WorldWideScience

Sample records for cell operated residential

  1. Operating results and simulations on a fuel cell for residential energy systems

    International Nuclear Information System (INIS)

    Hamada, Yasuhiro; Goto, Ryuichiro; Nakamura, Makoto; Kubota, Hideki; Ochifuji, Kiyoshi

    2006-01-01

    This paper describes the performance evaluation of a polymer electrolyte fuel cell (PEFC) prototype and demonstration experiments of the electric power and domestic hot water system using it from a pragmatic view-point. Three types of demonstration experiments were carried out applying standard electric power and hot water demands. It was shown that the primary energy reduction rate of this system as compared to the conventional system reached up to 24% under double daily start and stop (DSS) operation. The amount of primary energy reduction in experiments using the energy demand of a household in Sapporo in winter exceeded the experimental results of the standard energy demand, demonstrating that the effects of the introduction of a fuel cell in cold regions could be considerable, in particular, during the winter season

  2. Integration of fuel cells into residential buildings

    International Nuclear Information System (INIS)

    Bell, J.M.; Entchev, E.; Gusdorf, J.; Szadkowski, F.; Swinton, M.; Kalbfleisch, W.; Marchand, R.

    2004-01-01

    Integration of small combined heat and power systems (CHP) into residential buildings is challenging as the loads are small, the load diversity is limited and there are a number of unresolved issues concerning sizing, control, peak loads, emergency operation, grid connection and export, etc. Natural Resources Canada has undertaken an initiative to investigate and develop techniques for the integration of small CHP systems into residential buildings using a highly instrumented house modified to allow quick installation and thorough monitoring of CHP integration techniques as well determining the performance of the CHP systems themselves when operating in a house. The first CHP system installed was a Stirling engine residential CHP system. It was used to examine the completeness of the CHP modifications to the house, to evaluate various building integration techniques and to measure the performance of the CHP system itself. The testing demonstrated the modified house to be an excellent facility for the development of CHP building integration techniques and the testing of residential CHP systems. The Stirling engine CHP system was found to operate well and produce meaningful input to the house. A second system (residential fuel cell) is presently being installed and building integration techniques and the performance of the fuel cell will be tested over the coming year. (author)

  3. Policy schemes, operational strategies and system integration of residential co-generation fuel cells

    DEFF Research Database (Denmark)

    Hansen, Lise-Lotte Pade; Schröder, Sascha Thorsten; Münster, Marie

    2013-01-01

    a heat-driven strategy, with and without time-differentiated tariffs, and an electricity price driven strategy for the operation as a virtual power plant. The corresponding support schemes identified cover feed-in tariffs, net metering and feed-in premiums. Additionally, the interplay of the micro......CHP units with the national energy systems has been analysed. Our main findings are that net metering would be an appropriate tool to support FC based microCHP in Denmark, whereas a price premium would be the preferable tool in France and Portugal. Copyright © 2012, Hydrogen Energy Publications, LLC....... Published by Elsevier Ltd. All rights reserved....

  4. PEM - fuel cell system for residential applications

    Energy Technology Data Exchange (ETDEWEB)

    Britz, P. [Viessmann Werke GmbH and Co KG, 35107 Allendorf (Germany); Zartenar, N.

    2004-12-01

    Viessmann is developing a PEM fuel cell system for residential applications. The uncharged PEM fuel cell system has a 2 kW electrical and 3 kW thermal power output. The Viessmann Fuel Processor is characterized by a steam-reformer/burner combination in which the burner supplies the required heat to the steam reformer unit and the burner exhaust gas is used to heat water. Natural gas is used as fuel, which is fed into the reforming reactor after passing an integrated desulphurisation unit. The low temperature (600 C) fuel processor is designed on the basis of steam reforming technology. For carbon monoxide removal, a single shift reactor and selective methanisation is used with noble metal catalysts on monoliths. In the shift reactor, carbon monoxide is converted into hydrogen by the water gas shift reaction. The low level of carbon monoxide at the outlet of the shift reactor is further reduced, to approximately 20 ppm, downstream in the methanisation reactor, to meet PEM fuel cell requirements. Since both catalysts work at the same temperature (240 C), there is no requirement for an additional heat exchanger in the fuel processor. Start up time is less than 30 min. In addition, Viessmann has developed a 2 kW class PEFC stack, without humidification. Reformate and dry air are fed straight to the stack. Due to the dry operation, water produced by the cell reaction rapidly diffuses through the electrolyte membrane. This was achieved by optimising the MEA, the gas flow pattern and the operating conditions. The cathode is operated by an air blower. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  5. Possibility of hydrogen supply by shared residential fuel cell systems for fuel cell vehicles

    Directory of Open Access Journals (Sweden)

    Ono Yusuke

    2017-01-01

    Full Text Available Residential polymer electrolyte fuel cells cogeneration systems (residential PEFC systems produce hydrogen from city gas by internal gas-reformer, and generate electricity, the hot water at the same time. From the viewpoint of the operation, it is known that residential PEFC systems do not continuously work but stop for long time, because the systems generate enough hot water for short operation time. In other words, currently residential PEFC systems are dominated by the amount of hot water demand. This study focuses on the idle time of residential PEFC systems. Since their gas-reformers are free, the systems have potential to produce hydrogen during the partial load operations. The authors expect that residential PEFC systems can take a role to supply hydrogen for fuel cell vehicles (FCVs before hydrogen fueling stations are distributed enough. From this perspective, the objective of this study is to evaluate the hydrogen production potential of residential PEFC systems. A residential PEFC system was modeled by the mixed integer linear programming to optimize the operation including hydrogen supply for FCV. The objective function represents annual system cost to be minimized with the constraints of energy balance. It should be noted that the partial load characteristics of the gas-reformer and the fuel cell stack are taken into account to derive the optimal operation. The model was employed to estimate the possible amount of hydrogen supply by a residential PEFC system. The results indicated that the system could satisfy at least hydrogen demand for transportation of 8000 km which is as far as the average annual mileage of a passenger car in Japan. Furthermore, hydrogen production by sharing a residential PEFC system with two households is more effective to reduce primary energy consumption with hydrogen supply for FCV than the case of introducing PEFC in each household.

  6. Commercialization of residential fuel cell systems at Tokyo Gas

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hisao; Kameyama, Hiromichi; Okamura, Kiyoshi; Nishizaki, Kunihiro

    2007-07-01

    Increased affluence at homes may inevitably bring about increased energy consumption with it and hence increased CO2 emission from the residential sector, which accounts for a substantial share in the overall CO2 emission. Technologies that can reduce CO2 emission without sacrificing comfort of living at home will be critically important to achieve economic prosperity and preservation of the global environment at the same time. The residential fuel cell system is one of those technologies. Tokyo Gas has been engaging in its development cooperating with the manufacturers and has been playing an important role in the design, development and promotion of fuel cell systems with its vast knowledge and experience of end users' energy consumption. The development, demonstration and promotion of fuel cell systems have been strongly supported by the Japanese Government. In 'the Large Scale Demonstration Project', more than 1000 units of polymer electrolyte fuel cells have been installed to existing homes and have demonstrated their energy saving and CO2 emission reduction potential. This paper reports the status of the development of residential fuel cell systems in Japan and the role Tokyo Gas plays in it.

  7. Demonstration of Hydrogen Energy Network and Fuel Cells in Residential Homes

    International Nuclear Information System (INIS)

    Hirohisa Aki; Tetsuhiko Maeda; Itaru Tamura; Akeshi Kegasa; Yoshiro Ishikawa; Ichiro Sugimoto; Itaru Ishii

    2006-01-01

    The authors proposed the setting up of an energy interchange system by establishing energy networks of electricity, hot water, and hydrogen in residential homes. In such networks, some homes are equipped with fuel cell stacks, fuel processors, hydrogen storage devices, and large storage tanks for hot water. The energy network enables the flexible operation of the fuel cell stacks and fuel processors. A demonstration project has been planned in existing residential homes to evaluate the proposal. The demonstration will be presented in a small apartment building. The building will be renovated and will be equipped with a hydrogen production facility, a hydrogen interchange pipe, and fuel cell stacks with a heat recovery device. The energy flow process from hydrogen production to consumption in the homes will be demonstrated. This paper presents the proposed energy interchange system and demonstration project. (authors)

  8. Proton exchange membrane fuel cell for cooperating households: A convenient combined heat and power solution for residential applications

    International Nuclear Information System (INIS)

    Cappa, Francesco; Facci, Andrea Luigi; Ubertini, Stefano

    2015-01-01

    In this paper we compare the technical and economical performances of a high temperature proton exchange membrane fuel cell with those of an internal combustion engine for a 10 kW combined heat and power residential application. In a view of social innovation, this solution will create new partnerships of cooperating families aiming to reduce the energy consumption and costs. The energy system is simulated through a lumped model. We compare, in the Italian context, the total daily operating cost and energy savings of each system with respect to the separate purchase of electricity from the grid and production of the thermal energy through a standard boiler. The analysis is carried out with the energy systems operating with both the standard thermal tracking and an optimized management. The latter is retrieved through an optimization methodology based on the graph theory. We show that the internal combustion engine is much more affected by the choice of the operating strategy with respect to the fuel cell, in terms long term profitability. Then we conduct a net present value analysis with the aim of evidencing the convenience of using a high temperature proton exchange membrane fuel cell for cogeneration in residential applications. - Highlights: • Fuel cells are a feasible and economically convenient solution for residential CHP. • Control strategy is fundamental for the economical performance of a residential CHP. • Flexibility is a major strength of the fuel cell CHP.

  9. Configuring a fuel cell based residential combined heat and power system

    Science.gov (United States)

    Ahmed, Shabbir; Papadias, Dionissios D.; Ahluwalia, Rajesh K.

    2013-11-01

    The design and performance of a fuel cell based residential combined heat and power (CHP) system operating on natural gas has been analyzed. The natural gas is first converted to a hydrogen-rich reformate in a steam reformer based fuel processor, and the hydrogen is then electrochemically oxidized in a low temperature polymer electrolyte fuel cell to generate electric power. The heat generated in the fuel cell and the available heat in the exhaust gas is recovered to meet residential needs for hot water and space heating. Two fuel processor configurations have been studied. One of the configurations was explored to quantify the effects of design and operating parameters, which include pressure, temperature, and steam-to-carbon ratio in the fuel processor, and fuel utilization in the fuel cell. The second configuration applied the lessons from the study of the first configuration to increase the CHP efficiency. Results from the two configurations allow a quantitative comparison of the design alternatives. The analyses showed that these systems can operate at electrical efficiencies of ∼46% and combined heat and power efficiencies of ∼90%.

  10. Budgeting for International Projects: In-Country Business Operations and Long-Term Residential Assignments.

    Science.gov (United States)

    Richey, John B.

    1994-01-01

    A discussion of international sponsored research program administration looks at budgeting, costs, and procedures for both projects with in-country business operations in developing nations and projects with long-term residential assignments. It is intended for university administrators providing new services to faculty working on international…

  11. Solar heating and cooling of residential buildings: sizing, installation and operation of systems. 1980 edition

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This manual was prepared as a text for a training course on solar heating and cooling of residential buildings. The course and text are directed toward sizing, installation, operation, and maintenance of solar systems for space heating and hot water supply, and solar cooling is treated only briefly. (MHR)

  12. Operation and maintenance cost data for residential photovoltaic modules/panels

    Science.gov (United States)

    Oster, J. R., Jr.; Zaremski, D. R., Jr.; Albert, E. M.; Hawkins, S. L.

    1980-01-01

    Costs associated with the operation and maintenance of residential photovoltaic modules and arrays are studied. Six basic topics related to operation and maintenance to photovoltaic arrays are investigated: maintenance; cleaning; panel replacement; gasket repair/replacement; wiring repair/replacement; and termination repair/replacement. The effects of the mounting types (rack mount, stand off mount, direct mount and integral mount) and the installation/replacement type (sequential, partial interruption and independent) are identified and described. Methods of reducing maintenance costs are suggested.

  13. Reliance Cell Operator

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Reliance Cell Operator. Reliance was the only bidder for cellular licences for Assam and NE. Services allowed only in Guwahati and Shillong due to “security reasons”. Only major cities in the country with only one operator.

  14. An energetic-exergetic analysis of a residential CHP system based on PEM fuel cell

    International Nuclear Information System (INIS)

    Barelli, L.; Bidini, G.; Gallorini, F.; Ottaviano, A.

    2011-01-01

    Highlights: → A zero-dimensional of a micro cogenerative (CHP) energy system based on a Proton Exchange Membrane fuel cell (PEMFC) has been developed. → The electrochemical model has been validated with experimental data. → The performances of this CHP system have been evaluated through a series of simulations. → An energy/exergy analysis of the simulation results has allowed to define the PEMFC optimal operating conditions. → The PEMFC optimal operating conditions detected are: 1 atm, 353.15 K and 100% RH. -- Abstract: The use of fuel cell systems for distributed residential power generation represents an interesting alternative to traditional thermoelectric plants due to their high efficiency and the potential recovering of the heat generated by the internal electrochemical reactions. In this paper the study of a micro cogenerative (CHP) energy system based on a Proton Exchange Membrane fuel cell (PEMFC) is reported. With the aim to evaluate the performance and then the feasibility of this non-conventional energy system, in consideration of thermal and electrical basic demand of a multifamily apartment blocks, a zero-dimensional PEMFC model in Aspen Plus environment has been developed. A simulations sequence has been carried out at different operating conditions of the fuel cell (varying temperature, pressure and relative humidity). Subsequently, on the basis of the obtained results, an energy/exergy analysis has been conducted to define the optimal operating conditions of the PEMFC that ensures the most efficient use of the energy and exergy inputs.

  15. Residential CCHP microgrid with load aggregator: Operation mode, pricing strategy, and optimal dispatch

    International Nuclear Information System (INIS)

    Gu, Wei; Lu, Shuai; Wu, Zhi; Zhang, Xuesong; Zhou, Jinhui; Zhao, Bo; Wang, Jun

    2017-01-01

    Highlights: •A bilateral transaction mode for the residential CCHP microgrid is proposed. •An energy pricing strategy for the residential CCHP system is proposed. •A novel integrated demand response for the residential loads is proposed. •Two-stage operation optimization model for the CCHP microgrid is proposed. •Operations of typical days and annual scale of the CCHP microgrid are studied. -- Abstract: As the global energy crisis, environmental pollution, and global warming grow in intensity, increasing attention is being paid to combined cooling, heating, and power (CCHP) systems that realize high-efficiency cascade utilization of energy. This paper proposes a bilateral transaction mechanism between a residential CCHP system and a load aggregator (LA). The variable energy cost of the CCHP system is analyzed, based on which an energy pricing strategy for the CCHP system is proposed. Under this pricing strategy, the electricity price is constant, while the heat/cool price is ladder-shaped and dependent on the relationship between the electrical, heat, and cool loads. For the LA, an integrated demand response program is proposed that combines electricity-load shifting and a flexible heating/cooling supply, in which a thermodynamic model of buildings is used to determine the appropriate range of heating/cooling supply. Subsequently, a two-stage optimal dispatch model is proposed for the energy system that comprises the CCHP system and the LA. Case studies consisting of three scenarios (winter, summer, and excessive seasons) are delivered to demonstrate the effectiveness of the proposed approach, and the performance of the proposed pricing strategy is also evaluated by annual operation simulations.

  16. SOLAR SYSTEMS FOR RESIDENTIAL BUILDINGS IN ACCORDANCE WITH OPERATING CONDITIONS OF THE REPUBLIC OF BELARUS

    Directory of Open Access Journals (Sweden)

    M. A. Rutkowski

    2017-01-01

    Full Text Available Solar systems are actively applied for heat supply of buildings in Europe. Usage of solar energy for heat supply of residential buildings is considered as rather efficient for the Republic of Belarus because total amount of direct and scattered solar radiation entering horizontal surface is equivalent to an average European index for the climate of Belarus. The paper analyzes an existing dependence on determination of solar system efficiency and proposes an amended formula for calculations while designing solar consumption systems and its legitimacy has been experimentally proved. A scheme of an experimental unit with explanations and a brief description for execution of experiments and main results of the completed investigations have been presented in the paper. Experiments have been carried out for solar systems with natural and forced coolant circulation. Attention has been paid to obtaining maximum possible temperature potential of the coolant during operation of the solar system within periods of high and low solar radiation intensity. Recommendations on practical application of solar systems for multi-storey residential buildings houses and mansion-type houses have been given in the paper. The paper presents technological principles of constructing “passive” solar heating devices. A comparison of traditionally applied and proposed alternative solar systems has been made for operational conditions in Belarus. The paper proposes a solar system for hot water supply of multi-storey buildings. The proposed system has found its first realization in the Republic while designing and constructing an energy-efficient demonstration 10-storey residential building in Mogilev within the framework of the UN Development Program project and Global Environment Fund “Improvement of energy efficiency for residential buildings in the Republic of Belarus”

  17. Exergy characteristics of a ceiling-type residential air conditioning system operating under different climatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Arif [Dept. of Mechanical Engineering, Ceyhan Engineering Faculty, Cukurova University, Adana (Turkmenistan)

    2016-11-15

    In this study an energy and exergy analysis of a Ceiling-type residential air conditioning (CTRAC) system operating under different climatic conditions have been investigated for provinces within the different geographic regions of Turkey. Primarily, the hourly cooling load capacities of a sample building (Q{sub evap}) during the months of April, May, June, July, August and September were determined. The hourly total heat gain of the sample building was determined using the Hourly analysis program (HAP). The Coefficient of performance (COP), exergy efficiency (η) and exergy destruction (Ex{sub dest}) values for the whole system and for each component were obtained. The results showed that lower atmospheric temperature (T{sub atm}) influenced the performance of the system and each of its components.

  18. Performance of a residential heat pump operating in the cooling mode with single faults imposed

    International Nuclear Information System (INIS)

    Kim, Minsung; Payne, W. Vance; Domanski, Piotr A.; Yoon, Seok Ho; Hermes, Christian J.L.

    2009-01-01

    The system behavior of a R410A residential unitary split heat pump operating in the cooling mode was investigated. Seven artificial faults were implemented: compressor/reversing valve leakage, improper outdoor air flow, improper indoor air flow, liquid line restriction, refrigerant undercharge, refrigerant overcharge, and presence of non-condensable gas in the refrigerant. This study monitored eight fault detection features and identified the most sensitive features for each fault. The effect of the various fault levels on energy efficiency ratio (EER) was also estimated. Since the studied system employed a thermostatic expansion valve (TXV) as an expansion device, it could adapt to some faults making the fault less detectable. The distinctiveness of the fault depended on the TXV status (fully open or not)

  19. Fuzzy Logic Based Control of Power of PEM Fuel Cell System for Residential Application

    Directory of Open Access Journals (Sweden)

    Khaled MAMMAR

    2009-07-01

    Full Text Available This paper presents a dynamic model of Fuel cell system for residential power generation. The models proposed include a fuel cell stack model, reformer model and DC/AC inverter model. Furthermore a fuzzy logic (FLC controller is used to control active power of PEM fuel cell system. The controller modifies the hydrogen flow feedback from the terminal load. Simulation results confirmed the high performance capability of the fuzzy logic controller to control power generation.

  20. Greenhouse gases emission assessment in residential sector through buildings simulations and operation optimization

    International Nuclear Information System (INIS)

    Stojiljković, Mirko M.; Ignjatović, Marko G.; Vučković, Goran D.

    2015-01-01

    Buildings use a significant amount of primary energy and largely contribute to greenhouse gases emission. Cost optimality and cost effectiveness, including cost-optimal operation, are important for the adoption of energy efficient and environmentally friendly technologies. The long-term assessment of buildings-related greenhouse gases emission might take into account cost-optimal operation of their energy systems. This is often not the case in the literature. Long-term operation optimization problems are often of large scale and computationally intensive and time consuming. This paper formulates a bottom-up methodology relying on an efficient, but precise operation optimization approach, applicable to long-term problems and use with buildings simulations. We suggest moving-horizon short-term optimization to determine near-optimal operation modes and show that this approach, applied to flexible energy systems without seasonal storage, have satisfactory efficiency and accuracy compared with solving problem for an entire year. We also confirm it as a valuable pre-solve technique. Approach applicability and the importance of energy systems optimization are illustrated with a case study considering buildings envelope improvements and cogeneration and heat storage implementation in an urban residential settlement. EnergyPlus is used for buildings simulations while mixed integer linear programming optimization problems are constructed and solved using the custom-built software and the branch-and-cut solver Gurobi Optimizer. - Highlights: • Bottom-up approach for greenhouse gases emission assessment is presented. • Short-term moving-horizon optimization is used to define operation regimes. • Operation optimization and buildings simulations are connected with modeling tool. • Illustrated optimization method performed efficiently and gave accurate results.

  1. Operational energy in the life cycle of residential dwellings: The experience of Spain and Colombia

    International Nuclear Information System (INIS)

    Ortiz, Oscar; Castells, Francesc; Sonnemann, Guido

    2010-01-01

    Life Cycle Assessment (LCA) has been applied within the residential building sector of two buildings, one in each a developed (Spain) and a developing (Colombia) country. The main goal of this paper involves the environmental loads and also brings together the operational energy for activities during the operation phase such as HVAC, domestic hot water, electrical appliances, cooking and illumination. The present research compares two real scenarios: Situation 1, where 100% of the dwelling's energy is supplied with electricity only and Situation 2, where dwellings can be operated with natural gas plus electricity. The results for the environmental impacts using natural gas plus electricity show that of the Spanish environmental impacts air conditioning had the highest impact with approximately 27-42% due to the electricity used to power it. In Colombian results showed that electrical appliances had the highest environmental impacts in the same order of magnitude with approximately 60% and cooking had the best reduction of emissions due to the use of natural gas, from 10% down to less than 2%. The origin of the energy source used in each Country plays an important role to minimize environmental impacts, as was demonstrated by the environmental impacts of its use in Colombia where 78% of the electricity came from hydroelectric plants whereas in Spain it is more mixed, fossil fuels represented 55%, nuclear 18% and wind 9%. In summary, LCA has been applied because this methodology supports the decision making to concern environmental sustainability.

  2. Integrating a hydrogen fuel cell electric vehicle with vehicle-to-grid technology, photovoltaic power and a residential building

    NARCIS (Netherlands)

    Robledo, C.B.; Oldenbroek, V.D.W.M.; Abbruzzese, F.; van Wijk, A.J.M.

    2018-01-01

    This paper presents the results of a demonstration project, including building-integrated photovoltaic (BIPV) solar panels, a residential building and a hydrogen fuel cell electric vehicle (FCEV) for combined mobility and power generation, aiming to achieve a net zero-energy residential building

  3. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  4. Analyses on Cost Reduction and CO2 Mitigation by Penetration of Fuel Cells to Residential Houses

    Science.gov (United States)

    Aki, Hirohisa; Yamamoto, Shigeo; Kondoh, Junji; Murata, Akinobu; Ishii, Itaru; Maeda, Tetsuhiko

    This paper presents analyses on the penetration of polymer electrolyte fuel cells (PEFC) into a group of 10 residential houses and its effects of CO2 emission mitigation and consumers’ cost reduction in next 30 years. The price is considered to be reduced as the penetration progress which is expected to begin in near future. An experimental curve is assumed to express the decrease of the price. Installation of energy interchange systems which involve electricity, gas and hydrogen between a house which has a FC and contiguous houses is assumed to utilize both electricity and heat more efficiently, and to avoid start-stop operation of fuel processor (reformer) as much as possible. A multi-objective model which considers CO2 mitigation and consumers’ cost reduction is constructed and provided a Pareto optimum solution. A solution which simultaneously realizes both CO2 mitigation and consumers’ cost reduction appeared in the Pareto optimum solution. Strategies to reduce CO2 emission and consumers’ cost are suggested from the results of the analyses. The analyses also revealed that the energy interchange systems are effective especially in the early stage of the penetration.

  5. Complex analysis of energy efficiency in operated high-rise residential building: Case study

    Directory of Open Access Journals (Sweden)

    Korniyenko Sergey

    2018-01-01

    Full Text Available Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects. Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.

  6. Complex analysis of energy efficiency in operated high-rise residential building: Case study

    Science.gov (United States)

    Korniyenko, Sergey

    2018-03-01

    Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects). Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.

  7. SMART FUEL CELL OPERATED RESIDENTIAL MICRO-GRID COMMUNITY

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Mohammad S. Alam (PI/PD)

    2005-04-13

    To build on the work of year one by expanding the smart control algorithm developed to a micro-grid of ten houses; to perform a cost analysis; to evaluate alternate energy sources; to study system reliability; to develop the energy management algorithm, and to perform micro-grid software and hardware simulations.

  8. Solid oxide fuel cell systems for residential micro-combined heat and power in the UK: Key economic drivers

    Science.gov (United States)

    Hawkes, Adam; Leach, Matthew

    The ability of combined heat and power (CHP) to meet residential heat and power demands efficiently offers potentially significant financial and environmental advantages over centralised power generation and heat-provision through natural-gas fired boilers. A solid oxide fuel cell (SOFC) can operate at high overall efficiencies (heat and power) of 80-90%, offering an improvement over centralised generation, which is often unable to utilise waste heat. This paper applies an equivalent annual cost (EAC) minimisation model to a residential solid oxide fuel cell CHP system to determine what the driving factors are behind investment in this technology. We explore the performance of a hypothetical SOFC system—representing expectations of near to medium term technology development—under present UK market conditions. We find that households with small to average energy demands do not benefit from installation of a SOFC micro-CHP system, but larger energy demands do benefit under these conditions. However, this result is sensitive to a number of factors including stack capital cost, energy import and export prices, and plant lifetime. The results for small and average dwellings are shown to reverse under an observed change in energy import prices, an increase in electricity export price, a decrease in stack capital costs, or an improvement in stack lifetime.

  9. DOD Residential Proton Exchange Membrane (PEM) Fuel Cell Demonstration Program. Volume 2. Summary of Fiscal Year 2001-2003 Projects

    Science.gov (United States)

    2005-09-01

    produced many of the Beatles 1970s recordings. This facility was selected to host the UK PEM demonstration project from a selection of four potential sites...funded the Department of Defense (DOD) Residential PEM Demonstration Project to demonstrate domestically-produced, residential Proton Exchange Membrane...PEM) fuel cells at DOD Facilities. The objectives were to: (1) assess PEM fuel cells’ role in supporting sustainability at military installations

  10. Photovoltaic Cell Operation on Mars

    Science.gov (United States)

    Landis, Geoffrey A.; Kerslake, Thomas; Jenkins, Phillip P.; Scheiman, David A.

    2004-01-01

    The Martian surface environment provides peculiar challenges for the operation of solar arrays: low temperature, solar flux with a significant scattered component that varies in intensity and spectrum with the amount of suspended atmospheric dust, and the possibility of performance loss due to dust deposition on the array surface. This paper presents theoretical analyses of solar cell performance on the surface of Mars and measurements of cells under Martian conditions.

  11. B cells in operational tolerance.

    Science.gov (United States)

    Chesneau, M; Danger, R; Soulillou, J-P; Brouard, S

    2018-02-16

    Transplantation is currently the therapy of choice for endstage organ failure even though it requires long-term immunosuppresive therapy, with its numerous side effects, for acceptance of the transplanted organ. In rare cases however, patients develop operational tolerance, that is, graft survival without immunosuppression. Studies conducted on these patients reveal genetic, phenotypic, and functional signatures. They provide a better understanding of the immunological mechanisms involved in operational tolerance and define biomarkers that could be used to adapt immunosuppressive treatment to the individual, safely reduce immunosuppression doses, and ideally and safely guide immunosuppression withdrawal. This review summarizes studies that suggest a role for B cells as biomarkers of operational tolerance and discusses the use of B cells as a predictive tool for immunologic risk. Copyright © 2018. Published by Elsevier Inc.

  12. Natural gas–biomass dual fuelled microturbines: Comparison of operating strategies in the Italian residential sector

    International Nuclear Information System (INIS)

    Pantaleo, Antonio M.; Camporeale, Sergio; Shah, Nilay

    2014-01-01

    This paper compares different operating strategies for small scale (100 kWe) combined heat and power (CHP) plants fired by natural gas and solid biomass to serve a residential energy demand. The focus is on a dual fuel micro gas turbine (MGT) cycle. Various biomass/natural gas energy input ratios are modelled, in order to assess the trade-offs between: (i) lower energy conversion efficiency and higher investment cost when increasing the biomass input rate; (ii) higher primary energy savings and revenues from feed-in tariff available for biomass electricity fed into the grid. The strategies of baseload (BL), heat driven (HD) and electricity driven (ED) plant operation are compared, for an aggregate of residential end-users in cold, average and mild climate conditions. On the basis of the results from thermodynamic assessment and simulation at partial load operation, CAPEX and OPEX estimates, and Italian energy policy scenario (incentives available for biomass electricity, on-site and high efficiency CHP), the maximum global energy efficiency, primary energy savings and investment profitability is found, as a function of biomass/natural gas ratio, plant operating strategy and energy demand typology. The thermal and electric conversion efficiency ranged respectively between 46 and 38% and 30 and 19% for the natural gas and biomass fired case studies. The IRR of the investment was highly influenced by the load/CHP thermal power ratio and by the operation mode. The availability of high heat demand levels was also a key factor, to avoid wasted cogenerated heat and maximize CHP sales revenues. BL operation presented the highest profitability because of the higher revenues from electricity sales. Climate area was another important factor, mainly in case of low load/CHP ratios. Moreover, at low load/CHP power ratio and for the BL operation mode, the dual fuel option presented the highest profitability. This is due to the lower cost of biomass fuel in comparison to natural

  13. Combined heat and power generation with fuel cells in residential buildings in the future energy system; Kraft-Waerme-Kopplung mit Brennstoffzellen in Wohngebaeuden im zukuenftigen Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Jungbluth, C.H.

    2007-04-27

    Combined heat and power generation (CHP) is regarded as one of the cornerstones of a future sustainable energy system. The application of this approach can be substantially extended by employing fuel cell technologies in small units for supplying heat to residential buildings. This could create an additional market for combined heat and power generation corresponding to approx. 25% of the final energy demand in Germany today. In parallel, the extensive application of distributed fuel cell systems in residential buildings would have substantial effects on energy infrastructures, primary energy demand, the energy mix and greenhouse gas emissions. It is the aim of the present study to quantify these effects via scenario modelling of energy demand and supply for Germany up to the year 2050. Two scenarios, reference and ecological commitment, are set up, and the application and operation of fuel cell plants in the future stock of residential buildings is simulated by a bottom-up approach. A model of the building stock was developed for this purpose, consisting of 213 types of reference buildings, as well as detailed simulation models of the plant operation modes. The aim was, furthermore, to identify economically and ecologically optimised plant designs and operation modes for fuel cells in residential buildings. Under the assumed conditions of the energy economy, economically optimised plant sizes for typical one- or two-family homes are in the range of a generating capacity of a few hundred watts of electrical power. Plant sizes of 2 to 4.7 kW{sub el} as discussed today are only economically feasible in multifamily dwellings. The abolition of the CHP bonus reduces profitability, especially for larger plants operated by contractors. In future, special strategies for power generation and supply can be an economically useful addition for the heat-oriented operation mode of fuel cells. On the basis of the assumed conditions of the energy economy, a technical potential for

  14. The performance of a residential heat pump operating with a nonazeotropic binary refrigerant mixture

    Science.gov (United States)

    Didion, D.; Mulroy, W.

    Results of laboratory measurement of the performance change of a substantially unmodified residential heat pump designed for 222 when charged with a non azeotropic, binary mixture of R1381 and R152a is presented. Results are presented for various sizes of fixed expansion devices. The effect of gliding temperature in the saturation zone was found to be small. The effect of compositions shift by flash distillation in the accumulator was found to measurably improve low temperature heating performance. It was further observed that some system modification (such as the addition of a receiver) could have further enhanced this low temperature heating performance improvement.

  15. An emerging market in fuel cells? Residential combined heat and power in four countries

    International Nuclear Information System (INIS)

    Brown, J.E.; Hendry, C.N.; Harborne, P.

    2007-01-01

    Global concerns about fossil fuel stocks and security of supply have stimulated governments and industry to explore the development of alternative sources of energy. This has led to the emergence of liberalised markets for energy and the growth of de-centralised generation and distribution systems. Within this context, the use of a sustainable technology, such as fuel cells, as a generator of heat and electricity for the residential market, is a significant market opportunity. Using a set of framework conditions to explain the diffusion of renewable energy technologies, this paper analyses recent developments in four leading industrial countries, and concludes that Japan and Germany are competing to be the lead country for the introduction of this technology. In the process, we highlight the impact of government and the extent to which the development of a fuel cell industry is being driven by incumbent large firms acting independently or in collaboration with a range of other companies across the value chain. [Author

  16. An emerging market in fuel cells? Residential combined heat and power in four countries

    International Nuclear Information System (INIS)

    Brown, James E.; Hendry, Chris N.; Harborne, Paul

    2007-01-01

    Global concerns about fossil fuel stocks and security of supply have stimulated governments and industry to explore the development of alternative sources of energy. This has led to the emergence of liberalised markets for energy and the growth of de-centralised generation and distribution systems. Within this context, the use of a sustainable technology, such as fuel cells, as a generator of heat and electricity for the residential market, is a significant market opportunity. Using a set of framework conditions to explain the diffusion of renewable energy technologies, this paper analyses recent developments in four leading industrial countries, and concludes that Japan and Germany are competing to be the lead country for the introduction of this technology. In the process, we highlight the impact of government and the extent to which the development of a fuel cell industry is being driven by incumbent large firms acting independently or in collaboration with a range of other companies across the value chain

  17. Evaluation of the Field Performance of Residential Fuel Cells: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Torrero, E.; McClelland, R.

    2004-05-01

    Distributed generation has attracted significant interest from rural electric cooperatives and their customers. Cooperatives have a particular nexus because of inherently low customer density, growth patterns at the end of long lines, and an influx of customers and high-tech industries seeking to diversify out of urban environments. Fuel cells are considered a particularly interesting DG candidate for these cooperatives because of their power quality, efficiency, and environmental benefits. The National Rural Electric Cooperative Association Cooperative Research Network residential fuel cell program demonstrated RFC power plants and assessed related technical and application issues. This final subcontract report is an assessment of the program's results. This 3-year program leveraged Department of Energy (DOE) and National Renewable Energy Laboratory (NREL) funding.

  18. Residential and commercial space heating and cooling with possible greenhouse operation; Baca Grande development, San Luis Valley, Colorado. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Goering, S.W.; Garing, K.L.; Coury, G.E.; Fritzler, E.A.

    1980-05-01

    A feasibility study was performed to evaluate the potential of multipurpose applications of moderate-temperature geothermal waters in the vicinity of the Baca Grande community development in the San Luis Valley, Colorado. The project resource assessment, based on a thorough review of existing data, indicates that a substantial resource likely exists in the Baca Grande region capable of supporting residential and light industrial activity. Engineering designs were developed for geothermal district heating systems for space heating and domestic hot water heating for residences, including a mobile home park, an existing motel, a greenhouse complex, and other small commercial uses such as aquaculture. In addition, a thorough institutional analysis of the study area was performed to highlight factors which might pose barriers to the ultimate commercial development of the resource. Finally, an environmental evaluation of the possible impacts of the proposed action was also performed. The feasibility evaluation indicates the economics of the residential areas are dependent on the continued rate of housing construction. If essentially complete development could occur over a 30-year period, the economics are favorable as compared to existing alternatives. For the commercial area, the economics are good as compared to existing conventional energy sources. This is especially true as related to proposed greenhouse operations. The institutional and environmental analyses indicates that no significant barriers to development are apparent.

  19. Outdoor and indoor sources of residential radiofrequency electromagnetic fields, personal cell phone and cordless phone use, and cognitive function in 5-6 years old children

    NARCIS (Netherlands)

    Guxens, Mònica; Vermeulen, Roel; van Eijsden, Manon; Beekhuizen, Johan; Vrijkotte, Tanja G. M.; van Strien, Rob T.; Kromhout, Hans; Huss, Anke

    2016-01-01

    Little is known about the exposure of young children to radiofrequency electromagnetic fields (RF-EMF) and potentially associated health effects. We assessed the relationship between residential RF-EMF exposure from mobile phone base stations, residential presence of indoor sources, personal cell

  20. Modeling and optimization of a heat-pump-assisted high temperature proton exchange membrane fuel cell micro-combined-heat-and-power system for residential applications

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Kær, Søren Knudsen; Nielsen, Mads Pagh

    2015-01-01

    In this study a micro-combined-heat-and-power (micro-CHP) system is coupled to a vapor-compression heat pump to fulfill the residential needs for heating (space heating and water heating) and electricity in detached single-family households in Denmark. Such a combination is assumed to be attractive...... for application, since both fuel cell technology and electric heat pumps are found to be two of the most efficient technologies for generation/conversion of useful energy. The micro-CHP system is fueled with natural gas and includes a fuel cell stack, a fuel processor and other auxiliary components. The micro......-CHP system assumes heat-led operation, to avoid dumping of heat and the use of complicated thermal energy storage. The overall system is grid-interconnected to allow importing and exporting of electricity as necessary. In this study emphasis is given on the operational characterization of the system...

  1. Chapter 6. Operation of electrolytic cell in standard operating practices

    International Nuclear Information System (INIS)

    Yanko, E.A.; Kabirov, Sh.O.; Safiev, Kh.; Azizov, B.S.; Mirpochaev, Kh.A.

    2011-01-01

    This chapter is devoted to operation of electrolytic cell in standard operating practices. Therefore, the electrolyte temperature, the composition of electrolyte, including the level of metals was considered. The regulation of electrolyte composition by liquidus temperature and electrolyte overheating was studied. Damping of anode effects was studied as well. Maintenance of electrolytic cells was described. Heat and energy balances of aluminium electrolytic cells were considered.

  2. Can a web-based community of practice be established and operated to lead falls prevention activity in residential care?

    Science.gov (United States)

    Francis-Coad, Jacqueline; Etherton-Beer, Christopher; Bulsara, Caroline; Nobre, Debbie; Hill, Anne-Marie

    The aims of this study were to evaluate establishing and operating a web-based community of practice (CoP) to lead falls prevention in a residential aged care (RAC) setting. A mixed methods evaluation was conducted in two phases using a survey and transcripts from interactive electronic sources. Nurses and allied health staff (n = 20) with an interest in falls prevention representing 13 sites of an RAC organization participated. In Phase 1, the CoP was developed, and the establishment of its structure and composition was evaluated using determinants of success reported in the literature. In Phase 2, all participants interacted using the web, but frequency of engagement by any participant was low. Participatory barriers, including competing demands from other tasks and low levels of knowledge about information communication technology (ICT) applications, were identified by CoP members. A web-based CoP can be established and operated across multiple RAC sites if RAC management support dedicated time for web-based participation and staff are given web-based training. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Residential greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    The following report examines the technical and economic viability of residential greenhouse additions in Whitehorse, Yukon. The greenhouse was constructed using the south facing wall of an existing residence as a common wall. Total construction costs were $18,000, including labour. Annual fuel demand for the residence has been reduced by about 10 per cent for an annual saving of $425. In addition, produce to the value of $1,000 is grown annually in the greenhouse for domestic consumption and commercial resale. Typically the greenhouse operates for nine months each year. There is a net thermal loss during the months of November, December and January as a result of the large area of glazing. As well as supplementing the heating supply solar greenhouses can provide additional cash crops which can be used to offset the cost of construction. Humidity problems are minimal and can be dealt with by exhausting high humidity air. One system which has been considered for the greenhouse is to use a standard residential heat pump to remove excess moisture and to pump heat into the house. This would have a secondary benefit of excluding the need to circulate greenhouse air through the house. Thus any allergenic reactions to the greenhouse air would be prevented. 8 refs., 3 figs, 2 tabs.

  4. Micro combined heat and power operating on renewable energy for residential building

    International Nuclear Information System (INIS)

    Aoun, Bernard

    2008-01-01

    The building sector consumes more than 43% of the total national energy consumption in France leading to more than 25% of CO 2 emissions associated to this energy consumption. A large number of options exist to limit CO 2 emissions and to improve the performance of buildings. One of these options is developed in this thesis, the use of renewable energies (solar and biomass) in combined production of heat and power. Conventional systems of combined heat and power production are briefly analyzed. The major part of this work has been focused on the development of a micro-CHP system based on an organic Rankine cycle operating on renewable energies intermittent and non-intermittent (solar and wood). The working fluids have been analyzed to allow reaching high thermodynamic performance. The different promising technologies, for each components of the system are identified, depending on the working fluid. A special test bench has been designed and realized to test and characterize an oil-free vapor scroll expander suitable for our application. The different components have been sized using computerized tools developed for the modeling of the Organic Rankine cycle. A dynamic simulation tool has been developed to simulate the annual performance of the micro-CHP system operating under different climate conditions and thermal loads. Results show that the micro-CHP system could save more than 40% of the primary energy consumption and up to 60% of CO 2 emissions. The Levelized electricity cost has been calculated using economic analysis; results show that the electricity cost (50 c-euros/kWhel) is still high compared to other technologies. (author)

  5. A designated centre for people with disabilities operated by Dara Residential Services, Kildare

    LENUS (Irish Health Repository)

    Rauch, Jens

    2011-10-28

    Abstract Protein phosphorylation participates in the regulation of all fundamental biological processes, and protein kinases have been intensively studied. However, while the focus was on catalytic activities, accumulating evidence suggests that non-catalytic properties of protein kinases are essential, and in some cases even sufficient for their functions. These non-catalytic functions include the scaffolding of protein complexes, the competition for protein interactions, allosteric effects on other enzymes, subcellular targeting, and DNA binding. This rich repertoire often is used to coordinate phosphorylation events and enhance the specificity of substrate phosphorylation, but also can adopt functions that do not rely on kinase activity. Here, we discuss such kinase independent functions of protein and lipid kinases focussing on kinases that play a role in the regulation of cell proliferation, differentiation, apoptosis, and motility.

  6. Operating a fuel cell using landfill gas

    Energy Technology Data Exchange (ETDEWEB)

    Trippel, C.E.; Preston, J.L. Jr.; Trocciola, J.; Spiegel, R.

    1996-12-31

    An ONSI PC25{trademark}, 200 kW (nominal capacity) phosphoric acid fuel cell operating on landfill gas is installed at the Town of Groton Flanders Road landfill in Groton, Connecticut. This joint project by the Connecticut Light & Power Company (CL&P) which is an operating company of Northeast Utilities, the Town of Groton, International Fuel Cells (IFC), and the US EPA is intended to demonstrate the viability of installing, operating and maintaining a fuel cell operating on landfill gas at a landfill site. The goals of the project are to evaluate the fuel cell and gas pretreatment unit operation, test modifications to simplify the GPU design and demonstrate reliability of the entire system.

  7. Residential Fuel Cell Demonstration Handbook: National Rural Electric Cooperative Association Cooperative Research Network

    Energy Technology Data Exchange (ETDEWEB)

    Torrero, E.; McClelland, R.

    2002-07-01

    This report is a guide for rural electric cooperatives engaged in field testing of equipment and in assessing related application and market issues. Dispersed generation and its companion fuel cell technology have attracted increased interest by rural electric cooperatives and their customers. In addition, fuel cells are a particularly interesting source because their power quality, efficiency, and environmental benefits have now been coupled with major manufacturer development efforts. The overall effort is structured to measure the performance, durability, reliability, and maintainability of these systems, to identify promising types of applications and modes of operation, and to assess the related prospect for future use. In addition, technical successes and shortcomings will be identified by demonstration participants and manufacturers using real-world experience garnered under typical operating environments.

  8. Computer control of shielded cell operations

    International Nuclear Information System (INIS)

    Jeffords, W.R. III.

    1987-01-01

    This paper describes in detail a computer system to remotely control shielded cell operations. System hardware, software, and design criteria are discussed. We have designed a computer-controlled buret that provides a tenfold improvement over the buret currently in service. A computer also automatically controls cell analyses, calibrations, and maintenance. This system improves conditions for the operators by providing a safer, more efficient working environment and is expandable for future growth and development

  9. Draft, development and optimization of a fuel cell system for residential power generation with steam reformer; Entwurf, Aufbau und Optimierung eines PEM-Brennstoffzellensystems zur Hausenergieversorgung mit Dampfreformer

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, H

    2006-05-17

    The first development cycle of a residential power generation system is described. A steam reformer was chosen to produce hydrogen out of natural gas. After carbon monoxide purification with a preferential oxidation (PrOx) unit the hydrogen rich reformat gas is feed to the anode of the PEM-fuel cell, where due to the internal reaction with air oxygen form the cathode side water, heat and electricity is produced. Due to an incomplete conversion the anode off gas contains hydrogen and residual methane, which is feed to the burner of the steam reformer to reduce the needed amount of external fuel to heat the steam reformer. To develop the system the components are separately investigated and optimized in their construction or operation to meet the system requirements. After steady state and dynamic characterization of the components they were coupled one after another to build the system. To operate the system a system control was developed to operate and characterize this complex system. After characterization the system was analyzed for further optimization. During the development of the system inventions like a water cooled PrOx, an independent fuel cell controller or a burner for anodic off gas recirculation were made. The work gives a look into the interactions between the components and allows to understand the problems by coupling such components. (orig.)

  10. Modeling and off-design performance of a 1 kWe HT-PEMFC (high temperature-proton exchange membrane fuel cell)-based residential micro-CHP (combined-heat-and-power) system for Danish single-family households

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2011-01-01

    A novel proposal for the modeling and operation of a micro-CHP (combined-heat-and-power) residential system based on HT-PEMFC (High Temperature-Proton Exchange Membrane Fuel Cell) technology is described and analyzed to investigate its commercialization prospects. An HT-PEMFC operates at elevated...... temperatures, as compared to Nafion-based PEMFCs and therefore can be a significant candidate for cogeneration residential systems. The proposed system can provide electric power, hot water, and space heating for a typical Danish single-family household. A complete fuel processing subsystem, with all necessary...

  11. A natural-gas fuel processor for a residential fuel cell system

    Science.gov (United States)

    Adachi, H.; Ahmed, S.; Lee, S. H. D.; Papadias, D.; Ahluwalia, R. K.; Bendert, J. C.; Kanner, S. A.; Yamazaki, Y.

    A system model was used to develop an autothermal reforming fuel processor to meet the targets of 80% efficiency (higher heating value) and start-up energy consumption of less than 500 kJ when operated as part of a 1-kWe natural-gas fueled fuel cell system for cogeneration of heat and power. The key catalytic reactors of the fuel processor - namely the autothermal reformer, a two-stage water gas shift reactor and a preferential oxidation reactor - were configured and tested in a breadboard apparatus. Experimental results demonstrated a reformate containing ∼48% hydrogen (on a dry basis and with pure methane as fuel) and less than 5 ppm CO. The effects of steam-to-carbon and part load operations were explored.

  12. The PEM fuel cell as a residential power source; Die PEMFC in der Hausenergieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Gummert, G [HGC Hamburg Gas Consult GmbH, Hamburg (Germany)

    1999-12-31

    The firm HGC, Hamburg Gas Consult GmbH, has been offering CHP systems based on fuel cells since 1996. There still is only one series product on the market, the 200 kW{sub el} or 220 kW{sub th} PC 25 system produced by ONSI, South Windsor, USA. Seven phosphoric acid fuel cell-driven CHPs with a total capacity of 1.4 MW{sub el} have been designed, installed and put into operation by the HGC engineers. Whereas the PC 25 system of ONSI is optimal for applications such as integration into a local heating network, fabrication of small-size phosphoric acid fuel cell systems with a capacity of just 50 kW{sub el} has been found to be non-profitable. For applications requiring 50 kW{sub el} or less, another fuel cell type is much more promising: the polymer electrolyte membrane fuel cell (PEMFC). (orig./CB) [Deutsch] Seit 1996 bietet die HGC Hamburg Gas Consult GmbH Kraft-Waermekopplung mit Brennstoffzellen an. Das einzige Serienprodukt ist damals wie heute die bei der Fa. ONSI in South Windsor, USA, gebaute PC 25 mit 200 kW{sub el} und 220 kW{sub th}. Sieben phosphorsaure Brennstoffzellen-BHKW mit einer Gesamtleistung von 1,4 MW{sub el} wurden bereits von den HGC-Ingenieuren geplant, installiert und in Betrieb genommen. Waehrend die ONSI PC 25 ideal als Blockheizkraftwerk an einem Nahwaermenetz eingesetzt werden kann, rentiert sich die Herstellung kleinerer phosphorsaurer Brennstoffzellenaggregate z.B. mit 50 kW{sub el} Leistung nicht. Fuer Anwendungen im Bereich <50 kW{sub el} bietet sich deshalb ein anderer Brennstoffzellentyp an: Die Polymer Electrolyt Membran Brennstoffzelle (PFMFC). (orig.)

  13. Residential Care

    Science.gov (United States)

    ... Kids For Teens For Parents & Teachers Resolving Family Conflicts The Holidays and Alzheimer's Glossary Virtual Library Online ... longer an option Costs Choosing a care setting Types of residential care A good long-term care ...

  14. A New Cogeneration Residential System Based on Solid Oxide Fuel Cells for a Northern European Climate

    DEFF Research Database (Denmark)

    Vialetto, Giulio; Rokni, Masoud

    2015-01-01

    of them received subsidies to increase installation and reduce cost. This article presents an innovative cogeneration system based on a solid oxide fuel cell (SOFC) system and heat pump for household applications with a focus on primary energy and economic savings using electric equivalent load parameter...... which is a function of the electricity and heat demand of the user, and allows different operation strategies to be considered. The proposal is to maximize the efficiency of the system and to make it profitable, even though technologies with a high purchase cost are considered. Simulations of the system...... are performed under different strategies at a resort located in a northern European climate (Denmark) to cover electricity, space heating and domestic hot water (DHW) demands. The results of these simulations are analyzed with thermodynamic and techno-economic benchmarks, considering different economic...

  15. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source......, but such studies are very expensive if fair representation of both spatial and temporal variations should be obtained. In addition, onsite studies may affect the waste generation in the residence because of the increased focus on the issue. Residential waste is defined in different ways in different countries...

  16. Optimal design and operation of solid oxide fuel cell systems for small-scale stationary applications

    Science.gov (United States)

    Braun, Robert Joseph

    The advent of maturing fuel cell technologies presents an opportunity to achieve significant improvements in energy conversion efficiencies at many scales; thereby, simultaneously extending our finite resources and reducing "harmful" energy-related emissions to levels well below that of near-future regulatory standards. However, before realization of the advantages of fuel cells can take place, systems-level design issues regarding their application must be addressed. Using modeling and simulation, the present work offers optimal system design and operation strategies for stationary solid oxide fuel cell systems applied to single-family detached dwellings. A one-dimensional, steady-state finite-difference model of a solid oxide fuel cell (SOFC) is generated and verified against other mathematical SOFC models in the literature. Fuel cell system balance-of-plant components and costs are also modeled and used to provide an estimate of system capital and life cycle costs. The models are used to evaluate optimal cell-stack power output, the impact of cell operating and design parameters, fuel type, thermal energy recovery, system process design, and operating strategy on overall system energetic and economic performance. Optimal cell design voltage, fuel utilization, and operating temperature parameters are found using minimization of the life cycle costs. System design evaluations reveal that hydrogen-fueled SOFC systems demonstrate lower system efficiencies than methane-fueled systems. The use of recycled cell exhaust gases in process design in the stack periphery are found to produce the highest system electric and cogeneration efficiencies while achieving the lowest capital costs. Annual simulations reveal that efficiencies of 45% electric (LHV basis), 85% cogenerative, and simple economic paybacks of 5--8 years are feasible for 1--2 kW SOFC systems in residential-scale applications. Design guidelines that offer additional suggestions related to fuel cell

  17. Large remote manipulator operating and maintenance experience at IEM cell

    International Nuclear Information System (INIS)

    Hicks, D.F.; McGuinness, P.W.

    1985-01-01

    The Interim Examination and Maintenance (IEM) Cell at the Fast Flux Test Facility (FFTF) has two large Electro-Mechanical Manipulators (EMM's). These manipulators are used for cell operations (processing of reactor core components) as well as general cell maintenance. From our eleven years of operation and maintenance experience with these large EMM's, we have learned many lessons concerning manipulator design. This paper describes the IEM Cell EMM design features and discusses operating and maintenance experience at the IEM Cell

  18. Analysis of a fuel cell on-site integrated energy system for a residential complex

    Science.gov (United States)

    Simons, S. N.; Maag, W. L.

    1979-01-01

    The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

  19. Residential Systems Based on Solid Oxide Fuel Cells for Scandinavian Climate

    DEFF Research Database (Denmark)

    Rokni, Masoud; Vialetto, Giulio

    2015-01-01

    which is a function of the electricity and heat demand of the user, and allows different operation strategies to be considered. The proposal is to maximize the efficiency of the system and to make it profitable, even though technologies with a high purchase cost are considered. Simulations of the system...... scenarios. The calculations show the high primary energy saving and profitability of the system....

  20. Device operation of organic tandem solar cells

    NARCIS (Netherlands)

    Hadipour, A.; de Boer, B.; Blom, P. W. M.

    2008-01-01

    A generalized methodology is developed to obtain the current-voltage characteristic of polymer tandem solar cells by knowing the electrical performance of both sub cells. We demonstrate that the electrical characteristics of polymer tandem solar cells are correctly predicted for both the series and

  1. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  2. Method of operating a direct dme fuel cell system

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a method of operating a fuel cell system comprising one or more fuel cells with a proton exchange membrane, wherein the membrane is composed of a polymeric material comprising acid-doped polybenzimidazole (PBI). The method comprises adjusting the operating...

  3. A Method of Operating a Fuel Cell

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a method of determining the net water drag coefficient (rd) in a fuel cell. By measuring the velocity of the fluid stream at the outlet of the anode, rd can be determined. Real time monitoring and adjustments of the water balance of a fuel cell may be therefore...

  4. Pressurized Operation of a Planar Solid Oxide Cell Stack

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Sun, Xiufu; Ebbesen, Sune Dalgaard

    2016-01-01

    , pressurized SOEC based electrolyzers can become more efficient both energy- and cost-wise than PEM and Alkaline systems. Pressurization of SOFCs can significantly increase the cell power density and reduce the size of auxiliary components. In the present study, a SOC stack was successfully operated......Solid oxide cells (SOCs) can be operated either as fuel cells (SOFC) to convert fuels to electricity or as electrolyzers (SOEC) to convert electricity to fuels such as hydrogen or methane. Pressurized operation of SOCs provide several benefits on both cell and system level. If successfully matured...

  5. Analysis of Operating Temperature of the Polycrystalline Solar Cell

    Directory of Open Access Journals (Sweden)

    Vladimír GÁLL

    2017-12-01

    Full Text Available This work deals with the solar cells with orientation on the calculation of operating temperature of the polycrystalline solar cell, which is under actual load. Operating conditions have a significant effect on the efficiency of solar cells. In the summer with increasing temperature, the efficiency decreases. In the winter, efficiency and output voltage are rising. The operating temperature is determined by intensity of solar radiation, the types of materials used by construction and operating condition. The aim of this work was simplify of the calculation of operating temperature of solar cells. The result of this work is a derived equation that allows a more accurate and faster calculation this temperature with using Matlab software.

