WorldWideScience

Sample records for caso4 dy tld

  1. Effects of phosphor proportion and grain size on photon energy response of CaSO4:Dy teflon TLD discs

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Bhatt, R.C.

    1979-01-01

    Effects of phosphor proportion and grain size on the photon energy dependence of CaSO 4 :Dy embedded teflon TLD discs have been studied. It was found that in the commonly used TLD disc compositions, the proportion of phosphor has only little effect on energy dependence. This dependence could be significantly reduced by using phosphor of grain size less than 1 μm. The experimental results are compared with calculated results. (Auth.)

  2. Formation of rod type structures of CaSO4: Ce,P,Dy TLD phosphor using different synthesis routes

    International Nuclear Information System (INIS)

    Atone, M.S.; Wani, J.A.; Dhoble, S.J.

    2011-01-01

    Effect of Ce and P co-activation in CaSO 4 : Dy, standard TLD phosphor prepared by different synthesis root techniques and it's structural morphology is reported first time in this paper. We have already reported the sensitization of luminescence in CaSO 4 : Dy with phosphorous (P) and cerium (Ce) ions separately via acid distillation route. In the current investigation, we have doped these impurities (Ce, P, Dy) simultaneously in CaSO 4 host lattice. We have employed a well known chemical precipitation method and modified acid distillation method and have attempted to analyse the surface morphology resulted from these two synthesis routes. Chemical precipitation usually takes place at room temperature and in this way allows the reaction to take place silently. In case of acid distillation method we have reduced the synthesis temperature to 493K which is considerably less than 653K employed in previously reported literature. In case of precipitation method particle shape seems to be spherical and particle size is around one micro range or in the neighbourhood of nanorange. However, in the case of modified acid distillation method particles have shaped in to rod like structures and particle size again falls in the micro range. The photoluminescence intensity of the phosphor prepared by chemical precipitation method is weak as compared to the phosphor prepared by modified acid distillation method. Both the phosphors prepared by different methods have shown characteristic transitions of dopants. The emission spectra of prepared phosphors at 309 nm and 329 nm of Ce 3+ ions overlap well with excitation of Dy 3+ ions. Thermoluminescence (TL) property of both phosphors is again good though certain variation is observed in case of phosphor prepared by modified acid distillation method which shows rod like structure of phosphor. This variation in TL may be attributed to change in surface morphology (formation of rod type structure of particles) of the phosphor. (author)

  3. Beta response of CaSO4:Dy based TLD badge and its angular dependence studies for personnel monitoring applications

    International Nuclear Information System (INIS)

    Kumar, Munish; Rakesh, R.B.; Sneha, C.; Ratna, P.; Bakshi, A.K.; Datta, D.

    2016-01-01

    In India, shallow/skin doses received by radiation workers from beta particles are measured using CaSO 4 :Dy based Teflon embedded TLD badge. The beta particles having maximum energy E max > 0.6 MeV - ≥ 3.54 MeV are monitored. The ratio of the response of discs under open and plastic regions (D Open/ D Perspex ) is used to estimate the energy of the beta source and to apply response correction factor. This is required as the disc dosimeters are thick and exhibit energy dependent response. Due to lack of comprehensive information regarding disc ratios and associated beta multiplication/response correction factors, present study was performed

  4. Design of photon energy compensation filters for the new four element CaSO4:Dy TLD badge

    International Nuclear Information System (INIS)

    Mishra, D.R.; Kulkarni, M.S.; Pradeep, Ratna; Kannan, S.

    2001-01-01

    A new four element TLD badge using CaSO 4 :Dy is being developed for the estimation of personal dose equivalents Hp(10) and Hp(0.07) and to discriminate them in the mix field (low energy x-ray and high energy γ-ray). Design of energy compensation filters for the new TLD badge is discussed. The total metal filter thickness is kept less than 1 mm. The first and second elements of the badge are planned to be open and plastic (≅180 gm/cm 2 ) window. For the third element a combination of 0.2 mm Sn + 0.7mm Cu + 0.1 mm Al with mass thickness ≅ 1100 mg/cm 2 is proposed which gives energy dependent response similar to Hp(10) within ± 20% (above 80 keV). For the fourth dosimeter a filter combination of 0.4 mm Al + 0.07 mm Sn is proposed which gives Hp(10)xR response for diagnostic x-rays within ± 10% in the mix field. (author)

  5. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  6. Unusual ratio of TL readouts of different discs of personnel monitoring TLD badge based on CaSO4: Dy teflon disc

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Ande, C.D.; Kher, R.K.; Chourasiya, G.; Vashishtha, R.; Gupta, A.K.

    2005-01-01

    In India Personnel Monitoring against external radiation hazard of gamma, beta and X-rays is provided using a TLD badge based on CaSO 4 : Dy Teflon TLD disc. Unusual ratios of TL readouts of different discs of TLD badge (Disc Ratios) observed for service TLD badges of radiation workers were investigated and simulated. Simulations were carried out by exposure of TLD badges by speck type radioactive sources placed in contact of badges, exposure of TLD badges placed on concrete floor to a radiography source. Clues for the simulation were obtained from nature of work, radiological conditions during course of individuals' work whose TLD badges showed the unusual disc ratios and geometrical calculations performed. It is concluded that although the actual exposure condition during use is unknown, the unusual disk ratios observed for the service TLD badges can be simulated and utilized to arrive at probable exposure conditions. The study helped in investigations of the abnormal exposures and assigning doses to the concerned radiation workers. (author)

  7. Metal filters for the compensation of photon energy dependence of the response of CaSO4: Dy - Teflon TLD Discs

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Bhatt, R.C.

    1979-01-01

    Metal filters of aluminium, stainless steel, copper, cadmium, tin and lead were studied for compensation of the photon energy dependence of the response of CaSO 4 : Dy Teflon TLD Discs. It was found that metals such as cadmium and tin (which are normally used for this purpose) with their K absorption edges around 30 keV, are poor compensators of photon energy dependence. However, if either cadmium or tin is used in combination with either copper or stainless steel (with the lower Z filter nearer to the TLD dosimeter disc) a better compensation of photon energy dependence is achieved. Consequently, for personnel monitoring of X and gamma radiations, a TLD badge with CaSO 4 : Dy Teflon TLD discs and two sets of combination filters has been recommended. In the range of 27 keV -1.25 MeV this badge offers a photon energy response which varies within +-15%. This is a considerable improvement on the corresponding limits of +-65% on using a single filter. (orig.)

  8. Performance evaluation of vertical feed fully automated TLD badge reader using 0.8 and 0.4 mm teflon embedded CaSO4:Dy dosimeters

    International Nuclear Information System (INIS)

    Ratna, P.; More, Vinay; Kulkarni, M.S.

    2012-01-01

    The personnel monitoring of more than 80,000 radiation workers in India is at present carried out by semi-automated TLD badge Reader systems (TLDBR-7B) developed by Radiation Safety Systems Division, Bhabha Atomic Research Centre. More than 60 such reader systems are in use in all the personnel monitoring centers in the country. Radiation Safety Systems Division also developed the fully automated TLD badge reader based on a new TLD badge having built-in machine readable ID code (in the form of 16x3 hole pattern). This automated reader is designed with minimum of changes in the electronics and mechanical hardware in the semiautomatic version (TLDBR-7B) so that such semi-automatic readers can be easily upgraded to the fully automated versions by using the new TLD badge with ID code. The reader was capable of reading 50 TLD cards in 90 minutes. Based on the feedback from the users, a new model of frilly automated TLD badge Reader (model VEFFA-10) is designed which is an improved version of the previously reported fully Automated TLD badge reader. This VEFFA-10 PC based Reader incorporates vertical loading of TLD bards having machine readable ID code. In this new reader, a vertical rack, which can hold 100 such cards, is mounted from the right side of the reader system. The TLD card falls into the channel by gravity from where it is taken to the reading position by rack and pinion method. After the readout, the TLD card is dropped in a eject tray. The reader employs hot N 2 gas heating method and the gas flow is controlled by a specially designed digital gas flow meter on the front panel of the reader system. The system design is very compact and simple and card stuck up problem is totally eliminated in the reader system. The reader has a number of self-diagnostic features to ensure a high degree of reliability. This paper reports the performance evaluation of the Reader using 0.4 mm thick Teflon embedded CaSO 4 :Dy TLD cards instead of 0.8 mm cards

  9. Feasibility study on using three element TLD badge based on CaSO4:Dy as environmental dosimeter

    International Nuclear Information System (INIS)

    Choudhary, Sreeletha; BharathiLashmi, G.V.; Yasotha, E.; Devanathan, P.S.; Annalakshmi, O.; Mathiyarasu, R.

    2018-01-01

    A three element thermoluminescence badge based on CaSO 4 :Dy is used for personnel monitoring in India. The three discs of the badge is heated in sequential manner by hot nitrogen gas and from the amount of light emitted while heating, the doses are estimated. This badge was redesigned as a two element system and is used for environmental monitoring. Though the two element badge has some advantages, the software used for processing of TLDs in the semiautomatic reader has to be modified and separate badges has to be maintained for environmental dose measurements. In this work a feasibility study has been carried out to use the three element personnel monitoring badge itself for environmental monitoring also. This study was also carried out to understand the abnormal pattern of the glow curves observed in some field cards

  10. Hand book on the use of TLD badge based on CaSO4:Dy teflon TLD discs for individual monitoring

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Adtani, M.M.; Varadharajan, G.; Bakshi, A.K.; Srivastava, Kshama; Bihari, R.R.

    2002-10-01

    Individual monitoring is one of the most important aspects of a radiation protection programme. In India, an official and centralized personnel monitoring service to radiation workers started in 1952. With the indigenous development of a TLD badge system in 1975 at Bhabha Atomic Research Centre, decentralization of monitoring service was initiated. At present, about 40,000 radiation workers are monitored using this system through twelve TLD units located in different parts of the country, including a private accredited laboratory. Regulatory and other inspecting bodies have often asked outstation TLD units to produce a duly approved document on the procedures being practiced for the assessment of personal doses. A need for such a document has also been felt to ensure the uniformity in processing of dosemeters, recording and reporting of doses by different TLD units and to provide guidelines regarding the infrastructure requirement. This document in the form of a handbook has been prepared to cater to the above needs. The handbook is expected to provide necessary guidelines not only to the newcomers/ forthcoming units and the existing laboratories but also to help the regulators, inspectors and assessors. (author)

  11. The study on production of CaSO4 (Dy) dosimeters

    International Nuclear Information System (INIS)

    Sriratchatchaval, V.

