WorldWideScience

Sample records for central receiver power plants

  1. Central receiver power plant: an environmental, ecological, and socioeconomic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Davison, M.; Grether, D.

    1977-06-01

    The technical details of the central receiver design are reviewed. Socio-economic questions are considered including: market penetration, air industrial sector model, demands on industry, employment, effluents associated with manufacture of components, strains due to intensive construction, water requirements, and land requirements. The ecological effects in the vicinity of the central receiver plant site are dealt with, with emphasis on effects on land surface, mammals, and reptiles and amphibians. Climatological considerations are reviewed including: desert types, effects of surface albedo modification, effects of aerosols, effects on evaporation rates, the heliostat canopy, effects on turbulent transfer rates, effects on the wind profile, a model of convection about a central receiver plant, and a global scenario. Drawings of heliostat and plant design are included in appendices. (MHR)

  2. Baseload Nitrate Salt Central Receiver Power Plant Design Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Tilley, Drake [Abengoa Solar LLC, Lakewood, CO (United States); Kelly, Bruce [Abengoa Solar LLC, Lakewood, CO (United States); Burkholder, Frank [Abengoa Solar LLC, Lakewood, CO (United States)

    2014-12-12

    The objectives of the work were to demonstrate that a 100 MWe central receiver plant, using nitrate salt as the receiver coolant, thermal storage medium, and heat transport fluid in the steam generator, can 1) operate, at full load, for 6,400 hours each year using only solar energy, and 2) satisfy the DOE levelized energy cost goal of $0.09/kWhe (real 2009 $). To achieve these objectives the work incorporated a large range of tasks relating to many different aspects of a molten salt tower plant. The first Phase of the project focused on developing a baseline design for a Molten Salt Tower and validating areas for improvement. Tasks included a market study, receiver design, heat exchanger design, preliminary heliostat design, solar field optimization, baseline system design including PFDs and P&IDs and detailed cost estimate. The baseline plant met the initial goal of less than $0.14/kWhe, and reinforced the need to reduce costs in several key areas to reach the overall $0.09/kWhe goal. The major improvements identified from Phase I were: 1) higher temperature salt to improve cycle efficiency and reduce storage requirements, 2) an improved receiver coating to increase the efficiency of the receiver, 3) a large receiver design to maximize storage and meet the baseload hours objective, and 4) lower cost heliostat field. The second Phase of the project looked at advancing the baseline tower with the identified improvements and included key prototypes. To validate increasing the standard solar salt temperature to 600 °C a dynamic test was conducted at Sandia. The results ultimately proved the hypothesis incorrect and showed high oxide production and corrosion rates. The results lead to further testing of systems to mitigate the oxide production to be able to increase the salt temperature for a commercial plant. Foster Wheeler worked on the receiver design in both Phase I and Phase II looking at both design and lowering costs utilizing commercial fossil boiler

  3. Master Control and Data Acquisition System for a Solar Central Receiver Electric Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Soderstrand, M.A. (Sandia Labs., Albuquerque, NM); Darsey, D.M. (Aerospace Corp., El Segundo, CA); Rountree, R.C. (California Univ., Livermore); Sheahan, R.R. (Southern California Edison Co., Los Angeles)

    1979-09-01

    A design of the 10-megawatt electric Solar Central Receiver Power Plant currently under construction in Barstow, California is described. Consideration is given to the collector, receiver, and thermal storage subsystems. The circuits and systems concepts related to the Master Control and Data Acquisition Systems are emphasized. Implementation of the Master Control Subsystem, operational requirements, and software are discussed along with its status and expectations.

  4. Thermoeconomic optimization of a Kalina cycle for a central receiver concentrating solar power plant

    DEFF Research Database (Denmark)

    Modi, Anish; Kærn, Martin Ryhl; Andreasen, Jesper Graa

    2016-01-01

    Concentrating solar power plants use a number of reflecting mirrors to focus and convert the incident solar energy to heat, and a power cycle to convert this heat into electricity. This paper evaluates the use of a high temperature Kalina cycle for a central receiver concentrating solar power plant...... and the economic perspectives, the results suggest that it is not beneficial to use the Kalina cycle for high temperature concentrating solar power plants....... with direct vapour generation and without storage. The use of the ammonia-water mixture as the power cycle working fluid with non-isothermal evaporation and condensation presents the potential to improve the overall performance of the plant. This however comes at a price of requiring larger heat exchangers...

  5. Design and thermal analysis of a direct steam generation central-receiver solar thermal power plant

    OpenAIRE

    Garrido Camino, Carlos

    2013-01-01

    Thermo-solar central receiver power plants use radiation coming from the Sun, a clean energy source, to produce electricity. The best locations for this type of installations are the ones between 30º and 40º of latitude, both in the northern and southern hemisphere, what makes Spain to be one of the most suitable and attractive places all over the world for this energy source. However, this technology is not well developed yet comparing to other renewable energy sources such as wind energy or...

  6. Transient analysis of a molten salt central receiver (MSCR) in a solar power plant

    Science.gov (United States)

    Joshi, A.; Wang, C.; Akinjiola, O.; Lou, X.; Neuschaefer, C.; Quinn, J.

    2016-05-01

    Alstom is developing solar power tower plants utilizing molten salt as the working fluid. In solar power tower, the molten salt central receiver (MSCR) atop of the tower is constructed of banks of tubes arranged in panels creating a heat transfer surface exposed to the solar irradiation from the heliostat field. The molten salt heat transfer fluid (HTF), in this case 60/40%wt NaNO3-KNO3, flows in serpentine flow through the surface collecting sensible heat thus raising the HTF temperature from 290°C to 565°C. The hot molten salt is stored and dispatched to produce superheated steam in a steam generator, which in turn produces electricity in the steam turbine generator. The MSCR based power plant with a thermal energy storage system (TESS) is a fully dispatchable renewable power plant with a number of opportunities for operational and economic optimization. This paper presents operation and controls challenges to the MSCR and the overall power plant, and the use of dynamic model computer simulation based transient analyses applied to molten salt based solar thermal power plant. This study presents the evaluation of the current MSCR design, using a dynamic model, with emphasis on severe events affecting critical process response, such as MS temperature deviations, and recommend MSCR control design improvements based on the results. Cloud events are the scope of the transient analysis presented in this paper. The paper presents results from a comparative study to examine impacts or effects on key process variables related to controls and operation of the MSCR plant.

  7. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume II. Plant specifications

    Energy Technology Data Exchange (ETDEWEB)

    Price, R. E.

    1983-12-31

    The specifications and design criteria for all plant systems and subsystems used in developing the preliminary design of Carrisa Plains 30-MWe Solar Plant are contained in this volume. The specifications have been organized according to plant systems and levels. The levels are arranged in tiers. Starting at the top tier and proceeding down, the specification levels are the plant, system, subsystem, components, and fabrication. A tab number, listed in the index, has been assigned each document to facilitate document location.

  8. Optimisation of a Kalina cycle for a central receiver solar thermal power plant with direct steam generation

    DEFF Research Database (Denmark)

    Modi, Anish; Haglind, Fredrik

    2014-01-01

    Central receiver solar thermal power plants are regarded as one of the promising ways to generate electricity in near future. They offer the possibility of using high temperatures and pressures to achieve high efficiencies with standard power cycles. A direct steam generation approach can be used...... for a central receiver solar thermal power plant with direct steam generation. The variation in the cycle performance with respect to the turbine inlet ammonia mass fraction and pressure and a comparison of the initial investment with that of the basic Rankine cycle are also presented. Only high live steam...... for such plants for improved performance. This approach can also be combined with using advanced power cycles like the Kalina cycle, which uses a zeotropic mixture of ammonia and water instead of pure water as the working fluid. This paper presents the optimisation of a particular Kalina cycle layout...

  9. Performance analysis of a Kalina cycle for a central receiver solar thermal power plant with direct steam generation

    DEFF Research Database (Denmark)

    Modi, Anish; Haglind, Fredrik

    2014-01-01

    Solar thermal power plants have attracted increasing interest in the past few years - with respect to both the design of the various plant components, and extending the operation hours by employing different types of storage systems. One approach to improve the overall plant efficiency is to use...... without corroding the equipment by using suitable additives with the mixture. The purpose of the study reported here was to investigate if there is any benefit of using a Kalina cycle for a direct steam generation, central receiver solar thermal power plant with high live steam temperature (450 C...... direct steam generation with water/steam as both the heat transfer fluid in the solar receivers and the cycle working fluid. This enables operating the plant with higher turbine inlet temperatures. Available literature suggests that it is feasible to use ammonia-water mixtures at high temperatures...

  10. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume III, Book 2. Design drawings

    Energy Technology Data Exchange (ETDEWEB)

    1983-12-31

    The design of the 30 MWe central receiver solar power plant to be located at Carrisa Plains, San Luis Obispo County, California, is summarized. The plant uses a vertical flat-panel (billboard) solar receiver located at the top of a tower to collect solar energy redirected by approximately 1900 heliostats located to the north of the tower. The solar energy is used to heat liquid sodium pumped from ground level from 610 to 1050/sup 0/F. The power conversion system is a non-reheat system, cost-effective at this size level, and designed for high-efficiency performance in an application requiring daily startup. Successful completion of this project will lead to power generation starting in 1986. This report consists of design drawings for this plant.

  11. Power and Efficiency Analysis of a Solar Central Receiver Combined Cycle Plant with a Small Particle Heat Exchanger Receiver

    Science.gov (United States)

    Virgen, Matthew Miguel

    Two significant goals in solar plant operation are lower cost and higher efficiencies. To achieve those goals, a combined cycle gas turbine (CCGT) system, which uses the hot gas turbine exhaust to produce superheated steam for a bottoming Rankine cycle by way of a heat recovery steam generator (HRSG), is investigated in this work. Building off of a previous gas turbine model created at the Combustion and Solar Energy Laboratory at SDSU, here are added the HRSG and steam turbine model, which had to handle significant change in the mass flow and temperature of air exiting the gas turbine due to varying solar input. A wide range of cases were run to explore options for maximizing both power and efficiency from the proposed CSP CCGT plant. Variable guide vanes (VGVs) were found in the earlier model to be an effective tool in providing operational flexibility to address the variable nature of solar input. Combined cycle efficiencies in the range of 50% were found to result from this plant configuration. However, a combustor inlet temperature (CIT) limit leads to two distinct Modes of operation, with a sharp drop in both plant efficiency and power occurring when the air flow through the receiver exceeded the CIT limit. This drawback can be partially addressed through strategic use of the VGVs. Since system response is fully established for the relevant range of solar input and variable guide vane angles, the System Advisor Model (SAM) from NREL can be used to find what the actual expected solar input would be over the course of the day, and plan accordingly. While the SAM software is not yet equipped to model a Brayton cycle cavity receiver, appropriate approximations were made in order to produce a suitable heliostat field to fit this system. Since the SPHER uses carbon nano-particles as the solar absorbers, questions of particle longevity and how the particles might affect the flame behavior in the combustor were addressed using the chemical kinetics software Chemkin

  12. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume III, Book 1. Design description

    Energy Technology Data Exchange (ETDEWEB)

    1983-12-31

    The design of the 30 MWe central receiver solar power plant to be located at Carrisa Plains, San Luis Obispo County, California, is summarized. The plant uses a vertical flat-panel (billboard solar receiver located at the top of a tower to collect solar energy redirected by approximately 1900 heliostats located to the north of the tower. The solar energy is used to heat liquid sodium pumped from ground level from 610 to 1050/sup 0/F. The power conversion system is a non-reheat system, cost-effective at this size level, and designed for high-efficiency performance in an application requiring daily startup. Successful completion of this project will lead to power generation starting in 1986. This report discusses in detail the design of the collector system, heat transport system, thermal storage subsystem, heat transport loop, steam generation subsystem, electrical, instrumentation, and control systems, power conversion system, master control system, and balance of plant. The performance, facility cost estimate and economic analysis, and development plan are also discussed.

  13. High Flux Central Receivers of Molten Salts for the New Generation of Commercial Stand-Alone Solar Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lata, J. M.; Rodriguez, M.; Alvarez de Lara, M.

    2006-07-01

    Molten salt technology represents nowadays the most cost-effective technology for electricity generation for stand-alone Solar Power Plants. Although this technology can be applied to both concentrating technologies, Parabolic TROUGH and Central Receiver Systems (CRS), CRS technology can take advantages from its high concentration, allowing to work at high temperatures and therefore with a reduction in the size and cost of the storage system. The Receiver System is the door for which the energy passes from the field collector to the thermal-electric cycle; it represents, therefore, the core of the CRS System. SENER and CIEMAT are joining forces to face up the challenge of sizing and designing a molten salt Receiver of high thermal efficiency, able to operate at high fluxes without compromising its durability (at least 25 years). The advances in design and studies of different materials, to operate at high fluxes using molten salts as heat transfer fluid, will be presented hereafter. (Author)

  14. Evaluation of annual efficiencies of high temperature central receiver concentrated solar power plants with thermal energy storage.

    Energy Technology Data Exchange (ETDEWEB)

    Ehrhart, Brian David; Gill, David Dennis

    2013-07-01

    The current study has examined four cases of a central receiver concentrated solar power plant with thermal energy storage using the DELSOL and SOLERGY computer codes. The current state-of-the-art base case was compared with a theoretical high temperature case which was based on the scaling of some input parameters and the estimation of other parameters based on performance targets from the Department of Energy SunShot Initiative. This comparison was done for both current and high temperature cases in two configurations: a surround field with an external cylindrical receiver and a north field with a single cavity receiver. There is a fairly dramatic difference between the design point and annual average performance, especially in the solar field and receiver subsystems, and also in energy losses due to the thermal energy storage being full to capacity. Additionally, there are relatively small differences (<2%) in annual average efficiencies between the Base and High Temperature cases, despite an increase in thermal to electric conversion efficiency of over 8%. This is due the increased thermal losses at higher temperature and operational losses due to subsystem start-up and shut-down. Thermal energy storage can mitigate some of these losses by utilizing larger thermal energy storage to ensure that the electric power production system does not need to stop and re-start as often, but solar energy is inherently transient. Economic and cost considerations were not considered here, but will have a significant impact on solar thermal electric power production strategy and sizing.

  15. High-flux solar absorber concept for central receiver power plants

    Science.gov (United States)

    Pomeroy, B. D.; Roberts, J. M.; Narayanan, T. V.

    1981-02-01

    For cylindrical receivers with a capacity of about 400 MW/t, an aim-at-the belt focusing strategy can produce average fluxes the order of 0.5 MW/sq m with peaks as high as 2 MW/sq m. An absorber concept is described which uses liquid sodium coolant and a three-header configuration to efficiently capture this solar power. The mechanical design of this absorber is discussed and thermal performance estimates are presented showing the solar-capture efficiency over a range of solar intensities. The sodium-flow characteristics and some potential flow-control problems are also described. A thermal-stress analysis is presented which shows that a limiting factor on the flux capability may be tube-wall creep/fatigue failure and not the heat-transfer capability of sodium.

  16. Central Receiver Solar Thermal Power System, Phase 1. CDRL Item 2. Pilot Plant preliminary design report. Volume III, Book 1. Collector subsystem

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    The central receiver system consists of a field of heliostats, a central receiver, a thermal storage unit, an electrical power generation system, and balance of plant. This volume discusses the collector field geometry, requirements and configuration. The development of the collector system and subsystems are discussed and the selection rationale outlined. System safety and availability are covered. Finally, the plans for collector portion of the central receiver system are reviewed.

  17. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume III, Book 3. Appendices. Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S. K.

    1983-12-31

    The auxiliary heat transport systems of the Carrisa Plains Solar Power Plant (CPSPP) comprise facilities which are used to support plant operation and provide plant safety and maintenance. The facilities are the sodium purification system, argon cover gas system, sodium receiving and filling system, sodium-water reaction product receiving system, and safety and maintenance equipment. The functions of the facilities of the auxiliary system are described. Design requirements are established based on plant operating parameters. Descriptions are given on the system which will be adequate to perform the function and satisfy the requirements. Valve and equipment lists are included in the appendix.

  18. Conceptual design of advanced central receiver power systems sodium-cooled receiver concept. Volume 4. Commercial and pilot plant cost data. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    This volume of the advanced central receiver final report presents the cost data using the cost breakdown structure identified in the preliminary specification. Cost summaries are presented in the following sections for the 100-MWe and 281-MWe commercial plant and a 10-MWe pilot plant. Cost substantiation data for this volume are presented in the appendices. Other cost summary data include Nth plant data for the 100-MWe and 281-MWe commercial plants, and a summary for the alternative concept air-rock storage system. The main description of the plant costing technique occurs as part of Section II for the 100-MWe baseline concept.

  19. Solar central receiver hybrid - A cost effective future power alternative

    Science.gov (United States)

    Beshore, D. G.; Bolton, C. N.; Montague, J. E.

    1980-05-01

    System analyses and conceptual designs of solar central receiver hybrid concepts using molten salt (60% NaNO3, 40% KNO3 by weight) and fossil fired nonsolar energy sources (coal, oil, or gas) have been performed. Analyses have developed plant configurations with various solar energy storage capacities and fossil fuels. Economic analyses support the final configuration selection based on minimization of the cost of energy produced from the plant. A 500 MWe commercial plant size installed for a 1990 initial year of operation is competitive with new coal, oil, and nuclear power generation sources. This hybrid plant will save an estimated 5 million barrels of oil per year.

  20. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume III, Book 3. Appendices, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Mouradian, E. M.

    1983-12-31

    Thermal analyses for the preliminary design phase of the Receiver of the Carrizo Plains Solar Power Plant are presented. The sodium reference operating conditions (T/sub in/ = 610/sup 0/F, T/sub out/ = 1050/sup 0/F) have been considered. Included are: Nominal flux distribution on receiver panal, Energy input to tubes, Axial temperature distribution; sodium and tubes, Sodium flow distribution, Sodium pressure drop, orifice calculations, Temperature distribution in tube cut (R-0), Backface structure, and Nonuniform sodium outlet temperature. Transient conditions and panel front face heat losses are not considered. These are to be addressed in a subsequent design phase. Also to be considered later are the design conditions as variations from the nominal reference (operating) condition. An addendum, designated Appendix C, has been included describing panel heat losses, panel temperature distribution, and tube-manifold joint thermal model.

  1. An artificial vision-based control system for automatic heliostat positioning offset correction in a central receiver solar power plant

    Energy Technology Data Exchange (ETDEWEB)

    Berenguel, M. [Universidad de Almeria, Dept. de Lenguajes y Computacion, La Canada Almeria (Spain); Rubio, F.R.; Lara, P.J.; Arahal, M.R.; Camacho, E.F.; Lopez, M. [Universidad de Sevilla, Dept. de Ingenieria de Sistemas y Automatica, Sevilla (Spain); Valverde, A. [Plataforma Solar de Almeria (PSA-CIEMAT), Tabernas (Almeria) (Spain)

    2004-07-01

    This paper presents the development of a simplified and automatic heliostat positioning offset correction control system using artificial vision techniques and common CCD devices. The heliostats of a solar power plant reflect solar radiation onto a receiver (in this case, a volumetric receiver) placed at the top of a tower in order to provide a desired energy flux distribution correlated with the coolant flow (in this case air mass flow) through the receiver, usually in an open loop control configuration. There exist error sources that increase the complexity of the control system, some of which are systematic ones, mainly due to tolerances, wrong mirror facets alignment (optical errors), errors due to the approximations made when calculating the solar position, etc., that produce errors (offsets) in the heliostat orientation (aiming point). The approximation adopted in this paper is based on the use of a B/W CCD camera to correct these deviations in an automatic way imitating the same procedure followed by the operators. The obtained images are used to estimate the distance between the sunbeam centroid projected by the heliostats and a target placed on the tower, this distance thus is used for low accuracy offset correction purposes. Basic threshold-based image processing techniques are used for automatic correction. (Author)

  2. Conceptual design of advanced central receiver power systems sodium-cooled receiver concept. Volume 2, Book 1. Commercial plant conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    The conceptual design of the 100-MW solar tower focus commercial power plant is described in detail. Sodium is pumped up to the top of a tall tower where the receiver is located. The sodium is heated in the receiver and then flows down the tower, through a pressure reducing device, and thence into a large, hot storage tank which is located at ground level and whose size is made to meet a specific thermal energy storage capacity requirement. From this tank, the sodium is pumped by a separate pump, through a system of sodium-to-water steam generators. The steam generator system consists of a separate superheater and reheater operating in parallel and an evaporator unit operating in series with the other two units. The sodium flowing from the evaporator unit is piped to a cold storage tank. From the cold storage tank, sodium is then pumped up to the tip of the tower to complete the cycle. The steam generated in the steam generators is fed to a conventional off-the-shelf, high-efficiency turbine. The steam loop operates in a conventional rankine cycle with the steam generators serving the same purpose as a conventional boiler and water being fed to the evaporator with conventional feedwater pumps. The pressure reducing device (a standard drag valve, for example) serves to mitigate the pressure caused by the static head of sodium and thus allows the large tanks to operate at ambient pressure conditions. (WHK)

  3. Central receiver solar thermal power system, Phase 1. CDRL Item 2. Pilot plant preliminary design report. Volume IV. Receiver subsystem. [10-MW Pilot Plant and 100-MW Commercial Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-11-01

    The conception, design, and testing of the receiver subsystem proposed by the McDonnell Douglas/Rocketdyne Receiver team for the DOE 10-MW Pilot Plant and the 100-MW Commercial Plant are described. The receiver subsystem consists of the receiver unit, the tower on which the receiver unit is mounted above the collector field, and the supporting control and instrumentation equipment. The plans for implementation of the Pilot Plant are given including the anticipated schedule and production plan (procurement, installation, checkout, and maintenance). Specifications for the performance, design, and test requirements for the Pilot Plant receiver subsystem are included. (WHK)

  4. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The overall, long term objective of the Solar Central Receiver Hybrid Power System is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumpton, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains appendices to the conceptual design and systems analysis studies gien in Volume II, Books 1 and 2. (WHK)

  5. Conceptual design of advanced central receiver power systems sodium-cooled receiver concept. Volume 1. Executive summary. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    The conceptual design of an advanced central receiver power system using liquid sodium as a heat transport medium has been completed by a team consisting of the Energy Systems Group (prime contractor), McDonnell Douglas, Stearns-Roger, The University of Houston, and Salt River Project. The purpose of this study was to determine the technical and economic advantages of this concept for commercial-scale power plants. This final report covers all tasks of the project. These tasks were as follows: (1) review and analysis of preliminary specification; (2) parametric analysis; (3) select commercial configuration; (4) commercial plant conceptual design; (5) assessment of commercial plant; (6) advanced central receiver power system development plan; (7) program plan; (8) reports and data; (9) program management; and (10) safety analysis. A programmatic overview of the accomplishments of this program is given. The 100-MW conceptual commercial plant, the 281-MW optimum plant, and the 10-MW pilot plant are described. (WHK)

  6. Central Receiver Solar Thermal Power System, Phase 1. CDRL Item 10. First quarterly technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1976-01-01

    The current definition of a 10-MWe pilot plant preliminary design base line is presented, as well as a summary of a 100-MWe commercial plant base line. The subsystems described for the plants include the collector, receiver, thermal storage, and electrical power generation. A master control concept employing a centralized computer is also described. The subsystem research experiment activities for the collector, receiver, and thermal storage subsystems are presented, including a summary of SRE test requirements, overall test scheduling, and status through the conceptual design review phase of the SRE effort.

  7. Central receiver solar thermal power system, Phase 1. CDRL item 2. Pilot plant preliminary design report. Volume VI. Electrical power generation and master control subsystems and balance of plant

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    The requirements, performance, and subsystem configuration for both the Commercial and Pilot Plant electrical power generation subsystems (EPGS) and balance of plants are presented. The EPGS for both the Commercial Plant and Pilot Plant make use of conventional, proven equipment consistent with good power plant design practices in order to minimize risk and maximize reliability. The basic EPGS cycle selected is a regenerative cycle that uses a single automatic admission, condensing, tandem-compound double-flow turbine. Specifications, performance data, drawings, and schematics are included. (WHK)

  8. Central receiver solar thermal power system, phase 1. Progress report for period ending December 31, 1975

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-04-01

    The program objective is the preliminary design of a 10 MWe pilot solar power plant supported by major subsystem experiments. Progress is reported on the following task elements: 10 MWe pilot plant; collector subsystem design and analysis; receiver subsystem requirements; receiver subsystem design; thermal storage subsystem; electrical power generation subsystem; and pilot plant architectural engineering and support. (WDM)

  9. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, Michael W [Pratt & Whitney Rocketdyne; Miner, Kris [Pratt & Whitney Rocketdyne

    2013-03-30

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to

  10. Combined cycle solar central receiver hybrid power system study. Final technical report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    This study develops the conceptual design for a commercial-scale (nominal 100 MWe) central receiver solar/fossil fuel hybrid power system with combined cycle energy conversion. A near-term, metallic heat pipe receiver and an advanced ceramic tube receiver hybrid system are defined through parametric and market potential analyses. Comparative evaluations of the cost of power generation, the fuel displacement potential, and the technological readiness of these two systems indicate that the near-term hybrid system has better potential for commercialization by 1990. Based on the assessment of the conceptual design, major cost and performance improvements are projected for the near-term system. Constraints preventing wide-spread use were not identified. Energy storage is not required for this system and analyses show no economic advantages with energy storage provisions. It is concluded that the solar hybrid system is a cost effective alternative to conventional gas turbines and combined cycle generating plants, and has potential for intermediate-load market penetration at 15% annual fuel escalation rate. Due to their flexibility, simple solar/nonsolar interfacing, and short startup cycles, these hybrid plants have significant operating advantages. Utility company comments suggest that hybrid power systems will precede stand-alone solar plants.

  11. Central receiver solar thermal power system, Phase 1. CRDL Item 2. Pilot plant preliminary design report. Volume III, Book 2. Collector subsystem

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    The methods and plans for the manufacture of the 10-MW collector heliostats and associated controls for the pilot plant are detailed. An in-depth description of the production, installation, and verification testing of heliostats for the pilot plant is presented. Specifications for the performance, design, and test requirements for the pilot plant collector subsystem are included. Also, a heliostat location summary report is given. (WHK)

  12. Design, fabrication, and test of a heliostat for a central receiver solar thermal power plant. Project technical report, May 1974--Sep 1975

    Energy Technology Data Exchange (ETDEWEB)

    Blackmon, J.B.

    1975-09-01

    A full-scale central pedestal mounted elevation/azimuth heliostat was designed, fabricated, and tested. The heliostat consisted of a flat reflective surface composed of two co-planar lights of back silvered (second surface) glass, each 3.7 m (12 ft) x 1.85 m (6 ft) x 6 mm (1/4 inch) bonded to a steel frame structural support. The structural support was mounted on a drive housing equipped with a linear actuator for control of the elevation (tilt) axis, and a harmonic drive for azimuth control. DC gear motors (1/30 hp) were used in both drive axes. A quadrant photosensor mounted on a separate pedestal and aligned along the target-mirror of sight provided error signals to an analogue circuit which performed the error signal transformations and provided properly apportioned steering commands to the DC motors on the elevation/azimuth movement. Tracking and beam dispersion characteristics were investigated at six typical positions in the field ranging from 300 to 3000 ft horizontally from a screen target suspended between two 360 ft high towers. (GRA)

  13. Exergy and Thermoeconomic Analyses of Central Receiver Concentrated Solar Plants Using Air as Heat Transfer Fluid

    Directory of Open Access Journals (Sweden)

    Claudia Toro

    2016-10-01

    Full Text Available The latest developments in solar technologies demonstrated that the solar central receiver configuration is the most promising application among concentrated solar power (CSP plants. In CSPs solar-heated air can be used as the working fluid in a Brayton thermal cycle and as the heat transfer fluid for a Rankine thermal cycle as an alternative to more traditional working fluids thereby reducing maintenance operations and providing the power section with a higher degree of flexibility To supply thermal needs when the solar source is unavailable, an auxiliary burner is requested. This configuration is adopted in the Julich CSP (J-CSP plant, operating in Germany and characterized by a nominal power of 1.5 MW, the heat transfer fluid (HTF is air which is heated in the solar tower and used to produce steam for the bottoming Rankine cycle. In this paper, the J-CSP plant with thermal energy storage has been compared with a hybrid CSP plant (H-CSP using air as the working fluid. Thermodynamic and economic performances of all the simulated plants have been evaluated by applying both exergy analysis and thermoeconomic analysis (TA to determine the yearly average operation at nominal conditions. The exergy destructions and structure as well as the exergoeconomic costs of products have been derived for all the components of the plants. Based on the obtained results, the thermoeconomic design evaluation and optimization of the plants has been performed, allowing for improvement of the thermodynamic and economic efficiency of the systems as well as decreasing the exergy and exergoeconomic cost of their products.

  14. Power generation plant integrating concentrated solar power receiver and pressurized heat exchanger

    Science.gov (United States)

    Sakadjian, Bartev B; Flynn, Thomas J; Hu, Shengteng; Velazquez-Vargas, Luis G; Maryamchik, Mikhail

    2016-10-04

    A power plant includes a solar receiver heating solid particles, a standpipe receiving solid particles from the solar receiver, a pressurized heat exchanger heating working fluid by heat transfer through direct contact with heated solid particles flowing out of the bottom of the standpipe, and a flow path for solid particles from the bottom of the standpipe into the pressurized heat exchanger that is sealed by a pressure P produced at the bottom of the standpipe by a column of heated solid particles of height H. The flow path may include a silo or surge tank comprising a pressure vessel connected to the bottom of the standpipe, and a non-mechanical valve. The power plant may further include a turbine driven by heated working fluid discharged from the pressurized heat exchanger, and a compressor driven by the turbine.

  15. Solar Pilot Plant, Phase I. Preliminary design report. Volume II, Book 2. Central receiver optical model users manual. CDRL item 2. [HELIAKI code

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-05-01

    HELIAKI is a FORTRAN computer program which simulates the optical/thermal performance of a central receiver solar thermal power plant for the dynamic conversion of solar-generated heat to electricity. The solar power plant which this program simulates consists of a field of individual sun tracking mirror units, or heliostats, redirecting sunlight into a cavity, called the receiver, mounted atop a tower. The program calculates the power retained by that cavity receiver at any point in time or the energy into the receiver over a year's time using a Monte Carlo ray trace technique to solve the multiple integral equations. An artist's concept of this plant is shown.

  16. 塔式太阳能电站聚光镜场的土地利用率研究%Study on ground coverage of heliostats field in central receiver solar power plant

    Institute of Scientific and Technical Information of China (English)

    丁婷婷; 祝雪妹

    2012-01-01

    Most conventional heliostats field consist of rectangular heliostats, which have regular arrangement in central receiver solar power plant. The maximum ground coverage possible of such heliostats field without colliding neighboring reflectors is 58%. In this paper, a regular and radial arrangement of heliostats field is presented, a ground coverage model of different shape reflectors is carried out, and calculates different ground coverage in different situations. The simulation results show that a maximum ground coverage will obtain when width -height ratio of rectangular reflectors and hexagonal reflectors meet necessary condition. With die shape of hexagonal reflectors ground coverage is up to 100%.%塔式太阳能热发电站的聚光镜场大多是由按一定规律排列的矩形定日镜组成,在相邻定日镜间无机械碰撞的情况下,聚光镜场的最大土地利用率仅为58%.文章提出了选用规则交错排列的聚光镜场布置方案,建立不同形状定日镜的土地利用模型,并计算出不同情况下的最大土地利用率.通过仿真得出,矩形定日镜和六边形定日镜在一定长宽比时可获得最大土地利用率,其中六边形定日镜的土地利用率最高,约为100%.

  17. A handbook for solar central receiver design

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, P.K.

    1986-12-01

    This Handbook describes central receiver technology for solar thermal power plants. It contains a description and assessment of the major components in a central receiver system configured for utility scale production of electricity using Rankine-cycle steam turbines. It also describes procedures to size and optimize a plant and discussed examples from recent system analyses. Information concerning site selection criteria, cost estimation, construction, and operation and maintenance is also included, which should enable readers to perform design analyses for specific applications.

  18. Solar central receiver hybrid power system, Phase I. Volume 2. Conceptual design. Final technical report, October 1978-August 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-09-01

    The objectives of this study were to develop a hybrid power system design that (1) produces minimum cost electric power, (2) minimizes the capital investment and operating cost, (3) permits capacity displacement, (4) and achieves utility acceptance for market penetration. We have met the first three of these objectives and therefore believe that the fourth, utility acceptance, will become a reality. These objectives have been met by utilizing the Martin Marietta concept that combines the alternate central receiver power system design and a high-temperature salt primary heat transfer fluid and thermal storage media system with a fossil-fired nonsolar energy source. Task 1 reviewed the requirements definition document and comments and recommendations were provided to DOE/San Francisco. Task 2 consisted of a market analysis to evaluate the potential market of solar hybrid power plants. Twenty-two utilities were selected within nine regions of the country. Both written and verbal correspondence was used to assess solar hybrid power plants with respect to the utilities' future requirements and plans. The parametric analysis of Task 3 evaluated a wide range of subsystem configurations and sizes. These analyses included subsystems from the solar standalone alternate central receiver power system using high-temperature molten salt and from fossil fuel nonsolar subsystems. Task 4, selection of the preferred commerical system configuration, utilized the parametric analyses developed in Task 3 to select system and subsystem configurations for the commercial plant design. Task 5 developed a conceptual design of the selected commercial plant configuration and assessed the related cost and performance. Task 6 assessed the economics and performance of the selected configuration as well as future potential improvements or limitations of the hybrid power plants.

  19. Thermodynamic Analysis of Beam down Solar Gas Turbine Power Plant equipped with Concentrating Receiver System

    Science.gov (United States)

    Azharuddin; Santarelli, Massimo

    2016-09-01

    Thermodynamic analysis of a closed cycle, solar powered Brayton gas turbine power plant with Concentrating Receiver system has been studied. A Brayton cycle is simpler than a Rankine cycle and has an advantage where the water is scarce. With the normal Brayton cycle a Concentrating Receiver System has been analysed which has a dependence on field density and optical system. This study presents a method of optimization of design parameter, such as the receiver working temperature and the heliostats density. This method aims at maximizing the overall efficiency of the three major subsystem that constitute the entire plant, namely, the heliostat field and the tower, the receiver and the power block. The results of the optimization process are shown and analysed.

  20. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume II, Book 1. Conceptual design, Sections 1 through 4

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume presents in detail the market analysis, parametric analysis, and the selection process for the preferred system. (WHK)

  1. Conceptual design of solar central-receiver hybrid power system: sodium-cooled-receiver concept. Volume I of II. Conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    A market analysis is reported consisting of estimates of overall market size derived from projections of electric power growth, examination of utility plans, and projections of potential regulatory action. Market share is projected by comparisons of the levelized costs of busbar power produced by hybrid coal solar units with costs of other electric power producers such as coal only, nuclear and solar only units. Parametric analyses of the major subsystems, consisting of the collector, receiver, storage, non-solar, electric power generation, and master control subsystems were conducted over a wide range of independent parameters in order to define subsystem operation and interfaces for use in the preferred system selection studies. The selection of the system, subsystems, and components of the 0.8 and 1.4 solar multiple sodium-cooled hybrid central receiver configurations were done. Technically feasible alternatives were compared on an economic basis. Detailed conceptual designs of the selected system concepts for the 0.8 and 1.4 solar multiple plants are presented. Cost estimates are also presented for both plants based on the conceptual designs. (LEW)

  2. Solar central receiver hybrid power system. Monthly technical progress report for the month of December 1978

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-01-17

    Levelized busbar energy costs for the sodium-cooled hybrid central receiver concept using both oil and coal as a fuel were developed as a function of the plant capacity factor and as a function of the solar multiple. The fuel escalation question was reviewed in detail on the basis of past historical data, and it was concluded that the lower escalation numbers that are provided in the requirements definition document appear to be more likely to represent the real situation. Subsystem-level trade studies were continued during this reporting period. A detailed investigation of the series/parallel arrangement of the sodium heater and solar receiver was conducted. The various performance, lifetime, and cost factors were determined for each arrangement for the receiver and nonsolar subsystems, respectively. Collector subsystem studies were continued. Revised cost algorithms that include levelized O and M costs for the heliostats were generated in order that they can be used in the field optimization. On the basis of the subsystem studies and the economic assessment work, a reference configuration was tentatively derived. This configuration does not require storage and uses a parallel arrangement of the receiver and the heater. At this time, a coal-fired heater seems to have a potential economic advantage under realistic assumptions for the escalation of coal relative to oil over the next decade or so.

  3. Improved high temperature solar absorbers for use in Concentrating Solar Power central receiver applications.

    Energy Technology Data Exchange (ETDEWEB)

    Stechel, Ellen Beth; Ambrosini, Andrea; Hall, Aaron Christopher; Lambert, Timothy L.; Staiger, Chad Lynn; Bencomo, Marlene

    2010-09-01

    Concentrating solar power (CSP) systems use solar absorbers to convert the heat from sunlight to electric power. Increased operating temperatures are necessary to lower the cost of solar-generated electricity by improving efficiencies and reducing thermal energy storage costs. Durable new materials are needed to cope with operating temperatures >600 C. The current coating technology (Pyromark High Temperature paint) has a solar absorptance in excess of 0.95 but a thermal emittance greater than 0.8, which results in large thermal losses at high temperatures. In addition, because solar receivers operate in air, these coatings have long term stability issues that add to the operating costs of CSP facilities. Ideal absorbers must have high solar absorptance (>0.95) and low thermal emittance (<0.05) in the IR region, be stable in air, and be low-cost and readily manufacturable. We propose to utilize solution-based synthesis techniques to prepare intrinsic absorbers for use in central receiver applications.

  4. Thermal buffering of receivers for parabolic dish solar thermal power plants

    Science.gov (United States)

    Manvi, R.; Fujita, T.; Gajanana, B. C.; Marcus, C. J.

    1980-01-01

    A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.

  5. Layouts of trigeneration plants for centralized power supply

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Il'ina, I. P.; Rozhnatovskii, V. D.; Burmakina, A. V.

    2016-06-01

    One of the possible and, under certain conditions, sufficiently effective methods for reducing consumption of fuel and energy resources is the development of plants for combined generation of different kinds of energy. In the power industry of Russia, the facilities have become widespread in which the cogeneration technology, i.e., simultaneous generation of electric energy and heat, is implemented. Such facilities can use different plants, viz., gas- and steam-turbine plants and gas-reciprocating units. Cogeneration power supply can be further developed by simultaneously supplying the users not only with electricity and heat but also with cold. Such a technology is referred to as trigeneration. To produce electricity and heat, trigeneration plants can use the same facilities that are used in cogeneration, namely, gas-turbine plants, steam-turbine plants, and gas-reciprocating units. Cold can be produced in trigeneration plants using thermotransformers of various kinds, such as vaporcompression thermotransformers, air thermotransformers, and absorption thermotransformers, that operate as chilling machines. The thermotransformers can also be used in the trigeneration plants to generate heat. The main advantage of trigeneration plants based on gas-turbine plants or gas-reciprocating units over cogeneration plants is the increased thermodynamic power supply efficiency owing to utilization of the waste-gas heat not only in winter but also in summer. In the steam-turbine-based trigeneration plants equipped with absorption thermotransformers, the enhancement of the thermodynamic power supply efficiency is determined by the increase in the heat extraction load during the nonheating season. The article presents calculated results that demonstrate higher thermodynamic efficiency of a gas-turbine-based plant with an absorption thermotransformer that operates in the trigeneration mode compared with a cogeneration gas-turbine plant. The structural arrangements of trigeneration

  6. Dosimetry in nuclear power plants; Dosimetria en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lastra B, J. A. [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2008-12-15

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  7. User's manual for DELSOL2: a computer code for calculating the optical performance and optimal system design for solar-thermal central-receiver plants

    Energy Technology Data Exchange (ETDEWEB)

    Dellin, T.A.; Fish, M.J.; Yang, C.L.

    1981-08-01

    DELSOL2 is a revised and substantially extended version of the DELSOL computer program for calculating collector field performance and layout, and optimal system design for solar thermal central receiver plants. The code consists of a detailed model of the optical performance, a simpler model of the non-optical performance, an algorithm for field layout, and a searching algorithm to find the best system design. The latter two features are coupled to a cost model of central receiver components and an economic model for calculating energy costs. The code can handle flat, focused and/or canted heliostats, and external cylindrical, multi-aperture cavity, and flat plate receivers. The program optimizes the tower height, receiver size, field layout, heliostat spacings, and tower position at user specified power levels subject to flux limits on the receiver and land constraints for field layout. The advantages of speed and accuracy characteristic of Version I are maintained in DELSOL2.

  8. Conceptual design of advanced central receiver power system. Phase I. Executive summary and final report

    Energy Technology Data Exchange (ETDEWEB)

    Tracey, T. R.

    1978-09-01

    The designed system has a net electrical output of 300 MWe and has sufficient heliostats and storage capacity to provide full load operation 24 hours per day at summer solstice. The system consists of nine heliostat fields with 7711 heliostats in each. The heliostats track the sun and direct the solar energy incident on them to one of four cavity apertures located at the top of a 155-meter (510 ft) tower. Inside the cavity the flux is absorbed on panels. The panels are cooled by molten salt that enters the receiver at 561/sup 0/K (550/sup 0/K) and leaves the receiver at 838/sup 0/K (1050/sup 0/F). Salt flowrate is controlled to maintain a constant salt exit temperature at the receiver outlet. The hot salt is pumped to the steam generator and/or the storage system. Hot salt pumped to the storage system is stored for later use by the steam generator. The hot salt pumped to the steam generating system is used by the steam generator to heat boiler feedwater and make 783/sup 0/K (950/sup 0/K), 16.5 MPa (2400 psig) superheated steam for the steam turbine/generator. During the process the hot salt is cooled to 561/sup 0/K (550/sup 0/K). The cold salt is pumped to the bottom of the thermal storage tank and/or back to the receivers. During periods when solar insolation is insufficient for rated operation, energy is extracted from the storage system and used to supply heat to the steam generator. The master control system is computerized and provides operator over-rides that serve as overall plant control. It also provides data display and storage.

  9. Central receiver solar thermal power system, Phase 1. CDRL Item 2. Pilot plant preliminary design report. Volume V. Thermal storage subsystem. [Sensible heat storage using Caloria HT43 and mixture of gravel and sand

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    The proposed 100-MWe Commercial Plant Thermal Storage System (TSS) employs sensible heat storage using dual liquid and solid media for the heat storage in each of four tanks, with the thermocline principle applied to provide high-temperature, extractable energy independent of the total energy stored. The 10-MW Pilot Plant employs a similar system except uses only a single tank. The high-temperature organic fluid Caloria HT43 and a rock mixture of river gravel and No. 6 silica sand were selected for heat storage in both systems. The system design, installation, performance testing, safety characteristics, and specifications are described in detail. (WHK)

  10. Central receiver solar thermal power system, phase 1. Quarterly progress report (final) for period ending June 30, 1976

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-10-01

    During this report period, the major program activities were aimed toward the fabrication of the three major research experiments and continued evaluation of the Pilot Plant performance and operating modes. The detail designs were completed early in this period. Effort was continued in the evaluation of Pilot Plant start transients. Both warm and hot starts from thermal storage were evaluated as was a cold start from the Receiver. In the Collector Subsystem Experiment the heliostat structures and drive mechanisms were completed and delivered. The detail design of the 5 MW Receiver Experiment was completed at Foster Wheeler. In the Thermal Storage Subsystem the detail design of the experiment was completed early in the period. A final selection of the heat transport media was made with Hitec selected as the molten salt and Caloria HT-43 selected as the hydrocarbon oil. During this period Bechtel continued its efforts in the optimization of the Electrical Power Generation Subsystem. Work was also continued on the completion of data that will be used in the Electrical Power Generation Subsystem analytical model being prepared by Martin as a part of the overall Pilot Plant Simulation Model. (WDM)

  11. Central-receiver solar-thermal power system. Collector subsystem research experiments detail design report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-02-24

    The detail design (DD) of research experiment hardware for the collector subsystem (heliostats) to support the 10 MW/sub e/ Pilot Plant preliminary design (PD) is presented. Additionally, test plans for assembly, integration, and array tests are presented, along with results of completed component/material tests. Research experiment DD and tests described were planned to provide design verification and supporting data, with hardware which either duplicates, or closely simulates the Pilot Plant PD baseline. (WHK)

  12. Remote and Centralized Monitoring of PV Power Plants

    DEFF Research Database (Denmark)

    Kopacz, Csaba; Spataru, Sergiu; Sera, Dezso

    2014-01-01

    the inverters within each PV plant. The monitoring software stores the PV measurements in a data warehouse optimized for managing and data mining large amounts of data, from where it can be later visualized, analyzed and exported. By combining PV production measurements data with I-V curve measurements...

  13. Integral power evaluation in fossil fuel power plants; Evaluacion energetica integral en unidades de centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa I, Luis R; Sanchez H, Laura E; Rodriguez M, Jose H [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Nebradt G, Jesus [Unidad de Investigacion y Desarrollo de la Subdireccion de Generacion de la Comision Federal de Electricidad, (Mexico)

    2006-07-01

    In this occasion, a methodology is presented that carries out an integral energy evaluation of fossil fuel power plants units (FFPPU) with the purpose of determining the root of the significant decrements of power produced soon after the annual maintenance service. This proposal, besides identifying the origin of the energy efficiency problems, offers information about the contributions of each one of the involved equipment in the total decrement of the unit. With this methodology, the maintenance focuses in the equipment that contributes to the greater energy loss. This document presents such methodology along with its application in a real case, results and necessary remedial actions, demonstrating that its application offers bases for the investment in corrective measures. [Spanish] En esta ocasion se presenta una metodologia que efectua una evaluacion energetica integral de las unidades de centrales termoelectricas (UCT) con el fin de determinar la raiz de los decrementos de potencia significativos producidos luego del servicio anual de mantenimiento. Dicha propuesta, ademas de identificar el origen de los problemas de eficiencia energetica, brinda informacion acerca de las aportaciones de cada uno de los equipos involucrados al decremento total de la unidad. Con esta metodologia, el mantenimiento se enfoca a los equipos que contribuyen a la mayor perdida de potencia. Este documento exhibe tal metodologia junto con su aplicacion en un caso real, resultados y las acciones correctivas necesarias, demostrando que su aplicacion ofrece bases para una inversion futura en medidas correctivas.

  14. Transient Simulation Of A Solar-Hybrid Tower Power Plant With Open Volumetric Receiver At The Location Barstow

    OpenAIRE

    2013-01-01

    In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine’s flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well a...

  15. Transient simulation of molten salt central receiver

    Science.gov (United States)

    Doupis, Dimitri; Wang, Chuan; Carcorze-Soto, Jorge; Chen, Yen-Ming; Maggi, Andrea; Losito, Matteo; Clark, Michael

    2016-05-01

    Alstom is developing concentrated solar power (CSP) utilizing 60/40wt% NaNO3-KNO3 molten salt as the working fluid in a tower receiver for the global renewable energy market. In the CSP power generation cycle, receivers undergo a daily cyclic operation due to the transient nature of solar energy. Development of robust and efficient start-up and shut-down procedures is critical to avoiding component failures due to mechanical fatigue resulting from thermal transients, thus maintaining the performance and availability of the CSP plant. The Molten Salt Central Receiver (MSCR) is subject to thermal transients during normal daily operation, a cycle that includes warmup, filling, operation, draining, and shutdown. This paper describes a study to leverage dynamic simulation and finite element analysis (FEA) in development of start-up, shutdown, and transient operation concepts for the MSCR. The results of the FEA also verify the robustness of the MSCR design to the thermal transients anticipated during the operation of the plant.

  16. Central station applications planning activities and supporting studies. [application of photovoltaic technology to power generation plants

    Science.gov (United States)

    Leonard, S. L.; Siegel, B.

    1980-01-01

    The application of photovoltaic technology in central station (utility) power generation plants is considered. A program of data collection and analysis designed to provide additional information about the subset of the utility market that was identified as the initial target for photovoltaic penetration, the oil-dependent utilities (especially muncipals) of the U.S. Sunbelt, is described along with a series of interviews designed to ascertain utility industry opinions about the National Photovoltaic Program as it relates to central station applications.

  17. Receiver subsystem analysis report (RADL Item 4-1). 10-MWe Solar Thermal Central-Receiver Pilot Plant: solar-facilities design integration

    Energy Technology Data Exchange (ETDEWEB)

    1982-04-01

    The results are presented of those thermal hydraulic, structural, and stress analyses required to demonstrate that the Receiver design for the Barstow Solar Pilot Plant will satisfy the general design and performance requirements during the plant's design life. Recommendations resulting from those analyses and supporting test programs are presented regarding operation of the receiver. The analyses are limited to receiver subsystem major structural parts (primary tower, receiver unit core support structure), pressure parts (absorber panels, feedwater, condensate and steam piping/components, flash tank, and steam mainfold) and shielding. (LEW)

  18. Software/firmware design specification for 10-MWe solar-thermal central-receiver pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Ladewig, T.D.

    1981-03-01

    The software and firmware employed for the operation of the Barstow Solar Pilot Plant are completely described. The systems allow operator control of up to 2048 heliostats, and include the capability of operator-commanded control, graphic displays, status displays, alarm generation, system redundancy, and interfaces to the Operational Control System, the Data Acquisition System, and the Beam Characterization System. The requirements are decomposed into eleven software modules for execution in the Heliostat Array Controller computer, one firmware module for execution in the Heliostat Field Controller microprocessor, and one firmware module for execution in the Heliostat Controller microprocessor. The design of the modules to satisfy requirements, the interfaces between the computers, the software system structure, and the computers in which the software and firmware will execute are detailed. The testing sequence for validation of the software/firmware is described. (LEW)

  19. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  20. Ozone risk assessment for plants: Central role of metabolism-dependent changes in reducing power

    Energy Technology Data Exchange (ETDEWEB)

    Dizengremel, Pierre [Faculte des Sciences et Techniques, UMR1137 Ecologie et Ecophysiologie Forestieres, Nancy-Universite, BP239, F-54506 Vandoeuvre-les-Nancy Cedex (France)], E-mail: pierre.dizengremel@scbiol.uhp-nancy.fr; Le Thiec, Didier [INRA, UMR1137 Ecologie et Ecophysiologie Forestieres, Centre INRA de Nancy, F-54280 Champenoux (France)], E-mail: le_thiec@nancy.inra.fr; Bagard, Matthieu [Faculte des Sciences et Techniques, UMR1137 Ecologie et Ecophysiologie Forestieres, Nancy-Universite, BP239, F-54506 Vandoeuvre-les-Nancy Cedex (France)], E-mail: matthieu.bagard@scbiol.uhp-nancy.fr; Jolivet, Yves [Faculte des Sciences et Techniques, UMR1137 Ecologie et Ecophysiologie Forestieres, Nancy-Universite, BP239, F-54506 Vandoeuvre-les-Nancy Cedex (France)], E-mail: yves.jolivet@scbiol.uhp-nancy.fr

    2008-11-15

    The combination of stomatal-dependent ozone flux and total ascorbate level is currently presented as a correct indicator for determining the degree of sensitivity of plants to ozone. However, the large changes in carbon metabolism could play a central role in the strategy of the foliar cells in response to chronic ozone exposure, participating in the supply of reducing power and carbon skeletons for repair and detoxification, and modifying the stomatal mode of functioning. To reinforce the accuracy of the definition of the threshold for ozone risk assessment, it is proposed to also consider the redox pool (NAD(P)H), the ratio between carboxylases and the water use efficiency as indicators of the differential ozone tolerance of plants. - We propose reducing power, Rubisco/PEPc ratio and water use efficiency as additional indicators in ozone risk assessment for plants.

  1. Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey

    OpenAIRE

    Raad Kadhim Al-Dualimi; Mehmet Sait Söylemez

    2016-01-01

    A prior study on the performance of high-efficient models for a heliostat field and solar receiver at various candidate locations (e.g., certain regions in the south of Turkey) helped determine suitable locations for installing solar tower power plant units. This study considered the fact that solar tower power plants are affected by the working conditions of a particular site, which helps realize the highest performance of the solar power tower plant. An optimized heliostat field consisting ...

  2. Computer Security for Commercial Nuclear Power Plants - Literature Review for Korea Hydro Nuclear Power Central Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Felicia Angelica [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Security Systems Analysis Dept.; Waymire, Russell L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Security Systems Analysis Dept.

    2013-10-01

    Sandia National Laboratories (SNL) is providing training and consultation activities on security planning and design for the Korea Hydro and Nuclear Power Central Research Institute (KHNPCRI). As part of this effort, SNL performed a literature review on computer security requirements, guidance and best practices that are applicable to an advanced nuclear power plant. This report documents the review of reports generated by SNL and other organizations [U.S. Nuclear Regulatory Commission, Nuclear Energy Institute, and International Atomic Energy Agency] related to protection of information technology resources, primarily digital controls and computer resources and their data networks. Copies of the key documents have also been provided to KHNP-CRI.

  3. Elecnuc. Nuclear power plants in the world; Elecnuc. Les centrales nucleaires dans le monde

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This 2003 version of Elecnuc contents information, data and charts on the nuclear power plants in the world and general information on the national perspectives concerning the electric power industry. The following topics are presented: 2002 highlights; characteristics of main reactor types and on order; map of the French nuclear power plants; the worldwide status of nuclear power plants on 2002/12/3; units distributed by countries; nuclear power plants connected to the Grid by reactor type groups; nuclear power plants under construction; capacity of the nuclear power plants on the grid; first electric generations supplied by a nuclear unit; electrical generation from nuclear plants by country at the end 2002; performance indicator of french PWR units; trends of the generation indicator worldwide from 1960 to 2002; 2002 cumulative Load Factor by owners; nuclear power plants connected to the grid by countries; status of license renewal applications in Usa; nuclear power plants under construction; Shutdown nuclear power plants; exported nuclear power plants by type; exported nuclear power plants by countries; nuclear power plants under construction or order; steam generator replacements; recycling of Plutonium in LWR; projects of MOX fuel use in reactors; electricity needs of Germany, Belgium, Spain, Finland, United Kingdom; electricity indicators of the five countries. (A.L.B.)

  4. Zero-power receiver

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert W.

    2016-10-04

    An unpowered signal receiver and a method for signal reception detects and responds to very weak signals using pyroelectric devices as impedance transformers and/or demodulators. In some embodiments, surface acoustic wave devices (SAW) are also used. Illustrative embodiments include satellite and long distance terrestrial communications applications.

