positive venous hemodynamic (VH criteria on Doppler sonography was considered indicative of CCSVI diagnosis. Risk and protective factors associated with CCSVI were analyzed using logistic regression analysis. Seventy (27.8% subjects presented with CCSVI diagnosis and 153 (60.7% presented with one or more VH criteria. The presence of heart disease (p = .001, especially heart murmurs (p = .007, a history of infectious mononucleosis (p = .002, and irritable bowel syndrome (p = .005 were associated with more frequent CCSVI diagnosis. Current or previous smoking (p = .029 showed a trend for association with more frequent CCSVI diagnosis, while use of dietary supplements (p = .018 showed a trend for association with less frequent CCSVI diagnosis. CONCLUSIONS: Risk factors for CCSVI differ from established risk factors for peripheral venous diseases. Vascular

  7. Diagnosis of deep venous thrombosis by radioisotopic phlebography; Valor da flebografia radioisotopica no diagnostico da trombose venosa profunda

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Antonio Luiz de [Universidade do Rio de Janeiro (UNIRIO), RJ (Brazil)

    1993-10-01

    The author studied 20 patients with deep venous thrombosis of members (one of them attacked on both arms), from various etiologies, by mean radioisotopic phlebography, in the Vascular Diseases, Radiology and Nuclear Medicine Services of Army Central Hospital (Rio de Janeiro, Brazil) from january 1988 to june 1990. The years old was 18 to 72. The cause most frequency of deep venous thrombosis was idiopathic (seven cases 33.3%). The presence of clot by radionuclide marker in all cases, 16 observations (76.2%) in the lower members and five in the upper extremities (23.9%); 17 cases (85%) also were a conventional venography and his images were confirmed. The diagnostic of deep venous thrombosis from {sup 99m} T{sub c}MAA (macro aggregate of albumin tagged with technetium) should always de complemented by pulmonary mapping, tracking possible silent emboli. Permit as well repetitions evolutionary until daily and using in patients with history of allergy to radiologic contrast because has not complication. (author)

  8. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  9. Diagnostics of defeats of venous collectors of brain

    International Nuclear Information System (INIS)

    Timofeeva, T.V.; Polunina, I.S.; Shcherbakova, E.Ya.; Kuldakova, S.V.

    1997-01-01

    Comparative data of transcranial ultrasonic dopplerography (170 patients) and radionuclidous antroscintigraphy (124), received during diagnostics of defects of venous collectors of brain are analyzed. Five variants of defeats of venous collectors (cross, sigmoid, internal of jugular of jugular vein), but also unpaired sine (direct, confluent) are described. Received results permit to reveal interrelation of infringements of venous outflow and increase of intracranial pressure

  10. Congenital absence of infrarenal IVC and iliac venous system : Unusual collateral Pathways

    International Nuclear Information System (INIS)

    Lee, Jin Joo; Lee, Byung Hee; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    We present a case with congenital absence of the infrarenal portion of inferior vena cava and iliac venous system, showing unusual venous collaterals including the left ovarian venous collateral via parametrial venous complex, and a mesenteric-periureteric venous connection. The venous collateral pathways were demonstrated by computed tomography and venography

  11. Mechanochemical endovenous ablation and new frontiers in venous intervention

    NARCIS (Netherlands)

    Boersma, D

    2017-01-01

    Venous insufficiency of the lower extremities is a common condition and related to various symptoms, including venous ulcers. The effect of venous insufficiency on patients’ health-related quality of life is substantial and comparable with other chronic diseases such as arthritis, diabetes, and

  12. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Tarp Hansen, Anette; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  13. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  14. Systemic Venous Inflow to the Liver Allograft to Overcome Diffuse Splanchnic Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Cristian Lupascu

    2015-01-01

    Full Text Available Diffuse splanchnic venous thrombosis (DSVT, formerly defined as contraindication for liver transplantation (LT, is a serious challenge to the liver transplant surgeon. Portal vein arterialisation, cavoportal hemitransposition and renoportal anastomosis, and finally combined liver and small bowel transplantation are all possible alternatives to deal with this condition. Five patients with preoperatively confirmed extensive splanchnic venous thrombosis were transplanted using cavoportal hemitransposition (4x and renoportal anastomosis (1x. Median follow-up was 58 months (range: 0,5 to 130 months. Two patients with previous radiation-induced peritoneal injury died, respectively, 18 days and 2 months after transplantation. The three other patients had excellent long-term survival, despite the fact that two of them needed a surgical reintervention for severe gastrointestinal bleeding. Extensive splanchnic venous thrombosis is no longer an absolute contraindication to liver transplantation. Although cavoportal hemitransposition and renoportal anastomosis undoubtedly are life-saving procedures allowing for ensuring adequate allograft portal flow, careful follow-up of these patients remains necessary as both methods are unable to completely eliminate the complications of (segmental portal hypertension.

  15. Cerebrofacial venous metameric syndrome (CVMS) 3: Sturge-Weber syndrome with bilateral lymphatic/venous malformations of the mandible

    International Nuclear Information System (INIS)

    Ramli, N.; Sachet, M.; Bao, C.; Lasjaunias, P.

    2003-01-01

    We present a case of Sturge-Weber syndrome with a bilateral lymphatic/venous malformation of the mandible. Modern biology suggests an explanation for such a case. The classification of cerebrofacial venous metameric syndromes (CVMS) enables us to recognise this lesion as involving the most caudal of the cranial metamere (CVMS 3). (orig.)

  16. Imaging of head and neck venous malformations

    International Nuclear Information System (INIS)

    Flis, Christine M.; Connor, Stephen E.

    2005-01-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team. (orig.)

  17. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    Science.gov (United States)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  18. Core content for training in venous and lymphatic medicine.

    Science.gov (United States)

    Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F

    2014-10-01

    The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Chronic venous disorders

    African Journals Online (AJOL)

    The San Valentino Vascular Screening Project conducted in Italy found a ... developed healthcare systems, the cost of treating advanced venous disease ..... tissue inflammation and necrosis. Sclerosing ... and for its tributaries as an alternative.

  20. Venous Thromboembolism in Patients With Thrombocytopenia

    DEFF Research Database (Denmark)

    Bælum, Jens Kristian; Ellingsen Moe, Espen; Nybo, Mads

    2017-01-01

    BACKGROUND: Venous thromboembolism (VTE) is a frequent and potentially lethal condition. Venous thrombi are mainly constituted of fibrin and red blood cells, but platelets also play an important role in VTE formation. Information about VTE in patients with thrombocytopenia is, however, missing. O...... having thrombocytopenia with VTE seem to be safely treated with anticoagulants without increased occurrence of bleeding....

  1. A BMPy Road for Venous Development.

    Science.gov (United States)

    Goddard, Lauren M; Kahn, Mark L

    2017-09-11

    Detailed molecular pathways for the specific growth of arteries and lymphatic vessels have been identified, but the mechanisms controlling venous vessel growth have been obscure. Tischfield and colleagues (2017) shed new light on this problem by identifying a role for BMP signaling in development of the cerebral venous system. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Improving venous leg ulcer management

    OpenAIRE

    Weller, Carolina Dragica

    2017-01-01

    This thesis reports several different methods to develop and evaluate complex interventions designed to improve venous leg ulcer management. Chronic venous leg ulcers (VLU) are the most common chronic wound problem in the community. Its health and economic burden is predicted to increase due to ageing of the community and increase in prevalence of diabetes and obesity. Although many patients seek health care for VLU, most do not receive the most effective management. Patients with this condi...

  3. Compression therapies for chronic venous leg ulcers: interventions and adherence

    Directory of Open Access Journals (Sweden)

    Latz CA

    2015-01-01

    Full Text Available Christopher A Latz,1 Kellie R Brown,2 Ruth L Bush11Texas A&M Health Science Center College of Medicine, Bryan, TX, USA; 2Medical College of Wisconsin, Milwaukee, WI, USAAbstract: Compression therapy has been the mainstay for the treatment of lower extremity edema, venous insufficiency, and particularly, venous ulcerative disease. Though modern surgical treatments exist, none are completely effective without good compressive options to allow for decreased swelling and better oxygenation of damaged tissues. This review article will describe the pathophysiology and presentation of lower extremity venous ulcerations, as well as current options for compression therapy. The benefits, along with the major pitfall of nonadherence, will also be discussed.Keywords: venous disease, chronic venous insufficiency, venous ulceration

  4. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  5. Venous compression syndrome of internal jugular veins prevalence in patients with multiple sclerosis and chronic cerebro-spinal venous insufficiency.

    Science.gov (United States)

    Mandolesi, Sandro; Niglio, Tarcisio; Orsini, Augusto; De Sio, Simone; d'Alessandro, Alessandro; Mandolesi, Dimitri; Fedele, Francesco; d'Alessandro, Aldo

    2016-01-01

    Analysis of the incidence of Venous Compression Syndrome (VCS) with full block of the flow of the internal jugular veins (IJVs) in patients with Multiple Sclerosis and Chronic cerebro-spinal venous insufficiency. We included 769 patients with MS and CCSVI (299 males, 470 females) and 210 controls without ms and ccsvi (92 males, 118 females). each subject was investigated by echo-color-doppler (ecd). morphological and hemodynamic ecd data were recorded by a computerized mem-net maps of epidemiological national observatory on ccsvi and they were analyzed by mem-net clinical analysis programs. VCS of IJVs occurs in 240 subjects affected by CCSVI and MS (31% of total) and in 12 controls (6% of total). The differences between the two groups are statistical significant (X² = 36.64, pCerebro-Spinal Venous Insufficiency, Multiple Sclerosis, Venous Compression Syndrome.

  6. Inner-ear circulation in humans is disrupted by extracranial venous outflow strictures: Implications for Ménière’s disease

    Directory of Open Access Journals (Sweden)

    Eleuterio F. Toro

    2018-02-01

    Full Text Available Ménière’s disease (MD is a pathology of the inner ear, the symptoms of which include tinnitus, vertigo attacks, fluctuating hearing loss, and nausea. Neither cause nor cure are currently known, though animal experiments suggest that disruption of the inner ear circulation, including venous hypertension and endolymphatic hydrops, to be hallmarks of the disease. Recent evidence for humans suggests a potential link to strictures in the extracranial venous outflow routes. The purpose of the present work is to demonstrate that the inner-ear circulation in humans is disrupted by extracranial venous outflow stricture and to discuss the implications of this finding for MD. The hypothesis linking extracranial venous outflow strictures to the altered dynamics of central nervous system (CNS fluid compartments is investigated theoretically via a global, closed-loop, multiscale mathematical model for the entire human circulation, interacting with the brain parenchyma and cerebrospinal fluid (CSF. The fluid dynamics model for the full human body includes submodels for the heart, pulmonary circulation, arterial system, microvasculature, venous system and the CSF, with a specially refined description of the inner ear vasculature. We demonstrate that extracranial venous outflow strictures disrupt inner ear circulation, and more generally, alter the dynamics of fluid compartments in the whole CNS. Specifically, as compared to a healthy control, the computational results from our model show that subjects with extracranial outflow venous strictures exhibit: altered inner ear circulation, redirection of flow to collaterals, increased intracranial venous pressure and increased intracranial pressure. Our findings are consistent with recent clinical evidence in humans that links extracranial outflow venous strictures to MD, aid the mechanistic understanding of the underlying features of the disease and lend support to recently proposed biophysically motivated

  7. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  8. Cerebral sino-venous thrombosis

    International Nuclear Information System (INIS)

    Sayama, Ichiro; Kobayashi, Tsunesaburo; Nakajima, Kenji

    1982-01-01

    Three cases of cerebral sino-venous thrombosis were reported. Repeated CT findings were studied and discussed on account of the treatments for those pathologic conditions. Those of studied cases are; a 22-year-old postpartum woman, a 42-year-old woman with irregular vaginal bleeding, and a 26-year-old man with severe reactive emesis after drinking alcohol. They were treated conservatively. Case 1 died in its acute stage. In the remaining ones, each had an uneventful recovery. CT scan findings of them manifested their exact clinical conditions. These findings were devided into two categories, one was direct signs expressed sino-venous occlusion, the other was indirect signs which appeared as a result of these occlusion. Direct signs cannot always get in every cases with sino-venous occlusion, but as for indirect signs, we can get various changes corresponding to the time taken CT photoes, and they are useful to decide appropriate treatments at that time. Considering suitable treatments for this disease, it is necessary to select most suitable ones according to their pathologic conditions, which may be precisely drawn with CT scans. (J.P.N.)

  9. Comparison of Two Central Venous Pressure Control Strategies to Prevent Atrial Fibrillation After Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Mario Augusto Cray da Costa

    Full Text Available Abstract Background: Atrial fibrillation (AF takes place in 10-40% of patients undergoing coronary artery bypass grafting (CABG, and increases cardiovascular mortality. Enlargement of atrial chambers is associated with increased AF incidence, so patients with higher central venous pressure (CVP are expected to have larger atrial distension, which increases AF incidence. Objective: To compare post-CABG AF incidence, following two CVP control strategies. Methods: Interventional, randomized, controlled clinical study. The sample comprised 140 patients undergoing CABG between 2011 and 2015. They were randomized into two groups, G15 and G20, with CVP maintained ≤ 15 cmH2O and ≤ 20 cmH2O, respectively. Results: 70 patients were included in each group. The AF incidence in G15 was 8.57%, and in G20, 22.86%, with absolute risk reduction of 14.28%, and number needed to treat (NNT of 7 (p = 0.03. Mortality (G15 = 5.71%; G20 = 11.42%; p = 0.07, hospital length of stay (G15 = 7.14 days; G20 = 8.21 days; p = 0.36, number of grafts (median: G15 = 3, G2 = 2; p = 0.22 and cardiopulmonary bypass use (G15 = 67.10%; G20 = 55.70%; p = 0.22 were statistically similar. Age (p = 0.04 and hospital length of stay (p = 0.001 were significantly higher in patients who developed AF in both groups. Conclusion: Keeping CVP low in the first 72 post-CABG hours reduces the relative risk of AF, and may be useful to prevent AF after CABG.

  10. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    International Nuclear Information System (INIS)

    Guo, Xin-bin; Fu, Zhenqiang; Song, Lai-jun; Guan, Sheng

    2013-01-01

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH 2 O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period

  11. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    In the clinical setting, diagnosis and treatment of venous leg ulcers can vary considerably from patient to patient. The first step to reducing this variation is to document venous leg ulcer care through use of quantitative scientific documentation principles. This requires the development of val...

  12. Risk factors for venous thromboembolism during pregnancy

    DEFF Research Database (Denmark)

    Jensen, Thomas Bo; Gerds, Thomas Alexander; Grøn, Randi

    2013-01-01

    Pregnant women are at an increased risk of venous thromboembolism (VTE). Risk factors for VTE among pregnant women are not sufficiently investigated.......Pregnant women are at an increased risk of venous thromboembolism (VTE). Risk factors for VTE among pregnant women are not sufficiently investigated....

  13. Embracing Errors in Simulation-Based Training: The Effect of Error Training on Retention and Transfer of Central Venous Catheter Skills.