    1989-05-01

    The purpose of this experiment is to find out the techniques of preparation and production and to study the characteristic of Thermoluminescence Dosimeter (TLD); CaSO 4 (Dy). This dosimeter is produced as pellets with 1.0 mm thickness and diameter 4.8 mm, which is suitable for gamma rays and X-rays detector. CeSO 4 (Dy) is prepared by adding Dy 2 O 3 (0.2 mole %Dy) to CaSO 4 .2H 2 O then taking this mixture to crystallize in conc. H 2 SO 4 at 300 0 C responds linearly to gamma rays in the range of 0.01-100 mGy and gives the highest peak at 205 0 C. This TLD is fading 3% per month, low sensitivity to light and the response of signal depends on the energy level of gamma rays

  12. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  13. Environmental monitoring by CaSO4:Dy TL dosimeters

    International Nuclear Information System (INIS)

    Deme, S.; Szabo, P.P.

    1975-12-01

    The thermoluminescent dosimeters of high sensitivity are useful for monitoring the area near nuclear installations. CaSO 4 :Dy TL dosimeters have high sensitivity and low fading so that by means of them the dose from the background can be measured with an accuracy of 10-20%. An increase of 2 mR in the background can be observed and doses as high as 1000R can be registered with an accuracy of 5%. The measuring method and results are reported here. For two years these CaSO 4 :Dy dosimeters have been successfully used at the site of the Central Research Institute for Physics. (K.A.)

  14. Phototransferred TL studies in CaSO4:Dy

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Kathuria, V.K.; Gangadharan, P.

    1980-01-01

    PTTL studies in CaSO 4 :Dy have revealed two high temperature peaks at 500 and 570 0 C in γ-exposed phosphor. Employing 365 nm for phototransfer at elevated temperature 95 0 C, PTTL can serve a useful technique for re-estimation of the radiation exposure. (author)

  15. Thermoluminescent characteristics of LiF:Mg, Cu, P and CaSO_4:Dy for low dose measurement

    International Nuclear Information System (INIS)

    Del Sol Fernández, S.; García-Salcedo, R.; Mendoza, J. Guzmán; Sánchez-Guzmán, D.; Rodríguez, G. Ramírez; Gaona, E.; Montalvo, T. Rivera

    2016-01-01

    Thermoluminescence (TL) characteristics for LiF:Mg, Cu, P, and CaSO_4:Dy under the homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescence dosimetry are presented. The irradiation were performed utilizing a conventional X-ray equipment installed at the Hospital Juárez Norte of México. Different thermoluminescence characteristics of two material were studied, such as batch homogeneity, glow curve, linearity, detection threshold, reproducibility, relative sensitivity and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and they were positioned in a generic phantom. The dose analysis, verification and comparison with the measurements obtained by the TLD-100 were performed. Results indicate that the dosimetric peak appears at 202 °C and 277.5 °C for LiF:Mg, Cu, P and CaSO_4:Dy, respectively. TL response as a function of X-ray dose showed a linearity behavior in the very low dose range for all materials. However, the TLD-100 is not accurate for measurements below 4 mGy. CaSO_4:Dy is 80% more sensitive than TLD-100 and it show the lowest detection threshold, whereas LiF:Mg, Cu, P is 60% more sensitive than TLD-100. All materials showed very good repeatability. Fading for a period of one month at room temperature showed low fading LiF:Mg, Cu, P, medium and high for TLD-100 and CaSO_4:Dy. The results suggest that CaSO_4:Dy and LiF:Mg, Cu, P are suitable for measurements at low doses used in radiodiagnostic. - Highlights: • Several dosimetric characteristics were evaluated. • TL dose response to very low dose X-rays was studied. • The applications proposed for each material may be useful for diagnostic radiology dosimetry.

  16. CaSO4:DY,Mn: A new and highly sensitive thermoluminescence phosphor for versatile dosimetry

    Science.gov (United States)

    Bahl, Shaila; Lochab, S. P.; Kumar, Pratik

    2016-02-01

    With the advent of newer techniques for dose reduction coupled with the development of more sensitive detectors, the radiation doses in radiological medical investigation are decreasing. Nevertheless, keeping the tenet in mind that all radiation doses could entail risk, there is a need to develop more sensitive dosimeters capable of measuring low doses. This paper gives the account of the development of a new and sensitive phosphor CaSO4:Dy,Mn and its characterization. The standard production procedure based on the recrystallization method was used to prepare CaSO4:Dy,Mn. The Thermoluminescence (TL) studies were carried out by exposing it with gamma radiation (Cs-137) from 10 μGy to 100 Gy. The theoretical studies to determine the number of peaks and kinetic parameters related to the TL glow peaks in CaSO4:Dy,Mn was performed using the Computerized Glow Curve Deconvolution (CGCD) method. Experiments were performed to determine optimum concentration of the dopants Dysprosium (Dy) and Mangnese (Mn) in the host CaSO4 so that maximum sensitivity of the phosphor may be achieved. The optimum dopant concentration turned out to be 0.1 mol%. As there were two dopants Dy and Mn their relative ratio were varied in steps of 0.025 keeping the concentration of total dopant (Dy and Mn) 0.1 mol% always. The maximum TL intensity was seen in the CaSO4:Dy(0.025),Mn(0.075) combination. The TL sensitivity of this phosphor was found to be about 2 and 1.8 times higher than that of popular phosphor CaSO4:Dy and LiF:Mg,Cu,P (TLD-700H) respectively. This new phosphor CaSO4:Dy,Mn showed fading of 11% which is similar to that of the standard phosphor CaSO4:Dy. The paper concludes that the new, highly sensitive TL phosphor CaSO4:Dy,Mn has shown higher sensitivity and hence the potential to replace commonly used CaSO4:Dy.

  17. Thermoluminescent dosemeters of CaSO4: Dy + Teflon

    International Nuclear Information System (INIS)

    Campos, L.L.

    1989-01-01

    The development of a pellet dosemeter of CaSO 4 : Dy + Teflon at the Dosimetric Materials Production Laboratory - IPEN/Brazilian CNEN-SP is presented. The pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. The pellet characteristics from the point of view of dosimetry. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these three filters allows to determine the energy of an unknown source. (author) [pt

  18. Performance of CaSO4:Dy detectors

    International Nuclear Information System (INIS)

    Setti, M.C.; Silva, G.R.; Pela, C.A.; Bruco, J.L.; Borges, J.C.

    2004-01-01

    CaSO 4 :Dy detectors have been used in personal dosimetry. The MRA company recently entered into the market of these detectors. Searching to assure a product quality level that would satisfy its customs most expectancies, MRA programmed several tests to qualify and quantify these detectors main characteristics, before their definitive insertion in the market. Preliminary tests furnished a value of 29,5 ± 1,2 nC for homogeneity and a maximum dispersion of 3 % for linearity . (author)

  19. Thermoluminescence mechanisms in CaSO4:Dy single crystals

    International Nuclear Information System (INIS)

    Morgan, M.D.; Stoebe, T.G.

    1986-01-01

    ESR studies of gamma-irradiated CaSO 4 :Dy have shown, in addition to the usual intrinsic defects, four new paramagnetic centres. An analysis of the g values and the g tensors in conjunction with the anhydrite crystal structure indicate that these centres are related to sulphate ions. Two of these centres (denoted 1a and 3a) are proposed as holes trapped and shared between two adjacent sulphate ions, this structure being stabilised by a neighbouring Ca vacancy. Centre 3b is suggested as a hole associated with one sulphate ion, again stabilised by an adjacent Ca vacancy. Because of the two distinct crystallographic directions in the anhydrite structure, centre 3b was found to consist of two distinguishable defects with slightly differing decay temperatures. The fourth centre appears to be an electron trapping site with structure similar to centre 3b. Decay temperatures of these ESR defects are correlated with the observance of TL peaks in CaSO 4 :Dy. Thermoluminescence studies as a function of impurity content confirmed the presence of calcium vacancies, which are formed during crystal growth, and that they play an important role in the TL process. TL models are proposed to account for the observed properties of CaSO 4 :Dy. (author)

  20. PTFE Additive and Re-annealing Effect on Thermoluminescence Response of CaSO4:Dy Derived from Co-precipitation Method

    Science.gov (United States)

    Nuraeni, Nunung; Dwi Septianto, Ricky; Iskandar, Ferry; Haryanto, Freddy; Waris, Abdul; Hiswara, Eri

    2017-07-01

    Effect of re-annealing treatment in thermoluminescence response of thermoluminescent dosimeter (TLD) CaSO4:Dy and CaSO4:Dy with PTFE (Polytetrafluoroethylene) addition was investigated. CaSO4:Dy was prepared by a co-precipitation method. The PTFE was added before re-annealing treatment which the mass ratio of CaSO4:Dy and PTFE was fixed to 2:3. The re-annealing treatments of the samples were done at temperature 700 °C for 1 hr. The obtained samples were characterized using a Fourier-transform infrared (FTIR) and X-ray diffraction (XRD) to observe the molecule bonding in sample and crystal properties, respectively. From the experimental results, it was observed that the thermoluminescence intensity of CaSO4:Dy, CaSO4:Dy re-annealed at 700 °C, and CaSO4:Dy + PTFE re-annealed at 700 °C are 57.03, 75.15, and 1191.11 nC, respectively. The intensity of 700 °C-re-annealed CaSO4:Dy increased significantly after PTFE addition.

  1. Thermoluminescence properties of home-made CaSO4:Dy For Dosimetry Purposes

    International Nuclear Information System (INIS)

    Kamal, S.M.; Gerges, A.S.; Al-Said, M.A.

    2004-01-01

    Dysprosium doped Calcium Sulfate (CaSO 4 :Dy) had been first prepared by Yamashita in 1968 with method based on acid evaporation in an open system, which pose human health risks, corrosion and pollution to the environment due to sulfuric acid vapor. It has found increasing use in various applications in the field of radiation dosimetry due to their ease of preparation as compared to many other sensitive TL materials. Many researchers emphasized that the grain size and impurities influence the relative intensities of the broad glow peaks as well as overall sensitivities. In this paper, we introduce a new method of preparation for avoiding all of these disadvantages and improving the main TL materials properties, which required for dosimetric use. The main TL characteristics of home-made CaSO 4 :Dy .crystals with different concentrations are investigated alter the preparation and heat treatment conditions. The results indicated a linear response from 5μ .Gy up to 10 Gy with the highest sensitivity obtained at 0.25 mol % and optimum sensitivity at less than 75 jam grain sizes. Three peaks at 137 degree C, 222 degree C and 311 degree C were obtained. We conclude to use our home-made prepared CaSO 4 :Dy with 0.25 mol % concentration for gamma-ray dosimetry as more sensitive and cheaper than commercial phosphor (TLD-900). This will increase the routine and research work in the area of TL dosimetry

  2. Performance tests of a CaSO4:Dy based thermoluminescence personal dosemeter

    International Nuclear Information System (INIS)

    Azorin, J.; Gutierrez, A.; Niewiadomski, T.

