WorldWideScience

Sample records for central line placement

  1. Abduction of Arm Facilitates Correction of Kinked Peel-Away Sheath During Subclavian Central Line Placement.

    Science.gov (United States)

    Kim, Sunghoon

    2015-12-01

    A tunneled central line catheter placement using a subclavian vein approach can be complicated by an occurrence of peel-away sheath kink which prevents the advancement of the catheter through the sheath. The kink is created due to the angular junction of subclavian and brachiocephalic veins which meet at 90 degree angle. A technique is described which corrects the peel-away sheath kink by extending the subclavian/brachiocephalic vein angle to greater than 90 degrees by abducting the patient's arm. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  3. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  4. Using real-time problem solving to eliminate central line infections.

    Science.gov (United States)

    Shannon, Richard P; Frndak, Diane; Grunden, Naida; Lloyd, Jon C; Herbert, Cheryl; Patel, Bhavin; Cummins, Daniel; Shannon, Alexander H; O'Neill, Paul H; Spear, Steven J

    2006-09-01

    An estimated 200,000 Americans suffer central line-associated bloodstream infections (CLABs) each year, with 15%-20% mortality. Two intensive care units (ICUs) redefined the processes of care through system redesign to deliver reliable outcomes free of the variations that created the breeding ground for infection. The ICUs, comprising 28 beds at Allegheny General Hospital, employed the principles of the Toyota Production System adapted to health care--Perfecting Patient Care--and applied them to central line placement and maintenance. Intensive observations, which revealed multiple variances from established practices, and root cause analyses of all CLABs empowered the workers to implement countermeasures designed to eliminate the defects in the processes of central line placement and maintenance. New processes were implemented within 90 days. Within a year CLABs decreased from 49 to 6 (10.5 to 1.2 infections/1,000 line-days), and mortalities from 19 to 1 (51% to 16%), despite an increase in the use of central lines and number of line-days. These results were sustained during a 34-month period. CLABs are not an inevitable product of complex ICU care but the result of highly variable and therefore unreliable care delivery that predisposes to infection.

  5. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  6. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  7. Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?

    Science.gov (United States)

    Martyak, Michael; Kabir, Ishraq; Britt, Rebecca

    2017-08-01

    Peripherally inserted central venous catheters (PICCs) are now commonly used for central access in the intensive care unit (ICU) setting; however, there is a paucity of data evaluating the complication rates associated with these lines. We performed a retrospective review of all PICCs placed in the inpatient setting at our institution during a 1-year period from January 2013 to December 2013. These were divided into two groups: those placed at the bedside in the ICU and those placed by interventional radiology in non-ICU patients. Data regarding infectious and thrombotic complications were collected and evaluated. During the study period, 1209 PICC line placements met inclusion criteria and were evaluated; 1038 were placed by interventional radiology in non-ICU patients, and 171 were placed at the bedside in ICU patients. The combined thrombotic and central line associated blood stream infection rate was 6.17 per cent in the non-ICU group and 10.53 per cent in the ICU group (P = 0.035). The thrombotic complication rate was 5.88 per cent in the non-ICU group and 7.60 per cent in the ICU group (P = 0.38), whereas the central line associated blood stream infection rate was 0.29 per cent in the non-ICU group and 2.92 per cent in the ICU group (P = 0.002). This study seems to suggest that PICC lines placed at the bedside in the ICU setting are associated with higher complication rates, in particular infectious complications, than those placed by interventional radiology in non-ICU patients. The routine placement of PICC lines in the ICU settings needs to be reevaluated given these findings.

  8. Can a virtual reality assessment of fine motor skill predict successful central line insertion?

    Science.gov (United States)

    Mohamadipanah, Hossein; Parthiban, Chembian; Nathwani, Jay; Rutherford, Drew; DiMarco, Shannon; Pugh, Carla

    2016-10-01

    Due to the increased use of peripherally inserted central catheter lines, central lines are not performed as frequently. The aim of this study is to evaluate whether a virtual reality (VR)-based assessment of fine motor skills can be used as a valid and objective assessment of central line skills. Surgical residents (N = 43) from 7 general surgery programs performed a subclavian central line in a simulated setting. Then, they participated in a force discrimination task in a VR environment. Hand movements from the subclavian central line simulation were tracked by electromagnetic sensors. Gross movements as monitored by the electromagnetic sensors were compared with the fine motor metrics calculated from the force discrimination tasks in the VR environment. Long periods of inactivity (idle time) during needle insertion and lack of smooth movements, as detected by the electromagnetic sensors, showed a significant correlation with poor force discrimination in the VR environment. Also, long periods of needle insertion time correlated to the poor performance in force discrimination in the VR environment. This study shows that force discrimination in a defined VR environment correlates to needle insertion time, idle time, and hand smoothness when performing subclavian central line placement. Fine motor force discrimination may serve as a valid and objective assessment of the skills required for successful needle insertion when placing central lines. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices

  10. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  11. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  12. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series.

    Science.gov (United States)

    Docktor, B L; Sadler, D J; Gray, R R; Saliken, J C; So, C B

    1999-08-01

    The objective was to examine the success and immediate complication rates in a large series of radiologically placed tunneled central venous catheters. We prospectively recorded the success and immediate complication rates in 880 consecutive radiologically placed tunneled central venous catheters. We also recorded the indication for placement, the success of placement, the number of passes required, and whether a double- or single-wall puncture occurred. Hemodialysis was the most common indication for long-term venous access. Venous access was successful in all patients, and catheter placement was successful in 99.4% of patients, with only five failed placements. All patients in whom placement was initially unsuccessful underwent successful placement the same day. All catheters were placed using real-time sonographic guidance. Most were placed in an internal jugular vein, with 87.4% requiring only a single needle pass. The immediate complication rate was only 4.0%, and no major complications occurred. To our knowledge, this series is the largest for which the immediate complication and success rates for radiologically placed central venous catheters have been reported. Our results suggest that radiologic placement of tunneled central venous catheters is a safe and effective alternative to surgery.

  13. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  14. Serious Gaming to Improve the Safety of Central Venous Catheter Placement

    Directory of Open Access Journals (Sweden)

    Daniel Katz

    2013-06-01

    Full Text Available Approximately 5 million central venous catheters (CVCs are placed by physicians annually in the United States, with a complication rate of 15%.1 Guidelines and recommendations are continually being established and updated regarding CVC placement.2 While much has been done regarding training the technical skills of CVC placement using part-task trainers (i.e., mannequins, successfully finding and cannulating a central vein is but one part of the process. In fact, many steps designed to prevent untoward complications involve non-technical skills which are perhaps more important in training practitioners to safely place CVCs. First in aviation and now in healthcare, practitioners are being trained in realistic and highly interactive simulated environments so they can learn not just technical skills , but the key management and non-technical steps which make their task safer.3 One modality being used to improve performance is video gaming simulation, or "serious gaming." Gaming as a learning tool is being increasingly utilized in health care fields and can lead to better skill-based outcomes.4 As such, we have developed a game based around the placement of CVCs that will be used as a new teaching modality in a pilot program for instructing residents in safe CVC placement.

  15. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  16. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  17. Treatment of malignant central airway obstruction with Y-type metallic stent placement under general anaesthesia

    International Nuclear Information System (INIS)

    Yang Zhengqiang; Shi Haibin; Zhou Weizhong; Leng Derong; Li Linsun

    2010-01-01

    Objective: To report the clinical experience in treating malignant central airway obstruction with the placement of a domestic Y-shaped stent under general anaesthesia. Methods: The placement of a domestic Y-stent under general anaesthesia together with tracheal intubation was performed in three male patients of central lung cancer with the involvement of carina and subsequent malignant airway stenosis. The combination of Y-stent delivering and tracheal intubation had not been reported in the literature so far, so the technical experience was introduced in this paper. Results: The placement of Y-stent was successfully completed in all 3 patients. The whole procedure was smoothly carried out with no severe complications. After the operation the dyspnea was markedly relieved in all the patients. Conclusion: As a safe and effective treatment for malignant central airway obstructions, the placement of a domestic Y-stent under general anaesthesia can reduce patient's discomfort during the stent delivering process. A large cohort of patients is required in order to evaluate the long-term efficacy and related complications of this technique. (authors)

  18. Sensor Placement For Structural Monitoring of Transmission Line Towers

    Directory of Open Access Journals (Sweden)

    Benny eRaphael

    2015-11-01

    Full Text Available Transmission line towers are usually analyzed using linear elastic idealized truss models. Due to the assumptions used in the analysis, there are discrepancies between the actual results obtained from full scale prototype testing and the analytical results. Therefore, design engineers are interested in assessing the actual stress levels in transmission line towers. Since it is costly to place sensors on every member of a tower structure, the best locations for sensors need to be carefully selected. This study evaluates a methodology for sensor placement in transmission line towers. The objective is to find optimal locations for sensors such that the real behavior of the structure can be explained from measurements. The methodology is based on the concepts of entropy and model falsification. Sensor locations are selected based on maximum entropy such that there is maximum separation between model instances that represent different possible combinations of parameter values which have uncertainties. The performance of the proposed algorithm is compared to that of an intuitive method in which sensor locations are selected where the forces are maximum. A typical 220 kV transmission tower is taken as case study in this paper. It is shown that the intuitive method results in much higher number of non-separable models compared to the optimal sensor placement algorithm. Thus the intuitive method results in poor identification of the system.

  19. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  20. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  1. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  2. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  3. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  4. D Central Line Extraction of Fossil Oyster Shells

    Science.gov (United States)

    Djuricic, A.; Puttonen, E.; Harzhauser, M.; Mandic, O.; Székely, B.; Pfeifer, N.

    2016-06-01

    Photogrammetry provides a powerful tool to digitally document protected, inaccessible, and rare fossils. This saves manpower in relation to current documentation practice and makes the fragile specimens more available for paleontological analysis and public education. In this study, high resolution orthophoto (0.5 mm) and digital surface models (1 mm) are used to define fossil boundaries that are then used as an input to automatically extract fossil length information via central lines. In general, central lines are widely used in geosciences as they ease observation, monitoring and evaluation of object dimensions. Here, the 3D central lines are used in a novel paleontological context to study fossilized oyster shells with photogrammetric and LiDAR-obtained 3D point cloud data. 3D central lines of 1121 Crassostrea gryphoides oysters of various shapes and sizes were computed in the study. Central line calculation included: i) Delaunay triangulation between the fossil shell boundary points and formation of the Voronoi diagram; ii) extraction of Voronoi vertices and construction of a connected graph tree from them; iii) reduction of the graph to the longest possible central line via Dijkstra's algorithm; iv) extension of longest central line to the shell boundary and smoothing by an adjustment of cubic spline curve; and v) integration of the central line into the corresponding 3D point cloud. The resulting longest path estimate for the 3D central line is a size parameter that can be applied in oyster shell age determination both in paleontological and biological applications. Our investigation evaluates ability and performance of the central line method to measure shell sizes accurately by comparing automatically extracted central lines with manually collected reference data used in paleontological analysis. Our results show that the automatically obtained central line length overestimated the manually collected reference by 1.5% in the test set, which is deemed

  5. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  6. 3D CENTRAL LINE EXTRACTION OF FOSSIL OYSTER SHELLS

    Directory of Open Access Journals (Sweden)

    A. Djuricic

    2016-06-01

    Full Text Available Photogrammetry provides a powerful tool to digitally document protected, inaccessible, and rare fossils. This saves manpower in relation to current documentation practice and makes the fragile specimens more available for paleontological analysis and public education. In this study, high resolution orthophoto (0.5 mm and digital surface models (1 mm are used to define fossil boundaries that are then used as an input to automatically extract fossil length information via central lines. In general, central lines are widely used in geosciences as they ease observation, monitoring and evaluation of object dimensions. Here, the 3D central lines are used in a novel paleontological context to study fossilized oyster shells with photogrammetric and LiDAR-obtained 3D point cloud data. 3D central lines of 1121 Crassostrea gryphoides oysters of various shapes and sizes were computed in the study. Central line calculation included: i Delaunay triangulation between the fossil shell boundary points and formation of the Voronoi diagram; ii extraction of Voronoi vertices and construction of a connected graph tree from them; iii reduction of the graph to the longest possible central line via Dijkstra’s algorithm; iv extension of longest central line to the shell boundary and smoothing by an adjustment of cubic spline curve; and v integration of the central line into the corresponding 3D point cloud. The resulting longest path estimate for the 3D central line is a size parameter that can be applied in oyster shell age determination both in paleontological and biological applications. Our investigation evaluates ability and performance of the central line method to measure shell sizes accurately by comparing automatically extracted central lines with manually collected reference data used in paleontological analysis. Our results show that the automatically obtained central line length overestimated the manually collected reference by 1.5% in the test set, which

  7. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Butler, Philip J.; Sood, Shreya; Mojibian, Hamid; Tal, Michael G.

    2011-01-01

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History of PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71–3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.

  8. Central Line Associated Blood Stream Infection Rate after ...

    African Journals Online (AJOL)

    find out the CLABSI rate before and after central line (CL) bundle intervention and compare the outcome with international surveillance ... was reduced from 10.1 to 6.5 per 1000 CL days after interventions and had significant correlation with overall bundle ..... Sales AE, Almenoff PL, et al. Reduction of central line infections ...

  9. The use of augmented reality glasses in central line simulation: "see one, simulate many, do one competently, and teach everyone".

    Science.gov (United States)

    Huang, Cynthia Y; Thomas, Jonathan B; Alismail, Abdullah; Cohen, Avi; Almutairi, Waleed; Daher, Noha S; Terry, Michael H; Tan, Laren D

    2018-01-01

    The aim of this study was to investigate the feasibility of using augmented reality (AR) glasses in central line simulation by novice operators and compare its efficacy to standard central line simulation/teaching. This was a prospective randomized controlled study enrolling 32 novice operators. Subjects were randomized on a 1:1 basis to either simulation using the augmented virtual reality glasses or simulation using conventional instruction. The study was conducted in tertiary-care urban teaching hospital. A total of 32 adult novice central line operators with no visual or auditory impairments were enrolled. Medical doctors, respiratory therapists, and sleep technicians were recruited from the medical field. The mean time for AR placement in the AR group was 71±43 s, and the time to internal jugular (IJ) cannulation was 316±112 s. There was no significant difference in median (minimum, maximum) time (seconds) to IJ cannulation for those who were in the AR group and those who were not (339 [130, 550] vs 287 [35, 475], p =0.09), respectively. There was also no significant difference between the two groups in median total procedure time (524 [329, 792] vs 469 [198, 781], p =0.29), respectively. There was a significant difference in the adherence level between the two groups favoring the AR group ( p =0.003). AR simulation of central venous catheters in manikins is feasible and efficacious in novice operators as an educational tool. Future studies are recommended in this area as it is a promising area of medical education.

  10. Association between central papilla recession and gingival and interdental smile line.

    Science.gov (United States)

    Kolte, Abhay P; Kolte, Rajashri A; Agrawal, Anshuka A; Shrirao, Tushar; Mankar, Kamal

    2017-11-30

    Interdental soft tissues play a critical role in pink esthetics. The presence and preservation of the interdental papillae in the esthetic zone is as crucial as the shape and contour of the anterior teeth in achieving an esthetically pleasing smile. The present study determines the association of central papilla recession with gingival and interdental smile line in periodontally healthy patients of different age groups. The present study included 200 patients equally divided into 21 to 40 years and 41 to 60 years age groups. The clinical and photographic evaluation of the central papilla, with midfacial gingiva, and its relationship with the vermilion border was performed. In total, 137 patients exhibited presence of central papilla, whilst 63 patients had central papilla recession with variable extent. The male patients predominantly had presence of central papilla in both the age groups, with 86% and 64%, compared with 74% and 50% in females, respectively. High gingival smile line was seen in the majority of the patients (62%), and this trend was similar to high interdental smile line (82% of the patients). Esthetics is affected in individuals having papilla recession along with high gingival smile line and interdental smile line as compared to individuals with low or cupid bow gingival smile line and interdental smile line.

  11. The use of augmented reality glasses in central line simulation: “see one, simulate many, do one competently, and teach everyone”

    Science.gov (United States)

    Huang, Cynthia Y; Thomas, Jonathan B; Alismail, Abdullah; Cohen, Avi; Almutairi, Waleed; Daher, Noha S; Terry, Michael H; Tan, Laren D

    2018-01-01

    Objective The aim of this study was to investigate the feasibility of using augmented reality (AR) glasses in central line simulation by novice operators and compare its efficacy to standard central line simulation/teaching. Design This was a prospective randomized controlled study enrolling 32 novice operators. Subjects were randomized on a 1:1 basis to either simulation using the augmented virtual reality glasses or simulation using conventional instruction. Setting The study was conducted in tertiary-care urban teaching hospital. Subjects A total of 32 adult novice central line operators with no visual or auditory impairments were enrolled. Medical doctors, respiratory therapists, and sleep technicians were recruited from the medical field. Measurements and main results The mean time for AR placement in the AR group was 71±43 s, and the time to internal jugular (IJ) cannulation was 316±112 s. There was no significant difference in median (minimum, maximum) time (seconds) to IJ cannulation for those who were in the AR group and those who were not (339 [130, 550] vs 287 [35, 475], p=0.09), respectively. There was also no significant difference between the two groups in median total procedure time (524 [329, 792] vs 469 [198, 781], p=0.29), respectively. There was a significant difference in the adherence level between the two groups favoring the AR group (p=0.003). Conclusion AR simulation of central venous catheters in manikins is feasible and efficacious in novice operators as an educational tool. Future studies are recommended in this area as it is a promising area of medical education. PMID:29785148

  12. Product Placement in Cartoons

    Directory of Open Access Journals (Sweden)

    Irena Oroz Štancl

    2014-06-01

    Full Text Available Product placement is a marketing approach for integrating products or services into selected media content. Studies have shown that the impact of advertising on children and youth are large, and that it can affect their preferences and attitudes. The aim of this article is to determine the existing level of product placement in cartoons that are broadcast on Croatian television stations. Content analysis of cartoons in a period of one month gave the following results: in 30% of cartoons product placement was found; most product placement were visual ads, in 89%, however, auditory product placement and plot connection was also found. Most ads were related to toys and it is significant that even 65% of cartoons are accompanied by a large amount of products available on the Croatian market. This is the result of two sales strategies: brand licensing (selling popular cartoon characters to toys, food or clothing companies and cartoon production based on existing line of toys with the sole aim of making their sales more effective.

  13. Monitoring the monitors: tubes and lines on chest radiographs

    International Nuclear Information System (INIS)

    Wunderbaldinger, P. . patrick.wunderbaldinger@univie.ac.at

    2001-01-01

    Chest radiography is essential to evaluate the placement and position of tubes and lines in patients treated in intensive care units, such as central venous and arterial catheters, endotracheal and nasogastric tubes, thorax drains, cardiac pacemakers and defibrillators. Radiologic findings with respect to normal positioning, wrong positioning, and complications are described and illustrated. (author)

  14. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of

  15. 49 CFR 71.5 - Boundary line between eastern and central zones.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Boundary line between eastern and central zones... BOUNDARIES § 71.5 Boundary line between eastern and central zones. (a) Minnesota-Michigan-Wisconsin. From the junction of the western boundary of the State of Michigan with the boundary between the United States and...

  16. APSIC guide for prevention of Central Line Associated Bloodstream Infections (CLABSI

    Directory of Open Access Journals (Sweden)

    Moi Lin Ling

    2016-05-01

    Full Text Available Abstract This document is an executive summary of the APSIC Guide for Prevention of Central Line Associated Bloodstream Infections (CLABSI. It describes key evidence-based care components of the Central Line Insertion and Maintenance Bundles and its implementation using the quality improvement methodology, namely the Plan-Do-Study-Act (PDSA methodology involving multidisciplinary process and stakeholders. Monitoring of improvement over time with timely feedback to stakeholders is a key component to ensure the success of implementing best practices. A surveillance program is recommended to monitor outcomes and adherence to evidence-based central line insertion and maintenance practices (compliance rate and identify quality improvement opportunities and strategically targeting interventions for the reduction of CLABSI.

  17. Derivative load voltage and particle swarm optimization to determine optimum sizing and placement of shunt capacitor in improving line losses

    Directory of Open Access Journals (Sweden)

    Mohamed Milad Baiek

    2016-12-01

    Full Text Available The purpose of this research is to study optimal size and placement of shunt capacitor in order to minimize line loss. Derivative load bus voltage was calculated to determine the sensitive load buses which further being optimum with the placement of shunt capacitor. Particle swarm optimization (PSO was demonstrated on the IEEE 14 bus power system to find optimum size of shunt capacitor in reducing line loss. The objective function was applied to determine the proper placement of capacitor and get satisfied solutions towards constraints. The simulation was run over Matlab under two scenarios namely base case and increasing 100% load. Derivative load bus voltage was simulated to determine the most sensitive load bus. PSO was carried out to determine the optimum sizing of shunt capacitor at the most sensitive bus. The results have been determined that the most sensitive bus was bus number 14 for the base case and increasing 100% load. The optimum sizing was 8.17 Mvar for the base case and 23.98 Mvar for increasing load about 100%. Line losses were able to reduce approximately 0.98% for the base case and increasing 100% load reduced about 3.16%. The proposed method was also proven as a better result compared with harmony search algorithm (HSA method. HSA method recorded loss reduction ratio about 0.44% for the base case and 2.67% when the load was increased by 100% while PSO calculated loss reduction ratio about 1.12% and 4.02% for the base case and increasing 100% load respectively. The result of this study will support the previous study and it is concluded that PSO was successfully able to solve some engineering problems as well as to find a solution in determining shunt capacitor sizing on the power system simply and accurately compared with other evolutionary optimization methods.

  18. Sustained reduction of central line-associated bloodstream infections outside the intensive care unit with a multimodal intervention focusing on central line maintenance.

    Science.gov (United States)

    Dumyati, Ghinwa; Concannon, Cathleen; van Wijngaarden, Edwin; Love, Tanzy M T; Graman, Paul; Pettis, Ann Marie; Greene, Linda; El-Daher, Nayef; Farnsworth, Donna; Quinlan, Gail; Karr, Gloria; Ward, Lynnette; Knab, Robin; Shelly, Mark

    2014-07-01

    Central venous catheter use is common outside the intensive care units (ICUs), but prevention in this setting is not well studied. We initiated surveillance for central line-associated bloodstream infections (CLABSIs) outside the ICU setting and studied the impact of a multimodal intervention on the incidence of CLABSIs across multiple hospitals. This project was constructed as a prospective preintervention-postintervention design. The project comprised 3 phases (preintervention [baseline], intervention, and postintervention) over a 4.5-year period (2008-2012) and was implemented through a collaborative of 37 adult non-ICU wards at 6 hospitals in the Rochester, NY area. The intervention focused on engagement of nursing staff and leadership, nursing education on line care maintenance, competence evaluation, audits of line care, and regular feedback on CLABSI rates. Quarterly rates were compared over time in relation to intervention implementation. The overall CLABSI rate for all participating units decreased from 2.6/1000 line-days preintervention to 2.1/1,000 line-days during the intervention and to 1.3/1,000 line-days postintervention, a 50% reduction (95% confidence interval, .40-.59) compared with the preintervention period (P .0179). A multipronged approach blending both the adaptive and technical aspects of care including front line engagement, education, execution of best practices, and evaluation of both process and outcome measures may provide an effective strategy for reducing CLABSI rates outside the ICU. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  19. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    Science.gov (United States)

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. The use of augmented reality glasses in central line simulation: "see one, simulate many, do one competently, and teach everyone"

    Directory of Open Access Journals (Sweden)

    Huang CY

    2018-05-01

    Full Text Available Cynthia Y Huang,1 Jonathan B Thomas,2 Abdullah Alismail,3 Avi Cohen,1 Waleed Almutairi,3 Noha S Daher,4 Michael H Terry,5 Laren D Tan1,3 1Department of Medicine, Division of Pulmonary, Critical Care, Hyperbaric and Sleep Medicine, Loma Linda University, Loma Linda, CA, USA; 2Zapara School of Business, La Sierra University, Riverside, CA, USA; 3Cardiopulmonary Sciences Department, School of Allied Health Professions, Loma Linda University, Loma Linda, CA, USA; 4Department of Allied Health Studies, School of Allied Health Professions, Loma Linda University, Loma Linda, CA, USA; 5Department of Respiratory Care, Loma Linda University Medical Center, Loma Linda, CA, USA Objective: The aim of this study was to investigate the feasibility of using augmented reality (AR glasses in central line simulation by novice operators and compare its efficacy to standard central line simulation/teaching. Design: This was a prospective randomized controlled study enrolling 32 novice operators. Subjects were randomized on a 1:1 basis to either simulation using the augmented virtual reality glasses or simulation using conventional instruction. Setting: The study was conducted in tertiary-care urban teaching hospital. Subjects: A total of 32 adult novice central line operators with no visual or auditory impairments were enrolled. Medical doctors, respiratory therapists, and sleep technicians were recruited from the medical field. Measurements and main results: The mean time for AR placement in the AR group was 71±43 s, and the time to internal jugular (IJ cannulation was 316±112 s. There was no significant difference in median (minimum, maximum time (seconds to IJ cannulation for those who were in the AR group and those who were not (339 [130, 550] vs 287 [35, 475], p=0.09, respectively. There was also no significant difference between the two groups in median total procedure time (524 [329, 792] vs 469 [198, 781], p=0.29, respectively. There was a significant

  1. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  2. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  3. Central line associated sepsis in children receiving parenteral nutrition in Oman.

    Science.gov (United States)

    Al Lawati, Tawfiq T; Al Jamie, Adawaiya; Al Mufarraji, Nasra

    Parenteral Nutrition (PN) is used when gut fails to provide complete nutrition. Central line Associate Blood Stream Infection (CLABSI) a major complication of this therapy. The objective of the study was to report the incidence of CLABSI and associated mortality in children receiving PN in the Royal Hospital and study the indication and duration of PN use. All children from the age of 0-48 months who received TPN outside NICU from the period between 1/1/2011 till 31/12/2014 were included. Data were retrieved from the hospital electronic data base. There were 42 children 27 males and 15 females who used PN through a central line for a total duration of 569 days. The incidence of CLABSI was 14 days per 1000 days catheter and mortality of 556 per 10000. The average duration of TPN was 14.5 days. Most of the patient had CLABSI in the PICU and cardiac related illness or surgery was the most common indication of PN use. The average duration of use was 14 days. Inspite of that short duration use of PN, there is a very high incidence of CLABSI and its related mortality. Bundle policy for central line care is not used in the Royal Hospital and this study calls for urgent implementation of central line care bundle policy in the Royal Hospital. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  5. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    Science.gov (United States)

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  6. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein

    OpenAIRE

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-01-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common caro...

  7. Effects of placement point of background music on shopping website.

    Science.gov (United States)

    Lai, Chien-Jung; Chiang, Chia-Chi

    2012-01-01

    Consumer on-line behaviors are more important than ever due to highly growth of on-line shopping. The purposes of this study were to design placement methods of background music for shopping website and examine the effect on browsers' emotional and cognitive response. Three placement points of background music during the browsing, i.e. 2 min., 4 min., and 6 min. from the start of browsing were considered for entry points. Both browsing without music (no music) and browsing with constant music volume (full music) were treated as control groups. Participants' emotional state, approach-avoidance behavior intention, and action to adjust music volume were collected. Results showed that participants had a higher level of pleasure, arousal and approach behavior intention for the three placement points than for no music and full music. Most of the participants for full music (5/6) adjusted the background music. Only 16.7% (3/18) participants for other levels turn off the background music. The results indicate that playing background music after the start of browsing is benefit for on-line shopping atmosphere. It is inappropriate to place background music at the start of browsing shopping website. The marketer must manipulated placement methods of background music for a web store carefully.

  8. Fitting in with the Team: Facilitative Mentors in Physiotherapy Student Placements

    Science.gov (United States)

    Hamshire, Claire; Wibberley, Christopher

    2017-01-01

    Clinical placements are central to physiotherapy students' education, providing an environment in which students can apply learning they have been introduced to in academic settings. However placement learning has been identified as fraught with problems and resultant stress, and there is limited evidence available on what exactly makes a good…

  9. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  10. Central-line-associated bloodstream infections in a resource-limited ...

    African Journals Online (AJOL)

    ... that reported from resource-limited settings, but exceeds that of high-income countries. Prolonged NICU stay and central-line insertion in the operating theatre were important risk factors for CLABSI development. Intensified neonatal staff training regarding CLABSI maintenance bundle elements and hand hygiene are key ...

  11. Impact of universal disinfectant cap implementation on central line-associated bloodstream infections.

    Science.gov (United States)

    Merrill, Katreena Collette; Sumner, Sharon; Linford, Lorraine; Taylor, Carrie; Macintosh, Christopher

    2014-12-01

    Central line-associated bloodstream infections (CLABSIs) result in increased length of stay, cost, and patient morbidity and mortality. One CLABSI prevention method is disinfection of intravenous access points. The literature suggests that placing disinfectant caps over needleless connectors decreases CLABSI risk. A quasi-experimental intervention study was conducted in a >430-bed trauma I center. In addition to an existing standard central line bundle, a new intervention consisting of a luer-lock disinfectant cap with 70% alcohol was implemented in all intravenous (IV) needleless connectors on patients with peripheral and central lines. Compliance to the disinfectant cap was monitored weekly. A generalized linear model using a Poisson distribution was fit to determine if there were significant relationships between CLABSIs and disinfectant cap use. Impacts on costs were also examined. The rate of CLABSI decreased following implementation of the disinfectant cap. The incidence rate ratios (.577, P = .004) for implementing the disinfectant caps was statistically significant, indicating that the rate of patient infections decreased by >40%. Increased compliance rates were associated with lower infection rates. Disinfectant cap use was associated with an estimated savings of almost $300,000 per year in the hospital studied. Use of a disinfectant cap on IV needleless connectors in addition to an existing standard central line bundle was associated with decreased CLABSI and costs. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Three rules suffice for good label placement

    NARCIS (Netherlands)

    Wagner, F.; Wolff, A.; Kapoor, V.; Strijk, T.

    2001-01-01

    The general label-placement problem consists in labeling a set of features (points, lines, regions) given a set of candidates (rectangles, circles, ellipses, irregularly shaped labels) for each feature. The problem arises when annotating classical cartographical maps, diagrams, or graph drawings.

  13. Immediate Implant Placement of a Single Central Incisor Using a CAD/CAM Crown-Root Form Technique: Provisional to Final Restoration.

    Science.gov (United States)

    Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj

    2017-02-01

    Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29

  14. DIM and diagnostic placement for NIF experiments

    International Nuclear Information System (INIS)

    Kalantar, D.

    1999-01-01

    The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition

  15. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  16. Children's cognitive representation of the mathematical number line.

    Science.gov (United States)

    Rouder, Jeffrey N; Geary, David C

    2014-07-01

    Learning of the mathematical number line has been hypothesized to be dependent on an inherent sense of approximate quantity. Children's number line placements are predicted to conform to the underlying properties of this system; specifically, placements are exaggerated for small numerals and compressed for larger ones. Alternative hypotheses are based on proportional reasoning; specifically, numerals are placed relative to set anchors such as end points on the line. Traditional testing of these alternatives involves fitting group medians to corresponding regression models which assumes homogenous residuals and thus does not capture useful information from between- and within-child variation in placements across the number line. To more fully assess differential predictions, we developed a novel set of hierarchical statistical models that enable the simultaneous estimation of mean levels of and variation in performance, as well as developmental transitions. Using these techniques we fitted the number line placements of 224 children longitudinally assessed from first to fifth grade, inclusive. The compression pattern was evident in mean performance in first grade, but was the best fit for only 20% of first graders when the full range of variation in the data are modeled. Most first graders' placements suggested use of end points, consistent with proportional reasoning. Developmental transition involved incorporation of a mid-point anchor, consistent with a modified proportional reasoning strategy. The methodology introduced here enables a more nuanced assessment of children's number line representation and learning than any previous approaches and indicates that developmental improvement largely results from midpoint segmentation of the line. © 2014 John Wiley & Sons Ltd.

  17. Geometric leaf placement strategies

    International Nuclear Information System (INIS)

    Fenwick, J D; Temple, S W P; Clements, R W; Lawrence, G P; Mayles, H M O; Mayles, W P M

    2004-01-01

    Geometric leaf placement strategies for multileaf collimators (MLCs) typically involve the expansion of the beam's-eye-view contour of a target by a uniform MLC margin, followed by movement of the leaves until some point on each leaf end touches the expanded contour. Film-based dose-distribution measurements have been made to determine appropriate MLC margins-characterized through an index d 90 -for multileaves set using one particular strategy to straight lines lying at various angles to the direction of leaf travel. Simple trigonometric relationships exist between different geometric leaf placement strategies and are used to generalize the results of the film work into d 90 values for several different strategies. Measured d 90 values vary both with angle and leaf placement strategy. A model has been derived that explains and describes quite well the observed variations of d 90 with angle. The d 90 angular variations of the strategies studied differ substantially, and geometric and dosimetric reasoning suggests that the best strategy is the one with the least angular variation. Using this criterion, the best straightforwardly implementable strategy studied is a 'touch circle' approach for which semicircles are imagined to be inscribed within leaf ends, the leaves being moved until the semicircles just touch the expanded target outline

  18. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters

    DEFF Research Database (Denmark)

    Partovi-Deilami, Kohyar; Nielsen, Jesper K.; Møller, Ann M.

    2016-01-01

    operated by nurse anesthetists for these patients. This prospective observational study with a pre/post design focused on inpatients with DIVA referred for PVC placement, a service provided by nurse anesthetists in most Scandinavian hospitals. The rate of success, procedure time, number of skin punctures......) with ultrasound. Procedure time was reduced from 20 to 10 minutes, discomfort was unchanged, and the median number of skin punctures decreased from 3 to 2. The incidence of central venous catheter placement dropped from 34% to 7%. Implementation of a training program and a mobile service in which nurse......, discomfort, catheter size, location, and incidence of central venous catheter placement are reported before and after implementation of a training program and a mobile service using ultrasound to place difficult-to-place PVCs. The success rate increased from 0% (0 of 33 patients) to 83% (58 of 70 patients...

  19. Clinical placements in mental health: a literature review.

    Science.gov (United States)

    Happell, Brenda; Gaskin, Cadeyrn J; Byrne, Louise; Welch, Anthony; Gellion, Stephen

    2015-01-01

    Gaining experience in clinical mental health settings is central to the education of health practitioners. To facilitate the ongoing development of knowledge and practice in this area, we performed a review of the literature on clinical placements in mental health settings. Searches in Academic Search Complete, CINAHL, Medline and PsycINFO databases returned 244 records, of which 36 met the selection criteria for this review. Five additional papers were obtained through scanning the reference lists of those papers included from the initial search. The evidence suggests that clinical placements may have multiple benefits (e.g. improving students' skills, knowledge, attitudes towards people with mental health issues and confidence, as well as reducing their fears and anxieties about working in mental health). The location and structure of placements may affect outcomes, with mental health placements in non-mental health settings appearing to have minimal impact on key outcomes. The availability of clinical placements in mental health settings varies considerably among education providers, with some students completing their training without undertaking such structured clinical experiences. Students have generally reported that their placements in mental health settings have been positive and valuable experiences, but have raised concerns about the amount of support they received from education providers and healthcare staff. Several strategies have been shown to enhance clinical placement experiences (e.g. providing students with adequate preparation in the classroom, implementing learning contracts and providing clinical supervision). Educators and healthcare staff need to work together for the betterment of student learning and the healthcare professions.

  20. [The unnecessary application of central venous catheterization in surgical patients].

    Science.gov (United States)

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  1. Do children without a known bleeding tendency undergoing PICC placement require coagulation laboratory testing?

    Science.gov (United States)

    Woodley-Cook, Joel; Amaral, Joao; Connolly, Bairbre; Brandão, Leonardo R

    2015-04-01

    Obtaining basic hemostatic laboratory investigations prior to peripherally inserted central catheter (PICC) insertion remains controversial, even if the procedure is converted to a tunneled central venous line (CVL) placement. To determine the value of pre-procedural blood screening (hemoglobin level, platelet count, aPTT/INR) in hospitalized children without a known bleeding diathesis. This retrospective review included pediatric patients undergoing PICC insertion who had both laboratory screening and post-PICC hemoglobin level. Two cohorts (A: 0-3 months; B: >3 months-18 years) were analyzed for procedural major/minor bleeding. Of 1,441 consecutive children identified during a 3-year period, 832 patients (226 in cohort A, 606 in cohort B) fulfilled the inclusion criteria. Overall, 36% (300/832) of the patients had at least one abnormal laboratory result. Only 0.2% (3/1,441) of patients required conversion to a central venous line. In cohort A no major bleeding occurred; the minor bleeding frequency was 30% (68/226). Neither abnormal laboratory results nor correction of abnormal laboratory results was associated with minor bleeding complications. The positive and negative predictive values (PPV/NPV) of having abnormal laboratory screening were 0.22 and 0.68, respectively. In cohort B the major bleeding frequency was 1% (6/606) but no patient required any blood transfusion; minor bleeding occurred in 29% (174/606). Neither abnormal laboratory results nor correction of abnormal laboratory results was associated with minor bleeding complications. The PPV and NPV of abnormal laboratory screening results were 0.24 and 0.72, respectively. Pre-procedural blood screening did not predict bleeding in hospitalized children without a known bleeding diathesis undergoing PICC insertion. The rarity of major bleeding complications and need for conversion to a central venous line did not support a need for laboratory screening.

  2. Thin blue lines: product placement and the drama of pregnancy testing in British cinema and television.

    Science.gov (United States)

    Olszynko-Gryn, Jesse

    2017-09-01

    This article uses the case of pregnancy testing in Britain to investigate the process whereby new and often controversial reproductive technologies are made visible and normalized in mainstream entertainment media. It shows how in the 1980s and 1990s the then nascent product placement industry was instrumental in embedding pregnancy testing in British cinema and television's dramatic productions. In this period, the pregnancy-test close-up became a conventional trope and the thin blue lines associated with Unilever's Clearblue rose to prominence in mainstream consumer culture. This article investigates the aestheticization of pregnancy testing and shows how increasingly visible public concerns about 'schoolgirl mums', abortion and the biological clock, dramatized on the big and small screen, propelled the commercial rise of Clearblue. It argues that the Clearblue close-up ambiguously concealed as much as it revealed; abstraction, ambiguity and flexibility were its keys to success.

  3. Use of Six Sigma strategies to pull the line on central line-associated bloodstream infections in a neurotrauma intensive care unit.

    Science.gov (United States)

    Loftus, Kelli; Tilley, Terry; Hoffman, Jason; Bradburn, Eric; Harvey, Ellen

    2015-01-01

    The creation of a consistent culture of safety and quality in an intensive care unit is challenging. We applied the Six Sigma Define-Measure-Analyze-Improve-Control (DMAIC) model for quality improvement (QI) to develop a long-term solution to improve outcomes in a high-risk neurotrauma intensive care unit. We sought to reduce central line utilization as a cornerstone in preventing central line-associated bloodstream infections (CLABSIs). This study describes the successful application of the DMAIC model in the creation and implementation of evidence-based quality improvement designed to reduce CLABSIs to below national benchmarks.

  4. North Central Transmission Line: Guidelines for the environmental impact statement

    International Nuclear Information System (INIS)

    1992-01-01

    Guidelines that Manitoba Hydro must follow in the preparation of the environmental impact statement on the proposed North Central Transmission Line (TCTL) project are presented. The project consists of a 138 kV transmission line, two 25 kV distribution lines, and related ancillary structures and facilities. The review process must be sensitive to cultural and community needs and must involve those most directly affected, and should be grounded in the impacted northern communities. The review should include a project background, the proposal, a description of the existing natural and socio-economic environment, and must address employment, education and training, impacts on renewable resource harvesting, environmental impacts, social impacts and economic impacts, legal/jurisdictional issues, infrastructure, mitigation and compensation, and environmental monitoring and follow-up. 1 fig., 20 tabs

  5. Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Gerasia, Roberta; Maggio, Simona; Luca, Angelo [Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Piazza, Marcello [Department of Anesthesia, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Tuzzolino, Fabio [Department of Information Technology, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy)

    2014-09-10

    Ultrasound-guided central venous puncture and fluoroscopic guidance during central venous catheter (CVC) positioning optimizes technical success and lowers the complication rates in children, and is therefore considered standard practice. The purpose of this study was to compare the radiation exposure levels recorded during CVC placement in children weighing less than 10 kg in procedures performed using an image intensifier-based angiographic system (IIDS) to those performed in a flat-panel detector-based interventional suite (FPDS). A retrospective review of 96 image-guided CVC placements, between January 2008 and October 2013, in 49 children weighing less than 10 kg was performed. Mean age was 8.2 ± 4.4 months (range: 1-22 months). Mean weight was 7.1 ± 2.7 kg (range: 2.5-9.8 kg). The procedures were classified into two categories: non-tunneled and tunneled CVC placement. Thirty-five procedures were performed with the IIDS (21 non-tunneled CVC, 14 tunneled CVC); 61 procedures were performed with the FPDS (47 non-tunneled CVC, 14 tunneled CVC). For non-tunneled CVC, mean DAP was 113.5 ± 126.7 cGy cm{sup 2} with the IIDS and 15.9 ± 44.6 cGy . cm{sup 2} with the FPDS (P < 0.001). For tunneled CVC, mean DAP was 84.6 ± 81.2 cGy . cm{sup 2} with the IIDS and 37.1 ± 33.5 cGy cm{sup 2} with the FPDS (P = 0.02). The use of flat-panel angiographic equipment reduces radiation exposure in small children undergoing image-guided CVC placement. (orig.)

  6. Application of HGSO to security based optimal placement and parameter setting of UPFC

    International Nuclear Information System (INIS)

    Tarafdar Hagh, Mehrdad; Alipour, Manijeh; Teimourzadeh, Saeed

    2014-01-01

    Highlights: • A new method for solving the security based UPFC placement and parameter setting problem is proposed. • The proposed method is a global method for all mixed-integer problems. • The proposed method has the ability of the parallel search in binary and continues space. • By using the proposed method, most of the problems due to line contingencies are solved. • Comparison studies are done to compare the performance of the proposed method. - Abstract: This paper presents a novel method to solve security based optimal placement and parameter setting of unified power flow controller (UPFC) problem based on hybrid group search optimization (HGSO) technique. Firstly, HGSO is introduced in order to solve mix-integer type problems. Afterwards, the proposed method is applied to the security based optimal placement and parameter setting of UPFC problem. The focus of the paper is to enhance the power system security through eliminating or minimizing the over loaded lines and the bus voltage limit violations under single line contingencies. Simulation studies are carried out on the IEEE 6-bus, IEEE 14-bus and IEEE 30-bus systems in order to verify the accuracy and robustness of the proposed method. The results indicate that by using the proposed method, the power system remains secure under single line contingencies

  7. Can the identification of an idle line facilitate its removal? A comparison between a proposed guideline and clinical practice.

    Science.gov (United States)

    Kara, Areeba; Johnson, Cynthia S; Murray, Michelle; Dillon, Jill; Hui, Siu L

    2016-07-01

    There are 250,000 cases of central line-associated blood stream infections in the United States annually, some of which may be prevented by the removal of lines that are no longer needed. To test the performance of criteria to identify an idle line as a guideline to facilitate its removal. Patients with central lines on the wards were identified. Criteria for justified use were defined. If none were met, the line was considered "idle." We proposed the guideline that a line may be removed the day following the first idle day and compared actual practice with our proposed guideline. One hundred twenty-six lines in 126 patients were observed. Eighty-three (65.9%) were peripherally inserted central catheters. Twenty-seven percent (n= 34) were placed for antibiotics. Seventy-six patients had lines removed prior to discharge. In these patients, the line was in place for 522 days, of which 32.7% were idle. The most common reasons to justify the line included parenteral antibiotics and meeting systemic inflammatory response (SIRS) criteria. In 11 (14.5%) patients, the line was removed prior to the proposed guideline. Most (n = 36, 47.4%) line removals were observed to be in accordance with our guideline. In another 29 (38.2%), line removal was delayed compared to our guideline. Idle days are common. Central line days may be reduced by the consistent daily reevaluation of a line's justification using defined criteria. The practice of routine central line placement for prolonged antibiotics and the inclusion of SIRS criteria to justify the line may need to be reevaluated. Journal of Hospital Medicine 2016;11:489-493. © 2016 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.

  8. At the Roots of Product Placement: The Mere Exposure Effect

    Directory of Open Access Journals (Sweden)

    Stefano Ruggieri

    2013-05-01

    Full Text Available The present study aims to analyze the effect of product placement on attitude change and takes into consideration psychological models of the mere exposure effect. A sample of high school students watched an excerpt from two widely-distributed movies in which several products were shown by using the technique known as product placement. The results indicate that students who saw the commercial brand liked the products more than those who didn’t see it. This effect, in line with the literature on the product placement effect, seems to be independent from the recognition of the brand in the movie excerpt. This study also shows that, in the high involvement condition, one exposure is enough to produce a positive attitude toward the brand.

  9. Keyword: Placement

    Science.gov (United States)

    Cassuto, Leonard

    2012-01-01

    The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…

  10. FtsZ placement in nucleoid-free bacteria.

    Directory of Open Access Journals (Sweden)

    Manuel Pazos

    Full Text Available We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO. A second septum placement mechanism, the MinCDE system (Min involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*, a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  11. FtsZ placement in nucleoid-free bacteria.

    Science.gov (United States)

    Pazos, Manuel; Casanova, Mercedes; Palacios, Pilar; Margolin, William; Natale, Paolo; Vicente, Miguel

    2014-01-01

    We describe the placement of the cytoplasmic FtsZ protein, an essential component of the division septum, in nucleoid-free Escherichia coli maxicells. The absence of the nucleoid is accompanied in maxicells by degradation of the SlmA protein. This protein, together with the nucleoid, prevents the placement of the septum in the regions occupied by the chromosome by a mechanism called nucleoid occlusion (NO). A second septum placement mechanism, the MinCDE system (Min) involving a pole-to-pole oscillation of three proteins, nonetheless remains active in maxicells. Both Min and NO act on the polymerization of FtsZ, preventing its assembly into an FtsZ-ring except at midcell. Our results show that even in the total absence of NO, Min oscillations can direct placement of FtsZ in maxicells. Deletion of the FtsZ carboxyl terminal domain (FtsZ*), a central hub that receives signals from a variety of proteins including MinC, FtsA and ZipA, produces a Min-insensitive form of FtsZ unable to interact with the membrane-anchoring FtsA and ZipA proteins. This protein produces a totally disorganized pattern of FtsZ localization inside the maxicell cytoplasm. In contrast, FtsZ*-VM, an artificially cytoplasmic membrane-anchored variant of FtsZ*, forms helical or repetitive ring structures distributed along the entire length of maxicells even in the absence of NO. These results show that membrane anchoring is needed to organize FtsZ into rings and underscore the role of the C-terminal hub of FtsZ for their correct placement.

  12. Standardizing central line safety: lessons learned for physician leaders.

    Science.gov (United States)

    Mueller, Jeff T; Wright, Alan J; Fedraw, Leslie A; Murad, M Hassan; Brown, Daniel R; Thompson, Kristine M; Flick, Randall; Seville, Maria Teresa A; Huskins, W Charles

    2014-01-01

    A comprehensive central venous catheter (CVC) safety program reduces mechanical and infectious complications and requires an integrated multidisciplinary effort. A multistate health care system implemented a discovery and diffusion project addressing CVC insertion, maintenance, and removal. Process and outcome measures were collected before and after the intervention. The project was completed in 12 months. It was associated with statistically significant improvement in 6 process measures and reduction in the rate of ICU central line-associated bloodstream infection (from 1.16 to 0.80 infections/1000 catheter days; incidence rate ratio = 0.69; 95% confidence interval = 0.51, 0.93). A comprehensive CVC standardization project increased compliance with several established best practices, was associated with improved outcomes, produced a refined definition of discovery and diffusion project components, and identified several discrete leadership principles that can be applied to future clinical improvement initiatives.

  13. Safe and easy power injection of contrast material through a central line

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, M.B.; Thoeni, R.F.; Goldberg, H.I.

    1998-01-01

    Power-assisted injection of contrast material into an antecubital vein is commonly used in CT and has been proven superior to manual injection. Power-assisted injection through a central line bares the risk of rupturing the line because manual control over the pressure applied by the power injector is lacking. We present a simple safety device which allows manual control of the pressure by means of an interposed three-way stopcock combined with a small syringe for pressure equalization. (orig.)

  14. Molecular and Recombination Lines in the Central Region of Sagittarius B2

    Science.gov (United States)

    Curtis, J.; Langston, G.

    2005-12-01

    We present observations of recombination and molecular lines towards Sgr B2 in the frequency range 12.4 to 15.0 GHz. In this frequency range, Hα , β , and γ lines, Heα recombination lines and emission from the SO molecule are detected. Molecular absorption lines from OH, H2CO, and CH3CO are detected at velocity 62±3 km/s. Measurements of the line widths and intensities are presented for the central region of Sgr B2. We detect two previously un-reported molecular absorption lines at 12388.0 and 14625.8 MHz (v=0. in LSR Frame). For selected recombination and molecular lines, we present images of a 10x10 arc-minute region centered on Sgr B2(M). We discuss the sources of three H2CO absorption features detected at 62±3, 6±5, and 100±10 km/s. This was done as a summer REU project in 2005 at the National Radio Astronomy Observatory's Green Bank site, and was funded by the National Science Foundation's REU program.