    Science.gov (United States)

    Gardner, Aimee K; Abdelfattah, Kareem; Wiersch, John; Ahmed, Rami A; Willis, Ross E

    2015-01-01

    Error management training is an approach that encourages exposure to errors during initial skill acquisition so that learners can be equipped with important error identification, management, and metacognitive skills. The purpose of this study was to determine how an error-focused training program affected performance, retention, and transfer of central venous catheter (CVC) placement skills when compared with traditional training methodologies. Surgical interns (N = 30) participated in a 1-hour session featuring an instructional video and practice performing internal jugular (IJ) and subclavian (SC) CVC placement with guided instruction. All interns underwent baseline knowledge and skill assessment for IJ and SC (pretest) CVC placement; watched a "correct-only" (CO) or "correct + error" (CE) instructional video; practiced for 30 minutes; and were posttested on knowledge and IJ and SC CVC placement. Skill retention and transfer (femoral CVC placement) were assessed 30 days later. All skills tests (pretest, posttest, and transfer) were videorecorded and deidentified for evaluation by a single blinded instructor using a validated 17-item checklist. Both the groups exhibited significant improvements (p error-based activities and discussions into training programs can be beneficial for skill retention and transfer. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    Science.gov (United States)

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  15. Mesenteric venous thrombosis after prolonged air travel-a case report

    Directory of Open Access Journals (Sweden)

    Joaquín Salas-Coronas

    2014-07-01

    Full Text Available We present a case of acute mesenteric venous thrombosis after a long distance flight in a traveller presenting with abdominal pain, diarrhoea and vomiting within 48 h of prolonged immobility situation. Venous thrombosis in the lower limbs and venous thromboembolism has been clearly associated with prolonged air travel (economy class syndrome. Thrombosis was diagnosed by computed tomography of the abdomen, and after starting anticoagulant therapy with acenocumarol, symptoms yielded completely in a few weeks. The study of thrombophilia was negative, although the existence of two first-degree relatives (mother and grandmother with a history of venous thrombosis with a history of venous thrombosis makes it likely a situation of inherited thrombophilia. Although exceptional, mesenteric venous thrombosis should be considered in travellers with acute abdominal pain after prolonged air travel when there are thrombophilic conditions.

  16. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xin-bin, E-mail: gxb3906080@sina.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Fu, Zhenqiang, E-mail: fuzhenqiang1005@163.com [Department of Neurology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Song, Lai-jun, E-mail: laijunsong@sina.com [Department of Neurosurgery, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Guan, Sheng, E-mail: gsradio@126.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China)

    2013-01-15

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH{sub 2}O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period.

  17. Antiseptic barrier cap effective in reducing central line-associated bloodstream infections : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Voor In 't Holt, Anne F; Helder, Onno K; Vos, Margreet C; Schafthuizen, Laura; Sülz, Sandra; van den Hoogen, Agnes; Ista, Erwin

    2017-01-01

    BACKGROUND: Microorganisms can intraluminally access a central venous catheter via the catheter hub. The catheter hub should be appropriately disinfected to prevent central line-associated bloodstream infections (CLABSIs). However, compliance with the time-consuming manual disinfection process is

  18. [Emphysematous gastritis with concomitant portal venous air].

    Science.gov (United States)

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  19. [Venous thromboembolic disease: presentation of a case].

    Science.gov (United States)

    Mirpuri-Mirpuri, P G; Álvarez-Cordovés, M M; Pérez-Monje, A

    2013-01-01

    Venous thromboembolic disease in its clinical spectrum includes both deep vein thrombosis and pulmonary thromboembolism, which is usually a complication of deep vein thrombosis. It is a relatively common disease with significant morbidity and requires an accurate diagnosis. They are numerous risk factors for venous thromboembolism, and there is evidence that the risk of thromboembolic disease increases proportionally to the number of predisposing risk factors present. The primary care physician should know the risk factors and suspect the presence of venous thromboembolic disease when there is a compatible clnical picture. The treatment for this pathology is anticoagulation. We report a patient with cardiovascular risk factors who was seen with pain in the right leg and shortness of breath and referred to the hospital with suspected venous thromboembolism, atrial fibrillation and pleural effusion. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  20. Evaluation of risk factors for thrombophilia in patients with cerebral venous thrombosis.

    Science.gov (United States)

    Yokuş, Osman; Şahin Balçık, Özlem; Albayrak, Murat; Ceran, Funda; Dağdaş, Simten; Yılmaz, Mesude; Özet, Gülsüm

    2010-09-05

    The increased risk for thrombosis is known as hypercoagulability or thrombophilia. In our study, we aimed to compare the frequency of the identified defects for thrombophilia in patients with central venous thrombosis and under the age of 50 years, with the findings in the current literature. Forty-three patients (16-50 years old) were retrospectively evaluated. Thrombophilia investigation included determinations of protein C, protein S, antithrombin, and activated protein C resistance, factor V Leiden (FVL), prothrombin 20210A (PT 20210) and methylene tetrahydrofolate reductase (MTHFR) C677T mutations, antiphospholipid antibodies (APA), factor VIII levels, and homocysteine levels. We detected a single thrombophilic defect in 67.4%, two defects in 27.9% and three defects in 4.7% of our patients. The most common thrombophilic defect was mutation in the MTHFR gene (41.8%), and this was followed by the FVL mutation (34.9%). Since the prevalence of individual thrombophilic defects varies in each population, ethnic group and geographical location, screening for thrombophilic defects in patients presenting with cerebral venous thrombosis should primarily investigate the most frequent thrombophilia risk factors.

  1. Greece reports prototype intervention with first peripherally inserted central catheter: case report and literature review.

    Science.gov (United States)

    Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios

    2012-09-01

    Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.

  2. Pathophysiology of spontaneous venous gas embolism

    Science.gov (United States)

    Lambertsen, C. J.; Albertine, K. H.; Pisarello, J. B.; Flores, N. D.

    1991-01-01

    The use of controllable degrees and durations of continuous isobaric counterdiffusion venous gas embolism to investigate effects of venous gas embolism upon blood, cardiovascular, and respiratory gas exchange function, as well as pathological effects upon the lung and its microcirculation is discussed. Use of N2O/He counterdiffusion permitted performance of the pathophysiologic and pulmonary microstructural effects at one ATA without hyperbaric or hypobaric exposures.

  3. Iliofemoral and iliocaval interventions in deep venous thrombosis

    International Nuclear Information System (INIS)

    Haage, P.; Guenther, R.W.

    2005-01-01

    Significant spontaneous thrombus disintegration in deep venous thrombosis (DVT) occurs very infrequently. On the contrary, these thrombi are prone to appositional growth and migration into the pulmonary arteries. The development of chronic venous insufficiency due to post-thrombotic syndrome is a frequent consequence of DVT. Therapeutic options in DVT include anticoagulation and recanalising procedures such as thrombolysis and thrombectomy. After appropriate indication assessment, the interventional radiologist can offer an efficacy-proven minimally-invasive vessel restitution approach by performing locoregional thrombolysis, pharmacomechanical therapy or, particularly in iliocaval thrombosis, mechanical thrombectomy. These methods not only serve to restitute of vessel patency, but also allow preserving venous valve function. In DVT with recurrent pulmonary embolism, retrievable filters with extended implantation duration can be deployed. In chronic proximal venous flow obstruction or in case of significant residual stenosis after thrombolysis, balloon angioplasty with stent implantation is the treatment modality of choice. Consequently, the radiologist can adopt an important role in the treatment of extensive venous disease. In this article, the treatment modalities concerning iliofemoral and iliocaval thrombosis are demonstrated and illustrated. (orig.)

  4. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation.

    Science.gov (United States)

    Shelley, Kirk H; Tamai, Doris; Jablonka, Denis; Gesquiere, Michael; Stout, Robert G; Silverman, David G

    2005-03-01

    Reflective forehead pulse oximeter sensors have recently been introduced into clinical practice. They reportedly have the advantage of faster response times and immunity to the effects of vasoconstriction. Of concern are reports of signal instability and erroneously low Spo(2) values with some of these new sensors. During a study of the plethysmographic wave forms from various sites (finger, ear, and forehead) it was noted that in some cases the forehead wave form became unexpectedly complex in configuration. The plethysmographic signals from 25 general anesthetic cases were obtained, which revealed the complex forehead wave form during 5 cases. We hypothesized that the complex wave form was attributable to an underlying venous signal. It was determined that the use of a pressure dressing over the sensor resulted in a return of a normal plethysmographic wave form. Further examination of the complex forehead wave form reveal a morphology consistent with a central venous trace with atrial, cuspidal, and venous waves. It is speculated that the presence of the venous signal is the source of the problems reported with the forehead sensors. It is believed that the venous wave form is a result of the method of attachment rather than the use of reflective plethysmographic sensors.

  5. Emulsifiers' composition modulates venous irritation of the nanoemulsions as a lipophilic and venous irritant drug delivery system.

    Science.gov (United States)

    Mao, Chengwen; Wan, Jiangling; Chen, Huabing; Xu, Huibi; Yang, Xiangliang

    2009-01-01

    In this study, a nanoemulsion (NE) system was investigated for intravenous delivery of lipophilic and venous irritant drugs. NEs were prepared to deliver diallyl trisulfide (DT) for systemic therapy of bacterial and fungal infection, egg phospholipid was chosen as the main emulsifier, and two co-emulsifiers were also incorporated, including Poloxamer 188 (P188) and Solutol HS 15 (S15). Soybean oil was used as the dispersed phases, forming stable DT NEs with small particle sizes. The venous irritation of DT NEs was evaluated by in vitro human umbilical cord endothelial cells (CRL 1730) compatibility model with the intracellular adenosine triphosphate (ATP) and guanosine triphosphate (GTP) concentrations as the indices. The intracellular ATP and GTP reduction changed with the incorporation of a variety of co-emulsifiers, which varied in a free DT concentration-dependent manner. It was deduced that the free DT concentrations of NEs containing co-emulsifiers were determined by the partition coefficient of DT between oil and surfactant buffer solution. In conclusion, NE was an appropriate delivery system for lipophilic and venous irritant drug, and optimization of the composition of emulsifiers was an effective method to alleviate the venous irritation of DT NEs.

  6. Pericardial effusion with cardiac tamponade caused by a central ...

    African Journals Online (AJOL)

    With more and more extreme premature and very low-birth weight babies being resuscitated, umbilical central venous catheterisation is now being used more frequently in neonatal intensive care. One of the life-threatening complications is pericardial effusion and cardiac tamponade; however, it is potentially reversible ...

  7. Cerebral venous angioma

    International Nuclear Information System (INIS)

    Inagawa, Tetsuji; Taguchi, Haruyoshi; Kamiya, Kazuko; Yano, Takashi; Nakajima, Reiko

    1984-01-01

    This report presents a 27-year-old male patient who was diagnosed as having cerebral venous angioma in the postero-temporal area by CT scan and cerebral angiography. The patient improved by removing angioma with electrocoagulation of medullary veins. (Namekawa, K.)

  8. Reduced central blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Bendtsen, F; Henriksen, Jens Henrik Sahl; Sørensen, T I

    1989-01-01

    than 0.0001). The lowest values (18 ml/kg) were found in patients with gross ascites and a reduced systemic vascular resistance. In patients with cirrhosis central blood volume was inversely correlated to the hepatic venous pressure gradient (r = -0.41, p less than 0.01), and the total blood volume...... was inversely correlated to the systemic vascular resistance (r = -0.49, p less than 0.001), the latter being significantly reduced in the patient group. Patients with cirrhosis apparently are unable to maintain a normal central blood volume. This may be due to arteriolar vasodilation, portosystemic collateral...

  9. Venous ulcers of the lower limb: Where do we stand?

    Directory of Open Access Journals (Sweden)

    Chatterjee S Sasanka

    2012-01-01

    Full Text Available Venous ulcers are the most common ulcers of the lower limb. It has a high morbidity and results in economic strain both at a personal and at a state level. Chronic venous hypertension either due to primary or secondary venous disease with perforator paucity, destruction or incompetence resulting in reflux is the underlying pathology, but inflammatory reactions mediated through leucocytes, platelet adhesion, formation of pericapillary fibrin cuff, growth factors and macromolecules trapped in tissue result in tissue hypoxia, cell death and ulceration. Duplex scan with colour flow is the most useful investigation for venous disease supplying information about patency, reflux, effects of proximal and distal compression, Valsalva maneuver and effects of muscle contraction. Most venous disease can be managed conservatively by leg elevation and compression bandaging. Drugs of proven benefit in venous disease are pentoxifylline and aspirin, but they work best in conjunction with compression therapy. Once ulceration is chronic or the patient does not respond to or cannot maintain conservative regime, surgical intervention treating the underlying venous hypertension and cover for the ulcer is necessary. The different modalities like sclerotherapy, ligation and stripping of superficial varicose veins, endoscopic subfascial perforator ligation, endovenous laser or radiofrequency ablation have similar long-term results, although short-term recovery is best with radiofrequency and foam sclerotherapy. For deep venous reflux, surgical modalities include repair of incompetent venous valves or transplant or transposition of a competent vein segment with normal valves to replace a post-thrombotic destroyed portion of the deep vein.

  10. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  11. 3D gadolinium-enhanced MRI venography: Evaluation of central chest veins and impact on patient management

    International Nuclear Information System (INIS)

    Oxtoby, J.W.; Widjaja, E.; Gibson, K.M.; Uzoka, K.

    2001-01-01

    AIM: To assess the value of a simplified 3D gadolinium-enhanced magnetic resonance imaging (MRI) venography for central chest veins. MATERIALS AND METHODS: In this retrospective study of 24 patients, the MRI findings and medical records were reviewed to determine whether MRI results correlated with subsequent findings, and to determine the effect on clinical management. 3D steady state gradient-echo sequence, fast imaging with steady state precession (FISP), was used. We employed a simplified protocol not requiring bolus timing or subtraction to achieve rapid data acquisition and hence good compliance in this group of frail patients. Following intravenous administration of a bolus of gadolinium, two acquisitions were obtained in order to ensure adequate opacification of all veins. Individual partitions and maximum intensity projections were then analysed to determine whether the veins were patent, stenosed or occluded. RESULTS: The indications for MRI were to assess the patency of central veins for the purpose of cannulation or arteriovenous fistula formation in 17 patients. Out of the 12 patients who proceeded to an intervention, MRI venography successfully predicted an appropriate site in 10 patients. In the remaining seven patients, MRI venography was valuable in confirming or excluding the clinical suspicion of central venous thrombosis and directly influenced the management in five patients. CONCLUSION: 3D gadolinium-enhanced MRI venography is a valuable means of providing a global representation of the central venous system and guiding subsequent central venous cannulation. Oxtoby, J.W. et al. (2001)

  12. The Role of Inflammation in Venous Thromboembolism

    Directory of Open Access Journals (Sweden)

    Brian R. Branchford

    2018-05-01

    Full Text Available Venous thromboembolism (VTE, comprising deep vein thrombosis (DVT, and pulmonary embolism (PE, is becoming increasingly recognized as a cause of morbidity and mortality in pediatrics, particularly among hospitalized children. Furthermore, evidence is accumulating that suggests the inflammatory response may be a cause, as well as consequence, of VTE, but current anticoagulation treatment regimens are not designed to inhibit inflammation. In fact, many established clinical VTE risk factors such as surgery, obesity, cystic fibrosis, sepsis, systemic infection, cancer, inflammatory bowel disease, and lupus likely modulate thrombosis through inflammatory mediators. Unlike other traumatic mechanisms of thrombosis involving vascular transection and subsequent exposure of subendothelial collagen and other procoagulant extracellular matrix materials, inflammation of the vessel wall may initiate thrombosis on an intact vein. Activation of endothelial cells, platelets, and leukocytes with subsequent formation of microparticles can trigger the coagulation system through the induction of tissue factor (TF. Identification of biomarkers to evaluate VTE risk could be of great use to the clinician caring for a patient with inflammatory disease to guide decisions regarding the risk:benefit ratio of various types of potential thromboprophylaxis strategies, or suggest a role for anti-inflammatory therapy. Unfortunately, no such validated inflammatory scoring system yet exists, though research in this area is ongoing. Elevation of C-reactive protein, IL-6, IL-8, and TNF-alpha during a response to systemic inflammation have been associated with increased VTE risk. Consequent platelet activation enhances the prothrombotic state, leading to VTE development, particularly in patients with other risk factors, most notably central venous catheters.