    1986-01-01

    In order to replace LiF commercial thermoluminescence dosemeters (TLDs) now used in personnel monitoring, we developed a TLD personnel monitoring badge based on pellets of CaSO 4 :Dy bound in pure KBr placed in plastic holders provided with 0.8 mm Pb filters to compensate for the energy dependence of CaSO 4 :Dy. Performance tests, based on the proposals of international standards for TLDs intended to be used as general deep tissue personal dosemeters, were done by developing the detailed test methods both for the tests required by the International Atomic Energy Agency (fading, linearity, effect of fluorescent light and sunlight and stability under standard climatic conditions) and to meet the requirements of the International Electrotechnical Commission (batch homogeneity, detection threshold, stability of zero point repeatibility and residual). Initial tests showed a high residual and an increase of inhomogeneity. However, these drawbacks were overcome by changing the annealing procedure and the readout conditions. Using these new conditions TLDs met all the requirements for personal dosemeters. (author)

  3. Thermal neutron detection by activation of CaSO4:Dy + KBr thermoluminescent phosphors

    International Nuclear Information System (INIS)

    Gordon, A.M.P.L.; Muccillo, R.

    1979-01-01

    Thermoluminescence (TL) studies to detect thermal neutrons were performed in cold-pressed CaSO 4 :0,1%Dy + KBr samples. The detection is based on the self-irradiation of the CaSO 4 :Dy TL phosphor by the Br isotopes activated by exposure to a mixed neutron-gamma field. (Author) [pt

  4. Gamma ray induced sensitization in CaSO4:Dy and competing trap model

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Kher, R.K.; Gangadharan, P.

    1979-01-01

    Gamma ray induced sensitization in CaSO 4 :Dy has been compared (by measurement of TL glow curves) for different temperatures during irradiation (25 0 , 120 0 and 250 0 C). Enhanced sensitization at elevated temperatures seems to support the competing trap model for supralinearity and sensitization in CaSO 4 :Dy. (author)

  5. Testing of CaSO-4:Dy in teflon discs as a thermoluminescent dosimetry material for personal monitoring of uranium mine and mill workers

    International Nuclear Information System (INIS)

    Boas, J.F.; Murray, A.; Young, J.G.; Johnston, P.N.

    1981-05-01

    Some studies of the spectroscopic and thermoluminescent properties of CaSO 4 :Dy are discussed. Measurements were also made in the field. Exposures measured using TLD, film and spot monitoring were in agreement, and these observations, together with measurements made at various heights above the ore stockpile have shown that CaSO 4 :Dy in teflon discs, shielded by 2mm of copper, give a reliable measure of the exposure at the appropriate position on the wearer's body. This exposure may then be converted into the dose equivalent for the whole body

  6. Preparation of CaSO4:Dy by precipitation method to gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.; Roman, J.; Azorin, J.; Sosa, R.; Guzman, J.; Serrano, A.K.; Garcia, M.; Alarcon, G.

    2010-01-01

    This paper presents the results of the preparation and characterization of dysprosium-doped calcium sulfate (CaSO 4 :Dy) phosphor, which was obtained by homogeneous precipitation from calcium acetate Ca(CH 3 COO - ) 2 . Structural and morphological characteristics were studied using a scanning electronic microscope (SEM). The structure of all compounds was determined by X-ray diffraction method too. Thermoluminescence (TL) emission properties of CaSO 4 :Dy under gamma radiation effects were studied. This phosphor powder presented a TL glow curve with two peaks (Tmax) centered at around of 180 and 300 deg. C, respectively. The TL response of CaSO 4 :Dy as a function of gamma absorbed dose was linear in a wide range. Both emission and excitation spectra were also obtained. Results showed that this new preparation method of CaSO 4 :Dy TL phosphor is less expensive, cleaner and safer than the conventional preparation method.

  7. Thermoluminescent properties of CaSO4:Dy prepared by precipitation method

    International Nuclear Information System (INIS)

    Roman, J.; Rivera, T.; Azorin, J.

    2009-10-01

    This paper reports the synthesis and thermoluminescent (Tl) characterization of CaSO 4 :Dy obtained by the precipitation method. Thermoluminescent CaSO 4 :Dy powder and Teflon (PTFE) were mixed in order to obtain samples in pellets form. Samples of CaSO 4 :Dy were exposed to a radiation gamma source of 60 Co and 90 Sr beta particles. Tl response of CaSO 4 :Dy showed a glow curve with two peaks centered at around 164 and 302 C. Tl phosphor showed a good linearity in the range from 0.5 to 30 Gy. Fading of the Tl information was 5.19 % in 37 days and presented a standard deviation of 4% for reproducibility. (Author)

  8. Development of Thermoluminescence Dosimeter CaSO4:Dy as Personal and Environmental Dosimeters

    International Nuclear Information System (INIS)

    Hasnel Sofyan

    2009-01-01

    Development of personal and environmental dosimeters using material phosphors of CaSO 4 :Dy powder in form capillary glass and disc teflon thermoluminescence (TL) dosimeter have been done. TL dosimeter CaSO 4 :Dy powder used can record dose response less than 0.01 mGy. Fading of TL dosimeter capillary glass after 29 days is 25%. In 1 batch, making of CaSO 4 :Dy powder can obtain 2 groups of dosimeter capillaries with coefficient variance smaller than 10%. This discrepancy caused difference in powder making and reading of the TL dosimeter. TL dosimeter CaSO 4 :Dy teflon disc with dia. 5 mm and 0.8 mm thickness is homogeneous mixture between phosphor powder with dia. 80 to 150 mesh and teflon powder dia. 20 μm. The composition of CaSO 4 :Dy and teflon in TL dosimeter influence sensitivity of the dosimeter. It’ concluded that in order to obtain optimal sensitivity of TL dosimeter, the composition of CaSO 4 :Dy and teflon is 3 and 1 with pressured of disc in 700 MPa. (author).

  9. Thermal behaviour of the thermoluminescent dosemeter CaSO4: Dy + NaCl

    International Nuclear Information System (INIS)

    Antonio Filho, J.

    1988-01-01

    Thermoluminescent materials are widely applied in radiation dosimetry. Nevertheless to obtain a good degree of reliability, it is necessary to subject the materials to an adequate thermal treatment, before and after irradiation, conveniently controlling temperature, heating time and cooling rate. It has been observed that the TLD CaSO 4 : Dy + NaCl loses 10% of its sensivity after each utilization cycle with the thermal treatment usually recomended. This fact establishes a severe limitation in works requiring a good measurement precision. Several alternative procedures, which overcome this limitation, have been studied. Two of the procedures yielded excellent results, with a coefficient of variation of 1 to 1.3%. One of them consist of two heating cycles at 300 0 C during 15 and three hours respectively, before irradiation, followed by a heating cycle at 100 0 C during 15 minutes, after irradiation. In a second procedure the material is heated at 300 0 C during three hours, pre-irradiation, followed by a heating cycle at 100 0 C. during 15 minutes, after irradiation. In all cases the heating cycle are followed by fast cooling periods. (author) [pt

  10. Development of CaSO4:Dy based ring dosemeter for extremity monitoring of radiation workers in India

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Meenal, P.; Bhagat, R.V.; Singh, R.; Kolambe, D.H.; Chougaonkar, M.P.; Sapra, B.K.

    2014-01-01

    Extremity dosemeters are required to be worn in cases where the dose to extremities is expected to be significantly greater than the dose to the whole body. In India, CaSO 4 :Dy based three element personnel monitoring TLD badge worn at chest and wrist level are used for whole body and extremity monitoring, respectively. Presently no official/legal finger dosemeter is available for extremity monitoring for radiation workers in the country. To cater to the long standing requirement of finger dosimeter, a new compact three-element Extremity Ring Badge Dosemeter (ERBD) has been developed for measurement of the equivalent doses received by the extremities of radiation workers in terms of operational quantity Hp(0.07). It was aimed to meet the performance requirement of IEC/ISO standards. This paper gives the design detail and result of experimental studies of ERB dosemeter

  11. Thermoluminescent characteristics of CaSO4:Dy+PTFE irradiated with high energy electron beams

    International Nuclear Information System (INIS)

    Alvarez, R.; Rivera, T.; Calderon, J. A.; Jimenez, Y.; Rodriguez, J.; Oviedo, O.; Azorin, J.

    2011-10-01

    In the present work thermoluminescent response of dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO 4 :Dy+PTFE) under high electron beam irradiations from linear accelerator for clinical applications was investigated. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator Varian, C linac 2300C/D, for clinical practice purpose. The electron irradiations were obtained by using the water solid in order to guarantee electronic equilibrium conditions. Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO 4 :Dy+PTFE were conducted under high electron beams irradiations. The thermoluminescent response of the pellets showed and intensity peak centered at around 235 C. Thermoluminescent response of CaSO 4 :Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO 4 :Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. (Author)

  12. Photo-TL in CaSO4:Dy: high exposure dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Mayhugh, M.R.

    1974-01-01

    CaSO 4 :Dy exposed to 10 3 to 10 8 R then annealed in the range 280 to 400 0 C displays little TL in the major dosimetry peak near 200 0 C. Subsequent illumination with 250 nm light reinduces the 200 0 C TL. This radiation-enabled photo-TL is roughly proportional to the square root of the enabling exposure at least to 10 8 R. (auth)

  13. Application of photo transferred thermoluminescence in the ophthalmologic area by using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio H.; Campos, Leticia L.; Schor, Paulo; Melo Junior, Luis A.S. de

    2002-01-01

    The utilization of CaSO 4 :Dy pellets to laser radiation detection on the ophthalmologic area is being studied by IPEN together with UNIFESP, in order to obtain an adequate dosimeter to set the dose laser spread and received by the patients, professional of health and environmental. The method of phototranferred thermoluminescence (PTTL) using CaSO 4 :Dy pellets with 0,8 mm of thickness, introduced good sensibility to the excimer laser used on UNIFESP. The PTTL signal to the laser radiation shown reproducible and linear in a great range of absorbed energy (∼ 4.000 mJ) and gamma doses (5-100 Gy) and, points of measure with distances source laser-sample in order of 4,0 m presents good resolution of the PTTL signal. A method of monitoring the area in the surgery room was tried between the IPEN and UNIFESP. Using the CaSO 4 :Dy, the researchers have had a method cheaper and accessible to study the eventual risks of the ultraviolet radiation on the chromosomic breakage and in the development of malignancies tumors in professional of health exposed daily to the excimer laser used in corneans refractive surgeries. (author)

  14. Development of sintered composites CaSO4 doped with Dy and Nd

    International Nuclear Information System (INIS)

    Chagas, M.A.P.; Parente, L.J.; Souza, D.N.