  15. [Doctor-nurse delegation of the insertion of central venous lines].

    Science.gov (United States)

    Cellupica, Mary

    2015-01-01

    The Léon Bérard Cancer Centre treats the disease in all its complexity with numerous disciplines such as surgery, medicine, radiotherapy, palliative care, home care, etc. The insertion of a central venous line is an essential part of cancer care and the nursing profession. It enables patients to have their treatment administered in the best possible conditions and without risk. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Engaging Frontline Staff in Central Line-Associated Bloodstream Infection Prevention Practice in the Wake of Superstorm Sandy.

    Science.gov (United States)

    Rosenberg, Rebecca E; Devins, Lea; Geraghty, Gail; Bock, Steven; Dugan, Christina A; Transou, Marjorie; Phillips, Michael; Lighter-Fisher, Jennifer

    2015-10-01

    Central venous catheters are crucial devices in the care of hospitalized children, both in and out of critical care units, but the concomitant risk of central line-associated bloodstream infection (CLABSI) affects 15,000 Americans annually. In 2012, CLABSI rates varied among units from 6.8/1,000 to 1.0/1,000 in a 109-bed children's service within NYU Langone Medical Center (NYULMC; New York City), a 1,069-bed tertiary care academic medical center. In response to variation in central line-related practices and infection prevention rates, a CLABSI Prevention Core Team began an effort to standardize central venous catheter (CVC) care across all pediatric units (ICU and non-ICU). Momentum in this quality improvement (QI) work was interrupted when Superstorm Sandy shuttered the flagship hospital, but the relatively decreased clinical load provided a "downtime" opportunity to address CLABSI prevention. The first phase of the collaborative effort, Booster 1, Planning/Initial Phase: Development of a Pediatric Central Venous Catheter Working Group, was followed by Booster 2, Maintenance/Sustaining Phase: Transitioning for Sustainability and Adopting Model for Improvement. Data in the subsequent 21 months after the temporary closure of the facility (January 2013-September 2014) showed an increase in maintenance bundle reliability. The inpatient CLABSI rate for patients<18 years decreased from an annual rate of 2.7/1,000 line days (2012) to 0.6/1,000 line days (2013) to 0.5/1,000 line days as of August 2014. There was a decrease in pediatric CLABSI events and no significant change in line days. Key elements contributing to initial success with evolving QI capacity and resources were likely multi-factorial, including staff and leadership engagement, culture change, consistent guidelines, and accountability by individuals and by our multidisciplinary core team.

  17. Questionnaire design: carry-over effects of overall acceptance question placement and pre-evaluation instructions on overall acceptance scores in central location tests.

    Science.gov (United States)

    Bastian, Mauresa; Eggett, Dennis L; Jefferies, Laura K

    2015-02-01

    Question placement and usage of pre-evaluation instructions (PEI) in questionnaires for food sensory analysis may bias consumers' scores via carry-over effects. Data from consumer sensory panels previously conducted at a central location, spanning 11 years and covering a broad range of food product categories, were compiled. Overall acceptance (OA) question placement was studied with categories designated as first (the first evaluation question following demographic questions), after nongustation questions (immediately following questions that do not require panelists to taste the product), and later (following all other hedonic and just-about-right [JAR] questions, but occasionally before ranking, open-ended comments, and/or intent to purchase questions). Each panel was categorized as having or not having PEI in the questionnaire; PEI are instructions that appear immediately before the first evaluation question and show panelists all attributes they will evaluate before receiving test samples. Postpanel surveys were administered regarding the self-reported effect of PEI on panelists' evaluation experience. OA scores were analyzed and compared (1) between OA question placement categories and (2) between panels with and without PEI. For most product categories, OA scores tended to be lower when asked later in the questionnaire, suggesting evidence of a carry-over effect. Usage of PEI increased OA scores by 0.10 of a 9-point hedonic scale point, which is not practically significant. Postpanel survey data showed that presence of PEI typically improved the panelists' experience. Using PEI does not appear to introduce a meaningful carry-over effect. © 2015 Institute of Food Technologists®

  18. Longitudinal development of number line estimation and mathematics performance in primary school children.

    Science.gov (United States)

    Friso-van den Bos, Ilona; Kroesbergen, Evelyn H; Van Luit, Johannes E H; Xenidou-Dervou, Iro; Jonkman, Lisa M; Van der Schoot, Menno; Van Lieshout, Ernest C D M

    2015-06-01

    Children's ability to relate number to a continuous quantity abstraction visualized as a number line is widely accepted to be predictive of mathematics achievement. However, a debate has emerged with respect to how children's placements are distributed on this number line across development. In the current study, different models were applied to children's longitudinal number placement data to get more insight into the development of number line representations in kindergarten and early primary school years. In addition, longitudinal developmental relations between number line placements and mathematical achievement, measured with a national test of mathematics, were investigated using cross-lagged panel modeling. A group of 442 children participated in a 3-year longitudinal study (ages 5-8 years) in which they completed a number-to-position task every 6 months. Individual number line placements were fitted to various models, of which a one-anchor power model provided the best fit for many of the placements at a younger age (5 or 6 years) and a two-anchor power model provided better fit for many of the children at an older age (7 or 8 years). The number of children who made linear placements also grew with age. Cross-lagged panel analyses indicated that the best fit was provided with a model in which number line acuity and mathematics performance were mutually predictive of each other rather than models in which one ability predicted the other in a non-reciprocal way. This indicates that number line acuity should not be seen as a predictor of math but that both skills influence each other during the developmental process. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Radiologic placement of hemodialysis central venous catheters: a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Schemmer, D.; Sadler, D.J.; Gray, R.R.; Saliken, J.C.; So, C.B. [Foothills Hospital, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)

    2001-04-01

    Typical indications for central venous catheters (CVCs) are hemodialysis (HD), apheresis, total parenteral nutrition, analgesia, chemotherapy, long-term antibiotic therapy and cases of difficult or absent peripheral venous access. One of the largest medical services requesting CVC insertion is nephrology for HD patients. Demographics dictate that the demand for CVCs will continue to grow over the next few decades, placing striking demands on interventional radiology departments. In our centre, interventional radiologists now place nearly all percutaneously inserted HD CVCs. Radiologists provide rapid access to CVC services with significantly fewer complications than CVCs placed by other clinicians. With the demand for CVC management increasing and available operating room time decreasing, many clinicians now refer CVC insertions to radiologists. As well, clinicians who ordinarily place their own lines often refer high-risk patients, such as those who are obese or uncooperative and those with burns or coagulopathy. Our experience, derived from over 7000 CVC insertions, manipulations and removals, has allowed us to continually progress and improve our techniques, many of which are summarized here. (author)

  20. Advantages and disadvantages of peripherally inserted central venous catheters (PICC) compared to other central venous lines: a systematic review of the literature.

    Science.gov (United States)

    Johansson, Eva; Hammarskjöld, Fredrik; Lundberg, Dag; Arnlind, Marianne Heibert

    2013-06-01

    The use of central venous lines carries a significant risk for serious complications and high economic costs. Lately, the peripherally inserted central venous catheter (PICC) has gained in popularity due to presumed advantages over other central venous lines. The aim of this systematic literature review was to identify scientific evidence justifying the use of PICC. The literature review was performed according to the principles of Cochrane Collaboration. The electronic literature search included common databases up to March 2011. Only those studies rated as high or moderate quality were used for grading of evidence and conclusions. The search resulted in 827 abstracts, 48 articles were read in full text, and 11 met the inclusion criteria. None of the articles was classified as high quality and two had moderate quality. The results of these two studies indicate that PICC increases the risk for deep venous thrombosis (DVT), but decreases the risk for catheter occlusion. The quality of scientific evidence behind these conclusions, however, was limited. Due to the lack of studies with sufficiently high quality, questions such as early complications, patient satisfaction and costs could not be answered. We conclude that although PICCs are frequently used in oncology, scientific evidence supporting any advantage or disadvantage of PICC when comparing PICC with traditional central venous lines is limited, apart from a tendency towards increased risk for DVT and a decreased risk for catheter occlusion with PICC.

  1. Spatial patterns in Central Asian climate and equilibrium line altitudes

    International Nuclear Information System (INIS)

    Rupper, Summer; Koppes, Michele

    2010-01-01

    A suite of general circulation model (GCM) simulations and a glacier equilibrium line altitude (ELA) model are compared to reconstructed glacier advances from geomorphic data and used to test the sensitivity of Central Asian glaciers to simulated climate changes at the Last Glacial Maximum (LGM). Results highlight temperature changes as being the most important influence on glacier ELA changes during the LGM. With the exception of the southern Himalaya, for much of Central Asia there is consistency between GCMs for simulated LGM temperature changes, with a mean cooling of 4 0 C. Further research will necessarily need to focus on detailed analysis of the inter-model differences in temperature in the southern Himalaya, and acquiring additional paleoclimate proxies in the region in order to further constrain the GCMs.

  2. A Labeling Model Based on the Region of Movability for Point-Feature Label Placement

    Directory of Open Access Journals (Sweden)

    Lin Li

    2016-09-01

    Full Text Available Automatic point-feature label placement (PFLP is a fundamental task for map visualization. As the dominant solutions to the PFLP problem, fixed-position and slider models have been widely studied in previous research. However, the candidate labels generated with these models are set to certain fixed positions or a specified track line for sliding. Thus, the whole surrounding space of a point feature is not sufficiently used for labeling. Hence, this paper proposes a novel label model based on the region of movability, which comes from plane collision detection theory. The model defines a complete conflict-free search space for label placement. On the premise of no conflict with the point, line, and area features, the proposed model utilizes the surrounding zone of the point feature to generate candidate label positions. By combining with heuristic search method, the model achieves high-quality label placement. In addition, the flexibility of the proposed model enables placing arbitrarily shaped labels.

  3. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  4. Adaptive and Decentralized Operator Placement for In-Network Query Processing

    DEFF Research Database (Denmark)

    Bonfils, B; Bonnet, Philippe

    2003-01-01

    . In this paper, we show that this problem is a variant of the task assignment problem for which polynomial algorithms have been developed. These algorithms are however centralized and cannot be used in a sensor network. We describe an adaptive and decentralized algorithm that progressively refines the placement...

  5. On-line satellite/central computer facility of the Multiparticle Argo Spectrometer System

    International Nuclear Information System (INIS)

    Anderson, E.W.; Fisher, G.P.; Hien, N.C.; Larson, G.P.; Thorndike, A.M.; Turkot, F.; von Lindern, L.; Clifford, T.S.; Ficenec, J.R.; Trower, W.P.

    1974-09-01

    An on-line satellite/central computer facility has been developed at Brookhaven National Laboratory as part of the Multiparticle Argo Spectrometer System (MASS). This facility consisting of a PDP-9 and a CDC-6600, has been successfully used in study of proton-proton interactions at 28.5 GeV/c. (U.S.)

  6. Central line-associated blood stream infections in pediatric ICUs: Longitudinal trends and compliance with bundle strategies

    Science.gov (United States)

    Edwards, Jeffrey D; Herzig, Carolyn TA; Liu, Hangsheng; Pogorzelska-Maziarz, Monika; Zachariah, Philip; Dick, Andrew W; Saiman, Lisa; Stone, Patricia W; Furuya, E Yoko

    2015-01-01

    Background Knowing the temporal trend central line-associated bloodstream infection (CLABSI) rates among U.S. pediatric intensive care units (PICU), the current extent of CL bundle compliance, and the impact of compliance on rates is necessary to understand what has been accomplished and can be improved in CLABSI prevention. Methods Longitudinal study of PICUs in National Healthcare Safety Network hospitals and a cross-sectional survey of directors/managers of infection prevention & control departments regarding PICU CLABSI prevention practices, including self-reported compliance with elements of central line bundles. Associations between 2011/12 PICU CLABSI rates and infection prevention practices were examined. Results Reported CLABSI rates decreased during the study period, from 5.8 per 1000 line days in 2006 to 1.4 in 2011/12 (Pprevention practices, only 35% of those with policies reported ≥95% compliance. PICUs with ≥95% compliance with central line infection prevention policies had lower reported CLABSI rates, but this association was statistically insignificant. Conclusions There was a non-significant trend in decreasing CLABSI rates as PICUs improved bundle policy compliance. Given that few PICUs reported full compliance with these policies, PICUs increasing their efforts to comply with these policies may help reduce CLABSI rates. PMID:25952048

  7. Sensitivity of Coastal Environments and Wildlife to Spilled Oil: Central California: FISHL (Fish Lines)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains sensitive biological resource data for anadromous fish and rare fish species occurrences in Central California. Vector lines in this data set...

  8. Antiseptic barrier cap effective in reducing central line-associated bloodstream infections : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Voor In 't Holt, Anne F; Helder, Onno K; Vos, Margreet C; Schafthuizen, Laura; Sülz, Sandra; van den Hoogen, Agnes; Ista, Erwin

    2017-01-01

    BACKGROUND: Microorganisms can intraluminally access a central venous catheter via the catheter hub. The catheter hub should be appropriately disinfected to prevent central line-associated bloodstream infections (CLABSIs). However, compliance with the time-consuming manual disinfection process is

  9. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  10. Predictors of Unattempted Central Venous Catheterization in Septic Patients Eligible for Early Goal-directed Therapy

    Directory of Open Access Journals (Sweden)

    David R. Vinson

    2014-02-01

    Full Text Available Introduction: Central venous catheterization (CVC can be an important component of the management of patients with severe sepsis and septic shock. CVC, however, is a time- and resource-intensive procedure associated with serious complications. The effects of the absence of shock or the presence of relative contraindications on undertaking central line placement in septic emergency department (ED patients eligible for early goal-directed therapy (EGDT have not been well described. We sought to determine the association of relative normotension (sustained systolic blood pressure >90 mmHg independent of or in response to an initial crystalloid resuscitation of 20 mL/kg, obesity (body mass index [BMI] ≥30, moderate thrombocytopenia (platelet count <50,000 per μL, and coagulopathy (international normalized ratio ≥2.0 with unattempted CVC in EGDT-eligible patients. Methods: This was a retrospective cohort study of 421 adults who met EGDT criteria in 5 community EDs over a period of 13 months. We compared patients with attempted thoracic (internal jugular or subclavian CVC with those who did not undergo an attempted thoracic line. We also compared patients with any attempted CVC (either thoracic or femoral with those who did not undergo any attempted central line. We used multivariate logistic regression analysis to calculate adjusted odd ratios (AORs. Results: In our study, 364 (86.5% patients underwent attempted thoracic CVC and 57 (13.5% did not. Relative normotension was significantly associated with unattempted thoracic CVC (AOR 2.6 95% confidence interval [CI], 1.6-4.3, as were moderate thrombocytopenia (AOR 3.9; 95% CI, 1.5-10.1 and coagulopathy (AOR 2.7; 95% CI, 1.3-5.6. When assessing for attempted catheterization of any central venous site (thoracic or femoral, 382 (90.7% patients underwent attempted catheterization and 39 (9.3% patients did not. Relative normotension (AOR 2.3; 95% CI, 1.2-4.5 and moderate thrombocytopenia (AOR 3.9; 95

  11. Focal hot spot induced by a central subclavian line on bone scan.

    Science.gov (United States)

    Moslehi, Masood; Cheki, Mohsen; Dehghani, Tohid; Eftekhari, Mansoureh

    2014-01-01

    The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal) variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration) and the interpreting physicians should be aware of the impact of technical factors on image quality.

  12. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  13. Managing disclosure following recent-onset psychosis: utilizing the individual placement and support model.

    Science.gov (United States)

    Allott, Kelly A; Turner, Luana R; Chinnery, Gina L; Killackey, Eoin J; Nuechterlein, Keith H

    2013-08-01

    Individual Placement and Support is the most defined and evidence-based approach to supported employment for severe mental illness, including recent-onset psychosis. However, there is limited evidence or detailed guidelines informing the management of mental illness disclosure to educators or employers when delivering individual placement and support. In this paper, we describe the initial disclosure preferences of young people with recent-onset psychosis enrolled in individual placement and support and provide guidance for managing disclosure when delivering Individual Placement and Support with this population. Drawing from sites in Melbourne, Australia and Los Angeles, USA, clients' initial disclosure preferences were examined. We describe approaches to providing individual placement and support when no disclosure is permitted compared with when disclosure is permitted, including two illustrative case vignettes. No disclosure of mental illness or disability was requested by 54-59% of clients; 41-46% of clients permitted partial or complete disclosure. The 'no disclosure' scenario required the individual placement and support worker to provide support 'behind the scenes', whereas when disclosure was permitted, the individual placement and support worker could have contact with instructors/employers and work 'on the front lines'. The case vignettes illustrate how both approaches can lead to successful vocational outcomes. We found that Individual Placement and Support can be provided in an educative, flexible, creative and collaborative manner according to client disclosure preferences. We suggest that disclosure preferences do not prevent successful vocational outcomes, although this supposition requires empirical investigation. © 2013 Wiley Publishing Asia Pty Ltd.

  14. Can children undergoing ophthalmologic examinations under anesthesia be safely anesthetized without using an IV line?

    Directory of Open Access Journals (Sweden)

    Vigoda M

    2011-04-01

    Full Text Available Michael M Vigoda, Azeema Latiff, Timothy G Murray, Jacqueline L Tutiven, Audina M Berrocal, Steven GayerBascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USAPurpose: To document that with proper patient and procedure selection, children undergoing general inhalational anesthesia for ophthalmologic exams (with or without photos, ultrasound, laser treatment, peri-ocular injection of chemotherapy, suture removal, and/or replacement of ocular prosthesis can be safely anesthetized without the use of an intravenous (IV line. Children are rarely anesthetized without IV access placement. We performed a retrospective study to determine our incidence of IV access placement during examinations under anesthesia (EUA and the incidence of adverse events that required intraoperative IV access placement.Methods: Data collected from our operating room (OR information system includes but is not limited to diagnosis, anesthesiologist, surgeon, and location of IV catheter (if applicable, patient’s date of birth, actual procedure, and anesthesia/procedure times. We reviewed the OR and anesthetic records of children (>1 month and <10 years who underwent EUAs between January 1, 2003 and May 31, 2009. We determined the percentage of children who were anesthetized without IV access placement, as well as the incidence of any adverse events that required IV access placement, intraoperatively.Results: We analyzed data from 3196 procedures performed during a 77-month period. Patients’ ages ranged from 1 month to 9 years. Overall, 92% of procedures were performed without IV access placement. Procedure duration ranged from 1–39 minutes. Reasons for IV access placement included parental preference for antinausea medication and/or attending preference for IV access placement. No child who underwent anesthesia without an IV line had an intraoperative adverse event requiring insertion of an IV line.Conclusion: Our data suggest that for

  15. Data-driven sensor placement from coherent fluid structures

    Science.gov (United States)

    Manohar, Krithika; Kaiser, Eurika; Brunton, Bingni W.; Kutz, J. Nathan; Brunton, Steven L.

    2017-11-01

    Optimal sensor placement is a central challenge in the prediction, estimation and control of fluid flows. We reinterpret sensor placement as optimizing discrete samples of coherent fluid structures for full state reconstruction. This permits a drastic reduction in the number of sensors required for faithful reconstruction, since complex fluid interactions can often be described by a small number of coherent structures. Our work optimizes point sensors using the pivoted matrix QR factorization to sample coherent structures directly computed from flow data. We apply this sampling technique in conjunction with various data-driven modal identification methods, including the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD). In contrast to POD-based sensors, DMD demonstrably enables the optimization of sensors for prediction in systems exhibiting multiple scales of dynamics. Finally, reconstruction accuracy from pivot sensors is shown to be competitive with sensors obtained using traditional computationally prohibitive optimization methods.

  16. A PATIENT WITH EPIDERMAL CYST IN MANDIBULA, SIMULTANEOUSLY ENUCLEATION OF EPIDERMAL CYST AND IMPLANT PLACEMENT:

    OpenAIRE

    Terzi, Mithat; Karaaslan, Fatih; Çalık, Muhammed; Dilsiz, Alparslan; Altun, Eren

    2015-01-01

    Dermoid cysts are malformations that rarely seen in oral mucosa and can be defined as an epidermoid when lining presents only epithelium. Epidermoid and dermoid cysts are rarely seen in intraosseous and there was a few report about their presentation in the jaws. The development in implant surfaces and surgical techniques has led to changes in treatment protocol such as immediate implant placement. Immediate implant placement has some advantages such as, reduction in the time of treat- ment a...

  17. Optimum distributed generation placement with voltage sag effect minimization

    International Nuclear Information System (INIS)

    Biswas, Soma; Goswami, Swapan Kumar; Chatterjee, Amitava

    2012-01-01

    Highlights: ► A new optimal distributed generation placement algorithm is proposed. ► Optimal number, sizes and locations of the DGs are determined. ► Technical factors like loss, voltage sag problem are minimized. ► The percentage savings are optimized. - Abstract: The present paper proposes a new formulation for the optimum distributed generator (DG) placement problem which considers a hybrid combination of technical factors, like minimization of the line loss, reduction in the voltage sag problem, etc., and economical factors, like installation and maintenance cost of the DGs. The new formulation proposed is inspired by the idea that the optimum placement of the DGs can help in reducing and mitigating voltage dips in low voltage distribution networks. The problem is configured as a multi-objective, constrained optimization problem, where the optimal number of DGs, along with their sizes and bus locations, are simultaneously obtained. This problem has been solved using genetic algorithm, a traditionally popular stochastic optimization algorithm. A few benchmark systems radial and networked (like 34-bus radial distribution system, 30 bus loop distribution system and IEEE 14 bus system) are considered as the case study where the effectiveness of the proposed algorithm is aptly demonstrated.

  18. Placement of acid spoil materials

    Energy Technology Data Exchange (ETDEWEB)

    Pionke, H B; Rogowski, A S

    1982-06-01

    Potentially there are several chemical and hydrologic problems associated with placement of acid spoil materials. The rationale for a deep placement well below the soil surface, and preferably below a water table, is to prevent or minimize oxidation of pyrite to sulfuric acid and associated salts by reducing the supply of oxygen. If, however, substantial sulfuric acid or associated salts are already contained within the spoil because of present or previous mining, handling and reclamation operations (or if large supplies of indigenous salts exist, placement below a water table) may actually increase the rate of acid and salt leaching. Specific placement of acid- and salt-containing spoil should be aimed at preventing contact with percolating water or rising water tables. We recommend placement based on chemical and physical spoil properties that may affect water percolation O/sub 2/ diffusion rates in the profile. Both the deeper placement of acid spoil and coarser particle size can substantially reduce the amount of acid drainage. Placement above the water table with emphasis on percolate control may be better for high sulfate spoils, while placement below the non-fluctuating water table may be better for pyritic spoils.

  19. Depositional facies mosaics and their time lines in Lower Ordovician carbonates of central Appalachians

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, C.T.; Goldhammer, R.K.; Hardie, L.A.

    1985-02-01

    A comparative sedimentology and facies stratigraphy study of the Lower Ordovician carbonate of the central Appalachians (Beekmantown Group and equivalents) has been carried out. Our approach used subfacies (rock record of subenvironments) as the basin units of section measurement. The authors differentiated related sets of subfacies into larger facies units (rock record of environments). Facies were then correlated from section to section using fossils and lithostratigraphy to make a 3-dimensional facies mosaic. Within this mosaic, time lines were constructed using onlap-offlap tongues and cyclic sequences. These time lines cut across facies boundaries. Using this approach, the authors have established that the lower 600 m of the Lower Ordovician carbonate sequence is made up of 4 main facies: (1) cyclic laminite facies composed of a package of shoaling-upward shelf lagoon-peritidal cycles, (2) thin-bedded grainstone facies deposited in a shelf lagoon, (3) Renalcis bioherm facies recording a shelf lagoon patch-reef environment, and (4) Epiphyton bioherm facies recording a shelf-edge reef system. The distribution of these facies along time lines across the strike of the central Appalachians is markedly zoned. Epiphyton bioherm facies dominate the eastern margin while cyclic laminite facies dominate the western margin, with thin-bedded grainstone and Renalcis bioherm facies making up the central belt. This zonation of facies is a typical shallow carbonate shelf system with fringing reefs along the eastern, seaward margin and tidal flats along the western, landward margin. Vertical distribution of these facies across strike records 3 major sea level changes during deposition of the lower 600 m of this extensive Lower Ordovician carbonate shelf.

  20. International clinical placements for Australian undergraduate nursing students: A systematic thematic synthesis of the literature.

    Science.gov (United States)

    Browne, Caroline A; Fetherston, Catherine M; Medigovich, Kristina

    2015-10-01

    International clinical placements provide undergraduate nursing students with the opportunity to experience or practice nursing care in diverse countries, settings, and cultures. This systematic review aims to ascertain the current knowledge on international clinical placements offered by undergraduate nursing programs in Australia. It seeks to explore three questions: (1) How have previous experiences of nursing students' international clinical placements been described? (2) How have participants and stakeholders determined if the placement has been successful? And (3) What benefits or challenges have been identified by stakeholders as a result of participating in international clinical placements? A systematic thematic synthesis was undertaken. A search of electronic databases including CINAHL, Proquest Central, Scopus, PubMed, and Health Collection was undertaken between September and October 2014. Key terms including 'international clinical placement', 'study abroad', 'international exchange', 'nursing', and 'Australia' were used to identify articles that appeared in peer-reviewed English language journals and that explored international clinical placements offered to undergraduate nursing students by Australian universities. Eight studies were identified that meet the inclusion criteria, and through thematic analysis, five key themes were identified including developing cultural awareness and competence, providing a global perspective on health care, translation of theory to practice, growing personally through reflection, and overcoming apprehension to successfully meet the challenge. A comparison search of literature from Canada and the United Kingdom revealed that similar themes occurred internationally. Although personal successes were identified by students undertaking international clinical placement, further research is required to identify all stakeholder experiences including those of the educators, the educational institutions, and travel providers

  1. A new tectonic model for the Cameroon Line, Central Africa

    Science.gov (United States)

    Moreau, C.; Regnoult, J.-M.; Déruelle, B.; Robineau, B.

    1987-10-01

    The Cameroon Line, a major geological feature in Central Africa, has been considered successively as a series of horsts and grabens, a continental rift and a mega-shear zone. It is marked out by about 60 anorogenic complexes and a dozen volcanic centres, all of which have alkaline affinity. Remote sensing allows us recognition of the main lineament trends: N70°, N-S, N135° and E-W, while autocorrelation analysis reveals a major fault zone striking N30° in western Cameroon and N15° in the northern region. A mega left-lateral shear zone is the model that best accounts for the fracture pattern and associated features such as linear and circular structures alignment of subvolcanic complexes, syntectonic leucogranites marking out older shear zones and vein dykes. The N70° Adamawa fault zone, a Pan-African fracture reworked during Albian-Aptian times, is the only shear zone of continental scale that could have initiated "en echelon" mega-tension gashes within the Cameroon Line during a Cainozoic left-lateral transcurrent movement.

  2. Sensitivity of Coastal Environments and Wildlife to Spilled Oil: Central California: HYDRO (Hydrography Lines and Polygons)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains vector lines and polygons representing coastal hydrography used in the creation of the Environmental Sensitivity Index (ESI) for Central...

  3. Harris lines of the tibia across centuries: a comparison of two populations, medieval and contemporary in Central Europe

    International Nuclear Information System (INIS)

    Ameen, S.; Vock, P.; Anderson, S.E.; Staub, L.; Ulrich, S.; Ballmer, F.

    2005-01-01

    To determine the incidence of Harris lines in two medieval populations which inhabited the Canton of Berne, in Central Switzerland, and to compare the results with those of a contemporary population living in the same geographical area. A simplified method is described for measuring the age of the individual at the time of formation of Harris lines, with possible future applications. Radiographs of 112 well-preserved tibiae of skeletons of two medieval populations from the eighth to fifteenth centuries were reviewed for the incidence of Harris lines. The results were compared with those of 138 current patients living in the same geographic location in Central Switzerland. Age and gender of the medieval individual were determined using known anthropological methods. Age of bone at the time of formation of Harris lines was estimated according to the method of Maat. Harris lines were found in 88 of 112 (80%) of the examined medieval skeletons and in 28 of 138 (20%) of the living individuals. Higher incidences of Harris lines were found at the age of 2 years and at ages between 8 and 12 years in both populations. No gender difference was found regarding the incidence of Harris lines. In both populations the occurrence of Harris lines was associated with certain diseases such as degenerative bone disease, trauma, osteoporosis, rheumatoid arthritis, peripheral vascular diseases, rickets and bony deformities. (orig.)

  4. Harris lines of the tibia across centuries: a comparison of two populations, medieval and contemporary in Central Europe

    Energy Technology Data Exchange (ETDEWEB)

    Ameen, S.; Vock, P.; Anderson, S.E. [University Hospital of Bern, Department of Diagnostic Radiology, Bern (Switzerland); Staub, L.; Ulrich, S. [University of Bern, Institute of Historical Medicine, Bern (Switzerland); Ballmer, F. [University Hospital of Bern, Department of Orthopaedics, Bern (Switzerland)

    2005-05-01

    To determine the incidence of Harris lines in two medieval populations which inhabited the Canton of Berne, in Central Switzerland, and to compare the results with those of a contemporary population living in the same geographical area. A simplified method is described for measuring the age of the individual at the time of formation of Harris lines, with possible future applications. Radiographs of 112 well-preserved tibiae of skeletons of two medieval populations from the eighth to fifteenth centuries were reviewed for the incidence of Harris lines. The results were compared with those of 138 current patients living in the same geographic location in Central Switzerland. Age and gender of the medieval individual were determined using known anthropological methods. Age of bone at the time of formation of Harris lines was estimated according to the method of Maat. Harris lines were found in 88 of 112 (80%) of the examined medieval skeletons and in 28 of 138 (20%) of the living individuals. Higher incidences of Harris lines were found at the age of 2 years and at ages between 8 and 12 years in both populations. No gender difference was found regarding the incidence of Harris lines. In both populations the occurrence of Harris lines was associated with certain diseases such as degenerative bone disease, trauma, osteoporosis, rheumatoid arthritis, peripheral vascular diseases, rickets and bony deformities. (orig.)

  5. Neuro-critical care: a valuable placement during foundation and early neurosurgical training.

    Science.gov (United States)

    Dyson, Edward W; Kolias, Angelos G; Burnstein, Rowan M; Hutchinson, Peter J A; Garnett, Matthew R; Menon, David K; Trivedi, Rikin A

    2014-10-01

    Neurosciences critical care units (NCCUs) present a unique opportunity to junior trainees in neurosurgery as well as foundation trainees looking to gain experience in the management of critically ill patients with neurological conditions. Placements in NCCUs are undertaken in the early years of neurosurgical training or during neurosciences themed foundation programmes. We sought to quantify the educational benefits of such placements from the trainee perspective. Thirty-two trainees who had undertaken placements at Foundation Year 2 (FY2) to Specialty Trainee Year 3 (ST3) level between August 2009 and April 2013 were invited to take part in an online questionnaire survey. Competence in individual skills was self-rated on a ranked scale from one (never observed) to five (performed unsupervised) both before and after the placement. Trainees were also asked a series of questions pertaining to their ability to manage common neurosurgical conditions, as well as the perceived educational rigour of their placement. Twenty-three responses were received. Eighteen responses were from FY2s and seven were from ST1-3 level trainees. Following their placements, 100% of respondents felt better equipped to deal with neurosurgical and neurological emergencies and cranial trauma. Most felt better equipped to manage hydrocephalus (95.7%), polytrauma patients (95.7%), spontaneous intracranial haemorrhage (91.3%) and spinal trauma (82.6%). Significant increases were seen in experience in all practical skills assessed. These included central venous catheterisation (p training programme as well as in the Foundation Programme. This supports the incorporation of a four- to six-month NCCU rotation in early years training as educationally valuable.

  6. Sensitivity of Coastal Environments and Wildlife to Spilled Oil: Central California: REPTILEL (Reptile and Amphibian Lines)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains sensitive biological resource data for amphibians and reptiles in Central California. Vector lines in this data set represent general stream...

  7. Why good placements matter: Pre-placement and placement risk factors associated with mental health disorders in pre-school children in foster care.

    Science.gov (United States)

    Hillen, Thomas; Gafson, Leonie

    2015-07-01

    Pre-school children placed in local authority care show elevated rates of mental health disorders when compared to the general population. This study investigated risk factors for mental health disorders relating to the period prior to entering care and while in care. A representative sample of 43 children in care aged 0-72 months in an inner London borough underwent comprehensive multidimensional assessments. Presence of emotional, behavioural, attachment and adaptive disorders was ascertained. Exposure to two pre-placement risk factors and six placement risk factors was compared between children with and without a disorder. A total of 26 children (60.5%) had at least one mental health disorder. The two pre-placement risk factors, multiple types of maltreatment and entry into care after the age of 6 months, were both significantly associated with mental health disorders. The three placement risk factors of sudden placement moves, multiple placement moves and child-carer alienation showed a significant association with mental health disorders. There was a strong correlation between the number of risk factors and the number of co-morbid mental health disorders per child (r = .67, p school mental health. © The Author(s) 2014.

  8. Patients with Central Lines - What You Need to Know to Avoid a Bloodstream Infection PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second PSA is based on the March, 2011 CDC Vital Signs report which indicates bloodstream infections in patients with central lines are largely preventable when healthcare providers use CDC-recommended infection control steps.

  9. Sediment Placement Areas 2012

    Data.gov (United States)

    California Natural Resource Agency — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  10. Sediment Placement Areas 2012

    Data.gov (United States)

    California Department of Resources — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  11. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  12. Relationship between crown-root angulation (collum angle) of maxillary central incisors in Class II, division 2 malocclusion and lower lip line.

    Science.gov (United States)

    Srinivasan, Bhadrinath; Kailasam, Vignesh; Chitharanjan, Arun; Ramalingam, Arthi

    2013-01-01

    The present study aimed to measure the magnitude of the collum angle (crown-root angulation) of maxillary central incisors present in Class II, division 2 malocclusion and to relate the changes in its magnitude with variations in the lower lip line. A set of 120 conventional lateral cephalograms were selected and divided into three groups of 40 each based on the type of malocclusion presented: Class II, division 2 (group 1); Class II, division 1 (group 2); and Class I (group 3). The collum angle of the maxillary central incisor was measured, and the lower lip line was recorded. Analysis of variance (ANOVA) revealed that the mean collum angle was statistically significantly different in the three groups. The mean collum angle was greatest in Class II, division 2 malocclusion (group 1). The mean collum angles were 3.24 ± 4.69 degrees, 0.95 ± 1.06 degrees, and 1.05 ± 1.50 degrees in groups 1, 2, and 3 respectively. In χ ² test comparison of the location of the lower lip line (incisal, middle, or apical third of the central incisor) among the three groups, the lower lip line was found to contact the middle third of the central incisor most frequently in Class II, division 2 malocclusion. ANOVA followed by Tukey honestly significant difference (HSD) test showed that the mean collum angle is significantly increased when the lower lip is in the middle third (P lower lip line suggest a probable etiologic role of the lower lip line in the development of the collum angle.

  13. Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients.

    Science.gov (United States)

    Gnannt, Ralph; Connolly, Bairbre L; Parra, Dimitri A; Amaral, Joao; Moineddin, Rahim; Thakor, Avnesh S

    2016-10-01

    The position of the tip of a peripherally inserted central catheter (PICC) is crucial; malposition can lead to malfunction of the line or life-threatening events (e.g., arrhythmias, perforation). To determine what factors other than arm position and accessed vein might influence the tip position of a PICC. Inclusion criteria were upper limb PICC placement, body weight central tip movement in rib units. We included 112 children who received a PICC (42 girls/70 boys, mean age 31±13 months, mean weight 6.5±4.9 kg). The overall range of central tip movement was -1 to +4 rib units (mean +0.8±0.7 rib units). Silicone PICCs moved significantly less than polyurethane PICCs (Pcentral tip movement of a PICC (P>0.05). Silicone PICCs and PICCs inserted into the cephalic vein move less than PICCs made of polyurethane and PICCs inserted into the brachial and basilic veins. These findings might assist operators in deciding which PICC to place in children in a given clinical context.

  14. Boat boarding ladder placement

    Science.gov (United States)

    1998-04-01

    Presented in three volumes; 'Boat Boarding Ladder Placement,' which explores safety considerations including potential for human contact with a rotating propeller; 'Boat Handhold Placement,' which explores essential principles and methods of fall con...

  15. Product placement and its aplication in foreign film

    OpenAIRE

    Vaněk, Tomáš

    2010-01-01

    Marketing and commertial communication and position of product placement within it, legislature governing product placement and its aplication, history of product placement, forms of product placement, use of product placement within marketing campaign, aplication of product placement in movie Casino Royale.

  16. Pain and efficacy of local anesthetics for central venous access

    Directory of Open Access Journals (Sweden)

    William C Culp Jr

    2008-11-01

    Full Text Available William C Culp Jr1, Mohammed Yousaf2, Benjamin Lowry1, Timothy C McCowan3, William C Culp21Division of Cardiothoracic Anesthesiology, Scott and White Hospital, The Texas A&M University College of Medicine, Temple, TX, USA; 2Division of Interventional Radiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA; 3Department of Radiology, University of Mississippi Medical Center, Jackson, MS, USAPurpose: To compare pain during injection and efficacy of analgesia of local anesthetics during central venous line placement.Methods: Sixty-two patients were studied in a randomized, double-blinded prospective fashion. Patients received 1% lidocaine (L, buffered 1% lidocaine (LB, or 2% chloroprocaine (CP injected around the internal jugular vein for procedural analgesia for central venous access. Patients reported pain via a standard linear visual analog scale, with 0 representing no pain and 10 being the worst pain imaginable.Results: Overall patient perception of pain was better with CP and L than LB with mean scores of CP 2.4, L 2.6, LB 4.2. Pain with injection mean scores were CP 2.1, L 2.5, LB 3.2. Pain with catheter placement scores were CP 2.5, L 1.7, LB 3.4. Operator assessment of overall pain values were CP 1.9, L 2.2, LB 3.4. LB consistently scored the worst, though compared with CP, this only reached statistical significance in overall patient pain and pain at catheter insertion compared with L.Conclusion: Though chloroprocaine scored better than lidocaine in 3 of 4 parameters, this trend did not achieve statistical significance. Adding sodium bicarbonate to lidocaine isn’t justified in routine practice, nor is routine replacement of lidocaine with chloroprocaine.Keywords: local anesthesia, analgesia, central venous access, lidocaine, chloroprocaine

  17. Patients with Central Lines — What You Need to Know to Avoid a Bloodstream Infection

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the March, 2011 CDC Vital Signs report which indicates bloodstream infections in patients with central lines are largely preventable when healthcare providers use CDC-recommended infection control steps.

  18. 22 CFR 96.50 - Placement and post-placement monitoring until final adoption in incoming cases.

    Science.gov (United States)

    2010-04-01

    ... qualified escorts, if used, and, if possible, in the company of the prospective adoptive parent(s). (b) In... greater. (c) When a placement for adoption is in crisis in the post-placement phase, the agency or person... resolving the crisis and the placement is disrupted, the agency or person assuming custody of the child...

  19. Simplified Surgical Placement of Tenckhoff Catheter under Local Anesthesia: The Dammam Central Hospital Experience

    Directory of Open Access Journals (Sweden)

    Youmbissi T

    2001-01-01

    Full Text Available Many methods are used for the placement of Tenckhoff catheters. Eighteen consecutive Tenckhoff catheters were placed under local anesthesia through a mini laparotomy with a reduced operating team. There were only three total catheter failures. Complications were infrequent and operating time was less than one hour on average. This simple procedure should be a part of the training program of all junior surgeons and nephrologists.

  20. A format for phylogenetic placements.

    Directory of Open Access Journals (Sweden)

    Frederick A Matsen

    Full Text Available We have developed a unified format for phylogenetic placements, that is, mappings of environmental sequence data (e.g., short reads into a phylogenetic tree. We are motivated to do so by the growing number of tools for computing and post-processing phylogenetic placements, and the lack of an established standard for storing them. The format is lightweight, versatile, extensible, and is based on the JSON format, which can be parsed by most modern programming languages. Our format is already implemented in several tools for computing and post-processing parsimony- and likelihood-based phylogenetic placements and has worked well in practice. We believe that establishing a standard format for analyzing read placements at this early stage will lead to a more efficient development of powerful and portable post-analysis tools for the growing applications of phylogenetic placement.

  1. Intramuscular ketamine to facilitate pediatric central vascular access.

    Science.gov (United States)

    Denmark, T Kent; Hargrove, Jenny R; Brown, Lance

    2004-07-01

    Obtaining prompt vascular access in young children presenting to the emergency department (ED) is frequently both necessary and technically challenging. The objective of our study was to describe our experience using intramuscular (IM) ketamine to facilitate the placement of central venous catheters in children presenting to our ED needing vascular access in a timely fashion. We performed a retrospective medical record review of all pediatric patients central venous catheter facilitated by the use of IM ketamine. Eleven children met our inclusion criteria. Most of the children were young and medically complicated. The children ranged in age from 6 months to 8 years. The only complication identified was vomiting experienced by an 8-year-old boy. Emergency physicians successfully obtained central venous access in all subjects in the case series. The use of IM ketamine to facilitate the placement of central venous catheters in children who do not have peripheral venous access appears to be helpful. Emergency physicians may find it useful to be familiar with this use of IM ketamine.

  2. Antiseptic barrier cap effective in reducing central line-associated bloodstream infections: A systematic review and meta-analysis.

    Science.gov (United States)

    Voor In 't Holt, Anne F; Helder, Onno K; Vos, Margreet C; Schafthuizen, Laura; Sülz, Sandra; van den Hoogen, Agnes; Ista, Erwin

    2017-04-01

    Microorganisms can intraluminally access a central venous catheter via the catheter hub. The catheter hub should be appropriately disinfected to prevent central line-associated bloodstream infections (CLABSIs). However, compliance with the time-consuming manual disinfection process is low. An alternative is the use of an antiseptic barrier cap, which cleans the catheter hub by continuous passive disinfection. To compare the effects of antiseptic barrier cap use and manual disinfection on the incidence of CLABSIs. Systematic review and meta-analysis. We systematically searched Embase, Medline Ovid, Web-of-science, CINAHL EBSCO, Cochrane Library, PubMed Publisher and Google Scholar until May 10, 2016. The primary outcome, reduction in CLABSIs per 1000 catheter-days, expressed as an incidence rate ratio (IRR), was analyzed with a random effects meta-analysis. Studies were included if 1) conducted in a hospital setting, 2) used antiseptic barrier caps on hubs of central lines with access to the bloodstream and 3) reported the number of CLABSIs per 1000 catheter-days when using the barrier cap and when using manual disinfection. A total of 1537 articles were identified as potentially relevant and after exclusion of duplicates, 953 articles were screened based on title and abstract; 18 articles were read full text. Eventually, nine studies were included in the systematic review, and seven of these nine in the random effects meta-analysis. The pooled IRR showed that use of the antiseptic barrier cap was effective in reducing CLABSIs (IRR=0.59, 95% CI=0.45-0.77, Pantiseptic barrier cap is associated with a lower incidence CLABSIs and is an intervention worth adding to central-line maintenance bundles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. Central stars of planetary nebulae. II. New OB-type and emission-line stars

    Science.gov (United States)

    Weidmann, W. A.; Gamen, R.

    2011-07-01

    Context. There are more than 3000 confirmed and probably known Galactic planetary nebulae (PNe), but central star spectroscopic information is available for only 13% of them. Aims: We have undertaken a spectroscopic survey of the central stars in PNe to identify their spectral types. Methods: We performed spectroscopic observations at low resolution with the 2-m telescope at CASLEO, Argentina. Results: We present the spectra of 46 central stars of PNe, most of them are OB-type and emission-line stars. Based on data collected at the Complejo Astronómico El Leoncito (CASLEO), which is operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina y Universidades Nacionales de La Plata, Córdoba y San Juan, Argentina.The reduced spectra (FITS files) are available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/531/A172

  5. ESL Placement and Schools

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2010-01-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn. PMID:20617111

  6. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  7. ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA

    Directory of Open Access Journals (Sweden)

    Darminto Pujotomo

    2012-02-01

    Full Text Available PT. Coca-Cola Bottling Indonesia (CCBI Central Java merupakan salah satu perusahaan produsen minuman ringan yang terkemuka di Indonesia, dengan dua jenis kelompok produk yang dihasilkan yaitu minuman karbonasi/Carbonated Soft Drink (Coca-Cola, Sprite, dan Fanta dan non-karbonasi (Frestea dan Ades. Dalam usaha untuk mempertahankan mutu dan meningkatkan produktifitas, salah satu faktor yang harus diperhatikan adalah masalah perawatan fasilitas/mesin produksi.  Makalah ini membahas mengenai penyebab dan akibat yang ditimbulkan oleh breakdown mesin terjadi pada Line 8/Carbonated Soft Drink, khususnya pada conveyor, filler machine, dan bottle washer machine. Untuk mendapatkan mesin yang dapat terjaga keterandalannya dibutuhkan suatu konsep yang baik. Total Productive Maintenance (TPM merupakan sebuah konsep yang baik untuk merealisasikan hal tersebut. Konsep ini, selain melibatkan semua personil dalam perusahaan, juga bertujuan untuk merawat semua fasilitas produksi yang dimiliki perusahaan.Data yang digunakan merupakan data breakdown conveyor, filler machine, dan bottle washer machine dari ME Monthly Report PT.CCBI selama bulan Januari-Desember 2005 khususnya line 8. Selain itu makalah ini juga membahas performance maintenance PT. Coca-Cola Bottling Indonesia-Central Java, dengan memperhitungkan nilai Mean Time Beetwen Failure (MTBF, Mean Time To Repair (MTTR, serta Availability mesin, dengan menggunakan data record Line 8 selama bulan Mei 2006 sampai bulan Juli 2006. Sehingga nantinya akan diketahui informasi keadaan aktual dari perusahaan tentang sistem perawatannya, khususnya pada Line 8/Carbonated Soft Drink apakah baik atau buruk. Kata kunci : Total Production Maintenance, Conveyor, Filler Machine, Bottle Washer Machine, Performance Maintenance   PT. Coca-Cola Bottling Indonesia (CCBI-Central Java represent one of notable light beverage producer company in Indonesia, with two product group type yielded is carbonated beverage/Carbonated Soft

  8. 75 FR 75205 - R.J. Corman Railroad Company/Central Kentucky Lines, LLC-Trackage Rights Exemption-CSX...

    Science.gov (United States)

    2010-12-02

    ... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. FD 35442] R.J. Corman... agreed to grant limited overhead trackage rights to R.J. Corman Railroad Company/Central Kentucky Lines... RJCC actually obtained these trackage rights in 2005.\\3\\ In the original notices, R.J. Corman Railroad...

  9. Efficiency and economic benefits of skipjack pole and line (huhate) in central Moluccas, Indonesia

    Science.gov (United States)

    Siahainenia, Stevanus M.; Hiariey, Johanis; Baskoro, Mulyono S.; Waeleruny, Wellem

    2017-10-01

    Excess fishing capacity is a crucial problem in marine capture fisheries. This phenomenon needed to be investigated regarding sustainability and development of the fishery. This research was aimed at analyzing technical efficiency (TE) and computing financial aspects of the skipjack pole and line. Primary data were collected from the owners of the fishing units at the different size of gross boat tonnage (GT), while secondary data were gathered from official publications relating to this research. Data envelopment analysis (DEA) approach was applied to estimate technical efficiency whereas a selected financial analysis was utilized to calculate economic benefits of the skipjack pole and line business. The fishing units with a size of 26-30 GT provided a higher TE value, and also achieved larger economic benefit values than that of the other fishing units. The empirical results indicate that skipjack pole and line in the size of 26-30 GT is a good fishing gear for the business development in central Moluccas.