  5. Elecnuc. Nuclear power plants in the world; Elecnuc. Les centrales nucleaires dans le monde

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This small booklet summarizes in tables all data relative to the nuclear power plants worldwide. These data come from the IAEA's PRIS and AREVA-CEA's GAIA databases. The following aspects are reviewed: 2007 highlights; Main characteristics of reactor types; Map of the French nuclear power plants on 2007/01/01; Worldwide status of nuclear power plants (12/31/2007); Units distributed by countries; Nuclear power plants connected to the Grid- by reactor type groups; Nuclear power plants under construction on 2007; Evolution of nuclear power plants capacities connected to the grid; First electric generations supplied by a nuclear unit in each country; Electrical generation from nuclear power plants by country at the end 2007; Performance indicator of French PWR units; Evolution of the generation indicators worldwide by type; Nuclear operator ranking according to their installed capacity; Units connected to the grid by countries at 12/31/2007; Status of licence renewal applications in USA; Nuclear power plants under construction at 12/31/2007; Shutdown reactors; Exported nuclear capacity in net MWe; Exported and national nuclear capacity connected to the grid; Exported nuclear power plants under construction; Exported and national nuclear capacity under construction; Nuclear power plants ordered at 12/31/2007; Long term shutdown units at 12/31/2007; COL (combined licences) applications in the USA; Recycling of Plutonium in reactors and experiences; Mox licence plants projects; Appendix - historical development; Meaning of the used acronyms; Glossary.

  6. A 200kW central receiver CPV system

    Energy Technology Data Exchange (ETDEWEB)

    Lasich, John, E-mail: jbl@raygen.com; Thomas, Ian, E-mail: ithomas@raygen.com; Hertaeg, Wolfgang; Shirley, David; Faragher, Neil; Erenstrom, Neil; Carter, Sam; Cox, Brian; Zuo, Xinyi [Raygen Resources Pty. Ltd., 15 King Street, Blackburn, Victoria, 3130 (Australia)

    2015-09-28

    Raygen Resources has recently completed a Central Receiver CPV (CSPV) pilot plant in Central Victoria, Australia. The system is under final commissioning and initial operation is expected in late April 2015. The pilot demonstrates a full scale CSPV repeatable unit in a form that is representative of a commercial product and provides a test bed to prove out performance and reliability of the CSPV technology. Extensive testing of the system key components: dense array module, wireless solar powered heliostat and control system has been performed in the laboratory and on sun. Results from this key component testing are presented herein.

  7. A 200kW central receiver CPV system

    Science.gov (United States)

    Lasich, John; Thomas, Ian; Hertaeg, Wolfgang; Shirley, David; Faragher, Neil; Erenstrom, Neil; Carter, Sam; Cox, Brian; Zuo, Xinyi

    2015-09-01

    Raygen Resources has recently completed a Central Receiver CPV (CSPV) pilot plant in Central Victoria, Australia. The system is under final commissioning and initial operation is expected in late April 2015. The pilot demonstrates a full scale CSPV repeatable unit in a form that is representative of a commercial product and provides a test bed to prove out performance and reliability of the CSPV technology. Extensive testing of the system key components: dense array module, wireless solar powered heliostat and control system has been performed in the laboratory and on sun. Results from this key component testing are presented herein.

  8. Boiling water reactor in a prestressed reinforced concrete vessel for an atomic central heating-and-power plant

    Energy Technology Data Exchange (ETDEWEB)

    Tokarev, Yu.I.; Sokolov, I.N.; Skvortsov, S.A.; Sidorov, A.M.; Krauze, L.V.

    1978-04-01

    The possibility of using a boiling water reactor in a prestressed reinforced concrete vessel for an atomic central heating-and-power plant (CHPP) was considered, with design features of the reactor intended for a two-purpose plant. A prestressed reinforced concrete vessel and integral arrangement of the primary circuit ensured reliability of the atomic CHPP using various CHPP flowsheets.

  9. Puertollano IGCC Power Plant; Central de Gasificacion Integrada en Ciclo Combinado de Puertollano

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The Puertollano IGCC Power Plant, rated 335 MW and located in Puertollano, Ciudad Real, in the central area of Spain, is a project led by ELCOGAS, a company incorporated by the European utilities ENDESA, ELECTRICITE DE FRANCE, IBERDROLA HIDROCANTABRICO ELECTRICIDADE DE PURTUGAL, ENEL and NATIONAL POWER and the technology and equipment suppliers SIEMENS, KRUPP UHDE and BABCOCK WILCOX ESPANOLA. IGCC technology is based in a process of coal gasification to obtain a clean combustion synthetic gas, integrated with a combined cycle, agas and steam, electricity-generating unit. The energy efficiency which is aimed to achieve at the Plant is 46% in ISO conditions. The Gasification unit uses the process of pressurised entrained flow for coal gasification. The gas is produced by the reaction of coal with oxygen at high temperatures, of up to 1600 degree centigree. This process is capable of gasifying a wide variety of types and qualities of coal for the production of a synthetic fuel gas. In the case of Puertollano, the raw fuel is a 50% mixture by weight of local coal and petroleum coke. The oxygen needed in the process and the nitrogen used for covering the fuel is generated in the Air Separation. The Gas Cleaning and Sulphur Recovery Unit clean the gases from contaminants and solid particles before to send them to the Gas Turbine. The clean gas is burnt in gas turbine of the Combined Cycle Plant, producing electricity. The exhaust gases feed a heat recovery steam generator, which produces steam used to generate additional electricity in a conventional steam turbine. The gas turbine is capable of operating both with synthetic gas and with natural gas, allowing operation flexibility. The net output of the plant up to December 1999 was 3.061 GWh, from them 344 GWh were produced with synthetic gas. This project has an important technological value, being the first power plant which uses coal gasification to feed a combined cycle in Spain and being also the biggest power plant

  10. Elecnuc. Nuclear power plants in the world; Elecnuc. Les centrales nucleaires dans le monde

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This small booklet summarizes in tables all the numerical data relative to the nuclear power plants worldwide. These data come from the French CEA/DSE/SEE Elecnuc database. The following aspects are reviewed: 1999 highlights; main characteristics of the reactor types in operation, under construction or on order; map of the French nuclear power plants; worldwide status of nuclear power plants at the end of 1999; nuclear power plants in operation, under construction and on order; capacity of nuclear power plants in operation; net and gross capacity of nuclear power plants on the grid and in commercial operation; grid connection forecasts; world electric power market; electronuclear owners and share holders in EU, capacity and load factor; first power generation of nuclear origin per country, achieved or expected; performance indicator of PWR units in France; worldwide trend of the power generation indicator; 1999 gross load factor by operator; nuclear power plants in operation, under construction, on order, planned, cancelled, shutdown, and exported; planning of steam generators replacement; MOX fuel program for plutonium recycling. (J.S.)

  11. Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey

    Directory of Open Access Journals (Sweden)

    Raad Kadhim Al-Dualimi

    2016-08-01

    Full Text Available A prior study on the performance of high-efficient models for a heliostat field and solar receiver at various candidate locations (e.g., certain regions in the south of Turkey helped determine suitable locations for installing solar tower power plant units. This study considered the fact that solar tower power plants are affected by the working conditions of a particular site, which helps realize the highest performance of the solar power tower plant. An optimized heliostat field consisting of 2650 SENER heliostats and a model of a solar receiver based on the data obtained using Gemasolar in Seville, Spain, was used as a reference in this work. Each heliostat position is specified using an optimization algorithm that refines previously proposed models, and two parameters are added to this model to further optimize the heliostat layout. Then, a sample analytical thermal model is used for predicting the radiative and convective heat losses from the receiver system. Article History: Received March 13rd 2016; Received in revised form Jun 22nd 2016; Accepted July 3rd 2016; Available onlineHow to Cite This Article: Ra'ad, K, M, A. and Mehmet, S, S. (2016, Evaluating the potential energy of a heliostat field and solar receiver of solar tower power plants in the southern region of Turkey. Int. Journal of Renewable Energy Development, 5(2, 151-161, http://dx.doi.org/10.14710/ijred.5.2.151-161

  12. Working in a virtual power plant; Travailler dans une centrale virtuelle

    Energy Technology Data Exchange (ETDEWEB)

    Thibault, G.; Smadja, S

    1999-07-01

    Graphical simulations on computer providing a virtual and reversible experience can now be used for maintenance in nuclear power plants allowing operations to be tested and tools to be optimised. Eventually, operatives will be trained to work in virtual nuclear power plants in complete safety. (authors)

  13. CO2 capture processes in power plants - Le captage du CO2 dans les centrales thermiques

    CERN Document Server

    Bouallou, Chakib

    2010-01-01

    This review is devoted to assess and compare various processes aiming at recover CO2 from power plants fed with natural gas (NGCC) and pulverized coal (PC). These processes are post combustion CO2 capture using chemical solvents, natural gas reforming for pre-combustion capture and oxy-fuel combustion with cryogenic recovery of CO2. These processes were evaluated to give some clues for choosing the best option for each type of power plant. The comparison of these various concepts suggests that, in the short and medium term, chemical absorption is the most interesting process for NGCC power plants. For CP power plants, oxy-combustion can be a very interesting option, as well as post-combustion capture by chemical solvents.

  14. 2010 Pacific Gas and Electric Diablo Canyon Power Plant (DCPP): Diablo Canyon, CA Central Coast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Diablo Canyon Power Plant (DCPP) LiDAR and Imagery datasets are comprised of three separate LiDAR surveys: Diablo Canyon (2010), Diablo Canyon (2010), and San...

  15. 2011 Pacific Gas and Electric Diablo Canyon Power Plant (DCPP): Los Osos, CA Central Coast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Diablo Canyon Power Plant (DCPP) LiDAR and Imagery datasets are comprised of three separate LiDAR surveys: Diablo Canyon (2010), Los Osos (2011), and San Simeon...

  16. 2013 Pacific Gas and Electric Diablo Canyon Power Plant (DCPP): San Simeon, CA Central Coast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Diablo Canyon Power Plant (DCPP) LiDAR and Imagery datasets are comprised of three separate LiDAR surveys: Diablo Canyon (2010), Los Osos (2011), and San Simeon...

  17. Nuclear power plants making a comeback in Japan; El retorno de la centrales nucleares en Japon

    Energy Technology Data Exchange (ETDEWEB)

    Torralbo, J. R.

    2016-08-01

    We reproduce in this magazine the interesting article published by the president of the SNE in issue 46 of Cuadernos de Energia in October 2015, which describes the events that have taken place since the March 11, 2011 earthquake in Japan, the largest in its history, and the subsequent tsunami, which affected the Fukushima power plant, as well as the measures implemented since then and how some of this country nuclear power plants are being started up again. (Author)

  18. Mathematical Modeling of a developed Central Receiver Based on Evacuated Solar Tubes

    Directory of Open Access Journals (Sweden)

    Ali Basil. H.

    2016-01-01

    Full Text Available Solar central receiver plays a considerable role in the plant output power; it is one of the most important synthesis in the solar power tower plants. Its performance directly affects the efficiency of the entire solar power generation system. In this study, a new designed receiver model based on evacuated solar tube was proposed, and the dynamic characteristics of the developed receiver were investigated. In order to optimise and evaluate the dynamic characteristics of solar power plant components, the model investigates the solar radiation heat conversion process through the developed receiver, where the energy and mass conservation equations are used to determine the working fluid temperature and state through the receiver parts, beside the calculation and analysis of the thermal losses.

  19. Quality Assurance in Nuclear Power Plants; La garantia de calidad en la Centrales Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Zamarron Casinello, J. M. (CC.AA. Almaraz-Trillo); Gasca Pinilla, R. (Asociacion Nuclear Asco-Vandellos II); Sala Candela, A. (IBERDROLA); Valle Pena (NUCLENOR); Ruiz Rodriguez, C. (UNION FENOSA)

    2000-07-01

    In 1970, 10CFR50 Appendix B. Quality Assurance Criteria for Nuclear Power Plants & Fuel Reprocessing Plants, was approved in USA. This is based on 18 criteria and requires American nuclear power plants to establish as quickly as possible a Quality Assurance Program (QAP) specifying how to comply with the criteria contained in this Appendix. The Ministry of Industry required that this standard be observed in Spanish plants. In The first-generation plants (Jose Cabrera, Santa Maria de Garona and Vandellos 1), which were built before this new standard was developed, the concept of Quality Assurance has only been applied to the operating phase, whereas in second-generation plants (Almaraz, Asco3 and Cofrentes) and third-generation plants (Vandellos 2 and Trillo), the concept was applied from the very beginning of the project: design phases, construction and finally plant operation. In 1979, the IAEA publihed practical code 50-C-QA as an international reference document. It contains 13 criteria that coincide with and complement those established in Appendex B of 10CFR50. As a result, the nuclear power plants in all neighboring countries will be enforcing similar Quality Assurance criteria. (Author)

  20. The IRSN publishes an assessment of doses received in Japan by external irradiation due to radioactive deposits caused by the Fukushima-Daiichi power plant accident; L'IRSN publie une estimation des doses recues au Japon par irradiation externe due aux depots radioactifs provoques par l'accident de la centrale de Fukushima-Daiichi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    This document first describes how dry and wet radioactive deposits are formed. It also indicates their main components: iodine 131 and 132, caesium 134, 136 and 137, tellurium 132, and barium 140. It describes the different exposure ways due to radioactive deposits in the environment. A map indicates dose level assessments few tens of kilometres around the Fukushima power plant. A brief comment of this map is proposed

  1. Ground acceleration in a nuclear power plant; Aceleracion del suelo en una central nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Pena G, P.; Balcazar, M.; Vega R, E., E-mail: pablo.pena@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    A methodology that adopts the recommendations of international organizations for determining the ground acceleration at a nuclear power plant is outlined. Systematic presented here emphasizes the type of geological, geophysical and geotechnical studies in different areas of influence, culminating in assessments of Design Basis earthquake and the earthquake Operating Base. The methodology indicates that in regional areas where the site of the nuclear power plant is located, failures are identified in geological structures, and seismic histories of the region are documented. In the area of detail geophysical tools to generate effects to determine subsurface propagation velocities and spectra of the induced seismic waves are used. The mechanical analysis of drill cores allows estimating the efforts that generate and earthquake postulate. Studies show that the magnitude of the Fukushima earthquake, did not affect the integrity of nuclear power plants due to the rocky settlement found. (Author)

  2. 10-MWe solar-thermal central-receiver pilot plant: collector subsystem foundation construction. Revision No. 1

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-18

    Bid documents are provided for the construction of the collector subsystem foundation of the Barstow Solar Pilot Plant, including invitation to bid, bid form, representations and certifications, construction contract, and labor standards provisions of the Davis-Bacon Act. Instructions to bidders, general provisions and general conditions are included. Technical specifications are provided for the construction. (LEW)

  3. Life management plants at nuclear power plants PWR; Planes de gestion de vida en centrales nucleares PWR

    Energy Technology Data Exchange (ETDEWEB)

    Esteban, G.

    2014-10-01

    Since in 2009 the CSN published the Safety Instruction IS-22 (1) which established the regulatory framework the Spanish nuclear power plants must meet in regard to Life Management, most of Spanish nuclear plants began a process of convergence of their Life Management Plants to practice 10 CFR 54 (2), which is the current standard of Spanish nuclear industry for Ageing Management, either during the design lifetime of the plant, as well as for Long-Term Operation. This article describe how Life Management Plans are being implemented in Spanish PWR NPP. (Author)

  4. Atmospheric pollution in thermal power plants; Contaminacion atmosferica en centrales termicas convencionales

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre Diaz, A.

    1997-04-01

    The author presents the atmospheric pollution by fossil-fuel power plants. The state of the art is developed in 4 chapters: Legislation, Sulfur dioxide: reduction of SO{sub 2}, nitrogen oxides: reduction of emissions, particulates: reduction of particulates and new technologies. (Author)

  5. Refueling outage services in Spanish Nuclear Power Plants; Servicios en recargas de centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Landete, J. L.; Soto, M.; Nunuez, A.

    2007-07-01

    DOMINGUIS Group, through its 75 years of business development, has positioned as the Spanish leader Group in Services for the Nuclear Energy and Petrochemical Sectors. In this article, we present the most significant services summary that, through the companies that constitute DOMINGUIS Group, we have developed in Refueling Outage in Spanish Nuclear Power Plants. (Author)

  6. Solar central receiver heliostat reflector assembly

    Science.gov (United States)

    Horton, Richard H.; Zdeb, John J.

    1980-01-01

    A heliostat reflector assembly for a solar central receiver system comprises a light-weight, readily assemblable frame which supports a sheet of stretchable reflective material and includes mechanism for selectively applying tension to and positioning the sheet to stretch it to optical flatness. The frame is mounted on and supported by a pipe pedestal assembly that, in turn, is installed in the ground. The frame is controllably driven in a predetermined way by a light-weight drive system so as to be angularly adjustable in both elevation and azimuth to track the sun and efficiently continuously reflect the sun's rays to a focal zone, i.e. central receiver, which forms part of a solar energy utilization system, such as a solar energy fueled electrical power generation system. The frame may include a built-in system for testing for optical flatness of the reflector. The preferable geometric configuration of the reflector is octagonal; however, it may be other shapes, such as hexagonal, pentagonal or square. Several different embodiments of means for tensioning and positioning the reflector to achieve optical flatness are disclosed. The reflector assembly is based on the stretch frame concept which provides an extremely light-weight, simple, low-cost reflector assembly that may be driven for positioning and tracking by a light-weight, inexpensive drive system.

  7. Radiological protection in nuclear power plants; La proteccion radiologica en las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Zorrilla R, S. [CFE. Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2008-12-15

    This presentation sharing experiences which correspond to the nuclear power plant of Laguna Verde. This nuclear power plant is located at level 2 of four possible, in the classification performance of the World Association of Nuclear Operators (WANO), which means the mexican nuclear power plant is classified in terms of its performance indicators and above the average achieved by their counterparts americans and canadians. In the national context, the nuclear power plant of Laguna Verde has also been honored with several awards such as the National Quality Award, the Clean Industry Certificate, the distinction of Environmental Excellence and others of similar importance. For the standards of WANO, the basic idea is that there are shortcomings in one of nuclear power plant concern to all partners. The indicators used for the classification will always go beyond more compliance with regulations, which are assumed, and rather assume come or a path to excellence. Among the most important indicators are: the collective dose, the percentage of areas declared as contaminated, the number, type and tendency of contamination personal cases, the number of dosimetry alarms, the number of unplanned exposures, loss control of high radiation areas and the release of contaminated material outside the restricted areas. Furthermore, as already indicated, nuclear power plants are of special care situations, such as, carrying out work in areas with radiation fields of more than 15 mSv h{sup -1}, the movement of spent fuel in the reload floor. The consideration of the minimum total effective dose equivalent as a criterion for prescribing tools that reduce exposures, but may increase the external cases of contaminated casualties, the experience in portals such as workers subject to radiology, where exposure in industrial radiography, and so on. Special mention deserve the conditions generated during fuel reload stops, which causes a massive personnel movement, working simultaneously on

  8. Evaluation of cable ageing in Nuclear Power Plants; Evaluacion del envejecimiento de cables en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vergara, T. [Empresarios Agrupados, A. I. E. Madrid (Spain); Alonso Chicote, J. [TECNATOM, S. A. (Spain); Burnay, S. [AEA Technology (UK)

    2000-07-01

    The majority of power, control and instrumentation cables in nuclear power plants use polymers as their basic material for insulation and jacket. In many cases, these cables form part of safety-related circuits and should therefore be capable of operating correctly under both normal and accident conditions. Since polymeric materials are degraded by the long term action of the radiation and thermal environments found in the plant, it is important to be able to establish the cable condition during the plant lifetime. Nowadays there are a number of different methods to evaluate the remaining lifetime of cables. In the case of new plants, or new cables in old plants, accelerated ageing tests and predictive models can be used to establish the behaviour of the cable materials under operating conditions. There are verified techniques and considerable experience in the definition of predictive models. This type of approach is best carried out during the commissioning stage or in the early stages of operation. In older plants, particularly where there is a wide range of cable types in use, it is more appropriate to use condition monitoring methods to establish the state of degradation of cables in-plant. Over the last 10 years there have been considerable developments in methods for condition monitoring of cables and a tool-box of practical techniques are now available. There is no single technique which is suitable for all cable materials but the range of methods covers nearly all of the types currently in use, at present, the most established methods are the indented, thermal analysis (OIT, OITP and TGA) and dielectric loss measurements, All of these are either non-destructive methods or require only micro-samples of material. (Author) 15 refs.

  9. Qualification of programmed systems in power plants; Qualification des systemes programmes dans les centrales

    Energy Technology Data Exchange (ETDEWEB)

    Legras, A.; Quenot, D. [Sema Group (France)

    1999-04-01

    This paper deals with the control system software and drive units of the recent nuclear power plants. After a general presentation on the software utility and the constraints such as economical factors, safety or availability, the authors present the normative documents and the regulations. The third part is devoted to concrete examples showing the technical choices to obtain the wanted quality. Forecasted projects are included in the last part. (A.L.0008).

  10. Engineering for new-built nuclear power plant projects; Ingenieria para proyectos de nuevas centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Lopez, A.

    2012-11-01

    This article reviews the opportunities existing in the market (electrical utilities and reactor vendors) for an engineering company with the profile of Empresarios Agrupados (EA) in new-built nuclear power plant projects. To do this, reference is made to some representative examples of projects in which EA has been participating recently. the article concludes sharing with the reader some lessons learned from this participation. (Author)

  11. Chemical and radiochemical specifications - PWR power plants; Specifications chimiques et radiochimiques - Centrales REP

    Energy Technology Data Exchange (ETDEWEB)

    Stutzmann, A. [Electricite de France (EDF), 93 - Saint-Denis (France)

    1997-07-01

    Published by EDF this document gives the chemical specifications of the PWR (Pressurized Water Reactor) nuclear power plants. Among the chemical parameters, some have to be respected for the safety. These parameters are listed in the STE (Technical Specifications of Exploitation). The values to respect, the analysis frequencies and the time states of possible drops are noticed in this document with the motion STE under the concerned parameter. (A.L.B.)

  12. Thermodynamic cycles of nuclear power plants; Les cycles thermodynamiques des centrales nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Normand, T.; Andreani, J.; Tejedor, V.

    2010-07-01

    Above all a nuclear power plant is a thermal system whose efficiency relies on the thermodynamic cycle that turns the heat produced by the fission of uranium nuclei into electricity. The thermodynamic yield is an essential parameter to dimension a power plant. This book is dedicated to the presentation of the thermodynamic cycles that have been chosen in the different types of French PWR: CP0, P4, N4 and EPR. These cycles are classical steam cycles that have been used and optimized for 40 years, but they are physically limited and do not respond to the expectations of future generations of reactors. The last part deals with the thermodynamic cycles that might be involved in the fourth generation of nuclear reactors: cycles with super-critical steam, direct cycles for high temperature gas, indirect gas cycles, and cycles with super-critical CO{sub 2}. The first part of the book gives an account of the situation of nuclear power in France. (A.C.)

  13. CO2 capture processes in power plants - Le captage du CO2 dans les centrales thermiques

    OpenAIRE

    Bouallou, Chakib

    2010-01-01

    PDF file available for free at http://pubs.ub.ro/?pg=revues&rev=cscc6&num=201011&vol=1&aid=2975; International audience; This review is devoted to assess and compare various processes aiming at recover CO2 from power plants fed with natural gas (NGCC) and pulverized coal (PC). These processes are post combustion CO2 capture using chemical solvents, natural gas reforming for pre-combustion capture and oxy-fuel combustion with cryogenic recovery of CO2. These processes were evaluated to give so...

  14. Knowledge management in nuclear power plants; Gestion del conocimiento en las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Cal, C. de la; Barasoain, F.; Buedo, J. L.

    2013-03-01

    This article aims to show the importance of knowledge management from different perspectives. In this first part part of the article, the overall approach that performs CNAT of knowledge management is described. In the second part, a specific aspect of knowledge management in ANAV, tacit knowledge transfer is showed. finally, the third part discusses the strategies and actions that are followed in CNCO for knowledge management. All this aims to show an overview of knowledge management held in the Spanish Nuclear Power Plants. (Author)

  15. 10-MWe solar-thermal central-receiver pilot plant, solar facilities design integration: collector-field optimization report (RADL item 2-25)

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    Appropriate cost and performance models and computer codes have been developed to carry out the collector field optimization, as well as additional computer codes to define the actual heliostat locations in the optimized field and to compute in detail the performance to be expected of the defined field. The range of capabilities of the available optimization and performance codes is described. The role of the optimization code in the definition of the pilot plant is specified, and a complete description of the optimization process itself is given. The detailed cost model used by the optimizer for the commercial system optimization is presented in the form of equations relating the cost element to each of the factors that determine it. The design basis for the commercial system is presented together with the rationale for its selection. The development of the individual heliostat performance code is presented. Use of the individual heliostat code in a completed study of receiver panel power under sunrise startup conditions is described. The procedure whereby performance and heliostat spacing data from the representative commercial-scale system are converted into coefficients of use in the layout processor is described, and the actual procedure used in the layout processor is described. Numerous special studies in support of the pilot plant design are described. (LEW)

  16. Nuclear Power Plants (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Lyerly, Ray L.; Mitchell III, Walter [Southern Nuclear Engineering, Inc.

    1973-01-01

    Projected energy requirements for the future suggest that we must employ atomic energy to generate electric power or face depletion of our fossil-fuel resources—coal, oil, and gas. In short, both conservation and economic considerations will require us to use nuclear energy to generate the electricity that supports our civilization. Until we reach the time when nuclear power plants are as common as fossil-fueled or hydroelectric plants, many people will wonder how the nuclear plants work, how much they cost, where they are located, and what kinds of reactors they use. The purpose of this booklet is to answer these questions. In doing so, it will consider only central station plants, which are those that provide electric power for established utility systems.

  17. Strategies in tower solar power plant optimization

    OpenAIRE

    RAMOS, A.; RAMOS, F.

    2012-01-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of...

  18. Electrochemical techniques application in corrosion problems of fossil power plants; Aplicacion de tecnicas electroquimicas en problemas de corrosion en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Cano Castillo, Ulises; Garcia Ochoa, Esteban Miguel; Martinez Villafane, Alberto; Mariaca Rodriguez, Liboria; Malo Tamayo, Jose Maria; Uruchurtu Chavarin, Jorge [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    Some aspects of the electrochemical techniques employed to evaluate the corrosion at low temperature in fossil power plants are commented, as well as the results obtained with the application of them in three power plants of this type. [Espanol] Se comentan algunos aspectos de tecnicas electroquimicas utilizadas para evaluar la corrosion en baja temperatura en centrales termoelectricas, asi como los resultados de la aplicacion de las mismas en tres centrales de este tipo.

  19. A zero-power radio receiver.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert Wesley

    2004-09-01

    This report describes both a general methodology and some specific examples of passive radio receivers. A passive radio receiver uses no direct electrical power but makes sole use of the power available in the radio spectrum. These radio receivers are suitable as low data-rate receivers or passive alerting devices for standard, high power radio receivers. Some zero-power radio architectures exhibit significant improvements in range with the addition of very low power amplifiers or signal processing electronics. These ultra-low power radios are also discussed and compared to the purely zero-power approaches.

  20. Solar Central Receiver Prototype Heliostat. Volume II. Phase II planning (preliminary)

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-06-01

    A currently planned DOE program will develop and construct a 10 MW/sub e/ Pilot Plant to demonstrate the feasibility and operational characteristics of Solar Central Receiver Power Generation. The field of heliostats is a major element of the Solar Central Receiver Power Generation system. The primary objective of the program described is to establish and verify the manufacturability, performance, durability, and maintenance requirements of the commercial plant heliostat design. End products of the 16 month effort include: (1) design, fabrication, and test of heliostats; (2) preliminary designs of manufacturing, assembly, installation, and maintenance processes for quantity production; (3) detailed design of critical tooling or other special equipment for such processes; (4) refined cost estimates for heliostats and maintenance; and (5) an updated commercial plant heliostat preliminary design. The program management and control system is discussed. (WHK)

  1. Kansas Power Plants

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Power Plants database depicts, as point features, the locations of the various types of power plant locations in Kansas. The locations of the power plants...

  2. Gas power plants heat the public mind;Les centrales a gaz echauffent les esprits

    Energy Technology Data Exchange (ETDEWEB)

    Chauveau, L.

    2009-11-15

    Nuclear energy provides most part of the electricity produced in France but fossil thermal plants remain necessary to face peaking demand. The French government has planned to replace all the fossil plants by combined cycle gas plants that release far less CO{sub 2} than classic coal or oil plants. 31 new gas plants have been authorized and among them 2 are operating, 10 are being built and 8 are at the project stage. In some projects like in the little town of Verberie (Oise department) these projects are facing a strong local opposition. The objection of the opponents is two-fold: -) the plant will have a strong negative impact on the wild life particularly the population of boars and stags and -) this huge program of 31 gas plants contradict the government that committed itself to reduce the consumption of fossil energies and to favor renewable energies through its Grenelle environmental policy. (A.C.)

  3. Feasibility of the operation CFE`s conventional power plants for industrial cogeneration; Factibilidad de operar las centrales termoelectricas convencionales de la CFE para cogeneracion industrial

    Energy Technology Data Exchange (ETDEWEB)

    Buendia Dominguez, Eduardo H.; Acosta Torres, Rosa Aracely [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    An analysis is made on how cogeneration could help to maximize the power plant performance since thanks to cogeneration this type of power plants could utilize a part of the waste energy to be supplied to other processes. Also mention is made of the utilization of computer programs to help the design and the realization of functioning tests of this type of power plants. An economic evaluation is presented on the feasibility of operating this type of power plants as cogeneration units and it is concluded that the operation of fossil power plants in the cogeneration mode is not affected by the site where the power plant is located [Espanol] Se analiza como la cogeneracion podria ayudar a maximizar el rendimiento de las centrales termoelectricas ya que gracias a la cogeneracion este tipo de centrales podrian utilizar una parte de la energia desechada para suministrarla a otros procesos. Tambien se menciona la utilizacion de programas de computo para auxiliar en el diseno o realizacion de pruebas de funcionamiento sobre este tipo de plantas. Se presenta una evaluacion economica sobre la factibilidad de operar este tipo de plantas como unidades de cogeneracion y se concluye en que la operacion de centrales termoelectricas en modo de cogeneracion no se ve afectado por el sitio donde se encuentra la central

  4. Solar central electric power generation - A baseline design

    Science.gov (United States)

    Powell, J. C.

    1976-01-01

    The paper presents the conceptual technical baseline design of a solar electric power plant using the central receiver concept, and derives credible cost estimates from the baseline design. The major components of the plant - heliostats, tower, receiver, tower piping, and thermal storage - are discussed in terms of technical and cost information. The assumed peak plant output is 215 MW(e), over 4000 daylight hours. The contribution of total capital investment to energy cost is estimated to be about 55 mills per kwh in mid-1974 dollars.

  5. Operator training for the Yacyreta binational hydroelectric power plant; Formacion de operadores para la Central Hidroelectrica de Yacireta

    Energy Technology Data Exchange (ETDEWEB)

    Dure, Francisco; Tachella, Heriberto [Entidad Binacional Yacyreta, Isla Yacireta (Paraguay). Central Hidroelectrica Yacyreta]. E-mail: yacyreta@internet.siscotel.com

    1998-07-01

    This work is oriented to the power plant operators, by exposing the criteria and methods adopted for operators selection, training and incorporation to the Yacyreta Hydroelectric Power Plant. The used criteria considered some aspects, as follows: the operation staff should be consisted of equal numbers of Argentine and Paraguayan nationalities, viewing the both systems operation; experience of the shift supervisors in operating a plant for a minimum of 10 years; the supervisors should participate training the auxiliary operators.

  6. Modelling air quality impact of a biomass energy power plant in a mountain valley in Central Italy

    Science.gov (United States)

    Curci, Gabriele; Cinque, Giovanni; Tuccella, Paolo; Visconti, Guido; Verdecchia, Marco; Iarlori, Marco; Rizi, Vincenzo

    2012-12-01

    In this study, we investigate the potential impact on local air quality of a biomass power plant, which is planned for installation near L'Aquila, a city of 70,000 people located in a mountain valley in Central Italy. The assessment is carried out by applying a one year simulation with the CALPUFF model, following the recommendations of the U. S. Environmental Protection Agency. Meteorological input is produced with CALMET model, fed with both MM5 meteorological fields at 3 km resolution and wind observations from a surface weather station. We estimate small (<0.5 μg m-3) annual average increments to SO2, NO2 and PM10 ambient levels over the domain of interest, but significant (up to 50% for NO2) enhancements and several violations (up to 141 for NO2) of hourly limits for human protection within 1.5 km from the source. These results anticipate a larger negative effect on local air quality than those published by the building firm of the plant. We also suggest that a minimum distance of 5 km from the nearest residential area would represent a significant decrease of population exposure.

  7. Preparation of feasibility studies for nuclear power plants; Elaboracion de estudios de viabilidad de centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Andujar Sagredo, R.

    2013-07-01

    The feasibility study falls within the pre-purchase of a new nuclear plant jobs. This is a key process for the early identification of risks associated with the construction of the same, and the investment needed and the time within which such investment return, taking into account that this is a complex industrial project with an iron control and accurate high inputs of capital. Set the risks in these early stages of the project can make the difference in keeping both the budget and the execution time initially considered.

  8. Exergy analysis of thermoelectric power plants; Analisis exergetico de centrales termicas

    Energy Technology Data Exchange (ETDEWEB)

    Chejne J, Farid; Florez E, Whady F.; Ordonez R, Juan C.; Botero, G.; Edgar, A. [Universidad Pontificia Bolivariana, Medellin (Colombia). Grupo de Energia y Termodinamica

    1997-12-31

    An analysis of an electric energy generation plant based on first and second law of thermodynamics has been done. In this paper, a detailed approach to the concepts of quantity and quality of energy is presented. Usually, when energy is in an organized form (high quality energy like work), it does not degrade the environment, therefore, the associated cost to improve it is null. In contrast, the conversion process of unorganized energy (i.e. low quality such as heat), has an implicit impact on the surroundings. The analysis address the need for studying industrial processes having into account the availability or exergy in order to understand systems which degrade or destroy the quality of an energy resource. (author) 8 refs., 3 figs., 1 tab.; e-mail: fchejne at janua.upb.edu.co

  9. Power Plant Cycling Costs

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, N.; Besuner, P.; Lefton, S.; Agan, D.; Hilleman, D.

    2012-07-01

    This report provides a detailed review of the most up to date data available on power plant cycling costs. The primary objective of this report is to increase awareness of power plant cycling cost, the use of these costs in renewable integration studies and to stimulate debate between policymakers, system dispatchers, plant personnel and power utilities.

  10. Nuclear power plant of Fessenheim: evaluation of the seismic risk; Centrale Nucleaire de Fessenheim: appreciation du risque sismique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The seismic risk taken into account during the sizing of the nuclear power plant of Fessenheim seems to have been under evaluated at this time. The revaluation of the seismic risk, as proposed, until this day by EDF in order to the third ten-year visit of the power plant, planned for 2009, leads to a significant under evaluation of the risk and then is not acceptable. The present expertise details point by point the weaknesses of these revaluation. The power plant has been sized in an elastic manner that is generally strongly for the safety side. It is imperative to proceed the most quickly as possible to a deep control of the seismic resistance of the power plant of Fessenheim and then after having proceeded to a revision of the seismic risk in taking into account the actual knowledge in this field. (N.C.)

  11. Advanced Thermal Storage for Central Receivers with Supercritical Coolants

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Bruce D.

    2010-06-15

    The principal objective of the study is to determine if supercritical heat transport fluids in a central receiver power plant, in combination with ceramic thermocline storage systems, offer a reduction in levelized energy cost over a baseline nitrate salt concept. The baseline concept uses a nitrate salt receiver, two-tank (hot and cold) nitrate salt thermal storage, and a subcritical Rankine cycle. A total of 6 plant designs were analyzed, as follows: Plant Designation Receiver Fluid Thermal Storage Rankine Cycle Subcritical nitrate salt Nitrate salt Two tank nitrate salt Subcritical Supercritical nitrate salt Nitrate salt Two tank nitrate salt Supercritical Low temperature H2O Supercritical H2O Two tank nitrate salt Supercritical High temperature H2O Supercritical H2O Packed bed thermocline Supercritical Low temperature CO2 Supercritical CO2 Two tank nitrate salt Supercritical High temperature CO2 Supercritical CO2 Packed bed thermocline Supercritical Several conclusions have been drawn from the results of the study, as follows: 1) The use of supercritical H2O as the heat transport fluid in a packed bed thermocline is likely not a practical approach. The specific heat of the fluid is a strong function of the temperatures at values near 400 °C, and the temperature profile in the bed during a charging cycle is markedly different than the profile during a discharging cycle. 2) The use of supercritical CO2 as the heat transport fluid in a packed bed thermocline is judged to be technically feasible. Nonetheless, the high operating pressures for the supercritical fluid require the use of pressure vessels to contain the storage inventory. The unit cost of the two-tank nitrate salt system is approximately $24/kWht, while the unit cost of the high pressure thermocline system is nominally 10 times as high. 3) For the supercritical fluids, the outer crown temperatures of the receiver tubes are in the range of 700 to 800 °C. At temperatures of 700 °C and above

  12. Qualified Coatings in Nuclear Power Plants. Commercial products; Qualified Coatings in Nuclear Power Plants. Commercial products. Pinturas homologadas en centrales nucleares. Productos comerciales

    Energy Technology Data Exchange (ETDEWEB)

    Barcena, J.; Nunez, B.; Romero, M.; Baladiam, M.

    2014-07-01

    Recently, the supplier of paints that were qualified for use in nuclear applications as protective coatings have ceased to supply in Spain the paints that was used in areas or components with special requirements for nuclear power plants (NPPs). This lack of the common commercial products called for the search for and homologation of other products. A study was performed on the current status of the homologation of commercial products for NPPs and on the codes and standards governing them. The criteria to be met have been defined and the results of the tests performed on the selected paints have been compared against the established criteria so as to allow the homologation of the paints. (Author)

  13. Heat pipe central solar receiver. Volume I. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Bienert, W. B.; Wolf, D. A.

    1979-04-01

    The objective of this project was the conceptual design of a Central Solar Receiver Gas Turbine Plant which utilizes a high temperature heat pipe receiver. Technical and economic feasibility of such a plant was to be determined and preliminary overall cost estimates obtained. The second objective was the development of the necessary heat pipe technology to meet the requirements of this receiver. A heat pipe receiver is ideally suited for heating gases to high temperatures. The heat pipes are essentially loss free thermal diffusers which accept a high solar flux and transform it to a lower flux which is compatible with heat transferred to gases. The high flux capability reduces receiver heating surface, thereby reducing receiver heat losses. An open recuperative air cycle with a turbine inlet temperature of 816/sup 0/C (1500/sup 0/F) was chosen as the baseline design. This results in peak metal temperatures of about 870/sup 0/C (1600/sup 0/F). The receiver consists of nine modular panels which form the semicircular backwall of a cavity. Gas enters the panels at the bottom and exits from the top. Each panel carries 637 liquid metal heat pipes which are mounted at right angle to the gas flow. The evaporators of the heat pipes protrude from the flux absorbing front surface of the panels, and the finned condensors traverse the gas stream. Capital cost estimates were made for a 10 MW(e) pilot plant. The total projected costs, in mid-1978 dollars, range from $1,947 to $2,002 per electrical kilowatt. On the same basis, the cost of a water/steam solar plant is approximately 50% higher.

  14. Environmental management systems implemented in the Spanish nuclear power plants; Sistemas de gestion ambiental implantados en las centrales nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Redondo, R.; Fernandez Guisado, M. B.; Hortiguela, R.; Bustamante, L. F.; Esparza, J. L.; Villareal, M.; Yague, F.

    2013-09-01

    The companies that own the Spanish Nuclear Power Plants, aware of social concern and in the context of a growing demanding environmental legislation, have a permanent commitment to the electricity production based on the principles of a maximum respect for the environment, safety, quality, professionalism and continuous improvement. In order to minimize the environmental impact of their plants they have implemented and Environmental Management System based on the ISO 14001 Standard. They minimize the environmental impact by identifying the significant environmental aspects and defining the corresponding objectives. This article describes the referred environmental management systems and their environmental objectives, as applied and defined by the Spanish Nuclear Power Plants. (Author)

  15. Strategies in tower solar power plant optimization

    CERN Document Server

    Ramos, A

    2012-01-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of the algorithms and the resulting designs are studied for two typical cases. We describe a method to evaluate the impact of design variables in the plant performance. This method will tell us what variables are key to the optimal plant design and which ones are less important. This information can be used to further improve the plant design and to accelerate the optimization procedure.

  16. Strategies in tower solar power plant optimization

    Science.gov (United States)

    Ramos, A.; Ramos, F.

    2012-09-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of the algorithms and the resulting designs are studied for two typical cases. We describe a method to evaluate the impact of design variables in the plant performance. This method will tell us what variables are key to the optimal plant design and which ones are less important. This information can be used to further improve the plant design and to accelerate the optimization procedure.

  17. An assessment on hydrogen production using central receiver solar systems

    Science.gov (United States)

    Bilgen, C.; Bilgen, E.

    An assessment is presented on hydrogen production using a dedicated central receiver solar system concept coupled to two types of hydrogen producing processes, electrolysis and thermochemical. The study on solar electrolytic hydrogen was carried out using solar electricity and four different electrolytic technologies, namely, industrial unipolar 1980 and 1983 technologies, industrial bipolar and solid polymer electrolyte technology. The thermochemical process was the sulphur/iodine cycle, which is being developed by General Atomic Co. Systems, which is capable of producing about one-million GJ hydrogen per year, was developed at the conceptual level, and site specific computations were carried out. A general mathematical model was developed to predict the optical and thermal performance of the central receiver system coupled directly to the chemical plant. Cost models were developed for each subsystem based on the database published in the literature. Levelized and delevelized costs of solar hydrogen were then computed.

  18. Foreseeing techniques and control of emissions in thermal power plants. Workshop Latin American. [Selected Papers]; Control y tecnicas de prevision de las emisiones de centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Saldana, R.; Morales, F.; Urrutia, M. [eds.] [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    This document contains the conference proceedings of the Latin-American Workshop ``Control and Prevision Techniques of Emissions in Power Plants`` carried out in Cuernavaca, Mexico on June 1996, with the participation of representatives of Argentina, Chile, Guatemala, Colombia, Ecuador, Mexico, Nicaragua, Panama and Venezuela, as well as specialists from the European Union. The core issue analyzed in this workshop was the control and the evaluation techniques of polluting emissions in Power Plants [Espanol] Este documento contiene las memorias de conferencia del Taller Latinoamericano ``Control y tecnicas de prevision de las emisiones de centrales termoelectricas`` que se llevo a cabo en Cuernavaca, Mexico en junio de 1996. Participaron representantes de Argentina, Chile, Guatemala, Colombia, Ecuador, Mexico, Nicaragua, Panama y Venezuela, asi como especialistas de la Union Europea. El tema central tratado en este taller fue el control y tecnicas de evaluacion de las emisiones contaminantes en centrales termoelectricas

  19. Thermal resistance model for CSP central receivers

    Science.gov (United States)

    de Meyer, O. A. J.; Dinter, F.; Govender, S.

    2016-05-01

    The receiver design and heliostat field aiming strategy play a vital role in the heat transfer efficiency of the receiver. In molten salt external receivers, the common operating temperature of the heat transfer fluid or molten salt ranges between 285°C to 565°C. The optimum output temperature of 565°C is achieved by adjusting the mass flow rate of the molten salt through the receiver. The reflected solar radiation onto the receiver contributes to the temperature rise in the molten salt by means of heat transfer. By investigating published work on molten salt external receiver operating temperatures, corresponding receiver tube surface temperatures and heat losses, a model has been developed to obtain a detailed thermographic representation of the receiver. The steady state model uses a receiver flux map as input to determine: i) heat transfer fluid mass flow rate through the receiver to obtain the desired molten salt output temperature of 565°C, ii) receiver surface temperatures iii) receiver tube temperatures iv) receiver efficiency v) pressure drop across the receiver and vi) corresponding tube strain per panel.

  20. Analysis of pumping systems to large flows of cooling water in power plants; Analisis de sistemas de bombeo para grandes flujos de agua de enfriamiento en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Sanchez, Ramon; Herrera Velarde, Jose Ramon; Gonzalez Sanchez, Angel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: rsanchez@iie.org.mx; jrhv@iie.org.mx; ags@iie.org.mx

    2010-11-15

    Accurate measurement of large water flows remains being a challenge in the problems of implementation of circulating water systems of power plants and other applications. This paper, presents a methodology for the analysis in pumping systems with high rates of water in power plants, as well as their practical application and results in pipelines water flow of a thermoelectrical power plant of 350 MW. In this power plant, the water flow per pipeline for a half of condenser oscillates around 7 m{sup 3}/s (14 m{sup 3}/s per power generating unit). In this analysis, we present the techniques used to measure large flows of water with high accurately, as well as the computational model for water circulating system using PIPE FLO and the results of practical application techniques. [Spanish] La medicion precisa de grandes flujos de agua, sigue siendo un reto en los problemas de aplicacion de sistemas de agua de circulacion de centrales termoelectricas, entre otras aplicaciones. En este articulo, se presenta una metodologia para el analisis de sistemas de bombeo con grandes flujos de agua en centrales termoelectricas, asi como, su aplicacion practica y los resultados obtenidos en los ductos de agua de circulacion de una central generadora con unidades de 350 MW. En esta central, los flujos por caja de agua oscilan alrededor de los 7 m{sup 3}/s (14 m{sup 3}/s por unidad generadora). En el analisis, se presentan las tecnicas utilizadas para medir con precision grandes flujos de agua (tubo de Pitot), asi como, el modelado del sistema de agua de circulacion por medio de un paquete computacional (PIPE FLO) y resultados obtenidos de la aplicacion de dichas tecnicas.

  1. Nuclear Power Plants. Revised.

    Science.gov (United States)

    Lyerly, Ray L.; Mitchell, Walter, III

    This publication is one of a series of information booklets for the general public published by the United States Atomic Energy Commission. Among the topics discussed are: Why Use Nuclear Power?; From Atoms to Electricity; Reactor Types; Typical Plant Design Features; The Cost of Nuclear Power; Plants in the United States; Developments in Foreign…

  2. Power plant chemical technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    17 contributions covering topies of fossil fuel combustion, flue gas cleaning, power plant materials, corrosion, water/steam cycle chemistry, monitoring and control were presented at the annual meeting devoted to Power Plant Chemical Technology 1996 at Kolding (Denmark) 4-6 September 1996. (EG)

  3. Optical study of solar tower power plants

    Science.gov (United States)

    Eddhibi, F.; Ben Amara, M.; Balghouthi, M.; Guizani, A.

    2015-04-01

    The central receiver technology for electricity generation consists of concentrating solar radiation coming from the solar tracker field into a central receiver surface located on the top of the tower. The heliostat field is constituted of a big number of reflective mirrors; each heliostat tracks the sun individually and reflects the sunlight to a focal point. Therefore, the heliostat should be positioned with high precision in order to minimize optical losses. In the current work, a mathematical model for the analysis of the optical efficiency of solar tower field power plant is proposed. The impact of the different factors which influence the optical efficiency is analyzed. These parameters are mainly, the shading and blocking losses, the cosine effect, the atmospheric attenuation and the spillage losses. A new method for the calculation of blocking and shadowing efficiency is introduced and validated by open literature.

  4. The Kuroshio power plant

    CERN Document Server

    Chen, Falin

    2013-01-01

    By outlining a new design or the Kuroshio power plant, new approaches to turbine design, anchorage system planning, deep sea marine engineering and power plant operations and maintenance are explored and suggested. The impact on the local environment, particularly in the face of natural disasters, is also considered to provide a well rounded introduction to plan and build a 30MW pilot power plant. Following a literature review, the six chapters of this book propose a conceptual design by focusing on the plant's core technologies and establish the separate analysis logics for turbine design and

  5. Treatment of operational experience of nuclear power plants in WANO; Tratamiento de la experiencia operativa de las centrales nucleares en WANO

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, M.

    2013-09-01

    The article describes the activities associated to the Operating Experience Programme of the World Association of Nuclear Operators. The programme manages the event reports submitted by the nuclear power plants to the WANO database for the preparation by the Operating Experience Central Team of some documents like the significant Operating Experience Reports and Significant Event Reports that help the stations to avoid similar events. (Author)

  6. Solar central receiver prototype heliostat CDRL item B. d. Final technical report, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Easton, C. R.

    1978-08-01

    This is volume II of a two volume report which presents the results of a study to define a low-cost approach to the production, installation, and operation of heliostats for central receiver solar thermal power plants. Performance and cost analyses are presented, and critical R and D areas are identified. Also, computer printed work sheets are included for heliostat investment, maintenance equipment investment, initial spares investment, and first years operations and maintenance for 2,500, 25,000, 250,000, and 1,000,000 units per year production. (WHK)

  7. NCI Central Review Board Receives Accreditation

    Science.gov (United States)

    The Association for the Accreditation of Human Research Protection Programs has awarded the NCI Central Institutional Review Board full accreditation. AAHRPP awards accreditation to organizations demonstrating the highest ethical standards in clinical res

  8. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self‐funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty‐three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  9. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University's aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  10. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  11. Modular plant of electro chlorination of seawater for nuclear power plants; Planta modular de electrocloracion de agua de mar para centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, H.; Sesma, J. L.

    2015-07-01

    Iberdola Engineering and Construction has supplied the seawater electro chlorination plant for the EPR of Flamanville 3. The plant produces sodium hypochlorite from the electrolysis of the seawater and injects it continuously to protect the cooling circuits against the marine flora and fauna. As a consequence of the problems faced during the erection of the plant, Iberdola Engineering and construction develops an innovation project to design a modular electro chlorination system for Nuclear Power Plants. The result is a competitive product that reduces significantly the installation costs and the delivery data. (Author)

  12. Nuclear power plant maintainability.

    Science.gov (United States)

    Seminara, J L; Parsons, S O

    1982-09-01

    In the mid-1970s a general awareness of human factors engineering deficiencies associated with power plant control rooms took shape and the Electric Power Research Institute (EPRI) awarded the Lockheed Corporation a contract to review the human factors aspects of five representative operational control rooms and their associated simulators. This investigation revealed a host of major and minor deficiencies that assumed unforeseen dimensions in the post- Three Mile Island accident period. In the course of examining operational problems (Seminara et al, 1976) and subsequently the methods for overcoming such problems (Seminara et al, 1979, 1980) indications surfaced that power plants were far from ideal in meeting the needs of maintenance personnel. Accordingly, EPRI sponsored an investigation of the human factors aspects of power plant maintainability (Seminara, 1981). This paper provides an overview of the maintainability problems and issues encountered in the course of reviewing five nuclear power plants.

  13. Geochemistry of the recent sediments from lake in the vicinity of the coal-fired power plants in Central Alberta, Canada

    Energy Technology Data Exchange (ETDEWEB)

    H. Sanei; F. Goodarzi; K. Telmer [Geological Survey of Canada, Calgary, AB (Canada). Environmental Study Group

    2005-07-01

    This study investigates the geochemical characteristics of recent sediments and their porewaters from the Wabamun Lake in central Alberta (Canada) to elucidate the possible impact from coal utilization in this region. A multi-elemental analysis of recent sediments in conjunction with other inorganic and organic geochemical approaches are applied to determine the sources, quantity, and processes involved in the distribution of trace elements in the sediments. Concentration versus depth profiles in the sediments and the associated porewaters suggest that geochemical processes impact the mobility and vertical distribution of trace elements in these sediments. Although inputs of trace elements to ecosystems have clearly been elevated by emissions from the coal-fired power plants, diagenetic processes and natural inputs cannot be ignored in the distribution of lake sediments. A combination of various biogeochemical processes may control the distribution of elements in sediment and porewater. However, because of the alkalinity and eutrophic conditions of the studied lake, the Ca-OM fraction plays the most important role as substrate for trace elements. The higher input of calcareous fly ash in the Wabamun Lake, adjacent to the power plants, may cause scavenging of trace metals. The size of fly ash particles tends to decrease towards the more recent part of the sediment profile indicating the effect of particle emission control measures adopted by the power plants. There is no evidence of fly ash particles in the sediments deposited prior to the commencement of coal-fired power plants in the study area (before 1956).

  14. Advanced stellarator power plants

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.L.

    1994-07-01

    The stellarator is a class of helical/toroidal magnetic fusion devices. Recent international progress in stellarator power plant conceptual design is reviewed and comparisons in the areas of physics, engineering, and economics are made with recent tokamak design studies.

  15. Fatigue damage in nuclear power plants: cases study; Endommagement par fatigue dans les centrales nucleaires: illustration par quelques cas rencontres

    Energy Technology Data Exchange (ETDEWEB)

    Goltrant, O.; Thebault, Y. [Electricite de France (EDF/GDL), 93 - Saint-Denis (France). Groupe des Labs; Cipiere, M.F. [FRAMATOME, 92 - Paris-La-Defense (France)

    2001-07-01

    Some fatigue cracks have been detected on nuclear power plants components. Generally they appears under local solicitations not correctly predicted. Two cases are presented in this paper to illustrate the problem: the pitting during mechanical fatigue where the stresses are induced by the pumps vibrations or by fluid flow; the mixing zones of RRA circuit (N4 bearing) where the stresses are induced by the flow of different temperature fluids. The examination allowed the identification of the cracking origin and the development of corrective solutions. (A.L.B.)

  16. Safe closure for the Barsebaeck Nuclear Power Plant (Sweden); Clasusura segura de la central nuclear de Barseback (Suecia)

    Energy Technology Data Exchange (ETDEWEB)

    Lexberg, A.

    2003-07-01

    In February, 1998, the Swedish Government entrusted the Swedish Regulatory Body (SKI) with the supervision of the first shut-down of the two reactors at the Barsebaeck Nuclear Power Plant, which finally took place in November of 1999. Now that the data of the closure of the second reactor is uncertain, but assured, there arises and uncertainty brought about by the prolonged decision making process, which may be detrimental to the safety culture at the site, reduce motivation and cause the loss of key personnel. (Author)

  17. 八达岭太阳能塔式热发电吸热器水动力特性仿真研究%Hydrodynamic Characteristics and Operation Security Study of Solar Receiver for Badaling Solar Tower Power Plant

    Institute of Scientific and Technical Information of China (English)

    高维; 徐蕙; 徐二树; 余强

    2012-01-01

    This paper took overheating cavity receiver of Badaling 1 MW solar power tower plant as study object, developed a hydrodynamic simulation model for receiver based on the working principle of the superheating cavity receiver, simulated the hydrodynamic characteristics of cavity receiver, and obtained the change law of working medium mass flow in different heating surfaces with solar radiation. The results can provide some guidance to design the receiver system and to formulate the control and operating strategy for solar power tower plant.%本文以八达岭塔式太阳能热发电实验电站腔式吸热器为研究对象,根据吸热器的结构和工作原理,利用热力学定律建立了吸热器系统水动力仿真数学模型,模拟了吸热器蒸发受热面系统内工质的流动,通过吸热器水动力的仿真实验从而得到在不同的太阳辐照强度下吸热器蒸发受热面入口流量的分配规律。论文结论对实际太阳能热发电站吸热器的设计及安全运行具有指导意义。

  18. Power plant siting

    Energy Technology Data Exchange (ETDEWEB)

    Winter, J.V.; Conner, D.A.