    2007-01-01

    The main of this work was the developing of sintered composites in order to use as thermoluminescent dosimeters using a simple route to preparation, employing high temperature. The composites were prepared with CaSO 4 .2H 2 O doped with Dy 2 O 3 and NdO 3 . Initially CaSO 4 .2H 2 O was dehydrated in oven at 100 deg C by 1h. After the addiction dopants and homogenization of compounds, PVA was incorporated to make easy to compaction of composites. The pellets with 6 mm of diameter and 1 mm thickness were sintered at 900 deg C and 1000 deg C by 6 h. The TL emission showed two peaks when the samples were irradiated with beta source (Sr 90 +Y 90 ). In all cases, the calibration curves presented responses proportional to absorbed dose. The results showed that this material have potential to be used in dosimetry. (author)

  15. Characteristics Of Dosimeter TL CaSO4:Dy Glass Capillaries For Environmental Radiation Dose Monitoring

    International Nuclear Information System (INIS)

    Sofyan Hasnel; Yulianti, Helfi; Ramain, Abubakar; Kusumawati, Dyah D.; Suyati

    2000-01-01

    research on the characteristic of dosimeter TL CaSO 4 : Dy glass capillaries for environmental dose radiation have been carried out. The results obtained are uniform response and reproducibility during three cycles consumption with average percentage standard deviation of 7.31 % and 5.45%. The response dose is linear and has a minimum detectable dose of 0.01 mGy, sunshine effect with non-penetrating light capsule of 4.65%, humidity effects is not significant by using non-penetrating light capsule. Radiation dose information during 30 days are fading 25%

  16. Thermoluminescent response of CaSO4: Dy + PTFE to beta particles

    International Nuclear Information System (INIS)

    Aguirre C, A.; Azorin N, J.

    2000-01-01

    In this work the results of studying the thermoluminescent properties of CaSO 4 : Dy + PTFE are presented when it is irradiated with beta particles. The conclusion was the obtention of the Tl response curve in function of dose is that to desexcite the dosemeters at temperature 300 C during 30 minutes and after that were irradiated at different times in groups and to do the reading of dosemeter, it can be observed that a greater irradiation time major is the Tl response and this depends of the material has been used. (Author)

  17. Fast neutron dosimetry using CaSO4:Dy thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorin, N.G.; Salvi, C.R.; Rubio, J.L.; Gutierrez, C.A.

    1980-01-01

    The use of CaSO 4 :Dy phosphor powder in fast neutron dose measurements using the activation of sulphur from the 32 S(n,p) 32 P reaction is described. The thermoluminescence induced during the irradiation and that due to the decay of short-lived activation products, is erased by annealing the dosimeters after a post-irradiation time of 3 days. The self-induced thermoluminescence measured at different intervals of post-irradiation time, gives an estimation of the fast neutron dose to which the dosimeters were exposed

  18. TL sensitivity of CaSO4:Dy phosphor powder - effect of grinding

    International Nuclear Information System (INIS)

    Shastry, S.S.; Kher, R.K.

    1979-01-01

    Grinding of polycrystalline CaSO 4 :Dy phosphor to powder form induces lattice defects. Changes in thermoluminescence (TL) sensitivity due to variation in trap density in the bulk and on the surface of phosphor grains are studied using gamma and UV radiations. TL sensitivity to gamma increases with grinding time due to the contribution from the new bulk traps which are generated by grinding. The surface traps degrade with increase in grinding time resulting in a decrease in UV sensitivity. Results on regeneration of the TL sensitivity due to annealing at different temperatures are also included. (Auth.)

  19. Effect of temperature during UV and gamma irradiations of TL phosphor CaSO4:Dy

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Pendurkar, H.K.

    1979-01-01

    Temperature is an important parameter in thermoluminescence studies. Irradiation at enhanced temperatures reduces the γ response of TL phosphor CaSO 4 :Dy. However, in the presence of fluorescent lights, the γ response of the phosphor is enhanced by approximately 20% for temperatures around 60-100 0 C. If the phosphor temperature during UV exposure is kept high, the integrated TL output continues to increase until it reaches 18 times at 160 0 C as compared to that produced by UV exposure at room temperature. (Auth.)

  20. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  1. Investigation of beta ray attenuation in CaSO4:Dy(Tm)-teflon rods

    International Nuclear Information System (INIS)

    Szabo, P.P.

    1990-12-01

    Ultrathin discs were prepared from CaSO 4 :Dy(Tm)-teflon rods by cutting them with a microtom. The effect of cutting was studied experimentally. It was found that the cutting does not affect the TL signal of the discs, so one will be able to irradiate the rod and cut it afterwards which means that this method can be applied in the dosimetry of boundaries or to establish the energy of beta radiation. Depth dose distribution measurements were carried out by irradiating the rods with beta sources. (K.A.) 5 refs.; 6 figs

  2. Improvement in the dosimetric CaSO4: Dy obtention method

    International Nuclear Information System (INIS)

    Campos, L.L.; Frutuoso, P.H.; Souto, V.J.

    1989-08-01

    With the purpose of saving up in the dosimetric CaSO 4 : Dy production, a new method was developed to obtain single crystals. In this method the nitrogen flux used to carry the acid vapour was substituted by compressed air. It was compared all dosimetric properties of the crystals. There is no alteration in the glow curve. The sensitivity is the same in both cases and the lower detection limit is 3.8 x 10 -8 C.Kg -1 (150 μR) [pt

  3. CaSO4:Dy and/or Tm: study of its properties for dosimetry application

    International Nuclear Information System (INIS)

    Ferreira, M.M.

    1979-01-01

    In order obtain in practical and cheap solid state dosimeter with high sensitivity, a technique initially developed to cold press a mixture of suitable materials in their powder form sensitive to radiation. The material initially used was natural CaF 2 (fluorite) for this salt was extensively studied in radiation dosimetry since it shows a thermoluminescent (TL) effect after radiation. However, natural calcium fluorite shows two main disadvantages: its high senstivity to room light and the impossibility to control its impurity content due to its natural origin. Calcium sulphate was thus used as a good substitute of fluorite. Rare earths doped calcium sulphate shows a high TL sensitivity and is not disturbed by light. It is also easily obtained in the laboratory under controlled conditions so to get reproducible impurity content. The best dosimeters that can be produced with rare earth doped calcium sulphate are CaSO 4 :Dy and CaSO 4 :Tm. Calcium sulphate, simultaneously doped with Tm and Dy was produced and 100% increase was obtained in the TL sensitivity when compared with the individually are earth doped calcium sulphate. (Author) [pt

  4. Preparation and structural characterization of the thermoluminescent material CaSO4: Dy

    International Nuclear Information System (INIS)

    Sanchez R, A.; Azorin, J.; Gonzalez M, P.R.; Rivera, T.

    2005-01-01

    The grade of crystallinity of a material is important so that the one is presented the thermoluminescence phenomenon; for what is necessary to study those structural characteristic of a TL material and to correlate them with its TL response when being irradiated with ionizing radiation. The calcium sulfate activated with Dysprosium (CaSO 4 : Dy) it is a material that has demonstrated its efficiency in the dosimetry of the ionizing radiation for the thermoluminescence method. In this work the structural characterization of this prepared material for the recrystallization method by means of the evaporation of the solvent and their relationship with their TL response is presented. The results showed that the best material to be used in thermoluminescent dosimetry presents a crystalline structure in orthorhombic phase and a particle size in the interval of 80 μm to 200 μm. (Author)

  5. Dosimetric characteristics and radiation monitoring with CaSO4(Dy):NaCl pellets

    International Nuclear Information System (INIS)

    Kathuria, S.P.; Campos, L.L.; Gordon, A.M.P.L.

    1981-06-01

    CaSO 4 (Dy):NaCl Tl dosimeters, in the form of pellets, are used in the field for a period of one month. Before using these pellets for environmental and personnel radiation monitoring some of the important dosimetric characteristics like fading reusability and effect of ambient light are investigated and described. The pellets are used with plastic and lead filters for personnel and environmental radiation monitoring and the results obtained with the lead filters are in good agreement with those of the energy independent LiF dosimeters. A new combination of plastic, aluminium and lead filters is suggested for dose measurements in a mixed field of X, gamma and beta radiations. (Author) [pt

  6. Effect of the temperature in the sensitivity of CaSO4: Dy

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Alcantara, B.C.; Azorin, J.; Furetta, C.

    2003-01-01

    Sensitivity of a Tl material is one of the most important properties for dosimetry. This property is optimized by means of various processes such as the incorporation of different dopants into the matrix material, the application of certain doses of ionizing radiation and carefully controlled thermal treatments among others. Results obtained of studying the sensitivity of diverse preparations of CaSO 4 : Dy submitted different thermal treatments are presented. The material, which presented the highest sensitivity, was that one it was heated to 800 C during one hour. When the temperature was raised over this value it was observed that sensitivity drops again. In other hand, as the heating rate in lowing down, during the readout, the height of the glow curve decreases proportionally. The temperature of the maximum of the main peak also decreases. (Author)

  7. Optimization of the obtaining method of CaSO4: Dy + Ptfe dosimeters

    International Nuclear Information System (INIS)

    Galicia A, J.; Rioja Ch, J.; Torijano C, E.; Azorin N, J.

    2012-10-01

    This work contain the obtained results of studying the response when irradiating to different dose of X-rays, dosimeters of CaSO 4 : Dy + Ptfe using different lapses of time in their preparation (a lot of selected dosimeters of an elaboration process of 3 days and another of an elaboration process of 2 hours). For the elaboration of the powdered material, the evaporation method was used; the irradiation were carried out in a lineal accelerator Elekta Synergy property of the National Medical Center, 20 de November. The similarities and differences are shown among the two dosimeters lots together with an analysis of the shine curves and of calibration selecting those that presented a better behaviour and a more rea liable response. (Author)

  8. Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays

    International Nuclear Information System (INIS)

    Chang, J.-K.; Nam, Y.-M.; Kim, J.-L.; Chang, S.-Y.; Kim, B.-H.