  10. Profundidade de instalação da linha de gotejadores em tomateiro para processamento industrial Drip line placement depth for processing tomatoes crop

    Directory of Open Access Journals (Sweden)

    Waldir A. Marouelli

    2002-06-01

    Full Text Available Avaliou-se a resposta do tomateiro para processamento industrial, irrigado por gotejamento, a diferentes profundidades de instalação da linha lateral de gotejadores (0; 20 e 40 cm. Um tratamento irrigado por aspersão foi utilizado como controle. O experimento foi conduzido na Embrapa Hortaliças, nas condições edafoclimáticas da região de cerrados do Brasil Central. Maior crescimento vegetativo de plantas foi observado nos tratamentos irrigados por aspersão e gotejamento superficial, enquanto que menor crescimento ocorreu no gotejamento a 40 cm. A produtividade comercial do tratamento irrigado por gotejamento superficial (124 t.ha-1 foi 32% maior que no tratamento por gotejamento subterrâneo a 40 cm, 15% maior que no tratamento irrigado por aspersão, não diferindo (p>0,05 do tratamento por gotejamento a 20 cm. Incrementos de produtividade foram devidos, principalmente, ao maior número de frutos por planta, uma vez que o estande final e a massa média de frutos não foram afetados pelos tratamentos. A incidência de frutos podres na irrigação por aspersão foi 112 e 453% maior que nos tratamentos irrigados por gotejamento superficial e subterrâneo, respectivamente.A field experiment was carried out at Embrapa Hortaliças under soil and climate conditions of Central Brazil "cerrado" region, aiming to evaluate the response of drip-irrigated processing tomatoes to different drip line placement depths (0; 20 and 40 cm. A control treatment was irrigated by sprinkle system. Larger plant vegetative growth was observed for the sprinkle and surface drip treatments, while smaller growth occurred for the 40 cm-depth drip treatment. Marketable yield of the surface drip irrigated treatment (124 t.ha-1 was 32% larger than the 40 cm-depth drip treatment, 15% larger than the sprinkle treatment, but did not differ (p>0,05 from the 20 cm-depth drip treatment. Yield increments were basically due to a larger number of fruits per plant, since final

  11. Humanitarian engineering placements in our own communities

    Science.gov (United States)

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-05-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.

  12. Leadership line care rounds: Application of the engage, educate, execute, and evaluate improvement model for the prevention of central line-associated bloodstream infections in children with cancer.

    Science.gov (United States)

    Owings, Angie; Graves, JoBeth; Johnson, Sherry; Gilliam, Craig; Gipson, Mike; Hakim, Hana

    2018-02-01

    To prevent central line-associated bloodstream infections (CLABSIs), leadership line care rounds (LLCRs) used the engage, educate, execute, and evaluate improvement model to audit compliance, identify barriers and opportunities, empower patients and families, and engage leadership. Findings of excellence and improvement opportunities were communicated to unit staff and managers. LLCRs contributed to compliance with CLABSI prevention interventions. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Establishment of an agamid cell line and isolation of adenoviruses from central bearded dragons (Pogona vitticeps).

    Science.gov (United States)

    Ball, Inna; Hoferer, Marc; Marschang, Rachel E

    2014-03-01

    A cell line was established from whole 6-8-week-old central bearded dragon (Pogona vitticeps) embryos. Cells were mid-sized and showed an elongated and polymorphic form. The cell line grew in a monolayer and has been serially passaged for 17 passages at time of publication. This cell line has been used with samples from adenovirus polymerase chain reaction (PCR)-positive bearded dragons, and 2 virus isolates have been obtained so far. The isolates show a clear cytopathic effect in inoculated cells. Both virus isolates have been serially passaged on this cell line, and have been identified by PCR amplification and sequencing of a portion of the DNA-dependent DNA polymerase gene and show 100% nucleotide identity to the corresponding region of an agamid adenovirus. Electron microscopic examination of supernatant from infected cells demonstrated the presence of nonenveloped particles, with a diameter of approximately 80 nm in both virus isolates.

  14. Modern technology for landfill waste placement

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, D.L. [Landfill Service Corp., Apalachin, NY (United States)

    1995-12-31

    The City of Albany, New York, together with the principals of Landfill Service Corporation, proposed in November 1991 to demonstrate the successful practice of biostabilized solid waste placement in the newly constructed, double composite lined Interim Landfill located at Rapp Road in the City of Albany. This is a small facility, only 12 acres in area, which is immediately adjacent to residential neighbors. Significant advancements have been made for the control of environmental factors (odors, vectors, litter) while successfully achieving waste stabilization and air space conservations goals. Also, the procedure consumes a significant quantity of landfill leachate. The benefits of this practice include a dramatic improvement in the orderlines of waste placement with significant reduction of windblown dust and litter. The biostabilization process also reduces the presence of typical landfill vectors such as flies, crows, seagulls and rodents. All of these factors can pose serious problems for nearby residents to the City of Albany`s Interim landfill site. The physically and biologically uniform character of the stabilized waste mass can result in more uniform future landfill settlement and gas production properties. This can allow for more accurate prediction of postclosure conditions and reduction or elimination of remedial costs attendant to post closure gross differential settlement. Recent research in Europe indicates that aerobic pretreatment of waste also reduces contaminant loading of leachate.

  15. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  16. Gamification and Microlearning for Engagement With Quality Improvement (GAMEQI): A Bundled Digital Intervention for the Prevention of Central Line-Associated Bloodstream Infection.

    Science.gov (United States)

    Orwoll, Benjamin; Diane, Shelley; Henry, Duncan; Tsang, Lisa; Chu, Kristin; Meer, Carrie; Hartman, Kevin; Roy-Burman, Arup

    Central line-associated bloodstream infections (CLABSIs) cause major patient harm, preventable through attention to line care best practice standards. The objective was to determine if a digital self-assessment application (CLABSI App), bundling line care best practices with social gamification and in-context microlearning, could engage nurses in CLABSI prevention. Nurses caring for children with indwelling central venous catheters in 3 high-risk units were eligible to participate. All other units served as controls. The intervention was a 12-month nonrandomized quality improvement study of CLABSI App implementation with interunit competitions. Compared to the preceding year, the intervention group (9886 line days) CLABSI rate decreased by 48% ( P = .03). Controls (7879 line days) did not change significantly. In all, 105 unique intervention group nurses completed 673 self-assessments. Competitions were associated with increased engagement as measured by self-assessments and unique participants. This model could be extended to other health care-associated infections, and more broadly to process improvement within and across health care systems.

  17. Best Practices for Setting Placement Cut Scores in Postsecondary Education. An NCPR Working Paper

    Science.gov (United States)

    Morgan, Deanna L.

    2010-01-01

    Cut scores are used in a variety of circumstances to aid in decision making through the establishment of a clear cut line between adjacent categories. Community colleges regularly use cut scores on placement tests to decide the appropriate course for each beginning student: the first college-level course or a developmental course, depending on…

  18. Evaluating the effect placement capacitor and distributed photovoltaic generation for power system losses minimization in radial distribution system

    Science.gov (United States)

    Rahman, Yuli Asmi; Manjang, Salama; Yusran, Ilham, Amil Ahmad

    2018-03-01

    Power loss minimization have many advantagess to the distribution system radial among others reduction of power flow in feeder lines, freeing stress on feeder loading, deterrence of power procurement from the grid and also the cost of loss compensating instruments. This paper, presents capacitor and photovoltaic (PV) placement as alternative means to decrease power system losses. The paper aims to evaluate the best alternative for decreasing power system losses and improving voltage profile in the radial distribution system. To achieve the objectives of paper, they are used three cases tested by Electric Transient and Analysis Program (ETAP) simulation. Firstly, it performs simulation of placement capacitor. Secondly, simulated placement of PV. Lastly, it runs simulation of placement capacitor and PV simultaneously. The simulations were validated using the IEEE 34-bus test system. As a result, they proved that the installation of capacitor and PV integration simultaneously leading to voltage profile correction and power losses minimization significantly.

  19. Placement of a Retrievable Guenther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis

    International Nuclear Information System (INIS)

    Nadkarni, Sanjay; Macdonald, Sumaira; Cleveland, Trevor J.; Gaines, Peter A.

    2002-01-01

    A retrievable Guenther Tulip caval filter(William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances

  20. [Thrombosis and obstruction associated with central venous lines. Incidence and risk factors].

    Science.gov (United States)

    Vivanco Allende, A; Rey Galán, C; Rodríguez de la Rúa, M V; Alvarez García, F; Medina Villanueva, A; Concha Torre, A; Mayordomo Colunga, J; Martínez Camblor, P

    2013-09-01

    To analyse the incidence of thrombosis and obstruction associated with central venous lines (CVL) inserted in critically ill children, and to determine their risk factors. Prospective observational study in a Pediatric Intensive Care Unit in a University Hospital. An analysis was made of 825 CVL placed in 546 patients. Age, gender, weight, type of catheter (lines, size, and brand), final location of the catheter, mechanical ventilation, type of sedation and analgesia used, initial failure by the doctor to perform CVL catheterization, number of attempts, CVL indication, admission diagnosis, emergency or scheduled procedure, and delayed mechanical complications (DMC). Risk factors for these complications were determined by a multiple regression analysis. A total of 52 cases of DMC, 42 cases of obstruction, and 10 of thrombosis were registered. Obstruction and thrombosis rates were 4.96 and 1.18 per 100 CVL, respectively. The only risk factor independently linked to obstruction was the duration of the CVL (OR 1.05; 95% CI; 1.00-1.10). The number of lines with thrombosis (OR 4.88; 95% CI; 1.26-18.0), as well as parenteral nutrition (OR 4.17; 95% CI; 1.06-16.31) was statistically significant according to bivariate analysis. However, no risk factors for thrombosis were found in the multivariate analysis. Obstruction and thrombosis of CVL inserted in a Pediatric Intensive Care Unit are relatively common complications. CVL duration is an independent risk factor for any line obstruction. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  1. Stepwise introduction of the 'Best Care Always' central-line-associated bloodstream infection prevention bundle in a network of South African hospitals.

    Science.gov (United States)

    Richards, G A; Brink, A J; Messina, A P; Feldman, C; Swart, K; van den Bergh, D

    2017-09-01

    Healthcare-associated infection (HCAI) remains a major international problem. The 'Best Care Always!' (BCA) campaign was launched in South Africa to reduce preventable HCAI, including central-line-associated bloodstream infection (CLABSI). The intervention took place in 43 Netcare Private Hospitals, increasing later to 49 with 958 intensive care units (ICUs) and 439 high-care (HC) beds and 1207 ICUs and 493 HC beds, respectively. Phase 1, April 2010 to March 2011, ICU infection prevention and control (IPC) nurse-driven change: commitment from management and doctors and training of IPC nurses. Bundle compliance and infections per 1000 central-line-days were incorporated as standard IPC measures and captured monthly. Phase 2, April 2011 to March 2012, breakthrough collaborative method: multiple regional learning sessions for nursing leaders, IPC nurses and unit managers. Phase 3, April 2012 to May 2016: sustained goal-setting, benchmarks, ongoing audits. A total of 1,119,558 central-line-days were recorded. Bundle compliance improved significantly from a mean of 73.1% [standard deviation (SD): 11.2; range: 40.6-81.7%] in Phase 1 to a mean of 90.5% (SD: 4.7; range: 76.5-97.2%) in Phase 3 (P = 0.0004). The CLABSI rate declined significantly from a mean of 3.55 (SD: 0.82; range: 2.54-5.78) per 1000 central-line-days in Phase 1 to a mean of 0.13 (SD: 0.09; range: 0-0.33) (P hospitals resulted in significant decreases in CLABSI. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  3. Implementing a multifaceted intervention to decrease central line-associated bloodstream infections in SEHA (Abu Dhabi Health Services Company) intensive care units: the Abu Dhabi experience.

    Science.gov (United States)

    Latif, Asad; Kelly, Bernadette; Edrees, Hanan; Kent, Paula S; Weaver, Sallie J; Jovanovic, Branislava; Attallah, Hadeel; de Grouchy, Kristin K; Al-Obaidli, Ali; Goeschel, Christine A; Berenholtz, Sean M

    2015-07-01

    OBJECTIVE To determine whether implementation of a multifaceted intervention would significantly reduce the incidence of central line-associated bloodstream infections. DESIGN Prospective cohort collaborative. SETTING AND PARTICIPANTS Intensive care units of the Abu Dhabi Health Services Company hospitals in the Emirate of Abu Dhabi. INTERVENTIONS A bundled intervention consisting of 3 components was implemented as part of the program. It consisted of a multifaceted approach that targeted clinician use of evidence-based infection prevention recommendations, tools that supported the identification of local barriers to these practices, and implementation ideas to help ensure patients received the practices. Comprehensive unit-based safety teams were created to improve safety culture and teamwork. Finally, the measurement and feedback of monthly infection rate data to safety teams, senior leaders, and staff in participating intensive care units was encouraged. The main outcome measure was the quarterly rate of central line-associated bloodstream infections. RESULTS Eighteen intensive care units from 7 hospitals in Abu Dhabi implemented the program and achieved an overall 38% reduction in their central line-associated bloodstream infection rate, adjusted at the hospital and unit level. The number of units with a quarterly central line-associated bloodstream infection rate of less than 1 infection per 1,000 catheter-days increased by almost 40% between the baseline and postintervention periods. CONCLUSION A significant reduction in the global morbidity and mortality associated with central line-associated bloodstream infections is possible across intensive care units in disparate settings using a multifaceted intervention.

  4. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    Science.gov (United States)

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  5. SPOT-A SENSOR PLACEMENT OPTIMIZATION TOOL FOR ...

    Science.gov (United States)

    journal article This paper presents SPOT, a Sensor Placement Optimization Tool. SPOT provides a toolkit that facilitates research in sensor placement optimization and enables the practical application of sensor placement solvers to real-world CWS design applications. This paper provides an overview of SPOT’s key features, and then illustrates how this tool can be flexibly applied to solve a variety of different types of sensor placement problems.

  6. Patients with Central Lines - What You Need to Know to Avoid a Bloodstream Infection PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2011-03-01

    This 60 second PSA is based on the March, 2011 CDC Vital Signs report which indicates bloodstream infections in patients with central lines are largely preventable when healthcare providers use CDC-recommended infection control steps.  Created: 3/1/2011 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/1/2011.

  7. Central and peripheral venous lines-associated blood stream infections in the critically ill surgical patients.

    Science.gov (United States)

    Ugas, Mohamed Ali; Cho, Hyongyu; Trilling, Gregory M; Tahir, Zainab; Raja, Humaera Farrukh; Ramadan, Sami; Jerjes, Waseem; Giannoudis, Peter V

    2012-09-04

    Critically ill surgical patients are always at increased risk of actual or potentially life-threatening health complications. Central/peripheral venous lines form a key part of their care. We review the current evidence on incidence of central and peripheral venous catheter-related bloodstream infections in critically ill surgical patients, and outline pathways for prevention and intervention. An extensive systematic electronic search was carried out on the relevant databases. Articles were considered suitable for inclusion if they investigated catheter colonisation and catheter-related bloodstream infection. Two independent reviewers engaged in selecting the appropriate articles in line with our protocol retrieved 8 articles published from 1999 to 2011. Outcomes on CVC colonisation and infections were investigated in six studies; four of which were prospective cohort studies, one prospective longitudinal study and one retrospective cohort study. Outcomes relating only to PICCs were reported in one prospective randomised trial. We identified only one study that compared CVC- and PICC-related complications in surgical intensive care units. Although our search protocol may not have yielded an exhaustive list we have identified a key deficiency in the literature, namely a paucity of studies investigating the incidence of CVC- and PICC-related bloodstream infection in exclusively critically ill surgical populations. In summary, the diverse definitions for the diagnosis of central and peripheral venous catheter-related bloodstream infections along with the vastly different sample size and extremely small PICC population size has, predictably, yielded inconsistent findings. Our current understanding is still limited; the studies we have identified do point us towards some tentative understanding that the CVC/PICC performance remains inconclusive.

  8. Importance of blood cultures from peripheral veins in pediatric patients with cancer and a central venous line

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Rutkjaer, Cecilie

    2015-01-01

    When an infection is suspected in a child with cancer and a central venous line (CVL), cultures are often only obtained from the CVL and not from a peripheral vein (PV). This study was undertaken to evaluate the importance of concomitant blood cultures from the CVL and a PV....

  9. Staple Line Reinforcement with Stitch in Laparoscopic Sleeve Gastrectomies. Is It Useful or Harmful?

    Science.gov (United States)

    Albanopoulos, Konstantinos; Tsamis, Dimitrios; Arapaki, Aggeliki; Kleidi, Eleftheria; Zografos, Georgios; Leandros, Emmanouil

    2015-07-01

    Reinforcement of the staple line in laparoscopic sleeve gastrectomy (LSG) is a practice that leads to less morbidity, but equivocal results have been reported in the literature. This is a prospective randomized study comparing two groups of patients who underwent LSG. In one group LSG was performed with a running absorbable suture placement at the staple line. In the other group the running suture was not placed. General data of the patients, as well as intraoperative and postoperative data, were gathered and statistically analyzed. Overall, 146 patients were subjected to LSG. In 84 patients a running suture was placed, and in 62 patients no suture was placed. No significant differences were found between the two groups in demographic data. No significant differences were found also in the intraoperative data, such as number of trocars, number and type of cartridges, drain placement, and operative time (45±21 versus 40±20 minutes, respectively; Prunning suture (9.5% versus 0.0%, respectively; P.05). After this randomized study, final conclusions about the efficacy of this running suture to the staple line cannot be made. To the contrary, problems seem to exist after such reinforcement of the staple line, such as hematomas. Dealing with possible leaks and hemorrhage of the staple line is also problematic after placement of the running suture.

  10. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories.

    Science.gov (United States)

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-11-17

    Objectives : The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform ( n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results : There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions : The results suggest interesting avenues for policy makers and service providers to improve

  11. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    Directory of Open Access Journals (Sweden)

    Sonia Hélie

    2017-11-01

    Full Text Available Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1 to examine trends in placement use and placement stability since the reform and (2 to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425. Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service

  12. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    Science.gov (United States)

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-01-01

    Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service providers to improve the

  13. Longitudinal development of number line estimation and mathematics performance in primary school children

    NARCIS (Netherlands)

    Friso-van den Bos, I.; Kroesbergen, E.H.; van Luit, J.E.H.; Xenidou-Dervou, I.; Jonkman, L.M.; van der Schoot, M.; van Lieshout, E.C.D.M.

    2015-01-01

    Children's ability to relate number to a continuous quantity abstraction visualized as a number line is widely accepted to be predictive of mathematics achievement. However, a debate has emerged with respect to how children's placements are distributed on this number line across development. In the

  14. Two-Phase Algorithm for Optimal Camera Placement

    Directory of Open Access Journals (Sweden)

    Jun-Woo Ahn

    2016-01-01

    Full Text Available As markers for visual sensor networks have become larger, interest in the optimal camera placement problem has continued to increase. The most featured solution for the optimal camera placement problem is based on binary integer programming (BIP. Due to the NP-hard characteristic of the optimal camera placement problem, however, it is difficult to find a solution for a complex, real-world problem using BIP. Many approximation algorithms have been developed to solve this problem. In this paper, a two-phase algorithm is proposed as an approximation algorithm based on BIP that can solve the optimal camera placement problem for a placement space larger than in current studies. This study solves the problem in three-dimensional space for a real-world structure.

  15. Mathematics Placement at the University of Illinois

    Science.gov (United States)

    Ahlgren Reddy, Alison; Harper, Marc

    2013-01-01

    Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…

  16. Product placement of computer games in cyberspace.

    Science.gov (United States)

    Yang, Heng-Li; Wang, Cheng-Shu

    2008-08-01

    Computer games are considered an emerging media and are even regarded as an advertising channel. By a three-phase experiment, this study investigated the advertising effectiveness of computer games for different product placement forms, product types, and their combinations. As the statistical results revealed, computer games are appropriate for placement advertising. Additionally, different product types and placement forms produced different advertising effectiveness. Optimum combinations of product types and placement forms existed. An advertisement design model is proposed for use in game design environments. Some suggestions are given for advertisers and game companies respectively.

  17. K.S. Micro-Implant Placement Guide

    OpenAIRE

    Sharma, K; Sangwan, A

    2014-01-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide sugge...

  18. Longitudinal development of number line estimation and mathematics performance in primary school children

    NARCIS (Netherlands)

    Friso - van den Bos, Ilona; Kroesbergen, Evelyn; van Luit, Hans; Xenidou-Dervou, Iro; Jonkman, Lisa M.; Van der Schoot, Menno; Van Lieshout, Ernest C. D. M.

    2015-01-01

    Children’s ability to relate number to a continuous quantity abstraction visualized as a number line is widely accepted to be predictive of mathematics achievement. However, a debate has emerged with respect to how children’s placements are distributed on this number line across development. In the

  19. Patients with Central Lines — What You Need to Know to Avoid a Bloodstream Infection

    Centers for Disease Control (CDC) Podcasts

    2011-03-01

    This podcast is based on the March, 2011 CDC Vital Signs report which indicates bloodstream infections in patients with central lines are largely preventable when healthcare providers use CDC-recommended infection control steps.  Created: 3/1/2011 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/1/2011.

  20. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  1. Increased central common drive to ankle plantar flexor and dorsiflexor muscles during visually guided gait

    DEFF Research Database (Denmark)

    Jensen, Peter; Jensen, Nicole Jacqueline; Terkildsen, Cecilie Ulbæk

    2018-01-01

    When we walk in a challenging environment, we use visual information to modify our gait and place our feet carefully on the ground. Here, we explored how central common drive to ankle muscles changes in relation to visually guided foot placement. Sixteen healthy adults aged 23 ± 5 years participa......When we walk in a challenging environment, we use visual information to modify our gait and place our feet carefully on the ground. Here, we explored how central common drive to ankle muscles changes in relation to visually guided foot placement. Sixteen healthy adults aged 23 ± 5 years...

  2. Planned and unplanned terminations of foster care placements in the Netherlands: Relationships with characteristics of foster children and foster placements

    NARCIS (Netherlands)

    van Rooij, F.; Maaskant, A.; Weijers, I.; Weijers, D.; Hermanns, J.

    2015-01-01

    This study examined the role of placement and child characteristics in the unplanned termination of foster placements. Data were used from 169 foster children aged 0 to 20. Results showed that 35% of all foster placement terminations were unplanned. Outcomes of logistic regression analyses

  3. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  4. A Cognitive Model of College Mathematics Placement

    Science.gov (United States)

    1989-08-01

    study focused on the precalculus -- calculus placement decision. The Cognitive model uses novel, or analysis level, placement test items in an attempt to...relative to the requirements of a precalculus course. Placement test scores may be partitioned to give analysis and non-analysis subtest scores which can...67 5.1.1 1989 Intercorrelations ....................................................................... 67 5.1.2 1989 Precalculus -Calculus

  5. The ATCA CABB Line Survey on Centaurus A: Properties of the Molecular Gas from the Dust Lanes to the Central Engine

    Science.gov (United States)

    Ott, Juergen; Koribalski, Baerbel; Henkel, Christian; Edwards, Philip; Norris, Ray; Meier, David; Feain, Ilana; Curran, Steve; Martin-Pintado, Jesus; Beelen, Alexandre; Aalto, Susanne; Combes, Francoise; Israel, Frank; Muller, Sebastien; Espada, Daniel; Guelin, Michel; Black, John Harry; V-Trung, Dinh; Impellizzeri, Caterina M. V.; Persson, Carina

    2011-10-01

    Centaurus A with its host NGC5128 is the most nearby radio galaxy. Its molecular spectrum exhibits three prominent features: a) gas that is located in the outer disk and dust lanes, b) absorption lines that are supposedly close to the central AGN, and c) gas in emission from the nucleus. We propose to perform an extensive line survey toward CenA using the exciting new capabilities of CABB. The broad basebands and narrow zoom bands of CABB are ideal to capture the full breath of the CenA spectral features. Our multi-band line observations will allow us to derive the exact physical conditions of each component as well as the chemistry involved. We will therefore obtain a comprehensive view of the physics imprinted on the molecular spectrum of a radio galaxy and its host, reaching from the central supermassive black hole, through the accretion region and the inner disk to the outer dust lanes.

  6. The benefits of a 5-day dysphagia intensive placement

    OpenAIRE

    Cocks, N.; Harding, C.; Pritchard, M.

    2014-01-01

    Finding practical dysphagia opportunities for students pre-qualification is challenging. Discussions with clinicians led to the development of a new placement model. The placement was just five days and had an accompanying workbook. The current study aimed to evaluate the benefits of the placement. Data were analysed from 40 students who attended an adult dysphagia placement and 13 who attended a paediatric dysphagia placement. Measures included a pre and post self-rating questionnaire, quali...

  7. Slope and Line of Best Fit: A Transfer of Knowledge Case Study

    Science.gov (United States)

    Nagle, Courtney; Casey, Stephanie; Moore-Russo, Deborah

    2017-01-01

    This paper brings together research on slope from mathematics education and research on line of best fit from statistics education by considering what knowledge of slope students transfer to a novel task involving determining the placement of an informal line of best fit. This study focuses on two students who transitioned from placing inaccurate…

  8. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  9. Optimal DG placement in deregulated electricity market

    International Nuclear Information System (INIS)

    Gautam, Durga; Mithulananthan, Nadarajah

    2007-01-01

    This paper presents two new methodologies for optimal placement of distributed generation (DG) in an optimal power flow (OPF) based wholesale electricity market. DG is assumed to participate in real time wholesale electricity market. The problem of optimal placement, including size, is formulated for two different objectives, namely, social welfare maximization and profit maximization. The candidate locations for DG placement are identified on the basis of locational marginal price (LMP). Obtained as lagrangian multiplier associated with active power flow equation for each node, LMP gives the short run marginal cost (SRMC) of electricity. Consumer payment, evaluated as a product of LMP and load at each load bus, is proposed as another ranking to identify candidate nodes for DG placement. The proposed rankings bridges engineering aspects of system operation and economic aspects of market operation and act as good indicators for the placement of DG, especially in a market environment. In order to provide a scenario of variety of DGs available in the market, several cost characteristics are assumed. For each DG cost characteristic, an optimal placement and size is identified for each of the objectives. The proposed methodology is tested in a modified IEEE 14 bus test system. (author)

  10. Support for Astronaut's View of Mexican/ Central American Fires and on-Line Earth Observations Training Manual

    Science.gov (United States)

    Kaminski, Charles F., Jr.

    1999-01-01

    A small project to compile remote sensing and in-site data to review the processes leading to the May 1998 Mexican/Central American fires was undertaken. A web page based on this project was assembled. The second project initiated involved an interactive and on-line program that will replace the paper version of the Earth Observations Preflight Training Manual. Technical support was provided to Prof. Marvin Glasser as needed.

  11. Strengthening the Three Lines of Defence in Terms of More Efficient Operational Risk Management in Central Banks

    Directory of Open Access Journals (Sweden)

    Luburić Radoica

    2017-01-01

    Full Text Available This paper is the result of the author`s many years of multidisciplinary research in the areas of quality management and operational risk management. The main focus of the research is aimed at strengthening the model of the “three lines of defence” in terms of more efficient management of operational risks - those that arise as a result of inadequate and unsuccessful processes and systems, human factors, as well as those that can appear as a result of external events. The strengthening of the three lines of defence model is brought about through the synergy of quality management principles, the principles of risk management, and the total quality management approach. In essence, the term strengthening may be interpreted as a process of continual improvement. Business operations based on the principles of quality management and risk management allow central banks to be able to continuously improve their overall business performance. The principles of quality management contain properly aligned and matched best solutions from current management theory and practice. Designed to work together - and this essentially means in a consistent, synchronized and synergistic manner, the principles are translated into a series of requirements and guidelines of international standards suitable for implementation. Through their synergy, the principles of quality management and risk management, as well as approaches to total quality management form a clear, applicable and sustainable paradigm of successful management of central banks. Incorporation of the principles of quality management in central bank systems and processes would significantly strengthen the three lines of defence, in terms of efficient operational risk management, which this paper aims to show in a clear and comprehensive manner. Although any central bank is a specific institution, all the principles of quality management and risk management can be applied to its operations. In addition to

  12. Product Placement and Brand Equity

    OpenAIRE

    Corniani, Margherita

    2003-01-01

    Product placement is the planned insertion of a brand within a movie, a fiction, etc. It can be used with other communication tools (i.e. advertising, sales promotions, etc.) in order to disseminate brand awareness and characterize brand image, developing brand equity. In global markets, product placement is particularly useful for improving brand equity of brands with a well established brand awareness.

  13. PEG Tube Placement

    Directory of Open Access Journals (Sweden)

    Saptarshi Biswas

    2014-01-01

    Full Text Available Percutaneous endoscopic gastrostomy (PEG has been used for providing enteral access to patients who require long-term enteral nutrition for years. Although generally considered safe, PEG tube placement can be associated with many immediate and delayed complications. Buried bumper syndrome (BBS is one of the uncommon and late complications of percutaneous endoscopic gastrostomy (PEG placement. It occurs when the internal bumper of the PEG tube erodes into the gastric wall and lodges itself between the gastric wall and skin. This can lead to a variety of additional complications such as wound infection, peritonitis, and necrotizing fasciitis. We present here a case of buried bumper syndrome which caused extensive necrosis of the anterior abdominal wall.

  14. Artificial Intelligence based technique for BTS placement

    Science.gov (United States)

    Alenoghena, C. O.; Emagbetere, J. O.; Aibinu, A. M.

    2013-12-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out.

  15. Artificial Intelligence based technique for BTS placement

    International Nuclear Information System (INIS)

    Alenoghena, C O; Emagbetere, J O; 1 Minna (Nigeria))" data-affiliation=" (Department of Telecommunications Engineering, Federal University of Techn.1 Minna (Nigeria))" >Aibinu, A M

    2013-01-01

    The increase of the base transceiver station (BTS) in most urban areas can be traced to the drive by network providers to meet demand for coverage and capacity. In traditional network planning, the final decision of BTS placement is taken by a team of radio planners, this decision is not fool proof against regulatory requirements. In this paper, an intelligent based algorithm for optimal BTS site placement has been proposed. The proposed technique takes into consideration neighbour and regulation considerations objectively while determining cell site. The application will lead to a quantitatively unbiased evaluated decision making process in BTS placement. An experimental data of a 2km by 3km territory was simulated for testing the new algorithm, results obtained show a 100% performance of the neighbour constrained algorithm in BTS placement optimization. Results on the application of GA with neighbourhood constraint indicate that the choices of location can be unbiased and optimization of facility placement for network design can be carried out

  16. Dental hygiene student experiences in external placements in Australia.

    Science.gov (United States)

    Taylor, Jane A; Hayes, Melanie J; Wallace, Linda

    2012-05-01

    While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.

  17. Patterning control strategies for minimum edge placement error in logic devices

    Science.gov (United States)

    Mulkens, Jan; Hanna, Michael; Slachter, Bram; Tel, Wim; Kubis, Michael; Maslow, Mark; Spence, Chris; Timoshkov, Vadim

    2017-03-01

    In this paper we discuss the edge placement error (EPE) for multi-patterning semiconductor manufacturing. In a multi-patterning scheme the creation of the final pattern is the result of a sequence of lithography and etching steps, and consequently the contour of the final pattern contains error sources of the different process steps. We describe the fidelity of the final pattern in terms of EPE, which is defined as the relative displacement of the edges of two features from their intended target position. We discuss our holistic patterning optimization approach to understand and minimize the EPE of the final pattern. As an experimental test vehicle we use the 7-nm logic device patterning process flow as developed by IMEC. This patterning process is based on Self-Aligned-Quadruple-Patterning (SAQP) using ArF lithography, combined with line cut exposures using EUV lithography. The computational metrology method to determine EPE is explained. It will be shown that ArF to EUV overlay, CDU from the individual process steps, and local CD and placement of the individual pattern features, are the important contributors. Based on the error budget, we developed an optimization strategy for each individual step and for the final pattern. Solutions include overlay and CD metrology based on angle resolved scatterometry, scanner actuator control to enable high order overlay corrections and computational lithography optimization to minimize imaging induced pattern placement errors of devices and metrology targets.

  18. A linear programming approach for placement of applicants to academic programs.

    Science.gov (United States)

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.

  19. Immediate placement of endosseous implants into the extraction sockets.

    Science.gov (United States)

    Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu

    2015-04-01

    Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  20. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  1. The Effects of Direction of Exertion, Path, and Load Placement in Nursing Cart Pushing and Pulling Tasks: An Electromyographical Study.

    Science.gov (United States)

    Kao, Huei Chu; Lin, Chiuhsiang Joe; Lee, Yung Hui; Chen, Su Huang

    2015-01-01

    The purpose of this study was to explore the effects of direction of exertion (DOE) (pushing, pulling), path (walking in a straight line, turning left, walking uphill), and load placement (LP) (the 18 blocks were indicated by X, Y and Z axis; there were 3 levels on the X axis, 2 levels on the Y axis, and 3 levels on the Z axis) on muscle activity and ratings of perceived exertion in nursing cart pushing and pulling tasks. Ten participants who were female students and not experienced nurses were recruited to participate in the experiment. Each participant performed 108 experimental trials in the study, consisting of 2 directions of exertion (push and pull), 3 paths, and 18 load placements (indicated by X, Y and Z axes). A 23kg load was placed into one load placement. The dependent variables were electromyographic (EMG) data of four muscles collected bilaterally as follows: Left (L) and right (R) trapezius (TR), flexor digitorum superficialis (FDS), extensor digitorum (ED), and erector spinae (ES) and subjective ratings of perceived exertion (RPE). Split-split-plot ANOVA was conducted to analyze significant differences between DOE, path, and LP in the EMG and RPE data. Pulling cart tasks produced a significantly higher activation of the muscles (RTR:54.4%, LTR:50.3%, LFDS:57.0%, LED:63.4%, RES:40.7%, LES:36.7%) than pushing cart tasks (RTR:42.4%, LTR:35.1%, LFDS:32.3%, LED:55.1%, RES:33.3%, LES:32.1%). A significantly greater perceived exertion was found in pulling cart tasks than pushing cart tasks. Significantly higher activation of all muscles and perceived exertion were observed for walking uphill than walking in a straight line and turning left. Significantly lower muscle activity of all muscles and subject ratings were observed for the central position on the X axis, the bottom position on the Y axis, and the posterior position on the Z axis. These findings suggest that nursing staff should adopt forward pushing when moving a nursing cart, instead of backward

  2. Peculiarities of product placement in Lithuanian movies

    OpenAIRE

    Pilelienė, Lina; Jurgilaitė, Sigita

    2013-01-01

    The scientific problem analysed in the article is formulates as follows: how product placement is used in Lithuanian movies. The object of the article is product placement in Lithuanian movies, and the aim is to analyse the peculiarities of product placement in Lithuanian movies. Following methods were used to reveal the problem and reach the aim. Theoretical analysis of scientific literature was provided to construct the framework for the research. The analysis of current usage of product pl...

  3. Immediate placement of endosseous implants into the extraction sockets

    Directory of Open Access Journals (Sweden)

    Vijay Ebenezer

    2015-01-01

    Full Text Available Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  4. Avaliação das práticas de adesão à higienização das mãos relacionadas com linhas vasculares em uma Unidade de Terapia Intensiva | Evaluation of hand hygiene practices related to placement of intravascular lines in an intensive care unit

    Directory of Open Access Journals (Sweden)

    Francisca Jane Gomes de Oliveira

    2015-11-01

    Full Text Available O estudo objetivou avaliar a conformidade e não conformidade das práticas de adesão à higienização das mãos com linhas vasculares na prevenção de infecção de corrente sanguínea relacionada ao cateter venoso central de curta permanência. Trata-se de um estudo observacional, com abordagem quantitativa. A casuística baseou-se em 892 avaliações, realizadas através da observação direta, utilizando o Manual de Avaliação da Qualidade de Práticas de Controle de Infecção Hospitalar da Secretaria de Estado da Saúde de São Paulo. Os resultados mostraram que as práticas relacionadas à higienização das mãos apresentaram índice de conformidade geral nulo, evidenciando baixos índices de conformidade individual, principalmente no que se refere à prática de higiene das mãos antes e após a troca do sistema de infusão, apresentando o menor índice de conformidade de todas as práticas observadas (10,3%. Já a prática relacionada à higienização das mãos antes e após a coleta de sangue apresenta melhor índice de conformidade individual (36,1%. Existe a necessidade de elaborar estratégias que assegurem a adesão das práticas de controle e prevenção de infecção de corrente sanguínea relacionada ao cateter venoso central através de aderência ao processo de higienização das mãos, bem como instituir avaliações periódicas das condições de trabalho, no sentido de elevar os índices de conformidade. ============================================= The study aimed to evaluate the compliance and non-compliance of the intensive care unit staff with regard to hand hygiene practices when placing intravascular lines to prevent bloodstream infections related to central venous catheter placement. This was an observational study with a quantitative approach. The study was based on 892 reviews obtained through direct observation using the Manual of Quality Evaluation of Hospital Infection Control Practices of the State

  5. Automated Fiber Placement of Advanced Materials (Preprint)

    National Research Council Canada - National Science Library

    Benson, Vernon M; Arnold, Jonahira

    2006-01-01

    .... ATK has been working with the Air Force Research Laboratory to foster improvements in the BMI materials and in the fiber placement processing techniques to achieve rates comparable to Epoxy placement rates...

  6. How do we facilitate international clinical placements for nursing students: A cross-sectional exploration of the structure, aims and objectives of placements.

    Science.gov (United States)

    Browne, Caroline A; Fetherston, Catherine M

    2018-07-01

    International clinical placements provide undergraduate students with a unique and complex clinical learning environment, to explore cultural awareness, experience different health care settings and achieve clinical competencies. Higher education institutions need to consider how to structure these placements to ensure appropriate and achievable aims and learning outcomes. In this study we described the structure, aims and learning outcomes associated with international clinical placement opportunities currently undertaken by Australian undergraduate nursing students in the Asia region. Forty eight percent (n = 18) of the institutions invited responded. Eight institutions met the inclusion criteria, one of which offered three placements in the region, resulting in 10 international placements for which data were provided. An online survey tool was used to collect data during August and September 2015 on international clinical placements conducted by the participating universities. Descriptive data on type and numbers of placements is presented, along with results from the content analysis conducted to explore data from open ended questions on learning aims and outcomes. One hundred students undertook 10 International Clinical Placements offered in the Asian region by eight universities. Variations across placements were found in the length of placement, the number of students participating, facilitator to student ratios and assessment techniques used. Five categories related to the aims of the programs were identified: 'becoming culturally aware through immersion', 'working with the community to promote health', 'understanding the role of nursing within the health care setting', 'translating theory into professional clinical practice', and 'developing relationships in international learning environments'. Four categories related to learning outcomes were identified: 'understanding healthcare and determinants of health', 'managing challenges', 'understanding the

  7. A new approach for optimum DG placement and sizing based on voltage stability maximization and minimization of power losses

    International Nuclear Information System (INIS)

    Aman, M.M.; Jasmon, G.B.; Bakar, A.H.A.; Mokhlis, H.

    2013-01-01

    Highlights: • A new algorithm is proposed for optimum DG placement and sizing.• I 2 R losses minimization and voltage stability maximization is considered in fitness function.• Bus voltage stability and line stability is considered in voltage stability maximization.• Multi-objective PSO is used to solve the problem.• Proposed method is compared with analytical and grid search algorithm. - Abstract: Distributed Generation (DG) placement on the basis of minimization of losses and maximization of system voltage stability are two different approaches, discussed in research. In the new proposed algorithm, a multi-objective approach is used to combine the both approaches together. Minimization of power losses and maximization of voltage stability due to finding weakest voltage bus as well as due to weakest link in the system are considered in the fitness function. Particle Swarm Optimization (PSO) algorithm is used in this paper to solve the multi-objective problem. This paper will also compare the propose method with existing DG placement methods. From results, the proposed method is found more advantageous than the previous work in terms of voltage profile improvement, maximization of system loadability, reduction in power system losses and maximization of bus and line voltage stability. The results are validated on 12-bus, 30-bus, 33-bus and 69-bus radial distribution networks and also discussed in detailed

  8. STUDENT PLACEMENT

    African Journals Online (AJOL)

    User

    students express lack of interest in the field they are placed, it ... be highly motivated to learn than students placed in a department ... the following research questions. Research Questions. •. Did the criteria used by Mekelle. University for placement of students into different departments affect the academic performance of ...

  9. C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

    International Nuclear Information System (INIS)

    Tam, Alda; Mohamed, Ashraf; Pfister, Marcus; Rohm, Esther; Wallace, Michael J.

    2009-01-01

    C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

  10. Teaching teamwork: an evaluation of an interprofessional training ward placement for health care students.

    Science.gov (United States)

    Morphet, Julia; Hood, Kerry; Cant, Robyn; Baulch, Julie; Gilbee, Alana; Sandry, Kate

    2014-01-01

    The establishment of interprofessional teamwork training in the preprofessional health care curriculum is a major challenge for teaching faculties. Interprofessional clinical placements offer an opportunity for teamwork education, as students in various professions can work and learn together. In this sequential, mixed-method study, focus group and survey techniques were used to evaluate students' educational experiences after 2-week ward-based interprofessional clinical placements. Forty-five senior nursing, medicine, and other health care students cared for patients in hospital wards under professional supervision, with nursing-medicine student "teams" leading care. Thirty-six students attended nine exit focus groups. Five central themes that emerged about training were student autonomy and workload, understanding of other professional roles, communication and shared knowledge, interprofessional teamwork/collaboration, and the "inner circle", or being part of the unit team. The learning environment was described as positive. In a postplacement satisfaction survey (n=38), students likewise rated the educational experience highly. In practicing teamwork and collaboration, students were able to rehearse their future professional role. We suggest that interprofessional clinical placements be regarded as an essential learning experience for senior preprofessional students. More work is needed to fully understand the effect of this interactive program on students' clinical learning and preparation for practice.

  11. Radiography students' perceptions of clinical placements - A Nigerian perspective

    International Nuclear Information System (INIS)

    Ogbu, S.O.I.

    2008-01-01

    Purpose: To assess undergraduate radiography student perception of clinical placements and to evaluate their clinical learning experiences. Methods: To evaluate student perception of clinical placements, a Likert-scale questionnaire was used to assess clinical practice, the practice-learning environment. One hundred and seventy-eight undergraduate [student] radiographers participated in the study. Results: The students indicated they had adequate and enjoyed their time on the clinical placement. They also indicated the qualified staff was supportive, friendly and approachable. The students were able to achieve their learning outcomes during the placement. However placement venues, according to the students, had inadequate learning resources. No radiographic/medical imaging research findings, whether locally generated or otherwise, were used in clinical practice. Conclusions: Clinical placements had adequate student support. It provided a pleasant learning experience for the students and it enhanced their skills. Staff was willing and available to assist learning. Nevertheless, the training institutions, professional body and clinical placement providers need to make an effort to address inadequate learning resources (e.g. IT, library, study rooms) as well as the non-utilization of radiographic/medical imaging research findings

  12. A qualitative study examining the preparedness of dental hygiene students for a service-learning placement in residential aged care.

    Science.gov (United States)

    Wallace, J P; Blinkhorn, A S; Blinkhorn, F A

    2017-02-01

    The aim of this qualitative study was to measure the effect of a specifically designed orientation re-enactment DVD used to facilitate dental hygiene students transition from the classroom to a Residential Aged Care Facility (RACF) service-learning placement with less personal anxiety and more confidence in their role during the placement. Final year students (n = 47) were randomly allocated to one of 17 RACFs on the NSW, Central Coast, Australia. All students were then randomly allocated to a two-group study with the active group assigned to view the DVD prior to their placement. Students who viewed the DVD were asked not to discuss the content with students who were assigned to the control group. Post-placement focus groups were organized, recorded and transcribed verbatim. Data were collated, analysed and unitized into emergent themes. Representative quotes are presented in the results. The study was informed by 4 years of previous quantitative and qualitative process evaluation of the RACF programme. Focus group discussions identified that those students who had seen the DVD reported a shorter timeframe to successfully transition from the classroom to the RACF and stated that the DVD provided them with a realistic expectation of the RACF environment and their role in the placement experience. The orientation DVD reduced student anxiety and improved student confidence in their role during the placement by providing a realistic orientation of the RACF environment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.

    Science.gov (United States)

    Jiao, Dechao; Huang, Kai; Zhu, Ming; Wu, Gang; Ren, Jianzhuang; Wang, Yanli; Han, Xinwei

    2017-01-01

    Whether unilateral or bilateral drainage should be performed for malignant hilar biliary obstruction remains a matter of debate. Although a Y-stent with a central wide-open mesh facilitates bilateral stent placement, it has its own limitations. This study aims to evaluate the feasibility and efficacy of a newly designed Y-configured bilateral self-expanding metallic stent (SEMS) for the treatment of hilar biliary obstruction. In this retrospective study, 14 consecutive patients with unresectable malignant hilar biliary obstruction (Bismuth type II or higher), who underwent placement of a newly designed Y-configured bilateral SEMS for hilar biliary obstruction from April 2013 to March 2015, were included into this study. Data on technical success, clinical success, stent patency, complications and patient survival were collected. Technical and clinical success was 100 and 92.9 %, respectively. Mean serum bilirubin level was significantly decreased 1 month after stent placement (P hilar biliary obstruction using port docking deployment.

  14. Entry-Level Placement Scores for the 1996-97 Academic Year.

    Science.gov (United States)

    Padron, Eduardo J.

    This memorandum reviews the implementation of new, state-mandated placement criteria at Florida's Miami-Dade Community College (MDCC). The first section focuses on placement criteria for degree-seeking students, indicating that MDCC uses scores on the Florida College Entry-Level Placement Test for making placement decisions in reading, writing,…

  15. Delayed bracket placement in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Chandra Wigati

    2008-12-01

    Full Text Available Background: Beside bracket position, the timing of bracket placement is one of the most essential in orthodontic treatment with fixed appliances. Even it seems simple the timing of bracket placement can be crucial and significantly influence the result of orthodontic treatment. However it is often found brackets are placed without complete understanding of its purpose and effects, which could be useless and even detrimental for the case. Purpose: The aim of this case report is to show that the timing of bracket placement could be different depending on the cases. Case: Five different cases are presented here with different timing of bracket placement. Case management: On these cases, brackets were placed on the upper arch first, on the lower arch first, or even only on some teeth first. Good and efficient orthodontic treatment results were achieved. Conclusion: For every orthodontic case, from the very beginning of treatment, bracket should be placed with the end result in mind. If brackets are correctly placed at a correct time, better treatment result could be achieved without unnecessary round tripping tooth movement.

  16. Factors Associated With Nursing Students' Resilience: Communication Skills Course, Use of Social Media and Satisfaction With Clinical Placement.

    Science.gov (United States)

    Sigalit, Warshawski; Sivia, Barnoy; Michal, Itzhaki

    The purpose of this study was to explore the (a) associations between students' personal and group resilience to their utilization of social networking platforms and formally taught communication skills, (b) students' personal and clinical characteristics that are related to personal and group resilience and the perceived helpfulness of communication course, and (c) factors that contribute to students' satisfaction with their clinical placement. Data were collected from 149 second year nursing students learning in a major university in the country of Israel with the use of a self-administered structured questionnaire. Students' satisfaction from their clinical placement was measured using 1 open-ended question, analyzed through qualitative methods. Results demonstrated positive correlations between students' use of social networking to their personal and group resilience (Pmedia use, religion, and clinical placement characteristics were related to resilience and to the perceived helpfulness of the communication course (P<.01). Students' satisfaction with their clinical placement was based primarily on the clinical instructors' personal and professional skills. In conclusion, social networking can and should be used as a learning tool to promote resilience among nursing students. Faculty and nurse managers should be aware of the central role of the clinical instructor and initiate collaborative and supporting initiatives. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. A Sea-of-Gates Style FPGA Placement Algorithm

    Directory of Open Access Journals (Sweden)

    Kalapi Roy

    1996-01-01

    Full Text Available Field Programmable Gate Arrays (FPGAs have a pre-defined chip boundary with fixed cell locations and routing resources. Placement objectives for flexible architectures (e.g., the standard cell design style such as minimization of chip area do not reflect the primary placement goals for FPGAs. For FPGAs, the layout tools must seek 100% routability within the architectural constraints. Routability and congestion estimates must be made directly based on the demand and availability of routing resources for detailed routing of the particular FPGA. We. present a hierarchical placement approach consisting of two phases: a global placement phase followed by a detailed placement phase. The global placement phase minimizes congestion estimates of the global routing regions and satisfies all constraints at a coarser level. The detailed placer seeks to maximize the routability of the FPGA by considering factors which cause congestion at the detailed routing level and to precisely satisfy all of the constraints. Despite having limited knowledge about the gate level architectural details, we have achieved a 90%reduction in the number of unrouted nets in comparison to an industrial tool (the only other tool developed specifically for this architecture.

  18. Confirmation of Essure placement using transvaginal ultrasound.

    Science.gov (United States)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent hysteroscopic sterilization using the Essure device between March 2005 and December 2007. Transvaginal ultrasound examination 12 weeks after uncomplicated successful bilateral placement or as indicated according to the transvaginal ultrasound protocol after 4 weeks, and hysterosalpingography (HSG) at 12 weeks to confirm correct placement of the device after 3 months. The rate of successful placement was 88.4% initially. In 164 women (15%), successful placement was confirmed at HSG according the protocol. In 9 patients (0.84%), incorrect position of the device was observed at HSG. The cumulative pregnancy rate after 18 months was 3.85 per thousand women. Transvaginal ultrasound should be the first diagnostic test used to confirm the adequacy of hysteroscopic Essure sterilization because it is minimally invasive, averts ionizing radiation, and does not decrease the effectiveness of the Essure procedure. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  19. Facilitating Industrial Placement in the Construction Engineering Curriculum

    DEFF Research Database (Denmark)

    Wandahl, Søren; Ussing, Lene Faber

    2016-01-01

    outset in the hypothesis that external effectiveness (industry readiness) is better in those modes of education that, at least in part, are based on the world of work itself, and several sources highlight the necessity of strong links between engineering education and industry. Hence, it becomes central......There is often a claim that there is a disconnection between theory and practice, which raises questions on student’s readiness for employment and the extent that higher education responds effectively to the evolving needs of the construction industry. Industrial placements schemes can facilitate...... student learning from construction practice whereby students can reflect on their learning experience at the university. The interplay between traditional engineering curriculum and the context-based learning is important for securing the right skills and competencies among the graduates. This paper takes...