    1978-01-01

    Just to keep up with expected demand, the US will need over 500 new power generation units by 1985. Where these power plants will be located is the subject of heated debate among utility officials, government leaders, conservationists, concerned citizens and a multitude of special interest groups. This book offers a balanced review of all of the salient factors that must be taken into consideration in selecting power plant locations. To deal with this enormously complex subject, the authors (1) offer a general overview of the history and reasoning behind present legislation on the state and national levels; (2) describe the many different agencies that have jurisdiction in power plant location, from local water authorities and city councils to state conservation boards and the Nuclear Regulatory Commission; and (3) include a state-by-state breakdown of siting laws, regulations and present licensing procedures. Architects, engineers, contractors, and others involved in plant construction and site evaluation will learn of the trade-offs that must be made in balancing the engineering, economic, and environmental impacts of plant location. The book covers such areas as availability of water supplies for generation or cooling; geology, typography, and demography of the proposed site; and even the selection of the fuel best suited for the area. Finally, the authors examine the numerous environmental aspects of power plant siting.

  19. Modernisation of power plants in central and eastern Europe: High demand for creativity; Modernisierung von Kraftwerken in Mittel- und Osteuropa: Viel Kreativitaet gefragt

    Energy Technology Data Exchange (ETDEWEB)

    Schwegmann, P.

    1998-07-01

    The retrofitting of old power plants in central and eastern Europe is a task of enormous dimensions and great importance. As all governments there are low in funds, measures to extend service life of the plants are an essential economic alternative to erecting new plants. The demand for retrofitting work opens up good marketing chances for power plant manufacturers of the West on the basis of cooperation agreements with domestic plant manufacturers in those countries, as is shown by the activities of Siemens/KWU. Now as before, creativity is much in demand for solving a substantial problem, the financing of retrofitting projects. (orig./CB) [Deutsch] Die Rekonstruktion alter Kraftwerke in Mittel- und Osteuropa ist eine Aufgabe von enormem Ausmass und grosser Bedeutung. Lebensdauerverlaengernde Massnahmen sind angesichts knapper Finanzen eine wirtschaftliche Alternative zum Anlagenneubau. Gute Marktchancen eroeffnen sich westlichen Firmen durch Kooperationen mit oestlichen Anlagenbauern, wie das Beispiel Siemens/KWU zeigt. Bei der Finanzierung von Projekten ist nach wie vor Phantasie gefragt. (orig.)

  20. Environmental management in Chile: The power plants case; Gestion ambiental en Chile: Caso de las centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Jadrijevic, Maritza [Comision Nacional del Medio Ambiente, (Chile)

    1996-12-31

    In this paper are presented the general aspects of the historic evolution o the legal norms on environmental matters in Chile; general aspects of the electric generation system and the instruments of environmental management currently applied in the fossil fueled power plants, such as: the assessment system of the environmental impact; compliance of the air quality and emissions Standards and plans for decontamination [Espanol] En este trabajo se dan a conocer aspectos generales de la evolucion historica de las normas juridicas en materia ambiental en Chile; aspectos generales del sistema de generacion electrica y los instrumentos de gestion ambiental que actualmente se aplican a las plantas de generacion termoelectricas, tales como: el sistema de evaluacion de impacto ambiental; cumplimiento de normas de la calidad de aire y de emision y, planes de descontaminacion

  1. Current status of the Colombia power plants emissions; Estado de las emisiones en las centrales termoelectricas de Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Quijano Hurtado, Ricardo [Ministerio de Minas y Energia, (Colombia)

    1996-12-31

    The characteristics of the Colombian thermal electric resource and the environmental characteristics of the region such as: the climate where the power plants are located; the Geology and the type of soils; the technology employed for the atmospheric emissions control; the water consumption in the region; the systems for ash extraction an social-economical aspects are described [Espanol] Se describen las caracteristicas del parque termico de Colombia y las caracteristicas ambientales de la region como son: el clima donde estan localizadas las plantas; la geologia y los tipos de suelos; la tecnologia utilizada en el control de las emisiones atmosfericas; el consumo de agua en la region; los sistemas de extraccion de cenizas y aspectos socioeconomicos

  2. Solution to the colloidal silica problem in the San Luis Potosi power plant; Solucion del problema de silice coloidal en la central termoelectrica San Luis Potosi

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Rubalcava, Humberto [Comision Federal de Electricidad (CFE), Mexico, D. F. (Mexico); Mercado, Sergio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Guerra, Protasio [Comision Federal de Electricidad (CFE), Mexico, D. F. (Mexico)

    1988-12-31

    In June 1986 the Comision Federal de Electricidad (CFE) made tests to raise the load of the first normalized unit of 350 MW of the San Luis Potosi Power Plant; although the new system for colloidal silica removal had not yet been installed, consisting of a hollow fibers ultra-filtration system with a capacity of 110 m{sup 3}, that for the first time would be applied in a Mexican power plant. It was decided to install this system due to the fact that the well water supplying this power plant comes from a geothermal reservoir, with water at 38 degrees Celsius and a silica content of 15 to 250 parts per billion (ppb) of colloidal silica, which makes it necessary to eliminate it in order to enable the boiler operation at its design conditions (175 bars (2573 psig) and 540 degrees Celsius). Although a demineralizing plant existed for the boiler feed water make up, the ion exchange resins were not able to retain the colloidal silica. Also, the First Unit operation was held at 25% of its rated capacity; in trying to raise the output to 50%, the silica concentration in the boiler water went over the allowed limits, resulting in a concentration of 1,500 ppb in the boiler water and 28 ppb in the steam. One the ultra-filtration plant was installed, the power plant operated at full rated capacity with silica concentrations in the steam lower than the permitted concentration, i.e. 10 ppb . By the end of 1987 the Second Unit of 350 MW was put into operation with the ultra-filtration system in operation, reaching full load without any problem. Once confirmed the efficiency of the ultra-filtration for the colloidal silica removal, CFE will apply this system in other power plants of the country having the same problem. [Espanol] En junio de 1986, la Comision Federal de Electricidad (CFE) efectuo pruebas de elevacion de carga en la primera unidad normalizada de 350 MW de la central termoelectrica San Luis Potosi; sin embargo, aun no se terminaba de instalar el nuevo sistema para la

  3. Statistical analysis about corrosion in nuclear power plants; Analisis estadistico de la corrosion en centrales nucleares de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Naquid G, C.; Medina F, A.; Zamora R, L. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencia de Materiales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    Nowadays, it has been carried out the investigations related with the structure degradation mechanisms, systems or and components in the nuclear power plants, since a lot of the involved processes are the responsible of the reliability of these ones, of the integrity of their components, of the safety aspects and others. This work presents the statistics of the studies related with materials corrosion in its wide variety and specific mechanisms. These exist at world level in the PWR, BWR, and WWER reactors, analysing the AIRS (Advanced Incident Reporting System) during the period between 1993-1998 in the two first plants in during the period between 1982-1995 for the WWER. The factors identification allows characterize them as those which apply, they are what have happen by the presence of some corrosion mechanism. Those which not apply, these are due to incidental by natural factors, mechanical failures and human errors. Finally, the total number of cases analysed, they correspond to the total cases which apply and not apply. (Author)

  4. Generalized conventional and intelligent supervisory control system for combined cycle generation power plants; Sistema de control supervisorio generalizado convencional e inteligente para centrales de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Morales, Miguel Angel

    2004-12-15

    The Mexican Electricity Utility (Comision Federal de Electricidad - CFE) growing program in Power Generation for the 2004 - 2008 period is based on Combined Cycle Power Plants (CCPP). In accordance with [CFE, 2000], the expected power generation capacity developed during such period will rise by the amount of 12876 MW, 10655 MW belonging to CCPP (82.75 %). With such important program for the increasing of Power Generation in Mexico, researches have to receive new technologies for CCPP, some of them not completely tested and immature, with the compromise to make then more efficient and reliable. Under such idea and looking to increase the automation level for CCPP with better control algorithms, the Supervisory Generalized Control (SGC) for CCPP was developed in this thesis, based on PID strategies and intelligent (fuzzy) control strategies. With the SGC is possible to get the best performance for the whole CCPP through the automatic starting, synchronizing and loading of the generating units (two gas turbines and one steam turbine) with a minimum participation of operators. To get the increased efficiency, the SGC generates the reference paths for both gas turbines (GT) first, and the steam turbine (ST). The SGC accelerates each unit with a minimum effort and vibrations getting the synchronizing speed in a minimum time and wasted energy. Then the SGC synchronize each unit taking minimum load quickly and loading up to the highest electric power value. All these can be done in an automated operation. The SGC employs two critical-process variable- control strategies, based on blade path temperature average (BPT Average) for Gas Turbines (GT) and the throttle steam pressure for the Steam Turbine (ST). The control algorithms designed take both units, the GT and the ST, picking up load to the highest process value avoiding the alarms activation and shutdown. This is possible only with such an automated control strategy. Test performed showed that with the SGC

  5. Environmental management project of the Patache power plant project and associated transmission line; Gestion ambiental proyecto central termoelectrica Patache y linea de transmision asociada

    Energy Technology Data Exchange (ETDEWEB)

    Carreno Paredes, Cristian [Compania Electrica Tapaca (CELTA, S. A.), (Chile)

    1996-12-31

    This report makes a brief description of the services developed by INGENDESA of the projects executed in the area of engineering as well as in the area of environmental matters. In a second instance a relatively detailed presentation is made of the most important background of the Chilean project: {sup E}nvironmental Management of the Patache Power Plant and the Associated Transmission Line-Compania Electrica Tarapaca (CELTA, S.A.) Region I{sup .} The justification for the construction of the power plant and the environmental problems associated with the same are described [Espanol] En el presente informe se hace una breve presentacion de los servicios desarrollados por INGENDESA, de los proyectos elaborados tanto en el area de la ingenieria como en la tematica ambiental. En segunda instancia, se hace una presentacion relativamente detallada de los antecedentes mas importantes del proyecto chileno {sup G}estion Ambiental Central Patache y Linea de Transmision Asociada - Compania Electrica Tarapaca (CELTA, S.A.) I Region{sup .} Se describe la justificacion de la construccion de esta central termoelectrica y los problemas ambientales asociados a la misma

  6. GEOTHERMAL POWER GENERATION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196oF resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  7. Geothermal Power Generation Plant

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya [Oregon Inst. of Technology, Klamath Falls, OR (United States). Geo-Heat Center

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  8. Nuclear Power Plant Technician

    Science.gov (United States)

    Randall, George A.

    1975-01-01

    The author recognizes a body of basic knowledge in nuclear power plant technoogy that can be taught in school programs, and lists the various courses, aiming to fill the anticipated need for nuclear-trained manpower--persons holding an associate degree in engineering technology. (Author/BP)

  9. Statistical analysis of the wind around a nuclear power plant; Analisis estadistico del viento alrededor de una central nucleoelectrica

    Energy Technology Data Exchange (ETDEWEB)

    Tejeda, A; Alvarez, Oscar; Contreras, A. D.; Jauregui, E. [Universidad Veracruzana, (Mexico)

    1996-12-31

    In order to show an appropriate methodology for the climatic analysis of the wind, some of the recent results in the investigation of the field flow around the Laguna Verde Nuclear Power Station, at Veracruz State (Mexico,) through the angular correlation coefficients and contingency tables among the registered wind directions by a meteorological tower at the levels of 10 and 60 meters high are presented. Finally, by applying an objective analysis of the data some conclusions are obtained in connection with the local winds with the mesoscale systems. [Espanol] Con el objeto de mostrar una metodologia apropiada en el analisis climatico del viento, se presentan algunos resultados recientes en la investigacion del campo de flujo en los alrededores de la central nucleoelectrica de Laguna Verde, Veracruz (Mexico), a traves de los coeficientes de correlacion angulares y de tablas de contingencia entre las direcciones del viento registradas por una torre meteorologica en los niveles de 10 y 60 metros de altura. Finalmente, aplicando analisis objetivo de los datos, se obtienen algunas conclusiones sobre la conexion de los vientos locales con los sistemas de mesoescala.

  10. Ageing of power plants socio-economical, sanitary and environmental impact; Veillissement des centrales Impacts socio-economiques, sanitaires et environnementaux

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, Ch. [Depute du nord (France); Denner, M. [EDF pour la Region Bourgogne (France); Vouilloux, F. [Institut de Radioprotection et de Surete Nucleaire, 92 - Fontenay-aux-Roses (France); Foucher, L. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Serviere, M. [Electricite de France (EDF), 75 - Paris (France); Vila d' Abadal Serra, M

    2005-07-01

    The National Association of the local Commissions of Information (A.N.C.L.I.) presents a colloquium about the ageing of nuclear power plants. The different following points are presented. The life cycle of nuclear power plants and the new types of reactors. The ageing of power plants: stakes and perspectives for the French and world nuclear park. A power plant of 30 years is it sure? The role of the studies of ageing and the follow-up according to the age. Stop or continue to exploit a nuclear power plant: who decides, when and how. The socio-economic consequences of a stop of power plant: the Spanish experience. Ten-year visits of a power plant: the associative experience. 58 reactors today: how to assume their end of life and welcome equipments to come. (N.C.)

  11. Reliability of the Solar One plant during the power production phase.

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, Gregory J.; Lopez, Charles W.

    1989-01-01

    Solar One is the world's largest central receiver power plant. During the last 4 years the plant availability was 80%, 83%, and 96%, respectively, during hours of sunshine. This reliability is considered to be excellent considering the plant is a first-of-a-kind facility and because it has been subjected to daily cyclic service. In this paper we present the frequencies and causes of the plant outages that occurred. The ten most important causes comprised 72% of the total outage time. Qualitative insights related to the cause and mitigation of these ten are provided. The information presented in this paper will be useful to studies aimed at improving the reliability of future solar central receiver power plants. It is also useful to members of the utility industry who are considering investing in this technology or are considering cyclic operation of conventional power plants. 4 refs., 3 figs.

  12. Heat pipe central solar receiver. Semiannual progress report, September 1, 1976--May 31, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Bienert, W. B.; Wolf, D. A.

    1977-09-01

    It is proposed to develop a solar-to-gas heat exchanger for a Central Solar Receiver Power Plant. The concept employs heat pipes to transfer the concentrated solar flux to the gaseous working medium of a Brayton cycle conversion system. During early phases of the program, an open air cycle with recuperator and a turbine inlet temperature of 800/sup 0/C was selected as the optimum design. The predicted cycle efficiency is 33 percent and the overall solar-to-electric efficiency is 20 percent. Three potential receiver configurations were also identified during the initial phases of the program. Optimum heat pipe diameter is approximately 5 cm for all three receiver configurations, and typical lengths are 2 to 3 meters. The required number of heat pipes for a 10 MWe receiver ranges from 2000 to 8000. Heat transport requirements per pipe vary from 4 to 18 Kw. Several wick structures were developed and evaluated in subscale heat pipe tests using sodium as the working fluid. One full scale heat pipe (5 cm diameter by 183 cm long) was developed and tested with sodium as the working fluid.

  13. A solar power plant

    Energy Technology Data Exchange (ETDEWEB)

    Avakyan, Yu.V.; Dabagyan, T.N.; Gagiyan, L.A.; Kharapetyan, G.S.; Vartanyan, A.V.

    1984-01-01

    This invention is designed for solar energy collectors in the form of heat pipes. A solar power plant is proposed that contains a solar concentrator in the form of at least one heat pipe with evaporation and condensation sections, the first of which is constructed to absorb solar emission and the second located in a heat exchanger equipped with inlet and outlet pipes. In order to simplify the design, the solar power plant is equipped with an additional heat exchanger connected through a connector to the inlet and outlet pipes, while the evaporation section holds an additional section in the lower half, within the auxiliary heat exchanger. During operation as a solar energy collector, the evaporation region absorbs the solar energy and converts it to heat, which is then carried by the heat transfer medium to the heating tube.

  14. Reproduction of the flow-power map of the Laguna Verde power plant; Reproduccion del mapa flujo-potencia de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R.; Gonzalez M, V.M. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1993-07-01

    The National Commission of Nuclear Safety and Safeguards (CNSNS) requires to have calculation tools which allows it to make analysis independent of the behavior of the reactor core of Laguna Verde nuclear power plant (CNLV) with the purpose to support the evaluation and discharge activities of the fuel recharges licensing. The software package Fms (Fuel Management System) allows to carry out an analysis of the core of the BWR type reactors along the operation cycle to detect possible anomalies and/or helping in the fuel management. In this work it is reproduced the flow-power for the CNLV using the Presto code of the Fms software package. The comparison of results with the map used by the operators of CNLV shows good agreement between them. Another exercise carried out was the changes study that the axial and radial power outlines undergo as well as the thermohydraulic parameters (LHGR, APLHGR, CPR) when moving a control rod. The obtained results show that is had the experience to effect analysis of the reactor behavior using the Presto-Fms code therefore the study of the rest of the software package for the obtention of nuclear parameters used in this code is recommended. (Author)

  15. Application of Pressure Equipment Standard at nuclear power plants; Aplicacion del Reglamento de Equipos a Presion a las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Mostaza, J. M.

    2011-07-01

    Regarding with the paper presented on 9{sup t}h June 2011 referred to the Industrial Security standard in Nuclear Plants, it was about the application of Pressure Equipment standard to mentioned Nuclear Plants, this article is an extract of the paper going to be exposed. (Author)

  16. Tri-Lateral Noor al Salaam High Concentration Solar Central Receiver Program

    Energy Technology Data Exchange (ETDEWEB)

    Blackmon, James B

    2008-03-31

    This report documents the efforts conducted primarily under the Noor al Salaam (“Light of Peace”) program under DOE GRANT NUMBER DE-FC36-02GO12030, together with relevant technical results from a closely related technology development effort, the U.S./Israel Science and Technology Foundation (USISTF) High Concentration Solar Central Receiver program. These efforts involved preliminary design, development, and test of selected prototype power production subsystems and documentation of an initial version of the system definition for a high concentration solar hybrid/gas electrical power plant to be built in Zaafarana, Egypt as a first step in planned commercialization. A major part of the planned work was halted in 2007 with an amendment in October 2007 requiring that we complete the technical effort by December 31, 2007 and provide a final report to DOE within the following 90 days. This document summarizes the work conducted. The USISTF program was a 50/50 cost-shared program supported by the Department of Commerce through the U.S./Israel Science and Technology Commission (USISTC). The USISTC was cooperatively developed by President Clinton and the late Prime Minister Rabin of Israel "to encourage technological collaboration" and "support peace in the Middle East through economic development". The program was conducted as a follow-on effort to Israel's Magnet/CONSOLAR Program, which was an advanced development effort to design, fabricate, and test a solar central receiver and secondary optics for a "beam down" central receiver concept. The status of these hardware development programs is reviewed, since they form the basis for the Noor al Salaam program. Descriptions are provided of the integrated system and the major subsystems, including the heliostat, the high temperature air receiver, the power conversion unit, tower and tower reflector, compound parabolic concentrator, and the master control system. One objective of the USISTF program was to conduct

  17. Revision of by-laws about effluents of EdF's nuclear power plants; Revision des arretes de rejets des centrales nucleaires d'EDF

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    In France, in application of the clean water law from January 3, 1992 and since the decree 95-540 from May 4, 1995, each basic nuclear facility receives a single permission which covers both its water takes and its radioactive and non-radioactive effluents. This decree, initially dedicated to new facilities has been enlarged to all existing installations for which the prefectorial by-laws have reached their date-line. Thus, up to now, five inter-ministerial by-laws have renewed the permissions of water takes and effluents evacuation of the power plants of Saint-Laurent-des-Eaux (Loir-et-Cher), Flamanville (Manche), Paluel (Seine-Maritime), Belleville (Cher) and Saint-Alban (Isere). These by-laws foresee an important abatement of the effluents and concern more particularly the tritium, {sup 14}C, the iodine isotopes and also some other non-radioactive chemical compounds. This document is a compilation of all revised by-laws about effluents and concerning the nuclear power plants listed above. (J.S.)

  18. Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Analia Bonelli

    2012-01-01

    Full Text Available A description of the results for a Station Black-Out analysis for Atucha 2 Nuclear Power Plant is presented here. Calculations were performed with MELCOR 1.8.6 YV3165 Code. Atucha 2 is a pressurized heavy water reactor, cooled and moderated with heavy water, by two separate systems, presently under final construction in Argentina. The initiating event is loss of power, accompanied by the failure of four out of four diesel generators. All remaining plant safety systems are supposed to be available. It is assumed that during the Station Black-Out sequence the first pressurizer safety valve fails stuck open after 3 cycles of water release, respectively, 17 cycles in total. During the transient, the water in the fuel channels evaporates first while the moderator tank is still partially full. The moderator tank inventory acts as a temporary heat sink for the decay heat, which is evacuated through conduction and radiation heat transfer, delaying core degradation. This feature, together with the large volume of the steel filler pieces in the lower plenum and a high primary system volume to thermal power ratio, derives in a very slow transient in which RPV failure time is four to five times larger than that of other German PWRs.

  19. Current power plant

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, J.H.

    1979-03-06

    A current power plant is described that includes a shaft mounted turbine wheel for employment in water current, a housing adjacent the impeller and to which the shaft extends, a ramp positioned on the upstream side of the impellar, and a frame on which the turbine wheel is mounted. The frame is mounted by rollers on a tract such that the impeller and frame may be rolled on the tracks inside the housing, whereafter doors are closed, and water around the turbine wheel may be pumped out to facilitate turbine repair.

  20. Central-Receiver Solar-Thermal Power System 10-MW/sub e/ Pilot Plant: collector subsystem manufacturing plan report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-09-15

    The overall manufacturing planning effort included: design modification analysis; manufacturing/tooling conceptual trades; process/tooling verification experiments; and documentation of manufacturing plans and cost estimates. Innovative tooling concepts were evaluated. Studies also included comparison of costs of both field and shop assembly of heliostats.

  1. Production and Use of Densified Refuse-Derived Fuel (DRDF) in Military Central Heating and Power Plants.

    Science.gov (United States)

    1980-03-01

    facility in Los cations required for its reliable use. Subsequently, Gatos , CA. Nearly 21 tons of this material were fired in reasonably reliable cost... bacteria , viruses, and present. pathogens. Research at the Ames, Iowa, resource recov- ery facility found airborne bacteria counts in the plant There has...analysis cated that most of the bacteria (>90 percent of the procedures used render these results inconclusive. The fecal coliform) were associated with the

  2. Wind power plant system services

    DEFF Research Database (Denmark)

    Basit, Abdul; Altin, Müfit

    Traditionally, conventional power plants have the task to support the power system, by supplying power balancing services. These services are required by the power system operators in order to secure a safe and reliable operation of the power system. However, as in the future the wind power...... is going more and more to replace conventional power plants, the sources of conventional reserve available to the system will be reduced and fewer conventional plants will be available on-line to share the regulation burden. The reliable operation of highly wind power integrated power system might......, in a modern power system with large scale integration wind power. This study presents the investigation of the real-time balance control in a modern Danish power system, where WPPs can actively contribute to active power balance control. New solutions for the automatic generation control (AGC) dealing...

  3. Theory of cellwise optimization for solar central receiver system

    Science.gov (United States)

    Lipps, F. W.

    1985-05-01

    Cost effective optimization of the solar central receiver system is primarily concerned with the distribution of heliostats in the collector field, including the boundaries of the field. The cellwise optimization procedure determines the optimum cell usage and heliostat spacing parameters for each cell in the collector field. Spacing parameters determine the heliostat density and neighborhood structure uniformly in each cell. Consequently, the cellwise approach ignores heliostat mismatch at cell boundaries. Ignoring the cell boundary problem permits an easy solution for the optimum in terms of appropriately defined annual average data. Insolation, receiver interception, shading and blocking, cosine effects, and the cost parameters combine to control the optimum. Many trade offs are represented. Outputs include the receiver flux density distribution for design time, coefficients for an actual layout, the optimum boundary and various performance and cost estimates for the optimum field. It is also possible to optimize receiver size and tower height by a repeated application of the field optimization procedure.

  4. Atmospheric emissions control at ENELVEN`s Ramon Laguna thermal power plant; Control de emisiones a la atmosfera en la central termoelectrica Ramon Laguna de ENELVEN

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Rincon, Edis Rafael [Empresa de Servicio Electrico (ENELVEN), (Venezuela)

    1996-12-31

    ENELVEN is an electric utility that covers the areas of generation, transmission and distribution of the Western an South coast of the Maracaibo Lake of the Zulia State, Venezuela. General aspects of the Ramon Laguna of ENELVEN fossil power plant are presented, as well as the environmental measures implanted in this power station to avoid detrimental effects on the environment that could be caused by the emission of combustion products without the appropriate control, such as particulate matter, sulfur oxides, nitrogen oxides and carbon oxides [Espanol] ENELVEN es una empresa de servicio electrico que cubre las areas de generacion, transmision y distribucion de la Costa Occidental y Sur del Lago de Maracaibo, del Estado Zulia, Venezuela. Se presentan aspectos generales de la planta termoelectrica Ramon Laguna de la empresa ENELVEN, asi como las medidas ambientales implantadas en esta central para evitar efectos adversos sobre el ambiente que pudieran producirse por la emision de productos de la combustion si no existiera el debido control, tales como: particulas, oxidos de azufre, oxidos de nitrogeno y oxidos de carbono

  5. Adaptation of thermal power plants

    NARCIS (Netherlands)

    Bogmans, Christian W.J.; Dijkema, Gerard P.J.; Vliet, van Michelle T.H.

    2017-01-01

    When does climate change information lead to adaptation? We analyze thermal power plant adaptation by means of investing in water-saving (cooling) technology to prevent a decrease in plant efficiency and load reduction. A comprehensive power plant investment model, forced with downscaled climate

  6. Direct observation of 134Cs and 137Cs in surface seawater in the western and central North Pacific after the Fukushima Dai-ichi nuclear power plant accident

    Directory of Open Access Journals (Sweden)

    H. Kaeriyama

    2013-06-01

    Full Text Available The horizontal distribution of radioactive cesium (Cs derived from the Fukushima Dai-ichi nuclear power plant (FNPP in the North Pacific is still unclear due to the limitation of direct measurement of the seawater in the open ocean. We present the result of direct observation of radioactive Cs in surface seawater collected from a broad area in the western and central North Pacific in July 2011, October 2011 and July 2012. We also conducted a simple particle tracking experiment to estimate the qualitative spatial distribution of radioactive Cs in the North Pacific. 134Cs was detected at 94 stations out of 123 stations, and 137Cs was detected at all stations. High 134Cs and 137Cs concentrations more than 10 m Bq kg−1 were observed in the area of the northern part of Kuroshio Extension at 144° E and 155° E in July 2011, in the area 147–175° E around 40° N in October 2011, and the northern part of Kuroshio Extension at 155° E and 175°30´ E in July 2012. Combining the result of direct observations and particle tracking experiment, the radioactive Cs derived from the FNPP had been dispersed eastward to the central North Pacific during 2011. It was considered from the horizontal distribution that radioactive Cs was dispersed not only eastward but also north- and southward in the central North Pacific. Pronounced dilution process of radioactive Cs from the FNPP during study period is suggested from temporal change in the activity ratio of 134Cs / 137Cs, which was decay-corrected on 6 April 2011, and relationships between radioactive Cs and temperature.

  7. Direct observation of 134Cs and 137Cs in surface seawater in the western and central North Pacific after the Fukushima Dai-ichi nuclear power plant accident

    Directory of Open Access Journals (Sweden)

    S. Nakatsuka

    2013-02-01

    Full Text Available The horizontal distribution of radioactive cesium (Cs derived from the Fukushima Dai-ichi Nuclear Power Plant (FNPP in the North Pacific is still unclear due to the limitation of direct measurement of the seawater in the open ocean. We present the result of direct observation of radioactive Cs in surface seawater collected from broad area in the western and central North Pacific in July, October 2011 and July 2012. We also conducted a simple particle tracking experiment to estimate the qualitative spatial distribution of radioactive Cs in the North Pacific. 134Cs were detected at 94 stations out of 123 stations and 137Cs was detected at all stations. The high 134Cs and 137Cs concentrations more than 10 mBq kg−1 were observed in the area where the northern part of Kuroshio extension at 144° E and 155° E in July 2011, in the area 147° E–175° E around 40° N in October 2011, and the northern part of Kuroshio extension at 155° E and 175° 30´ E in July 2012. Combining the result of direct observations and particle tracking experiment, the radioactive Cs derived from FNPP had been dispersed eastward to the central North Pacific during 2011. It was considered from the horizontal distribution that radioactive Cs was dispersed not only eastward but also north- and southward in the central North Pacific. Pronounced dilution process of radioactive Cs from FNPP during study period is suggested from temporal change in the activity ratio of 134Cs/137Cs which was decay corrected at 6 April 2011, and relationships between radioactive Cs and temperature.

  8. Diffusion and dispersion heat of hydrotermal discharge from power plant; Difusion y dispersion de calor de la descarga hidrotermal de una central termoelectrica

    Energy Technology Data Exchange (ETDEWEB)

    Rendon Villalobos, J. Rodolfo

    1996-12-31

    This study describe the numerical simulation results of hydrodynamical behavior of the surface discharge cooling water to the sea incoming from the Tuxpan Power Plant under two different meteorological and oceanographic conditions; Case I, southwest variable winds average speeds of 3 m s-1 and Case II, northwest variable winds average speeds of 11.10 m s-1 . The numerical simulations were made using a three-dimensional model of coastal circulation and heat exchange. The statistical analysis of the wind speed and direction time series measured from January 1, 1981 to December 31, 1983, shows that the larger part of the winds were predominantly from 180 degrees to 315 degrees. Therefore, the southerly winds induce a sea surface circulation towards the north which move the discharged heat water away from the intake. On the contrary, the north winds drives the hydrothermal effluent towards the intake. Comparisons between the numerical simulation results and field data show that under different meteorological and oceanographic conditions, representative of the Tuxpan Site, the model correctly predicts the hydrothermal effluents surface diffusion and Dispersion measured on August 19-20 and 21, 1992 (Case I) and November 26, 1992 (Case II). The model predicts the extent of the impacted areas with cooling water with a precision of {+-} 11%. For all analyzed cases, the real size of the impacted areas that might have adverse effects on the marine ecosystems was not gibber than 0.1 km{sup 2}. Thus, these possible adverse effects are considered to be of local significance only. The simulated vertical profiles of temperature show that the cooling water discharged remains mostly o the surface of the receiving water mass and reaches a maximum depth of 3.5 m. This floatability if a consequence of the low density and small Froude number (Fr << 1), at the discharge, that characterizes the Tuxpan Power Plant Effluent. [Espanol] Este estudio describe los resultados de la simulacion

  9. Numerical evaluation of the Kalina cycle for concentrating solar power plants

    DEFF Research Database (Denmark)

    Modi, Anish

    Concentrating solar power plants use a number of reflecting mirrors to focus and convert the incident solar energy to heat, and a power cycle to convert this heat into electricity. One of the key challenges currently faced by the solar industry is the high cost of electricity production....... These costs may be driven down by developing more cost-effective plant components and improving the system designs. This thesis focuses on the power cycle aspect of the concentrating solar power plants by studying the use a Kalina cycle with ammonia-water mixtures as the cycle working fluid. The potential...... of using a Kalina cycle is evaluated with a thermoeconomic optimization with a turbine inlet temperature of 500 C for a central receiver solar power plant with direct vapour generation, and 370 C for a parabolic trough solar power plant with Therminol VP-1 as the solar field heat transfer fluid. No thermal...

  10. Gaussian mixture models as flux prediction method for central receivers

    Science.gov (United States)

    Grobler, Annemarie; Gauché, Paul; Smit, Willie

    2016-05-01

    Flux prediction methods are crucial to the design and operation of central receiver systems. Current methods such as the circular and elliptical (bivariate) Gaussian prediction methods are often used in field layout design and aiming strategies. For experimental or small central receiver systems, the flux profile of a single heliostat often deviates significantly from the circular and elliptical Gaussian models. Therefore a novel method of flux prediction was developed by incorporating the fitting of Gaussian mixture models onto flux profiles produced by flux measurement or ray tracing. A method was also developed to predict the Gaussian mixture model parameters of a single heliostat for a given time using image processing. Recording the predicted parameters in a database ensures that more accurate predictions are made in a shorter time frame.

  11. Research on Operation Security of Solar Thermal Tower Power Plant Receiver%塔式太阳能热发电吸热器运行安全性研究

    Institute of Scientific and Technical Information of China (English)

    高维; 徐蕙; 徐二树; 余强

    2013-01-01

    The Superheating cavity receiver of Badaling 1MW solar thermal power plant had produced successfully superheated steam in August 2011. Because the direct normal irradiation value is changing with time, flux density on each evaporating heating surfaces is different and Superheater has occurred deformation. According to structure of evaporating heating surfaces of Badaling 1 MW solar thermal power plant receiver, a 7-channel evaporator heating surface dynamic simulation model is developed. This model could better simulate the dynamic characteristics of receiver. Basis on the model, this paper analyzed the operation security of the overheating cavity receiver. For evaporative heating surfaces, the most dangerous working condition is a sudden increase in solar irradiance at the high load; for superheator, the most dangerous working condition is a sudden decrease in the turbine regulating valve at the high load.%八达岭1MW塔式太阳能腔式吸热器已于2011年8月成功生产出过热蒸汽.由于太阳辐照随时间变化的特点,腔式吸热器各受热面能流密度分布极不均匀.为了研究腔式吸热器的运行安全性,文中根据八达岭1MW塔式太阳能过热型腔式吸热器蒸发受热面的结构形式,建立了7通道蒸发受热面动态仿真数学模型.该模型能够反映不同蒸发受热面工质流量随能流密度变化的规律性,更好地模拟吸热器动态特性.在此基础上,通过仿真实验分析了过热型腔式吸热器运器运行安全性.对于蒸发受热面,最危险的工况是在高负荷时太阳辐照突然增强;对于过热受热面,最危险的工况是,高负荷时汽轮机调节汽门突然关小.

  12. Experiences in the computerized control rooms design for Nuclear Power Plants; Experiencias en el diseno de salas de control computarizadas para centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Moyano de la Heras, N.; Fernandez Illobre, L.; Valdivia Martin, C.

    2010-07-01

    This paper presents Tecnatom experiences obtained during the control rooms design for the Fuming and Fangjiasham Nuclear Power Plants (CPR type). These are two different locations where two pressurized water reactors, with three loops each one, will be installed.

  13. China-Central Asia Power Cooperation Outlook

    Institute of Scientific and Technical Information of China (English)

    Luo

    2010-01-01

    After analyzing the basic information,distribution of energy resources and condition of power industry in Central Asia, the high feasibility for China to cooperate closely with Central Asia in transnational power interconnection, power investment and technology exchanges, etc. is studied. Furthermore, the forms, mechanisms, existing problems and suggestions for the improvement of current policies related to the power cooperation are proposed.

  14. Engineering and maintenance applied to safety-related valves in nuclear power plants; Ingenieria y mantenimiento aplicado a valvulas relacionadas con la seguridad en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Verdu, M. F.; Perez-Aranda, J.

    2014-04-01

    Nuclear Division in Iberdrola engineering and Construction has a team with extensive experience on engineering and services works related to valves. Also, this team is linked to UNESA as Technical support and Reference Center. Iberdrola engineering and construction experience in nuclear power plants valves, gives effective response to engineering and maintenance works that can be demanded in a nuclear power plant and it requires a high degree of qualification and knowledge both in Operation and Outages. (Author)

  15. Analysis of the evolution of the collective dose in nuclear power plants in Spain; Analisis de la evolucion de la dosis colectiva en las centrales nucleares de Espana

    Energy Technology Data Exchange (ETDEWEB)

    Ponjuan Reyes, G.; Ruibia Rodiz, M. A. de la; Rosales Calvo, M.; Labarta Mancho, T.; Calavia Gimenez, I.

    2011-07-01

    This article presents an analysis of the evolution of occupational collective dose of the Spanish nuclear power plants during the period 2000 - 2008 within the international context, by the Nuclear Safety Council (CSN) in order to have information contrasted to assessing the extent of application of the ALARA criteria in the Spanish plants and identify areas of priority attention.

  16. Mobile central heating plant ensures the supply during the power-plant modernization. Planning-safe reconstruction; Mobile Heizzentrale sichert Versorgung waehrend Kraftwerksmodernisierung. Planungssicherer Umbau

    Energy Technology Data Exchange (ETDEWEB)

    Bernhard, Petra [Mobiheat GmbH, Friedberg (Germany). Presse- und Oeffentlichkeitsarbeit

    2012-09-15

    During the comprehensive energetic retrofitting of district heating plants in the spa resort of Badenweiler (Federal Republic of Germany) a mobile 2-MW heating plant from Mobilheat (Ebersberg, Federal Republic of Germany) was used for the heat supply. Thus, the installation of environmental friendly energy supply based on cogeneration plants could be implemented with planning security. This particularly was important because, among other things, the traditional spa resort, the Kurhaus as well as hotels and private customers depend on the heat supply system. These buildings have be supplied with thermal water also in the summer.

  17. Modernization of the system integrated ERIS computer (SIEC) of the nuclear power plant Cofrentes; Modernizacion del sistema integrado ERIS computador (SIEC) de la Central Nuclear de cofrentes

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, R.; Ramos, M.; Mendez, J.; Zuriaga, J. V.

    2011-07-01

    The complete replacement of the SIEC of Nuclear Power Cofrentes is framed within the process of modernization of systems instrumentation and control in which the Spanish nuclear power plants are immersed, process caused by an increase in security, as well as the obsolescence and lack of spare parts.

  18. Evaluation of the variability of wind speed at different heights and its impact on the receiver efficiency of central receiver systems

    Science.gov (United States)

    Delgado, A.; Gertig, C.; Blesa, E.; Loza, A.; Hidalgo, C.; Ron, R.

    2016-05-01

    Typical plant configurations for Central Receiver Systems (CRS) are comprised of a large field of heliostats which concentrate solar irradiation onto the receiver, which is elevated hundreds of meters above the ground. Wind speed changes with altitude above ground, impacting on the receiver thermal efficiency due to variations of the convective heat losses. In addition, the physical properties of air vary at high altitudes to a significant degree, which should be considered in the thermal losses calculation. DNV GL has long-reaching experience in wind energy assessment with reliable methodologies to reduce the uncertainty of the determination of the wind regime. As a part of this study, DNV GL estimates the wind speed at high altitude for different sites using two methods, a detailed estimation applying the best practices used in the wind energy sector based on measurements from various wind sensors and a simplified estimation applying the power law (1, 2) using only one wind measurement and a representative value for the surface roughness. As a result of the study, a comparison of the wind speed estimation considering both methods is presented and the impact on the receiver performance for the evaluated case is estimated.

  19. The positioning of Iberdrola Ingenieria y Construccion in the market for new electric power plants; Posicionamiento de Iberdrola Ingenieria y Construccion en el mercado de las nuevas centrales

    Energy Technology Data Exchange (ETDEWEB)

    Garnica, E.; Cubain, B.; Chimeno, M. A.; Ortego, A.

    2009-07-01

    IBERDROLA Ingeneria y Contruccion carrying out a wide plant of activities oriented to position the company in the emerging marketplace of new nuclear power plants whose expectation for the next years is highly promising. Obviously, the plan is focused in their technicians, which include people that are very knowledgeable and others younger, both strongly committed with the managerial project. During the las years, the gained experience in nuclear projects, together with other successfully generation projects (combined cycles gas turbine and renewable) allow warranty the success in the challenge of building new nuclear power plants for the next years. (Author)

  20. Diagnosis of feed water, condensate and circulation pumps in electric power plants; Diagnostico de bombas de agua de alimentacion, condensado y circulacion en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Colin Castellanos, Carlos [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1991-12-31

    This article encompasses the analysis and the diagnosis of the pump`s performance that belong to the feed water, condensate and circulation systems of a fossil fuel power plant (FFPP). For this analysis pressure, temperature and flow data were collected by means of field installed instrumentation, as well as these pumps` motors current consumption and voltage values. Later on, the capacity and the pump efficiency are calculated and compared with the design values, to obtain the actual performance of the equipment with the aid of their characteristic curves (Q vs {Delta}H, Q vs {pi}, etc.). [Espanol] Este articulo comprende el analisis y el diagnostico de comportamiento de las bombas, las cuales forman parte de los sistemas de agua de alimentacion, condensado y circulacion de una central termoelectrica (CT). Para el analisis se recopilan datos de presion, temperatura y flujo de la instrumentacion instalada en campo, asi como de los valores de consumo de corriente y de voltaje en los motores de dichas bombas. Posteriormente, se calcula la capacidad y la eficiencia de las bombas en operacion real y se comparan con los valores de diseno, para obtener el comportamiento real del equipo con ayuda de las curvas caracteristicas (Q vs {Delta}H, Q vs {pi}, etcetera).

  1. Training-Based SWIPT: Optimal Power Splitting at the Receiver

    OpenAIRE

    Zhou, Xiangyun

    2014-01-01

    We consider a point-to-point system with simultaneous wireless information and power transfer (SWIPT) over a block fading channel. Each transmission block consists of a training phase and a data transmission phase. Pilot symbols are transmitted during the training phase for channel estimation at the receiver. To enable SWIPT, the receiver adopts a power-splitting design, such that a portion of the received signal is used for channel estimation or data detection, while the remaining is used fo...

  2. Advance: research project on aging electrical wiring in nuclear power plants; Advance: proyecto de investigacion de envejecimiento en cableado electrico en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Cano, J. C.; Ruiz, S.

    2013-07-01

    As Nuclear Power Plants get older it is more important to know the real condition of low voltage, instrumentation, power and control cables. Additionally, as new plants are being built, the election of cables and the use of in-situ monitoring techniques to get reliable aging indicators, can be very useful during the plant life. The goal of this Project is to adapt, optimize and asses Condition Monitoring techniques for Nuclear Power Plants cables. These techniques, together with the appropriate acceptance criteria, would allow specialists to know the state of the cable over its entire length and estimate its residual life. In the Project, accelerated ageing is used in cables installed in European NPPs in order to evaluate different techniques to detect local and global ageing. Results are compared with accepted tests to validate its use for the estimation of cables residual life. This paper describes the main stages of the Project and some results. (Author)

  3. Direct steam generation (DSG) solar thermal power plant in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sukchai, Sukruedee; Chramsa-ard, Wisut; Sonsaree, Sorawit; Boonsu, Rungrudee [Naresuan Univ., Phitsanulok (Thailand). School of Renewable Energy Technology; Krueger, Joachim; Pandian, Yuvaraj [Solarlite GmbH, Duckwitz (Germany)

    2012-07-01

    In 2010, the total electricity consumption in Thailand was 149,301 GWh, increased by 10.5% compared with that in the previous year. The economic sector accounting for the highest share of national electricity consumption was the industrial sector, holding a share of 46%; while the household and commercial sectors accounted for a share of 22% and 15% respectively. The electricity is generated from natural gas, coal, oil, hydro, import and other of 72%, 18%, 0.4%, 3%, 4%, and 2% respectively. In the past, the Electricity Generating Authority of Thailand (EGAT) was the sole power producer. Later, the government had formulated a policy promoting the private sector role in the power generation sector in order to encourage competition in the generation business. Currently, it is resulting in a growing number of Very Small Power Producers (VSPP), using renewable energy as main fuel, supplying power to the grid. In this presentation, general background and situation of solar thermal power plant (DSG) in Thailand will be presented. The resource potential which presented by solar map for the central, north and northeast parts of the country is quite clear sky that receive the highest direct normal irradiation of 1,350 - 1,400 kWh/m{sup 2}-year stand for 43% of the total areas of the country. Together with the high direct normal irradiation is received during summer from January to April about 14-17 MJ/m{sup 2}-day. The first of solar thermal power plant in Thailand is presented. Solar energy development that is one of renewable energy promotion program in the nation master plan has been reviewed and discussed to indicate the recommendation. Barriers as educational, technical and financial to promote solar thermal power plant is also presented. From the investigation, this presentation proposes some idea to be the guideline for policy setting, overcome the solar thermal power plant barrier in Thailand. (orig.)

  4. Effect of High Receiver Thermal Loss Per Unit Area on the Performance of Solar Central Receiver Systems Having Optimum Heliostat Fields and Optimum Receiver Aperture Areas.

    Science.gov (United States)

    Pitman, Charles L.

    Recent efforts in solar central receiver research have been directed toward high temperature applications. Associated with high temperature processes are greater receiver thermal losses due to reradiation and convection. This dissertation examines the performance of central receiver systems having optimum heliostate fields and receiver aperture areas as a function of receiver thermal loss per unit area of receiver aperture. The results address the problem of application optimization (loss varies) as opposed to the problem of optimization of a design for a specific application (loss fixed). A reasonable range of values for the primary independent variable L (the average reradiative and convective loss per unit area of receiver aperture) and a reasonable set of design assumptions were first established. The optimum receiver aperture area, number and spacings of heliostats, and field boundary were then determined for two tower focal heights and for each value of L. From this, the solar subsystem performance for each optimized system was calculated. Heliostat field analysis and optimization required a detailed computational analysis. A significant modification to the standard method of solving the optimization equations, effectively a decoupling of the solution process into collector and receiver subsystem parts, greatly aided the analysis. Results are presented for tower focal heights of 150 and 180 m. Values of L ranging from 0.04 to 0.50 MW m('-2) were considered, roughly corresponding to working fluid temperatures (at receiver exit) in the range of 650 to 1650 C. As L increases over this range, the receiver thermal efficiency and the receiver interception factor decrease. The optimal power level drops by almost half, and the cost per unit of energy produced increases by about 25% for the base case set of design assumptions. The resulting decrease in solar subsystem efficiency (relative to the defined annual input energy) from 0.57 to 0.35 is about 40% and is a

  5. PERFORMANCE COMPARRIONS OF SOLAR CENTRAL RECEIVERS AND WORKING FLUIDS FOR SOLAR POWER TOWER SYSTEMS%塔式太阳能热发电吸热器性能及工作介质的比较研究

    Institute of Scientific and Technical Information of China (English)

    杨敏林; 杨晓西; 张珊珊

    2008-01-01

    In this paper,comparisons of different receivers were made on the performance of solar power tower systems. Cavity receiver features higher heat efficiency than external receiver but has drawback in economic performance. Direct absorption receiver is obviously superior to indirect absorption receiver by reducing start-up losses,lowering thermal losses and improving absorptance. As the heat transfer fluid,molten salt has higher thermal capacity and better performance in economic and safety aspects,but the receiver needs accurate heliostat tracking and its working temperature is restrictedly restrained. On the contrary,air has no limitations on the working temperature and is quite friendly to the environment. But it has small thermal capacity,which leads to a reduction in the economic capability.Water/steam receiver has good features in efficiency and thermal capacity but the piping and vessels need to tolerate high pressure.%比较了各种吸热器在塔式太阳能系统中的表现,结果发现腔式吸热器比外热式吸热器具有更高的吸热效率,但经济性略差;在工作介质方面,熔盐介质具有热容量大及经济性、安全性较好的优点,但工作温度受限,对反射镜的控制精度要求高;而空气没有温度限制,并且对环境友好,但其热容量较小,导致经济性不好;水/蒸汽式吸热器有较高的效率及热容量,但管路及容器等需承受高压.

  6. Questions to the reactors power upgrade of the Nuclear Power Plant of Laguna Verde; Cuestionamientos al aumento de potencia de los reactores de la Central Nuclear de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Salas M, B., E-mail: salasmarb@yahoo.com.mx [UNAM, Facultad de Ciencias, Departamento de Fisica, Circuito exterior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2014-08-15

    The two reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) were subjected to power upgrade labors with the purpose of achieving 20% upgrade on the original power; these labors concluded in August 24, 2010 for the Reactor 1 and in January 16, 2011 for the Reactor 2, however in January of 2014, the NNP-L V has not received by part of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) the new Operation License to be able to work with the new power, because it does not fulfill all the necessary requirements of safety. In this work is presented and analyzed the information obtained in this respect, with data provided by the Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) and the Comision Federal de Electricidad (CFE) in Mexico, as well as the opinion of some workers of the NPP-L V. The Governing Board of the CFE announcement that will give special continuation to the behavior on the operation and reliability of the NPP-L V, because the frequency of not announced interruptions was increased 7 times more in the last three years. (Author)

  7. Evaluation of solar-air-heating central-receiver concepts

    Energy Technology Data Exchange (ETDEWEB)

    Bird, S.P.; Drost, M.K.; Williams, T.A.; Brown, D.R.; Fort, J.A.; Garrett-Price, B.A.; Hauser, S.G.; McLean, M.A.; Paluszek, A.M.; Young, J.K.

    1982-06-01

    The potential of seven proposed air-heating central receiver concepts are evaluated based on an independent, uniform of each one's performance and cost. The concepts include: metal tubes, ceramic tubes, sodium heat pipes, ceramic matrix, ceramic domes, small particles, and volumetric heat exchange. The selection of design points considered in the analysis, the method and ground rules used in formulating the conceptual designs are discussed, and each concept design is briefly described. The method, ground rules, and models used in the performance evaluation and cost analysis and the results are presented. (LEW)

  8. AND THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alduhov Oleg Aleksandrovich

    2012-10-01

    Full Text Available Investigation of the atmospheric dispersion as part of the process of selection of sites to accommodate nuclear and thermal power plants is performed to identify concentration fields of emissions and to assess the anthropogenic impact produced on the landscape components and human beings. Scattering properties of the atmospheric boundary layer are mainly determined by the turbulence intensity and the wind field. In its turn, the turbulence intensity is associated with the thermal stratification of the boundary layer. Therefore, research of the atmospheric dispersion is reduced to the study of temperature and wind patterns of the boundary layer. Statistical processing and analysis of the upper-air data involves the input of the data collected by upper-air stations. Until recently, the upper-air data covering the standard period between 1961 and 1970 were applied for these purposes, although these data cannot assure sufficient reliability of assessments in terms of the properties of the atmospheric dispersion. However, recent scientific and technological developments make it possible to substantially increase the data coverage by adding the upper-air data collected within the period between 1964 and 2010. The article has a brief overview of BL_PROGS, a specialized software package designated for the processing of the above data. The software package analyzes the principal properties of the atmospheric dispersion. The use of the proposed software package requires preliminary development of a database that has the information collected by an upper-air station. The software package is noteworthy for the absence of any substantial limitations imposed onto the amount of the input data that may go up in proportion to the amount of the upper-air data collected by upper-air stations.

  9. Simulating solar power plant variability :

    Energy Technology Data Exchange (ETDEWEB)

    Lave, Matthew Samuel; Ellis, Abraham; Stein, Joshua.

    2013-06-01

    It is important to be able to accurately simulate the variability of solar PV power plants for grid integration studies. We aim to inform integration studies of the ease of implementation and application-specific accuracy of current PV power plant output simulation methods. This report reviews methods for producing simulated high-resolution (sub-hour or even sub-minute) PV power plant output profiles for variability studies and describes their implementation. Two steps are involved in the simulations: estimation of average irradiance over the footprint of a PV plant and conversion of average irradiance to plant power output. Six models are described for simulating plant-average irradiance based on inputs of ground-measured irradiance, satellite-derived irradiance, or proxy plant measurements. The steps for converting plant-average irradiance to plant power output are detailed to understand the contributions to plant variability. A forthcoming report will quantify the accuracy of each method using application-specific validation metrics.

  10. Multi-objective thermoeconomic optimisation of solar thermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Favrat, D.; Allani, Y.; Kane, M.; Pelet, X.; Juchli, I.; Hongli Zhang; Augsburger, G.; Sanchez, M.; Romero, M.

    2008-07-01

    This set of presentation slides was presented by the Swiss Federal Institute of Technology (EPFL) in Lausanne, Switzerland, at a conference on concentrated solar power held at the Swiss Centre for Electronics and Microtechnology in Neuchatel in 2008. The slides take a look at various central receiver systems and their associated heliostat fields and trough collectors. The thermo-economic optimisation of such plants is examined and the use of multi-objective optimisation is discussed. The use of this algorithm in the design of heliostat fields is examined and examples are given of efforts to optimise specific energy costs and investments.

  11. The Marstal Central Solar Heating Plant

    DEFF Research Database (Denmark)

    Heller, Alfred; Jochen, Dahm

    1999-01-01

    The central solar heating plant in Marstal is running since 1996 and has been monitored since. The resulting data from the plant is analysed and the plant performance evaluated. A TRNSYS-model (computersimulation) id prepared and validated based on the measured data from the plant. Acceptable good...

  12. Comparative Performance Assessment For Central Receiver CPV Systems

    Science.gov (United States)

    Lasich, John B.; Thomas, Ian; Verlinden, Pierre J.; Lewandowski, Allan; Heartag, Wolfgang; Wright, Mark

    2011-12-01

    A Central receiver Concentrating PV (C2PV) system has the potential to be the optimum solar energy generation system for utility scale because it combines the high efficiency of CPV with the low cost of a heliostat collector. Due to the off axis nature of a heliostat central receiver concentrator a cosine efficiency loss is incurred and, unlike `normal' tracking CPV lens and dish systems, the optical performance varies with time and site latitude. To investigate the optical performance of a C2PV system a ray trace model has been developed and the performance of a representative C2PV system is modelled throughout the year and at different site latitudes. The cosine loss and latitude dependence are put into perspective by calculating the annual average optical efficiency and testing its sensitivity to variations in site latitude. These values are then used to estimate a system performance by applying efficiencies for solar cell, balance of system and operational factors. This system efficiency is finally compared to published data for `normal' tracking CPV dish and lens systems. Modelled annual average AC system efficiency for the C2PV system was calculated to be 21% at 40° latitude and 19% at 15° latitude. These annual average AC system efficiencies are shown to be similar to those reported for typical dish and lens CPV systems when they are adjusted to use a total collector area baseline.

  13. Risks and challenges associated with the design and construction of a nuclear power plant; Control de riesgos y retos asociados al diseno y construccion de una central nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Liebana Martinez, B.; Armas Garcia, A.; Martinez Gozalo, I.

    2011-07-01

    The construction of a nuclear power plant project, considering the period prior to the operation of the plant, requires a very strict risk control to ensure compliance with a series of challenges. The present paper identifying the most important challenges facing the construct ability and license requirements of the process, identifying the interfaces and proposing a methodology of construction to meet the challenge of a construction process in 5 years.

  14. Nuclear emergency buildings of Asco and Vandellos II nuclear power plants; Centros alternativos de emergencias de las centrales nucleares de Asco y Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    Massuet, J.; Sabater, J.; Mirallas Esteban, S.