  6. Wide Operating Voltage Range Fuel Cell Battery Charger

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gokhan

    2014-01-01

    DC-DC converters for fuel cell applications require wide voltage range operation due to the unique fuel cell characteristic curve. Primary parallel isolated boost converter (PPIBC) is a boost derived topology for low voltage high current applications reaching an efficiency figure up to 98...... by two the converter input-to-output voltage gain. This allows covering the conditions when the fuel cell stack operates in the activation region (maximum output voltage) and increases the degrees of freedom for converter optimization. The transition between operating modes is studied because represents...

  7. Intra- and inter-individual variability of Aspergillus fumigatus reactive T-cell frequencies in healthy volunteers in dependency of mould exposure in residential and working environment.

    Science.gov (United States)

    Wurster, Sebastian; Weis, Philipp; Page, Lukas; Helm, Johanna; Lazariotou, Maria; Einsele, Hermann; Ullmann, Andrew J

    2017-10-01

    Invasive aspergillosis remains a deadly disease in immunocompromised patients, whereas the combination of an exaggerated immune response and continuous exposure lead to various hyperinflammatory diseases. This pilot study aimed to gain an overview of the intra- and inter-individual variability in Aspergillus fumigatus reactive T-helper cells in healthy adults and the correlation with environmental mould exposure. In this flow cytometric study, the frequencies of CD154 + A. fumigatus reactive T cells were evaluated in 70 healthy volunteers. All subjects completed a standardised questionnaire addressing their mould exposure. Subjects with intensive mould exposure in their professional or residential surrounding demonstrated considerably higher mean frequencies of A. fumigatus reactive T-helper and T-memory cells. Comparative evaluation of multiple measurements over time demonstrated relatively conserved reactive T-cell frequencies in the absence of major changes to the exposure profile, whereas those frequently exposed in professional environment or with changes to their risk score demonstrated a marked dependency of antigen reactive T-cell frequencies on recent mould exposure. This pilot study was the first to provide data on the intra-individual variability in A. fumigatus reactive T-cell frequencies and its linkage to mould encounter. Fungus reactive T cells are to be considered a valued tool for the assessment of environmental mould exposure. © 2017 Blackwell Verlag GmbH.

  8. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  9. Micro-CHP systems for residential applications

    International Nuclear Information System (INIS)

    Paepe, Michel de; D'Herdt, Peter; Mertens, David

    2006-01-01

    Micro-CHP systems are now emerging on the market. In this paper, a thorough analysis is made of the operational parameters of 3 types of micro-CHP systems for residential use. Two types of houses (detached and terraced) are compared with a two storey apartment. For each building type, the energy demands for electricity and heat are dynamically determined. Using these load profiles, several CHP systems are designed for each building type. Data were obtained for two commercially available gas engines, two Stirling engines and a fuel cell. Using a dynamic simulation, including start up times, these five system types are compared to the separate energy system of a natural gas boiler and buying electricity from the grid. All CHP systems, if well sized, result in a reduction of primary energy use, though different technologies have very different impacts. Gas engines seem to have the best performance. The economic analysis shows that fuel cells are still too expensive and that even the gas engines only have a small internal rate of return (<5%), and this only occurs in favourable economic circumstances. It can, therefore, be concluded that although the different technologies are technically mature, installation costs should at least be reduced by 50% before CHP systems become interesting for residential use. Condensing gas boilers, now very popular in new homes, prove to be economically more interesting and also have a modest effect on primary energy consumption

  10. Principles and operation of crystalline and amorphous silicon solar cells

    International Nuclear Information System (INIS)

    Chambouleyron, I.

    1983-01-01

    This paper deals with the fundamental aspects of photovoltaic energy conversion. Crystalline silicon solar cell physics together with design criteria and conversion losses are discussed. The general properties of hydrogenated amorphous silicon and the principles of a-Si:H solar cell operation are briefly reviewed. New trends in amorphous materials of photovoltaic interest and novel device structures are finally presented. (Author) [pt

  11. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  12. Development of Residential SOFC Cogeneration System

    International Nuclear Information System (INIS)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-01-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the 'Demonstrative Research on Solid Oxide Fuel Cells' Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  13. Polymer electrolyte fuel cells: flow field for efficient air operation

    Energy Technology Data Exchange (ETDEWEB)

    Buechi, F N; Tsukada, A; Haas, O; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    A new flow field was designed for a polymer electrolyte fuel cell stack with an active area of 200 cm{sup 2} for operation at low air stoichiometry and low air over pressure. Optimum of gas flow and channel dimensions were calculated based on the required pressure drop in the fluid. Single cells and a bi-cell stack with the new flow field show an improved current/voltage characteristic when operated at low air stoichiometries as compared to that of the previous non optimized design. (author) 4 figs., 3 refs.

  14. Modeling and simulation of a residential micro-CHP system based on HT-PEMFC technology

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2009-01-01

    Combined-heat-and-power (CHP) technology is a well known and proved method to produce simultaneously power and heat at high efficiencies. This can be further improved by the introduction of a novel micro-CHP residential system based on High Temperature-Proton Exchange Membrane Fuel Cell (HT-PEMFC......). The HT-PEMFC (based on PBI-membrane technology) operates at temperatures near 200oC, and this can be an ideal match for cogeneration residential systems. The proposed system provides electric power, hot water, and space heating for a typical household (1-5 kWe, 5-10 kWth). The micro-CHP system...

  15. System for controlling the operating temperature of a fuel cell

    Science.gov (United States)

    Fabis, Thomas R.; Makiel, Joseph M.; Veyo, Stephen E.

    2006-06-06

    A method and system are provided for improved control of the operating temperature of a fuel cell (32) utilizing an improved temperature control system (30) that varies the flow rate of inlet air entering the fuel cell (32) in response to changes in the operating temperature of the fuel cell (32). Consistent with the invention an improved temperature control system (30) is provided that includes a controller (37) that receives an indication of the temperature of the inlet air from a temperature sensor (39) and varies the heat output by at least one heat source (34, 36) to maintain the temperature of the inlet air at a set-point T.sub.inset. The controller (37) also receives an indication of the operating temperature of the fuel cell (32) and varies the flow output by an adjustable air mover (33), within a predetermined range around a set-point F.sub.set, in order to maintain the operating temperature of the fuel cell (32) at a set-point T.sub.opset.

  16. Solid oxide fuel cell performance under severe operating conditions

    DEFF Research Database (Denmark)

    Koch, Søren; Hendriksen, P.V.; Mogensen, Mogens Bjerg

    2006-01-01

    The performance and degradation of Solid Oxide Fuel Cells (SOFC) were studied under severe operating conditions. The cells studied were manufactured in a small series by ECN, in the framework of the EU funded CORE-SOFC project. The cells were of the anode-supported type with a double layer LSM...... cathode. They were operated at 750 °C or 850 °C in hydrogen with 5% or 50% water at current densities ranging from 0.25 A cm–2 to 1 A cm–2 for periods of 300 hours or more. The area specific cell resistance, corrected for fuel utilisation, ranged between 0.20 Ω cm2 and 0.34 Ω cm2 at 850 °C and 520 m......V, and between 0.51 Ω cm2 and 0.92 Ω cm2 at 750 °C and 520 mV. The degradation of cell performance was found to be low (ranging from 0 to 8%/1,000 hours) at regular operating conditions. Voltage degradation rates of 20 to 40%/1,000 hours were observed under severe operating conditions, depending on the test...

  17. Optimization of Fuel Cell System Operating Conditions for Fuel Cell Vehicles

    OpenAIRE

    Zhao, Hengbing; Burke, Andy

    2008-01-01

    Proton Exchange Membrane fuel cell (PEMFC) technology for use in fuel cell vehicles and other applications has been intensively developed in recent decades. Besides the fuel cell stack, air and fuel control and thermal and water management are major challenges in the development of the fuel cell for vehicle applications. The air supply system can have a major impact on overall system efficiency. In this paper a fuel cell system model for optimizing system operating conditions was developed wh...

  18. Polymer electrolyte fuel cells physical principles of materials and operation

    CERN Document Server

    Eikerling, Michael

    2014-01-01

    The book provides a systematic and profound account of scientific challenges in fuel cell research. The introductory chapters bring readers up to date on the urgency and implications of the global energy challenge, the prospects of electrochemical energy conversion technologies, and the thermodynamic and electrochemical principles underlying the operation of polymer electrolyte fuel cells. The book then presents the scientific challenges in fuel cell research as a systematic account of distinct components, length scales, physicochemical processes, and scientific disciplines. The main part of t

  19. Zirconium Recycle Test Equipment for Hot Cell Operations

    International Nuclear Information System (INIS)

    Collins, Emory D.; DelCul, Guillermo Daniel; Spencer, Barry B.; Bradley, Eric Craig; Brunson, Ronald Ray

    2015-01-01

    The equipment components and assembly support work were modified for optimized, remote hot cell operations to complete this milestone. The modifications include installation of a charging door, Swagelok connector for the off-gas line between the reactor and condenser, and slide valve installation to permit attachment/replacement of the product salt collector bottle.

  20. Outdoor and indoor sources of residential radiofrequency electromagnetic fields, personal cell phone and cordless phone use, and cognitive function in 5-6 years old children

    NARCIS (Netherlands)

    Guxens, Mònica; Vermeulen, Roel; van Eijsden, Manon; Beekhuizen, Johan; Vrijkotte, Tanja G M; van Strien, Rob T; Kromhout, Hans; Huss, Anke

    2016-01-01

    BACKGROUND: Little is known about the exposure of young children to radiofrequency electromagnetic fields (RF-EMF) and potentially associated health effects. We assessed the relationship between residential RF-EMF exposure from mobile phone base stations, residential presence of indoor sources,

  1. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  2. Cooperative Management for a Cluster of Residential Prosumers

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2016-01-01

    This paper proposes an energy management system for coordinating distributed prosumers. The prosumers are residential microgrids which internally produce and consume energy for autonomous operation. However, better performance is achieved by cooperative operation with other prosumers neighbors. E...

  3. Design, evaluation and recommedation effort relating to the modification of a residential 3-ton absorption cycle cooling unit for operation with solar energy

    Science.gov (United States)

    Merrick, R. H.; Anderson, P. P.

    1973-01-01

    The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.

  4. Stochastic analysis of residential micro combined heat and power system

    DEFF Research Database (Denmark)

    Karami, H.; Sanjari, M. J.; Gooi, H. B.

    2017-01-01

    In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm...... algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected...

  5. Strategies for Lowering Solid Oxide Fuel Cells Operating Temperature

    Directory of Open Access Journals (Sweden)

    Albert Tarancón

    2009-11-01

    Full Text Available Lowering the operating temperature of solid oxide fuel cells (SOFCs to the intermediate range (500–700 ºC has become one of the main SOFC research goals. High operating temperatures put numerous requirements on materials selection and on secondary units, limiting the commercial development of SOFCs. The present review first focuses on the main effects of reducing the operating temperature in terms of materials stability, thermo-mechanical mismatch, thermal management and efficiency. After a brief survey of the state-of-the-art materials for SOFCs, attention is focused on emerging oxide-ionic conductors with high conductivity in the intermediate range of temperatures with an introductory section on materials technology for reducing the electrolyte thickness. Finally, recent advances in cathode materials based on layered mixed ionic-electronic conductors are highlighted because the decreasing temperature converts the cathode into the major source of electrical losses for the whole SOFC system. It is concluded that the introduction of alternative materials that would enable solid oxide fuel cells to operate in the intermediate range of temperatures would have a major impact on the commercialization of fuel cell technology.

  6. Mechanical behaviour of PEM fuel cell catalyst layers during regular cell operation

    OpenAIRE

    Maher A.R. Sadiq Al-Baghdadi

    2010-01-01

    Damage mechanisms in a proton exchange membrane fuel cell are accelerated by mechanical stresses arising during fuel cell assembly (bolt assembling), and the stresses arise during fuel cell running, because it consists of the materials with different thermal expansion and swelling coefficients. Therefore, in order to acquire a complete understanding of the mechanical behaviour of the catalyst layers during regular cell operation, mechanical response under steady-state hygro-thermal stresses s...

  7. Non-Hermitian Operator Modelling of Basic Cancer Cell Dynamics

    Science.gov (United States)

    Bagarello, Fabio; Gargano, Francesco

    2018-04-01

    We propose a dynamical system of tumor cells proliferation based on operatorial methods. The approach we propose is quantum-like: we use ladder and number operators to describe healthy and tumor cells birth and death, and the evolution is ruled by a non-hermitian Hamiltonian which includes, in a non reversible way, the basic biological mechanisms we consider for the system. We show that this approach is rather efficient in describing some processes of the cells. We further add some medical treatment, described by adding a suitable term in the Hamiltonian, which controls and limits the growth of tumor cells, and we propose an optimal approach to stop, and reverse, this growth.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: RESIDENTIAL ELECTRIC POWER GENERATION USING THE PLUG POWER SU1 FUEL CELL SYSTEM

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Plug Power SU1 Fuel Cell System manufactured by Plug Power. The SU1 is a proton exchange membrane fuel cell that requires hydrogen (H2) as fuel. H2 is generally not available, so the ...

  9. Operating Cell Temperature Determination in Flat-Plate Photovoltaic Modules

    International Nuclear Information System (INIS)

    Chenlo, F.

    2002-01-01

    Two procedures (simplified and complete) to determine me operating cell temperature in photovoltaic modules operating in real conditions assuming isothermal stationary modules are presented in this work. Some examples are included that show me dependence of this temperature on several environmental (sky, ground and ambient temperatures, solar irradiance, wind speed, etc.) and structural (module geometry and size, encapsulating materials, anti reflexive optical coatings, etc.) factors and also on electrical module performance. In a further step temperature profiles for non-isothermal modules are analysed besides transitory effects due to variable irradiance and wind gusts. (Author) 27 refs

  10. Characteristics of Subfreezing Operation of Polymer Electrolyte Membrane Fuel Cells

    Science.gov (United States)

    Mishler, Jeffrey Harris

    Polymer Electrolyte Membrane (PEM) Fuel Cells are capable of high efficiency operation, and are free of NOx, SOx, and CO2 emissions when using hydrogen fuel, and ideally suited for use in transportation applications due to their high power density and low operating temperatures. However, under subfreezing conditions which may be encountered during winter seasons in some areas, product water will freeze within the membrane, cathode side catalyst layer and gas diffusion media, leading to voltage loss and operation failure. Experiments were undertaken in order to characterize the amount and location of water during fuel cell operation. First, in-situ neutron radiography was undertaken on the fuel cells at a normal operating temperature for various operating current densities, inlet relative humidities, and diffusion media hydrophobicities. It was found that more hydrophobic cathode microporous layer (MPL) or hydrophilic anode MPL may result in a larger amount of water transporting back to the anode. The water profiles along the channels were measured and the point of liquid water emergence, where two phase flow begins, was compared to previous models. Secondly, under subfreezing temperatures, neutron imaging showed that water ice product accumulates because of lack of a water removal mechanism. Water was observed under both the lands and channels, and increased almost linearly with time. It is found that most ice exists in the cathode side. With evidence from experimental observation, a cold start model was developed and explained, following existing approaches in the literature. Three stages of cold start are explained: membrane saturation, ice storage in catalyst layer pores, and then ice melting. The voltage losses due to temperature change, increased transport resistance, and reduced electrochemical surface area. The ionic conductivity of the membrane at subfreezing temperatures was modeled. Voltage evolution over time for isothermal cold starts was predicted and

  11. In SITU Transmission Electron Microscopy on Operating Electrochemical CELLS

    DEFF Research Database (Denmark)

    Gualandris, Fabrizio; Simonsen, Søren Bredmose; Mogensen, Mogens Bjerg

    2016-01-01

    Solid oxide cells (SOC) have the potential of playing a significant role in the future efficient energy system scenario. In order to become widely commercially available, an improved performance and durability of the cells has to be achieved [1]. Conventional scanning and transmission SEM and TEM...... have been often used for ex-situ post mortem characterization of SOFCs and SOECs [2,3]. However, in order to get fundamental insight of the microstructural development of SOFC/SOEC during operation conditions in situ studies are necessary [4]....

  12. Fuel cell bus operation, system investigation H2 bus

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The WP covers two tasks: - Prepartion of Technical Catalogue: In cooperation with ICIL, AR have compiled a technical catalogue, providing the impartial descriptions, both of existing technology and regulations, and the likely future developments of these, as to remedy the first problem faced by a potential hydrogen bus fleet operator viz the absence of an impartial description of the available vehicle and fuels systems together with the absence of a description of regulatory and safety factors which need consideration. - Fuel Cell Bus Operation - System Investigation H 2 Bus: The application of fuel cell electric generation systems to hybrid electrical buses or electrical busses without any storage system on board is considered. The task will cover safety and environmental aspects, a cost estimate and a market evaluation. (orig.)

  13. In-Situ Transmission Electron Microscopy on Operating Electrochemical Cells

    DEFF Research Database (Denmark)

    Gualandris, Fabrizio; Simonsen, Søren Bredmose; Mogensen, Mogens Bjerg

    have been often used for ex-situpost mortem characterization of SOFCs and SOECs [2,3]. However, in order to get fundamental insight of themicrostructural development of SOFC/SOEC during operation conditions in-situ studies are necessary [4]. Thedevelopment of advanced TEM chips and holders makes...... it possible to undertake analysis during exposure to theSOFC/SOEC sample of reactive gas flow, elevated temperatures and electrical biasing in combination. Thisallows the study of nanostructure development under temperature and electrode polarisation conditions similarto operation conditions.In this work, we...... with animage corrector and a differential pumping system.A symmetric cell was prepared by depositing a cell consisting of three thin films on a strontium titanate (STO)single crystal substrate by pulsed laser deposition (PLD). Lanthanum strontium cobaltite La0.6Sr0.4CoO3-δ (LSC)was chosen as electrode...

  14. Stochastic analysis of residential micro combined heat and power system

    International Nuclear Information System (INIS)

    Karami, H.; Sanjari, M.J.; Gooi, H.B.; Gharehpetian, G.B.; Guerrero, J.M.

    2017-01-01

    Highlights: • Applying colonial competitive algorithm to the problem of optimal dispatching. • Economic modeling of the residential integrated energy system. • Investigating differences of stand-alone and system-connected modes of fuel cell operation. • Considering uncertainty on the electrical load. • The effects of battery capacity and its efficiency on the system is investigated. - Abstract: In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm is adopted to the hybrid energy system scheduling problem and different energy resources are optimally scheduled to have optimal operating cost of hybrid energy system. In order to show the effectiveness of the colonial competitive algorithm, the results are compared with the results of the harmony search algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected to be used effectively in a real hybrid energy system.

  15. Anodes for Solid Oxide Fuel Cells Operating at Low Temperatures

    DEFF Research Database (Denmark)

    Abdul Jabbar, Mohammed Hussain

    An important issue that has limited the potential of Solid Oxide Fuel Cells (SOFCs) for portable applications is its high operating temperatures (800-1000 ºC). Lowering the operating temperature of SOFCs to 400-600 ºC enable a wider material selection, reduced degradation and increased lifetime....... On the other hand, low-temperature operation poses serious challenges to the electrode performance. Effective catalysts, redox stable electrodes with improved microstructures are the prime requisite for the development of efficient SOFC anodes. The performance of Nb-doped SrT iO3 (STN) ceramic anodes...... at 400ºC. The potential of using WO3 ceramic as an alternative anode materials has been explored. The relatively high electrode polarization resistance obtained, 11 Ohm cm2 at 600 ºC, proved the inadequate catalytic activity of this system for hydrogen oxidation. At the end of this thesis...

  16. Life-cycle energy of residential buildings in China

    International Nuclear Information System (INIS)

    Chang, Yuan; Ries, Robert J.; Wang, Yaowu

    2013-01-01

    In the context of rapid urbanization and new construction in rural China, residential building energy consumption has the potential to increase with the expected increase in demand. A process-based hybrid life-cycle assessment model is used to quantify the life-cycle energy use for both urban and rural residential buildings in China and determine the energy use characteristics of each life cycle phase. An input–output model for the pre-use phases is based on 2007 Chinese economic benchmark data. A process-based life-cycle assessment model for estimating the operation and demolition phases uses historical energy-intensity data. Results show that operation energy in both urban and rural residential buildings is dominant and varies from 75% to 86% of life cycle energy respectively. Gaps in living standards as well as differences in building structure and materials result in a life-cycle energy intensity of urban residential buildings that is 20% higher than that of rural residential buildings. The life-cycle energy of urban residential buildings is most sensitive to the reduction of operational energy intensity excluding heating energy which depends on both the occupants' energy-saving behavior as well as the performance of the building itself. -- Highlights: •We developed a hybrid LCA model to quantify the life-cycle energy for urban and rural residential buildings in China. •Operation energy in urban and rural residential buildings is dominant, varying from 75% to 86% of life cycle energy respectively. •Compared with rural residential buildings, the life-cycle energy intensity of urban residential buildings is 20% higher. •The life-cycle energy of urban residential buildings is most sensitive to the reduction of daily activity energy

  17. Novel materials for fuel cells operating on liquid fuels

    Directory of Open Access Journals (Sweden)

    César A. C. Sequeira

    2017-05-01

    Full Text Available Towards commercialization of fuel cell products in the coming years, the fuel cell systems are being redefined by means of lowering costs of basic elements, such as electrolytes and membranes, electrode and catalyst materials, as well as of increasing power density and long-term stability. Among different kinds of fuel cells, low-temperature polymer electrolyte membrane fuel cells (PEMFCs are of major importance, but their problems related to hydrogen storage and distribution are forcing the development of liquid fuels such as methanol, ethanol, sodium borohydride and ammonia. In respect to hydrogen, methanol is cheaper, easier to handle, transport and store, and has a high theoretical energy density. The second most studied liquid fuel is ethanol, but it is necessary to note that the highest theoretically energy conversion efficiency should be reached in a cell operating on sodium borohydride alkaline solution. It is clear that proper solutions need to be developed, by using novel catalysts, namely nanostructured single phase and composite materials, oxidant enrichment technologies and catalytic activity increasing. In this paper these main directions will be considered.

  18. Test results for fuel cell operation on anaerobic digester gas

    Science.gov (United States)

    Spiegel, R. J.; Preston, J. L.

    EPA, in conjunction with ONSI, embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the process of treating sewage anaerobically to reduce solids. ADG is primarily comprised of methane (57-66%), carbon dioxide (33-39%), nitrogen (1-10%), and a small amount of oxygen (sulfur-bearing compounds (principally hydrogen sulfide) and halogen compounds (chlorides). The project has addressed two major issues: development of a cleanup system to remove fuel cell contaminants from the gas and testing/assessing of a modified ONSI PC25 C fuel cell power plant operating on the cleaned, but dilute, ADG. Results to date demonstrate that the ADG fuel cell power plant can, depending on the energy content of the gas, produce electrical output levels close to full power (200 kW) with measured air emissions comparable to those obtained by a natural gas fuel cell. The cleanup system results show that the hydrogen sulfide levels are reduced to below 10 ppbv and halides to approximately 30 ppbv.

  19. Atomistic mechanisms of ReRAM cell operation and reliability

    Science.gov (United States)

    Pandey, Sumeet C.

    2018-01-01

    We present results from first-principles-based modeling that captures functionally important physical phenomena critical to cell materials selection, operation, and reliability for resistance-switching memory technologies. An atomic-scale description of retention, the low- and high-resistance states (RS), and the sources of intrinsic cell-level variability in ReRAM is discussed. Through the results obtained from density functional theory, non-equilibrium Green’s function, molecular dynamics, and kinetic Monte Carlo simulations; the role of variable-charge vacancy defects and metal impurities in determining the RS, the LRS-stability, and electron-conduction in such RS is reported. Although, the statistical electrical characteristics of the oxygen-vacancy (Ox-ReRAM) and conductive-bridging RAM (M-ReRAM) are notably different, the underlying similar electrochemical phenomena describing retention and formation/dissolution of RS are being discussed.

  20. Operating method of molten carbonate type fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tsuneo

    1988-12-06

    Molten carbonate type fuel cell involves a problem of oxidation of anode while the unit is stopped. Although there is a method proposed wherein an inactive gas is supplied to anode during the stoppage, the market-available inactive gas contains a slight amount of oxygen which makes it difficult to prevent the deterioration of the anode. In this invention, at the start and the stop other than the normal operation, a protective gas mixture of an inactive gas with a small amount of hydrogen is supplied to the anode. The inactive gas is a commercial type nitrogen, argon or helium; hydrogen is mixed in amount 0.5 - 2.0% of the inactive gas. By this method, oxygen in air which comes in from the gas-sealed portion of the cell is reduced by hydrogen in the protective gas and is discharged in the form of water. 2 figs.

  1. CFD analysis of laboratory scale phase equilibrium cell operation

    Science.gov (United States)

    Jama, Mohamed Ali; Nikiforow, Kaj; Qureshi, Muhammad Saad; Alopaeus, Ville

    2017-10-01

    For the modeling of multiphase chemical reactors or separation processes, it is essential to predict accurately chemical equilibrium data, such as vapor-liquid or liquid-liquid equilibria [M. Šoóš et al., Chem. Eng. Process.: Process Intensif. 42(4), 273-284 (2003)]. The instruments used in these experiments are typically designed based on previous experiences, and their operation verified based on known equilibria of standard components. However, mass transfer limitations with different chemical systems may be very different, potentially falsifying the measured equilibrium compositions. In this work, computational fluid dynamics is utilized to design and analyze laboratory scale experimental gas-liquid equilibrium cell for the first time to augment the traditional analysis based on plug flow assumption. Two-phase dilutor cell, used for measuring limiting activity coefficients at infinite dilution, is used as a test case for the analysis. The Lagrangian discrete model is used to track each bubble and to study the residence time distribution of the carrier gas bubbles in the dilutor cell. This analysis is necessary to assess whether the gas leaving the cell is in equilibrium with the liquid, as required in traditional analysis of such apparatus. Mass transfer for six different bio-oil compounds is calculated to determine the approach equilibrium concentration. Also, residence times assuming plug flow and ideal mixing are used as reference cases to evaluate the influence of mixing on the approach to equilibrium in the dilutor. Results show that the model can be used to predict the dilutor operating conditions for which each of the studied gas-liquid systems reaches equilibrium.

  2. CFD analysis of laboratory scale phase equilibrium cell operation.

    Science.gov (United States)

    Jama, Mohamed Ali; Nikiforow, Kaj; Qureshi, Muhammad Saad; Alopaeus, Ville

    2017-10-01

    For the modeling of multiphase chemical reactors or separation processes, it is essential to predict accurately chemical equilibrium data, such as vapor-liquid or liquid-liquid equilibria [M. Šoóš et al., Chem. Eng. Process Intensif. 42(4), 273-284 (2003)]. The instruments used in these experiments are typically designed based on previous experiences, and their operation verified based on known equilibria of standard components. However, mass transfer limitations with different chemical systems may be very different, potentially falsifying the measured equilibrium compositions. In this work, computational fluid dynamics is utilized to design and analyze laboratory scale experimental gas-liquid equilibrium cell for the first time to augment the traditional analysis based on plug flow assumption. Two-phase dilutor cell, used for measuring limiting activity coefficients at infinite dilution, is used as a test case for the analysis. The Lagrangian discrete model is used to track each bubble and to study the residence time distribution of the carrier gas bubbles in the dilutor cell. This analysis is necessary to assess whether the gas leaving the cell is in equilibrium with the liquid, as required in traditional analysis of such apparatus. Mass transfer for six different bio-oil compounds is calculated to determine the approach equilibrium concentration. Also, residence times assuming plug flow and ideal mixing are used as reference cases to evaluate the influence of mixing on the approach to equilibrium in the dilutor. Results show that the model can be used to predict the dilutor operating conditions for which each of the studied gas-liquid systems reaches equilibrium.

  3. The ultrastructure of tumor cells in patients with rectal cancer after pre-operative irradiation and intra-operative cryotherapy

    International Nuclear Information System (INIS)

    Vyinnik, Yu.O.; Kotenko, O.Je.; Nevzorov, V.P.; Chyibyisov, L.P.

    2000-01-01

    Electronic microscopy of the tumor cells was performed to confirm the efficacy of combined pre-operative gamma-therapy and intraoperative cryotherapy (CT). Pre-operative irradiation at the dose of 20 Gy accompanied by intra-operative cryotherapy caused the changes in the ultrastructure, the depth and degree of which allow to consider them destructive and irreversible

  4. Family ties and residential locations

    NARCIS (Netherlands)

    Mulder, C.H.; Cooke, T.J.

    2009-01-01

    In this paper, and in the Special Issue it introduces, the focus is on the role of family ties in residential location choice and, conversely, the role of residential locations in maintaining family ties. Not only do events in the nuclear family trigger residential relocations, but nearby family

  5. Cathodes for Solid Oxide Fuel Cells Operating at Low Temperatures

    DEFF Research Database (Denmark)

    Samson, Alfred Junio

    . High performance cathodes were obtained from strontium-doped lanthanum cobaltite (LSC) infiltrated - Ce0.9Gd0.1O1.95 (CGO) ionic conducting backbone. Systematic tuning of the CGO and LSC firing temperatures and LSC loading resulted in a cathode with low polarization resistance, Rp = 0.044 cm2 at 600......This dissertation focuses on the development of nanostructured cathodes for solid oxide fuel cells (SOFCs) and their performance at low operating temperatures. Cathodes were mainly fabricated by the infiltration method, whereby electrocatalysts are introduced onto porous, ionic conducting backbones...... with increasing LSC firing temperature, highlighting the importance of materials compability over higher ionic conductivity. The potential of Ca3Co4O9+delta as an electrocatalyst for SOFCs has also been explored and encouraging results were found i.e., Rp = 0.64 cm2 for a Ca3Co4O9+delta/CGO 50 vol % composite...

  6. GREEN RETROFITTING RESIDENTIAL BUILDINGS

    Science.gov (United States)

    When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...

  7. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  8. Quantum theory of operation for rectenna solar cells

    International Nuclear Information System (INIS)

    Grover, Sachit; Joshi, Saumil; Moddel, Garret

    2013-01-01

    Optical rectennas, sub-micrometre antenna-coupled diodes, can directly rectify solar and thermal electromagnetic radiation, and have been proposed as an alternative to conventional semiconductor photovoltaics. We develop a comprehensive description of the operating principle of rectenna solar cells. In prior work classical concepts from microwave rectenna theory have been applied to the analysis of photovoltaic power generation using these ultra-high frequency rectifiers. Because of their high photon energy the interaction of petahertz frequency waves with fast-responding diodes requires a semiclassical analysis. We use the theory of photon-assisted transport to derive the current–voltage [I(V)] characteristics of metal/insulator/metal tunnel diodes under illumination. We show how power is generated in the second quadrant of the I(V) characteristic, derive solar cell parameters, and analyse the key variables that influence the performance under monochromatic radiation and to a first order approximation. The efficiency improves with reduced dark current under reverse bias and increasing incident electromagnetic power. (paper)

  9. Optimal Design and Operation of A Syngas-fuelled SOFC Micro-CHP System for Residential Applications in Different Climate Zones in China

    DEFF Research Database (Denmark)

    Yang, Wenyuan; Liso, Vincenzo; Zhao, Yingru

    2013-01-01

    heat-to-power load ratio. Therefore, the aim of this study is to investigate the optimal design and operation of a syngas-fuelled SOFC micro-CHP system for small households located in five different climate zones in China. The ability of the micro-CHP to cover the heat and electricity demand of a 70m2...... demand. Numerical simulations are conducted in Matlab environment. System design trade-offs are discussed to determine the optimal match between the energy demand of the household for different climates across China and the energy supply of the micro-CHP during the whole year. Moreover, criteria...

  10. Optimal design and operation of a syngas-fuelled SOFC micro CHP system for residential applications in different climate zones in China

    DEFF Research Database (Denmark)

    Yang, Wenyuan; Zhao, Yingru; Liso, Vincenzo

    2014-01-01

    under difference climate conditions to ensure that it is well matched with the local heat-to-power ratio. The aim of this study is to investigate the optimal design and operation of a syngas-fuelled SOFC micro-CHP system for small households located in five different climate zones in China. The ability...... of the micro-CHP to cover the heat and electricity demand of a 70 m2 single-family apartment with an average number of occupants of 3 is evaluated. A detailed model of the micro-CHP unit coupled with a hot water storage tank and an auxiliary boiler is developed. System design trade-offs are discussed...

  11. Adenosinergic Immunosuppression by Human Mesenchymal Stromal Cells Requires Co-Operation with T cells.

    Science.gov (United States)

    Kerkelä, Erja; Laitinen, Anita; Räbinä, Jarkko; Valkonen, Sami; Takatalo, Maarit; Larjo, Antti; Veijola, Johanna; Lampinen, Milla; Siljander, Pia; Lehenkari, Petri; Alfthan, Kaija; Laitinen, Saara

    2016-03-01

    Mesenchymal stem/stromal cells (MSCs) have the capacity to counteract excessive inflammatory responses. MSCs possess a range of immunomodulatory mechanisms, which can be deployed in response to signals in a particular environment and in concert with other immune cells. One immunosuppressive mechanism, not so well-known in MSCs, is mediated via adenosinergic pathway by ectonucleotidases CD73 and CD39. In this study, we demonstrate that adenosine is actively produced from adenosine 5'-monophosphate (AMP) by CD73 on MSCs and MSC-derived extracellular vesicles (EVs). Our results indicate that although MSCs express CD39 at low level and it colocalizes with CD73 in bulge areas of membranes, the most efficient adenosine production from adenosine 5'-triphosphate (ATP) requires co-operation of MSCs and activated T cells. Highly CD39 expressing activated T cells produce AMP from ATP and MSCs produce adenosine from AMP via CD73 activity. Furthermore, adenosinergic signaling plays a role in suppression of T cell proliferation in vitro. In conclusion, this study shows that adenosinergic signaling is an important immunoregulatory mechanism of MSCs, especially in situations where ATP is present in the extracellular environment, like in tissue injury. An efficient production of immunosuppressive adenosine is dependent on the concerted action of CD39-positive immune cells with CD73-positive cells such as MSCs or their EVs. © 2016 AlphaMed Press.

  12. Guidelines for residential commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-31

    Currently, houses do not perform optimally or even as many codes and forecasts predict, largely because they are field assembled and there is no consistent process to identify problems or to correct them. Residential commissioning is a solution to this problem. This guide is the culmination of a 30-month project that began in September 1999. The ultimate objective of the project is to increase the number of houses that undergo commissioning, which will improve the quality, comfort, and safety of homes for California citizens. The project goal is to lay the groundwork for a residential commissioning industry in California focused on end-use energy and non-energy issues. As such, we intend this guide to be a beginning and not an end. Our intent is that the guide will lead to the programmatic integration of commissioning with other building industry processes, which in turn will provide more value to a single site visit for people such as home energy auditors and raters, home inspectors, and building performance contractors. Project work to support the development of this guide includes: a literature review and annotated bibliography, which facilitates access to 469 documents related to residential commissioning published over the past 20 years (Wray et al. 2000), an analysis of the potential benefits one can realistically expect from commissioning new and existing California houses (Matson et al. 2002), and an assessment of 107 diagnostic tools for evaluating residential commissioning metrics (Wray et al. 2002). In this guide, we describe the issues that non-experts should consider in developing a commissioning program to achieve the benefits we have identified. We do this by providing specific recommendations about: how to structure the commissioning process, which diagnostics to use, and how to use them to commission new and existing houses. Using examples, we also demonstrate the potential benefits of applying the recommended whole-house commissioning approach to

  13. Electrolytes for Wide Operating Temperature Lithium-Ion Cells

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor)

    2016-01-01

    Provided herein are electrolytes for lithium-ion electrochemical cells, electrochemical cells employing the electrolytes, methods of making the electrochemical cells and methods of using the electrochemical cells over a wide temperature range. Included are electrolyte compositions comprising a lithium salt, a cyclic carbonate, a non-cyclic carbonate, and a linear ester and optionally comprising one or more additives.

  14. Solid Oxide Fuel Cell Based Upon Colloidal Deposition of Thin Films for Lower Temperature Operation (Preprint)

    National Research Council Canada - National Science Library

    Reitz, T. L; Xiao, H

    2006-01-01

    In order to reduce the operating temperature of solid oxide fuel cells (SOFCs), anode-supported cells incorporating thin film electrolytes in conjunction with anode/electrolyte and cathode/electrolyte interlayers were studied...

  15. Low stoichiometry operation of a proton exchange membrane fuel cell employing the interdigitated flow field

    DEFF Research Database (Denmark)

    Berning, Torsten; Kær, Søren Knudsen

    2012-01-01

    A multiphase fuel cell model based on computational fluid dynamics is used to investigate the possibility of operating a proton exchange membrane fuel cell at low stoichiometric flow ratios (ξ gases. A case study...

  16. Test results and operational characteristics of prototype SSCL half cell

    International Nuclear Information System (INIS)

    McInturff, A.D.; Burgett, W.; Carter, H.

    1994-01-01

    The SSCL Accelerator System's String Test (ASST) has had several cool down, subsequent operational test series, and warm up cycles. The first cycle of these was rather limited in scope as mandated by Congress. The subsequent tests have been performed to obtain more complete information about parameters of, or operating experience with, the ensemble of magnets and spools when operating serially as in accelerator operations. The tests and procedures performed to date have emphasized cryogenic, mechanical, and electrical operations. These have included running, as well as upset conditions, i.e., superconducting to normal transition of the string (quench). This paper represents a summary of the operational test results and characteristics seen to date. A limited discussion will be included as to their implications with respect to a successful accelerator operation

  17. Re-thinking residential mobility

    Science.gov (United States)

    van Ham, Maarten; Findlay, Allan M.

    2015-01-01

    While researchers are increasingly re-conceptualizing international migration, far less attention has been devoted to re-thinking short-distance residential mobility and immobility. In this paper we harness the life course approach to propose a new conceptual framework for residential mobility research. We contend that residential mobility and immobility should be re-conceptualized as relational practices that link lives through time and space while connecting people to structural conditions. Re-thinking and re-assessing residential mobility by exploiting new developments in longitudinal analysis will allow geographers to understand, critique and address pressing societal challenges. PMID:27330243

  18. Large-Scale Residential Demolition

    Science.gov (United States)

    The EPA provides resources for handling residential demolitions or renovations. This includes planning, handling harmful materials, recycling, funding, compliance assistance, good practices and regulations.

  19. Higher-capacity lithium ion battery chemistries for improved residential energy storage with micro-cogeneration

    International Nuclear Information System (INIS)

    Darcovich, K.; Henquin, E.R.; Kenney, B.; Davidson, I.J.; Saldanha, N.; Beausoleil-Morrison, I.

    2013-01-01

    Highlights: • Characterized two novel high capacity electrode materials for Li-ion batteries. • A numerical discharge model was run to characterize Li-ion cell behavior. • Engineering model of Li-ion battery pack developed from cell fundamentals. • ESP-r model integrated micro-cogeneration and high capacity Li-ion storage. • Higher capacity batteries shown to improve micro-cogeneration systems. - Abstract: Combined heat and power on a residential scale, also known as micro-cogeneration, is currently gaining traction as an energy savings practice. The configuration of micro-cogeneration systems is highly variable, as local climate, energy supply, energy market and the feasibility of including renewable type components such as wind turbines or photovoltaic panels are all factors. Large-scale lithium ion batteries for electrical storage in this context can provide cost savings, operational flexibility, and reduced stress on the distribution grid as well as a degree of contingency for installations relying upon unsteady renewables. Concurrently, significant advances in component materials used to make lithium ion cells offer performance improvements in terms of power output, energy capacity, robustness and longevity, thereby enhancing their prospective utility in residential micro-cogeneration installations. The present study evaluates annual residential energy use for a typical Canadian home connected to the electrical grid, equipped with a micro-cogeneration system consisting of a Stirling engine for supplying heat and power, coupled with a nominal 2 kW/6 kW h lithium ion battery. Two novel battery cathode chemistries, one a new Li–NCA material, the other a high voltage Ni-doped lithium manganate, are compared in the residential micro-cogeneration context with a system equipped with the presently conventional LiMn 2 O 4 spinel-type battery

  20. Trial operation of a phosphoric acid fuel cell (PC25) for CHP applications in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Uhrig, M.; Droste, W.; Wolf, D. [Ruhrgas AG, Dorsten (Germany)

    1996-12-31

    In Europe, ten 200 kW phosphoric acid fuel cells (PAFCs) produced by ONSI (PC25) are currently in operation. Their operators collaborate closely in the European Fuel Cell Users Group (EFCUG). The experience gained from trial operation by the four German operators - HEAG, HGW/HEW, Thyssengas and Ruhrgas - coincides with that of the other European operators. This experience can generally be regarded as favourable. With a view to using fuel cells in combined heat and power generation (CHP), the project described in this report, which was carried out in cooperation with the municipal utility of Bochum and Gasunie of the Netherlands, aimed at gaining experience with the PC 25 in field operation under the specific operating conditions prevailing in Europe. The work packages included heat-controlled operation, examination of plant behavior with varying gas properties and measurement of emissions under dynamic load conditions. The project received EU funding under the JOULE programme.

  1. Performance study of a dual power source residential CCHP system based on PEMFC and PTSC

    International Nuclear Information System (INIS)

    Chen, Xi; Gong, Guangcai; Wan, Zhongmin; Zhang, Caizhi; Tu, Zhengkai

    2016-01-01

    Highlights: • A novel dual power source residential CCHP system model is proposed. • Low temperature and high current density guarantee the high efficiency of PTSC. • High system efficiency can be obtained at a relatively low solar radiation. • Government subsidy is a crucial factor to improve system economic performance. • System environmental performance is discussed by parametric study. - Abstract: This paper presents an innovative, hybrid residential CCHP system based on fuel cell and solar technologies that can provide electric power, heating and cooling. The CCHP system consists of a proton exchange membrane fuel cell (PEMFC) stack, parabolic trough solar collector (PTSC), double-effect absorption chiller and their relevant accessories. The effects of key operating parameters for PEMFC and PTSC systems (e.g.: current density, operating temperature and solar radiation) on the system thermodynamic performance are analyzed and discussed. The results show that the PEMFC operation temperature has a significant influence on the PTSC output performance in a hybrid CCHP system and that the PTSC also plays an important role as a bridge between the PEMFC stack and absorption chiller. The maximum efficiency of a hybrid system can reach 80.5%, which is higher than conventional CCHP systems, due to the high efficiency of PEMFC, PTSC and double-effect absorption chiller. The economic and environmental analysis of CCHP system are also performed, the results indicate the project is practicable, meanwhile, high current density and solar radiation and low operating temperature can improve pollutant emissions reduction of the system.

  2. Residential energy demand in Brazil

    International Nuclear Information System (INIS)

    Arouca, M.; Gomes, F.M.; Rosa, L.P.

    1981-01-01

    The energy demand in Brazilian residential sector is studied, discussing the methodology for analyzing this demand from some ideas suggested, for developing an adequate method to brazilian characteristics. The residential energy consumption of several fuels in Brazil is also presented, including a comparative evaluation with the United States and France. (author)

  3. Cell saver for on-pump coronary operations reduces systemic inflammatory markers: a randomized trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Nielsen, Claus Henrik; Andersen, Lars Willy

    2010-01-01

    This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB).......This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB)....

  4. Low-temperature fuel cells operating with contaminated feedstock

    NARCIS (Netherlands)

    Wingelaar, P.J.H.

    2007-01-01

    This work concerns the analysis and modeling of the dynamic and static behavior of Polymer Electrolyte Membrane Fuel Cells (PEMFC). Three fundamentally different measurement methods are used to determine the static, the large-signal, and the small-signal dynamic behavior of a fuel cell system. By

  5. Application of adaptive neuro-fuzzy inference system techniques and artificial neural networks to predict solid oxide fuel cell performance in residential microgeneration installation

    Energy Technology Data Exchange (ETDEWEB)

    Entchev, Evgueniy; Yang, Libing [Integrated Energy Systems Laboratory, CANMET Energy Technology Centre, 1 Haanel Dr., Ottawa, Ontario (Canada)

    2007-06-30

    This study applies adaptive neuro-fuzzy inference system (ANFIS) techniques and artificial neural network (ANN) to predict solid oxide fuel cell (SOFC) performance while supplying both heat and power to a residence. A microgeneration 5 kW{sub el} SOFC system was installed at the Canadian Centre for Housing Technology (CCHT), integrated with existing mechanical systems and connected in parallel to the grid. SOFC performance data were collected during the winter heating season and used for training of both ANN and ANFIS models. The ANN model was built on back propagation algorithm as for ANFIS model a combination of least squares method and back propagation gradient decent method were developed and applied. Both models were trained with experimental data and used to predict selective SOFC performance parameters such as fuel cell stack current, stack voltage, etc. The study revealed that both ANN and ANFIS models' predictions agreed well with variety of experimental data sets representing steady-state, start-up and shut-down operations of the SOFC system. The initial data set was subjected to detailed sensitivity analysis and statistically insignificant parameters were excluded from the training set. As a result, significant reduction of computational time was achieved without affecting models' accuracy. The study showed that adaptive models can be applied with confidence during the design process and for performance optimization of existing and newly developed solid oxide fuel cell systems. It demonstrated that by using ANN and ANFIS techniques SOFC microgeneration system's performance could be modelled with minimum time demand and with a high degree of accuracy. (author)

  6. The performance of silicon solar cells operated in liquids

    International Nuclear Information System (INIS)

    Wang Yiping; Fang Zhenlei; Zhu Li; Huang Qunwu; Zhang Yan; Zhang Zhiying

    2009-01-01

    Better performance can be achieved when the bare silicon solar cells are immersed into liquids for the enhanced heat removing. In this study, the performance of solar cells immersed in liquids was examined under simulated sunlight. To distinguish the effects of the liquid optic and electric properties on the solar cells, a comparison between immersion of the solar module and the bare solar cells was carried out. It was found that the optic properties of the liquids can cause minor efficiency changes on the solar cells, while the electric properties of the liquids, the molecular polarizable and ions, are responsible for the most of the changes. The bare solar cells immersed in the non-polar silicon oil have the best performance. The accelerated life tests were carried out at 150 deg. C high temperature and under 200 W/m 2 ultraviolet light irradiation, respectively. It was found that the silicon oil has good stability. This study can give support on the cooling of the concentrated photovoltaic systems by immersing the solar cells in the liquids directly

  7. Establishment and operation of a photovoltaic cell test facility

    Energy Technology Data Exchange (ETDEWEB)

    Pearsall, N.M.; Forbes, I.

    1999-07-01

    This report describes the setting up of a test facility at the University of Northumbria. Details of the equipment specification and procurement are given, and the commissioning and initial operation of the facility, and the measurement procedures for I-V characteristics, spectral response measurements, optical scanning and test charges are outlined. The business plan for the test facility is discussed, and operating experience is reviewed in terms of publicity, services provided, and collaboration.

  8. High Efficiency Polymer Solar Cells with Long Operating Lifetimes

    KAUST Repository

    Peters, Craig H.; Sachs-Quintana, I. T.; Kastrop, John P.; Beaupré , Serge; Leclerc, Mario; McGehee, Michael D.

    2011-01-01

    Organic bulk-heterojunction solar cells comprising poly[N-9'-hepta-decanyl- 2,7-carbazole-alt-5,5-(4',7'-di-2-thienyl-2', 1',3'-benzothiadiazole) (PCDTBT) are systematically aged and demonstrate lifetimes approaching seven years, which is the longest reported lifetime for polymer solar cells. An experimental set-up is described that is capable of testing large numbers of solar cells, holding each device at its maximum power point while controlling and monitoring the temperature and light intensity. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Characterising of solid state electrochemical cells under operation

    DEFF Research Database (Denmark)

    Holtappels, Peter

    2014-01-01

    Compared to significant progress in PEMFC especially regarding the utilization of complex fuels such as methanol significant progress has been made by applying spectroscopic / differential IR and spectrometric techniques to working fuel cells, the processes in solid state high temperature...... electrochemical cells are still a "black box". In order to identify local reaction sites, surface coverage and potential/current introduced materials and surface modifications, in situ techniques are needed to gain a better understanding of the elementary and performance limiting steps for these cells...

  10. High Efficiency Polymer Solar Cells with Long Operating Lifetimes

    KAUST Repository

    Peters, Craig H.

    2011-04-20

    Organic bulk-heterojunction solar cells comprising poly[N-9\\'-hepta-decanyl- 2,7-carbazole-alt-5,5-(4\\',7\\'-di-2-thienyl-2\\', 1\\',3\\'-benzothiadiazole) (PCDTBT) are systematically aged and demonstrate lifetimes approaching seven years, which is the longest reported lifetime for polymer solar cells. An experimental set-up is described that is capable of testing large numbers of solar cells, holding each device at its maximum power point while controlling and monitoring the temperature and light intensity. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Low-noise Collision Operators for Particle-in-cell Simulations

    International Nuclear Information System (INIS)

    Lewandowski, J.L.V.

    2005-01-01

    A new method to implement low-noise collision operators in particle-in-cell simulations is presented. The method is based on the fact that relevant collision operators can be included naturally in the Lagrangian formulation that exemplifies the particle-in-cell simulation method. Numerical simulations show that the momentum and energy conservation properties of the simulated plasma associated with the low-noise collision operator are improved as compared with standard collision algorithms based on random numbers

  12. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  13. Cell Phone Calls in the Operating Theater and Staff Distractions: An Observational Study.

    Science.gov (United States)

    Avidan, Alexander; Yacobi, Galel; Weissman, Charles; Levin, Phillip D

    2017-01-09

    Cell phones are the primary communication tool in our institution. There are no restrictions on their use in the operating rooms. The goal of this study was to evaluate the extent of cell phone use in the operating rooms during elective surgery and to evaluate whether they cause staff distractions. The following data on cell phone use were recorded anonymously: number of incoming and outgoing cell phone calls, duration of cell phone calls and their content (patient related, work related, private), who was distracted by the cell phone calls, and duration of distractions. We made observations during 52 surgeries. There were 205 cell phone calls, 197 (96.1%; median, 3 per surgery; interquartile range, 2-5) incoming and 8 (3.9%) outgoing. Incoming calls were answered on 110 (55.8%) of 197 (median, 2; interquartile range, 1-3) occasions. The mean duration of incoming calls (64 ± 40 seconds) was shorter than those of the outgoing calls (137 ± 242 seconds, P cell phone calls in the operating rooms during elective surgery was lower than expected and caused short-lived distractions mainly to the operating surgeons. We recommend that operating surgeons turn off their cell phones before surgery.

  14. Solid Oxide Fuel Cells Operating on Alternative and Renewable Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaoxing; Quan, Wenying; Xiao, Jing; Peduzzi, Emanuela; Fujii, Mamoru; Sun, Funxia; Shalaby, Cigdem; Li, Yan; Xie, Chao; Ma, Xiaoliang; Johnson, David; Lee, Jeong; Fedkin, Mark; LaBarbera, Mark; Das, Debanjan; Thompson, David; Lvov, Serguei; Song, Chunshan

    2014-09-30

    This DOE project at the Pennsylvania State University (Penn State) initially involved Siemens Energy, Inc. to (1) develop new fuel processing approaches for using selected alternative and renewable fuels – anaerobic digester gas (ADG) and commercial diesel fuel (with 15 ppm sulfur) – in solid oxide fuel cell (SOFC) power generation systems; and (2) conduct integrated fuel processor – SOFC system tests to evaluate the performance of the fuel processors and overall systems. Siemens Energy Inc. was to provide SOFC system to Penn State for testing. The Siemens work was carried out at Siemens Energy Inc. in Pittsburgh, PA. The unexpected restructuring in Siemens organization, however, led to the elimination of the Siemens Stationary Fuel Cell Division within the company. Unfortunately, this led to the Siemens subcontract with Penn State ending on September 23rd, 2010. SOFC system was never delivered to Penn State. With the assistance of NETL project manager, the Penn State team has since developed a collaborative research with Delphi as the new subcontractor and this work involved the testing of a stack of planar solid oxide fuel cells from Delphi.

  15. Sharing your urban residential WiFi (UR-WiFi)

    NARCIS (Netherlands)

    Kawade, Santosh; van Bloem, J.W.H.; Abhayawardhana, V.S.; Wisely, D.

    2006-01-01

    Cheap and ubiquitous broadband wireless access is what most of the operators are aiming for. This paper analyses an innovative proposal to extend the traditional fixed coverage offered by residential broadband into an urban wireless coverage using urban residential wireless fidelity (UR-WiFi)

  16. Safety standards, legislation and codes of practice for fuel cell manufacture and operation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, C.P.

    1999-07-01

    This report examines safety standards, legislation and codes of practice for fuel cell manufacture and operation in the UK, Europe and internationally. Management of health and safety in the UK is discussed, and the characteristics of phosphoric acid (PAFC), proton exchange membrane (PEM), molten carbonate (MCFC), solid oxide (SOFC) fuel cells are described. Fuel cell power plant standards and manufacture in the UK, design and operational considerations, end of life disposal, automotive fuel cell system, and fuelling and vehicular concerns are explored, and standards, legislation and codes of practice are explained in the appendix.

  17. ENERGY STAR Certified Residential Dishwashers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 6.0 ENERGY STAR Program Requirements for Residential Dishwashers that are effective as of...

  18. ENERGY STAR Certified Residential Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are...

  19. ENERGY STAR Certified Residential Refrigerators

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are...

  20. Modeling and operation optimization of a proton exchange membrane fuel cell system for maximum efficiency

    International Nuclear Information System (INIS)

    Han, In-Su; Park, Sang-Kyun; Chung, Chang-Bock

    2016-01-01

    Highlights: • A proton exchange membrane fuel cell system is operationally optimized. • A constrained optimization problem is formulated to maximize fuel cell efficiency. • Empirical and semi-empirical models for most system components are developed. • Sensitivity analysis is performed to elucidate the effects of major operating variables. • The optimization results are verified by comparison with actual operation data. - Abstract: This paper presents an operation optimization method and demonstrates its application to a proton exchange membrane fuel cell system. A constrained optimization problem was formulated to maximize the efficiency of a fuel cell system by incorporating practical models derived from actual operations of the system. Empirical and semi-empirical models for most of the system components were developed based on artificial neural networks and semi-empirical equations. Prior to system optimizations, the developed models were validated by comparing simulation results with the measured ones. Moreover, sensitivity analyses were performed to elucidate the effects of major operating variables on the system efficiency under practical operating constraints. Then, the optimal operating conditions were sought at various system power loads. The optimization results revealed that the efficiency gaps between the worst and best operation conditions of the system could reach 1.2–5.5% depending on the power output range. To verify the optimization results, the optimal operating conditions were applied to the fuel cell system, and the measured results were compared with the expected optimal values. The discrepancies between the measured and expected values were found to be trivial, indicating that the proposed operation optimization method was quite successful for a substantial increase in the efficiency of the fuel cell system.

  1. Allograft cytotoxicity co-operation between alloimmune T cells and macrophages

    International Nuclear Information System (INIS)

    Jones, B.; Jones, T.C.