  20. SU-F-T-320: Assessing Placement Error of Optically Stimulated Luminescent in Vivo Dosimeters Using Cone-Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Riegel, A; Klein, E [Northwell Health, Lake Success, NY (United States); Tariq, M; Gomez, C [Hofstra University, Hempstead, NY (United States)

    2016-06-15

    Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before daily image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.

  1. Brand placement prominence: good for memory! Bad for attitudes?

    NARCIS (Netherlands)

    van Reijmersdal, E.

    2009-01-01

    This paper presents two laws about the effects of brand placement on audience reactions. This article presents two laws about the effects of brand placement on audience reactions. Brand placement is the compensated inclusion of brands or brand identifiers within media programming. The first law

  2. How media factors affect audience responses to brand placement

    NARCIS (Netherlands)

    van Reijmersdal, E.; Smit, E.; Neijens, P.

    2010-01-01

    This study investigates the influence of media factors on brand placement effects in a real-life setting. Although many studies on brand placement have been conducted, insights into context effects on brand placement reactions are scarce. The impact of objective and subjective media context factors

  3. Impacted material placement plans

    International Nuclear Information System (INIS)

    Hickey, M.J.

    1997-01-01

    Impacted material placement plans (IMPP) are documents identifying the essential elements in placing remediation wastes into disposal facilities. Remediation wastes or impacted material(s) are those components used in the construction of the disposal facility exclusive of the liners and caps. The components might include soils, concrete, rubble, debris, and other regulatory approved materials. The IMPP provides the details necessary for interested parties to understand the management and construction practices at the disposal facility. The IMPP should identify the regulatory requirements from applicable DOE Orders, the ROD(s) (where a part of a CERCLA remedy), closure plans, or any other relevant agreements or regulations. Also, how the impacted material will be tracked should be described. Finally, detailed descriptions of what will be placed and how it will be placed should be included. The placement of impacted material into approved on-site disposal facilities (OSDF) is an integral part of gaining regulatory approval. To obtain this approval, a detailed plan (Impacted Material Placement Plan [IMPP]) was developed for the Fernald OSDF. The IMPP provides detailed information for the DOE, site generators, the stakeholders, regulatory community, and the construction subcontractor placing various types of impacted material within the disposal facility

  4. Do Work Placements Improve Final Year Academic Performance or Do High-Calibre Students Choose to Do Work Placements?

    Science.gov (United States)

    Jones, C. M.; Green, J. P.; Higson, H. E.

    2017-01-01

    This study investigates whether the completion of an optional sandwich work placement enhances student performance in final year examinations. Using Propensity Score Matching, our analysis departs from the literature by controlling for self-selection. Previous studies may have overestimated the impact of sandwich work placements on performance…

  5. Universal suprapubic approach for complete mesocolic excision and central vascular ligation using the da Vinci Xi® system: from cadaveric models to clinical cases.

    Science.gov (United States)

    Yeo, Shen Ann; Noh, Gyoung Tae; Han, Jeong Hee; Cheong, Chinock; Stein, Hubert; Kerdok, Amy; Min, Byung Soh

    2017-12-01

    There has been little enthusiasm for performing robotic colectomy for colon cancer in recent years due to multiple factors, one being that the previous robotic systems such as the da Vinci Si ® (dVSi) were poorly designed for multi-quadrant surgery. The new da Vinci Xi ® (dVXi) system enables colectomy with central mesocolic excision to be performed easily in a single docking procedure. We developed a universal port placement strategy to allow right and left hemicolectomies to be performed via a suprapubic approach and a Pfannensteil extraction site. This proof of concept paper describes the development and subsequent clinical application of this setup. After extensive training on the dVXi system concepts in collaboration with clinical development engineers, we developed a port placement strategy which was tested and adapted after performing experimental surgery in three cadaveric models. Subsequently our port placement was used for two clinical cases of suprapubic right and left hemicolectomy. With some modifications of port placements after the initial cadaveric colectomies, we have developed a potentially universal suprapubic port placement strategy for robotic colectomy with complete mesocolic excision and central vascular ligation using the dVXi robotic system. This port placement strategy was applied successfully in our first two clinical cases. Based on our cadaveric laboratory as well as our initial clinical application, the suprapubic port placement strategy for the dVXi system with its improved features over the dVSi can feasibly perform right and left hemicolectomy with complete mesocolic excision and central vascular ligation. Further studies will be required to establish efficacy as well as safety profile of these procedures.

  6. Central venous catheterization: comparison between interventional radiological procedure and blind surgical reocedure

    International Nuclear Information System (INIS)

    Song, Won Gyu; Jin, Gong Yong; Han, Young Min; Yu, He Chul

    2002-01-01

    To determine the usefulness and safety of radiological placement of a central venous catheter by prospectively comparing the results of interventional radiology and blind surgery. For placement of a central venous catheter, the blind surgical method was used in 78 cases (77 patients), and the interventional radiological method in 56 cases (54 patients). The male to female ratio was 66:68, and the patients' mean age was 48 (range, 18-80) years. A tunneled central venous catheter was used in 74 cases, and a chemoport in 60. We evaluated the success and duration of the procedures, the number of punctures required, and ensuing complications, comparing the results of the two methods. The success rates of the interventional radiological and the blind surgical procedure were 100% and 94.8%, respectively. The duration of central catheterization was 3-395 (mean, 120) day, that of chemoport was 160.9 days, and that of tunneled central venous catheter was 95.1 days. The mean number of punctures of the subclavian vein was 1.2 of interventional radiology, and 2.1 for blind surgery. The mean duration of the interventional radiology and the blind surgical procedure was, respectively, 30 and 40 minutes. The postprocedure complication rate was 27.6% (37 cases). Early complications occurred in nine cases (6.7%): where interventional radiology was used, there was one case of hematoma, and blind surgery gave rise to hematoma (n=2), pneumothorax (n=2), and early deviation of the catheter (n=4). Late complications occurred in 32 cases (23.9%). Interventional radiology involved infection (n=4), venous thrombosis (n=1), catheter displacement (n=2) and catheter obstruction (n=5), while the blind surgical procedure gave rise to infection (n=5), venous thrombosis (n=3), catheter displacement (n=4) and catheter obstruction (n=8). The success rate of interventional radiological placement of a central venous catheter was high and the complication rate was low. In comparison with the blind

  7. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    Science.gov (United States)

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  8. K.s. Micro-implant placement guide.

    Science.gov (United States)

    Sharma, K; Sangwan, A

    2014-09-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide suggested in this article is simple design and easy in fabrication, required minimal equipment for fabrication and does not disturb the existing appliance system, clearly located in the radiograph and the mini-screw can be easily inserted through the guide reducing the chance of implant misplacement.

  9. Placement education pedagogy as social participation: what are students really learning?

    Science.gov (United States)

    Kell, Clare

    2014-03-01

    This paper draws on empirical fieldwork data of naturally occurring UK physiotherapy placement education to make visible how education is actually carried out and suggest what students may be learning through their placement interactions. The data challenge everyone involved in placement education design and practice to consider the values and practices students are learning to perpetuate through placement education experiences. The researcher undertook an ethnomethodologically informed ethnographic observation of naturally occurring physiotherapy placement education in two UK NHS placement sites. This study adopted a social perspective of learning to focus on the minutiae of placement educator, student and patient interaction practices during student-present therapeutic activities. Two days of placement for each of six senior students were densely recorded in real-time focussing specifically on the verbal, kinesics and proxemics-based elements of the participants' interaction practices. Repeated cycles of data analysis suggested consistent practices irrespective of the placement, educators, students or patients. The data suggest that placement education is a powerful situated learning environment in which students see, experience and learn to reproduce the physiotherapy practices valued by the local placement. Consistently, placement educators and students co-produced patient-facing activities as spectacles of physiotherapy-as-science. In each setting, patients were used as person-absent audiovisual teaching aids from which students learnt to make a case for physiotherapy intervention. The paper challenges physiotherapists and other professions using work-placement education to look behind the rhetoric of their placement documentation and explore the reality of students' learning in the field. The UK-based physiotherapy profession may wish to consider further the possible implications of its self-definition as a 'science-based healthcare profession' on its in

  10. When an object appears unexpectedly: foot placement during obstacle circumvention in children and adults with Developmental Coordination Disorder.

    Science.gov (United States)

    Wilmut, K; Barnett, A L

    2017-10-01

    Adjustments to locomotion to avoid an obstacle require a change to the usual pattern of foot placement, i.e. changes to step length and/or step width. Previous studies have demonstrated a difficulty in individuals with Developmental Coordination Disorder (DCD) in controlling stability while both stepping over and while circumventing an obstacle. In a previous study, we have considered the way in which individuals with DCD prepare for the possibility of an obstacle appearing (Wilmut and Barnett in Exp Brain Res 235:1531-1340, 2017). Using a parallel data set from this same task on the same individuals, the aim of the current study was to investigate the exact nature of changes in foot placement during obstacle avoidance, as this was not clear from previous work. Children and adults aged from 7 to 34 years of age took part in the study. Forty-four met the criteria for a diagnosis of DCD and there were 44 typically developing (TD) age and gender-matched controls. Participants walked at a comfortable pace down an 11 m walkway; on 6 out of 36 trials a 'gate' closed across their pathway which required circumvention. These 6 'gate close' trials were analysed for this study. The number and magnitude of step length and step width adjustments were similar across the DCD and TD groups, however, the younger children (7-11 years) made a greater number of early adjustments compared to the older children and adults (12-34 years of age). In contrast the adults made a greater number of adjustments later in the movement compared to the children. In terms of foot placement adjustments a clear preference was seen across all participants to use adjustments which resulted in reducing step length, stepping away from the obstacle and a combination of these. Apart from subtle differences, the individuals with DCD make step placements to circumvent an obstacle in line with their peers. It is suggested that the choice of foot placement strategy in individuals with DCD, although in line

  11. A GRB and Broad-lined Type Ic Supernova from a Single Central Engine

    Science.gov (United States)

    Barnes, Jennifer; Duffell, Paul C.; Liu, Yuqian; Modjaz, Maryam; Bianco, Federica B.; Kasen, Daniel; MacFadyen, Andrew I.

    2018-06-01

    Unusually high velocities (≳0.1c) and correspondingly high kinetic energies have been observed in a subset of Type Ic supernovae (so-called “broad-lined Ic” supernovae; SNe Ic-BL), prompting a search for a central engine model capable of generating such energetic explosions. A clue to the explosion mechanism may lie in the fact that all supernovae that accompany long-duration gamma-ray bursts (GRBs) belong to the SN Ic-BL class. Using a combination of two-dimensional relativistic hydrodynamics and radiation transport calculations, we demonstrate that the central engine responsible for long GRBs can also trigger an SN Ic-BL. We find that a reasonable GRB engine injected into a stripped Wolf–Rayet progenitor produces a relativistic jet with energy ∼1051 erg, as well as an SN whose synthetic light curves and spectra are fully consistent with observed SNe Ic-BL during the photospheric phase. As a result of the jet’s asymmetric energy injection, the SN spectra and light curves depend on viewing angle. The impact of viewing angle on the spectrum is particularly pronounced at early times, while the viewing-angle dependence for the light curves (∼10% variation in bolometric luminosity) persists throughout the photospheric phase.

  12. Student nurses' experiences of community-based practice placement learning: a qualitative exploration.

    Science.gov (United States)

    Baglin, M R; Rugg, Sue

    2010-05-01

    United Kingdom (UK) health policy has adopted an increasing community and primary care focus over recent years (Department of Health, 1997; Department of Health, 1999. Making a Difference: Strengthening the Nursing, Midwifery and Health Visitor Contribution to Health and Health Care. Department of Health, London; Department of Health, 2004. The NHS Knowledge and Skills Framework (NHS KSF). Department of Health, London). Nursing practice, education and workforce planning are called upon to adapt accordingly (Department of Health, 2004. The NHS Knowledge and Skills Framework (NHS KSF). Department of Health, London; Kenyon, V., Smith, E., Hefty, L., Bell, M., Martaus, T., 1990. Clinical competencies for community health nursing. Public Health Nursing 7(1), 33-39; United Kingdom Central Council for Nursing, Midwifery and Health Visiting, 1986. Project 2000: A New Preparation for Practice. UKCC, London). Such changes have major implications for pre-registration nursing education, including its practice placement element. From an educational perspective, the need for increased community nursing capacity must be balanced with adequate support for student nurses' learning needs during community-based placements. This qualitative study explored six second year student nurses' experiences of 12 week community-based practice placements and the extent to which these placements were seen to meet their perceived learning needs. The data came from contemporaneous reflective diaries, completed by participants to reflect their 'lived experience' during their practice placements (Landeen, J., Byrne, Brown, B., 1995. Exploring the lived experiences of psychiatric nursing students through self-reflective journals. Journal of Advanced Nursing 21(5), 878-885; Kok, J., Chabeli, M.M., 2002. Reflective journal writing: how it promotes reflective thinking in clinical nursing education: a students' perspective. Curationis 25(3), 35-42; Löfmark, A., Wikblad, K., 2001. Facilitating and

  13. Internship guide : Work placements step by step

    NARCIS (Netherlands)

    Haag, Esther

    2013-01-01

    Internship Guide: Work Placements Step by Step has been written from the practical perspective of a placement coordinator. This book addresses the following questions : what problems do students encounter when they start thinking about the jobs their degree programme prepares them for? How do you

  14. An RTT-Aware Virtual Machine Placement Method

    Directory of Open Access Journals (Sweden)

    Li Quan

    2017-12-01

    Full Text Available Virtualization is a key technology for mobile cloud computing (MCC and the virtual machine (VM is a core component of virtualization. VM provides a relatively independent running environment for different applications. Therefore, the VM placement problem focuses on how to place VMs on optimal physical machines, which ensures efficient use of resources and the quality of service, etc. Most previous work focuses on energy consumption, network traffic between VMs and so on and rarely consider the delay for end users’ requests. In contrast, the latency between requests and VMs is considered in this paper for the scenario of optimal VM placement in MCC. In order to minimize average RTT for all requests, the round-trip time (RTT is first used as the metric for the latency of requests. Based on our proposed RTT metric, an RTT-Aware VM placement algorithm is then proposed to minimize the average RTT. Furthermore, the case in which one of the core switches does not work is considered. A VM rescheduling algorithm is proposed to keep the average RTT lower and reduce the fluctuation of the average RTT. Finally, in the simulation study, our algorithm shows its advantage over existing methods, including random placement, the traffic-aware VM placement algorithm and the remaining utilization-aware algorithm.

  15. CORRELATION ANALYSIS OF A LARGE SAMPLE OF NARROW-LINE SEYFERT 1 GALAXIES: LINKING CENTRAL ENGINE AND HOST PROPERTIES

    International Nuclear Information System (INIS)

    Xu Dawei; Komossa, S.; Wang Jing; Yuan Weimin; Zhou Hongyan; Lu Honglin; Li Cheng; Grupe, Dirk

    2012-01-01

    We present a statistical study of a large, homogeneously analyzed sample of narrow-line Seyfert 1 (NLS1) galaxies, accompanied by a comparison sample of broad-line Seyfert 1 (BLS1) galaxies. Optical emission-line and continuum properties are subjected to correlation analyses, in order to identify the main drivers of the correlation space of active galactic nuclei (AGNs), and of NLS1 galaxies in particular. For the first time, we have established the density of the narrow-line region as a key parameter in Eigenvector 1 space, as important as the Eddington ratio L/L Edd . This is important because it links the properties of the central engine with the properties of the host galaxy, i.e., the interstellar medium (ISM). We also confirm previously found correlations involving the line width of Hβ and the strength of the Fe II and [O III] λ5007 emission lines, and we confirm the important role played by L/L Edd in driving the properties of NLS1 galaxies. A spatial correlation analysis shows that large-scale environments of the BLS1 and NLS1 galaxies of our sample are similar. If mergers are rare in our sample, accretion-driven winds, on the one hand, or bar-driven inflows, on the other hand, may account for the strong dependence of Eigenvector 1 on ISM density.

  16. Immediate Implant Placement and Provisionalization Using the Patient's Extracted Crown: 12-Month Follow-Up.

    Science.gov (United States)

    Deliberador, Tatiana Miranda; Begnini, Gilmar José; Tomazinho, Flávia; Rezende, Carlos Eduardo Edwards; Florez, Fernando Luis Esteban; Leonardi, Denise Piotto

    2018-03-01

    Immediate placement and provisionalization of implants in fresh sockets has been previously demonstrated to be a predictable treatment in the restoration of non-recoverable teeth in the anterior regions of the maxilla. This article reports a clinical case in which an immediate implant placement protocol was used in combination with two distinct and sequential grafts (bovine bone and connective tissue, respectively) followed by immediate implant provisionalization using the patient's crown of an extracted tooth. Physical, clinical, and image examinations of the patient (female, 23 years old) revealed a maxillary central incisor (tooth No. 8) with slight mobility due the presence of extensive cervical resorption. The treatment proposed was the atraumatic extraction of the tooth followed by immediate implant placement and provisionalization. Two grafts (bovine bone and connective tissue) were used due to the presence of a very thin maxillary bone plate associated with a thin gingival biotype. The use of the extracted crown as a temporary crown after immediate implant placement resulted in immediate attainment of an esthetically pleasing outcome and long-term favorable results. The treatment protocol proposed can be efficiently used to immediately restore the patient's esthetics and function while maintaining the health, volume, and contours of gingival tissues over a 12-month follow-up period. Anterior teeth extractions typically require the execution of single-unit prostheses using dental materials of synthetic origin (such as polymers), which often are incapable of achieving the esthetic and physiological results patients expect. The use of the patient's own crown was demonstrated, which allowed good clinical results to be achieved and the natural shape and function of tissues to be maintained.

  17. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  18. Beyond the bundle: a survey of central line-associated bloodstream infection prevention practices used in US and Canadian pediatric hospitals.

    Science.gov (United States)

    Klieger, Sarah B; Potter-Bynoe, Gail; Quach, Caroline; Sandora, Thomas J; Coffin, Susan E

    2013-11-01

    We surveyed US and Canadian pediatric hospitals about their use of central line-associated bloodstream infection (CLABSI) prevention strategies beyond typical insertion and maintenance bundles. We found wide variation in supplemental strategies across hospitals and in their penetration within hospitals. Future studies should assess specific adjunctive prevention strategies and CLABSI rates.

  19. Brand Placement and Consumer Choice: An in-Store Experiment

    Science.gov (United States)

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.…

  20. Neonatal line width in deciduous incisors from Neolithic, mediaeval and modern skeletal samples from north-central Poland.

    Science.gov (United States)

    Kurek, Marta; Żądzińska, Elżbieta; Sitek, Aneta; Borowska-Strugińska, Beata; Rosset, Iwona; Lorkiewicz, Wiesław

    2016-01-01

    The neonatal line is usually the first accentuated incremental line visible on the enamel. The prenatal environment significantly contributes to the width of the neonatal line, influencing the pace of reaching post-delivery homeostasis by the newborn's organism. Studies of the enamel of the earliest developing deciduous teeth can provide an insight into the prenatal development and the perinatal conditions of children of past human populations, thus being an additional source contributing to consideration of the influence of prenatal and perinatal factors modifying growth processes. The aim of this study was to examine whether the neonatal line, reflecting the conditions of the prenatal and perinatal environment, differed between the Neolithic, the mediaeval and the modern populations from the Kujawy region in north-central Poland. The material consisted of longitudinally ground sections of 57 human deciduous incisors obtained from children aged 1.0-7.5 years representing three archaeological series from Brześć Kujawski site. All teeth were sectioned in the labio-linqual plane using a diamond blade (Buechler IsoMet 1000). Final specimens were observed with the microscope Delta Optical Evolution 300 at 10× and 40× magnifications. For each tooth, linear measurements of the neonatal line width were performed on its labial surface at the three levels from the cemento-enamel junction. No significant difference was found in the mean neonatal line width depending on the tooth type and archaeological site, although the thickest neonatal line characterised children from the Neolithic series. In all analysed series, the neonatal line width was diversified depending on the child's age at death. The value of Spearman's rank correlation coefficient calculated for the correlation between the child's age at death and the neonatal line width was statistically significant. A clear increase in the width of the neonatal line was thus observed along with a decrease in the child

  1. Clitoral Pain Following Retropubic Midurethral Sling Placement

    Directory of Open Access Journals (Sweden)

    Melanie Christofferson, DO

    2015-12-01

    Conclusion: Clitoral pain symptoms following placement of a retropubic midurethral sling should be evaluated and promptly addressed, given the potential negative impact on the patient's sexual function. Christofferson M, Barnard J, and Montoya TI. Clitoral pain following retropubic midurethral sling placement. Sex Med 2015;3:346–348.

  2. A physical theory on placement of fertilizers

    NARCIS (Netherlands)

    Wit, de C.T.

    1953-01-01

    A theory was developed enabling calculation of the effect of any placement method of fertilizer on yield if the effect of one method is known.

    This theory was based on the following established facts. The reactions between soil and fertilizer rate are the same for broadcasting and placement

  3. Central line-associated bloodstream infections in adult hematology patients with febrile neutropenia: an evaluation of surveillance definitions using differential time to blood culture positivity.

    Science.gov (United States)

    Freeman, Joshua T; Elinder-Camburn, Anna; McClymont, Catherine; Anderson, Deverick J; Bilkey, Mary; Williamson, Deborah A; Berkahn, Leanne; Roberts, Sally A

    2013-01-01

    We used differential time to positivity between central and peripheral blood cultures to evaluate the positive predictive value (PPV) of the National Healthcare Safety Network central line-associated bloodstream infection (CLABSI) surveillance definition among hematology patients with febrile neutropenia. The PPV was 27.7%, which suggests that, when the definition is applied to this population, CLABSI rates will be substantially overestimated.

  4. Radiography students' perceptions of clinical placements - A Nigerian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Ogbu, S.O.I. [Department of Medical Radiography and Radiological Sciences, University of Nigeria, Enugu Campus, 11 Clement Nnakwe Close, Ugbene, Abakpa-Nike, Enugu State 400001 (Nigeria)], E-mail: sylvogbu_rad@yahoo.com

    2008-05-15

    Purpose: To assess undergraduate radiography student perception of clinical placements and to evaluate their clinical learning experiences. Methods: To evaluate student perception of clinical placements, a Likert-scale questionnaire was used to assess clinical practice, the practice-learning environment. One hundred and seventy-eight undergraduate [student] radiographers participated in the study. Results: The students indicated they had adequate and enjoyed their time on the clinical placement. They also indicated the qualified staff was supportive, friendly and approachable. The students were able to achieve their learning outcomes during the placement. However placement venues, according to the students, had inadequate learning resources. No radiographic/medical imaging research findings, whether locally generated or otherwise, were used in clinical practice. Conclusions: Clinical placements had adequate student support. It provided a pleasant learning experience for the students and it enhanced their skills. Staff was willing and available to assist learning. Nevertheless, the training institutions, professional body and clinical placement providers need to make an effort to address inadequate learning resources (e.g. IT, library, study rooms) as well as the non-utilization of radiographic/medical imaging research findings.

  5. Factors influencing radiation therapy student clinical placement satisfaction

    Science.gov (United States)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning. PMID:26229635

  6. Factors influencing radiation therapy student clinical placement satisfaction

    Energy Technology Data Exchange (ETDEWEB)

    Bridge, Pete; Carmichael, Mary-Ann [School of Clinical Sciences, Queensland University of Technology, Brisbane (Australia)

    2014-02-15

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning.

  7. Factors influencing radiation therapy student clinical placement satisfaction

    International Nuclear Information System (INIS)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning

  8. Pragmatic Approach for Multistage Phasor Measurement Unit Placement

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thoegersen, Poul

    2016-01-01

    Effective phasor measurement unit (PMU) placement is a key to the implementation of efficient and economically feasible wide area measurement systems in modern power systems. This paper proposes a pragmatic approach for cost-effective stage-wise deployment of PMUs while considering realistic...... constraints. Inspired from a real world experience, the proposed approach optimally allocates PMU placement in a stage-wise manner. The proposed approach also considers large-scale wind integration for effective grid state monitoring of wind generation dynamics. The proposed approach is implemented...... on the Danish power system projected for the year 2040. Furthermore, practical experience learnt from an optimal PMU placement project aimed at PMU placement in the Danish power system is presented, which is expected to provide insight of practical challenges at ground level that could be considered by PMU...

  9. Private Placement Debt Financing for Public Entities

    Science.gov (United States)

    Holman, Lance S.

    2010-01-01

    Private placement financing is a debt or capital lease obligation arranged between a municipality or a 501(c) (3) not-for-profit organization and a single sophisticated institutional investor. The investor can be a bank, insurance company, finance company, hedge fund, or high-net worth individual. Private placement financing is similar to…

  10. Patterns of out-of-home placement decision-making in child welfare.

    Science.gov (United States)

    Chor, Ka Ho Brian; McClelland, Gary M; Weiner, Dana A; Jordan, Neil; Lyons, John S

    2013-10-01

    Out-of-home placement decision-making in child welfare is founded on the best interest of the child in the least restrictive setting. After a child is removed from home, however, little is known about the mechanism of placement decision-making. This study aims to systematically examine the patterns of out-of-home placement decisions made in a state's child welfare system by comparing two models of placement decision-making: a multidisciplinary team decision-making model and a clinically based decision support algorithm. Based on records of 7816 placement decisions representing 6096 children over a 4-year period, hierarchical log-linear modeling characterized concordance or agreement, and discordance or disagreement when comparing the two models and accounting for age-appropriate placement options. Children aged below 16 had an overall concordance rate of 55.7%, most apparent in the least restrictive (20.4%) and the most restrictive placement (18.4%). Older youth showed greater discordant distributions (62.9%). Log-linear analysis confirmed the overall robustness of concordance (odd ratios [ORs] range: 2.9-442.0), though discordance was most evident from small deviations from the decision support algorithm, such as one-level under-placement in group home (OR=5.3) and one-level over-placement in residential treatment center (OR=4.8). Concordance should be further explored using child-level clinical and placement stability outcomes. Discordance might be explained by dynamic factors such as availability of placements, caregiver preferences, or policy changes and could be justified by positive child-level outcomes. Empirical placement decision-making is critical to a child's journey in child welfare and should be continuously improved to effect positive child welfare outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Disclosing brand placement to young children

    OpenAIRE

    De Pauw, Pieter; Hudders, Liselot; Cauberghe, Veroline; De Kuysscher, Charlotte

    2015-01-01

    Purpose – This article examines whether a television brand placement warning cue can alter young children’s susceptibility for advertising effects (i.e., brand attitude) through activating their advertising literacy. The proposed model also puts forward an important moderating role for children’s skeptical attitude toward the brand placement format. Design/methodology/approach – The data were collected among 63 children between 7 and 9 years old (Mage = 8.49; 51% girls) through a single...

  12. Laryngeal mask placement in a teaching institution: analysis of difficult placements [version 1; referees: 2 approved, 1 approved with reservations

    Directory of Open Access Journals (Sweden)

    Anastasia D Katsiampoura

    2015-04-01

    Full Text Available Background: Laryngeal mask airway (LMA placement is now considered a common airway management practice. Although there are many studies which focus on various airway techniques, research regarding difficult LMA placement is limited, particularly for anesthesiologist trainees. In our retrospective analysis we tried to identify predictive factors of difficult LMA placement in an academic training program. Methods: This retrospective analysis was derived from a research airway database, where data were collected prospectively at the Memorial Hermann Hospital, Texas Medical Center, Houston, TX, USA, from 2008 to 2010. All non-obstetric adult patients presenting for elective surgery requiring general anesthesia, were enrolled in this study: anesthesiology residents primarily managed the airways. The level of difficulty, number of attempts, and type of the extraglottic device placement were retrieved. Results: Sixty-nine unique Laryngeal Mask Airways (uLMAs were utilized as a primary airway device. Two independent predictors for difficult LMA placement were identified: gender and neck circumference. The sensitivity for one factor is 87.5% with a specificity of 50%. However with two risk factors, the specificity increases to the level of 93% and the sensitivity is 63%. Conclusion: In a large academic training program, besides uLMA not been used routinely, two risk factors for LMA difficulty were identified, female gender and large neck circumference. Neck circumference is increasingly being recognized as a significant predictor across the spectrum of airway management difficulties while female gender has not been previously reported as a risk factor for difficult LMA placement.

  13. 33 CFR 183.566 - Fuel pumps: Placement.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps: Placement. 183.566...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.566 Fuel pumps: Placement. Each fuel pump must be on the engine it serves or within 12 inches of the engine, unless it is a...

  14. Using Learner-Centered, Simulation-Based Training to Improve Medical Students’ Procedural Skills

    Directory of Open Access Journals (Sweden)

    Serkan Toy

    2017-03-01

    Full Text Available Purpose: To evaluate the effectiveness of a learner-centered, simulation-based training developed to help medical students improve their procedural skills in intubation, arterial line placement, lumbar puncture, and central line insertion. Method: The study participants were second and third year medical students. Anesthesiology residents provided the training and evaluated students’ procedural skills. Two residents were present at each station to train the medical students who rotated through all 4 stations. Pre/posttraining assessment of confidence, knowledge, and procedural skills was done using a survey, a multiple-choice test, and procedural checklists, respectively. Results: In total, 24 students were trained in six 4-hour sessions. Students reported feeling significantly more confident, after training, in performing all 4 procedures on a real patient ( P < .001. Paired-samples t tests indicated statistically significant improvement in knowledge scores for intubation, t (23 = −2.92, P < .001, and arterial line placement, t (23 = −2.75, P < .001. Procedural performance scores for intubation ( t (23 = −17.29, P < .001, arterial line placement ( t (23 = −19.75, P < .001, lumbar puncture ( t (23 = −16.27, P < .001, and central line placement ( t (23 = −17.25, P < .001 showed significant improvement. Intraclass correlation coefficients indicated high reliability in checklist scores for all procedures. Conclusions: The simulation sessions allowed each medical student to receive individual attention from 2 residents for each procedure. Students’ written comments indicated that this training modality was well received. Results showed that medical students improved their self-confidence, knowledge, and skills in the aforementioned procedures.

  15. The Re-Placement Test: Using TOEFL for Purposes of Placement

    Science.gov (United States)

    Moglen, Daniel

    2015-01-01

    This article will consider using TOEFL scores for purposes of placement and advising for international graduate students at a northern California research university. As the number of international students is on the rise and the funds for the graduate ESL program are diminishing, the way in which the university is handling the influx of…

  16. Optimal Placement of A Heat Pump in An Integrated Power and Heat Energy System

    DEFF Research Database (Denmark)

    Klyapovskiy, Sergey; You, Shi; Bindner, Henrik W.

    2017-01-01

    With the present trend towards Smart Grids and Smart Energy Systems it is important to look for the opportunities for integrated development between different energy sectors, such as electricity, heating, gas and transportation. This paper investigates the problem of optimal placement of a heat...... pump – a component that links electric and heating utilities together. The system used to demonstrate the integrated planning approach has two neighboring 10kV feeders and several distribution substations with loads that require central heating from the heat pump. The optimal location is found...

  17. The Effect of Product Placement Marketing on Effectiveness of Internet Advertising

    Science.gov (United States)

    Liao, Hsiu-Li; Liu, Su-Houn; Pi, Shih-Ming; Chen, Hui-Ju

    Compared to the traditional way of doing advertising, such as ad Banners, internet product placement is now emerging as a promising strategy for advertisers to do their job effectively in this Web 2.0 era. Therefore, this study focuses on the effectiveness of product placement advertising on the Internet. The results show that product prominence (Subtle or Prominent) and presentation of the advertising (Video or Images) significantly impacts the effectiveness of product placement advertising on the Internet, including brand impression, advertising attitude, and intention to click. Product prominence and presentation of the advertisement have an interactive impact. Our findings indicated that presenting the product through videos will enhance higher levels of advertising attitude, brand impression, and intention to click than presenting it through still images. Subtle placements will increase the level of advertising attitude and intention to click more so than prominent placements. But prominent placements increase the brand impression more than the subtle placements.

  18. This is Advertising! Effects of Disclosing Television Brand Placement on Adolescents.

    Science.gov (United States)

    van Reijmersdal, Eva A; Boerman, Sophie C; Buijzen, Moniek; Rozendaal, Esther

    2017-02-01

    As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing television brand placements and disclosure duration on adolescents' persuasion knowledge (i.e., recognition of brand placement as being advertising, understanding that brand placement has a persuasive intent and critical attitude toward brand placement) and brand responses (i.e., brand memory and brand attitude). To do so, an earlier study that was conducted among adults was replicated among adolescents aged 13-17 years (N = 221, 44 % female). The present study shows that brand placement disclosure had limited effects on adolescents' persuasion knowledge as it only affected adolescents' understanding of persuasive intent, did not mitigate persuasion, but did increase brand memory. These findings suggest that brand placement disclosure has fundamentally different effects on adolescents than on adults: the disclosures had less effects on activating persuasion knowledge and mitigating persuasion among adolescents than among adults. Implications for advertising disclosure regulation and consequences for advertisers are discussed.

  19. Emerging: An Art Field Placement's Impact on Practice

    Science.gov (United States)

    Averett, Paige; Spence, Christina Hall

    2018-01-01

    This exploratory study examined the experiences of 9 stakeholders in an art gallery field placement during their social work education. The study sought to understand how the nontraditional field placement prepared students for practice. In addition, personality traits of students that best fit the placement was examined. Findings suggest that…

  20. Structural challenges of holiday placement programmes for children ...

    African Journals Online (AJOL)

    Structural challenges of holiday placement programmes for children in SOS's Children Village, Zimbabwe. ... African Journal of Social Work ... Response to child protection crisis has essentially seen the placement of orphans and other vulnerable children in residential care institutions, particularly children' homes modelled ...

  1. ESL Placement and Schools: Effects on Immigrant Achievement.

    Science.gov (United States)

    Callahan, Rebecca; Wilkinson, Lindsey; Muller, Chandra; Frisco, Michelle

    2009-05-01

    In this study, the authors explore English as a Second Language (ESL) placement as a measure of how schools label and process immigrant students. Using propensity score matching and data from the Adolescent Health and Academic Achievement Study and the National Longitudinal Study of Adolescent Health, the authors estimate the effect of ESL placement on immigrant achievement. In schools with more immigrant students, the authors find that ESL placement results in higher levels of academic performance; in schools with few immigrant students, the effect reverses. This is not to suggest a one-size-fits-all policy; many immigrant students, regardless of school composition, generational status, or ESL placement, struggle to achieve at levels sufficient for acceptance to a 4-year university. This study offers several factors to be taken into consideration as schools develop policies and practices to provide immigrant students opportunities to learn.

  2. Rotation placements help students' understanding of intensive care.

    Science.gov (United States)

    Abbott, Lisa

    2011-07-01

    It is vital that children's nursing students are fit for practice when they qualify and are able to meet various essential skills as defined by the Nursing and Midwifery Council (NMC). To gain the knowledge and skills required, students need placements in areas where high dependency and potentially intensive care are delivered. Efforts to maximise the number of students experiencing intensive care as a placement have led to the development of the paediatric intensive care unit (PICU) rotation, increasing placements on the PICU from 5 to 40 per cent of the student cohort per year. The lecturer practitioner organises the rotation, providing credible links between university and practice areas, while supporting students and staff in offering a high-quality placement experience. Students say the rotation offers a positive insight into PICU nursing, helping them develop knowledge and skills in a technical area and creating an interest in this specialty.

  3. Determination of anatomic landmarks for optimal placement in captive-bolt euthanasia of goats.

    Science.gov (United States)

    Plummer, Paul J; Shearer, Jan K; Kleinhenz, Katie E; Shearer, Leslie C

    2018-03-01

    OBJECTIVE To determine the optimal anatomic site and directional aim of a penetrating captive bolt (PCB) for euthanasia of goats. SAMPLE 8 skulls from horned and polled goat cadavers and 10 anesthetized horned and polled goats scheduled to be euthanized at the end of a teaching laboratory. PROCEDURES Sagittal sections of cadaver skulls from 8 horned and polled goats were used to determine the ideal anatomic site and aiming of a PCB to maximize damage to the midbrain region of the brainstem for euthanasia. Anatomic sites for ideal placement and directional aiming were confirmed by use of 10 anesthetized horned and polled goats. RESULTS Clinical observation and postmortem examination of the sagittal sections of skulls from the 10 anesthetized goats that were euthanized confirmed that perpendicular placement and firing of a PCB at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear, resulted in consistent disruption of the midbrain and thalamus in all goats. Immediate cessation of breathing, followed by a loss of heartbeat in all 10 of the anesthetized goats, confirmed that use of this site consistently resulted in effective euthanasia. CONCLUSIONS AND CLINICAL RELEVANCE Damage to the brainstem and key adjacent structures may be accomplished by firing a PCB perpendicular to the skull over the anatomic site identified at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear.

  4. Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation

    International Nuclear Information System (INIS)

    Liang, Huei-Lung; Pan, Huay-Ben; Lin, Yih-Huie; Chen, Chiung-Yu; Lai, Pin-Hong; Yang, Chien-Fang; Chung, Hsiao-Min; Wu, Tung-Ho; Chou, Kang-Ju

    2006-01-01

    We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patents (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates (±standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69%±9 and 88%±6,41% ±10 and 88%±6, 30%±10 and 77%±10, and 12%±8 and 61%±13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51%±16 and 86%±13 vs 45%±15 and 73%±13 at 6 months, and 25%±15 and 71%±17 vs 23%±17 and 73%±13 at 12 months (ρ = .436 and .224), respectively. Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen

  5. Radiologic placement of implantable chest ports in pediatric patients under sedation

    International Nuclear Information System (INIS)

    Shin, Tae Beom

    2003-01-01

    To evaluate the safety and efficacy of the radiologic placement of implantable chest ports under intravenous sedation in pediatric patients with malignancy. Between October 2001 and June 2002, 20 chest ports were placed in 19 pediatric patients [13 boys and six girls aged 1-11 (mean, 4.7) years] for the purpose of long-term chemotherapy. In three patients, tunneled central venous catheters had been removed because of catheter extration, infection, and tearing. Under intravenous sedation, the right internal jugular vein was used for access in 19 cases, and the left internal jugular vein in one. Venipucture was performed using a micropuncture needle with real-time ultrasound guidance. A port chamber was created at the infraclavicular fossa, and to prevent catheter kinking, a smooth-angled tunnel was created between the venipuncture site and the subcutaneous pocket. The catheter tip was positioned under fluoroscopy at the junction of the superior vena cava and right atrium. We observed technical success, complications arouse during and after the procedure, and duration of catheter use. Implantation of the port system was successful in all cases, though slight hematoma, treated with manual compression, occurred at a chamber pocket in one case. In addition, the port system was removed from one patient because of wound infection leading to dehiscence and catheter malpositiong. A new port system was implanted through the left internal jugular vein. The median period during which catheter use was followed up was 118 (range, 18-274) days. For long-term chemotherapy in pediatric patients with malignancy, radiologic placement of an implantable chest port under intravenous sedation shows a high technical success rate, with few complications. This method may thus be used instead of surgical port placement

  6. Assessing patient risk of central line-associated bacteremia via machine learning.

    Science.gov (United States)

    Beeler, Cole; Dbeibo, Lana; Kelley, Kristen; Thatcher, Levi; Webb, Douglas; Bah, Amadou; Monahan, Patrick; Fowler, Nicole R; Nicol, Spencer; Judy-Malcolm, Alisa; Azar, Jose

    2018-04-13

    Central line-associated bloodstream infections (CLABSIs) contribute to increased morbidity, length of hospital stay, and cost. Despite progress in understanding the risk factors, there remains a need to accurately predict the risk of CLABSIs and, in real time, prevent them from occurring. A predictive model was developed using retrospective data from a large academic healthcare system. Models were developed with machine learning via construction of random forests using validated input variables. Fifteen variables accounted for the most significant effect on CLABSI prediction based on a retrospective study of 70,218 unique patient encounters between January 1, 2013, and May 31, 2016. The area under the receiver operating characteristic curve for the best-performing model was 0.82 in production. This model has multiple applications for resource allocation for CLABSI prevention, including serving as a tool to target patients at highest risk for potentially cost-effective but otherwise time-limited interventions. Machine learning can be used to develop accurate models to predict the risk of CLABSI in real time prior to the development of infection. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Comparing Administrative and Clinical Data for Central Line Associated Blood Stream Infections in Pediatric Intensive Care Unit and Pediatric Cardiothoracic Intensive Care Unit

    Science.gov (United States)

    Bond, Jory; Issa, Mohamed; Nasrallah, Ali; Bahroloomi, Sheena; Blackwood, Roland A.

    2016-01-01

    Central line associated bloodstream infections (CLABSIs) are a frequent source of health complication for patients of all ages, including for patients in the pediatric intensive care unit (PICU) and Pediatric Cardiothoracic Intensive Care Unit (PCTU). Many hospitals, including the University of Michigan Health System, currently use the International Classification of Disease (ICD) coding system when coding for CLABSI. The purpose of this study was to determine the accuracy of coding for CLABSI infections with ICD-9CM codes in PICU and PCTU patients. A retrospective chart review was conducted for 75 PICU and PCTU patients with 90 events of hospital acquired central line infections at the University of Michigan Health System (from 2007-2011). The different variables examined in the chart review included the type of central line the patient had, the duration of the stay of the line, the type of organism infecting the patient, and the treatment the patient received. A review was conducted to assess if patients had received the proper ICD-9CM code for their hospital acquired infection. In addition, each patient chart was searched using Electronic Medical Record Search Engine to determine if any phrases that commonly referred to hospital acquired CLABSIs were present in their charts. Our review found that in most CLABSI cases the hospital’s administrative data diagnosis using ICD-9CM coding systems did not code for the CLABSI. Our results indicate a low sensitivity of 32% in the PICU and an even lower sensitivity of 12% in the PCTU. Using these results, we can conclude that the ICD-9CM coding system cannot be used for accurately defining hospital acquired CLABSIs in administrative data. With the new use of the ICD-10CM coding system, further research is needed to assess the effects of the ICD-10CM coding system on the accuracy of administrative data.

  8. Comparing administrative and clinical data for central line associated blood stream infections in Pediatric Intensive Care Unit and Pediatric Cardiothoracic Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Jory Bond

    2016-10-01

    Full Text Available Central line associated bloodstream infections (CLABSIs are a frequent source of health complication for patients of all ages, including for patients in the pediatric intensive care unit (PICU and Pediatric Cardiothoracic Intensive Care Unit (PCTU. Many hospitals, including the University of Michigan Health System, currently use the International Classification of Disease (ICD coding system when coding for CLABSI. The purpose of this study was to determine the accuracy of coding for CLABSI infections with ICD-9CM codes in PICU and PCTU patients. A retrospective chart review was conducted for 75 PICU and PCTU patients with 90 events of hospital acquired central line infections at the University of Michigan Health System (from 2007-2011. The different variables examined in the chart review included the type of central line the patient had, the duration of the stay of the line, the type of organism infecting the patient, and the treatment the patient received. A review was conducted to assess if patients had received the proper ICD-9CM code for their hospital acquired infection. In addition, each patient chart was searched using Electronic Medical Record Search Engine to determine if any phrases that commonly referred to hospital acquired CLABSIs were present in their charts. Our review found that in most CLABSI cases the hospital’s administrative data diagnosis using ICD-9CM coding systems did not code for the CLABSI. Our results indicate a low sensitivity of 32% in the PICU and an even lower sensitivity of 12% in the PCTU. Using these results, we can conclude that the ICD-9CM coding system cannot be used for accurately defining hospital acquired CLABSIs in administrative data. With the new use of the ICD- 10CM coding system, further research is needed to assess the effects of the ICD-10CM coding system on the accuracy of administrative data.

  9. Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume II. Text

    Energy Technology Data Exchange (ETDEWEB)

    Slemmons, A J

    1980-04-01

    The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)

  10. Determining the brand awareness of product placement in video games

    OpenAIRE

    Král, Marek

    2015-01-01

    This bachelor thesis focusses on the determination of the brand awareness of product placement in video games. The theoretical part includes information about marketing, product placement and video games. The practical part consists of evaluation of the market research about product placements in video games. Conclusion suggests the most important factors influencing the level brand awareness.

  11. The Placement Handbook. A Guide for the Competitive Employment of the Handicapped.

    Science.gov (United States)

    Horn, Adelaide; Drury, Stephen

    This handbook stresses those components that are considered peripheral to the placement process but that must precede the actual placement. The philosophy of placement upon which this guide is based appears first. Discussions follow of the basic components of the process of training and placement of handicapped individuals, including a varied…

  12. 25 CFR 26.4 - Who administers the Job Placement and Training Program?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who administers the Job Placement and Training Program... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training Program? The Job Placement and Training Program is administered by the Bureau of Indian Affairs or a...

  13. Placement Design of Changeable Message Signs on Curved Roadways

    Directory of Open Access Journals (Sweden)

    Zhongren Wang, Ph.D. P.E. T.E.

    2015-01-01

    Full Text Available This paper presented a fundamental framework for Changeable Message Sign (CMS placement design along roadways with horizontal curves. This analytical framework determines the available distance for motorists to read and react to CMS messages based on CMS character height, driver's cone of vision, CMS pixel's cone of legibility, roadway horizontal curve radius, and CMS lateral and vertical placement. Sample design charts were developed to illustrate how the analytical framework may facilitate CMS placement design.

  14. GoPro HERO 4 Black recording of scleral buckle placement during retinal detachment repair.

    Science.gov (United States)

    Ho, Vincent Y; Shah, Vaishali G; Yates, David M; Shah, Gaurav K

    2017-08-01

    GoPro and Google Glass technology have previously been used to record procedures in ophthalmology and other medical fields. In this manuscript, GoPro's latest HERO 4 Black edition camera (GoPro Inc, San Mateo, Calif.) will be used to record the placement of a scleral buckle during retinal detachment surgery. GoPro HERO 4 Black edition camera, which records 4K-quality video with a resolution of 3840 (pixels) x 2160 (lines), was mounted on a head strap to record placement of a scleral buckle for a retinal detachment. Excellent video quality was achieved with the 4K SuperView setting. Bluetooth connection with an Apple iPad (Apple Inc, Cupertino, Calif.) provided live streaming and use of the GoPro App. Zoom, horizontal/vertical alignment, exposure, and contrast adjustments were made with postproduction editing on GoPro Studio software. Video recording with the GoPro HERO 4 Black edition camera is an excellent way to document extraocular procedures to improve medical education, self-training, or medicolegal documentation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  15. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  16. A linear programming approach for placement of applicants to academic programs

    OpenAIRE

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the ...

  17. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Streitparth, Florian; Gebauer, Bernhard; Benter, Thomas

    2010-01-01

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.

  18. 20 CFR 638.409 - Placement and job development.

    Science.gov (United States)

    2010-04-01

    ... Section 638.409 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR JOB CORPS... Placements in the Job Corps § 638.409 Placement and job development. The overall objective of all Job Corps... issued by the Job Corps Director. (a) The Regional Director, as contracting officer, shall contract with...

  19. FROM BRAND PLACEMENT TO TOURISM PRODUCT PLACEMENT. FICTION SERIES AS PROMOTIONAL SUPPORT OF SPANISH TOURISM DESTINATIONS

    Directory of Open Access Journals (Sweden)

    Noelia Araújo-Vila

    2011-12-01

    Full Text Available Every day more consumers spend much of their free time to the consumption of audiovisual series, which is reflected in the notable increase in downloads and audiences. Therefore, many sectors have decided to use audiovisual series as advertising (brand placement, being one of them the tourism sector (tourism product placement. There are many worldwide destinations that have decided to set in a fiction series, thus being viewed by thousands of spectators, which has resulted in increases in visitors. In the Spanish case is not so clear the use of this strategy, as it is analysed in this article.

  20. Mathematics Course Placement Using Holistic Measures: Possibilities for Community College Students

    Science.gov (United States)

    Ngo, Federick; Chi, W. Edward; Park, Elizabeth So Yun

    2018-01-01

    Background/Context: Most community colleges across the country use a placement test to determine students' readiness for college-level coursework, yet these tests are admittedly imperfect instruments. Researchers have documented significant problems stemming from overreliance on placement testing, including placement error and misdiagnosis of…

  1. M112 Demolition Block Pack-Out Line Modernization

    Science.gov (United States)

    2010-03-01

    1 - Continue to use hot water bath, replacing the steam heating source from the Line B fuel-oil fired boiler with an electric boiler located at l...are manually placed in carriers on an overhead monorail conveyor at the Tipper Tie operation and automatically conveyed through the dip tank. Air...bagged pellets are then manually removed from the overhead monorail , dried with a hand towel, and placed in a holding tray for manual placement into

  2. German causative events with placement verbs

    Directory of Open Access Journals (Sweden)

    De Knop Sabine

    2016-06-01

    Full Text Available Several studies have described the semantic uses of German posture verbs, but only few have dealt with German placement verbs. The present study wants to make up for this gap. Starting from a collection of examples from the core corpora of the Digitales Wörterbuch der Deutschen Sprache (DWDS and some former studies on posture verbs, it first describes the variety of the most common German placement verbs stellen (‘to put upright’, legen (‘to lay down’, setzen (‘to set’ and stecken (‘to stick’.