  13. Venous leg ulcers

    Science.gov (United States)

    2008-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri

  14. Cerebral Venous Thrombosis Revealing Primary Sjögren Syndrome: Report of 2 Cases

    Directory of Open Access Journals (Sweden)

    A. Mercurio

    2013-01-01

    Full Text Available Sjögren syndrome (SS is an autoimmune disease of the exocrine glands, characterized by focal lymphocytic infiltration and destruction of these glands. Neurologic complications are quite common, mainly involving the peripheral nervous system (PNS. The most common central nervous system (CNS manifestations are myelopathy and microcirculation vasculitis. However, specific diagnostic criteria for CNS SS are still lacking. We report two cases of primary SS in which the revealing symptom was cerebral venous thrombosis (CVT in the absence of genetic or acquired thrombophilias.

  15. Anatomical features of venous outflow from rat’s reproductive organs

    Directory of Open Access Journals (Sweden)

    N. A. Nikitin

    2012-01-01

    Full Text Available The venous drainage from reproductive organs of rats is described; new data on peculiarities of the venous drainage are obtained.Objects of study were adult Wistar white rats (20 animals. The animals have passed precision dissection of vessels in order to study anatomic peculiarities of venous drainage from the left spermary in male rats and internal genital organs in female rats in norm. It has been shown that the venous drainage from the left spermary follows the spermatic vein entering into the pampiniform plexus system, which continues into the single venous trunk, which, in its turn, divides into the ascending and descending veins. The descending vein runs into the common left iliac vein, while the ascending vein runs into the renal vein. The venous drainage from female reproductive organs follows through the uterine vein, which, taking the tubal and spermatic veins, runs from the left into the left renal vein and from the right into the caudal vena cava.

  16. Saturação venosa central e mista de oxigênio no choque séptico: existe diferença clinicamente relevante? Central and mixed venous oxygen saturation in septic shock: is there a clinically relevant difference?

    Directory of Open Access Journals (Sweden)

    Flavia Ribeiro Machado

    2008-12-01

    Full Text Available INTRODUÇÃO: A medida da saturação venosa central de oxigênio (SvcO2 tem sido proposta como alternativa a saturação venosa mista (SvO2, com grau de concordância variável nos dados atualmente disponíveis. Esse estudo objetivou avaliar as possíveis diferenças entre a SvO2 e a SvcO2 ou saturação venosa atrial de oxigênio (SvaO2, com ênfase na interferência do débito cardíaco, e o impacto delas no manejo clínico do paciente séptico. MÉTODOS: Estudo prospectivo observacional em pacientes com choque séptico monitorizados com cateter de artéria pulmonar. Foi obtido sangue simultaneamente para determinação da SvcO2, SvO2 e SvaO2. Realizado testes de correlação linear (significativos se pINTRODUCTION: Central venous oxygen saturation (SvcO2 has been proposed as an alternative for mixed venous oxygen saturation (SvO2, with a variable level of acceptance according to available data. This study aimed to evaluate possible differences between SvO2 and SvcO2 or atrial venous saturation (SvaO2, with emphasis on the role of cardiac output and their impact on clinical management of the septic patient. METHODS: This is an observational, prospective study of patients with septic shock monitored by pulmonary artery catheter. Blood was obtained simultaneously for SvcO2, SvO2 and SvaO2 determination. Linear correlation (significant if p<0.05 and agreement analysis (Bland-Altman were performed with samples and subgroups according to cardiac output. Moreover, agreement about clinical management based on these samples was evaluated. RESULTS: Sixty one measurements from 23 patients were obtained, median age of 65.0 (49.0-75.0 years and mean APACHE II of 27.7±6.3. Mean values of SvO2, SvcO2 and SvaO2 were 72.20±8.26%, 74.61±7.60% and 74.64±8.47%. Linear correlation test showed a weak correlation between SvO2 and SvcO2 (r=0.61, p<0.0001 and also between SvO2 and SvaO2 (r=0.70, p<0.0001. Agreements between SvcO2/SvO2 and SvaO2/SvO2 were -2.40

  17. Contribution of MRI in supracardiac total anomalous pulmonary venous drainage

    International Nuclear Information System (INIS)

    Kastler, B.; Germain, P.; Gangi, A.; Klinkert, A.; Dietemann, J.L.; Wackenheim, A.; Livolsi, A.; Willard, D.

    1992-01-01

    A case of supracardiac total anomalous pulmonary venous drainage (TAPVD) in an infant aged 2 1/2 months is presented. Diagnosis was established non invasively by magnetic resonance image (MRI). Not only did MRI precisely depict the anomalous venous pathway but it moreover securely excluded pulmonary venous obstruction. (orig.)

  18. Partial anomalous pulmonary venous return in Turner syndrome.

    Science.gov (United States)

    van den Hoven, Allard T; Chelu, Raluca G; Duijnhouwer, Anthonie L; Demulier, Laurent; Devos, Daniel; Nieman, Koen; Witsenburg, Maarten; van den Bosch, Annemien E; Loeys, Bart L; van Hagen, Iris M; Roos-Hesselink, Jolien W

    2017-10-01

    The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients. Copyright © 2017. Published by Elsevier B.V.

  19. A survey of current practice of vascular surgeons in venous disease management.

    Science.gov (United States)

    Bush, Ruth L; Gloviczki, Peter

    2013-01-01

    Acute venous thromboembolism and chronic venous diseases are common conditions that affect a large proportion of the United States population. The diagnosis of venous disease has improved, and the treatment options have rapidly evolved over the past decade. To date, it is unclear to what extent vascular surgeons have become involved in the modern management of venous disorders. This survey was undertaken to explore the current interest and practice of vascular surgeons in the contemporary care of venous disease. A survey was administered via a web-based platform to active and candidate members of the Society for Vascular Surgery (SVS). The survey included 30 questions investigating the characteristics of venous surgeons and scope of venous practice. Open-ended questions were also included for commentary. A total of 1879 surveys were sent to SVS members nationwide, and 385 members participated (response rate of 20.5%). The participants were mostly men (89.6%) with 37.7% practicing in an academic setting and 59.2% in private practice. The respondents treated superficial veins (92.9%) and deep veins (85.8%) in clinical practice, with 89.9% having their own vascular laboratory. A wide spectrum of interventions for superficial (91.9%), deep (85.8%), and perforator veins (52.7% endovenous, 19.4% subfascial endoscopic perforator surgery) are being performed by respondents. Only 26.2% had learned endovenous thermal ablation in their training program; however, over 96% of those performing venous interventions utilized this technique. Overall, the majority (85.5%) devoted 50% or less of practice to venous disorders. Respondents indicated that limitations to expansion of vein practices mainly involved challenges with third party payers, local competition, and existing large volumes of arterial interventions needing to be performed. Despite the widespread incorporation of venous disease into current vascular practices, 66.1% are not members of the American Venous Forum (AVF

  20. [Superficial venous thrombosis. A state of art].

    Science.gov (United States)

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception

  1. Venous function after pharmacomechanical thrombolysis for extensive iliofemoral deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Wim Greeff

    2017-08-01

    Full Text Available Background: Chronic venous insufficiency is an important complication following iliofemoral deep venous thrombosis. Early thrombus removal may preserve venous function and prevent this complication. This study represents the largest reported South African series of pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis to date. Objective: To evaluate the long-term outcome following pharmacomechanical thrombolysis for proximal and extensive deep venous thrombosis in a private, specialist vascular unit. Methods: All patients who underwent pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis between August 2009 and January 2016 were invited to return for clinical assessment and venous ultrasound. Clinical findings were recorded according to the Villalta score and clinical, etiology, anatomic and pathology (CEAP classification. The quality of life (QoL was assessed utilising the VEINES-QoL/Sym questionnaire, providing two scores per patient, one describing the QoL and the other symptom severity (Sym. Results: Thirty two patients (35 legs were evaluated. There were 25 females and 7 males, with a mean age of 33.5 years (±14 years. The mean follow-up period was 31 months (range 3 months – 80 months. Results of the CEAP classification were C0 = 24 (75%, C1 = 1 (4%, C2 = 2 (6%, C3 = 2 (6% and C4 = 3 (9%. Thirty-one (97% patients had Villalta scores from 0 to 4, indicating no or mild evidence of venous disease. One patient (3% had a Villalta score of 6, indicating post-thrombotic syndrome. The mean QoL score was 87% (±12 and the mean Sym score was 86% (±14. Twenty-four (75% patients had no abnormality on ultrasound, with fibrosis the most observed abnormality. Conclusion: Most patients who had undergone pharmacomechanical thrombolysis for extensive iliofemoral deep venous thrombosis showed few significant clinical signs of chronic venous insufficiency, had excellent function on venous ultrasound and reported

  2. The Essentials of Parathyroid Hormone Venous Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology, NYU School of Medicine (United States); Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology (United States); Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu [Beth Israel Deaconess Medical Center, Department of Interventional Radiology (United States); Oklu, Rahmi, E-mail: oklu.rahmi@mayo.edu [Mayo Clinic, Department of Interventional Radiology (United States); Deipolyi, Amy, E-mail: deipolya@mskcc.org [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States)

    2017-01-15

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

  3. Use of vertebral body units to locate the cavoatrial junction for optimum central venous catheter tip positioning.

    Science.gov (United States)

    Song, Y G; Byun, J H; Hwang, S Y; Kim, C W; Shim, S G

    2015-08-01

    Central venous catheter (CVC) placement plays an important role in clinical practice; however, optimal positioning of the CVC tip remains a controversial issue. The objective of this study was to evaluate the use of vertebral body unit (VBUs), to locate the cavoatrial junction (CAJ), for optimal CVC tip placement based on chest radiography (CXR) using the carina as a landmark. 524 patients who underwent coronary computed tomographic angiography (CTA) and CXR were included. The position of the CAJ was identified using VBUs, and the efficacy of VBUs for locating the CAJ with the carina as a landmark was analysed using multiple regression analysis. A VBU was defined as the distance between two adjacent vertebral bodies, including the inter-vertebral disk space. The mean (sd) distance from the carina to the superior CAJ was 54.3 (9.7) mm on CTA; the mean distance in VBUs at the level of the carina was 21.4 (1.7) mm on CTA and 22.6 (2.1) mm on CXR. The mean CAJ position was 2.5 VBUs below the carina on CTA and 2.4 VBUs below on CXR with 95% limits of agreement between -0.6 and +0.3. The position of the CVC tip in relation to the carina can be described using the thoracic spine as an internal ruler, and the position of the CAJ in adults was reliably estimated to be 2.4 VBUs below the carina. KCT0001319. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. MRI in venous thromboembolic disease

    International Nuclear Information System (INIS)

    Sostman, H.D.; Debatin, J.F.; Spritzer, C.E.; Coleman, R.E.; Grist, T.M.; MacFall, J.R.

    1993-01-01

    We evaluated the ability of magnetic resonance (MR) imaging to detect deep venous thrombosis (DVT) and pulmonary embolism (PE). MR venography was performed on 217 patients suspected of having DVT. Cine-MR imaging of the pulmonary arteries was performed in 14 other patients who were thought to have PE based on other imaging studies. In a third group of 5 patients, MR pulmonary angiograms were performed in the sagittal and coronal planes with a multislice fast gradient recalled echo technique. All but one of the 217 MR venograms were technically adequate. In 72 patients with correlative imaging studies (venography and ultrasound) MR venography was 99% sensitive and 95% specific. On the basis of follow-up (mean 8.3 months), no false-negative MR venograms were detected in an additional 64 patients. In 11 other patients MR revealed a diagnosis other than DVT. Cine-MR showed PE in all 14 patients evaluated. MR pulmonary arteriography demonstrated filling defects consistent with acute PE in 2 of 3 patients with acute PE; in the third patient only a questionable filling defect was seen. Coarctations or webs were found in the pulmonary arteries of both patients with chronic PE. These preliminary data suggest that MR imaging may be able to evaluate both the peripheral venous and the pulmonary arterial component of venous thromboembolic disease. Further technical refinement and more extensive clinical experience will be required to establish the role of this method in diagnosing pulmonary embolism, but MR venography is now used routinely in our hospital for the diagnosis of deep venous thrombosis. (orig.)

  5. Fish Intake and Venous Thromboembolism: A Systematic Literature Review.

    Science.gov (United States)

    Mattiuzzi, Camilla; Cervellin, Gianfranco; Franchini, Massimo; Lippi, Giuseppe

    2016-05-01

    Diet plays an important role in modulating the risk of arterial and venous thrombosis. Several lines of evidence attest that consumption of fish and its compounds, especially omega-3 fatty acids, may be effective to decrease the cardiovascular risk. Since the pathogenesis of arterial and venous thrombosis share some common aspects, we performed a systematic review of published clinical studies that investigated the association between fish intake and venous thrombosis. An electronic search was carried out in Medline, Scopus, and ISI Web of Science using the key words "fish" OR "seafood" AND "venous thromboembolism" OR "deep vein thrombosis" OR "pulmonary embolism", with no language or date restriction. Overall, 6 studies (5 prospective and 1 case-control) were finally identified. In only 1 small case-control study, a larger intake of total fish was found to be negatively associated with the risk of venous thromboembolism. No association was found in 4 large prospective studies, whereas a positive association was observed in the remaining. No substantial difference was also noticed between intake of fatty or lean fish. Taken together, the current epidemiological evidence does not support the existence of a significant effect of total fish consumption on the risk of venous thromboembolism. © The Author(s) 2015.

  6. Early thrombus removal strategies for acute deep venous thrombosis: clinical practice guidelines of the Society for Vascular Surgery and the American Venous Forum.