    1978-01-01

    T cells from the spleens of C57BL 10 (H-2sup(b)) mice 7 to 12 days after immunization with P815Y (H-2sup(d)) mastocytoma cells have been shown to co-operate synergistically with an adherent component of non-immune starch induced peritoneal cells in the cytostasis of target cells. Although significant values for synergy could be obtained using the ( 125 I) UdR incorporation assay to measure cytostasis, normal peritoneal cells were incapable of co-operating with T cells in cytolysis as measured by 51 Cr release from pre-labelled target cells. Initially, the synergistic interaction was immunologically specific, but non-specific activity could be induced by challenge with specific antigen. (author)

  2. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    This study combines principles of energy systems engineering and statistics to develop integrated models of residential energy use in the United States, to include residential recharging of electric vehicles. These models can be used by government, policymakers, and the utility industry to provide answers and guidance regarding the future of the U.S. energy system. Currently, electric power generation must match the total demand at each instant, following seasonal patterns and instantaneous fluctuations. Thus, one of the biggest drivers of costs and capacity requirement is the electricity demand that occurs during peak periods. These peak periods require utility companies to maintain operational capacity that often is underutilized, outdated, expensive, and inefficient. In light of this, flattening the demand curve has long been recognized as an effective way of cutting the cost of producing electricity and increasing overall efficiency. The problem is exacerbated by expected widespread adoption of non-dispatchable renewable power generation. The intermittent nature of renewable resources and their non-dispatchability substantially limit the ability of electric power generation of adapting to the fluctuating demand. Smart grid technologies and demand response programs are proposed as a technical solution to make the electric power demand more flexible and able to adapt to power generation. Residential demand response programs offer different incentives and benefits to consumers in response to their flexibility in the timing of their electricity consumption. Understanding interactions between new and existing energy technologies, and policy impacts therein, is key to driving sustainable energy use and economic growth. Comprehensive and accurate models of the next-generation power system allow for understanding the effects of new energy technologies on the power system infrastructure, and can be used to guide policy, technology, and economic decisions. This

  3. A Stem Cell-rescue Operation in a Nuclear Devastation

    Directory of Open Access Journals (Sweden)

    Editorial

    2011-01-01

    Full Text Available Dear friends, The aftermath of one of the most devastating post earthquake- tsunamis in the history of mankind, the March 2011 post-earthquake-tsunami-hitnuclear accident in Fukushima, Japan, has brought to fore several questions throughout the world on the safety of nuclearinstallations. Such Calamities,which are far beyond our comprehension, has left all nations with such installations and those planning to expand their nuclear power plant programmes in a dilemma. However, the recent news that the Japanese authorities are considering to harvest and store bone marrow stem cells for transfusion to radiation-exposed workers has ushered in a new ray of hope. The hematopoietic stem cells will be harvested before exposure and in case of bone marrow depletion after radiation exposure; these cells can be immediately retrieved from storage and transfused to the radiation-exposed worker so that they have the potential to re-constitute the entire bone marrow in the patient. This will be a great life-saver and game-changer as bone marrow depletion is one of the major consequences of high levels of radiation exposure. This strategy can be prescribed as a routine procedure in all the countries with such nuclear installations, especially for workers at very high risk of radiation exposure. In future, such preventive strategies should be considered for implementation to not only the workers in the facility, but also the rescue team and the vulnerable population in the radiation zone.The regenerative potential of hematopoietic stem cell (HSC is the key factor to be considered now. This is high time that the studies on optimal in vitro expansion of HSCs and ways of successful engraftment of the transfused cells to a niche of radiation-exposed host environment should be attempted in all earnestness by the regenerative medicine community at present. Natural calamities like this help man to realise that the millions of scientific discoveries and inventions can

  4. Heating great residential units with combustion-motor heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Vossen, W

    1982-10-01

    Economic usage of combustion-motor heat pumps requires: reliable technology and delivery of the heat pump; design and operation. The heat pump must be integrated perfectly into the heating system. This contributions is based on a three-year operational experience with over 150 heat pumps used mainly in residential and administrative buildings (plus commercial buildings, swimming pools, sport centres etc.). These are heat pumps operating on the compression principle with natural gas, liquid gas, or fuel oil.

  5. Environmental and ventilation benefits for underground mining operations using fuel cell powered production equipment

    International Nuclear Information System (INIS)

    Kocsis, C.; Hardcastle, S.

    2007-01-01

    The benefits of replacing diesel engines with fuel cells in mine production equipment were discussed. The paper was part of a multi-year feasibility study conducted to evaluate the use of hydrogen fuel cell-powered equipment to replace diesel engine powered equipment in underground mining operations. The feasibility study demonstrated that fuel cells are capable of eliminating the unwanted by-products of combustion engines. However, the use of fuel cells also reduced the amount of ventilation that mines needed to supply, thereby further reducing energy consumption. This study examined the benefits of replacing diesel engines with fuel cells, and discussed the mitigating qualifiers that may limit ventilation energy savings. Solutions to retaining and maintaining additional ventilation in the event of hydrogen leaks from fuel cell stacks were also investigated. The analyses were conducted on 6 operating mines. Current operating costs were compared with future operating conditions using fuel cell powered production vehicles. Operating costs of the primary ventilation system were established with a mine ventilation simulator. The analysis considered exhaust shaft velocities, heating system air velocities, and levels of silica exposure. Canadian mine design criteria were reviewed. It was concluded that appropriate safeguards are needed along hydrogen distribution lines to lower the impacts of hydrogen leaks. Large financial commitments may also be required to ensure a spark-free environment. 20 refs., 6 tabs., 3 figs

  6. Basic principles of STT-MRAM cell operation in memory arrays

    International Nuclear Information System (INIS)

    Khvalkovskiy, A V; Apalkov, D; Watts, S; Chepulskii, R; Beach, R S; Ong, A; Tang, X; Driskill-Smith, A; Lottis, D; Chen, E; Nikitin, V; Krounbi, M; Butler, W H; Visscher, P B

    2013-01-01

    For reliable operation, individual cells of an STT-MRAM memory array must meet specific requirements on their performance. In this work we review some of these requirements and discuss the fundamental physical principles of STT-MRAM operation, covering the range from device level to chip array performance, and methodology for its development. (paper)

  7. Comparison of photovoltaic cell temperatures in modules operating with exposed and enclosed back surfaces

    Science.gov (United States)

    Namkoong, D.; Simon, F. F.

    1981-01-01

    Four different photovoltaic module designs were tested to determine the cell temperature of each design. The cell temperatures were compared to those obtained on identical design, using the same nominal operating cell temperature (NOCT) concept. The results showed that the NOCT procedure does not apply to the enclosed configurations due to continuous transient conditions. The enclosed modules had higher cell temperatures than the open modules, and insulated modules higher than the uninsulated. The severest performance loss - when translated from cell temperatures - 17.5 % for one enclosed, insulated module as a compared to that module mounted openly.

  8. Is post-operative radiation for renal cell carcinoma justified?

    International Nuclear Information System (INIS)

    Aref, Ibrahim; Bociek, R. Gregory; Salhani, Douglas

    1997-01-01

    Purpose: To identify the pattern of failure in patients with resected renal cell carcinoma (RCC). Materials and methods: The records of 116 patients with unilateral, non-hematogenous metastatic RCC who were treated with definitive surgery and referred to the Ottawa Regional Cancer Centre between 1977 and 1988 were reviewed. Distribution by stage included T1 (3 patients), T2 (42 patients) and T3 (71 patients). The median follow-up was 44 months, with a range of 4-267 months. Results: Local regional failure (LRF) developed in 8 patients. Nine patients developed local or regional recurrence, plus distant failure. Fifty-eight patients had distant metastases (DM) only. The 7-year actuarial rate for LRF and DM were 12%, and 67%, respectively. The overall 7-year actuarial survival rate was 35%, and cause-specific survival was 42%. Conclusions: LRF alone is rare following nephrectomy. DM is the main pattern of failure. This data does not support the role of adjuvant radiation therapy in this disease

  9. Financing Non-Residential Photovoltaic Projects: Options and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Bolinger, Mark

    2009-01-09

    .ii Specifically, due to financial innovation, non-residential entities interested in PV no longer face prohibitively high up-front costs, no longer need to be able to absorb Tax Benefits in order to make the economics pencil out, no longer need to be able to operate and maintain the system, and no longer need to accept the risk that the system does not perform as expected.

  10. Performance Analysis of Air Breathing Proton Exchange Membrane Fuel Cell Stack (PEMFCS) At Different Operating Condition

    Science.gov (United States)

    Sunil, V.; Venkata siva, G.; Yoganjaneyulu, G.; Ravikumar, V. V.

    2017-08-01

    The answer for an emission free power source in future is in the form of fuel cells which combine hydrogen and oxygen producing electricity and a harmless by product-water. A proton exchange membrane (PEM) fuel cell is ideal for automotive applications. A single cell cannot supply the essential power for any application. Hence PEM fuel cell stacks are used. The effect of different operating parameters namely: type of convection, type of draught, hydrogen flow rate, hydrogen inlet pressure, ambient temperature and humidity, hydrogen humidity, cell orientation on the performance of air breathing PEM fuel cell stack was analyzed using a computerized fuel cell test station. Then, the fuel cell stack was subjected to different load conditions. It was found that the stack performs very poorly at full capacity (runs only for 30 min. but runs for 3 hours at 50% capacity). Hence, a detailed study was undertaken to maximize the duration of the stack’s performance at peak load.

  11. Some aspects of traffic safety in residential areas.

    NARCIS (Netherlands)

    Kraay, J.H. & Wegman, F.C.M.

    1977-01-01

    In the framework of international co-operation within OECD Research Group Traffic Safety in Residential areas the Netherlands have accepted the task of collecting Dutch data for a report. As far as Dutch research exists for the various chapters and sections of the complete report, this can be found

  12. Microstructure characterisation of solid oxide electrolysis cells operated at high current density

    DEFF Research Database (Denmark)

    Bowen, Jacob R.; Bentzen, Janet Jonna; Chen, Ming

    degradation of cell components in relation to the loss of electrochemical performance specific to the mode of operation. Thus descriptive microstructure characterization methods are required in combination with electrochemical characterization methods to decipher degradation mechanisms. In the present work......High temperature solid oxide cells can be operated either as fuel cells or electrolysis cells for efficient power generation or production of hydrogen from steam or synthesis gas (H2 + CO) from steam and CO2 respectively. When operated under harsh conditions, they often exhibit microstructural...... quantified using the mean linear intercept method as a function of current density and correlated to increases in serial resistance. The above structural changes are then compared in terms of electrode degradation observed during the co-electrolysis of steam and CO2 at current densities up to -1.5 A cm-2...

  13. Numerical investigation of the effect of operating parameters on a planar solid oxide fuel cell

    International Nuclear Information System (INIS)

    Raj, Abhishek; Sasmito, Agus P.; Shamim, Tariq

    2015-01-01

    Highlights: • Effects of operating parameters on a planar type of SOFC are investigated. • The studies carried out by developing a three dimensional mathematical model. • The cell performance is enhanced at high temperatures and cathode stoichiometry. • Cathode stoichiometry has a high influence on the cell performance. • The effect of anode stoichiometry on the cell performance is low. - Abstract: The three operating parameters – temperature, stoichiometry and the degree of humidification – constitute key factors required to ensure high performance of the solid oxide fuel cell (SOFC). A careful trade-off between performance and parasitic loads is required in order to optimize the output. The present study numerically analyzes the influence of the key operating parameters on the performance of planar type of SOFC and parasitic loads utilizing a validated three dimensional mathematical model which takes into account of the conservation of mass, momentum, species and charge. The numerical results indicate that the cell performance is enhanced at high temperatures and cathode stoichiometry and it declines with increasing cathode relative humidity. Furthermore, cathode stoichiometry is found to have higher influence on the cell performance as compared to the anode stoichiometry. The gain in cell performance however, has to be balanced with the changing parasitic load requirement from pumping, humidification and heating. The results presented herein can assist in the selection of optimum or near-to-optimum operating parameters for high performance planar type SOFC

  14. Optimal Resources Planning of Residential Complex Energy System in a Day-ahead Market Based on Invasive Weed Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    P. Αhmadi

    2017-10-01

    Full Text Available This paper deals with optimal resources planning in a residential complex energy system, including FC (fuel cell, PV (Photovoltaic panels and the battery. A day-ahead energy management system (EMS based on invasive weed optimization (IWO algorithm is defined for managing different resources to determine an optimal operation schedule for the energy resources at each time interval to minimize the operation cost of a smart residential complex energy system. Moreover, in this paper the impacts of the sell to grid and purchase from grid are also considered. All practical constraints of the each energy resources and utility policies are taken into account. Moreover, sensitivity analysis are conducted on electricity prices and sell to grid factor (SGF, in order to improve understanding the impact of key parameters on residential CHP systems economy. It is shown that proposed system can meet all electrical and thermal demands with economic point of view. Also enhancement of electricity price leads to substantial growth in utilization of proposed CHP system.

  15. Online management genetic algorithms of microgrid for residential application

    International Nuclear Information System (INIS)

    Mohamed, Faisal A.; Koivo, Heikki N.

    2012-01-01

    Highlights: ► We determine the optimal Generation optimization scheme of Microgrid. ► We employ Genetic Algorithm to the environmental/economic problem of the MG. ► We captured the optimal behavior of the MG with high accuracy even with new six different cases. - Abstract: This paper proposes a generalized formulation to determine the optimal operating strategy and cost optimization scheme for a MicroGrid (MG) for residential application. Genetic Algorithm is applied to the environmental/economic problem of the MG. The proposed problem is formulated as a nonlinear constrained MO optimization problem. Prior to the optimization of the microgrid itself, models for the system components are determined using real data. The proposed cost function takes into consideration the costs of the emissions, NOx, SO 2 , and CO 2 , start up costs, as well as the operation and maintenance costs. The MG considered in this paper consists of a wind turbine, a microturbine, a diesel generator, a photovoltaic array, a fuel cell, and a battery storage. The optimization is aimed at minimizing the cost function of the system while constraining it to meet the costumer demand and safety of the system. We also add a daily income and outgo from sale or purchased power. The results demonstrate the efficiency of the proposed approach to satisfy the load and to reduce the cost and the emissions. The comparison with other techniques demonstrates the superiority of the proposed approach and confirms its potential to solve the problem.

  16. A comparison of low-pressure and supercharged operation of polymer electrolyte membrane fuel cell systems for aircraft applications

    Science.gov (United States)

    Werner, C.; Preiß, G.; Gores, F.; Griebenow, M.; Heitmann, S.

    2016-08-01

    Multifunctional fuel cell systems are competitive solutions aboard future generations of civil aircraft concerning energy consumption, environmental issues, and safety reasons. The present study compares low-pressure and supercharged operation of polymer electrolyte membrane fuel cells with respect to performance and efficiency criteria. This is motivated by the challenge of pressure-dependent fuel cell operation aboard aircraft with cabin pressure varying with operating altitude. Experimental investigations of low-pressure fuel cell operation use model-based design of experiments and are complemented by numerical investigations concerning supercharged fuel cell operation. It is demonstrated that a low-pressure operation is feasible with the fuel cell device under test, but that its range of stable operation changes between both operating modes. Including an external compressor, it can be shown that the power demand for supercharging the fuel cell is about the same as the loss in power output of the fuel cell due to low-pressure operation. Furthermore, the supercharged fuel cell operation appears to be more sensitive with respect to variations in the considered independent operating parameters load requirement, cathode stoichiometric ratio, and cooling temperature. The results indicate that a pressure-dependent self-humidification control might be able to exploit the potential of low-pressure fuel cell operation for aircraft applications to the best advantage.

  17. Current density distribution mapping in PEM fuel cells as an instrument for operational measurements

    Energy Technology Data Exchange (ETDEWEB)

    Geske, M.; Heuer, M.; Heideck, G.; Styczynski, Z. A. [Otto-von-Guericke University Magdeburg, Chair Electric Power Networks and Renewable Energy Sources, Magdeburg (Germany)

    2010-07-01

    A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC). Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes. (author)

  18. Current Density Distribution Mapping in PEM Fuel Cells as An Instrument for Operational Measurements

    Directory of Open Access Journals (Sweden)

    Martin Geske

    2010-04-01

    Full Text Available A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC. Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes.

  19. Day-ahead residential load forecasting with artificial neural network using smart meter data

    NARCIS (Netherlands)

    Asare-Bediako, B.; Kling, W.L.; Ribeiro, P.F.

    2013-01-01

    Load forecasting is an important operational procedure for the electric industry particularly in a liberalized, deregulated environment. It enables the prediction of utilization of assets, provides input for load/supply balancing and supports optimal energy utilization. Current residential load

  20. Design and Operation of an Electrochemical Methanol Concentration Sensor for Direct Methanol Fuel Cell Systems

    Science.gov (United States)

    Narayanan, S. R.; Valdez, T. I.; Chun, W.

    2000-01-01

    The development of a 150-Watt packaged power source based on liquid feed direct methanol fuel cells is being pursued currently at the Jet propulsion Laboratory for defense applications. In our studies we find that the concentration of methanol in the fuel circulation loop affects the electrical performance and efficiency the direct methanol fuel cell systems significantly. The practical operation of direct methanol fuel cell systems, therefore, requires accurate monitoring and control of methanol concentration. The present paper reports on the principle and demonstration of an in-house developed electrochemical sensor suitable for direct methanol fuel cell systems.

  1. Dynamic modeling and evaluation of solid oxide fuel cell - combined heat and power system operating strategies

    Science.gov (United States)

    Nanaeda, Kimihiro; Mueller, Fabian; Brouwer, Jacob; Samuelsen, Scott

    Operating strategies of solid oxide fuel cell (SOFC) combined heat and power (CHP) systems are developed and evaluated from a utility, and end-user perspective using a fully integrated SOFC-CHP system dynamic model that resolves the physical states, thermal integration and overall efficiency of the system. The model can be modified for any SOFC-CHP system, but the present analysis is applied to a hotel in southern California based on measured electric and heating loads. Analysis indicates that combined heat and power systems can be operated to benefit both the end-users and the utility, providing more efficient electric generation as well as grid ancillary services, namely dispatchable urban power. Design and operating strategies considered in the paper include optimal sizing of the fuel cell, thermal energy storage to dispatch heat, and operating the fuel cell to provide flexible grid power. Analysis results indicate that with a 13.1% average increase in price-of-electricity (POE), the system can provide the grid with a 50% operating range of dispatchable urban power at an overall thermal efficiency of 80%. This grid-support operating mode increases the operational flexibility of the SOFC-CHP system, which may make the technology an important utility asset for accommodating the increased penetration of intermittent renewable power.

  2. Performance of diagonal control structures at different operating conditions for polymer electrolyte membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Serra, Maria; Husar, Attila; Feroldi, Diego; Riera, Jordi [Institut de Robotica i Informatica Industrial, Universitat Politecnica de Catalunya, Consejo Superior de Investigaciones Cientificas, C. Llorens i Artigas 4, 08028 Barcelona (Spain)

    2006-08-25

    This work is focused on the selection of operating conditions in polymer electrolyte membrane fuel cells. It analyses efficiency and controllability aspects, which change from one operating point to another. Specifically, several operating points that deliver the same amount of net power are compared, and the comparison is done at different net power levels. The study is based on a complex non-linear model, which has been linearised at the selected operating points. Different linear analysis tools are applied to the linear models and results show important controllability differences between operating points. The performance of diagonal control structures with PI controllers at different operating points is also studied. A method for the tuning of the controllers is proposed and applied. The behaviour of the controlled system is simulated with the non-linear model. Conclusions indicate a possible trade-off between controllability and optimisation of hydrogen consumption. (author)

  3. Indigenous development of system integration for proton exchange membrane fuel cell operation

    International Nuclear Information System (INIS)

    Hussain, S.; Arshad, M.; Anjum, A.R.

    2011-01-01

    System integration was developed for fuel cell to control various parameters including voltage, current, power, temperature, pressure of gas (H/sub 2/), humidification, etc. The compact software has also been developed for monitoring different parameters of fuel cell system. System integrated was installed on fuel cell stack to manipulate these parameters. The compact software has been linked with the integrated system for visual monitoring of different parameters of fuel cell system during operation on PC. The installation of software and integrated system on fuel cell stack is the key achievement for the safe operation of fuel cell stack and for the provision of requisite power to any electric device for optimum performance. The compact software was developed for micro controller in KIEL. Control card and driver card are controlled by software-driven micro controller. A communication protocol was designed and developed. PC software has been developed to control and watch the values of all parameters of fuel cell such as voltage, current, power, temperature, pressure of hydrogen, pressure of oxygen, operational times and performance of the system on computer screen. (author)

  4. Sinusoidal potential cycling operation of a direct ethanol fuel cell to improving carbon dioxide yields

    Science.gov (United States)

    Majidi, Pasha; Pickup, Peter G.

    2014-12-01

    A direct ethanol fuel cell has been operated under sinusoidal (AC) potential cycling conditions in order to increase the yield of carbon dioxide and thereby increase cell efficiency relative to operation at a fixed potential. At 80 °C, faradaic yields of CO2 as high as 25% have been achieved with a PtRu anode catalyst, while the maximum CO2 production at constant potential was 13%. The increased yields under cycling conditions have been attributed to periodic oxidative stripping of adsorbed CO. These results will be important in the optimization of operating conditions for direct ethanol fuel cells, where the benefits of potential cycling are projected to increase as catalysts that produce CO2 more efficiently are implemented.

  5. Operation strategy for solid oxide fuel cell systems for small-scale stationary applications

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2009-01-01

    Solid oxide fuel cell micro cogeneration systems have the potential to reduce domestic energy consumption by providing both heat and power on site without transmission losses. The high grade heat produced during the operation of the power causes high thermal transients during startup/shutdown pha......Solid oxide fuel cell micro cogeneration systems have the potential to reduce domestic energy consumption by providing both heat and power on site without transmission losses. The high grade heat produced during the operation of the power causes high thermal transients during startup....../shutdown phases and degrades the fuel cells. To counteract the degradation, the system has not to be stressed with rapid load variation during the operation. The analysis will consider an average profile for heat and power demand of a family house. Finally data analysis and power system limitations will be used...

  6. EMISSIONS CHARACTERISTICS OF A RESIDENTIAL PELLET BOILER AND A STOVE

    OpenAIRE

    Win, Kaung Myat; Persson, Tomas

    2010-01-01

    Gaseous and particulate emissions from a residential pellet boiler and a stove are measured at a realistic 6-day operation sequence and during steady state operation. The aim is to characterize the emissions during each phase in order to identify when the major part of the emissions occur to enable actions for emission reduction where the savings can be highest. The characterized emissions comprised carbon monoxide (CO), nitrogen oxide (NO), total organic carbon (TOC) and particulate matter (...

  7. Micro-generation dispatch in a smart residential multi-carrier energy system considering demand forecast error

    International Nuclear Information System (INIS)

    Sanjari, M.J.; Karami, H.; Gooi, H.B.

    2016-01-01

    Highlights: • Combination of day-ahead and hour-ahead optimizations to design online controller. • Investigating the effect of load forecast error on the system operating cost. • Proposing effective method for hour-ahead resource re-dispatch. • Using the HSS algorithm as a powerful and effective optimization method. • Combining long-term and short-term strategies for optimal dispatch of resources. - Abstract: This paper deals with a residential hybrid thermal/electrical grid-connected home energy system incorporating real data for the load demand. A day-ahead scheduling (DAS) algorithm for dispatching different resources has been developed in previous studies to determine the optimal operation scheduling for the distributed energy resources at each time interval so that the operational cost of a smart house is minimized. However, demand of houses may be changed in each hour and cannot be exactly predicted one day ahead. System complexity caused by nonlinear dynamics of the fuel cell, as a combined heat and power device, and battery charging and discharging time make it difficult to find the optimal operating point of the system by using the optimization algorithms quickly in online applications. In this paper, the demand forecast error is studied and a near-optimal dispatch strategy by using artificial neural network (ANN) is proposed for the residential energy system when the demand changes are known one hour ahead with respect to the predicted day-ahead values. The day-ahead and hour-ahead optimizations are combined and ANN training inputs are adjusted according to the problem such that the economic dispatch of different energy resources can be achieved by the proposed method compared with previous studies. Using the model of the fuel cell extracted from experimental measurement and real data for the load demand makes the results more applicable in real residential energy systems.

  8. Frequency Based Real-time Pricing for Residential Prosumers

    Science.gov (United States)

    Hambridge, Sarah Mabel

    This work is the first to explore frequency based pricing for secondary frequency control as a price-reactive control mechanism for residential prosumers. A frequency based real-time electricity rate is designed as an autonomous market control mechanism for residential prosumers to provide frequency support as an ancillary service. In addition, prosumers are empowered to participate in dynamic energy transactions, therefore integrating Distributed Energy Resources (DERs), and increasing distributed energy storage onto the distributed grid. As the grid transitions towards DERs, a new market based control system will take the place of the legacy distributed system and possibly the legacy bulk power system. DERs provide many benefits such as energy independence, clean generation, efficiency, and reliability to prosumers during blackouts. However, the variable nature of renewable energy and current lack of installed energy storage on the grid will create imbalances in supply and demand as uptake increases, affecting the grid frequency and system operation. Through a frequency-based electricity rate, prosumers will be encouraged to purchase energy storage systems (ESS) to offset their neighbor's distributed generation (DG) such as solar. Chapter 1 explains the deregulation of the power system and move towards Distributed System Operators (DSOs), as prosumers become owners of microgrids and energy cells connected to the distributed system. Dynamic pricing has been proposed as a benefit to prosumers, giving them the ability to make decisions in the energy market, while also providing a way to influence and control their behavior. Frequency based real-time pricing is a type of dynamic pricing which falls between price-reactive control and transactive control. Prosumer-to-prosumer transactions may take the place of prosumer-to-utility transactions, building The Energy Internet. Frequency based pricing could be a mechanism for determining prosumer prices and supporting

  9. Understanding Residential Polarization in a Globalizing City

    Directory of Open Access Journals (Sweden)

    Ibrahim Rotimi Aliu

    2013-12-01

    Full Text Available This study examines the spatial polarization that characterizes the dwellings in the African leading megacity of Lagos. Data were collected through an extensive housing survey carried out on 1,485 household residences in 56 wards within 12 administrative units in Lagos megacity. The spatial dimension of residential density in the city generates three unique residential patterns which are low residential density (LRD, medium residential density (MRD, and high residential density (HRD areas. Descriptive and multivariate inferential statistics were used to render explanations for the spatial variations in the residential quality variables in the study area. Findings indicated that a clear difference exists in the residential quality within the three residential density areas of Lagos. High correlations exist among the residential quality indicators and housing type. The principal component analysis shows that residential polarizations that occur in the LRD, MRD, and HRD are based on the location, dwelling facility, interior and exterior quality, neighborhood integrity, social bond, barrier to entry, and security. The practical implications of residential polarizations along the residential density areas are explicitly expressed.

  10. Analysis of long-time operation of micro-cogeneration unit with fuel cell

    Directory of Open Access Journals (Sweden)

    Patsch Marek

    2015-01-01

    Full Text Available Micro-cogeneration is cogeneration with small performance, with maximal electric power up to 50 kWe. On the present, there are available small micro-cogeneration units with small electric performance, about 1 kWe, which are usable also in single family houses or flats. These micro-cogeneration units operate on principle of conventional combustion engine, Stirling engine, steam engine or fuel cell. Micro-cogeneration units with fuel cells are new progressive developing type of units for single family houses. Fuel cell is electrochemical device which by oxidation-reduction reaction turn directly chemical energy of fuel to electric power, secondary products are pure water and thermal energy. The aim of paper is measuring and evaluation of operation parameters of micro-cogeneration unit with fuel cell which uses natural gas as a fuel.

  11. Thermal modeling of nickel-hydrogen battery cells operating under transient orbital conditions

    Science.gov (United States)

    Schrage, Dean S.

    1991-01-01

    An analytical study of the thermal operating characteristics of nickel-hydrogen battery cells is presented. Combined finite-element and finite-difference techniques are employed to arrive at a computationally efficient composite thermal model representing a series-cell arrangement operating in conjunction with a radiately coupled baseplate and coldplate thermal bus. An aggressive, low-mass design approach indicates that thermal considerations can and should direct the design of the thermal bus arrangement. Special consideration is given to the potential for mixed conductive and convective processes across the hydrogen gap. Results of a compressible flow model are presented and indicate the transfer process is suitably represented by molecular conduction. A high-fidelity thermal model of the cell stack (and related components) indicates the presence of axial and radial temperature gradients. A detailed model of the thermal bus reveals the thermal interaction of individual cells and is imperative for assessing the intercell temperature gradients.

  12. Characterisation of a Planar Solid Oxide Cell Stack Operated at Elevated Pressure

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Graves, Christopher R.; Chen, Ming

    2016-01-01

    As the global and local energy production becomes more dependent on intermittent renewable sources like wind and solar, efficient and reversible conversion of electricity to storable fuels becomes increasingly important. Solid oxide cells (SOCs) are interesting in this context since they can...... be operated either as electrolysers (SOEC) to convert electricity to fuels such as hydrogen or methane, and as fuel cells (SOFC) to convert fuels to electricity. Both productivity and conversion efficiency can be improved if the SOC operation pressure can be increased from ambient pressure to 10-30 bar. Here...... and heat exchangers is analyzed and the expected impact of pressurization on the hydrogen production cost is evaluated....

  13. Characterization of a Planar Solid Oxide Cell Stack Operated at Elevated Pressure

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Graves, Christopher R.; Chen, Ming

    2016-01-01

    As global and local energy production becomes more dependent on intermittent renewable sources like wind and solar, efficient and reversible conversion of electricity to storable fuels becomes increasingly important. Solid oxide cells (SOCs) are interesting in this context since they can...... be operated either as electrolyzers (SOEC) to convert electricity to fuels such as hydrogen or methane, and as fuel cells (SOFC) to convert fuels to electricity. Both productivity and conversion efficiency can be improved if the SOC operation pressure can be increased from ambient pressure to 10–30 bar...... in this paper. Additionally, the expected impact on the hydrogen production efficiency and cost is discussed....

  14. In-ground operation of Geothermic Fuel Cells for unconventional oil and gas recovery

    Science.gov (United States)

    Sullivan, Neal; Anyenya, Gladys; Haun, Buddy; Daubenspeck, Mark; Bonadies, Joseph; Kerr, Rick; Fischer, Bernhard; Wright, Adam; Jones, Gerald; Li, Robert; Wall, Mark; Forbes, Alan; Savage, Marshall

    2016-01-01

    This paper presents operating and performance characteristics of a nine-stack solid-oxide fuel cell combined-heat-and-power system. Integrated with a natural-gas fuel processor, air compressor, reactant-gas preheater, and diagnostics and control equipment, the system is designed for use in unconventional oil-and-gas processing. Termed a ;Geothermic Fuel Cell; (GFC), the heat liberated by the fuel cell during electricity generation is harnessed to process oil shale into high-quality crude oil and natural gas. The 1.5-kWe SOFC stacks are packaged within three-stack GFC modules. Three GFC modules are mechanically and electrically coupled to a reactant-gas preheater and installed within the earth. During operation, significant heat is conducted from the Geothermic Fuel Cell to the surrounding geology. The complete system was continuously operated on hydrogen and natural-gas fuels for ∼600 h. A quasi-steady operating point was established to favor heat generation (29.1 kWth) over electricity production (4.4 kWe). Thermodynamic analysis reveals a combined-heat-and-power efficiency of 55% at this condition. Heat flux to the geology averaged 3.2 kW m-1 across the 9-m length of the Geothermic Fuel Cell-preheater assembly. System performance is reviewed; some suggestions for improvement are proposed.

  15. Tritium and heat management in ITER Test Blanket Systems port cell for maintenance operations

    Energy Technology Data Exchange (ETDEWEB)

    Giancarli, L.M., E-mail: luciano.giancarli@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Iseli, M.; Lepetit, L.; Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Livingston, D. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom); Nevière, J.C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Pascal, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ricapito, I. [Fusion for Energy, Josep Pla, 2, Torres Diagonal Litoral B3, Barcelona E-08019 (Spain); Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Wyse, S. [Frazer-Nash Consultancy Ltd., Stonebridge House, Dorking Business Park, Dorking, Surrey RH4 1HJ (United Kingdom)

    2014-10-15

    Highlights: •The ITER TBM Program is one of the ITER missions. •We model a TBM port cell with CFD to optimize the design choices. •The heat and tritium releases management in TBM port cells has been optimized. •It is possible to reduce the T-concentration below one DAC in TBM port cells. •The TBM port cells can have human access within 12 h after shutdown. -- Abstract: Three ITER equatorial port cells are dedicated to the assessment of six different designs of breeding blankets, known as Test Blanket Modules (TBMs). Several high temperature components and pipework will be present in each TBM port cell and will release a significant quantity of heat that has to be extracted in order to avoid the ambient air and concrete wall temperatures to exceed allowable limits. Moreover, from these components and pipes, a fraction of the contained tritium permeates and/or leaks into the port cell. This paper describes the optimization of the heat extraction management during operation, and the tritium concentration control required for entry into the port cell to proceed with the required maintenance operations after the plasma shutdown.

  16. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  17. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  18. Residential solar-heating system

    Science.gov (United States)

    1978-01-01

    Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

  19. Convergence of Residential Gateway Technology

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Balm, M.; Jong, C.M. de; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  20. Convergence of residential gateway technology

    NARCIS (Netherlands)

    Hartog, den F.T.H.; Balm, M.; Jong, de C.M.; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  1. Trends of Sustainable Residential Architecture

    OpenAIRE

    Narvydas, A

    2014-01-01

    The article is based on Master’s research conducted during Scottish Housing Expo 2010. The aim of the research was to determine the prevailing trends in sustainable residential architecture. Each trend can be described by features detected during visual and technical observation of project data. Based on that architects may predict possible problems related to a specific trend.

  2. Reduce tax on residential mobility

    NARCIS (Netherlands)

    van Ewijk, C.; van Leuvensteijn, M.

    2010-01-01

    How can Europe increase structural growth? This column argues that labour market flexibility is key. As a major barrier to labour movement is rigidity in the housing market, abolishing transfer taxes on residential property could result in gains of up to 0.4% of GDP.

  3. Zones 30 : urban residential areas.

    NARCIS (Netherlands)

    2006-01-01

    Sustainable Safety uses a road categorization in which through traffic is concentrated on motorways and other main roads. In residential areas, which have a living, shopping, or work function, through traffic is discouraged by setting a speed limit of 30 km/h, and by speed reducing measures such as

  4. High pressure operation of tubular solid oxide fuel cells and their intergration with gas turbines

    Energy Technology Data Exchange (ETDEWEB)

    Haynes, C.; Wepfer, W.J. [Georgia Institute of Technology, Atlanta, GA (United States)

    1996-12-31

    Fossil fuels continue to be used at a rate greater than that of their natural formation, and the current byproducts from their use are believed to have a detrimental effect on the environment (e.g. global warming). There is thus a significant impetus to have cleaner, more efficient fuel consumption alternatives. Recent progress has led to renewed vigor in the development of fuel cell technology, which has been shown to be capable of producing high efficiencies with relatively benign exhaust products. The tubular solid oxide fuel cell developed by Westinghouse Electric Corporation has shown significant promise. Modeling efforts have been and are underway to optimize and better understand this fuel cell technology. Thus far, the bulk of modeling efforts has been for operation at atmospheric pressure. There is now interest in developing high-efficiency integrated gas turbine/solid oxide fuel cell systems. Such operation of fuel cells would obviously occur at higher pressures. The fuel cells have been successfully modeled under high pressure operation and further investigated as integrated components of an open loop gas turbine cycle.

  5. Residential proximinity, perceived and acceptable risk

    International Nuclear Information System (INIS)

    Rogers, G.O.

    1984-01-01

    This paper focuses on the relationship between the life experiences associated with residential proximity, and the perception and acceptability of the risks associated with generating electricity in nuclear power plants. Perceived risk is operationally defined in terms of estimated likelihood of occurrence, while acceptability of nuclear power is defined in terms of people's favorable or unfavorable opinions regarding nuclear power plants. In the context of a simple social-structural model of perceived and acceptable risk, four potential explanations for enhanced acceptability among those residentially proximate with nuclear facilities are examined: residents, through the experience of living with hazard, are reinforced toward assigning lower probabilities to the potential risks associated with nuclear facilities; the cognitive dissonance created by the acceptance of the risks associated with nuclear power is decreased by reducing perceived risk; nuclear neighbors are predisposed toward, educated about, and/or economically dependent upon nuclear power hence the more favorable attitudes toward it; nearby residents are systematically more altruistic--other oriented--than the general population and thus more willing to bear the risks associated with nuclear power

  6. TOF-SIMS characterization of impurity enrichment and redistribution in solid oxide electrolysis cells during operation

    DEFF Research Database (Denmark)

    Kiebach, Wolff-Ragnar; Norrman, Kion; Chatzichristodoulou, Christodoulos

    2014-01-01

    cathode. The surfaces and cross-sections of the cells were analyzed, and several elemental impurities like Si, Ca and Na were identified and spatially mapped and their enrichment and migration during operation is reported. With advancing operation time, the concentration of these elements, especially Na...... and Ca, increases. For Si, a concentration gradient is found from the gas inlet to the gas outlet. Additionally, a loss of Ni percolation in the active cathode is observed in the same area where the Si enrichment is found. Based on the obtained TOF-SIMS results, the influence of the operating conditions...

  7. Evaluation of the radial design of fuel cells in an operation cycle of a BWR reactor

    International Nuclear Information System (INIS)

    Gonzalez C, J.; Martin del Campo M, C.

    2003-01-01

    This work is continuation of one previous in the one that the application of the optimization technique called Tabu search to the radial design of fuel cells of boiling water reactors (BWR, Boiling Water Reactor) is presented. The objective function used in the optimization process only include neutron parameters (k-infinite and peak of radial power) considering the cell at infinite media. It was obtained to reduce the cell average enrichment completing the characteristics of reactivity of an original cell. The objective of the present work is to validate the objective function that was used for the radial design of the fuel cell (test cell), analyzing the operation of a one cycle of the reactor in which fuels have been fresh recharged that contain an axial area with the nuclear database of the cell designed instead of the original cell. For it is simulated it with Cm-Presto the cycle 10 of the reactor operation of the Unit 1 of the Nuclear Power station of Laguna Verde (U1-CNLV). For the cycle evaluation its were applied so much the simulation with the Haling strategy, as the simulation of the one cycle with control rod patterns and they were evaluated the energy generation and several power limits and reactivity that are used as design parameters in fuel reloads of BWR reactors. The results at level of an operation cycle of the reactor, show that the objective function used in the optimization and radial design of the cell is adequate and that it can induce to one good use of the fuel. (Author)

  8. Circulating miRNAs as biomarkers for oral squamous cell carcinoma recurrence in operated patients

    DEFF Research Database (Denmark)

    Yan, Yan; Wang, Xuan; Venø, Morten Trillingsgaard

    2017-01-01

    MicroRNAs (miRNAs) are small regulatory non-coding RNAs for which altered expression in cancers can serve as potential biomarkers for diseases. We here investigated whether circulating miRNAs can serve as biomarkers for predicting post-operational recurrence of oral squamous cell carcinoma (OSCC...

  9. Low stoichiometry operation of a polymer electrolyte membrane fuel cell employing the interdigitated flow field design

    DEFF Research Database (Denmark)

    Berning, Torsten; Odgaard, Madeleine; Kær, Søren Knudsen

    2011-01-01

    Fuel cell operation on dry reactant gases under low stoichiometry conditions employing the interdigitated flow field is investigated using a multi-fluid model. It is assumed that the MEA contains a water uptake layer which facilitates water absorption to the membrane and hence prevents the anode...

  10. Periodic Virtual Cell Manufacturing (P-VCM) - Concept, Design and Operation

    NARCIS (Netherlands)

    Slomp, Jannes; Krushinsky, Dimitry; Caprihan, Rahul

    2011-01-01

    This paper presents and discusses the concept of Periodic Virtual Cell Manufacturing (P-VCM). After giving an illustrative example of the operation and design complexity of a P-VCM system, we present an industrial case to study the applicability of the concept. The illustrative example and the

  11. Reversing and Repairing Microstructure Degradation in Solid Oxide Cells During Operation

    DEFF Research Database (Denmark)

    Graves, Christopher R.

    2013-01-01

    density by reversible battery-like operation, cycling between electrolysis mode and fuel-cell mode. Also reported are new examples of beneficial effects of (2) redox cycling, (3) exsolution of nano-catalysts, and (4) high cathodic polarization, all of which can be used to maintain or even improve...

  12. New operational modes for the Ta2O5-based electrolyte conductance cell

    NARCIS (Netherlands)

    Olthuis, Wouter; Smith, A.; van der Zalm, R.A.J.; Bergveld, Piet

    1994-01-01

    Based on the recently presented conductance cell, two specific operational modes are proposed. In the oscillator mode, the conductivity of the electrolyte determines the frequency of an oscillator, experimentally obtaining a shift from 10 to 27 kHz for a KCl concentration range from 0.5 to 100 mM.

  13. Combined local current distribution measurements and high resolution neutron radiography of operating direct methanol fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Alexander; Wippermann, Klaus [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy Research, IEF-3: Fuel Cells; Sanders, Tilman [RWTH Aachen (DE). Inst. for Power Electronics and Electrical Drives (ISEA); Arlt, Tobias [Helmholtz Centre Berlin (Germany). Inst. for Applied Materials

    2010-07-01

    Neutron radiography allows the investigation of the local fluid distribution in direct methanol fuel cells (DMFCs) under operating conditions. Spatial resolutions in the order of some tens of micrometers at the full test cell area are achieved. This offers the possibility to study practice-oriented, large stack cells with an active area of several hundred cm{sup 2} as well as specially designed, small test cells with an area of some cm{sup 2}. Combined studies of high resolution neutron radiography and segmented cell measurements are especially valuable, because they enable a correlation of local fluid distribution and local performance [1, 2]. The knowledge of this interdependency is essential to optimise the water management and performance respecting a homogeneous fluid, current and temperature distribution and to achieve high performance and durability of DMFCs. (orig.)

  14. How to develop a Standard Operating Procedure for sorting unfixed cells

    Science.gov (United States)

    Schmid, Ingrid

    2012-01-01

    Written Standard Operating Procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. PMID:22381383

  15. Influence of operation and irradiation on cell-mediated immunity in patients with oral cancer

    International Nuclear Information System (INIS)

    Tominaga, Kazuhiro; Tominaga, Naohiro; Tokuhisa, Michio

    1995-01-01

    To evaluate the influence of operation and irradiation on cell-mediated immunity in patients with primary oral squamous cell carcinoma, several parameters, including NK activity, LAK activity, and IL-2 production, were selected. Twenty-two patients who underwent operation and/or irradiation from 1989 to 1993 were evaluated. Perioperatively, no significant change of immunologic parameters was observed except increased number of peripheral leukocytes at two weeks after operation. Immediately and/or one month after irradiation, significantly decreased numbers of leukocytes and lymphocytes as well as significantly depressed levels of blastoid transformation of lymphocytes, LAK activity, and IL-2 production were observed. By three months after irradiation, values of immunologic parameters returned to preirradiation values. The number of monocytes and level of NK activity showed little change after irradiation. (author)

  16. Acid-doped Polybenzimidazole Membranes as Electrolyte for Fuel Cells Operating Above 100°C

    DEFF Research Database (Denmark)

    Qingfeng, Li; Jensen, Jens Oluf; He, Ronhuan

    2003-01-01

    The technical achievement and challenges for the PEMFC technology based on perfluorosulfonic acid (PFSA) polymer membranes (e.g. Nafion®) are briefly discussed. The newest development in the field is alternative polymer electrolytes for operation above 100°C. As one of the successful approaches...... to high operational temperatures, the development and evaluation of acid doped PBI membranes are reviewed, covering polymer synthesis, membrane casting, acid doping, physiochemical characterization and fuel cell tests. A high temperature PEMFC system operational at up to 200°C is demonstrated with no gas...... humidification and high CO-tolerance up to 10 vol%. This high CO tolerance allows for a direct use of reformed hydrogen without further CO removal, which opens the possibility for an integrated reformer-fuel cell system. The content of this review is to a large extent based on research performed by the authors...

  17. How to develop a standard operating procedure for sorting unfixed cells.

    Science.gov (United States)

    Schmid, Ingrid

    2012-07-01

    Written standard operating procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Air-processed organic tandem solar cells on glass: toward competitive operating lifetimes

    DEFF Research Database (Denmark)

    Adams, Jens; Spyropoulos, George D.; Salvador, Michael

    2015-01-01

    efficiencies of more than 10% the rather limited stability of this type of devices raises concerns towards future commercialization. The tandem concept allows for both absorbing a broader range of the solar spectrum and reducing thermalization losses. We designed an organic tandem solar cell with an inverted...... device geometry comprising environmentally stable active and charge-selecting layers. Under continuous white light irradiation, we demonstrate an extrapolated, operating lifetime in excess of one decade. We elucidate that for the current generation of organic tandem cells one critical requirement...... for long operating lifetimes consists of periodic UV light treatment. These results suggest that new material approaches towards UV-resilient active and interfacial layers may enable efficient organic tandem solar cells with lifetimes competitive with traditional inorganic photovoltaics....

  19. Preliminary estimation of the dose rates of the operation room of the RPR radioisotope cell

    International Nuclear Information System (INIS)

    Rocha, A.C.S.; Silva, J.J.G.; Pina, J.L.S. de; Fajardo, P.W.

    1986-07-01

    During the preliminary studies, about the installations layout of a radioisotope production reactor, the possibility of construction of a radioisotope cell at the reactor building has been investigated. The decisions about that construction has considered mainly the level of the radiation dose over the cell operator. The dose rate has been calculated based on: neutron flux and gamma radiation from fission products and activation materials inside the reactor; volatile fission products such as noble gases and iodides; tritium form ternary fission. The objective was calculate the radiation dose over the cell operator during a journey of 8 hours of work per day. For those calculations some data have been obtained from the Angra-3 reactor. (author)

  20. Comparison of Four Probabilistic Models (CARES, Calendex, ConsEspo, SHEDS) to Estimate Aggregate Residential Exposures to Pesticides

    Science.gov (United States)

    Two deterministic models (US EPA’s Office of Pesticide Programs Residential Standard Operating Procedures (OPP Residential SOPs) and Draft Protocol for Measuring Children’s Non-Occupational Exposure to Pesticides by all Relevant Pathways (Draft Protocol)) and four probabilistic mo...

  1. Branching out to residential lands: Missions and strategies of five tree distribution programs in the U.S.

    Science.gov (United States)

    Vi D. Nguyen; Lara A. Roman; Dexter H. Locke; Sarah K. Mincey; Jessica R. Sanders; Erica Smith Fichman; Mike Duran-Mitchell; Sarah Lumban Tobing

    2017-01-01

    Residential lands constitute a major component of existing and possible tree canopy in many cities in the United States. To expand the urban forest on these lands, some municipalities and nonprofit organizations have launched residential yard tree distribution programs, also known as tree giveaway programs. This paper describes the operations of five tree distribution...

  2. Using super-capacitors in combination with Bi-directional DC/DC converters for active load management in residential fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Cacciato, M.; Giulii Capponi, F. [Rome Univ., ' La Sapienza' , Dept. of Electrical Engineering (Italy)

    2004-07-01

    Among innovative conversion systems for alternative energy, Fuel Cells (FCs) are ideal in applications as distributed power generation or automotive. The connection of FCs to domestic or industrial loads requires a DC/AC converter also acting as a energy buffer to match the different dynamics of FCs and loads. In the last years, a new type of electrolytic capacitors called Super- Capacitors (SCs), has been designed using double layers technology. Such components are able to store more energy than electrolytic capacitors maintaining the capability to swap it at high power levels. Firstly, different solution used to connect SCs to a FC based conversion system are considered. Then, a comparison of bi-directional DC/DC converters designed to manage SCs energy is performed. Finally, the converter design and a laboratory prototype of the adopted solution are reported. (authors)

  3. Particulate emissions from residential wood combustion

    DEFF Research Database (Denmark)

    Luis Teles de Carvalho, Ricardo; Jensen, Ole Michael; Tarelho, Luis A. C.

    Residential wood combustion (RWC) in fireplaces and conventional appliances is the main contributor to fine particulate matter (PM2.5) emissions in Denmark and Portugal representing more than 30% of the total emissions [1;2]. Such estimations are uncertain concerning the wood consumption...... and official emission factors, not taking into account actual burning conditions in dwellings [3]. There is limited knowledge on the real-life performance and spatial distribution of existing appliance types. Few studies have been targeting to understand the influence of fuel operation habits on PM2...... the available estimations for Denmark and Portugal, suggesting a methodology to increase the accuracy of activity data and emission factors. This work is based on new studies carried out to quantify the PM2.5 emissions in daily life through field experiments in Danish dwellings and by considering typical...

  4. EFFECT SIGNIFICANCE ASSESSMENT OF THE THERMODYNAMICAL FACTORS ON THE SOLID OXIDE FUEL CELL OPERATION

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2015-01-01

    Full Text Available Technologies of direct conversion of the fuel energy into electrical power are an upcoming trend in power economy. Over the last decades a number of countries have created industrial prototypes of power plants on fuel elements (cells, while fuel cells themselves became a commercial product on the world energy market. High electrical efficiency of the fuel cells allows predictting their further spread as part of hybrid installations jointly with gas and steam turbines which specifically enables achieving the electrical efficiency greater than 70 %. Nevertheless, investigations in the area of increasing efficiency and reliability of the fuel cells continue. Inter alia, research into the effects of oxidizing reaction thermodynamic parameters, fuel composition and oxidation reaction products on effectiveness of the solid oxide fuel cells (SOFC is of specific scientific interest. The article presents a concise analysis of the fuel type effects on the SOFC efficiency. Based on the open publications experimental data and the data of numerical model studies, the authors adduce results of the statistical analysis of the SOFC thermodynamic parameters effect on the effectiveness of its functioning as well as of the reciprocative factors of these parameters and gas composition at the inlet and at the outlet of the cell. The presented diagrams reflect dimension of the indicated parameters on the SOFC operation effectiveness. The significance levels of the above listed factors are ascertained. Statistical analysis of the effects of the SOFC functionning process thermodynamical, consumption and concentration parameters demonstrates quintessential influence of the reciprocative factors (temperature – flow-rate and pressure – flow-rate and the nitrogen N2 and oxygen O2 concentrations on the operation efficiency in the researched range of its functioning. These are the parameters to be considered on a first-priority basis while developing mathematical models

  5. TESTING AND PERFORMANCE ANALYSIS OF NASA 5 CM BY 5 CM BI-SUPPORTED SOLID OXIDE ELECTROLYSIS CELLS OPERATED IN BOTH FUEL CELL AND STEAM ELECTROLYSIS MODES

    Energy Technology Data Exchange (ETDEWEB)

    R. C. O' Brien; J. E. O' Brien; C. M. Stoots; X. Zhang; S. C. Farmer; T. L. Cable; J. A. Setlock

    2011-11-01

    A series of 5 cm by 5 cm bi-supported Solid Oxide Electrolysis Cells (SOEC) were produced by NASA for the Idaho National Laboratory (INL) and tested under the INL High Temperature Steam Electrolysis program. The results from the experimental demonstration of cell operation for both hydrogen production and operation as fuel cells is presented. An overview of the cell technology, test apparatus and performance analysis is also provided. The INL High Temperature Steam Electrolysis laboratory has developed significant test infrastructure in support of single cell and stack performance analyses. An overview of the single cell test apparatus is presented. The test data presented in this paper is representative of a first batch of NASA's prototypic 5 cm by 5 cm SOEC single cells. Clearly a significant relationship between the operational current density and cell degradation rate is evident. While the performance of these cells was lower than anticipated, in-house testing at NASA Glenn has yielded significantly higher performance and lower degradation rates with subsequent production batches of cells. Current post-test microstructure analyses of the cells tested at INL will be published in a future paper. Modification to cell compositions and cell reduction techniques will be altered in the next series of cells to be delivered to INL with the aim to decrease the cell degradation rate while allowing for higher operational current densities to be sustained. Results from the testing of new batches of single cells will be presented in a future paper.

  6. Testing And Performance Analysis Of NASA 5 CM BY 5 CM Bi-Supported Solid Oxide Electrolysis Cells Operated In Both Fuel Cell And Steam Electrolysis Modes

    International Nuclear Information System (INIS)

    O'Brien, R.C.; O'Brien, J.E.; Stoots, C.M.; Zhang, X.; Farmer, S.C.; Cable, T.L.; Setlock, J.A.

    2011-01-01

    A series of 5 cm by 5 cm bi-supported Solid Oxide Electrolysis Cells (SOEC) were produced by NASA for the Idaho National Laboratory (INL) and tested under the INL High Temperature Steam Electrolysis program. The results from the experimental demonstration of cell operation for both hydrogen production and operation as fuel cells is presented. An overview of the cell technology, test apparatus and performance analysis is also provided. The INL High Temperature Steam Electrolysis laboratory has developed significant test infrastructure in support of single cell and stack performance analyses. An overview of the single cell test apparatus is presented. The test data presented in this paper is representative of a first batch of NASA's prototypic 5 cm by 5 cm SOEC single cells. Clearly a significant relationship between the operational current density and cell degradation rate is evident. While the performance of these cells was lower than anticipated, in-house testing at NASA Glenn has yielded significantly higher performance and lower degradation rates with subsequent production batches of cells. Current post-test microstructure analyses of the cells tested at INL will be published in a future paper. Modification to cell compositions and cell reduction techniques will be altered in the next series of cells to be delivered to INL with the aim to decrease the cell degradation rate while allowing for higher operational current densities to be sustained. Results from the testing of new batches of single cells will be presented in a future paper.