  3. CATTLE FEEDER BEHAVIOR AND FEEDER CATTLE PLACEMENTS

    OpenAIRE

    Kastens, Terry L.; Schroeder, Ted C.

    1994-01-01

    Cattle feeders appear irrational when they place cattle on feed when projected profit is negative. Long futures positions appear to offer superior returns to cattle feeding investment. Cattle feeder behavior suggests that they believe a downward bias in live cattle futures persists and that cattle feeders use different expectations than the live cattle futures market price when making placement decisions. This study examines feeder cattle placement determinants, comparing performance of expec...

  4. Pregnancy Outcomes After Myomectomy With Polytetrafluoroethylene Placement

    OpenAIRE

    Eaton, Jennifer L.; Milad, Magdy P.

    2014-01-01

    Background and Objectives: The aim of this study was to report preliminary data on pregnancy outcomes after myomectomy with placement of an expanded polytetrafluoroethylene adhesion barrier membrane. Methods: In this retrospective case series, 68 women who underwent myomectomy with expanded polytetrafluoroethylene membrane placement between January 1, 2003, and December 31, 2009, were identified. Of these women, 15 subsequently had documented pregnancies and were included in the final dataset...

  5. Wavelength converter placement in optical networks with dynamic traffic

    DEFF Research Database (Denmark)

    Buron, Jakob Due; Ruepp, Sarah Renée; Wessing, Henrik

    2008-01-01

    We evaluate the connection provisioning performance of GMPLS-controlled wavelength routed networks under dynamic traffic load and using three different wavelength converter placement heuristics. Results show that a simple uniform placement heuristic matches the performance of complex heuristics...

  6. Value-based distributed generator placements for service quality improvements

    Energy Technology Data Exchange (ETDEWEB)

    Teng, Jen-Hao; Chen, Chi-Fa [Department of Electrical Engineering, I-Shou University, No. 1, Section 1, Syuecheng Road, Dashu Township, Kaohsiung Country 840 (Taiwan); Liu, Yi-Hwa [Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei (Taiwan); Chen, Chia-Yen [Department of Computer Science, The University of Auckland (New Zealand)

    2007-03-15

    Distributed generator (DG) resources are small, self-contained electric generating plants that can provide power to homes, businesses or industrial facilities in distribution feeders. They can be used to reduce power loss and improve service reliability. However, the values of DGs are largely dependent on their types, sizes and locations as they were installed in distribution feeders. A value-based method is proposed in this paper to enhance the reliability and obtain the benefits for DG placement. The benefits of DG placement described in this paper include power cost saving, power loss reduction, and reliability enhancement. The costs of DG placement include the investment, maintenance and operating costs. The proposed value-based method tries to find the best tradeoff between the costs and benefits of DG placement and then find the optimal types of DG and their corresponding locations and sizes in distribution feeders. The derived formulations are solved by a genetic algorithm based method. Test results show that with proper types, sizes and installation site selection, DG placement can be used to improve system reliability, reduce customer interruption costs and save power cost; as well as enabling electric utilities to obtain the maximal economical benefits. (author)

  7. Life cycle assessment for dredged sediment placement strategies.

    Science.gov (United States)

    Bates, Matthew E; Fox-Lent, Cate; Seymour, Linda; Wender, Ben A; Linkov, Igor

    2015-04-01

    Dredging to maintain navigable waterways is important for supporting trade and economic sustainability. Dredged sediments are removed from the waterways and then must be managed in a way that meets regulatory standards and properly balances management costs and risks. Selection of a best management alternative often results in stakeholder conflict regarding tradeoffs between local environmental impacts associated with less expensive alternatives (e.g., open water placement), more expensive measures that require sediment disposal in constructed facilities far away (e.g., landfills), or beneficial uses that may be perceived as risky (e.g., beach nourishment or island creation). Current sediment-placement decisions often focus on local and immediate environmental effects from the sediment itself, ignoring a variety of distributed and long-term effects from transportation and placement activities. These extended effects have implications for climate change, resource consumption, and environmental and human health, which may be meaningful topics for many stakeholders not currently considered. Life-Cycle Assessment (LCA) provides a systematic and quantitative method for accounting for this wider range of impacts and benefits across all sediment management project stages and time horizons. This paper applies a cradle-to-use LCA to dredged-sediment placement through a comparative analysis of potential upland, open water, and containment-island placement alternatives in the Long Island Sound region of NY/CT. Results suggest that, in cases dealing with uncontaminated sediments, upland placement may be the most environmentally burdensome alternative, per ton-kilometer of placed material, due to the emissions associated with diesel fuel combustion and electricity production and consumption required for the extra handling and transportation. These results can be traded-off with the ecosystem impacts of the sediments themselves in a decision-making framework. Published by

  8. Impact of an international workplace learning placement on personal and professional development.

    Science.gov (United States)

    Davies, Kerryn; Curtin, Michael; Robson, Kristy

    2017-04-01

    Workplace learning (WPL) placements are a mandatory part of occupational therapy courses. There is some evidence that suggests WPL placements in international settings are beneficial for students' learning, and personal and professional development. The aim of this study was to explore the impact an international WPL placement in Vietnam had on the perceived personal and professional development of a group of Australian occupational therapy graduates. Interpretative phenomenological analysis was used to explore the perceptions of how participation in the Charles Sturt University School of Community Health's Vietnam placement influenced the personal and professional development of occupational therapy graduates. Individual semi-structured interviews were conducted with nine graduates who participated in the Vietnam placement when they were final year occupational therapy students. Interviews were audio-recorded, transcribed verbatim and individually analysed to identify key themes. Two major themes emerged from the analysis: becoming resourceful, resilient and confident, and becoming respectful of difference. The participants indicated that participation in the Vietnam placement had a positive impact on their personal and professional development. Participants indicated that the Vietnam placement enabled them to develop their resourcefulness, resilience, reasoning skills, cultural competence, confidence and independence, beyond what they felt would have achieved on a domestic placement. For these reason these participants found the placement a beneficial and worthwhile experience. © 2016 Occupational Therapy Australia.

  9. Combined echo offset (Dixon) and line volume chemical shift imaging as a clinical imaging protocol

    International Nuclear Information System (INIS)

    Listerud, J.; Chan, T.; Lenkinski, R.E.; Kressel, H.Y.; Chao, P.W.

    1989-01-01

    The authors have studied the sensitivity and specificity of the line-volume chemical-shift imaging (CSI) method as compared with the Dixon method they have recently implemented on a Signa, which supports a variety of options. Potential sources or error for the Dixon method include line broadening due to susceptibility, field inhomogeneity, and errors form olefinic resonances associated with fat, which behave like water in the Dixon regime. The authors investigate whether a combined Dixon/line-volume CSI method could be used to improve the placement of the line volume and to provide higher sensitivity and specificity than does the Dixon method alone

  10. Review of the genera of Conoderinae (Coleoptera, Curculionidae from North America, Central America, and the Caribbean

    Directory of Open Access Journals (Sweden)

    Salvatore S. Anzaldo

    2017-07-01

    Full Text Available The thirty-nine extant genera of Conoderinae known to occur in North America, Central America, and the Caribbean are reviewed based on external morphology. An identification key is provided along with diagnoses, distributions, species counts, and natural history information, when known, for each genus. Morphological character systems of importance for weevil classification are surveyed, potential relationships among the tribes and genera are discussed, and groups most in need of taxonomic and phylogenetic attention are identified. The following genera are transferred to new tribes: Acoptus LeConte, 1876 from the Lechriopini to the Othippiini (new placement and the South American genus Hedycera Pascoe, 1870 from the Lechriopini to the Piazurini (new placement. Philides Champion, 1906 and Philinna Champion, 1906 are transferred from the Lechriopini to Conoderinae incertae sedis (new placement although their placement as conoderines is uncertain. The species Copturomimus cinereus Heller, 1895 is designated as the type species of the genus Copturomimus Heller, 1895.

  11. Line-focus solar central power systems, Phase I. Monthly technical progress report, 31 January 1979-28 February 1979

    Energy Technology Data Exchange (ETDEWEB)

    Slemmons, A J

    1979-03-01

    The work performed during the fifth month of the Phase I study of the High Temperature Line-Focus Solar Central Power System is summarized. During the reporting period, the optical and receiver computer analysis programs and parametricized data have been combined in a computer program to give the projected annualized Bus Bar Energy Costs for a specified design. Although some of the data are incomplete or need further refinement, the program has been used to examine the sensitivity of some parameters, and to make preliminary optimizations.

  12. Heterocyst placement strategies to maximize the growth of cyanobacterial filaments

    International Nuclear Information System (INIS)

    Brown, Aidan I; Rutenberg, Andrew D

    2012-01-01

    Under conditions of limited fixed-nitrogen, some filamentous cyanobacteria develop a regular pattern of heterocyst cells that fix nitrogen for the remaining vegetative cells. We examine three different heterocyst placement strategies by quantitatively modelling filament growth while varying both external fixed-nitrogen and leakage from the filament. We find that there is an optimum heterocyst frequency which maximizes the growth rate of the filament; the optimum frequency decreases as the external fixed-nitrogen concentration increases but increases as the leakage increases. In the presence of leakage, filaments implementing a local heterocyst placement strategy grow significantly faster than filaments implementing random heterocyst placement strategies. With no extracellular fixed-nitrogen, consistent with recent experimental studies of Anabaena sp. PCC 7120, the modelled heterocyst spacing distribution using our local heterocyst placement strategy is qualitatively similar to experimentally observed patterns. As external fixed-nitrogen is increased, the spacing distribution for our local placement strategy retains the same shape, while the average spacing between heterocysts continuously increases. (paper)

  13. Clinical application of transnasal feeding tube placement under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Ge Kunyuan; Ni Caifang; Liu Yizhi; Zhu Xiaoli; Zou Jianwei; Jin Yonghai; Chen Long; Sun Ge; Sun Lingfang; Zhang Dong

    2008-01-01

    Objective: To evaluate the feasibility and effectiveness of duodenal feeding tube placement under fluoroscopic guidance and its clinical application. Methods: The transnasal duodenal nutriment tubes placement under fluoroscopic guidance were performed in 59 patients from June 3th, 2003 to August 17th, 2007. The successful placement of the feeding tube was defined as that of the tube tip was fixed at or distal to the duodenojejunal junction. Results: 57 out of 59 patients were successfully managed by feeding tube placement, with primary successful rate of 96.6% (57/59). The remaining two failures were due to overdistention of the stomach and were further managed after gastrointestinal decompression thoroughly. The mean fluoroscopy time of the procedure was 17.8 minutes with no severe immediate or delayed complications. Conclusion: The transnasal duodenal nutrient feeding tube placement under fluoroscopic guidance is a safe,economic, and effective management for enteral nutrition, providing extensive clinical utilization. (authors)

  14. Transmission Line Series Compensation for Wind Energy Transmission

    International Nuclear Information System (INIS)

    Palanichamy, C; Wong, Y C

    2015-01-01

    Wind energy has demonstrated to be a clean, copious and absolutely renewable source of energy, and the large penetration of it into the power grid indicates that wind energy is considered an effective means of power generation, Transmission of wind energy from remote locations to load centers necessitates long transmission lines. Series compensation is a proven and economical transmission solution to address system power transfer strength, grid stability, and voltage profile issues of long transmission lines. In this paper, a programmable approach to determine the capacitive reactance of series capacitor and optimum location for its placement to achieve maximum power transfer gas been presented. The respective program with sample solutions has been provided for real-time applications. (paper)

  15. Optimal PMU Placement with Uncertainty Using Pareto Method

    Directory of Open Access Journals (Sweden)

    A. Ketabi

    2012-01-01

    Full Text Available This paper proposes a method for optimal placement of Phasor Measurement Units (PMUs in state estimation considering uncertainty. State estimation has first been turned into an optimization exercise in which the objective function is selected to be the number of unobservable buses which is determined based on Singular Value Decomposition (SVD. For the normal condition, Differential Evolution (DE algorithm is used to find the optimal placement of PMUs. By considering uncertainty, a multiobjective optimization exercise is hence formulated. To achieve this, DE algorithm based on Pareto optimum method has been proposed here. The suggested strategy is applied on the IEEE 30-bus test system in several case studies to evaluate the optimal PMUs placement.

  16. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    Science.gov (United States)

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  17. Optimal placement and decentralized robust vibration control for spacecraft smart solar panel structures

    International Nuclear Information System (INIS)

    Jiang, Jian-ping; Li, Dong-xu

    2010-01-01

    The decentralized robust vibration control with collocated piezoelectric actuator and strain sensor pairs is considered in this paper for spacecraft solar panel structures. Each actuator is driven individually by the output of the corresponding sensor so that only local feedback control is implemented, with each actuator, sensor and controller operating independently. Firstly, an optimal placement method for the location of the collocated piezoelectric actuator and strain gauge sensor pairs is developed based on the degree of observability and controllability indices for solar panel structures. Secondly, a decentralized robust H ∞ controller is designed to suppress the vibration induced by external disturbance. Finally, a numerical comparison between centralized and decentralized control systems is performed in order to investigate their effectiveness to suppress vibration of the smart solar panel. The simulation results show that the vibration can be significantly suppressed with permitted actuator voltages by the controllers. The decentralized control system almost has the same disturbance attenuation level as the centralized control system with a bit higher control voltages. More importantly, the decentralized controller composed of four three-order systems is a better practical implementation than a high-order centralized controller is

  18. Relationship Between Technical Errors and Decision-Making Skills in the Junior Resident.

    Science.gov (United States)

    Nathwani, Jay N; Fiers, Rebekah M; Ray, Rebecca D; Witt, Anna K; Law, Katherine E; DiMarco, ShannonM; Pugh, Carla M

    The purpose of this study is to coevaluate resident technical errors and decision-making capabilities during placement of a subclavian central venous catheter (CVC). We hypothesize that there would be significant correlations between scenario-based decision-making skills and technical proficiency in central line insertion. We also predict residents would face problems in anticipating common difficulties and generating solutions associated with line placement. Participants were asked to insert a subclavian central line on a simulator. After completion, residents were presented with a real-life patient photograph depicting CVC placement and asked to anticipate difficulties and generate solutions. Error rates were analyzed using chi-square tests and a 5% expected error rate. Correlations were sought by comparing technical errors and scenario-based decision-making skills. This study was performed at 7 tertiary care centers. Study participants (N = 46) largely consisted of first-year research residents who could be followed longitudinally. Second-year research and clinical residents were not excluded. In total, 6 checklist errors were committed more often than anticipated. Residents committed an average of 1.9 errors, significantly more than the 1 error, at most, per person expected (t(44) = 3.82, p technical errors committed negatively correlated with the total number of commonly identified difficulties and generated solutions (r (33) = -0.429, p = 0.021, r (33) = -0.383, p = 0.044, respectively). Almost half of the surgical residents committed multiple errors while performing subclavian CVC placement. The correlation between technical errors and decision-making skills suggests a critical need to train residents in both technique and error management. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Central line-associated bloodstream infections and catheter dwell-time: A theoretical foundation for a rule of thumb.

    Science.gov (United States)

    Voets, Philip J G M

    2018-05-14

    Many clinicians know from experience and medical epidemiological literature that the risk of central line-associated bloodstream infections (CLABSI) increases rapidly with a prolonged catheter dwell-time, but how this infection risk increases over time remains obscure. In this manuscript, a clinically useful rule of thumb is derived, stating that the risk of CLABSI increases in a quadratic fashion with the increase in catheter dwell-time. The proposed rule of thumb could be considered a quick and effortless clinical tool to rationally predict the pattern of CLABSI risk with an increasing catheter dwell-time. Copyright © 2018. Published by Elsevier Ltd.

  20. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  1. Ultrasound-Guided Cannulation: Time to Bring Subclavian Central Lines Back

    Directory of Open Access Journals (Sweden)

    Talayeh Rezayat, DO, MPH

    2016-03-01

    Full Text Available Despite multiple advantages, subclavian vein (SCV cannulation via the traditional landmark approach has become less used in comparison to ultrasound (US guided internal jugular catheterization due to a higher rate of mechanical complications. A growing body of evidence indicates that SCV catheterization with real-time US guidance can be accomplished safely and efficiently. While several cannulation approaches with real-time US guidance have been described, available literature suggests that the infraclavicular, longitudinal “in-plane” technique may be preferred. This approach allows for direct visualization of needle advancement, which reduces risk of complications and improves successful placement. Infraclavicular SCV cannulation requires simultaneous use of US during needle advancement, but for an inexperienced operator, it is more easily learned compared to the traditional landmark approach. In this article, we review the evidence supporting the use of US guidance for SCV catheterization and discuss technical aspects of the procedure itself.

  2. Hollow mandrin facilitates external ventricular drainage placement.

    Science.gov (United States)

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  3. A Cloud-Computing-Based Data Placement Strategy in High-Speed Railway

    Directory of Open Access Journals (Sweden)

    Hanning Wang

    2012-01-01

    Full Text Available As an important component of China’s transportation data sharing system, high-speed railway data sharing is a typical application of data-intensive computing. Currently, most high-speed railway data is shared in cloud computing environment. Thus, there is an urgent need for an effective cloud-computing-based data placement strategy in high-speed railway. In this paper, a new data placement strategy named hierarchical structure data placement strategy is proposed. The proposed method combines the semidefinite programming algorithm with the dynamic interval mapping algorithm. The semi-definite programming algorithm is suitable for the placement of files with various replications, ensuring that different replications of a file are placed on different storage devices, while the dynamic interval mapping algorithm ensures better self-adaptability of the data storage system. A hierarchical data placement strategy is proposed for large-scale networks. In this paper, a new theoretical analysis is provided, which is put in comparison with several other previous data placement approaches, showing the efficacy of the new analysis in several experiments.

  4. An Aggregated Optimization Model for Multi-Head SMD Placements

    NARCIS (Netherlands)

    Ashayeri, J.; Ma, N.; Sotirov, R.

    2010-01-01

    In this article we propose an aggregate optimization approach by formulating the multi-head SMD placement optimization problem into a mixed integer program (MIP) with the variables based on batches of components. This MIP is tractable and effective in balancing workload among placement heads,

  5. An aggregated optimization model for multi-head SMD placements

    NARCIS (Netherlands)

    Ashayeri, J.; Ma, N.; Sotirov, R.

    2011-01-01

    In this article we propose an aggregate optimization approach by formulating the multi-head SMD placement optimization problem into a mixed integer program (MIP) with the variables based on batches of components. This MIP is tractable and effective in balancing workload among placement heads,

  6. 26 CFR 31.3506-1 - Companion sitting placement services.

    Science.gov (United States)

    2010-04-01

    ....3506-1 Companion sitting placement services. (a) Definitions—(1) Companion sitting placement service... agency that places babysitters with individuals who desire babysitting services. X furnishes all the.... B performs the services four days a week in A's home and follows specific instructions given by A...

  7. FPGA Congestion-Driven Placement Refinement

    Energy Technology Data Exchange (ETDEWEB)

    Vicente de, J.

    2005-07-01

    The routing congestion usually limits the complete proficiency of the FPGA logic resources. A key question can be formulated regarding the benefits of estimating the congestion at placement stage. In the last years, it is gaining acceptance the idea of a detailed placement taking into account congestion. In this paper, we resort to the Thermodynamic Simulated Annealing (TSA) algorithm to perform a congestion-driven placement refinement on the top of the common Bounding-Box pre optimized solution. The adaptive properties of TSA allow the search to preserve the solution quality of the pre optimized solution while improving other fine-grain objectives. Regarding the cost function two approaches have been considered. In the first one Expected Occupation (EO), a detailed probabilistic model to account for channel congestion is evaluated. We show that in spite of the minute detail of EO, the inherent uncertainty of this probabilistic model impedes to relieve congestion beyond the sole application of the Bounding-Box cost function. In the second approach we resort to the fast Rectilinear Steiner Regions algorithm to perform not an estimation but a measurement of the global routing congestion. This second strategy allows us to successfully reduce the requested channel width for a set of benchmark circuits with respect to the widespread Versatile Place and Route (VPR) tool. (Author) 31 refs.

  8. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  9. A risk-based sensor placement methodology

    International Nuclear Information System (INIS)

    Lee, Ronald W.; Kulesz, James J.

    2008-01-01

    A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors to protect population against the exposure to, and effects of, known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure at standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats detected by sensors placed in prior iterations are removed from consideration in subsequent iterations. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal utility of each additional sensor. This is the fraction of the total risk accounted for by placement of the sensor. Thus, the criteria for halting the iterative process can be the number of sensors available, a threshold marginal utility value, and/or a minimum cumulative utility achieved with all sensors

  10. Learning experiences on role-emerging placements: an exploration from the students' perspective.

    Science.gov (United States)

    Dancza, Karina; Warren, Alison; Copley, Jodie; Rodger, Sylvia; Moran, Monica; McKay, Elizabeth; Taylor, Ann

    2013-12-01

    Occupational therapy educators are challenged to provide students with practical experiences which prepare them for ever changing health-care contexts on graduation. Role-emerging placements have been widely used internationally to help meet this challenge, but research into the learning experiences of students during these innovative placements is limited. This research investigated the enablers and barriers to learning from the perspectives of students on such placements from two European universities. Two separate qualitative studies tracked 10 final year students. Interviews explored their learning experiences prior to, during and after an eight- or 10-week role-emerging placement in a range of settings. Four themes emerged, which were (1) adapting to less doing, more thinking and planning; (2) understanding the complexity of collaboration and making it work; (3) emotional extremes; and (4) realising and using the occupational therapy perspective. These placements presented a 'roller coaster' of authentic learning experiences which created the opportunity for students to use occupation in practice and develop skills for collaborative working in an interprofessional environment. Whereas students viewed their role-emerging placement experiences positively, challenges included the emotional responses of students and placement pace. Findings suggest the need for supportive student placement experiences in both established and role-emerging areas to prepare students for a range of opportunities in an uncertain future. © 2013 Occupational Therapy Australia.

  11. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    Science.gov (United States)

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  12. AP: A Critical Examination of the Advanced Placement Program

    Science.gov (United States)

    Sadler, Philip M.; Sonnert, Gerhard; Tai, Robert; Klopfenstein, Kirstin

    2016-01-01

    The Advanced Placement (AP) program was created to enhance the experience of gifted students as they transition from high school to college. "AP: A Critical Examination of the Advanced Placement Program," edited by Philip M. Sadler, Gerhard Sonnert, Robert Tai, and Kirstin Klopfenstein (2010, Harvard Education Press), questions the…

  13. Evidence-based measures to prevent central line-associated bloodstream infections: a systematic review.

    Science.gov (United States)

    Perin, Daniele Cristina; Erdmann, Alacoque Lorenzini; Higashi, Giovana Dorneles Callegaro; Sasso, Grace Teresinha Marcon Dal

    2016-09-01

    to identify evidence-based care to prevent CLABSI among adult patients hospitalized in ICUs. systematic review conducted in the following databases: PubMed, Scopus, Cinahl, Web of Science, Lilacs, Bdenf and Cochrane Studies addressing care and maintenance of central venous catheters, published from January 2011 to July 2014 were searched. The 34 studies identified were organized in an instrument and assessed by using the classification provided by the Joanna Briggs Institute. the studies presented care bundles including elements such as hand hygiene and maximal barrier precautions; multidimensional programs and strategies such as impregnated catheters and bandages and the involvement of facilities in and commitment of staff to preventing infections. care bundles coupled with education and the commitment of both staff and institutions is a strategy that can contribute to decreased rates of central line-associated bloodstream infections among adult patients hospitalized in intensive care units. identificar evidências de cuidados para prevenção de infecção de corrente sanguínea relacionada a cateter venoso central em pacientes adultos em Unidades de Terapia Intensiva. revisão Sistemática realizada por meio de busca nas bases de dados Pubmed, Scopus, Cinahl, Web of Science, Lilacs, Bdenf e Cochrane. Foram buscadas pesquisas com cuidados com a cateterização e manutenção do cateter venoso central, publicados de janeiro de 2011 a julho de 2014. Os 34 estudos incluídos foram organizados em um instrumento e avaliados por meio da classificação do The Joanna Briggs Institute. os estudos apresentaram bundles de cuidados com elementos como a higiene das mãos e precauções máximas de barreira; programas multidimensionais e estratégias como cateteres e curativos impregnados e o envolvimento da instituição e engajamento da equipe nos esforços para prevenção de infecção. os cuidados no formato de bundles aliados com a educação e engajamento da equipe e

  14. Incorrect position of Essure microinserts 3 months after successful bilateral placement.

    Science.gov (United States)

    Gerritse, Maria B E; Veersema, Sebastiaan; Timmermans, Anne; Brölmann, Hans A M

    2009-03-01

    To describe incorrect positions of Essure microinserts detected at 3 months' follow-up. Case report. Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. Initial series of 100 patients who underwent hysteroscopic sterilization using Essure between December 2003 and June 2004. Hysteroscopic placement of the Essure System, follow-up at 3 months with transvaginal ultrasound (TVU), and hysterosalpingography. Bilateral placement rate, tubal obstruction, and detection of incorrect Essure microinsert localization at follow-up after apparent successful bilateral placement. Bilateral placement of Essure microinserts in one session was successful in 93 women (93%). In 90 of these women (96.8%), tubal obstruction was proven at follow-up 3 months later. Three incorrect positions of an Essure insert were seen: two expulsions and one perforation into the abdominal cavity. Incorrect position of Essure microinserts was seen only when the initial placement procedure was difficult. When a placement procedure was difficult or other suboptimal conditions are present during the procedure, we advise performing a TVU or pelvic X-ray in these women 4 weeks after the procedure or after the first vaginal bleeding, instead of waiting for follow-up after 3 months.

  15. Consumers with Major Depressive Disorder: Factors Influencing Job Placement

    Science.gov (United States)

    Hergenrather, Kenneth C.; Haase, Eileen; Zeglin, Robert J.; Rhodes, Scott D.

    2013-01-01

    The theory of planned behavior (TPB) was applied to study the factors that influence the intention of public rehabilitation placement professionals to place consumers with major depressive disorder (MDD) in jobs. A sample of 108 public rehabilitation placement professionals in the Mid-Atlantic region of the United States completed the MDD…

  16. Community placement and reintegration of service users from long ...

    African Journals Online (AJOL)

    Objective: To ascertain community placement and reintegration of service users from long-term mental health care facilities. Method: This study reviewed the progress during 2003 with the alternative placement of a selected candidate group of 27 service users in some of Lifecare's long-term mental health care facilities in ...

  17. Bond graph to digraph conversion: A sensor placement optimization ...

    Indian Academy of Sciences (India)

    In this paper, we consider the optimal sensors placement problem for ... is due to the fact that the construction is generally done from the state equations, ... The Bond Graph (BG) tool defined in Paynter (1961) formal- ... Sensor placement and structural problem formulation .... Thus the obtained four matrices are as follows:.

  18. 28 CFR 541.49 - Review of control unit placement.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Review of control unit placement. 541.49... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.49 Review of control unit placement. (a) Unit staff shall evaluate informally and daily an inmate's adjustment within the control unit...

  19. Study on the placement of phosphorus fertilizer to improve fertilizer utilization by lowland rice

    International Nuclear Information System (INIS)

    Sisworo, W.H.; Riswantoro; Mardjo, M.

    1976-01-01

    An experiment for studying the placement of phosphorus fertilizer was carried out in the glass house by using 32 P-labelled superphosphate. The specific activity of the labelled fertilizer used was 0,25 mCi/g P 2 O 5 . Three placement methods were studied: (1) Hill placement: Fertilizer was burried at a distance of 5cm from the plants at the depth of 5 cm, (2) Surface placement: Fertilizer was spread on the surface, and (3) Soil mixed application: Fertilizer was mixed with the soil at the depth of 5 cm. Superphosphate was applied at the rates of 0, 30, 60, 90, and 120 kg P 25 /ha. Results obtained from the experiment showed that the dry matter production was significantly affected by the methods of placement of phosphorus fertilizer. Soil mixed placement gave the lowest yield of dry plant material. It differed significantly from the two other methods of placement. However, there was no significant difference between hill and surface placement. The placement of phosphorus fertilizer significantly affected the total uptake of phosphorus nutrient, uptake fertilizer phosphorus, and the percentage of fertilizer utilization. Surface placement gave the highest utilization of fertilizer when supplied at rates higher than 60 kg P 2 O 5 /ha. At low rate applications, hill placement was the best, but, at rates higher than 60 kg P 2 O 5 /ha the percentage of fertilizer utilization decreased. Soil mixed application was the least efficient fertilizer utilization. (author)

  20. Hydrogen line formation in the quescent prominences

    International Nuclear Information System (INIS)

    Tsovookhuu, Ch.

    1980-01-01

    Equations of transfer and statistical equilibrium for hydronen atom with eight bound levels and continuum are solved simultaneously. A plane-parallel layer located perpendicular to the Sun surface is taken as a geometrical model. Input parameters of the physical model are optical thickness in the center of Hsub(α) line, electron temperature and concentration in the layer center are well as temperature and density gradients. Functions of sources, line profiles, total energies and the Balmer decrements, which are compared with observations and theoretical calculations made by other authors, have been calculated. The comparison shows that the results are quite acceptable and can be used when analyzing the spectrum and determining physical parameters of solar prominences. Dependence of different performances of the line (equivalent width, central intensity, halfwidth, depth of central depression etc.) on values of initial model parameters is investigated. Line halfwidth is more sensitive to the temperatuu value in the layer center, while central intensity - to the value of temperature gradient and a depth of central depression - to electron concentration. Calculated were shares of primary sources responsible for different excitation mechanism depending on total optical thickness as well as mean probabilities of quantum yield out of a medium which can be used during parametric accountancy of radiation diffusion in solar prominences [ru

  1. Work Placements at 14-15 Years and Employability Skills

    Science.gov (United States)

    Messer, David

    2018-01-01

    Purpose: In the UK, concern frequently has been voiced that young people lack appropriate employability skills. One way to address this is to provide work based placements. In general, previous research findings have indicated that young people find such placements useful because of help with career choice and relevant skills. However, most…

  2. Community Resources and Job Placement

    Science.gov (United States)

    Preston, Jim

    1977-01-01

    In cooperation with the chamber of commerce, various businesses, associations, and other community agencies, the Sarasota schools (Florida) supplement their own job placement and follow-up efforts with community job development strategies for placing high school graduates. (JT)

  3. Demand management through centralized control system using power line communication for existing buildings

    International Nuclear Information System (INIS)

    Al-Mulla, A.; ElSherbini, A.

    2014-01-01

    Highlights: • A pilot system was developed for demand management of equipment in buildings. • The networking was based on LonWorks platform and power line communication. • Demand strategies led to load reductions up to 74% and energy savings up to 25%. • The peak load reduction is expected to reach 3.44 GW by the year 2030. - Abstract: Managing peak demand efficiently is vital for maintaining uninterrupted supply of electrical power by utility providers. In this work, a pilot system was developed for managing and controlling the demand of major power consuming equipment in buildings from a central server, while relying mostly on existing infrastructure and maintaining consumer comfort. The system was successfully demonstrated on a selected group of buildings using the LonWorks networking platform. At the building level, the system utilized power line and twisted pair communication to control the thermostats of air-conditioning (A/C) units. The higher level communication was executed through extensible markup language (XML) and simple object access protocol (SOAP). The system provided control capabilities based on A/C unit priority, thermostat temperature, building type and geographic location. The development and execution of demand management strategies for selected buildings led to peak load reductions up to 74%, in addition to energy savings up to 25%. Implementing such a system at a national level in Kuwait is estimated to reduce peak demand by 3.44 GW, amounting to capital savings of $4.13 billion. The use of existing infrastructure reduced the cost and installation time of the system. Based on the successful testing of this pilot system, a larger-scale system is being developed

  4. Clinical predictors of port infections within the first 30 days of placement.

    Science.gov (United States)

    Bamba, Ravinder; Lorenz, Jonathan M; Lale, Allison J; Funaki, Brian S; Zangan, Steven M

    2014-03-01

    To identify risk factors for port infections within 30 days of placement. A retrospective chart review of port placements from 2002-2009 was conducted. Patients who had port removals secondary to infection within the first 30 days of placement were included. This group of patients was compared with a control group of patients with ports with no evidence of infection. For every one patient with a port infection, two control subjects were chosen of the same gender and new port placement during the same month as the corresponding patient with an infected port. From 2002-2009, 4,404 ports were placed. Of the 4,404 patients, 33 (0.7%) were found to have a port infection within 30 days of placement. Compared with the control group, the early infection group had a higher prevalence of leukopenia (21.2% vs 6.1%, P = .039) and thrombocytopenia (33% vs 12%, P = .0158). There was also a higher prevalence of an inpatient hospital stay during port placement and high international normalized ratio in the early infection group. Low preoperative white blood cell and platelet counts were risk factors for early infection. Abnormal coagulation profiles and inpatient access of ports after placement could be additional risk factors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  5. Characteristics of People Providing Family Placements to Adult Persons with Intellectual Disabilities

    Science.gov (United States)

    McConkey, Roy; McConaghie, Jayne; Roberts, Paul; King, Diana

    2005-01-01

    The success of family placement schemes depends largely on the recruitment of suitable people who are willing to offer placements in their own home yet little research has been undertaken of their characteristics and the reasons for their involvement. Thirty providers of family based placements to adult persons with intellectual disabilities were…

  6. A Case for Faculty Involvement in EAP Placement Testing

    Science.gov (United States)

    James, Cindy; Templeman, Elizabeth

    2009-01-01

    The EAP placement procedure at Thompson Rivers University (TRU) involves multiple measures to assess the language skills of incoming students, some of which are facilitated and all of which are assessed by ESL faculty. In order to determine the effectiveness of this comprehensive EAP placement process and the effect of the faculty factor, a…

  7. Development of cross-border transmission lines in Poland and their significance for the Central East Europeam energy market

    Energy Technology Data Exchange (ETDEWEB)

    Andruszkiewicz, Jerzy

    2010-09-15

    This publication presents the existing cross-border transmission lines connecting Poland with neighbouring countries and their use in the currently applied mechanisms for making available the transfer capacities. The prospects and the considered options of development in cross-border interconnections were presented, taking into account their role in the integration of the European market and of the trade relations with neighbouring counties other than members of the European Community. The role of the planned interconnections in solving the problems of central European countries connected with the implementation of European strategy that reduce CO2 emissions in the area of electricity generation was discussed.

  8. Effect of posterior crown margin placement on gingival health.

    Science.gov (United States)

    Reitemeier, Bernd; Hänsel, Kristina; Walter, Michael H; Kastner, Christian; Toutenburg, Helge

    2002-02-01

    The clinical impact of posterior crown margin placement on gingival health has not been thoroughly quantified. This study evaluated the effect of posterior crown margin placement with multivariate analysis. Ten general dentists reviewed 240 patients with 480 metal-ceramic crowns in a prospective clinical trial. The alloy was randomly selected from 2 high gold, 1 low gold, and 1 palladium alloy. Variables were the alloy used, oral hygiene index score before treatment, location of crown margins at baseline, and plaque index and sulcus bleeding index scores recorded for restored and control teeth after 1 year. The effect of crown margin placement on sulcular bleeding and plaque accumulation was analyzed with regression models (Prisk of bleeding at intrasulcular posterior crown margins was approximately twice that at supragingival margins. Poor oral hygiene before treatment and plaque also were associated with sulcular bleeding. Facial sites exhibited a lower probability of sulcular bleeding than lingual surfaces. Type of alloy did not influence sulcular bleeding. In this study, placement of crown margins was one of several parameters that affected gingival health.

  9. Confirmation of gastric tube bedside placement with the sky blue method.

    Science.gov (United States)

    Imamura, Takashi; Maeda, Hajime; Kinoshita, Hidetoshi; Shibukawa, Yasuko; Suda, Kiyomi; Fukuda, Yutaka; Goto, Aya; Nagasawa, Katsutoshi

    2014-02-01

    The purpose was to review our experiences and determine if applying the sky blue method is reliable in confirming gastric tube (GT) placement in neonates. The study population consisted of 44 infants (55 placements) who were admitted to the Takeda General Hospital between April 2012 and March 2013 and who required GT exchange. The sky blue method using indigo carmine (IC) was indicated for planned tube exchange only. Diluted IC was injected into the gastric space via the old GT just before the tube exchange. The tube was exchanged using a standard method. Then, we checked whether the diluted IC could be collected through the new GT or not. The reasons for GT placement were a gestational age of sky blue method was considered successful in 52 placements (94.4%), with the remaining 3 placements (5.6%) considered to be failures due to the inability to obtain IC from the gastric space. No adverse events were observed during the tube exchange period. Based on the results, the sky blue method can be considered to be reliable method for the confirmation of GT placement. These results also suggest that the number of radiologic evaluations performed to confirm correct replacement of the GT in infants can be reduced in the future.

  10. Isotropic Optical Mouse Placement for Mobile Robot Velocity Estimation

    Directory of Open Access Journals (Sweden)

    Sungbok Kim

    2014-06-01

    Full Text Available This paper presents the isotropic placement of multiple optical mice for the velocity estimation of a mobile robot. It is assumed that there can be positional restriction on the installation of optical mice at the bottom of a mobile robot. First, the velocity kinematics of a mobile robot with an array of optical mice is obtained and the resulting Jacobian matrix is analysed symbolically. Second, the isotropic, anisotropic and singular optical mouse placements are identified, along with the corresponding characteristic lengths. Third, the least squares mobile robot velocity estimation from the noisy optical mouse velocity measurements is discussed. Finally, simulation results for several different placements of three optical mice are given.

  11. Measurement of the central ion and electron temperature of tokamak plasmas from the x-ray line radiation of high-Z impurity ions

    International Nuclear Information System (INIS)

    Bitter, M.; von Goeler, S.; Goldman, M.; Hill, K.W.; Horton, R.; Roney, W.; Sauthoff, N.; Stodiek, W.

    1982-04-01

    This paper describes measurements of the central ion and electron temperature of tokamak plasmas from the observation of the 1s - 2p resonance lines, and the associated dielectronic (1s 2 nl - 1s2pnl, with n greater than or equal to 2) satellites, of helium-like iron (Fe XXV) and titanium (Ti XXI). The satellite to resonance line ratios are very sensitive to the electron temperature and are used as an electron temperature diagnostic. The ion temperature is deduced from the Doppler width of the 1s - 2p resonance lines. The measurements have been performed with high resolution Bragg crystal spectrometers on the PLT (Princeton Large Torus) and PDX (Poloidal Divertor Experiment) tokamaks. The details of the experimental arrangement and line evaluation are described, and the ion and electron temperature results are compared with those obtained from independent diagnostic techniques, such as the analysis of charge-exchange neutrals and measurements of the electron cyclotron radiation. The obtained experimental results permit a detailed comparison with theoretical predictions

  12. PRODUCT PLACEMENT IN BRAND PROMOTION

    Directory of Open Access Journals (Sweden)

    Alicja Mikołajczyk

    2015-06-01

    Full Text Available Product placement can have a significant impact on brand awareness and customer purchasing decisions. The article discusses techniques applied in the mass media against the EU legal background and the opportunities it offers in reaching the target audience.

  13. Post-placement temperature reduction techniques

    DEFF Research Database (Denmark)

    Liu, Wei; Nannarelli, Alberto

    2010-01-01

    With technology scaled to deep submicron era, temperature and temperature gradient have emerged as important design criteria. We propose two post-placement techniques to reduce peak temperature by intelligently allocating whitespace in the hotspots. Both methods are fully compliant with commercial...

  14. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  15. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    International Nuclear Information System (INIS)

    Lee, Ye Jin; Kim, Jin Hyoung; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong

    2012-01-01

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10–119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  16. Observability-Based Guidance and Sensor Placement

    Science.gov (United States)

    Hinson, Brian T.

    Control system performance is highly dependent on the quality of sensor information available. In a growing number of applications, however, the control task must be accomplished with limited sensing capabilities. This thesis addresses these types of problems from a control-theoretic point-of-view, leveraging system nonlinearities to improve sensing performance. Using measures of observability as an information quality metric, guidance trajectories and sensor distributions are designed to improve the quality of sensor information. An observability-based sensor placement algorithm is developed to compute optimal sensor configurations for a general nonlinear system. The algorithm utilizes a simulation of the nonlinear system as the source of input data, and convex optimization provides a scalable solution method. The sensor placement algorithm is applied to a study of gyroscopic sensing in insect wings. The sensor placement algorithm reveals information-rich areas on flexible insect wings, and a comparison to biological data suggests that insect wings are capable of acting as gyroscopic sensors. An observability-based guidance framework is developed for robotic navigation with limited inertial sensing. Guidance trajectories and algorithms are developed for range-only and bearing-only navigation that improve navigation accuracy. Simulations and experiments with an underwater vehicle demonstrate that the observability measure allows tuning of the navigation uncertainty.

  17. Simulation training for pediatric residents on central venous catheter placement: a pilot study.

    Science.gov (United States)

    Thomas, Scott M; Burch, Wesley; Kuehnle, Sarah E; Flood, Robert G; Scalzo, Anthony J; Gerard, James M

    2013-11-01

    To assess the effect of simulation training on pediatric residents' acquisition and retention of central venous catheter insertion skills. A secondary objective was to assess the effect of simulation training on self-confidence to perform the procedure. Prospective observational pilot study. Single university clinical simulation center. Pediatric residents, postgraduate years 1-3. Residents participated in a 60- to 90-minute ultrasound-guided central venous catheter simulation training session. Video recordings of residents performing simulated femoral central venous catheter insertions were made before (baseline), after, and at 3-month following training. Three blinded expert raters independently scored the performances using a 24-item checklist and 100-mm global rating scale. At each time point, residents rated their confidence to perform the procedure on a 100-mm scale. Twenty-six residents completed the study. Compared with baseline, immediately following training, median checklist score (54.2% [interquartile range, 40.8-68.8%] vs 83.3% [interquartile range, 70.0-91.7%]), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 79.5 mm [interquartile range, 16.3-91.7 mm]), success rate (38.5% vs 80.8%), and self-confidence (8.0 mm [interquartile range, 3.8-19.0 mm] vs 52.0 mm [interquartile range, 43.5-66.5 mm]) all improved (p interquartile range, 40.8-68.8%] vs 54.2% [interquartile range, 45.8-80.4%], p = 0.47), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 35.5 mm [interquartile range, 5.3-77.0], p = 0.62), and success rate (38.5% vs 65.4%, p = 0.35) were similar at 3-month follow-up. Self-confidence, however, remained above baseline at 3-month follow-up (8.0 mm [interquartile range, 3.8-19.0 mm] vs 61.0 mm [interquartile range, 31.5-71.8 mm], p < 0.01). Simulation training improved pediatric residents' central venous catheter insertion procedural skills. Decay in skills was found at 3-month follow-up. This suggests that

  18. A new branch of advertising: reviewing factors that influence reactions to product placement

    NARCIS (Netherlands)

    van Reijmersdal, E.; Neijens, P.; Smit, E.G.

    2009-01-01

    This iiterature review presents a quantitative synthesis of 57 studies on product placement and shows which factors are most effective, it shows that placement characteristics, such as placement commerciality, modality, and prominence, have a strong impact on audience reactions. Audience

  19. Optimization of Placement Driven by the Cost of Wire Crossing

    National Research Council Canada - National Science Library

    Kapur, Nevin

    1997-01-01

    .... We implemented a prototype placement algorithm TOCO that minimizes the cost of wire crossing, and a universal unit-grid based placement evaluator place_eval. We have designed a number of statistical experiments to demonstrate the feasibility and the promise of the proposed approach.

  20. Outcomes assessment of science & engineering doctor of philosophy (Ph.D.) programs: An exploratory study of prospective influencers in distinguished graduate placement

    Science.gov (United States)

    Williamson, Louise M.

    This exploratory study was an investigation of the mission and emphases of twenty-two science & engineering doctor of philosophy (Ph.D.) programs in ten fields of study at nine public research universities in the United States and the corresponding influence those factors impose on placement of Ph.D. graduates of those programs into academic program settings. Ph.D. program chairs participated via protocol to provide descriptive, statistical, and experiential details of their Ph.D. programs and offered insight on current conditions for academic placement opportunities. The quantitative analysis served as the basis of examination of influencers in graduate placement for those Ph.D. programs that are informed about placement activity of their graduates. Among the nine tested hypotheses there were no statistically significant findings. The qualitative expressions of this study---those found in the confounding variables, the limitations of the study, those questions that elicited opinions and further discussion and follow-up queries with program chairs---added most meaningfully, however, to the study in that they served as a gauge of the implications of neglect for those Ph.D. programs that remain uninformed about their graduate placement activity. Central to the findings of this study was that one compelling fact remains the same. Denecke, Director of Best Practice at the Council of Graduate Schools, pointed out years ago that just as "we know very little about why those who finish and why those who leave do so, we also know surprisingly little about where students go after their degrees...we therefore have little information about how effective doctoral programs are in preparing doctorates for short- and long-term career success." The fact remains that the effectiveness of doctoral programs in the context of career success is just as uncertain today. A serious admonition is that one-half of those programs that participated in this study remain uninformed about the

  1. Is the Routine Check Nephrostogram Following Percutaneous Antegrade Ureteric Stent Placement Necessary?

    International Nuclear Information System (INIS)

    Soh, Keng Chuan; Tay, Kiang Hiong; Tan, Bien Soo; MM Htoo, Austin; HG Lo, Richard; Lin, Shueh En

    2008-01-01

    Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technical success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients

  2. [Family caregivers' adjustment to nursing home placement of older relatives].

    Science.gov (United States)

    Wang, Szu-Yao; Davies, Elizabeth

    2007-06-01

    The literature on the impact of nursing home placement of older parents on family caregivers is still incomplete. Family caregivers experience stress, shock, anxiety, fear, resistance, and guilt in the process of decision making. The literature has demonstrated that family caregivers continue to experience stress and problems after placing older relatives into a long term care facility. Cultural values impact on people's attitudes, values and expectations. Culture will therefore affect the care-giving experience. Relatively little information is available from Asian and multicultural societies. Identifying family caregiver experiences after nursing home placement can alert professionals to the need for family guidance prior to nursing home placement and assist in early identification of potential problems. This article reviews the literature and discusses the impact on family caregivers of making a decision for nursing home placement and dealing with the stress and challenges that persist after nursing home admission.

  3. Clinical placements and nursing students' career planning: a qualitative exploration.

    Science.gov (United States)

    McKenna, Lisa; McCall, Louise; Wray, Natalie

    2010-04-01

    Many nursing students enter undergraduate programmes with preconceived ideas about their future nursing careers, and intend to practice in particular areas such as midwifery or paediatrics. Through clinical placements, students are exposed to different clinical areas and professional socialization is facilitated. However, little is known about the influence of clinical placements on students' career intentions. This paper reports nursing findings drawn from a large qualitative study conducted in Victoria, Australia that sought to explore the influence of health professional students' clinical placements on their future career intentions. Participants were invited to be involved in either face-to-face or focus group interviews depending upon their own preference. Thematic data analysis revealed three main themes: 're-affirming career choice', 'working in a particular area' and 'work location'. Findings from the study add to our understanding of factors influencing nursing students' planning for their future careers including the impact of clinical placements.

  4. Mapping occipital bone thickness using computed tomography for safe screw placement.

    Science.gov (United States)

    Morita, Tomonori; Takebayashi, Tsuneo; Takashima, Hiroyuki; Yoshimoto, Mitsunori; Ida, Kazunori; Tanimoto, Katsumasa; Ohnishi, Hirofumi; Fujiwara, Hiroyoshi; Nagae, Masateru; Yamashita, Toshihiko

    2015-08-01

    OBJECT Safe and effective insertion of occipital bone screws requires morphological analysis of the occipital bone, which is poorly documented in the literature. The authors of this study present morphological data for determining the area of screw placement for optimal internal fixation. METHODS The subjects of this institutional review board-approved retrospective study were 105 individuals without head and neck disease who underwent CT imaging at the authors' hospital. There were 55 males and 50 females, with a mean age of 57.1 years (range 20-91 years). Measurements using CT were taken according to a matrix of 55 points following a grid with 1-cm spacing based on the external occipital protuberance (EOP). RESULTS The maximum thickness of the occipital bone was at the level of the EOP at 16.4 mm. Areas with thicknesses > 8 mm were more frequent at the EOP and up to 2 cm in all directions, as well as up to 1 cm in all directions at a height of 1 cm inferiorly, and up to 3 cm from the EOP inferiorly. The male group tended to have a thicker occipital bone than the female group, and the differences were significant around the EOP. The ratio of the trabecular bone to the occipital bone thickness was > 30% in the central region. At positions more than 2 cm laterally, the ratio was < 15%, and the ratio gradually decreased further laterally. CONCLUSIONS Screws that are 8 mm long can be placed in the area extending 2 cm laterally from the EOP at the level of the superior nuchal line and approximately 3 cm inferior to the center. These results suggest that it may be possible to effectively insert a screw over a wider area than the conventional reference range.