    Science.gov (United States)

    Meissner, Mark H; Gloviczki, Peter; Comerota, Anthony J; Dalsing, Michael C; Eklof, Bo G; Gillespie, David L; Lohr, Joann M; McLafferty, Robert B; Murad, M Hassan; Padberg, Frank; Pappas, Peter; Raffetto, Joseph D; Wakefield, Thomas W

    2012-05-01

    The anticoagulant treatment of acute deep venous thrombosis (DVT) has been historically directed toward the prevention of recurrent venous thromboembolism. However, such treatment imperfectly protects against late manifestations of the postthrombotic syndrome. By restoring venous patency and preserving valvular function, early thrombus removal strategies can potentially decrease postthrombotic morbidity. A committee of experts in venous disease was charged by the Society for Vascular Surgery and the American Venous Forum to develop evidence-based practice guidelines for early thrombus removal strategies, including catheter-directed pharmacologic thrombolysis, pharmacomechanical thrombolysis, and surgical thrombectomy. Evidence-based recommendations are based on a systematic review and meta-analysis of the relevant literature, supplemented when necessary by less rigorous data. Recommendations are made according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, incorporating the strength of the recommendation (strong: 1; weak: 2) and an evaluation of the level of the evidence (A to C). On the basis of the best evidence currently available, we recommend against routine use of the term "proximal venous thrombosis" in favor of more precise characterization of thrombi as involving the iliofemoral or femoropopliteal venous segments (Grade 1A). We further suggest the use of early thrombus removal strategies in ambulatory patients with good functional capacity and a first episode of iliofemoral DVT of venous outflow obstruction (Grade 1A). We suggest pharmacomechanical strategies over catheter-directed pharmacologic thrombolysis alone if resources are available and that surgical thrombectomy be considered if thrombolytic therapy is contraindicated (Grade 2C). Most data regarding early thrombus removal strategies are of low quality but do suggest patient-important benefits with respect to reducing postthrombotic morbidity. We

  7. Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.

    Science.gov (United States)

    Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya

    2015-01-01

    This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.

  8. Increased venous thrombosis incidence in pregnancies after in vitro fertilization

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Kesmodel, U S; Juul, S

    2014-01-01

    STUDY QUESTION Is venous thrombosis risk increased in pregnancies after in vitro fertilization? SUMMARY ANSWER The venous thrombosis incidence was significantly increased in pregnancies after in vitro fertilization; especially in the first trimester and in the first 6 weeks post-partum. WHAT...... IS KNOWN ALREADY In vitro fertilization without pregnancy is not associated with increased venous thrombosis incidence. STUDY DESIGN, SIZE, DURATION This national register-based cohort study covered the period from 1995 to 2005. PARTICIPANTS/MATERIALS, SETTING, METHODS All Danish pregnancies conceived...... by in vitro fertilization (n = 18 787) were included. Venous thrombosis incidence rates in pregnancies after in vitro fertilization were compared with venous thrombosis incidence rates in reference pregnancies, by calculating incidence rate ratios. MAIN RESULTS AND THE ROLE OF CHANCE In total, 48 cases were...

  9. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    Science.gov (United States)

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  10. The Current Role of Venous Sampling in the Localization of Endocrine Disease

    International Nuclear Information System (INIS)

    Lau, Jeshen H. G.; Drake, William; Matson, Matthew

    2007-01-01

    Endocrine venous sampling plays a specific role in the diagnosis of endocrine disorders. In this article, we cover inferior petrosal sinus sampling, selective parathyroid venous sampling, hepatic venous sampling with arterial stimulation, adrenal venous sampling, and ovarian venous sampling. We review their indications and the scientific evidence justifying these indications in the diagnosis and management of Cushing's syndrome, hyperparathyroidism, pancreatic endocrine tumors, Conn's syndrome, primary hyperaldosteronism, pheochromocytomas, and androgen-secreting ovarian tumors. For each sampling technique, we compare its diagnostic accuracy with that of other imaging techniques and, where possible, look at how it impacts patient management. Finally, we incorporate venous sampling into diagnostic algorithms used at our institution

  11. Venous thrombotic events in hospitalized children and adolescents with inflammatory bowel disease.

    Science.gov (United States)

    Nylund, Cade M; Goudie, Anthony; Garza, Jose M; Crouch, Gary; Denson, Lee A

    2013-05-01

    Adults with inflammatory bowel disease (IBD) have an increased risk of venous thrombotic events (TEs). We sought to evaluate the risk for TE in children and adolescents with IBD using a large population database. The triennial Healthcare Cost and Utilization Project Kids' Inpatient Database was used in a retrospective cohort study of hospitalized children in the United States across 1997, 2000, 2003, 2006, and 2009. Billing codes were used to identify discharges with Crohn disease, ulcerative colitis, pulmonary embolism, deep vein thrombosis, thrombophlebitis, thrombosis of intracranial venous sinus, Budd-Chiari syndrome, and portal vein thrombosis. A logistic regression model was fitted to quantify the increased risk of TE in children with IBD, while adjusting for other risk factors of thrombosis. The total weighted number of pediatric discharges was 7,448,292, and 68,394 (0.92%) were identified with IBD. The incidence of any TE in a hospitalized child or adolescent with IBD was 117.9/10,000 with a relative risk (95% confidence interval) of 2.36 (2.15-2.58). The adjusted odds ratio for any TE in a patient with IBD without surgery was 1.22 (1.08-1.36). Risk factors for TE among patients with IBD include older age, central venous catheter, parenteral nutrition, and an identified hypercoagulable condition. There is an increasing trend of TE in both the IBD and non-IBD patients. Hospitalized children and adolescents with IBD are at increased risk for TE. Conservative methods of TE prevention including hydration, mobilization, or pneumatic devices should be considered in hospitalized patients with IBD.

  12. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    Science.gov (United States)

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical

  13. Deep venous thrombosis and postthrombotic syndrome: invasive management.

    Science.gov (United States)

    Comerota, A J

    2015-03-01

    Invasive management of postthrombotic syndrome encompasses the two ends of the deep vein thrombosis spectrum, patients with acute iliofemoral deep vein thrombosis and those with chronic postthrombotic iliofemoral venous obstruction. Of all patients with acute deep vein thrombosis, those with involvement of the iliofemoral segments have the most severe chronic postthrombotic morbidity. Catheter-based techniques now permit percutaneous treatment to eliminate thrombus, restore patency, potentially maintain valvular function, and improve quality of life. Randomized trial data support an initial treatment strategy of thrombus removal. Failure to eliminate acute thrombus from the iliofemoral system leads to chronic postthrombotic obstruction of venous outflow. Debilitating chronic postthrombotic symptoms of the long-standing obstruction of venous outflow can be reduced by restoring unobstructed venous drainage from the profunda femoris vein to the vena cava. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Impact of quality management monitoring and intervention on central venous catheter dysfunction in the outpatient chemotherapy infusion setting.

    Science.gov (United States)

    Bansal, Anu; Binkert, Christoph A; Robinson, Malcolm K; Shulman, Lawrence N; Pellerin, Linda; Davison, Brian

    2008-08-01

    To assess the utility of maintaining and analyzing a quality-management database while investigating a subjectively perceived increase in the incidence of tunneled catheter and port dysfunction in a cohort of oncology outpatients. All 152 patients undergoing lytic therapy (2-4 mg alteplase) of a malfunctioning indwelling central venous catheter (CVC) from January through June 2004 at a single cancer center in the United States were included in a quality-management database. Patients were categorized by time to device failure and the initial method of catheter placement (surgery vs interventional radiology). Data were analyzed after 3 months, and areas of possible improvement were identified and acted upon. Three months of follow-up data were then collected and similarly analyzed. In a 6-month period, 152 patients treated for catheter malfunction received a total of 276 doses of lytic therapy. A 3-month interim analysis revealed a disproportionately high rate (34%) of early catheter malfunction (ECM; <30 days from placement). Postplacement radiographs demonstrated suboptimal catheter positioning in 67% of these patients, all of whom had surgical catheter placement. There was a 50% absolute decrease in the number of patients presenting with catheter malfunction in the period from April through June (P < .001). Evaluation of postplacement radiographs in these patients demonstrated a 50% decrease in the incidence of suboptimal positioning (P < .05). Suboptimal positioning was likely responsible for some, but not all, cases of ECM. Maintenance of a quality-management database is a relatively simple intervention that can have a clear and important impact on the quality and cost of patient care.

  15. Anticoagulation period in idiopathic venous thromboembolism

    International Nuclear Information System (INIS)

    Farraj, Rami S.

    2004-01-01

    The period of anticoagulation of a first episode of idiopathic venous thromboembolism has been 6 months. It is unclear if such patients would benefit from longer treatment, as there appears to be an increased risk of recurrence after anticoagulation is stopped. In a randomized prospective study of 64 patients admitted to King Hussein Medical city, Amman, Jordan, who developed a first episode of venous thromboembolism, 32 patients were given warfarin for 24-months, while 32 patients stopped anticoagulation after completion of 6-months of therapy. Our goal was to determine the effects of extended anticoagulation on rates of recurrence of symptomatic venous thromboembolism and bleeding. The patients were followed for 12-months after stopping anticoagulation. After 24-months, 7 of the 32 patients (21%) who had standard anticoagulation for 6-months had a recurrent episode of thromboembolism compared to one of the 32 patients who received anticoagulation for 24 months (3%). Extended warfarin therapy for 24-months has resulted in an absolute risk reduction of 0.1% (p<0.05). This translates into 8 patients having to be treated for 24-months to avoid one recurrence without increasing the risk of major bleeding. Two patients in each group (6%) had major nonfatal bleeding, all 4 bleeding episodes occurring within the first 3-months of anticoagulation. After 36-months of follow up, the recurrence rate of extended warfarin therapy was only 3 patients (9%), which is a 43% relative reduction in recurrence of thromboembolism compared to standard therapy for 6-months. Patients with first episodes of idiopathic venous thromboembolism have an increased risk of recurrent venous thromboembolism and should be treated with oral anticoagulants for longer than 6-months, probably 24-months. (author)

  16. Improving patient safety during insertion of peripheral venous catheters: an observational intervention study

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2013-11-01

    Full Text Available [english] Background: Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps.Methods: The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology. A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback, followed by a second observation period. During the last observation week, participants evaluated the intervention.Results: In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test. Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after. Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68

  17. A phase III, open-label, single-arm study of tenecteplase for restoration of function in dysfunctional central venous catheters.

    Science.gov (United States)

    Tebbi, Cameron; Costanzi, John; Shulman, Robert; Dreisbach, Luke; Jacobs, Brian R; Blaney, Martha; Ashby, Mark; Gillespie, Barbara S; Begelman, Susan M

    2011-08-01

    To evaluate, in a phase III, single-arm study, the safety and efficacy of the thrombolytic agent tenecteplase in restoring function to dysfunctional central venous catheters (CVCs). Pediatric and adult patients with dysfunctional CVCs were eligible to receive as much as 2 mL (2 mg) of intraluminal tenecteplase, which was left to dwell in the CVC lumen for a maximum of 120 minutes. If CVC function was not restored at 120 minutes, a second dose was instilled for an additional 120 minutes. Tenecteplase was administered to 246 patients. Mean patient age was 44 years (range, 0-92 y); 72 patients (29%) were younger than 17 years of age. Chemotherapy was the most common reason for catheter insertion. Restoration of CVC function was achieved in 177 patients (72%) within 120 minutes after the first dose. After instillation of a maximum of two doses of tenecteplase, CVC function was restored in 200 patients (81%), with similar frequencies in pediatric (83%) and adult (80%) patients. Adverse events (AEs) were reported in 31 patients (13%); fever (2%), neutropenia (1%), and nausea (0.8%) were most common. One serious AE, an allergic hypersensitivity reaction, was judged to be related to tenecteplase and/or a chemotherapeutic agent that the patient was receiving concurrently. Consecutive administration of one or two doses of tenecteplase into CVCs showed efficacy in the restoration of catheter function in patients with dysfunctional CVCs. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  18. Bilateral chylothorax in a patient with chronic central vein thrombosis and chronic thromboembolic pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Avdhesh Bansal

    2015-01-01

    Full Text Available The chylothorax is not a common presentation, and bilateral chylothorax in patients with chronically high central venous pressure secondary to venous thrombosis is a rare in incidence. We reported a case of bilateral chylothorax in a patient of chronic deep vein thrombosis (DVT in central veins with chronic thromboembolic pulmonary hypertension who presented with 2 weeks history of increased breathlessness, bilateral chest discomfort and weakness. Work-up with chest X-ray and ultrasonography-chest showed gross left sided and mild right sided pleural effusion, thoracocentesis was consistent with chylothorax. Contrast enhanced computed tomography-chest showed multiple collateral formation of left side subclavian vein, venous Doppler showed old DVT in right and left subclavian veins and two-dimensional echocardiogram showed finding of severe pulmonary hypertension. After 24 h of fasting and conservative management, pleural drain became clear and decreased in the amount. Patient′s video assisted thoracoscopic surgery was done, and thoracic duct was ligated and cut down at diaphragmatic level and bilateral talc pleurodesis done. Patient improved clinically and radiologically.

  19. Traumatic dural venous sinus thrombosis: A Mini Review

    Directory of Open Access Journals (Sweden)

    Moscote-Salazar Luis Rafael

    2016-09-01

    Full Text Available The dural venous sinus thrombosis is a benign disease, representing about 1% of cerebral vascular events. In some cases the development of the disease increased intracranial pressure or symptomatic epilepsy. The development towards a dural venous sinus thrombosis is rare, but is a condition to be considered before the development of ischemic vascular events and a history of recent head trauma. Intracranial hematomas or skull fractures can lead to the establishment of obstructive pathology of the dural venous sinuses. The knowledge of this entity is necessary for the critical care staff and neurosurgery staff.

  20. Developmental venous anomalies with capillary stain: a subgroup of symptomatic DVAs?

    NARCIS (Netherlands)

    Roccatagliata, Luca; van den Berg, René; Soderman, Michael; Boulin, Anne; Condette-Auliac, Stéphanie; Rodesch, Georges

    2012-01-01

    Intracranial developmental venous anomalies (DVAs) are considered benign vascular dispositions; they are asymptomatic in the vast majority of cases. They represent extreme variations of the venous drainage and may rarely be responsible for focal venous ischemia leading to neurological dysfunction.