  7. Durability study and lifetime prediction of baseline proton exchange membrane fuel cell under severe operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Marrony, M.; Quenet, S.; Aslanides, A. [European Institute for Energy Research, Emmy-Noether Strasse 11, 76131 Karlsruhe (Germany); Barrera, R.; Ginocchio, S.; Montelatici, L. [Edison, Via Giorgio La Pira 2, 10028 Trofarello (Italy)

    2008-08-01

    Comparative studies of mechanical and electrochemical properties of Nafion{sup registered} - and sulfonated polyetheretherketone polymer-type membranes are carried out under severe fuel cell conditions required by industrials, within stationary and cycling electric load profiles. These membranes are proposed to be used in PEM between 70 and 90 C as fluorinated or non-fluorinated baseline membranes, respectively. Thus, though the performance of both membranes remains suitable, Nafion{sup registered} backbone brought better mechanical properties and higher electrochemical stabilities than sulfonated polyetheretherketone backbone. The performance stability and the mechanical strength of the membrane-electrode assembly were shown to be influenced by several intrinsic properties of the membrane (e.g., thermal pre-treatment, thickness) and external conditions (fuel cell operating temperature, relative humidity). Finally, a lifetime prediction for membranes under stationary conditions is proposed depending on the operation temperature. At equivalent thicknesses (i.e. 50 {mu}m), Nafion{sup registered} membranes were estimated able to operate into the 80-90 C range while sulfonated polyetheretherketone would be limited into the 70-80 C range. This approach brings baseline information about the capability of these types of polymer electrolyte membrane under fuel cell critical operations. Finally, it is revealed as a potential tool for the selection of the most promising advanced polymers for the ensuing research phase. (author)

  8. Optimization of design and operating parameters in a pilot scale Jameson cell for slime coal cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Hacifazlioglu, Hasan; Toroglu, Ihsan [Department of Mining Engineering, University of Karaelmas, 67100 (Turkey)

    2007-07-15

    The Jameson flotation cell has been commonly used to treat a variety of ores (lead, zinc, copper etc.), coal and industrial minerals at commercial scale since 1989. It is especially known to be highly efficient at fine and ultrafine coal recovery. However, although the Jameson cell has quite a simple structure, it may be largely inefficient if the design and operating parameters chosen are not appropriate. In this study, the design and operating parameters of a pilot scale Jameson cell were optimized to obtain a desired metallurgical performance in the slime coal flotation. The optimized design parameters are the nozzle type, the height of the nozzle above the pulp level, the downcomer diameter and the immersion depth of the downcomer. Among the operating parameters optimized are the collector dosage, the frother dosage, the percentage of solids and the froth height. In the optimum conditions, a clean coal with an ash content of 14.90% was obtained from the sample slime having 45.30% ash with a combustible recovery of 74.20%. In addition, a new type nozzle was developed for the Jameson cell, which led to an increase of about 9% in the combustible recovery value.

  9. Bioreactor design for successive culture of anchorage-dependent cells operated in an automated manner.

    Science.gov (United States)

    Kino-Oka, Masahiro; Ogawa, Natsuki; Umegaki, Ryota; Taya, Masahito

    2005-01-01

    A novel bioreactor system was designed to perform a series of batchwise cultures of anchorage-dependent cells by means of automated operations of medium change and passage for cell transfer. The experimental data on contamination frequency ensured the biological cleanliness in the bioreactor system, which facilitated the operations in a closed environment, as compared with that in flask culture system with manual handlings. In addition, the tools for growth prediction (based on growth kinetics) and real-time growth monitoring by measurement of medium components (based on small-volume analyzing machinery) were installed into the bioreactor system to schedule the operations of medium change and passage and to confirm that culture proceeds as scheduled, respectively. The successive culture of anchorage-dependent cells was conducted with the bioreactor running in an automated way. The automated bioreactor gave a successful culture performance with fair accordance to preset scheduling based on the information in the latest subculture, realizing 79- fold cell expansion for 169 h. In addition, the correlation factor between experimental data and scheduled values through the bioreactor performance was 0.998. It was concluded that the proposed bioreactor with the integration of the prediction and monitoring tools could offer a feasible system for the manufacturing process of cultured tissue products.

  10. Residential mobility and childhood leukemia.

    Science.gov (United States)

    Amoon, A T; Oksuzyan, S; Crespi, C M; Arah, O A; Cockburn, M; Vergara, X; Kheifets, L

    2018-07-01

    Studies of environmental exposures and childhood leukemia studies do not usually account for residential mobility. Yet, in addition to being a potential risk factor, mobility can induce selection bias, confounding, or measurement error in such studies. Using data collected for California Powerline Study (CAPS), we attempt to disentangle the effect of mobility. We analyzed data from a population-based case-control study of childhood leukemia using cases who were born in California and diagnosed between 1988 and 2008 and birth certificate controls. We used stratified logistic regression, case-only analysis, and propensity-score adjustments to assess predictors of residential mobility between birth and diagnosis, and account for potential confounding due to residential mobility. Children who moved tended to be older, lived in housing other than single-family homes, had younger mothers and fewer siblings, and were of lower socioeconomic status. Odds ratios for leukemia among non-movers living mobility, including dwelling type, increased odds ratios for leukemia to 2.61 (95% CI: 1.76-3.86) for living mobility of childhood leukemia cases varied by several sociodemographic characteristics, but not by the distance to the nearest power line or calculated magnetic fields. Mobility appears to be an unlikely explanation for the associations observed between power lines exposure and childhood leukemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. RESIDENTIAL MORTGAGE IN MODERN RUSSIA

    Directory of Open Access Journals (Sweden)

    Dementiev N. P.

    2015-03-01

    Full Text Available The article presents a comparative analysis of residential mortgages in Russia and the United States. The primary ways of mortgage refinancing are outlined. Predominance of the elements of two-level refinancing system of residential mortgage in Russia and the United States is shown. The activity of the Agency for Housing Mortgage Lending (AHML, the basic tool of the Russian government’s mortgage policy, is described in detail. In its objectives and functions the AHML is similar to the American mortgage agencies Ginnie Mae, Fannie Mae and Freddie Mac. Similarities were identified in the Russian and US residential mortgages in the pre-crisis period (high rates of mortgage growth, favourable economic conjuncture, low interest rates, large increase in house prices, speculative housing demand. During the mortgage crisis, the policies of the Russian and US governments and monetary authorities had also much in common (monetary policy easing, cheap central banks loans, extended facilities of mortgage refinancing on the part of state agencies, mortgage rescue scheme, social mortgage programs. But the scope of mortgage in Russia is enormously narrow as compared to the US mortgage. The most important reason for that - low incomes of the Russian population.

  12. Increasing Fuel Efficiency of Direct Methanol Fuel Cell Systems with Feedforward Control of the Operating Concentration

    Directory of Open Access Journals (Sweden)

    Youngseung Na

    2015-09-01

    Full Text Available Most of the R&D on fuel cells for portable applications concentrates on increasing efficiencies and energy densities to compete with other energy storage devices, especially batteries. To improve the efficiency of direct methanol fuel cell (DMFC systems, several modifications to system layouts and operating strategies are considered in this paper, rather than modifications to the fuel cell itself. Two modified DMFC systems are presented, one with an additional inline mixer and a further modification of it with a separate tank to recover condensed water. The set point for methanol concentration control in the solution is determined by fuel efficiency and varies with the current and other process variables. Feedforward concentration control enables variable concentration for dynamic loads. Simulation results were validated experimentally with fuel cell systems.

  13. Degradation of Solid Oxide Electrolysis Cells Operated at High Current Densities

    DEFF Research Database (Denmark)

    Tao, Youkun; Ebbesen, Sune Dalgaard; Mogensen, Mogens Bjerg

    2014-01-01

    In this work the durability of solid oxide cells for co-electrolysis of steam and carbon dioxide (45 % H2O + 45 % CO2 + 10 % H2) at high current densities was investigated. The tested cells are Ni-YSZ electrode supported, with a YSZ electrolyte and either a LSM-YSZ or LSCF-CGO oxygen electrode....... A current density of -1.5 and -2.0 A/cm2 was applied to the cell and the gas conversion was 45 % and 60 %, respectively. The cells were operated for a period of up to 700 hours. The electrochemical analysis revealed significant performance degradation for the ohmic process, oxygen ion interfacial transfer...

  14. Residential and commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Svendsen, Svend; Furbo, S.

    2012-11-15

    Low-energy buildings can make a major contribution to general sustainable development by providing a solution to problems related to the use of fossil fuels. The EPBD (EU Directive on Energy Performance of Buildings) requirements that by 2020 new building shall be constructed to use nearly zero energy, and no fossil fuels, can be accomplished by combining low-energy buildings with renewable energy via low-temperature district heating in cities and suburbs, and via heat pumps for low-density settlements. Based on experience with passive houses, low-energy buildings meeting the energy performance requirements of 2020 are expected to cost only a few percent more than conventional buildings. The very large and rapid changes needed in the energy performance of buildings is a challenge for the building sector, but one that can be overcome by better methods of developing products and designing, constructing and operating buildings. Simulation-based analysis and optimisation, and considerations of durability, will be important here. Building may thus be transformed from an experience-based sector to one based on knowledge and research, with high-quality sustainable products and good business opportunities. (Author)

  15. Residential solar hot water

    Energy Technology Data Exchange (ETDEWEB)

    1982-06-01

    This report examines the feasibility of using solar energy to preheat domestic water coming from the city supply at a temperature of approximately 4{degree}C. Four solar collectors totalling 7 m{sup 2} were installed on a support structure facing south at an angle of 60{degree} from the horizontal. The system worked most efficiently in the spring and early summer when the combination of long hours of sunshine, clean air and clear skies allowed for maximum availability of solar radiation. Performance dropped in late summer and fall mainly due to cloudier weather conditions. The average temperature in the storage tank over the 10 months of operation was 42{degree}C, ranging from a high of 83{degree}C in July to a low of 6{degree}C in November. The system provided a total of 7.1 GJ, which is approximately one-third the annual requirement for domestic hot water heating. At the present time domestic use of solar energy to heat water does not appear to be economically viable. High capital costs are the main problem. As a solar system with present day technology can only be expected to meet half to two-thirds of the hot water energy demand the savings are not sufficient for the system to pay for itself within a few years. 5 figs.

  16. Increasing the operation temperature of polymer electrolyte membranes for fuel cells: From nanocomposites to hybrids

    Science.gov (United States)

    Licoccia, Silvia; Traversa, Enrico

    Among the possible systems investigated for energy production with low environmental impact, polymeric electrolyte membrane fuel cells (PEMFCs) are very promising as electrochemical power sources for application in portable technology and electric vehicles. For practical applications, operating FCs at temperatures above 100 °C is desired, both for hydrogen and methanol fuelled cells. When hydrogen is used as fuel, an increase of the cell temperature produces enhanced CO tolerance, faster reaction kinetics, easier water management and reduced heat exchanger requirement. The use of methanol instead of hydrogen as a fuel for vehicles has several practical benefits such as easy transport and storage, but the slow oxidation kinetics of methanol needs operating direct methanol fuel cells (DMFCs) at intermediate temperatures. For this reason, new membranes are required. Our strategy to achieve the goal of operating at temperatures above 120 °C is to develop organic/inorganic hybrid membranes. The first approach was the use of nanocomposite class I hybrids where nanocrystalline ceramic oxides were added to Nafion. Nanocomposite membranes showed enhanced characteristics, hence allowing their operation up to 130 °C when the cell was fuelled with hydrogen and up to 145 °C in DMFCs, reaching power densities of 350 mW cm -2. The second approach was to prepare Class II hybrids via the formation of covalent bonds between totally aromatic polymers and inorganic clusters. The properties of such covalent hybrids can be modulated by modifying the ratio between organic and inorganic groups and the nature of the chemical components allowing to reach high and stable conductivity values up to 6.4 × 10 -2 S cm -1 at 120 °C.

  17. Operating experience and radiation protection problems in the working of the radio-metallurgy hot cell facilities at BARC

    International Nuclear Information System (INIS)

    Janardhanan, S.; Watamwar, S.B.; Mehta, S.K.; Pillai, P.M.B.; John, Jacob; Kutty, K.N.

    1977-01-01

    The Bhabha Atomic Research Centre at Bombay has six hot cell facilities for radiometallurgical investigations of irradiated/failed fuel elements. The hot cell facilities have been provided with certain built-in safety features, a ventilation system, radiation monitoring instruments for various purposes, a centralised air monitoring system and a central panel for display of various alarms. Procedures adopted for radiation protection and contamination control include : (1) radiation leak test for cells and filter efficiency evaluation before cell activation, (2) practices to be followed by frog suit personnel while working in hot cell areas, (3) receipt and handling of irradiated fuel elements, (4) cell filter change operation, (5) checks on high level drains and (6) effluent discharge and waste shipments. Operating experience in the working of these facilities along with radiation accident incidents is described. Data regarding release of activity during normal cell operations, dose rates during various metallurgical operations and personnel exposures are presented. (M.G.B.)

  18. The design, construction, and operation of the Integrated Radwaste Treatment System (IRTS) Drum Cell

    International Nuclear Information System (INIS)

    Landau, B.; Russillo, A.; Frank, D.; Garland, D.

    1989-12-01

    This report describes the design, construction, and the operation of the Integrated Radwaste Treatment Systems (IRTS) Drum Cell at the West Valley Demonstration Project (WVDP), West Valley, New York. The IRTS Drum Cell was designed to provide a shielded, secure storage area for the remote handling and placement of low-level Class C radioactive waste produced in the IRTS. The Drum Cell was designed to contain up to approximately 8,804 drums from decontaminated supernatant processing. This waste is to be poured into 0.27m 3 in a temperature controlled environment to ensure the cement will not be subjected to freezing and thawing cycles. A Temporary Weather Structure (TWS), a pre-engineered building, now encloses the Drum Cell and associated equipment so that remote waste-handling and placement operations can continue without regard to weather conditions. The Drum Cell was designed so that this TWS could be removed and the low-level waste entombed in place. Final disposition of this low-level waste is currently being evaluated in an Environmental Impact Statement (EIS). 10 refs., 11 figs., 1 tab

  19. Impact of cell design and operating conditions on the performances of SOFC fuelled with methane

    Science.gov (United States)

    Laurencin, J.; Lefebvre-Joud, F.; Delette, G.

    An in-house-model has been developed to study the thermal and electrochemical behaviour of a planar SOFC fed directly with methane and incorporated in a boiler. The usual Ni-YSZ cermet has been considered for the anode material. It has been found that methane reforming into hydrogen occurs only at the cell inlet in a limited depth within the anode. A sensitivity analysis has allowed establishing that anode thicknesses higher than ∼400-500 μm are required to achieve both the optimal methane conversion and electrochemical performances. The direct internal reforming (DIR) mechanisms and the impact of operating conditions on temperature gradients and SOFC electrical efficiencies have been investigated considering the anode supported cell configuration. It has been shown that the temperature gradient is minimised in the autothermal mode of cell operation. Thermal equilibrium in the stack has been found to be strongly dependent on radiative heat losses with the stack envelope. Electrochemical performance and cell temperature maps have been established as a function of methane flow rates and cell voltages.

  20. Regionalised tertiary psychiatric residential facilities.

    Science.gov (United States)

    Lesage, Alain; Groden, David; Goldner, Elliot M; Gelinas, Daniel; Arnold, Leslie M

    2008-01-01

    Psychiatric hospitals remain the main venue for long-term mental health care and, despite widespread closures and downsizing, no country that built asylums in the last century has done away with them entirely--with the recent exception of Italy. Differentiated community-based residential alternatives have been developed over the past decades, with staffing levels that range from full-time professional, to daytime only, to part-time/on-call. This paper reviews the characteristics of community-based psychiatric residential care facilities as an alternative to long-term care in psychiatric hospitals. It describes five factors decision makers should consider: 1. number of residential places needed; 2. staffing levels; 3. physical setting; 4. programming; and 5. governance and financing. In Italy, facilities with full-time professional staff have been developed since the mid-1990s to accommodate the last cohorts of patients discharged from psychiatric hospitals. In the United Kingdom, experiments with hostel wards since the 1980s have shown that home-like, small-scale facilities with intensive treatment and rehabilitation programming can be effective for the most difficult-to-place patients. More recently in Australia, Community Care Units (CCUs) have been applying this concept. In the Canadian province of British Columbia (BC), Tertiary Psychiatric Residential Facilities (TPRFs) have been developed as part of an effort to regionalise health and social services and downsize and ultimately close its only psychiatric hospital. This type of service must be further developed in addition to the need for forensic, acute-care and intermediate-level beds, as well as for community-based care such as assertive community treatment and intensive case management. All these types of services, together with long-term community-based residential care, constitute the elements of a balanced mental health care system. As part of a region's balanced mental health care plan, these Tertiary

  1. The effect of test configuration on the true operating conditions of PEM fuel cells. Paper no. IGEC-1-124

    International Nuclear Information System (INIS)

    Simpson, T.; Li, X.

    2005-01-01

    The operating conditions of a single PEM fuel cell can be significantly affected by the configuration in which the fuel cell test is setup. This study investigates the effect on the gas dewpoint temperature of not insulating the inlet fittings to a PEM fuel cell and the effect of non-optimal stack control thermocouple placement on fuel cell stack operating temperature. Both of these setup configurations can significantly affect fuel cell membrane humidification conditions, especially in a single fuel cell as demonstrated through the sample test conditions presented in this paper. (author)

  2. A simple nanostructured polymer/ZnO hybrid solar cell - preparation and operation in air

    DEFF Research Database (Denmark)

    Krebs, Frederik C; Thomann, Yi; Thomann, Ralf

    2008-01-01

    without notable loss in efficiency. The devices do not require any form of encapsulation to gain stability, while a barrier for mechanical protection may be useful. The devices are based on soluble zinc oxide nanoparticles mixed with the thermocleavable conjugated polymer poly-(3-(2-methylhexan-2-yl......A detailed description is given of the preparation of a polymer solar cell and its characterization. The solar cell can be prepared entirely in the ambient atmosphere by solution processing without the use of vacuum coating steps, and it can be operated in the ambient atmosphere with good...

  3. Cell-mediated immunity in operable bronchial carcinoma: the effect of injecting irradiated autologous tumour cells and BCG

    International Nuclear Information System (INIS)

    Stack, B.H.R.; McSwan, N.; Stirling, J.M.

    1979-01-01

    In 52 patients undergoing tests of cell-mediated immunity before surgical resection of bronchial carcinoma a positive tuberculin test result was found in 71% compared with 68% of age - and sex-matched controls. Sensitization to DNCB occurred in 52% of 37 patients but in 78% controls. There was depression of lymphocyte transformation by PPD in 19 patients compared with controls (p=0.001), but there was no difference in lymphocyte transformation by PHA pr pokeweed mitogen between 34 patients and controls. In a pilot study patients were randomly allocated to autograft (eight) or non-autograft (seven) groups. The autograft group were given an intradermal injection of a suspension of irradiated autologous tumour-cells mixed with intradermal BCG on the day of operation. Tests of cell-mediated immunity were repeated two weeks after operation. Five patients in each group received a course of radiotherapy to the mediastinum three weeks after operation. There was a rise in a cutaneous tuberculin reactivity (p=0.08) and total leucocyte count (p=0.09) in the autograft group postoperatively with a fall in total lymphocyte and T lymphocyte counts in the non-autograft group (p<0.05). These differences, however, were not followed by any difference in the frequency of tumour recurrence or the survival rate two years after operation. The results show that the immunological surveillance mechanism is impaired even in patients with early bronchial carcinoma and that it is possible to overcome postoperative immunological depression with specific immunotherapy combined with BCG. This treatment did not produce any clinical advantage in this small number of patients and the skin lesions caused the patients considerable discomfort. (author)

  4. Thermodynamic analysis of solid oxide fuel cell gas turbine systems operating with various biofuels

    Energy Technology Data Exchange (ETDEWEB)

    Patel, H.C.; Woudstra, T.; Aravind, P.V. [Process and Energy Laboratory, Delft University of Technology, Section Energy Technology, Leeghwaterstraat 44, 2628 CA Delft (Netherlands)

    2012-12-15

    Solid oxide fuel cell-gas turbine (SOFC-GT) systems provide a thermodynamically high efficiency alternative for power generation from biofuels. In this study biofuels namely methane, ethanol, methanol, hydrogen, and ammonia are evaluated exergetically with respect to their performance at system level and in system components like heat exchangers, fuel cell, gas turbine, combustor, compressor, and the stack. Further, the fuel cell losses are investigated in detail with respect to their dependence on operating parameters such as fuel utilization, Nernst voltage, etc. as well as fuel specific parameters like heat effects. It is found that the heat effects play a major role in setting up the flows in the system and hence, power levels attained in individual components. The per pass fuel utilization dictates the efficiency of the fuel cell itself, but the system efficiency is not entirely dependent on fuel cell efficiency alone, but depends on the split between the fuel cell and gas turbine powers which in turn depends highly on the nature of the fuel and its chemistry. Counter intuitively it is found that with recycle, the fuel cell efficiency of methane is less than that of hydrogen but the system efficiency of methane is higher. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Passively operated vapor-fed direct methanol fuel cells for portable applications

    Energy Technology Data Exchange (ETDEWEB)

    Eccarius, Steffen; Krause, Falko; Agert, Carsten [Fraunhofer Institute for Solar Energy Systems ISE, Department of Energy Systems, Heidenhofstrasse 2, 79110 Freiburg (Germany); Beard, Kevin [Department of Chemical Engineering, University of South Carolina, Columbia (United States)

    2008-08-01

    The impact of structural parameters and operating conditions has not been researched yet for vapor-fed operation of a DMFC at near-ambient conditions. Thus, a detailed parameter study that included reference cell measurements to assess anode and cathode losses separately was performed. Among other parameters like temperature or air stoichiometry, different opening ratios that controlled evaporation of methanol into the vapor chamber were examined. Water management was found to be a critical parameter for a vapor-fed DMFC. Depletion of water inside the anode catalyst layer, especially at higher current densities, decreased performance of the fuel cell substantially. Back diffusion of water from the cathode to the anode was examined. A micro-structured cathode electrode that increased water back diffusion due to a reduced mass transfer resistance was developed and investigated. Finally, efficiencies and heat losses of a vapor-fed DMFC were determined. (author)

  6. Residential care : Dutch and Italian residents of residential care facilities compared

    NARCIS (Netherlands)

    de Heer-Wunderink, Charlotte; Caro-Nienhuis, Annemarie D.; Sytema, Sjoerd; Wiersma, Durk

    2008-01-01

    Aims - Characteristics of patients living in residential care facilities and the availability of mental hospital- and residential beds in Italy and The Netherlands were compared to assess whether differences in the process of deinstitutionalisation have influenced the composition of their

  7. The relation between residential property and its surroundings and day- and night-time residential burglary

    NARCIS (Netherlands)

    Montoya, Lorena; Junger, Marianne; Ongena, Yfke

    This article examines how residential property and its surroundings influence day- and night-time residential burglary. Crime Prevention Through Environmental Design (CPTED) principles of territoriality, surveillance, access control, target hardening, image maintenance, and activity support underpin

  8. The Relation Between Residential Property and its Surroundings and Day- and Night-Time Residential Burglary

    NARCIS (Netherlands)

    Montoya, L.; Junger, Marianne; Ongena, Yfke

    This article examines how residential property and its surroundings influence day- and night-time residential burglary. Crime Prevention Through Environmental Design (CPTED) principles of territoriality, surveillance, access control, target hardening, image maintenance, and activity support underpin

  9. Ice formation in PEM fuel cells operated isothermally at sub-freezing temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Mukundan, Rangachary [Los Alamos National Laboratory; Luhan, Roger W [Los Alamos National Laboratory; Davey, John R [Los Alamos National Laboratory; Spendelow, Jacob S [Los Alamos National Laboratory; Borup, Rodney L [Los Alamos National Laboratory; Hussey, Daniel S [NIST; Jacobson, David L [NIST; Arif, Muhammad [NIST

    2009-01-01

    The effect of MEA and GDL structure and composition on the performance of single-PEM fuel cells operated isothermally at subfreezing temperatures is presented. The cell performance and durability are not only dependent on the MEA/GDL materials used but also on their interfaces. When a cell is operated isothermally at sub-freezing temperatures in constant current mode, the water formation due to the current density initially hydrates the membrane/ionomer and then forms ice in the catalyst layer/GDL. An increase in high frequency resistance was also observed in certain MEAs where there is a possibility of ice formation between the catalyst layer and GDL leading to a loss in contact area. The total water/ice holding capacity for any MEA was lower at lower temperatures and higher current densities. The durability of MEAs subjected to multiple isothermal starts was better for LANL prepared MEAs as compared to commercial MEAs, and cloth GDLs when compared to paper GDLs. The ice formation was monitored using high-resolution neutron radiography and was found to be concentrated near the cathode catalyst layer. However, there was significant ice formation in the GDLs especially at the higher temperature ({approx} -10 C) and lower current density (0.02 A/cm{sup 2}) operations. These results are consistent with the longer-term durability observations that show more severe degradation at the lower temperatures.

  10. Strategic optimisation of microgrid by evolving a unitised regenerative fuel cell system operational criterion

    Science.gov (United States)

    Bhansali, Gaurav; Singh, Bhanu Pratap; Kumar, Rajesh

    2016-09-01

    In this paper, the problem of microgrid optimisation with storage has been addressed in an unaccounted way rather than confining it to loss minimisation. Unitised regenerative fuel cell (URFC) systems have been studied and employed in microgrids to store energy and feed it back into the system when required. A value function-dependent on line losses, URFC system operational cost and stored energy at the end of the day are defined here. The function is highly complex, nonlinear and multi dimensional in nature. Therefore, heuristic optimisation techniques in combination with load flow analysis are used here to resolve the network and time domain complexity related with the problem. Particle swarm optimisation with the forward/backward sweep algorithm ensures optimal operation of microgrid thereby minimising the operational cost of the microgrid. Results are shown and are found to be consistently improving with evolution of the solution strategy.

  11. Study on component interface evolution of a solid oxide fuel cell stack after long term operation

    Science.gov (United States)

    Yang, Jiajun; Huang, Wei; Wang, Xiaochun; Li, Jun; Yan, Dong; Pu, Jian; Chi, Bo; Li, Jian

    2018-05-01

    A 5-cell solid oxide fuel cell (SOFC) stack with external manifold structure is assembled and underwent a durability test with an output of 250 W for nearly 4400 h when current density and operating temperature are 355 mA/cm2 and 750 °C. Cells used in the stack are anode-supported cells (ASC) with yttria-stabilized zirconia (YSZ) electrolytes, Ni/YSZ hydrogen electrodes, and YSZ based composite cathode. The dimension of the cell is 150 × 150 mm (active area: 130 × 130 mm). Ceramic-glass sealant is used in the stack to keep the gas tightness between cells, interconnects and manifolds. Pure hydrogen and dry air are used as fuel and oxidant respectively. The stack has a maximum output of 340 W at 562 mA/cm2 current density at 750 °C. The stack shows a degradation of 1.5% per 1000 h during the test with 2 thermal cycles to room temperature. After the test, the stack was dissembled and examined. The relationship between microstructure changes of interfaces and degradation in the stack are discussed. The microstructure evolution of interfaces between electrode, contact material and current collector are unveiled and their relationship with the degradation is discussed.

  12. Novel electrical energy storage system based on reversible solid oxide cells: System design and operating conditions

    Science.gov (United States)

    Wendel, C. H.; Kazempoor, P.; Braun, R. J.

    2015-02-01

    Electrical energy storage (EES) is an important component of the future electric grid. Given that no other widely available technology meets all the EES requirements, reversible (or regenerative) solid oxide cells (ReSOCs) working in both fuel cell (power producing) and electrolysis (fuel producing) modes are envisioned as a technology capable of providing highly efficient and cost-effective EES. However, there are still many challenges and questions from cell materials development to system level operation of ReSOCs that should be addressed before widespread application. This paper presents a novel system based on ReSOCs that employ a thermal management strategy of promoting exothermic methanation within the ReSOC cell-stack to provide thermal energy for the endothermic steam/CO2 electrolysis reactions during charging mode (fuel producing). This approach also serves to enhance the energy density of the stored gases. Modeling and parametric analysis of an energy storage concept is performed using a physically based ReSOC stack model coupled with thermodynamic system component models. Results indicate that roundtrip efficiencies greater than 70% can be achieved at intermediate stack temperature (680 °C) and elevated stack pressure (20 bar). The optimal operating condition arises from a tradeoff between stack efficiency and auxiliary power requirements from balance of plant hardware.

  13. Neutron radiography characterization of an operating proton exchange membrane fuel cell with localized current distribution measurements

    International Nuclear Information System (INIS)

    Gagliardo, J.J.; Owejan, J.P.; Trabold, T.A.; Tighe, T.W.

    2009-01-01

    Neutron radiography has proven to be a powerful tool to study and understand the effects of liquid water in an operating fuel cell. In the present work, this experimental method is coupled with locally resolved current and ohmic resistance measurements, giving additional insight into water management and fuel cell performance under a variety of conditions. The effects of varying the inlet humidification level and the current density of the 50 cm 2 cell are studied by simultaneously monitoring electrochemical performance with a 10x10 matrix of current sensors, and liquid water volumes are measured using the National Institute of Standards and Technology (NIST) neutron imaging facility. A counter flow, straight channel proton exchange membrane (PEM) fuel cell is used to demonstrate localized performance loss corresponds to water-filled channels that impede gas transport to the catalyst layer, thereby creating an area that has low current density. Furthermore, certain operating conditions causing excess water accumulation in the channels can result in localized proton resistance increase, a result that can only be accurately observed with combined radiography and distributed electrochemical measurements.

  14. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  15. Systematic investigation of the impact of operation conditions on the degradation behaviour of perovskite solar cells

    Science.gov (United States)

    Domanski, Konrad; Alharbi, Essa A.; Hagfeldt, Anders; Grätzel, Michael; Tress, Wolfgang

    2018-01-01

    Perovskite solar cells have achieved power-conversion efficiency values approaching those of established photovoltaic technologies, making the reliable assessment of their operational stability the next essential step towards commercialization. Although studies increasingly often involve a form of stability characterization, they are conducted in non-standardized ways, which yields data that are effectively incomparable. Furthermore, stability assessment of a novel material system with its own peculiarities might require an adjustment of common standards. Here, we investigate the effects of different environmental factors and electrical load on the ageing behaviour of perovskite solar cells. On this basis, we comment on our perceived relevance of the different ways these are currently aged. We also demonstrate how the results of the experiments can be distorted and how to avoid the common pitfalls. We hope this work will initiate discussion on how to age perovskite solar cells and facilitate the development of consensus stability measurement protocols.

  16. Experiment Based Teaching of Solar Cell Operation and Characterization Using the SolarLab Platform

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Kerekes, Tamas

    2014-01-01

    interfaces for exploring different solar cell principles and topics. The exercises presented in the current paper have been adapted from the original exercises developed for the SolarLab platform and are currently included in the Photovoltaic Power Systems courses (MSc and PhD level) taught at the Department...... which is a laboratory teaching tool developed at Transylvania University of Brasov. Using this platform, solar cells can be characterized under various illumination, temperature and angle of light incidence. Additionally, the SolarLab platform includes guided exercises and intuitive graphical user......Experiment based teaching methods are a great way to get students involved and interested in almost any topic. This paper presents such a hands-on approach for teaching solar cell operation principles along with characterization and modelling methods. This is achieved with the SolarLab platform...

  17. Small-Scale Low Cost Solid Oxide Fuel Cell Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    S. D. Vora

    2008-02-01

    Progress in tasks seeking greater cell power density and lower cost through new cell designs, new cell materials and lower operating temperature is summarized. The design of the program required Proof-of-Concept unit of residential capacity scale is reviewed along with a summary of results from its successful test. Attachment 1 summarizes the status of cell development. Attachment 2 summarizes the status of generator design, and Attachment 3 of BOP design.

  18. Residential cogeneration systems: review of the current technology

    International Nuclear Information System (INIS)

    Onovwiona, H.I.; Ugursal, V.I.

    2006-01-01

    There is a growing potential for the use of micro-cogeneration systems in the residential sector because they have the ability to produce both useful thermal energy and electricity from a single source of fuel such as oil or natural gas. In cogeneration systems, the efficiency of energy conversion increases to over 80% as compared to an average of 30-35% for conventional fossil fuel fired electricity generation systems. This increase in energy efficiency can result in lower costs and reduction in greenhouse gas emissions when compared to the conventional methods of generating heat and electricity separately. Cogeneration systems and equipment suitable for residential and small-scale commercial applications like hospitals, hotels or institutional buildings are available, and many new systems are under development. These products are used or aimed for meeting the electrical and thermal demands of a building for space and domestic hot water heating, and potentially, absorption cooling. The aim of this paper is to provide an up-to-date review of the various cogeneration technologies suitable for residential applications. The paper considers the various technologies available and under development for residential, i.e. single-family ( e ) and multi-family (10-30kW t ) applications, with focus on single-family applications. Technologies suitable for residential cogeneration systems include reciprocating internal combustion engine, micro-turbine, fuel cell, and reciprocating external combustion Stirling engine based cogeneration systems. The paper discusses the state of development and the performance, environmental benefits, and costs of these technologies. (author)

  19. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    Science.gov (United States)

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in

  20. Thermal Modeling and Management of Solid Oxide Fuel Cells Operating with Internally Reformed Methane

    Science.gov (United States)

    Wu, Yiyang; Shi, Yixiang; Cai, Ningsheng; Ni, Meng

    2018-06-01

    A detailed three-dimensional mechanistic model of a large-scale solid oxide fuel cell (SOFC) unit running on partially pre-reformed methane is developed. The model considers the coupling effects of chemical and electrochemical reactions, mass transport, momentum and heat transfer in the SOFC unit. After model validation, parametric simulations are conducted to investigate how the methane pre-reforming ratio affects the transport and electrochemistry of the SOFC unit. It is found that the methane steam reforming reaction has a "smoothing effect", which can achieve more uniform distributions of gas compositions, current density and temperature among the cell plane. In the case of 1500 W/m2 power density output, adding 20% methane absorbs 50% of internal heat production inside the cell, reduces the maximum temperature difference inside the cell from 70 K to 22 K and reduces the cathode air supply by 75%, compared to the condition of completely pre-reforming of methane. Under specific operating conditions, the pre-reforming ratio of methane has an optimal range for obtaining a good temperature distribution and good cell performance.

  1. Innovative anode materials and architectured cells for high temperature steam electrolysis operation

    International Nuclear Information System (INIS)

    Ogier, Tiphaine

    2012-01-01

    In order to improve the electrochemical performances of cells for high temperature steam electrolysis (HTSE), innovative oxygen electrode materials have been studied. The compounds Ln_2NiO_4_+_δ (Ln = La, Pr or Nd), Pr_4Ni_3O_1_0_±_δ and La_0_,_6S_r0_,_4Fe_0_,_8Co_0_,_2O_3_-_δ have been selected for their mixed electronic and ionic conductivity. First, their physical and chemical properties have been investigated. Then, the electrodes were shaped on symmetrical half cells,adding a thin ceria-based interlayer between the electrode and the yttria doped zirconia-based electrolyte. These architectured cells lead to low polarization resistances (RP≤ 0.1 Ω.cm"2 at 800 C) as well as reduced anodic over potentials. An electrochemical model has been developed in order to describe and analyze the experimental polarization curves.The electrode with the lower overpotential, i.e. Pr_2NiO_4_+δ, has been selected and characterized into complete cermet-supported cells. Under HTSE operation, at 800 C, a high current density was measured, close to i = -0.9 A.cm"-"2 for a cell voltage equals to 1.3 V, the conversion rate being about 60%. (author) [fr

  2. The quality of life in residential areas : an introduction to a film made by the Foundation for Film and Science, in co-operation with the Institute for Road Safety Research SWOV, supported by the Royal Dutch Touring Club ANWB. Paper presented at the 13th AIT/FIA/PIARC International Study Week on Traffic Engineering and Safety, Montreux, 11-16 September 1978.

    NARCIS (Netherlands)

    1978-01-01

    The films purpose is to review what is known about housing-quality social activities and road safety. These aspects constitute the so-called quality of life in residential areas. The possible influence is examined of several principles of urban planning on the quality of life in residential areas.

  3. Store-operated Ca{sup 2+} entry in rhabdomyosarcoma cells

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Evi, E-mail: Evi.Schmid@med.uni-tuebingen.de [Department of Pediatric Surgery & Pediatric Urology, Eberhard-Karls-University, Hoppe-Seyler Straße 3, 72076, Tuebingen (Germany); Stagno, Matias Julian [Department of Pediatric Surgery & Pediatric Urology, Eberhard-Karls-University, Hoppe-Seyler Straße 3, 72076, Tuebingen (Germany); Yan, Jing [Department of Cardiology & Vascular Medicine and Physiology, Eberhard-Karls-University, Gmelinstr.5/Otfried-Mueller-Str.10, 72076, Tuebingen (Germany); Stournaras, Christos [Department of Biochemistry, University of Crete Medical School, GR-71003, Heraklion, Crete (Greece); Lang, Florian [Department of Cardiology & Vascular Medicine and Physiology, Eberhard-Karls-University, Gmelinstr.5/Otfried-Mueller-Str.10, 72076, Tuebingen (Germany); Fuchs, Jörg [Department of Pediatric Surgery & Pediatric Urology, Eberhard-Karls-University, Hoppe-Seyler Straße 3, 72076, Tuebingen (Germany); Seitz, Guido [Department of Pediatric Surgery & Pediatric Urology, Eberhard-Karls-University, Hoppe-Seyler Straße 3, 72076, Tuebingen (Germany); Department of Pediatric Surgery, University Hospital Marburg, Marburg (Germany)

    2016-08-12

    Rhabdomyosarcoma (RMS), the most common pediatric soft tissue sarcoma, has an intrinsic or early-acquisition of resistance to chemo- and radiation therapy. Molecular determinants pivotal for RMS migration, metastatic invasion, cell proliferation, and survival are incompletely identified. Migration and cell proliferation were shown to correlate with cytosolic Ca{sup 2+} activity ([Ca{sup 2+}]{sub i}). Store-operated Ca{sup 2+}-entry (SOCE) that increases intracellular [Ca{sup 2+}] is accomplished by Orai1, a pore-forming ion channel unit, the expression of which is stimulated by the transcription factor NFκB. The present study explored the expression of Orai1 and its regulators STIM1 and NFκB in human rhabdomyosarcoma cell lines and analyzed their impact on cell proliferation and migration. For the study human rhabdomyosarcoma cell lines RD (embryonal) and RH30 (alveolar) were analyzed for Orai1, STIM1, and NFκB transcription by RT-PCR and their corresponding proteins in Western blot. [Ca{sup 2+}]{sub i} was detected via Fura-2 fluorescence and SOCE – resulting from [Ca{sup 2+}]{sub i} increase following store depletion with extracellular Ca{sup 2+} removal and inhibition of the sarcoendoplasmatic reticular Ca{sup 2+} ATPase – detected with thapsigargin. Cell migration was analyzed in transwell and mitotic cell death with the clonogenic assay. In summary, Orai1, STIM1, and NFκB are expressed in embryonal (RD) and alveolar (RH30) rhabdomyosarcoma. SOCE inhibitor BTP2, Orai1 inhibitor 2-APB, or NFκB inhibitor wogonin virtually abrogated (BTP2, 2-APB) or significantly reduced (wogonin) SOCE. Moreover, SOCE inhibitors 2-APB and BTP2 and wogonin significantly inhibited migration and proliferation of both, RD and RH30 cells. These results suggest that Orai1 signaling is involved in SOCE into rhabdomyosarcoma cells thus contributing to migration, invasion and proliferation. - Highlights: • Orai1, STIM1, and NFκB are expressed in RD and RH30 rhabdomyosarcoma

  4. Composite polymer membranes for proton exchange membrane fuel cells operating at elevated temperatures and reduced humidities

    Science.gov (United States)

    Zhang, Tao

    Proton Exchange Membrane Fuel Cells (PEMFCs) are the leading candidate in the fuel cell technology due to the high power density, solid electrolyte, and low operational temperature. However, PEMFCs operating in the normal temperature range (60-80°C) face problems including poor carbon monoxide tolerance and heat rejection. The poisoning effect can be significantly relieved by operating the fuel cell at elevated temperature, which also improves the heat rejection and electrochemical kinetics. Low relative humidity (RH) operation is also desirable to simplify the reactant humidification system. However, at elevated temperatures, reduced RH PEMFC performance is seriously impaired due to irreversible water loss from presently employed state-of-the-art polymer membrane, Nafion. This thesis focuses on developing polymer electrolyte membranes with high water retention ability for operation in elevated temperature (110-150°C), reduced humidity (˜50%RH) PEMFCs. One approach is to alter Nafion by adding inorganic particles such as TiO2, SiO2, Zr(HPO 4)2, etc. While the presence of these materials in Nafion has proven beneficial, a reduction or no improvement in the PEMFC performance of Nafion/TiO2 and Nafion/Zr(HPO4)2 membranes is observed with reduced particle sizes or increased particle loadings in Nafion. It is concluded that the PEMFC performance enhancement associated with addition of these inorganic particles was not due to the particle hydrophilicity. Rather, the particle, partially located in the hydrophobic region of the membrane, benefits the cell performance by altering the membrane structure. Water transport properties of some Nafion composite membranes were investigated by NMR methods including pulsed field gradient spin echo diffusion, spin-lattice relaxation, and spectral measurements. Compared to unmodified Nafion, composite membranes materials exhibit longer longitudinal relaxation time constant T1. In addition to the Nafion material, sulfonated styrene

  5. An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings

    International Nuclear Information System (INIS)

    Lai, A.C.K.; Mui, K.W.; Wong, L.T.; Law, L.Y.

    2009-01-01

    The indoor environmental quality (IEQ) in residential buildings is examined from the prospect of an occupant's acceptance in four aspects: thermal comfort, indoor air quality, noise level and illumination level. Based on the evaluations by 125 occupants living in 32 typical residential apartments in Hong Kong, this study proposes empirical expressions to approximate the overall IEQ acceptance with respect to four contributors, namely operative temperature, carbon dioxide concentration, equivalent noise level and illumination level, via a multivariate logistic regression model. A range of IEQ acceptances for regular residential conditions is determined and the dependence of the predicted overall IEQ acceptance on the variations of the contributors is discussed. The proposed overall IEQ acceptance can be used as a quantitative assessment criterion for similar residential environments where an occupant's evaluation is expected. (author)

  6. A culture of education: Enhancing school performance of youth living in residential group care in Ontario.

    Science.gov (United States)

    Gharabaghi, Kiaras

    2011-01-01

    This article presents a synthesis of what is known about the educational experiences of youth living in residential group care based on a literature review that highlights both the experiences of the youth themselves and the operational context of residential group care in Ontario as it pertains to educational performance. The author argues that there is little emphasis on education within the residential group care sector in Ontario that could translate into more productive educational experiences for youth. The article then provides a framework for developing a culture of education for residential group care that can be acted upon expeditiously. Enhancing the educational performance of young people living in group care will require a cultural approach that provides for daily and pervasive education supports and encouragement, and aims to enhance the lived experience of young people pursuant to their education.

  7. Optimal Scheduling of Residential Microgrids Considering Virtual Energy Storage System

    Directory of Open Access Journals (Sweden)

    Weiliang Liu

    2018-04-01

    Full Text Available The increasingly complex residential microgrids (r-microgrid consisting of renewable generation, energy storage systems, and residential buildings require a more intelligent scheduling method. Firstly, aiming at the radiant floor heating/cooling system widely utilized in residential buildings, the mathematical relationship between the operative temperature and heating/cooling demand is established based on the equivalent thermodynamic parameters (ETP model, by which the thermal storage capacity is analyzed. Secondly, the radiant floor heating/cooling system is treated as virtual energy storage system (VESS, and an optimization model based on mixed-integer nonlinear programming (MINLP for r-microgrid scheduling is established which takes thermal comfort level and economy as the optimization objectives. Finally, the optimal scheduling results of two typical r-microgrids are analyzed. Case studies demonstrate that the proposed scheduling method can effectively employ the thermal storage capacity of radiant floor heating/cooling system, thus lowering the operating cost of the r-microgrid effectively while ensuring the thermal comfort level of users.

  8. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  9. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  10. PEM fuel cells operated at 0% relative humidity in the temperature range of 23-120 oC

    International Nuclear Information System (INIS)

    Zhang, Jianlu; Tang, Yanghua; Song, Chaojie; Cheng, Xuan; Zhang, Jiujun; Wang, Haijiang

    2007-01-01

    Operation of a proton exchange membrane (PEM) fuel cell without external humidification (or 0% relative humidity, abbreviated as 0% RH) of the reactant gases is highly desirable, because it can eliminate the gas humidification system and thus decrease the complexity of the PEM fuel cell system and increase the system volume power density (W/l) and weight power density (W/kg). In this investigation, a PEM fuel cell was operated in the temperature range of 23-120 o C, in particular in a high temperature PEM fuel cell operation range of 80-120 o C, with dry reactant gases, and the cell performance was examined according to varying operation parameters. An ac impedance method was used to compare the performance at 0% RH with that at 100% RH; the results suggested that the limited proton transfer process to the Pt catalysts, mainly in the inonomer within the membrane electrode assembly (MEA) could be responsible for the performance drop. It was demonstrated that operating a fuel cell using a commercially available membrane (Nafion (registered) 112) is feasible under certain conditions without external humidification. However, the cell performance at 0% RH decreased with increasing operation temperature and reactant gas flow rate and decreasing operation pressure

  11. Numerical simulation of proton exchange membrane fuel cells at high operating temperature

    Science.gov (United States)

    Peng, Jie; Lee, Seung Jae

    A three-dimensional, single-phase, non-isothermal numerical model for proton exchange membrane (PEM) fuel cell at high operating temperature (T ≥ 393 K) was developed and implemented into a computational fluid dynamic (CFD) code. The model accounts for convective and diffusive transport and allows predicting the concentration of species. The heat generated from electrochemical reactions, entropic heat and ohmic heat arising from the electrolyte ionic resistance were considered. The heat transport model was coupled with the electrochemical and mass transport models. The product water was assumed to be vaporous and treated as ideal gas. Water transportation across the membrane was ignored because of its low water electro-osmosis drag force in the polymer polybenzimidazole (PBI) membrane. The results show that the thermal effects strongly affect the fuel cell performance. The current density increases with the increasing of operating temperature. In addition, numerical prediction reveals that the width and distribution of gas channel and current collector land area are key optimization parameters for the cell performance improvement.

  12. Numerical simulation of proton exchange membrane fuel cells at high operating temperature

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Jie; Lee, Seung Jae [Energy Lab, Samsung Advanced Institute of Technology, Mt. 14-1 Nongseo-Dong, Giheung-Gu, Yongin-Si, Gyeonggi-Do 446-712 (Korea, Republic of)

    2006-11-22

    A three-dimensional, single-phase, non-isothermal numerical model for proton exchange membrane (PEM) fuel cell at high operating temperature (T>=393K) was developed and implemented into a computational fluid dynamic (CFD) code. The model accounts for convective and diffusive transport and allows predicting the concentration of species. The heat generated from electrochemical reactions, entropic heat and ohmic heat arising from the electrolyte ionic resistance were considered. The heat transport model was coupled with the electrochemical and mass transport models. The product water was assumed to be vaporous and treated as ideal gas. Water transportation across the membrane was ignored because of its low water electro-osmosis drag force in the polymer polybenzimidazole (PBI) membrane. The results show that the thermal effects strongly affect the fuel cell performance. The current density increases with the increasing of operating temperature. In addition, numerical prediction reveals that the width and distribution of gas channel and current collector land area are key optimization parameters for the cell performance improvement. (author)

  13. Integration of motor traffic in residential areas.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1977-01-01

    In stead of banning the cars from residential areas, the plan is to integrate them in such a way that they can still be used, but that they will loose their predominant position. The areas where this integration is to take place are called residential yards. This paper concentrates on the lighting

  14. Mitigating residential exposure to secondhand tobacco smoke

    Science.gov (United States)

    Klepeis, Neil E.; Nazaroff, William W.

    In a companion paper, we used a simulation model to explore secondhand tobacco smoke (SHS) exposures for typical conditions in residences. In the current paper, we extend this analysis to evaluate the effectiveness of physical mitigation approaches in reducing nonsmokers' exposure to airborne SHS particulate matter in a hypothetical 6-zone house. Measures investigated included closing doors or opening windows in response to smoking activity, modifying location patterns to segregate the nonsmoker and the active smoker, and operating particle filtration devices. We first performed 24 scripted simulation trials using hypothetical patterns of occupant location. We then performed cohort simulation trials across 25 mitigation scenarios using over 1000 pairs of nonsmoker and smoker time-location patterns that were selected from a survey of human activity patterns in US homes. We limited cohort pairs to cases where more than 10 cigarettes were smoked indoors at home each day and the nonsmoker was at home for more than two thirds of the day. We evaluated the effectiveness of each mitigation approach by examining its impact on the simulated frequency distribution of residential SHS particle exposure. The two most effective strategies were the isolation of the smoker in a closed room with an open window, and a ban on smoking whenever the nonsmoker was at home. The use of open windows to supply local or cross ventilation, or the operation of portable filtration devices in smoking rooms, provided moderate exposure reductions. Closed doors, by themselves, were not effective.

  15. Therapeutic Residential Care for Children and Youth:

    DEFF Research Database (Denmark)

    Whittaker, James K.; Holmes, Lisa; del Valle, Jorge F.

    2016-01-01

    so in closer collaboration with their families and in closer proximity to their home communities; and, (3) with the hope of reducing the high costs often associated with group residential provision. In some jurisdictions, efforts to reduce residential care resources in the absence of sufficient...... alternatives to serve high-resource needing youth has had unintended and negative consequences. It is within this context that a working group international experts representing research, policy, service delivery and families (International Work Group for Therapeutic Residential Care) convened at the Centre...... for Child and Family Research, Loughborough University in the U.K. for a Summit meeting on therapeutic residential care for children and youth funded by the Sir Halley Stewart Trust (UK). The focus centered on what is known about therapeutic residential care and what key questions should inform a priority...

  16. [Analysis of the Effect of Non-phacoemulsification Cataract Operation on Corneal Endothelial Cell Nucleus Division].

    Science.gov (United States)

    Huang, Zufeng; Miao, Xiaoqing

    2015-09-01

    To investigate the effect of non-phacoemulsification cataract operation in two different patterns of nucleus delivery on the quantity and morphology of corneal endothelial cells and postoperative visual acuity. Forty patients diagnosed with cataract underwent cataract surgery and were assigned into the direct nuclear delivery and semi-nuclear delivery groups. Lens density was measured and divided into the hard and soft lenses according to Emery-little lens nucleus grading system. Non-phacoemulsification cataract operation was performed. At 3 d after surgery, the quantity and morphology of corneal endothelium were counted and observed under corneal endothelial microscope. During 3-month postoperative follow-up, the endothelial cell loss rate, morphological changes and visual acuity were compared among four groups. Corneal endothelial cell loss rate in the direct delivery of hard nucleus group significantly differed from those in the other three groups before and 3 months after operation (P nucleus, semi-delivery of hard nucleus and semi-delivery soft nucleus groups (all P > 0.05). Preoperative and postoperative 2-d visual acuity did not differ between the semi-delivery of hard nucleus and direct delivery of soft nucleus groups (P = 0.49), significantly differed from those in the semi-delivery of soft nucleus (P = 0.03) and direct delivery of hard nucleus groups (P = 0.14). Visual acuity at postoperative four months did not differ among four groups (P = 0.067). During non-phacoemulsification cataract surgery, direct delivery of hard nucleus caused severe injury to corneal endothelium and semi-delivery of soft nucleus yielded mild corneal endothelial injury. Slight corneal endothelial injury exerted no apparent effect upon visual acuity and corneal endothelial morphology at three months after surgery.

  17. Preliminary evaluation of rotational Vol-oxidizer for hot cell operation - 5320

    International Nuclear Information System (INIS)

    Kim, Y.H.; Lee, J.W.; Cho, Y.Z.; Ahn, D.H.; Song, K.C.

    2015-01-01

    KAERI is developing a mechanical head-end process for pyro-processing. As a piece of the processing equipment, a vol-oxidizer that can handle several tens of kg of HM/batch is under development to supply U 3 O 8 powders to an electrolytic reduction (ER) reactor. To operate a vol-oxidizer in a hot cell, the reactor should be optimized by the mechanical design, and the vol-oxidizer should have a high hull recovery rate. In addition, a vol-oxidizer for hot cell demonstrations that handles the spent fuel of high radiation virulence in a limited space should have a small size and not scatter in its outlet. In this paper, we aim at a preliminary evaluation of a rotational vol-oxidizer for hot cell operation. To evaluate the preliminary situation, we produced a theoretical equation of an optimum reactor size, and verification tests were conducted using an acryl vessel and zircaloy-4 tube according to various weights and lengths. In addition, we predicted the terminal velocity of U 3 O 8 using the terminal velocity of SiO 2 , which will determine the optimum air flux, and through an oxidation experiment, we verified the theory form to detect the existence of U 3 O 8 powder in a discharge filter. In addition, hull separation tests were conducted using a reactor and hulls with a 50 kg HM/batch for the recovery rate of the hulls. The results indicate that we obtained an appropriate air flux so as to not cause U 3 O 8 powder dispersion from using a Stokes equation and density ratio equation prior to the demonstration. The optimum flow and experimental results of the hull separation test have been applied for the design of the demonstration oxidizer, and the operation conditions of the oxidizer were produced. (authors)

  18. A practical algorithm for optimal operation management of distribution network including fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, Taher; Meymand, Hamed Zeinoddini; Nayeripour, Majid [Electrical and Electronic Engineering Department, Shiraz University of Technology, Shiraz (Iran)

    2010-08-15

    Fuel cell power plants (FCPPs) have been taken into a great deal of consideration in recent years. The continuing growth of the power demand together with environmental constraints is increasing interest to use FCPPs in power system. Since FCPPs are usually connected to distribution network, the effect of FCPPs on distribution network is more than other sections of power system. One of the most important issues in distribution networks is optimal operation management (OOM) which can be affected by FCPPs. This paper proposes a new approach for optimal operation management of distribution networks including FCCPs. In the article, we consider the total electrical energy losses, the total electrical energy cost and the total emission as the objective functions which should be minimized. Whereas the optimal operation in distribution networks has a nonlinear mixed integer optimization problem, the optimal solution could be obtained through an evolutionary method. We use a new evolutionary algorithm based on Fuzzy Adaptive Particle Swarm Optimization (FAPSO) to solve the optimal operation problem and compare this method with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Differential Evolution (DE), Ant Colony Optimization (ACO) and Tabu Search (TS) over two distribution test feeders. (author)

  19. False Operation of Static Random Access Memory Cells under Alternating Current Power Supply Voltage Variation

    Science.gov (United States)

    Sawada, Takuya; Takata, Hidehiro; Nii, Koji; Nagata, Makoto

    2013-04-01

    Static random access memory (SRAM) cores exhibit susceptibility against power supply voltage variation. False operation is investigated among SRAM cells under sinusoidal voltage variation on power lines introduced by direct RF power injection. A standard SRAM core of 16 kbyte in a 90 nm 1.5 V technology is diagnosed with built-in self test and on-die noise monitor techniques. The sensitivity of bit error rate is shown to be high against the frequency of injected voltage variation, while it is not greatly influenced by the difference in frequency and phase against SRAM clocking. It is also observed that the distribution of false bits is substantially random in a cell array.

  20. Direct ethanol solid oxide fuel cell operating in gradual internal reforming

    Science.gov (United States)

    Nobrega, S. D.; Galesco, M. V.; Girona, K.; de Florio, D. Z.; Steil, M. C.; Georges, S.; Fonseca, F. C.

    2012-09-01

    An electrolyte supported solid oxide fuel cell (SOFC) using standard electrodes, doped-lanthanum manganite cathode and Ni-cermet anode, was operated with direct (anhydrous) ethanol for more than 100 h, delivering essentially the same power output as running on hydrogen. A ceria-based layer provides the catalytic activity for the gradual internal reforming, which uses the steam formed by the electrochemical oxidation of hydrogen for the decomposition of ethanol. Such a concept opens up the way for multi-fuel SOFCs using standard components and a catalytic layer.

  1. Thin film photovoltaic cells having increased durability and operating life and method for making same

    Science.gov (United States)

    Barnett, Allen M.; Masi, James V.; Hall, Robert B.