    2001-01-01

    The energy dependence of a CaSO 4 :Dy TL phosphor for 21 monoenergetic photons of energy ranging from 0.01 to 3 MeV was calculated by using MCNP4A code. The calculation results show good agreement with those of other authors within ± 5% relative error. Calculations and experiments are also performed to determine the energy dependence of CaSO 4 : Dy phosphor with Dy concentrations from 0.01 to 1.5 mol %, and with the compositions of TL-Teflon from 10 to 90 wt %. The calculated energy responses show good agreement with the experiment results within ± 20% relative error except for a concentration lower than 0.1 mol % Dy and the low energy regions of M30 (Eave.=20 keV) and M60 (Eave.=34 keV). For the TL-Teflon mixture, the energy dependence shows an decreasing trend with the increase of Teflon concentration in MCNP calculation but shows no dependence for TL-Teflon mixture proportions in experiment. These differences are due to the non-homogeneous distribution of Dy concentration and the effect of large grain size in the phosphors. The energy dependence of the 30 wt/o CaSO 4 (0.1 mol%;Dy) and 70 wt/o Teflon that is placed behind the filters of plastic, aluminum, copper, tin and lead with a thickness from 0.1 to 2 mm were calculated, respectively

  9. The role of annealing: effect on CaSO4:Dy phosphor with manganese and sodium impurities

    International Nuclear Information System (INIS)

    Li, S.-H.; Hsu, P.-C.

    1990-01-01

    The effect of the annealing treatment on the CaSO 4 :Dy phosphor with Mn and Na impurities was studied at different annealing temperatures from 100 0 C to 800 0 C. Doping with or without impurity caused no difference in the properties for temperatures less than 400 0 C. An annealing temperature greater than 400 0 C brings a reduction in low temperature peak intensities of CaSO 4 :Dy with Na only. The high temperature peak intensities increase as the temperature increases from 400 0 C to 600 0 C. However, annealing at a temperature greater than 600 0 C brings a drastic reduction in high temperature peak intensities as well as TL output. (author)

  10. Thermal neutrons thermoluminescence dosimetry using CaF2 + KBr e CaSO4: Dy + Br

    International Nuclear Information System (INIS)

    Leite, A.M.P.

    1979-01-01

    Cold-pressed samples of CaF 2 + KBr and CaSO 4 :Dy + KBr have been used in the thermal neutron detection by the thermoluminescence technique. The amount of 100 mg of the TL phosphor added to 80 mg of KBr showed to be the optimum mixture regarding sensitivity as well as the handling of the dosimeters. The detection is based on the self-irradiation of the phosphor by the Br isotopes activated by exposure to a neutron-gama field. The prompt dose and consequentely the gama contribution are erased by post-irradiation thermal annealing. A linear dependence has been found between the TL self-induced signal and the thermal neutron flux in the range 10 6 n.cm -2 .seg -1 -10 -12 n.cm -2 .seg -1 . The minimum detectable fluence has benn determined as 10 9 n.cm -2 and 10 6 n.cm -2 using pellets of CaF 2 + KBr and CaSO 4 :Dy + KBr, respectively. The main results suggest the use of CaSO 4 :Dy + KBr pellets and TL as a complementary technique for thermal neutron detection. (author) [pt

  11. Simultaneos determination of absorbed doses due to beta and gamma radiations with CaSO4: Dy produced at Ipen

    International Nuclear Information System (INIS)

    Campos, L.L.; Rosa, L.A.R. da.

    1988-07-01

    Due to the Goiania radiological accident, it was necessary to develop urgently a dosimeter in order to evaluate, simultaneously, beta and gamma absorbed doses, due to 137 Cs radiations. Therefore, the Dosimetric Material Production Laboratory of IPEN developed a simple, practical, light and low cost badge using small thickness (0,20mm) thermoluminescent CaSO 4 : Dy pellets produced by the same laboratory. This pellets are adequate for beta radiation detection. These dosimeters were worn by some IPEN technicians who worked in Goiania city, and were used to evaluate the external and internal contaminations presented by the accident victims interned at the Hospital Naval Marcilio Dias. (author) [pt

  12. Measurement of the dose by dispersed radiation in a lineal accelerator using thermoluminescent dosimeters of CaSO4:Dy

    International Nuclear Information System (INIS)

    Chavez C, N.; Torijano, E.; Azorin, J.; Herrera, A.

    2014-08-01

    The thermoluminescence (Tl) is based on the principle of the luminescent in a material when is heated below their incandescence temperature. Is a technique very used in dosimetry that is based on the property that have most of the crystalline materials regarding the storage of the energy that they absorb when are exposed to the ionizing radiations. When this material has been irradiated previously, the radioactive energy that contains is liberated in form of light. In general, the principles that govern the thermoluminescence are in essence the same of those responsible for all the luminescent processes and, this way, the thermoluminescence is one of the processes that are part of the luminescence phenomenon. For this work, the dispersed radiation was measured in the therapy area of the lineal accelerator of medical use type Elekta, using thermoluminescent dosimeters of CaSO 4 :Dy + Ptfe developed and elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa. With the dosimeters already characterized and calibrated, we proceeded to measure the dispersed radiation being a patient in treatment. The results showed values for the dispersed radiation the order of a third of the dose received by the patient on the treatment table at 30 cm of the direct beam and the order of a hundredth in the control area (4 m of the direct beam, approximately). The conclusion is that the thermoluminescent dosimeters of CaSO 4 : Dy + Ptfe are appropriate to measure dispersed radiation dose in radiotherapy. (author)

  13. Evaluation of the substitution of PMMA plates by PLA 3D printed in TL response of CaSO_4:Dy

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de; Valeriano, Caio Cesar Santos; Campos, Leticia Lucente

    2016-01-01

    The CaSO_4:Dy is a dosimetric material that is nationally produced, which presents high sensibility but a high energy dependence of its thermoluminescent (TL) response at the photoelectric effect region. This study aims to compare the TL response of the CaSO_4:Dy when irradiated, with different energies, at the presence of 3D printed plates of polylactic acid (PLA) and polymethylmethacrylate (PMMA). Results show that the PLA has a different attenuation of the radiation, when compared to PMMA, indicating that it should be taken into account the quality of the print used on PLA plates manufacture. (author)

  14. Development of thin dosemeters of CaSO4: Dy for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.

    1987-01-01

    Thin pellets of CaSO: Dy (0,20mm) were produced and tested in beta radiation fields. The Thermolumiscent (TL) characteristics studied were sensitivity, reproducibility, lower detection limit, linearity of TL response with absorved dose energy dependence. The results show the usefulness of this thin pellets in beta radiation detection. (Author) [pt

  15. Optimizing a method to obtain CaSO4 activated with Dy for use in thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Gonzalez M, G.

    1981-01-01

    Results obtained from experiments in optimizing the variables in the preparation of CaSO 4 activated with dysprosium, as phosphors to be used as low dose TL dosemeters for routine radiological protection are presented. The technique used combined those of T. Yamashita and of K. Becker. Heating 8.6 gm of CaSO 4 .H 2 O with 0.1 mol % of Dy 2 O 3 in 115 ml of concentrated H 2 SO 4 to 285 0 C to completely evaporate the acid and placing the obtained crystals in a 600 0 C oven for one hour gave a TL dosimeter with a sensitivity sufficient to measure 5 mR of 60 Co gamma radiation and show a lineal response with this radiation in a 5 mR-5x10 4 R interval. Fading, which appeared in the phosphor only after three weeks, was in the fourth week 4.0% and in the eighth week 6.2% with a σ=+-2.1%. The quality of the phosphor obtained and its ease of reproducibility deserves note. (author)

  16. Measurement of absorbed dose for high energy electron using CaSO4: Tm-PTFE TLD

    International Nuclear Information System (INIS)

    Park, Myeong Hwan; Kim, Do Sung

    2000-01-01

    In this study, the highly sensitive CaSO 4 : Tm-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. CaSO 4 : Tm phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5mm, thickness 90mg/cm 2 ) by cold pressing. The absorbed dose distribution and ranges for high energy electron were measured by using the CaSO 4 : Tm-PTFE TLDs. The ranges determined were R 100 =3D14.5mm, R 50 =3D24.1mm and R p =3D31.8mm, respectively and the beam flatness, the variation of relative dose in 80% of the field size, was 4.5%. The fabricated CaSO 4 : Tm-PTFE TLDs may be utilized in radiation dosimetry for personal, absorbed dose and environmental monitoring.=20

  17. Development and evaluation of a new baDge/filter for thermoluminescent monitoring with CaSO4: Dy/PTFE

    International Nuclear Information System (INIS)

    Campos, Vicente de Paula

    2005-01-01

    Calcium Sulfate (CaSO 4 :Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by the Instituto de Pesquisas Energeticas e Nucleares (IPEN), SP, Brazil since 70's and 80's, due to important work of its researchers and collaborators. This phosphor advantages, beside the fact that it is produced by IPEN itself, begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. This phosphors was used primarily in environmental and area monitoring at IPEN facilities and in a few external institutions, once it presents more sensibility than other phosphors, like LiF:Mg. Its mainly disadvantage is a strong energetic dependence response to ionizing radiation, which must be corrected for its application in every radiation field. This phosphor has been used inside a badge which is an adaptation from photographic film badges used in the past. This badge permits a reasonable correction in the energetic dependence, only for orthogonal beam incidence. With the objective of improve the performance and reduce the energetic dependence on any incidence angle, reducing the dose measurement uncertainty too, this work presents a study on a new badge, with a new filter geometry, and its performance was compared to the actual dosimeter in use, with significant improve on results. Gamma irradiations of 60 Co and x-rays of 25,1; 33; 37,3 and 82,1 keV, on incidence angles of 0 deg, 30 deg, 45 deg and 90 deg were done at facility conditions of IPEN. Semi-empirical computational simulation using finite differences in three dimensions were done. The results pointed out the best filter thickness and width for initiate the prototype production, in order to optimize the correction on energetic dependence on irradiation of photons of 33, 48, 118 and 1250 keV energies under many incidence angles. (author)

  18. Characterization and standardization of a thermoluminescent dosimetric system to ultraviolet and laser radiation using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio Henrique

    2002-01-01

    The photo transferred thermoluminescence (PTTL) was used to characterize a dosimetric system to the laser and ultraviolet radiation. Dysprosium activated calcium sulphate samples (CaSO 4 :Dy) used are produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN) and have proved been an excellent dosimetric material for non ionizing radiation. PTTL signal was studied for UV radiation detection in the 220 to 450 nm range and for laser radiation in the 193 to 1.160 nm range. The samples presented more sensibility to the 193, 250, 310 and 337 nm wavelengths and no sensibility to infrared region. The samples presented linear PTTL in function of radiant exposure, excitation gamma dose in the range between 5 and 100 Gy and laser beam diameter between 2 and 6 nm. Another parameters studied were the angular dependence, UV lower exposure limit and PTTL signal optical fading. Spread laser radiation analysis was performed in the Ophthalmologic Department of Universidade Federal de Sao Paulo (UNIFESP) surgical center, showing that samples positioned as far as 4 m from laser source are sensitized to the laser radiation, as well as evaluating the laser exposure received by workers of medical area. A method to send the samples by mail was developed to the studies performed in the UNIFESP. (author)

  19. Determination of exposure rates from natural background radiation in Khartoum using LiF:Mg,Cu,P (GR-200) and CaSo4: Mn TLD chips

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khangi, F.A.; Shaddad, I.A.; Suliman, I.A.; El Amin, O.I.