  1. Arterial versus venous lactate: a measure of sepsis in children.

    Science.gov (United States)

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous

  2. Evaluation of treatment with carboxymethylcellulose on chronic venous ulcers*

    Science.gov (United States)

    Januário, Virginia; de Ávila, Dione Augusto; Penetra, Maria Alice; Sampaio, Ana Luisa Bittencourt; Noronha Neta, Maria Isabel; Cassia, Flavia de Freire; Carneiro, Sueli

    2016-01-01

    BACKGROUND: Among the chronic leg ulcers, venous ulcers are the most common and constitute a major burden to public health. Despite all technology available, some patients do not respond to established treatments. In our study, carboxymethylcellulose was tested in the treatment of refractory chronic venous ulcers. OBJECTIVE: To evaluate the efficacy of carboxymethylcellulose 20% on the healing of chronic venous ulcers refractory to conventional treatments. METHODS: This is an analytical, pre-experimental study. Thirty patients were included with refractory venous ulcers, and applied dressings with carboxymethylcellulose 20% for 20 weeks. The analysis was based on measurement of the area of ulcers, performed at the first visit and after the end of the treatment. RESULTS: There was a reduction of 3.9 cm2 of lesion area (p=0.0001), corresponding to 38.8% (p=0.0001). There was no interruption of treatment and no increase in lesion area in any patient. CONCLUSIONS: Carboxymethylcellulose 20% represents a low cost and effective therapeutic alternative for the treatment of refractory chronic venous ulcers. However, controlled studies are necessary to prove its efficacy. PMID:26982773

  3. Counteracting venous stasis during acute lower leg immobilization.

    NARCIS (Netherlands)

    Poelkens, F.; Thijssen, D.H.J.; Kersten, B.T.P.; Scheurwater, H.; Laarhoven, E.W. van; Hopman, M.T.E.

    2006-01-01

    AIM: During lower limb immobilization, patients are at risk to develop deep venous thrombosis. Recently, a water-pad was developed that should counteract venous stasis. The water-pad, located under the plaster, mobilizes water from the foot to the calf during weight bearing and, thereby, imitates

  4. Radiological evaluation of the chronic venous stasis syndrome

    International Nuclear Information System (INIS)

    Train, J.S.; Schanzer, H.; Peirce, E.C. II; Dan, S.J.; Mitty, H.A.

    1987-01-01

    Chronic venous stasis is an extremely complex clinical syndrome of pain and changes in the skin that can involve the superficial, deep, and perforating veins. This syndrome is commonly referred to as the postphlebitic syndrome, implying that thrombophlebitis is its sole etiology. To test this hypothesis, the authors performed ascending venography on 51 limbs of patients with the chromic venous stasis syndrome and demonstrated that 32 had no radiological evidence of recent or old thrombophlebitis. Instead, they had normal-appearing veins, suggesting primary incompetence of the deep and/or perforating venous valves rather than thrombophlebitis as the etiology. Since various operations have recently been proposed to correct or bypass malfunctioning valves, precise demonstration of pathological change is required to choose the appropriate procedure and to evaluate results. Descending venograms were combined with the ascending studies in 42 limbs for this purpose. In addition to outlining the abnormalities responsible for chronic venous stasis syndrome in individual cases, interesting conclusions regarding the syndrome itself were reached

  5. Evaluation of risk factors for thrombophilia in patients with cerebral venous thrombosis

    Directory of Open Access Journals (Sweden)

    Osman Yokuş

    2010-09-01

    Full Text Available Objective: The increased risk for thrombosis is known as hypercoagulability or thrombophilia. In our study, we aimed to determine the frequency of the identified defects for thrombophilia in patients with central venous thrombosis aged under 50 years and to compare results with the findings in the current literature. Materials and Methods: Forty-three patients (16-50 years old were retrospectively evaluated. Thrombophilia investigation included determinations of protein C, protein S, antithrombin, and activated protein C resistance, factor V Leiden (FVL, prothrombin 20210A (PT 20210 and methylene tetrahydrofolate reductase (MTHFR C677T mutations, antiphospholipid antibodies (APA, factor VIII levels, and homocysteine levels. Results: We detected a single thrombophilic defect in 67.4%, two defects in 27.9% and three defects in 4.7% of our patients. The most common thrombophilic defect was mutation in the MTHFR gene (41.8%, and this was followed by the FVL mutation (34.9%.Conclusion: Since the prevalence of individual thrombophilic defects varies in each population, ethnic group and geographical location, screening for thrombophilic defects in patients presenting with cerebral venous thrombosis should primarily investigate the most frequent thrombophilia risk factors.

  6. An unusual cause of hydrocephalus: aqueductal developmental venous anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Yagmurlu, Banu; Fitoz, Suat; Atasoy, Cetin; Erden, ilhan [Ankara University School of Medicine, Department of Radiology, Ankara (Turkey); Deda, Gulhis; Unal, Ozlem [Ankara University School of Medicine, Division of Pediatric Neurology, Ankara (Turkey)

    2005-06-01

    Vascular malformations are infrequent causes of aqueductal stenoses, developmental venous anomaly (DVA) being the rarest among them. DVAs, also known as venous angiomas, are congenital in origin and characterized by dilatation of vessels in the superficial and deep venous system. Although they are usually clinically silent, they can be complicated by hemorrhage, seizures and neurologic deficits. Herein, we report MR imaging findings of a 7-year-old girl whose hydrocephalus was due to an abnormal vein coursing through the aqueduct. (orig.)

  7. How to objectively assess jugular primary venous obstruction

    Directory of Open Access Journals (Sweden)

    Paolo Zamboni

    2014-12-01

    Full Text Available Last January The Lancet published the article by Traboulsee et al. Prevalence of extracranial venous narrowing on catheter venography in people with multiple sclerosis, their sibilings, and unrelated healthy controls: a blinded, case control study. These Authors confirmed the presence of chronic cerebrospinal venous insufficiency with a high prevalence of about 70% in the Canadian population, but without significant differences between patients and healthy controls, yet. However, they used a criterion never published to assess stenosis, in alternative to the classic measurement of the diameter in the segment immediately preceding the narrowest point. Traboulsee et al. measure the stenosis along the entire length of the internal jugular vein, by comparing the maximum diameter with the narrowest point. It has been demonstrated, from normal anatomy findings, how the jugular bulb diameter normally exceeds 50% of the minimum diameter of the internal jugular vein, clearly showing the reason why Traboulsee et al. did not find significant differences between people with multiple sclerosis, their sibilings, and unrelated healthy controls. Furthermore, as the outcome measure of Traboulsee et al., wall stenosis is a neglected part of primary venous obstruction, because in the majority of cases obstruction is the consequence of intraluminal obstacles, as a considerable part of truncular venous malformations, and/or compression; rarely of external hypoplasia. Finally, several recently published methods can be adopted for objective assessment of restricted jugular flow in course of chronic cerebrospinal venous insufficiency, by the means of non invasive magnetic resonance imaging, ultrasound and plethysmography. This may help us in improving the assessment of cerebral venous return in the near future.

  8. Venous Thromboembolism in Podiatric Foot and Ankle Surgery.

    Science.gov (United States)

    Matthews, Jemma H; Terrill, Alexander J; Barwick, Alex L; Butterworth, Paul A

    2018-01-01

    The extent to which podiatric surgeons follow venous thromboembolism guidelines is unknown. The aim of this study therefore, was 2-fold: (a) to determine the rate of venous thromboembolism following podiatric surgery and (b) to investigate the factors that influence the use of thromboprophylaxis. Data from 4238 patients who underwent foot and ankle surgery over 2 years were analyzed. Venous thromboembolism within the first 30 days following surgery was recorded using the Australasian College of Podiatric Surgeons surgical audit tool. Logistic regression analyses were undertaken to determine the factors that influenced thromboprophylaxis. Of the 4238 patient records, 3677 records (87%) provided complete data (age range 2-94 years; mean ± SD, 49.1 ± 19.7 years; 2693 females). A total of 7 venous thromboembolic events (0.2% rate) were reported. Operative duration and age (OR 12.63, 95% CI 9.47 to 16.84, P < 0.01), postoperative immobilization (OR 6.94, 95% CI 3.95 to 12.20, P < 0.01), and a prior history of VTE (OR 3.41, 95% CI 1.01 to 11.04, P = 0.04) were the strongest predictors of thromboprophylaxis. Podiatric foot and ankle surgery is associated with a low rate of venous thromboembolism. This may be due in part to the thromboprophylaxis regime implemented by podiatric surgeons, which closely aligns with current evidence-based guidelines. Level II: Prospective cohort study.

  9. Lactate, endothelin, and central venous oxygen saturation as predictors of mortality in patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Poonam Malhotra Kapoor

    2016-01-01

    Full Text Available Background: Lactate and central venous oxygen saturation (ScVO2 are well known biomarkers for adequacy of tissue oxygenation. Endothelin, an inflammatory marker has been associated with patient′s nutritional status and degree of cyanosis. The aim of this study was to explore the hypothesis that lactate, ScVO2 and endothelin before induction may be predictive of mortality in pediatric cardiac surgery. Methods: We conducted a prospective observational study of 150 pediatric (6 months to 12 years patients who were posted for intracardiac repair for tetralogy of fallot and measured lactate, ScVO2 and endothelin before induction (T1, 20 minutes after protamine administration (T2 and 24 hours after admission to ICU (T3. Results: Preinduction lactate and endothelin levels were found to predict mortality in patients of tetralogy of fallot with an odds ratio of 6.020 (95% CI 2.111-17.168 and 1.292(95% CI 1.091-1.531 respectively. In the ROC curve analysis for lactate at T1, the AUC was 0.713 (95% CI 0.526-0.899 P = 0.019. At the cutoff value of 1.750mmol/lt, the sensitivity and specificity for the prediction of mortality was 63.6% and 65.5%, respectively. For endothelin at T1, the AUC was 0.699 (95% CI 0.516-0.883, P = 0.028 and the cutoff value was ≤2.50 (sensitivity, 63.6%; specificity, 58.3 %. ScVO2 (odds ratio 0.85 at all three time intervals, suggested that improving ScVO2 can lead to 15% reduction in mortality. Conclusions: Lactate, ScVO2 and endothelin all showed association with mortality with lactate having the maximum prediction. Lactate was found to be an independent, reliable and cost-effective measure of prediction of mortality in patients with tetralogy of fallot.

  10. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  11. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock

    OpenAIRE

    Mo?ina, Hugo; Podbregar, Matej

    2010-01-01

    Introduction Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the rela...

  12. Visualization of coronary venous anatomy by cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Crean Andrew

    2009-08-01

    Full Text Available Abstract Background Coronary venous imaging with whole-heart cardiovascular magnetic resonance (CMR angiography has recently been described using developmental pulse sequences and intravascular contrast agents. However, the practical utility of coronary venous imaging will be for patients with heart failure in whom cardiac resynchronisation therapy (CRT is being considered. As such complementary information on ventricular function and myocardial viability will be required. The aim of this study was to determine if the coronary venous anatomy could be depicted as part of a comprehensive CMR protocol and using a standard extracellular contrast agent. Methods and Results Thirty-one 3D whole heart CMR studies, performed after intravenous administration of 0.05 mmol/kg gadolinium DTPA, were reviewed. The cardiac venous system was visualized in all patients. The lateral vein of the left ventricle was present in 74%, the anterior interventricular vein in 65%, and the posterior interventricular vein in 74% of patients. The mean maximum distance of demonstrable cardiac vein on the 3D images was 81.5 mm and was dependent on the quality of the 3D data set. Five patients showed evidence of myocardial infarction on late gadolinium enhancement (LGE images. Conclusion Coronary venous anatomy can be reliably demonstrated using a comprehensive CMR protocol and a standard extracellular contrast agent. The combination of coronary venous imaging, assessment of ventricular function and LGE may be useful in the management of patients with LV dysfunction being considered for CRT.

  13. Admission Hyperglycemia and Clinical Outcome in Cerebral Venous Thrombosis

    NARCIS (Netherlands)

    Zuurbier, Susanna M.; Hiltunen, Sini; Tatlisumak, Turgut; Peters, Guusje M.; Silvis, Suzanne M.; Haapaniemi, Elena; Kruyt, Nyika D.; Putaala, Jukka; Coutinho, Jonathan M.

    2016-01-01

    Background and Purpose-Admission hyperglycemia is associated with poor clinical outcome in ischemic and hemorrhagic stroke. Admission hyperglycemia has not been investigated in patients with cerebral venous thrombosis. Methods-Consecutive adult patients with cerebral venous thrombosis were included

  14. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  15. Idiopathic versus secondary venous thromboembolism. Findings of the RIETE registry.

    Science.gov (United States)

    Pedrajas, J M; Garmendia, C; Portillo, J; Gabriel, F; Mainez, C; Yera, C; Monreal, M

    2014-10-01

    The Computerized Registry of Patients with Venous Thromboembolism (RIETE) is a prospective registry that consecutively includes patients diagnosed with venous thromboembolism. We compared the clinical presentation and response to anticoagulant treatment in patients with idiopathic venous thromboembolism (IVT) versus secondary venous thromboembolism (SVT, associated with a risk factor). We analyzed the differences in clinical characteristics, comorbidity, treatment and events during the first 3months after the diagnosis of venous thromboembolism in patients with IVT or SVT and according to their initial clinical presentation. A total of 39,921 patients with IVT (n=18,029; 45.1%) or SVT (n=21,892; 54.9%) were enrolled. The patients with IVT had a greater history of venous thromboembolism than those diagnosed with SVT (p<.001). The initial treatment was similar for the 2 groups, but more inferior vena cava filters were placed in the SVT group (p<.001). In the long term, low-molecular-weight heparin was used more often in the SVT group than in the IVT group. At 90days, bleeding, death and the recurrence of venous thromboembolism were significantly more frequent in the SVT group. The multivariate analysis confirmed that IVT was associated with fewer major (OR, 0.60; 95%CI, 0.50-0.61; p<.001) and fatal (OR, 0.41; 95%CI, 0.29-0.62; p<.001) bleedings, fewer relapses (OR, 0.58; 95%CI, 0.39-0.78; p<.001) and fewer fatal pulmonary embolisms (OR, 0.29; 95%CI, 0.12-0.52; p<.001). These differences were maintained in patients whose venous thromboembolism started with a pulmonary embolism or with deep vein thrombosis. IVT has a better prognosis than SVT at 90days of the diagnosis. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  16. Complication of Hemodialysis Access: A Case Report of Venous Hypertension

    Directory of Open Access Journals (Sweden)

    Sadegh Asadi

    2018-03-01

    Full Text Available Vascular access for dialysis is essential for these patients with end-stage renal disease, improvements in hemodialysis managment have lead to extended life expectancy. The creation and maintenance of hemoaccess occupies a significant portion of most vascular and general surgery practices.Venous hypertension due to arteriovenous fistula is usually secondary to venous outlet obstruction. Side to side proximal artery arteriovenous fistula serves as a certain cause of hemodialysis, but it is rarely reported as a peripheral venous hypertension cause. We are reporting a case with developed venous hypertension having dermal injuries in the arm. The patient underwent successful side-to-side radio cephalic fistula creation in the snuffbox a year ago.

  17. Partial anomalous pulmonary venous return in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Sung, Won-kyung; Au, Virginia; Rose, Anand

    2012-01-01

    Anomalous pulmonary venous return is an uncommon congenital malformation, and may be partial or total. Partial anomalous pulmonary venous return (PAPVR) is more common than total anomalous pulmonary venous return, and is often associated with other congenital cardiac anomalies. Whilst many patients with PAPVR remain asymptomatic, some may present in later age with symptoms related to left-to-right shunt, right heart failure and pulmonary hypertension. We report two cases of PAPVR detected on Computed Tomography Pulmonary Angiogram (CTPA) for the work up of pulmonary hypertension. The cases demonstrate that, although uncommon, partial anomalous pulmonary venous return can be a contributing factor to pulmonary hypertension and pulmonary veins should be carefully examined when reading a CTPA study.