    1980-12-16

    A solar cell having a copper-bearing absorber is provided with a composite transparent encapsulating layer specifically designed to prevent oxidation of the copper sulfide. In a preferred embodiment, the absorber is a layer of copper sulfide and the composite layer comprises a thin layer of copper oxide formed on the copper sulfide and a layer of encapsulating glass formed on the oxide. It is anticipated that such devices, when exposed to normal operating conditions of various terrestrial applications, can be maintained at energy conversion efficiencies greater than one-half the original conversion efficiency for periods as long as thirty years.

  2. Spectral resolution control of acousto-optical cells operating with collimated and divergent beams

    Science.gov (United States)

    Voloshinov, Vitaly B.; Mishin, Dimitry D.

    1994-01-01

    The paper is devoted to theoretical and experimental investigations of acousto-optical interactions in crystals which may be used for spectral filtration of light in tunable acousto- optical filters. Attention is paid to spectral resolution control during operation with divergent or collimated noncoherent optical beams. In all examined cases spectral bands of anisotropic Bragg diffraction were regulated by means of novel electronical methods. Resolution control was achieved in paratellurite cells with non-collinear and quasi-collinear regimes of the diffraction. Filtration spectral bandwidths for visible light were electronically changed by a factor of 10 divided by 20 by drive electrical signals switching and drive electrical power regulations.

  3. Modification of a scanning electron microscope for remote operation in a hot cell

    International Nuclear Information System (INIS)

    Reed, J.R.; Watson, H.E.; Smidt, F.A. Jr.

    1982-01-01

    Scanning electron microscopy (SEM) examination of broken fracture specimens is an essential part of the characterization of the failure mode of fracture toughness of specimens. The large specimen mass required for such examinations dictates the use of a shielded facility for performing such examinations on irradiated specimens. This report describes the modification of a commercial SEM for remote operation in a hot cell. The facility is used to examine specimens from several Navy and DOE-sponsored programs conducted at NRL which require the examination of radioactive materials

  4. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads

  5. Degradation Mechanism in a Direct Carbon Fuel Cell Operated with Demineralised Brown Coal

    International Nuclear Information System (INIS)

    Rady, Adam C.; Giddey, Sarbjit; Kulkarni, Aniruddha; Badwal, Sukhvinder P.S.; Bhattacharya, Sankar

    2014-01-01

    Graphical abstract: - Highlights: • Degradation mechanism studied for demineralised coal in a direct carbon fuel cell. • Diffusion limited processes dominate the electrode polarisation losses in pure N 2 . • Major fuel cell performance loss occurred due to loss of carbon/anode contacts. • The anode retained its phase structure with minor other phases formed in operation. - Abstract: The performance of a demineralised and devolatilised coal from the Morwell mine in the Latrobe Valley, Victoria, has been investigated in a direct carbon fuel cell (DCFC) operated at 850 °C. The focus of the investigation has been on understanding degradation issues as a function of time involving a sequence of electrochemical impedance spectroscopy and voltage-current characteristic. Diffusion limited processes dominate the electrode polarisation losses in pure N 2 atmosphere, however, these decrease substantially in the presence of CO 2 as the anode chamber purge gas, due to in situ generation of fuel species by the reaction of CO 2 with carbon. Post-mortem analysis of anode by SEM and XRD revealed only a minor degradation due to its reduction, particle agglomeration as well as the formation of small quantity of new phases. However, major fuel cell performance degradation (increase of ohmic resistive and electrode polarisation losses) occurred due to loss of carbon/anode contacts and a reduction in the electron-conducting pathways as the fuel was consumed. The investigations revealed that the demineralised coal char can be used as a viable fuel for DCFC, however, further developments on anode materials and fuel feed mechanism would be required to achieve long-term sustained performance

  6. Generation model of positional values as cell operation during the development of multicellular organisms.

    Science.gov (United States)

    Ogawa, Ken-ichiro; Miyake, Yoshihiro

    2011-03-01

    Many conventional models have used the positional information hypothesis to explain each elementary process of morphogenesis during the development of multicellular organisms. Their models assume that the steady concentration patterns of morphogens formed in an extracellular environment have an important property of positional information, so-called "robustness". However, recent experiments reported that a steady morphogen pattern, the concentration gradient of the Bicoid protein, during early Drosophila embryonic development is not robust for embryo-to-embryo variability. These reports encourage a reconsideration of a long-standing problem in systematic cell differentiation: what is the entity of positional information for cells? And, what is the origin of the robust boundary of gene expression? To address these problems at a cellular level, in this article we pay attention to the re-generative phenomena that show another important property of positional information, "size invariance". In view of regenerative phenomena, we propose a new mathematical model to describe the generation mechanism of a spatial pattern of positional values. In this model, the positional values are defined as the values into which differentiable cells transform a spatial pattern providing positional information. The model is mathematically described as an associative algebra composed of various terms, each of which is the multiplication of some fundamental operators under the assumption that the operators are derived from the remarkable properties of cell differentiation on an amputation surface in regenerative phenomena. We apply this model to the concentration pattern of the Bicoid protein during the anterior-posterior axis formation in Drosophila, and consider the conditions needed to establish the robust boundary of the expression of the hunchback gene. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Optimised fuel cell operation management. Final report; Optimiertes Betriebsmanagement von Brennstoffzellen. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-11-05

    Investigations were carried out on two fuel cell systems of the type ONSI PC 25C (large fuel cells) and three fuel cell heaters of the type HXS 1000 PREMIERE by Sulzer HEXIS (small fuel cells) for long periods of time and in different modes of operation. Information was obtained on efficiencies and performance, pollutant emissions, degradation and availability. The status of the project is reported and compared with the goals stated initially. (orig.) [German] Das Hauptziel des Projektes bestand darin, Kriterien fuer den optimalen Betrieb (hohe Verfuegbarkeit, geringe Anzahl von Abschaltungen, hohe Energienutzung etc.) von Brennstoffzellen im Zusammenspiel mit den peripheren Komponenten der Gebaeudetechnik zu ermitteln. Hierzu wurden Untersuchungen an zwei Brennstoffzellen-Anlagen vom Typ ONSI PC 25C (grosse BZ) und an drei Brennstoffzellen-Heizgeraeten HXS 1000 PREMIERE von Sulzer HEXIS (kleine BZ) ueber laengere Zeitraeume und bei weitestgehend unterschiedlichen Betriebsweisen durchgefuehrt. In Auswertung dieser Messkomplexe wurden Aussagen zum Betriebsverhalten der Brennstoffzellen, wie z.B. zu Wirk- und Nutzungsgraden, Schadstoffemissionen, Verlauf der Degradation sowie zur Verfuegbarkeit getroffen. Im vorliegenden Bericht wird der erreichte Sachstand detailliert dargestellt und mit den Zielsetzungen des FuE-Antrages verglichen. (orig.)

  8. Optimizing solid oxide fuel cell cathode processing route for intermediate temperature operation

    DEFF Research Database (Denmark)

    Ortiz-Vitoriano, N.; Bernuy-Lopez, Carlos; Ruiz de Larramendi, I.

    2013-01-01

    -priced raw material and cost-effective production techniques.In this work the perovskite-type La0.6Ca0.4Fe0.8Ni0.2O3 (LCFN) oxide has been used in order to optimize intermediate temperature SOFC cathode processing route. The advantages this material presents arise from the low temperature powder calcination......For Solid Oxide Fuel Cells (SOFCs) to become an economically attractive energy conversion technology suitable materials which allow operation at lower temperatures, while retaining cell performance, must be developed. At the same time, the cell components must be inexpensive - requiring both low...... (∼600°C) and electrode sintering (∼800°C) of LCFN electrodes, making them a cheaper alternative to conventional SOFC cathodes. An electrode polarization resistance as low as 0.10Ωcm2 at 800°C is reported, as determined by impedance spectroscopy studies of symmetrical cells sintered at a range...

  9. Special considerations on operating a fuel cell power plant using natural gas with marginal heating value

    Energy Technology Data Exchange (ETDEWEB)

    Moses, L. Ng; Chien-Liang Lin [Industrial Technology Research Institute, Taiwan (China); Ya-Tang Cheng [Power Research Institute, Taiwan (China)

    1996-12-31

    In realizing new power generation technologies in Taiwan, a phosphoric acid fuel cell power plant (model PC2513, ONSI Corporation) has been installed in the premises of the Power Research Institute of the Taiwan Power Company in Taipei County of Taiwan. The pipeline gas supplying to the site of this power plant has a high percentage of carbon dioxide and thus a slightly lower heating value than that specified by the manufacturer. Because of the lowering of heating value of input gas, the highest Output power from the power plant is understandably less than the rated power of 200 kW designed. Further, the transient response of the power plant as interrupted from the Grid is also affected. Since this gas is also the pipeline gas supplying to the heavily populated Taipei Municipal area, it is conceivable that the success of the operations of fuel cells using this fuel is of vital importance to the promotion of the use of this power generation technology in Taiwan. Hence, experiments were set up to assess the feasibility of this fuel cell power plant using the existing pipeline gas in this part of Taiwan where fuel cells would most likely find useful.

  10. Hydrogen production from formic acid in pH-stat fed-batch operation for direct supply to fuel cell.

    Science.gov (United States)

    Shin, Jong-Hwan; Yoon, Jong Hyun; Lee, Seung Hoon; Park, Tai Hyun

    2010-01-01

    Enterobacter asburiae SNU-1 harvested after cultivation was used as a whole cell biocatalyst, for the production of hydrogen. Formic acid was efficiently converted to hydrogen using the harvested cells with an initial hydrogen production rate and total hydrogen production of 491 ml/l/h and 6668 ml/l, respectively, when 1 g/l of whole cell enzyme was used. Moreover, new pH-stat fed-batch operation was conducted, and total hydrogen production was 1.4 times higher than that of batch operation. For practical application, bio-hydrogen produced from formic acid using harvested cells was directly applied to PEMFC for power generation.

  11. Operating experience with a 250 kW el molten carbonate fuel cell (MCFC) power plant

    Science.gov (United States)

    Bischoff, Manfred; Huppmann, Gerhard

    The MTU MCFC program is carried out by a European consortium comprising the German companies MTU Friedrichshafen GmbH, Ruhrgas AG and RWE Energie AG as well as the Danish company Energi E2 S/A. MTU acts as consortium leader. The company shares a license and technology exchange agreement with Fuel Cell Energy Inc., Danbury, CT, USA (formerly Energy Research Corp., ERC). The program was started in 1990 and covers a period of about 10 years. The highlights of this program to date are: Considerable improvements regarding component stability have been demonstrated on laboratory scale. Manufacturing technology has been developed to a point which enables the consortium to fabricate the porous components on a 250 cm 2 scale. Several large area stacks with 5000-7660 cm 2 cell area and a power range of 3-10 kW have been tested at the facilities in Munich (Germany) and Kyndby (Denmark). These stacks have been supplied by FCE. As far as the system design is concerned it was soon realized that conventional systems do not hold the promise for competitive power plants. A system analysis led to the conclusion that a new innovative design approach is required. As a result the "Hot Module" system was developed by the consortium. A Hot Module combines all the components of a MCFC system operating at the similar temperatures and pressures into a common thermally insulated vessel. In August 1997 the consortium started its first full size Hot Module MCFC test plant at the facilities of Ruhrgas AG in Dorsten, Germany. The stack was assembled in Munich using 292 cell packages purchased from FCE. The plant is based on the consortium's unique and proprietary "Hot Module" concept. It operates on pipeline natural gas and was grid connected on 16 August 1997. After a total of 1500 h of operation, the plant was intentionally shut down in a controlled manner in April 1998 for post-test analysis. The Hot Module system concept has demonstrated its functionality. The safety concept has been

  12. Pre-operative concurrent chemoradiotherapy for stage IIIA (N2) Non-Small cell lung cancer

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Ahn, Yong Chan; Park, Keun Chil

    1999-01-01

    This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45-67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in 12, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal lymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intraventous cis-Platin (100 mg/m 2 ) on day 1 and oral Etoposide (50 mg/m 2 /day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred in 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/13) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative tumor

  13. Pre-operative concurrent chemoradiotherapy for stage IIIA (N2) Non-Small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyu Chan; Ahn, Yong Chan; Park, Keun Chil [College of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)] [and others

    1999-06-01

    This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45-67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in 12, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal lymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intraventous cis-Platin (100 mg/m{sup 2}) on day 1 and oral Etoposide (50 mg/m{sup 2}/day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred in 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/13) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative

  14. Fiscal 1994 report on technological results. Development of fuel cell technology such as urban energy center (Survey for practical development of optical system of decentralized power source for residential use); 1994 nendo toshi energy center nado nenryo denchi gijutsu kaihatsu seika hokokusho. Minseiyo bunsangata dengen saiteki system jitsuyoka kaihatsu chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    Feasibility study was conducted on the technology for practical application of a several kW class fuel cell for the people's livelihood, particularly, for residential use. The study was made in six areas consisting of study on the present state of technology, conceptual design of a small fuel cell, survey on a promising market, basic concept of cell for residential use, feasibility study on application and on introduction. There is no record of development of the several kW class; while the fuel cell excels in the efficiency of energy utilization and the environmental conservation, its performance greatly deteriorates by start and stop under the present technology. Accordingly, it is a prerequisite that the equipment is for an electric heat combined type and for system interconnection. Also, while it is proper that the cell is phosphate type and that the fuel is natural gas, an innovation is necessary in the technology for reforming the cell and the fuel. The conceptual design revealed the possibility of a power generation system having a generating efficiency of 32%, exhaust heat recovery rate of 30%, and dimension of 75x65x150 cm. On the basis of a feasibility study on the application to the combination of a house and a beauty parlor, an advantage was recognized in the fuel unit cost of 5 yen/meal and the equipment cost of 200-250 thousand yen/kW, with demand estimated for 2.5 million installations nationwide including 950 thousand in natural gas supply districts. (NEDO)

  15. Residential electricity demand in Singapore

    International Nuclear Information System (INIS)

    Ang, B.W.; Goh, T.N.; Liu, X.Q.

    1992-01-01

    Residential electricity consumption in Singapore increased at a rate of 8.8% per year between 1972 and 1990. Estimates of the long-run income and price elasticities are 1.0 and -0.35, respectively. The energy-conservation campaigns that have been launched are found to have marginal effects on consumption. A statistical analysis shows that the consumption is sensitive to small changes in climatic variables, particularly the temperature, which is closely linked to the growing diffusion of electric appliances for environmental controls. There has been a temporal increase in the ownership levels of appliances associated with increasing household incomes. However, other factors were involved since the ownership levels would also increase over time after the elimination of the income effect. A large part of the future growth in electricity demand will arise from the growing need for air-conditioning, which will lead to increasingly large seasonal variations in electricity use. (author)

  16. Residential radon survey in Finland

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Castren, O.

    1993-02-01

    The study measured the indoor radon concentration in the dwellings of 3074 persons, selected randomly from the central population register of Finland. Alpha track detectors and two consecutive half year measuring periods were used. The national mean of indoor radon concentration for persons living in low-rise residential buildings as well as blocks of flats was 145 and 82 Bq/m 3 , respectively. The mean for the total population was 123 Bq/m 3 . Based on the decision of the Ministry of Social Affairs and Health in 1992, the indoor radon concentration should not exceed 400 Bq/m 3 in already existing houses, the target for new construction being less than 200 Bq/m 3 . According to the study, the percentage of the Finnish population living in houses with an indoor radon concentration exceeding 200, 400 and 800 Bq/m 3 was 12.3 %, 3.6 % and 1.0 %

  17. Two-Dimensional Simulation of Mass Transfer in Unitized Regenerative Fuel Cells under Operation Mode Switching

    Directory of Open Access Journals (Sweden)

    Lulu Wang

    2016-01-01

    Full Text Available A two-dimensional, single-phase, isothermal, multicomponent, transient model is built to investigate the transport phenomena in unitized regenerative fuel cells (URFCs under the condition of switching from the fuel cell (FC mode to the water electrolysis (WE mode. The model is coupled with an electrochemical reaction. The proton exchange membrane (PEM is selected as the solid electrolyte of the URFC. The work is motivated by the need to elucidate the complex mass transfer and electrochemical process under operation mode switching in order to improve the performance of PEM URFC. A set of governing equations, including conservation of mass, momentum, species, and charge, are considered. These equations are solved by the finite element method. The simulation results indicate the distributions of hydrogen, oxygen, water mass fraction, and electrolyte potential response to the transient phenomena via saltation under operation mode switching. The hydrogen mass fraction gradients are smaller than the oxygen mass fraction gradients. The average mass fractions of the reactants (oxygen and hydrogen and product (water exhibit evident differences between each layer in the steady state of the FC mode. By contrast, the average mass fractions of the reactant (water and products (oxygen and hydrogen exhibit only slight differences between each layer in the steady state of the WE mode. Under either the FC mode or the WE mode, the duration of the transient state is only approximately 0.2 s.

  18. Durability of Low Platinum Fuel Cells Operating at High Power Density

    Energy Technology Data Exchange (ETDEWEB)

    Polevaya, Olga [Nuvera Fuel Cells Inc.; Blanchet, Scott [Nuvera Fuel Cells Inc.; Ahluwalia, Rajesh [Argonne National Lab; Borup, Rod [Los-Alamos National Lab; Mukundan, Rangachary [Los-Alamos National Lab

    2014-03-19

    Understanding and improving the durability of cost-competitive fuel cell stacks is imperative to successful deployment of the technology. Stacks will need to operate well beyond today’s state-of-the-art rated power density with very low platinum loading in order to achieve the cost targets set forth by DOE ($15/kW) and ultimately be competitive with incumbent technologies. An accelerated cost-reduction path presented by Nuvera focused on substantially increasing power density to address non-PGM material costs as well as platinum. The study developed a practical understanding of the degradation mechanisms impacting durability of fuel cells with low platinum loading (≤0.2mg/cm2) operating at high power density (≥1.0W/cm2) and worked out approaches for improving the durability of low-loaded, high-power stack designs. Of specific interest is the impact of combining low platinum loading with high power density operation, as this offers the best chance of achieving long-term cost targets. A design-of-experiments approach was utilized to reveal and quantify the sensitivity of durability-critical material properties to high current density at two levels of platinum loading (the more conventional 0.45 mgPt.cm–1 and the much lower 0.2 mgPt.cm–2) across several cell architectures. We studied the relevance of selected component accelerated stress tests (AST) to fuel cell operation in power producing mode. New stress tests (NST) were designed to investigate the sensitivity to the addition of electrical current on the ASTs, along with combined humidity and load cycles and, eventually, relate to the combined city/highway drive cycle. Changes in the cathode electrochemical surface area (ECSA) and average oxygen partial pressure on the catalyst layer with aging under AST and NST protocols were compared based on the number of completed cycles. Studies showed elevated sensitivity of Pt growth to the potential limits and the initial particle size distribution. The ECSA loss

  19. Multi-objective design and operation of Solid Oxide Fuel Cell (SOFC) Triple Combined-cycle Power Generation systems: Integrating energy efficiency and operational safety

    International Nuclear Information System (INIS)

    Sharifzadeh, Mahdi; Meghdari, Mojtaba; Rashtchian, Davood

    2017-01-01

    Highlights: • Integrating Solid Oxide Fuel Cells with thermal power plants enhance overall energy efficiency. • However, the high degree of process integration in hybrid power plants limits the operating window. • Multi-objective optimization was applied for integrated design and operation. • The Pareto optimal solutions demonstrated strong trade-off between energy efficiency and operational safety. - Abstract: Energy efficiency is one of the main pathways for energy security and environmental protection. In fact, the International Energy Agency asserts that without energy efficiency, 70% of targeted emission reductions are not achievable. Despite this clarity, enhancing the energy efficiency introduce significant challenge toward process operation. The reason is that the methods applied for energy-saving pose the process operation at the intersection of safety constraints. The present research aims at uncovering the trade-off between safe operation and energy efficiency; an optimization framework is developed that ensures process safety and simultaneously optimizes energy-efficiency, quantified in economic terms. The developed optimization framework is demonstrated for a solid oxide fuel cell (SOFC) power generation system. The significance of this industrial application is that SOFC power plants apply a highly degree of process integration resulting in very narrow operating windows. However, they are subject to significant uncertainties in power demand. The results demonstrate a strong trade-off between the competing objectives. It was observed that highly energy-efficient designs feature a very narrow operating window and limited flexibility. For instance, expanding the safe operating window by 100% will incur almost 47% more annualized costs. Establishing such a trade-off is essential for realizing energy-saving.

  20. Comparative evaluation of alternative technical equipment of residential buildings and analysis of its influence on building and operating costs. Vergleichende Betrachtung alternativer technischer Wohngebaeudeausstattungen und Analyse ihres Einflusses auf Gebaeude- und Betriebskosten

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    In this study energy conservation measures and operating experience in the housing sector are discussed. Five areas are investigated: 1. Water (water-saving fittings and flushings, cold water meters, rain water systems), 2. sewage (grey water plants, compost toilets, plant sewage treatment works), 3. electric power (block heat and power plants, photovoltaic stations, wind turbines, battery storage, energy-saving lamps), 4. heating/hot water (heat pumps, solar collectors, thermal insulation, condensing boilers, stoves, heating systems), 5. ventilation (ventilation control, dust extraction systems). (HW).

  1. ATP-gamma-S shifts the operating point of outer hair cell transduction towards scala tympani.

    Science.gov (United States)

    Bobbin, Richard P; Salt, Alec N

    2005-07-01

    ATP receptor agonists and antagonists alter cochlear mechanics as measured by changes in distortion product otoacoustic emissions (DPOAE). Some of the effects on DPOAEs are consistent with the hypothesis that ATP affects mechano-electrical transduction and the operating point of the outer hair cells (OHCs). This hypothesis was tested by monitoring the effect of ATP-gamma-S on the operating point of the OHCs. Guinea pigs anesthetized with urethane and with sectioned middle ear muscles were used. The cochlear microphonic (CM) was recorded differentially (scala vestibuli referenced to scala tympani) across the basal turn before and after perfusion (20 min) of the perilymph compartment with artificial perilymph (AP) and ATP-gamma-S dissolved in AP. The operating point was derived from the cochlear microphonics (CM) recorded in response low frequency (200 Hz) tones at high level (106, 112 and 118 dB SPL). The analysis procedure used a Boltzmann function to simulate the CM waveform and the Boltzmann parameters were adjusted to best-fit the calculated waveform to the CM. Compared to the initial perfusion with AP, ATP-gamma-S (333 microM) enhanced peak clipping of the positive peak of the CM (that occurs during organ of Corti displacements towards scala tympani), which was in keeping with ATP-induced displacement of the transducer towards scala tympani. CM waveform analysis quantified the degree of displacement and showed that the changes were consistent with the stimulus being centered on a different region of the transducer curve. The change of operating point meant that the stimulus was applied to a region of the transducer curve where there was greater saturation of the output on excursions towards scala tympani and less saturation towards scala vestibuli. A significant degree of recovery of the operating point was observed after washing with AP. Dose response curves generated by perfusing ATP-gamma-S (333 microM) in a cumulative manner yielded an EC(50) of 19.8 micro

  2. An innovative educational program for residential energy efficiency. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Laquatra, J.; Chi, P.S.K.

    1996-09-01

    Recognizing the importance of energy conservation, under sponsorship of the US Department of Energy, Cornell University conducted a research and demonstration project entitled An Innovative Educational Program for Residential Energy Efficiency. The research project examined the amount of residential energy that can be saved through changes in behavior and practices of household members. To encourage these changes, a workshop was offered to randomly-selected households in New York State. Two surveys were administered to household participants (Survey 1 and Survey 2, Appendix A) and a control group; and a manual was developed to convey many easy but effective ways to make a house more energy efficient (see Residential Manual, Appendix B). Implementing methods of energy efficiency will help reduce this country`s dependence on foreign energy sources and will also reduce the amount of money that is lost on inefficient energy use. Because Cornell Cooperative Extension operates as a component of the land-grant university system throughout the US, the results of this research project have been used to develop a program that can be implemented by the Cooperative Extension Service nationwide. The specific goals and objectives for this project will be outlined, the population and sample for the research will be described, and the instruments utilized for the survey will be explained. A description of the workshop and manual will also be discussed. This report will end with a summary of the results from this project and any observed changes and/or recommendations for future surveys pertaining to energy efficiency.

  3. Operation Strategies Based on Carbon Corrosion and Lifetime Investigations for High Temperature Polymer Electrolyte Membrane Fuel Cell Stacks

    DEFF Research Database (Denmark)

    Kannan, A.; Kaczerowski, J.; Kabza, A.

    2018-01-01

    This paper is aimed to develop operation strategies or high temperature polymer electrolyte fuel cells (HT-PEMFCs) stacks in order to enhance the endurance by mitigating carbon oxidation reaction. The testing protocols are carefully designed to suit the operating cycle for the realistic application...

  4. Metachronous adrenal metastasis from operated contralateral renal cell carcinoma with adrenalectomy and iatrogenic Addison's disease.

    Science.gov (United States)

    Ozturk, Hakan; Karaaslan, Serap

    2014-09-01

    Metachronous adrenal metastasis from contralateral renal cell carcinoma (RCC) surgery is an extremely rare condition. Iatrogenic Addison's disease occurring after metastasectomy (adrenalectomy) is an even rarer clinical entity. We present a case of a 68-year-old male with hematuria and left flank pain 9 years prior. The patient underwent left transperitoneal radical nephrectomy involving the ipsilateral adrenal glands due to a centrally-located, 75-mm in diameter solid mass lesion in the upper pole of the left kidney. The tumour lesion was confined within the renal capsule, and the histo-pathological examination revealed a Fuhrman nuclear grade II clear cell carcinoma. The patient underwent transperitoneal right adrenalectomy. The histopathological examination revealed metastasis of clear cell carcinoma. The patient was diagnosed with iatrogenic Addison's disease based on the measurement of serum cortisol levels and the adrenocorticotropic hormone (ACTH) stimulation test, after which glucocorticoid and mineralocorticoid replacement was initiated. The patient did not have local recurrence or new metastasis in the first year of the follow-up. The decision to perform ipsilateral adrenalectomy during radical nephrectomy constitutes a challenge, and the operating surgeon must consider all these rare factors.

  5. Operation of molten carbonate fuel cells with different biogas sources: A challenging approach for field trials

    Science.gov (United States)

    Trogisch, S.; Hoffmann, J.; Daza Bertrand, L.

    In the past years research in the molten carbonate fuel cells (MCFC) area has been focusing its efforts on the utilisation of natural gas as fuel (S. Geitmann, Wasserstoff- & Brennstoffzellen-Projekte, 2002, ISBN 3-8311-3280-1). In order to increase the advantages of this technology, an international consortium has worked on the utilisation of biogas as fuel in MCFC. During the 4 years lasting RTD project EFFECTIVE two different gas upgrading systems have been developed and constructed together with two mobile MCFC test beds which were operated at different locations for approximately 2.000-5.000 h in each run with biogas from different origins and quality. The large variety of test locations has enabled to gather a large database for assessing the effect of the different biogas qualities on the complete system consisting of the upgrading and the fuel cell systems. The findings are challenging. This article also aims at giving an overview of the advantages of using biogas as fuel for fuel cells.

  6. Orbiting compressor for residential air-conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Woo Young; Ahn, Jong Min [Department of Mechanical Engineering, University of Incheon, 12-1 Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea)

    2010-01-15

    A new type of compressor, called an orbiting compressor, is introduced in this paper. The orbiting compressor is characterized by an orbiting piston, and the piston or orbiter consists of a circular base plate and a ring type vane protruding vertically from the base plate. The orbiter is made to orbit in an annular space formed between two concentric circular walls via an Oldham-ring mechanism, producing two sealed gas pockets on both sides of the vane wrap with a 180 phase difference. This operating mechanism leads to alternating compression and discharge processes, which results in low torque variation. The orbiting compressor has been designed for an R410A residential air conditioner with a cooling capacity of 10.0 kW. The performance of the orbiting compressor model has been analytically investigated, where the volumetric, adiabatic and mechanical efficiencies were calculated to be 94.8%, 90.4% and 93.4%, respectively for the ARI condition. The EER was estimated to be about 10.86 with a motor efficiency of 89%. (author)

  7. Optimizing Hydronic System Performance in Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L.; Faakye, O.

    2013-10-01

    Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

  8. Optimal load scheduling in commercial and residential microgrids

    Science.gov (United States)

    Ganji Tanha, Mohammad Mahdi

    Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.

  9. Detecting space-time cancer clusters using residential histories

    Science.gov (United States)

    Jacquez, Geoffrey M.; Meliker, Jaymie R.

    2007-04-01

    Methods for analyzing geographic clusters of disease typically ignore the space-time variability inherent in epidemiologic datasets, do not adequately account for known risk factors (e.g., smoking and education) or covariates (e.g., age, gender, and race), and do not permit investigation of the latency window between exposure and disease. Our research group recently developed Q-statistics for evaluating space-time clustering in cancer case-control studies with residential histories. This technique relies on time-dependent nearest neighbor relationships to examine clustering at any moment in the life-course of the residential histories of cases relative to that of controls. In addition, in place of the widely used null hypothesis of spatial randomness, each individual's probability of being a case is instead based on his/her risk factors and covariates. Case-control clusters will be presented using residential histories of 220 bladder cancer cases and 440 controls in Michigan. In preliminary analyses of this dataset, smoking, age, gender, race and education were sufficient to explain the majority of the clustering of residential histories of the cases. Clusters of unexplained risk, however, were identified surrounding the business address histories of 10 industries that emit known or suspected bladder cancer carcinogens. The clustering of 5 of these industries began in the 1970's and persisted through the 1990's. This systematic approach for evaluating space-time clustering has the potential to generate novel hypotheses about environmental risk factors. These methods may be extended to detect differences in space-time patterns of any two groups of people, making them valuable for security intelligence and surveillance operations.

  10. Caspase-dependent inhibition of store-operated Ca2+ entry into apoptosis-committed Jurkat cells

    International Nuclear Information System (INIS)

    Onopiuk, Marta; Wierzbicka, Katarzyna; Brutkowski, Wojciech; Szczepanowska, Joanna; Zablocki, Krzysztof

    2010-01-01

    Activation of T-cells triggers store-operated Ca 2+ entry, which begins a signaling cascade leading to induction of appropriate gene expression and eventually lymphocyte proliferation and differentiation. The simultaneous enhancement of Fas ligand gene expression in activated cells allows the immune response to be limited by committing the activated cells to apoptosis. In apoptotic cells the store-operated calcium entry is significantly inhibited. It has been documented that moderate activation of Fas receptor may cause reversible inhibition of store-operated channels by ceramide released from hydrolyzed sphingomyelin. Here we show that activation of Fas receptor in T-cells results in caspase-dependent decrease of cellular STIM1 and Orai1 protein content. This effect may be responsible for the substantial inhibition of Ca 2+ entry into Jurkat cells undergoing apoptosis. In turn, this inhibition might prevent overloading of cells with calcium and protect them against necrosis. -- Research highlights: → Fas activation reduces STIM1 and Orai1 protein content in caspase dependent manner. → Fas activation partially reduces mitochondrial potential in caspase dependent manner. → Fas stimulation inhibits of store-operated Ca 2+ entry in caspase dependent manner. → Inhibition of Ca 2+ entry in apoptotic cells may protect them from secondary necrosis.

  11. A roll-to-roll process to flexible polymer solar cells: model studies, manufacture and operational stability studies

    DEFF Research Database (Denmark)

    Krebs, Frederik C; Gevorgyan, Suren; Alstrup, Jan

    2009-01-01

    An inverted polymer solar cell geometry comprising a total of five layers was optimized using laboratory scale cells and the operational stability was studied under model atmospheres. The device geometry was substrate-ITO-ZnO-(active layer)-PEDOT:PSS-silver with P3HT-PCBM as the active layer. The...

  12. 12 CFR 541.23 - Residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Residential real estate. 541.23 Section 541.23... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.23 Residential real estate. The terms residential real estate... home used in part for business); (c) Other real estate used for primarily residential purposes other...

  13. 12 CFR 541.16 - Improved residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Improved residential real estate. 541.16... REGULATIONS AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.16 Improved residential real estate. The term improved residential real estate means residential real estate containing offsite or other improvements...

  14. Particulate and gaseous emissions from residential biomass combustion

    International Nuclear Information System (INIS)

    Boman, Christoffer

    2005-04-01

    Biomass is considered to be a sustainable energy source with significant potentials for replacing electricity and fossil fuels, not at least in the residential sector. However, present wood combustion is a major source of ambient concentrations of hydrocarbons (e.g. VOC and PAH) and particulate matter (PM) and exposure to these pollutants have been associated with adverse health effects. Increased focus on combustion related particulate emissions has been seen concerning the formation, characteristics and implications to human health. Upgraded biomass fuels (e.g. pellets) provide possibilities of more controlled and optimized combustion with less emission of products of incomplete combustion (PICs). For air quality and health impact assessments, regulatory standards and evaluations concerning residential biomass combustion, there is still a need for detailed emission characterization and quantification when using different fuels and combustion techniques. This thesis summarizes the results from seven different papers. The overall objective was to carefully and systematically study the emissions from residential biomass combustion with respect to: i) experimental characterization and quantification, ii) influences of fuel, appliance and operational variables and iii) aspects of ash and trace element transformations and aerosol formation. Special concern in the work was on sampling, quantification and characterization of particulate emissions using different appliances, fuels and operating procedures. An initial review of health effects showed epidemiological evidence of potential adverse effect from wood smoke exposure. A robust whole flow dilution sampling set-up for residential biomass appliances was then designed, constructed and evaluated, and subsequently used in the following emission studies. Extensive quantifications and characterizations of particulate and gases emissions were performed for residential wood and pellet appliances. Emission factor ranges for

  15. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  16. Influence of Macroeconomic Factors on Residential Property ...

    African Journals Online (AJOL)

    Sultan

    exerted by macroeconomic factors on residential property returns in Abuja. The backward .... explanatory power and positive influence of employment and ...... Project. Management In Property Development: the Nigeria experience. Ibadan:.

  17. Plasma Processing of Model Residential Solid Waste

    Science.gov (United States)

    Messerle, V. E.; Mossé, A. L.; Nikonchuk, A. N.; Ustimenko, A. B.; Baimuldin, R. V.

    2017-09-01

    The authors have tested the technology of processing of model residential solid waste. They have developed and created a pilot plasma unit based on a plasma chamber incinerator. The waste processing technology has been tested and prepared for commercialization.

  18. Durability and regeneration of activated carbon air-cathodes in long-term operated microbial fuel cells

    Science.gov (United States)

    Zhang, Enren; Wang, Feng; Yu, Qingling; Scott, Keith; Wang, Xu; Diao, Guowang

    2017-08-01

    The performance of activated carbon catalyst in air-cathodes in microbial fuel cells was investigated over one year. A maximum power of 1722 mW m-2 was produced within the initial one-month microbial fuel cell operation. The air-cathodes produced a maximum power >1200 mW m-2 within six months, but gradually became a limiting factor for the power output in prolonged microbial fuel cell operation. The maximum power decreased by 55% when microbial fuel cells were operated over one year due to deterioration in activated carbon air-cathodes. While salt/biofilm removal from cathodes experiencing one-year operation increased a limiting performance enhancement in cathodes, a washing-drying-pressing procedure could restore the cathode performance to its original levels, although the performance restoration was temporary. Durable cathodes could be regenerated by re-pressing activated carbon catalyst, recovered from one year deteriorated air-cathodes, with new gas diffusion layer, resulting in ∼1800 mW m-2 of maximum power production. The present study indicated that activated carbon was an effective catalyst in microbial fuel cell cathodes, and could be recovered for reuse in long-term operated microbial fuel cells by simple methods.

  19. Method to improve reliability of a fuel cell system using low performance cell detection at low power operation

    Science.gov (United States)

    Choi, Tayoung; Ganapathy, Sriram; Jung, Jaehak; Savage, David R.; Lakshmanan, Balasubramanian; Vecasey, Pamela M.

    2013-04-16

    A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.

  20. Optimization of fuel-cell tram operation based on two dimension dynamic programming

    Science.gov (United States)

    Zhang, Wenbin; Lu, Xuecheng; Zhao, Jingsong; Li, Jianqiu

    2018-02-01

    This paper proposes an optimal control strategy based on the two-dimension dynamic programming (2DDP) algorithm targeting at minimizing operation energy consumption for a fuel-cell tram. The energy consumption model with the tram dynamics is firstly deduced. Optimal control problem are analyzed and the 2DDP strategy is applied to solve the problem. The optimal tram speed profiles are obtained for each interstation which consist of three stages: accelerate to the set speed with the maximum traction power, dynamically adjust to maintain a uniform speed and decelerate to zero speed with the maximum braking power at a suitable timing. The optimal control curves of all the interstations are connected with the parking time to form the optimal control method of the whole line. The optimized speed profiles are also simplified for drivers to follow.

  1. Photoinduced Operation by Absorption of the Chalcogenide Nanocrystallite Containing Solar Cells

    Directory of Open Access Journals (Sweden)

    Elnaggar A.M.

    2016-12-01

    Full Text Available It is shown that for the solar cells containing chalcogenide nanocrystallites using external laser light, one can achieve some enhancement of the photovoltaic efficiency. Photoinduced treatment was carried out using two beams of splitted Er: glass laser operating at 1.54 μm. The light of the laser was incident at different angles and the angles between the beams also were varied. Also, the studies of nanocomposite effective structures have shown enhancement of effective nanocrystalline sizes during the laser treatment. Nanocrystallites of CuInS2 and CuZnSnS4 (CZTS were used as chalcogenide materials. The optimization of the laser beam intensities and nanoparticle sizes were explored.

  2. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  3. Catalytic and electrochemical behaviour of solid oxide fuel cell operated with simulated-biogas mixtures

    Science.gov (United States)

    Dang-Long, T.; Quang-Tuyen, T.; Shiratori, Y.

    2016-06-01

    Being produced from organic matters of wastes (bio-wastes) through a fermentation process, biogas mainly composed of CH4 and CO2 and can be considered as a secondary energy carrier derived from solar energy. To generate electricity from biogas through the electrochemical process in fuel cells is a state-of-the-art technology possessing higher energy conversion efficiency without harmful emissions compared to combustion process in heat engines. Getting benefits from high operating temperature such as direct internal reforming ability and activation of electrochemical reactions to increase overall system efficiency, solid oxide fuel cell (SOFC) system operated with biogas becomes a promising candidate for distributed power generator for rural applications leading to reductions of environmental issues caused by greenhouse effects and bio-wastes. CO2 reforming of CH4 and electrochemical oxidation of the produced syngas (H2-CO mixture) are two main reaction processes within porous anode material of SOFC. Here catalytic and electrochemical behavior of Ni-ScSZ (scandia stabilized-zirconia) anode in the feed of CH4-CO2 mixtures as simulated-biogas at 800 °C were evaluated. The results showed that CO2 had strong influences on both reaction processes. The increase in CO2 partial pressure resulted in the decrease in anode overvoltage, although open-circuit voltage was dropped. Besides that, the simulation result based on a power-law model for equimolar CH4-CO2 mixture revealed that coking hazard could be suppressed along the fuel flow channel in both open-circuit and closed-circuit conditions.

  4. Catalytic and electrochemical behaviour of solid oxide fuel cell operated with simulated-biogas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Dang-Long, T., E-mail: 3TE14098G@kyushu-u.ac.jp [Department of Hydrogen Energy Systems, Faculty of Engineering, Kyushu University Motooka 744, Nishiku, Fukuoka, 810-0395 (Japan); Quang-Tuyen, T., E-mail: tran.tuyen.quang.314@m.kyushu-u.ac.jp [International Research Center for Hydrogen Energy, Kyushu University Motooka 744, Nishiku, Fukuoka, 810-0395 (Japan); Shiratori, Y., E-mail: shiratori.yusuke.500@m.kyushu-u.ac.jp [Department of Hydrogen Energy Systems, Faculty of Engineering, Kyushu University Motooka 744, Nishiku, Fukuoka, 810-0395 (Japan); International Research Center for Hydrogen Energy, Kyushu University Motooka 744, Nishiku, Fukuoka, 810-0395 (Japan)

    2016-06-03

    Being produced from organic matters of wastes (bio-wastes) through a fermentation process, biogas mainly composed of CH{sub 4} and CO{sub 2} and can be considered as a secondary energy carrier derived from solar energy. To generate electricity from biogas through the electrochemical process in fuel cells is a state-of-the-art technology possessing higher energy conversion efficiency without harmful emissions compared to combustion process in heat engines. Getting benefits from high operating temperature such as direct internal reforming ability and activation of electrochemical reactions to increase overall system efficiency, solid oxide fuel cell (SOFC) system operated with biogas becomes a promising candidate for distributed power generator for rural applications leading to reductions of environmental issues caused by greenhouse effects and bio-wastes. CO{sub 2} reforming of CH{sub 4} and electrochemical oxidation of the produced syngas (H{sub 2}–CO mixture) are two main reaction processes within porous anode material of SOFC. Here catalytic and electrochemical behavior of Ni-ScSZ (scandia stabilized-zirconia) anode in the feed of CH{sub 4}–CO{sub 2} mixtures as simulated-biogas at 800 °C were evaluated. The results showed that CO{sub 2} had strong influences on both reaction processes. The increase in CO{sub 2} partial pressure resulted in the decrease in anode overvoltage, although open-circuit voltage was dropped. Besides that, the simulation result based on a power-law model for equimolar CH{sub 4}−CO{sub 2} mixture revealed that coking hazard could be suppressed along the fuel flow channel in both open-circuit and closed-circuit conditions.

  5. Integration of Solar Photovoltaics and Electric Vehicles in Residential Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2013-01-01

    In the last few years, there is an increased penetration of solar photovoltaic (SPV) units in low voltage (LV) distribution grids. Also electric vehicles (EVs) are introduced to these LV networks. This has caused the distribution networks to be more active and complex as these local generation...... and load units are characterised by unpredictable and diverse operating characteristics. This paper analyses the combined effect of SPVs and EVs in LV Danish residential grids. The EVs charging needs based on typical driving patterns of passenger cars and SPV power profiles during winter/summer days...

  6. A Decentralized Storage Strategy for Residential Feeders with Photovoltaics

    DEFF Research Database (Denmark)

    Marra, Francesco; Yang, Guangya; Træholt, Chresten

    2014-01-01

    . The power sizing of the ESSs is performed with linear programming (LP) method, based on voltage sensitivity analysis. A Belgian residential LV feeder with private PV systems is used as a case study to demonstrate the effectiveness of the proposed strategy. Quantification of the required energy levels...... domestic energy storage systems (ESS). The traditional way of operating a domestic ESS to increase the local consumption rate does not take into account the need of voltage support in a feeder; the proposed storage concept improves the traditional one, by mitigating voltage rise due to PV in the feeder...

  7. A selective electrocatalyst-based direct methanol fuel cell operated at high concentrations of methanol.

    Science.gov (United States)

    Feng, Yan; Liu, Hui; Yang, Jun

    2017-06-01

    Owing to the serious crossover of methanol from the anode to the cathode through the polymer electrolyte membrane, direct methanol fuel cells (DMFCs) usually use dilute methanol solutions as fuel. However, the use of high-concentration methanol is highly demanded to improve the energy density of a DMFC system. Instead of the conventional strategies (for example, improving the fuel-feed system, membrane development, modification of electrode, and water management), we demonstrate the use of selective electrocatalysts to run a DMFC at high concentrations of methanol. In particular, at an operating temperature of 80°C, the as-fabricated DMFC with core-shell-shell Au@Ag 2 S@Pt nanocomposites at the anode and core-shell Au@Pd nanoparticles at the cathode produces a maximum power density of 89.7 mW cm -2 at a methanol feed concentration of 10 M and maintains good performance at a methanol concentration of up to 15 M. The high selectivity of the electrocatalysts achieved through structural construction accounts for the successful operation of the DMFC at high concentrations of methanol.

  8. A selective electrocatalyst–based direct methanol fuel cell operated at high concentrations of methanol

    Science.gov (United States)

    Feng, Yan; Liu, Hui; Yang, Jun

    2017-01-01

    Owing to the serious crossover of methanol from the anode to the cathode through the polymer electrolyte membrane, direct methanol fuel cells (DMFCs) usually use dilute methanol solutions as fuel. However, the use of high-concentration methanol is highly demanded to improve the energy density of a DMFC system. Instead of the conventional strategies (for example, improving the fuel-feed system, membrane development, modification of electrode, and water management), we demonstrate the use of selective electrocatalysts to run a DMFC at high concentrations of methanol. In particular, at an operating temperature of 80°C, the as-fabricated DMFC with core-shell-shell Au@Ag2S@Pt nanocomposites at the anode and core-shell Au@Pd nanoparticles at the cathode produces a maximum power density of 89.7 mW cm−2 at a methanol feed concentration of 10 M and maintains good performance at a methanol concentration of up to 15 M. The high selectivity of the electrocatalysts achieved through structural construction accounts for the successful operation of the DMFC at high concentrations of methanol. PMID:28695199

  9. Integrated anode structure for passive direct methanol fuel cells with neat methanol operation

    Science.gov (United States)

    Wu, Huijuan; Zhang, Haifeng; Chen, Peng; Guo, Jing; Yuan, Ting; Zheng, Junwei; Yang, Hui

    2014-02-01

    A microporous titanium plate based integrated anode structure (Ti-IAS) suitable for passive direct methanol fuel cells (DMFCs) fueled with neat methanol is reported. This anode structure incorporates a porous titanium plate as a methanol mass transfer barrier and current collector, pervaporation film for passively vaporizing methanol, vaporous methanol cavity for evenly distributing fuel, and channels for carbon dioxide venting. With the effective control of methanol delivery rate, the Ti-IAS based DMFC allows the direct use of neat methanol as the fuel source. In the meantime, the required water for methanol-oxidation reaction at the anode can also be fully recovered from the cathode with the help of the highly hydrophobic microporous layer in the cathode. DMFCs incorporating this new anode structure exhibit a power density as high as 40 mW cm-2 and a high volumetric energy density of 489 Wh L-1 operating with neat methanol and at 25 °C. Importantly, no obvious performance degradation of the passive DMFC system is observed after more than 90 h of continuous operation. The experimental results reveal that the compact DMFC based on the Ti-IAS exhibits a substantial potential as power sources for portable applications.

  10. The 1986 residential occupant survey

    Energy Technology Data Exchange (ETDEWEB)

    Ivey, D.L.; Alley, P.K.

    1987-04-01

    In 1986, Pacific Northwest Laboratory developed the Residential Occupant Survey-Spring '86, which was implemented. The overall purpose of the study was to collect demographic, attitudinal, and behavioral data related to the use and conservation of electricity in dwellings participating in the Bonneville Power Administration's End-Use Load and Conservation Assessment Program (ELCAP). Information was collected on the respondents' perceptions of the energy efficiency of their dwelling, temperature the dwelling was kept when people were at home and awake during the last heating season, which rooms, if any, were not heated during the last heating season, number of times the dwelling was unoccupied for at least one week, number of times pets were let out of the dwelling per day, attitudes toward energy use and conservation and several socio-demographic variables such as age, sex, and total household income. The results of the data analyses showed age to be an important factor for reported indoor temperature and perceived energy efficiency of the dwelling. The results also showed that almost 60% of the ELCAP occupants do not heat one or more rooms during the heating season, and almost 45% of the ELCAP dwellings were unoccupied for at least one week during the reporting period. In terms of the reported allocation of household income for household energy expenses, the results showed that the reported dollar amount spent for the expenses remained relatively constant over income levels.

  11. Design of an overhead crane for the ITER NB cell remote handling maintenance operations

    Energy Technology Data Exchange (ETDEWEB)

    Taubmann, Gonzalo; Brochet, Laurent [IBERTEF A.I.E., Iberica de Tecnologia de Fusion, C/Magallanes 3, 28015 Madrid (Spain); Liniers, Macarena [Asociacion EURATOM-CIEMAT para la Fusion, Av. Complutense 22, 28040 Madrid (Spain)], E-mail: macarena.liniers@ciemat.es; Medrano, Mercedes; Sarasola, Xabier; Botija, Jose; Alonso, Javier [Asociacion EURATOM-CIEMAT para la Fusion, Av. Complutense 22, 28040 Madrid (Spain); Damiani, Carlo [FUSION FOR ENERGY, Josep Pla 2, Torres Diagonal Litoral Ed B3, 08019 Barcelona (Spain)

    2009-06-15

    In the neutral beam cell of ITER all the maintenance operations on the neutral beam components (BLC's) must be performed by an overhead crane of large payload capability (30-50 tonnes). A crane system is presented consisting of a monorail, a carriage, and a lifting mechanism. The monorail must give access to the BLC's in the beam line vessel, the front components connecting the NB vessel with the Tokamak, and a storage area at the north end of the NB cell. Rail switching points are required at the intersections between radial and toroidal branches. A translational switching mechanism is proposed. The crane carriage consists of two independent sub-carriages, each composed of four wheels. A set of four secondary wheels attached to the main carriage prevents the crane tilting due to the CoG misalignment of some loads. The elevation system proposed consists of an electromechanical crane of four independent drums and 50 tonnes payload. In parallel with the crane design, a logistics and space availability study has been carried out, leading to the detection of clearance or transport problems that could be taken into account in the final crane design.

  12. Design of an overhead crane for the ITER NB cell remote handling maintenance operations

    International Nuclear Information System (INIS)

    Taubmann, Gonzalo; Brochet, Laurent; Liniers, Macarena; Medrano, Mercedes; Sarasola, Xabier; Botija, Jose; Alonso, Javier; Damiani, Carlo

    2009-01-01

    In the neutral beam cell of ITER all the maintenance operations on the neutral beam components (BLC's) must be performed by an overhead crane of large payload capability (30-50 tonnes). A crane system is presented consisting of a monorail, a carriage, and a lifting mechanism. The monorail must give access to the BLC's in the beam line vessel, the front components connecting the NB vessel with the Tokamak, and a storage area at the north end of the NB cell. Rail switching points are required at the intersections between radial and toroidal branches. A translational switching mechanism is proposed. The crane carriage consists of two independent sub-carriages, each composed of four wheels. A set of four secondary wheels attached to the main carriage prevents the crane tilting due to the CoG misalignment of some loads. The elevation system proposed consists of an electromechanical crane of four independent drums and 50 tonnes payload. In parallel with the crane design, a logistics and space availability study has been carried out, leading to the detection of clearance or transport problems that could be taken into account in the final crane design.

  13. Effect of operating conditions on energy efficiency for a small passive direct methanol fuel cell

    International Nuclear Information System (INIS)

    Chu Deryn; Jiang Rongzhong

    2006-01-01

    Energy conversion efficiency was studied in a direct methanol fuel cell (DMFC) with an air-breathing cathode using Nafion 117 as electrolyte membrane. The effect of operating conditions, such as methanol concentration, discharge voltage and temperature, on Faradic and energy conversion efficiencies was analyzed under constant voltage discharge with quantitative amount of fuel. Both of Faradic and energy conversion efficiencies decrease significantly with increasing methanol concentration and environmental temperature. The Faradic conversion efficiency can be as high as 94.8%, and the energy conversion efficiency can be as high as 23.9% if the environmental temperature is low enough (10 deg. C) under constant voltage discharge at 0.6 V with 3 M methanol for a DMFC bi-cell. Although higher temperature and higher methanol concentration can achieve higher discharge power, it will result in considerable losses of Faradic and energy conversion efficiencies for using Nafion electrolyte membrane. Development of alternative highly conductive membranes with significantly lower methanol crossover is necessary to avoid loss of Faradic conversion efficiency with temperature and with fuel concentration

  14. In-home performance of residential cordwood stoves

    International Nuclear Information System (INIS)

    Houck, J.E.; Barnett, S.G.; Roholt, R.B.

    1991-01-01

    The air quality impacts of residential cordwood stoves have been of concern to regulators, energy planners, and members of the woodstove industry. In addition, the reliability of laboratory certification emission values in predicting 'real world' emissions has been questioned. In response to these concerns, particulate emissions from residential cordwood stoves under actual in-home use have been measured for 5 heating seasons as part of 12 separate studies in Oregon, New York, Vermont, and the Yukon Territory. Monitoring was conducted using an automated emission sampler (AES) system. The system has been deployed in nearly 100 individual homes. Typically, emissions from several 1-week-long integrated sampling periods over the course of the heating season were measured with the AES system at each home. Particulate emission rates in grams of particles per hour of stove operation, grams of particles per kilogram of dry wood burned, and grams of particles per million Joules were calculated. Ancillary data provided by the studies included wood burn rates, homeowner wood loading patterns, wood moisture content and species, hours of operation of auxiliary heating appliances in the study homes, room ambient, flue gas, catalyst, and pre-catalyst temperatures, and hours of catalyst operation. Conventional stoves, high-technology non-catalytic stoves, catalytic stoves, and stoves equipped with retrofit catalytic devices have been studied. In addition to the 12 cordwood stove studies, the AES system has been used in 2 pellet stove studies and 1 fireplace study

  15. Analysis, operation and maintenance of a fuel cell/battery series-hybrid bus for urban transit applications

    Energy Technology Data Exchange (ETDEWEB)

    Bubna, Piyush; Brunner, Doug; Gangloff, John J. Jr.; Advani, Suresh G.; Prasad, Ajay K. (Center for Fuel Cell Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716 United States)

    2010-06-15

    The fuel cell hybrid bus (FCHB) program was initiated at the University of Delaware in 2005 to demonstrate the viability of fuel cell vehicles for transit applications and to conduct research and development to facilitate the path towards their eventual commercialization. Unlike other fuel cell bus programs, the University of Delaware's FCHB design features a battery-heavy hybrid which offers multiple advantages in terms of cost, performance and durability. The current fuel cell hybrid bus is driven on a regular transit route at the University of Delaware. The paper describes the baseline specifications of the bus with a focus on the fuel cell and the balance of plant. The fuel cell/battery series-hybrid design is well suited for urban transit routes and provides key operational advantages such as hydrogen fuel economy, efficient use of the fuel cell for battery recharging, and regenerative braking. The bus is equipped with a variety of sensors including a custom-designed cell voltage monitoring system which provide a good understanding of bus performance under normal operation. Real-time data collection and analysis have yielded key insights for fuel cell bus design optimization. Results presented here illustrate the complex flow of energy within the various subsystems of the fuel cell hybrid bus. A description of maintenance events has been included to highlight the issues that arise during general operation. The paper also describes several modifications that will facilitate design improvements in future versions of the bus. Overall, the fuel cell hybrid bus demonstrates the viability of fuel cells for urban transit applications in real world conditions. (author)

  16. Analysis, operation and maintenance of a fuel cell/battery series-hybrid bus for urban transit applications

    Science.gov (United States)

    Bubna, Piyush; Brunner, Doug; Gangloff, John J.; Advani, Suresh G.; Prasad, Ajay K.