    2016-08-01

    The Nuclear Emergency Buildings sited at Asco and Vandellos II Nuclear Power Plants (NPP) are designed to safety manage emergencies in extreme situations, beyond the design basis of the Nuclear Power Plants. Designed in accordance with the requirements of the Spanish Nuclear Regulator (Consejo de Seguridad Nuclear-CSN) these buildings are ready to operate over a period of 72 hours without external assistance and ensure habitability for crews of 120 and 70 people respectively. This article describes the architectural conception, features and major systems of the Nuclear Emergency Buildings sited at Asco and Vandellos II. (Author)

  15. The modernization of the process computer of the Trillo Nuclear Power Plant; Modernizacion del ordenador de proceso de la Central Nuclear de Trillo

    Energy Technology Data Exchange (ETDEWEB)

    Martin Aparicio, J.; Atanasio, J.

    2011-07-01

    The paper describes the modernization of the Process computer of the Trillo Nuclear Power Plant. The process computer functions, have been incorporated in the non Safety I and C platform selected in Trillo NPP: the Siemens SPPA-T2000 OM690 (formerly known as Teleperm XP). The upgrade of the Human Machine Interface of the control room has been included in the project. The modernization project has followed the same development process used in the upgrade of the process computer of PWR German nuclear power plants. (Author)

  16. Solar thermal electric power plants - Their performance characteristics and total social costs

    Science.gov (United States)

    Caputo, R. S.; Truscello, V. C.

    1976-01-01

    The central receiver (power tower) concept as a thermal conversion approach to the conversion of solar energy into electricity is compared to other solar power plant designs which feature distributed solar collection and use other types of solar collector configurations. A variety of solar thermal storage concepts are discussed and their impacts on system performance are assessed. Although a good deal of quantification is possible in a comparative study, the subjective judgments carry enormous weight in a socio-economic decision, the ultimate choice of central power plant being more a social than an economic or technical decision. Major elements of the total social cost of each type of central plant are identified as utility economic costs, R&D funds, health costs, and other relevant social impacts.

  17. Cesium-134 and 137 activities in the central North Pacific Ocean after the Fukushima Dai-ichi nuclear power plant accident

    Directory of Open Access Journals (Sweden)

    J. Kameník

    2013-03-01

    Full Text Available Surface seawater 134Cs and 137Cs samples were collected in the central and western North Pacific Ocean during the 1.5 yr after the Fukushima Dai-ichi nuclear power plant accident to monitor dispersion patterns of these radioisotopes towards the Hawaiian Islands. In the absence of other recent sources and due to its short half-life only those parts of the Pacific Ocean would have detectable 134Cs that were impacted by Fukushima releases. Between March and May 2011, 134Cs was not detected around the Hawaiian Islands and Guam. Here, most 137Cs activities (1.2–1.5 Bq m−3 were in the range of expected preexisting levels. Some samples north of the Hawaiian Islands (1.6–1.8 Bq m−3 were elevated above the 18-month baseline established in surface seawater in Hawaii indicating that those might carry atmospheric fallout. The 18-month time-series analysis of surface seawater from Hawaii did not reveal any seasonal variability or trends, with an average activity of 1.46 ± 0.06 Bq m−3 (Station Aloha, 17 values. In contrast, samples collected between Japan and Hawaii contained 134Cs activities in the range of 1–4 Bq m−3 and 137Cs levels were about 2–3 times above the preexisting activities. We found that the southern boundary of the Kuroshio and Kuroshio extension currents represented a boundary for radiation dispersion with higher activities detected within and north of the major currents. The radiation plume has not been detected over the past 1.5 yr at the main Hawaiian Islands due to the transport patterns across the Kuroshio and Kuroshio extension currents.

  18. Cesium-134 and 137 activities in the central North Pacific Ocean after the Fukushima Dai-ichi Nuclear Power Plant accident

    Directory of Open Access Journals (Sweden)

    J. Kameník

    2013-09-01

    Full Text Available Surface seawater 134Cs and 137Cs samples were collected in the central and western North Pacific Ocean during the 2 yr after the Fukushima Dai-ichi Nuclear Power Plant accident to monitor dispersion patterns of these radioisotopes towards the Hawaiian Islands. In the absence of other recent sources and due to its short half-life, only those parts of the Pacific Ocean would have detectable 134Cs values that were impacted by Fukushima releases. Between March and May 2011, 134Cs was not detected around the Hawaiian Islands and Guam. Here, most 137Cs activities (1.2–1.5 Bq m–3 were in the range of expected preexisting levels. Some samples north of the Hawaiian Islands (1.6–1.8 Bq m–3 were elevated above the 23-month baseline established in surface seawater in Hawaii indicating that those might carry atmospheric fallout. The 23-month time-series analysis of surface seawater from Hawaii did not reveal any seasonal variability or trends, with an average activity of 1.46 ± 0.06 Bq m–3 (Station Aloha, 18 values. In contrast, samples collected between Japan and Hawaii contained 134Cs activities in the range of 1–4 Bq m–3, and 137Cs levels were about 2–3 times above the preexisting activities. We found that the southern boundary of the Kuroshio and Kuroshio extension currents represented a boundary for radiation dispersion with higher activities detected within and north of the major currents. The radiation plume has not been detected over the past 2 yr at the main Hawaiian Islands due to the transport patterns across the Kuroshio and Kuroshio extension currents.

  19. Cesium-134 and 137 activities in the central North Pacific Ocean after the Fukushima Dai-ichi Nuclear Power Plant accident

    Science.gov (United States)

    Kameník, J.; Dulaiova, H.; Buesseler, K. O.; Pike, S. M.; Št'astná, K.

    2013-09-01

    Surface seawater 134Cs and 137Cs samples were collected in the central and western North Pacific Ocean during the 2 yr after the Fukushima Dai-ichi Nuclear Power Plant accident to monitor dispersion patterns of these radioisotopes towards the Hawaiian Islands. In the absence of other recent sources and due to its short half-life, only those parts of the Pacific Ocean would have detectable 134Cs values that were impacted by Fukushima releases. Between March and May 2011, 134Cs was not detected around the Hawaiian Islands and Guam. Here, most 137Cs activities (1.2-1.5 Bq m-3) were in the range of expected preexisting levels. Some samples north of the Hawaiian Islands (1.6-1.8 Bq m-3) were elevated above the 23-month baseline established in surface seawater in Hawaii indicating that those might carry atmospheric fallout. The 23-month time-series analysis of surface seawater from Hawaii did not reveal any seasonal variability or trends, with an average activity of 1.46 ± 0.06 Bq m-3 (Station Aloha, 18 values). In contrast, samples collected between Japan and Hawaii contained 134Cs activities in the range of 1-4 Bq m-3, and 137Cs levels were about 2-3 times above the preexisting activities. We found that the southern boundary of the Kuroshio and Kuroshio extension currents represented a boundary for radiation dispersion with higher activities detected within and north of the major currents. The radiation plume has not been detected over the past 2 yr at the main Hawaiian Islands due to the transport patterns across the Kuroshio and Kuroshio extension currents.

  20. Asbury power plant, Asbury, Missouri

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, K.

    2005-08-01

    The Asbury power plant in rural southwest Missouri is off the beaten path in more ways than one. Three years ago, Empire District Electric Co., the plant's owner/operator, began mixing pieces of discarded tires into its coal fuel supply. Each ensuing year, without compromising local air quality, the plant has rid the area of millions of tires that otherwise would have ended up in a landfill. For demonstrating that a blight can be made right, Asbury is one of Power's 2005 top plants. 2 figs., 1 tab.

  1. Development of a solar thermal central heat receiver using molten salt

    Science.gov (United States)

    Tracey, T. R.

    1981-06-01

    The development and test of a 5 MWth solar heat receiver using a molten nitrate salt (60 percent NaNO3, 40 percent KNaNO3) as the heat transfer fluid is described. The application of the receiver concept in a central receiver solar power system is explained. The advantages of using molten nitrate salts as the receiver heat transfer fluid and the storage fluid are discussed. The problems associated with the receiver development including the need for high temperatures and combinations of creep and fatigue in the receiver tubes are discussed. Our approach to scaling from the 5 MWth test receiver to commercial receivers in the range of 200 MWth to 500 MWth is defined. The 5 MWth test system is described including the instrumentation used. The test facility which has a 60 m tower and 222 heliostats is described. The test results are presented. The receiver was in test for 500 hr at temperature and heat flux levels expected in commercial receiver systems.

  2. Monitoring systems online of oil for transformers of nuclear power plants; Sistemas de monitorizacion online del aceite para transformadores de potencia de Centrales

    Energy Technology Data Exchange (ETDEWEB)

    Sarandeses, S.

    2014-07-01

    The nuclear power plants are showing their concern due to the existence of recent failures related to the bulky transformers of power. These transformers are not security, but are important for the production of power as its failure can cause transient on the floor, reactor scram or shooting, that can cause interruptions in the production of energy or might force us to reduce the power of production The analysis of gases dissolved in transformer oil is recognized as a trial key to identify a submerged transformer failure in oil. With this analysis it is not possible to ensure that there is no damage in the transformer, but the probability of risk of this type of failure can be reduced. The industry recommended to equip the new large power transformers with oil online monitoring systems and in some cases also be It recommended its use in existing transformers. (Author)

  3. Power Plant Water Intake Assessment.

    Science.gov (United States)

    Zeitoun, Ibrahim H.; And Others

    1980-01-01

    In order to adequately assess the impact of power plant cooling water intake on an aquatic ecosystem, total ecosystem effects must be considered, rather than merely numbers of impinged or entrained organisms. (Author/RE)

  4. Nuclear Power Plant Simulation Game.

    Science.gov (United States)

    Weiss, Fran

    1979-01-01

    Presents a nuclear power plant simulation game which is designed to involve a class of 30 junior or senior high school students. Scientific, ecological, and social issues covered in the game are also presented. (HM)

  5. Design of photovoltaic central power station concentrator array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using tracking concentrators has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes an advanced Martin Marietta two-axis tracking fresnel lens concentrator. The concentrators are arrayed in 5 MW subfields, each with its own power conditioning unit. The photovoltaic plant output is connected to the existing 115 kV switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  6. Fukushima, two years later, modification requirements in nuclear power plants; Fukushima, dos anos despues, requerimientos de modificacion en centrales nucleares de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez J, J.; Camargo C, R.; Nunez C, A.; Mendoza F, J. E.; Salmeron V, J. A., E-mail: jerson.sanchez@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    The occurred events in the nuclear power plant of Fukushima Daiichi as consequence of the strong earthquake of 9 grades in the Richter scale and the later tsunami with waves estimated in more than 14 meters high began a series of important questions about the safety of the nuclear power plants in operation and of the new designs. Firstly, have allowed to be questioned on the magnitudes and consequences of the extreme external natural events; that can put in risk the integrity of the safety barriers of a nuclear power plant when being presented in a multiple way. As consequence of the events of the Fukushima Daiichi NPP, the countries with NPPs in operation and /or construction carried out evaluations about their safety operation. They have also realized evaluations about accidents and their impact in the safety, analysis and studies too that have forced to the regulatory bodies to continue a systematic and methodical revision of their procedures and regulations, to identify the possible improvements to the safety in response to the events happened in Japan; everything has taken it to determine the necessity to incorporate additional requirements to the nuclear power plants to mitigate events Beyond the Design Base. Due to Mexico has the nuclear power plant of Laguna Verde, with two units of BWR-5 type with contention Mark III, some the modifications can be applicable to these units to administrate and/or to mitigate the consequences of the possible occurrence of an accident Beyond the Design Base and that could generate a severe accident. In this work an exposition is presented on the modification requirements to confront external natural events Beyond the Design Base, and its application in our country. (Author)

  7. Study of CO{sub 2} capture processes in power plants; Etude de procedes de captage du CO{sub 2} dans les centrales thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.M

    2007-12-15

    The aim of the present study is to assess and compare various processes aiming at recover CO{sub 2} from power plants fed with natural gas (NGCC) and pulverized coal (PC). These processes are post-combustion CO{sub 2} capture using chemical solvents, natural gas reforming for pre-combustion capture by methanol and oxy-fuel combustion with cryogenic recovery of CO{sub 2}. These processes were evaluated using the process software Aspen PlusTM to give some clues for choosing the best option for each type of power plant. With regard to post-combustion, an aqueous solution based on a mixture of amines (N-methyldiethanolamine (MDEA) and triethylene tetramine (TETA)) was developed. Measurements of absorption were carried out between 298 and 333 K in a Lewis cell. CO{sub 2} partial pressure at equilibrium, characteristic of the CO{sub 2} solubility in the solvent, was determined up to 393 K. The solvent performances were compared with respect to more conventional solvents such as MDEA and monoethanolamine (MEA). For oxy-fuel combustion, a recovery process, based on a cryogenic separation of the components of the flue gas, was developed and applied to power plants. The study showed that O{sub 2} purity acts on the CO{sub 2} concentration in the flue gas and thus on the performances of the recovery process. The last option is natural gas reforming with CO{sub 2} pre-combustion capture. Several configurations were assessed: air reforming and oxygen reforming, reforming pressure and dilution of the synthesis gas. The comparison of these various concepts suggests that, in the short and medium term, chemical absorption is the most interesting process for NGCC power plants. For CP power plants, oxy-combustion can be a very interesting option, as well as post-combustion capture by chemical solvents. (author)

  8. Evaluation of Veda, Inc. , central receiver solar collection system concept

    Energy Technology Data Exchange (ETDEWEB)

    Ator, J.

    1981-08-01

    The Unified Heliostat Array (UHA) is a geometrical heliostat field layout with rows of mirrors placed at various levels on terraces. The Veda Industrial Heliostat (VIH) is a toroidal segment mirror mounted on an equatorial mount. These two concepts are evaluated to assess the credibility of the optical designs and the validity of UHA and VIH performance estimates, to determine what the distinctive features embodied in UHA AND VIH concepts offer that more conventional central receiver technologies do not, and to determine where the UHA and VIH concepts might be most applicable in DOE's Solar Thermal Program. The UHA area efficiency, flux density distribution, and beam safety are evaluated, and the feasibility of using a secondary mirror and the potential for special applications are assessed. The optical design, equatorial mount, and manufacturability of the VIH are evaluated. (LEW)

  9. Nuclear power plants of ENDESA: strategical and operational fields. Research and Development. Centrales Nucleares de ENDESA Campos de actuacion estrategica y operativa. Investigacion y desarrollo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, E. (Empresa Nacional de Electricidad. ENDESA. (Spain))

    1994-01-01

    The total nuclear power installed at ENDESA plants amounts 1467 Mw. Environmental management is focused onto waste management, emissions management and safety during operation. The strategy of ENDESA is related with actions to improve research and development in advanced power reactors and passive power plants like AP-600 and SBWR. There is also a collaboration with EPRI to define the specifications for future reactors. ENDESA participates within the European NPI program for evolutive reactors to develop the French EPRI reactor. R+D in materials is organized in: steam generators projects, analysis of neutronic irradiation of the vessel in Light Water Reactors, analysis of cladding and fuel rods subjected to high burning, inspection of cracks in vessel PWR.

  10. Life time of nuclear power plants and new types of reactors; La duree de vie des centrales nucleaires et les nouveaux types de reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-01

    This report, realized by the Evaluation Parliamentary Office of scientific and technological choices, aims to answer simple but fundamental questions for the french electric power production. What are the phenomena which may limit the exploitation time of nuclear power plants? How can we fight against the aging, at which cost and with which safety? The first chapter presents the management of the nuclear power plants life time, an essential element of the park optimization but not a sufficient element. The second chapter details the EPR and the other reactors for 2015 as a bond between the today and tomorrow parks. The last chapter deals with the necessity of efforts in the research and development to succeed in 2035 and presents other reactors in project. (A.L.B.)

  11. Central Andean crustal structure from receiver function analysis

    Science.gov (United States)

    Ryan, Jamie; Beck, Susan; Zandt, George; Wagner, Lara; Minaya, Estela; Tavera, Hernado

    2016-07-01

    The Central Andean Plateau (15°-27°S) is a high plateau in excess of 3 km elevation, associated with thickened crust along the western edge of the South America plate, in the convergent margin between the subducting Nazca plate and the Brazilian craton. We have calculated receiver functions using seismic data from a recent portable deployment of broadband seismometers in the Bolivian orocline (12°-21°S) region and combined them with waveforms from 38 other stations in the region to investigate crustal thickness and crust and mantle structures. Results from the receiver functions provide a more detailed map of crustal thickness than previously existed, and highlight mid-crustal features that match well with prior studies. The active volcanic arc and Altiplano have thick crust with Moho depths increasing from the central Altiplano (65 km) to the northern Altiplano (75 km). The Eastern Cordillera shows large along strike variations in crustal thickness. Along a densely sampled SW-NE profile through the Bolivian orocline there is a small region of thin crust beneath the high peaks of the Cordillera Real where the average elevations are near 4 km, and the Moho depth varies from 55 to 60 km, implying the crust is undercompensated by 5 km. In comparison, a broader region of high elevations in the Eastern Cordillera to the southeast near 20°S has a deeper Moho at 65-70 km and appears close to isostatic equilibrium at the Moho. Assuming the modern-day pattern of high precipitation on the flanks of the Andean plateau has existed since the late Miocene, we suggest that climate induced exhumation can explain some of the variations in present day crustal structure across the Bolivian orocline. We also suggest that south of the orocline at 20°S, the thicker and isostatically compensated crust is due to the absence of erosional exhumation and the occurrence of lithospheric delamination.

  12. Economic sensitivity analysis applied to a biomass micro thermoelectric power plant, with 300 kW installed power; Analise de sensibilidade economica aplicada a uma micro central termeletrica a biomassa, com potencia instalada de 300 kW

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Flavio Dias; Gallon, Roger; Serafini, Seimur; Hoffmann, Ronaldo [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Centro de Tecnologia], e-mail: flaviodmayer@yahoo.com.br

    2008-07-01

    The simulation of a 300 k W thermoelectric biomass micro power plant demonstrated that, for the present economical situation, there no exist financial attractiveness for the investment. A government incentive program promoting a lower interest rate for the financing and/or a higher price for commercialization of surplus electric power, can be an incentive for the installation of small electric power plants, particularly at the rice sector of Rio Grande do Sul state.

  13. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  14. 76 FR 77963 - Oglethorpe Power Corporation; Proposed Biomass Power Plant

    Science.gov (United States)

    2011-12-15

    ...; ] DEPARTMENT OF AGRICULTURE Rural Utilities Service Oglethorpe Power Corporation; Proposed Biomass Power Plant... (Oglethorpe) for the construction of a 100 megawatt (MW) biomass plant and related facilities (Proposal)...

  15. Operate a Nuclear Power Plant.

    Science.gov (United States)

    Frimpter, Bonnie J.; And Others

    1983-01-01

    Describes classroom use of a computer program originally published in Creative Computing magazine. "The Nuclear Power Plant" (runs on Apple II with 48K memory) simulates the operating of a nuclear generating station, requiring students to make decisions as they assume the task of managing the plant. (JN)

  16. Communication and surrounding of Asco and Vandellos II nuclear power plants; La comunicacion y el entorno de las centrales de Asco y Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The Asco and Vandellos-II power plants have always been integrated into the regions where they are located, and they take an active part in the development of surrounding towns through quality employment provided by our facilities, social and cultural support and aid to development promoted by regional councils. Communication to media is a corporate priority defined in our strategic plant, to ensure openness, rigour and punctuality. We also attend to the visitors who want to learn more about our facilities in the visitor center, and we have agreements with agrarian institutions in the area so that students can de practical training in the farms we own for agricultural production. (Author)

  17. Development of the process of energy transfer from a nuclear Power Plant to an intermediate temperature electrolyse; Desarrollo del proceso de transferencia de energia desde una central nuclear a un electrolizador de temperatura intermedia

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Cervantes, A.; Cuadrado Garcia, P.; Soraino Garcia, J.

    2013-07-01

    Fifty million tons of hydrogen are consumed annually in the world in various industrial processes. Among them, the ammonia production, oil refining and the production of methanol. One of the methods to produce it is the electrolysis of water, oxygen and hydrogen. This process needs electricity and steam which a central nuclear It can be your source; Hence the importance of developing the transfer process energy between the two. The objective of the study is to characterize the process of thermal energy transfer from a nuclear power plant to an electrolyzer of intermediate temperature (ITSE) already defined. The study is limited to the intermediate engineering process, from the central to the cell.

  18. Conditions of call for tenders on the offshore wind power plants; Conditions de l'appel d'offres portant sur des centrales eolienne en mer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    In the framework of the renewable energies sources development, the french government decided to launch a call for tenders for the realization of offshore wind power plants in 2007. The call for tenders conditions concern: the energetic and technical characteristics of the installations as the primary energy, the production technic, the power; the industrial implementing delay; the exploitation and the operating time; the implementing sites; the weighting and the classification principles. The main conditions concerning the utilization of the maritime public land property outside of the harbors. (A.L.B.)

  19. Hybrid power plants; Thermische Hybridkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Tuschy, I. [ALSTOM Power Support, Mannheim (Germany). Bereiche Forschung und Entwicklung/Ingenieurdienstleistungen; Franke, U. [Fachhochschule Flensburg (Germany). Thermodynamik

    2002-07-01

    New German laws concerning the use of biomass and other renewable energy sources have improved the conditions for power generation with renewable energies. A promising alternative to common small-scale (combined-heat-and-) power plants could be found in so-called hybrid power plants which use renewable energies and fossil fuels in combination. A thermodynamic process analysis shows how to determine the renewable energies' portion of a hybrid power plant's total output. [German] Mit den veraenderten gesetzlichen Rahmenbedingungen erhoeht sich die Motivation, regenerative Energiequellen zur Stromerzeugung zu nutzen. Neben dem exklusiven Einsatz in kleineren (Heiz-) Kraftwerken bietet sich die gemeinsame Nutzung mit fossilen Energietraegern in sogenannten Hybridkraftwerken an. Hier stellt sich die Frage, wie der Anteil der regenerativen Energien an der Gesamt-Stromproduktion des Hybridkraftwerkes zu ermitteln ist. Eine thermodynamische Prozessanalyse kann darueber Aufschluss geben.

  20. The Biogas from bio-energy electrical power plant of Nuevo Leon; Central electrica de biogas de bioenergia de Nuevo Leon

    Energy Technology Data Exchange (ETDEWEB)

    Arvizu F, Jose L [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Saldana M, Jaime L [Sistemas de Energia Internacional S.A. de C.V. (Mexico)

    2005-07-01

    The biogas from bio-energy electrical power plant of Nuevo Leon represents, in all the national territory, the first experience on the advantage of biogas emitted by the sanitary landfills for the generation of electrical energy. Therefore, one of the specific objectives of this paper is the one of diffusion and reproduction of the same one in other cities of Mexico and Latin America. The project is framed within the world-wide policies on the control of emissions for the reduction of the greenhouse effect gases (GEG) and its impact in the global climatic change. The gas emitted by the trash sanitary landfills, commonly known as biogas, is a gas mixture derived from the decomposition of the organic matter of the municipal trash by microorganisms in anaerobic conditions. Biogas generated in the sanitary landfills has a methane content of 55% and a 35% of carbon dioxide. The balance 10% is made up of water steam, hydrogen, nitrogen, oxygen, hydrogen sulfur and other gases in minimum amounts. [Spanish] La Central Electrica de Biogas de Bioenergia de Nuevo Leon representa, en todo el territorio nacional, la primera experiencia sobre el aprovechamiento del biogas emitido por los rellenos sanitarios para la generacion de energia electrica. Por esta razon, uno de los objetivos especificos de este trabajo es la de difusion y reproduccion del mismo en otras ciudades de Mexico y Latinoamerica. El proyecto esta enmarcado dentro de las politicas mundiales sobre el control de emisiones para la reduccion de los gases de efecto invernadero (GEI) y su impacto en el cambio climatico global. El gas emitido por la basura dispuesta en los rellenos sanitarios, comunmente conocido como biogas, es una mezcla de gases derivado de la descompensacion de la materia organica de la basura municipal por microorganismos en condiciones anaerobias. El biogas generado en los rellenos sanitarios tiene un contenido de metano del 55% y un 35% de bioxido de carbono. El 10% restante se compone de vapor

  1. Establishment and evolution of Radiological Environmental Monitoring Programmes in nuclear power plants; Establecimiento y evolucion de los programas de vigilancia radiologica ambiental en las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Marugan, I.; Luque, S.; Martin, J. L.; Rey, C.; Salas, R.; Sterling, A.; Ramos, L. M.

    2013-09-01

    This article presents a brief overview of how the Radiological Environmental Monitoring Programmes carried out around nuclear power plants have evolved associated to different reasons as the legal framework, operational phases of the facilities, development on the detection and measurement of low levels of radiation due to the state of art and best available technologies, changes within sites as well as in their surroundings and accident taken place inside and outside of our borders. (Author)

  2. Implementation of the project of equipment reliability in the nuclear power plant of Laguna Verde; Implementacion del proyecto de confiabilidad de equipo en la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rios O, J. E.; Martinez L, A. G. [CFE, Central Laguna Verde, Subgerencia General de Operacion, Veracruz (Mexico)]. e-mail: jrios@cfe.gob.mx

    2008-07-01

    A equipment is reliable if it fulfills the function for which was designed and when it is required. To implement a project of reliability in a nuclear power plant this associate to a process of continuous analysis of the operation, of the conditions and faults of the equipment. The analysis of the operation of a system, of the equipment of the same faults and the parts that integrate to equipment take to identify the potential causes of faults. The predictive analysis on components and equipment allow to rectify and to establish guides to optimize the maintenance and to guarantee the reliability and function of the same ones. The reliability in the equipment is without place to doubts a wide project that embraces from the more small component of the equipment going by the proof of the parts of reserve, the operation conditions until the operative techniques of analysis. Without place of doubt for a nuclear power plant the taking of decisions based on the reliability of their systems and equipment will be the appropriate for to assure the operation and reliability of the same one. In this work would appear the project of reliability its processes, criteria, indicators action of improvement and the interaction of the different disciplines from the Nuclear Power Plant of Laguna Verde like a fundamental point for it put in operation. (Author)

  3. The continuous improvement system of nuclear power plant of Laguna Verde; El sistema de mejora continua de la central nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km. 42.5 Cardel-Nautla, Veracruz (Mexico)], e-mail: arr99999@cfe.gob.mx

    2009-10-15

    This paper describes the continuous improvement system of nuclear power plant of Laguna Verde and the achievements in implementing the same and additionally two study cases are presents. In February 2009 is noteworthy because the World Association of Nuclear Operators we identified as a learning organization, qualification which shows that the continuous improvement system has matured, and this system will expose as I get to learn to capitalize on our own experiences and external experiences diffused by the nuclear industry. In 2007 the management of nuclear power plants integrates its improvement systems and calls it continuous improvement system and is presented in the same extensive report that won the National Quality Award. This system is made up of 5 subsystems operating individually and are also related 1) human performance; 2) referential comparison or benchmarking; 3) self-assessment; 4) corrective action and 5) external operating experience. Five subsystems that plan, generate, capture, manage, communicate and protect the knowledge generated during the processes execution of nuclear power plant of Laguna Verde, as well as from external sources. The target set in 2007 was to increase the intellectual capital to always give response to meeting the security requirements, but creating a higher value to quality, customer, environment protection and society. In brief each of them, highlighting the objective, expectations management, implementation and some benefits. At the end they will describe two study cases selected to illustrate these cases as the organization learns by their continuous improvement system. (Author)

  4. Thermal Power Plant Performance Analysis

    CERN Document Server

    2012-01-01

    The analysis of the reliability and availability of power plants is frequently based on simple indexes that do not take into account the criticality of some failures used for availability analysis. This criticality should be evaluated based on concepts of reliability which consider the effect of a component failure on the performance of the entire plant. System reliability analysis tools provide a root-cause analysis leading to the improvement of the plant maintenance plan.   Taking in view that the power plant performance can be evaluated not only based on  thermodynamic related indexes, such as heat-rate, Thermal Power Plant Performance Analysis focuses on the presentation of reliability-based tools used to define performance of complex systems and introduces the basic concepts of reliability, maintainability and risk analysis aiming at their application as tools for power plant performance improvement, including: ·         selection of critical equipment and components, ·         defini...

  5. Occupational exposures of nuclear power plant workers in Finland.

    Science.gov (United States)

    Alm-Lytz, K; Riihiluoma, V; Hyvönen, H

    2001-01-01

    In Finland, the Radiation and Nuclear Safety Authority (STUK) maintains a central dose register where all occupational doses of radiation workers are recorded. The computerised register enables easy control of personal doses, including annual, 5 year and lifetime doses. The type of radiation work is also recorded in the dose register. Finland was one of the first countries in the world to introduce dose limits based on the recommendations of ICRP 60. In this article, the radiation dose data of the Finnish nuclear power plant workers are analysed. The majority of the radiation doses are received during the maintenance outages. The trend of the 5 year doses and their distribution are presented. Doses received during different work assignments were averaged over the years 1996-1999 and they are also discussed in this article.

  6. Power plant VII revisited - Air-air /Scirocco/

    Science.gov (United States)

    Etievant, C.; Royer, D.

    A hybrid fossil fuel-solar central receiver power plant is described, noting principally a 'Scirocco' configuration for the receiver. The primary loop contains air which enters passages in the alveolar-configured walls of the boiler, which is semi-spherically shaped. The alveoles are located in the back of the cavity while the upper and lower surfaces are reflective. A heat flux of 24.4 MWth is delivered to the aperture by 668 heliostats, each having a 53 sq m surface. Air is heated to 660 C and then flows past flame tubes to attain temperatures near 900 C through use of a combustor before impinging on the turbine blades. It is noted that although only 1000 hr of functioning are currently available for the Scirocco configuration, it offers the chance to reduce the size of the boiler. Further studies to optimize the materials for the boiler are indicated.

  7. 塔式太阳能电站集热管非均匀受热特性研究%Heat transfer performance of water-vapor receiver with uneven heat flux in solar power tower plant

    Institute of Scientific and Technical Information of China (English)

    曹传钊; 韩临武; 徐海卫; 刘明义; 裴杰

    2015-01-01

    塔式太阳能电站吸热器中的集热管是光热转换的核心组件。集热管面向镜场的半圆周受热,且热流密度沿圆周和轴向不断变化,背向镜场的半圆周绝热,同时集热管内水-蒸汽工质的沸腾流动换热尤为复杂,研究其受热特性有助于深入了解塔式电站吸热器集热管的整体性能。为此,建立了轴向和周向不均匀热流边界条件下水-蒸汽集热管内的数值模型。基于 Fluent平台,计算三维、非稳态的汽液两相流动,通过模拟分析呈现了管内的汽液两相流动特性,同时揭示了在这种极不均匀热流条件下,集热管的温度分布规律及其传热特性。%Heat collector pipe in receiver of solar thermal power tower plants is a kernel unit to convert solar energy into thermal energy.Only the semi-circumference facing the heliostat field receives heat flux,while the other semi-circumference depart from the heliostat field is adiabatic.What's more,the heat transfer of boiling flow in the pipe with the water-vapor as the working fluid is especially complex.So the understand-ing of the heat transfer characteristics in it is significant and important.Through Fluent software,numeri-cal model of the water-vapor tube under uneven heat flux boundary with semi-circumference heated and the other semi-circumference adiabatic was established.The three-dimensional and unsteady water-vapor two-phase flow was numerically simulated.So,flow characteristics of the two-phase flow were obtained,and temperature distribution and heat transfer characteristics of the tube under uneven heat flux were revealed.

  8. Wake-up receiver based ultra-low-power WBAN

    CERN Document Server

    Lont, Maarten; Roermund, Arthur van

    2014-01-01

    This book presents the cross-layer design and optimization of wake-up receivers for wireless body area networks (WBAN), with an emphasis on low-power circuit design. This includes the analysis of medium access control (MAC) protocols, mixer-first receiver design, and implications of receiver impairments on wideband frequency-shift-keying (FSK) receivers. Readers will learn how the overall power consumption is reduced by exploiting the characteristics of body area networks. Theoretical models presented are validated with two different receiver implementations, in 90nm and 40nm CMOS technology.   • Provides an overview of wireless body area network design from the network layer to the circuit implementation, and an overview of the cross-layer design trade-offs; • Discusses design at both the network or MAC-layer and circuit-level, with an emphasis on circuit design; • Covers the design of low-power frequency shift keying (FSK) wake-up-receivers; • Validates theory presented with two different recei...

  9. Direct Heat-Flux Measurement System (MDF) for Solar central Receiver Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ballestrin, J.

    2001-07-01

    A direct flux measurement system, MDF, has been designed, constructed and mounted on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA) in addition to an indirect flux measurement system based on a CCD camera. It's one of the main future objectives to compare systematically both measurements of the concentrated solar power, increasing in this way the confidence in the estimate of this quantity. Today everything is prepared to perform the direct flux measurement on the aperture of solar receivers: calorimeter array, data acquisition system and software. the geometry of the receiver determines the operation and analysis procedures to obtain the indecent power onto the defined area. The study of previous experiences with direct flux measurement systems ha been useful to define a new simpler and more accurate system. A description of each component of the MDF system is included, focusing on the heat-flux sensors or calorimeters, which enables these measurements to be done in a few seconds without water-cooling. The incident solar power and the spatial flux distribution on the aperture of the volumetric receiver Hitrec II are supplied by the above-mentioned MDF system. The first results obtained during the evaluation of this solar receiver are presented including a sunrise-sunset test. All these measurements have been concentrated in one coefficient that describes the global behavior of the Solar Power Plant. (Author) 18 refs.

  10. Nuclear power plant operation and training

    Energy Technology Data Exchange (ETDEWEB)

    Sanae, Katsushige [Tokyo Electric Power Co., Inc. (Japan); Mitsumori, Kojiro

    1997-07-01

    In this report, the system for operation of a nuclear power plant and the qualities required for its operators were summarized. In Kashiwazaki-Kariwa Atomic Power Plant of the Tokyo Electric Power Co., Inc. operation is continuously made by 6 groups containing each 10 workers on three shifts. A group including the person in charge participates in the operation through cooperation of the control center and the respective spots. The group leaders are chosen from those approved as a person responsible to its operation. The conditions for the person responsible were as follows: to receive simulator training for senior operator, to have more than 7 years experience of operating a nuclear power plant, to pass a practical examination on the ordinary operation and the emergency one, to receive a training course to master the knowledge and techniques for operating an atomic reactor and to success the oral examination on practical knowledge required to perform the duty. Further, the simulators for ABWR training produced by Toshiba Corp. and Hitachi Ltd. were introduced as an example. And the practical training procedures to manipulate the simulator were presented. (M.N.)

  11. State power plant productivity programs

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    The findings of a working group formed to review the status of efforts by utilities and utility regulators to increase the availability and reliability of generating units are presented. Representatives from nine state regulatory agencies, NRRI, and DOE, participated on the Working Group. The Federal government has been working cooperatively with utilities, utility organizations, and with regulators to encourage and facilitate improvements in power plant productivity. Cooperative projects undertaken with regulatory and energy commissions in California, Illinois, New York, Ohio, Texas, North Carolina and Mighigan are described. Following initiation of these cooperative projects, DOE funded a survey to determine which states were explicitly addressing power plant productivity through the regulatory process. The Working Group was formed following completion of this survey. The Working Group emphasized the need for those power plant productivity improvements which are cost effective. The cost effectiveness of proposed availability improvement projects should be determined within the context of opportunities for operating and capital improvements available to an entire utility. The Working Group also identified the need for: allowing for plant designs that have a higher construction cost, but are also more reliable; allowing for recovery and reducing recovery lags for productivity-related capital expenditures; identifying and reducing disincentives in the regulatory process; ascertaining that utilities have sufficient money available to undertake timely maintenance; and support of EPRI and NERC to develop a relevant and accurate national data base. The DOE views these as extremely important aspects of any regulatory program to improve power plant productivity.

  12. An Energy-Efficient MIMO Algorithm with Receive Power Constraint

    CERN Document Server

    Glazunov, Andrés Alayón

    2012-01-01

    We consider the energy-efficiency of Multiple-Input Multiple-Output (MIMO) systems with constrained received power rather than constrained transmit power. A Energy-Efficient Water-Filling (EEWF) algorithm that maximizes the ratio of the transmission rate to the total transmit power has been derived. The EEWF power allocation policy establishes a trade-off between the transmission rate and the total transmit power under the total receive power constraint. The static and the uncorrelated fast fading Rayleigh channels have been considered, where the maximization is performed on the instantaneous realization of the channel assuming perfect information at both the transmitter and the receiver with equal number of antennas. We show, based on Monte Carlo simulations that the energy-efficiency provided by the EEWF algorithm can be more than an order of magnitude greater than the energy-efficiency corresponding to capacity achieving Water-Filling (WF) algorithm. We also show that the energy-efficiency increases with b...

  13. Radiological Impact Study of the Coal-Fired Power Plant of Lada; Estudio del Impacto Radiologico de la Central Termica de Carbon de Lada

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-02-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238{sup U}, 235{sup U}, 232{sup T}h and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Lada coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  14. Radiological Impact Study of the Coal-Fired Power Plant of Meirama; Estudio del Impacto Radiologico de la Central Termica de Carbon de Meirama

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Meirama coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  15. Radiological Impact Study of the Coal-Fired Power Plant of Velilla; Estudio del Impacto Radiologico de la Central Termica de Carbon de Velilla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Mora, J. c.; Trueba, C.; Rodriguez, J.; Baeza, A.; Corbacho, J. a.; Guillen, J.; Miralles, Y.

    2013-10-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238U, 235U, 232Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the non-combustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Velilla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  16. Radiological Impact Study of the Coal-Fired Power Plant of Abono; Estudio del Impacto Radiologico de la Central Termica de Carbon de Abono

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the {sup 4}0K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Abono coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  17. Radiological Impact Study of the Coal-Fired Power Plant of La Robla; Estudio del Impacto Radiologico de la Central Termica de Carbon de La Robla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Mora, J. C.; Trueba, C.; Rodriguez, J.; Baeza, A.; Corbacho, J. A.; Guillen, J.; Miralles, Y.

    2013-07-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238{sup U}, 235{sup U}, 232{sup T}h and also the 40{sup K}, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the non-combustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the La Robla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  18. Radiological Impact Study of the Coal-Fired Power Plant of La Robla; Estudio del Impacto Radiologico de la Central Termica de Carbon de La Robla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the La Robla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  19. Radiological Impact Study of the Coal-Fired Power Plant of Anllares; Estudio del Impacto Radiologico de la Central Termica de Carbon de Anllares

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Anllares coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  20. Advanced Receiver/Converter Experiments for Laser Wireless Power Transmission

    Science.gov (United States)

    Howell, Joe T.; ONeill, Mark; Fork, Richard

    2004-01-01

    For several years NASA Marshall Space Flight Center, UAH and ENTECH have been working on various aspects of space solar power systems. The current activity was just begun in January 2004 to further develop this new photovoltaic concentrator laser receiver/converter technology. During the next few months, an improved prototype will be designed, fabricated, and thoroughly tested under laser illumination. The final paper will describe the new concept, present its advantages over other laser receiver/converter approaches (including planar photovoltaic arrays), and provide the latest experiment results on prototype hardware (including the effects of laser irradiance level and cell temperature). With NASA's new human exploration plans to first return to the Moon, and then to proceed to Mars, the new photovoltaic concentrator laser receiver/converter technology could prove to be extremely useful in providing power to the landing sites and other phases of the missions. For example, to explore the scientifically interesting and likely resource-rich poles of the Moon (which may contain water) or the poles of Mars (which definitely contain water and carbon dioxide), laser power beaming could represent the simplest means of providing power to these regions, which receive little or no sunlight, making solar arrays useless there. In summary, the authors propose a paper on definition and experimental results of a novel photovoltaic concentrator approach for collecting and converting laser radiation to electrical power. The new advanced photovoltaic concentrator laser receiver/converter offers higher performance, lighter weight, and lower cost than competing concepts, and early experimental results are confirming the expected excellent Performance levels. After the small prototypes are successfully demonstrated, a larger array with even better performance is planned for the next phase experiments and demonstrations. Thereafter, a near-term flight experiment of the new technology

  1. Plant reproduction in the Central Amazonian floodplains : challenges and adaptations

    OpenAIRE

    Ferreira, Cristiane da Silva; Fernandez Piedade, Maria Teresa; Wittmann, Astrid de Oliveira; Franco, Augusto César

    2010-01-01

    Background The Central Amazonian floodplain forests are subjected to extended periods of flooding and to flooding amplitudes of 10 m or more. The predictability, the length of the flood pulse, the abrupt transition in the environmental conditions along topographic gradients on the banks of major rivers in Central Amazonia, and the powerful water and sediment dynamics impose a strong selective pressure on plant reproduction systems. Scope In this review, we examine how the hydrological cycle i...

  2. Fuel cycle management by the electric enterprises and spanish nuclear Power plants; Gestion del ciclo de combustible por las empresas electricas y centrales nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Celma, E. M.; Gonzalez, C.; Lopez, J. V.; Melara, J.; Lopez, L.; Martinez, J. C.; Culbras, F.; Blanco, J.; Francia, L.

    2015-07-01

    The Nuclear Fuel Group reports to the Technology Committee of the UNESA Nuclear Energy Committee, and is constituted by representatives of both the Spanish Utilities and the Nuclear Power Plants. The Group addresses the nuclear plant common issues in relation to the operation and management of the nuclear fuel in their different stages of the Fuel Cycle. The article reviews the activities developed by the Group in the Front-End, mainly in the monitoring of international programs that define criteria to improve the Fuel Reliability and in the establishment of common bases for the implementation of changes in the regulation applying the nuclear fuel. Concerning the Back-End the Group focuses on those activities of coordination with third parties related to the management of used fuel. (Author)

  3. Remotely Powered Reconfigurable Receiver for Extreme Environment Sensing Platforms

    Science.gov (United States)

    Sheldon, Douglas J.

    2012-01-01

    Wireless sensors connected in a local network offer revolutionary exploration capabilities, but the current solutions do not work in extreme environments of low temperatures (200K) and low to moderate radiation levels (<50 krad). These sensors (temperature, radiation, infrared, etc.) would need to operate outside the spacecraft/ lander and be totally independent of power from the spacecraft/lander. Flash memory field-programmable gate arrays (FPGAs) are being used as the main signal processing and protocol generation platform in a new receiver. Flash-based FPGAs have been shown to have at least 100 reduced standby power and 10 reduction operating power when compared to normal SRAM-based FPGA technology.

  4. Economic impact associated with the decommissioning process of Vandellos I Nuclear Power Plant; Informe final. Impacto economico del desmantelamiento de la central nuclear Vandellos I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Silva, M.

    2005-07-01

    This economic study examines the economic impact associated with the decommissioning process of the Vandellos I Nuclear Power Plant, measured in terms of the global income that generated the ending of the Nuclear Power Plant activity, on the territory. To this end, we will take into account the total investment that has been necessary to complete the process of decommissioning. The economic impact is calculated using the Input- Output methodology. Briefly, the Input-Output model defines a group of accounting relationships that reflect the links taking place within the production system. The Input-Output model is based on the assumption that given an increase (decrease) in the final demand of one sector, this sector should produce more (less) to satisfy this new demand. At the same time, this will lead to demand more (less) intermediate consumption goods from the remainder sectors of the economy. Then, these sectors should produce more (less) and use more (less) intermediate inputs, and so on. Therefore, an increase (decrease) in the final demand of one sector multiplies the effect throughout the economy, following the interdependency relationships that exist among the productive activities. We will start by collecting an exhaustive economic information. This information covers the whole decommissioning process and the whole economic and productive activity of the province of Tarragona. Next, this information is used with the objective of building an Input-Output table of the province that will serve as a base to establish the global economic impact of Vandellos I. The incomes and employment generation has been evaluated in the province of Tarragona that, following the main assumptions, correspond to the global effects of the decommissioning. In addition, we have evaluated the income and employment generation within the region where the nuclear power plant is located. The total income impacts show a high multiplier effect due to the investment carried out during the

  5. What they have in common the engineering from the Spanish nuclear power plants?; Que tienen en comun las ingenierias de las centrales nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Mendez, M.

    2012-11-01

    In recent years, Spain Nuclear Power Plant Engineering have switched their project/task management method to Critical Chain multi-project management, developed by Dr. Goldratt, achieving outstanding results in improving quality and productivity. Multitasking reduction, task and resource synchronizing without the need of exact schedules, implementing a real-time priority information system, relying on the software Concerto, and daily decision making are the basis for the management change that has generated productivity increases of between 20% to 50%, opening new horizons for improvement in other scenarios such as optimizing refueling shutdowns. (Author)

  6. Electric failure on the reactor n.3 of the nuclear power plant of Dampierre; Defaillance electrique sur le reacteur n. 3 de la centrale nucleaire de Dampierre

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-05-15

    This note of information resumes the progress of the electric failure on the reactor n.3 of the nuclear power plant of Dampierre, the organization during the incident, it establishes then a comparison with the incident arisen to Forsmark in 2006 and reminds that it lead in an inspection on behalf of the Asn which noticed that all the procedures had been respected by the operators and did not noticed any abnormality in the maintenance. This event was classified at the level 1 of the international nuclear event scale (INES). (N.C.)

  7. Economic analysis of extended cycles in the Laguna Verde nuclear power plant; Analisis economico de ciclos de extendidos en la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez N, H.; Hernandez M, J.L.; Francois L, J.L. [Facultad de Ingenieria, UNAM, 04510 Mexico D.F. (Mexico)]. E-mail: hermilo@correo.unam.mx

    2004-07-01

    The present work presents a preliminary analysis of economic type of extended cycles of operation of the Unit One in the Laguna Verde nuclear power plant. It is analysed an equilibrium cycle of 18 months firstly, with base to the Plan of Use of Energy of the Federal Commission of Electricity, being evaluated the cost of the energy until the end of the useful life of the plant. Later on an alternative recharge scenario is presented with base to an equilibrium cycle of 24 months, implemented to the beginning of the cycle 11, without considering transition cycles. It is added in both cycles the cost of the substitution energy, considering the unitary cost of the fuel of a dual thermoelectric power station of 350 M We and evaluating in each operation cycle, in both scenarios, the value of the substitution energy. The results show that a reduction of the days of recharge in the cycle of 24 months could make this option but favorable economically. The duration of the period of recharge rebounds in considerable grade in the cost of energy generation for concept of fuel. (Author)

  8. Actinides inventory of the nuclear power plant of Laguna Verde Unit 1; Inventario de actinidos de la Central Nuclear Laguna Verde Unidad 1

    Energy Technology Data Exchange (ETDEWEB)

    Martinez C, E.; Ramirez S, J. R. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Alonso V, G., E-mail: eduardo.martinez@inin.gob.mx [IPN, Escuela Superior de Fisica y Matematicas, Av. Instituto Politecnico Nacional s/n, U. P. Adolfo Lopez Mateos, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico)

    2013-10-15

    At the present time 435 nuclear power reactors exist for the electricity generation operating in the world and 63 in construction. Mexico has two reactors type BWR in the nuclear power plant of Laguna Verde. The nuclear fuel that is used in the nuclear reactors is retired of the reactor core when the energy that this contained has been extracted. This used fuel is known as spent nuclear fuel, the problem with this fuel is that was irradiated inside the reactor and continuous emitting a high radiation, as well as a significant heat quantity when being extracted, for what is necessary to maintain it in cooling and with some shielding to be protected of the radiation that emits. This objective is achieved confining the fuel in the spent nuclear fuel pool, where it is cooled and the same pool provides the necessary shielding to maintain the surroundings in safety radiation levels for the personnel that work in the power plant. An inconvenience of the pools is its limited storage capacity and that after certain time is necessary to remove the fuel, according to the established regulation to continue operating. To correct this inconvenience, two alternatives of spent fuel disposition exist, 1) the final disposition in deep geologic repositories and 2) the reprocessing and recycled of spent fuel. Each alternative presents its particularities and specific problems; however taking many years to be able to implement anyone of them. To carry out the second option, is indispensable to estimate the total mass of actinides generated in the spent nuclear fuel, that which represents to develop a methodology for it, this action is the main purpose of the present work. Inside our calculation method was necessary to appeal to diverse computation tools as the codes Origin-S and Keno V.a. Later on the obtained were compared with a problem type Benchmark, being obtained a smaller absolute error to 1.0%. (Author)

  9. Thermoelectric power plant conversion from fuel oil to coal with integration of a CO{sub 2} capture plant. Part 1; Conversion de una central termoelectrica de combustoleo a carbon con integracion de una planta de captura de CO{sub 2}. Parte 1

    Energy Technology Data Exchange (ETDEWEB)

    Huante Perez, Liborio; Rodriguez Martinez, J. Hugo; Arriola Medellin, Alejandro M. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2010-11-15

    The major features in the design of power plant conversion from fuel oil to coal, considering the new technical characteristics of fuel and his transportation to plant, equipment required to comply with Mexican environmental standards and additional requirements of auxiliaries are described. In addition, changes needed on power plant design were considered according to integrates CO{sub 2} capture plant alternatives. [Spanish] En este articulo se describen las caracteristicas principales en el diseno de la conversion de Centrales de combustoleo a carbon, considerando el nuevo combustible y su transporte hasta la central, los equipos requeridos para cumplir con las normas ambientales y los requerimientos adicionales de los servicios auxiliares. Adicionalmente, se lleva a cabo el analisis de los cambios requeridos en el diseno de la conversion considerando diferentes opciones para la integracion de una planta de captura de CO{sub 2}, la cual debera entregar este subproducto para su compresion y envio a su destino final para su almacenamiento.

  10. Proceedings of a Topical Meeting On Small Scale Geothermal Power Plants and Geothermal Power Plant Projects

    Energy Technology Data Exchange (ETDEWEB)

    None

    1986-02-12

    These proceedings describe the workshop of the Topical Meeting on Small Scale Geothermal Power Plants and Geothermal Power Plant Projects. The projects covered include binary power plants, rotary separator, screw expander power plants, modular wellhead power plants, inflow turbines, and the EPRI hybrid power system. Active projects versus geothermal power projects were described. In addition, a simple approach to estimating effects of fluid deliverability on geothermal power cost is described starting on page 119. (DJE-2005)

  11. Assessment of occupational radiation protection conditions during power enhancement of the Angra-2 nuclear power plant; Avaliacao das condicoes de radioprotecao ocupacional durante a elevacao de potencia na Unidade 2 da Central Nuclear Almirante Alvaro Alberto - Angra-2

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Eduardo M.; Rocha, Antonio Carlos S.; Ferreira, Paulo R.R.; Mouco, Charles Dickens C.L.; Godoy, Jose M.O.; Matta, Luiz E.S.C. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil)

    2001-07-01

    This paper intend to analyse the occupational radioprotection conditions of the Angra-2 nuclear power plant, from the startup up to reach 100% of the nominal power. To perform this work a group of dose rates measures was made including beta/gamma and neutron radiation, particulates and iodine monitoring, and surface contamination, during the whole process. These measures were made inside of the three main buildings: the reactor buildings (UJA - reactor core and UJB) and the Reactor Auxiliary Building (UKA). (author)

  12. Development of database for spent fuel and special waste from the Spanish nuclear power plants; Desarrollo de la base de datos para el combustible gastado y residuos especiales de las centrales nucleares espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Gandal, R.; Rodriguez Gomez, M. A.; Serrano, G.; Lopez Alvarez, G.

    2013-07-01

    GNF Engineering is developing together with ENRESA and with the UNESA participation, the spent fuel and high activity radioactive waste data base of Spanish nuclear power plants. In the article is detailed how this strategic project essential to carry out the CTS (centralized temporary storage) future management and other project which could be emerged is being dealing with, This data base will serve as mechanics of relationship between ENRESA and Spanish NPPS, covering the expected necessary information to deal with mentioned future management of spent fuel and high activity radioactive waste. (Author)

  13. Modular plants with high power gas engines (1 to 30 MWe); Centrales modulaires a moteurs gaz de forte puissance (de 1 a 30 MWe)

    Energy Technology Data Exchange (ETDEWEB)

    Haushalter, J. [Wartsila (France)

    1997-12-31

    This paper is a series of transparencies about the high power gas engines manufactured by Waertsilae NSD Corporation company. The first par recalls the NO{sub x} and CO air pollution regulations worldwide, the German TA-Luft standards and the French 2910 by-law according to the engine type (2 and 4 stroke, dual-fuel, natural gas, LPG, others..) and to the type of pollutants (NO{sub x}, dusts, SO{sub 2}, CO, noise..). The second part presents the Waertsilae NSD Corporation concept of gas-fueled spark ignition engines (Otto cycle, emissions, performances, technology, fuel system, combustion optimization, fuel-air ratio regulation, pollution control equipment) and of the `pure energy` global concept of plants. (J.S.)

  14. Distributed generation and centralized power system in Thailand

    DEFF Research Database (Denmark)

    Sukkumnoed, Decharut

    The paper examines and discusses conflicts between the development of distributed power and centralized power system in Thailand.......The paper examines and discusses conflicts between the development of distributed power and centralized power system in Thailand....

  15. Distributed generation and centralized power system in Thailand

    DEFF Research Database (Denmark)

    Sukkumnoed, Decharut

    2004-01-01

    The paper examines and discusses conflicts between the development of distributed power and centralized power system.......The paper examines and discusses conflicts between the development of distributed power and centralized power system....

  16. 76 FR 20624 - Oglethorpe Power Corporation: Proposed Biomass Power Plant

    Science.gov (United States)

    2011-04-13

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF AGRICULTURE Rural Utilities Service Oglethorpe Power Corporation: Proposed Biomass Power Plant AGENCY: Rural... Corporation (Oglethorpe) for the construction of a 100 megawatt (MW) biomass plant and related...

  17. Monte-Carlo RAY tracing simulation of a falling particle receiver in connection with a central receiver field

    Energy Technology Data Exchange (ETDEWEB)

    Alxneit, I. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    The program RAY was developed to perform Monte-Carlo simulations of the flux distribution in solar reactors in connection with an arbitrary heliostat field. The code accounts for the shading of the incoming rays from the sun due to the reactor supporting tower as well as for full blocking and shading of the heliostats among themselves. A simplified falling particle reactor (FPR) was evaluated. A central receiver field was used with a total area of 311 m{sup 2} composed of 176 round, focusing heliostats. No attempt was undertaken to optimise either the geometry of the heliostat field nor the aiming strategy of the heliostats. The FPR was evaluated at two different geographic latitudes (-8.23W/47.542N; PSI and -8.23W/20.0N) and during the course of a day (May 30{sup th}). The incident power passing through the reactor aperture and the flux density distribution within the FPR was calculated. (author) 3 figs., 1 tab., 3 refs.