  18. Investigation of cerebral venous outflow in microgravity.

    Science.gov (United States)

    Taibi, A; Gadda, G; Gambaccini, M; Menegatti, E; Sisini, F; Zamboni, P

    2017-10-31

    The gravitational gradient is the major component to face when considering the physiology of venous return, and there is a growing interest in understanding the mechanisms ensuring the heart filling, in the absence of gravity, for astronauts who perform long-term space missions. The purpose of the Drain Brain project was to monitor the cerebral venous outflow of a crew member during an experiment on the International Space Station (ISS), so as to study the compensatory mechanisms that facilitate this essential physiological action in subjects living in a microgravity environment. Such venous function has been characterized by means of a novel application of strain-gauge plethysmography which uses a capacitive sensor. In this contribution, preliminary results of our investigation have been presented. In particular, comparison of plethysmography data confirmed that long duration spaceflights lead to a redistribution of venous blood volume, and showed interesting differences in the amplitude of cardiac oscillations measured at the level of the neck veins. The success of the experiment has also demonstrated that thanks to its easy portability, non-invasiveness, and non-operator dependence, the proposed device can be considered as a novel tool for use aboard the ISS. Further trials are now under way to complete the investigation on the drainage function of the neck veins in microgravity.

  19. Central venous catheter infections in home parenteral nutrition patients: Outcomes from Sustain: American Society for Parenteral and Enteral Nutrition's National Patient Registry for Nutrition Care.

    Science.gov (United States)

    Ross, Vicki M; Guenter, Peggi; Corrigan, Mandy L; Kovacevich, Debra; Winkler, Marion F; Resnick, Helaine E; Norris, Tina L; Robinson, Lawrence; Steiger, Ezra

    2016-12-01

    Home parenteral nutrition (HPN) is a high-cost, complex nutrition support therapy that requires the use of central venous catheters. Central line-associated bloodstream infections (CLABSIs) are among the most serious risks of this therapy. Sustain: American Society for Parenteral and Enteral Nutrition's National Patient Registry for Nutrition Care (Sustain registry) provides the most current and comprehensive data for studying CLABSI among a national cohort of HPN patients in the United States. This is the first Sustain registry report detailing longitudinal data on CLABSI among HPN patients. To describe CLABSI rates for HPN patients followed in the Sustain registry from 2011-2014. Descriptive, χ 2 , and t tests were used to analyze data from the Sustain registry. Of the 1,046 HPN patients from 29 sites across the United States, 112 (10.7%) experienced 194 CLABSI events during 223,493 days of HPN exposure, for an overall CLABSI rate of 0.87 episodes/1,000 parenteral nutrition-days. Although the majority of patients were female (59%), adult (87%), white (75%), and with private insurance or Medicare (69%), CLABSI episodes per 1,000 parenteral nutrition-days were higher for men (0.69 vs 0.38), children (1.17 vs 0.35), blacks (0.91 vs 0.41), and Medicaid recipients (1.0 vs 0.38 or 0.39). Patients with implanted ports or double-lumen catheters also had more CLABSIs than those with peripherally inserted or central catheters or single-lumen catheters. Staphylococci were the most commonly reported pathogens. These data support findings of smaller studies about CLABSI risk for children and by catheter type and identify new potential risk factors, including gender, race, and insurance type. Additional studies are needed to determine effective interventions that will reduce HPN-associated CLABSI. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.

    Science.gov (United States)

    Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R

    2018-03-25

    Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (pBMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.

  1. Use of simulation-based education to improve outcomes of central venous catheterization: a systematic review and meta-analysis.

    Science.gov (United States)

    Ma, Irene W Y; Brindle, Mary E; Ronksley, Paul E; Lorenzetti, Diane L; Sauve, Reg S; Ghali, William A

    2011-09-01

    Central venous catheterization (CVC) is increasingly taught by simulation. The authors reviewed the literature on the effects of simulation training in CVC on learner and clinical outcomes. The authors searched computerized databases (1950 to May 2010), reference lists, and considered studies with a control group (without simulation education intervention). Two independent assessors reviewed the retrieved citations. Independent data abstraction was performed on study design, study quality score, learner characteristics, sample size, components of interventional curriculum, outcomes assessed, and method of assessment. Learner outcomes included performance measures on simulators, knowledge, and confidence. Patient outcomes included number of needle passes, arterial puncture, pneumothorax, and catheter-related infections. Twenty studies were identified. Simulation-based education was associated with significant improvements in learner outcomes: performance on simulators (standardized mean difference [SMD] 0.60 [95% CI 0.45 to 0.76]), knowledge (SMD 0.60 [95% CI 0.35 to 0.84]), and confidence (SMD 0.41 [95% CI 0.30 to 0.53] for studies with single-group pretest and posttest design; SMD 0.52 (95% CI 0.23 to 0.81) for studies with nonrandomized, two-group design). Furthermore, simulation-based education was associated with improved patient outcomes, including fewer needle passes (SMD -0.58 [95% CI -0.95 to -0.20]), and pneumothorax (relative risk 0.62 [95% CI 0.40 to 0.97]), for studies with nonrandomized, two-group design. However, simulation-based training was not associated with a significant reduction in risk of either arterial puncture or catheter-related infections. Despite some limitations in the literature reviewed, evidence suggests that simulation-based education for CVC provides benefits in learner and select clinical outcomes.

  2. Carbon dioxide as a venous contrast agent: Applications in interventional radiology=20

    International Nuclear Information System (INIS)

    Hahn, Seong Tae; Lee, Jae Mun; Kim, Choon Yul; Shinn, Kyung Sub; Pfammatter, Thomas; Cho, Kyung Jae

    1997-01-01

    To evaluate the safety and usefulness of carbon dioxide(CO 2 ) as a venous contrast agent for upper-arm placement of peripherally inserted central venous catheter (PICC), vena caval filter placement, and for visualization of the portal vein in transjugular intrahepatic portosystemic shunt(TIPS). About 20-30ml of CO 2 was used as an alternative to iodinated contrast material for digital subtraction angiography (DSA) and fluoroscopy to guide upper-arm placement of PICC in 46 patients, for inferior venacavogram before filter placement in five, and for visualization of the portal vein during TIPS in two. Vital signs, peripheral arterial oxygen saturation, and renal function were checked during and after delivery of CO 2 . All CO 2 DSA for PICC placement clearly delineated patency or stenosis of the central veins. In 41 of 46 patients (89 %), PICC placement with CO 2 guidance was successful. The mean number of venipunctures for PICC placement was 1.9, and the mean volume of CO 2 injected for venipuncture was 35ml. In five patients, Titanium Greenfield filters were successfully implanted into the inferior vena cava following CO 2 vena cavography. In two patients in whom hepatopetal portal flow was seen on indirect portography, the portal vein was visualized by CO 2 -wedged hepatic venography. Injection of CO 2 into the splenic vein following TIPS placement revealed shunt patency. Vital signs and oxygen saturation did not change, and there was no evidence of renal toxicity following CO 2 injection. CO 2 is a safe and useful alternative contrast agent for upper-arm placement of PICC, pre-filter placement cavography, and wedged hepatic venography and portography for TIPS

  3. Cortical venous disease severity in MELAS syndrome correlates with brain lesion development.

    Science.gov (United States)

    Whitehead, M T; Wien, M; Lee, B; Bass, N; Gropman, A

    2017-08-01

    MELAS syndrome is a mitochondrial disorder typified by recurrent stroke-like episodes, seizures, and progressive brain injury. Abnormal mitochondria have been found in arterial walls implicating a vasculogenic etiology. We have observed abnormal cortical vein T2/FLAIR signal in MELAS patients, potentially representing wall thickening and sluggish flow. We sought to examine the relationship of hyperintense veins and brain lesions in MELAS. Imaging databases at two children's hospitals were searched for brain MRIs from MELAS patients. Artifact, sedated exams, and lack of 2D-T2/FLAIR sequences were exclusion criteria. Each exam was assigned a venous score based on number of T2/FLAIR hyperintense veins: 1 = 20. Cumulative brain lesions and venous score in MELAS and aged-matched normal exams were compared by Mann-Whitney test. A total of 106 exams from 14 unique MELAS patients (mean 16 ± 3 years) and 30 exams from normal aged-matched patients (mean 15 ± 3 years) were evaluated. Median venous score between MELAS and control patients significantly differed (3 versus 1; p MELAS group, venous score correlated with presence (median = 3) or absence (median = 1) of cumulative brain lesions. In all 8 MELAS patients who developed lesions, venous hyperintensity was present prior to, during, and after lesion onset. Venous score did not correlate with brain lesion acuity. Abnormal venous signal correlates with cumulative brain lesion severity in MELAS syndrome. Cortical venous stenosis, congestion, and venous ischemia may be mechanisms of brain injury. Identification of cortical venous pathology may aid in diagnosis and could be predictive of lesion development.

  4. Direct Open Venous Drainage: An Alternative Choice for Flap Congestion Salvage.

    Science.gov (United States)

    Park, Su Han; Choi, Woo Young; Son, Kyung Min; Cheon, Ji Seon; Yang, Jeong Yeol

    2015-12-01

    In this report, we present a scalp defect reconstruction with lateral arm free flap. We highlight the difficulty in obtaining a recipient vein and the venous drainage managed through an open end of the donor vein. A 52-year-old woman presented with a pressure sore on the left scalp. A lateral arm free flap was transferred to cover this 8×6 cm defect. The arterial anastomosis was successful, but no recipient vein could be identified within the wound bed. Instead, we used a donor venous end for the direct open venous drainage. In order to keep this exposed venous end patent, we applied heparin-soaked gauze dressing to the wound. Also, the vein end was mechanically dilated and irrigated with heparin solution at two hour intervals. Along with fluid management and blood transfusion, this management was continued for the five days after the operation. The flap survived well without any complication. Through this case, we were able to demonstrate that venous congestion can be avoided by drainage of the venous blood through an open vessel without the use of leeches.

  5. Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study.

    Science.gov (United States)

    Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges

    2012-06-14

    We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.

  6. Second-Generation central venous catheter in the prevention of bloodstream infection: a systematic review.

    Science.gov (United States)

    Stocco, Janislei Gislei Dorociaki; Hoers, Hellen; Pott, Franciele Soares; Crozeta, Karla; Barbosa, Dulce Aparecida; Meier, Marineli Joaquim

    2016-08-08

    to evaluate the effectiveness and safety in the use of second-generation central venous catheters impregnated in clorhexidine and silver sulfadiazine when compared with other catheters, being them impregnated or not, in order to prevent the bloodstream infection prevention. systematic review with meta-analysis. Databases searched: MEDLINE, EMBASE, CINAHL, LILACS/SciELO, Cochrane CENTRAL; search in Congress Proceedings and records from Clinical Trials. 1.235 studies were identified, 97 were pre-selected and 4 were included. In catheter-related bloodstream infection, there was no statistical significance between second-generation impregnated catheter compared with the non-impregnated ones, absolute relative risk 1,5% confidence interval 95% (3%-1%), relative risk 0,68 (confidence interval 95%, 0,40-1,15) and number needed to treat 66. In the sensitivity analysis, there was less bloodstream infection in impregnated catheters (relative risk 0,50, confidence interval 95%, 0,26-0,96). Lower colonization, absolute relative risk 9,6% (confidence interval 95%, 10% to 4%), relative risk 0,51 (confidence interval 95% from 0,38-0,85) and number needed to treat 5. the use of second-generation catheters was effective in reducing the catheter colonization and infection when a sensitivity analysis is performed. Future clinical trials are suggested to evaluate sepsis rates, mortality and adverse effects. evaluar la efectividad y seguridad del uso de catéteres venosos centrales de segunda generación, impregnados en clorhexidina y sulfadiazina de plata, comparados con otros catéteres impregnados o no impregnados, para prevención de infección de la corriente sanguínea. revisión sistemática con metaanálisis. La búsqueda fue realizada en las bases: MEDLINE, EMBASE, CINAHL, LILACS/SciELO, Cochrane CENTRAL; fueron consultados anales de congresos y registros de ensayos clínicos. fueron identificados 1.235 estudios, 97 preseleccionados y cuatro incluidos. En la infección de la

  7. Central venous catheter-related infections in hematology and oncology: 2012 updated guidelines on diagnosis, management and prevention by the Infectious Diseases Working Party of the German Society of Hematology and Medical Oncology.

    Science.gov (United States)

    Hentrich, M; Schalk, E; Schmidt-Hieber, M; Chaberny, I; Mousset, S; Buchheidt, D; Ruhnke, M; Penack, O; Salwender, H; Wolf, H-H; Christopeit, M; Neumann, S; Maschmeyer, G; Karthaus, M

    2014-05-01

    Cancer patients are at increased risk for central venous catheter-related infections (CRIs). Thus, a comprehensive, practical and evidence-based guideline on CRI in patients with malignancies is warranted. A panel of experts by the Infectious Diseases Working Party (AGIHO) of the German Society of Hematology and Medical Oncology (DGHO) has developed a guideline on CRI in cancer patients. Literature searches of the PubMed, Medline and Cochrane databases were carried out and consensus discussions were held. Recommendations on diagnosis, management and prevention of CRI in cancer patients are made, and the strength of the recommendation and the level of evidence are presented. This guideline is an evidence-based approach to the diagnosis, management and prevention of CRI in cancer patients.

  8. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    International Nuclear Information System (INIS)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K.

    2005-01-01

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  9. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K. [Johns Hopkins Hospital, Baltimore, MD (United States). The Russell H. Morgan Department of Radiology and Radiological Science

    2005-03-15

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  10. Surgical site infection after central venous catheter-related infection in cardiac surgery. Analysis of a cohort of 7557 patients.

    Science.gov (United States)

    Le Guillou, V; Tavolacci, M-P; Baste, J-M; Hubscher, C; Bedoit, E; Bessou, J-P; Litzler, P-Y

    2011-11-01

    The aim of this study was to establish the relationship between the occurrence of a surgical site infection (SSI) and the presence of a central venous catheter-related infection (CVCRI). The Department of Thoracic and Cardiovascular Surgery, University Hospital, Rouen, has carried out a prospective epidemiological survey of all nosocomial infections (pneumonia, SSI and CVCRI) since 1997. The study group included all consecutive patients who underwent cardiac surgery over a 10-year period from 1997 to 2007. A nested case-control study was conducted to identify the risk factors for SSI after CVCRI. Cases were patients with SSI after CVCRI and controls were randomized from patients who presented with CVCRI not followed by SSI. In total, 7557 patients were included and 133 SSIs (1.7%) were identified. The rate of superficial SSI was 0.7% [95% confidence interval (CI): 0.5-0.9] and of mediastinitis was 1.0% (95% CI: 0.8-1.2). Among the 133 cases of SSI, 12 (9.0%; 95% CI: 5.0-14.8) occurred after a CVCRI with identical micro-organisms. CVCRI [adjusted odds ratio (aOR): 5.2; 95% CI: 3.2-8.5], coronary artery bypass grafting (aOR: 2.9; 95% CI: 1.6-5.2), and obesity (aOR: 11.4; 95% CI: 1.0-130.1) were independent factors associated with SSI. The new finding of this study is that patients with CVCRI were 5.2 times more likely to develop SSI compared to patients without CVCRI. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. The Effect of Model Fidelity on Learning Outcomes of a Simulation-Based Education Program for Central Venous Catheter Insertion.