    The fuel cell hybrid bus (FCHB) program was initiated at the University of Delaware in 2005 to demonstrate the viability of fuel cell vehicles for transit applications and to conduct research and development to facilitate the path towards their eventual commercialization. Unlike other fuel cell bus programs, the University of Delaware's FCHB design features a battery-heavy hybrid which offers multiple advantages in terms of cost, performance and durability. The current fuel cell hybrid bus is driven on a regular transit route at the University of Delaware. The paper describes the baseline specifications of the bus with a focus on the fuel cell and the balance of plant. The fuel cell/battery series-hybrid design is well suited for urban transit routes and provides key operational advantages such as hydrogen fuel economy, efficient use of the fuel cell for battery recharging, and regenerative braking. The bus is equipped with a variety of sensors including a custom-designed cell voltage monitoring system which provide a good understanding of bus performance under normal operation. Real-time data collection and analysis have yielded key insights for fuel cell bus design optimization. Results presented here illustrate the complex flow of energy within the various subsystems of the fuel cell hybrid bus. A description of maintenance events has been included to highlight the issues that arise during general operation. The paper also describes several modifications that will facilitate design improvements in future versions of the bus. Overall, the fuel cell hybrid bus demonstrates the viability of fuel cells for urban transit applications in real world conditions.

  17. Migration of gases around a cell containing high-activity vitrified wastes during the operational phase

    International Nuclear Information System (INIS)

    Hoch, A.; Wendling, J.

    2010-01-01

    Document available in extended abstract form only. Andra is studying the Callovo-Oxfordian mud-stones, located at a depth of approximately 500 m beneath the borders of the Meuse and the Haute-Marne Departements, in order to assess the feasibility of constructing a repository for radioactive waste in this low-permeability geological formation. Several categories of waste are being considered for disposal in the geological repository. Of these, the high-activity, long-lived vitrified wastes (known as 'Waste C') are strongly exothermic and will be stored in cells that are about 40 m long, with a single access aperture from an access gallery. The cell wall will be supported by a steel lining. During the reversible operational phase (lasting at least 100 years), and as long as the access galleries are ventilated, the corrosion of the steel lining by oxygen in air will be important. It is necessary to determine the thickness of the lining corroded during this phase in order to be able to design the lining with an appropriate initial thickness to maintain integrity. In addition, at the end of the cell farthest from the ventilated access gallery, it is possible that the oxygen concentration will be so low that corrosion occurs under reducing (anaerobic) conditions. This chemical reaction produces hydrogen gas, which will migrate towards the access gallery. To maintain operational safety, it is necessary to define the hydrogen concentration within the cell and within the access gallery in order to evaluate the fire and/or explosion hazards (the hydrogen-oxygen mixture is highly flammable and/or explosive at certain concentrations). The objectives of this study were to estimate for the reversible operational phase (i.e. for 100 years): - The thickness of the steel lining required to ensure mechanical integrity. - Transfer rates (advection and / or diffusion) and gas concentrations (oxygen, hydrogen and water vapour) at all points in the annular void between the

  18. Fraudsters operate and officialdom turns a blind eye: a proposal for controlling stem cell therapy in China.

    Science.gov (United States)

    Jiang, Li; Dong, Bing He

    2016-09-01

    Stem cell tourism-the flow of patients from home countries to destination countries to obtain stem cell treatment-is a growing business in China. Many concerns have been raised regarding fraudsters that operate unsafe stem cell therapies and an officialdom that turns a blind eye to the questionable technology. The Chinese regulatory approach to stem cell research is based on Guidelines and Administrative Measures, rather than legislation, and may have no binding force on certain institutions, such as military hospitals. There is no liability and traceability system and no visible set of penalties for non-compliance in the stem cell legal framework. In addition to the lack of safety and efficacy systems in the regulations, no specific expert authority has been established to monitor stem cell therapy to date. Recognizing the global nature of stem cell tourism, this article argues that resolving stem cell tourism issues may require not only the Chinese government but also an international mechanism for transparency and ethical oversight. A stringent set of international regulations that govern stem cell therapies can encourage China to improve stem cell regulation and enforcement to fulfill its obligations. Through an international consensus, a minimum standard for clinical stem cell research and a central enforcement system will be provided. As a result, rogue clinics that conduct unauthorized stem cell therapies can be penalized, and countries that are reluctant to implement the reconciled regulations should be sanctioned.

  19. Differences between Residential and Non-Residential Fathers on Sexual Socialisation of African American Youth

    Science.gov (United States)

    Sneed, Carl D.; Willis, Leigh A.

    2016-01-01

    This study investigated differences between residential and non-residential fathers on topics discussed during father-child sex communication and factors associated with child sexual socialisation. Young people (N = 159, 53% female) provided self-reports using computer surveys on the role of their fathers on father-child sex communication, general…

  20. Review of Residential Comfort Control Products and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, Cheryn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Goyal, Siddharth [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Baechler, Michael C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-12-15

    This paper begins by discussing the interaction of each major component in advanced sensor and control applications related to HVAC equipment. The paper also looks at the applications of these components to commissioning, maintenance and operations of the HVAC equipment in residential buildings. A summary of state-of-the-art product features is also provided. These products are categorized through their primary application type (commissioning/maintenance or operation) and the features are categorized by component type (sensors, data storage, human-in-the-loop, communication, and controls). A common theme that emerges from this study is the importance of the ability for various product categories to be connected to each other. There are many manufacturers of sensors and many manufacturers of controls, but the power to automate any commissioning, maintenance or operation application, requires connectivity.

  1. LONG-TERM PERFORMANCE OF SOLID OXIDE STACKS WITH ELECTRODE-SUPPORTED CELLS OPERATING IN THE STEAM ELECTROLYSIS MODE

    Energy Technology Data Exchange (ETDEWEB)

    J. E. O' Brien; R. C. O' Brien; X. Zhang; G. Tao; B. J. Butler

    2011-11-01

    Performance characterization and durability testing have been completed on two five-cell high-temperature electrolysis stacks constructed with advanced cell and stack technologies. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. The per-cell active area is 100 cm2. The stack is internally manifolded with compliant mica-glass seals. Treated metallic interconnects with integral flow channels separate the cells. Stack compression is accomplished by means of a custom spring-loaded test fixture. Initial stack performance characterization was determined through a series of DC potential sweeps in both fuel cell and electrolysis modes of operation. Results of these sweeps indicated very good initial performance, with area-specific resistance values less than 0.5 ?.cm2. Long-term durability testing was performed with A test duration of 1000 hours. Overall performance degradation was less than 10% over the 1000-hour period. Final stack performance characterization was again determined by a series of DC potential sweeps at the same flow conditions as the initial sweeps in both electrolysis and fuel cell modes of operation. A final sweep in the fuel cell mode indicated a power density of 0.356 W/cm2, with average per-cell voltage of 0.71 V at a current of 50 A.

  2. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  3. The push factors of intra-urban residential mobility in Calabar, Nigeria

    African Journals Online (AJOL)

    The paper takes a critical look at the push factors of intra-urban residential mobility in Calabar. Push factors are defined as those which operate to induce or encourage households to change their residence in the city. The paper notes that changing of residence by urban households in Western cities is a common ...

  4. TRANSIENT AND STEADY STATE STUDY OF PURE AND MIXED REFRIGERANTS IN A RESIDENTIAL HEAT PUMP

    Science.gov (United States)

    The report gives results of an experimental and theoretical investigation of the transient and steady state performance of a residential air-conditioning/heat pump (AC/HP) operating with different refrigerants. (NOTE: The project was motivated by environmental concerns related to...

  5. Distributed generation in the Dutch LV network - self-supporting residential area

    NARCIS (Netherlands)

    Mes, M.; Vanalme, G.M.A.; Myrzik, J.M.A.; Bongaerts, M.; Verbong, G.P.J.; Kling, W.L.

    2008-01-01

    A self-supporting residential area is seen as an alternative operational approach of power supply in low voltage (LV) networks. The intention of the new approach is to exploit the advantages of distributed generation (DG) and avoid the difficulties, that come with DG when implemented in the

  6. Multi-Level Energy Management and Optimal Control of a Residential DC Microgrid

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Anvari-Moghaddam, Amjad; Quintero, Juan Carlos Vasquez

    2017-01-01

    of a residential DC microgrid (R-DCMG) with different distributed generations (DGs) and loads is proposed and implemented as an optimal hierarchical control strategy. A system-level optimizer is designed to calculate the optimal operating points of the controllable energy sources (CESs) when needed, while lower......-level controllers are utilized to enforce the CESs to follow optimal set-points....

  7. Comparison of microbial electrolysis cells operated with added voltage or by setting the anode potential

    KAUST Repository

    Nam, Joo-Youn

    2011-08-01

    Hydrogen production in a microbial electrolysis cell (MEC) can be achieved by either setting the anode potential with a potentiostat, or by adding voltage to the circuit with a power source. In batch tests the largest total gas production (46 ± 3 mL), lowest energy input (2.3 ± 0.3 kWh/m 3 of H2 generated), and best overall energy recovery (E+S = 58 ± 6%) was achieved at a set anode potential of EAn = -0.2 V (vs Ag/AgCl), compared to set potentials of -0.4 V, 0 V and 0.2 V, or an added voltage of Eap = 0.6 V. Gas production was 1.4 times higher with EAn = -0.2 V than with Eap = 0.6 V. Methane production was also reduced at set anode potentials of -0.2 V and higher than the other operating conditions. Continuous flow operation of the MECs at the optimum condition of EAn = -0.2 V initially maintained stable hydrogen gas production, with 68% H2 and 21% CH4, but after 39 days the gas composition shifted to 55% H2 and 34% CH 4. Methane production was not primarily anode-associated, as methane was reduced to low levels by placing the anode into a new MEC housing. These results suggest that MEC performance can be optimized in terms of hydrogen production rates and gas composition by setting an anode potential of -0.2 V, but that methanogen proliferation must be better controlled on non-anodic surfaces. © 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

  8. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  9. Reversible Operation of Solid Oxide Cells for Sustainable Fuel Production and Solar/Wind Load-Balancing

    DEFF Research Database (Denmark)

    Graves, Christopher R.; Villarreal, D.; Mýrdal, Jón Steinar Garðarsson

    2016-01-01

    with focus onfundamentals or applications of bi-directional operation. This presentation will highlight ourrecent developments in applying reversible SOCs (RSOCs) for renewable energy storagewith respect to cell and stack testing, cell and system design, and techno-economicanalysis.At the cell level, long...... exceeds the wind power supply.At the system level, techno-economic analyses and system designs for different scalesand applications have been realized. A simulation of an RSOC system that uses real-worldtime-series market prices for electricity and natural gas in Denmark to decide when tooperate...... in electrolysis mode (buying electricity and selling methane) or fuel-cell mode(buying gas and selling electricity) shows the advantage of a reversible system and thechanging operating profile as the fraction of wind power supply grows. Finally, we discussthe potential for systems with novel chemistries...

  10. New Polymer Electrolyte Membranes Based on Acid Doped PBI For Fuel Cells Operating above 100°C

    DEFF Research Database (Denmark)

    Li, Qingfeng

    2003-01-01

    The technical achievement and challenges for the PEMFC technology based on perfluorosulfonic acid (PFSA) polymer membranes (e.g. Nafion®) are briefly discussed. The newest development for alternative polymer electrolytes for operation above 100°C. As one of the successful approaches to high...... operational temperatures, the development and evaluation of acid doped PBI membranes are reviewed, covering polymer synthesis, membrane casting, acid doping, physiochemical characterization and fuel cell tests....

  11. An XAS experimental approach to study low Pt content electrocatalysts operating in PEM fuel cells.

    Science.gov (United States)

    Principi, Emiliano; Witkowska, Agnieszka; Dsoke, Sonia; Marassi, Roberto; Di Cicco, Andrea

    2009-11-21

    We present an X-ray absorption spectroscopy (XAS) study of a low Pt content catalyst layer (Pt loading 0.1 mg cm(-2)) operating at the cathode of a proton exchange membrane fuel cell (PEMFC). This catalyst is based on the use of a mesoporous inorganic matrix as a support for the catalyst Pt nanoparticles. Due to the high Pt dilution, in situ measurements of its structural properties by XAS are challenging and suitable experimental strategies must be devised for this purpose. In particular, we show that accurate XAS in situ fluorescence measurements can be obtained using an optimized fuel cell, suitable protocols for alignment of a focused X-ray beam and an appropriate filter for the background signal of the other atomic species contained in the electrodes. Details, advantages and limitations of the XAS technique for in situ measurements are discussed. Analysis of the near-edge XAS and EXAFS (extended X-ray absorption fine structure) data, corroborated by a HRTEM (high-resolution transmission electron microscopy) study, shows that the Pt particles have a local structure compatible with that of bulk Pt (fcc) and coordination numbers match those expected for particles with typical sizes in the 1.5-2.0 nm range. Substantial changes in the oxidation state and in local atomic arrangement of the Pt particles are found for different applied potentials. The catalyst support, containing W atoms, exhibits a partial reduction upon PEMFC activation, thus mimicking the catalyst behavior. This indicates a possible role of the mesoporous matrix in favouring the oxygen reduction reaction (ORR) and stimulates further research on active catalyst supports.

  12. Use of wastewater treatment plant biogas for the operation of Solid Oxide Fuel Cells (SOFCs).

    Science.gov (United States)

    Lackey, Jillian; Champagne, Pascale; Peppley, Brant

    2017-12-01

    Solid Oxide Fuel Cells (SOFCs) perform well on light hydrocarbon fuels, and the use of biogas derived from the anaerobic digestion (AD) of municipal wastewater sludges could provide an opportunity for the CH 4 produced to be used as a renewable fuel. Greenhouse gas (GHG), NO x , SO x , and hydrocarbon pollutant emissions would also be reduced. In this study, SOFCs were operated on AD derived biogas. Initially, different H 2 dilutions were tested (N 2 , Ar, CO 2 ) to examine the performance of tubular SOFCs. With inert gases as diluents, a decrease in cell performance was observed, however, the use of CO 2 led to a higher decrease in performance as it promoted the reverse water-gas shift (WGS) reaction, reducing the H 2 partial pressure in the gas mixture. A model was developed to predict system efficiency and GHG emissions. A higher electrical system efficiency was noted for a steam:carbon ratio of 2 compared to 1 due to the increased H 2 partial pressure in the reformate resulting from higher H 2 O concentration. Reductions in GHG emissions were estimated at 2400 tonnes CO 2 , 60 kg CH 4 and 18 kg N 2 O. SOFCs were also tested using a simulated biogas reformate mixture (66.7% H 2 , 16.1% CO, 16.5% CO 2 , 0.7% N 2 , humidified to 2.3 or 20 mol% H 2 O). Higher humidification yielded better performance as the WGS reaction produced more H 2 with additional H 2 O. It was concluded that AD-derived biogas, when cleaned to remove H 2 S, Si compounds, halides and other contaminants, could be reformed to provide a clean, renewable fuel for SOFCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Design, Construction and Operation of a Molten Carbonate Fuel Cell (MCFC) in the 100-kW-Class

    International Nuclear Information System (INIS)

    Heiming, Andreas; Huppmann, Gerhard; Aasberg-Petersen, Kim

    1999-01-01

    In fuel cells, the electrochemical energy of the fuel is converted directly into electricity and heat. The electrochemical conversion is inherently related to high electrical efficiencies and very low pollutant emissions. Fuel cells with sufficiently high operating temperatures such as (1) the phosphoric acid fuel cell (PAFC), operating temperature: 200 o C, (2) the molten carbonate fuel cell (MCFC), operating temperature: 650 o C and (3) the solid oxide fuel cell (SOFC), operating temperature: around 900 o C are best suited for decentralised combined heat and power (CHP) applications. This is due to the fact, that the heat of the exothermic reaction taking place in the fuel cell can be used in the domestic, commercial and industrial sector for heating and hot water or steam production. At the present time, gas-engines or gas-turbines are the preferred CHP-technologies for these applications. Nowadays, the PAFC is commercially available. More than 160 plants, each with a power of 200 kW, have been installed world-wide. Ruhrgas has investigated the behaviour of a 200 kW PAFC at its research centre in Dorsten, Germany, and at the site of a local utility. High temperature fuel cells such as MCFC or SOFC promise electrical efficiencies above 50 % in simple cycle mode. Up to now, MCFC-test plants have been built and operated in the 100 kW to 1 MW power range. The largest MCFC ever operated consisted of 16 identical stacks of 125 kW each, resulting in a plant power of 2 MW. The initial experience with SOFC in this power-range is currently gained from the operation of a 100 kW plant. In this paper, the result of the construction and operation of a highly innovatively designed 280 kW MCFC will be presented. This plant has been designed, built and operated by a European consortium for the development and market introduction of the MCFC. Members of the consortium are MTU-Friedrichshafen GmbH, Haldor Topsoee NS, Elkraft A.m.b.H., RWE Energie AG and Ruhrgas AG. (author)

  14. Residential Pre-Cooling: Mechanical Cooling and Air-Side Economizers:

    OpenAIRE

    Turner, William J.N; Walker, Iain S.; Roux, Jordan

    2012-01-01

    This study used an advanced airflow, energy and humidity modeling tool to evaluate residential air-side economizers and mechanical pre-cooling strategies using the air conditioner, in all US DOE Climate Zones for a typical new home with ASHRAE Standard 62.2 compliant ventilation. A residential air-side economizer is a large supply fan used for night ventilation. Mechanical pre-cooling used the building air conditioner operating at lower than usual set before the peak demand period. The simula...

  15. The bottom line: an ethnography of for-profit elderly residential care

    OpenAIRE

    Greener, Joe

    2011-01-01

    In the last 20 years the UK’s elderly residential care system has become progressively more privatised with an increase in the number of for-profit organisations delivering these services. This study is a participant observation of care work in one privatised elderly residential care home (‘Meadowvale’), owned and operated by a large provider of such services (‘Moonlight Care’). It provides a rich ethnographic depiction of life at Meadowvale both from the point of view of the workers and the ...

  16. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  17. Residentialization of Public Spaces: Bratislava Example

    Science.gov (United States)

    Bacová, Andrea; Puškár, Branislav; Vráblová, Edita

    2017-10-01

    The housing estates in Bratislava saturated the housing needs of a large number of inhabitants who come after World War II to the city. Design of public spaces often did not have priority in the process of designing. The solutions for mentioned exterior spaces had been planned after blocks of flat realization, but many of them are not realized to this day. The article analyzes the example of the unrealized public spaces in existing housing estates Devinska Nova Ves and Petržalka (city districts of Bratislava) and offer practical solutions in relation to residencialization method. Residencialization of missing public places is an effective method of adding identities to settlements. It improves the quality of residential environment and public spaces. The main aim is to create better conditions for social activities in public areas, which are missing on the present. The research will be focused on the examination of the urban, cultural and construction potential of the existing residential enviroment in Bratislava. The main aim of residentialization is not only to enhance the quality of spatial and building structures in the selected residential area and maintain long-term sustainability in the pertinent programme area, but mainly to improve the quality of living for the residents. The outputs of the project are proposals and practical procedures developed with regard to planning documents for local municipal authorities and regional organizations. The solutions will have a positive impact on the enhancement of the quality of public spaces, attractive social activities and of a conceptual link - residentialization.

  18. Remote residential photovoltaic systems in British Columbia: A study

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, R B

    1989-01-01

    A survey of existing residential photovoltaic power systems in remote areas in British Columbia was conducted to collect data on system performance. The 80 respondents had systems with arrays ranging from 5 to 875 watts, costing from $200 to $14,000. An overwhelming majority of users expressed overall satisfaction with the contribution of photovoltaic technology to their life style. Specific advantages of photovoltaic systems over alternative energy sources included cost-effectiveness, low maintenance, lack of noise and pollution, and ease of operation. Problems with the systems included low winter power, unsatisfactory load matching, and improper operation of associated battery storage systems. It was noted that load profile estimation and system sizing calculations are difficult because control over user behavior with respect to the power system is nearly non-existent when compared to industrial installations. Low-level ampere-hour monitoring of 10 representative sites was carried out and results are presented, giving the power contributions of the photovoltaic system along with any backup system that may be present. Remote residential photovoltaic systems should continue to gain acceptance and more widespread use, especially as module costs drop and more efficient loads (especially appliances such as refrigerators) become practical. 10 figs., 2 tabs.

  19. Preliminary Electrochemical Characterization of Anode Supported Solid Oxide Cell (AS-SOC) Produced in the Institute of Power Engineering Operated in Electrolysis Mode (SOEC)

    Science.gov (United States)

    Kupecki, Jakub; Motyliński, Konrad; Skrzypkiewicz, Marek; Wierzbicki, Michał; Naumovich, Yevgeniy

    2017-12-01

    The article discusses the operation of solid oxide electrochemical cells (SOC) developed in the Institute of Power Engineering as prospective key components of power-to-gas systems. The fundamentals of the solid oxide cells operated as fuel cells (SOFC - solid oxide fuel cells) and electrolysers (SOEC - solid oxide fuel cells) are given. The experimental technique used for electrochemical characterization of cells is presented. The results obtained for planar cell with anodic support are given and discussed. Based on the results, the applicability of the cells in power-to-gas systems (P2G) is evaluated.

  20. Standard guide for mechanical drive systems for remote operation in hot cell facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Intent: 1.1.1 The intent of this standard is to provide general guidelines for the design, selection, quality assurance, installation, operation, and maintenance of mechanical drive systems used in remote hot cell environments. The term mechanical drive systems used herein, encompasses all individual components used for imparting motion to equipment systems, subsystems, assemblies, and other components. It also includes complete positioning systems and individual units that provide motive power and any position indicators necessary to monitor the motion. 1.2 Applicability: 1.2.1 This standard is intended to be applicable to equipment used under one or more of the following conditions: 1.2.1.1 The materials handled or processed constitute a significant radiation hazard to man or to the environment. 1.2.1.2 The equipment will generally be used over a long-term life cycle (for example, in excess of two years), but equipment intended for use over a shorter life cycle is not excluded. 1.2.1.3 The ...

  1. Characterization of wastewater treatment by two microbial fuel cells in continuous flow operation.

    Science.gov (United States)

    Kubota, Keiichi; Watanabe, Tomohide; Yamaguchi, Takashi; Syutsubo, Kazuaki

    2016-01-01

    A two serially connected single-chamber microbial fuel cell (MFC) was applied to the treatment of diluted molasses wastewater in a continuous operation mode. In addition, the effect of series and parallel connection between the anodes and the cathode on power generation was investigated experimentally. The two serially connected MFC process achieved 79.8% of chemical oxygen demand removal and 11.6% of Coulombic efficiency when the hydraulic retention time of the whole process was 26 h. The power densities were 0.54, 0.34 and 0.40 W m(-3) when electrodes were in individual connection, serial connection and parallel connection modes, respectively. A high open circuit voltage was obtained in the serial connection. Power density decreased at low organic loading rates (OLR) due to the shortage of organic matter. Power generation efficiency tended to decrease as a result of enhancement of methane fermentation at high OLRs. Therefore, high power density and efficiency can be achieved by using a suitable OLR range.

  2. Integrating UF6 Cylinder RF Tracking With Continuous Load Cell Monitoring for Verifying Declared UF6 Feed and Withdrawal Operations Verifying Declared UF6 Feed and Withdrawal Operations

    International Nuclear Information System (INIS)

    Krichinsky, Alan M.; Miller, Paul; Pickett, Chris A.; Richardson, Dave; Rowe, Nathan C.; Whitaker, J. Michael; Younkin, James R.

    2009-01-01

    Oak Ridge National Laboratory is demonstrating the integration of UF6 cylinder tracking, using RF technology, with continuous load cell monitoring (CLCM) at mock UF6 feed and withdrawal (F and W) stations. CLCM and cylinder tracking are two of several continuous-monitoring technologies that show promise in providing integrated safeguards of F and W operations at enrichment plants. Integrating different monitoring technologies allows advanced, automated event processing to screen innocuous events thereby minimizing false alerts to independent inspectors. Traditionally, international inspectors rely on batch verification of material inputs and outputs derived from operator declarations and periodic on-site inspections at uranium enrichment plants or other nuclear processing facilities. Continuously monitoring F and W activities between inspections while providing filtered alerts of significant operational events will substantially increase the amount of valuable information available to inspectors thereby promising to enhance the effectiveness of safeguards and to improve efficiency in conducting on-site inspections especially at large plants for ensuring that all operations are declared.

  3. Store-Operated Calcium Entries Control Neural Stem Cell Self-Renewal in the Adult Brain Subventricular Zone.

    Science.gov (United States)

    Domenichini, Florence; Terrié, Elodie; Arnault, Patricia; Harnois, Thomas; Magaud, Christophe; Bois, Patrick; Constantin, Bruno; Coronas, Valérie

    2018-05-01

    The subventricular zone (SVZ) is the major stem cell niche in the brain of adult mammals. Within this region, neural stem cells (NSC) proliferate, self-renew and give birth to neurons and glial cells. Previous studies underlined enrichment in calcium signaling-related transcripts in adult NSC. Because of their ability to mobilize sustained calcium influxes in response to a wide range of extracellular factors, store-operated channels (SOC) appear to be, among calcium channels, relevant candidates to induce calcium signaling in NSC whose cellular activities are continuously adapted to physiological signals from the microenvironment. By Reverse Transcription Polymerase Chain Reaction (RT-PCR), Western blotting and immunocytochemistry experiments, we demonstrate that SVZ cells express molecular actors known to build up SOC, namely transient receptor potential canonical 1 (TRPC1) and Orai1, as well as their activator stromal interaction molecule 1 (STIM1). Calcium imaging reveals that SVZ cells display store-operated calcium entries. Pharmacological blockade of SOC with SKF-96365 or YM-58483 (also called BTP2) decreases proliferation, impairs self-renewal by shifting the type of SVZ stem cell division from symmetric proliferative to asymmetric, thereby reducing the stem cell population. Brain section immunostainings show that TRPC1, Orai1, and STIM1 are expressed in vivo, in SOX2-positive SVZ NSC. Injection of SKF-96365 in brain lateral ventricle diminishes SVZ cell proliferation and reduces the ability of SVZ cells to form neurospheres in vitro. The present study combining in vitro and in vivo approaches uncovers a major role for SOC in the control of SVZ NSC population and opens new fields of investigation for stem cell biology in health and disease. Stem Cells 2018;36:761-774. © AlphaMed Press 2018.

  4. Estimation of energy efficiency of residential buildings

    Directory of Open Access Journals (Sweden)

    Glushkov Sergey

    2017-01-01

    Full Text Available Increasing energy performance of the residential buildings by means of reducing heat consumption on the heating and ventilation is the last segment in the system of energy resources saving. The first segments in the energy saving process are heat producing and transportation over the main lines and outside distribution networks. In the period from 2006 to 2013. by means of the heat-supply schemes optimization and modernization of the heating systems. using expensive (200–300 $US per 1 m though hugely effective preliminary coated pipes. the economy reached 2.7 mln tons of fuel equivalent. Considering the multi-stage and multifactorial nature (electricity. heat and water supply of the residential sector energy saving. the reasonable estimate of the efficiency of the saving of residential buildings energy should be performed in tons of fuel equivalent per unit of time.

  5. Residential neighbourhoods in Kathmandu: Key design guidelines

    Directory of Open Access Journals (Sweden)

    Bijaya K. Shrestha

    2013-01-01

    Full Text Available Residential neighbourhoods developed using various techniques in Kathmandu by both the public and private sectors have not only provided a poor urban setting and failed to address socio-cultural needs, but are also poor at building a community and creating links to the built environment, with the result that the planned areas lack a sense of place and the inhabitants lack a feeling of home. Although traditional neighbourhoods in the historic core area had many features of a good residential neighbourhood in the past, they are currently undergoing rapid destruction. The residents of these neighbourhoods have little awareness of these issues. The existing legal and institutional frameworks are inadequate and ineffective and cannot address these problems, and so the formulation of design guidelines, their strict implementation, and enhancement of socio-cultural events including social networking are recommended for future residential neighbourhood development.

  6. Gentrification and Residential Mobility in Philadelphia.

    Science.gov (United States)

    Ding, Lei; Hwang, Jackelyn; Divringi, Eileen

    2016-11-01

    Gentrification has provoked considerable controversy surrounding its effects on residential displacement. Using a unique individual-level, longitudinal data set, this study examines mobility rates and residential destinations of residents in gentrifying neighborhoods during the recent housing boom and bust in Philadelphia for various strata of residents and different types of gentrification. We find that vulnerable residents, those with low credit scores and without mortgages, are generally no more likely to move from gentrifying neighborhoods compared with their counterparts in nongentrifying neighborhoods. When they do move, however, they are more likely to move to lower-income neighborhoods. Residents in gentrifying neighborhoods at the aggregate level have slightly higher mobility rates, but these rates are largely driven by more advantaged residents. These findings shed new light on the heterogeneity in mobility patterns across residents in gentrifying neighborhoods and suggest that researchers should focus more attention on the quality of residential moves and nonmoves for less advantaged residents, rather than mobility rates alone.

  7. Expressions of Prayer in Residential Care Homes.

    Science.gov (United States)

    Reimer-Kirkham, Sheryl; Sharma, Sonya; Smith, Brenda; Schutt, Kelly; Janzen, Kyla

    2018-01-01

    Although the value of spiritual care in the care of older adults is supported by research, few studies have focused specifically on prayer in residential care settings. This ethnographic study with fifteen chaplains and administrators in eleven residential care homes involved analyses of walking interviews and research diaries. Findings revealed the spaces in which prayer happens and the forms it takes. The identities of chaplains-their own spiritual practices, religious beliefs, and positioning within the facility-shaped their dis/comfort with prayer and how they located prayer within public and private spaces. Where organizational leadership endorsed the legitimacy of chaplaincy services, prayer was more likely to be offered. Even in these circumstances, however, religious diversity and questions about secularism left chaplains ambivalent about the appropriateness of prayer. The results demonstrate the relevance of religion and spirituality to residential care, and illustrate how prayer functions as an opportunity for connection and understanding.

  8. Service Differentiation in Residential Broadband Networks

    DEFF Research Database (Denmark)

    Sigurdsson, Halldór Matthias

    2004-01-01

    As broadband gains widespread adoption with residential users, revenue generating voice- and video-services have not yet taken off. This slow uptake is often attributed to lack of Quality of Service management in residential broadband networks. To resolve this and induce service variety, network...... access providers are implementing service differentiation in their networks where voice and video gets prioritised before data. This paper discusses the role of network access providers in multipurpose packet based networks and the available migration strategies for supporting multimedia services...... in digital subscriber line (DSL) based residential broadband networks. Four possible implementation scenarios and their technical characteristics and effects are described. To conclude, the paper discusses how network access providers can be induced to open their networks for third party service providers....

  9. Solar Photovoltaic Financing: Residential Sector Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.; Cory, K.

    2009-03-01

    This report presents the information that homeowners and policy makers need to facilitate PV financing at the residential level. The full range of cash payments, bill savings, and tax incentives is covered, as well as potentially available solar attribute payments. Traditional financing is also compared to innovative solutions, many of which are borrowed from the commercial sector. Together, these mechanisms are critical for making the economic case for a residential PV installation, given its high upfront costs. Unfortunately, these programs are presently limited to select locations around the country. By calling attention to these innovative initiatives, this report aims to help policy makers consider greater adoption of these models to benefit homeowners interested installing a residential PV system.

  10. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  11. Residential Radon Exposure and Skin Cancer Incidence in a Prospective Danish Cohort

    DEFF Research Database (Denmark)

    Brauner, Elvira Vaclavik; Loft, Steffen; Sørensen, Mette

    2015-01-01

    Background Although exposure to UV radiation is the major risk factor for skin cancer, theoretical models suggest that radon exposure can contribute to risk, and this is supported by ecological studies. We sought to confirm or refute an association between long-term exposure to residential radon...... and the risk for malignant melanoma (MM) and non-melanoma skin cancer (NMSC) using a prospective cohort design and long-term residential radon exposure. Methods During 1993-1997, we recruited 57,053 Danish persons and collected baseline information. We traced and geocoded all residential addresses...... exposure may contribute to development of basal cell carcinoma of the skin. We cannot exclude confounding from sunlight and cannot conclude on causality, as the relationship was stronger amongst persons living in apartments and nonexistent amongst those living in single detached homes....

  12. Modelling and forecasting Turkish residential electricity demand

    International Nuclear Information System (INIS)

    Dilaver, Zafer; Hunt, Lester C

    2011-01-01

    This research investigates the relationship between Turkish residential electricity consumption, household total final consumption expenditure and residential electricity prices by applying the structural time series model to annual data over the period from 1960 to 2008. Household total final consumption expenditure, real energy prices and an underlying energy demand trend are found to be important drivers of Turkish residential electricity demand with the estimated short run and the long run total final consumption expenditure elasticities being 0.38 and 1.57, respectively, and the estimated short run and long run price elasticities being -0.09 and -0.38, respectively. Moreover, the estimated underlying energy demand trend, (which, as far as is known, has not been investigated before for the Turkish residential sector) should be of some benefit to Turkish decision makers in terms of energy planning. It provides information about the impact of past policies, the influence of technical progress, the impacts of changes in consumer behaviour and the effects of changes in economic structure. Furthermore, based on the estimated equation, and different forecast assumptions, it is predicted that Turkish residential electricity demand will be somewhere between 48 and 80 TWh by 2020 compared to 40 TWh in 2008. - Research highlights: → Estimated short run and long run expenditure elasticities of 0.38 and 1.57, respectively. → Estimated short run and long run price elasticities of -0.09 and -0.38, respectively. → Estimated UEDT has increasing (i.e. energy using) and decreasing (i.e. energy saving) periods. → Predicted Turkish residential electricity demand between 48 and 80 TWh in 2020.

  13. Action dependent heuristic dynamic programming based residential energy scheduling with home energy inter-exchange

    International Nuclear Information System (INIS)

    Xu, Yancai; Liu, Derong; Wei, Qinglai

    2015-01-01

    Highlights: • The algorithm is developed in the two-household energy management environment. • We develop the absent energy penalty cost for the first time. • The algorithm has ability to keep adapting in real-time operations. • Its application can lower total costs and achieve better load balancing. - Abstract: Residential energy scheduling is a hot topic nowadays in the background of energy saving and environmental protection worldwide. To achieve this objective, a new residential energy scheduling algorithm is developed for energy management, based on action dependent heuristic dynamic programming. The algorithm works under the circumstance of residential real-time pricing and two adjacent housing units with energy inter-exchange, which can reduce the overall cost and enhance renewable energy efficiency after long-term operation. It is designed to obtain the optimal control policy to manage the directions and amounts of electricity energy flux. The algorithm’s architecture is mainly constructed based on neural networks, denoting the learned characteristics in the linkage of layers. To get close to real situations, many constraints such as maximum charging/discharging power of batteries are taken into account. The absent energy penalty cost is developed for the first time as a part of the performance index function. When the environment changes, the residential energy scheduling algorithm gains new features and keeps adapting in real-time operations. Simulation results show that the developed algorithm is beneficial to energy conversation

  14. Strategy Guideline: High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J.

    2012-02-01

    The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

  15. Feasibility study on combined use of residential SOFC cogeneration system and plug-in hybrid electric vehicle from energy-saving viewpoint

    International Nuclear Information System (INIS)

    Wakui, Tetsuya; Wada, Naohiro; Yokoyama, Ryohei

    2012-01-01

    Highlights: ► Optimal operational planning for combined use of SOFC-CGS and PHEV is conducted. ► Charging PHEV with SOFC-CGS increases electric capacity factor of SOFC-CGS. ► Energy-saving effect of combined use is higher than that of their separate use. ► Combined use provides energy savings in both residential and transport sectors. - Abstract: The energy-saving effect of a combined use of a residential solid oxide fuel cell cogeneration system (SOFC-CGS) that adopts a continuous operation, and a plug-in hybrid electric vehicle (PHEV) is discussed by optimal operational planning based on mixed-integer linear programming. This combined use aims to increase the electric capacity factor of the SOFC-CGS by charging the PHEV using the SOFC-CGS electric power output late at night, and targets the application in regions where the reverse power flow from residential cogeneration systems to commercial electric power systems is not permitted, like in Japan. The optimal operation patterns of the combined use of 0.7-kWe SOFC-CGS and PHEV for a simulated energy demand with a sampling time of 1 h and various daily running distances of the PHEV show that this combined use increases the electric capacity factor of the SOFC-CGS and saves more energy in comparison with their separate use in which the SOFC-CGS is used but the PHEV is charged only with purchased electric power. Furthermore, it is found that at the PHEV daily running distance of 12 km/d, the reduction rate of the annual primary energy consumption for this combined use increases by up to 3.7 percentage points relative to their separate use. Consequently, this feasibility study reveals that the combined use of the SOFC-CGS and PHEV provides the synergistic effect on energy savings in the residential and transport sectors. For the practical use, simulation scenarios considering the energy demand fluctuations with short periods and real-time pricing of the purchased electric power must be considered as future

  16. A thermodynamic approach for selecting operating conditions in the design of reversible solid oxide cell energy systems

    Science.gov (United States)

    Wendel, Christopher H.; Kazempoor, Pejman; Braun, Robert J.

    2016-01-01

    Reversible solid oxide cell (ReSOC) systems are being increasingly considered for electrical energy storage, although much work remains before they can be realized, including cell materials development and system design optimization. These systems store electricity by generating a synthetic fuel in electrolysis mode and subsequently recover electricity by electrochemically oxidizing the stored fuel in fuel cell mode. System thermal management is improved by promoting methane synthesis internal to the ReSOC stack. Within this strategy, the cell-stack operating conditions are highly impactful on system performance and optimizing these parameters to suit both operating modes is critical to achieving high roundtrip efficiency. Preliminary analysis shows the thermoneutral voltage to be a useful parameter for analyzing ReSOC systems and the focus of this study is to quantitatively examine how it is affected by ReSOC operating conditions. The results reveal that the thermoneutral voltage is generally reduced by increased pressure, and reductions in temperature, fuel utilization, and hydrogen-to-carbon ratio. Based on the thermodynamic analysis, many different combinations of these operating conditions are expected to promote efficient energy storage. Pressurized systems can achieve high efficiency at higher temperature and fuel utilization, while non-pressurized systems may require lower stack temperature and suffer from reduced energy density.

  17. Receiver-operating characteristic curves for somatic cell scores and California mastitis test in Valle del Be lice dairy sheep

    NARCIS (Netherlands)

    Riggio, V.; Pesce, L.L.; Morreale, S.; Portolano, B.

    2013-01-01

    Using receiver-operating characteristic (ROC) curve methodology this study was designed to assess the diagnostic effectiveness of somatic cell count (SCC) and the California mastitis test (CMT) in Valle del Belice sheep, and to propose and evaluate threshold values for those tests that would

  18. Heat and fuel coupled operation of a high temperature polymer electrolyte fuel cell with a heat exchanger methanol steam reformer

    Science.gov (United States)

    Schuller, G.; Vázquez, F. Vidal; Waiblinger, W.; Auvinen, S.; Ribeirinha, P.

    2017-04-01

    In this work a methanol steam reforming (MSR) reactor has been operated thermally coupled to a high temperature polymer electrolyte fuel cell stack (HT-PEMFC) utilizing its waste heat. The operating temperature of the coupled system was 180 °C which is significantly lower than the conventional operating temperature of the MSR process which is around 250 °C. A newly designed heat exchanger reformer has been developed by VTT (Technical Research Center of Finland LTD) and was equipped with commercially available CuO/ZnO/Al2O3 (BASF RP-60) catalyst. The liquid cooled, 165 cm2, 12-cell stack used for the measurements was supplied by Serenergy A/S. The off-heat from the electrochemical fuel cell reaction was transferred to the reforming reactor using triethylene glycol (TEG) as heat transfer fluid. The system was operated up to 0.4 A cm-2 generating an electrical power output of 427 Wel. A total stack waste heat utilization of 86.4% was achieved. It has been shown that it is possible to transfer sufficient heat from the fuel cell stack to the liquid circuit in order to provide the needed amount for vaporizing and reforming of the methanol-water-mixture. Furthermore a set of recommendations is given for future system design considerations.

  19. Long-term operation of a solid oxide cell stack for coelectrolysis of steam and CO2

    DEFF Research Database (Denmark)

    Agersted, Karsten; Chen, Ming; Blennow, Peter

    2016-01-01

    of synthetic fuels such as methane, methanol or DME. Previously we have reported electrolysis operation of solid oxide cell stacks for periods up to about 1000 hours. In this work, operation of a Haldor Topsoe 8-cell stack (stack design of 2014) in co-electrolysis mode for 6000 hours is reported. The stack....... Initial operation at 700 oC and -0.25 A/cm2 lasted for only 120 hours due to severe degradation of the bottom cell. Regaining the stack performance was realized by increasing the operation temperature to 750 oC. After reactivation, the stack showed negligible degradation at 750 oC and -0.25 A/cm2...... and about 1.4 %/1000 h performance degradation at 750 oC and -0.5 A/cm2. This study demonstrates feasibility of long-term co-electrolysis operation via SOEC stacks and of careful temperature variation as a tool to regain the stack performance....

  20. Sustainable residential districts : the residents' role in project success

    NARCIS (Netherlands)

    Abdalla, G.

    2012-01-01

    Sustainable residential districts have been realized worldwide. These districts are promoted to be efficient in the use of natural materials and sustainable energy resources. Realization of sustainable residential districts can strongly contribute to achieve environmental objectives as imposed by

  1. PRN 2011-1: Residential Exposure Joint Venture

    Science.gov (United States)

    This PR Notice is to advise registrants of an industry-wide joint venture, titled the Residential Exposure Joint Venture (REJV), which has developed a national survey regarding residential consumer use/usage data for pesticides.

  2. Steering Angle Function Algorithm of Morphing of Residential Area

    Directory of Open Access Journals (Sweden)

    XIE Tian

    2015-07-01

    Full Text Available A residential area feature morphing method based on steering angle function is presented. To residential area with the same representation under two different scales,transforming the representation of the residential area polygon from vector coordinates to steering angle function,then using the steering angle function to match,and finding out the similarity and the differences between the residential areas under different scale to get the steering angle function of the the residential areas under any middle scale,the final,transforming the middle scale steering angle function to vector coordinates form,and get the middle shape interpolation of the the residential area polygon.Experimental results show:the residential area morphing method by using steering angle function presented can realize the continuous multi-scale representation under the premise of keeping in shape for the residential area with the rectangular boundary features.

  3. Spatial Operations

    Directory of Open Access Journals (Sweden)

    Anda VELICANU

    2010-09-01

    Full Text Available This paper contains a brief description of the most important operations that can be performed on spatial data such as spatial queries, create, update, insert, delete operations, conversions, operations on the map or analysis on grid cells. Each operation has a graphical example and some of them have code examples in Oracle and PostgreSQL.

  4. A microfluidic-structured flow field for passive direct methanol fuel cells operating with highly concentrated fuels

    International Nuclear Information System (INIS)

    Wu, Q X; Zhao, T S; Chen, R; Yang, W W

    2010-01-01

    Conventional direct methanol fuel cells (DMFCs) have to operate with excessively diluted methanol solutions to limit methanol crossover and its detrimental consequences. Operation with such diluted methanol solutions not only results in a significant penalty in the specific energy of the power pack, limiting the runtime of this type of fuel cell, but also lowers the cell performance and operating stability. In this paper, a microfluidic-structured anode flow field for passive DMFCs with neither liquid pumps nor gas compressors/blowers is developed. This flow field consists of plural micro flow passages. Taking advantage of the liquid methanol and gas CO 2 two-phase counter flow, the unique fluidic structure enables the formation of a liquid–gas meniscus in each flow passage. The evaporation from the small meniscus in each flow passage can lead to an extremely large interfacial mass-transfer resistance, creating a bottleneck of methanol delivery to the anode CL. The fuel cell tests show that the innovative flow field allows passive DMFCs to achieve good cell performance with a methanol concentration as high as 18.0 M, increasing the specific energy of the DMFC system by about five times compared with conventional designs.

  5. Density functional theory calculations of H/D isotope effects on polymer electrolyte membrane fuel cell operations

    Energy Technology Data Exchange (ETDEWEB)

    Yanase, Satoshi; Oi, Takao [Sophia Univ., Tokyo (Japan). Faculty of Science and Technology

    2015-10-01

    To elucidate hydrogen isotope effects observed between fuel and exhaust hydrogen gases during polymer electrolyte membrane fuel cell operations, H-to-D reduced partition function ratios (RPFRs) for the hydrogen species in the Pt catalyst phase of the anode and the electrolyte membrane phase of the fuel cell were evaluated by density functional theory calculations on model species of the two phases. The evaluation yielded 3.2365 as the value of the equilibrium constant of the hydrogen isotope exchange reaction between the two phases at 39 C, which was close to the experimentally estimated value of 3.46-3.99 at the same temperature. It was indicated that H{sup +} ions on the Pt catalyst surface of the anode and H species in the electrolyte membrane phase were isotopically in equilibrium with one another during fuel cell operations.

  6. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  7. Suggestions on Strengthening Greening Construction of Ecological Residential Areas

    OpenAIRE

    Li, Peng

    2013-01-01

    Greening construction is an important part of the construction of ecological residential areas, but there exist some misunderstandings in greening construction of ecological residential districts at present. Based on the description of functions of green space in ecological residential areas, the summarization of principles of greening design, and the discussion of questions in greening construction of ecological residential districts, some suggestions as well as specific measures for strengt...

  8. Impact of fuel cell power plants on multi-objective optimal operation management of distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, T. [Electrical and Electronic Engineering Department, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Zeinoddini-Meymand, H. [Islamic Azad University, Kerman Branch, Kerman (Iran, Islamic Republic of)

    2012-06-15

    This paper presents an interactive fuzzy satisfying method based on hybrid modified honey bee mating optimization and differential evolution (MHBMO-DE) to solve the multi-objective optimal operation management (MOOM) problem, which can be affected by fuel cell power plants (FCPPs). The objective functions are to minimize total electrical energy losses, total electrical energy cost, total pollutant emission produced by sources, and deviation of bus voltages. A new interactive fuzzy satisfying method is presented to solve the multi-objective problem by assuming that the decision-maker (DM) has fuzzy goals for each of the objective functions. Through the interaction with the DM, the fuzzy goals of the DM are quantified by eliciting the corresponding membership functions. Then, by considering the current solution, the DM acts on this solution by updating the reference membership values until the satisfying solution for the DM can be obtained. The MOOM problem is modeled as a mixed integer nonlinear programming problem. Evolutionary methods are used to solve this problem because of their independence from type of the objective function and constraints. Recently researchers have presented a new evolutionary method called honey bee mating optimization (HBMO) algorithm. Original HBMO often converges to local optima, in order to overcome this shortcoming, we propose a new method that improves the mating process and also, combines the modified HBMO with DE algorithm. Numerical results for a distribution test system have been presented to illustrate the performance and applicability of the proposed method. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. CD117 expression in operable oesophageal squamous cell carcinomas predicts worse clinical outcome

    Science.gov (United States)

    Fan, Huijie; Yuan, Yuan; Wang, Junsheng; Zhou, Fuyou; Zhang, Mingzhi; Giercksky, Karl-Erik; Nesland, Jahn M; Suo, Zhenhe

    2013-01-01

    Aims To investigate the aberrant expression of CD117 in oesophageal squamous cell carcinoma (SCC) and its prognostic significance. Methods and results Immunohistochemical staining for CD117 was performed on tissue microarray and routine tissue sections from 157 oesophageal SCC patients and 10 normal oesophageal epithelia adjacent to tumour. The positive rate of CD117 expression was 29.9% in oesophageal SCC tissues, whereas no CD117 expression was detected in the 10 normal oesophageal epithelia. CD117 expression was significantly associated with T stage (P < 0.001), distant metastasis (P = 0.015), lymph node metastasis (P = 0.019), and clinical stage (P = 0.021). Progression-free survival in the patients with CD117-positive tumours was shorter than that in the patients with CD117-negative tumours (P = 0.010). In univariate analyses, CD117 expression was the most significant factor for overall survival of oesophageal SCC patients (P < 0.001), followed by lymph node metastasis (P = 0.001), T stage (P = 0.002), clinical stage (P = 0.006), distant metastasis (P = 0.020), and histological grade (P = 0.027). Multivariate analyses verified that CD117 expression was an independent prognostic marker for oesophageal SCC patients (P = 0.002). In addition, CD117 expression predicted poorer survival in patients without distant metastases. Conclusions CD117 expression in operable oesophageal SCC may be a valuable prognostic marker, and detection of its expression in clinical samples may be useful in defining a subclass of oesophageal SCCs with extremely poor clinical outcome, which may require a specially targeted treatment modality. PMID:23570416

  10. Operation optimization of distributed generation using artificial intelligent techniques

    Directory of Open Access Journals (Sweden)

    Mahmoud H. Elkazaz

    2016-06-01

    Full Text Available Future smart grids will require an observable, controllable and flexible network architecture for reliable and efficient energy delivery. The use of artificial intelligence and advanced communication technologies is essential in building a fully automated system. This paper introduces a new technique for online optimal operation of distributed generation (DG resources, i.e. a hybrid fuel cell (FC and photovoltaic (PV system for residential applications. The proposed technique aims to minimize the total daily operating cost of a group of residential homes by managing the operation of embedded DG units remotely from a control centre. The target is formed as an objective function that is solved using genetic algorithm (GA optimization technique. The optimal settings of the DG units obtained from the optimization process are sent to each DG unit through a fully automated system. The results show that the proposed technique succeeded in defining the optimal operating points of the DGs that affect directly the total operating cost of the entire system.

  11. 24 CFR 40.2 - Definition of “residential structure”.

    Science.gov (United States)

    2010-04-01

    ... OWNED RESIDENTIAL STRUCTURES § 40.2 Definition of “residential structure”. (a) As used in this part, the term residential structure means a residential structure (other than a privately owned residential structure and a residential structure on a military reservation): (1) Constructed or altered by or on behalf...

  12. Residential Preferences and Moving Behavior: A Family Life Cycle Analysis.

    Science.gov (United States)

    McAuley, William J.; Nutty, Cheri L.

    The relationship of family life cycle changes to housing preferences and residential mobility is examined. Two residential decision-making issues are explored in detail--how family life cycle stages influence what people view as important to their choice of residential setting and what individuals at different family life cycle stages view as the…

  13. 38 CFR 36.4357 - Combination residential and business property.

    Science.gov (United States)

    2010-07-01

    ... Reporting § 36.4357 Combination residential and business property. If otherwise eligible, a loan for the purchase or construction of a combination of residential property and business property which the veteran... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Combination residential...

  14. Family events and the residential mobility of couples

    NARCIS (Netherlands)

    Michielin, F.; Mulder, C.H.

    2008-01-01

    Using data from retrospective surveys carried out in the Netherlands during the early 1990s, we describe how the residential mobility of couples—that is, short-distance moves—is affected by family events and how fertility is affected by residential mobility. The results show that residential moves

  15. Series vs parallel connected organic tandem solar cells : cell performance and impact on the design and operation of functional modules

    NARCIS (Netherlands)

    Etxebarriaa, I.; Furlan, A.; Ajuria, J.; Fecher, F.W.; Voigt, de M.J.A.; Brabecd, C.J.; Wienk, M.M.; Slooff, L.H.; Veenstra, S.; Gilot, J.; Pacios, R.

    2014-01-01

    Tandem solar cells are the best approach to maximize the light harvesting and adjust the overall absorption of the cell to the solar irradiance spectrum. Usually, the front and back subcells are connected in series in two-terminal device (2T) designs which require a current matching between both

  16. Micro-CHP Systems for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Timothy DeValve; Benoit Olsommer

    2007-09-30

    products, mostly in Europe, and it is urgent to react promptly to these offerings that will soon emerge on the U.S. market as well. For all these reasons, UTC urges the U.S. Department of Energy to fund the Phase II Development Program in the nation's interest. The objective of this study of micro-CHP systems was to establish strategies for development, demonstration, and sustainable commercialization of cost-effective integrated Cooling, Heating and Power (CHP) systems for residential applications. Successful commercialization will ultimately involve component suppliers both for the micro-CHP system, and for the building electric power, heating, cooling, ventilation, and hot water supply systems. All of these components must be compatible and integrated as a system with their safe and reliable operation coordinated by an overall supervisory control system.

  17. Effects of heat and water transport on the performance of polymer electrolyte membrane fuel cell under high current density operation

    International Nuclear Information System (INIS)

    Tabuchi, Yuichiro; Shiomi, Takeshi; Aoki, Osamu; Kubo, Norio; Shinohara, Kazuhiko

    2010-01-01

    Key challenges to the acceptance of polymer electrolyte membrane fuel cells (PEMFCs) for automobiles are the cost reduction and improvement in its power density for compactness. In order to get the solution, the further improvement in a fuel cell performance is required. In particular, under higher current density operation, water and heat transport in PEMFCs has considerable effects on the cell performance. In this study, the impact of heat and water transport on the cell performance under high current density was investigated by experimental evaluation of liquid water distribution and numerical validation. Liquid water distribution in MEA between rib and channel area is evaluated by neutron radiography. In order to neglect the effect of liquid water in gas channels and reactant species concentration distribution in the flow direction, the differential cell was used in this study. Experimental results suggested that liquid water under the channel was dramatically changed with rib/channel width. From the numerical study, it is found that the change of liquid water distribution was significantly affected by temperature distribution in MEA between rib and channel area. In addition, not only heat transport but also water transport through the membrane also significantly affected the cell performance under high current density operation.

  18. Molecular characterization of dendritic cells operating at the interface of innate or acquired immunity.

    NARCIS (Netherlands)

    Figdor, C.G.

    2003-01-01

    Dendritic Cells (DC) are natural adjuvants able to elicit specific cellular interactions and priming of naive T cells at a mature stage of their differentiation. Recent genomic approaches helped defining DC or Langherans Cells (LC) in more molecular terms. DC-SIGN, the DC specific ICAM-3 grabbing

  19. A novel poly(propylene-co-imidazole) based biofuel cell: System optimization and operation for energy generation

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Muhammet Samet [Department of Chemistry, Bulent Ecevit University, 67100 Zonguldak (Turkey); Korkut, Seyda, E-mail: s.korkut@beun.edu.tr [Department of Environmental Engineering, Bulent Ecevit University, 67100 Zonguldak (Turkey); Hazer, Baki [Department of Chemistry, Bulent Ecevit University, 67100 Zonguldak (Turkey)

    2015-02-01

    This study describes the construction of an enzymatic fuel cell comprised of novel gold nanoparticles embedded poly(propylene-co-imidazole) coated anode and cathode. Working electrode fabrication steps and operational conditions for the fuel cell have been optimized to get enhanced power output. Electrical generation capacity of the optimized cell was tested by using the municipal wastewater sample. The enzymatic fuel cell system reached to maximum power density with 1 μg and 8 μg of polymer quantity and bilirubin oxidase on electrode surface, respectively. The maximum power output was calculated to be 5 μW cm{sup −2} at + 0.56 V (vs. Ag/AgCl) in phosphate buffer (pH 7.4, 100 mM, 20 °C) by the addition of 15 mM of glucose as a fuel source. The optimized enzymatic fuel cell generated a power density of 0.46 μW cm{sup −2} for the municipal wastewater sample. Poly(propylene-co-imidazole) was easily used for a fuel cell system owing to its metallic nanoparticle content. The developed fuel cell will play a significant role for energy conversion by using glucose readily found in wastewater and in vivo mediums. - Highlights: • Gold nanoparticles provided faster electron transfer in the circuit. • The maximum power density of 5 μW cm{sup −2} was generated at + 0.56 V cell potential. • The cell can be easily operated for in vivo mediums.