  18. Indoor Thermal Comfort Analysis of Centralized Control Room in Thermal Power Plant%火力发电厂集中控制室室内热舒适性研究

    Institute of Scientific and Technical Information of China (English)

    倪明龙; 张英俊; 刘明涛; 盛帮明; 黄艺

    2014-01-01

    There are some deficiencies about staff comfort on air conditioning design of the centralized control room in China thermal power plants .Combined thermal comfort with the actual situation in power plant ,the influence of indoor temperature ,in-door humidity and wind speed of working area on the thermal comfort of centralized control room has been studied by the PMV -PPD evaluation indicators .Found that the electric power industry standard DL/T 5035-2004 provisions on the centralized control room indoor winter and summer air conditioning system design parameters failed to fully consider the indoor thermal comfort .Rea-sonable suggestions were given and provided the reference for the design personnel .%目前我国火力发电厂集中控制室空调设计在人员舒适性方面考虑不足。从热舒适角度出发,结合电厂实际情况,采用PMV-PPD评价指标探讨温度、湿度及工作区风速3个因素对集控室内热舒适性的影响。发现现行电力行业标准DL/T 5035-2004中关于集控室室内冬、夏季空调系统设计参数的规定未能充分考虑室内人员的热舒适性,并给出合理建议,为设计人员提供参考。

  19. Evaluation of line focus solar central power systems. Volume I. Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. This volume is an executive summary. (WHK)

  20. Concept and controllability of virtual power plant

    Energy Technology Data Exchange (ETDEWEB)

    Setiawan, E.A.

    2007-07-01

    In the end of 20th century the conception of electrical power supply is morphing gradually from centralized into decentralized system, indicated by increasing the installation of distributed generation on the main grid. With emerging of advanced communication and information technology, the aggregation control of several DG units can be developed as virtual power plant in order to provide added-value to the electric power system. This thesis presents definitions and types of Virtual Power Plants (VPP), then developing control through numerical simulation. The thesis proposes three DG controls namely Basic Autocontrol System (BAS), Smart Autocontrol System (SAS) and Tracking Efficiency Autocontrol System (TEAS). The BAS controls the DG output power with the objective to cover the local load demand. The drawback of this system is that the coordination among DG units is not established yet. In contrast to the BAS, the SAS has a control coordination centre which is responsible of controlling a certain number of DG units. The SAS controls and coordinates the operation of the dedicated DG units in order to minimize power exchange with the superior grid. However the efficiency issue is not considered at two previous control systems, therefore the TEAS was developed. Principally this system is similar to the SAS in terms of information exchange but additionally optimizes the operation efficiency of DG units. This is accomplished by tracking the systems' most efficient operation point. All control systems have been implemented into a simulation environment. The simulation results show that all developed control systems are capable to minimize the power exchange with the superior grid. The systems are able to follow changing load conditions. Furthermore the simulation results prove the ability of TEAS to optimize the system efficiency. Finally the contribution of VPP to voltage regulation is investigated with several scenarios. The influence of both, active and reactive

  1. The PFBC Power Plant of Escatron; Proyecto de Demostracion de la Combustion en Lecho Fuido a Presion Central Termica de Escatron

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The Escatron Pressurized Fluidized Bed Combustion Demonstration Plant was led by ENDESA which set out on the Project with its own specific objectives, and also have involved contributions from designers and suppliers, as ABB and BWE. The project objectives may be defined as follows: To make progress in the development of clean and efficient technology applicable to a wide range of coal types, specially to the peculiar Spanish black lignites. To be able to design and manufacture a new technology in the contest of European Union, specially developing capacity in Spain. All this give rise to a framework which took shape in the Escatron Project Monitoring Committee. Sulphur retention in PFBC technology has proved to be efficient, with levels higher than 90%. The nitric oxides emissions fall within limits set by present regulations. It is likely that more restrictive regulations in the future, will require the consideration of injecting ammonium technic over free-chamber bed. The most significant problem is that the flue gas from the cyclones to the gas turbine, has a high dust content. The cleaning system for this gas should be improved, and the best option appear to be the introduction of ceramic filters. The new plants could be built at higher power, as should be 300-400 MWe, operating with higher pressure (16 bar). This option together with better steam conditions, gives rise to a better energy yields and competitive electric energy production. But we should not dimis more proved designs of 100-200 MWe, as an interesting modular solution. (Author)

  2. Actions for the environmental adequateness and emissions control at the Martin del Corral power plant-Termozipa; Obras de adecuacion ambiental y control de emisiones para la central termoelectrica Martin del Corral - Termozipa

    Energy Technology Data Exchange (ETDEWEB)

    Arevalo Osorio, Luis [Empresa de Energia de Bogota, Bogota (Colombia)

    1996-12-31

    In this paper the general data on the Martin del Corral-Termozipa, of Colombia, fossil fueled power plant are exposed. The results of a study to determine the environmental impact originated in the influence zone of this Power Plant are presented, particularly on the Bogota River. The study was framed into the environmental policy driven by the Colombian sector. Different solutions addressed to the optimization of the handling, capacity and control of the emissions and counteract the pollution possibilities of the Bogota River are described [Espanol] En esta ponencia se exponen datos generales de la central termoelectrica Martin del Corral - Termozipa-, de Colombia. Se presentan los resultados de un estudio para determinar el impacto ambiental ocasionado en la zona de influencia de esta central, y en particular sobre el rio Bogota. El estudio se enmarco dentro de la politica ambiental impulsada por el sector colombiano. Se describen diversas soluciones encaminadas a optimizar el manejo, capacidad y control de las emisiones y contrarrestar las posibilidades de contaminacion del rio Bogota

  3. Advanced Coordinating Control System for Power Plant

    Institute of Scientific and Technical Information of China (English)

    WU Peng; WEI Shuangying

    2006-01-01

    The coordinating control system is popular used in power plant. This paper describes the advanced coordinating control by control methods and optimal operation, introduces their principals and features by using the examples of power plant operation. It is wealthy for automation application in optimal power plant operation.

  4. A simple model to evaluate the impact of the thermal power plants emissions; Un modelo simple para evaluar el impacto de las emisiones de centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Rodas Grapain, Arturo; Salcido, Alejandro [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    Formulation and validation of a dispersion model for relative plumes are presented in this paper. This model (MOTTQUIP: Modelo de Transporte Turbulento y Quimico de Plumas) was developed to assess the environmental impact of power generation. The theoretical formulation if this model is based on the integral form of the mass balance equation. MOTTQUIP can simulate (in two dimensions) the turbulent dispersion and chemical transformation phenomena of a nitrogen oxides (Nox) non-buoyant plume in an ozone (O{sub 3}) atmosphere. The results produced by MOTTQUIP, however, can run in a personal computer consuming relatively short CPU times. [Spanish] En este trabajo se presentan la formulacion y la validacion de un modelo (MOTTQUIP: Modelo de Transporte Turbulento y Quimica de Plumas) para evaluar el impacto de las emisiones de contaminantes reactivos de centrales termoelectricas. Este modelo se formula a partir de la forma integral de la ecuacion de balance de masa, y no de su forma diferencial, como se procede generalmente. MOTTQUIP simula, en dos dimensiones, la dispersion turbulenta y transformacion quimica de una pluma no flotante de oxidos de nitrogeno (Nox), misma que se interna paulatinamente en un ambiente de ozono (O{sub 3}). Los resultados obtenidos son comparados con los de modelos alternos que simulan el mismo sistema reactivo, encontrandose una concordancia bastante aceptable. Una ventaja de MOTTQUIP, sin embargo, es que puede utilizarse en sistemas de computo pequenos, empleando tiempos de CPU relativamente cortos.

  5. Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Slemmons, A J

    1980-04-01

    The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)

  6. Centralized cooling mode based on cogeneration power plant and hot water pi pe network%基于热电厂与热水管网的集中供冷模式

    Institute of Scientific and Technical Information of China (English)

    滕树龙; 赵玉清; 战家乙; 孙健

    2014-01-01

    Describes a new way for summer cooling based on the central heating system of combined heat and power generation.The characteristic is that the absorption heat pump driven by steam extracted from steam turbine is set up in cogeneration power plant.The absorption heat pump is used for recovering waste heat in exhausted steam of steam turbine or circulating cooling water.Network water is heated by cascade utilization.At the user' s heating station,absorption chillers driven by hot water and solution-humidifying air handling units are set up to undertake building cooling load in summer.By this way,high temperature hot water from cogeneration power plant is used to drive refrigeration units in summer,which can improve the equipment utilization rate of the central heating system and reduce the power load of cities in summer.%介绍了一种利用热电联产集中供热系统实现夏季供冷的模式,其特点是在热电厂设置汽轮机抽汽驱动的吸收式热泵,回收汽轮机乏汽或循环冷却水余热,梯级加热热网水;在用户热力站设置热水型吸收式制冷机和溶液调湿型空气处理机,承担用户夏季空调冷负荷。该方式夏季利用热电厂的高温热水驱动制冷机,可提高集中供热系统的设备利用率,降低夏季城市的供电负荷。

  7. Optimizing Waste Heat Recovery for Class A Biosolids Production from a Combined Cycle Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Soroushian, Fred

    2003-07-01

    The City of Corona serves a rapidly growing area of Southern California, The City operates three wastewater treatment plants (WWTPs) that produce reclaimed water for unrestricted reuse. The sludge from the three WWTPs is transported to a central sludge treatment facility located at WWTP No. 1. The sludge treatment facility consists of sludge receiving, thickening, anaerobic digestion, and dewatering. In the year 2000, the City was faced with two crises. First, the California power shortage and escalating cost of power severely impacted the industry and businesses. Second, bans on Class B biosolids land application and the shutdown of a local privatized composting facility where the bulk of the City's biosolids were processed or reused forced the City to transport bulk waste a much greater distance. To cost-effectively respond to these crises, the City decided to start generating and supplying power to its constituents by constructing a nominal 30-megawatt (MW) power plant. The feasibility study proved that locating the power plant at the City's largest WWTP produced significant synergies. The reclaimed water from the WWTP could be used for power plant cooling, the waste heat from the power plant could be recovered and used in Class A biosolids processes, the digester gas could be used for supplementing the fuel needs of the sludge dryer, and the combined facilities operation was more efficient than physically separate facilities. This paper presents the results of this analysis as well as the construction and operational aspects of the project. (author)

  8. Present situation of the control of the transmissions of thermal power plants in Colombia; Situacion actual del control de las emisiones de centrales termoelectricas en Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Lozada, Hector [Consultor Ambiental, Bogota (Colombia)

    1996-12-31

    This paper presents, departing from a historical recollection, the evolution analysis of the Colombian Electric Sector, with emphasis in the electric component performance. Also, a general view is offered on the characteristics of the thermal electric resource in terms of energy production level, type of fuels used and annual amount of air pollutants originated in the combustion process. In the second part of the paper the normative scheme and the regulation for emissions control, particularly coming from power plants; and the tendencies in the policies that for the management of the atmospheric resource are being implemented in the country are identified. [Espanol] En este articulo se presenta, a partir de un breve recuento historico, el analisis de la evolucion del Sector Electrico Colombiano con enfasis en el comportamiento del componente termoelectrico. Asi mismo se ofrece una vision general sobre las caracteristicas del parque termico, en terminos de los niveles de produccion de energia, los tipos de combustibles utilizados y las cantidades anuales de contaminantes atmosfericos que se generan en el proceso de combustion. En la segunda parte del trabajo se comenta el esquema normativo y la regulacion para el control de las emisiones, en particular de las procedentes de plantas termoelectricas; y se identifican las tendencias de las politicas que para la administracion del recurso atmosferico se estan implantando en el pais.

  9. Mercury Bioaccumulation Potential from Wastewater Treatment Plants in Receiving Waters

    Science.gov (United States)

    Dean, J. D.; Mason, R. P.

    2008-12-01

    In early 2007, the Water Environment Research Foundation (WERF) mercury bioavailability project was initiated in response to the establishment of mercury Total Maximum Daily Load (TMDL) criteria around the country. While many TMDLs recognize that point sources typically constitute a small fraction of the mercury load to a water body, the question was raised concerning the relative bioavailablity of mercury coming from various sources. For instance, is the mercury discharged from a wastewater treatment plant more or less bioavailable than mercury contributed from other sources? This talk will focus on the results of a study investigating approaches to the estimation of bioavailability and potential bioaccumulation of mercury from wastewater treatment plants and other sources in receiving waters. From the outset, a working definition of bioavailability was developed which included not only methylmercury, the form that readily bioaccumulates in aquatic food chains, but also bioavailable inorganic mercury species that could be converted to methylmercury within a scientifically reasonable time frame. Factors that enhance or mitigate the transformation of inorganic mercury to methylmercury and its subsequent bioaccumulation were identified. Profiles were developed for various sources of mercury in watersheds, including wastewater treatment plants, with regard to methylmercury and inorganic bioavailable mercury, and the key factors that enhance or mitigate mercury bioavailability. Technologies that remove mercury from wastewater were reviewed and evaluated for their effect on bioavailability. A screening procedure was developed for making preliminary estimates of bioavailable mercury concentrations and fluxes in wastewater effluents and in fresh, estuarine and marine receiving waters. The procedure was validated using several diverse river and reservoir data sets. A "Bioavailability Tool" was developed which allows a user to estimate the bioavailability of an effluent and

  10. Introduction of fuel GE14 in the nuclear power plant of Laguna Verde for the extended increase of power; Introduccion del combustible GE14 en la central nuclear Laguna Verde para el aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, N.; Vargas A, A. F.; Cardenas J, J. B.; Contreras C, P. [CFE, Central Nuclear Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5 (Mexico)]. e-mail: natividad.hernandez@cfe.gob.mx

    2008-07-01

    The project of extended increase of power responds to a necessity of electrical energy in the country, increasing the thermal exit of the reactors of the nuclear power plant of Laguna Verde of 2027 MWt to 2317 MWt. In order to support this transition, changes will make in the configuration of the reactor core and in the operation strategies of the cycle, also they will take initiatives to optimize the economy in fuel cycle. At present in both reactors of the nuclear plant of Laguna Verde fuel GE12 is used. The fuel GE14 presents displays with respect to the GE12, some improvements in the mechanical design and consequently in its performance generally. Between these improvements we can mention: 1. Spacers of high performance. 2. Shielding with barrier. 3. Filter for sweepings {sup d}ebris{sup a}nd 4. Fuel rods of minor partial length. The management of nuclear power plants has decided to introduce the use of fuel GE14 in Laguna Verde in the reload 14 for Unit 1 and of the reload 10 for Unit 2. The process of new introduction fuel GE14 consists of two stages, first consists on subjecting the one new design of fuel to the regulator organism in the USA: Nuclear Regulatory Commission, in Mexico the design must be analyzed and authorized by the National Commission of Nuclear Safety and Safeguards, for its approval of generic form, by means of the demonstration of the fulfillment with the amendment 22 of GESTAR II, the second stage includes the specific analyses of plant to justify the use of the new fuel design in a reload core. The nuclear plant of Laguna Verde would use some of the results of the security analyses that have been realized for the project of extended increase of power with fuel GE14, to document the specific analyses of plant with the new fuel design. The result of the analyses indicates that the reload lots are increased of 116-120 assemblies in present conditions (2027 MWt) to 140-148 assemblies in conditions of extended increase of power (2317 MWt

  11. Modelling of nuclear power plant decommissioning financing.

    Science.gov (United States)

    Bemš, J; Knápek, J; Králík, T; Hejhal, M; Kubančák, J; Vašíček, J

    2015-06-01

    Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article also presents methodology of allocation of future decommissioning costs to the running costs of nuclear power plant in the form of fee imposed on each megawatt hour generated. The application of the methodology is presented in the form of a case study on a new nuclear power plant with installed capacity 1000 MW.

  12. The narrow-gap TIG welding concerns the electric power plants manufacturers; Le soudage en joint etroit suscite l'interet des constructeurs de centrales electriques

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2009-05-15

    Polysoude, France, played host to an expert forum on narrow gap welding from 5-7 November 2008. The successful event welcomed around one hundred experts.The power plant construction sector is currently booming worldwide. For plant construction this means using more pressure-resistant, thick-walled pipes made from high temperature steels. The key quality features of this new steel grade are the values for high creep rupture strength that also apply without restriction as the benchmark for every weld seam on these pipes. In particular, the forum on narrow gap welding addressed this area of automated welding technology. During the forum, Mr Hans-Peter Mariner (Polysoude's CEO), has offered an in-depth insight into the latest developments in narrow gap welding. This presentation highlighted that with wall thicknesses of over 60 mm, welding time is shortened by a factor of five to ten in comparison to conventional TIG processes with a traditional V seam. The welding characteristics of the parent material are the decisive factor in the application of the narrow gap process. Technical advances in equipment technology such as automatic centring, HF-free ignition, seam preparation and optimised gas protection further increase the application limits. The geometry and gap width of the weld groove are based on the mechanical properties of the materials being joined, with the shrinkage characteristics of the seam being particularly important. Another key part of the programme was a presentation on the three different narrow gap-welding techniques. The first involves a single pass weld per layer and torch or work-piece revolution. The second is dual pass welding next to one another, when the seam preparation or positioning exceed the required narrow tolerances of a few tenths of a millimetre for one stringer bead per layer. TIG narrow gap welding with a shuttle-motion electrode is ideal with very large wall thicknesses of 150-200 mm. This is particularly the case if the

  13. Modular stellarator reactor: a fusion power plant

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.L.; Bathke, C.G.; Krakowski, R.A.; Heck, F.M.; Green, L.; Karbowski, J.S.; Murphy, J.H.; Tupper, R.B.; DeLuca, R.A.; Moazed, A.

    1983-07-01

    A comparative analysis of the modular stellarator and the torsatron concepts is made based upon a steady-state ignited, DT-fueled, reactor embodiment of each concept for use as a central electric-power station. Parametric tradeoff calculations lead to the selection of four design points for an approx. 4-GWt plant based upon Alcator transport scaling in l = 2 systems of moderate aspect ratio. The four design points represent high-aspect ratio. The four design points represent high-(0.08) and low-(0.04) beta versions of the modular stellarator and torsatron concepts. The physics basis of each design point is described together with supporting engineering and economic analyses. The primary intent of this study is the elucidation of key physics and engineering tradeoffs, constraints, and uncertainties with respect to the ultimate power reactor embodiment.

  14. SUBSTANTIAL AND STRUCTURAL COMPONENTS OF THE MENTAL STATUS OF THE PERSONS WHO HAVE RECEIVED SMALL DOSES OF RADIATION DURING LIGUIDATION OF THE ACCIDENT AT THE CHERNOBYL NUCLEAR POWER PLANT

    Directory of Open Access Journals (Sweden)

    О. V. Baranova

    2012-01-01

    Full Text Available In the article the peculiarities of ideas about the catastrophe at the Chernobyl nuclear power plant disaster at the persons who have suffered from radiation during liquidation of the accident’s consequences. View of the accident was considered as a key element of a person’s mind, in particular the adaptive. There were 30 persons, who took part in the research – participants of Chernobyl disaster’s liquidation, veterans of division of an extra risk. The subjective assessment of mental health at persons who survived in Chernobyl disaster was defined; personal properties of victims were revealed; interrelations between personal properties and subjective assessment of mental health were established. It is possible to assume that in process of moving away from the moment of the accident the content of view of Chernobyl disaster shows concentration of the person on experience of mental health and the personal potential.

  15. Sabotage at Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Purvis, James W.

    1999-07-21

    Recently there has been a noted worldwide increase in violent actions including attempted sabotage at nuclear power plants. Several organizations, such as the International Atomic Energy Agency and the US Nuclear Regulatory Commission, have guidelines, recommendations, and formal threat- and risk-assessment processes for the protection of nuclear assets. Other examples are the former Defense Special Weapons Agency, which used a risk-assessment model to evaluate force-protection security requirements for terrorist incidents at DOD military bases. The US DOE uses a graded approach to protect its assets based on risk and vulnerability assessments. The Federal Aviation Administration and Federal Bureau of Investigation conduct joint threat and vulnerability assessments on high-risk US airports. Several private companies under contract to government agencies use formal risk-assessment models and methods to identify security requirements. The purpose of this paper is to survey these methods and present an overview of all potential types of sabotage at nuclear power plants. The paper discusses emerging threats and current methods of choice for sabotage--especially vehicle bombs and chemical attacks. Potential consequences of sabotage acts, including economic and political; not just those that may result in unacceptable radiological exposure to the public, are also discussed. Applicability of risk-assessment methods and mitigation techniques are also presented.

  16. Advantages of using 3D design tools in the nuclear power plants projects; Ventajas del uso de herramientas de diseno 3D en los proyectos de centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Roldan, P.; Melendro, J.; Gomez, A.; Hermana, I.

    2011-07-01

    It there is anything that distinguished Iberdrola Ingeneria y Construccion, as part of the Iberdrola Group, it is its firm commitment to innovation and continuous improvement. This is the philosophy that led the company to its interest in three-dimensional design tools back when they were in an early stage of development : very little international implementation, lack of integration with other applications, absence of previous experiences to understand the best possible configuration for each case, etc. Nevertheless, the company was able to see the tremendous advantage of having a construction program in the early months of a project- a detailed program that could predict, and therefore avoid, the problems that, if not anticipated, would arise in the construction phase when they result in higher costs, longer time frames and a multitude of complications. This is precisely what 3D design tools offer prediction and this has been proven in the latest combined cycle projects executed with these tools. A project executed without errors not only decreases cost and time overruns, but also necessarily increases the quality of the end result. Efficiency and quality: these are both basic goals of Iberdrola Ingenieria y Construccion. The knowledge of and skill in the use of these tools have grown at the same time that their development has reached increasingly higher levels. As a result, Iberdrola Ingenieria y Conctruccion now has intensive experience in the use of 3D design tools and is preprared for the future challenges posed by these tools, the capabilities of which have attained such heights that it is possible to take on one of the most technically challenging projects that exists a nuclear power plant. And we are ready. (Author)

  17. Advances in the research line of diagnosing of faults in fossil fuel power plants; Avances en la linea de investigacion de diagnostico de fallas en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Ruz H, Jose A [Universidad Autonoma del Carmen, Campeche (Mexico); Sanchez C, Edgar N [Centro de Investigacion y Estudios Avanzados del Instituto Politecnico Nacional, Mexico, D.F. (Mexico); Suarez Cerda, Dionisio A; Quintero R, Agustin [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2006-07-01

    This article deals with a research in progress searching to take care of the faults that occur with greatest frequency in the fossil fuel power plants of Mexico with the aid of tools of computational intelligence such as the neuronal networks and the fuzzy logic, for the online recognition of the dynamic behavior patterns of variable groups. What this research looks for is the development of individual systems, in relation to the computational intelligence techniques that continuously supervise the functioning of the unit and inform the operator of the eventual faults in the understanding that on time attention to the faults will result in a minimum cost. The advantages of these diagnosis mechanisms are established in comparison to alternative diagnosis methods, such as their associative memory useful to store fault patterns. [Spanish] Se trata de una investigacion en progreso que busca atender las fallas que ocurren con mayor frecuencia en las unidades termoelectricas de Mexico con la ayuda de herramientas de inteligencia computacional como las redes neuronales y la logica difusa, para el reconocimiento en linea de patrones de comportamiento dinamico de grupos de variables. Lo que esta investigacion busca es desarrollar sendos sistemas, en relacion a las tecnicas de inteligencia computacional, que supervisen continuamente el funcionamiento de la unidad e informen al operador de fallas eventuales, en el entendido que la oportuna atencion a fallas redituara en un costo minimo. Las ventajas de estos mecanismos de diagnostico se establecen en comparacion a metodos de diagnostico alternativos, como su memoria asociativa util para almacenar patrones de falla.

  18. 78 FR 26747 - Oglethorpe Power Corporation: Proposed Biomass Power Plant

    Science.gov (United States)

    2013-05-08

    ... Rural Utilities Service Oglethorpe Power Corporation: Proposed Biomass Power Plant AGENCY: Rural... construction of a 100 megawatt (MW) biomass plant and related facilities (Proposal) in Warren County, Georgia... the 100 megawatt (MW) biomass plant and related facilities (Proposal) in Warren County,...

  19. Efficiency of Modern Power Plants of Thermal Power Stations

    Directory of Open Access Journals (Sweden)

    B. V. Yakovlev

    2007-01-01

    Full Text Available The paper considers efficiency and prospects in development of different types of fossil-fuel power plants – gas turbine, steam turbine and combined (gas and steam cycles.The paper provides information on plant selection, fuel consumption, specific output cost. It describes main advantages of various power plants.

  20. Hybrid wind-power-distillation plant

    OpenAIRE

    Ninić Neven; Klarin Branko; Tolj Ivan

    2012-01-01

    This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen usi...

  1. Solar Power System SPS: a small 10 kWe pilot plant for solar thermal power production; Solar Power System SPS: projet d'une mini centrale pilote electro-thermo-solaire de 10 kWe

    Energy Technology Data Exchange (ETDEWEB)

    Pecoud, C.; Breguet, R.; Allani, Y.

    2000-07-01

    This rapport presents the second phase of the development of a concentrating solar collector, including performance optimisation and manufacturing cost reduction. This collector of the parabolic trough type is intended to be used in small units for solar thermal power production in countries with sunny arid climate, with an electric power of about 10 kW. Various technical aspects of the parabolic trough construction like mechanical rigidity, choice of the different materials and welding problems as well as the adopted solutions are described. Comments are given on the economic future of this product and potential clients.

  2. Low-profile heliostat design for solar central receiver systems

    Science.gov (United States)

    Fourakis, E.; Severson, A. M.

    1977-01-01

    Heliostat designs intended to reduce costs and the effect of adverse wind loads on the devices were developed. Included was the low-profile heliostat consisting of a stiff frame with sectional focusing reflectors coupled together to turn as a unit. The entire frame is arranged to turn angularly about a center point. The ability of the heliostat to rotate about both the vertical and horizontal axes permits a central computer control system to continuously aim the sun's reflection onto a selected target. An engineering model of the basic device was built and is being tested. Control and mirror parameters, such as roughness and need for fine aiming, are being studied. The fabrication of these prototypes is in process. The model was also designed to test mirror focusing techniques, heliostat geometry, mechanical functioning, and tracking control. The model can be easily relocated to test mirror imaging on a tower from various directions. In addition to steering and aiming studies, the tests include the effects of temperature changes, wind gusting and weathering. The results of economic studies on this heliostat are also presented.

  3. Technological tendencies for the development and implementation of fault tolerant active controls in combined cycle power plants; Tendencias tecnologicas para el desarrollo e implantacion de controles activos tolerantes a fallas en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez P, Marino; Verde R, Cristina [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2006-07-01

    This document proposes a methodology that reunites support tools for the operator of a Combined Cycle Generating Power Station allowing him to identify and to classify gas turbine faults, it also reunites some tools for the generation of action advices in the decision making on the operation maneuvers necessary to counteract the effects caused by faults. We are talking about a system implemented in a power station with the reconfiguration of processes and fault arrangement capacities. For this purpose, the line of exhibition delimits first the existing knowledge on automatic control and operations supervision systems in a CCPP and immediately emphasizes the cracks of the system to let pass to the fault tolerant active control system that will detect faults of the gas and steam turbo-generators of a Combined Cycle Generating Power Plant. [Spanish] El presente documento propone una metodologia que reuna herramientas de ayuda al operador de una Central Generadora de Electricidad de Ciclo Combinado para permitirle la identificacion y clasificacion de fallas en las turbinas de gas, asi como herramientas para la generacion de consejos de accion en la toma de decisiones sobre las maniobras de operacion necesarias para contrarrestar los efectos provocados por fallas. Se trata principalmente de un sistema implantado en una central con las capacidades de re-configuracion de procesos y acomodo de fallas. Para esto, la linea de exposicion delimita primero el conocimiento existente sobre sistemas automaticos de control y supervision de operacion en una CGCC y resalta enseguida las grietas del sistema para darle paso al sistema de control activo tolerante a fallas que detectara fallas de los turbogeneradores de gas y vapor de una Central Generadora de Electricidad de Ciclo Combinado.

  4. Construction, Maintenance and Demolition of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Smet, Camiel de [Hilti Corporation, P.O. Box 333, FL-9494 Schaan (Liechtenstein)

    2008-07-01

    Hilti is your reliable partner in nuclear power plant construction, maintenance and demolition worldwide. Professional advice and innovative solutions for virtually every phase of construction and supply technologically leading products and systems to increase your productivity and help to create and maintain safe and lasting plants is offered. The solutions for nuclear power plants construction, maintenance and demolition have been employed with great success in many different countries on a wide variety of projects due in no small way to their worldwide availability. An unbroken, international exchange of experience upholds a permanent innovation process. This assures our customers that they always receive products on the very latest technological standard. This paper is not intended to cover all topics related to nuclear power plants. The idea is more to give a kind of an overview. The paper covers briefly the following topics: safety (corrosion and fire), fastenings, measuring and finally decommissioning of nuclear power plants. (author)

  5. Thermal power plant design and operation

    CERN Document Server

    Sarkar, Dipak

    2015-01-01

    Thermal Power Plant: Design and Operation deals with various aspects of a thermal power plant, providing a new dimension to the subject, with focus on operating practices and troubleshooting, as well as technology and design. Its author has a 40-long association with thermal power plants in design as well as field engineering, sharing his experience with professional engineers under various training capacities, such as training programs for graduate engineers and operating personnel. Thermal Power Plant presents practical content on coal-, gas-, oil-, peat- and biomass-fueled thermal power

  6. General digitalized system on nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Akagi, Katsumi; Kadohara, Hozumi; Taniguchi, Manabu [Mitsubishi Electric Corp., Tokyo (Japan)

    2000-08-01

    Hitherto, instrumentation control system in a PWR nuclear power plant has stepwisely adopted digital technology such as application of digital instrumentation control device to ordinary use (primary/secondary system control device, and so on), application of CRT display system to monitoring function, and so forth, to realize load reduction of an operator due to expansion of operation automation range, upgrading of reliability and maintenance due to self-diagnosis function, reduction of mass in cables due to multiple transfer, and upgrading of visual recognition due to information integration. In next term PWR plant instrumentation control system, under consideration of application practice of conventional digital technology, application of general digitalisation system to adopt digitalisation of overall instrumentation control system containing safety protection system, and central instrumentation system (new type of instrumentation system) and to intend to further upgrade economics, maintenance, operability/monitoring under security of reliability/safety is planned. And, together with embodiment of construction program of the next-term plant, verification at the general digitalisation proto-system aiming at establishment of basic technology on the system is carried out. Then, here was described on abstract of the general digitalisation system and characteristics of a digital type safety protection apparatus to be adopted in the next-term plant. (G.K.)

  7. Trends of Nuclear Power Plant support engineering in the Early 21st century; Tendencias de la ingenieria de apoyo a las centrales nucleares a principios del siglo XXI centrales nucleares a principios del siglo XXI

    Energy Technology Data Exchange (ETDEWEB)

    Cerezo, L. M.

    2001-07-01

    The rapid shift towards deregulation in the Electricity Industry in the 21st Century is placing a dramatic new emphasis on mid-term returns on generation investments. The economic pressures on capital-intensive generation systems such as hydraulic, coal and in particular nuclear are escalating significantly. In the old regulated system, the only concern was with marginal production costs, not total costs, as the return on the investment was ensured. Marginal production costs of Nuclear Power Plants are very low, which makes these plants ideal for base operation, but when the costs of recovering the investment are included, the total nuclear Kwh costs are relatively high. In addition, this industry is characterized by some specific economic risks resulting from the following: the risk of accidents, which, though not very probable, have a significant impact on the whole industry; the risk of prolonged, unscheduled outages involving prohibitively high costs, given the ratio of fixed/variable costs, the risk that outages are extended for refueling; and regulatory risks, which have major economic repercussions. (Author)

  8. Waste receiving and processing plant control system; system design description

    Energy Technology Data Exchange (ETDEWEB)

    LANE, M.P.

    1999-02-24

    The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed as separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1.

  9. Conceptual Design of a 100 MWe Modular Molten Salt Power Tower Plant

    Energy Technology Data Exchange (ETDEWEB)

    James E. Pacheco; Carter Moursund, Dale Rogers, David Wasyluk

    2011-09-20

    A conceptual design of a 100 MWe modular molten salt solar power tower plant has been developed which can provide capacity factors in the range of 35 to 75%. Compared to single tower plants, the modular design provides a higher degree of flexibility in achieving the desired customer's capacity factor and is obtained simply by adjusting the number of standard modules. Each module consists of a standard size heliostat field and receiver system, hence reengineering and associated unacceptable performance uncertainties due to scaling are eliminated. The modular approach with multiple towers also improves plant availability. Heliostat field components, receivers and towers are shop assembled allowing for high quality and minimal field assembly. A centralized thermal-storage system stores hot salt from the receivers, allowing nearly continuous power production, independent of solar energy collection, and improved parity with the grid. A molten salt steam generator converts the stored thermal energy into steam, which powers a steam turbine generator to produce electricity. This paper describes the conceptual design of the plant, the advantages of modularity, expected performance, pathways to cost reductions, and environmental impact.

  10. Training simulators for power plant operation based in multimedia, intelligent tutorials and virtual reality; Simuladores para entrenamiento en la operacion de centrales basados en multimedia, tutores inteligentes y realidad virtual

    Energy Technology Data Exchange (ETDEWEB)

    Rossano Roman, Miguel; Tavira Mondragon, Jose A.; Romero Jimenez, Guillermo; Buenabad Arias, Maria de los Angeles [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The possibility of utilizing simulators to support the fossil fuel power plants operation personnel training, is analyzed. These simulators can be based in multimedia, intelligent tutorials and virtual reality. The software and hardware advances of these technologies are analyzed and it is concluded that the simulators development for operators training supported in the fore mentioned technologies represents a new alternative for the instruction of personnel of this type of power stations that has to be analyzed and evaluated, since one of the disadvantages of this type of technologies is the equipment and software investment cost [Espanol] Se analiza la posibilidad de utilizar simuladores para ayudar al entrenamiento del personal en la operacion de centrales termoelectricas, dichos simuladores pueden estar basados en multimedia, tutores inteligentes y realidad virtual. Se describen los avances en software y hardware de estas tecnologias y se concluye en que el desarrollo de simuladores para el entrenamiento de operadores apoyados con las tecnologias antes mencionadas representa una nueva alternativa para la instruccion del personal de este tipo de centrales, que hay que analizar y evaluar, ya que una de las desventajas de este tipo de tecnologias es el costo de inversion en equipo y software

  11. Bubbling fluidized bed boiler for Vanaja power plant

    Energy Technology Data Exchange (ETDEWEB)

    Sormunen, R.; Haermae, P.; Vessonen, K.; Ketomaeki, A. [ed.

    1998-07-01

    At the Vanaja Power Plant, on the outskirts of Haemeenlinna, there have been changes which reflect the central goals in IVO`s product development work. At Vanaja, efficiency is combined with environmental friendliness. In the early 1980s, the plant was modernized to produce district heat in addition to electricity. At that time, along with the new gas turbine at the plant, the main fuel, coal, while remaining the fuel for the old boilers, was replaced by natural gas. This year a new type of bubbling fluidized bed boiler enabling continuous use of peat and trial use of biofuels along with coal was introduced at the plant. In addition to the Nordic countries, this kind of technology is required in central eastern Europe, where modernization of ageing power plants is being planned to achieve the best possible solutions in respect of production and the environment. IVO develops a new repair technique for underwater sites

  12. Economics of hybrid photovoltaic power plants

    Energy Technology Data Exchange (ETDEWEB)

    Breyer, Christian

    2012-08-16

    The global power supply stability is faced to several severe and fundamental threats, in particular steadily increasing power demand, diminishing and degrading fossil and nuclear energy resources, very harmful greenhouse gas emissions, significant energy injustice and a structurally misbalanced ecological footprint. Photovoltaic (PV) power systems are analysed in various aspects focusing on economic and technical considerations of supplemental and substitutional power supply to the constraint conventional power system. To infer the most relevant system approach for PV power plants several solar resources available for PV systems are compared. By combining the different solar resources and respective economics, two major PV systems are identified to be very competitive in almost all regions in the world. The experience curve concept is used as a key technique for the development of scenario assumptions on economic projections for the decade of the 2010s. Main drivers for cost reductions in PV systems are learning and production growth rate, thus several relevant aspects are discussed such as research and development investments, technical PV market potential, different PV technologies and the energetic sustainability of PV. Three major market segments for PV systems are identified: off-grid PV solutions, decentralised small scale on-grid PV systems (several kWp) and large scale PV power plants (tens of MWp). Mainly by application of 'grid-parity' and 'fuel-parity' concepts per country, local market and conventional power plant basis, the global economic market potential for all major PV system segments is derived. PV power plant hybridization potential of all relevant power technologies and the global power plant structure are analyzed regarding technical, economical and geographical feasibility. Key success criteria for hybrid PV power plants are discussed and comprehensively analysed for all adequate power plant technologies, i.e. oil, gas and

  13. Simulators predict power plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, R.

    2002-07-01

    Mix the complexity of a new construction or major retrofit project with today's 'do more with less', a pinch of 'personnel inexperience,' and a dash of 'unintended consequences', and you have got a recipe for insomnia. Advanced simulation tools, however, can help you wring out your design train your operators before the first wire is terminated and just may be get a good night's rest. The article describes several examples of uses of simulation tools. Esscor recently completed a simulation project for a major US utility exploring the potential for furnace/duct implosion that could result from adding higher volumetric flow induced-draft fans and selective catalytic reduction to a 650-MW coal-fired plant. CAF Electronics Inc. provided a full-scope simulator for Alstom's KA24-1 combined-cycle power plant in Paris, France. Computational fluid dynamics (CFD) tools are being used by the Gas Technology Institute to simulate the performance of the next generation of pulverized coal combustors. 5 figs.

  14. On line chemical analyzers for high purity steam and water, applied to steam power plants; Analizadores quimicos en linea para agua y vapor de alta pureza, aplicados a centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Perez, Ruth [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    This article presents a general overview of the advances in the subject of on line analyzers of chemical parameters for high purity water and steam and specifies which ones are commercially available. Also are mentioned besides, the criteria nowadays applied for the selection of the sites for sample grabbing and the analysis that is necessary to perform in each point, depending on the power plant type and the treatment administered (phosphates-Ph coordinated or AVT treatment). [Espanol] El articulo presenta un panorama general de los avances que en materia de analizadores de parametros quimicos en linea para agua y vapor de alta pureza, y especifica cuales estan disponibles en forma comercial. Se citan, ademas los criterios que se aplican actualmente para seleccionar los puntos de toma de muestra y los analisis que es necesario efectuar en cada punto, dependiendo del tipo de central y del tratamiento que se le administre (fosfatos-pH coordinado o tratamiento AVT).

  15. Discussion on Power Market Mode of Central China

    Institute of Scientific and Technical Information of China (English)

    He Zhaocheng; Ye Qing

    2007-01-01

    @@ Central China power system is one of the large regional power grids carrying out power market demonstrative project. Because of lacking power market experience, a lot of problems need to be thoroughly discussed.

  16. 15 years of production of electric energy of the Laguna Verde power plant, its plans and future; 15 anos de produccion de energia electrica de la Central Laguna Verde, sus planes y futuro

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A. [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)]. e-mail: arr99999@cfe.gob.mx

    2005-07-01

    In the year 2005 Laguna Verde power plant reaches 15 years of producing electric power in Mexico arriving to but of 100 million Megawatts-hour from their beginning of commercial activities. The Unit 1 that entered at July 29, 1990 and the Unit 2 at April 10, 1995, obtaining the Disposability Factors from their origin is: 84.63% in Unit 1 and 83.67% in Unit 2. The march of the X XI century gives big challenges of competition to the Laguna Verde Central, with the possible opening of the electric market to private investment, for their Goals and Objectives of a world class company, taking the evaluation system and qualification of the World Association of Nuclear Operators (WANO) that promotes the Excellence in the operation of the nuclear power stations in all their partners. This Association supports the development of programs that allow the monitoring of the behavior in Safety Culture, Human fulfilment, Equipment reliability, Industrial Safety, Planning, Programming and Control, Personalized Systematic Training, and the use of the Operational experience in the daily tasks. The present work tries to explain the system of evaluation/qualification of WANO, the definition of Goals and Objectives to reach the excellence and of the programs, it will present the Program of the Reliability of Equipment with its main actions the productivity. (Author)

  17. Modular plants with high power gas engines (1 to 30 MWe); Centrales modulaires a moteurs gaz de forte puissance (de 1 a 30 MWe)

    Energy Technology Data Exchange (ETDEWEB)

    Haushalter, J. [Wartsila NSD (France)

    1997-12-31

    After a review of pollution regulations in France and Europe for high capacity combustion plants, the Wartsila NSD spark ignition combustion system, using natural gas, is presented: the air-gas mixture in the combustion chamber is very weak (lambda is around 2-2.2) and its ignition is completed by the flame exiting the pre-chamber containing a stoichiometric mixture, and the spark plug. The temperature is decreased thus lowering the NOx emission level. The combustion system is integrated in the Pure Energy global concept (cogeneration plants, etc.) from Wartsila

  18. Detecting Cyber Attacks On Nuclear Power Plants

    Science.gov (United States)

    Rrushi, Julian; Campbell, Roy

    This paper proposes an unconventional anomaly detection approach that provides digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) with the capability to probabilistically discern between legitimate protocol frames and attack frames. The stochastic activity network (SAN) formalism is used to model the fusion of protocol activity in each digital I&C system and the operation of physical components of an NPP. SAN models are employed to analyze links between protocol frames as streams of bytes, their semantics in terms of NPP operations, control data as stored in the memory of I&C systems, the operations of I&C systems on NPP components, and NPP processes. Reward rates and impulse rewards are defined in the SAN models based on the activity-marking reward structure to estimate NPP operation profiles. These profiles are then used to probabilistically estimate the legitimacy of the semantics and payloads of protocol frames received by I&C systems.

  19. Nuclear power plant cable materials :

    Energy Technology Data Exchange (ETDEWEB)

    Celina, Mathias Christopher; Gillen, Kenneth T; Lindgren, Eric Richard

    2013-05-01

    A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostly inert aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on

  20. TS Power Plant, Eureka County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, R. [DTE Energy Services (United States)

    2008-10-15

    Not all coal-fired power plants are constructed by investor-owned utilities or independent power producers selling to wholesale markets. When Newmont Mining Corp. recognised that local power supplies were inadequate and too expensive to meet long-term electricity needs for its major gold- and copper-mining operations in northern Nevada, it built its own generation. What is more, Newmont's privately owned 200-MW net coal-fired plant features power plant technologies that will surely become industry standards. Newmont's investment in power and technology is also golden: the capital cost will be paid back in about eight years. 4 figs.

  1. Stillwater Hybrid Geo-Solar Power Plant Optimization Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Daniel S.; Mines, Gregory L.; Turchi, Craig S.; Zhu, Guangdong; Cohan, Sander; Angelini, Lorenzo; Bizzarri, Fabrizio; Consoli, Daniele; De Marzo, Alessio

    2015-09-02

    The Stillwater Power Plant is the first hybrid plant in the world able to bring together a medium-enthalpy geothermal unit with solar thermal and solar photovoltaic systems. Solar field and power plant models have been developed to predict the performance of the Stillwater geothermal / solar-thermal hybrid power plant. The models have been validated using operational data from the Stillwater plant. A preliminary effort to optimize performance of the Stillwater hybrid plant using optical characterization of the solar field has been completed. The Stillwater solar field optical characterization involved measurement of mirror reflectance, mirror slope error, and receiver position error. The measurements indicate that the solar field may generate 9% less energy than the design value if an appropriate tracking offset is not employed. A perfect tracking offset algorithm may be able to boost the solar field performance by about 15%. The validated Stillwater hybrid plant models were used to evaluate hybrid plant operating strategies including turbine IGV position optimization, ACC fan speed and turbine IGV position optimization, turbine inlet entropy control using optimization of multiple process variables, and mixed working fluid substitution. The hybrid plant models predict that each of these operating strategies could increase net power generation relative to the baseline Stillwater hybrid plant operations.

  2. Nuclear Power Plant Module, NPP-1: Nuclear Power Cost Analysis.

    Science.gov (United States)

    Whitelaw, Robert L.

    The purpose of the Nuclear Power Plant Modules, NPP-1, is to determine the total cost of electricity from a nuclear power plant in terms of all the components contributing to cost. The plan of analysis is in five parts: (1) general formulation of the cost equation; (2) capital cost and fixed charges thereon; (3) operational cost for labor,…

  3. Nuclear Power Plant Lifetime Management Study (I)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yull; Jeong, Ill Seok; Jang, Chang Heui; Song, Taek Ho; Song, Woo Young [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company Consulting and Architecture Engineers, (Korea, Republic of); Kim, Woo Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    As the operation-year of nuclear power plant increases and finding sites for new nuclear power plant becomes harder, a comprehensive and systematic nuclear plant lifetime management(PLIM) program including life extension has to be established for stable and safe supply of electricity. A feasibility study was conducted to systematically evaluate technical, economic and regulatory aspect of plant lifetime managements and plant life extension for Kori-1 nuclear power plant. For technical evaluation of nuclear power plant, 13 major components were selected for lifetime evaluation by screening system. structure, and components(SSCs) of the plant. It was found that except reactor pressure vessel, which needs detailed integrity analysis, and low pressure turbine, which is scheduled to be replaced, 11 out of 13 major components have sufficient service life, for more than 40 years. Because domestic rules and regulations related to license renewal has not yet been written, review on the regulatory aspect of life extensions was conducted using US NRC rules and regulations. A cooperative effort with nuclear regulatory body is needed for early completion of license renewal rules and regulations. For economic evaluation of plant lifetime extension, a computer program was developed and used. It was found that 10 to 20 year of extension operation of Kori-1 nuclear power plant was proved. Based on the results, next phase of plant lifetime management program for detailed lifetime evaluation and presenting detailed implementation schedule for plant refurbishment for lifetime extension should be followed. (author). 74 refs., figs.

  4. Central receiver solar thermal power system. Phase 1. CDRL item 2; Pilot Plant preliminary design report. Volume II. System decription and system analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    An active system analysis and integration effort has been maintained. These activities have included the transformation of initial program requirements into a preliminary system design, the evolution of subsystem requirements which lay the foundation for subsystem design and test activity, and the overseeing of the final preliminary design effort to ensure that the subsystems are operationally compatible and capable of producing electricity at the lowest possible cost per unit of energy. Volume II of the Preliminary Design Report presents the results of the overall system effort that went on during this contract. The effort is assumed to include not only the total system definition and design but also all subsystem interactions.

  5. Ammonia in power plant emission

    Science.gov (United States)

    Hammerich, Mads; Henningsen, J. O.; Olafsson, Ari

    1990-08-01

    Ammonia monitoring is needed in most schemes for denitrification of power plant emission. In the PALAMON system we use a 500 MHz tunable, single mode, single line, CO2 laser as light source for a low pressure, high temperature, photoacoustic cell. With this cell we can resolve the sR(5,O) line of the ammonia spectrum, and suppress the interfering C02(9R30) absorption line down to a lppm NH3 detection limit. The validity of the measured ammonia concentrations is strongly dependent on details of the sampling system and on the reliability of the calibration routines. In particular calibration with certified mixtures of NH3:N2 has proved insufficient due to the multiple and long time constants caused by adsorption of ammonia to different materials in the system. Presence of water vapor in the gas greatly reduces these time constants. Therefore a number of methods for simple production of moist calibration gases from macroscopic amounts of NH3 are applied. The calibrations are translated to response from an easily managable absorber in order to allow automated recalibration of the photoacoustic response. Data from a field test of the system, and calibration data will be presented.

  6. 47 CFR 15.111 - Antenna power conduction limits for receivers.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Antenna power conduction limits for receivers... DEVICES Unintentional Radiators § 15.111 Antenna power conduction limits for receivers. (a) In addition to... CB receivers that provide terminals for the connection of an external receiving antenna may be...

  7. Lessons learned from existing biomass power plants

    Energy Technology Data Exchange (ETDEWEB)

    Wiltsee, G.

    2000-02-24

    This report includes summary information on 20 biomass power plants, which represent some of the leaders in the industry. In each category an effort is made to identify plants that illustrate particular points. The project experiences described capture some important lessons learned that lead in the direction of an improved biomass power industry.

  8. International seminar on biomass and fossil fuels co-firing in power plants and heating plants in Europe; Seminaire international sur la cocombustion de biomasse et d'energies fossiles dans les centrales electriques et les chaufferies en Europe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The aim of the European commission which has fixed to 12% the share of renewable energies in the total energy consumption up to 2010, is to develop the biomass sector. Co-firing is a solution that allows to increase significantly the use of biomass because it does not require important investments. Today, about 150 power plants in Europe use co-firing. An Altener project named 'Cofiring' has ben settled in order to bring together and analyze the European experience in this domain and to sustain and rationalize the design of future projects. The conclusions of this study, coordinated by VTT Energy and which involves CARMEN (Germany), CBE (Portugal), the Danish centre for landscape and planning, ITEBE (France), KOBA (Italy), SLU (Sweden), and EVA (Austria), were presented during this international seminar. (J.S.)

  9. Harmonics in a Wind Power Plant: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, V.; Madrigal, M.; Muljadi, E.; Gevorgian, V.

    2015-04-02

    Wind power generation has been growing at a very fast pace for the past decade, and its influence and impact on the electric power grid is significant. As in a conventional power plant, a wind power plant (WPP) must ensure that the quality of the power being delivered to the grid is excellent. At the same time, the wind turbine should be able to operate immune to small disturbances coming from the grid. Harmonics are one of the more common power quality issues presented by large WPPs because of the high switching frequency of the power converters and the possible nonlinear behavior from electric machines (generator, transformer, reactors) within a power plant. This paper presents a summary of the most important issues related to harmonics in WPPs and discusses practical experiences with actual Type 1 and Type 3 wind turbines in two WPPs.

  10. Dynamic Frequency Response of Wind Power Plants

    DEFF Research Database (Denmark)

    Altin, Müfit

    Electricity generation from wind energy has rapidly increased for the last five years worldwide. In many countries, wind energy targets have been set in the range of 20% to 50% of all electricity generation due to the concerns of CO2 emissions, fossil fuel costs, and energy efficiency. In order...... to maintain sustainable and reliable operation of the power system for these targets, transmission system operators (TSOs) have revised the grid code requirements. Also, the TSOs are planning the future development of the power system with various wind penetration scenarios to integrate more wind power...... according to their grid codes. In these scenarios particularly with high wind power penetration cases, conventional power plants (CPPs) such as old thermal power plants are planned to be replaced with wind power plants (WPPs). Consequently, the power system stability will be affected and the control...

  11. Research of the Power Plant Operational Modes

    Directory of Open Access Journals (Sweden)

    Koismynina Nina M.

    2017-01-01

    Full Text Available In this article the algorithm of the power plant operational modes research is offered. According to this algorithm the program for the modes analysis and connection power transformers choice is developed. The program can be used as educational means for studying of the power plant electric part, at the same time basic data are provided. Also the program can be used for the analysis of the working power plants modes. Checks of the entered data completeness and a choice correctness of the operational modes are provided in the program; in all cases of a deviation from the correct decisions to the user the relevant information is given.

  12. Hybrid wind-power-distillation plant

    Directory of Open Access Journals (Sweden)

    Ninić Neven

    2012-01-01

    Full Text Available This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen using less than 10% of the distillate produced.

  13. DIRECT FUEL/CELL/TURBINE POWER PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2004-05-01

    This report includes the progress in development of Direct FuelCell/Turbine{reg_sign} (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T power system is based on an indirectly heated gas turbine to supplement fuel cell generated power. The DFC/T power generation concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, 60% on coal gas, minimal emissions, simplicity in design, direct reforming internal to the fuel cell, reduced carbon dioxide release to the environment, and potential cost competitiveness with existing combined cycle power plants. FCE successfully completed testing of the pre-alpha DFC/T hybrid power plant. This power plant was constructed by integration of a 250kW fuel cell stack and a microturbine. The tests of the cascaded fuel cell concept for achieving high fuel utilizations were completed. The tests demonstrated that the concept results in higher power plant efficiency. Also, the preliminary design of a 40 MW power plant including the key equipment layout and the site plan was completed.

  14. Uranium contamination due to nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Martin Sanchez, A.; Vera Tome, F.; Diaz Bejarano, J.; Garcia Aparicio, A. (Univ. de Extremadura, Badajoz (Spain). Dept. de Fisica)

    1992-01-01

    Measurements of uranium isotopes and their daughters in the natural series were performed in the cooling reservoirs and their neighborhood of two nuclear power plants, [alpha] and [gamma] spectrometry of samples were used to measure the natural and artificial radionuclides. The nuclear power plants are in the southwest of Spain and one of them has been in operation since 1982, the other plant is in the construction phase. We compare the results obtained for the two sites. (orig.).

  15. Energetic behavior of a facility. Optical losses: Energetic behavior of a photovoltaic power plant; Centrales fotovoltaicas con sequimiento azimutal. Perdidas opticas: Comportamiento energetico de una instalacion

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.; Marroyo, L.; Lorenzo, E.; Perez, M.

    2009-07-01

    The quantity of radiation which reaches to the cells inside the photovoltaic modules is usually less than radiation received by on the surface of modules. this is mainly caused by accumulated dirtiness on referred surface (dust, pollution...) as well as losses produced by reflection and absorption in the cells cover materials. These reflection and absorption losses depend on the radiation incidence angle, and that is why they are normally known as angular losses. the angular losses tend to increase in the same proportion that increases uncleanness on the surface, and consequently it must be considered together with the ones occasioned by the mentioned uncleanness. Therefore, the term optical losses includes both types of losses, and the knowledge of the optical loss value is very important when we analyze the energetic behavior of a photovoltaic facility, and also when the prediction of this behavior is intended. (Author) 18 refs.