  5. Product Category Layout and Organization: Retail Placement of Food Products

    NARCIS (Netherlands)

    Herpen, van E.

    2016-01-01

    This article discusses the placement of food products in retail stores, in particular how the placement of food products can influence how consumers perceive the store in general and these products in particular. It reviews the overall layout of the store, assortment organization, and shelf

  6. [The implementation of Individual Placement and Support in the Netherlands].

    Science.gov (United States)

    Giesen, F; van Erp, N; van Weeghel, J; Michon, H; Kroon, H

    2007-01-01

    Individual Placement and Support is a vocational rehabilitation programme for people with severe mental illness, which was implemented during the period 2003-2005 at four locations in the Netherlands. To investigate the degree of compliance with the Individual Placement and Support programme, the factors that hindered or facilitated its implementation, and the results. The degree of compliance was assessed using the Individual Placement and Support fidelity scale. Data regarding the factors that hindered or facilitated the implementation were collected via interviews and monitoring. In addition, data were collected on patient characteristics, the support provided and the jobs found. None of the locations achieved the highest level of compliance, although two locations came close. Eighteen per cent of the 316 patients were helped to find a regular job. The most important obstacles to implementation were loss of vocational team members, project leaders' lack of time, lack of finance, and insufficient cooperation between the organisations involved. The most important facilitating factors were the skills and commitment of the vocational team member(s) and the integration of the vocational teammember(s) and the mental health team. It is not easy to implement Individual Placement and Support. However, if more attention is given to good project management, Individual Placement and Support can succeed in the Netherlands.

  7. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung; Lee, Yeoun Joo

    2013-01-01

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  8. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  9. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    International Nuclear Information System (INIS)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-01-01

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P   0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  10. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis.

    Science.gov (United States)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-08-01

    To evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis. We conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal. A total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P  0.05). Temporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  11. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  12. VARIABILITY PROMISING LINES PEANUT ON THE DRY LAND IN CENTRAL MALUKU DISTRICT

    Directory of Open Access Journals (Sweden)

    Sheny Kaihatu

    2013-01-01

    Full Text Available Study multiple strains or varieties of peanut aim to get two until three peanut promising lines (productivity larger three tons per ha of drought-tolerant Series of Dry Days larger than 15 percent and adaptive dryland agroecosystem in Maluku, performed in Central Maluku district Makariki 2010, using Randomized Block Design three replications. 10 strains planted include: S-4, S-5, S-8, S-9, S-10, S-11, S-15, S-16, S-19, S-20, and two varieties local Lions and Red as comparison. Wide swath of 2.5 m x 3.5 m, spacing of 40 cm x 15 cm, one seed per planting hole. Parameter: number of observations crop plants, 50 percent flowering, plant height, maturity, number of pods per plant, weight of wet pods per plant, dry weight of pods per plant, pod dry weight per plot, weight of 100 seeds (g and dry seed weight (tons per ha. Results: strains or varieties S-4 gives a wet pod weight and dry weight of pods per plant higher in amount of 62.2 g and 37.27 g where as strain S-5, S-11, and S-15 dry seed weight higher respectively by two tons per ha.

  13. Health professional students' rural placement satisfaction and rural practice intentions: A national cross-sectional survey.

    Science.gov (United States)

    Smith, Tony; Sutton, Keith; Pit, Sabrina; Muyambi, Kuda; Terry, Daniel; Farthing, Annie; Courtney, Claire; Cross, Merylin

    2018-02-01

    The aim of this study was to profile students undertaking placements at University Departments of Rural Health (UDRHs) and investigate factors affecting students' satisfaction and intention to enter rural practice. Cross-sectional survey comprising 21 core questions used by all UDRHs. Eleven UDRHs across Australia that support students' placements in regional, rural and remote locations. Medical, nursing and allied health students who participated in UDRH placements between July 2014 and November 2015 and completed the questionnaire. Key dependent variables were placement satisfaction and rural practice intention. Descriptive variables were age, gender, Aboriginal or Torres Strait Islander (ATSI) background, location of placement, healthcare discipline, year of study and type and length of placement. A total of 3328 students responded. The sample was predominantly female (79%), the mean age was 26.0 years and 1.8% identified as ATSI. Most placements (69%) were >2 but ≤12 weeks, 80% were in Modified Monash 3, 4 or 5 geographical locations. Public hospitals and community health made up 63% of placements. Students satisfied with their placement had 2.33 higher odds of rural practice intention. Those satisfied with Indigenous cultural training, workplace supervision, access to education resources and accommodation had higher odds of overall satisfaction and post-placement rural practice intention. The majority of students were highly satisfied with their placement and the support provided by rural clinicians and the UDRHs. UDRHs are well placed to provide health professional students with highly satisfactory placements that foster rural practice intention. © 2017 National Rural Health Alliance Inc.

  14. Distinguishing implicit from explicit brand attitudes in brand placement research

    NARCIS (Netherlands)

    Wennekers, A.M.; Vandeberg, L.; Zoon, K.; van Reijmersdal, E.A.; Verlegh, P.; Voorveld, H.; Eisend, M.

    2016-01-01

    Brand placement is a popular topic, both in business and academia. Brands are placed in a wide-ranging array of media, including television programs, movies, radio shows, magazines, games, music videos, and websites. Expenditures on brand placement are still growing (PQ Media, 2013), as well as the

  15. Retrograde or antegrade double-pigtail stent placement for malignant ureteric obstruction?

    International Nuclear Information System (INIS)

    Uthappa, M.C.; Cowan, N.C.

    2005-01-01

    AIM: To determine the optimum approach for double-pigtail stent placement in malignant ureteric obstruction. PATIENTS AND METHODS: Retrograde stent placement was attempted in a consecutive series of patients presenting with malignant ureteric obstruction. If retrograde stent placement was unsuccessful, percutaneous nephrostomy was performed immediately followed by elective antegrade stent placement. Identical digital C-arm fluoroscopy for image-guidance and conditions for anaesthesia and analgesia were employed for both retrograde and antegrade procedures. Identical 8 Fr (20-26 cm) double-pigtail hydrophilic coated stents were used for each approach. RESULTS: Retrograde placement was attempted in 50 ureters in 30 patients {19 male, 11 female, average age 61.4 yr (range 29-90 yr)} over a 24-month period. The success rate for retrograde ureteric stent placement was 50% (n=25/50). Technical failures were due to failure to identify the ureteric orifice (n=22), failure to cross the stricture (n=1), failure to pass the stent (n=1) and failure to pass a 4 Fr catheter (n=1). Antegrade placement was attempted in 25 ureters with a success rate of 96% (n=24/25). Failure in the one case was due to inability to cross an upper third stricture secondary to pyeloureteritis cystica. CONCLUSION: It is suggested that retrograde route should be the initial approach if imaging shows no involvement of ureteric orifice (UO), when nephrostomy is technically very difficult or in cases of solitary kidney. The antegrade route is preferred if imaging shows tumour occlusion of the UO or if there is a tight stricture very close to the uretero-vesical junction (UVJ) making purchase within the ureter difficult for crossing the stricture

  16. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  17. Efficient placement of structural dynamics sensors on the space station

    Science.gov (United States)

    Lepanto, Janet A.; Shepard, G. Dudley

    1987-01-01

    System identification of the space station dynamic model will require flight data from a finite number of judiciously placed sensors on it. The placement of structural dynamics sensors on the space station is a particularly challenging problem because the station will not be deployed in a single mission. Given that the build-up sequence and the final configuration for the space station are currently undetermined, a procedure for sensor placement was developed using the assembly flights 1 to 7 of the rephased dual keel space station as an example. The procedure presented approaches the problem of placing the sensors from an engineering, as opposed to a mathematical, point of view. In addition to locating a finite number of sensors, the procedure addresses the issues of unobserved structural modes, dominant structural modes, and the trade-offs involved in sensor placement for space station. This procedure for sensor placement will be applied to revised, and potentially more detailed, finite element models of the space station configuration and assembly sequence.

  18. Accounting for L2 learners’ errors in word stress placement

    Directory of Open Access Journals (Sweden)

    Clara Herlina Karjo

    2016-01-01

    Full Text Available Stress placement in English words is governed by highly complicated rules. Thus, assigning stress correctly in English words has been a challenging task for L2 learners, especially Indonesian learners since their L1 does not recognize such stress system. This study explores the production of English word stress by 30 university students. The method used for this study is immediate repetition task. Participants are instructed to identify the stress placement of 80 English words which are auditorily presented as stimuli and immediately repeat the words with correct stress placement. The objectives of this study are to find out whether English word stress placement is problematic for L2 learners and to investigate the phonological factors which account for these problems. Research reveals that L2 learners have different ability in producing the stress, but three-syllable words are more problematic than two-syllable words. Moreover, misplacement of stress is caused by, among others, the influence of vowel lenght and vowel height.

  19. Placement shift, sibling relationship quality, and child outcomes in foster care: a controlled study.

    Science.gov (United States)

    Linares, L Oriana; Li, MiMin; Shrout, Patrick E; Brody, Gene H; Pettit, Gregory S

    2007-12-01

    Sibling unity during family transitions is considered a protective factor for child behavior problems, but there is little empirical support for the widespread child protection policy of placing siblings together in foster care. In a prospective study of 156 maltreated children, siblings were classified in 1 of 3 placement groups: continuously together (n = 110), continuously apart (n = 22), and disrupted placement (siblings placed together were separated; n = 24). Changes in child adjustment as a function of sibling relationship and placement group were examined. Sibling positivity predicted lower child problems at follow-up (about 14 months later), while sibling negativity predicted higher child problems. Placement group did not affect child behavior problems at follow-up; however, compared to siblings in continuous placement (either together or apart), siblings in disrupted placement with high initial behavior problems were rated as having fewer problems at follow-up, while siblings in disrupted placement with low initial behavior problems were rated as having more problems at follow-up. These findings highlight the importance of considering relationships between siblings and the risk that one poses to another before early placement decisions are made.

  20. Intraoperative Factors that Predict the Successful Placement of Essure Microinserts.

    Science.gov (United States)

    Arthuis, Chloé J; Simon, Emmanuel G; Hébert, Thomas; Marret, Henri

    To determine whether the number of coils visualized in the uterotubal junction at the end of hysteroscopic microinsert placement predicts successful tubal occlusion. Cohort retrospective study (Canadian Task Force classification II-2). Department of obstetrics and gynecology in a teaching hospital. One hundred fifty-three women underwent tubal microinsert placement for permanent birth control from 2010 through 2014. The local institutional review board approved this study. Three-dimensional transvaginal ultrasound (3D TVU) was routinely performed 3 months after hysteroscopic microinsert placement to check position in the fallopian tube. The correlation between the number of coils visible at the uterotubal junction at the end of the hysteroscopic microinsert placement procedure and the device position on the 3-month follow-up 3D TVU in 141 patients was evaluated. The analysis included 276 microinserts placed during hysteroscopy. The median number of coils visible after the hysteroscopic procedure was 4 (interquartile range, 3-5). Devices for 30 patients (21.3%) were incorrectly positioned according to the 3-month follow-up 3D TVU, and hysterosalpingography was recommended. In those patients the median number of coils was in both the right (interquartile range, 2-4) and left (interquartile range, 1-3) uterotubal junctions. The number of coils visible at the uterotubal junction at the end of the placement procedure was the only factor that predicted whether the microinsert was well positioned at the 3-month 3D TVU confirmation (odds ratio, .44; 95% confidence interval, .28-.63). When 5 or more coils were visible, no incorrectly placed microinsert could be seen on the follow-up 3D TVU; the negative predictive value was 100%. No pregnancies were reported. The number of coils observed at the uterotubal junction at the time of microinsert placement should be considered a significant predictive factor of accurate and successful microinsert placement. Copyright © 2017

  1. Occupational therapy students' contribution to occasions of service during practice placements in health settings.

    Science.gov (United States)

    Rodger, Sylvia; Stephens, Elizabeth; Clark, Michele; Ash, Susan; Graves, Nicholas

    2011-12-01

    Currently in the Australian higher education sector, the productivity benefits of occupational therapy clinical education placements are a contested issue. This article will report results of a study that developed a methodology for documenting time use during placements and investigated the productivity changes associated with occupational therapy clinical education placements in Queensland, Australia. Supervisors' and students' time use during placements and how this changed for supervisors compared to pre- and post-placement is also presented. Using a cohort survey design, participants were students from two Queensland universities, and their supervisors employed by Queensland Health. Time use was recorded in 30 minute blocks according to particular categories. There was a significant increase in supervisors' time spent in patient care activities (F = 94.011(2,12.37 df) , P increasing between pre- and during placement (P = 0.028). There was a significant decrease in supervisors' time spent in placement activities (F = 5.133(2,19.18 df) , P = 0.016) from during to post-placement. Students spent more time than supervisors in patient care activities while on placement. A novel method for reporting productivity and time-use changes during clinical education programs for occupational therapy has been applied. Supervisors spent considerable time in assessing and managing students and their clinical education role should be seen as core business in standard occupational therapy practice. This paper will contribute to future assessments of the economic impact of student placements for allied health disciplines. © 2011 The Authors. Australian Occupational Therapy Journal © 2011 Occupational Therapy Australia.

  2. Speeding Up FPGA Placement via Partitioning and Multithreading

    Directory of Open Access Journals (Sweden)

    Cristinel Ababei

    2009-01-01

    placement subproblems are created by partitioning and then processed concurrently by multiple worker threads that are run on multiple cores of the same processor. Our main goal is to investigate the speedup that can be achieved with this simple approach compared to previous approaches that were based on distributed computing. The new hybrid parallel placement algorithm achieves an average speedup of 2.5× using four worker threads, while the total wire length and circuit delay after routing are minimally degraded.

  3. 37 CFR 211.6 - Methods of affixation and placement of mask work notice.

    Science.gov (United States)

    2010-07-01

    ... placement of mask work notice. 211.6 Section 211.6 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.6 Methods of affixation and placement of mask work notice. (a) General. (1) This section specifies methods of affixation and placement...

  4. Volunteering and overseas placements in the NHS: a survey of current activity.

    Science.gov (United States)

    Chatwin, John; Ackers, Louise

    2016-10-19

    The study aimed to establish current levels of overseas volunteering and placement activity across all staff grades within the National Health Service (NHS) in the North West of England. Cross-sectional survey. Descriptive statistics. 4 main regional hospitals in the North West of England, and additional NHS staff training events. Convenience sample of NHS staff (n=911). 911 NHS staff took part in the survey. The medical and dental staff group returned the highest number of responses (32.1%). 42% of staff reported some form of overseas volunteering or placement experience. Most staff took an international placement as students (33.6% men; 40.6% women). Medium-term placements were undertaken by 46.7% of men, and 52.5% of women. Settlement stays (ie, over 1 year) were reported by 7.6% men, and 8.3% women). The majority of respondents engaged in international placement were from the age groups incorporating 'below 25' to '41-50' (74%). Multiple placement experiences were uncommon: 2.5% of respondents reported three periods of overseas activity, and 1.5% reported four. All those with multiple placement experience came from the staff groups incorporating midwife/nurse/health visitor, and medical and dental. This survey captured a snapshot of current levels of volunteering and overseas placement activity across NHS staff grades in the North West. Owing to relatively homogenous organisational structures, findings are likely to broadly represent the position across the organisation as a whole. Although some degree of overseas placement activity is undertaken by a relatively high proportion of NHS staff, such activity is currently heavily skewed towards higher clinical staff grades. Significant numbers of allied health professionals and equivalent non-clinical cadres also report overseas experience, and we anticipate that the numbers will continue to rise if current policy initiatives gain momentum. Published by the BMJ Publishing Group Limited. For permission to use

  5. Selective Placement Program Coordinator (SPPC) Directory

    Data.gov (United States)

    Office of Personnel Management — List of the Selective Placement Program Coordinators (SPPC) in Federal agencies, updated as needed. Users can filter the list by choosing a state and/or agency name.

  6. Mode of communication and classroom placement impact on speech intelligibility.

    Science.gov (United States)

    Tobey, Emily A; Rekart, Deborah; Buckley, Kristi; Geers, Ann E

    2004-05-01

    To examine the impact of classroom placement and mode of communication on speech intelligibility scores in children aged 8 to 9 years using multichannel cochlear implants. Classroom placement (special education, partial mainstream, and full mainstream) and mode of communication (total communication and auditory-oral) reported via parental rating scales before and 4 times after implantation were the independent variables. Speech intelligibility scores obtained at 8 to 9 years of age were the dependent variables. The study included 131 congenitally deafened children between the ages of 8 and 9 years who received a multichannel cochlear implant before the age of 5 years. Higher speech intelligibility scores at 8 to 9 years of age were significantly associated with enrollment in auditory-oral programs rather than enrollment in total communication programs, regardless of when the mode of communication was used (before or after implantation). Speech intelligibility at 8 to 9 years of age was not significantly influenced by classroom placement before implantation, regardless of mode of communication. After implantation, however, there were significant associations between classroom placement and speech intelligibility scores at 8 to 9 years of age. Higher speech intelligibility scores at 8 to 9 years of age were associated with classroom exposure to normal-hearing peers in full or partial mainstream placements than in self-contained, special education placements. Higher speech intelligibility scores in 8- to 9-year-old congenitally deafened cochlear implant recipients were associated with educational settings that emphasize oral communication development. Educational environments that incorporate exposure to normal-hearing peers were also associated with higher speech intelligibility scores at 8 to 9 years of age.

  7. Substantial changes in mastery perceptions of dementia caregivers with the placement of a care recipient.

    Science.gov (United States)

    Infurna, Frank J; Gerstorf, Denis; Zarit, Steven H

    2013-03-01

    The current study examined how a key component of caregiving stress processes, global mastery perceptions, changes with placing the care recipient in a nursing home or institution. We also explored the role of primary stressors in accounting for mastery changes with placement and whether characteristics of the caregiver and care recipient moderate reactions to placement. We applied multiphase growth curve models to prospective longitudinal data from 271 caregivers in the Caregiver Stress and Coping Study who experienced placement of their care recipient. Using a time-to/from-placement metric, we found that caregivers typically experienced declines in mastery preceding placement, followed by a significant increase within 1 year after placement and further increases thereafter. Corresponding changes in primary stressors (role overload) mediated the placement-related increase in mastery. Caregivers who reported more depressive symptoms and activities of daily living/instrumental activities of daily living dependencies of the care recipient were more likely to experience larger placement-related increases in mastery perceptions. Our findings suggest that placement alters psychological resources of caregivers and this effect is driven by corresponding changes in primary stressors. Findings also underscore the importance of examining change processes across salient life events and transitions.

  8. Teaching teamwork: an evaluation of an interprofessional training ward placement for health care students

    Directory of Open Access Journals (Sweden)

    Morphet J

    2014-06-01

    Full Text Available Julia Morphet,1 Kerry Hood,2 Robyn Cant,2 Julie Baulch,3 Alana Gilbee,3 Kate Sandry4 1School of Nursing and Midwifery, Monash University, Frankston, Victoria, Australia; 2School of Nursing and Midwifery, Monash University, Clayton, Victoria, Australia; 3Southern Clinical School, Monash University, Monash Health, Clayton, Victoria, Australia; 4Dandenong Emergency Department, Monash Health, David St, Dandenong, Victoria, Australia Abstract: The establishment of interprofessional teamwork training in the preprofessional health care curriculum is a major challenge for teaching faculties. Interprofessional clinical placements offer an opportunity for teamwork education, as students in various professions can work and learn together. In this sequential, mixed-method study, focus group and survey techniques were used to evaluate students' educational experiences after 2-week ward-based interprofessional clinical placements. Forty-five senior nursing, medicine, and other health care students cared for patients in hospital wards under professional supervision, with nursing-medicine student "teams" leading care. Thirty-six students attended nine exit focus groups. Five central themes that emerged about training were student autonomy and workload, understanding of other professional roles, communication and shared knowledge, interprofessional teamwork/collaboration, and the "inner circle", or being part of the unit team. The learning environment was described as positive. In a postplacement satisfaction survey (n=38, students likewise rated the educational experience highly. In practicing teamwork and collaboration, students were able to rehearse their future professional role. We suggest that interprofessional clinical placements be regarded as an essential learning experience for senior preprofessional students. More work is needed to fully understand the effect of this interactive program on students' clinical learning and preparation for practice

  9. Private Placements as Sources of Long Term Funds for publicly ...

    African Journals Online (AJOL)

    Thereafter, an overview of the concept of private placement is given to enable a better appreciation of its unique role in raising funds for organizations that are not publicly quoted in a registered stock exchange. It concludes with an exposition of the problems of allowing private placements for publicly quoted firms.

  10. Advanced Placement U.S. History: What Happens after the Examination?

    Science.gov (United States)

    Henry, Michael

    1991-01-01

    Discusses a survey of 56 advanced placement (AP) U.S. history teachers. Explores the scope of AP history and types of posttest activities used after Advanced Placement examinations. Concludes that public school courses developed more deeply into post-1960 events than the private schools did. Describes movies, debates, simulations, and local…

  11. Evaluating the accuracy of sampling to estimate central line-days: simplification of the National Healthcare Safety Network surveillance methods.

    Science.gov (United States)

    Thompson, Nicola D; Edwards, Jonathan R; Bamberg, Wendy; Beldavs, Zintars G; Dumyati, Ghinwa; Godine, Deborah; Maloney, Meghan; Kainer, Marion; Ray, Susan; Thompson, Deborah; Wilson, Lucy; Magill, Shelley S

    2013-03-01

    To evaluate the accuracy of weekly sampling of central line-associated bloodstream infection (CLABSI) denominator data to estimate central line-days (CLDs). Obtained CLABSI denominator logs showing daily counts of patient-days and CLD for 6-12 consecutive months from participants and CLABSI numerators and facility and location characteristics from the National Healthcare Safety Network (NHSN). Convenience sample of 119 inpatient locations in 63 acute care facilities within 9 states participating in the Emerging Infections Program. Actual CLD and estimated CLD obtained from sampling denominator data on all single-day and 2-day (day-pair) samples were compared by assessing the distributions of the CLD percentage error. Facility and location characteristics associated with increased precision of estimated CLD were assessed. The impact of using estimated CLD to calculate CLABSI rates was evaluated by measuring the change in CLABSI decile ranking. The distribution of CLD percentage error varied by the day and number of days sampled. On average, day-pair samples provided more accurate estimates than did single-day samples. For several day-pair samples, approximately 90% of locations had CLD percentage error of less than or equal to ±5%. A lower number of CLD per month was most significantly associated with poor precision in estimated CLD. Most locations experienced no change in CLABSI decile ranking, and no location's CLABSI ranking changed by more than 2 deciles. Sampling to obtain estimated CLD is a valid alternative to daily data collection for a large proportion of locations. Development of a sampling guideline for NHSN users is underway.

  12. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    Science.gov (United States)

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  13. Product placement in Hollywood blockbusters: brand recognition and attitude towards the practice : A case study on product placement attitudes among international students

    OpenAIRE

    Tiavin, Kiril; Köllisch, Frederic; Nurminen, Vili

    2015-01-01

    Background: Advertising channels in today's marketplace are becoming more limited with the development of ad-free sources of entertainment. The phenomenon of product placements is therefore becoming one of the most important sources for advertising in media. Especially film productions have turned into a canvas for companies to display their brands upon. Purpose: The purpose of this thesis was to investigate the case of product placements in Hollywood blockbuster movies. In particular, brand ...

  14. Restrictive educational placements increase adolescent risks for students with early-starting conduct problems.

    Science.gov (United States)

    Powers, Christopher J; Bierman, Karen L; Coffman, Donna L

    2016-08-01

    Students with early-starting conduct problems often do poorly in school; they are disproportionately placed in restrictive educational placements outside of mainstream classrooms. Although intended to benefit students, research suggests that restrictive placements may exacerbate the maladjustment of youth with conduct problems. Mixed findings, small samples, and flawed designs limit the utility of existing research. This study examined the impact of restrictive educational placements on three adolescent outcomes (high school noncompletion, conduct disorder, depressive symptoms) in a sample of 861 students with early-starting conduct problems followed longitudinally from kindergarten (age 5-6). Causal modeling with propensity scores was used to adjust for confounding factors associated with restrictive placements. Analyses explored the timing of placement (elementary vs. secondary school) and moderation of impact by initial problem severity. Restrictive educational placement in secondary school (but not in elementary school) was iatrogenic, increasing the risk of high school noncompletion and the severity of adolescent conduct disorder. Negative effects were amplified for students with conduct problem behavior with less cognitive impairment. To avoid harm to students and to society, schools must find alternatives to restrictive placements for students with conduct problems in secondary school, particularly when these students do not have cognitive impairments that might warrant specialized educational supports. © 2015 Association for Child and Adolescent Mental Health.

  15. 25 CFR 26.11 - What type of Job Placement and Training assistance may be approved?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What type of Job Placement and Training assistance may be... JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.11 What type of Job Placement and... supplemental assistance that supports job placement or training activities (see subpart B of this part for Job...

  16. Does antibiotic prophylaxis at implant placement decrease early implant failures? A Cochrane systematic review.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Loli, Vasiliki; Coulthard, Paul; Worthington, Helen V

    2010-01-01

    Marco Esposito is the first author of two of the included studies; however, he was not involved in the quality assessment of these trials. This review is based on a Cochrane systematic review entitled 'Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications' published in The Cochrane Library (see http://www.cochrane.org for more information). Cochrane systematic reviews are regularly updated to include new research, and in response to comments and criticisms from readers. If you wish to comment on this review, please send your comments to the Cochrane website or to Marco Esposito. The Cochrane Library should be consulted for the most recent version of the review. The results of a Cochrane Review can be interpreted differently, depending on people's perspectives and circumstances. Please consider the conclusions presented carefully. They are the opinions of the review authors, and are not necessarily shared by the Cochrane Collaboration. To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched up to 2 June 2010 for randomised controlled clinical trials (RCTs) with a follow-up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted in duplicate and independently by two review authors. Meta-analyses were

  17. A shared experience of fragmentation: making sense of foster placement breakdown.

    Science.gov (United States)

    Rostill-Brookes, Helen; Larkin, Michael; Toms, Amy; Churchman, Clare

    2011-01-01

    Multiple placement transitions have been associated with poorer psychosocial outcomes for children growing up in local authority care. However, although there is an expanding literature examining the risk and protective factors connected with placement breakdown, very few studies have explored the quality of the move experience for those most closely involved with it. Our study considered how young people, foster carers and social workers made sense of unplanned placements' endings. Bringing together the lived experiences of these key stakeholders in the placement system added a novel dimension to existing research knowledge. What emerged from our analysis was evidence of a pervasive and shared emotional experience; all of the participants were affected by the breakdown irrespective of age, experience, or professional role. However, despite many commonalities, there was also a strong sense of fragmentation between the groups, which was characterised by discourses of mistrust and miscommunication. This meant that emotional reactions to the breakdown were often suppressed or dismissed, resentments built-up and attempts to find a solution were thwarted by silence or angry recrimination. These findings raise real challenges for practice and policy development. In particular, they stress the importance of shared and meaningful dialogue between all key stakeholders within the social care system, the need for more effective and timely support when placements are in crisis and opportunities for those most closely involved with the placement breakdown to process the emotional experience.

  18. Making short-term international medical volunteer placements work: a qualitative study.

    Science.gov (United States)

    Elnawawy, Omnia; Lee, Andrew C K; Pohl, Gerda

    2014-06-01

    International medical volunteering has grown in recent decades. It has the potential to benefit and harm the volunteer and host countries; but there is a paucity of literature on the impacts of international medical volunteering and a need to find ways to optimise the benefits of such placements. In this study, one example of international medical volunteering was examined involving British GPs on short-term placements in Nepal. The intention was to explore the expectations and experiences of the local health workers, volunteers, and host organisation to try and understand what makes volunteer placements work. Qualitative study of key informant interviews. Stakeholders of a short-term international medical volunteer (IMV) placement programme in Nepal. Key informant interviews were carried out via face-to-face or telephone/internet interviews with five previous volunteers, three representatives from a non-governmental organisation providing placements, and five local health workers in Nepal who had had contact with the IMVs. Interviews were recorded, transcribed, and analysed using standard thematic framework approaches. All the stakeholders had their own specific motives for participating in the IMV programme. The relationship between volunteers and the Nepalese health workers was complex and characterised by discrepant and occasionally unrealistic expectations. Managing these different expectations was challenging. Contextual issues and cultural differences are important considerations in medical volunteer programmes, and this study highlights the importance of robust preparation pre-placement for the volunteer and host to ensure positive outcomes. © British Journal of General Practice 2014.

  19. Radiography students' clinical placement experiences in MRI: A phenomenological study

    International Nuclear Information System (INIS)

    Portanier Mifsud, Claude; Castillo, Joseph; Portelli, Jonathan Loui

    2015-01-01

    Purpose: The purpose of this study was to gain an insight into radiography students' clinical practice experiences within an MRI unit of a large teaching hospital in Malta. The underlying objectives of the study were to identify and explore the descriptions and meanings of the MRI clinical experiences of students. Methods: Five students, independently undergoing their clinical placements in MRI were asked to write a diary about their daily experiences. Each student then participated in a follow up interview. Data analysis was based on Husserls' phenomenological approach. Results: Eight themes emerged from the data analysed. Students described their experience as one mainly based on observation, where, during their placements, they observed radiographers at work. In this respect, students described their experience as lacking ‘hands on practice’. Students indicated that they felt uncomfortable, unsupervised and unwelcome most of the time. They also expressed the need to feel useful and part of the MRI team during their placement and so they tried to help the team in areas such as patient screening. This helped them build confidence. Learning in MRI was specifically based on the university tasks prescribed and possibly there was no motivation to learn more. The students also described their experience as varied and different when compared to other placements. Conclusion: This study provides a rare insight into radiography students' placement experiences in MRI and should enable the supervising radiographer and educator to obtain a deeper appreciation of the clinical placement experience

  20. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  1. Something has shifted: Nursing students' global perspective following international clinical placements.

    Science.gov (United States)

    Gower, Shelley; Duggan, Ravani; Dantas, Jaya A R; Boldy, Duncan

    2017-10-01

    To examine understandings of global health issues among nursing students following participation in an international clinical placement during their pre-registration university education. Universities use international clinical placements, especially in developing countries, to develop cultural awareness in students; however, little is known about the longer term influences on students' understandings of global nursing. A retrospective cross-sectional design was used, using an exploratory, descriptive qualitative approach. Individual semi-structured interviews were conducted in 2014 with a purposive sample of 25 pre-registration nursing students from four Western Australian universities who undertook clinical placements across five countries. Data were analysed using inductive thematic analysis. Findings highlight that students developed new understandings around health systems including fragility of resource access, differences in clinical practice and variances in nursing roles between settings. Students also experienced challenges but were able to appreciate alternative world viewpoints. International clinical placements can develop greater awareness and help students form realistic strategies for using their nursing skills globally. Pre-placement training in cultural awareness and health system realities, along with strong supervisory support, is critical to success. © 2017 John Wiley & Sons Ltd.

  2. Placement Evaluations and Remedial Education: Are Students Shopping for Bargains?

    Science.gov (United States)

    Fletcher, Stephen H.

    2014-01-01

    The purpose of this study is to provide evidence that students may be doing comparison shopping when it comes to community college placement in English and mathematics courses. Comparisons may occur because of the difference in the placement process across campuses and the variation in the levels of developmental education offered. The…

  3. 34 CFR 300.325 - Private school placements by public agencies.

    Science.gov (United States)

    2010-07-01

    ... Programs, and Educational Placements Development of Iep § 300.325 Private school placements by public... child to, a private school or facility, the agency must initiate and conduct a meeting to develop an IEP... disability enters a private school or facility, any meetings to review and revise the child's IEP may be...

  4. 25 CFR 26.3 - What is the purpose of the Job Placement and Training Program?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What is the purpose of the Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.3 What is the purpose of the Job Placement and Training Program? The purpose of the Job Placement and Training Program is to assist eligible applicants to...

  5. Wavelength converter placement for different RWA algorithms in wavelength-routed all-optical networks

    Science.gov (United States)

    Chu, Xiaowen; Li, Bo; Chlamtac, Imrich

    2002-07-01

    Sparse wavelength conversion and appropriate routing and wavelength assignment (RWA) algorithms are the two key factors in improving the blocking performance in wavelength-routed all-optical networks. It has been shown that the optimal placement of a limited number of wavelength converters in an arbitrary mesh network is an NP complete problem. There have been various heuristic algorithms proposed in the literature, in which most of them assume that a static routing and random wavelength assignment RWA algorithm is employed. However, the existing work shows that fixed-alternate routing and dynamic routing RWA algorithms can achieve much better blocking performance. Our study in this paper further demonstrates that the wavelength converter placement and RWA algorithms are closely related in the sense that a well designed wavelength converter placement mechanism for a particular RWA algorithm might not work well with a different RWA algorithm. Therefore, the wavelength converter placement and the RWA have to be considered jointly. The objective of this paper is to investigate the wavelength converter placement problem under fixed-alternate routing algorithm and least-loaded routing algorithm. Under the fixed-alternate routing algorithm, we propose a heuristic algorithm called Minimum Blocking Probability First (MBPF) algorithm for wavelength converter placement. Under the least-loaded routing algorithm, we propose a heuristic converter placement algorithm called Weighted Maximum Segment Length (WMSL) algorithm. The objective of the converter placement algorithm is to minimize the overall blocking probability. Extensive simulation studies have been carried out over three typical mesh networks, including the 14-node NSFNET, 19-node EON and 38-node CTNET. We observe that the proposed algorithms not only outperform existing wavelength converter placement algorithms by a large margin, but they also can achieve almost the same performance comparing with full wavelength

  6. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  7. Commercialization and marketing of non-wood forest products in Central Serbia

    Directory of Open Access Journals (Sweden)

    Keča Ljiljana

    2013-01-01

    Full Text Available The phenomenon of return to nature and its original values is increasingly common worldwide in accordance with the principles of sustainable development. In this context, it is particularly important to pay attention to organic products, as well as the increased demand for healthy food. In these circumstances non-wood forest products (NWFPs emerge as forestry products that meet the criteria of organic farming and as such are placed on the market. The aim of this research was to acquire knowledge about the behavior of the marketing mix elements of NWFPs in Central Serbia in the period from 2007 to 2011. The purpose of this paper was to point to the opportunities for the development of enterprises, and the overall potential of Serbia for the development of companies engaged in purchasing, processing and placement of NWFPs. The research object were the quantities of products purchased and placed on both domestic and foreign markets, the types of promotional activities, the prices of final products and distribution of the products among the enterprises engaged in purchasing, processing and placement of NWFPs in Central Serbia. [Projekat Ministarstva nauke Republike Srbije, br. 37008: Održivo gazdovanje ukupnim potencijalima šuma u Republici Srbiji

  8. This is advertising! Effects of disclosing television brand placement on adolescents

    NARCIS (Netherlands)

    Reijmersdal, E.A. van; Boerman, S.C.; Buijzen, M.A.; Rozendaal, E.

    2017-01-01

    As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing

  9. This is Advertising! Effects of Disclosing Television Brand Placement on Adolescents

    NARCIS (Netherlands)

    van Reijmersdal, E.A.; Boerman, S.C.; Buijzen, M.; Rozendaal, E.

    As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing

  10. Can double-peaked lines indicate merging effects in AGNs?

    Directory of Open Access Journals (Sweden)

    Popović L.Č.

    2000-01-01

    Full Text Available The influence of merging effects in the central part of an Active Galactic Nucleus (AGN on the emission spectral line shapes are discussed. We present a model of close binary Broad Line Region. The numerical experiments show that the merging effects can explain double peaked lines. The merging effects may also be present in the center of AGNs, although they emit slightly asymmetric as well as symmetric and relatively stable (in profile shape spectral lines. Depending on the black hole masses and their orbit elements such model may explain some of the line profile shapes observed in AGNs. This work shows that if one is looking for the merging effects in the central region as well as in the wide field structure of AGNs, he should first pay attention to objects which have double peaked lines.

  11. The hand hygiene compliance of student nurses during clinical placements.

    Science.gov (United States)

    Sundal, Jorun Saetre; Aune, Anne Grethe; Storvig, Eline; Aasland, Jenny Kristin; Fjeldsaeter, Kaja Linn; Torjuul, Kirsti

    2017-12-01

    To observe student nurses' overall and moment-specific hand hygiene compliance during clinical placement. Hand hygiene is the single most important measure to prevent healthcare-associated infections. However, research has shown low compliance among healthcare workers. During clinical placements, student nurses perform various nursing tasks and procedures to a large number of patients, requiring extensive patient contact. It is crucial that they practice correct hand hygiene to prevent healthcare-associated infections. Open, standardised and nonparticipating observations. Twenty-nine student nurses were observed three times for 20 ± 10 min during clinical placement in a Norwegian university hospital. To measure compliance, we used WHO's Hand Hygiene Observation tool, based on the model "My five moments for hand hygiene". Overall hand hygiene compliance in the student group was 83.5%. Highest moment-specific compliance was after touching patient surroundings, after touching patients and after body fluid exposure risk. Lowest moment-specific compliance was recorded before touching patients or patient surroundings, and before clean/aseptic procedures. Nurse education needs to be improved both theoretically and during clinical placements in order to advance and sustain compliance among student nurses. Increasing healthcare workers' compliance with hand hygiene guidelines remains a challenge to the clinical community. In order to reduce healthcare-associated infections, it is important to educate student nurses to comply with the guidelines during clinical placements. Identifying student nurses' hand hygiene performance is the first step towards developing teaching methods to improve and sustain their overall and moment-specific compliance. As a measure to ensure student compliance during clinical placements, mentors should be aware of their influence on students' performance, act as hand hygiene ambassadors, encourage students to comply with established guidelines

  12. Shaping children's healthy eating habits with food placements? Food placements of high and low nutritional value in cartoons, Children's BMI, food-related parental mediation strategies, and food choice.

    Science.gov (United States)

    Naderer, Brigitte; Matthes, Jörg; Binder, Alice; Marquart, Franziska; Mayrhofer, Mira; Obereder, Agnes; Spielvogel, Ines

    2018-01-01

    Research on media induced food choices of children has not sufficiently investigated whether food placements of snacks high in nutritional value can strengthen children's healthy eating behavior. Furthermore, we lack knowledge about the moderating role of children's individual characteristics such as parental food-related mediation or BMI. The current study combines data from an experiment involving children with a survey of their parents. We exposed children to a cartoon either containing no food placements, placements of mandarins (i.e., snack high in nutritional value), or placements of fruit gums (i.e., snack low in nutritional value). Afterwards, food consumption was measured by giving children the option to choose between fruit gums or mandarins. Children in both snack placement conditions showed stronger preference for the snack low in nutritional value (i.e., fruit gum) compared to the control group. Interestingly, neither restrictive nor active food-related mediation prevented the effects of the placements on children's choice of snacks low in nutritional value. Compared to children with a low BMI, children with high BMI levels had a stronger disposition to choose the fruit gums if a snack high in nutritional value (i.e., mandarin) was presented. Thus, making snacks high in nutritional attractive for children through media presentation might need stronger persuasive cues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. 25 CFR 26.5 - Who may be eligible for Job Placement and Training?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who may be eligible for Job Placement and Training? 26.5 Section 26.5 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.5 Who may be eligible for Job Placement and Training? You may...

  14. Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.

    Science.gov (United States)

    Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-04-01

    To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  15. Unilateral placement of the Adiana device after failed bilateral placement of the Essure device for hysteroscopic sterilization.

    Science.gov (United States)

    Gimpelson, Richard J; Wagner, Corey A

    2010-01-01

    This case report outlines the successful completion of hysteroscopic sterilization using the Adiana Permanent Contraception device (Hologic, Inc., Bedford, MA) after failure of multiple attempts to bilaterally place the Essure Permanent Birth Control system (Conceptus Inc., Mountain View, CA). The patient desired hysteroscopic sterilization using the Essure system. Although the first coil was easily placed in the right ostium, the second coil could not be passed beyond 2.4 cm into the left ostium. Inasmuch as the Adiana system needs to be passed only 1.4 cm into the ostium, this was found to be adequate for appropriate placement of the implant. Adiana may be an effective alternative to Essure, especially in patients in whom tubal stricture or spasm prevents Essure placement. Copyright © 2010 AAGL. Published by Elsevier Inc. All rights reserved.

  16. Role of ultrasound for central catheter tip localization in neonates: a review of the current evidence.

    Science.gov (United States)

    Sharma, Deepak; Farahbakhsh, Nazanin; Tabatabaii, Seyyed Ahmad

    2018-02-15

    Central catheters are known as "life lines" in intensive care units and are used frequently in neonatal intensive care unit (NICU) for multiple indications. The central catheters used in NICU includes umbilical venous catheter (UVC), umbilical arterial catheter (UAC) and peripherally inserted central catheter (PICC) lines. The tip of these central lines needs to be in a correct position as malpositioned central line tips lead to many neonatal complications. Radiograph either abdomen or chest is the most widely used modality for locating the tip of the central catheter. There are many disadvantages of radiographic confirmation of tip position and recently ultrasound (USG)/echocardiography has been used for localization of catheter tip. USG provides real-time assessment of the tip position with other added advantages like no radiation exposure, need for minimal training for performing USG, minimal handling of the neonate, identification of migration of central lines and making repositioning of central lines under USG guidance. The present evidence supports the use of USG/Echo for localization of central catheter tip and USG has shown to have good sensitivity, specificity, positive predictive value and negative predictive value when compared with a radiograph. In this review, we discuss about the role of USG/Echo in the identification of tip of central catheters in neonatal care.

  17. 34 CFR 300.116 - Placements.

    Science.gov (United States)

    2010-07-01

    ... educational placement of a child with a disability, including a preschool child with a disability, each public... with a disability requires some other arrangement, the child is educated in the school that he or she... modifications in the general education curriculum. (Approved by the Office of Management and Budget under...

  18. Optimal PMU Placement By Improved Particle Swarm Optimization

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Liu, Leo; Chen, Zhe

    2013-01-01

    This paper presents an improved method of binary particle swarm optimization (IBPSO) technique for optimal phasor measurement unit (PMU) placement in a power network for complete system observability. Various effective improvements have been proposed to enhance the efficiency and convergence rate...... of conventional particle swarm optimization method. The proposed method of IBPSO ensures optimal PMU placement with and without consideration of zero injection measurements. The proposed method has been applied to standard test systems like 17 bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus system...

  19. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  20. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  1. PD2P : PanDA Dynamic Data Placement for ATLAS

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The PanDA Dynamic Data Placement (PD2P) system has been developed to cope with difficulties of data placement for ATLAS. PD2P is an intelligent subsystem of PanDA to distribute data by taking the following factors into account: popularity, locality, the usage pattern of the data, the distribution of CPU and storage resources, ...

  2. Placements: An Underused Vehicle for Quality Enhancement in Higher Education?

    Science.gov (United States)

    Kettis, Asa; Ring, Lena; Gustavsson, Maria; Wallman, Andy

    2013-01-01

    Placements have the potential to contribute more effectively to the quality of higher education. The aim of this article is to discuss how placements can be made more worthwhile for individual students, while also contributing to the overall quality of teaching and learning at HEIs as well as to the development of workplace cultures that are…

  3. College Math Assessment: SAT Scores vs. College Math Placement Scores

    Science.gov (United States)

    Foley-Peres, Kathleen; Poirier, Dawn

    2008-01-01

    Many colleges and university's use SAT math scores or math placement tests to place students in the appropriate math course. This study compares the use of math placement scores and SAT scores for 188 freshman students. The student's grades and faculty observations were analyzed to determine if the SAT scores and/or college math assessment scores…

  4. Analog integrated circuit design automation placement, routing and parasitic extraction techniques

    CERN Document Server

    Martins, Ricardo; Horta, Nuno

    2017-01-01

    This book introduces readers to a variety of tools for analog layout design automation. After discussing the placement and routing problem in electronic design automation (EDA), the authors overview a variety of automatic layout generation tools, as well as the most recent advances in analog layout-aware circuit sizing. The discussion includes different methods for automatic placement (a template-based Placer and an optimization-based Placer), a fully-automatic Router and an empirical-based Parasitic Extractor. The concepts and algorithms of all the modules are thoroughly described, enabling readers to reproduce the methodologies, improve the quality of their designs, or use them as starting point for a new tool. All the methods described are applied to practical examples for a 130nm design process, as well as placement and routing benchmark sets. Introduces readers to hierarchical combination of Pareto fronts of placements; Presents electromigration-aware routing with multilayer multiport terminal structures...

  5. The experiences of student nurses on placements with practice nurses: A pilot study.

    Science.gov (United States)

    Gale, Julia; Ooms, Ann; Sharples, Kath; Marks-Maran, Di

    2016-01-01

    To prepare the registered nurse of tomorrow in the United Kingdom (UK) to care for patients in general practice (GP)-led services, today's student nurses need to have the opportunity to experience placements with practice nurses to enable them to make positive career choices to become practice nurses in the future. The role of the practice nurse is described in the article. As a pilot project, seventeen students undertook placements with practice nurses in one of seven GP practices selected by the London GP Deanery and the university as having fulfilled the criteria to support student nurses in placements. A mentorship preparation programme was provided to prepare practice nurses for mentoring these students. An evaluation study was undertaken of this pilot project. Findings showed that students were highly positive about the experience; the majority rated this placement as being as good as or better than previous placement experiences. The evaluation also explored the impact on student learning and the value that the placement had. There was a positive impact on students' knowledge and skills in certain clinical areas especially related to health promotion. Students also indicated that they would like to have additional placements with practice nurses and would consider a career as a practice nurse in the future. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Expectations of Cattle Feeding Investors in Feeder Cattle Placements

    OpenAIRE

    Kastens, Terry L.; Schroeder, Ted C.

    1993-01-01

    Cattle feeders appear irrational when they place cattle on feed when projected profits are negative. Long futures positions appear to offer superior returns to cattle feeding investment. Cattle feeder behavior suggests that they believe a downward bias in live cattle futures persists and that cattle feeders use different information than the live cattle futures market price when making placement decisions. This paper examines feeder cattle placement determinants and compares performance of ex...

  7. Guidelines for supporting placement learning via video communications technologies

    OpenAIRE

    Taylor, Teri

    2014-01-01

    Purpose – Current drivers in higher education have led to the questioning of traditional placement support methods. Within many programmes, students undertaking practice-based learning experience structured, one-to-one support from an academic in the placement location. With the financial and environmental implications of this practice, the potential for using video-based communications as a replacement for face-to-face dialogue was explored. The paper aims to discuss the above issues. \\ud \\u...

  8. Mixing advertising and editorial content in radio programmes: appreciation and recall of brand placements versus commercials

    NARCIS (Netherlands)

    van Reijmersdal, E.A.

    2011-01-01

    Although the literature on brand placement is rapidly evolving, no studies thus far have focused on radio brand placement or on the effects of the combination of brand placement and commercials. Therefore, the present experiment (N = 153) focused on the effects of radio brand placement on liking,

  9. The effects of brand placement disclosures on scepticism and brand memory

    NARCIS (Netherlands)

    van Reijmersdal, E.A.; Tutaj, K.; Boerman, S.C.

    2013-01-01

    Recently, the European Union decreed that European countries should use disclosures of brand placement in programs and movies on television to guarantee fair communication. However, an understanding of the effects of disclosing brand placement is lacking. The present study is the first to test the

  10. 34 CFR 300.536 - Change of placement because of disciplinary removals.

    Science.gov (United States)

    2010-07-01

    ... THE EDUCATION OF CHILDREN WITH DISABILITIES Procedural Safeguards Due Process Procedures for Parents and Children Discipline Procedures § 300.536 Change of placement because of disciplinary removals. (a... 34 Education 2 2010-07-01 2010-07-01 false Change of placement because of disciplinary removals...

  11. Product Placement: A Smart Marketing Tool Shifting a Company to the Next Competitive Level

    Directory of Open Access Journals (Sweden)

    Kramolis Jan

    2013-12-01

    Full Text Available The primary aim of this paper was to discover connection between company’s competitiveness and product placement as a marketing tool. The secondary aim was searching for the genesis of product placement. The mentioned issues are explained from the perspectives of three groups: TV studios experts, directors and producers, and other experts (media agencies and advertisers. The Czech Republic market where product placement can be registered is very small – only few television companies. The survey was conducted during years 2011 and 2012 in the Czech Republic. There is no directly measurable tool to tell us exact outputs. However, the results reveal: Marketers are sure that product placement is efficient. The product placement belongs to a longterm marketing field where the brand building is also included. On the basis of the ascertainments acquired by the survey, the basic links between product placement, long-term marketing, and competitiveness are explained in this paper.