    Science.gov (United States)

    Diederich, Emily; Mahnken, Jonathan D; Rigler, Sally K; Williamson, Timothy L; Tarver, Stephen; Sharpe, Matthew R

    2015-12-01

    Simulation-based education for central venous catheter (CVC) insertion has been repeatedly documented to improve performance, but the impact of simulation model fidelity has not been described. The aim of this study was to examine the impact of the physical fidelity of the simulation model on learning outcomes for a simulation-based education program for CVC insertion. Forty consecutive residents rotating through the medical intensive care unit of an academic medical center completed a simulation-based education program for CVC insertion. The curriculum was designed in accordance with the principles of deliberate practice and mastery learning. Each resident underwent baseline skills testing and was then randomized to training on a commercially available CVC model with high physical fidelity (High-Fi group) or a simply constructed model with low physical fidelity (Low-Fi group) in a noninferiority trial. Upon completion of their medical intensive care unit rotation 4 weeks later, residents returned for repeat skills testing on the high-fidelity model using a 26-item checklist. The mean (SD) posttraining score on the 26-item checklist for the Low-Fi group was 23.8 (2.2) (91.5%) and was not inferior to the mean (SD) score for the High-Fi group of 22.5 (2.6) (86.5%) (P Simulation-based education using equipment with low physical fidelity can achieve learning outcomes comparable with those with high-fidelity equipment, as long as other aspects of fidelity are maintained and robust educational principles are applied during the design of the curriculum.

  12. [Actual questions about the prevention of venous thromboembolism in cancer patients receiving chemotherapy].

    Science.gov (United States)

    Losonczy, Hajna; Nagy, Ágnes; Tar, Attila

    2016-02-07

    Cancer patients have a 2-7 fold increased risk of venous thromboembolism compared with the general population and, since 1990, this is associated with significant morbidity and mortality. This review summarizes the current knowledge on venous thromboembolism and cancer. Notably, the risk of venous thromboembolism varies depending on the type and stage of cancer. For instance, pancreatic and brain cancer patients have a higher risk of venous thromboembolism than breast and prostate cancer patients. Moreover, patients with metastatic disease have a higher risk than those with localized tumors. Tumor-derived procoagulant factors, cytokines and growth factors may directly and indirectly enhance venous thromboembolism. Chemotherapy produces ~6,5 fold increase in venous thromboembolism incidence in cancer patients compared to the general population. Prevention of this complication is challenging. The authors review the development of guidelines concerning venous thromboembolism prevention in hospitalized and also in ambulatory cancer patients treated with chemotherapy. Current guidelines recommend the use of low-molecular-weight heparin. Understanding the underlying mechanisms may allow the development of new therapies to safely prevent venous thromboembolism in cancer patients.

  13. Rivaroxaban or Aspirin for Extended Treatment of Venous Thromboembolism

    NARCIS (Netherlands)

    Weitz, Jeffrey I.; Lensing, Anthonie W. A.; Prins, Martin H.; Bauersachs, Rupert; Beyer-Westendorf, Jan; Bounameaux, Henri; Brighton, Timothy A.; Cohen, Alexander T.; Davidson, Bruce L.; Decousus, Hervé; Freitas, Maria C. S.; Holberg, Gerlind; Kakkar, Ajay K.; Haskell, Lloyd; van Bellen, Bonno; Pap, Akos F.; Berkowitz, Scott D.; Verhamme, Peter; Wells, Philip S.; Prandoni, Paolo; Bianchi, Alessandra; Brighton, Tim; Carroll, Patrick; Chong, Beng; Chunilal, Sanjeev; Coughlin, Paul; Curnow, Jennifer; Jackson, David; Tran, Huyen; Ward, Chris; Brodmann, Marianne; Kyrle, Paul; Marschang, Peter; Petkov, Ventzislav; Hainaut, Philippe; Jordens, Paul; Vandekerkhof, Jos; Wautrecht, Jean-Claude; Annichino-Bizzacchi, Joyce; Correa, Joao; Cukier, Alberto; Freire, Antonio; Pereira, Adamastor; Porto, Carmen; Sacilotto, Roberto; Vasconcelos Costa, Agenor; Della Siega, Anthony; Dolan, Sean; Le Gal, Gré goire; Middeldorp, Saskia

    2017-01-01

    BACKGROUND Although many patients with venous thromboembolism require extended treatment, it is uncertain whether it is better to use full- or lower-intensity anticoagulation therapy or aspirin. METHODS In this randomized, double-blind, phase 3 study, we assigned 3396 patients with venous

  14. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Science.gov (United States)

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  15. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    Science.gov (United States)

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  16. Complication of venous thrombosis of the lower extremities with pulmonary embolism

    International Nuclear Information System (INIS)

    Suzuki, Teruyasu; Morita, Rikushi

    1993-01-01

    We studied the relationship between the complication of the pulmonary embolism and the localization of the venous thrombus in the lower extremities using Tc-99m macroaggregated albumin (MAA) venography. Tc-99m MAA venography clearly demonstrated most of the deep and superficial veins from the leg to the pelvis and the abdomen. The incidence of venous thrombosis was highest in the pelvic veins (28.8%), and second in the superficial leg veins (10.9%). The complication of pulmonary embolism was highest in the pelvic venous thrombosis (20.4%), and second in the femoral venous thrombosis (16.0%). (author)

  17. Venous Thromboembolism and Risk of Idiopathic Interstitial Pneumonia A Nationwide Study

    DEFF Research Database (Denmark)

    Sode, Birgitte Margareta; Dahl, Morten; Nielsen, Sune Fallgaard

    2010-01-01

    Rationale: Idiopathic interstitial pneumonia is characterized by pulmonary fibrosis and high mortality. Objectives: We examined the association between ever-diagnosed venous thromboembolism and risk of incident idiopathic interstitial pneumonia. Venous thromboembolism was taken as a proxy...... Danish registries. Measurements and Main Results: Age-standardized incidence rates per 10,000 person-years for idiopathic interstitial pneumonia were higher among those ever diagnosed with venous thromboembolism (1.8; n = 158,676), pulmonary embolism (2.8; n = 70,586), and deep venous thrombosis only (1.......2; n = 88,090), than among control subjects (0.8; n = 7,260,278). Multivariate-adjusted hazard ratios for idiopathic interstitial pneumonia were 1.8 (95% confidence interval [Cl], 1.7-1.9) in those ever diagnosed with venous thromboembolism, 2.4 (95% CI, 2.3-2.6) in those ever diagnosed with pulmonary...

  18. Duplex correlation phlebography in venous mapping of the upper limbs for artery venous fistulas for hemodialysis

    International Nuclear Information System (INIS)

    Esperon Percovich, A.; Lopez Chapuis, D.; Velverdu, M.; Curi, J.; Sciuto, F.; Velverdu, M.; Curi, J.

    1995-01-01

    When clinical evaluation is not enough,the evaluation of the venous condition of the upper limbs for the realization of angio access for hemodialysis is classically based on phlebography,an invasive,risky method.the appear rance of non invasive techniques such as eco Doppler(duplex) makes it necessary to do research in order to determine the utility of the method and define its indications.The authors analyse 35 venous mappings of the upper limbs by phlebography and duplex and compare its results for the different venous regions.They come to the conclusion that duplex presented the best performance for the hum ero axillary subclavian region,detecting thrombosis with a sensitivity of 100% a specificity of 97% positive predictive value of 50% and negative predictive value of 100%.For superficial axis (radial and superficial ulnar,basilic and cephalic)there is low sensitivity for the determination of presence and permeability of the axis but 100% specificity.Duplex was not useful for the description of veins in order to determine utility for Avf.Finally,the authors make recommendations as regards indications of these para clinical tests [es

  19. Near-infrared vascular imaging in peripheral venous and arterial access

    OpenAIRE

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development and clinical evaluation of the VascuLuminator, a guidance tool for peripheral venous and arterial access by visualizing blood vessels underneath the skin with near-infrared light. In a third to a fif...

  20. The effect of ankle joint immobilization on lower limb venous flow.

    Science.gov (United States)

    Craik, Johnathan D; Clark, Amanda; Hendry, James; Sott, Andrea H; Hamilton, Paul D

    2015-01-01

    Below-knee cast immobilization is associated with an increased risk of developing deep vein thrombosis secondary to venous stasis. We investigated the effect of weight-bearing in a below-knee cast or pneumatic walking boot on lower limb venous blood flow. Duplex ultrasonography was used to measure venous blood flow in the popliteal vein of 10 healthy volunteers. Venous blood flow was measured while at rest, ambulating non-weight-bearing, partial weight-bearing, and full weight-bearing. Measurements were performed without ankle joint immobilization, with the ankle immobilized in a neutral cast, and with the ankle immobilized in a pneumatic walking boot in both neutral and equinus. There was no significant reduction in venous blood flow measurements between full weight-bearing without ankle joint immobilization and full weight-bearing in a neutral cast or neutral pneumatic walking boot. However, venous blood flow was reduced when partial weight-bearing (50%) and when full weight-bearing in a pneumatic walking boot in equinus. These results demonstrate that venous blood flow returned to normal levels when the subjects were permitted to fully bear weight in below-knee casts or walking boots, provided that the ankle joint was not in equinus. Weight-bearing status and ankle joint position should be appreciated during decisions for the provision of chemical thromboprophylaxis. © The Author(s) 2014.

  1. Urinary hemosiderin: role in evaluation of chronic venous insufficiency

    Directory of Open Access Journals (Sweden)

    Ashish Lal Shrestha

    2012-08-01

    Full Text Available Chronic venous insufficiency (CVI leads to skin changes with dermal hemosiderin deposition. We studied the presence of hemosiderin in the urine to assess if this could be used as a biochemical marker for CVI. Hereby we present a case control study conducted in a tertiary care centre in South India. There were 100 cases with evidence of advanced CVI (the Clinical-Etiology-Anatomy-Pathophysiology classification: C5, C6 confirmed by duplex scanning. Controls were 50 patients with leg ulcers due to other etiologies. All patients were subjected to urinary hemosiderin testing. In all 100 patients with CVI (C5 and C6 disease axial venous reflux was confirmed by duplex ultrasound. Superficial venous reflux was noted in 71% of patients and deep venous reflux in 54.%. Primary venous insufficiency was the etiology in 81% of patients. Only 4/100 patients had detectable amounts of hemosiderin in the urine. Urine hemosiderin testing to determine presence or absence of CVI yielded the following values: positive predictive value-80%; negative predictive value-33%; sensitivity-4% and specificity-98%. The test could not be recommended as a marker of CVI. In Indian patients urinary hemosiderin is not a useful screening test in CVI.

  2. Venous and arterial thrombosis: Two aspects of the same disease?

    Directory of Open Access Journals (Sweden)

    Paolo Prandoni

    2009-01-01

    Full Text Available Paolo PrandoniDepartment of Cardiothoracic and Vascular Sciences, Thromboembolism Unit, University Hospital of Padua Padua, ItalyAbstract: An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice.Keywords: venous thromboembolism, deep vein thrombosis, pulmonary embolism, myocardial infarction, ischemic stroke, atherosclerosis

  3. Central vein perforation during tunneled dialysis catheter insertion: principles of acute management.

    Science.gov (United States)

    Pua, Uei

    2014-10-01

    Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.

  4. Iliac Vein Interrogation Augments Venous Ulcer Healing in Patients Who Have Failed Standard Compression Therapy along with Pathological Venous Closure.

    Science.gov (United States)

    Mousa, Albeir Y; Broce, Mike; Yacoub, Michael; AbuRahma, Ali F

    2016-07-01

    Treatment of venous ulcers is demanding for patients, as well as clinicians, and the investigation of underlying venous hypertension is the cornerstone of therapy. We propose that occult iliac vein stenosis should be ruled out by iliac vein interrogation (IVI) in patients with advanced venous stasis. We conducted a systematic retrospective analysis of a consecutive series of patients who presented with CEAP (clinical, etiological, anatomical, and pathophysiological) 6 venous disease. All patients had great saphenous vein ablation, compressive treatment, wound care (including Unna boot compression), and perforator closure using ablation therapy. Iliac vein stenosis was defined as ≥50% stenosis in cross-sectional surface area on intravascular ultrasound. Primary outcomes include time of venous ulcer healing and/or measurable change in the Venous Clinical Severity Score. Twenty-two patients with CEAP 6 venous disease met the inclusion criteria (active ulcers >1.5 cm in diameter). The average age and body mass index were 62.2 ± 9.2 years and 41.7 ± 16.7, respectively. The majority were female (72.7%) with common comorbidities, such as hyperlipidemia (54.5%), hypertension (36.4%), and diabetes mellitus (27.3%). Twenty-nine ulcers with an average diameter of 3.4 ± 1.9 cm and a depth of 2.2 ± 0.5 mm were treated. The majority of the ulcers occurred on the left limb (n = 17, 58.6%). Average perforator venous reflux was 3.6 ± 0.8 sec, while common femoral reflux was 1.8 ± 1.6. The majority (n = 19, 64.5%) of the perforator veins were located at the base of the ulcer, while the remainder (n = 10, 34.5%) were within 2 cm from the base. Of the 13 patients who underwent IVI, 8 patients (61.5%) had stenosis >50% that was corrected with iliac vein angioplasty and stenting (IVAS). There was a strong trend toward shorter healing time in the IVI group (7.9 ± 9.5 weeks) than for patients in the no iliac vein interrogation (NIVI) group (20.2 ± 15

  5. Deep venous thrombosis like puerperium complication: two cases

    International Nuclear Information System (INIS)

    Martin Gomez, J.I.; Larena Iturbe, J.A.; Zuazo Ojeda, M.A.; Pena Sarnago, J.M.

    1994-01-01

    Deep venous thrombosis, especially that of the ovarian vein, is a rare, potentially fatal complication that can present during the puerperium, its clinical diagnosis is not easy, thus dangerously delaying specific treatment. Two cases are presented of deep venous thrombosis diagnosed on the basis of computerized tomography (CT) in puerperal patients with symptoms of postpartum pain and fever. (Author) 9 refs

  6. Mixed Capillary Venous Retroperitoneal Hemangioma

    Directory of Open Access Journals (Sweden)

    Mohit Godar

    2013-01-01

    Full Text Available We report a case of mixed capillary venous hemangioma of the retroperitoneum in a 61-year-old man. Abdominal ultrasonography showed a mass to be hypoechoic with increased flow in color Doppler imaging. Dynamic contrast-enhanced computed tomography revealed a centripetal filling-in of the mass, located anterior to the left psoas muscle at the level of sacroiliac joint. On the basis of imaging features, preoperative diagnosis of hemangioma was considered and the mass was excised by laparoscopic method. Immunohistochemical studies were strongly positive for CD31 and CD34, and negative for calretinin, EMA, WT1, HMB45, Ki67, synaptophysin, and lymphatic endothelial cell marker D2–40. Histologically, the neoplasm was diagnosed as mixed capillary venous hemangioma.