  16. Conformation of an evaluation process for a license renovation solicitude of a nuclear power plant in Mexico. Part 2; Conformacion de un proceso de evaluacion para una solicitud de renovacion de licencia de una central nuclear en Mexico. Parte 2

    Energy Technology Data Exchange (ETDEWEB)

    Serrano R, M. de L., E-mail: mlserrano@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    At the present time the operation licenses in force for the reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) will expire in the year 2020 and 2025 for the Unit-1 and Unit-2, respectively, for which the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) has begun its preparation to assist a solicitude of the licensee to continue the operation of the NPP-L V. The present work has the purpose of defining the steps to continue and to generate the documents that would help in this process, as the normative, guides, procedures, regulations, controls, etc. so that the evaluation process will be effective and efficient, as much for the regulator organ as for the licensee. The advance carried out in the continuation of the conformation of an evaluation process of license renovation solicitude is also exposed, taking like base the requirements established by the CNSNS, the regulator organ of the United States (US NRC), and the IAEA for license renovation solicitude of this type. A summary of the licenses granted from the beginning of commercial operation of the NPP-L V is included, both units and the amendments to these licenses, explaining the reason of the amendment shortly and in the dates they were granted. A brief exposition of the nuclear power plants to world level that have received extension of its operation is included. The normative that can be applied in a life extension evaluation is presented, the evaluation process to continue with the guides of the US NRC, the reach of the evaluation and the minimum information required to the licensee that should accompany to their solicitude. (author)

  17. Hydraulic Power Plant Machine Dynamic Diagnosis

    Directory of Open Access Journals (Sweden)

    Hans Günther Poll

    2006-01-01

    Full Text Available A method how to perform an entire structural and hydraulic diagnosis of prototype Francis power machines is presented and discussed in this report. Machine diagnosis of Francis units consists on a proper evaluation of acquired mechanical, thermal and hydraulic data obtained in different operating conditions of several rotary and non rotary machine components. Many different physical quantities of a Francis machine such as pressure, strains, vibration related data, water flow, air flow, position of regulating devices and displacements are measured in a synchronized way so that a relation of cause an effect can be developed for each operating condition and help one to understand all phenomena that are involved with such kind of machine. This amount of data needs to be adequately post processed in order to allow correct interpretation of the machine dynamics and finally these data must be compared with the expected calculated data not only to fine tuning the calculation methods but also to accomplish fully understanding of the influence of the water passages on such machines. The way how the power plant owner has to operate its Francis machines, many times also determined by a central dispatcher, has a high influence on the fatigue life time of the machine components. The diagnostic method presented in this report helps one to understand the importance of adequate operation to allow a low maintenance cost for the entire power plant. The method how to acquire these quantities is discussed in details together with the importance of correct sensor balancing, calibration and adequate correlation with the physical quantities. Typical results of the dynamic machine behavior, with adequate interpretation, obtained in recent measurement campaigns of some important hydraulic turbines were presented. The paper highlights the investigation focus of the hydraulic machine behavior and how to tailor the measurement strategy to accomplish all goals. Finally some

  18. Reliability of emergency ac power systems at nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Battle, R E; Campbell, D J

    1983-07-01

    Reliability of emergency onsite ac power systems at nuclear power plants has been questioned within the Nuclear Regulatory Commission (NRC) because of the number of diesel generator failures reported by nuclear plant licensees and the reactor core damage that could result from diesel failure during an emergency. This report contains the results of a reliability analysis of the onsite ac power system, and it uses the results of a separate analysis of offsite power systems to calculate the expected frequency of station blackout. Included is a design and operating experience review. Eighteen plants representative of typical onsite ac power systems and ten generic designs were selected to be modeled by fault trees. Operating experience data were collected from the NRC files and from nuclear plant licensee responses to a questionnaire sent out for this project.

  19. Impact of Aerosols on Atmospheric Attenuation Loss in Central Receiver Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Sengupta, M.; Wagner, M. J.

    2011-08-01

    Atmospheric attenuation loss between the heliostat field and receiver has been recognized as a significant source of loss in Central Receiver Systems. In clear sky situations, extinction of Direct Normal Irradiance (DNI) is primarily by aerosols in the atmosphere. When aerosol loading is high close to the surface the attenuation loss between heliostat and receivers is significantly influenced by the amount of aerosols present on a particular day. This study relates measured DNI to aerosol optical depths close to the surface of the earth. The model developed in the paper uses only measured DNI to estimate the attenuation between heliostat and receiver in a central receiver system. The requirement that only a DNI measurement is available potentially makes the model a candidate for widespread use.

  20. Projected techno-economic improvements for advanced solar thermal power plants

    Science.gov (United States)

    Fujita, T.; Manvi, R.; Roschke, E. J.

    1979-01-01

    The projected characteristics of solar thermal power plants (with outputs up to 10 MWe) employing promising advanced technology subsystems/components are compared to current (or pre-1985) steam-Rankine systems. Improvements accruing to advanced technology development options are delineated. The improvements derived from advanced systems result primarily from achieving high efficiencies via solar collector systems which (1) capture a large portion of the available insolation and (2) concentrate this captured solar flux to attain high temperatures required for high heat engine/energy conversion performance. The most efficient solar collector systems employ two-axis tracking. Attractive systems include the central receiver/heliostat and the parabolic dish.

  1. Photovoltaic power plants: production calculation

    Energy Technology Data Exchange (ETDEWEB)

    Cirillo, E.; Lazzarin, R.

    Rational sizing of a photovoltaic plant requires a good evaluation of the obtainable electric energy as a function of the many meteorological and plant parameters. A computing procedure is described in detail together with a fully developed numerical example. The procedure is based on monthly usability. It is reliable and it allows designers to take into account the influence of the main plant parameters within rather wide ranges.

  2. Central solar heating plants with seasonal storage

    Energy Technology Data Exchange (ETDEWEB)

    Breger, D.S.; Sunderland, J.E.

    1989-03-01

    The University of Massachusetts has recently started a two year effort to identify and design a significant Central Solar Heating Plant with Seasonal Storage (CSHPSS) in Massachusetts. The work is closely associated with the U.S. participation in the International Energy Agency (IEA) Task on CSHPSS. The University is working closely with the Commonwealth of Massachusetts to assist in identifying State facilities as potential sites and to explore and secure State support which will be essential for product development after the design phase. Currently, the primary site is the University of Massachusetts, Amherst campus with particular interest in several large buildings which are funded for construction over the next 4-5 years. Seasonal thermal energy storage will utilize one of several geological formations.

  3. Model Predictive Control of Integrated Gasification Combined Cycle Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    B. Wayne Bequette; Priyadarshi Mahapatra

    2010-08-31

    The primary project objectives were to understand how the process design of an integrated gasification combined cycle (IGCC) power plant affects the dynamic operability and controllability of the process. Steady-state and dynamic simulation models were developed to predict the process behavior during typical transients that occur in plant operation. Advanced control strategies were developed to improve the ability of the process to follow changes in the power load demand, and to improve performance during transitions between power levels. Another objective of the proposed work was to educate graduate and undergraduate students in the application of process systems and control to coal technology. Educational materials were developed for use in engineering courses to further broaden this exposure to many students. ASPENTECH software was used to perform steady-state and dynamic simulations of an IGCC power plant. Linear systems analysis techniques were used to assess the steady-state and dynamic operability of the power plant under various plant operating conditions. Model predictive control (MPC) strategies were developed to improve the dynamic operation of the power plants. MATLAB and SIMULINK software were used for systems analysis and control system design, and the SIMULINK functionality in ASPEN DYNAMICS was used to test the control strategies on the simulated process. Project funds were used to support a Ph.D. student to receive education and training in coal technology and the application of modeling and simulation techniques.

  4. Technological evaluation for the extension of the operation license to the nuclear power plant of Laguna Verde; Evaluacion tecnologica para la extension de la licencia de operacion de la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C. R.; Medina A, A. L., E-mail: carlos.arganis@inin.gob.m [ININ, Departamento de Tecnologia de Materiales, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-07-01

    At the present time one of the tendencies in the nuclear industry is the renovation of operation licenses of the nuclear power plants, with the purpose of prolonging their operation 20 years more than the time settled down in their original license, which is of 30 years for the case of the nuclear power plant of Laguna Verde. This allows the electric power generation for a major period of time and to a relatively low price, giving this way a bigger competitiveness to the power stations of nuclear power. However, to request the license extension of the nuclear power plant requires to get ready the documentation and necessary studies for: to maintain a high level of security, to optimize the operation, maintenance and service life of the structures, systems and components, to maintain an acceptable level of performance, to maximize the recovery of the investment about the service of the nuclear power plant and to preserve the sure conditions for a major operation period at the license time. This paper describes the studies conducted by the Materials Technology Department of the Instituto Nacional de Investigaciones Nucleares (ININ) to substantiate the required documentation for obtaining the extension of operating license of the nuclear power plant. These studies are focused mainly in the reactor pressure vessels of both units, as well as in the deposit of noble metals and the influence of the sludges (crud s) in this deposit. (Author)

  5. Direct flash steam geothermal power plant assessment

    Science.gov (United States)

    Alt, T. E.

    1982-01-01

    The objective was to analyze the capacity and availability factors of an operating direct flash geothermal power plant. System and component specifications, operating procedures, maintenance history, malfunctions, and outage rate are discussed. The plant studied was the 75 MW(e) geothermal power plant at Cerro Prieto, Mexico, for the years 1973 to 1979. To describe and assess the plant, the project staff reviewed documents, visited the plant, and met with staff of the operating utility. The high reliability and availability of the plant was documented and actions responsible for the good performance were identified and reported. The results are useful as guidance to US utilities considering use of hot water geothermal resources for power generation through a direct flash conversion cycle.

  6. Study of environmental noise in a BWR plant like the Nuclear Power Plant Laguna Verde; Estudio de ruido ambiental en una planta BWR como la Central Nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Cruz G, M.; Amador C, C., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    In all industry type the health costs generated by the noise are high, because the noise can cause nuisance and to harm the capacity to work when causing tension and to perturb the concentration, and in more severe cases to reach to lose the sense of the hearing in the long term. The noise levels in the industry have been designated for the different types of use like residential, commercial, and industrial and silence areas. The noise can cause accidents when obstructing the communications and alarm signs. For this reason the noise should be controlled and mitigated, at a low level as reasonably is possible, taking into account that the noise is an acoustic contamination. The present study determines a bases line of the environmental noise levels in a nuclear power plant BWR-5 as Laguna Verde, (like reference) to be able to determine and to give pursuit to the possible solutions to eliminate or to limit the noise level in the different job areas. The noise levels were registered with a meter of integrative noise level (sonometer) and areas of noise exposure levels mapping the general areas in the buildings were established, being the registered maximum level of 96.94 dba in the building of the Reactor-elevation 0.65 m under the operation conditions of Extended Power Up rate (EPU) of 120% PTN. Knowing that the exposition to noises and the noise dose in the job place can influence in the health and in the safety of the workers, are extensive topics that they should be analyzed for separate as they are: to) the effects in the health of the exposure to the noise, b) how measuring the noise, c) the methods and technologies to combat and to control the noise in the industry by part of engineering area and d) the function of the industrial safety bodies as delegates of the health and safety in the task against the noise in the job. (author)

  7. Emotional consequences of nuclear power plant disasters.

    Science.gov (United States)

    Bromet, Evelyn J

    2014-02-01

    The emotional consequences of nuclear power plant disasters include depression, anxiety, post-traumatic stress disorder, and medically unexplained somatic symptoms. These effects are often long term and associated with fears about developing cancer. Research on disasters involving radiation, particularly evidence from Chernobyl, indicates that mothers of young children and cleanup workers are the highest risk groups. The emotional consequences occur independently of the actual exposure received. In contrast, studies of children raised in the shadows of the Three Mile Island (TMI) and Chernobyl accidents suggest that although their self-rated health is less satisfactory than that of their peers, their emotional, academic, and psychosocial development is comparable. The importance of the psychological impact is underscored by its chronicity and by several studies showing that poor mental health is associated with physical health conditions, early mortality, disability, and overuse of medical services. Given the established increase in mental health problems following TMI and Chernobyl, it is likely that the same pattern will occur in residents and evacuees affected by the Fukushima meltdowns. Preliminary data from Fukushima indeed suggest that workers and mothers of young children are at risk of depression, anxiety, psychosomatic, and post-traumatic symptoms both as a direct result of their fears about radiation exposure and an indirect result of societal stigma. Thus, it is important that non-mental health providers learn to recognize and manage psychological symptoms and that medical programs be designed to reduce stigma and alleviate psychological suffering by integrating psychiatric and medical treatment within the walls of their clinics.Introduction of Emotional Consequences of Nuclear Power Plant Disasters (Video 2:15, http://links.lww.com/HP/A34).

  8. Understanding the corrosion phenomena to organize the nondestructive evaluation programs in the nuclear power plants; Connaitre les phenomenes de corrosion pour organiser les programmes d'end dans les centrales nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Berge, J.Ph. [Federation Europeenne de Corrosion, 75 - Paris (France); Samman, J. [Electricite de France (EDF), Div. du Production Nucleaire, 75 - Paris (France)

    2001-07-01

    The french nuclear power plants used PWR which components revealed many corrosion defects of different shapes as stress corrosion cracks or pits. Understanding the corrosion processes will help the inspection of in service power plants. The following examples describe some corrosion cases and present the corresponding developed control methods: corrosion on condenser, secondary circuit pipes and corrosion-erosion, steam generator pipes, vessels head penetration. (A.L.B.)

  9. Light-receiving characteristics of a distributed solar module with a plant shoot configuration

    Energy Technology Data Exchange (ETDEWEB)

    Obara, Shin' ya; Tanno, Itaru; Shiratori, Taichiro [Department of Mechanical Engineering, Tomakomai National College of Technology, Nishikioka 443, Tomakomai, Hokkaido 0591275 (Japan)

    2009-05-15

    The object of this study is to develop a solar power generation system with high energy density. In order to improve the energy density of a solar power generation system, compaction of the system (improvement of light-receiving density) and a directive fall (dependency on the solar position is excluded) are required. So, in this study, because the issues described above are resolved, a solar cell module is divided and distributed. In this paper, the relation between the shoot shape of a 'dogwood tree,' 'ginkgo tree,' 'Dendropanax trifidus,' and 'Acer palmatum var. matsumurae' and the light-receiving amount is clarified by numerical analysis, and the optimal solution of each shoot shape and result of the light-receiving density were obtained. Furthermore, the characteristics of variables, such as leaf size, installation location, length of the branch of a leaf, and light-receiving amount of each shoot, were examined. As a result, in the distribution of the solar cell module with the shoot shape of each plant except dogwood, the light-receiving density showed clear improvement compared with the distribution of a square module. Compared with a square leaf, the maximum differences of each light-receiving density of D. trifidus, ginkgo, and A. palmatum var. matsumurae were 2.0 times, 7.4 times, and 6.4 times in January, respectively. On the other hand, they were 1.9 times, 8.7 times, and 7.3 times in July. (author)

  10. Feasibility study for the installation of a small hydro electric power plant; Etude de faisabilite. Petite centrale hydro-electrique au lieu dit 'Sous les Roches' a Sonceboz

    Energy Technology Data Exchange (ETDEWEB)

    Tissot, N. [MHyLab, Mini-Hydraulics Laboratory, Montcherand (Switzerland); Hausmann, H. [Hans Hausmann, Bevilard (Switzerland)

    2003-07-01

    This report for the Swiss Federal Office of Energy presents a technical, economical and ecological analysis of the feasibility of a small hydroelectric power plant at Sonceboz, in the Swiss Jura mountains. The power of the planed plant would typically be 500 kW for a water head of about 10 m. The study shows that, compared to one single turbine, a pair of Kaplan type turbines would be operational over a larger range of the river's water flow rate. This solution would be a little bit more costly but offer more flexibility for maintenance. Two maximum water flow rates are considered, 4.5 and 6 m{sup 3}/s respectively. According to the economical study, done with current electric kWh prices, both configurations are viable while the largest flow rate leads to a larger profit. The report is rounded up by a sensitivity analysis considering variations in annual power generation, electro-mechanical and construction cost as well as turbine efficiency. It indicates that this last factor could be crucial for the overall profitability. [French] Ce rapport est le resultat detaille de l'analyse technico-economique et ecologique de faisabilite de la realisation d'une petite centrale hydroelectrique basse chute qui pourrait exploiter une denivellation d'environ 10 m pour une puissance de l'ordre de 500 kW pres de Sonceboz dans le Jura suisse. L'etude montre que le couplage de deux turbines Kaplan offrirait une possibilite de fonctionnement sur une plus grande plage de flux ainsi qu'une plus grande flexibilite de maintenance, ceci pour un cout legerement superieur a l'option a une seule turbine. Les debits de 4.5 et 6 m{sup 3}/s sont consideres. L'etude economique montre que le debit de 6 m{sup 3}/s est plus rentable au prix de vente actuel du kWh. L'article se termine par une analyse de sensibilite sur les incertitudes concernant la production annuelle, les prix de l'electromecanique et du genie civil et le rendement des

  11. 76 FR 1469 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-01-10

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2... Cliffs Nuclear Power Plant, LLC, the licensee, for operation of the Calvert Cliffs Nuclear Power Plant..., Calvert Cliffs Nuclear Power Plant (NUREG-1437, Supplement 1), dated......

  12. Current fusion power plant design concepts

    Energy Technology Data Exchange (ETDEWEB)

    Gore, B.F.; Murphy, E.S.

    1976-09-01

    Nine current U.S. designs for fusion power plants are described in this document. Summary tabulations include a tenth concept, for which the design document was unavailable during preparation of the descriptions. The information contained in the descriptions was used to define an envelope of fusion power plant characteristics which formed the basis for definition of reference first commercial fusion power plant design. A brief prose summary of primary plant features introduces each of the descriptions contained in the body of this document. In addition, summary tables are presented. These tables summarize in side-by-side fashion, plant parameters, processes, combinations of materials used, requirements for construction materials, requirements for replacement materials during operation, and production of wastes.

  13. EPA Facility Registry Service (FRS): Power Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on power plants, based on the Energy Information Administration's EIA-860 dataset and supplemented with data from EPA's Facility...

  14. Experimentation of RT-LOTOS for a critical function of a power plant instrumentation and control system; Experimentation de RT-LOTOS pour une fonction critique d`un systeme de controle-commande en centrale

    Energy Technology Data Exchange (ETDEWEB)

    Andriantsiiferana, L.; Courtiat, J.P.; De Oliveira, R.C.

    1996-01-01

    This document is the final report of the contract between LAAS-CNRS and the EdF Direction of Researches and Studies about the experimentation of RT-LOTOS formal description technique on a critical function of a nuclear power plant instrumentation and control system. This report comprises 4 parts: part 1 describes the RT-LOTOS (Real Time-Language of Temporal Ordering Specifications) tutorial and its RTL tool environment, the different RT-LOTOS operators and semantics, and the RTL tool main functionalities; part 2 deals with the methodology and the global architecture for the specification and validation of the CCT (Central Calculator for Treatment); part 3 gives more details about the different processes identified in the specification architecture and presents the main results obtained for the validation of the nominal functioning; part 4 describes some exceptional situations and shows how some failures and their associated recovery mechanisms can be modelled. (J.S.). 6 refs., 53 figs., 5 tabs., 2 appends.

  15. Starting of the steam generator of a fossil fuel power plant, using predictive control based in a neuronal model; Arranque del generador de vapor de una central termoelectrica, usando control predictivo basado en un modelo neuronal

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo Dominguez, Tonatiuh

    2004-09-15

    In this thesis work it is presented the design and implementation of a simulator of total scope of a predictive controller based in the neuronal model of the temperature in two stages of the heating of the steam generator of a fossil fuel power plant. An implemented control scheme is detailed, as well as the methodology for the identification of a neuronal model utilized for the control. Finally the results of the implementation in the simulator located at the Instituto de Investigaciones Electricas (IIE) are shown to be satisfactory. This control structure is not applied directly in closed circuit, but provides the value of the control actions to a human operator. [Spanish] En este trabajo de tesis se presenta el diseno e implementacion, en un simulador de alcance total, de un controlador predictivo basado en un modelo neuronal para el control de la temperatura en dos etapas del calentamiento del generador de vapor de una central termoelectrica. Se detalla el esquema de control implementado, asi como la metodologia de identificacion de un modelo neuronal utilizado para la sintesis del control. Finalmente se muestran los resultados de la implementacion en el simulador que se encuentra en el Instituto de Investigaciones Electricas (IIE); dichos resultados fueron satisfactorios. Esta estructura de control no se aplica directamente en lazo cerrado, sino que provee el valor de las acciones de control a un operador humano.

  16. Report of the national committee on the evaluation of special water releases for electric power plants; Rapport du Comite national de suivi des rejets d'eau exceptionnels des centrales de production d'electricite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    During summer 2003, because of high temperatures monitored in french rivers and to guarantee the electric power supply in France, the government authorized some power plants of EDF to depart from the rules normally applied in terms of release temperatures of cooling water in rivers. This report presents the main observations realized by the Committee responsible of the electric power plants control on the ecological impacts, the prevention means and the crisis management bound to the meteorological phenomena and the consequences on the water policy. (A.L.B.)

  17. Topologies for large scale photovoltaic power plants

    OpenAIRE

    Cabrera Tobar, Ana; Bullich Massagué, Eduard; Aragüés Peñalba, Mònica; Gomis Bellmunt, Oriol

    2016-01-01

    © 2016 Elsevier Ltd. All rights reserved. The concern of increasing renewable energy penetration into the grid together with the reduction of prices of photovoltaic solar panels during the last decade have enabled the development of large scale solar power plants connected to the medium and high voltage grid. Photovoltaic generation components, the internal layout and the ac collection grid are being investigated for ensuring the best design, operation and control of these power plants. This ...

  18. Efficiencies of Power Plants Using Hydrothermal Oxidation

    Science.gov (United States)

    Hirosaka, Kazuma; Yuvamitra, Korakot; Ishikawa, Akira; Hasegawa, Tatsuya

    Wet biomass is hard to handle as a fuel for power plants because it contains high moisture and its drying process needs more energy input than it produces. Hydrothermal oxidation could be one of the promising technologies to overcome this problem because this process does not need drying process at all. We focus on recovery of thermal energy produced by hydrothermal oxidation of wet biomass. Two kinds of power plant are investigated, a direct type and an indirect type. In the direct type power plant, reactant is oxidized in a reactor and directly flowed into a turbine. In the indirect type power plant, reactant is oxidized in a reactor and the reaction heat is conveyed to the main water, which is flowed into a turbine. The amount of electric power and the energy conversion efficiency are calculated by using ethanol, glucose and peat solutions as reactants. In both type of power plant, one steam turbine is employed for generating electricity with the maximum turbine inlet temperature of 650 °C. As ethanol concentration increased, the amount of electric power and the energy conversion efficiency become higher. The maximum efficiency for the direct type power plant using ethanol solution is about 26.4 % for 17.6 wt% at the reactor pressure of 10 MPa. The efficiency of the indirect type power plant is much lower than that of the direct type, but by pressurizing main water up to 4 MPa, the efficiency becomes higher up to 20.9 %. For glucose solution, the maximum efficiency for the direct type is about 25.5 % for 34.5 wt% at the reactor pressure of 5 MPa. The maximum efficiency of the indirect type at the main water pressure of 4 MPa is about 21.1 % for 40.7 wt%. For peat solution, only the indirect type is investigated. The maximum efficiency at the main water pressure of 4 MPa is about 20.8 % for 36.8 wt%.

  19. Market Integration of Virtual Power Plants

    DEFF Research Database (Denmark)

    Petersen, Mette Kirschmeyer

    Global efforts to reduce emissions of carbon dioxide drives the introduction of renewable power production technologies into the existing power system. The real-time balance between production and consumption must, however, still be maintained at all times. Unfortunately, this is becoming...... increasingly challenging due to the intrinsic variability of production technologies such as photovoltaics and wind turbines. In a Smart Grid system the balancing task will therefore be handled by mobilizing flexibility on the consumption side. This Thesis assumes that the Smart Grid should be commercially...... based rather than funded by subsidies. Consequently the Smart Grid provides a business opportunity for so-called Virtual Power Plants. A Virtual Power Plant is an independent commercial operator, which provides Smart Grid capabilities to flexible consumers. This means that the Virtual Power Plant...

  20. Comparison of large central and small decentralized power generation in India

    Energy Technology Data Exchange (ETDEWEB)

    None

    1997-05-01

    This reports evaluates two options for providing reliable power to rural areas in India. The benefits and costs are compared for biomass based distributed generation (DG) systems versus a 1200-MW central grid coal-fired power plant. The biomass based DG systems are examined both as alternatives to grid extension and as supplements to central grid power. The benefits are divided into three categories: those associated with providing reliable power from any source, those associated specifically with biomass based DG technology, and benefits of a central grid coal plant. The report compares the estimated delivered costs of electricity from the DG systems to those of the central plant. The analysis includes estimates for a central grid coal plant and four potential DG system technologies: Stirling engines, direct-fired combustion turbines, fuel cells, and biomass integrated gasification combined cycles. The report also discusses issues affecting India`s rural electricity demand, including economic development, power reliability, and environmental concerns. The results of the costs of electricity comparison between the biomass DG systems and the coal-fired central grid station demonstrated that the DG technologies may be able to produce very competitively priced electricity by the start of the next century. The use of DG technology may provide a practical means of addressing many rural electricity issues that India will face in the future. Biomass DG technologies in particular offer unique advantages for the environment and for economic development that will make them especially attractive. 58 refs., 31 figs.

  1. OUT Success Stories: Solar Trough Power Plants

    Science.gov (United States)

    Jones, J.

    2000-08-01

    The Solar Electric Generating System (SEGS) plants use parabolic-trough solar collectors to capture the sun's energy and convert it to heat. The SEGS plants range in capacity from 13.8 to 80 MW, and they were constructed to meet Southern California Edison Company's periods of peak power demand.

  2. Evaluation of Hybrid Power Plants using Biomass, Photovoltaics and Steam Electrolysis for Hydrogen and Power Generation

    Science.gov (United States)

    Petrakopoulou, F.; Sanz, J.

    2014-12-01

    Steam electrolysis is a promising process of large-scale centralized hydrogen production, while it is also considered an excellent option for the efficient use of renewable solar and geothermal energy resources. This work studies the operation of an intermediate temperature steam electrolyzer (ITSE) and its incorporation into hybrid power plants that include biomass combustion and photovoltaic panels (PV). The plants generate both electricity and hydrogen. The reference -biomass- power plant and four variations of a hybrid biomass-PV incorporating the reference biomass plant and the ITSE are simulated and evaluated using exergetic analysis. The variations of the hybrid power plants are associated with (1) the air recirculation from the electrolyzer to the biomass power plant, (2) the elimination of the sweep gas of the electrolyzer, (3) the replacement of two electric heaters with gas/gas heat exchangers, and (4) the replacement two heat exchangers of the reference electrolyzer unit with one heat exchanger that uses steam from the biomass power plant. In all cases, 60% of the electricity required in the electrolyzer is covered by the biomass plant and 40% by the photovoltaic panels. When comparing the hybrid plants with the reference biomass power plant that has identical operation and structure as that incorporated in the hybrid plants, we observe an efficiency decrease that varies depending on the scenario. The efficiency decrease stems mainly from the low effectiveness of the photovoltaic panels (14.4%). When comparing the hybrid scenarios, we see that the elimination of the sweep gas decreases the power consumption due to the elimination of the compressor used to cover the pressure losses of the filter, the heat exchangers and the electrolyzer. Nevertheless, if the sweep gas is used to preheat the air entering the boiler of the biomass power plant, the efficiency of the plant increases. When replacing the electric heaters with gas-gas heat exchangers, the

  3. Continental Airlines Receives J.D. Power and Associates Award

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ On June 29, 2006, Continental Airlines (NYSE: CAL) was ranked the highest in Customer Satisfaction Among Traditional Network Carriers in North America in the J.D.Power and Associates 2006 Airline Satisfaction Index StudySM.

  4. Informatization of Power Plant and Its Implementation

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhenghai

    2006-01-01

    @@ This paper presents the working procedure of power generating enterprises and explains the framework of an e-power-plant and its information system, puts forward the guideline and the general goal of informatization construction while focusing on the construction goal in the applied system, the implementing strategy, the project management and organization.

  5. Questions and Answers About Nuclear Power Plants.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    This pamphlet is designed to answer many of the questions that have arisen about nuclear power plants and the environment. It is organized into a question and answer format, with the questions taken from those most often asked by the public. Topics include regulation of nuclear power sources, potential dangers to people's health, whether nuclear…

  6. Occupational Exposure at a Contemplated Belarussian Power Plant Fired with Contaminated Biomass

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, K.G.; Fogh, C.L.; Roed, J

    1999-07-01

    To meet the current demand in Belarus for remediation of the vast forest areas that were contaminated by the Chernobyl accident and at the same time establish a much needed energy production, applying contaminated forest biomass as fuel in special power plants is being considered. This paper focuses on the radiation doses that may be received by workers at such a power plant. By Monte Carlo modelling based on a Danish biofuel power plant design it was found that the highest dose rates within the power plant would be those to people standing near the fly ash silo, bottom ash containers and so-called 'big bags' filled with fly ash waste. Inhalation doses were estimated to be low. External doses received while working at the power plant do not appear to be highly significant compared with the doses from environmental contamination in the area where the power plant is expected to be constructed. (author)

  7. Advanced coal-fired power plant technology

    Energy Technology Data Exchange (ETDEWEB)

    Klauke, F. [Babcock Borsig Power Energy GmbH (Germany)

    2001-07-01

    This paper presents the joint efforts of a large European group of manufacturers, utilities and institutes co-operating in a phased long-term project named 'Advanced 700{degree}C PF Power Plant'. Net efficiences of more than 50% will be reached through development of a super critical steam cycle operating at maximum steam temperatures in the range of 700{degree}C. The principal efforts are based on development of creep resistent nickel-based materials named super-alloys for the hottest areas of the water/steam cycle. The Advanced 700{degree}C PF Power Plant project will improve the competitiveness of coal-fired power generation. Furthermore, it will provide a major reduction of CO{sub 2} from coal-fired power plants in the range of 15% from the best PF power plants presently and up to 40% from older plants. The demonstration programme will leave the possibility of any plant output between 400 and 1000 MW. The project will run to the end of 2003. 8 figs.

  8. Quantitative assessment of aquatic impacts of power plants

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Arnold, E.M.; Skalski, J.R.; Fickeisen, D.H.; Baker, K.S.

    1979-08-01

    Progress is reported in a continuing study of the design and analysis of aquatic environmental monitoring programs for assessing the impacts of nuclear power plants. Analysis of data from Calvert Cliffs, Pilgrim, and San Onofre nuclear power plants confirmed the generic applicability of the control-treatment pairing design suggested by McKenzie et al. (1977). Substantial progress was made on the simulation model evaluation task. A process notebook was compiled in which each model equation was translated into a standardized notation. Individual model testing and evaluating was started. The Aquatic Generalized Environmental Impact Simulator (AGEIS) was developed and will be tested using data from Lake Keowee, South Carolina. Further work is required to test the various models and perfect AGEIS for impact analyses at actual power plant sites. Efforts on the hydrologic modeling task resulted in a compendium of models commonly applied to nuclear power plants and the application of two well-received hydrodynamic models to data from the Surry Nuclear Power Plant in Virginia. Conclusions from the study of these models indicate that slight inaccuracies of boundary data have little influence on mass conservation and accurate bathymetry data are necessary for conservation of mass through the model calculations. The hydrologic modeling task provides valuable reference information for model users and monitoring program designers.

  9. Perspectives on Magnetized Target Fusion Power Plants

    Science.gov (United States)

    Miller, R. L.

    2007-06-01

    One approach to Magnetized Target Fusion (MTF) builds upon the ongoing experimental effort (FRX-L) to generate a Field Reversed Configuration (FRC) target plasma suitable for translation and cylindrical-liner (i.e., converging flux conserver) implosion. Numerical modeling is underway to elucidate key performance drivers for possible future power-plant extrapolations. The fusion gain, Q (ratio of DT fusion yield to the sum of initial liner kinetic energy plus plasma formation energy), sets the power-plant duty cycle for a nominal design electric power [ e.g. 1,000 MWe(net)]. A pulsed MTF power plant of this type derives from the historic Fast Liner Reactor (FLR) concept and shares attributes with the recent Inertial Fusion Energy (IFE) Z-pinch and laser-driven pellet HYLIFE-II conceptual designs.

  10. Monitoring Biological Activity at Geothermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pryfogle

    2005-09-01

    The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has been evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.

  11. Integration of torrefaction with steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zakri, B.; Saari, J.; Sermyagina, E.; Vakkilainen, E.

    2013-09-01

    Torrefaction is one of the pretreatment technologies to enhance the fuel characteristics of biomass. The efficient and continuous operation of a torrefaction reactor, in the commercial scale, demands a secure biomass supply, in addition to adequate source of heat. Biorefinery plants or biomass-fuelled steam power plants have the potential to integrate with the torrefaction reactor to exchange heat and mass, using available infrastructure and energy sources. The technical feasibility of this integration is examined in this study. A new model for the torrefaction process is introduced and verified by the available experimental data. The torrefaction model is then integrated in different steam power plants to simulate possible mass and energy exchange between the reactor and the plants. The performance of the integrated plant is investigated for different configurations and the results are compared. (orig.)

  12. Direct FuelCell/Turbine Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2008-09-30

    This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply

  13. Optimal concentration and temperatures of solar thermal power plants

    OpenAIRE

    2012-01-01

    Using simple, finite-time, thermodynamic models of solar thermal power plants, the existence of an optimal solar receiver temperature has previously been demonstrated in literature. Scant attention has been paid, however, to the presence of an optimal level of solar concentration at which the conversion of incident sunlight to electricity (solar-to-electric efficiency) is maximized. This paper addresses that gap. The paper evaluates the impact, on the design of Rankine-cycle solar-trough and ...

  14. Global thermal pollution of rivers from thermoelectric power plants

    OpenAIRE

    Raptis, C.E.; Vliet, van, Hans; Pfister, S.

    2016-01-01

    Worldwide riverine thermal pollution patterns were investigated by combining mean annual heat rejection rates from power plants with once-through cooling systems with the global hydrological-water temperature model variable infiltration capacity (VIC)-RBM. The model simulates both streamflow and water temperature on 0.5° ×0.5° spatial resolution worldwide and by capturing their effect, identifies multiple thermal pollution hotspots. The Mississippi receives the highest total amount of heat em...

  15. Nuclear power plant security assessment technical manual.

    Energy Technology Data Exchange (ETDEWEB)

    O' Connor, Sharon L.; Whitehead, Donnie Wayne; Potter, Claude S., III

    2007-09-01

    This report (Nuclear Power Plant Security Assessment Technical Manual) is a revision to NUREG/CR-1345 (Nuclear Power Plant Design Concepts for Sabotage Protection) that was published in January 1981. It provides conceptual and specific technical guidance for U.S. Nuclear Regulatory Commission nuclear power plant design certification and combined operating license applicants as they: (1) develop the layout of a facility (i.e., how buildings are arranged on the site property and how they are arranged internally) to enhance protection against sabotage and facilitate the use of physical security features; (2) design the physical protection system to be used at the facility; and (3) analyze the effectiveness of the PPS against the design basis threat. It should be used as a technical manual in conjunction with the 'Nuclear Power Plant Security Assessment Format and Content Guide'. The opportunity to optimize physical protection in the design of a nuclear power plant is obtained when an applicant utilizes both documents when performing a security assessment. This document provides a set of best practices that incorporates knowledge gained from more than 30 years of physical protection system design and evaluation activities at Sandia National Laboratories and insights derived from U.S. Nuclear Regulatory Commission technical staff into a manual that describes a development and analysis process of physical protection systems suitable for future nuclear power plants. In addition, selected security system technologies that may be used in a physical protection system are discussed. The scope of this document is limited to the identification of a set of best practices associated with the design and evaluation of physical security at future nuclear power plants in general. As such, it does not provide specific recommendations for the design and evaluation of physical security for any specific reactor design. These best practices should be applicable to the design and

  16. Nuclear Security for Floating Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Skiba, James M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Scherer, Carolynn P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-13

    Recently there has been a lot of interest in small modular reactors. A specific type of these small modular reactors (SMR,) are marine based power plants called floating nuclear power plants (FNPP). These FNPPs are typically built by countries with extensive knowledge of nuclear energy, such as Russia, France, China and the US. These FNPPs are built in one country and then sent to countries in need of power and/or seawater desalination. Fifteen countries have expressed interest in acquiring such power stations. Some designs for such power stations are briefly summarized. Several different avenues for cooperation in FNPP technology are proposed, including IAEA nuclear security (i.e. safeguards), multilateral or bilateral agreements, and working with Russian design that incorporates nuclear safeguards for IAEA inspections in non-nuclear weapons states

  17. The French Electricity Company (EDF) and GEC ALSTHOM have signed the agreement for Chinese Laibin B electric power plant; Electricite de France (EDF) et GEC ALSTHOM signent l'accord de la centrale electrique de Laibin B en Chine

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-03

    EDF and GEC ALSTHOM together with the government of Chinese Province Guangxi have organized in Pekin on 3 september 1997 a ceremony for signing a BOOT (Build, Own, Operate, Transfer) contract for the Coal Power Plant (2 x 360 MW) at Laibin B. This is the first Chinese BOOT contract in the power domain entirely financed by foreign capital. The two western companies which were retained for this project, following an international call for offers, invest USD 150 million of its own founds in this USD 600 million project. They will hold 60% and 40% of the capital of the company created for this project, respectively. The construction power plant is planned to be completed at the end of 1999 - beginning of 2000. After 15 years of industrial operation the power plant will be transferred to the autonomous government of the Province Guangxi. The communique contains the following 8 files: 1. The Laibin B power plant; 2. Build, Own, Operate, Transfer; 3. The autonomous Guangxi Province; 4. An outline of EDF in China; 5. Profile/activities of GEC ALSTHOM in China; 6. The 'Credit Agricole Indosuez' in China; 7. BZW Barclays PLC; 8. HSBC Investment Banking in China.

  18. 76 FR 82295 - Central Power & Lime LLC; Notice of Filing

    Science.gov (United States)

    2011-12-30

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Central Power & Lime LLC; Notice of Filing December 23, 2011. Take notice that on December 22, 2011, Central Power & Lime LLC, pursuant to sections 18 CFR 292.205(c) and...

  19. Solar power plant performance evaluation: simulation and experimental validation

    Science.gov (United States)

    Natsheh, E. M.; Albarbar, A.

    2012-05-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  20. A novel Beam-Down System for Solar Power Generation with Multi-Ring Central Reflectors and Molten Salt Thermal Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tamaura, Y.; Utamura, M.; Kaneko, H.; Hasuike, H.; Domingo, M.; Relloso, S.

    2006-07-01

    A new concept of beam-down solar power with thermal storage is proposed. The system is featured in an optical system with multi-ring central reflectors and a liquid film molten salt thermal receiver installed near ground level. Its feasibility study has been carried out and power generation cost as well as EPC cost has been estimated. To compensate the drawback to a beam-down solar concentrating system in optical losses, a new receiver concept of liquid film molten salt thermal receiver is designed to aim at higher thermal efficiency than that of tubular receiver. Molten salt liquid film is formed along the inner surface of the receiver wall. The liquid film flows down by gravity. It is shown that the liquid film receiver has a high heat exchange potential up to 2MW/m2 of solar beam flux on the inner wall surface and proved to be feasible. Assuming 24 hour continuous power generation located at Almeria Spain, conceptual designs for two capacities of 120MWt (commercial plant) and 20MWt (pilot plant) have been made. The height and the radius of the central receiver have been optimized as a result of trade off of optical loss and the cost of the central reflector and its support structure. The total cost of the Beam-Down will become 8.37 US cents/kWh, which will be competitive with coal and natural gas, when crude oil cost increases. TITECH (Tokyo Institute of Technology) plans to launch an international program to develop the innovative/cheaper solar tower beam--down concentrating system. (Author)

  1. Technical efficiency of thermoelectric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Carlos Pestana [Instituto de Economia e Gestao, Technical University of Lisbon, Rua Miguel Lupi, 20, 1249-078 Lisbon (Portugal); Peypoch, Nicolas [GEREM, LAMPS, IAE, Universite de Perpignan Via Domitia, 52 avenue Paul Alduy, F-66860 Perpignan (France)

    2008-11-15

    This paper analyses the technical efficiency of Portuguese thermoelectric power generating plants with a two-stage procedure. In the first stage, the plants' relative technical efficiency is estimated with DEA (data envelopment analysis) to establish which plants perform most efficiently. These plants could serve as peers to help improve performance of the least efficient plants. The paper ranks these plants according to their relative efficiency for the period 1996-2004. In a second stage, the Simar and Wilson [Simar, L., Wilson, P.W., 2007. Estimation and inference in two-stage, semi-parametric models of production processes. Journal of Econometrics 136, 1-34] bootstrapped procedure is adopted to estimate the efficiency drivers. Economic implications arising from the study are considered. (author)

  2. Efficiency improvement of thermal coal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hourfar, D. [VEBA Kraftwerke Ruhr Ag, Gelsenkirchen (Germany)

    1996-12-31

    The discussion concerning an increase of the natural greenhouse effect by anthropogenic changes in the composition of the atmosphere has increased over the past years. The greenhouse effect has become an issue of worldwide debate. Carbon dioxide is the most serious emission of the greenhouse gases. Fossil-fired power plants have in the recent past been responsible for almost 30 % of the total CO{sub 2} emissions in Germany. Against this background the paper will describe the present development of CO{sub 2} emissions from power stations and present actual and future opportunities for CO{sub 2} reduction. The significance attached to hard coal as one of today`s prime sources of energy with the largest reserves worldwide, and, consequently, its importance for use in power generation, is certain to increase in the years to come. The further development of conventional power plant technology, therefore, is vital, and must be carried out on the basis of proven operational experience. The main incentive behind the development work completed so far has been, and continues to be, the achievement of cost reductions and environmental benefits in the generation of electricity by increasing plant efficiency, and this means that, in both the short and the long term, power plants with improved conventional technology will be used for environmentally acceptable coal-fired power generation.

  3. Robotized Inspection of Vertical Structures of a Solar Power Plant Using NDT Techniques

    Directory of Open Access Journals (Sweden)

    Torsten Felsch

    2015-03-01

    Full Text Available Concentrated solar power (CSP plants are expansive facilities that require substantial inspection and maintenance. A fully automated inspection robot increases the efficiency of maintenance work, reduces operating and maintenance costs, and improves safety and work conditions for service technicians. This paper describes a climbing robot that is capable of performing inspection and maintenance on vertical surfaces of solar power plants, e.g., the tubes of the receiver in a central tower CSP plant. Specifically, the service robot’s climbing mechanism is explained and the results of the nondestructive inspection methods are reviewed. The robot moves on the panels of the receiver in the tower and aligns the sensors correctly for inspection. The vertical movement of the climbing kinematics is synchronized with the movement of the tower’s crane. Various devices that detect surface defects and thickness losses inside the tube were integrated into the robot. Since the tubes are exposed to very high radiation, they need to be inspected regularly.

  4. Methodology of aging management in structures, systems and components of a nuclear power plant and its application to a pilot program in Laguna Verde; Metodologia de la gestion del envejecimiento en estructuras, sistemas y componentes de una central nuclear y su aplicacion a un programa piloto en Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Jarvio C, G. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Fernandez S, G. [Comision Federal de Electricidad, Gerencia de Centrales Nucleoelectricas, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5, Dos Bocas, 54270 Veracruz (Mexico)], e-mail: gfdezs@cfe.gob.mx

    2009-10-15

    From its origin the nuclear power plants confront the effects of time and of environment, giving as result the aging of its structures, systems and components. In this document the general process is described for the establishment of Aging Management Program developed by IAEA. Following the program methodology is guaranteed that a nuclear power plant manages the aging effects appropriately and to make decisions for its solution, assuring the characteristic functions of structures, systems and components of same nuclear power plant. On the other hand, the implantation of an aging management program constitutes the base for development of a licence renovation program, like it can be the specific case of the Central Laguna Verde Units 1 and 2. (Author)

  5. POSSPOW: Possible Power of Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Giebel, Gregor; Göçmen, Tuhfe; Sørensen, Poul Ejnar

    2013-01-01

    Introduction In recent years, the very large offshore wind farms were designed as wind power plants, including possibilities to contribute to the stability of the grid by offering grid services (also called ancillary services). One of those services is reserve power, which is achieved by down......-regulating the wind farm from its maximum possible power. The power can be ramped up quite quickly, but the influence of wakes makes it difficult to assess the exact amount of down-regulation available to sell. Currently, Transmission System Operators (TSOs) have no real way to determine exactly the possible power...... will be verified on some of the large offshore wind farms owned by Vattenfall, and possibly in a DONG Energy wind farm too. Dedicated experiments to the wind flow in large offshore wind farms are planned. Main body of abstract Modern wind turbines have a SCADA signal called possible power. In normal operation...

  6. Techno-economic projections for advanced small solar thermal electric power plants to years 1990--2000

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, T.; Manvi, R.; Roschke, E.J.; El Gabalawi, N.; Herrera, G.; Kuo, T.J.; Chen, K.H.

    1978-11-15

    Advanced technologies applicable to solar thermal electric power systems in the 1990--2000 time-frame are delineated for power applications that fulfill a wide spectrum of small power needs with primary emphasis on power ratings <10 MWe. Techno-economic projections of power system characteristics (energy and capital costs as a function of capacity factor) are made based on development of identified promising technologies. The key characteristic of advanced technology systems is an efficient low-cost solar energy collection while achieving high temperatures for efficient energy conversion. Two-axis tracking systems such as the central receiver or power tower concept and distributed parabolic dish receivers possess this characteristic. For these two basic concepts, advanced technologies including, e.g., conversion systems such as Stirling engines, Brayton/Rankine combined cycles and storage/transport concepts encompassing liquid metals, and reversible-reaction chemical systems are considered. In addition to techno-economic aspects, technologies are also judged in terms of factors such as developmental risk, relative reliability, and probability of success. Improvements accruing to projected advanced technology systems are measured with respect to current (or pre-1985) steam-Rankine systems, as represented by the central receiver pilot plant being constructed near Barstow, California. These improvements, for both central receivers and parabolic dish systems, indicate that pursuit of advanced technology across a broad front can result in post-1985 solar thermal systems having the potential of approaching the goal of competitiveness with conventional power systems; i.e., capital costs of $600 kWe and energy costs of 50 mills/kWe-hr (1977 dollars).

  7. Capital cost: pressurized water reactor plant. Commercial electric power cost studies

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-01

    The investment cost study for the 1139 MW(e) pressurized water reactor (PWR) central station power plant consists of two volumes. This volume contains the drawings, equipment list and site description.

  8. Reliability of the Solar One plant during the power production phase: August 1, 1984--July 31, 1987

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, G.J.; Lopez, C.W.

    1988-10-01

    The power production phase at Solar One spanned three years from August 1, 1984 through July 31, 1987. In that period the plant achieved an average availability, during hours of sunshine, of 81.7%. This report presents the frequencies and causes of the plant outages that occurred. The eleven most important causes composed 75% of the total outage time. Qualitative insights related to the origin and mitigation of these causes are provided. Also presented are insights and statistics regarding the reliability of the heliostat field. The quantitative and qualitative information presented in this report will be useful to studies aimed at improving the reliability of future solar central receiver power plants. 20 refs., 11 figs., 3 tabs.

  9. Automation of hydroelectric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Grasser, H.S. (Consolidated Papers, Inc., Wisconsin Rapids, WI (US))

    1990-03-01

    This paper describes how the author's company has been automating its hydroelectric generating plants. The early automations were achieved with a relay-type supervisory control system, relay logic, dc tachometer, and a pneumatic gate-position controller. While this system allowed the units to be started and stopped from a remote location, they were operated at an output that was preset by the pneumatic control at the generating site. The supervisory control system at the site provided such information as unit status, generator breaker status, and a binary coded decimal (BCD) value of the pond level. The generating units are started by energizing an on-site relay that sets the pneumatic gate controller to a preset value above the synchronous speed of the hydroelectric generator. The pneumatic controller then opens the water-wheel wicket gates to the preset startup position. As the hydroelectric generator starts to turn, the machine-mounted dc tachometer produces a voltage. At a dc voltage equivalent to synchronous speed, the generator main breaker closes, and a contact from the main breaker starts a field-delay timer. Within a few seconds, the field breaker closes. Once the cycle is complete, a relay changes the pneumatic setpoint to a preset operating point of about 8/10 wicket gate opening.

  10. Optimization of a Virtual Power Plant to Provide Frequency Support.

    Energy Technology Data Exchange (ETDEWEB)

    Neely, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lave, Matthew Samuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Delhotal, Jarod James [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    Increasing the penetration of distributed renewable sources, including photovoltaic (PV) sources, poses technical challenges for grid management. The grid has been optimized over decades to rely upon large centralized power plants with well-established feedback controls, but now non-dispatchable, renewable sources are displacing these controllable generators. This one-year study was funded by the Department of Energy (DOE) SunShot program and is intended to better utilize those variable resources by providing electric utilities with the tools to implement frequency regulation and primary frequency reserves using aggregated renewable resources, known as a virtual power plant. The goal is to eventually enable the integration of 100s of Gigawatts into US power systems.

  11. Follow-up of the results of the nuclear power plant stress tests and action plan.; Seguimiento de los resultados de las pruebas de resistencia de las centrales nucleares y plan de accion

    Energy Technology Data Exchange (ETDEWEB)

    Mellado Jimenez, I.

    2012-07-01

    The results of the stress tests carried out by the European nuclear power plants in the wake of the Fukushima Daiichi accident, subsequently subjected to peer reviews, have made it possible to identify the measures to be applied to improve safety. Action plans have been put in place to implement these measures within appropriate time frames. (Author)

  12. The National Institute of Nuclear Research (ININ) and its participation in the External Radiological Emergency Plans at Laguna Verde Power plant; El ININ y su participacion en el Plan de Emergencia Radiologica Externo de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, G. [Instituto Nacional de Investigaciones Nucleares, Departamento de Proteccion Radiologica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1998-07-01

    In this article it is described the form in which the ININ participates in the External Radiological Emergency Plan at Laguna Verde Power plant. It is set the objective, mission and organization of this plan. The responsibilities and activities that plan has assigned are mentioned also the organization to fulfil them and the obtained results during 9 years of participation. (Author)

  13. UPVAPOR: computer application for the analysis of the results of Cofrentes Nuclear Power Plant production; UPVAPOR: Aplicacion informatica para el analisis de resultados de produccion en Central Nuclear Cofrentes

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M. J.; Baraza Peregrin, A.; Bucho Piqueras, L.; Vaquer Perez, J. I.; Lopez Lopez, B.

    2010-07-01

    UPVapor is a software developed for the Cofrentes Nuclear Power Plant Group of Results. This application presents a graphical environment for analysis in which the user has available many variables registered to configure the graphics. This application saves a lot of time at work because it allows other users to do their own analysis without resorting to analysts.

  14. Virtual environments for nuclear power plant design

    Energy Technology Data Exchange (ETDEWEB)

    Brown-VanHoozer, S.A.; Singleterry, R.C. Jr.; King, R.W. [and others

    1996-03-01

    In the design and operation of nuclear power plants, the visualization process inherent in virtual environments (VE) allows for abstract design concepts to be made concrete and simulated without using a physical mock-up. This helps reduce the time and effort required to design and understand the system, thus providing the design team with a less complicated arrangement. Also, the outcome of human interactions with the components and system can be minimized through various testing of scenarios in real-time without the threat of injury to the user or damage to the equipment. If implemented, this will lead to a minimal total design and construction effort for nuclear power plants (NPP).

  15. Materials availability for fusion power plant construction

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, J.N.; Erickson, L.E.; Engel, R.L.; Foley, T.J.

    1976-09-01

    A preliminary assessment was made of the estimated total U.S. material usage with and without fusion power plants as well as the U.S. and foreign reserves and resources, and U.S. production capacity. The potential environmental impacts of fusion power plant material procurement were also reviewed including land alteration and resultant chemical releases. To provide a general measure for the impact of material procurement for fusion reactors, land requirements were estimated for mining and disposing of waste from mining.

  16. Advanced coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hebel, G.; Weirich, P.H.

    1988-02-01

    Reconstruction of coal-fired power plants under the aspects of higher economic efficiency and lower emissions has become more interesting as the petroleum and natural gas reserves have become shorter. A number of advanced concepts have been presented in the last few years and tested in experimental facilities, pilot plants and demonstration plants. If construction is envisaged within the next five years, better steam processes and coal gas turbines should be employed. Supercharged steam generators, which will bring about further improvements, will be available by the mid-Nineties.

  17. Guinea_WADC00321_ADBG_Guinea_Power_Plants

    Data.gov (United States)

    United Nations Cartographic Section — Data for power plants with total installed generating capacity > 10 mw from the Platts World Electric Power Plants Database (WEPP 2006). Plants were georeferenced...

  18. Occupational exposure at a contemplated Belarussian power plant fired with contaminated biomass

    DEFF Research Database (Denmark)

    Andersson, Kasper Grann; Fogh, C.L.; Roed, Jørn

    1999-01-01

    To meet the current demand in Belarus for remediation of the vast forest areas that were contaminated by the Chernobyl accident and at the same time establish a much needed energy production, applying contaminated forest biomass as fuel in special power plants is being considered. This paper...... focuses on the radiation doses that may be received by workers at such a power plant. By Monte Carlo modelling based on a Danish biofuel power plant design it was found that the highest dose rates within the power plant would be those to people standing near the fly ash silo, bottom ash containers and so...

  19. Evaluation of line focus solar central power systems. Volume II. Systems evaluation

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

  20. Conceptual design of an advanced water/steam central solar receiver, volume 1

    Science.gov (United States)

    Matthews, F. T.; Payne, H. M.; Jones, B. O.; Snyder, T. K.; Davidson, M. J.

    1980-06-01

    A drum type boiler with forced circulation evaporator using rifled tubing can be designed for the high heat flux of a North field collector without the problems associated with departure of nuclear boiling. Existing boiler technology and materials can be used to design an advanced water/steam receiver. Rifled tubing was shown by test data to provide protection to evaporator panels at peak heat flux levels 30 percent greater than the design point of these receivers. Estimated budgetary type costs of these receivers vary from $10 per pound of steam for the large receiver to $13 per pound of steam for the smaller units. Fatigue life was conservatively calculated to be 30,000 full strain range cycles. This is adequate for the diurnal cycling, plus some cloud over a 30 year period. It is possible that the allowable creep fatigue cycles may be increased to 40,000 - 50,000 by an inelastic stress analysis. This analysis was recommended for future work and is required to resolve the cyclic lifetime of these receivers. Additional analysis is also needed to resolve receiver and plant control systems.

  1. Electrochemical Power Plant for Terrestrial Flight Platforms Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An electrochemical power plant is proposed by MicroCell Technologies to provide power to terrestrial flight platforms. Our power plant is based upon a proton...

  2. 77 FR 47121 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Units 1 and 2...

    Science.gov (United States)

    2012-08-07

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Exemption 1.0 Background Calvert Cliffs Nuclear Power Plant, LLC (the licensee) is the holder of Renewed..., ``Fatigue Management for Nuclear Power Plant Personnel,'' endorses the Nuclear Energy......

  3. 75 FR 66802 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2010-10-29

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2... Regulatory Commission (the Commission) has granted the request of Calvert Cliffs Nuclear Power Plant, LLC... Operating License Nos. DPR-53 and DPR-69 for the Calvert Cliffs Nuclear Power Plant, Unit......

  4. 76 FR 39908 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-07-07

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2.... DPR-53 and DPR-69, for the Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 (CCNPP), respectively... (ISFSI), currently held by Calvert Cliffs Nuclear Power Plant, LLC as owner and licensed......