  12. Improved Safety and Efficacy of Small-Bore Feeding Tube Confirmation Using an Electromagnetic Placement Device.

    Science.gov (United States)

    Powers, Jan; Luebbehusen, Michael; Aguirre, Lillian; Cluff, Julia; David, Mary Ann; Holly, Vince; Linford, Lorraine; Park, Nancy; Brunelle, Rocco

    2018-04-01

    Early enteral nutrition has been shown to decrease complications and improve patient outcomes. Post pyloric feeding is recommended for patients with gastric intolerance or at high risk for aspiration. Feeding tube placement can be challenging and pose risk of pulmonary complications. Reliance on radiographic confirmation for feeding tube placement exposes the patient to radiation. Electromagnetic placement device (EMPD) may offer a method to minimize pulmonary complications, increase successful placement, and decrease radiation exposure to the patient. The purpose of this study was to evaluate the safety and efficacy of using EMPD verification, instead of routine abdominal radiographic confirmation, for small-bore feeding tube placement. Variables evaluated were adverse events, utilization of radiographs for confirmation, and success rate of feeding tube placement in the ordered location. Two time frames were reviewed. In a 1-year period, 3754 small-bore feeding tubes were placed using EMPD, with zero adverse events noted. Radiographic confirmation was utilized in 0%-29.2% of the EMPD placed tubes. Successful placement of feeding tubes using EMPD ranged from 94%-99.6%. During a 5-year period, 7081 EMPD feeding tubes were evaluated. One adverse event, pneumothorax, occurred during the placement of these 7081 tubes, for a rate of 0.014%. Feeding tube placement confirmation is safe and efficacious via EMPD providing an effective method of feeding tube placement with a success rate >94% into the desired location. EMPD is an accurate verification method of distal tip location, eliminating the need for routine abdominal radiographic confirmation. © 2018 American Society for Parenteral and Enteral Nutrition.

  13. Encountering aged care: a mixed methods investigation of medical students' clinical placement experiences.

    Science.gov (United States)

    Annear, Michael J; Lea, Emma; Lo, Amanda; Tierney, Laura; Robinson, Andrew

    2016-02-04

    Residential aged care is an increasingly important health setting due to population ageing and the increase in age-related conditions, such as dementia. However, medical education has limited engagement with this fast-growing sector and undergraduate training remains primarily focussed on acute presentations in hospital settings. Additionally, concerns have been raised about the adequacy of dementia-related content in undergraduate medical curricula, while research has found mixed attitudes among students towards the care of older people. This study explores how medical students engage with the learning experiences accessible in clinical placements in residential aged care facilities (RACFs), particularly exposure to multiple comorbidity, cognitive impairment, and palliative care. Fifth-year medical students (N = 61) completed five-day clinical placements at two Australian aged care facilities in 2013 and 2014. The placements were supported by an iterative yet structured program and academic teaching staff to ensure appropriate educational experiences and oversight. Mixed methods data were collected before and after the clinical placement. Quantitative data included surveys of dementia knowledge and questions about attitudes to the aged care sector and working with older adults. Qualitative data were collected from focus group discussions concerning medical student expectations, learning opportunities, and challenges to engagement. Pre-placement surveys identified good dementia knowledge, but poor attitudes towards aged care and older adults. Negative placement experiences were associated with a struggle to discern case complexity and a perception of an aged care placement as an opportunity cost associated with reduced hospital training time. Irrespective of negative sentiment, post-placement survey data showed significant improvements in attitudes to working with older people and dementia knowledge. Positive student experiences were explained by in

  14. Modified Miniplates for Temporary Skeletal Anchorage in Orthodontics: Placement and Removal Surgeries

    Science.gov (United States)

    Cornelis, Marie A.; Scheffler, Nicole R.; Mahy, Pierre; Siciliano, Sergio; De Clerck, Hugo J.; Tulloch, J.F. Camilla

    2009-01-01

    Purpose Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons’ perceptions of their use. Patients and Methods We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. Results Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients’ chief complaint was swelling, lasting on average 5.3 ± 2.8 days after placement and 4.5 ± 2.6 days after removal. Conclusions Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment. PMID:18571028

  15. The cost and value of pre-registration clinical placements for Project 2000 students.

    Science.gov (United States)

    Jones, M L; Akehurst, R

    1999-07-01

    The research outlined in this article was commissioned by the Sheffield and North Trent College of Nursing and Midwifery to explore the cost implications of pre-registration clinical placements in the context of Project 2000. The authors outline the methodology and findings of an exercise designed to collect relevant cost information which was not readily available. On the basis of these findings, they suggest that: at 1995/1996 pay and prices, clinical placements cost the education provider approximately pound 890 per student per annum; in terms of real resources, the value to service providers of the service contribution made by second- and third-year nursing and midwifery students on ward-based placements outweighs the value of the time spent by qualified staff on their supervision and education. Once the funding assumptions underlying the introduction of Project 2000 have been taken into account, second- and third-year nursing and midwifery students benefit the service provider by on average pound 3.46 for every hour they spend in an unrostered ward-based placement. The service contribution made by students in community-based clinical placements cannot free staff time in the same way as on the wards and, because qualified staff in these areas are generally more highly graded, the value of the time they spend on the supervision and education of students on placement is higher than in ward-based placements. Second- and third-year students therefore appear to cost the service provider on average pound 0.48 for each hour they spend in a community-based placement. It was not possible to determine whether this cost translates into a reduction in patient contacts.

  16. Nursing students' perceptions of a collaborative clinical placement model: A qualitative descriptive study.

    Science.gov (United States)

    van der Riet, Pamela; Levett-Jones, Tracy; Courtney-Pratt, Helen

    2018-03-01

    Clinical placements are specifically designed to facilitate authentic learning opportunities and are an integral component of undergraduate nursing programs. However, as academics and clinicians frequently point out, clinical placements are fraught with problems that are long-standing and multidimensional in nature. Collaborative placement models, grounded in a tripartite relationship between students, university staff and clinical partners, and designed to foster students' sense of belonging, have recently been implemented to address many of the challenges associated with clinical placements. In this study a qualitative descriptive design was undertaken with the aim of exploring 14 third year third year nursing students' perceptions of a collaborative clinical placement model undertaken in an Australian university. Students participated in audio recorded focus groups following their final clinical placement. Thematic analysis of the interview data resulted in identification of six main themes: Convenience and Camaraderie, Familiarity and Confidence, Welcomed and Wanted, Belongingness and Support, Employment, and The Need for Broader Clinical Experiences. The clinical collaborative model fostered a sense of familiarity for many of the participants and this led to belongingness, acceptance, confidence and meaningful learning experiences. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Experiences of Supervision at Practice Placement Sites

    Directory of Open Access Journals (Sweden)

    Lesley Diack

    2014-01-01

    Full Text Available Background. Whilst placement supervision and clinical education programmes are of significant value in shaping the behaviours of undergraduate healthcare students, appropriate provisions which are efficacious to the learner are somewhat lacking, particularly for students studying on UK MPharm programmes. Objectives. To explore and explain the value of placement supervision to the personal development and employability of undergraduate pharmacy students. Methods. Students participated in a week long community pharmacy pilot programme, a result of a collaborative effort between the School of Pharmacy and Life Sciences and a small consortium of community pharmacies. Students and stakeholders were asked to evaluate their experiences via separate questionnaires which had been developed to elicit views and attitudes. Key Findings. Feedback from students and stakeholders towards the experience was overwhelmingly positive with multiple benefits being reported. Of particular prominence was the emphasis in student feedback on the value of placement supervision to their professional and personal development. Findings were indicative of a development in clinical practice proficiencies, core skills, and improvement in decision-making practice. Conclusions. The benefits of clinical supervision to the professional and personal development of MPharm students are well documented, although attracting professional pharmacy supervisors is proving a problematic task for educational providers in the UK.

  18. Brand Placement in Establishing Corporate Identity - A University Example -

    Directory of Open Access Journals (Sweden)

    Saliha AĞAÇ

    2015-06-01

    Full Text Available With competition becoming ever fiercer, brands must conform to modern marketing and become more influential on consumer perceptions by developing strategies according to the needs and demands of consumers. Hence it is very important to determine how the br and is perceived and placed in the consumer’s mind. Branding is a key issue on the modern agenda. As universities have understood the importance of establishing corporate identity and brand placement, they have joined the race and begun developing social strategies to develop their brand values. These include establishing brand belongingness, advertising and promotions and efforts to make the university stand out among similar ones. Brand placement in the minds of users is attempted through the name, logo , colors, characters and fonts representing the university used on clothing, office material and similar. Brand placement efforts include definitions by consumers of the product or service or attempts to distinguish these from those of competitors. This r esearch deals with a clothing b rand representing a university, brand image and product perceptions as well as the brand placement efforts. The scanning method was used in the research. The brand of casual clothing used as an example for brand placement as well as similarly known brands were examined for their product variety, prices and consumer portfolios. Measurement devices were prepared for the brand placement of the apparel designed and produced for the university, and a pilot trial was performed. I n the pilot trial, a set of questions was asked to a group of randomly chosen 242 people, consisting of academics, university students and administrative staff. The data obta ined were analyzed using SPSS 16 .0. Findings were given in tables according to sta tus variables. The finding of the research indicate that in brand placing efforts, for the intended consumer the apparel’s fabric, stitching and print/embroidery quality, its price

  19. Chemical placement in heterogeneous and long reach horizontal wells

    Energy Technology Data Exchange (ETDEWEB)

    Stalker, Robert; Wahid, Fazrie; Graham, Gordon M.

    2006-03-15

    The effective placement of chemical squeeze treatments in heterogeneous wells and long reach horizontal wells has proved a significant challenge, with various factors including heterogeneity, crossflow and pressure gradients between otherwise non-communicating zones within the well, all contributing to an uneven placement of the scale squeeze treatment into the reservoir. Current methods to circumvent these problems often rely on extremely expensive coiled tubing operations, staged diversion (temporary shut off) treatments or by designing treatments to deliberately overdose some zones in order to gain placement in other (e.g. low permeability) zones. Moreover for deepwater sub sea horizontal wells the costs associated with ''spot'' treating along the length of horizontal wells by coil tubing tractor operations can often be prohibitively expensive. For other very near well bore treatments such as acid stimulation a number of self diverting strategies including gelled acid treatments, staged viscoelastic surfactant treatments and foams have been applied in field treatments with some success. However the properties which make such treatments applicable for acid stimulation may also make them inappropriate for bullhead scale squeeze treatments. Recent work by the current authors has however indicated the possible benefits of using modified injection fluids to aid uniform scale inhibitor placement in such wells in order to effect more even placement. In summary this paper will describe the various options available for achieving self diversion and describes the potential drawbacks associated with the viscous placement fluids commonly used for acid simulation techniques. In addition, various simulation packages commonly used for scale related calculations are reviewed and their limitations, primarily due to the inherent assumptions made and input parameters used, for modelling squeeze treatments using such modified fluids are described. The paper

  20. Minimal guided bone regeneration procedure for immediate implant placement in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Nettemu Sunil Kumar

    2013-01-01

    Full Text Available The anterior maxilla presents a challenging milieu interior for ideal placement of implants because of the compromised bone quality. With the advent of intraoral bone harvesting and augmentation techniques, immediate implant placement into fresh extraction sockets have become more predictable. Immediate implant placement has numerous advantages compared to the delayed procedure including superior esthetic and functional outcomes, maintenance of soft and hard tissue integrity and increased patient compliance. This case report exhibits immediate implant placement in the maxillary esthetic zone by combining a minimal invasive autogenous block bone graft harvest technique for ensuring successful osseointegration of the implant at the extraction site.

  1. Optimal Placement of Phasor Measurement Units with New Considerations

    DEFF Research Database (Denmark)

    Su, Chi; Chen, Zhe

    2010-01-01

    Conventional phasor measurement unit (PMU) placement methods normally use the number of PMU installations as the objective function which is to be minimized. However, the cost of one installation of PMU is not always the same in different locations. It depends on a number of factors. One of these......Conventional phasor measurement unit (PMU) placement methods normally use the number of PMU installations as the objective function which is to be minimized. However, the cost of one installation of PMU is not always the same in different locations. It depends on a number of factors. One...... of these factors is taken into account in the proposed PMU placement method in this paper, which is the number of adjacent branches to the PMU located buses. The concept of full topological observability is adopted and a version of binary particle swarm optimization (PSO) algorithm is utilized. Results from...

  2. Performance and impact of dynamic data placement in ATLAS

    CERN Document Server

    Maier, Thomas; The ATLAS collaboration

    2018-01-01

    For high-throughput computing the efficient use of distributed computing resources relies on an evenly distributed workload, which in turn requires wide availability of input data that is used in physics analysis. In ATLAS, the dynamic data placement agent C3PO was implemented in the ATLAS distributed data management system Rucio which identifies popular data and creates additional, transient replicas to make data more widely and more reliably available. This contribution presents studies on the performance of C3PO and the impact it has on throughput rates of distributed computing in ATLAS. This includes analysis of the placement algorithm selection behaviour regarding the data considered for replication and destination storage elements, usage after the placement decision of the chosen datasets in general and the newly created copies in particular, and the impact on metrics like job waiting times, task completion times and failure rates of tasks.

  3. Student engagement in interprofessional working in practice placement settings.

    Science.gov (United States)

    Pollard, Katherine

    2009-10-01

    . To investigate the nature of student engagement in interprofessional interaction while on placement. Due to continuing emphasis on improving interprofessional collaboration, UK educational establishments are required to offer pre-qualifying health and social care students interprofessional education in order that they acquire relevant competencies. However, few formal interprofessional education initiatives occur in practice settings and little is known about pre-qualifying students' non-formal learning about interprofessional issues while on placement. From 2003-2005 an English Faculty of Health and Social Care conducted a qualitative study to explore opportunities for interprofessional learning and working available to students in practice placement settings. Case studies were conducted in a coronary care ward, a medical ward for older patients, a maternity unit, a paediatric unit, an integrated community learning disabilities team and a residential facility for adults with challenging behaviour. Gaining access was complex, due to variable student timetables and UK research governance requirements. Sites were therefore selected according to geographical area and timing of student placements. Details of interprofessional interaction (formal and informal) were observed and recorded. Interviews were conducted with a convenience sample of 20 practitioners and 15 students. Data were analysed thematically. Student experience varied considerably. Contributing factors included the influence of doctors and differing professional cultures; mentors' support for student engagement in interprofessional working; and individual students' confidence levels. Most sites were managed by nurses and some senior nurses were proactive in involving students interprofessionally. However, many students lacked systematic support for interprofessional engagement. Students lack parity of experience concerning interprofessional activity on placement. Where they do not have systematic

  4. Direct restoration of endodontically treated maxillary central incisors: post or no post at all?

    Science.gov (United States)

    von Stein-Lausnitz, Manja; Bruhnke, M; Rosentritt, M; Sterzenbach, G; Bitter, K; Frankenberger, R; Naumann, M

    2018-04-30

    The aim of this ex-vivo study was to evaluate the impact of cavity size and glass-fiber post (GFP) placement on the load capability of endodontically treated maxillary incisors directly restored with resin composite. Ninety-six extracted human maxillary central incisors were endodontically treated and distributed to four groups (n = 24): access cavity (A), access cavity and uni-proximal class III cavity (U), access cavity and bi-proximal class III cavity (B), and decoronated tooth (D). Specimens were restored with resin composite, and 12 specimen of each group received an adhesively placed glass-fiber post (P). Prior to linear loading, specimens were exposed to thermo-mechanical loading (TCML). Statistical analysis was performed using log-rank test after TCML, Kruskall-Wallis and Mann-Whitney U test to compare load capabilities (F max) . Significantly more failures occurred in group D for specimens without GFP during TCML (p = 0.001). F max (mean (SD) in N was (A) 513 (124), (AP) 554 (201), (U) 438 (171), (UP) 537 (232) (B) 483 (219), (BP) 536 (281), D 143 (181), and DP 500 (331), and differed significantly among groups (p = 0.003). Pair-wise comparison revealed lower F max values for group D compared to all other groups (p central incisors with cavity sizes up to bi-proximal class III may be successfully directly restored with resin composite. Post placement shows no additional effect except for decoronated endodontically treated incisors. Endodontically treated incisors with access cavities to class III cavities can be successfully restored with resin composite. Post placement for decoronated ETT is recommended.

  5. Immediate placement of dental implants in the mandible

    Directory of Open Access Journals (Sweden)

    Gurkar Haraswarupa Puttaraju

    2013-01-01

    Full Text Available This case describes extraction of teeth in the mandibular arch, i.e., 41 42 43 44 45 51 52 53 54 55 56 57 58 (grade two mobility, followed by immediate placement of four dental implants (3i biomet, two in the 45 55 region and two dental implants in 12 21 region. A prefabricated provisional mandibular denture was immediately placed. The purpose of immediate placement was to aid the patient resume his professional duties the next day itself along with esthetic and functional comfort, psychological well-being and most importantly preserving the remaining tissue in a healthy condition.

  6. Perspectives of Foster Parents and Social Workers on Foster Placement Disruption

    Science.gov (United States)

    Taylor, Brian J.; McQuillan, Karen

    2014-01-01

    The potential human and financial costs of foster placement disruption for the children, families, professionals and agencies involved are widely accepted. This service evaluation identified and described perspectives of foster parents and social workers regarding placement disruptions in order to identify the main issues of concern and to derive…

  7. Advanced Placement Academy: Case Study of a Program within a School

    Science.gov (United States)

    Swanson, Julie Dingle; Nagy, Steven

    2014-01-01

    The focus of this study was the first year of implementation of the Advanced Placement Academy (APA), a program within a high school providing honors and Advanced Placement coursework for high-ability African American students with previously limited access to rigorous courses. The qualitative investigation explores practical solutions from…

  8. Catchment features controlling nitrogen dynamics in running waters above the tree line (central Italian Alps

    Directory of Open Access Journals (Sweden)

    R. Balestrini

    2013-03-01

    Full Text Available The study of nitrogen cycling in mountain areas has a long tradition, as it was applied to better understand and describe ecosystem functioning, as well as to quantify long-distance effects of human activities on remote environments. Nonetheless, very few studies, especially in Europe, have considered catchment features controlling nitrogen dynamics above the tree line with focus on running waters. In this study, relationships between some water chemistry descriptors – including nitrogen species and dissolved organic carbon (DOC – and catchment characteristics were evaluated for a range of sites located above the tree line (1950–2650 m a.s.l. at Val Masino, in the central Italian Alps. Land cover categories as well as elevation and slope were assessed at each site. Water samples were collected during the 2007 and 2008 snow free periods, with a nearly monthly frequency. In contrast to dissolved organic nitrogen, nitrate concentrations in running waters showed a spatial pattern strictly connected to the fractional extension of tundra and talus in each basin. Exponential models significantly described the relationships between maximum NO3 and the fraction of vegetated soil cover (negative relation and talus (positive relation, explaining almost 90% of nitrate variation in running waters. Similarly to nitrate but with an opposite behavior, DOC was positively correlated with vegetated soil cover and negatively correlated with talus. Therefore, land cover can be considered one of the most important factors affecting water quality in high-elevation catchments with contrasting effects on N and C pools.

  9. Urethral catheterization facilitates preradiation fiducial marker placement in postprostatectomy patients.

    Science.gov (United States)

    Williams, Christopher; Costa, Joseph; Mandia, Stephen; Henderson, Randal; Marino, Robert; Mendenhall, Nancy

    2012-05-01

    Surgical absence of the prostate can make placement of fiducial markers difficult, because anatomic landmarks are distorted and there is a paucity of substantial tissue to hold fast the markers. We describe a method for improving the accuracy of fiducial marker placement for the purpose of salvage or adjuvant external beam radiation therapy for prostate cancer in patients who have undergone radical prostatectomy. To assist with identification of the urethrovesical junction and to facilitate placement of the markers, a Foley catheter was placed and the balloon was inflated. Gentle traction on the catheter seated the balloon at the bladder neck to echographically define the anatomy of the urethrovesical junction. Next, a rectal ultrasound probe was inserted into the rectum, allowing visualization of the region of the urethrovesical junction. Fiducial markers were then placed bilaterally in the detrusor muscle at the bladder neck or in the periurethral tissue using the applicator needle. The treating radiation oncologist verified that marker placement was suitable for assisting with radiation therapy in all cases. Preradiation pelvic imaging verified that markers were not in the bladder or urethral lumen, and there were no patient complaints of voiding out the markers with urination.

  10. Bipolar hysteroscopic procedures and placement of Essure microinserts for tubal sterilization: a case control study.

    Science.gov (United States)

    Panel, Pierre; Grosdemouge, Isabelle; Houllier, Marie; Renouvel, Frédérique; Friederich, Ludovic; Le Tohic, Arnaud

    2011-06-01

    To assess the effectiveness and complication rate with Essure microinsert placements for tubal sterilization and the concomitant bipolar intrauterine surgical procedure. Case control study. Department of gynecology and obstetrics of a general hospital in France. 382 women, including 41 undergoing one or several concomitant uterine procedures with Essure placement, and 341 undergoing Essure placement only (controls). Essure placement with or without bipolar hysteroscopic procedure for polyp, myoma, or endometrial ablation. Success rate for microinsert placement and complications at 3 months. Forty-one patients had Essure microinserts placed in combination with a bipolar hysteroscopic procedure: endometrial resection (n=32), fibroma resection (n=4), or polyp ablation (n=5). They were compared with 341 patients who underwent Essure placement only. The success rate for Essure placement was 97.6% in the combination group versus 97.6% in the control group. The complication rate was 4.9% (n=2) in the combination group versus 2.6% (n=9) in the control group. The difference in the success and complication rates was not statistically significant. Performing intrauterine bipolar resection during hysteroscopy for sterilization is possible without reducing the Essure placement success rate and without increasing morbidity. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. An X-ray survey of the central molecular zone: Variability of the Fe Kα emission line

    Science.gov (United States)

    Terrier, R.; Clavel, M.; Soldi, S.; Goldwurm, A.; Ponti, G.; Morris, M. R.; Chuard, D.

    2018-05-01

    There is now abundant evidence that the luminosity of the Galactic super-massive black hole (SMBH) has not always been as low as it is nowadays. The observation of varying non-thermal diffuse X-ray emission in molecular complexes in the central 300 pc has been interpreted as delayed reflection of a past illumination by bright outbursts of the SMBH. The observation of different variability timescales of the reflected emission in the Sgr A molecular complex can be well explained if the X-ray emission of at least two distinct and relatively short events (i.e. about 10 yr or less) is currently propagating through the region. The number of such events or the presence of a long-duration illumination are open questions. Variability of the reflected emission all over of the central 300 pc, in particular in the 6.4 keV Fe Kα line, can bring strong constraints. To do so we performed a deep scan of the inner 300 pc with XMM-Newton in 2012. Together with all the archive data taken over the course of the mission, and in particular a similar albeit more shallow scan performed in 2000-2001, this allows for a detailed study of variability of the 6.4 keV line emission in the region, which we present here. We show that the overall 6.4 keV emission does not strongly vary on average, but variations are very pronounced on smaller scales. In particular, most regions showing bright reflection emission in 2000-2001 significantly decrease by 2012. We discuss those regions and present newly illuminated features. The absence of bright steady emission argues against the presence of an echo from an event of multi-centennial duration and most, if not all, of the emission can likely be explained by a limited number of relatively short (i.e. up to 10 yr) events. Images of the Fe Kα emission as FITS files are only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/612/A102

  12. The process and challenges of obtaining and sustaining clinical placements for nursing and allied health students.

    Science.gov (United States)

    Taylor, Christine; Angel, Liz; Nyanga, Lucy; Dickson, Cathy

    2017-10-01

    To describe the process and challenges from a project that aimed to develop processes, source new placements and place students primarily in the discipline of nursing, but also occupational therapy, physiotherapy, podiatry, social work, and speech therapy. Clinical experience in health facilities is an essential element of health professional education, yet globally, there is a lack of clinical placements to meet demands. Educational providers are seeking placements in nontraditional facilities, yet little has been reported on the challenges in the process of procuring clinical placements. The project used a descriptive approach within a quality implementation framework. The project was guided by the quality implementation framework that included four critical steps: considerations of the host setting, structuring the implementation, supporting the implementation and improving future applications. A total of 115 new student placements were finalised across six health disciplines, including elderly care, nongovernment organisations and general practice. Sixty-two nursing students were placed in the new placements during the project. Challenges included communication, the time-consuming nature of the process and 'gatekeeping' blocks to obtaining placements. Recommendations included the importance of personal interaction in developing and maintaining relationships, and the need for clear communication processes and documentation. Potential areas for research are also given. There is great potential for growth in establishing new placements outside the traditional placement facilities for nursing and allied health and for expanding already existing nonhospital placements. Clinical professional experiences are essential to any nursing or allied health programme. There is an increasing demand for, and global lack of, clinical placements for nursing and allied health students. The results provide nursing and allied health educators and managers a framework for planning

  13. Job Placement in Germany: Developments before and after Deregulation. IAB Labour Market Research Topics No. 31.

    Science.gov (United States)

    Walwei, Ulrich

    Since 1994, the German public employment service has not had a monopoly on placement. A new law permits private job placement as an independent activity, but only with a license from the public employment service. Since deregulation, the number of job placement licenses has increased continuously, but the number of placements made by private…

  14. 25 CFR 26.8 - Where do I go to apply for Job Placement and Training assistance?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Where do I go to apply for Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.8 Where do I go to apply for Job Placement and Training assistance? You may apply for Job Placement and Training assistance at the servicing office...

  15. Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Inderpaul Singh Sehgal

    2017-01-01

    Full Text Available Background: Airway obstruction or tracheoesophageal fistula (TEF near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of airway silicone Y-stents. Methods: This was a retrospective analysis of consecutive subjects who underwent placement of silicone Y-stents. The clinical details including the underlying diagnosis, indication for the placement of silicone Y-stents, success of stent placement, and follow-up are presented. The PubMed and EMBASE databases were also reviewed for studies describing the placement of silicone Y-stents. Results: During the study, 27 silicone Y-stents were placed. The mean (standard deviation age of the study population (85.2% males was 57.7 (13.5 years. The stents were placed for airway obstruction in 77.8% and TEF in 29.6% of the patients. The most common underlying disease was carcinoma of the esophagus. The degree of airway obstruction was grade 3–4 in 18 subjects, and respiratory failure was encountered in 18 subjects. The stent was deployed successfully in all the subjects. No deaths were encountered during stent placement. Most subjects had rapid relief of symptoms following the procedure. Excessive secretions and mucostasis were the most common stent-related complications followed by the development of granulation tissue. The systematic review yielded nine studies (338 subjects with airway obstruction and/or TEF. The most common indication for silicone Y-stent placement was tracheobronchial obstruction and TEF due to malignancy. Benign disorders that necessitated stent placement included postintubation tracheal stenosis, airway malacia, and others. The stent was successfully placed in 98% with only one periprocedural death. Granulation tissue formation and mucostasis were the most common stent-related complications. Conclusion

  16. Environmental Assessment for Central Power and Light Company`s proposed Military Highway-CFE tie 138/69-kV transmission line project Brownsville, Cameron County, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    Central Power and Light Company (CPL) intends to upgrade its existing transmission line ties with the Commision Federal de Electricidad (CFE) system in Mexico. CPL currently has a single 69-kilovolt (kV) transmission line in the Brownsville area which connects CPL`s system with the system of CFE. This existing line runs between the Brownsville Switching Station, located on Laredo Road in Brownsville, Cameron County, Texas, and an existing CFE 69-kV line at the Rusteberg Bend of the Rio Grande in Cameron County. Under current conditions of need, the existing 69-kV line does not possess sufficient capability to engage in appropriate power exchanges. Therefore, CPL is proposing to build a new line to link up with CFE. This proposed line would be a double-circuit line, which would (1) continue (on a slightly relocated route) the existing 69-kV tie from CPL`s Brownsville Switching Station to CFE`s facilities, and (2) add a 138-kV tie from the Military Highway Substation, located on Military Highway (US Highway 281), to CFE`s facilities. The proposed 138/69-kV line, which will be constructed and operated by CPL, will be built primarily on steel single-pole structures within an average 60-foot (ft) wide right-of-way (ROW). It will be approximately 6900--9200 ft (1.3--1.7 miles) in length, depending on the alternative route constructed.

  17. Can a clinical placement influence stigma? An analysis of measures of social distance.

    Science.gov (United States)

    Moxham, Lorna; Taylor, Ellie; Patterson, Christopher; Perlman, Dana; Brighton, Renee; Sumskis, Susan; Keough, Emily; Heffernan, Tim

    2016-09-01

    The way people who experience mental illness are perceived by health care professionals, which often includes stigmatising attitudes, can have a significant impact on treatment outcomes and on their quality of life. To determine whether stigma towards people with mental illness varied for undergraduate nursing students who attended a non-traditional clinical placement called Recovery Camp compared to students who attended a 'typical' mental health clinical placement. Quasi-experimental. Seventy-nine third-year nursing students were surveyed; n=40 attended Recovery Camp (intervention), n=39 (comparison group) attended a 'typical' mental health clinical placement. All students completed the Social Distance Scale (SDS) pre- and post-placement and at three-month follow-up. Data analysis consisted of a one-way repeated measures analysis of variance (ANOVA) exploring parameter estimates between group scores across three time points. Two secondary repeated measures ANOVAs were performed to demonstrate the differences in SDS scores for each group across time. Pairwise comparisons demonstrated the differences between time intervals. A statistically significant difference in ratings of stigma between the intervention group and the comparison group existed. Parameter estimates revealed that stigma ratings for the intervention group were significantly reduced post-placement and remained consistently low at three-month follow-up. There was no significant difference in ratings of stigma for the comparison group over time. Students who attended Recovery Camp reported significant decreases in stigma towards people with a mental illness over time, compared to the typical placement group. Findings suggest that a therapeutic recreation based clinical placement was more successful in reducing stigma regarding mental illness in undergraduate nursing students compared to those who attended typical mental health clinical placements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Stabilization, pole placement, and regular implementability

    NARCIS (Netherlands)

    Belur, MN; Trentelman, HL

    In this paper, we study control by interconnection of linear differential systems. We give necessary and sufficient conditions for regular implementability of a-given linear, differential system. We formulate the problems of stabilization and pole placement as problems of finding a suitable,

  19. A virtual reality based simulator for learning nasogastric tube placement.

    Science.gov (United States)

    Choi, Kup-Sze; He, Xuejian; Chiang, Vico Chung-Lim; Deng, Zhaohong

    2015-02-01

    Nasogastric tube (NGT) placement is a common clinical procedure where a plastic tube is inserted into the stomach through the nostril for feeding or drainage. However, the placement is a blind process in which the tube may be mistakenly inserted into other locations, leading to unexpected complications or fatal incidents. The placement techniques are conventionally acquired by practising on unrealistic rubber mannequins or on humans. In this paper, a virtual reality based training simulation system is proposed to facilitate the training of NGT placement. It focuses on the simulation of tube insertion and the rendering of the feedback forces with a haptic device. A hybrid force model is developed to compute the forces analytically or numerically under different conditions, including the situations when the patient is swallowing or when the tube is buckled at the nostril. To ensure real-time interactive simulations, an offline simulation approach is adopted to obtain the relationship between the insertion depth and insertion force using a non-linear finite element method. The offline dataset is then used to generate real-time feedback forces by interpolation. The virtual training process is logged quantitatively with metrics that can be used for assessing objective performance and tracking progress. The system has been evaluated by nursing professionals. They found that the haptic feeling produced by the simulated forces is similar to their experience during real NGT insertion. The proposed system provides a new educational tool to enhance conventional training in NGT placement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Development of the Animal Management and Husbandry Online Placement Tool.

    Science.gov (United States)

    Bates, Lucy; Crowther, Emma; Bell, Catriona; Kinnison, Tierney; Baillie, Sarah

    2013-01-01

    The workplace provides veterinary students with opportunities to develop a range of skills, making workplace learning an important part of veterinary education in many countries. Good preparation for work placements is vital to maximize learning; to this end, our group has developed a series of three computer-aided learning (CAL) packages to support students. The third of this series is the Animal Management and Husbandry Online Placement Tool (AMH OPT). Students need a sound knowledge of animal husbandry and the ability to handle the common domestic species. However, teaching these skills at university is not always practical and requires considerable resources. In the UK, the Royal College of Veterinary Surgeons (RCVS) requires students to complete 12 weeks of pre-clinical animal management and husbandry work placements or extramural studies (EMS). The aims are for students to improve their animal handling skills and awareness of husbandry systems, develop communication skills, and understand their future clients' needs. The AMH OPT is divided into several sections: Preparation, What to Expect, Working with People, Professionalism, Tips, and Frequently Asked Questions. Three stakeholder groups (university EMS coordinators, placement providers, and students) were consulted initially to guide the content and design and later to evaluate previews. Feedback from stakeholders was used in an iterative design process, resulting in a program that aims to facilitate student preparation, optimize the learning opportunities, and improve the experience for both students and placement providers. The CAL is available online and is open-access worldwide to support students during veterinary school.

  1. Esophagojejunostomy Feeding Tube Placement in 5 Dogs with Pancreatitis and Anorexia

    Directory of Open Access Journals (Sweden)

    Forrest Cummings

    2014-01-01

    Full Text Available Enteral feeding tube placement has been described in veterinary medicine for several years. Indications include oral, esophageal, gastrointestinal, pancreatic, hepatic, and neurologic diseases. In this paper, endoscopically assisted placement of an esophagojejunostomy (EJ feeding tube in dogs with pancreatitis and prolonged anorexia is described. To the author’s knowledge there are no published reports of this procedure. Esophagojejunostomy feeding tubes provide an alternative to other forms of postgastric feeding tube placement (e.g., nasojejunal, gastrojejunostomy, and jejunostomy tubes without the associated complications of patient discomfort, sneezing, epistaxis, and peritonitis. Tube occlusion, transient vomiting and loose stool were the most commonly reported complications.

  2. State-PID Feedback for Pole Placement of LTI Systems

    Directory of Open Access Journals (Sweden)

    Sarawut Sujitjorn

    2011-01-01

    Full Text Available Pole placement problems are especially important for disturbance rejection and stabilization of dynamical systems and regarded as algebraic inverse eigenvalue problems. In this paper, we propose gain formulae of state feedback through PID-elements to achieve desired pole placement for a delay-free LTI system with single input. Real and complex stable poles can be assigned with the proposed compact gain formulae. Numerical examples show that our proposed gain formulae can be used effectively resulting in very satisfactory responses.

  3. 25 CFR 26.12 - Who provides the Job Placement and Training?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who provides the Job Placement and Training? 26.12... AND TRAINING PROGRAM General Applicability § 26.12 Who provides the Job Placement and Training? The... associations or small business establishments with apprenticeship or on-the-job training (OJT) programs leading...

  4. The Effect of Subepithelial Connective Tissue Graft Placement on Esthetic Outcomes After Immediate Implant Placement: Systematic Review.

    Science.gov (United States)

    Lee, Chun-Teh; Tao, Chih-Yun; Stoupel, Janet

    2016-02-01

    Immediate implantation, despite many advantages, carries a risk of gingival recession, papilla loss, collapse of ridge contour, and other esthetic complications. Soft tissue graft placement combined with immediate implantation may be used to reduce these concerns. This review aims to systematically analyze clinical esthetic outcomes of the immediate implant combined with soft tissue graft (IMITG). The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines for systematic reviews were used. The electronic search was conducted using MEDLINE (PubMed), EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) from January 1980 to October 2014. Quality assessments of selected articles were performed. Mid-buccal gingival level, interproximal gingival level, facial gingival thickness, gingival ridge dimension, and width of keratinized gingiva were the esthetic outcomes reviewed. Weighted mean difference of mid-buccal gingival level (WDBGL), papilla index score (WDPIS), and width of keratinized gingiva (WDKG) between initial and last measurements were calculated. Other esthetic outcomes were assessed by the descriptive analysis. Ten studies with a minimum of 6-month follow-up were included, and reported esthetic outcomes were analyzed. Mid-buccal gingival level (WDBGL, 0.07 mm; 95% confidence interval [CI] = -0.44 to 0.59; P = 0.12) and interproximal gingival level did not significantly change after IMITG (WDPIS in the mesial site, 0.31; 95% CI = -0.01 to 0.64; P = 0.06; and WDPIS in the distal site, 0.29; 95% CI = -0.06 to 0.65; P = 0.11). Width of keratinized gingiva significantly increased after IMITG (WDKG, 1.27 mm; 95% CI = -0.08 to 2.46; P = 0.04). Facial gingival thickness and gingival ridge dimension could be increased after IMITG. Because of the heterogeneity and limited number of selected studies, no conclusive statement could be made regarding the benefit of IMITG on esthetic outcomes. More randomized controlled trials

  5. Structural damage detection-oriented multi-type sensor placement with multi-objective optimization

    Science.gov (United States)

    Lin, Jian-Fu; Xu, You-Lin; Law, Siu-Seong

    2018-05-01

    A structural damage detection-oriented multi-type sensor placement method with multi-objective optimization is developed in this study. The multi-type response covariance sensitivity-based damage detection method is first introduced. Two objective functions for optimal sensor placement are then introduced in terms of the response covariance sensitivity and the response independence. The multi-objective optimization problem is formed by using the two objective functions, and the non-dominated sorting genetic algorithm (NSGA)-II is adopted to find the solution for the optimal multi-type sensor placement to achieve the best structural damage detection. The proposed method is finally applied to a nine-bay three-dimensional frame structure. Numerical results show that the optimal multi-type sensor placement determined by the proposed method can avoid redundant sensors and provide satisfactory results for structural damage detection. The restriction on the number of each type of sensors in the optimization can reduce the searching space in the optimization to make the proposed method more effective. Moreover, how to select a most optimal sensor placement from the Pareto solutions via the utility function and the knee point method is demonstrated in the case study.

  6. Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults.

    Science.gov (United States)

    Nuttall, Gregory; Burckhardt, Jennifer; Hadley, Anita; Kane, Sarah; Kor, Daryl; Marienau, Mary Shirk; Schroeder, Darrell R; Handlogten, Kathryn; Wilson, Gregory; Oliver, William C

    2016-03-01

    Prior research has provided inconsistent data regarding the risk factors associated with complications from arterial cannulation. The goal of this study was to clearly define the incidence and risks factors associated with arterial cannulation complications. After obtaining institutional review board approval, all patients requiring arterial line placement with documentation were included in this retrospective study between January 1, 2006, and December 31, 2012. Leveraging two robust data warehouses, the Perioperative DataMart and the Mayo Clinic Life Silences System, the authors cross-matched arterial line cannulation with a documented vascular consult, neurologic consult, infection, or return to surgery within 30 days in order to identify the initial patient population. A total of 62,626 arterial lines were placed in 57,787 patients, and 90.1% of the catheters placed were 20-gauge catheters. The radial artery was cannulated in 94.5% of patients. A total of 21 patients were identified as having experienced vascular complications or nerve injuries, resulting in a complication rate of 3.4 per 10,000 (95% CI, 2.1 to 5.1). Cardiac surgery had the largest number of catheters placed (n = 15,419) with 12 complications (complication rate = 7.8 per 10,000; 95% CI, 4.0 to 13.6). The rate of complications differed significantly (P < 0.001) across the three most common catheter sizes (2.7 per 10,000 [95% CI, 1.5 to 4.4] for 20 gauge, 17.2 per 10,000 [95% CI, 4.7 to 43.9] for 18 gauge, and 9.4 per 10,000 [95% CI, 1.1 to 34.1] for 5 French). In a large retrospective study, the authors document a very low rate of complications with arterial line placement.

  7. Strengthening rural health placements for medical students ...

    African Journals Online (AJOL)

    Strengthening rural health placements for medical students: Lessons for South Africa ... rural health, primary healthcare and National Health Insurance strategies. ... preferential selection of students with a rural background, positioning rural ...

  8. Heuristic Data Placement for Data-Intensive Applications in Heterogeneous Cloud

    Directory of Open Access Journals (Sweden)

    Qing Zhao

    2016-01-01

    Full Text Available Data placement is an important issue which aims at reducing the cost of internode data transfers in cloud especially for data-intensive applications, in order to improve the performance of the entire cloud system. This paper proposes an improved data placement algorithm for heterogeneous cloud environments. In the initialization phase, a data clustering algorithm based on data dependency clustering and recursive partitioning has been presented, and both the factor of data size and fixed position are incorporated. And then a heuristic tree-to-tree data placement strategy is advanced in order to make frequent data movements occur on high-bandwidth channels. Simulation results show that, compared with two classical strategies, this strategy can effectively reduce the amount of data transmission and its time consumption during execution.

  9. Single perineal incision placement of artificial urinary sphincter with cadaveric correlation of sub-dartos pump placement

    Directory of Open Access Journals (Sweden)

    Cooper R. Benson

    Full Text Available ABSTRACT Purpose We present a novel AUS implantation technique using a single perineal incision for single device placement or in combination with an inflatable penile prosthesis (IPP. Urinary and sexual dysfunction following the management of prostate cancer has a significant impact on the quality of life of our patients. While there are marginal changes in the prosthetic devices, we strive to reduce post-operative morbidity while maximizing efficacy. Materials and Methods We retrospectively reviewed the outcomes of 6 patients who underwent single perineal incision placement of a virgin AUS in 2014, 3 with simultaneous IPP placement. In all cases, the pressure regulating balloons (PRB were placed in a high sub-muscular ectopic position and the pumps were placed into a sub-dartos pouch through the perineal incision, which was also validated using a cadaveric model. Results The mean patient age was 61 (SD, 7.5 years with mean body mass index of 31 (SD, 5.9. The average pre-operative pad usage was 7.7 (SD 1.63 pads per day. The mean follow-up was 13.9 months (SD 9.45. Four out of the six patients reported utilizing ≤1 pad daily at follow-up. The one patient who was not initially dry required downsizing of his cuff to 3.5cm; the remaining patient was lost to follow-up. There were no identifiable perioperative or post-operative complications. Conclusions We present our initial report of using a single perineal incision for AUS implantation with a validated sub-dartos pump location, which is safe and effective for implantation of an AUS as a single or double implantation in well-selected patients.

  10. 33 CFR 74.01-15 - Charges for placement of temporary aids.

    Science.gov (United States)

    2010-07-01

    ... temporary aids. 74.01-15 Section 74.01-15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION CHARGES FOR COAST GUARD AIDS TO NAVIGATION WORK Charges to the Public § 74.01-15 Charges for placement of temporary aids. Charges for placement of temporary aids will be...

  11. 34 CFR 300.327 - Educational placements.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Educational placements. 300.327 Section 300.327 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION ASSISTANCE TO STATES FOR THE EDUCATION OF...

  12. An efficient macro-cell placement algorithm

    NARCIS (Netherlands)

    Aarts, E.H.L.; Bont, de F.M.J.; Korst, J.H.M.; Rongen, J.M.J.

    1991-01-01

    A new approximation algorithm is presented for the efficient handling of large macro-cell placement problems. The algorithm combines simulated annealing with new features based on a hierarchical approach and a divide-and-conquer technique. Numerical results show that these features can lead to a

  13. Molecular gas in the central parsec of the Galaxy

    Science.gov (United States)

    Ciurlo, Anna

    2015-08-01

    In the central parsec of the Galaxy the environment of the black hole presents two different gas structures: the neutral Circumnuclear Disc (CND) and the ionized Minispiral. In order to study the transition between the two structures we have investigated the presence of neutral gas in the inner part of the CND, where the ionized Minispiral lies. Such study is carried out through spectro-imaging data of the central cavity observed with VLT/SPIFFI. Such data cover several H2 lines and the Brγ line. In order to preserve the spatial resolution and avoid edge effects we applied a new line fitting method, which consists on a regularized three- dimensional fit. Thank to the new method we present the highest resolution maps of the H2 emission in the Central parsec, together with velocity and width maps. The analysis of the H2 1-0 S(1) line leads to the detection of three components of the emission: one in the background of the Minispiral, one in the CND, and one in the Minispiral northern arm. This finding is confirmed by others ortho lines 1-0 S(3) and Q(3). Some para lines are detectable, but no complete map can be achieved. However some portion of the field have been studied for all detectable lines and in particular a strong emission at the entrance of the Minicavity is detected. Lines fluxes allow to trace excitation diagrams which lead to excitation temperature of 1200 K in the CND and T>1500 K in the central cavity. The clear higher temperature of the gas in the central cavity is related to the higher density of UV photons and cosmic rays and this means that H2 molecules have thus a shorter mean life during which thermalization cannot fully occur, it is possible for molecular hydrogen to be formed in a state where peculiar state are favoured. The hypothesis is that we are observing not all the H2 but just the one which is situated at the border of the clouds, a mince shell of gas, heated by the UV central field, which gives a new and interesting picture not only of

  14. MICROARRAY IMAGE GRIDDING USING GRID LINE REFINEMENT TECHNIQUE

    Directory of Open Access Journals (Sweden)

    V.G. Biju

    2015-05-01

    Full Text Available An important stage in microarray image analysis is gridding. Microarray image gridding is done to locate sub arrays in a microarray image and find co-ordinates of spots within each sub array. For accurate identification of spots, most of the proposed gridding methods require human intervention. In this paper a fully automatic gridding method which enhances spot intensity in the preprocessing step as per a histogram based threshold method is used. The gridding step finds co-ordinates of spots from horizontal and vertical profile of the image. To correct errors due to the grid line placement, a grid line refinement technique is proposed. The algorithm is applied on different image databases and results are compared based on spot detection accuracy and time. An average spot detection accuracy of 95.06% depicts the proposed method’s flexibility and accuracy in finding the spot co-ordinates for different database images.

  15. ALMA MULTI-LINE IMAGING OF THE NEARBY STARBURST NGC 253

    Energy Technology Data Exchange (ETDEWEB)

    Meier, David S. [New Mexico Institute of Mining and Technology, 801 Leroy Place, Socorro, NM 87801 (United States); Walter, Fabian; Zschaechner, Laura K. [Max-Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Bolatto, Alberto D.; Veilleux, Sylvain; Warren, Steven R. [Department of Astronomy and Joint Space-Science Institute, University of Maryland, College Park, MD 20742 (United States); Leroy, Adam K. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Ott, Jürgen [National Radio Astronomy Observatory, Pete V. Domenici Array Science Center, P.O. Box O, Socorro, NM 87801 (United States); Rosolowsky, Erik [Department of Physics, University of Alberta, Edmonton, AB T6G 2E1 (Canada); Weiß, Axel [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany); Zwaan, Martin A., E-mail: dmeier@nmt.edu [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching bei München (Germany)

    2015-03-01

    We present spatially resolved (∼50 pc) imaging of molecular gas species in the central kiloparsec of the nearby starburst galaxy NGC 253, based on observations taken with the Atacama Large Millimeter/submillimeter Array. A total of 50 molecular lines are detected over a 13 GHz bandwidth imaged in the 3 mm band. Unambiguous identifications are assigned for 27 lines. Based on the measured high CO/C{sup 17}O isotopic line ratio (≳350), we show that {sup 12}CO(1-0) has moderate optical depths. A comparison of the HCN and HCO{sup +} with their {sup 13}C-substituted isotopologues shows that the HCN(1-0) and HCO{sup +}(1-0) lines have optical depths at least comparable to CO(1-0). H{sup 13}CN/H{sup 13}CO{sup +} (and H{sup 13}CN/HN{sup 13}C) line ratios provide tighter constraints on dense gas properties in this starburst. SiO has elevated abundances across the nucleus. HNCO has the most distinctive morphology of all the bright lines, with its global luminosity dominated by the outer parts of the central region. The dramatic variation seen in the HNCO/SiO line ratio suggests that some of the chemical signatures of shocked gas are being erased in the presence of dominating central radiation fields (traced by C{sub 2}H and CN). High density molecular gas tracers (including HCN, HCO{sup +}, and CN) are detected at the base of the molecular outflow. We also detect hydrogen β recombination lines that, like their α counterparts, show compact, centrally peaked morphologies, distinct from the molecular gas tracers. A number of sulfur based species are mapped (CS, SO, NS, C{sub 2}S, H{sub 2}CS, and CH{sub 3}SH) and have morphologies similar to SiO.

  16. Pregnancy after Essure placement: report of two cases.

    Science.gov (United States)

    Moses, A Whitney; Burgis, Judith T; Bacon, Janice L; Risinger, Jennifer

    2008-03-01

    To report two cases of pregnancy after placement of Essure micro-inserts. Case report. University-based Department of Obstetrics and Gynecology. Patient 1, a 38-year-old woman, presented with a positive pregnancy test 7 months after Essure hysteroscopic sterilization. Patient 2, a 35-year-old female, became pregnant approximately 1 year after undergoing the Essure procedure. Patient 1 received obstetric ultrasounds, a prophylactic cerclage, a cesarean section, and a tubal ligation. Patient 2 underwent a postprocedure hysterosalpingogram, an obstetric ultrasound, pregnancy termination, diagnostic pelvic ultrasound, and a hysterectomy. Documentation of normal progress of pregnancy after Essure placement. Patient 1 carried an uncomplicated pregnancy to term with an Essure micro-insert in place. Patient 2 became pregnant despite an hysterosalpingogram showing tubal occlusion and was ultimately found to have a micro-insert perforating the uterine wall. The presence of Essure micro-inserts in the fallopian tubes do not appear to interfere with implantation and pregnancy. Uterine perforation by an Essure micro-insert in proximity to the tubal ostia may mimic proper micro-insert placement and bilateral tubal occlusion on both hysterosalpingogram and saline infusion sonography.