  7. rCBF measurement by one-point venous sampling with the ARG method

    International Nuclear Information System (INIS)

    Yoshida, Nobuhiro; Okamoto, Toshiaki; Takahashi, Hidekado; Hattori, Teruo

    1997-01-01

    We investigated the possibility of using venous blood sampling instead of arterial blood sampling for the current method of ARG (autoradiography) used to determine regional cerebral blood flow (rCBF) on the basis of one session of arterial blood sampling and SPECT. For this purpose, the ratio of the arterial blood radioactivity count to the venous blood radioactivity count, the coefficient of variation, and the correlation and differences between arterial blood-based rCBF and venous blood-based rCBF were analyzed. The coefficient of variation was lowest (4.1%) 20 minutes after injection into the dorsum manus. When the relationship between venous and arterial blood counts was analyzed, arterial blood counts correlated well with venous blood counts collected at the dorsum manus 20 or 30 minutes after intravenous injection and with venous blood counts collected at the wrist 20 minutes after intravenous injection (r=0.97 or higher). The difference from rCBF determined on the basis of arterial blood was smallest (0.7) for rCBF determined on the basis of venous blood collected at the dorsum manus 20 minutes after intravenous injection. (author)

  8. Regular sports activities decrease the risk of venous thrombosis

    NARCIS (Netherlands)

    van Stralen, K. J.; le Cessie, S.; Rosendaal, F. R.; Doggen, C. J. M.

    2007-01-01

    BACKGROUND: Stasis of the blood has been postulated as a major cause of venous thrombosis. However, little is known about the effect of stimulating the blood flow in order to prevent venous thrombosis through, for example, sports activities. OBJECTIVES: In a large population-based case-control study

  9. Jugular venous pooling during lowering of the head affects blood pressure of the anesthetized giraffe.

    Science.gov (United States)

    Brøndum, E; Hasenkam, J M; Secher, N H; Bertelsen, M F; Grøndahl, C; Petersen, K K; Buhl, R; Aalkjaer, C; Baandrup, U; Nygaard, H; Smerup, M; Stegmann, F; Sloth, E; Ostergaard, K H; Nissen, P; Runge, M; Pitsillides, K; Wang, T

    2009-10-01

    How blood flow and pressure to the giraffe's brain are regulated when drinking remains debated. We measured simultaneous blood flow, pressure, and cross-sectional area in the carotid artery and jugular vein of five anesthetized and spontaneously breathing giraffes. The giraffes were suspended in the upright position so that we could lower the head. In the upright position, mean arterial pressure (MAP) was 193 +/- 11 mmHg (mean +/- SE), carotid flow was 0.7 +/- 0.2 l/min, and carotid cross-sectional area was 0.85 +/- 0.04 cm(2). Central venous pressure (CVP) was 4 +/- 2 mmHg, jugular flow was 0.7 +/- 0.2 l/min, and jugular cross-sectional area was 0.14 +/- 0.04 cm(2) (n = 4). Carotid arterial and jugular venous pressures at head level were 118 +/- 9 and -7 +/- 4 mmHg, respectively. When the head was lowered, MAP decreased to 131 +/- 13 mmHg, while carotid cross-sectional area and flow remained unchanged. Cardiac output was reduced by 30%, CVP decreased to -1 +/- 2 mmHg (P blood in the veins. When the head was raised, the jugular veins collapsed and blood was returned to the central circulation, and CVP and cardiac output were restored. The results demonstrate that in the upright-positioned, anesthetized giraffe cerebral blood flow is governed by arterial pressure without support of a siphon mechanism and that when the head is lowered, blood accumulates in the vein, affecting MAP.

  10. Noncontrast computed tomographic Hounsfield unit evaluation of cerebral venous thrombosis: a quantitative evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Besachio, David A. [University of Utah, Department of Radiology, Salt Lake City (United States); United States Navy, Bethesda, MD (United States); Quigley, Edward P.; Shah, Lubdha M.; Salzman, Karen L. [University of Utah, Department of Radiology, Salt Lake City (United States)

    2013-08-15

    Our objective is to determine the utility of noncontrast Hounsfield unit values, Hounsfield unit values corrected for the patient's hematocrit, and venoarterial Hounsfield unit difference measurements in the identification of intracranial venous thrombosis on noncontrast head computed tomography. We retrospectively reviewed noncontrast head computed tomography exams performed in both normal patients and those with cerebral venous thrombosis, acquiring Hounsfield unit values in normal and thrombosed cerebral venous structures. Also, we acquired Hounsfield unit values in the internal carotid artery for comparison to thrombosed and nonthrombosed venous structures and compared the venous Hounsfield unit values to the patient's hematocrit. A significant difference is identified between Hounsfield unit values in thrombosed and nonthrombosed venous structures. Applying Hounsfield unit threshold values of greater than 65, a Hounsfield unit to hematocrit ratio of greater than 1.7, and venoarterial difference values greater than 15 alone and in combination, the majority of cases of venous thrombosis are identifiable on noncontrast head computed tomography. Absolute Hounsfield unit values, Hounsfield unit to hematocrit ratios, and venoarterial Hounsfield unit value differences are a useful adjunct in noncontrast head computed tomographic evaluation of cerebral venous thrombosis. (orig.)

  11. Noncontrast computed tomographic Hounsfield unit evaluation of cerebral venous thrombosis: a quantitative evaluation

    International Nuclear Information System (INIS)

    Besachio, David A.; Quigley, Edward P.; Shah, Lubdha M.; Salzman, Karen L.

    2013-01-01

    Our objective is to determine the utility of noncontrast Hounsfield unit values, Hounsfield unit values corrected for the patient's hematocrit, and venoarterial Hounsfield unit difference measurements in the identification of intracranial venous thrombosis on noncontrast head computed tomography. We retrospectively reviewed noncontrast head computed tomography exams performed in both normal patients and those with cerebral venous thrombosis, acquiring Hounsfield unit values in normal and thrombosed cerebral venous structures. Also, we acquired Hounsfield unit values in the internal carotid artery for comparison to thrombosed and nonthrombosed venous structures and compared the venous Hounsfield unit values to the patient's hematocrit. A significant difference is identified between Hounsfield unit values in thrombosed and nonthrombosed venous structures. Applying Hounsfield unit threshold values of greater than 65, a Hounsfield unit to hematocrit ratio of greater than 1.7, and venoarterial difference values greater than 15 alone and in combination, the majority of cases of venous thrombosis are identifiable on noncontrast head computed tomography. Absolute Hounsfield unit values, Hounsfield unit to hematocrit ratios, and venoarterial Hounsfield unit value differences are a useful adjunct in noncontrast head computed tomographic evaluation of cerebral venous thrombosis. (orig.)

  12. [Sequelae of unilateral deep venous thrombosis in plethysmography of the calf].

    Science.gov (United States)

    Zicot, M; Depairon, M

    1982-01-01

    Twenty four patients suffering from unilateral venous disturbances revealed by Doppler and secondary to a deep venous thrombosis were examined. The calf venous haemodynamics was analyzed by use of a strain-jauge plethysmograph. We determined the increase in venous volume due to the inflation of a thigh pneumatic cuff (pressure at 20, 40 and 60 mm Hg; delta V20, delta V40, delta V60). The maximal venous output (Vout) was measured after a quick release of the 60 mm Hg pressure. The maximal venous drainage (VMM) was assessed during a rhythmic exercise (tiptoeing) while standing; delta V20, delta V40 and delta V60 were nearly constantly reduced on the abnormal side (t of Student respectively 3.49; 6.09 and 5.07). Vout dropped proportionaly to delta V60. Some abnormalities due to valvular insufficiency were frequently present in the beginning of the inflation curve at the level of the abnormal limbs. VMM was nearly always largely decreased on the affected side (t = 5.43). The unilateral flow disturbances displayed by the Doppler were regularly going with abnormalities of the capacitive system, well demonstrated by comparison with the non-affected limbs.

  13. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.

  14. A Factor Increasing Venous Contamination on Bolus Chase Three-dimensional Magnetic Resonance Imaging: Charcot Neuroarthropathy.

    Science.gov (United States)

    Çildağ, Mehmet B; Ertuğrul, Mustafa B; Köseoğlu, Ömer Fk; Armstrong, David G

    2018-01-01

    The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN). Bolus-chase three-dimensional magnetic resonance (MR) of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A), patients with diabetic foot ulcers (Group B) and patients with CN accompanying diabetic foot ulcers (Group C). Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Venous contamination following bolus chase MR was higher in patients with CN.

  15. Upper extremity deep venous thrombosis after port insertion: What are the risk factors?

    Science.gov (United States)

    Tabatabaie, Omidreza; Kasumova, Gyulnara G; Kent, Tara S; Eskander, Mariam F; Fadayomi, Ayotunde B; Ng, Sing Chau; Critchlow, Jonathan F; Tawa, Nicholas E; Tseng, Jennifer F

    2017-08-01

    Totally implantable venous access devices (ports) are widely used, especially for cancer chemotherapy. Although their use has been associated with upper extremity deep venous thrombosis, the risk factors of upper extremity deep venous thrombosis in patients with a port are not studied adequately. The Healthcare Cost and Utilization Project's Florida State Ambulatory Surgery and Services Database was queried between 2007 and 2011 for patients who underwent outpatient port insertion, identified by Current Procedural Terminology code. Patients were followed in the State Ambulatory Surgery and Services Database, State Inpatient Database, and State Emergency Department Database for upper extremity deep venous thrombosis occurrence. The cohort was divided into a test cohort and a validation cohort based on the year of port placement. A multivariable logistic regression model was developed to identify risk factors for upper extremity deep venous thrombosis in patients with a port. The model then was tested on the validation cohort. Of the 51,049 patients in the derivation cohort, 926 (1.81%) developed an upper extremity deep venous thrombosis. On multivariate analysis, independently significant predictors of upper extremity deep venous thrombosis included age deep venous thrombosis (odds ratio = 1.77), all-cause 30-day revisit (odds ratio = 2.36), African American race (versus white; odds ratio = 1.86), and other nonwhite races (odds ratio = 1.35). Additionally, compared with genitourinary malignancies, patients with gastrointestinal (odds ratio = 1.55), metastatic (odds ratio = 1.76), and lung cancers (odds ratio = 1.68) had greater risks of developing an upper extremity deep venous thrombosis. This study identified major risk factors of upper extremity deep venous thrombosis. Further studies are needed to evaluate the appropriateness of thromboprophylaxis in patients at greater risk of upper extremity deep venous thrombosis. Copyright © 2017 Elsevier Inc

  16. Thrombin Avtivable Fibrinolysis Inhibitor in Venous and Arterial Thrombosis

    NARCIS (Netherlands)

    E.L.E. de Bruijne

    2011-01-01

    textabstractVenous and arterial thromboses are major causes of morbidity and mortality. Venous thrombosis is the result of pathological occlusive clot formation in the veins. It occurs mainly in the deep veins of the leg (deep vein thrombosis), from which parts of the clot frequently embolize to the

  17. Venous muscle pump function during pregnancy. Assessment by ambulatory strain-gauge plethysmography

    DEFF Research Database (Denmark)

    Struckmann, J R; Meiland, H; Bagi, P

    1990-01-01

    The venous muscle pump function was quantitatively assessed through pregnancy weeks 16, 30, 38 and 3 months (week 53) following delivery, in 24 pregnant women who completed a normal pregnancy. A statistically significant increase was found in the mean venous reflux (P less than 0.01), which was r...... primarily by mechanical obstruction, or hormonal influence other than that of estradiol, estriol or progesterone. 17% (4.7-37%) of the women with a normal pregnancy developed a pathological venous muscle pump function....... virtually disappeared post partum, corresponding to the muscle pump normalization. No statistical correlation was found between venous muscle pump values and changes in hormone concentrations of estradiol, estriol and progesterone. It is suggested that venous insufficiency development in pregnancy is caused...

  18. Imaging diagnosis of venous malformation in head and neck

    International Nuclear Information System (INIS)

    Ha, Doo Hoe; Kim, Dong Ik; Suh, Jung Ho; Jung, Tae Sub

    1992-01-01

    The venous malformation in head and neck is a development vascular disease which arises from the arrest in the certain stage of vascular embryogenesis. However, the lesion extends along the fascia and has a tendency to recur after incomplete therapy. Retrospectively, the authors reviewed radiologic studies of 20 patients diagnosed as venous malformation during the last 5 years. The diagnosis was verified by histopathology (5 patients) and direct puncture angiography (15 patients). The radiologic studies included. CT with intravenous contrast injection (20 patients), RI angiography with 99mTc-pyrophosphate (6 patients), and direct puncture angiography (15 patients). Multiplicity of venous malformation was noted in 9 patients. On CT scan, the lesions had lobulated irregular shape, with heterogeneous appearance, showed delayed enhancing characteristics, and had the phleboliths (21 lesions). The venous malformations were located at the masticator space (including masseter muscle) (n = 12), retrobulbar space (n 6), submandibular space (n = 4), paravertebral space (n = 3) and so on. In two cases, the lesions were very extensive involving entire neck and parapharynx. On RI angiography using 99m Tc-pyrophosphate, all of the lesions showed persistent and delayed uptake. With direct puncture angiography the lesions could be classified as acinar pattern (n = 17) and mixed pattern (acinar and saccular) (n = 2). Venous connections were noted in 10 lesions. In conclusion, if a soft tissue mass on head and neck shows a heterogeneous attenuation density with or without calcified phlebolith on CT scan, RI angiography is recommended as a next diagnostic study. If it shows delayed persistent uptake, venous malformation can be suspected. Finally direct puncture angiography can verify the nature and extent of the lesion

  19. Comparison of Venous Return Characteristics with Right Ventricular Mechanics During Cephalic Fluid Shift

    Science.gov (United States)

    Elliott, Morgan; Martin, David

    2015-01-01

    For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail

  20. Acute Mesenteric Venous Thrombosis with a Vaginal Contraceptive Ring

    Directory of Open Access Journals (Sweden)

    Wesley Eilbert

    2014-07-01

    Full Text Available Mesenteric venous thrombosis is a rare cause of abdominal pain, which if left untreated may result in bowel infarction, peritonitis and death. The majority of patients with this illness have a recognizable, predisposing prothrombotic condition. Oral contraceptives have been identified as a predisposing factor for mesenteric venous thrombosis in reproductive-aged women. In the last fifteen years new methods of hormonal birth control have been introduced, including a transdermal patch and an intravaginal ring. In this report, we describe a case of mesenteric venous thrombosis in a young woman caused by a vaginal contraceptive ring. [West J Emerg Med. 2014;15(4:395-397.