    2002-01-01

    The exposure rates from natural background radiation - including terrestrial gamma radiation and the ionizing component of cosmic rays - were measured for the first time in the city of khartoum using two types of TLD materials: LiF:Mg,Cu,P (GR-200) and CaSo 4 :Mn TLD chips. Measurements were performed at two sites simultaneously, one site was selected on land in the vicinity of the Sudan Atomic Energy Commission, for the purposes of the measurement of the total exposure rate outdoors, while the other site was located on a buoy anchored in the Blue Nile, and was selected to measure the exposure rate due to the ionizing component of cosmic rays. The investigations were conducted for periods of between 5 and 28 days. Calibration was performed on a selected number of dosimeters to determine the exposure rates at each site. The exposure rates from the ionizing component of cosmic rays in Khartoum were found to be respectively 33 nGy.h -1 and 30 nGy.h -1 , in the measurements performed within the scope of this work using GR-200 and CaSo 4 :Mn dosimeters, while the total values for exposure on land were found to be 45 nGy.h -1 and 42 nGy.h -1 respectively. These values compare reasonably well with other national averages reported in the UNSCEAR publication. The comparison of the results for the two dosimetric materials demonstrates both the sensitivity and suitability of GR-200 for the purposes of environmental monitoring (orig.)

  20. A primary assessment of a daybreak 2200 OSL reader using fine grain quartz and CaSO4:Tm TLD

    International Nuclear Information System (INIS)

    Zhang Keqi; Chen Jie; Lu Yanchou; Wang Changsheng; Yang Chuancheng

    2007-01-01

    Daybreak 2200 OSL readers are widely used for luminescence dating applications. As the sample irradiation and illumination may affect discs in adjacent positions, it is critical to confirm that these factors do not introduce significant systematic errors. Effects of cross-irradiation and cross-bleaching were examined and quantified using fine-grain quartz and highly sensitive CaSO 4 :Tm dosimeters, and the irradiation offset time was measured. The cross-bleaching effect on adjacent aliquots is non-linear with no more than 15% OSL signal reduction following 10ks illumination with the power of blue LED being at 95% maximum. But at positions other than the nearest neighboring sample, almost no effect of cross-bleaching was found. The cross-talk dose, even to the nearest samples, was about 0.02% of the applied dose, and it decreased with increasing distance from the source. Offset time of the built-in Beta source shutter is 0.22 s, which can be neglected in regular dating, and leak dose of the source can be ignored as well. Finally, measurement consistency at Position 0.5, 10, ..... and 55 of the sample tray is better than 3% in relative standard deviation. (authors)

  1. Self-dose and fading of CaSO4(Dy/Tm) and CaF2 (natural) TL phosphors in environmental radiation monitoring

    International Nuclear Information System (INIS)

    Nambi, K.S.V.

    1982-01-01

    A 'shielded storage experiment' for estimating both the 'self-dose' and 'fading' of TL phosphors under conditions akin to those faced in environmental monitoring applications is described. Using this method, self-dose rates of 0.32 +- 0.10(sigma) μ rad h -1 and 1.16 +- 0.02(sigma) μ rad h -1 have been obtained for CaF 2 (natural) and CaSO 4 (Dy) phosphors; the thermal decay constants at 25 0 C for these phosphors turn out to be 27 X 10 -6 h -6 ad 12 X 10 -6 h -1 , respectively. Estimation of the self-doses from radioactivity measurements of the phosphors concerned is also presented and the differences explained. A very high self-dose rate of 5.6 μ rad h -1 was estimated by the latter method for a sample of CaSO 4 (Tm) phosphor. (orig.)

  2. The effect of ultraviolet and visible radiation on the readout obtained from γ-irradiated and unirradiated CaSO4:Dy in teflon discs

    International Nuclear Information System (INIS)

    Bartnik, D.L.; Calvert, R.L.; Young, J.G.

    1982-07-01

    The effect of ultraviolet and visible radiation on the readout obtained from the main dosimetry peak of CaSO 4 :Dy in teflon discs is explained by the net result of three separate factors, namely (i) an inherent response, (ii) a phototransfer and (iii) an optical bleaching. Their dependence on wavelength, irradiance and radiant exposure has been studied using a fluorescent light enclosed in a perspex diffuser and a 200W mercury-xenon lamp in conjunction with narrow bandpass filters to isolate specific wavelengths

  3. Assessment of CaSO4:Dy and LiF:Mg,Ti thermoluminescent dosimeters performance in the dosimetry of clinical electron beams

    International Nuclear Information System (INIS)

    Nunes, Maira Goes

    2008-01-01

    The assessment of the performance of CaS0 4 :Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaS0 4 :Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage. (author)

  4. Study of the OSL response of the CaF2:Dy (TLD-200) dosimeter

    International Nuclear Information System (INIS)

    Medeiros, Beatriz M.; Alencar, Marcus A.V. de

    2013-01-01

    The OSL dosimetry has become, in recent years, a successful technique in personal and environmental dosimetry due to high luminescence efficiency, excellent reproducibility, fast readout of signal and repeated and successive OSL measurements of the same dosimeter. Another factor that contributes to the increased use of OSL dosimetry is the use of the aluminum oxide doped with carbon (Al 2 O 3 :C) as dosimeter. Developed initially as thermoluminescent dosimeter, the Al 2 O 3 :C has an excellent OSL sensitivity, high efficiency, good linearity, low or no fading and excellent stability with respect to environmental conditions. However, the OSL dose response for aluminum oxide is linear only for low doses. For intermediate doses (doses in radiotherapy), the response is supralinear. For the values of high doses used in the processes of food irradiation and sterilization of surgical materials, the OSL signal of the aluminum oxide already saturated. Furthermore, the degree of supralinearity and the saturation value vary from sample to sample (∼ 30-300 Gy). Therefore, the use of aluminum oxide as OSL dosimeter is inappropriate in radiotherapy and in the irradiation industrial processes. The objective of this work is the study of the OSL properties of other dosimetric materials irradiated with values of intermediate and high dose to verify the applicability of the OSL dosimetry in radiotherapy and in the processes of food irradiation and sterilization of medical materials. The dosimetric material used in this work is the calcium fluoride doped with dysprosium (CaF 2 :Dy) produced by Harshaw and known commercially as TLD-200. The results demonstrate that the CaF 2 :Dy has OSL signal and the OSL dose response is linear in the range of 10 Gy to 300 Gy. Therefore, the dosimetry OSL with this dosimeter can be used in the evaluation of doses of the order of dozens to hundreds of grays. (author)

  5. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  6. Analysis of glow curves of TL readouts of CaSO4:Dy teflon based TLD badge in semiautomatic TLD badge reader

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Sneha, C.; Adtani, M.M.

    2010-01-01

    The facility of glow curve storage and recall provided in the reader software is helpful for manual screening of the glow curves; however no further analysis is possible due to absence of numerical TL data at the sampling intervals. In the present study glow curves are digitized by modifying the reader software and then normalized to make them independent of the dose. The normalized glow curves are then analyzed by dividing them into five equal parts on time scale. This method of analysis is used to correlate the variation of total TL counts of the three discs with time elapsed post irradiation

  7. Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms

    International Nuclear Information System (INIS)

    Bravim, A.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The performance of CaSO 4 :Dy and LiF:Mg,Ti dosimeters to electron beams applied to radiotherapy was investigated. The TL response of these dosimeters was studied for 6 MeV electron beams using PMMA and Solid Water (SW) phantoms. The dosimeters were previously separated in groups according to their TL individual sensitivities to 60 Co gamma-radiation in air under electronic equilibrium conditions. After that, they were irradiated with 6 MeV electron doses of 0.1, 0.5, 1, 5 and 10 Gy using a linear accelerator Clinac 2100C Varian of Hospital Israelita Albert Einstein – HIAE. The electron beam irradiations were performed using a 10 × 10 cm 2 field size, 100 cm source-phantom surface distance and the dosimeters were positioned at the depth of maximum dose (1.2 cm). The TL readings were carried out between 24 and 32 h after irradiation using a Harshaw 3500 TL reader. The TL dose–response of both type of dosimeters and phantoms presented linear behavior on the electron dose range from 0.1 to 5 Gy CaSO 4 :Dy dosimeter is 21 times more sensitive than LiF:Mg,Ti, dosimeter commonly used in clinical dosimetry. The obtained results indicate that the performance of CaSO 4 :Dy dosimeters is similar to LiF:Mg,Ti dosimeters and this material can be an alternative dosimetric material to be used to clinical electron beams dosimetry.

  8. Application of thermoluminescent dosimeters (CaSO4:Dy) in the evaluation of the dose in ornamental granites of Pernambuco, Brazil

    International Nuclear Information System (INIS)

    Rocha, Edilson Accioly; Cardoso, Jorge J.R.F.; Santos Junior, Jose A. dos; Silva, Cleomacio M. da

    2007-01-01

    The granites of Pernambuco are being used as ornamental rocks, and besides being commercialized in our state. They are also exported to Europe and Asia. The granite is utilized in the fabrication of objects and in wall and floor covering. It is scientifically known because it presents natural series of radionuclides ( 238 U and 232 Th) and 40 K which are higher than the average content of the other rocks. The gamma radiation of the granite coming from the decay of the series cited accompanied by 40 K, must not exceed the limit of 1 mSv.a -1 for the public, according to norms that are in effect. The objective of this work is to evaluate the dose of gamma radiation that is absorbed by individuals who are exposed to the granite. This work is expected to contribute to environmental monitoring and to the evaluation of health risk to man. Pieces of granite from diverse environments were monitored for a total period of 225 days. Three batches of CaSO 4 :Dy were used. The first batch remained fixed to the pieces of granite (one dosimeter for each object) for period of sixty-eight days. After the reading, they were reaffixed to the same objects, each one of them accompanied by one or more dosimeters from the second and third batches. The dosimeters remained affixed for another average period of one hundred and forty-eight days. The absorbed doses found varied from the background up to 0.64 mSv.a -1 , with a general average of 0.24 mSv.a -1 , thus, it was concluded that the doses of granite studied, up to the present, were inside the parameters recommended by CNEN, when considering potentially exposed members of the public. (author)

  9. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  10. Measurement of thermal neutron fluence with CaSO4 thermoluminescent phosphors

    International Nuclear Information System (INIS)

    Liu Jinhua; Su Jingling; Wei Zemin

    1984-01-01

    During neutron irradiation, some TL phosphors were activated. After leaving the irradiation field the TL phosphor produced self-irradiation. The TL output of self-dose was only related to the original neutron fluence and independent of the γ-radiation. Several CaSO 4 TL phosphors were made. They were CaSO 4 :Dy, CaSO 4 :Dy-Teflon, CaSO 4 :Dy mixed with Dy 2 O 3 , CaSO 4 :Mn mixed with Dy 2 O 3 . The linearity, and lower detection limits of these TL phosphors were measured. The thermal neutron response of CaSO 4 :Mn mixed with Dy 2 O 3 was 64 R/(10 10 cm -2 ) and the lower detection limit was 1.3x10 5 cm -2

  11. Difficulty in estimation of dose for the abnormal patterns of the TLD disc readings - need investigation and improvement in work practices

    International Nuclear Information System (INIS)

    Madhumita, B.; Ande, C.D.; Sneha, C.; Bakshi, A.K.; Datta, D.