  5. Results of molten salt panel and component experiments for solar central receivers: Cold fill, freeze/thaw, thermal cycling and shock, and instrumentation tests

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, J.E.; Ralph, M.E.; Chavez, J.M.; Dunkin, S.R.; Rush, E.E.; Ghanbari, C.M.; Matthews, M.W.

    1995-01-01

    Experiments have been conducted with a molten salt loop at Sandia National Laboratories in Albuquerque, NM to resolve issues associated with the operation of the 10MW{sub e} Solar Two Central Receiver Power Plant located near Barstow, CA. The salt loop contained two receiver panels, components such as flanges and a check valve, vortex shedding and ultrasonic flow meters, and an impedance pressure transducer. Tests were conducted on procedures for filling and thawing a panel, and assessing components and instrumentation in a molten salt environment. Four categories of experiments were conducted: (1) cold filling procedures, (2) freeze/thaw procedures, (3) component tests, and (4) instrumentation tests. Cold-panel and -piping fill experiments are described, in which the panels and piping were preheated to temperatures below the salt freezing point prior to initiating flow, to determine the feasibility of cold filling the receiver and piping. The transient thermal response was measured, and heat transfer coefficients and transient stresses were calculated from the data. Freeze/thaw experiments were conducted with the panels, in which the salt was intentionally allowed to freeze in the receiver tubes, then thawed with heliostat beams. Slow thermal cycling tests were conducted to measure both how well various designs of flanges (e.g., tapered flanges or clamp type flanges) hold a seal under thermal conditions typical of nightly shut down, and the practicality of using these flanges on high maintenance components. In addition, the flanges were thermally shocked to simulate cold starting the system. Instrumentation such as vortex shedding and ultrasonic flow meters were tested alongside each other, and compared with flow measurements from calibration tanks in the flow loop.

  6. Safety and Radiation Protection at Swedish Nuclear Power Plants 2005

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-15

    other things. Up-to-date and documented safety analyses must be prepared and actively be included in both the preventive safety work and in connection with plant modifications. The licensees have implemented design analysis projects for a long period of time and clarified and stringent regulations for safety analyses have entered into force in 2005. As a result, updated safety reports exist for many of the facilities and schedules exist for the supplementary work that remains to be done. SKI's reinforced supervision of Barsebaeck 2 continued until the closure of the reactor on May 31, 2005. In SKI's opinion, BKAB mainly handled the lengthy facility closure in a satisfactory manner. The handling of nuclear waste at the nuclear facilities has mainly functioned well. The same applies to the operation of the Repository for Low and Intermediate-level Operational Waste (SFR-1) and the Central Interim Storage Facility for Spent Nuclear Fuel (CLAB). The overall evaluation of the Swedish Radiation Protection Authority (SSI) is that radiation protection at Swedish nuclear power plants has functioned well in 2005. The total radiation dose to the personnel at Swedish nuclear power plants was 9.2 manSv, which agrees with the average value of the total radiation doses over the last five years (9 manSv). No-one received a radiation dose in excess of the established dose limits and the radiation levels in the facilities are largely unchanged compared with previous years. The radiation doses to the public from the Swedish nuclear power plants continue to be low. SSI considers that continuous work is also needed in the future at the facilities to further reduce radioactive releases by applying the best available technique (BAT) and other measures. The control measurements that SSI is conducting on environmental samples from around the nuclear power facilities as well as on radioactive releases to water show a good agreement with the licensees' own measurements.

  7. Turbomachinery for small solar power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bammert, K.; Heikal, H.; Mobarak, A.

    1981-01-01

    Conversion of solar energy into mechanical or electrical energy in small solar power plants (10 bis 500 kW) requires new design criteria, especially with regard to turbomachinery. The cycles suitable for solar power production are affected by many variables such as kinds of working fluid, range of power and maximum cycle temperature determined by the type of collector. Also, the size of the plant will influence the selection of the various components of the plant, especially that of the turbomachinery. A study of a suitable thermodynamic cycle and working fluid is done for different ranges of power and temperature. The working fluids considered are steam, toluene, and refrigerant 113 for the Rankine cycle systems and air for gas turbine systems. For Rankine cycles, turbine selection is a problem in the small power range. This is mainly due to the fact, that for high efficiency the enthalpy drop should be as high as possible, and the mass flow rate of the working fluid through the turbine becomes very small. This, in turn, requires high rotational speed, multistaging and partial admission, especially if water is the working fluid. Toluene offers better design criteria for the turbine in the same temperature and power range (50-200 kW). For the very small range (10 kW) refrigerant 113 or similar should be used, otherwise severe design problems with the turbine will occur. In this power range, photovoltaics may also be considered. For high concentration systems with Brayton cycles (800-1000/sup 0/C) only open-cycle gas turbine plants should be used.

  8. Elk and plants thrive near power lines

    Energy Technology Data Exchange (ETDEWEB)

    Lustre, L.

    1997-11-01

    Butterflies and elk gather in clearings near power line right-of-ways and on the edges of such clearings, where the wild flowers and plants that have widely disappeared as a result of intensive farming and subsurface drainage of fields have found a good habitat. Ornamental coniferous trees, various herbs and assorted berries do well and can be harvested near power lines from woodland clearings once thought unfit for cultivation. IVS, the nationwide network company, takes part in many projects aiming both to increase productive utilization of land areas under power lines and to promote biodiversity

  9. Geothermal Cogeneration: Iceland's Nesjavellir Power Plant

    Science.gov (United States)

    Rosen, Edward M.

    2008-01-01

    Energy use in Iceland (population 283,000) is higher per capita than in any other country in the world. Some 53.2% of the energy is geothermal, which supplies electricity as well as heated water to swimming pools, fish farms, snow melting, greenhouses, and space heating. The Nesjavellir Power Plant is a major geothermal facility, supplying both…

  10. Report on Hawaii Geothermal Power Plant Project

    Energy Technology Data Exchange (ETDEWEB)

    1983-06-01

    The report describes the design, construction, and operation of the Hawaii Geothermal Generator Project. This power plant, located in the Puna District on the island of Hawaii, produces three megawatts of electricity from the steam phase of a geothermal well. (ACR)

  11. A Market-Based Virtual Power Plant

    DEFF Research Database (Denmark)

    You, Shi; Træholt, Chresten; Poulsen, Bjarne

    2009-01-01

    The fast growing penetration of Distributed Energy Resources (DER) and the continuing trend towards a more liberalized electricity market requires more efficient energy management strategies to handle both emerging technical and economic issues. In this paper, a market-based Virtual Power Plant...

  12. Design and evaluation of ship's power plants

    NARCIS (Netherlands)

    Meijer, G.J.; Nienhuis, U.; Vugt, J. van; Folkersma, W.

    1999-01-01

    The cruise industry is host to major changes in the way the skip's power plants are configured. Diesel-electric propulsion has replaced most diesel-mechanic systems for larger ships. Podded propulsion is making serious headway and gas turbines are currently under order. In future, fuel cells, perman

  13. Direct FuelCell/Turbine Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2008-09-30

    This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply

  14. Heber geothermal demonstration power plant. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    The binary power plant is to be a 45 MW net electrical facility deriving energy from the low salinity (14,000 ppM), moderate temperature (360/sup 0/F, 182/sup 0/C) Heber reservoir in Southern California. The optimized baseline design established for the power plant is described, and the design and optimization work that formed the basis for the baseline design is documented. The work accomplished during Phase II, Preliminary Design is also recorded, and a base provided from which detailed plant design could be continued. Related project activities in the areas of licensing, environmental, cost, and schedule are also described. The approach used to establish the Phase II optimized baseline design was to (1) review the EPRI Phase I conceptual design and feasibility studies; (2) identify current design criteria and state-of-the-art technology; and (3) develop a preliminary design optimized to the Heber site based on utiliity standards.

  15. Recent Advances in Ocean Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Kang-Heon Lee

    2015-10-01

    Full Text Available In this paper, recent advances in Ocean Nuclear Power Plants (ONPPs are reviewed, including their general arrangement, design parameters, and safety features. The development of ONPP concepts have continued due to initiatives taking place in France, Russia, South Korea, and the United States. Russia’s first floating nuclear power stations utilizing the PWR technology (KLT-40S and the spar-type offshore floating nuclear power plant designed by a research group in United States are considered herein. The APR1400 and SMART mounted Gravity Based Structure (GBS-type ONPPs proposed by a research group in South Korea are also considered. In addition, a submerged-type ONPP designed by DCNS of France is taken into account. Last, issues and challenges related to ONPPs are discussed and summarized.

  16. Global thermal pollution of rivers from thermoelectric power plants

    Science.gov (United States)

    Raptis, C. E.; van Vliet, M. T. H.; Pfister, S.

    2016-10-01

    Worldwide riverine thermal pollution patterns were investigated by combining mean annual heat rejection rates from power plants with once-through cooling systems with the global hydrological-water temperature model variable infiltration capacity (VIC)-RBM. The model simulates both streamflow and water temperature on 0.5° × 0.5° spatial resolution worldwide and by capturing their effect, identifies multiple thermal pollution hotspots. The Mississippi receives the highest total amount of heat emissions (62% and 28% of which come from coal-fuelled and nuclear power plants, respectively) and presents the highest number of instances where the commonly set 3 °C temperature increase limit is equalled or exceeded. The Rhine receives 20% of the thermal emissions compared to the Mississippi (predominantly due to nuclear power plants), but is the thermally most polluted basin in relation to the total flow per watershed, with one third of its total flow experiencing a temperature increase ≥5 °C on average over the year. In other smaller basins in Europe, such as the Weser and the Po, the share of the total streamflow with a temperature increase ≥3 °C goes up to 49% and 81%, respectively, during July-September. As the first global analysis of its kind, this work points towards areas of high riverine thermal pollution, where temporally finer thermal emission data could be coupled with a spatially finer model to better investigate water temperature increase and its effect on aquatic ecosystems.

  17. Statistical modeling and analysis of the influence of antenna polarization error on received power

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The problem of statistical modeling of antenna polarization error is studied and the statistical characteristics of antenna's received power are analyzed. A novel Stokes-vector-based method is presented to describe the conception of antenna's polarization purity. Statistical model of antenna's polarization error in polarization domain is then built up. When an antenna with polarization error of uniform distribution is illuminated by an arbitrary polarized incident field, the probability density of antenna's received power is derived analytically. Finally, a group of curves of deviation and standard deviation of received power are plotted numerically.

  18. Model-Based Power Plant Master Control

    Energy Technology Data Exchange (ETDEWEB)

    Boman, Katarina; Thomas, Jean; Funkquist, Jonas

    2010-08-15

    The main goal of the project has been to evaluate the potential of a coordinated master control for a solid fuel power plant in terms of tracking capability, stability and robustness. The control strategy has been model-based predictive control (MPC) and the plant used in the case study has been the Vattenfall power plant Idbaecken in Nykoeping. A dynamic plant model based on nonlinear physical models was used to imitate the true plant in MATLAB/SIMULINK simulations. The basis for this model was already developed in previous Vattenfall internal projects, along with a simulation model of the existing control implementation with traditional PID controllers. The existing PID control is used as a reference performance, and it has been thoroughly studied and tuned in these previous Vattenfall internal projects. A turbine model was developed with characteristics based on the results of steady-state simulations of the plant using the software EBSILON. Using the derived model as a representative for the actual process, an MPC control strategy was developed using linearization and gain-scheduling. The control signal constraints (rate of change) and constraints on outputs were implemented to comply with plant constraints. After tuning the MPC control parameters, a number of simulation scenarios were performed to compare the MPC strategy with the existing PID control structure. The simulation scenarios also included cases highlighting the robustness properties of the MPC strategy. From the study, the main conclusions are: - The proposed Master MPC controller shows excellent set-point tracking performance even though the plant has strong interactions and non-linearity, and the controls and their rate of change are bounded. - The proposed Master MPC controller is robust, stable in the presence of disturbances and parameter variations. Even though the current study only considered a very small number of the possible disturbances and modelling errors, the considered cases are

  19. 10-MWe pilot-plant-receiver panel test requirements document solar thermal test facility

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-25

    Testing plans for a full-scale test receiver panel and supporting hardware which essentially duplicate both physically and functionally, the design planned for the Barstow Solar Pilot Plant are presented. Testing is to include operation during normal start and shutdown, intermittent cloud conditions, and emergencies to determine the panel's transient and steady state operating characteristics and performance under conditions equal to or exceeding those expected in the pilot plant. The effects of variations of input and output conditions on receiver operation are also to be investigated. Test hardware are described, including the pilot plant receiver, the test receiver assembly, receiver panel, flow control, electrical control and instrumentation, and structural assembly. Requirements for the Solar Thermal Test Facility for the tests are given. The safety of the system is briefly discussed, and procedures are described for assembly, installation, checkout, normal and abnormal operations, maintenance, removal and disposition. Also briefly discussed are quality assurance, contract responsibilities, and test documentation. (LEW)

  20. The safety analysis and thermohydraulic methodologies for the power updating analyses in Spanish PWR plants; Methodologias de diseno termohidraulico y de analisis de seguridad en los aumentos de potencia de centrales PWR

    Energy Technology Data Exchange (ETDEWEB)

    Salesa, F.

    2014-02-01

    This article describes the Safety Analysis and Thermohydraulic methodologies used by ENUSA for the Power Updating analyses in Spanish PWR plants of Westinghouse design: Design tools have been developed over the first cycles resulting new correlations of DNB, fitted to the new fuel assemblies, new DNBR calculation methodology and other improvements in the design areas. Using these methodologies, the available margins between design and limit values are wider. These new margins have allowed to accomplish the design criteria under the new power updating operational conditions. (Author)

  1. Influence of communication systems to support the services in nuclear power plants; Influencia de los sistemas de comunicaciones en el apoyo a los servicios prestados a las centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Moron, P.; Ruiz, J. C.; Guerra, F. J.

    2005-07-01

    The continuous technological advances related to communications infrastructures and mobility solutions, increasingly within reach of the companies, are leading to upgrade most of the associated processes within a service company. Tecnatom is not irrelevant to it and is carrying out a technological development for the intercommunication between its facilities, and the spanish nuclear power plants. Consequently is carrying out and adjustment and optimization of their services. All the performances are included in a corporate project to three years named ARCOM. Along 2004 the first results have been obtained, remote analysis of data has been made and the access to the management information systems from the nuclear power stations has been facilitated. (Author)

  2. Configuration management in nuclear power plants

    CERN Document Server

    2003-01-01

    Configuration management (CM) is the process of identifying and documenting the characteristics of a facility's structures, systems and components of a facility, and of ensuring that changes to these characteristics are properly developed, assessed, approved, issued, implemented, verified, recorded and incorporated into the facility documentation. The need for a CM system is a result of the long term operation of any nuclear power plant. The main challenges are caused particularly by ageing plant technology, plant modifications, the application of new safety and operational requirements, and in general by human factors arising from migration of plant personnel and possible human failures. The IAEA Incident Reporting System (IRS) shows that on average 25% of recorded events could be caused by configuration errors or deficiencies. CM processes correctly applied ensure that the construction, operation, maintenance and testing of a physical facility are in accordance with design requirements as expressed in the d...

  3. Rol del fallo mecánico en la optimización del mantenimiento en una central nuclear//Role of the mechanical failure during the maintenance optimization in the nuclear power plant

    Directory of Open Access Journals (Sweden)

    Antonio Torres-Valle

    2012-05-01

    Full Text Available Entre las más recientes aplicaciones del Análisis Probabilista de Seguridad (1997 – 2003 de la Central Nuclear Embalse en Argentina, está el Programa de Mantenimiento Orientado a la Seguridad (2006– 2009 el cual se ha desarrollado con el empleo de la metodología de Mantenimiento Centrado en la Confiabilidad (RCM en inglés. El objetivo general del artículo es demostrar la alta contribución de los fallos mecánicos en el diseño de las políticas de mantenimiento de varios sistemas de la instalación a través del empleo de la metodología RCM. La composición, estructura y políticas de explotación de los sistemas tecnológicos de muchas instalaciones con riesgo asociado, similares a las de los sistemas analizados en este estudio, permite inferir que los resultados que se obtendrán serán equivalentes de aplicarse la metodología RCM en dichas instalaciones. Palabras claves: mantenimiento centrado en la confiabilidad, mantenimiento predictivo, mantenimiento preventivo, fallo mecánico, seguridad, confiabilidad, riesgo.______________________________________________________________________________ Abstract One of the most recent applications of Probabilistic Safety Analysis (1997 – 2003 to Embalse Nuclear Power Plant in Argentina, is the Safety Oriented Maintenance Program (2006 – 2009 developed with employment of the Reliability Centered Maintenance (RCM methodology. The general objective of the paper is to demonstrate the high contribution of the mechanical failures in the maintenance program design through the RCM methodology. The composition, structure and operation strategies of the technological systems of many risk associated facilities, similar to the analysed systems included in this study, allow deduce that the results will equivalent in case of application of RCM methodology in such facilities. Key words: reliability centered maintenance (RCM, predictive maintenance, preventive maintenance, mechanical failure, safety

  4. The Nuclear Safety Council's Instruction IS-30 on program requirements of fire protection at nuclear power plants; La instruccion IS-30 del consejo de Seguridad Nuclear sobre requisitos del programa de proteccion contraincendios en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Peco, J.

    2015-07-01

    The Nuclear Safety Councils Instrumentation IS-30 is the standard that establishes the fire protection program requirements for the Spanish nuclear power plants with operating license in order to satisfy the two fire protection objectives, which are the adoption of the defense-in-depth principle for fire protection and, by fire area confinement, to ensure that one train of components needed to achieve and maintain the safe shutdown conditions is free of fire damage, and that radioactive liberation is minimized. (Author)

  5. Quality Assurance in the Vandellos 1 Nuclear Power Plant Dismantling and Decommissioning Project; La garantia de calidad en el proyecto de desmantelamiento y clausura de la Central Nuclear de Vandellos I

    Energy Technology Data Exchange (ETDEWEB)

    Soto Lanuza, A.

    2000-07-01

    General description of the Quality Assurance System established and implemented for the efficient development of the current activities specified in the Dismantling and Decommissioning Plan for Vandellos I Nuclear Power Plant. Aspects related to the Quality organization, scope and applicability on the established Quality Assurance Manual, availability of requirements and recommendations on quality as well as actions to be taken for the correct verification on the quality and practical application of the Manual should be described. (Author)

  6. CAGE: A standard design application to nuclear power plants of Cofrentes, Almaraz and Trillo; CAGE: Un diseno estandar de aplicacion a las centrales nucleares de Cofrentes, Almaraz y Trillo

    Energy Technology Data Exchange (ETDEWEB)

    Cubian Martinez, B.; Gomez Gomez, M.; Zornoza Garcia-Andrade, J.; Turrion Lopez, F.; Barrio, M. A. del; Cobos Perabad, A.; Garcia-Serrano, J. L.

    2016-08-01

    Design, engineering, supply, construction, assembly, supervision and quality control, construction management and commissioning of Alternative Emergency Management Centres (CAGES) of nuclear power plants Cofrentes (CNC), Almaraz (CNA) and Trillo (CNT) were awarded in the first half of 2014 to Iberdrola Engineering and Construction (IIC). After obtaining the required building permits issued by municipalities, following the delivery of the corresponding, basic project and execution, in January 2015, began civil works at CNA, CNT and in February of this year in CNC. (Author)

  7. Ground failure in direct current systems of the Itaipu Hydroelectric Power Plant, Parana, Brazil. Impact in the operation; Falla a tierra en sistemas de corriente continua en la Central Hidroelectrica Itaipu, PR, Brasil. Impacto en la operacion

    Energy Technology Data Exchange (ETDEWEB)

    Soto Santacruz, Heriberto [Itaipu Binacional, Foz do Iguacu, PR (Brazil)]. E-mail: soto@itaipu.gov.py

    1998-07-01

    The objective of this work is to share with other companies the operation experience obtained by researching the direct current systems ground failure, in the Itaipu Hydroelectric Power Plant. During the research process electrical and/or electronic components can be damaged, and also human failures can occurred during the circuit connection and disconnection manoeuvres, necessary for the identification of the components causing the failures.

  8. New technologies of information treatment in the ERP of the Almaraz and Trillo nuclear power plants; Nuevas tecnologias de tratamiento de la informacion en el ERP de las centrales nucleares de Almaraz y Trillo

    Energy Technology Data Exchange (ETDEWEB)

    Martin Lopez-Suevos, C.; Gonzalez Crego, E.

    2013-03-01

    The Almaraz and Trillo Nuclear Power Plants are equipped with an Integrated Operation Management System (SIGE), which covers practically all of their transactional and management needs in all areas, with the exception of some specific engineering and simulation tools. In recent years, applications based on new computer technologies have been developed and integrated into the SIGE, including a Maintenance Dashboard, an Admissions Office ant the use of bar code readers, all of which are described in this article. (Author)

  9. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan; K. Coleman; R.W. Swindeman; J. Sarver; J. Blough; W. Mohn; M. Borden; S. Goodstine; I. Perrin

    2003-10-20

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), 35 MPa (5000 psi) steam. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop of advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced materials that will make it possible to maintain a cost-competitive, environmentally acceptable coal-based electric generation option. High sulfur coals will specifically benefit in this respect by having these advanced materials evaluated in high-sulfur coal firing conditions and from the significant reductions in waste generation inherent in the increased operational efficiency. Second, from a national prospective, the results of this program will enable domestic boiler manufacturers to successfully compete in world markets for building high-efficiency coal-fired power plants.

  10. ORC-mall scale power plant

    Energy Technology Data Exchange (ETDEWEB)

    Jokinen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Electromechanics

    1998-12-31

    In the conversion of low temperature heat into electricity, the greatest efficiency is obtained by using a Rankine cycle. The Organic Rankine cycle (ORC) is a Rankine cycle where an organic fluid is used instead of water as the working fluid. In the conventional ORC-solution, an axial turbine drives a standard generator through a high-speed gearbox. The system includes a separate feed pump, vacuum pump, lubrication system and requires several saft seals. The seals of the turbine have a limited working life in particular due to the high speed required. Thus, the entire present conventional ORC-plant is rather complicated and requires maintenance. To avoid these problems, a project was initiated at the Lappeenranta University of Technology to develop a high-speed, process fluid lubricated turbogenerator-feed pump as the prime mover of the ORC. The project has been continued in co-operation with the Helsinki University of Technology under the NEMO 2 program, the main goal being to build a demonstration power plant and to commercialise the project. The goals of the project were: (1) to model the ORC process, turbogenerator, and inverter, (2) to simulate the power plant in different normal and abnormal states, (3) to assess the advantages and disadvantages of various control systems, (4) to study network disturbances such as voltage and current harmonics and to research ways of reducing these disturbances, (5) to optimise heat exchanging surfaces and process parameters, and (6) to participate in the design of the demonstration power plant

  11. Externalities assessment of a coal power plant in the forest ecosystems in Valdecaballeros Area; Estimacion de las externalidades de una central termica de carbon en los ecosistemas forestales del Area de Valdecaballeros

    Energy Technology Data Exchange (ETDEWEB)

    Laforga, P.; Planas, B.

    1995-07-01

    The book is divided in two parts. The first one analyzes the critical load and level concepts, and the methodological framework for Environmental Impact Statement (E.L.S.). In line with this, critical loads and levels represent the system vulnerability and excedances of critical values identify zones where impacts could occur. These are evaluated according to a set of criteria, talking into account present and future land use, their socio cultural interest, economic value of their natural resources and ecological quality of the whole system. In addition to Environment Impact Statement of air pollutants, the proposed formalism allows assessing the external cost of gaseous emission. The second part applies the developed ideas to a practical case: a hypothetical coal power plant on Valdecaballeros (Badajoz, Spain). Environmental impact on forestry ecosystems is studied on a 70 km radius area around the plant. The assessment of the external costs rely on yield losses associated with gaseous emission of the hypothetical plant. (Author) 100 refs.

  12. Analysis of a natural draught tower in the circulation seawater system of nuclear power plant of Laguna Verde; Analisis de una torre de tiro natural en el sistema de agua de circulacion de mar de la central nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Vargas A, A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5, Veracruz (Mexico)], e-mail: francisco.tijerina@cfe.gob.mx

    2009-10-15

    The analysis of a natural draught tower in open circuit for the cooling system of seawater circulation on the nuclear power plant of Laguna Verde, it is based on conditions of 2027 MWt and 2317 MWt, where the flows of circulation water system hardly vary and whose purpose will be, to cool the seawater circulation. The circulation water system is used as heat drain in main condenser of turbo generator to condense the nuclear vapor. The annual average temperature in the seawater at present is of 26 C to the entrance to circulation water system and it is vary in accordance with the time of year. The mean temperature of leaving of circulation water system to the sea is of 41 C. Having a cooling tower to reduce the entrance temperature to the circulation water system, it improves the efficiency of thermal transfer in condenser, it improves the vacuum in condenser giving more operative margin to avoid condenser losses by air entrances and nuclear power plant shutdowns, as well as for to improve the efficiency of operative balance of nuclear power plant, also it prevents the impact in thermal transfer efficiency in condenser by the climatic change. (Author)

  13. The small-scale hydroelectric power plant project 'Les Esserts' in Boudry, Switzerland - Feasibility study and preliminary planning; Centrale des Esserts a Boudry. Etude de faisabilite et avant-projet detaille

    Energy Technology Data Exchange (ETDEWEB)

    Roelli, P.; Croci, S.; Ernst, J.-R.

    2004-07-01

    This report describes in details the project of the installation of a small-scale hydroelectric power plant on the river Areuse in Switzerland. Located on a 4 m high waterfall the plant includes a 10-13 m{sup 3}/s Kaplan turbine, which should deliver roughly 1.6 GWh/year for an installed power of about 500 kVA. The authors insist on the ecological aspect of the project. The plant will be built underground; the river track will be practically unchanged and the existing fish ladder maintained. The report includes maps and pictures of the site as well as technical drawings of the installation. An economic analysis of the project is presented and its viability is discussed. Finally, the authors state that the energy produced by this plant will certainly be certified under one of the Swiss labels 'naturemade star' or 'naturemade basic', in the framework of the federal government's promotion of renewable energy sources.

  14. Market integration of Virtual Power Plants

    DEFF Research Database (Denmark)

    Petersen, Mette Kirschmeyer; Hansen, Lars Henrik; Bendtsen, Jan Dimon;

    2013-01-01

    We consider a direct control Virtual Power Plant, which is given the task of maximizing the profit of a portfolio of flexible consumers by trading flexibility in Energy Markets. Spot price optimization has been quite intensively researched in Smart Grid literature lately. In this work, however, w...... are penetrated, the size of the profit is strongly dependent on the type of flexibility considered. We also find that penetrating several markets makes profits surprisingly robust to spot price prediction errors.......We consider a direct control Virtual Power Plant, which is given the task of maximizing the profit of a portfolio of flexible consumers by trading flexibility in Energy Markets. Spot price optimization has been quite intensively researched in Smart Grid literature lately. In this work, however, we...... develop a three stage market model, which includes Day-Ahead (Spot), Intra-Day and Regulating Power Markets. This allows us to test the hypothesis that the Virtual Power Plant can generate additional profit by trading across several markets. We find that even though profits do increase as more markets...

  15. Small-scale hydro power plant on the main drinking water line La Rippaz in Bex, Switzerland - Feasibility study; Petite centrale hydraulique. Aduction d'eau potable La Rippaz. Etude de faisabilite

    Energy Technology Data Exchange (ETDEWEB)

    Chapallaz, J.-M. [Jean-Marc Chapallaz, Ingenieur EPFL/SIA, Baulmes (Switzerland); Meylan, D. [Perret-Gentil et Rey et Associes SA, Ingenieurs civils et Ingenieurs Conseil EPF/SIA, Lausanne (Switzerland)

    2008-04-15

    This report for the Swiss Federal Office of Energy (SFOE) is a feasibility study for the replacement work of the drinking-water supply line from the location of the spring water collection to a water reservoir belonging to the rock-salt mining company 'Hotel des Salines' in Bex, Switzerland. Built 1887 and following years this water supply system has already been designed for power generation as well. However, a 40 kW micro-scale turbine has only been installed 2005 in the lower part of the water supply system (hydraulic head: 115 m). The new project includes the replacement of the existing piping by a penstock, the construction of a new water collection reservoir at the highest point, the construction of a new 300 kW hydro power plant using the upper part of the water supply system (hydraulic head: 520 m), and some improvements of the existing lower power plant. The available water flow rate lies in the range 57-70 l/s, all the year round. The question arising is whether this construction project could be financed by the benefit from the sale of electricity that could be produced by the two power plants. The authors of the study estimate the power production to be 2.5 kWh/y. If the electricity can be sold at least at CHF 0.20/kWh for 25 years this could finance the whole project that has an estimated cost of CHF 7,000,000.

  16. Safety in nuclear power plants in India

    Directory of Open Access Journals (Sweden)

    Deolalikar R

    2008-01-01

    Full Text Available Safety in nuclear power plants (NPPs in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operating and maintenance procedures, a well-defined waste management methodology, proper well documented and periodically rehearsed emergency preparedness and disaster management plans. The NPPs have occupational health policies covering periodic medical examinations, dosimetry and bioassay and are backed-up by fully equipped Personnel Decontamination Centers manned by doctors qualified in Occupational and Industrial Health. All the operating plants are ISO 14001 and IS 18001 certified plants. The Nuclear Power Corporation of India Limited today has 17 operating plants and five plants under construction, and our scientists and engineers are fully geared to take up many more in order to meet the national requirements.

  17. Safety in nuclear power plants in India.

    Science.gov (United States)

    Deolalikar, R

    2008-12-01

    Safety in nuclear power plants (NPPs) in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operating and maintenance procedures, a well-defined waste management methodology, proper well documented and periodically rehearsed emergency preparedness and disaster management plans. The NPPs have occupational health policies covering periodic medical examinations, dosimetry and bioassay and are backed-up by fully equipped Personnel Decontamination Centers manned by doctors qualified in Occupational and Industrial Health. All the operating plants are ISO 14001 and IS 18001 certified plants. The Nuclear Power Corporation of India Limited today has 17 operating plants and five plants under construction, and our scientists and engineers are fully geared to take up many more in order to meet the national requirements.

  18. Operational monitoring in German nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Seibold, A. [Technischer Ueberwachungs-Verein Suedwest e.V., Filderstadt (Germany); Bartonicek, J. [GKN Neckarwestheim, Im Steinbruch, Neckarwestheim, D-74382 (Germany); Kockelmann, H. [Staatliche Materialpruefungsanstalt (MPA), University of Stuttgart, Stuttgart (Germany)

    1995-10-01

    The Atomic Energy Act requires that measures made feasible by state of the art technology be adopted to avoid damage that could be caused as the result of the construction and operation of a nuclear plant. This stipulation constitutes the basis for deriving requirements for planning, design, construction, operation and decommissioning. Ensuring the function and integrity of those components and systems that are relevant to plant safety is of major significance with regard to operation of a nuclear power plant. The basis for ensuring these features is laid in planning, design and construction. Important as these foundations may be, it is absolutely essential to monitor the quality originally planned and achieved in an object as undeniably complex as a nuclear power plant. The RSK-Leitlinien fuer Druckwasserreaktoren (Reactor Safety Commission Guidelines for Pressurized Water Reactors) incorporate fundamental requirements for design, mechanical design, materials, manufacturing, testing and examination, and operation. Meeting these requirements makes it possible to exclude a catastrophic rupture of the components in the reactor cooling system pressure boundary (primary system), as has been demonstrated in detailed research and development work. The term basic safety was defined for this concept. Basic safety coupled with multiple redundancy suffices to exclude the possibility of large ruptures (rupture preclusion). The principle of plant monitoring and documentation (operational monitoring) implements redundancy in a significant manner within this concept. The monitoring techniques used in Germany have reached an advanced state of development and are still being optimized. Thus, operational monitoring is a major contributory factor in the safety and high availability of nuclear power plants. It also provides a means of expanding our knowledge of life time expectation. (orig.).

  19. Design and evaluation of a high temperature/pressure supercritical carbon dioxide direct tubular receiver for concentrating solar power applications

    Science.gov (United States)

    Ortega, Jesus Daniel

    This work focuses on the development of a solar power thermal receiver for a supercritical-carbon dioxide (sCO2), Brayton power-cycle to produce ~1 MWe. Closed-loop sCO2 Brayton cycles are being evaluated in combination with concentrating solar power to provide higher thermal-to-electric conversion efficiencies relative to conventional steam Rankine cycles. High temperatures (923--973 K) and pressures (20--25 MPa) are required in the solar receiver to achieve thermal efficiencies of ~50%, making concentrating solar power (CSP) technologies a competitive alternative to current power generation methods. In this study, the CSP receiver is required to achieve an outlet temperature of 923 K at 25 MPa or 973 K at 20 MPa to meet the operating needs. To obtain compatible receiver tube material, an extensive material review was performed based the ASME Boiler and Pressure Vessel Code, ASME B31.1 and ASME B313.3 codes respectively. Subsequently, a thermal-structural model was developed using a commercial computational fluid (CFD) dynamics and structural mechanics software for designing and analyzing the tubular receiver that could provide the heat input for a ~2 MWth plant. These results were used to perform an analytical cumulative damage creep-fatigue analysis to estimate the work-life of the tubes. In sequence, an optical-thermal-fluid model was developed to evaluate the resulting thermal efficiency of the tubular receiver from the NSTTF heliostat field. The ray-tracing tool SolTrace was used to obtain the heat-flux distribution on the surfaces of the receiver. The K-ω SST turbulence model and P-1 radiation model used in Fluent were coupled with SolTrace to provide the heat flux distribution on the receiver surface. The creep-fatigue analysis displays the damage accumulated due to the cycling and the permanent deformation of the tubes. Nonetheless, they are able to support the required lifetime. The receiver surface temperatures were found to be within the safe

  20. Intelligent control system for the temperature regulation in a gas turbine of a combined cycle fossil fuel power plant; Sistema de control inteligente para regular la temperatura en la turbina de gas de una central termoelectrica de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Espindola Vasquez, Agustin

    2004-11-15

    In the Turbogas Units (UTG short for Spanish acronym) of a Thermoelectric Power station of Combined Cycle (CTCC short for Spanish acronym), from an operative, as well as a safety standpoint the turbine blade temperature is a critical variable. The best performance of a turbogas unit based in the electrical generation is obtained when the greatest thermal efficiency is reached. From the point of view of safety, it is desirable to keep the blades temperature at the limit established by the manufacturer, guaranteeing with this, the integrity of the UTG internal parts; avoiding that great thermal efforts decrease their useful life. In order to keep the blades temperature at the established limit, the UTG control system have a supervision system of blades temperature, that system modifies the controllers reference of the speed or power PI's which regulate the fuel valve of the UTG combustion chamber. This supervision system is based on logic conditions to generate its exit signal. In the process plants whose operation is complex and its dynamic behavior is nonlinear, the strategies of control of single loop do not provide the wished performance when they are applied in control loops to regulate critical variables; thing doing necessary the design of structures with two hierarchical levels; one with direct control and the other with supervisory control. The fuzzy logic has found a wide acceptance [Chiu, 1998] when is used to handle control functions of high level which are outside of the dominion of the conventional control methods. One of these cases is the application of the fuzzy logic to the supervisory control. In this thesis document is presented the accomplishment of a temperature fuzzy supervision system in a turbogas unit, whose purpose is to keep the turbine blades temperature within the established limits, conserving a satisfactory performance from an operative, as well as a safety standpoint. The temperature supervisor was designed with base on fuzzy

  1. Laser Power Transmission Employing a Dual-Use Photovoltaic Concentrator at the Receiving End Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is a wireless laser power transmission system employing a dual-use photovoltaic concentrator at the receiving end. Specifically, the laser...

  2. Maximisation of Combined Cycle Power Plant Efficiency

    Directory of Open Access Journals (Sweden)

    Janusz Kotowicz

    2015-12-01

    Full Text Available The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.

  3. DCS emulator development for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Y. [Hitachi Canada Ltd., Power and Industry Div., Mississauga, Ontario (Canada); Ishii, K.; Chiba, D. [Hitachi Ltd., Information and Control Systems Div., Ibaraki-ken (Japan)

    2009-07-01

    Continual training of operators is one of the principal means by which Nuclear Power Plant (NPP) operational efficiency can be improved. Since this training cannot take place in the actual NPP, NPP simulator applications must be used instead. While digitalization scope of Instrumentation and Control (I and C) systems has been expanded to the entire plant by using Distributed Control System (DCS) implementation, Hitachi has implemented DCS emulator on a general purpose Personal Computer (PC) and applied it to simulator applications. This paper reviews such DCS emulator development for NPP by Hitachi. (author)

  4. Coal Moisture Estimation in Power Plant Mills

    DEFF Research Database (Denmark)

    Andersen, Palle; Bendtsen, Jan Dimon; Pedersen, Tom S.;

    2009-01-01

    Knowledge of moisture content in raw coal feed to a power plant coal mill is of importance for efficient operation of the mill. The moisture is commonly measured approximately once a day using offline chemical analysis methods; however, it would be advantageous for the dynamic operation...... of the plant if an on-line estimate were available. In this paper we such propose an on-line estimator (an extended Kalman filter) that uses only existing measurements. The scheme is tested on actual coal mill data collected during a one-month operating period, and it is found that the daily measured moisture...

  5. Electric power plant emissions and public health

    Energy Technology Data Exchange (ETDEWEB)

    O' Connor, A.B.; Roy, C. [Faculty of Maine Dartmouth Family Medical Residency, Fairfield, ME (United States)

    2008-02-15

    The generation of electric power is one important source of pollutants such as mercury, sulfur dioxide, nitrogen oxides, and fine particulate matter that can affect the respiratory, cardiovascular, and central nervous systems and cause pregnancy complications. But protecting people from environmental health hazards has become increasingly complex. Air pollutants are often invisible and travel many miles virtually undetected. Nurses can play a critical role in preventive strategies, as well as in the national debate on energy production and dependence on fossil fuels.

  6. Evaluation of creep-fatigue life-prediction models for the solar central receiver

    Science.gov (United States)

    Hyzak, J. M.; Hughes, D. A.

    1981-09-01

    The applicability of several creep fatigue models to life prediction of boiler tubes in a solar central receiver (SCR) was evaluated. The SCR boiler tubes will experience compressive strain dwell loading with hold times up to 6 to 8 hours at temperatures where time dependent deformation will occur. The evaluation criteria include the ability of the model to account for mean stress effects and to be practical in the long life, small strain range regime. A correlation between maximum tensile stress and fatigue life is presented. Using this correlation, compressive dwell behavior is predicted based on continuous cycling data. The limits of this predictive scheme are addressed.

  7. Estimation of requirements of eolic energy equivalent to the electric generation of the Laguna Verde nuclear power plant; Estimacion de requerimientos de energia eolica equivalente a la generacion electrica de la Central Nucleoelectrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A.; Hernandez M, I.A. [Facultad de Ingenieria, Division de Ingenieria Electrica, UNAM, 04510 Mexico D.F. (Mexico)]. E-mail: maiki27@yahoo.com; Martin del Campo M, C. [Facultad de Ingenieria, Laboratorio de Analisis en Ingenieria de Reactores Nucleares, UNAM, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Morelos (Mexico)

    2004-07-01

    The advantages are presented that have the nuclear and eolic energy as for their low environmental impact and to the human health. An exercise is presented in the one that is supposed that the electric power generated by the Laguna Verde Nuclear Power plant (CNLV), with capacity of 1365 M W, it should be produced by eolic energy when in the years 2020 and 2025 the units 1 and 2 of the CNLV reach its useful life and be moved away. It is calculated the number of aero generators that would produce the electric power average yearly of the CNLV, that which is equal to install eolic parks with capacity of 2758 M W, without considering that it will also be invested in systems of back generation to produce electricity when the aero generators stops for lack of wind. (Author)

  8. Fault diagnosis in the steam turbo-generator of a Combined Cycle Power Plant; Diagnostico de fallas en el turbogenerador a vapor de una central de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Flores Abad, Angel

    2006-12-15

    Due to the physical nature of its components, technological processes are vulnerable to faults. These faults affect the accurate behavior of the system, causing a performance reduction, even great economical losses and in the worst case environmental and human disasters. The opportune detection of the presence of faults helps to take corrective actions and as a consequence to reduce the potential damage that faults cause. To achieve the fault detection task, technological processes have supervisory systems to monitor the process variables and provide an alarm when a variable reached a given threshold. This method has the drawback that a single fault could cause many system alarms, which difficult the fault isolation. In addition it is based on hardware redundancy; it means the use of repeated devices to do the same work. Combined cycle power plants (CCPP) are large scale systems with a high degree of fault susceptibility. Due to strict conditions in which they operate and the great number of elements they contain, including sensors and actuators. Nowadays this kind of power plants tends to dominate the electric generation market by means of fossil fuels, because they are the most efficient, profitable, with flexible operation and with less environmental impact. In the CCPP, the steam turbine (ST) is a fundamental component, since it represents the process gain, in the way that it allows the generation of additional electric energy by taking advantage of the exhaust gases of the gas turbines. In case of the ST fails, the global efficiency of the process is reduced even in a 40%. In this work a model based fault diagnosis system was developed, according to the FDI (Fault Detection and Isolation) methodology of the control theory, with the capability of detecting and isolating faults in the sensors and actuators of the ST of a CCPP. The developed system is based on the analytical redundancy which allows optimizing the hardware redundancy and getting a reduction of the

  9. Improved repowering techniques for power plants

    DEFF Research Database (Denmark)

    Houbak, Niels; Andersen, Simon E.; Petersen, Stiig Bo;

    1998-01-01

    Repowering of existing coal-fired power plants is often accomplished by adding gas turbines. In this paper we assume that the gas turbine exhaust is used for feed water preheating.Typical gas turbine exhaust temperatures are in the range 450-600C whereas typical boiler inlet temperatures are 250......-300C. The big difference in temperature between exhaust and water prevents an efficient exchange of heat. One way to lower the exhaust temperature is to expand the gas to sub atmospheric pressure. The result is a 50% increase in possible installed gas turbine power....

  10. FACTS Devices for Large Wind Power Plants

    DEFF Research Database (Denmark)

    Adamczyk, Andrzej Grzegorz; Teodorescu, Remus; Rodriguez, Pedro;

    2010-01-01

    Growing number of wind turbines is changing electricity generation profile all over the world. However, high wind energy penetration affects power system safety and stability. For this reason transmission system operators (TSO) impose more stringent connection requirements on the wind power plant...... (WPP) owners. On the other hand flexible AC transmission systems (FACTS) devices offer enhancement of grid stability and can facilitate grid code compliance for WPP. In this paper state-of-the-art in FACTS for large WPPs with AC connection is given. FACTS devices (excluding HVDC) with their properties...... are described. Academic and industrial research in FACTS applicability for WPPs is summarized....

  11. Analysis of environmental impact phase in the life cycle of a nuclear power plant; Analisis de la fase de impacto ambiental en el ciclo de vida de una central nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez del M, C.

    2015-07-01

    The life-cycle analysis covers the environmental aspects of a product throughout its life cycle. The focus of this study was to apply a methodology of life-cycle analysis for the environmental impact assessment of a nuclear power plant by analyzing international standards ISO 14040 and 14044. The methodology of life-cycle analysis established by the ISO 14044 standard was analyzed, as well as the different impact assessment methodologies of life cycle in order to choose the most appropriate for a nuclear power plant; various tools for the life-cycle analysis were also evaluated, as is the use of software and the use of databases to feed the life cycle inventory. The functional unit chosen was 1 KWh of electricity, the scope of analysis ranging from the construction and maintenance, disposal of spent fuel to the decommissioning of the plant, the manufacturing steps of the fuel were excluded because in Mexico is not done this stage. For environmental impact assessment was chosen the Recipe methodology which evaluates up to 18 impact categories depending on the project. In the case of a nuclear power plant were considered only categories of depletion of the ozone layer, climate change, ionizing radiation and formation of particulate matter. The different tools for life-cycle analysis as the methodologies of impact assessment of life cycle, different databases or use of software have been taken according to the modeling of environmental sensitivities of different regions, because in Mexico the methodology for life-cycle analysis has not been studied and still do not have all the tools necessary for the evaluation, so the uncertainty of the data supplied and results could be higher. (Author)

  12. Design of a photovoltaic central power station: flat-plate array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using fixed flat-panel arrays has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes high-efficiency photovoltaic modules using dendritic web cells. The modules are arranged in 5 MW subfields, each with its own power conditioning unit. The photovoltaic output is connected to the existing 115 kV utility switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  13. Centrality Fingerprints for Power Grid Network Growth Models

    CERN Document Server

    Gurfinkel, Aleks Jacob; Rikvold, Per Arne

    2015-01-01

    In our previous work, we have shown that many of the properties of the Florida power grid are reproduced by deterministic network growth models based on the minimization of energy dissipation $E_\\mathrm{diss}$. As there is no $a~ priori$ best $E_\\mathrm{diss}$ minimizing growth model, we here present a tool, called the "centrality fingerprint," for probing the behavior of different growth models. The centrality fingerprints are comparisons of the current flow into/out of the network with the values of various centrality measures calculated at every step of the growth process. Finally, we discuss applications to the Maryland power grid.

  14. Internal event analysis for Laguna Verde Unit 1 Nuclear Power Plant. Accident sequence quantification and results; Analisis de eventos internos para la Unidad 1 de la Central Nucleoelectrica de Laguna Verde. Cuantificacion de secuencias de accidente y resultados

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1994-07-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the {sup I}nternal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant, CNSNS-TR 004, in five volumes. The reports are organized as follows: CNSNS-TR 004 Volume 1: Introduction and Methodology. CNSNS-TR4 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR 004 Volume 3: System Analysis. CNSNS-TR 004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR 005 Volume 5: Appendices A, B and C. This volume presents the development of the dependent failure analysis, the treatment of the support system dependencies, the identification of the shared-components dependencies, and the treatment of the common cause failure. It is also presented the identification of the main human actions considered along with the possible recovery actions included. The development of the data base and the assumptions and limitations in the data base are also described in this volume. The accident sequences quantification process and the resolution of the core vulnerable sequences are presented. In this volume, the source and treatment of uncertainties associated with failure rates, component unavailabilities, initiating event frequencies, and human error probabilities are also presented. Finally, the main results and conclusions for the Internal Event Analysis for Laguna Verde Nuclear Power Plant are presented. The total core damage frequency calculated is 9.03x 10-5 per year for internal events. The most dominant accident sequences found are the transients involving the loss of offsite power, the station blackout accidents, and the anticipated transients without SCRAM (ATWS). (Author)

  15. Technical and economic proposal for the extension of the Laguna Verde Nuclear Power plant with an additional nuclear reactor; Propuesta tecnica y economica para la ampliacion de la Central Nucleoelectrica Laguna Verde con un reactor nuclear adicional

    Energy Technology Data Exchange (ETDEWEB)

    Leal C, C.D.; Francois L, J.L. [Facultad de Ingenieria, UNAM, Circuito Interior, C.U. Coyoacan, 04510 Mexico D.F. (Mexico)]. e-mail: carlosdanielleal@yahoo.com.mx

    2006-07-01

    The increment of the human activities in the industrial environments and of generation of electric power, through it burns it of fossil fuels, has brought as consequence an increase in the atmospheric concentrations of the calls greenhouse effect gases and, these in turn, serious repercussions about the environment and the quality of the alive beings life. The recent concern for the environment has provoked that industrialized countries and not industrialized carry out international agreements to mitigate the emission from these gases to the atmosphere. Our country, like part of the international community, not is exempt of this problem for what is necessary that programs begin guided toward the preservation of the environment. As for the electric power generation, it is indispensable to diversify the sources of primary energy; first, to knock down the dependence of the hydrocarbons and, second, to reduce the emission of polluting gases to the atmosphere. In this item, the nucleo electric energy not only has proven to be safe and competitive technical and economically, able to generate big quantities of electric power with a high plant factor and a considerable cost, but rather also, it is one of the energy sources that less pollutants it emits to the atmosphere. The main object of this work is to carry out a technical and economic proposal of the extension of the Laguna Verde Nuclear power plant (CNLV) with a new nuclear reactor of type A BWR (Advanced Boiling Water Reactor), evolutionary design of the BWR technology to which belong the two reactors installed at the moment in the plant, with the purpose of increasing the installed capacity of generation of the CNLV and of the Federal Commission of Electricity (CFE) with foundation in the sustainable development and guaranteeing the protection of the environment by means of the exploitation of a clean and sure technology that counts at the moment with around 12,000 year-reactor of operational experience in more of

  16. Thermodynamics in nuclear power plant systems

    CERN Document Server

    Zohuri, Bahman

    2015-01-01

    This book covers the fundamentals of thermodynamics required to understand electrical power generation systems, honing in on the application of these principles to nuclear reactor powersystems. It includes all the necessary information regarding the fundamental laws to gain a complete understanding and apply them specifically to the challenges of operating nuclear plants. Beginning with definitions of thermodynamic variables such as temperature, pressure and specific volume, the book then explains the laws in detail, focusing on pivotal concepts such as enthalpy and entropy, irreversibilit

  17. Safety in nuclear power plants in India

    OpenAIRE

    Deolalikar R

    2008-01-01

    Safety in nuclear power plants (NPPs) in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operat...

  18. Virtual power plants with electric vehicles

    OpenAIRE

    Grau, Iñaki; Papadopoulos, Panagiotis; Skarvelis-Kazakos, Spyros; Cipcigan, Liana M.; Jenkins, Nick

    2010-01-01

    The benefits of integrating aggregated Electric Vehicles (EV) within the Virtual Power Plant (VPP) concept, are addressed. Two types of EV aggregators are identified: i) Electric Vehicle Residential Aggregator (EVRA), which is responsible for the management of dispersed and clustered EVs in a residential area and ii) Electric Vehicle Commercial Aggregator (EVCA), which is responsible for the management of EVs clustered in a single car park. A case study of a workplace EVCA is presented, provi...

  19. Alloy Design for a Fusion Power Plant

    OpenAIRE

    Kemp, Richard

    2006-01-01

    Fusion power is generated when hot deuterium and tritium nuclei react, producing alpha particles and 14 MeV neutrons. These neutrons escape the reaction plasma and are absorbed by the surrounding material structure of the plant, transferring the heat of the reaction to an external cooling circuit. In such high-energy neutron irradiation environments, extensive atomic displacement damage and transmutation production of helium affect the mechanical properties of materials. Among these effect...

  20. Advanced Power Plant Development and Analysis Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    A.D. Rao; G.S. Samuelsen; F.L. Robson; B. Washom; S.G. Berenyi

    2006-06-30

    Under the sponsorship of the U.S. Department of Energy/National Energy Technology Laboratory, a multi-disciplinary team led by the Advanced Power and Energy Program of the University of California at Irvine is defining the system engineering issues associated with the integration of key components and subsystems into advanced power plant systems with goals of achieving high efficiency and minimized environmental impact while using fossil fuels. These power plant concepts include 'Zero Emission' power plants and the 'FutureGen' H2 co-production facilities. The study is broken down into three phases. Phase 1 of this study consisted of utilizing advanced technologies that are expected to be available in the 'Vision 21' time frame such as mega scale fuel cell based hybrids. Phase 2 includes current state-of-the-art technologies and those expected to be deployed in the nearer term such as advanced gas turbines and high temperature membranes for separating gas species and advanced gasifier concepts. Phase 3 includes identification of gas turbine based cycles and engine configurations suitable to coal-based gasification applications and the conceptualization of the balance of plant technology, heat integration, and the bottoming cycle for analysis in a future study. Also included in Phase 3 is the task of acquiring/providing turbo-machinery in order to gather turbo-charger performance data that may be used to verify simulation models as well as establishing system design constraints. The results of these various investigations will serve as a guide for the U. S. Department of Energy in identifying the research areas and technologies that warrant further support.

  1. Advanced Power Plant Development and Analyses Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    G.S. Samuelsen; A.D. Rao

    2006-02-06

    Under the sponsorship of the U.S. Department of Energy/National Energy Technology Laboratory, a multi-disciplinary team led by the Advanced Power and Energy Program of the University of California at Irvine is defining the system engineering issues associated with the integration of key components and subsystems into advanced power plant systems with goals of achieving high efficiency and minimized environmental impact while using fossil fuels. These power plant concepts include ''Zero Emission'' power plants and the ''FutureGen'' H{sub 2} co-production facilities. The study is broken down into three phases. Phase 1 of this study consisted of utilizing advanced technologies that are expected to be available in the ''Vision 21'' time frame such as mega scale fuel cell based hybrids. Phase 2 includes current state-of-the-art technologies and those expected to be deployed in the nearer term such as advanced gas turbines and high temperature membranes for separating gas species and advanced gasifier concepts. Phase 3 includes identification of gas turbine based cycles and engine configurations suitable to coal-based gasification applications and the conceptualization of the balance of plant technology, heat integration, and the bottoming cycle for analysis in a future study. Also included in Phase 3 is the task of acquiring/providing turbo-machinery in order to gather turbo-charger performance data that may be used to verify simulation models as well as establishing system design constraints. The results of these various investigations will serve as a guide for the U. S. Department of Energy in identifying the research areas and technologies that warrant further support.

  2. Comparison of Square and Radial Geometries for High Intensity Laser Power Beaming Receivers

    Science.gov (United States)

    Raible, Daniel E.; Fast, Brian R.; Dinca, Dragos; Nayfeh, Taysir H.; Jalics, Andrew K.

    2012-01-01

    In an effort to further advance a realizable form of wireless power transmission (WPT), high intensity laser power beaming (HILPB) has been developed for both space and terrestrial applications. Unique optical-to-electrical receivers are employed with near infrared (IR-A) continuous-wave (CW) semiconductor lasers to experimentally investigate the HILPB system. In this paper, parasitic feedback, uneven illumination and the implications of receiver array geometries are considered and experimental hardware results for HILPB are presented. The TEM00 Gaussian energy profile of the laser beam presents a challenge to the effectiveness of the receiver to perform efficient photoelectric conversion, due to the resulting non-uniform illumination of the photovoltaic cell arrays. In this investigation, the geometry of the receiver is considered as a technique to tailor the receiver design to accommodate the Gaussian beam profile, and in doing so it is demonstrated that such a methodology is successful in generating bulk receiver output power levels reaching 25 W from 7.2 sq cm of photovoltaic cells. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers to achieve a 1.0 sq m receiver capable of generating over 30 kW of electrical power. This type of system would enable long range optical "refueling" of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion. In addition, a smaller HILPB receiver aperture size could be utilized to establish a robust optical communications link within environments containing high levels of background radiance, to achieve high signal to noise ratios.