  20. Hydrological processes at the urban residential scale

    Science.gov (United States)

    Q. Xiao; E.G. McPherson; J.R. Simpson; S.L. Ustin

    2007-01-01

    In the face of increasing urbanization, there is growing interest in application of microscale hydrologic solutions to minimize storm runoff and conserve water at the source. In this study, a physically based numerical model was developed to understand hydrologic processes better at the urban residential scale and the interaction of these processes among different...

  1. Does Fall History Influence Residential Adjustments?

    Science.gov (United States)

    Leland, Natalie; Porell, Frank; Murphy, Susan L.

    2011-01-01

    Purpose of the study: To determine whether reported falls at baseline are associated with an older adult's decision to make a residential adjustment (RA) and the type of adjustment made in the subsequent 2 years. Design and Methods: Observations (n = 25,036) were from the Health and Retirement Study, a nationally representative sample of…

  2. Condition assessment and strengthening of residential units

    Directory of Open Access Journals (Sweden)

    Tatheer Zahra

    2014-01-01

    Full Text Available About 40, ground plus one (G+1 residential units were designed using a hybrid structural framing system (RC frame and load bearing walls. A few months after the completion of the ground floor of the residential units, cracks appeared at several locations in the structure. Field and Laboratory testing was conducted to ascertain the in situ strength of concrete and steel reinforcement. The results of the experimental work were used in the analytical ETABS model for the structural stability calculations. The results indicated that residential units were marginally safe in the existing condition (completed ground floor, but the anticipated construction of the floor above the ground floor (G+1 could not be carried out as the strength of the structural system was inadequate. To increase the safety of existing ground floor and to provide the option of the construction of one floor above, rehabilitation and strengthening design was performed. The proposed strengthening design made use of welded wire fabric (WWF and carbon fibre reinforced polymer (CFRP laminates/sheets for the strengthening of walls, columns and slabs. The residential units will be strengthened in the near future.

  3. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  4. Employee influenza vaccination in residential care facilities.

    Science.gov (United States)

    Apenteng, Bettye A; Opoku, Samuel T

    2014-03-01

    The organizational literature on infection control in residential care facilities is limited. Using a nationally representative dataset, we examined the organizational factors associated with implementing at least 1 influenza-related employee vaccination policy/program, as well as the effect of vaccination policies on health care worker (HCW) influenza vaccine uptake in residential care facilities. The study was a cross-sectional study using data from the 2010 National Survey of Residential Care Facilities. Multivariate logistic regression analysis was used to address the study's objectives. Facility size, director's educational attainment, and having a written influenza pandemic preparedness plan were significantly associated with the implementation of at least 1 influenza-related employee vaccination policy/program, after controlling for other facility-level factors. Recommending vaccination to employees, providing vaccination on site, providing vaccinations to employees at no cost, and requiring vaccination as a condition of employment were associated with higher employee influenza vaccination rates. Residential care facilities can improve vaccination rates among employees by adopting effective employee vaccination policies. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Chapter 6: Residential Lighting Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Dimetrosky, Scott [Apex Analytics LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics LLC, Boulder, CO (United States)

    2015-02-01

    In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

  6. Residential and Light Commercial HVAC. Teacher Edition.

    Science.gov (United States)

    Stephenson, David; Fulkerson, Dan, Ed.

    This curriculum guide contains 18 units of instruction for a competency-based course in residential and light commercial heating, ventilating, and air conditioning (HVAC). Introductory materials include a competency profile and an instructional/task analysis that correlates job training with related information for this course. Each instructional…

  7. DETERMINANTS OF RESIDENTIAL PER CAPITA WATER ...

    African Journals Online (AJOL)

    This report presents the findings of the study on the determinants of residential per capita water demand of Makurdi metropolis in Benue State, Nigeria. Data for the study was obtained by the use of questionnaires, oral interviews and observations. The data was analyzed using SPSS. Twenty variables were considered in ...

  8. Consumer Decision Rules and Residential Finance.

    Science.gov (United States)

    Brandt, Jeanette A.; Jaffe, Austin J.

    1979-01-01

    As guidelines for residential financing, the authors compare different approaches to understanding and figuring the costs of home ownership: the relation of income to house price and housing costs, interest rate, and mortgage term. Instead of the traditional method, they recommend the time value of money approach. (MF)

  9. Energy Management Strategy Based on Multiple Operating States for a Photovoltaic/Fuel Cell/Energy Storage DC Microgrid

    Directory of Open Access Journals (Sweden)

    Ying Han

    2017-01-01

    Full Text Available It is a great challenge for DC microgrids with stochastic renewable sources and volatility loads to achieve better operation performance. This study proposes an energy management strategy based on multiple operating states for a DC microgrid, which is comprised of a photovoltaic (PV array, a proton exchange membrane fuel cell (PEMFC system, and a battery bank. This proposed strategy can share the power properly and keep the bus voltage steady under different operating states (the state of charge (SOC of the battery bank, loading conditions, and PV array output power. In addition, a microgrids test platform is established. In order to verify the effectiveness of the proposed energy management strategy, the strategy is implemented in a hardware system and experimentally tested under different operating states. The experimental results illustrate the good performance of the proposed control strategy for the DC microgrid under different scenarios of power generation and load demand.

  10. Modeled microgravity suppressed invasion and migration of human glioblastoma U87 cells through downregulating store-operated calcium entry

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Zi-xuan [Department of Traditional Chinese Medicine, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 (China); Rao, Wei [Department of Neurosurgery, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 (China); Wang, Huan [Department of Dermatology, Tangdu Hospital, Fourth Military Medical University, Xi' an, 710032 (China); Wang, Nan-ding [Department of Cardiology, Xi' an Traditional Chinese Medicine Hospital, Xi' an, 710032 (China); Si, Jing-Wen; Zhao, Jiao; Li, Jun-chang [Department of Traditional Chinese Medicine, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 (China); Wang, Zong-ren, E-mail: zongren@fmmu.edu.cn [Department of Traditional Chinese Medicine, Xijing Hospital, Fourth Military Medical University, Xi' an, 710032 (China)

    2015-02-13

    Glioblastoma is the most common brain tumor and is characterized with robust invasion and migration potential resulting in poor prognosis. Previous investigations have demonstrated that modeled microgravity (MMG) could decline the cell proliferation and attenuate the metastasis potential in several cell lines. In this study, we studied the effects of MMG on the invasion and migration potentials of glioblastoma in human glioblastoma U87 cells. We found that MMG stimulation significantly attenuated the invasion and migration potentials, decreased thapsigargin (TG) induced store-operated calcium entry (SOCE) and downregulated the expression of Orai1 in U87 cells. Inhibition of SOCE by 2-APB or stromal interaction molecule 1 (STIM1) downregulation both mimicked the effects of MMG on the invasion and migration potentials in U87 cells. Furthermore, upregulation of Orai1 significantly weakened the effects of MMG on the invasion and migration potentials in U87 cells. Therefore, these findings indicated that MMG stimulation inhibited the invasion and migration potentials of U87 cells by downregulating the expression of Orai1 and sequentially decreasing the SOCE, suggesting that MMG might be a new potential therapeutic strategy in glioblastoma treatment in the future. - Highlights: • Modeled microgravity (MMG) suppressed migration and invasion in U87 cells. • MMG downregulated the SOCE and the expression of Orai1. • SOCE inhibition mimicked the effects of MMG on migration and invasion potentials. • Restoration of SOCE diminished the effects of MMG on migration and invasion.

  11. Modeled microgravity suppressed invasion and migration of human glioblastoma U87 cells through downregulating store-operated calcium entry

    International Nuclear Information System (INIS)

    Shi, Zi-xuan; Rao, Wei; Wang, Huan; Wang, Nan-ding; Si, Jing-Wen; Zhao, Jiao; Li, Jun-chang; Wang, Zong-ren

    2015-01-01

    Glioblastoma is the most common brain tumor and is characterized with robust invasion and migration potential resulting in poor prognosis. Previous investigations have demonstrated that modeled microgravity (MMG) could decline the cell proliferation and attenuate the metastasis potential in several cell lines. In this study, we studied the effects of MMG on the invasion and migration potentials of glioblastoma in human glioblastoma U87 cells. We found that MMG stimulation significantly attenuated the invasion and migration potentials, decreased thapsigargin (TG) induced store-operated calcium entry (SOCE) and downregulated the expression of Orai1 in U87 cells. Inhibition of SOCE by 2-APB or stromal interaction molecule 1 (STIM1) downregulation both mimicked the effects of MMG on the invasion and migration potentials in U87 cells. Furthermore, upregulation of Orai1 significantly weakened the effects of MMG on the invasion and migration potentials in U87 cells. Therefore, these findings indicated that MMG stimulation inhibited the invasion and migration potentials of U87 cells by downregulating the expression of Orai1 and sequentially decreasing the SOCE, suggesting that MMG might be a new potential therapeutic strategy in glioblastoma treatment in the future. - Highlights: • Modeled microgravity (MMG) suppressed migration and invasion in U87 cells. • MMG downregulated the SOCE and the expression of Orai1. • SOCE inhibition mimicked the effects of MMG on migration and invasion potentials. • Restoration of SOCE diminished the effects of MMG on migration and invasion

  12. Mitochondrial Ca2+ uniporter is critical for store-operated Ca2+ entry-dependent breast cancer cell migration

    International Nuclear Information System (INIS)

    Tang, Shihao; Wang, Xubu; Shen, Qiang; Yang, Xinyi; Yu, Changhui; Cai, Chunqing; Cai, Guoshuai; Meng, Xiaojing; Zou, Fei

    2015-01-01

    Metastasis of cancer cells is a complicated multistep process requiring extensive and continuous cytosolic calcium modulation. Mitochondrial Ca 2+ uniporter (MCU), a regulator of mitochondrial Ca 2+ uptake, has been implicated in energy metabolism and various cellular signaling processes. However, whether MCU contributes to cancer cell migration has not been established. Here we examined the expression of MCU mRNA in the Oncomine database and found that MCU is correlated to metastasis and invasive breast cancer. MCU inhibition by ruthenium red (RuR) or MCU silencing by siRNA abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or thapsigargin (TG)-induced store-operated Ca2+ entry (SOCE). Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. Our results demonstrate that MCU plays a critical role in breast cancer cell migration by regulating SOCE. - Highlights: • MCU is correlated to metastasis and invasive breast cancer. • MCU inhibition abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or TG-induced SOCE. • Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. • MCU plays a critical role in MDA-MB-231 cell migration by regulating SOCE

  13. Optimal residential smart appliances scheduling considering distribution network constraints

    Directory of Open Access Journals (Sweden)

    Yu-Ree Kim

    2016-01-01

    Full Text Available As smart appliances (SAs are more widely adopted within distribution networks, residential consumers can contribute to electricity market operations with demand response resources and reduce their electricity bill. However, if the schedules of demand response resources are determined only by the economic electricity rate signal, the schedule can be unfeasible due to the distribution network constraints. Furthermore, it is impossible for consumers to understand the complex physical characteristics and reflect them in their everyday behaviors. This paper introduces the concept of load coordinating retailer (LCR that deals with demand responsive appliances to reduce electrical consumption for the given distribution network constraints. The LCR can play the role of both conventional retailer and aggregated demand response provider for residential customers. It determines the optimal schedules for the aggregated neighboring SAs according to their types within each distribution feeder. The optimization algorithms are developed using Mixed Integer Linear Programming, and the distribution network is solved by the Newton–Raphson AC power flow.

  14. Expanded BPA residential weatherization program: summary of regional health effects

    International Nuclear Information System (INIS)

    Sandusky, W.F.; Thor, P.W.; Alton, C.C.; Mellinger, P.J.; Cross, F.T.

    1984-11-01

    The Final Environmental Impact Statement (FEIS) for the Bonneville Power Administration (BPA) Expanded Residential Weatherization Program has been completed, printed, and distributed. This document incorporates numerous revisions based on both oral and written comments received during the public comment of the Draft Environmental Impact Statement (DEIS). The estimates of regional health effects were revised to incorporate results of the second Pacific Northwest Residential Energy Survey (PNWRES). The FEIS now expresses the estimated regional health effects in terms of incidence of cancers per 100,000 people exposed, which allows comparison to be made to the annual average risk of fatality by other causes. The estimates of regional health effects are also compared to health effects resulting from supplying and operating a conventional coal plant at a power level equal to the amount of energy saved from installation of additional tightening measures. Numerical results for the estimated health effects described above are provided. A summary of the comments received on the DEIS is also provided, along with estimated health effects associated with the Environmentally Preferred and BPA Preferred Alternatives to the Proposed Action. 8 refs., 3 figs., 5 tabs

  15. Accelerating residential PV expansion: supply analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Payne, Adam; Williams, Robert H.; Duke, Richard

    2001-01-01

    Photovoltaic (PV) technology is now sufficiently advanced that market support mechanisms such as net metering plus a renewable portfolio standard (RPS) could induce rapid PV market growth in grid-connected applications. With such support mechanisms, markets would be sufficiently large that manufacturers could profitably build and operate 100 MW p /yr PV module factories, and electricity costs for residential rooftop PV systems would compare favorably with residential electricity prices in certain areas (e.g., California and the greater New York region in the US). This prospect is illustrated by economic and market analyses for one promising technology (amorphous silicon thin-film PV) from the perspectives of both module manufacturers and buyers of new homes with rooftop PV systems. With public policies that reflect the distributed and environmental benefits offered by PV-and that can sustain domestic PV market demand growth at three times the historical growth rate for a period of the order of two decades - PV could provide 3% of total US electricity supply by 2025. (Author)

  16. An overview of particulate emissions from residential biomass combustion

    Science.gov (United States)

    Vicente, E. D.; Alves, C. A.

    2018-01-01

    Residential biomass burning has been pointed out as one of the largest sources of fine particles in the global troposphere with serious impacts on air quality, climate and human health. Quantitative estimations of the contribution of this source to the atmospheric particulate matter levels are hard to obtain, because emission factors vary greatly with wood type, combustion equipment and operating conditions. Updated information should improve not only regional and global biomass burning emission inventories, but also the input for atmospheric models. In this work, an extensive tabulation of particulate matter emission factors obtained worldwide is presented and critically evaluated. Existing quantifications and the suitability of specific organic markers to assign the input of residential biomass combustion to the ambient carbonaceous aerosol are also discussed. Based on these organic markers or other tracers, estimates of the contribution of this sector to observed particulate levels by receptor models for different regions around the world are compiled. Key areas requiring future research are highlighted and briefly discussed.

  17. Information Processing and Creative Thinking Abilities of Residential and Non-Residential School Children

    Directory of Open Access Journals (Sweden)

    Atasi Mohanty

    2015-10-01

    Full Text Available This study attempts to assess and compare the residential and non-residential schoolchildren in information-processing skills and creative thinking abilities. A sample of 80 children from Classes 5 and 7 were selected from two types of schools, residential/ashram (02 and non-residential/formal schools (02 in Bolpur subdivision of West Bengal in India where the medium of instruction is Bengali language/mother-tongue. All the children were individually administered the PASS (Planning, Attention, Simultaneous, Successive, Stroop, Matching Familiar Figure Test (MFFT-20, and creative thinking tasks. The residential school children were found to perform better both in information processing and creative thinking tasks. The developmental trend could not be clearly observed due to small sample size, but with increasing age, children were using better processing strategies. Due to ashram environment, creative pedagogy, and various co-curricular activities, the residential school children were found to be more creative than their formal school counterparts. Moreover, some significant positive correlations were found among information processing skills and creative thinking dimensions.

  18. Determining the market value of high-rise residential buildings based on evaluation of consumer properties

    Directory of Open Access Journals (Sweden)

    Kolobova Svetlana

    2018-01-01

    Full Text Available As you know, high-rise construction is an indicator of the practical implementation of advanced innovative technologies in the construction industry of the country. High-rise building inevitably comes to the big cities, in connection with the shortage and value of land. The life cycle of any construction project, including high-rise buildings consists of chains: of engineering survey - design-construction-operation. In the process of operation of a tall building, decisions about major repairs or reconstruction of a building are made for decision-making on further use. This article describes methods of assessing the consumer quality of high-rise residential buildings and the establishment of prices based on consumer characteristics of a tall residential building. It is proposed to assess the premises under their quality characteristics. The study was conducted to establish the influence of individual, comprehensive and integral indicators of comparable quality for effective quality living spaces. Simultaneously, there was established a relationship of quality with the consumer cost of housing, ultimately with the potential needs of owners, tenants of the home, lessor dwelling, or buyers of residential properties and other participants in the residential real estate market. This relationship further creates consumer requirements to quality standard of premises at a certain stage of socio-economic development.

  19. Determining the market value of high-rise residential buildings based on evaluation of consumer properties

    Science.gov (United States)

    Kolobova, Svetlana

    2018-03-01

    As you know, high-rise construction is an indicator of the practical implementation of advanced innovative technologies in the construction industry of the country. High-rise building inevitably comes to the big cities, in connection with the shortage and value of land. The life cycle of any construction project, including high-rise buildings consists of chains: of engineering survey - design-construction-operation. In the process of operation of a tall building, decisions about major repairs or reconstruction of a building are made for decision-making on further use. This article describes methods of assessing the consumer quality of high-rise residential buildings and the establishment of prices based on consumer characteristics of a tall residential building. It is proposed to assess the premises under their quality characteristics. The study was conducted to establish the influence of individual, comprehensive and integral indicators of comparable quality for effective quality living spaces. Simultaneously, there was established a relationship of quality with the consumer cost of housing, ultimately with the potential needs of owners, tenants of the home, lessor dwelling, or buyers of residential properties and other participants in the residential real estate market. This relationship further creates consumer requirements to quality standard of premises at a certain stage of socio-economic development.

  20. Intra-operative cell salvage and sickle cell trait in liver transplantation: time to re-consider?

    Science.gov (United States)

    Loh, P S; Gilder, F; Klinck, J

    2018-04-19

    Sickle cell trait (SCT), characterized by the sickle hemoglobin (HbS) gene in a heterozygous state is the most common hemoglobinopathy worldwide that is typically asymptomatic in affected individuals [1]. In Europe, migration has increased the prevalence, raising concerns about its clinical impact [1]. For example, the use of intraoperative cell salvage may induce sickling because of hypoxia during processing [2]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Impact of residential schooling and of child abuse on substance use problem in Indigenous Peoples.

    Science.gov (United States)

    Ross, Amélie; Dion, Jacinthe; Cantinotti, Michael; Collin-Vézina, Delphine; Paquette, Linda

    2015-12-01

    Residential schools were the institutions, in operation from the 19th century to the late 20th century, which Indigenous children in Canada were forced to attend. The literature shows that many young people who attended these institutions were victims of neglect and abuse. Negative psychological effects resulting from child abuse have been amply documented. However, very few studies on this subject have been carried out among Canada's Indigenous Peoples. The objective of this study is to evaluate, for an Indigenous population in Quebec (Canada), the impact of residential schooling as well as self-reported experiences of sexual and physical abuse during childhood on the development of alcohol and drug use problems in adulthood. A total of 358 Indigenous participants were interviewed (164 men [45.8%] and 194 women [54.2%]). Alcoholism was evaluated using the Michigan Alcoholism Screening Test (MAST). Drug abuse was assessed with the Drug Abuse Screening Test-20 (DAST). Child abuse and residential schooling were assessed with dichotomous questions (yes/no). Among the participants, 28.5% (n=102) had attended residential schools, 35.2% (n=121) reported having experienced sexual abuse, and 34.1% (n=117) reported having experienced physical abuse before adulthood. Results of the exact logistic regression analyses indicated that residential school attendance was linked to alcohol problems, while child abuse was related to drug use problems. The results of this study highlight the importance of considering the consequences of historical traumas related to residential schools to better understand the current situation of Indigenous Peoples in Canada. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Life cycle primary energy analysis of residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, Leif; Joelsson, Anna [Ecotechnology, Department of Engineering and Sustainable Development, Mid Sweden University, SE-831 25 Oestersund (Sweden)

    2010-02-15

    The space heating demand of residential buildings can be decreased by improved insulation, reduced air leakage and by heat recovery from ventilation air. However, these measures result in an increased use of materials. As the energy for building operation decreases, the relative importance of the energy used in the production phase increases and influences optimization aimed at minimizing the life cycle energy use. The life cycle primary energy use of buildings also depends on the energy supply systems. In this work we analyse primary energy use and CO{sub 2} emission for the production and operation of conventional and low-energy residential buildings. Different types of energy supply systems are included in the analysis. We show that for a conventional and a low-energy building the primary energy use for production can be up to 45% and 60%, respectively, of the total, depending on the energy supply system, and with larger variations for conventional buildings. The primary energy used and the CO{sub 2} emission resulting from production are lower for wood-framed constructions than for concrete-framed constructions. The primary energy use and the CO{sub 2} emission depend strongly on the energy supply, for both conventional and low-energy buildings. For example, a single-family house from the 1970s heated with biomass-based district heating with cogeneration has 70% lower operational primary energy use than if heated with fuel-based electricity. The specific primary energy use with district heating was 40% lower than that of an electrically heated passive row house. (author)

  3. An investigation of hydrogen storage methods for fuel cell operation with man-portable equipment

    Energy Technology Data Exchange (ETDEWEB)

    Browning, D [Defence Evaluation and Research Agency, Haslar (United Kingdom); Jones, P [Defence Evaluation and Research Agency, Haslar (United Kingdom); Packer, K [Defence Evaluation and Research Agency, Haslar (United Kingdom)

    1997-03-01

    Air breathing proton exchange membrane fuel cells (PEMFC) are being considered as a power source for man-portable equipment, such as army radios. In addition to the weight and volume of the fuel cell itself, the device producing hydrogen with which to fuel the cell is also of crucial importance. This paper describes a number of hydrogen storage methods and discusses their applicability to man-portable equipment. (orig.)

  4. Radon exposure system for mammalian cells in culture: Design, operation, and dosimetry

    International Nuclear Information System (INIS)

    Seed, T.M.; Kretz, N.D.; Schlenker, R.A.

    1991-01-01

    A novel system for Rn gas exposure of mammalian cells in culture has been designed, constructed, and used to directly assess both the magnitude and the nature of chronic, low-dose Rn/Rn daughter toxicity of exposed vital lung cells isolated from normal pulmonary tissue, propagated and exposed in vitro. Direct correlations between atmospheric Rn concentrations, alpha-particle fluences, and macro- and microdoses of absorbed radiation doses by lung cells provide for a heretofore unavailable assessment of critical doses to vital cells

  5. Comparison of microbial electrolysis cells operated with added voltage or by setting the anode potential

    KAUST Repository

    Nam, Joo-Youn; Tokash, Justin C.; Logan, Bruce E.

    2011-01-01

    = 0.6 V. Gas production was 1.4 times higher with EAn = -0.2 V than with Eap = 0.6 V. Methane production was also reduced at set anode potentials of -0.2 V and higher than the other operating conditions. Continuous flow operation of the MECs

  6. The structural and functional differentiation of hair cells in a lizard's basilar papilla suggests an operational principle of amniote cochleas.

    Science.gov (United States)

    Chiappe, M Eugenia; Kozlov, Andrei S; Hudspeth, A J

    2007-10-31

    The hair cells in the mammalian cochlea are of two distinct types. Inner hair cells are responsible for transducing mechanical stimuli into electrical responses, which they forward to the brain through a copious afferent innervation. Outer hair cells, which are thought to mediate the active process that sensitizes and tunes the cochlea, possess a negligible afferent innervation. For every inner hair cell, there are approximately three outer hair cells, so only one-quarter of the hair cells directly deliver information to the CNS. Although this is a surprising feature for a sensory system, the occurrence of a similar innervation pattern in birds and crocodilians suggests that the arrangement has an adaptive value. Using a lizard with highly developed hearing, the tokay gecko, we demonstrate in the present study that the same principle operates in a third major group of terrestrial animals. We propose that the differentiation of hair cells into signaling and amplifying classes reflects incompatible strategies for the optimization of mechanoelectrical transduction and of an active process based on active hair-bundle motility.

  7. Isolated Full Bridge Boost DC-DC Converter Designed for Bidirectional Operation of Fuel Cells/Electrolyzer Cells in Grid-Tie Applications

    DEFF Research Database (Denmark)

    Pittini, Riccardo; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    Energy production from renewable energy sources is continuously varying, for this reason energy storage is becoming more and more important as the percentage of green energy increases. Newly developed fuel cells can operate in reverse mode as electrolyzer cells; therefore, they are becoming...... current. Dc-dc converter efficiency plays a fundamental role in the overall system efficiency since processed energy is always flowing through the converter; for this reason, loss analysis and optimization are a key component of the converter design. The paper presents an isolated full bridge boost dc...

  8. Evaluation of residential furnace filters

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, D. [Bowser Technical Inc. (Canada)

    1999-07-01

    Various filters rotated through six houses in southern Ontario during the heating season were evaluated for their filtration efficiency, including their ability to trap respirable particulate matter. Particulate levels were continuously monitored in the outside air, before and after the filter in the ducting system; also in the air in two rooms in each house. Results show that the filters performed according to their respective efficiency ratings. The integrated breathing zone exposure reading were not considered as significant as the reductions in the ducting system, dur to the fact that the integrated breathing zone exposure reflects both dust generation and dust removal mechanisms. Electronic air filters were found to produce ozone inside the home when the air-handling system was in operation. There was no evidence of any particular relationship between cleanliness and ozone production. Indoor ozone levels were always lower than outdoor levels. Continuous blower operation was found to improve filtration efficiency , however, it could result in an increase of about $250 in annual energy expenses. Bypass filters recorded significantly higher electrical energy consumption than full-flow systems. Continuous low-speed air handler fan operation appeared to be the most effective strategy. Portable air cleaners were shown to be highly effective in removing particulates in a single room. Removing footwear on entering the house, keeping major dust generators out of the house, frequent vacuuming, improving the air tightness of the house, and installing an air intake filter on the air supply may all be all be helpful in controlling exposure to particulates. 21 refs., 8 tabs., 32 figs.

  9. Validation of cell voltage and water content in a PEM (polymer electrolyte membrane) fuel cell model using neutron imaging for different operating conditions

    International Nuclear Information System (INIS)

    Salva, J. Antonio; Iranzo, Alfredo; Rosa, Felipe; Tapia, Elvira

    2016-01-01

    This work presents a one dimensional analytical model developed for a 50 cm"2 PEM (polymer electrolyte membrane) fuel cell with five-channel serpentine flow field. The different coupled physical phenomena such as electrochemistry, mass transfer of hydrogen, oxygen and water (two phases) together with heat transfer have been solved simultaneously. The innovation of this work is that the model has been validated with two different variables simultaneously and quantitatively in order to ensure the accuracy of the results. The selected variables are the cell voltage and the water content within the membrane MEA (Membrane Electrode Assembly) and GDL (gas diffusion layers) experimentally measured by means of neutron radiography. The results show a good agreement for a comprehensive set of different operating conditions of cell temperature, pressure, reactants relative humidity and cathode stoichiometry. The analytical model has a relative error less than 3.5% for the value of the cell voltage and the water content within the GDL + MEA for all experiments performed. This result presents a new standard of validation in the state of art of PEM fuel cell modeling where two variables are simultaneously and quantitatively validated with experimental results. The developed analytical model has been used in order to analyze the behavior of the PEM fuel cell under different values of relative humidity. - Highlights: • One dimensional analytical model has been developed for a PEM fuel cell. • The model is validated with two different variables simultaneously. • New standard of validation is proposed.

  10. Approaches and Recent Development of Polymer Electrolyte Membranes For Fuel Cells Operational Above 100°C

    DEFF Research Database (Denmark)

    Li, Qingfeng; He, Ronghuan; Jensen, Jens Oluf

    2003-01-01

    The state-of-the-art of polymer electrolyte membrane fuel cell (PEMFC) technology is based on perfluorosulfonic acid (PFSA) polymer membranes operating at a typical temperature of 80 °C. Some of the key issues and shortcomings of the PFSA-based PEMFC technology are briefly discussed. These include...... water management, CO poisoning, hydrogen, reformate and methanol as fuels, cooling, and heat recovery. As a means to solve these shortcomings, hightemperature polymer electrolyte membranes for operation above 100 °C are under active development. This treatise is devoted to a review of the area...... encompassing modified PFSA membranes, alternative sulfonated polymer and their composite membranes, and acidbase complex membranes. PFSA membranes have been modified by swelling with nonvolatile solvents and preparing composites with hydrophilic oxides and solid proton conductors. DMFC and H2/O2(air) cells...

  11. Effects of the operational conditions on the membrane and electrode properties of a polymer electrolyte fuel cell

    Directory of Open Access Journals (Sweden)

    Passos Raimundo R.

    2002-01-01

    Full Text Available The effects of the operational conditions on the membrane and electrode properties on a polymer electrolyte fuel cell (PEFC were investigated as a function of the cell and the gas humidifiers temperatures, the thickness of the membrane, the impregnation with phosphotungstic acid (PWA, and the variation of the Nafion and Teflon contents in the gas diffusion electrodes. An increase of the membrane resistance was observed when the PEFC is operated at temperatures equal or higher than those of the gas humidifiers, and this is more apparent for thicker electrolyte films. In the presence of PWA, the physicochemical properties of the membrane do not appreciably change with temperature. However, in this case, a lower humidification temperature affects the electrode performance. Changes on the Nafion loading in the electrodes do not lead to any significant effect in the electrode and membrane properties. For high Teflon contents there is a small lowering of the membrane conductivity.

  12. The myeloma stem cell concept, revisited: From phenomenology to operational terms

    NARCIS (Netherlands)

    H.E. Johnsen (Hans); M. Bøgsted (Martin); A. Schmitz; Bødker, J.S. (Julie Støve); El-Galaly, T.C. (Tarec Christoffer); Johansen, P. (Preben); P. Valent (Peter); Zojer, N. (Niklas); E. van Valckenborgh (Els); Vanderkerken, K. (Karin); M. van Duin (Mark); P. Sonneveld (Pieter); M. Perez-Andres; A. Orfao (Alberto); K. Dybkær (Karen)

    2016-01-01

    textabstractThe concept of the myeloma stem cell may have important therapeutic implications, yet its demonstration has been hampered by a lack of consistency in terms and definitions. Here, we summarize the current documentation and propose single-cell in vitro studies for future translational

  13. Operation of real landfill gas fueled solid oxide fuel cell (SOFC) using internal dry reforming

    DEFF Research Database (Denmark)

    Langnickel, Hendrik; Hagen, Anke

    2017-01-01

    Biomass is one renewable energy source, which is independent from solar radiation and wind effect. Solid oxide fuel cells (SOFC’s) are able to convert landfill gas derived from landfill directly into electricity and heat with a high efficiency. In the present work a planar 16cm2 SOFC cell...... was necessary to prevent poisoning and thereby to decrease the degradation rate....

  14. Charge yield potential of indoor-operated solar cells incorporated into Product Integrated Photovoltaic (PIPV)

    NARCIS (Netherlands)

    Reich, N.H.; van Sark, W.G.J.H.M.; Turkenburg, W.C.

    2010-01-01

    Solar cell performance parameters (open circuit voltage, short circuit current, fill factor and efficiency) are derived for different solar cell types for the irradiance range 0.1–1000 W/m2. Also it is demonstrated how spectral mismatch factors for indoor lighting conditions are calculated. The

  15. Effect of combustion condition on cytotoxic and inflammatory activity of residential wood combustion particles

    Science.gov (United States)

    Jalava, Pasi I.; Salonen, Raimo O.; Nuutinen, Kati; Pennanen, Arto S.; Happo, Mikko S.; Tissari, Jarkko; Frey, Anna; Hillamo, Risto; Jokiniemi, Jorma; Hirvonen, Maija-Riitta

    2010-05-01

    Residential heating is an important local source of fine particles and may cause significant exposure and health effects in populations. We investigated the cytotoxic and inflammatory activity of particulate emissions from normal (NC) and smouldering (SC) combustion in one masonry heater. The PM 1-0.2 and PM 0.2 samples were collected from the dilution tunnel with a high-volume cascade impactor (HVCI). Mouse RAW 264.7 macrophages were exposed to the PM-samples for 24 h. Inflammatory mediators, (IL-6, TNFα and MIP-2), and cytotoxicity (MTT-test), were measured. Furthermore, apoptosis and cell cycle of macrophages were analyzed. The HVCI particulate samples were characterized for ions, elements and PAH compounds. Assays of elemental and organic carbon were conducted from parallel low volume samples. All the samples displayed mostly dose-dependent inflammatory and cytotoxic activity. SC samples were more potent than NC samples at inducing cytotoxicity and MIP-2 production, while the order of potency was reversed in TNFα production. SC-PM 1-0.2 sample was a significantly more potent inducer of apoptosis than the respective NC sample. After adjustment for the relative toxicity with emission factor (mg MJ -1), the SC-PM emissions had clearly higher inflammatory and cytotoxic potential than the NC-PM emissions. Thus, operational practice in batch burning of wood and the resultant combustion condition clearly affect the toxic potential of particulate emissions.

  16. Effect of fabrication and operating parameters on electrochemical property of anode and cathode for direct methanol fuel cells

    International Nuclear Information System (INIS)

    Liu, Guicheng; Zhou, Hongwei; Ding, Xianan; Li, Xinping; Zou, Dechun; Li, Xinyang; Wang, Xindong; Lee, Joong Kee

    2016-01-01

    Highlights: • A quick and simple method for optimizing assembly force of fuel cells. • Effect mechanisms of operating parameters on polarization of each electrode. • Working temperature is main factor to affect the optimal flow rates. • This paper is helpful to simulate the relation between operating parameters. - Abstract: A quick and simple method for optimizing assembly force of the direct methanol fuel cell has been introduced. Meanwhile, the effect mechanism of operating parameters on fuel cell performance and the properties of single anode and cathode have been intuitively investigated by a three-electrode system in this paper. The impedance curves indicate that internal resistance is the suitable intermediate to connect assembly torque and assembly force. The cathode polarization curve and limiting current density of methanol crossover are shown that the increasing methanol concentration markedly exacerbates the polarization in cathode due to serious methanol crossover phenomenon. Also, the higher cathode backpressure mainly improves cathode property, and lowers methanol crossover simultaneously. Finally, the summaries of peak power densities prove that the main factor that affected the optimal flow rates of methanol and oxygen is not the concentration or backpressure, but the working temperature.

  17. Development of materials for use in solid oxid fuel cells anodes using renewable fuels in direct operation

    International Nuclear Information System (INIS)

    Lima, D.B.P.L. de; Florio, D.Z. de; Bezerra, M.E.O.

    2016-01-01

    Fuel cells produce electrical current from the electrochemical combustion of a gas or liquid (H2, CH4, C2H5OH, CH3OH, etc.) inserted into the anode cell. An important class of fuel cells is the SOFC (Solid Oxide Cell Fuel). It has a ceramic electrolyte that transports protons (H +) or O-2 ions and operating at high temperatures (500-1000 °C) and mixed conductive electrodes (ionic and electronic) ceramics or cermets. This work aims to develop anodes for fuel cells of solid oxide (SOFC) in order to direct operations with renewable fuels and strategic for the country (such as bioethanol and biogas). In this context, it becomes important to study in relation to the ceramic materials, especially those that must be used in high temperatures. Some types of double perovskites such as Sr2MgMoO6 (or simply SMMO) have been used as anodes in SOFC. In this study were synthesized by the polymeric precursor method, analyzed and characterized different ceramic samples of families SMMO, doped with Nb, this is: Sr2 (MgMo)1-xNbxO6 with 0 ≤ x ≤ 0.2. The materials produced were characterized by various techniques such as, thermal analysis, X-ray diffraction and scanning electron microscopy, and electrical properties determined by dc and ac measurements in a wide range of temperature, frequency and partial pressure of oxygen. The results of this work will contribute to a better understanding of advanced ceramic properties with mixed driving (electronic and ionic) and contribute to the advancement of SOFC technology operating directly with renewable fuels. (author)

  18. Hierarchical Load Tracking Control of a Grid-connected Solid Oxide Fuel Cell for Maximum Electrical Efficiency Operation

    DEFF Research Database (Denmark)

    Li, Yonghui; Wu, Qiuwei; Zhu, Haiyu

    2015-01-01

    efficiency operation obtained at different active power output levels, a hierarchical load tracking control scheme for the grid-connected SOFC was proposed to realize the maximum electrical efficiency operation with the stack temperature bounded. The hierarchical control scheme consists of a fast active...... power control and a slower stack temperature control. The active power control was developed by using a decentralized control method. The efficiency of the proposed hierarchical control scheme was demonstrated by case studies using the benchmark SOFC dynamic model......Based on the benchmark solid oxide fuel cell (SOFC) dynamic model for power system studies and the analysis of the SOFC operating conditions, the nonlinear programming (NLP) optimization method was used to determine the maximum electrical efficiency of the grid-connected SOFC subject...

  19. Design, Operation, Control, and Economics of a Photovoltaic/Fuel Cell/Battery Hybrid Renewable Energy System for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Zachary S. Whiteman

    2015-06-01

    Full Text Available Meeting rapidly growing global energy demand—without producing greenhouse gases or further diminishing the availability of non-renewable resources—requires the development of affordable low-emission renewable energy systems. Here, we develop a hybrid renewable energy system (HRES for automotive applications—specifically, a roof-installed photovoltaic (PV array combined with a PEM fuel cell/NiCd battery bus currently operating shuttle routes on the University of Delaware campus. The system’s overall operating objectives—meeting the total power demand of the bus and maintaining the desired state of charge (SOC of the NiCd battery—are achieved with appropriately designed controllers: a logic-based “algebraic controller” and a standard PI controller. The design, implementation, and performance of the hybrid system are demonstrated via simulation of real shuttle runs under various operating conditions. The results show that both control strategies perform equally well in enabling the HRES to meet its objectives under typical operating conditions, and under sudden cloud cover conditions; however, at consistently high bus speeds, battery SOC maintenance is better, and the system consumes less hydrogen, with PI control. An economic analysis of the PV investment necessary to realize the HRES design objectives indicates a return on investment of approximately 30% (a slight, but nonetheless positive, ~$550 profit over the bus lifetime in Newark, DE, establishing the economic viability of the proposed addition of a PV array to the existing University of Delaware fuel cell/battery bus.

  20. In situ fluorescence spectroscopy correlates ionomer degradation to reactive oxygen species generation in an operating fuel cell.

    Science.gov (United States)

    Prabhakaran, Venkateshkumar; Arges, Christopher G; Ramani, Vijay

    2013-11-21

    The rate of generation of reactive oxygen species (ROS) within the polymer electrolyte membrane (PEM) of an operating proton exchange member fuel cell (PEMFC) was monitored using in situ fluorescence spectroscopy. A modified barrier layer was introduced between the PEM and the electrocatalyst layer to eliminate metal-dye interactions and fluorescence resonance energy transfer (FRET) effects during measurements. Standard fuel cell operating parameters (temperature, relative humidity, and electrode potential) were systematically varied to evaluate their influence on the rate of ROS generation during PEMFC operation. Independently, the macroscopic rate of PEM degradation was measured by monitoring the fluoride ion emission rate (FER) in the effluent stream at each operating condition. The ROS generation reaction rate constant (estimated from the in situ fluorescence experiments) correlated perfectly with the measured FER across all conditions, demonstrating unequivocally for the first time that a direct correlation exists between in situ ROS generation and PEM macroscopic degradation. The activation energy for ROS generation within the PEM was estimated to be 12.5 kJ mol(-1).

  1. Unraveling micro- and nanoscale degradation processes during operation of high-temperature polymer-electrolyte-membrane fuel cells

    Science.gov (United States)

    Hengge, K.; Heinzl, C.; Perchthaler, M.; Varley, D.; Lochner, T.; Scheu, C.

    2017-10-01

    The work in hand presents an electron microscopy based in-depth study of micro- and nanoscale degradation processes that take place during the operation of high-temperature polymer-electrolyte-membrane fuel cells (HT-PEMFCs). Carbon supported Pt particles were used as cathodic catalyst material and the bimetallic, carbon supported Pt/Ru system was applied as anode. As membrane, cross-linked polybenzimidazole was used. Scanning electron microscopy analysis of cross-sections of as-prepared and long-term operated membrane-electrode-assemblies revealed insight into micrometer scale degradation processes: operation-caused catalyst redistribution and thinning of the membrane and electrodes. Transmission electron microscopy investigations were performed to unravel the nanometer scale phenomena: a band of Pt and Pt/Ru nanoparticles was detected in the membrane adjacent to the cathode catalyst layer. Quantification of the elemental composition of several individual nanoparticles and the overall band area revealed that they stem from both anode and cathode catalyst layers. The results presented do not demonstrate any catastrophic failure but rather intermediate states during fuel cell operation and indications to proceed with targeted HT-PEMFC optimization.

  2. Free tissue transfer in patients with sickle cell disease: Considerations for multi-disciplinary peri-operative management.

    Science.gov (United States)

    Cooper, Lilli; Seth, Rohit; Rhodes, Elizabeth; Alousi, Mohammed; Sivakumar, Bran

    2017-01-01

    Sickle cell disease (SCD) is an increasingly common condition in the UK. The safety of free tissue transfer in these patients is controversial, and no specific guidelines exist. The aim of this paper is to create recommendations for the plastic surgical multidisciplinary team for use in the assessment and management of SCD patients undergoing free tissue transfer and reconstruction. A literature review was performed in PubMed of 'sickle [TiAb] AND plast* adj3 surg*. Sickle cell disease is explained, as is the relative peri-operative risk in different genotypes of SCD. Acute and chronic manifestations of SCD are described by system, for consideration at pre-operative assessment and post-operative review. The evidence surrounding free tissue transfer and SCD is discussed and the outcomes in published cases summarised. An algorithm for peri-operative multi-disciplinary management is outlined and justified. Free tissue transfer theoretically carries a high risk of a crisis, due not only to long anaesthetic times, but the potential requirement for tourniquet use, and the relatively hypoxic state of the transferred tissue. This paper outlines a useful, practical algorithm to optimise the safety of free tissue transfer in patients with SCD. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Lifting and protecting residential structures from subsidence damage using airbags

    International Nuclear Information System (INIS)

    Triplett, T.L.; Bennett, R.M.

    1998-01-01

    Conventional practice in protecting residential structures from subsidence damage concentrates on saving the superstructure. The foundation is sacrificed, even though it represents the structural component with the greatest replacement cost. In this study, airbags were used to lift a 20 ft x 30 ft structure to test their ability to protect both the foundation and superstructure from ground settlement. Two contiguous sides of the test foundation were unreinforced, and the other two contiguous sides incorporated footing and wall reinforcement. The airbags successfully lifted the structure without causing damage, even on the unreinforced sides. This paper gives a procedure for determining airbag spacing, and describes installation and operation techniques of the airbags. The paper then focuses on the performance of the airbags in lifting the structure, and shows that airbags can preserve existing foundations during subsidence movements

  4. Charging Schedule for Electric Vehicles in Danish Residential Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2015-01-01

    energy sources like wind in power systems. The EV batteries could be used to charge during periods of excess electricity production from wind power and reduce the charging rate or discharge on deficit of power in the grid, supporting system stability and reliability. By providing such grid services......The prospects of Electric Vehicles (EVs) in providing clean transportation and supporting renewable electricity is widely discussed in sustainable energy forums worldwide. The battery storage of EVs could be used to address the variability and unpredictability of electricity produced from renewable......, the vehicle owner, vehicle fleet operator and other parties involved in the process could economically benefit from the process. This paper investigates an optimal EV charging plan in Danish residential distribution grids in view of supporting high volumes of wind power in electricity grids. The results...

  5. Computer program for sizing residential energy recovery ventilator

    International Nuclear Information System (INIS)

    Koontz, M.D.; Lee, S.M.; Spears, J.W.; Kesselring, J.P.

    1991-01-01

    Energy recovery ventilators offer the prospect of tighter control over residential ventilation rates than manual methods, such as opening windows, with a lesser energy penalty. However, the appropriate size of such a ventilator is not readily apparent in most situations. Sizing of energy recovery ventilation software was developed to calculate the size of ventilator necessary to satisfy ASHRAE Standard 62-1989, Ventilation for Acceptable Air Quality, or a user-specified air exchange rate. Inputs to the software include house location, structural characteristics, house operations and energy costs, ventilation characteristics, and HVAC system COP/efficiency. Based on these inputs, the program estimates the existing air exchange rate for the house, the ventilation rate required to meet the ASHRAE standard or user-specified air exchange rate, the size of the ventilator needed to meet the requirement, and the expected changes in indoor air quality and energy consumption. In this paper an illustrative application of the software is provided

  6. Development of a solar powered residential air conditioner (General optimization)

    Science.gov (United States)

    Lowen, D. J.

    1976-01-01

    A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

  7. Solar photovoltaic/thermal residential experiment. Phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Darkazalli, G.

    1980-07-01

    Month-by-month energy transfer data between an occupied residence and its energy supply systems are presented. The data were obtained during the first phase of photovoltaic/thermal residential research conducted at the University of Texas at Arlington/Solar Energy Research Facility. This research was part of the US Department of Energy Photovoltaic/Thermal Project managed by the M.I.T. Lincoln Laboratory. Energy transfer data are divided into different categories depending on how the energy is consumed. Energy transfers between some system components are also categorized. These components include a flat-plate thermal collector array, a flat-plate photovoltaic array, a dc-to-ac inverter, thermal storage tanks, and a series heat pump. System operations included directing surplus electrical energy (generated by the photovoltaic array) into the local utility grid. The heat pump used off-peak utility power to chill water during the cooling season.

  8. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... of supply and extract air terminals and different winter and summer boundary conditions. Vertical air temperature, operative temperature and air velocity profiles were measured in different positions in the room, and equivalent temperatures were derived, in order to characterize thermal comfort. Contaminant...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  9. Synchrotron x-ray diffraction studies of the structural properties of electrode materials in operating battery cells

    International Nuclear Information System (INIS)

    Thurston, T.R.; Jisrawi, N.M.; Mukerjee, S.; Yang, X.Q.; McBreen, J.; Daroux, M.L.; Xing, X.K.

    1996-01-01

    Hard x rays from a synchrotron source were utilized in diffraction experiments which probed the bulk of electrode materials while they were operating in situ in battery cells. Two technologically relevant electrode materials were examined; an AB 2 -type anode in a nickel endash metal endash hydride cell and a LiMn 2 O 4 cathode in a Li-ion open-quote open-quote rocking chair close-quote close-quote cell. Structural features such as lattice expansions and contractions, phase transitions, and the formation of multiple phases were easily observed as either hydrogen or lithium was electrochemically intercalated in and out of the electrode materials. The relevance of this technique for future studies of battery electrode materials is discussed. copyright 1996 American Institute of Physics

  10. Cells for the examination of irradiated plutonium fuel elements - two years operation - may 1961/may 1963 (1963)

    International Nuclear Information System (INIS)

    Valentin, A.

    1963-01-01

    Within the framework of the 'Rapsodie' fast reactor program, prototype plutonium fuel elements are irradiated and then examined in an α β γ laboratory at Saclay. This laboratory consists of five in line cells and a lead enclosure microscope. Each cell contains an α sealed removable box 4 ft 3 in. high, 4 ft 11 in. wide and 5 ft 1 in. deep, fitted with one or two magnetic transmission indirect manipulators. The boxes are contained in an β γ shielded enclosure whose front face is constructed of cast iron panels 21-2/3 in. thick. Nitrogen circulating in a closed loop forms the atmosphere of the boxes. This laboratory is essentially intended for metallurgical research. The functions of the various cells are as follows: transferring and packing, cutting, density measurement and cathodic etching, storage and metallography. Work on radioactive materials began in April 1961. Operational incidents have always been of a material nature only. (author) [fr

  11. The electrolyte challenge for a direct methanol-air polymer electrolyte fuel cell operating at temperatures up to 200 C

    Science.gov (United States)

    Savinell, Robert; Yeager, Ernest; Tryk, Donald; Landau, Uziel; Wainright, Jesse; Gervasio, Dominic; Cahan, Boris; Litt, Morton; Rogers, Charles; Scherson, Daniel

    1993-01-01

    Novel polymer electrolytes are being evaluated for use in a direct methanol-air fuel cell operating at temperatures in excess of 100 C. The evaluation includes tests of thermal stability, ionic conductivity, and vapor transport characteristics. The preliminary results obtained to date indicate that a high temperature polymer electrolyte fuel cell is feasible. For example, Nafion 117 when equilibrated with phosphoric acid has a conductivity of at least 0.4 Omega(exp -1)cm(exp -1) at temperatures up to 200 C in the presence of 400 torr of water vapor and methanol vapor cross over equivalent to 1 mA/cm(exp 2) under a one atmosphere methanol pressure differential at 135 C. Novel polymers are also showing similar encouraging results. The flexibility to modify and optimize the properties by custom synthesis of these novel polymers presents an exciting opportunity to develop an efficient and compact methanol fuel cell.

  12. Panethnicity, Ethnic Diversity and Residential Segregation

    Science.gov (United States)

    Kim, Ann H.; White, Michael J.

    2013-01-01

    We consider the theoretical and empirical implications of the structural basis of panethnicity and of the layering of ethnic boundaries in residential patterns while simultaneously evaluating the ‘panethnic hypothesis’, that is, the extent to which homogeneity within panethnic categories can be assumed. Our results do show a panethnic effect – greater residential proximity is evident within panethnic boundaries than between, net of ethnic group size and metropolitan area, but this association clearly depends on immigration. While findings generally show a lower degree of social distance between panethnic subgroups, particularly for blacks, whites and Latinos and less for Asians, ethno-national groups continue to maintain some degree of distinctiveness within a racialized context. PMID:20503650

  13. MICRO-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Gerstmann

    2009-01-31

    This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

  14. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  15. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  16. FACTOR ANALYSIS OF MULTISTOREY RESIDENTIAL BUILDINGS ZONE

    Directory of Open Access Journals (Sweden)

    Петр Матвеевич Мазуркин

    2016-02-01

    Full Text Available According to the UN classification of 11 classes of soil cover, the first three are grass, trees and shrubs and forests. In the city they correspond to the three elements of vegetation: lawns, tree plantings (trees and shrubs. We have adopted zoning for city-building to identify statistical regularities. Map dimensions in GIS "Map 2011" Yoshkar-Ola was allocated to "residential zone" and "Area of construction of multi-storey residential buildings (cadastral 58 quart crystals". The parameters of the elements of the vegetation cover have been considered: the number of elements of different levels, area and perimeter, the absolute and relative form, and activity of vegetation. As the result, we have obtained equations of binomial rank distributions, conducted the ratings and selected the best of cadastral quarter on environmental conditions.

  17. Electricity demand for South Korean residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Sa' ad, Suleiman [Surrey Energy Economics Centre (SEEC), Department of Economics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-12-15

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

  18. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  19. Adjustment problems and residential care environment

    Directory of Open Access Journals (Sweden)

    Jan Sebastian Novotný

    2015-01-01

    Full Text Available Problem: Residential care environment represents a specific social space that is associated with a number of negative consequences, covering most aspects of children and youth functioning. The paper analyzes of the presence of adjustment problems among adolescents from institutional care environment and compares this results with a population of adolescents who grew up in a family. Methods: The sample consisted of two groups of adolescents. The first group included 285 adolescents currently growing up in an residential care environment, aged 13 to 21 (M = 16.23, SD = 1.643. The second group consisted of 214 adolescents growing up in a family, aged 15 to 20 (M = 17.07, SD = 1.070. We used a questionnaire Youth Self Report. Data were analyzed using descriptive statistics and MANOVA. Results: Results showed that adolescents in residential care exhibit higher average values in all adjustment problems. Also, in the context of diagnostic categories are the residential care adolescents more frequently in non-normal range (borderline and clinical, primarily in the border range. The greatest differences were reflected in the Thought problems and Rule-breaking behavior. MANOVA showed a significant multivariate effect between groups of adolescents, Hotelling's T = .803, F(8, 490 = 49.202, p <.001, d = .445 (large effect. Univariate analysis further showed a significant effect for Withdrawn/depressed (p = .044, d = .089, small effect, Somatic complaints (p = .002, d = .139, medium effect, Social problems (p = 004, d = .127, a small effect, Thought problems (p <.001, d = .633, strong effect, Attention problems (p <.001, d = .320,strong effect, Rule-breaking behavior (p <.001 , d = .383, strong effect, and Aggressive behavior (p = 015, d = .110, small effect. Results for the dimension of Anxious/depressed were not significant (p = .159. Discussion: The results didn’t confirmed the assumption that more than 30% of residential care adolescents have adjustment

  20. Residential environmental evaluation of local cities considering regional characteristic and personal residential preference-a case study of Saga City,Japan

    Institute of Scientific and Technical Information of China (English)

    GE Jian; HOKAO Kazunori

    2004-01-01

    Questionnaire surveys and subjective evaluations on residential environment were performed in order to grasp the main factors of residential environment of small local cities. The suitable evaluation index system was established, and the regional residential environment characteristics and personal residential preference types were analyzed, so that their influence on residential environment evaluation could be grasped. The results can be applied to the residential environment planning, construction and monitoring of local cities.

  1. The role of hydrogen as a future solution to energetic and environmental problems for residential buildings

    Science.gov (United States)

    Badea, G.; Felseghi, R. A.; Aşchilean, I.; Rǎboacǎ, S. M.; Şoimoşan, T.

    2017-12-01

    The concept of sustainable development aims to meet the needs of the present without compromising the needs of future generations. In achieving the desideratum "low-carbon energy system", in the domain of energy production, the use of innovative low-carbon technologies providing maximum efficiency and minimum pollution is required. Such technology is the fuel cell; as these will be developed, it will become a reality to obtain the energy based on hydrogen. Thus, hydrogen produced by electrolysis of water using different forms of renewable resources becomes a secure and sustainable energy alternative. In this context, in the present paper, a comparative study of two different hybrid power generation systems for residential building placed in Cluj-Napoca was made. In these energy systems have been integrated renewable energies (photovoltaic panels and wind turbine), backup and storage system based on hydrogen (fuel cell, electrolyser and hydrogen storage tank), and, respectively, backup and storage system based on traditional technologies (diesel generator and battery). The software iHOGA was used to simulate the operating performance of the two hybrid systems. The aim of this study was to compare energy, environmental and economic performances of these two systems and to define possible future scenarios of competitiveness between traditional and new innovative technologies. After analyzing and comparing the results of simulations, it can be concluded that the fuel cells technology along with hydrogen, integrated in a hybrid system, may be the key to energy production systems with high energy efficiency, making possible an increased capitalization of renewable energy which have a low environmental impact.