    2018-01-01

    TLD badge based on CaSO 4 :Dy detector used for external radiation monitoring of occupational workers of radiation facilities in India plays a vital role in radiation protection program. Energy and type of radiation in the work-field can be well identified from the dose evaluation algorithm. Algorithm developed earlier use the set of disc ratio from the three disc readings of the TLD badge to arrive at the dose and the type of radiation. Algorithm fails to estimate the dose for the abnormal patterns. The paper discusses the root cause of the abnormal patterns and investigation followed to arrive the estimation of dose

  12. Pattern check of TLD disc readings - an important tool to identify abnormal conditions in workplace

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Sneha, C.; Bhattacharya, M.; Sahai, M.K.; Pradeep, Ratna; Datta, D.; Bhatnagar, Amit

    2016-01-01

    Personnel monitoring for external radiation using CaSO 4 :Dy based TLD badge is well established in Indian radiation protection program. TLD badge enables evaluation of occupational dose based on the pattern and values of the three disc readings. Different patterns of disc readings are obtained depending on the type and energy of radiation in the workplace. Pattern not conforming to the radiation in the workplace also called as improper pattern can be a useful tool for investigation of any deviation / abnormality in workplace or monitoring practices. The paper presents different examples of improper pattern observed in monitoring that has helped to find out the deviations in the workplace or monitoring practices. Results of the experiments conducted to simulate some of the observed pattern are also presented in the paper

  13. Adequacy of annealing duration in reducing the background counts of personnel monitoring TLD cards - a study

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Varadharajan, Geetha; Punekar, M.P.; Chougaokar, M.P.; Ayappan, P.

    2010-01-01

    In India, the personnel monitoring service of ∼ 70,000 radiation workers is being provided using indigenously developed TLD system comprising three CaSO 4 :Dy embedded Teflon discs. In order to remove TL and reset the distribution of defects/trapping centres, all TLD cards are subjected to an annealing treatment at elevated temperature prior to their next use. As per the standardized protocol annealing is carried out in a hot air circulating oven at 230 deg C for 4 hr, which is sufficient to reset the TL dosemeters for dose levels upto 100 mSv. In order to verify the appropriateness of annealing procedures adopted by the Laboratory, a detailed study was conducted using four sets of cards namely A, B, C and D series, exposed to various dose levels

  14. TLD personnel monitoring dose estimation- extending the upper limit of the dose range

    International Nuclear Information System (INIS)

    Popli, K.L.; Sathian, Deepa; Divakaran, T.; Massand, O.P.

    2001-01-01

    TLD personnel monitoring was introduced in the year 1975 in India and at present nearly 41,000 radiation workers are being monitored by 13 monitoring laboratories all over India. The BARC- TLD being used for personnel monitoring is based on CaSO 4 :Dy embedded in PTFE and semi-automatic TL reader using hot N 2 Gas for heating the dosimeters. This reader has the range to measure γ dose from ten μSv to 3 μSv and x-ray dose form 1 μ Sv to 0.3 Sv due to the higher sensitivity of CaSO 4 : Dy to lower energy photons (20keV-50 keV) generated by diagnostic x-ray units. The x-ray radiation workers are at present nearly 35% of the total radiation workers monitored and this number is expected to grow as more and more number of x-ray workers are covered under this service. The upper limit of the x-ray dose range of the instrument is 0.3 Sv, whereas in the past one year it has been observed that at least 25% of the total overexposures reported in case of x-ray workers have recorded the dose more than 0.3 Sv. This paper presents the technique developed to extend the upper limit of the range from 0.3 Sv to 1 Sv for x-rays and 10 Sv for γ rays

  15. Analysis of personnel monitoring results of external radiation doses received by occupationally exposed workers obtained using CaSO4: Dy TLD personnel monitoring badges at RAPS (2000-2004)

    International Nuclear Information System (INIS)

    Chourasiya, G.; Kher, R.K.; Rao, B.S.; Pradhan, S.M.

    2006-01-01

    Personnel monitoring is a key step in radiation protection programme. It helps in keeping a check on radiation hazards and safety aspects of the operating unit. Moreover, analysis of the temporal trends in exposure histories of the individuals/groups play an important role in assessing the need of improved standards of protection and the impact of implementation of such measures. The paper presents the analysis of annual effective dose and collective dose to the radiation workers, which are indicators of individual risk and the impact of the practice. The present study also gives the analysis of the effective dose, cumulative dose and various dose distribution ratios (SR E and NR E ) for the block of 5 years (2000-2004) of RAPS 1 and 2 the oldest PHWR in the country and RAPS 3 and 4 the latest in the series incorporating many improvements in design and operation. It is seen that occupational exposures at NPPs have been showing a steadily decreasing trend, which is a result of a number of design improvements, operation and protection measures. However, to achieve world standards, we have to go a long way by further carrying out identification of areas of improvement, good operating practices along with the desired modifications in design. (author)

  16. Assessment of dose using TLD during activity handling at RPhL, BRIT

    International Nuclear Information System (INIS)

    Choughule, Nitin V.; Bairwa, S.M.; Murali, S.; Rakesh, R.B.; Madhumita, B.; Adtani, M.M.; Mehra, Kiran; Padmanabhan, D.; Borkute, S.D.; Pal, N.; Sachdev, S.S.

    2012-01-01

    Radiopharmaceutical Lab (RPhL), BRIT undertakes production, supply of radiopharmaceuticals. At RPhL short lived isotopes 131 I, 99 Mo, 99m Tc, 125 I, 153 Sm, 32 P and 51 Cr, are handled with total activity handled per week ranging from MBq to TBq (mCiCi). Radiological survey provides idea on radiation level helps to ensure safe working condition. In order to improve the working condition and to estimate the integrated dose over a period of week with uniform pattern of activity handling in the period, a study was carried out using TLD badges. Specifically prepared TLD badges containing CaSO 4 :Dy phosphor were placed at various locations at RPhL It is used for personnel monitoring. One set of TLD was exposed for a week long period while the other set was exposed only during activity handling, kept in the lead pot during the rest of the period. Dose measured by TLDs were compared with the dose estimated using the survey data for the respective locations as well as with the dose estimated using the activity handled by taking into account the time, distance and shielding. The maximum radiation level recorded during lab survey was used to estimate the TLD exposure during the period. It was observed that results on TLD dose measurement and estimated doses using survey results were of same order. The cumulative TLD dose recorded for week duration (168 h) was significantly higher than doses recorded by exposed TLD only during activity handling (8 h). It was expected that the TLD dose would not be more than dose estimated using radiation survey data, while in 3 among 8 experimental TLDs, the dose was ∼ 25% higher. This could be due to the movement of active material or open handling of activity do not get reflected during normal radiation survey and contribution from background radiation at the lab where those TLDs were placed. The individual dose of all the personnel working in different labs were well within the relevant dose limits indicating the safe working condition

  17. Evaluation of the thermoluminescent detector answers of CaSO4:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator

    International Nuclear Information System (INIS)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L.

    2011-01-01

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO 4 :Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  18. Fading of CaSO4 thermoluminescent detectors after exposure to charged particles

    Czech Academy of Sciences Publication Activity Database

    Pachnerová Brabcová, Kateřina; Štěpán, Václav; Kubančák, Ján; Davídková, Marie; Ambrožová, Iva

    2017-01-01

    Roč. 106, č. 12 (2017), s. 569-572 ISSN 1350-4487 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : thermoluminescent detectors * CaSO4:Dy * fading * charged particles Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.442, year: 2016

  19. Environmental monitoring with a portable TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P P; Feher, I; Deme, S; Szabo, B; Vagvoelgyi, J; German, E [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    Two types of TLD systems are used for environmental dose monitoring. One is based on an NHZ-203 laboratory TLD reader and CaSO/sub 4/:Dy powder. The other is based on CaSO/sub 4/:Tm bulbs and a small, portable TLD reader built into a cross-country car and operated by means of the car battery. The laboratory TLD system has been used for many years for environmental monitoring and it has been tested and proved satisfactory at international intercomparisons for environmental dosemeters. The new portable TLD system has the advantage of being able to establish the dose in a few minutes at the environmental station. The transport dose is omitted as the TLDs are evaluated at the field site. The evaluation of a bulb needs only a few minutes and the measured dose value can be reported back by radio - an important aspect during an emergency situation.

  20. Measurement of annual dose on porcelain using surface TLD method

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2001-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of measurement of annual dose using ultrathin (CaSO 4 :Tm) dosage layer on porcelain was studied. The TLD was placed on the part of porcelain without glaze. A comparison of measurement of annual dose for surface TLD, inside TLD and alpha counting on porcelain was made. The results show that this technique is suitable for measuring annual dose and improving accuracy of TL authentication test for both porcelain and pottery

  1. Comparison of the TL intensity of the sintered composites of CaSO4+Tm

    International Nuclear Information System (INIS)

    Junot, O.D.; Sousa, F.L. de; Chagas, M.A.P.; Souza, D.N.