  17. Endotracheal tube placement by EMT-Basics in a rural EMS system.

    Science.gov (United States)

    Pratt, Jeffrey C; Hirshberg, Alan J

    2005-01-01

    To evaluate the effectiveness of an intubation-training module and special-waiver project in which Emergency Medical Technician (EMT)-Basics were trained to perform endotracheal intubations in a rural community. This was a prospective observational study over a four-year period (July 1998 through May 2002) of all intubation attempts by EMT-Basics in the field. The authors observed intubation data, training methods, and quality-assurance methods of a special-waiver project agreed to by the State Department of Public Health to train and allow EMT-Basics to intubate patients. Data were from documentation unique to the project. Project documentation evaluated the placement and complication(s) of endotracheal tube (ETT) placement after arrival to the emergency department. An intubation attempt was defined as direct laryngoscopy. A successful attempt was defined as an appropriately sized ETT placed and secured in the trachea below the vocal cords and above the carina. Confirmation of placement in the field included accepted clinical methods and the use of qualitative colorimetric end-tidal carbon dioxide detectors. The EMT-Basics were trained using a paramedic curriculum, including operating room intubations on live adult patients. All patients were in either cardiopulmonary or respiratory arrest. Thirty-two intubations were performed by EMT-Basics. Thirty attempts were successful and two were unsuccessful (94%; 95% confidence interval [CI] 80-98%). Unsuccessful ETT placements were managed with accepted basic life support airway standards. There were no unrecognized esophageal ETT placements (0%; 95% CI 0-11%). This study demonstrated that with an intensive training program using selected highly motivated providers and close monitoring, a program of EMT-Basic ETT placement in a rural setting can achieve acceptable success rates in patients in cardiac or respiratory arrest.

  18. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Han, Xinwei, E-mail: hanxinwei2006@163.com; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua [The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)

    2016-08-15

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 ± 3.457 and 8.993 ± 0.961 mm; 1 month post-removal; 16.353 ± 4.132 and 8.357 ± 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 ± 2.351 and 2.143 ± 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  19. Embracing Errors in Simulation-Based Training: The Effect of Error Training on Retention and Transfer of Central Venous Catheter Skills.

    Science.gov (United States)

    Gardner, Aimee K; Abdelfattah, Kareem; Wiersch, John; Ahmed, Rami A; Willis, Ross E

    2015-01-01

    Error management training is an approach that encourages exposure to errors during initial skill acquisition so that learners can be equipped with important error identification, management, and metacognitive skills. The purpose of this study was to determine how an error-focused training program affected performance, retention, and transfer of central venous catheter (CVC) placement skills when compared with traditional training methodologies. Surgical interns (N = 30) participated in a 1-hour session featuring an instructional video and practice performing internal jugular (IJ) and subclavian (SC) CVC placement with guided instruction. All interns underwent baseline knowledge and skill assessment for IJ and SC (pretest) CVC placement; watched a "correct-only" (CO) or "correct + error" (CE) instructional video; practiced for 30 minutes; and were posttested on knowledge and IJ and SC CVC placement. Skill retention and transfer (femoral CVC placement) were assessed 30 days later. All skills tests (pretest, posttest, and transfer) were videorecorded and deidentified for evaluation by a single blinded instructor using a validated 17-item checklist. Both the groups exhibited significant improvements (p error-based activities and discussions into training programs can be beneficial for skill retention and transfer. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  1. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  2. Catheter placement via the occipital artery to achieve superselective intra-arterial chemotherapy for oral cancer

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2008-01-01

    Superselective intra-arterial chemotherapy via the superficial temporal artery (STA) has become useful for oral cancer. However, this method can not be performed if catheter placement via the STA is impossible. Therefore, we report a surgical method for catheter placement via the occipital artery (OA) to achieve retrograde superselective intra-arterial chemotherapy. Preoperatively, three-dimensional computed tomography angiography was performed to identify the course of the external carotid artery and the relationship between OA and the target artery. Ten patients with oral cancer underwent catheter placement via the OA with Doppler ultrasound and Harmonic Scalpel under local anesthesia. Catheter placement via the OA was superselectively successful in all the patients. The mean exposure time of OA and mean operating time were 17.5 min and 70.5 min, respectively. Catheter placement via the OA is useful when catheter placement via the STA is impossible. Three-dimensional vascular mapping and the use of Doppler ultrasound and Harmonic Scalpel can shorten the surgical time. (author)

  3. BCDP: Budget Constrained and Delay-Bounded Placement for Hybrid Roadside Units in Vehicular Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    Peng Li

    2014-11-01

    Full Text Available In vehicular ad hoc networks, roadside units (RSUs placement has been proposed to improve the the overall network performance in many ITS applications. This paper addresses the budget constrained and delay-bounded placement problem (BCDP for roadside units in vehicular ad hoc networks. There are two types of RSUs: cable connected RSU (c-RSU and wireless RSU (w-RSU. c-RSUs are interconnected through wired lines, and they form the backbone of VANETs, while w-RSUs connect to other RSUs through wireless communication and serve as an economical extension of the coverage of c-RSUs. The delay-bounded coverage range and deployment cost of these two cases are totally different. We are given a budget constraint and a delay bound, the problem is how to find the optimal candidate sites with the maximal delay-bounded coverage to place RSUs such that a message from any c-RSU in the region can be disseminated to the more vehicles within the given budget constraint and delay bound. We first prove that the BCDP problem is NP-hard. Then we propose several algorithms to solve the BCDP problem. Simulation results show the heuristic algorithms can significantly improve the coverage range and reduce the total deployment cost, compared with other heuristic methods.

  4. Causative Organisms and Associated Antimicrobial Resistance in Healthcare-Associated, Central Line-Associated Bloodstream Infections From Oncology Settings, 2009-2012.

    Science.gov (United States)

    See, Isaac; Freifeld, Alison G; Magill, Shelley S

    2016-05-15

    Recent antimicrobial resistance data are lacking from inpatient oncology settings to guide infection prophylaxis and treatment recommendations. We describe central line-associated bloodstream infection (CLABSI) pathogens and antimicrobial resistance patterns reported from oncology locations to the Centers for Disease Control and Prevention's National Healthcare Safety Network (NHSN). CLABSI data reported to NHSN from 2009 to 2012 from adult inpatient oncology locations were compared to data from nononcology adult locations within the same hospitals. Pathogen profile, antimicrobial resistance rates, and CLABSI incidence rates per 1000 central line-days were calculated. CLABSI incidence rates were compared using Poisson regression. During 2009-2012, 4654 CLABSIs were reported to NHSN from 299 adult oncology units. The most common organisms causing CLABSI in oncology locations were coagulase-negative staphylococci (16.9%), Escherichia coli (11.8%), and Enterococcus faecium (11.4%). Fluoroquinolone resistance was more common among E. coli CLABSI in oncology than nononcology locations (56.5% vs 41.5% of isolates tested; P oncology compared to nononcology locations for fluoroquinolone-resistant E. coli (rate ratio, 7.37; 95% confidence interval [CI], 6.20-8.76) and vancomycin-resistant E. faecium (rate ratio, 2.27, 95% CI, 2.03-2.53). However, resistance rates for some organisms, such as Klebsiella species and Pseudomonas aeruginosa, were lower in oncology than in nononcology locations. Antimicrobial-resistant E. coli and E. faecium have become significant pathogens in oncology. Practices for antimicrobial prophylaxis and empiric antimicrobial therapy should be regularly assessed in conjunction with contemporary antimicrobial resistance data. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  5. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  6. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  7. Perceived Impacts of a Public Health Training Center Field Placement Program Among Trainees

    Directory of Open Access Journals (Sweden)

    Patrik eJohansson

    2014-07-01

    Full Text Available There is heightened interest in identifying the impact of the federally-funded Public Health Training Center (PHTC program. Although evaluation studies have been conducted of public health training in general, evaluations of PHTC programs are rare. Field placement components are Congressionally-mandated requirements of PHTCs. Field placements are typically intensive, supervised externships for students to gain public health experience with local health departments or non-profit organizations. We have found no published evaluations of PHTC field placement components. This may be because of their small size and unique nature. We designed and evaluated a 200-hour field placement program at an established Public Health Training Center. The evaluation included pre/post surveys measuring public health core competencies, and post-experience interviews. We found significant increases in three competency domains among trainees: policy development and program planning, communication skills, and community dimensions of practice. These outcomes contribute to an evidence base on the efficacy of PHTC field placement programs, and underscore their role in public health training.

  8. Common ECG Lead Placement Errors. Part I: Limb Lead Reversals

    Directory of Open Access Journals (Sweden)

    Allison V. Rosen

    2015-10-01

    Full Text Available Background: Electrocardiography (ECG is a very useful diagnostic tool. However, errors in placement of ECG leads can create artifacts, mimic pathologies, and hinder proper ECG interpretation. It is important for members of the health care team to be able to recognize the common patterns resulting from lead placement errors. Methods: 12-lead ECGs were recorded in a single male healthy subject in his mid 20s. Six different limb lead reversals were compared to ECG recordings from correct lead placement. Results: Classic ECG patterns were observed when leads were reversed. Methods of discriminating these ECG patterns from true pathologic findings were described. Conclusion: Correct recording and interpretation of ECGs is key to providing optimal patient care. It is therefore crucial to be able to recognize common ECG patterns that are indicative of lead reversals.

  9. Validation of Foot Placement Locations from Ankle Data of a Kinect v2 Sensor.

    Science.gov (United States)

    Geerse, Daphne; Coolen, Bert; Kolijn, Detmar; Roerdink, Melvyn

    2017-10-10

    The Kinect v2 sensor may be a cheap and easy to use sensor to quantify gait in clinical settings, especially when applied in set-ups integrating multiple Kinect sensors to increase the measurement volume. Reliable estimates of foot placement locations are required to quantify spatial gait parameters. This study aimed to systematically evaluate the effects of distance from the sensor, side and step length on estimates of foot placement locations based on Kinect's ankle body points. Subjects (n = 12) performed stepping trials at imposed foot placement locations distanced 2 m or 3 m from the Kinect sensor (distance), for left and right foot placement locations (side), and for five imposed step lengths. Body points' time series of the lower extremities were recorded with a Kinect v2 sensor, placed frontoparallelly on the left side, and a gold-standard motion-registration system. Foot placement locations, step lengths, and stepping accuracies were compared between systems using repeated-measures ANOVAs, agreement statistics and two one-sided t -tests to test equivalence. For the right side at the 2 m distance from the sensor we found significant between-systems differences in foot placement locations and step lengths, and evidence for nonequivalence. This distance by side effect was likely caused by differences in body orientation relative to the Kinect sensor. It can be reduced by using Kinect's higher-dimensional depth data to estimate foot placement locations directly from the foot's point cloud and/or by using smaller inter-sensor distances in the case of a multi-Kinect v2 set-up to estimate foot placement locations at greater distances from the sensor.

  10. A Meta-Analysis of Bilateral Essure® Procedural Placement Success Rates on First Attempt.

    Science.gov (United States)

    Frietze, Gabriel; Leyser-Whalen, Ophra; Rahman, Mahbubur; Rouhani, Mahta; Berenson, Abbey B

    2015-12-01

    Background: The Essure ® (Bayer HealthCare Pharmaceuticals, Leverkusen, Germany) female sterilization procedure entails using a hysteroscope to guide a microinsert into the Fallopian tube openings. Failed placement can lead to patient dissatisfaction, repeat procedures, unintended or ectopic pregnancy, perforation of internal organs, or need for subsequent medical interventions. Additional interventions increase women's health risks, and costs for patients and the health care industry. Demonstrated successful placement rates are 63%-100%. To date, there have not been any systematic analyses of variables associated with placement rates. Objectives: The aims of this review were: (1) to estimate the average rate of successful bilateral Essure microinsert placement on first attempt; and (2) to identify variables associated with successful placement. Materials and Methods: A meta-analysis was conducted on 64 published studies and 19 variables. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, all published studies between November 2001 and February 2015 were reviewed. The studies were taken from from PubMed and Google Scholar, and by using the the "snowball" method that reported variables associated with successful bilateral Essure placement rates. Results: The weighted average rate of successful bilateral microinsert placement on first attempt was 92% (0.92 [95% confidence interval: 0.904-0.931]). Variables associated with successful placements were: (1) newer device models; (2) higher body mass index; and (3) a higher percent of patients who received local anesthesia. Conclusions: The data gathered for this review indicate that the highest bilateral success rates may be obtained by utilizing the newest Essure device model with local anesthesia in heavier patients. More standardized data reporting in published Essure studies is recommended. (J GYNECOL SURG 31:308).

  11. Nursing students' perceptions of their clinical learning environment in placements outside traditional hospital settings.

    Science.gov (United States)

    Bjørk, Ida T; Berntsen, Karin; Brynildsen, Grethe; Hestetun, Margrete

    2014-10-01

    To explore students' opinions of the learning environment during clinical placement in settings outside traditional hospital settings. Clinical placement experiences may influence positively on nursing students attitudes towards the clinical setting in question. Most studies exploring the quality of clinical placements have targeted students' experience in hospital settings. The number of studies exploring students' experiences of the learning environment in healthcare settings outside of the hospital venue does not match the growing importance of such settings in the delivery of health care, nor the growing number of nurses needed in these venues. A survey design was used. The Clinical Learning Environment Inventory was administered to two cohorts of undergraduate nursing students (n = 184) after clinical placement in mental health care, home care and nursing home care. Nursing students' overall contentment with the learning environment was quite similar across all three placement areas. Students in mental health care had significantly higher scores on the subscale individualisation, and older students had significantly higher scores on the total scale. Compared with other studies where the Clinical Learning Environment Inventory has been used, the students' total scores in this study are similar or higher than scores in studies including students from hospital settings. Results from this study negate the negative views on clinical placements outside the hospital setting, especially those related to placements in nursing homes and mental healthcare settings. Students' experience of the learning environment during placements in mental health care, home care and nursing homes indicates the relevance of clinical education in settings outside the hospital setting. © 2014 The Authors. Journal of Clinical Nursing published by John Wiley & Sons Ltd.

  12. Foot placement strategy in pushing and pulling.

    Science.gov (United States)

    Lee, Tzu-Hsien

    2018-01-01

    Pushing and pulling tasks are very common in daily and industrial workplaces. They are one major source of musculoskeletal complaints. This study aimed to examine the foot placement strategy while pushing and pulling. Thirteen young males and ten young females were recruited as participants. A two (pushing and pulling) by four (48 cm, 84 cm, 120 cm, and 156 cm) factorial design was used. Exertion direction and exertion height significantly affected foot placement strategy. Pushing task needed more anteroposterior space than pulling task. The percentages of female/male for trailing foot position ranged from 77% to 90% (pushing) and from 80% to 93% (pulling) across the exertion heights. Practitioners should provide an anteroposterior space approximately to 70% body stature for workers to exert their maximum pulling and pushing strengths.

  13. 25 CFR 26.15 - What makes an applicant eligible for Job Placement and Training services?

    Science.gov (United States)

    2010-04-01

    ... SERVICES JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.15 What makes an applicant eligible for Job Placement and Training services? You are eligible for services if: (a) You meet the definition... show a need for job training or placement services in order to become gainfully and meaningfully...

  14. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  15. Parallel algorithms for placement and routing in VLSI design. Ph.D. Thesis

    Science.gov (United States)

    Brouwer, Randall Jay

    1991-01-01

    The computational requirements for high quality synthesis, analysis, and verification of very large scale integration (VLSI) designs have rapidly increased with the fast growing complexity of these designs. Research in the past has focused on the development of heuristic algorithms, special purpose hardware accelerators, or parallel algorithms for the numerous design tasks to decrease the time required for solution. Two new parallel algorithms are proposed for two VLSI synthesis tasks, standard cell placement and global routing. The first algorithm, a parallel algorithm for global routing, uses hierarchical techniques to decompose the routing problem into independent routing subproblems that are solved in parallel. Results are then presented which compare the routing quality to the results of other published global routers and which evaluate the speedups attained. The second algorithm, a parallel algorithm for cell placement and global routing, hierarchically integrates a quadrisection placement algorithm, a bisection placement algorithm, and the previous global routing algorithm. Unique partitioning techniques are used to decompose the various stages of the algorithm into independent tasks which can be evaluated in parallel. Finally, results are presented which evaluate the various algorithm alternatives and compare the algorithm performance to other placement programs. Measurements are presented on the parallel speedups available.

  16. Optimized Virtual Machine Placement with Traffic-Aware Balancing in Data Center Networks

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2016-01-01

    Full Text Available Virtualization has been an efficient method to fully utilize computing resources such as servers. The way of placing virtual machines (VMs among a large pool of servers greatly affects the performance of data center networks (DCNs. As network resources have become a main bottleneck of the performance of DCNs, we concentrate on VM placement with Traffic-Aware Balancing to evenly utilize the links in DCNs. In this paper, we first proposed a Virtual Machine Placement Problem with Traffic-Aware Balancing (VMPPTB and then proved it to be NP-hard and designed a Longest Processing Time Based Placement algorithm (LPTBP algorithm to solve it. To take advantage of the communication locality, we proposed Locality-Aware Virtual Machine Placement Problem with Traffic-Aware Balancing (LVMPPTB, which is a multiobjective optimization problem of simultaneously minimizing the maximum number of VM partitions of requests and minimizing the maximum bandwidth occupancy on uplinks of Top of Rack (ToR switches. We also proved it to be NP-hard and designed a heuristic algorithm (Least-Load First Based Placement algorithm, LLBP algorithm to solve it. Through extensive simulations, the proposed heuristic algorithm is proven to significantly balance the bandwidth occupancy on uplinks of ToR switches, while keeping the number of VM partitions of each request small enough.

  17. Feedback and assessment for clinical placements: achieving the right balance

    Directory of Open Access Journals (Sweden)

    Burgess A

    2015-05-01

    Full Text Available Annette Burgess, Craig Mellis Central Clinical School, Sydney Medical School, The University of Sydney, Sydney, NSW, Australia Abstract: During clinical placements, the provision of feedback forms an integral part of the learning process and enriches students' learning experiences. The purpose of feedback is to improve the learner's knowledge, skills, or behavior. Receipt of accurate feedback can help to narrow the gap between actual and desired performance. Effective and regular feedback has the potential to reinforce good practice and motivate the learner toward the desired outcome. Despite the obvious role of feedback in effective teaching and learning, a common complaint from students is that they do not receive adequate feedback. Unfortunately, skills in giving and receiving feedback are rarely taught to students or clinicians. This study aims to provide an understanding of the role of feedback within the learning process, consider consequences of inadequate or poorly given feedback, consider the barriers to the feedback process, provide practical guidelines for providing feedback, and consider the need for student and faculty development in feedback skills. Keywords: medical students, formative, summative, assessment

  18. Outcome of ureteral stent placement for treatment of benign ureteral obstruction in dogs: 44 cases (2010-2013).

    Science.gov (United States)

    Pavia, Philippa R; Berent, Allyson C; Weisse, Chick W; Neiman, Dana; Lamb, Kenneth; Bagley, Demetrius

    2018-03-15

    OBJECTIVE To describe the technique and short- and long-term outcomes for dogs undergoing double-pigtail ureteral stent placement for treatment of benign ureteral obstruction. DESIGN Retrospective case series. ANIMALS 44 dogs (57 ureters). PROCEDURES Medical records of dogs that underwent ureteral stenting for treatment of benign ureteral obstruction between 2010 and 2013 were reviewed. Signal-ment, history, pertinent diagnostic imaging results, endourologic and post-procedural details, duration of hospitalization, complications, and outcome (short term, 7 to 30 days; long term, > 30 days) were recorded. Ureteral stent placement was performed endoscopically, surgically, or both, with fluoroscopic guidance. RESULTS 57 ureters (44 dogs) underwent stenting because of obstructive ureterolithiasis (n = 48 [84%]), stricture (5 [9%]), or both (4 [7%]). Endoscopic or surgical techniques were successful for stent placement in 45 of 55 and 12 of 12 ureters (34/42 and 10/10 dogs), respectively. Median hospitalization time was 1 day. Median creatinine concentration was 2 mg/dL prior to stenting and 1.3 mg/dL 3 months after the procedure. Urinary tract infections were present in 26 of 44 (59%) dogs prior to stenting and in 11 of 43 dogs (26%) after stenting. One of the 44 (2%) dogs died after undergoing stenting, but the cause of death was not related to the procedure. Median follow-up time was 1,158 days (range, 3 to > 1,555 days), with 30 of 44 dogs alive at the time of last follow-up. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ureteral stenting may be a viable option for first-line treatment of dogs with benign ureteral obstruction. However, patients should be monitored for urinary tract infection following stenting.

  19. BIBLIOGRAPHIC GUIDE FOR ADVANCED PLACEMENT, LATIN.

    Science.gov (United States)

    BARRON, ROBERT; ROSELLE, LEONE

    LITERARY AND CRITICAL WORKS, REFERENCE BOOKS, PERIODICALS, RECORDS, FILMS, AND FILMSTRIPS DEALING WITH ROMAN LITERATURE, HISTORY, CIVILIZATION, MYTHOLOGY, AND LANGUAGE ARE INCLUDED IN THIS BIBLIOGRAPHY OF RECOMMENDED READING IN ENGLISH FOR ADVANCED PLACEMENT PROGRAMS IN LATIN. THE LIST IS DIVIDED INTO TWO $500 GROUPS, SO THAT FOR CONVENIENCE IN…

  20. Practitioner perspectives on extended clinical placement programs in optometry.

    Science.gov (United States)

    Bentley, Sharon A; Cartledge, Amy; Guest, Daryl J; Cappuccio, Skye; Woods, Craig A

    2016-05-01

    Some universities are looking to provide a more diverse range of clinical learning experiences through extended clinical placement programs. This approach will potentially have a significant impact on practitioners. The aim of this study was to conduct a national survey of optometrists to ascertain their perspectives on participating in extended clinical placement programs. Members of Optometry Australia were invited to participate in a survey conducted during June and July 2014. A total of 268 practitioners participated (six per cent of registered Australian optometrists): 159 were predominantly employees or locums and 109 were owners or managers who identified as the key representative of a practice or organisation for the purpose of this survey. Almost two-thirds (65 per cent) of participants, who were employees or locums were supportive of extended clinical placement programs. Among this group, females were more likely to be supportive than males (p = 0.033). In comparison, just over one-third (34 per cent) of participants who were key decision-makers were supportive, with 30 per cent possibly supportive and 36 per cent not supportive. Among key decision-makers, males were more likely to be supportive (p = 0.009). The top three perceived advantages of supervising a student were: opportunity to mentor early career development, opportunity to give back to the profession and future recruitment. The top three perceived disadvantages were: burden on time, decrease in number of patients examined and burden on support staff. Suggested incentives for supervising students were credit for continuing professional development and financial remuneration. There appears to be moderate support for extended clinical placement programs; however, there are incentives that might engage a larger proportion of the profession in the future. These findings can inform the development of effective and sustainable clinical training programs for optometry students. Additionally

  1. Using a Regression Discontinuity Design to Estimate the Impact of Placement Decisions in Developmental Math

    Science.gov (United States)

    Melguizo, Tatiana; Bos, Johannes M.; Ngo, Federick; Mills, Nicholas; Prather, George

    2016-01-01

    This study evaluates the effectiveness of math placement policies for entering community college students on these students' academic success in math. We estimate the impact of placement decisions by using a discrete-time survival model within a regression discontinuity framework. The primary conclusion that emerges is that initial placement in a…

  2. Characterizing performances of solder paste printing process at flexible manufacturing lines

    International Nuclear Information System (INIS)

    Siew, Jit Ping; Low, Heng Chin; Teoh, Ping Chow

    2015-01-01

    Solder paste printing (SPP) has been a challenge on printed circuit board (PCB) manufacturing, evident by the proliferation of solder paste inspection equipment, or substituted by rigorous non-value added activity of manual inspections. The objective of this study is to characterize the SPP performance of various products manufactured in flexible production lines with different equipment configurations, and determine areas for process improvement. The study began by collecting information on SPP performance relative to component placement (CP) process, and to the proportion of mixed products. Using a clustering algorithm to group similar elements together, SPP performance across all product-production line pairs are statistically modeled to discover the trend and the influential factors. The main findings are: (a) Ratio of overall dpku for CP and SPP processes are 2:1; (b) logistic regression models of SPP performance indicated that only effects of product-production line and solder paste printer configuration are significant; (c) PCB circuitry design with BGA components and single solder paste printer line configurations generated the highest monthly defects, with the highest variation in the latter

  3. Characterizing performances of solder paste printing process at flexible manufacturing lines

    Energy Technology Data Exchange (ETDEWEB)

    Siew, Jit Ping; Low, Heng Chin [University of Science Malaysia, 11800 Minden, Penang (Malaysia); Teoh, Ping Chow [Wawasan Open University, 54 Jalan Sultan Ahmad Shah, 10050 Penang (Malaysia)

    2015-02-03

    Solder paste printing (SPP) has been a challenge on printed circuit board (PCB) manufacturing, evident by the proliferation of solder paste inspection equipment, or substituted by rigorous non-value added activity of manual inspections. The objective of this study is to characterize the SPP performance of various products manufactured in flexible production lines with different equipment configurations, and determine areas for process improvement. The study began by collecting information on SPP performance relative to component placement (CP) process, and to the proportion of mixed products. Using a clustering algorithm to group similar elements together, SPP performance across all product-production line pairs are statistically modeled to discover the trend and the influential factors. The main findings are: (a) Ratio of overall dpku for CP and SPP processes are 2:1; (b) logistic regression models of SPP performance indicated that only effects of product-production line and solder paste printer configuration are significant; (c) PCB circuitry design with BGA components and single solder paste printer line configurations generated the highest monthly defects, with the highest variation in the latter.

  4. Post graduate clinical placements: evaluating benefits and challenges with a mixed methods cross sectional design.

    Science.gov (United States)

    Yiend, Jenny; Tracy, Derek K; Sreenan, Brian; Cardi, Valentina; Foulkes, Tina; Koutsantoni, Katerina; Kravariti, Eugenia; Tchanturia, Kate; Willmott, Lucy; Shergill, Sukhi; Reedy, Gabriel

    2016-02-16

    Systematic evaluations of clinical placements are rare, especially when offered alongside academic postgraduate courses. An evidence-based approach is important to allow pedagogically-driven provision, rather than that solely governed by opinion or market demand. Our evaluation assessed a voluntary clinical placement scheme allied to a mental health course. Data were collected over academic years 2010/11- 2013/14, from participating students (n = 20 to 58) and clinician supervisors (n = 10-12), using a mixed-methods cross-sectional design. Quantitative evaluation captured information on uptake, dropout, resource use, attitudes and experience, using standardized (the Placement Evaluation Questionnaire; the Scale To Assess the Therapeutic Relationship - Clinical version and the University of Toronto Placement Supervisor Evaluation) and bespoke questionnaires and audit data. Qualitative evaluation comprised two focus groups (5 clinicians, 5 students), to investigate attitudes, experience, perceived benefits, disadvantages and desired future developments. Data were analysed using framework analysis to identify a priori and emergent themes. High uptake (around 70 placements per annum), low dropout (2-3 students per annum; 5 %) and positive focus group comments suggested placements successfully provided added value and catered sufficiently to student demand. Students' responses confirmed that placements met expectations and the perception of benefit remained after completion with 70 % (n = 14) reporting an overall positive experience, 75 % (n = 15) reporting a pleasant learning experience, 60 % (n = 12) feeling that their clinical skills were enhanced and 85 % (n = 17) believing that it would benefit other students. Placements contributed the equivalent of seven full time unskilled posts per annum to local health care services. While qualitative data revealed perceived 'mutual benefit' for both students and clinicians, this was qualified by

  5. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  6. Effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats.

    Science.gov (United States)

    Mair, A; Martinez-Taboada, F; Nitzan, M

    2017-01-14

    This study aimed to evaluate the effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats. Following anaesthetic induction, the following pulse oximeter probe configurations were performed: no gauze swab (control), placement of a gauze swab between the tongue and the probe, placement of different thicknesses of gauze swab, placement of red cotton fabric, placement of a sheet of white paper and placement of the probe and gauze swab on different locations on the tongue. Oxygen saturation (SpO 2 ) and peripheral perfusion index (PI) were recorded. Placement of a gauze swab between the pulse oximeter probe and the tongue in anaesthetised dogs and cats resulted in significantly higher SpO 2 values compared with the control group. In dogs, PI values were significantly higher than the control in all groups except the quarter thickness swab group. In cats, PI was significantly higher in the double thickness swab and white paper groups compared with the control. Cats had significantly higher SpO 2 and lower PI values than dogs. The authors propose that increased contact pressure is responsible for significantly higher SpO 2 and PI readings with the use of a lingual gauze swab resulting from changes in transmural pressure and arterial compliance. British Veterinary Association.

  7. Social learning in a longitudinal integrated clinical placement.

    Science.gov (United States)

    Roberts, Chris; Daly, Michele; Held, Fabian; Lyle, David

    2017-10-01

    Recent research has demonstrated that longitudinal integrated placements (LICs) are an alternative mode of clinical education to traditional placements. Extended student engagement in community settings provide the advantages of educational continuity as well as increased service provision in underserved areas. Developing and maintaining LICs require a differing approach to student learning than that for traditional placements. There has been little theoretically informed empirical research that has offered explanations of which are the important factors that promote student learning in LICs and the relationships between those factors. We explored the relationship between student learning, student perceptions of preparedness for practice and student engagement, in the context of a rural LIC. We used a sequential qualitative design employing thematic, comparative and relational analysis of data from student interviews (n = 18) to understand possible processes and mechanisms of student learning in the LIC. Through the theoretical lens of social learning systems, we identified two major themes; connectivity and preparedness for practice. Connectivity described engagement and relationship building by students, across formal and informal learning experiences, interprofessional interactions, social interactions with colleagues, interaction with patients outside of the clinical setting, and the extent of integration in the wider community. Preparedness for practice, reflected students' perceptions of having sufficient depth in clinical skills, personal and professional development, cultural awareness and understanding of the health system, to work in that system. A comparative analysis compared the nature and variation of learning across students. In a relational analysis, there was a positive association between connectivity and preparedness for practice. Connectivity is a powerful enabler of students' agentic engagement, collaboration, and learning within an LIC. It

  8. 76 FR 17963 - Renewal of Agency Information Collection for Application for Job Placement and Training Services...

    Science.gov (United States)

    2011-03-31

    ... Application for Job Placement and Training Services; Request for Comments AGENCY: Bureau of Indian Affairs... information for the Application for Job Placement and Training Services. The information collection is... training program, which provides vocational/technical training, related counseling, guidance, job placement...

  9. Understanding the information and resource needs of UK health and social care placement students.

    Science.gov (United States)

    Callaghan, Lynne; Doherty, Alan; Lea, Susan J; Webster, Daniel

    2008-12-01

    Students on health and social care degree programmes spend 50% of their time on practice placements. Because of the diversity of settings and the need to evidence their work, it is vital to understand the information and resource needs of placement students. The aim of this investigation was to understand the needs of placement students in terms of accessing resources whilst they are in the field in order to inform a guide to meet these needs. Focus groups were conducted with students on midwifery, social work and post-registration health professions degree programmes on three different sites across the region. Data were analysed using Thematic Content Analysis. Three themes emerged from the data: inequality, user education needs and students' solutions and strategies. It is essential to speak to placement students in order to understand their needs in terms of accessing and using library resources. The timing and content of information skills training is key to meeting student needs while on placement.

  10. Relay Placement for FSO Multihop DF Systems With Link Obstacles and Infeasible Regions

    KAUST Repository

    Zhu, Bingcheng; Cheng, Julian; Alouini, Mohamed-Slim; Wu, Lenan

    2015-01-01

    Optimal relay placement is studied for free-space optical multihop communication with link obstacles and infeasible regions. An optimal relay placement scheme is proposed to achieve the lowest outage probability, enable the links to bypass obstacles

  11. Optimal placement and sizing of fixed and switched capacitor banks under non sinusoidal operating conditions

    International Nuclear Information System (INIS)

    Ladjevardi, M.; Masoum, M.A.S.; Fuchs, E.F.

    2004-01-01

    An iterative nonlinear algorithm is generated for optimal sizing and placement of fixed and switched capacitor banks on radial distribution lines in the presence of linear and nonlinear loads. The HARMFLOW algorithm and the maximum sensitivities selection method are used to solve the constrained optimizations problem with discrete variables. To limit the burden of calculations and improve convergence, the problem is decomposed into two subproblems. Objective functions include minimum system losses and capacitor cost while IEEE 519 power quality limits are used as constraints. Results are presented and analyzed for the 18 bus IEEE distorted system. The advantage of the proposed algorithm compared to the previous work is the consideration of harmonic couplings and reactions of actual nonlinear loads of the distribution system

  12. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  13. STUDENT PREDICTION SYSTEM FOR PLACEMENT TRAINING USING FUZZY INFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Rathore

    2017-04-01

    Full Text Available Proposed student prediction system is most vital approach which may be used to differentiate the student data/information on the basis of the student performance. Managing placement and training records in any larger organization is quite difficult as the student number are high; in such condition differentiation and classification on different categories becomes tedious. Proposed fuzzy inference system will classify the student data with ease and will be helpful to many educational organizations. There are lots of classification algorithms and statistical base technique which may be taken as good assets for classify the student data set in the education field. In this paper, Fuzzy Inference system has been applied to predict student performance which will help to identify performance of the students and also provides an opportunity to improve to performance. For instance, here we will classify the student’s data set for placement and non-placement classes.

  14. Can donated media placements reach intended audiences?

    Science.gov (United States)

    Cooper, Crystale Purvis; Gelb, Cynthia A; Chu, Jennifer; Polonec, Lindsey

    2013-09-01

    Donated media placements for public service announcements (PSAs) can be difficult to secure, and may not always reach intended audiences. Strategies used by the Centers for Disease Control and Prevention's (CDC) Screen for Life: National Colorectal Cancer Action Campaign (SFL) to obtain donated media placements include producing a diverse mix of high-quality PSAs, co-branding with state and tribal health agencies, securing celebrity involvement, monitoring media trends to identify new distribution opportunities, and strategically timing the release of PSAs. To investigate open-ended recall of PSAs promoting colorectal cancer screening, CDC conducted 12 focus groups in three U.S. cities with men and women either nearing age 50 years, when screening is recommended to begin, or aged 50-75 years who were not in compliance with screening guidelines. In most focus groups, multiple participants recalled exposure to PSAs promoting colorectal cancer screening, and most of these individuals reported having seen SFL PSAs on television, in transit stations, or on the sides of public buses. Some participants reported exposure to SFL PSAs without prompting from the moderator, as they explained how they learned about the disease. Several participants reported learning key campaign messages from PSAs, including that colorectal cancer screening should begin at age 50 years and screening can find polyps so they can be removed before becoming cancerous. Donated media placements can reach and educate mass audiences, including millions of U.S. adults who have not been screened appropriately for colorectal cancer.

  15. Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system.

    Science.gov (United States)

    Poyanli, Oguz S; Soylemez, Salih; Ozkut, Afsar T; Uygur, Esat; Kemah, Bahattin; Unal, Omer K

    2015-11-01

    We assessed the accuracy of a new guide system that we developed to place lag screws in the proper position with the minimum number of attempts for operative treatment of trochanteric femoral fractures. A total of 55 consecutive trochanteric femoral fractures were treated with a cephalomedullary nail. The first 27 consecutive patients were treated with the standard operation (group A), while the new guide system was used in the last 28 consecutive patients (group B). The numbers of attempts to place K wires and the duration of surgery were noted. Accuracy of lag screw placement was evaluated by measuring the angle of deviation from the central axis of the femoral head. Deviation values ranged from -11̊ to +15̊ for the 27 cases in group A, with a median absolute deviation of 8̊±6̊. That in the 28 cases after the introduction of the new guide system (group B) ranged from -5̊ to +6̊, with a median absolute deviation of 0.5̊±3̊ (Pfractures. The present study indicated that this new guide system and nail facilitate accurate placement of lag screws in the appropriate position with the minimum number of attempts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Temporary placement of stent grafts in postsurgical benign biliary strictures: a single center experience.

    Science.gov (United States)

    Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  17. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  18. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    International Nuclear Information System (INIS)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  19. Private placements

    International Nuclear Information System (INIS)

    Bugeaud, G. J. R.

    1998-01-01

    The principles underlying private placements in Alberta, and the nature of the processes employed by the Alberta Securities Commission in handling such transactions were discussed. The Alberta Securities Commission's mode of operation was demonstrated by the inclusion of various documents issued by the Commission concerning (1) special warrant transactions prior to listing, (2) a decision by the Executive Director refusing to issue a receipt for the final prospectus for a distribution of securities of a company and the reasons for the refusal, (3) the Commission's decision to interfere with the Executive Director's decision not to issue a receipt for the final prospectus, with full citation of the Commission's reasons for its decision, (4) and a series of proposed rules and companion policy statements regarding trades and distributions outside and in Alberta. Text of a sample 'short form prospectus' was also included

  20. Simultaneous Versus Sequential Side-by-Side Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstructions.

    Science.gov (United States)

    Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi

    2017-09-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.

  1. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  2. Confirmation of Essure placement using transvaginal ultrasound

    NARCIS (Netherlands)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent

  3. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  4. 26 CFR 1.414(r)-3 - Separate line of business.

    Science.gov (United States)

    2010-04-01

    ... business must have its own separate management. A line of business has its own separate management only if... houses a centralized procurement, marketing, and billing operation for all of its lines of business. None of the procurement, marketing, or billing employees specializes in any particular line of business...

  5. Reocclusion after Self-Expandable Metallic Stent Placement for Relieving Malignant Colorectal Obstruction as a Palliative Treatment

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2016-12-01

    Full Text Available Self-expandable metallic stent (SEMS placement has been practiced in several hospitals in Japan, including ours, since January 2012. Here, we report the case of an 82-year-old Japanese man who presented to the hospital with a 1-week history of right hypochondrial pain. Computed tomography (CT findings indicated colorectal cancer. The laboratory findings on admission indicated severe anemia (red blood cell count, 426 × 104/μL; hemoglobin, 7.9 g/dL. We performed SEMS placement because the patient refused to undergo surgery. He did not attend any of the scheduled follow-up visits after SEMS placement. However, a year and a half after the SEMS placement, the patient attended the hospital because of difficulty in passing stool. A plain abdominal CT scan showed bowel reobstruction due to the ascending colon cancer after SEMS placement. We performed an emergency operation, ascending colostomy, on the same day. Colorectal stent placement may be a good treatment option for patients who refuse to undergo conventional therapeutic treatments or in those with unresectable colorectal cancer. Patients should be carefully followed up every few months after SEMS placement because of the risk of reocclusion.

  6. Talar anchor placement for modified Brostrom lateral ankle stabilization procedure.

    Science.gov (United States)

    Angirasa, Arush K; Barrett, Michael J

    2008-01-01

    The modified Brostrom procedure has been a proven procedure with excellent utility in the treatment of lateral ankle instability within limitation. Multiple variations of the original technique have been described in the literature to date. Included in these variations are differences in anchor placement, suture technique, or both. In this research study, we propose placing a bone screw anchor into the lateral shoulder of the talus rather than the typical placement at the lateral malleolus for anatomic reconstruction of the lateral ankle ligaments.

  7. Suboccipital neuropathy after bone conduction device placement

    NARCIS (Netherlands)

    Faber, H.T.; Ru, J.A. de

    2013-01-01

    OBJECTIVE: To describe the clinical characteristics of a 70-year-old female with occipital neuropathy following bone conduction device surgery. DESCRIPTION: A 65-year-old woman underwent bone conduction device placement surgery on the left temporal bone. Postoperatively she progressively developed

  8. "This program contains product placement": Effects of sponsorship disclosure on television viewers’ responses

    NARCIS (Netherlands)

    Boerman, S.C.

    2014-01-01

    Television viewers are increasingly exposed to texts saying "This program contains product placement" or PP (short for product placement) logos incorporated in television programs. These so-called sponsorship disclosures aim to inform viewers about advertising that is embedded in television

  9. RJMCMC based Text Placement to Optimize Label Placement and Quantity

    Science.gov (United States)

    Touya, Guillaume; Chassin, Thibaud

    2018-05-01

    Label placement is a tedious task in map design, and its automation has long been a goal for researchers in cartography, but also in computational geometry. Methods that search for an optimal or nearly optimal solution that satisfies a set of constraints, such as label overlapping, have been proposed in the literature. Most of these methods mainly focus on finding the optimal position for a given set of labels, but rarely allow the removal of labels as part of the optimization. This paper proposes to apply an optimization technique called Reversible-Jump Markov Chain Monte Carlo that enables to easily model the removal or addition during the optimization iterations. The method, quite preliminary for now, is tested on a real dataset, and the first results are encouraging.

  10. 75 FR 80067 - Renewal of Agency Information Collection for Application for Job Placement and Training Services...

    Science.gov (United States)

    2010-12-21

    ... Application for Job Placement and Training Services; Request for Comments AGENCY: Bureau of Indian Affairs... Application for Job Placement and Training Services. The information collection is currently authorized by OMB... information collection conducted under 25 CFR part 26 to administer the job placement and training program...

  11. Multidisciplinary treatment of a fractured maxillary central incisor

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Neela

    2017-01-01

    Full Text Available Subgingivally fractured incisors are still a challenge to treat. Restoration of severely damaged teeth requires careful attention and comprehensive preplanned treatment. Here, a patient who had traumatic injury to the upper left central incisor which led to an oblique fracture involving enamel, dental and extending into the root below the gingival margin was saved from extraction by accelerated forced eruption of a root portion, allowing placement of crown, and eliminating the need for a fixed partial denture. A tooth otherwise would have gone for extraction routinely was thus saved and restored through a multidisciplinary approach by a combined orthodontic, periodontal and endodontic treatment.

  12. Disrupted Social Work Field Placement: Factors That Contribute to Premature Termination of BSW Students' Field Placement

    Science.gov (United States)

    Tyler, Janet

    2012-01-01

    According to R. Wayne ("Legal Guidelines for Dismissing Students Because of Poor Performance in the Field," 2004), there is a widely accepted assumption in social work education that field placement provides the best opportunity to evaluate students' goodness-of-fit with the profession and is therefore used to weed out unsuitable…

  13. Eighth Grade Algebra Course Placement and Student Motivation for Mathematics

    Science.gov (United States)

    Simzar, Rahila M.; Domina, Thurston; Tran, Cathy

    2016-01-01

    This study uses student panel data to examine the association between Algebra placement and student motivation for mathematics. Changes in achievement goals, expectancy, and task value for students in eighth grade Algebra are compared with those of peers placed in lower-level mathematics courses (N = 3,306). In our sample, students placed in Algebra reported an increase in performance-avoidance goals as well as decreases in academic self-efficacy and task value. These relations were attenuated for students who had high mathematics achievement prior to Algebra placement. Whereas all students reported an overall decline in performance-approach goals over the course of eighth grade, previously high-achieving students reported an increase in these goals. Lastly, previously high-achieving students reported an increase in mastery goals. These findings suggest that while previously high-achieving students may benefit motivationally from eighth grade Algebra placement, placing previously average- and low-performing students in Algebra can potentially undermine their motivation for mathematics. PMID:26942210

  14. Eighth Grade Algebra Course Placement and Student Motivation for Mathematics.

    Science.gov (United States)

    Simzar, Rahila M; Domina, Thurston; Tran, Cathy

    2016-01-01

    This study uses student panel data to examine the association between Algebra placement and student motivation for mathematics. Changes in achievement goals, expectancy, and task value for students in eighth grade Algebra are compared with those of peers placed in lower-level mathematics courses (N = 3,306). In our sample, students placed in Algebra reported an increase in performance-avoidance goals as well as decreases in academic self-efficacy and task value. These relations were attenuated for students who had high mathematics achievement prior to Algebra placement. Whereas all students reported an overall decline in performance-approach goals over the course of eighth grade, previously high-achieving students reported an increase in these goals. Lastly, previously high-achieving students reported an increase in mastery goals. These findings suggest that while previously high-achieving students may benefit motivationally from eighth grade Algebra placement, placing previously average- and low-performing students in Algebra can potentially undermine their motivation for mathematics.

  15. Association between subjective memory complaints and nursing home placement: a four-year follow-up

    DEFF Research Database (Denmark)

    Waldorff, Frans Boch; Siersma, Volkert; Waldemar, Gunhild

    2009-01-01

    nursing home placements were observed. Subjective memory complaints were associated with an adjusted Hazard Ratio (HR) of 2.59 for nursing home placement. Other statistical significant covariates were MMSE depression...... (HR = 4.74). The effect of subjective memory complaints is seen to moderate when subjects are older. CONCLUSION: The data of this study indicated that in an elderly primary care population the presence of subjective memory complaints was a significant independent predictor for nursing home placement......OBJECTIVE: In order to evaluate whether elderly persons with subjective memory complaints may be regarded as a group of potentially vulnerable patients who need close follow-up, we investigated the risk of nursing home placement during a 4-year follow-up period. METHODS: Prospective cohort survey...

  16. Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting

    Science.gov (United States)

    Thomas, Vimal Koshy; Paul, Cherish; Rajeev, Punchalil Chathappan; Palatty, Babu Urumese

    2017-01-01

    Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capnography and clinical methods. But then, it yielded results considerably faster than the other two modalities. PMID:28584427

  17. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  18. Health-profession students’ teaching and learning expectations in Ugandan medical schools: pre- and postcommunity placement comparison

    Science.gov (United States)

    Wakida, Edith K; Ruzaaza, Gad; Muggaga, Kintu; Akera, Peter; Oria, Hussein; Kiguli, Sarah

    2015-01-01

    Purpose The benefits of community-based medical education for both students and teachers are becoming increasingly clear. However, there is paucity of information about the importance of incorporating students’ thoughts in the community-based education curriculum and the impact it has on their intentions to work in rural communities. The purpose of this study was to assess the teaching and learning expectations before and after placement of health-profession students going for community placement for the first time and make suggestions for improvement of the community-based programs. Methods The study was a cross-sectional survey with both structured and unstructured questions. Participants were recruited from four medical schools in Uganda targeting 100% participation of health-profession students going for community placement in 2014. In total, 454 and 305 participants responded to self-administered questionnaires before and after community placement, respectively; and they were from different programs and years of study. Results Students’ learning expectations before placement, in ranking were: community engagement, interpersonal skills, community diagnosis, clinical skills, lifestyle practices, and patient management. After placement, the order of ranking was: interpersonal skills, community engagement, community diagnosis, lifestyle practices, clinical skills, and patient management. Most of the students had prior rural exposure and expected to do community engagement. However, after community placement they indicated having developed interpersonal skills. The various health-profession students were able to harmoniously work together to achieve a common purpose, which they find difficult to do in a classroom environment. Conclusion Having student teams comprised of different health programs and years of study going for community placement together promoted peer-to-peer mentorship and enhanced team building during community placement. PMID:26677345

  19. Health-profession students' teaching and learning expectations in Ugandan medical schools: pre- and postcommunity placement comparison.

    Science.gov (United States)

    Wakida, Edith K; Ruzaaza, Gad; Muggaga, Kintu; Akera, Peter; Oria, Hussein; Kiguli, Sarah

    2015-01-01

    The benefits of community-based medical education for both students and teachers are becoming increasingly clear. However, there is paucity of information about the importance of incorporating students' thoughts in the community-based education curriculum and the impact it has on their intentions to work in rural communities. The purpose of this study was to assess the teaching and learning expectations before and after placement of health-profession students going for community placement for the first time and make suggestions for improvement of the community-based programs. The study was a cross-sectional survey with both structured and unstructured questions. Participants were recruited from four medical schools in Uganda targeting 100% participation of health-profession students going for community placement in 2014. In total, 454 and 305 participants responded to self-administered questionnaires before and after community placement, respectively; and they were from different programs and years of study. Students' learning expectations before placement, in ranking were: community engagement, interpersonal skills, community diagnosis, clinical skills, lifestyle practices, and patient management. After placement, the order of ranking was: interpersonal skills, community engagement, community diagnosis, lifestyle practices, clinical skills, and patient management. Most of the students had prior rural exposure and expected to do community engagement. However, after community placement they indicated having developed interpersonal skills. The various health-profession students were able to harmoniously work together to achieve a common purpose, which they find difficult to do in a classroom environment. Having student teams comprised of different health programs and years of study going for community placement together promoted peer-to-peer mentorship and enhanced team building during community placement.

  20. North Central Project: Environment act proposal

    International Nuclear Information System (INIS)

    1992-05-01

    Manitoba Hydro proposes to construct a power transmission and distribution line system to connect 12 northern Manitoba communities to the utility's central power grid. The purpose of this North Central Project (NCP) is to provide reliable and unrestricted electric service to remote communities now largely receiving limited diesel-generated power. The NCP is composed of a 138-kV transmission line running ca 350 km from the Kelsey Generating Station, ca 160 km of 25-kV distribution lines, new transformer stations at four communities, upgraded internal distribution systems within the communities, removal of existing diesel stations and restoration of the sites, modifications and additions to the Kelsey switchyard, and a communications system. The NCP is described in detail, including proposed line routes and transformer station locations, rationales for site and route selection, projected impacts on the environment and local societies, and consultations with the communities to be affected. Potential impacts are expected to be modest, with few unmitigable adverse impacts and a number of potentially significant positive benefits. Impact management measures are proposed to prevent or mitigate adverse effects and to create or enhance positive impacts such as local employment of native peoples. 49 figs., 1 tab