  2. Evaluation of the energy efficiency of active pass through wall cooling surface with phase change material in residential buildings combined with cistern cooling and operation optimization by development of suitable control strategies; Evaluierung der Energieeffizienz von aktiv durchstroemten Wandkuehlflaechen mit Phasenwechselmaterial in Wohngebaeuden in Kombination mit einer Zisternenkuehlung und Optimierung des Betriebes durch Entwicklung geeigneter Regelstrategien

    Energy Technology Data Exchange (ETDEWEB)

    Stoelzel, Christof [Variotec, Neumarkt (Germany); Kalz, Doreen; Wienold, Jan; Fischer, Martin [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany). Gruppe Solares Bauen

    2009-07-01

    This work introduces and evaluates a novel heating and cooling concept employing thermo-active building systems and environmental energy harnessed from 22-m{sup 3} rainwater cisterns for a 290-m{sup 2} low energy residential building in Germany. The building strives for a significantly reduced primary energy use with carefully coordinated measures such as high quality building envelope by means of vacuum insulated panels, supply and exhaust air system with heat recovery, reduced solar heat gains (solar shading), and the integration of thermal solar collectors and photovoltaic in the plant system. On this premise, a comprehensive long-term monitoring over the course of two years in high time resolution was carried out with an accompanying commissioning of the building performance. Measurements comprise the energy use for heating, cooling, and ventilation, as well as the auxiliary equipment, the performance of the environmental heat source/sink, thermal comfort, air quality, and local climatic site conditions. The analysis focuses on the performance and the efficiency of the rainwater cisterns as natural heat source and sink as well as the heat pump system. First, the paper discusses the performance of the thermo-active building systems, investigates the occupant thermal comfort, determines the efficiency of the heating/cooling system, and evaluates the total end and primary energy use of the building. Second, various operation and control strategies for the cooling plant are investigated by means of a validated building and plant model in the dynamic simulation environment TRNSYS. The optimization is carried out in terms of energy efficiency, occupant thermal comfort and the availability of the rainwater cisterns over the summer months. The central findings of the analysis of the energy and efficiency performance of the HVAC according to four defined balance boundaries are the following: Rainwater cistern as environmental source und sink: The energy balance of the

  3. Immune cells in Chernobyl recovery operation workers exposed over 500 mSv

    International Nuclear Information System (INIS)

    Bazyka, D.; Byelyaeva, N.; Chumak, A.; Golyarnik, N.; Maznichenko, O.; Kovalenko, Ju.

    2004-01-01

    Immune response parameters were studied in Chernobyl radiation emergency workers exposed to radiation over 500 mSv during 1986. Initial response stage to the radiation exposure was characterised by immunological deficiency with T-cell subsets changes. In the reconstitution period inhibition of immune function was associated with lymphocyte subset changes such as decreased CD3 + and CD4 + cell counts and increased number of somatic mutations in TCR-locus. Late period after the acute radiation exposure in Chernobyl radiation emergency workers is characterized by decreased CD8 + suppressor cell function that could lead to poor proliferation control. Subset analysis of CD34 + cells showed in ARS survivors counts significantly higher than in control especially for the most primitive progenitors with CD34 + CD90 + CD45 -/l ow and CD34 + CD45 - CD38 - phenotypes. (author)

  4. A small mono-polar direct methanol fuel cell stack with passive operation

    Science.gov (United States)

    Chan, Y. H.; Zhao, T. S.; Chen, R.; Xu, C.

    A passive direct methanol fuel cell (DMFC) stack that consists of six unit cells was designed, fabricated, and tested. The stack was tested with different methanol concentrations under ambient conditions. It was found that the stack performance increased when the methanol concentration inside the fuel tank was increased from 2.0 to 6.0 M. The improved performance is primarily due to the increased cell temperature as a result of the exothermic reaction between the permeated methanol and oxygen on the cathode. Moreover, the increased cell temperature enhanced the water evaporation rate on the air-breathing cathode, which significantly reduced water flooding on the cathode and further improved the stack performance. This passive DMFC stack, providing 350 mW at 1.8 V, was successfully applied to power a seagull display kit. The seagull display kit can continuously run for about 4 h on a single charge of 25 cm 3 4.0-M methanol solution.

  5. Transition issues in an unbundled residential market

    International Nuclear Information System (INIS)

    Brett, J.D.

    1996-01-01

    Aspects of an unbundled residential gas market were discussed, among them (1) the role of a local distribution company (LDC), (2) the context and the issues, (3) the customers'needs and desires, (4) long term planning responsibility, (5) consumer protection and dealing with abuses, (6) the obligation to serve, (7) the bad credit risk customer, (8) billing, credit and collection, and (9) metering and CIS

  6. Adjustment problems and residential care environment

    OpenAIRE

    Jan Sebastian Novotný

    2015-01-01

    Problem: Residential care environment represents a specific social space that is associated with a number of negative consequences, covering most aspects of children and youth functioning. The paper analyzes of the presence of adjustment problems among adolescents from institutional care environment and compares this results with a population of adolescents who grew up in a family. Methods: The sample consisted of two groups of adolescents. The first group included 285 adolescents currently g...

  7. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  8. INVESTIGATION OF ELECTROMAGNETIC FIELDS IN RESIDENTIAL AREAS

    Directory of Open Access Journals (Sweden)

    Dušan MEDVEĎ

    2017-09-01

    Full Text Available This article is devoted to investigation of impact of electromagnetic fields around the electrical equipment used in a residential area and their impact on the human body. This paper was based on sets of measurements of magnetic induction B with magnetometer and on computational simulations in ANSYS for particular appliances often used in household. The results from measurements and simulations led to setting out the recommendations for practical action in the form of elimination of harmful electromagnetic radiation.

  9. Development Of Economic Techniques For Residential Thermography

    Science.gov (United States)

    Allen, Lee R.; Allen, Sharon

    1983-03-01

    Infrared thermography has proven to be a valuable tool in the detection of heat loss in both commercial and residential buildings. The field of residential thermography has needed a simple method with which to report the deficiencies found during an infrared scan. Two major obstacles hindering the cost effectiveness of residential thermography have been 1) the ability to quickly transport some high resolution imaging system equipment from job site to job site without having to totally dismount the instruments at each area, and 2) the lack of a standard form with which to report the findings of the survey to the customer. Since the industry has yet to provide us with either, we believed it necessary to develop our own. Through trial and error, we have come up with a system that makes interior residential thermography a profitable venture at a price the homeowner can afford. Insulation voids, or defects can be instantly spotted with the use of a thermal imaging system under the proper conditions. A special hand-held device was developed that enables the thermographer to carry the equipment from house to house without the need to dismantle and set up at each stop. All the necessary components are attached for a total weight of about 40 pounds. The findings are then conveyed to a form we have developed. The form is simple enough that the client without special training in thermography can understand. The client is then able to locate the problems and take corrective measures or give it to a con-tractor to do the work.

  10. Proton exchange membrane fuel cell operation and degradation in short-circuit.

    OpenAIRE

    Silva , R.E.; Harel , F.; Jemei , S.; Gouriveau , Rafael; Hissel , Daniel; Boulon , L.; Agbossou , K.

    2013-01-01

    International audience; Hybridization of proton exchange membrane fuel cells (PEMFC) and ultra capacitors (UC) are considered as an alternative way to implement high autonomy, high dynamic, and reversible energy sources. PEMFC allow high efficiency and high autonomy, however their dynamic response is limited and this source does not allow recovering energy. UC appears to be a complementary source to fuel cell systems (FCS) due to their high power density, fast dynamics, and reversibility. A d...

  11. Development of integrated system to operational control and monitoring for PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Mauricio Stelita; Ferreira, Valdemar Stelita [NovoCell Sistemas de Energia S.A., Santa Barbara D' Oeste, SP (Brazil)], Email: mauricio.ferreira@novocell.ind.br

    2010-07-01

    The demonstration of fuel cells prototype in some applications such as in stationary systems and vehicles has been increased, but higher costs and lack of criteria for system longevity still prevent their mass production. Acting directly on this aspect, Novocell has proposed to develop innovative processes and materials to manufacture at scale and with competitive cost for these systems. Thus, this paper presents solutions that enable its production line of PEM fuel cells. (author)

  12. Anode microbial communities produced by changing from microbial fuel cell to microbial electrolysis cell operation using two different wastewaters

    KAUST Repository

    Kiely, Patrick D.; Cusick, Roland; Call, Douglas F.; Selembo, Priscilla A.; Regan, John M.; Logan, Bruce E.

    2011-01-01

    Conditions in microbial fuel cells (MFCs) differ from those in microbial electrolysis cells (MECs) due to the intrusion of oxygen through the cathode and the release of H2 gas into solution. Based on 16S rRNA gene clone libraries, anode communities in reactors fed acetic acid decreased in species richness and diversity, and increased in numbers of Geobacter sulfurreducens, when reactors were shifted from MFCs to MECs. With a complex source of organic matter (potato wastewater), the proportion of Geobacteraceae remained constant when MFCs were converted into MECs, but the percentage of clones belonging to G. sulfurreducens decreased and the percentage of G. metallireducens clones increased. A dairy manure wastewater-fed MFC produced little power, and had more diverse microbial communities, but did not generate current in an MEC. These results show changes in Geobacter species in response to the MEC environment and that higher species diversity is not correlated with current. © 2010 Elsevier Ltd.

  13. Residential Treatment Centers for Child Abuse

    Directory of Open Access Journals (Sweden)

    Serhat Nasiroglu

    2014-02-01

    Full Text Available Every year millions of reports are being held and cases regarding those reports in courts are carrying on about abusement and omission against children . Abusement against children has been seen throughout of the history. Significant and permanent impacts can occur upon child abusement and neglect on victim children. It is important to know the psychological dynamics which have been lived by the children by the mental health professionalsto protect the children after the abusement report has been written. Cognitive Behaviour Therapy and medications are being used commonly in the treatment of abusement cases. However in some cases it is necessary to send away the victims from environment, enable them to continue their education life, make sure that they are treated by the professional individuals in safe area. For this end there are many Residential Treatment Centers around the world. and ldquo;Oguz Kagan Koksal Social Care and Rehabilitation Center and rdquo; was established in Adana as the first Residential Treatment Center in Turkey. In this report the historical dimensions of the child abusement, the definition of it, its psychological dynamics, the psychological disorders caused by it, treatment approaches and residential treatment centers have been reviewed. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2014; 6(1.000: 67-78

  14. Residential outage cost estimation: Hong Kong

    International Nuclear Information System (INIS)

    Woo, C.K.; Ho, T.; Shiu, A.; Cheng, Y.S.; Horowitz, I.; Wang, J.

    2014-01-01

    Hong Kong has almost perfect electricity reliability, the result of substantial investments ultimately financed by electricity consumers who may be willing to accept lower reliability in exchange for lower bills. But consumers with high outage costs are likely to reject the reliability reduction. Our ordered-logit regression analysis of the responses by 1876 households to a telephone survey conducted in June 2013 indicates that Hong Kong residents exhibit a statistically-significant preference for their existing service reliability and rate. Moreover, the average residential cost estimate for a 1-h outage is US$45 (HK$350), topping the estimates reported in 10 of the 11 studies published in the last 10 years. The policy implication is that absent additional compelling evidence, Hong Kong should not reduce its service reliability. - Highlights: • Use a contingent valuation survey to obtain residential preferences for reliability. • Use an ordered logit analysis to estimate Hong Kong's residential outage costs. • Find high outage cost estimates that imply high reliability requirements. • Conclude that sans new evidence, Hong Kong should not reduce its reliability

  15. Metal contamination in environmental media in residential ...

    Science.gov (United States)

    Hard-rock mining for metals, such as gold, silver, copper, zinc, iron and others, is recognized to have a significant impact on the environmental media, soil and water, in particular. Toxic contaminants released from mine waste to surface water and groundwater is the primary concern, but human exposure to soil contaminants either directly, via inhalation of airborne dust particles, or indirectly, via food chain (ingestion of animal products and/or vegetables grown in contaminated areas), is also, significant. In this research, we analyzed data collected in 2007, as part of a larger environmental study performed in the Rosia Montana area in Transylvania, to provide the Romanian governmental authorities with data on the levels of metal contamination in environmental media from this historical mining area. The data were also considered in policy decision to address mining-related environmental concerns in the area. We examined soil and water data collected from residential areas near the mining sites to determine relationships among metals analyzed in these different environmental media, using the correlation procedure in SAS statistical software. Results for residential soil and water analysis indicate that the average values for arsenic (As) (85 mg/kg), cadmium (Cd) (3.2 mg/kg), mercury (Hg) (2.3 mg/kg) and lead (Pb) (92 mg/kg) exceeded the Romanian regulatory exposure levels [the intervention thresholds for residential soil in case of As (25 mg/kg) and Hg

  16. Energy efficient residential house wall system

    International Nuclear Information System (INIS)

    Aldawi, Fayez; Date, Abhijit; Alam, Firoz; Khan, Iftekhar; Alghamdi, Mohammed

    2013-01-01

    The energy consumption and greenhouse gas emission by the residential housing sector are considered to be one of the largest in economically developed countries. The larger energy consumption and greenhouse gas emission not only put additional pressure on finite fossil fuel resources but also cause global warming and climate change. Additionally, the residential housing sector will be consuming more energy as the house demand and average house floor area are progressively increasing. With currently used residential house wall systems, it is hard to reduce energy consumption for ongoing house space heating and cooling. A smart house wall envelope with optimal thermal masses and insulation materials is vital for reducing our increasing energy consumption. The major aim of this study is to investigate thermal performance and energy saving potential of a new house wall system for variable climate conditions. The thermal performance modelling was carried out using commercially developed software AccuRate ® . The findings indicate that a notable energy savings can be accomplished if a smart house wall system is used. -- Highlights: • Smart house wall system. • Thermal performance modelling and star energy rating. • Energy savings and greenhouse gas reduction

  17. Research methods of the parameters of residential buildings construction

    Directory of Open Access Journals (Sweden)

    Grigor’ev Vladimir Aleksandrovich

    Full Text Available The analysis of construction theory and practice shows that rational organizational and technological parameters of the construction of residential buildings should be based on the manifestation in time and space of the most important stages construction with their harmonization. Basing on the experience of normalizing the construction duration, it is advisable to express the complex of residential buildings’ construction processes by their basic stages - preparatory period, underground part, aboveground part, external engineering networks and land improvement. The main indicators of the development and implementation of optimization solutions are: the total duration of the construction, the duration of the preparation period, the duration of the construction of the underground part, the duration of the construction of the aboveground part, the duration of external engineering networks laying, the duration of land improvement. The indicators of the total duration of the construction of residential buildings, the construction the underground and aboveground parts are determined on the basis of the operation of one assembly crane on an object of up to four sections. In case of more sections two (three cranes are considered and the total construction duration is set depending on these conditions. The duration of the construction of multisectional buildings is determined basing on the simultaneous construction of the stages or their combination with a certain time shift. However, this approach requires a significant amount of optimization solutions due to its multivariance. Therefore, in order to reduce the volume of calculations in some cases, for example, when planning the development of districts and neighborhoods, statistical methods can be used for determining the duration of the construction basing on the compilation of optimization solutions. The total duration of the construction and the duration of the main stages are multiple

  18. Experimental device for the residential heating with heat pipe and electric heat storage blocks

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Boldak, I M; Domorod, L S; Rabetsky, M I; Schirokov, E I [AN Belorusskoj SSR, Minsk (Belarus). Inst. Teplo- i Massoobmena

    1992-01-01

    Residential heating using electric heat storage blocks nowadays is an actual problem from the point of view of heat recovery and nature protection. In the Luikov Heat and Mass Transfer Institute a new residential electrical heater capable of heating chambers by controlling air temperature and heat output using heat pipes and an electric heat storage block was developed. This heater (BETA) is fed from the source of energy and during 7 h of night time accumulates energy sufficiently to heat 10 m{sup 3} during 24 h. Heating device BETA has a ceramic thermal storage block, electric heaters and a heat pipe with evaporator inside the ceramic block and constant temperature (65{sup o}C) finned condenser outside it. The condenser temperature could be controlled easily. BETA is compact, has high thermal response, accurate air temperature control and safe operation. Such types of residential heaters are necessary for heating residential and office building in the Mogilev and Gomel regions in Byelorussia which suffered after the Chernobyl catastrophe. (Author).

  19. Shelter planning based on self-saving concepts in urban residential districts

    Directory of Open Access Journals (Sweden)

    Buri Qi

    2017-01-01

    Full Text Available With increasing population density in Asia, the potential higher risk was resulted from the residential districts with the higher plot ratio, especially in some megapolis (eg. Beijing and Shanghai. Presently it is more difficult for the rescue operation during the disasters because of the decreasing safe space among the buildings as a result of higher buildings and denser the district. Thus, an immediate self-saving action is more important than before during the disaster in the residential districts, and its realization depends on the reasonable shelter planning and its management system. In this study, the factors related to the self-saving were analyzed and concluded by the related the literatures retrieval and case study, and the case study was done by the in-depth interview and questionnaires in three different residential districts in Shanghai. It was found that the following factors related to the self-saving should be considered in the shelters planning: the distribution of the shelters including their space accessibility and area, evacuation passageways, the facilities of the disaster prevention (such as fire hydrant and guide signs and subsidiary facilities (such as vegetation for the disaster prevention, the social cohesion, awareness of the self-saving and disaster prevention. Simultaneously, the shelters planning countermeasures based on the self-saving were proposed, which provided some theoretical bases for the study  and plan of the security residential districts in future.

  20. Up-regulation of Store-operated Ca2+ Entry and Nuclear Factor of Activated T Cells Promote the Acinar Phenotype of the Primary Human Salivary Gland Cells.

    Science.gov (United States)

    Jang, Shyh-Ing; Ong, Hwei Ling; Liu, Xibao; Alevizos, Ilias; Ambudkar, Indu S

    2016-04-15

    The signaling pathways involved in the generation and maintenance of exocrine gland acinar cells have not yet been established. Primary human salivary gland epithelial cells, derived from salivary gland biopsies, acquired an acinar-like phenotype when the [Ca(2+)] in the serum-free medium (keratinocyte growth medium, KGM) was increased from 0.05 mm (KGM-L) to 1.2 mm (KGM-H). Here we examined the mechanism underlying this Ca(2+)-dependent generation of the acinar cell phenotype. Compared with cells in KGM-L, those in KGM-H display enhancement of Orai1, STIM1, STIM2, and nuclear factor of activated T cells 1 (NFAT1) expression together with an increase in store-operated Ca(2+) entry (SOCE), SOCE-dependent nuclear translocation of pGFP-NFAT1, and NFAT-dependent but not NFκB-dependent gene expression. Importantly, AQP5, an acinar-specific protein critical for function, is up-regulated in KGM-H via SOCE/NFAT-dependent gene expression. We identified critical NFAT binding motifs in the AQP5 promoter that are involved in Ca(2+)-dependent up-regulation of AQP5. These important findings reveal that the Ca(2+)-induced switch of salivary epithelial cells to an acinar-like phenotype involves remodeling of SOCE and NFAT signaling, which together control the expression of proteins critically relevant for acinar cell function. Our data provide a novel strategy for generating and maintaining acinar cells in culture. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  1. Up-regulation of Store-operated Ca2+ Entry and Nuclear Factor of Activated T Cells Promote the Acinar Phenotype of the Primary Human Salivary Gland Cells*

    Science.gov (United States)

    Jang, Shyh-Ing; Ong, Hwei Ling; Liu, Xibao; Alevizos, Ilias; Ambudkar, Indu S.

    2016-01-01

    The signaling pathways involved in the generation and maintenance of exocrine gland acinar cells have not yet been established. Primary human salivary gland epithelial cells, derived from salivary gland biopsies, acquired an acinar-like phenotype when the [Ca2+] in the serum-free medium (keratinocyte growth medium, KGM) was increased from 0.05 mm (KGM-L) to 1.2 mm (KGM-H). Here we examined the mechanism underlying this Ca2+-dependent generation of the acinar cell phenotype. Compared with cells in KGM-L, those in KGM-H display enhancement of Orai1, STIM1, STIM2, and nuclear factor of activated T cells 1 (NFAT1) expression together with an increase in store-operated Ca2+ entry (SOCE), SOCE-dependent nuclear translocation of pGFP-NFAT1, and NFAT-dependent but not NFκB-dependent gene expression. Importantly, AQP5, an acinar-specific protein critical for function, is up-regulated in KGM-H via SOCE/NFAT-dependent gene expression. We identified critical NFAT binding motifs in the AQP5 promoter that are involved in Ca2+-dependent up-regulation of AQP5. These important findings reveal that the Ca2+-induced switch of salivary epithelial cells to an acinar-like phenotype involves remodeling of SOCE and NFAT signaling, which together control the expression of proteins critically relevant for acinar cell function. Our data provide a novel strategy for generating and maintaining acinar cells in culture. PMID:26903518

  2. Hierarchical Load Tracking Control of a Grid-Connected Solid Oxide Fuel Cell for Maximum Electrical Efficiency Operation

    Directory of Open Access Journals (Sweden)

    Yonghui Li

    2015-03-01

    Full Text Available Based on the benchmark solid oxide fuel cell (SOFC dynamic model for power system studies and the analysis of the SOFC operating conditions, the nonlinear programming (NLP optimization method was used to determine the maximum electrical efficiency of the grid-connected SOFC subject to the constraints of fuel utilization factor, stack temperature and output active power. The optimal operating conditions of the grid-connected SOFC were obtained by solving the NLP problem considering the power consumed by the air compressor. With the optimal operating conditions of the SOFC for the maximum efficiency operation obtained at different active power output levels, a hierarchical load tracking control scheme for the grid-connected SOFC was proposed to realize the maximum electrical efficiency operation with the stack temperature bounded. The hierarchical control scheme consists of a fast active power control and a slower stack temperature control. The active power control was developed by using a decentralized control method. The efficiency of the proposed hierarchical control scheme was demonstrated by case studies using the benchmark SOFC dynamic model.

  3. On the effect of operating conditions in liquid-feed direct methanol fuel cells: A multiphysics modeling approach

    International Nuclear Information System (INIS)

    García-Salaberri, Pablo A.; Vera, Marcos

    2016-01-01

    A multiphysics model for liquid-feed Direct Methanol Fuel Cells is presented. The model accounts for two-dimensional (2D) across-the-channel anisotropic mass and charge transport in the anode and cathode Gas Diffusion Layers (GDLs), including the effect of GDL assembly compression and electrical contact resistances at the Bipolar Plate (BPP) and membrane interfaces. A one-dimensional (1D) across-the-membrane model is used to describe local species diffusion through the microporous layers, methanol/water crossover, proton transport, and electrochemical reactions, thereby coupling both GDL sub-models. The 2D/1D model is extended to the third dimension and supplemented with 1D descriptions of the flow channels to yield a 3D/1D + 1D model that is successfully validated. A parametric study is then conducted on the 2D/1D model to examine the effect of operating conditions on cell performance. The results show that an optimum methanol concentration exists that maximizes power output due to the trade-off between anode polarization and cathode mixed overpotential. For fixed methanol concentration, cell performance is largely affected by the oxygen supply rate, cell temperature, and liquid/gas saturation levels. There is also an optimal GDL compression due to the trade-off between ohmic and concentration losses, which strongly depends on BPP material and, more weakly, on the actual operating conditions. - Highlights: • A multiphysics model for liquid-feed DMFCs is presented. • GDL anisotropic transport, assembly compression, and ohmic contact resistances are considered. • The model is successfully validated against previous experimental data. • Optimum methanol concentrations, GDL compressions, and operating temperatures are reported. • Oxygen-starved conditions with spontaneous hydrogen evolution in the anode are also considered.

  4. Residential Photovoltaic/Thermal Energy System

    Science.gov (United States)

    Selcuk, M. K.

    1987-01-01

    Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

  5. Electrochemical Impedance Spectroscopy (EIS) Characterization of Reformate-operated High Temperature PEM Fuel Cell Stack

    DEFF Research Database (Denmark)

    Sahlin, Simon Lennart; Simon Araya, Samuel; Andreasen, Søren Juhl

    2017-01-01

    their effects on a reformate-operated stack. Polarization curves were also recorded to complement the impedance analysis of the researched phenomena. An equivalent circuit model was used to estimate the different resistances at varying parameters. It showed a significantly higher low frequency resistance......, λanode= 1.6 for reformate operation and λcathode= 4.The work also compared dry hydrogen, steam reforming and autothermal reforming gas feeds at160 ◦Cand showed appreciably lower performance in the case of autothermal reforming at the same stoichiometry, mainly attributable to mass transport related...

  6. NEW POLYMER ELECTROLYTE MEMBRANES FOR FUEL CELLS OPERATING ABOVE 100°C

    DEFF Research Database (Denmark)

    Li, Qingfeng; Jensen, Jens Oluf; He, Ronghuan

    2003-01-01

    The state-of-the-art of PEMFC technology is based on perfluorosulfonic acid (PFSA) polymer membranes operating at a typical temperature of 80°C. The newest development in the field is alternative polymer electrolytes for operation above 100°C. This paper is devoted to a review on the development......, which is classified into three groups: modified PFSA membranes, alternative sulfonated polymer and their inorganic composite membranes and acid-base complex membranes. High temperature PEMFC has been demonstrated with advanced features such as fast electrode kinetics, high CO tolerance, simple thermal...

  7. Residential Radon Exposure and Incidence of Childhood Lymphoma in Texas, 1995–2011

    Directory of Open Access Journals (Sweden)

    Erin C. Peckham

    2015-09-01

    Full Text Available There is warranted interest in assessing the association between residential radon exposure and the risk of childhood cancer. We sought to evaluate the association between residential radon exposure and the incidence of childhood lymphoma in Texas. The Texas Cancer Registry (n = 2147 provided case information for the period 1995–2011. Denominator data were obtained from the United States Census. Regional arithmetic mean radon concentrations were obtained from the Texas Indoor Radon Survey and linked to residence at diagnosis. Exposure was assessed categorically: ≤25th percentile (reference, >25th to ≤50th percentile, >50th to ≤75th percentile, and >75th percentile. Negative binomial regression generated adjusted incidence rate ratios (aIRR and 95% confidence intervals (CI. We evaluated lymphoma overall and by subtype: Hodgkin (HL; n = 1248, Non-Hodgkin excluding Burkitt (non-BL NHL; n = 658, Burkitt (BL; n = 241, and Diffuse Large B-cell (DLBCL; n = 315. There was no evidence that residential radon exposure was positively associated with lymphoma overall, HL, or BL. Areas with radon concentrations >75th percentile had a marginal increase in DLBCL incidence (aIRR = 1.73, 95% CI: 1.03–2.91. In one of the largest studies of residential radon exposure and the incidence of childhood lymphoma, we found little evidence to suggest a positive or negative association; an observation consistent with previous studies.

  8. Improved reliability of residential heat pumps; Foerbaettrad driftsaekerhet hos villavaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Larsson, Kristin; Jensen, Sara; Larsson, Johan; Berg, Johan; Lidbom, Peter; Rolfsman, Lennart

    2012-07-01

    Today, heat pump heating systems are common in Swedish single-family houses. Many owners are pleased with their installation, but statistics show that a certain number of heat pumps break every year, resulting in high costs for both insurance companies and owners. On behalf of Laensfoersaekringars Forskningsfond, SP Energy Technology has studied the cause of the most common failures for residential heat pumps. The objective of the study was to suggest what measures to be taken to reduce the number of failures, i.e. improving the reliability of heat pumps. The methods used were analysis of public failure statistics and sales statistics and interviews with heat pump manufacturers, installers, service representatives and assessors at Laensfoersaekringar. In addition, heat pump manuals have been examined and literature searches for various methods for durability tests have been performed. Based on the outcome from the interviews the most common failures were categorized by if they; 1. Could have been prevented by better operation and maintenance of the heat pump. 2. Caused by a poorly performed installation. 3. Could have been prevented if certain parameters had been measured, recorded and followed up. 4. Are due to poor quality of components or systems. However, the results show that many of the common failures fall into several different categories and therefore, different types of measures must be taken to improve the operational reliability of residential heat pumps. The interviews tell that failures often are caused by poor installation, neglected maintenance and surveillance, and poor quality of standard components or that components are used outside their declared operating range. The quality of the installations could be improved by increasing installers' knowledge about heat pumps and by requiring that an installation protocol shall be filled-in. It is also important that the owner of the heat pump performs the preventive maintenance recommended by the

  9. Improved reliability of residential heat pumps; Foerbaettrad driftsaekerhet hos villavaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Larsson, Kristin; Jensen, Sara; Larsson, Johan; Berg, Johan; Lidbom, Peter; Rolfsman, Lennart

    2012-07-01

    Today, heat pump heating systems are common in Swedish single-family houses. Many owners are pleased with their installation, but statistics show that a certain number of heat pumps break every year, resulting in high costs for both insurance companies and owners. On behalf of Laensfoersaekringars Forskningsfond, SP Energy Technology has studied the cause of the most common failures for residential heat pumps. The objective of the study was to suggest what measures to be taken to reduce the number of failures, i.e. improving the reliability of heat pumps. The methods used were analysis of public failure statistics and sales statistics and interviews with heat pump manufacturers, installers, service representatives and assessors at Laensfoersaekringar. In addition, heat pump manuals have been examined and literature searches for various methods for durability tests have been performed. Based on the outcome from the interviews the most common failures were categorized by if they; 1. Could have been prevented by better operation and maintenance of the heat pump. 2. Caused by a poorly performed installation. 3. Could have been prevented if certain parameters had been measured, recorded and followed up. 4. Are due to poor quality of components or systems. However, the results show that many of the common failures fall into several different categories and therefore, different types of measures must be taken to improve the operational reliability of residential heat pumps. The interviews tell that failures often are caused by poor installation, neglected maintenance and surveillance, and poor quality of standard components or that components are used outside their declared operating range. The quality of the installations could be improved by increasing installers' knowledge about heat pumps and by requiring that an installation protocol shall be filled-in. It is also important that the owner of the heat pump performs the preventive maintenance recommended by the

  10. Precise alignment of a longitudinal Pockels Cell for Q-switch operation Nd:YAG laser

    International Nuclear Information System (INIS)

    Nisperuza, D.; Botero, G.; Bastidas, A.

    2009-01-01

    The failure to accurately center optical components may, especially in the case of high gain of the Nd:YAG lasers, produce strong parasitic off-axis laser action capable of causing severe component damage typically to the Pockels cell. We report a precise longitudinal alignment of the Pockels cell by modulating the laser polarization using an experimental setup of circular dichroism. This procedure is based on the use of an analyzer at 0 o or 45 o of the Pockels cell axes, and it allows us to adjust the Q-switching delay for best pulse shape, maximum output energy and to reduce the lack of symmetry of the spot laser considerably. (Author)

  11. Post-test characterization of a solid oxide fuel cell stack operated for more than 30,000 hours: The cell

    Science.gov (United States)

    Menzler, Norbert H.; Sebold, Doris; Guillon, Olivier

    2018-01-01

    A four-layer solid oxide fuel cell stack with planar anode-supported cells was operated galvanostatically at 700 °C and 0.5Acm-2 for nearly 35,000 h. One of the four planes started to degrade more rapidly after ∼28,000 h and finally more progressively after ∼33,000 h. The stack was then shut down and a post-test analysis was carefully performed. The cell was characterized with respect to cathodic impurities and clarification of the reason(s) for failure. Wet chemical analysis revealed very low chromium incorporation into the cathode. However, SEM and TEM observations on polished and fractured surfaces showed catastrophic failure in the degraded layer. The cathode-barrier-electrolyte cell layer system delaminated from the entire cell over large areas. The source of delamination was the formation of a porous, sponge-like secondary phase consisting of zirconia, yttria and manganese (oxide). Large secondary phase islands grew from the electrolyte-anode interface towards the anode and cracked the bonding between both layers. The manganese originated from the contact or protection layers used on the air side. This stack result shows that volatile species - in this case manganese - should be avoided, especially when long-term applications are envisaged.

  12. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains a minimum of 70 citations and includes a subject term index and title list.)

  13. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  14. Integration of Aqueous Two-Phase Extraction as Cell Harvest and Capture Operation in the Manufacturing Process of Monoclonal Antibodies

    Directory of Open Access Journals (Sweden)

    Axel Schmidt

    2017-12-01

    Full Text Available Substantial improvements have been made to cell culturing processes (e.g., higher product titer in recent years by raising cell densities and optimizing cultivation time. However, this has been accompanied by an increase in product-related impurities and therefore greater challenges in subsequent clarification and capture operations. Considering the paradigm shift towards the design of continuously operating dedicated plants at smaller scales—with or without disposable technology—for treating smaller patient populations due to new indications or personalized medicine approaches, the rising need for new, innovative strategies for both clarification and capture technology becomes evident. Aqueous two-phase extraction (ATPE is now considered to be a feasible unit operation, e.g., for the capture of monoclonal antibodies or recombinant proteins. However, most of the published work so far investigates the applicability of ATPE in antibody-manufacturing processes at the lab-scale and for the most part, only during the capture step. This work shows the integration of ATPE as a combined harvest and capture step into a downstream process. Additionally, a model is applied that allows early prediction of settler dimensions with high prediction accuracy. Finally, a reliable process development concept, which guides through the necessary steps, starting from the definition of the separation task to the final stages of integration and scale-up, is presented.

  15. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  16. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  17. Retailing residential electricity : A concept that makes sense?

    International Nuclear Information System (INIS)

    MacDonald, C.

    2003-07-01

    A heated debate centres around the deregulation of the electricity industry and the retailing of residential electricity. An assessment of the current situation in the industry was provided in this paper to provide a basis for discussion. The experience gained both in Alberta and Texas in residential retail was examined. The main issue of concern is whether residential customers will benefit from deregulation of the electricity sector. The Retail Energy Deregulation (RED) Index provides a benchmark for those jurisdictions considering the residential options. Deregulation has not led to significant benefits to residential customers in most jurisdictions. The electricity industry will always require a central dispatch/market process that will have to designed, governed, regulated, modified regularly. The benefits to residential consumers are not expected for a very long time. Standard market design is an issue that will require attention. refs., 7 figs

  18. Alternate switching between microbial fuel cell and microbial electrolysis cell operation as a new method to control H2O2 level in Bioelectro-Fenton system

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Wang, Yong; Angelidaki, Irini

    2015-01-01

    cell (MEC) and microbial fuel cell (MFC) mode of operation was developed to meet the challenges. In the MEC mode, a bioelectrochemical system (BES) produces H2O2 which reacts with Fenton's reagent (Fe II) to form hydroxyradical. The unused H2O2 (residual H2O2) is removed as electron acceptor...... by switching the system to MFC mode of operation. Complete decolorization and mineralization of 50 mg L−1 methylene blue (MB) was achieved in the MEC mode with apparent first order rate constants of 0.43 and 0.22 h−1, respectively. After switching to the MFC mode, residual H2O2 of 180 mg L−1 was removed...... at a removal rate of 4.61 mg L−1 h−1 while generating a maximum current density of 0.49 A m−2. The MB degradation and residual H2O2 removal were affected by external resistance, cathode pH and initial MB concentration. Furthermore, the system performance was enhanced under stack operation. This study provides...

  19. Device operation of conjugated polymer/zinc oxide bulk heterojunction solar cells

    NARCIS (Netherlands)

    Koster, L. Jan Anton; van Strien, Wouter J.; Beek, Waldo J. E.; Blom, Paul W. M.

    2007-01-01

    Solar cells based on a poly (p-phenylene vinylene) (PPV) derivative and zinc oxide nanoparticles can reach a power conversion efficiency of 1.6%. The transport of electrons and holes in these promising devices is characterized and it is found that the electron mobility is equal to 2.8 x 10(-9) m(2)

  20. Improving the Operational Stability of PBDTTTz-4 Polymer Solar Cells Modules by Electrode Modification

    DEFF Research Database (Denmark)

    Roth, Bérenger; Benatto, Gisele Alves dos Reis; Corazza, Michael

    2016-01-01

    PBDTTTz-4 is employed in the ambient manufacturing of fully Roll-to-Roll organic solar cell modules. Modules are manufactured using a novel silver nanowire electrode or a previously reported carbon electrode. The average PCE of carbon modules (3.07%) and AgNW modules (1.46%) shows that PBDTTTz-4...

  1. Test Plan for Long-Term Operation of a Ten-Cell High Temperature Electrolysis Stack

    International Nuclear Information System (INIS)

    James E. O'Brien; Carl M. Stoots; J. Stephen Herring

    2008-01-01

    This document defines a test plan for a long-term (2500 Hour) test of a ten-cell high-temperature electrolysis stack to be performed at INL during FY09 under the Nuclear Hydrogen Initiative. This test was originally planned for FY08, but was removed from our work scope as a result of the severe budget cuts in the FY08 NHI Program. The purpose of this test is to evaluate stack performance degradation over a relatively long time period and to attempt to identify some of the degradation mechanisms via post-test examination. This test will be performed using a planar ten-cell Ceramatec stack, with each cell having dimensions of 10 cm x 10 cm. The specific makeup of the stack will be based on the results of a series of shorter duration ten-cell stack tests being performed during FY08, funded by NGNP. This series of tests was aimed at evaluating stack performance with different interconnect materials and coatings and with or without brazed edge rails. The best performing stack from the FY08 series, in which five different interconnect/coating/edge rail combinations were tested, will be selected for the FY09 long-term test described herein

  2. Idiotypic networks incorporating T-B cell co-operation. The conditions for percolation

    NARCIS (Netherlands)

    Boer, R.J. de; Hogeweg, P.

    1989-01-01

    Previous work was concerned with symmetric immune networks of idiotypic interactions amongst B cell clones. The behaviour of these networks was contrary to expectations. This was caused by an extensive percolation of idiotypic signals. Idiotypic activation was thus expected to affect almost all

  3. Granular cell tumour of the neurohypophysis: a rare sellar tumour with specific radiological and operative features.

    LENUS (Irish Health Repository)

    Aquilina, K

    2012-02-03

    Symptomatic granular cell tumours of the neurohypophysis are rare sellar lesions. Preoperative prediction of the diagnosis on the basis of radiological appearance is useful as these tumours carry specific surgical difficulties. This is possible when the tumour arises from the pituitary stalk, rostral to a normal pituitary gland. This has not been emphasized previously.

  4. Characteristics and quality of intra-operative cell salvage in paediatric scoliosis surgery.

    Science.gov (United States)

    Perez-Ferrer, A; Gredilla-Díaz, E; de Vicente-Sánchez, J; Navarro-Suay, R; Gilsanz-Rodríguez, F

    2016-02-01

    To determine the haematological and microbiological characteristics of blood recovered by using a cell saver with a rigid centrifuge bowl (100ml) in paediatric scoliosis surgery and to determine whether it conforms to the standard expected in adult patients. A cross-sectional, descriptive cohort study was performed on 24 consecutive red blood cell (RBC) units recovered from the surgical field and processed by a Haemolite® 2+ (Haemonetics Corp., Braintree, MA, EE. UU.) cell saver. Data were collected regarding age, weight, surgical approach (anterior or posterior), processed shed volume and volume of autologous RBC recovered, full blood count, and blood culture obtained from the RBC concentrate, and incidence of fever after reinfusion. The processed shed volume was very low (939±569ml) with high variability (coefficient of variation=0.6), unlike the recovered volume 129±50ml (coefficient of variation=0.38). A statistically significant correlation between the processed shed volume and recovered RBC concentrate haematocrit was found (Pearson, r=.659, P=.001). Haematological parameters in the recovered concentrate were: Hb 11±5.3g dl(-1); haematocrit: 32.1±15.4% (lower than expected); white cells 5.34±4.22×103 ul(-)1; platelets 37.88±23.5×103 ul(-1) (mean±SD). Blood culture was positive in the RBC concentrate recovered in 13 cases (54.2%) in which Staphylococcus coagulase (-) was isolated. Cell salvage machines with rigid centrifuge bowls (including paediatric small volume) do not obtain the expected haematocrit if low volumes are processed, and therefore they are not the best choice in paediatric surgery. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Results of two years' operation of the waste processing cell PROLIXE

    International Nuclear Information System (INIS)

    Lecomte, M.; Madic, C.; Broudic, J.C.

    1990-01-01

    Solid wastes, contaminated by alpha, beta, gamma radioisotopes, are produced by spent fuel reprocessing and isotope production. The PROLIXE plant, prototype for leaching and encapsulation was put into operation in March 1988 for waste management with the following aims: development of decontamination by oxidative leaching of alpha wastes, to obtain less than 0.1 Ci/t for surface storage; recycling radioactive isotope recovered especially transuranium elements; define a versatile process for various solid radioactive waste for an industrial plant [fr

  6. A Smart Power Electronic Multiconverter for the Residential Sector.

    Science.gov (United States)

    Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva

    2017-05-26

    The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it.

  7. Performance evaluation of integrated fuel processor for residential PEMFCs application

    International Nuclear Information System (INIS)

    Yu Taek Seo; Dong Joo Seo; Young-Seog Seo; Hyun-Seog Roh; Wang Lai Yoon; Jin Hyeok Jeong

    2006-01-01

    KIER has been developing the natural gas fuel processor to produce hydrogen rich gas for residential PEMFCs system. To realize a compact and high efficiency, the unit processes of steam reforming, water gas shift, and preferential oxidation are chemically and physically integrated in a package. Current fuel processor designed for 1 kW class PEMFCs shows thermal efficiency of 78% as a HHV basis with methane conversion of 90% at rated load operation. CO concentration below 10 ppm in the produced gas is achieved with preferential oxidation unit using Pt and Ru based catalyst under the condition of [O 2 ]/[CO]=2.0. The partial load operation have been carried out to test the performance of fuel processor from 40% to 80% load, showing stable methane conversion and CO concentration below 10 ppm. The durability test for the daily start-stop and 8 hr operation procedure is under investigation and shows no deterioration of its performance after 40 start-stop cycles. (authors)

  8. Implementation of a Digital Mock-up for Remote Hot cell Operations

    International Nuclear Information System (INIS)

    Park, Hee Seong; Park, Byung Suk; Kim, Sung Hyun; Kim, Ki Ho; Kim, Ho Dong

    2010-01-01

    A remote manipulation environment that a human operator has to observe is the inner side of a hotcell through a lead grass window which has many obstacles due to many existing 'blind-spots' where are several cameras installed. The lack of visual information when operating in a cluttered environment makes manoeuvering a manipulator very difficult and when this situation is exacerbated by strict time limits for a task completion, then a manipulator and environmental collisions and resultant damage can occur. To cope with these problems, there has been efforts to develop a virtual simulator to validate control programs visually and to establish maintainability-engineering tools that automate generation assembly/disassembly procedures by using Computer Aided Design(CAD) visualization systems with human figure models to virtual reality systems where engineers can interact with the system using virtual input devices. This article introduces a system that can simulate a deployment analysis on a digital mock-up effectively and proposes a scheme to enable an operator to improve a remote manipulation by using a haptic device

  9. Simulation of a tubular solid oxide fuel cell stack using AspenPlusTM unit operation models

    International Nuclear Information System (INIS)

    Zhang, W.; Croiset, E.; Douglas, P.L.; Fowler, M.W.; Entchev, E.

    2005-01-01

    The design of a fuel cell system involves both optimization of the fuel cell stack and the balance of plant with respect to efficiency and economics. Many commercially available process simulators, such as AspenPlus TM , can facilitate the analysis of a solid oxide fuel cell (SOFC) system. A SOFC system may include fuel pre-processors, heat exchangers, turbines, bottoming cycles, etc., all of which can be very effectively modelled in process simulation software. The current challenge is that AspenPlus TM or any other commercial process simulators do not have a model of a basic SOFC stack. Therefore, to enable performing SOFC system simulation using one of these simulators, one must construct an SOFC stack model that can be implemented in them. The most common approach is to develop a complete SOFC model in a programming language, such as Fortran, Visual Basic or C++, first and then link it to a commercial process simulator as a user defined model or subroutine. This paper introduces a different approach to the development of a SOFC model by utilizing existing AspenPlus TM functions and existing unit operation modules. The developed ''AspenPlus TM SOFC'' model is able to provide detailed thermodynamic and parametric analyses of the SOFC operation and can easily be extended to study the entire power plant consisting of the SOFC and the balance of plant without the requirement for linking with other software. Validation of this model is performed by comparison to a Siemens-Westinghouse 100 kW class tubular SOFC stack. Sensitivity analyses of major operating parameters, such as utilization factor (U f ), current density (I c ) and steam-carbon ratio (S/C), were performed using the developed model, and the results are discussed in this paper

  10. Cost related sensitivity analysis for optimal operation of a grid-parallel PEM fuel cell power plant

    Science.gov (United States)

    El-Sharkh, M. Y.; Tanrioven, M.; Rahman, A.; Alam, M. S.

    Fuel cell power plants (FCPP) as a combined source of heat, power and hydrogen (CHP&H) can be considered as a potential option to supply both thermal and electrical loads. Hydrogen produced from the FCPP can be stored for future use of the FCPP or can be sold for profit. In such a system, tariff rates for purchasing or selling electricity, the fuel cost for the FCPP/thermal load, and hydrogen selling price are the main factors that affect the operational strategy. This paper presents a hybrid evolutionary programming and Hill-Climbing based approach to evaluate the impact of change of the above mentioned cost parameters on the optimal operational strategy of the FCPP. The optimal operational strategy of the FCPP for different tariffs is achieved through the estimation of the following: hourly generated power, the amount of thermal power recovered, power trade with the local grid, and the quantity of hydrogen that can be produced. Results show the importance of optimizing system cost parameters in order to minimize overall operating cost.

  11. On direct internal methane steam reforming kinetics in operating solid oxide fuel cells with nickel-ceria anodes

    Science.gov (United States)

    Thallam Thattai, A.; van Biert, L.; Aravind, P. V.

    2017-12-01

    Major operating challenges remain to safely operate methane fuelled solid oxide fuel cells due to undesirable temperature gradients across the porous anode and carbon deposition. This article presents an experimental study on methane steam reforming (MSR) global kinetics for single operating SOFCs with Ni-GDC (gadolinium doped ceria) anodes for low steam to carbon (S/C) ratios and moderate current densities. The study points out the hitherto insufficient research on MSR global and intrinsic kinetics for operating SOFCs with complete Ni-ceria anodes. Further, it emphasizes the need to develop readily applicable global kinetic models as a subsequent step from previously reported state-of-art and complex intrinsic models. Two rate expressions of the Power law (PL) and Langmuir-Hinshelwood (LH) type have been compared and based on the analysis, limitations of using previously proposed rate expressions for Ni catalytic beds to study MSR kinetics for complete cermet anodes have been identified. Firstly, it has been shown that methane reforming on metallic (Ni) current collectors may not be always negligible, contrary to literature reports. Both PL and LH kinetic models predict significantly different local MSR reaction rate and species partial pressure distributions along the normalized reactor length, indicating a strong need for further experimental verifications.

  12. The drivers to adopt renewable energy among residential users.

    Science.gov (United States)

    Rahman, Zahari Abdul; Elinda, Esa

    2016-03-01

    This study aims to examine the drivers to adopt renewable energy (RE) among residential users in Malaysia. Based on the theoretical framework of a consumer’s decision making process, an empirical study of the adoption of RE was conducted. A total of 501 residential users were used in this study. This study proved that perceived utility of new technology, perceived utility of new service, and perceived benefit of new technology are the drivers to adopt RE among residential users. These factors are knowing crucial to RE suppliers and producers because it will generates more demand from the residential users and the percentage of energy mix from RE sources can be increase.

  13. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  14. Design and Implementation of an Innovative Residential PV System

    Science.gov (United States)

    Najm, Elie Michel

    This work focuses on the design and implementation of an innovative residential PV system. In chapter one, after an introduction related to the rapid growth of solar systems' installations, the most commonly used state of the art solar power electronics' configurations are discussed, which leads to introducing the proposed DC/DC parallel configuration. The advantages and disadvantages of each of the power electronics' configurations are deliberated. The scope of work in the power electronics is defined in this chapter to be related to the panel side DC/DC converter. System integration and mechanical proposals are also within the scope of work and are discussed in later chapters. Operation principle of a novel low cost PV converter is proposed in chapter 2. The proposal is based on an innovative, simplified analog implementation of a master/slave methodology resulting in an efficient, soft-switched interleaved variable frequency flybacks, operating in the boundary conduction mode (BCM). The scheme concept and circuit configuration, operation principle and theoretical waveforms, design equations, and design considerations are presented. Furthermore, design examples are also given, illustrating the significance of the newly derived frequency equation for flybacks operating in BCM. In chapters 3, 4, and 5, the design implementation and optimization of the novel DC/DC converter illustrated in chapter 2 are discussed. In chapter 3, a detailed variable frequency BCM flyback design model leading to optimizing the component selections and transformer design, detailed in chapter 4, is presented. Furthermore, in chapter 4, the method enabling the use of lower voltage rating switching devices is also discussed. In chapter 5, circuitry related to Start-UP, drive for the main switching devices, zero-voltage-switching (ZVS) as well as turn OFF soft switching and interleaving control are fully detailed. The experimental results of the proposed DC/DC converter are presented in

  15. Effectiveness of paper-structured catalyst for the operation of biodiesel-fueled solid oxide fuel cell

    Science.gov (United States)

    Quang-Tuyen, Tran; Kaida, Taku; Sakamoto, Mio; Sasaki, Kazunari; Shiratori, Yusuke

    2015-06-01

    Mg/Al-hydrotalcite (HDT)-dispersed paper-structured catalyst (PSC) was prepared by a simple paper-making process. The PSC exhibited excellent catalytic activity for the steam reforming of model biodiesel fuel (BDF), pure oleic acid methyl ester (oleic-FAME, C19H36O2) which is a mono-unsaturated component of practical BDFs. The PSC exhibited fuel conversion comparable to a pelletized catalyst material, here, conventional Ni-zirconia cermet anode for solid oxide fuel cell (SOFC) with less than one-hundredth Ni weight. Performance of electrolyte-supported cell connected with the PSC was evaluated in the feed of oleic-FAME, and stable operation was achieved. After 60 h test, coking was not observed in both SOFC anode and PSC.

  16. Operating Point Optimization of a Hydrogen Fueled Hybrid Solid Oxide Fuel Cell-Steam Turbine (SOFC-ST Plant

    Directory of Open Access Journals (Sweden)

    Juanjo Ugartemendia

    2013-09-01

    Full Text Available This paper presents a hydrogen powered hybrid solid oxide fuel cell-steam turbine (SOFC-ST system and studies its optimal operating conditions. This type of installation can be very appropriate to complement the intermittent generation of renewable energies, such as wind generation. A dynamic model of an alternative hybrid SOFC-ST configuration that is especially suited to work with hydrogen is developed. The proposed system recuperates the waste heat of the high temperature fuel cell, to feed a bottoming cycle (BC based on a steam turbine (ST. In order to optimize the behavior and performance of the system, a two-level control structure is proposed. Two controllers have been implemented for the stack temperature and fuel utilization factor. An upper supervisor generates optimal set-points in order to reach a maximal hydrogen efficiency. The simulation results obtained show that the proposed system allows one to reach high efficiencies at rated power levels.

  17. Main maintenance operations for Test Blanket Systems in ITER TBM port cells

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Cortes, P.; Friconneau, J.-P.; Giancarli, L.M.; Gotewal, K.K.; Iseli, M.; Kim, B.Y.; Levesy, B.; Martins, J.-P.; Merola, M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Nevière, J.-C. [Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Siarras, A. [Sogetti, Parc de la Duranne, 13857 Aix-en-Provence (France); Tesini, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: • The Test Blanket System components layout in Port Cell room is described. • The maintenance of the two Test Blanket Systems in ITER port cell is addressed. • The overall replacement/maintenance strategy is defined. • The main maintenance tasks of the systems are discussed. • The maintenance strategy and required tools are presented. -- Abstract: Each Test Blanket System in ITER is formed by an in-vessel component, the Test Blanket Module, and several associated ancillary systems (coolant and Tritium systems, instrumentation and control systems). The paper describes the overall replacement/maintenance strategy and the main maintenance tasks that have to be considered in the design of the systems. It shows that there are no critical issues.

  18. Characterization of the Darwin direct implicit particle-in-cell method and resulting guidelines for operation

    International Nuclear Information System (INIS)

    Gibbons, M.R.; Hewett, D.W.

    1997-01-01

    We investigate the linear dispersion and other properties of the Darwin Direct Implicit Particle-in-cell (DADIPIC) method in order to deduce guidelines for its use in the simulation of long time-scale, kinetic phenomena in plasmas. The Darwin part of this algorithm eliminates the Courant constraint for light propagation across a grid cell in a time step and divides the field solution into several elliptic equations. The direct implicit method is only applied to the electrostatic field relieving the need to resolve plasma oscillations. Linear theory and simulations verifying the theory are used to generate the desired guidelines as well as show the utility of DADIPIC for a wide range of low frequency, electromagnetic phenomena. We find that separation of the fields has made the task of predicting algorithm behavior easier and produced a robust method without restrictive constraints. 20 refs., 11 figs., 3 tabs

  19. Startup, testing, and operation of the Santa Clara 2MW direct carbonate fuel cell demonstration plant

    Energy Technology Data Exchange (ETDEWEB)

    Skok, A.J.; Leo, A.J. [Fuel Cell Engineering Corp., Danbury, CT (United States); O`Shea, T.P. [Santa Clara Demonstration Project, CA (United States)

    1996-12-31

    The Santa Clara Demonstration Project (SCDP) is a collaboration between several utility organizations, Fuel Cell Engineering Corporation (FCE), and the U.S. Dept. Of Energy aimed at the demonstration of Energy Research Corporation`s (ERC) direct carbonate fuel cell (DFC) technology. ERC has been pursuing the development of the DFC for commercialization near the end of this decade, and this project is an integral part of the ERC commercialization effort. The objective of the Santa Clara Demonstration Project is to provide the first full, commercial scale demonstration of this technology. The approach ERC has taken in the commercialization of the DFC is described in detail elsewhere. An aggressive core technology development program is in place which is focused by ongoing interaction with customers and vendors to optimize the design of the commercial power plant. ERC has selected a 2.85 MW power plant unit for initial market entry. Two ERC subsidiaries are supporting the commercialization effort: the Fuel Cell Manufacturing Corporation (FCMC) and the Fuel Cell Engineering Corporation (FCE). FCMC manufactures carbonate stacks and multi-stack modules, currently from its production facility in Torrington, CT. FCE is responsible for power plant design, integration of all subsystems, sales/marketing, and client services. FCE is serving as the prime contractor for the design, construction, and testing of the SCDP Plant. FCMC has manufactured the multi-stack submodules used in the DC power section of the plant. Fluor Daniel Inc. (FDI) served as the architect-engineer subcontractor for the design and construction of the plant and provided support to the design of the multi-stack submodules. FDI is also assisting the ERC companies in commercial power plant design.

  20. Global considerations on fuel cells for mobile and domestic operation connected to the AC-line

    Energy Technology Data Exchange (ETDEWEB)

    Rufer, A.; Favrat, D.; Mc Evoy, A. [Ecole Polytechnique Federale, LEI, LENI, ICP, Lausanne (Switzerland)

    2000-07-01

    Three labs at EPFL which are bound through CRETE (Centre de Recherche et d'Enseignement en Technologies Energetiques) have oriented some of their research activities on integrated fuel cells equipment. Technological and systemic optimization research programs are currently under way, mainly in the field of electro-chemical materials, of systemic approach, and in the field of optimising the static conversion system for injection in an electrical network. Efficiency calculations and comparisons are given.