  3. Fatigue monitoring in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Shah, V.N. [Idaho National Engineering Laboratory, Idaho Falls, ID (United States)

    1995-04-01

    This paper summarizes fatigue monitoring methods and surveys their application in the nuclear power industry. The paper is based on a review of the technical literature. Two main reasons for fatigue monitoring are more frequent occurrence of some transients than that assumed in the fatigue design analysis and the discovery of stressors that were not included in the fatigue design analysis but may cause significant fatigue damage at some locations. One fatigue monitoring method involves use of plant operating data and procedures to update the fatigue usage. Another method involves monitoring of plant operating parameters using existing, or if needed, supplementary plant instrumentation for online computation of fatigue usage. Use of fatigue monitoring has better defined the operational transients. Most operational transients have been found less severe and fewer in numbers than anticipated in the design fatigue analysis. Use of fatigue monitoring has assisted in quantifying newly discovered stressors and has helped in detecting the presence of thermal stratification of unsuspected locations.

  4. Construct ability Improvement for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dae Soo; Lee, Jong Rim; Kim, Jong Ku [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The purpose of this study was to identify methods for improving the construct ability of nuclear power plants. This study reviewed several references of current construction practices of domestic and overseas nuclear plants in order to identify potential methods for improving construct ability. The identified methods for improving construct ability were then evaluated based on the applicability to domestic nuclear plant construction. The selected methods are expected to reduce the construction period, improve the quality of construction, cost, safety, and productivity. Selection of which methods should be implemented will require further evaluation of construction modifications, design changes, contract revisions. Among construction methods studied, platform construction methods can be applied through construction sequence modification without significant design changes, and Over the Top construction method of the NSSS, automatic welding of RCL pipes, CLP modularization, etc., are considered to be applied after design modification and adjustment of material lead time. (author). 49 refs., figs., tabs.

  5. Reflectance measurement in heliostats field of Solar Thermal Central Receivers Systems; Medida de reflectancia en campos de heliostatos de sistemas de Torre Central

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Monterreal, R.

    2004-07-01

    Determination of the mean reflectance of Heliostats field of Solar Thermal Central Receivers Systems takes high relevance, from both the operational point of view and the components evaluation. To calculate the mean reflectance calculation becomes essential to establish a procedure that allows offering its value without measuring all and each one of the facets that constitute the field, since this is a long-time consuming and little operational task. This work presents the results of the statistical reflectance study of the CRS heliostats field of the Plataforma Solar de Almeria. In addition, to validate the results, the obtained average reflectance is introduced in the heliostats field simulation code Fiat{sub L}ux. A comparison between the simulation and real incident solar power measurement was performed. (Author)

  6. Simulation and experimental research of 1MWe solar tower power plant in China

    Science.gov (United States)

    Yu, Qiang; Wang, Zhifeng; Xu, Ershu

    2016-05-01

    The establishment of a reliable simulation system for a solar tower power plant can greatly increase the economic and safety performance of the whole system. In this paper, a dynamic model of the 1MWe Solar Tower Power Plant at Badaling in Beijing is developed based on the "STAR-90" simulation platform, including the heliostat field, the central receiver system (water/steam), etc. The dynamic behavior of the global CSP plant can be simulated. In order to verify the validity of simulation system, a complete experimental process was synchronously simulated by repeating the same operating steps based on the simulation platform, including the locations and number of heliostats, the mass flow of the feed water, etc. According to the simulation and experimental results, some important parameters are taken out to make a deep comparison. The results show that there is good alignment between the simulations and the experimental results and that the error range can be acceptable considering the error of the models. In the end, a comprehensive and deep analysis on the error source is carried out according to the comparative results.

  7. Methodology for Assessment of Inertial Response from Wind Power Plants

    DEFF Research Database (Denmark)

    Altin, Müfit; Teodorescu, Remus; Bak-Jensen, Birgitte;

    2012-01-01

    High wind power penetration levels result in additional requirements from wind power in order to improve frequency stability. Replacement of conventional power plants with wind power plants reduces the power system inertia due to the wind turbine technology. Consequently, the rate of change...

  8. Scaling of a break small in the hot field of the LSTF installation to a nuclear power plant; Escalado de una rotura pequena en la rama caliente de la instacions LSTF a una central nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Querol, A.; Gallardo, S.; Verdu, G.

    2014-07-01

    The objective of this work is to study if the phenomenology observed during in one break small in the hot branch of a small scale, such as Large Scale Test installation Facility (LSTF), can be extrapolated to a real plant. To do so, is considered the experiment 1-2 of the OECD/NEA rose, which simulates a break in the hot field of 1%, and the code project Thermo-hydraulic TRACE5 to reproduce the LSTF facility and a real plant and thus, power compare the results. They have been considered two models for the actual plant: a scaled model of the LSTF facility while preserving the relationship of power and volume of original LSTF and a typical model Westinghouse PWR of 3 loops. The results obtained show that the scaling LSTF and LSTF installation models reproduce the same behavior during the transient. However, with the Westinghouse model 3 ties there are important differences. The most important thing is that natural circulation does not play properly. The effect of the nodalization of U-tubes and the vessel has been in improving outcomes. The results obtained show that the nodalization of U-tubes affects the reproduction of natural circulation, while the nodalization of the vessel does not have a relevant effect. (Author)

  9. Modernization of the Electric Power Systems (transformers, rods and switches) in the Laguna Verde Nuclear Power Plant (Mexico); Modernizacion de los Sistemas Electricos de Potencia (Transformadores de Principales, Interruptor de Generacion, Barras de Fase Aislada) de la Central Nuclear de Laguna Verde (Mexico)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Solarzano, J. J.; Gabaldon Martin, M. A.; Pallisa Nunez, J.; Florez Ordeonez, A.; Fernandez Corbeira, A.; Prieto Diez, I.

    2010-07-01

    Description of the changes made in the Electric Power Systems as a part of the power increase project in the Laguna Verde Nuclear Power Plant (Mexico). The main electrical changes to make, besides the turbo group, are the main generation transformers, the isolated rods and the generation switch.

  10. Experiences in the implementation of the Coaching project in the nuclear power plant of Laguna Verde (NPP-L V); Experiencias en la implementacion del proyecto Coaching en la Central Nucleoelectrica Laguna Verde (CNLV)

    Energy Technology Data Exchange (ETDEWEB)

    Mendez M, H. I., E-mail: hugo.mendez01@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Departamento del Centro de Entrenamiento, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2012-10-15

    This document has the purpose of to share acquired experiences during the implementation of the Coaching project focused the training of supervisors and directive personnel of the nuclear power plant of Laguna Verde (NPP-L V). Derived of the improvement areas identified by the supervisor organization of the nuclear power stations WANO (World Association Nuclear of Operators) and of the auto-evaluations realized by the expert personnel of the same power station that based on external experiences carried out through the Benchmarking (comparison with other power stations) they have reflected the necessity to activate a training process in Coaching with a practical focus toward the directive and supervisor personnel in the power station. By means of the observation of the personnel's acting so much in the control rooms like in different areas, three focus areas have been identified for the training in Coaching, these are the personnel's motivation, the organizational communication so much in vertical form as horizontal and the perception of confidence lack among directive, supervisors, operators and technicians. The plan focused in the abilities training of Coaching with practical sense was development, supported with an evaluation of 360 grades as tool of competitions development through a computer application e-Coaching. The use of application and Coaching following techniques facilitated the conformation of the practical focus, same that are of continuous use starting from the training of the supervisor and directive personnel. (Author)

  11. Negative sequence relay applied to generator 1 of the Laguna Verde nuclear power plant; Aplicacion de un relevador de secuencia negativa en el generador 1 de la central de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Diaz de la Serna P, Enrique [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    The rotor of a synchronous generator can be dangerously heated in a short time by stator current unbalance, therefore it must be protected with a specific relay. This article discusses the protection and the adjustments selected for Unit 1 of the Comision Federal de Electricidad Laguna Verde Nuclear Nuclear Power Station. [Espanol] El rotor de un generador sincrono puede calentarse peligrosamente en un tiempo corto debido a desbalance de corrientes en el estator, por lo que debe protegerse con un relevador especifico. En este articulo se describen la proteccion y los ajustes seleccionados para la unidad 1, de la central nucleoelectrica Laguna Verde de la Comision Federal de Electricidad.

  12. Joint Downlink Power Control and Multicode Receivers for Downlink Transmissions in High Speed UMTS

    Directory of Open Access Journals (Sweden)

    Sayadi Bessem

    2006-01-01

    Full Text Available We propose to combine the gains of a downlink power control and a joint multicode detection, for an HSDPA link. We propose an iterative algorithm that controls both the transmitted code powers and the joint multicode receiver filter coefficients for the high-speed multicode user. At each iteration, the receiver filter coefficients of the multicode user are first updated (in order to reduce the intercode interferences and then the transmitted code powers are updated, too. In this way, each spreading code of the multicode scheme creates the minimum possible interference to others while satisfying the quality of service requirement. The main goals of the proposed algorithm are on one hand to decrease intercode interference and on the other hand to increase the system capacity. Analysis for the rake receiver, joint multicode zero forcing (ZF receiver, and joint multicode MMSE receiver is presented. Simulation is used to show the convergence of the proposed algorithm to a fixed point power vector where the multicode user satisfies its signal-to-interference ratio (SIR target on each code. The results show the convergence behavior for the different receivers as the number of codes increases. A significant gain in transmitted base station power is obtained.

  13. An Approach to Calculate the Efficiency for an N-Receiver Wireless Power Transfer System

    Directory of Open Access Journals (Sweden)

    Thabat Thabet

    2015-09-01

    Full Text Available A wireless power transfer system with more than one receiver is a realistic proposition for charging multiple devices such as phones and a tablets. Therefore, it is necessary to consider systems with single transmitters and multiple receivers in terms of efficiency. Current offerings only consider single device charging systems. A problem encountered is the efficiency of one receiver can be affected by another because of the mutual inductance between them. In this paper, an efficiency calculation method is presented for a wireless power transfer system with one to N-receivers. The mutual inductance between coils is implicitly calculated for different spatial positions and verified by practical experimentation. The effect of changing parameters, such as resonant frequency, coil size and distance between coils, on the efficiency has been studied. A clarification of the special performance of a wireless power transfer system at a specific point has been presented.

  14. Efficient MIMO-OFDM Schemes for Future Terrestrial Digital TV with Unequal Received Powers

    CERN Document Server

    Nasser, Youssef; Crussière, Matthieu; Pasquero, Oudomsack

    2008-01-01

    This article investigates the effect of equal and unequal received powers on the performances of different MIMO-OFDM schemes for terrestrial digital TV. More precisely, we focus on three types of non-orthogonal schemes: the BLAST scheme, the Linear Dispersion (LD) code and the Golden code, and we compare their performances to that of Alamouti scheme. Using two receiving antennas, we show that for moderate attenuation on the second antenna and high spectral efficiency, Golden code outperforms other schemes. However, Alamouti scheme presents the best performance for low spectral efficiency and equal received powers or when one antenna is dramatically damaged. When three antennas are used, we show that Golden code offers the highest robustness to power unbalance at the receiving side

  15. Constraining the Lithospheric Structure of the Central Andes Using P- and S- wave Receiver Functions

    Science.gov (United States)

    Ryan, J. C.; Beck, S. L.; Zandt, G.; Wagner, L. S.; Minaya, E.; Tavera, H.

    2014-12-01

    The Central Andean Plateau (CAP) has elevations in excess of 3 km, and is part of the Andean Cordillera that resulted in part from shortening along the western edge of South America as it was compressed between the subducting Nazca plate and underthrusting Brazilian cratonic lithosphere. We calculated P- and S-wave receiver functions for the Central Andean Uplift and Geodynamics of High Topography (CAUGHT) temporary deployment of broadband seismometers in the Bolivian orocline (12°-20°S) region to investigate crustal thickness and lithospheric structure. Migration of the receiver functions is done using common conversion point (CCP) stacks through a 3D shear velocity model from ambient noise tomography (Ward et al., 2013). The P- and S-wave receiver functions provide similar estimates of the depth to Moho under the CAP. Crustal thicknesses include 60-65 km thick crust underneath the Bolivian Altiplano, crust that varies from ~70 km to ~50 km underneath the Eastern Cordillera and Interandean zone, and thins to 50 to 40 km crust in the Subandes and the edge of the foreland. The variable crustal thickness of the Eastern Cordillera and Interandean zone ranges from >70 km associated with the Los Frailes volcanic field at 19°-20°S to ~55 km beneath the 6 km peaks of the Cordillera Real at ~16°S. From our S-wave receiver functions, that have no multiples that can interfere with deeper structure, we also identify structures below the Moho. Along a SW-NE line that runs near La Paz where we have our highest station density, the S-wave CCP receiver-function stacks show a strong negative polarity arrival at a depth of ~120 km from the eastern edge of the Altiplano to the Subandean zone. We suggest this may be a good candidate for the base of the CAP lithosphere. In addition, above this depth the mantle is strongly layered, suggesting that there is not a simple high velocity mantle lithosphere associated with the continental lithosphere underthrusting the Andean orogen

  16. EDITORIAL: Safety aspects of fusion power plants

    Science.gov (United States)

    Kolbasov, B. N.

    2007-07-01

    This special issue of Nuclear Fusion contains 13 informative papers that were initially presented at the 8th IAEA Technical Meeting on Fusion Power Plant Safety held in Vienna, Austria, 10-13 July 2006. Following recommendation from the International Fusion Research Council, the IAEA organizes Technical Meetings on Fusion Safety with the aim to bring together experts to discuss the ongoing work, share new ideas and outline general guidance and recommendations on different issues related to safety and environmental (S&E) aspects of fusion research and power facilities. Previous meetings in this series were held in Vienna, Austria (1980), Ispra, Italy (1983), Culham, UK (1986), Jackson Hole, USA (1989), Toronto, Canada (1993), Naka, Japan (1996) and Cannes, France (2000). The recognized progress in fusion research and technology over the last quarter of a century has boosted the awareness of the potential of fusion to be a practically inexhaustible and clean source of energy. The decision to construct the International Thermonuclear Experimental Reactor (ITER) represents a landmark in the path to fusion power engineering. Ongoing activities to license ITER in France look for an adequate balance between technological and scientific deliverables and complying with safety requirements. Actually, this is the first instance of licensing a representative fusion machine, and it will very likely shape the way in which a more common basis for establishing safety standards and policies for licensing future fusion power plants will be developed. Now that ITER licensing activities are underway, it is becoming clear that the international fusion community should strengthen its efforts in the area of designing the next generations of fusion power plants—demonstrational and commercial. Therefore, the 8th IAEA Technical Meeting on Fusion Safety focused on the safety aspects of power facilities. Some ITER-related safety issues were reported and discussed owing to their potential

  17. 75 FR 14436 - Ameren Corporation, Illinois Power Company, Central Illinois Light Company, Central Illinois...

    Science.gov (United States)

    2010-03-25

    ... Energy Regulatory Commission Ameren Corporation, Illinois Power Company, Central Illinois Light Company, Central Illinois Public Service Company, Ameren Energy Resources Company, LLC, AmerenEnergy Resources Generating Company; Notice of Filing March 18, 2010. Take notice that on March 15, 2010, Ameren...

  18. Sampling and description of the resins stockpiles in the Kozloduy Nuclear Power Plant large tanks; Muestreo y caracterizacion de resinas almacenadas en tanques de grandes dimensiones de la Central Nuclear de Kozloduy (Bulgaria)

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Fernandez, L.; Gonzalez Gandal, R.; Herrera, J. A.

    2012-11-01

    The consortium ENSA-Gas Natural Fenosa Engineering has a contract with Kozloduy Nuclear Power Plant (KNPP) for the retrieval and conditioning of the resins, which were generated during the operation of the plant. The project deals with resins characterization for which its necessary to define a proper methodology that fulfills the Bulgarian authorities requirements. Also, it will be included the design, fabrication, supply and installation of the required equipment to carry out the sampling and measurements of the resins, updating the facilities and the specific training of the personnel in order to perform by themselves every activities. This article reflects how the consortium will deal with the management of this damaging project, which involves a wide range of activities, including the management of each implicated are of both KNPP and external organizations. (Author)

  19. Solar power satellite rectenna design study: Directional receiving elements and parallel-series combining analysis

    Science.gov (United States)

    Gutmann, R. J.; Borrego, J. M.

    1978-01-01

    Rectenna conversion efficiencies (RF to dc) approximating 85 percent were demonstrated on a small scale, clearly indicating the feasibility and potential of efficiency of microwave power to dc. The overall cost estimates of the solar power satellite indicate that the baseline rectenna subsystem will be between 25 to 40 percent of the system cost. The directional receiving elements and element extensions were studied, along with power combining evaluation and evaluation extensions.

  20. Westinghouse experiences with HTR as the basis for design of the New Generation of Nuclear Power Plants (NGNP); Experiencias de Estinghouse con el HTR como Base para el diseno de la Nueva Generacion de Centrales Nucleares (BGNP)

    Energy Technology Data Exchange (ETDEWEB)

    Schoning, J.; Esch, M.; Knoche, D.; Freis, D.; Finken, H.; Drifhout, F.

    2010-07-01

    For more than three decades Germany had a very ambitious High Temperature Reactor (HTR) program which included numerous research activities and the construction and operation of two HTRs. The whole program had a volume of more than 6 billion D-Marks and covered activities of industry, research centres and universities. Within this program the physical feasibility of a pebble bed HTR was power for the first time in the Arbeitsgemeinschaft Versuchsreaktor (AVR) research reactor at Research Centre Julich (FZJ). Later it served as a test bed for new developed fuel as well as test reactor for numerous successful experiments on the inherent safety of this special type of nuclear reactor. The subsequent power plant THTR-300 with a rated electrical power of 300 MWel at Hamm-Uentrop was constructed as a demonstration plant. With THTR-300 the feasibility of a large commercial pebble bed reactor was demonstrated. Both reactors were built in the state of North-Rhine Westphalia with its traditional resources of coal and its heavy and chemical industry. HTRs were specifically meant to provide process heat to these industries and with the Project Nuclear Process Heat (PNP) a plant was developed to serve this means. Based on this HTR specific expertise and on actual experience from AP1000TM development and construction, Westinghouse has the overall expertise in house to design a generation IV reactor system in the near term future. On HTR specific systems and components the maturity of the technology was demonstrated with THTR-300. Potential design approaches for future HTR concepts for process heat generation are discussed. (Author) 1 refs.

  1. Internal event analysis of Laguna Verde Unit 1 Nuclear Power Plant. System Analysis; Analisis de Eventos Internos para la Unidad 1 de la Central Nucleoelectrica de Laguna Verde. Analisis de sistemas

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1993-07-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the {sup I}nternal Event Analysis of Laguna Verde Unit 1 Nuclear Power Plant{sup ,} CNSNS-TR-004, in five volumes. The reports are organized as follows: CNSNS-TR-004 Volume 1: Introduction and Methodology. CNSNS-TR-004 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR-004 Volume 3: System Analysis. CNSNS-TR-004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR-004 Volume 5: Appendices A, B and C. This volume presents the results of the system analysis for the Laguna Verde Unit 1 Nuclear Power Plant. The system analysis involved the development of logical models for all the systems included in the accident sequence event tree headings, and for all the support systems required to operate the front line systems. For the Internal Event analysis for Laguna Verde, 16 front line systems and 5 support systems were included. Detailed fault trees were developed for most of the important systems. Simplified fault trees focusing on major faults were constructed for those systems that can be adequately represent,ed using this kind of modeling. For those systems where fault tree models were not constructed, actual data were used to represent the dominant failures of the systems. The main failures included in the fault trees are hardware failures, test and maintenance unavailabilities, common cause failures, and human errors. The SETS and TEMAC codes were used to perform the qualitative and quantitative fault tree analyses. (Author)

  2. Earthquake-proof plants; Centrales a prueba de terremotos

    Energy Technology Data Exchange (ETDEWEB)

    Francescutti, P.

    2008-07-01

    In the wake of the damage suffered by the Kashiwazaki-Kariwa nuclear power plant as a result of an earthquake last July, this article looks at the seismic risk affecting the Spanish plants and the safety measures in place to prevent it. (Author)

  3. Modification and updating of documentation in equipment of panels of control room in nuclear power plant operation; Modificacion y actualizacion de documentacion en aparatos de paneles de sala de control en una central nuclear en operacion

    Energy Technology Data Exchange (ETDEWEB)

    Agudo Montero, L.

    2013-07-01

    The present paper describes a case very unique specific design of interactive 2D-CAD application, that has been developed by Empresarios Agrupados as engineering support to the nuclear power plants, aware of the problem that exists with the documentation of the instruments and devices that are on the panels of Control room, and that only have the documentation generated in its day by the manufacturers of these panels. To this end, an application (application DOPAB) has been developed to help solve the problem of management, design and modification of wiring and wiring devices existing in the Control room control panels.

  4. Settling and growth of D. polymorpha in the raw water circuits of the Cattenom nuclear power plant (Moselle, France); Fixation et croissance de D. Polymorpha dans les circuits d`eau brute de la centrale nucleaire de Cattenom

    Energy Technology Data Exchange (ETDEWEB)

    Moreteau, J.C.; Khalanski, M.

    1994-05-01

    A``biological profile`` of the zebra mussels which are infesting certain circuits of the Cattenom nuclear power plant has been provided by data collected during a three-year measurement programme (1991-1993). The larval settlement periods and the growth of settled mussels were monitored. A simple mathematical model, which calculates the shell growth on the long term, was calibrated with the field data. It is based on three functions representing the effect of the initial size, water temperature and fool availability (plankton chlorophyll a). (authors). 13 refs., 7 figs., 4 tabs.

  5. Transmission Reinforcements in the Central American Regional Power System

    Energy Technology Data Exchange (ETDEWEB)

    Elizondo, Marcelo A.; Vallem, Mallikarjuna R.; Samaan, Nader A.; Makarov, Yuri V.; Vyakaranam, Bharat; Nguyen, Tony B.; Munoz, Christian; Herrera, Ricardo; Midence, Diego; Shpitsberg, Anna

    2016-07-25

    The Central American regional interconnected power system (SER) connects the countries members of the Central American regional electricity market (MER): Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica, and Panama. The SER was a result of a long term regional effort, and was initially conceived to transfer 300 MW between countries. However, the current transfer limits between countries range from 70 MW to 300 MW. Regional entities, like CRIE (Regional Commission of Electrical Interconnection), EOR (Central American Regional System Operator), and CDMER (Board of Directors of the Central American Market) are working on coordinating the national transmission expansion plans with regional transmission planning efforts. This paper presents experience in Central America region to recommend transmission reinforcements to achieve 300 MW transfer capacity between any pair of member countries of the Central American regional electricity market (MER). This paper also provides a methodology for technical analysis and for coordination among the regional and national entities. This methodology is unique for transmission systems of these characteristics.

  6. Sensitivity Study of Atmospheric Attenuation in Tower Solar Power Plants with Radiative Trannsfer Models; Estudio de Sensibilidad de la Atenuacion Atmosferica en Centrales Termosolares de Torre con Modelos de Transferencia Radiativa

    Energy Technology Data Exchange (ETDEWEB)

    Carmero, A.; Polo, J.

    2014-02-01

    Nowadays, solar power tower technology is showing great development and it’s placed as one of the most solar resource exploitation. According to this, it’s necessary exhaustive analysis and studies in order to allow technological progress which gives more technical security and economical reliability with the current technologies. In response to technical development this project is focused on solar attenuation which it will be a large problem in large power tower plant all over the world. This document present the results of the postgraduate work addressed by the author and tutored by Jesús Polo in the Renewable Energy Division of Ciemat.The work was presented at Carlos III University of Madrid in July 2013. (Author)

  7. Retrofitting the small-scale hydro power plant 'La Chocolatiere' in Echandens-Bussigny, Switzerland; Rehabilitation de la petite centrale de la Chocolatiere (Echandens - Bussigny)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-05-15

    This report for the Swiss Federal Office of Energy (SFOE) is a project study for the retrofitting of a small-scale hydro power plant installed on the River Venoge, between the communities of Echandens and Bussigny, western Switzerland. At this site, hydro power is used since the 18{sup th} century. A permanent license to use at most 3 m{sup 3}/s is available. The study concludes that the maximum flow rate of 6 m{sup 3}/s would be more advantageous, implying a 35 cm higher dam on the river. Two turbines could then be installed, leading to the maximum electric power of 177 kW and the power production of 727,000 kWh/y. From the detailed inventory of the retrofitting work and the installation of the new turbines - including a new fish ladder according to the legislation in force - the authors conclude that electricity could be generated at a cost amounting to about CHF 0.24/kWh. It is recommended to request the modification of the water use license in order to be able to use up to 6 m{sup 3}/s.

  8. Risks of potential accidents of nuclear power plants in Europe

    NARCIS (Netherlands)

    Slaper H; Eggink GJ; Blaauboer RO

    1993-01-01

    Over 200 nuclear power plants for commercial electricity production are presently operational in Europe. The 1986 accident with the nuclear power plant in Chernobyl has shown that severe accidents with a nuclear power plant can lead to a large scale contamination of Europe. This report is focussed

  9. Risks of potential accidents of nuclear power plants in Europe

    NARCIS (Netherlands)

    Slaper H; Eggink GJ; Blaauboer RO

    1993-01-01

    Over 200 nuclear power plants for commercial electricity production are presently operational in Europe. The 1986 accident with the nuclear power plant in Chernobyl has shown that severe accidents with a nuclear power plant can lead to a large scale contamination of Europe. This report is focussed o

  10. 76 FR 66089 - Access Authorization Program for Nuclear Power Plants

    Science.gov (United States)

    2011-10-25

    ... COMMISSION Access Authorization Program for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission... revision to Regulatory Guide 5.66, ``Access Authorization Program for Nuclear Power Plants.'' This guide... Authorization Requirements for Nuclear Power Plants,'' and 10 CFR part 26, ``Fitness for Duty Programs.'' The......

  11. Goethermal power plant with Kalina cycle

    Energy Technology Data Exchange (ETDEWEB)

    Renz, M.; Filipovic, A. [M+W Zander Facility Engineering GmbH, Stuttgart (Germany). Marketing-Communications

    2005-04-01

    Several factors are creating an increased market for small power plant technology. These include the need for distributed/decentralised power systems, the need to generate more electricity by non-combustion renewable processes, the need for sustainable power for economic growth in developing countries and the deregulation and privatization of the electrical generation sector. Basically there are 2 alternate principles to improve the efficiency of the Rankine steam cycle for low temperature applications: Replacing water by a one-component fluid with lower boiling points, e.g. different organic substances like n-pentane, isobutene, perfluoropen-tane. (Organic Rankine Cycle, ORC). Replacing water by a binary working fluid like ammonia-water as proposed by Kalina. Kalina and ORC power cycles are primarily used for lower temperature heat sources, such as goethermal or waste-heat recovery. The primary advantage of this technology is the operation at low temperature which is given at renewable heat sources and waste heat. Further the power cycles are simple and generally can be operated remotely, without licensed operators, allowing for increased use of self-diagnostics. M+W Zander is working closely with partners to establish an alternative technology for geothermal applications. (orig.)

  12. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  13. China’s Nuclear Power Plants in Operation

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Qinshan Plant Phase I Located in Haiyan,Zhejiang Province,Qinshan Nuclear Power Plant Phase I is t he first 300-megawatt pressurized water reactor (PWR) nuclear power plant independently designed,constructed,operated and managed by China.The plant came into commercial operation in April 1994.

  14. Osmo-power - Theory and performance of an osmo-power pilot plant

    Science.gov (United States)

    Jellinek, H. H. G.; Masuda, H.

    A theoretical and experimental study of the production of useful energy by the natural process of osmosis is presented. Using the results of the study a conceptual design of an osmotic pilot plant is performed. The power produced by a 1.6 MW/sq km plant has a competitive cost with that produced by both fossil power plants and nuclear power plants.

  15. Water treatment plants assessment at Talkha power plant.

    Science.gov (United States)

    El-Sebaie, Olfat D; Abd El-Kerim, Ghazy E; Ramadan, Mohamed H; Abd El-Atey, Magda M; Taha, Sahr Ahmed

    2002-01-01

    Talkha power plant is the only power plant located in El-Mansoura. It generates electricity using two different methods by steam turbine and gas turbine. Both plants drew water from River Nile (208 m3 /h). The Nile raw water passes through different treatment processes to be suitable for drinking and operational uses. At Talkha power plant, there are two purification plants used for drinking water supply (100 m3/h) and for water demineralization supply (108 m3/h). This study aimed at studying the efficiency of the water purification plants. For drinking water purification plant, the annual River Nile water characterized by slightly alkaline pH (7.4-8), high annual mean values of turbidity (10.06 NTU), Standard Plate Count (SPC) (313.3 CFU/1 ml), total coliform (2717/100 ml), fecal coliform (0-2400/100 ml), and total algae (3 x 10(4) org/I). The dominant group of algae all over the study period was green algae. The blue green algae was abundant in Summer and Autumn seasons. The pH range, and the annual mean values of turbidity, TDS, total hardness, sulfates, chlorides, nitrates, nitrites, fluoride, and residual chlorine for purified water were in compliance with Egyptian drinking water standards. All the SPC recorded values with an annual mean value of 10.13 CFU/1 ml indicated that chlorine dose and contact time were not enough to kill the bacteria. However, they were in compliance with Egyptian decree (should not exceed 50 CFU/1 ml). Although the removal efficiency of the plant for total coliform and blue green algae was high (98.5% and 99.2%, respectively), the limits of the obtained results with an annual mean values of 40/100 ml and 15.6 org/l were not in compliance with the Egyptian decree (should be free from total coliform, fecal coliform and blue green algae). For water demineralization treatment plant, the raw water was characterized by slightly alkaline pH. The annual mean values of conductivity, turbidity, and TDS were 354.6 microS/cm, 10.84 NTU, and 214

  16. Pilot plant straw biomass power plant; Demonstrationsanlage Strohkraftwerk Gronau

    Energy Technology Data Exchange (ETDEWEB)

    Vodegel, Stefan [Claustahler Umwelttechnik-Institut GmbH (CUTEC), Clausthal-Zellerfeld (Germany); Lach, Friedrich-Wilhelm [Ueberlandwerk Leinetal GmbH, Gronau (Leine) (Germany)

    2008-07-01

    Drastically increasing prices for oil and gas promote the change to renewable energies. Biomass has the advantage of the storability. However, it has the disadvantage of a small stocking density. This suggests decentralized power plants. Also the proven technology of water vapour cycles with use of turbine is questioned. In the rural district Hildesheim there are efforts of thermal utilisation straw from wheat cropping. For this, a feasibility study of the Claustahler Umwelttechnik-Technik GmbH (Clausthal Zellerfeld, Federal Republic of Germany) presents technical and economic possibilities exemplary for the industrial area West in Gronau (Federal Republic of Germany). Technical and economic chances and risks are pointed out.

  17. Reduction of SO{sub 2} Emissions in coal power plants by means of spray-drying RESOX; Reduccion de Emisiones de SO{sub 2} en Centrales Termicas de Carbon Mediante Spary Drying

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    In this experimental study, two important matters concerning the spray-drying technology for the desulphurisation of combustion gases, from pulverized coal boilers, have been analyzed: (1) the behaviour of the spray-dryer absorber under different operating conditions and (2) the behaviour of an electrostatic precipitator that operates downstream from a spray-dryer. The results of this project are of great interest for evaluating the application of this semi-dry desulphurisation technology in existing power plants that already have electrostatic precipitators. Additionally, the conclusions drawn are useful for establishing the optimum design and operating conditions for an integrated SD-ESP flue gas treatment facility. More than 45 experimental tests have been conducted on a 10,000 Nm``3/h spray-drying desulphurisation pilot plant. The effects of SO{sub 2} and fly ash concentration, Ca/s ratio, approach to saturation temperature, density of the slurry and unit load changes on both spray dryer behaviour and treated flue gas properties have been analyzed. In two additional specific tests, the effect of injecting calcium chloride and of preparing the slurry with seawater has also been studied. The impact of spray-dryer desulphurization on the behaviour of the electrostatic precipitators has been evaluated comparing experimental data (Efficiency, emission level, electrical consumption) for the behaviour of the electrostatic precipitator, obtained in two different experimental conditions: with and without desulphurization. Additionally, the possibility of reducing the power consumption of the precipitator by means of intermittent energization has been analyzed. (Author)

  18. Reduction of SO{sub 2} Emissions in Coal Power Plants by means of Spray-Drying RESOX Research Project; Acondicionamiento de Gases de Combustion para la Reduccion de Emisiones de Particulas en Centrales Termicas de Carbon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    In this experimental study, two important matters concerning the spray-drying technology for the desulphurisation of combustion gases, from pulverized coal boilers, have been analyzed: (1) the behaviour of the spray-dryer absorber under different operating conditions and (2) the behaviour of an electrostatic precipitator that operates downstream form a spray-dryer. The results of this project are of great interest for evaluating the application of this semi-dry desulphurisation technology in existing power plants that already have electrostatic precipitators. Additionally, the conclusions drawn are useful for establishing the optimum design and operating conditions for an integrated SD-ESP flue gas treatment facility. More than 45 experimental tests have been conducted on a 10,000 Nm``3/h spray-drying desulphurisation pilot plant. The effects of SO{sub 2} and fly ash concentration, Ca/S ratio, approach to saturation temperature, density of the slurry and unit load changes on both spray dryer behaviour and treated flue gas properties have been analyzed. In two additional specific tests, the effect of injecting calcium chloride and of preparing the slurry with seawater has also been studied. The impact of spray-dryer desulphurization on the behaviour of the electrostatic precipitators ha been evaluated comparing experimental data (efficiency, emission level, electrical consumption) for the behaviour of the electrostatic precipitator, obtained in two different experimental conditions: with and without desulphurization. Additionally, the possibility of reducing the power consumption of the precipitator by means of intermittent energization has been analyzed. (Author)

  19. Progress and prospects for phosphoric acid fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bonville, L.J.; Scheffler, G.W.; Smith, M.J. [International Fuel Cells Corp., South Windsor, CT (United States)

    1996-12-31

    International Fuel Cells (IFC) has developed the fuel cell power plant as a new, on-site power generation source. IFC`s commercial fuel cell product is the 200-kW PC25{trademark} power plant. To date over 100 PC25 units have been manufactured. Fleet operating time is in excess of one million hours. Individual units of the initial power plant model, the PC25 A, have operated for more than 30,000 hours. The first model {open_quotes}C{close_quotes} power plant has over 10,000 hours of operation. The manufacturing, application and operation of this power plant fleet has established a firm base for design and technology development in terms of a clear understanding of the requirements for power plant reliability and durability. This fleet provides the benchmark against which power plant improvements must be measured.

  20. 75 FR 80547 - Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit No. 1; Exemption

    Science.gov (United States)

    2010-12-22

    ... COMMISSION Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit No. 1; Exemption 1.0... License No. NPF-63, which authorizes operation of the Shearon Harris Nuclear Power Plant (HNP), Unit 1... request to generically extend the rule's compliance date for all operating nuclear power plants, but...

  1. 75 FR 77919 - Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1; Environmental...

    Science.gov (United States)

    2010-12-14

    ... COMMISSION Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1; Environmental... Progress Energy Carolinas, Inc., for operation of the Shearon Harris Nuclear Power Plant (HNP), Unit 1...: Regarding Shearon Harris Nuclear Power Plant, Unit 1--Final Report (NUREG-1437, Supplement 33).''...

  2. 75 FR 9958 - Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit 1; Exemption

    Science.gov (United States)

    2010-03-04

    ... COMMISSION Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit 1; Exemption 1.0... of the Shearon Harris Nuclear Power Plant, Unit 1 (HNP). The license provides, among other things... operating nuclear power plants, but noted that the Commission's regulations provide mechanisms...

  3. Demand of natural uranium to satisfy the requirements of nuclear fuel of new nuclear power plants in Mexico; Demanda de uranio natural para satisfacer los requerimientos de combustible nuclear de nuevas centrales nucleares en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez S, J. R.; Rios, M. del C.; Alonso, G.; Palacios H, J. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jrrs@nuclear.inin.mx

    2008-07-01

    Due to the expectation of that in Mexico new plants of nuclear energy could be installed, turns out from the interest to evaluate the uranium requirements to operate those plants and to also evaluate if the existing reserves in the country could be sufficient to satisfy that demand. Three different scenes from nuclear power plant expansion for the country are postulated here that are desirable for the diversification of generation technologies. The first scene considers a growth in the generation by nuclear means of two reactors of type ABWR that could enter operation by years 2015 and 2020, in the second considers the installation of four reactors but as of 2015 and new every 5 years, in the scene of high growth considers the installation of 6 reactors of the same type that in the other scenes, settling one every three years as of 2015. The results indicate that the uranium reserves could be sufficient to only maintain in operation to one of the reactors proposed by the time of their useful life. (Author)

  4. El CAD en la actividad de reingeniería e ingeniería en los mantenimientos a centrales eléctricas // CAD in the reengineering and engineering activity in maintenance of power plants

    Directory of Open Access Journals (Sweden)

    R. García Ramírez

    2000-07-01

    Full Text Available El presente trabajo muestra algunas experiencias obtenidas en la actividad de ingeniería y reingeniería durante elmantenimiento a centrales eléctricas con empleo del CAD (Computer Aided Design, se muestran además las estrategiasseguidas con vistas a automatizar la actividad de reingeniería en ordenadores y a lograr mejoras económicas en la actividada costa de disminuir los costos de producción.Palabras claves: CAD, reingeniería, mantenimiento de calderas._________________________________________________________________________AbstractThe present work shows some experiences obtained in the engineering and reengineering during the maintenance activity inpower plants carried out by our company applying the CAD (Computer Aided Design, it is also exposed the strategyfollowed with a view to automating the reengineering activity with the use of computers, keeping in mind a view to achieveconomic improvements in the activity to diminish production costs.Key words: reengineering, CAD, maintenance, boiler.

  5. High-power LEDs for plant cultivation

    Science.gov (United States)

    Tamulaitis, Gintautas; Duchovskis, Pavelas; Bliznikas, Zenius; Breive, Kestutis; Ulinskaite, Raimonda; Brazaityte, Ausra; Novickovas, Algirdas; Zukauskas, Arturas; Shur, Michael S.

    2004-10-01

    We report on high-power solid-state lighting facility for cultivation of greenhouse vegetables and on the results of the study of control of photosynthetic activity and growth morphology of radish and lettuce imposed by variation of the spectral composition of illumination. Experimental lighting modules (useful area of 0.22 m2) were designed based on 4 types of high-power light-emitting diodes (LEDs) with emission peaked in red at the wavelengths of 660 nm and 640 nm (predominantly absorbed by chlorophyll a and b for photosynthesis, respectively), in blue at 455 nm (phototropic function), and in far-red at 735 nm (important for photomorphology). Morphological characteristics, chlorophyll and phytohormone concentrations in radish and lettuce grown in phytotron chambers under lighting with different spectral composition of the LED-based illuminator and under illumination by high pressure sodium lamps with an equivalent photosynthetic photon flux density were compared. A well-balanced solid-state lighting was found to enhance production of green mass and to ensure healthy morphogenesis of plants compared to those grown using conventional lighting. We observed that the plant morphology and concentrations of morphologically active phytohormones is strongly affected by the spectral composition of light in the red region. Commercial application of the LED-based illumination for large-scale plant cultivation is discussed. This technology is favorable from the point of view of energy consumption, controllable growth, and food safety but is hindered by high cost of the LEDs. Large scale manufacturing of high-power red AlInGaP-based LEDs emitting at 650 nm and a further decrease of the photon price for the LEDs emitting in the vicinity of the absorption peak of chlorophylls have to be achieved to promote horticulture applications.

  6. Modelling the power deposition into a spherical tokamak fusion power plant

    Science.gov (United States)

    Windsor, C. G.; Morgan, J. G.; Buxton, P. F.; Costley, A. E.; Smith, G. D. W.; Sykes, A.

    2017-03-01

    Numerical studies have been made to improve the performance of the central column of a superconducting spherical tokamak fusion pilot plant. The assumed neutron shield includes concentric layers of tungsten carbide and water. The relative thickness of the water layers was varied and a minimum power deposition was found at about 17% of water. It was found advantageous to have an approximately 1.7 times thicker water layer next to the core and a similarly thinner layer next to the plasma. The use of tungsten boride instead of tungsten carbide was shown to make an improvement especially if placed close to the central superconducting core, the inner layer alone reducing the power deposition by 29%. Engineering features such as a central steel tie-bar, an insulating thermal vacuum gap, a wall gap next to the plasma and knowledge of the vertical energy distribution are essential to a successful design and their effects on the power deposition are shown in an appendix. The results have been fitted to model distributions and incorporated into the Tokamak Energy System Code, which can then give predictions of the power deposition as a function of other parameters such as the plasma major radius and the maximum magnetic field permitted on the superconductors.

  7. Development of 3D models of buildings for containment of the nuclear power plant of Almaraz and of the Trillo Nuclear with the GOTHIC 8.0 code; Desarrollo de modelos 3D de los edificios de conten cion de la Central Nuclear de Almaraz y de la Central Nuclear de Trillo con el codigo GOTHIC 8.0

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, G.; Bocanegra Melian, R.; Fernandez Cosils, K.; Barreira Pereira, P.; Rey Peinado, L.; Posada Barral, J. M.

    2014-07-01

    The objective of the first phase of the research of CNAT and the UPM project is the construction of several three-dimensional models detailed GOTHIC 8.0 code of containment of a buildings plant type PWR-W and KWU, corresponding to the Central Nuclear de Almaraz (CNA) and Trillo (CNT) respectively. (Author)

  8. Exergoeconomic analysis of a nuclear power plant

    Science.gov (United States)

    Moreno, Roman Miguel

    Exergoeconomic analysis of a nuclear power plant is a focus of this dissertation. Specifically, the performance of the Palo Verde Nuclear Power Plant in Arizona is examined. The analysis combines thermodynamic second law exergy analysis with economics in order to assign costs to the loss and destruction of exergy. This work was done entirely with an interacting spreadsheets notebook. The procedures are to first determine conventional energy flow, where the thermodynamic stream state points are calculated automatically. Exergy flow is then evaluated along with destruction and losses. The capital cost and fixed investment rate used for the economics do not apply specifically to the Palo Verde Plant. Exergy costing is done next involving the solution of about 90 equations by matrix inversion. Finally, the analysis assigns cost to the exergy destruction and losses in each component. In this work, the cost of electricity (exergy), including capital cost, leaving the generator came to 38,400 /hr. The major exergy destruction occurs in the reactor where fission energy transfer is limited by the maxiμm permissible clad temperature. Exergy destruction costs were: reactor--18,207 hr, the low pressure turbine-2,000 /hr, the condenser--1,700 hr, the steam generator-1,200 $/hr. The inclusion of capital cost and O&M are important in new system design assessments. When investigating operational performance, however, these are sunk costs; only fuel cost needs to be considered. The application of a case study is included based on a real modification instituted at Palo Verde to reduce corrosion steam generator problems; the pressure in the steam generator was reduced from 1072 to 980 psi. Exergy destruction costs increased in the low pressure turbine and in the steam generator, but decreased in the reactor vessel and the condenser. The dissertation demonstrates the procedures and tools required for exergoeconomic analysis whether in the evaluation of a new nuclear reactor system

  9. The Applie d Research of Dual-effect Solid-adsorption Type Refrigeration Technology for Use in a Centralized Refrigeration System at a Thermal Power Plant%双效固体吸附制冷技术在热电厂集中 供冷中的应用研究

    Institute of Scientific and Technical Information of China (English)

    李中华; 王如竹

    2001-01-01

    采用双效固体吸附式制冷技术开发了热电厂新型集中供冷系 统。该系统结构简单、性能可靠、投资低、耗电少、无污染。不但可为全厂提供空调用冷, 而且可大幅度提高电厂机组热经济性,具有显著的节能与环保效果。%An innovative centralized refrigeration system was developed for a thermal power plant through the use of a dual-effect solid-adsorption type refrigeration te ch nology. The system features a simple structural design, reliable performance, lo w investment outlay, low power consumption and absence of pollutants. With the h elp of this system it is not only possible to supply cooling energy for the air - conditioning of the thermal power plant as a whole, but also greatly enhance the thermal efficiency of the power plant. Moreover, it also contributes to signifi cant energy savings and a pollution-free environment.

  10. Nuclear power plants for mobile applications

    Science.gov (United States)

    Anderson, J. L.

    1972-01-01

    Mobile nuclear powerplants for applications other than large ships and submarines will require compact, lightweight reactors with especially stringent impact-safety design. The technical and economic feasibility that the broadening role of civilian nuclear power, in general, (land-based nuclear electric generating plants and nuclear ships) can extend to lightweight, safe mobile nuclear powerplants are examined. The paper discusses technical experience, identifies potential sources of technology for advanced concepts, cites the results of economic studies of mobile nuclear powerplants, and surveys future technical capabilities needed by examining the current use and projected needs for vehicles, machines, and habitats that could effectively use mobile nuclear reactor powerplants.

  11. Conformation of an evaluation process for a license renovation solicitude of a nuclear power plant in Mexico; Conformacion de un proceso de evaluacion para una solicitud de renovacion de licencia de una central nuclear en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Serrano R, M. L., E-mail: mlserrano@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2012-10-15

    So that the construction stages, of operation, closing, dismantlement and the radioactive waste disposal of a nuclear power plant (NPP) are carried out in Mexico, is necessary that the operator has a license, permission or authorization for each stage. In Mexico, these licenses, permissions or authorizations are granted by the Energy Secretariat with base in the verdict of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The operation licenses ar the moment effective for the reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) they will expire respectively in the year 2020 and 2025 for the Unit 1 and Unit 2, for what the CNSNS has begun its preparation before a potential solicitude of the licensee to continue the operation of the NPP-L V. Defining the process to continue and to generate the documents that would help in this phase as normalization, guides, procedures, regulations, controls, etc., is the task that intends to be carried out the regulator body so that the evaluation process is effective and efficient, so much for the same regulator body as for the licensee. This work exposes the advance that the CNSNS has in this aspect and is centered specifically in the conformation of an evaluation process of license renovation solicitude, taking as base what the regulator body of the United States of North America (US NRC) established and following to the IAEA. Also, this work includes statistical of electric power production in Mexico, licensing antecedents for the NPP-L V, a world perspective of the license renovations and the regulation of the US NRC related to the license renovation of a NPP. (Author)

  12. 76 FR 4391 - Calvert Cliffs Nuclear Power Plant, LLC, Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-01-25

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC, Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2; Exemption 1.0 Background Calvert Cliffs Nuclear Power Plant, LLC, the licensee, is the holder of Facility Operating License Nos. DPR-53 and DPR-69 which authorizes operation of the Calvert Cliffs Nuclear...

  13. STARFIRE: a commercial tokamak fusion power plant study

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    STARFIRE is a 1200 MWe central station fusion electric power plant that utilizes a deuterium-tritium fueled tokamak reactor as a heat source. Emphasis has been placed on developing design features which will provide for simpler assembly and maintenance, and improved safety and environmental characteristics. The major features of STARFIRE include a steady-state operating mode based on continuous rf lower-hybrid current drive and auxiliary heating, solid tritium breeder material, pressurized water cooling, limiter/vacuum system for impurity control and exhaust, high tritium burnup and low vulnerable tritium inventories, superconducting EF coils outside the superconducting TF coils, fully remote maintenance, and a low-activation shield. A comprehensive conceptual design has been developed including reactor features, support facilities and a complete balance of plant. A construction schedule and cost estimate are presented, as well as study conclusions and recommendations.

  14. Hydrogen production by the solar-powered hybrid sulfur process: Analysis of the integration of the CSP and chemical plants in selected scenarios

    Science.gov (United States)

    Liberatore, Raffaele; Lanchi, Michela; Turchetti, Luca

    2016-05-01

    The Hybrid Sulfur (HyS) is a water splitting process for hydrogen production powered with high temperature nuclear heat and electric power; among the numerous thermo-chemical and thermo-electro-chemical cycles proposed in the literature, such cycle is considered to have a particularly high potential also if powered by renewable energy. SOL2HY2 (Solar to Hydrogen Hybrid Cycles) is a 3 year research project, co-funded by the Fuel Cells and Hydrogen Joint Undertaking (FCH JU). A significant part of the project activities are devoted to the analysis and optimization of the integration of the solar power plant with the chemical, hydrogen production plant. This work reports a part of the results obtained in such research activity. The analysis presented in this work builds on previous process simulations used to determine the energy requirements of the hydrogen production plant in terms of electric power, medium (550°C) temperature heat. For the supply of medium temperature (MT) heat, a parabolic trough CSP plant using molten salts as heat transfer and storage medium is considered. A central receiver CSP (Concentrated Solar Power) plant is considered to provide high temperature (HT) heat, which is only needed for sulfuric acid decomposition. Finally, electric power is provided by a power block included in the MT solar plant and/or drawn from the grid, depending on the scenario considered. In particular, the analysis presented here focuses on the medium temperature CSP plant, possibly combined with a power block. Different scenarios were analysed by considering plants with different combinations of geographical location and sizing criteria.

  15. An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants

    Directory of Open Access Journals (Sweden)

    Vijith Vijayakumaran Nair

    2015-06-01

    Full Text Available In near-field wireless-powered biomedical implants, the receiver voltage largely overrides the compliance of low-voltage power receiver systems. To limit the induced voltage, generally, low-voltage topologies utilize limiter circuits, voltage clippers or shunt regulators, which are power-inefficient methods. In order to overcome the voltage limitation and improve power efficiency, we propose an integrated chip high-voltage power receiver based on the step down approach. The topology accommodates voltages as high as 30 V and comprises a high-voltage semi-active rectifier, a voltage reference generator and a series regulator. Further, a battery management circuit that enables safe and reliable implant battery charging based on analog control is proposed and realized. The power receiver is fabricated in 0.35-μm high-voltage Bipolar-CMOS-DMOStechnology based on the LOCOS0.35-μm CMOS process. Measurement results indicate 83.5% power conversion efficiency for a rectifier at 2.1 mA load current. The low drop-out regulator based on the current buffer compensation and buffer impedance attenuation scheme operates with low quiescent current, reduces the power consumption and provides good stability. The topology also provides good power supply rejection, which is adequate for the design application. Measurement results indicate regulator output of 4 ± 0.03 V for input from 5 to 30 V and 10 ± 0.05 V output for input from 11 to 30 V with load current 0.01–100 mA. The charger circuit manages the charging of the Li-ion battery through all if the typical stages of the Li-ion battery charging profile.

  16. Verification of 3G and 4G Received Power Measurements in a Crowdsourcing Android App

    DEFF Research Database (Denmark)

    Lauridsen, Mads; Rodriguez, Ignacio; Mikkelsen, Lars Møller

    2016-01-01

    Many crowdsourcing Android applications are available for measuring network Key Performance Indicators such as received power, latency, and throughput. The data is useful for end-users, researchers, and Mobile Network Operators, but unfortunately the applications’ accuracy are rarely verified....... In this paper we verify the crowdsourcing Android application NetMap’s ability to measure LTE Reference Signal Received Power by analyzing the Root Mean Squared Error, being 2-3 dB, and cross-correlation coefficient, being above 0.8, with measurements obtained by use of a professional radio network scanner...

  17. Waehlitz industrial power plant. Final report; Industriekraftwerk Waehlitz. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, M.; Winkler, F.; Becher, J.

    1997-05-01

    Combustion of high-sulphur lignite from the Central German mining area in an industrial power plant (combined heat and power) with a thermal capacity of 119 MW within the emission limits of the Technical Clean Air Directive (TA-Luft) and the 13th Federal Emissions Regulation (13. BImSchV). In addition to the legally required CO, SO{sub 2}, NO{sub x} and dust measurements, measuring equipment for continuous recording of N{sub 2}O under operating conditions has been installed. (orig.) [Deutsch] Verwertung schwefelreicher Braunkohle aus dem mitteldeutschen Bergbaurevier in einem Industriekraftwerk (Kraft-Waerme-Kopplung) mit einer thermischen Leistung von 119 MW unter den Bedingungen der Einhaltung der Forderungen der TA-Luft und der 13. BImSchV. Ausser den gesetzlich vorgeschriebenen Emissionsmessungen fuer CO, SO{sub 2}, NO{sub x}, Staub wurde eine Messstelle fuer einen kontinuierlichen Nachweis von N{sub 2}O unter Betriebsbedingungen installiert. (orig.)

  18. Power plant instrumentation and control handbook a guide to thermal power plants

    CERN Document Server

    Basu, Swapan

    2014-01-01

    The book discusses instrumentation and control in modern fossil fuel power plants, with an emphasis on selecting the most appropriate systems subject to constraints engineers have for their projects. It provides all the plant process and design details, including specification sheets and standards currently followed in the plant. Among the unique features of the book are the inclusion of control loop strategies and BMS/FSSS step by step logic, coverage of analytical instruments and technologies for pollution and energy savings, and coverage of the trends toward filed bus systems and integratio

  19. 核电站数字化反应堆保护系统中央处理器负荷率分析与测试%Analysis and Test of Nuclear Power Plant Reactor Trip Protect System Central Processing Unit Load Function Test

    Institute of Scientific and Technical Information of China (English)

    汪绩宁

    2013-01-01

    There are exact demands about the Central Processing Unit(CPU) load of nuclear power plant reactor trip protect system. This paper first theoretically analyzed the Central Processing Unit(CPU) load of nuclear power plant reactor trip protect system, gave the computational methods, then designed the test method and test equipment. And the real test work was also carried out. The test result is obtained by analyzing the experimental data. The result shows that reactor trip protect system of the Central Processing Unit(CPU) load of nuclear power plant accords with the techno-requirement, and the load of main-control-CPU is higher than the load of standby-CPU.%核电站对数字化反应堆保护系统的中央处理器的负荷率有严格要求。本文首先对核电站数字化反应堆保护系统中央处理器的负荷率进行了理论分析,得出了负荷率计算公式;然后设计了相应的负荷率测试方法与测试装置,完成了实际的测试工作;对测试所得实验数据进行处理,得出测试结果,结果表明数字化反应堆保护系统的中央处理器负荷率符合技术要求,且主控CPU的负荷率比备用CPU负荷率要高。

  20. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan; K. Coleman

    2002-10-15

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), 35 MPa (5000 psi) steam. In the 21st century, the world faces the critical challenge of providing abundant, cheap electricity to meet the needs of a growing global population while at the same time preserving environmental values. Most studies of this issue conclude that a robust portfolio of generation technologies and fuels should be developed to assure that the United States will have adequate electricity supplies in a variety of possible future scenarios. The use of coal for electricity generation poses a unique set of challenges. On the one hand, coal is plentiful and available at low cost in much of the world, notably in the U.S., China, and India. Countries with large coal reserves will want to develop them to foster economic growth and energy security. On the other hand, traditional methods of coal combustion emit pollutants and CO{sub 2} at high levels relative to other generation options. Maintaining coal as a generation option in the 21st century will require methods for addressing these environmental issues. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop of advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced materials that will make it possible to