    2009-01-01

    The objective of this work is to compare the thermoluminescent intensity (TL) of CaSO 4 +Tm, CaSO 4 +Tm+glass and glass+Tm composites for use as thermoluminescent dosimeter (TLD). The route used to prepare the CaSO 4 +Tm and the CaSO 4 +Tm+glass was by mixing 1 g of CaSO 4 with 0.02 g of thulium oxide (99,9% purity) and 0.3 g of commercial and colorless glass. To mixing the composites were taken to a magnetic stirrer for 30 min with 10 mL of distilled water for better homogenization. The powder mixtures were dried in a stove at 100 deg C for 24 h. After drying, it was added polyvinyl alcohol (PVA) to improve the binding material. The pellets were compacted by application of an uniaxial pressing and sintered at 700 deg C/ 6 h. The route used in the preparation of glass+Tm pellets was similar to one previously mentioned, except by the use of 1 g of glass and 0.02 of Tm. After the sintering, the pellets dimensions were 1 mm thick and 6 mm in diameter. All samples were irradiated by a beta source ( 90 Sr + 90 Y) and received doses from 1.00 Gy to 20 Gy. Each composite presented a characteristic emission curve. The dosimeter of CaSO 4 +Tm+glass presented two peaks, the first at 115 deg C, and the second, very intense, ate 150 deg C. The CaSO 4 +Tm dosimeter showed a less intense peak at 140 deg C and another, more intense, at 235 deg C. In the composites of glass+Tm, the most intense peak has a thermoluminescent signal 94,04% lower than the most intense peak of CaSO 4 +Tm+glass and 81.57% lower than the most intense peak of CaSO 4 +Tm. After the analysis of TL emission curves, we observed that the CaSO 4 +Tm+glass have the highest TL intensity and a TL response proportional to the dose absorbed. (author)

  2. Calibration of TLD badge to photons of energies above 6 MeV encountered in nuclear reactors

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Bakshi, A.K.

    1999-01-01

    Response of CaSO 4 :Dy Teflon discs based TLD badge has been evaluated for radiation fields having photons of energy above 6 MeV, often encountered in nuclear power plants. Gamma ray response of the TLD disc under metal filter in the badge (used for evaluation of gamma ray doses) was found to increase by about 10% to photons above 6 MeV as compared to the response for reference calibration to 60 Co gamma rays. Response of discs under the open window and the plastic filter was found to be only 40-60% of that under metal filter. Thus, while measurement of whole body dose is not affected seriously, the estimation of beta dose in the mixed fields of high energy gamma rays and beta rays could be in serious error. In the above fields for situations having beta doses of about 1.65 times the gamma ray doses, the present use of dose evaluation will record beta dose as zero, a serious under estimation of beta ray doses. Study also provides an explanation to an anomalous situation where reading under window or plastic filter is much less than that under metal filter. These aspects of personal dosimetry need attention. (author)

  3. Effect of thermal treatment on TL response of CaSO₄:Dy obtained using a new preparation method.

    Science.gov (United States)

    González, P R; Cruz-Zaragoza, E; Furetta, C; Azorín, J; Alcántara, B C

    2013-05-01

    We report the effect of thermal treatment on thermoluminescent (TL) sensitivity property of CaSO4:Dy obtained by a new preparation method at Instituto Nacional de Investigaciones Nucleares (ININ) of Mexico. Samples of phosphor powder were subjected to different thermal treatments respectively at 773, 873, 973 and 1,173K for 1h and then irradiated from 0.1 to 1,000 Gy gamma doses. Low energy dependence was analyzed too by irradiating with X-rays in the range of 16-145 keV. The results were normalized to the energy (1,252 keV) of (60)Co and they were compared with those obtained using the commercial dosimeters TLD-100. Also the kinetic parameters were determined by deconvolution of glow curve. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Quality control in medical radiology using T.L.D

    International Nuclear Information System (INIS)

    Rolemberg Silva, F.A.; Nascimento Souza, D. do

    2006-01-01

    In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO 4 :Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 μGy and 0.35 μGy. The T.L.D. have revealed useful for the measures if the response to the dose is previously known for each set of beam parameters used for the irradiations. Otherwise, the tests with the dosimeters can serve to evaluate the beams conditions and their reproducibility. The evaluation results of coherence between the luminous fields and the irradiation fields demonstrated that the difference between the radiation and the luminous fields did not exceed 2% of the distance between the focal point and the film. We found satisfactory values for half-value layer. (author)

  5. The characteristics of CaF2:Tm crystals (TLD-300) irradiated by electromagnetic radiation

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; Yona, S.; Laichter, Y.; German, U.; Weiser, G.

    1985-09-01

    The main characteristics of the CaF 2 :Tm crystals (TLD-300), as a dosimeter, were measured: the glow curve, sensitivity, linearity, fading and energy dependence for photons, and compared to those of LiF (TLD-100) and CaF 2 :Dy (TLD-200). It was found that CaF 2 :Tm can be used for environmental dosimetry by reading the crystals after four days. (Author)

  6. Direct measurement of annual β dose using TLD on porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Xia Junding; Wang Weida; Zhou Zhixin

    1999-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of direct measurement of annual β dose using ultrathin TLD (CaSO 4 :Tm) on porcelain was studied. Since the TLD was placed into a hole left after sampling for the TL measurement, the method will not cause any new damage to the studied object. The results show that the technique is suitable for measuring annual β dose and improving accuracy of TL authentication test for both porcelain and pottery

  7. Application of artificial neural network for development of an algorithm for TLD badge system in the mixed field dosimetry of X and gamma radiation in terms of Hp(10)

    International Nuclear Information System (INIS)

    Srivastava, K.; Bakshi, A.K.; Geetha, V.; Kher, R.K.; Dhar, V.K.

    2005-01-01

    ICRU has introduced new operational quantities for individual monitoring. Therefore it is required to develop an algorithm that gives direct response of the TLD badge in terms of the operational quantities. For this purpose and also to improve the precision in the mixed fields dosimetry, two methods were studied i)- analytical method by developing an algorithm based on of higher order polynomial fit of the data points for known delivered doses and ii) use of Artificial Neural Network (ANN). Study on the response of the TLD badge system based on CaSO 4 : Dy Teflon TLD discs in the mixed fields of X and gamma radiation in terms of operational quantity Hp(10) was carried out using the prevalent algorithm, algorithm developed using higher order polynomial and neural network predicted algorithm for different proportion of dose delivered by X and gamma radiations. It was found that the uncertainties in the dose response for few fields are beyond the acceptable limit for prevalent algorithm and within the acceptable limit for other two algorithms. Algorithm based on ANN gives higher precision in the mixed field of two radiations compared to other two algorithms. (author)

  8. Production of thermoluminescent dosemeters based on MgB4O7: Dy and MgB4O7: Tm

    International Nuclear Information System (INIS)

    Souza, Luiza Freire de; Souza, Divanizia N.

    2013-01-01

    The thermoluminescent dosimetry (TL) is a well-established technique for the detection of ionizing radiation in hospitals, clinics, and industrial establishments where there is the need to quantify the radiation. For this practice is require the use phosphors which are sensitive to radiation. Some phosphors are already commonly used in this practice, for example, TLD-100 (LiF: Mg, Ti), CaSO 4 :Tm and CaSO 4 :Dy. A compound that was most recently introduced in dosimetry and has many advantageous features to detect neutrons, electrons and gamma is the magnesium tetraborate (MgB 4 O 7 ), but the undoped material is not good for dosimetry, since signal does not show satisfactory thermoluminescence. The present work presents the analysis of the compound MgB 4 O 7 when doped with rare earth elements, thulium (Tm) and dysprosium (Dy). The production of MgB 4 O 7 : Dy and MgB 4 O 7 : Tm occurred under acidic conditions. Following the process of crystal growth, several tests were made on phosphors produced to verify the quality of materials as TL dosimeter. Initially, was made the identification of the crystalline phases found in the material, using the technique of X-ray diffractometry, and then were evaluated and compared the TL emission curves of the crystals with two different types of dopants, to this, the samples were irradiated with different radiation sources: 137 Cs (0,66 MeV), 60 Co (1.25 MeV) and X-rays (0.41 MeV) and based on the results was evaluated the energy dependence of phosphors. Another characteristic analyzed, was the decay of TL signal for the material (fading). The results show that the material can be an excellent TL dosimeter when doped with rare earth elements Dy and Tm. (author)

  9. Neutron dosimetry using activation of thermoluminescent CaSO 4

    Science.gov (United States)

    Azorín, Juan; Gutiérrez, Alicia

    1984-11-01

    Sulfur activation in calcium sulfate doped with dysprosium (CaSO 4:Dy) thermoluminescent powder, which is bound in pure sulfur, has been used to measure the fast neutron dose at the tangential beam port of a Triga Mark III reactor. After a post-irradiation time of 3 d, the dosimeters were annealed at 600°C for 30 min in order to erase all the thermoluminescence acquired during the irradiation. The dosimeters were then stored to allow self-irradiation by betas from 32P produced by sulfur activation. The thermoluminescent signal accumulated during a post-irradiation time of 20 d due to a neutron fluence of 2.2 × 10 11 n/cm 2 was equivalent to an absorbed dose of 10 mGy of 60Co gamma rays. The thermoluminescence as a function of fast neutron dose fitted to a straight line on a log-log scale from 1 Gy to 10 4Gy.

  10. Evaluation of the thermoluminescent detector answers of CaSO{sub 4}:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator; Avaliacao da resposta de detectores termoluminescentes de CaSO4:Dy, LiF:Mg,Ti e microLiF:Mg,Ti na dosimetria de feixes clinicos de fotons utilizando simulador de agua

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L., E-mail: lmatsushima@usp.b, E-mail: veneziani@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes; Sakuraba, Roberto K.; Cruz, Jose C. da, E-mail: rsakuraba@einstein.b, E-mail: jccruz@einstein.b [Sociedade Beneficente Israelita Brasileira, Sao Paulo, SP (Brazil). Hospital Albert Einstein (HAE)

    2011-10-26

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO{sub 4}:Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  11. Advances in the synthesis of new Europium doped CaSO4 phosphors and their thermoluminescence characterization

    International Nuclear Information System (INIS)

    Bernal, R.; Garcia-Haro, A.R.; Machi, L.; Brown, F.; Perez-Salas, R.; Castano, V.M.; Cruz-Vazquez, C.

    2008-01-01

    Novel self-agglomerating Eu doped CaSO 4 phosphors were synthesized by a cheap, easy, and environmental friendly chemical route. Pellet-shaped sintered samples were obtained without any binding material, and exposed to beta particle irradiation. The thermoluminescence (TL) response in the 0.08-2.6 Gy dose range increased linearly as the radiation dose increased. Glow curves exhibit the most intense maximum close to 200 deg. C, and two much less intense maxima at 250 and 330 deg. C when a 5 deg. C/s heating rate is used. No TL peaks shift is observed when dose changes, which is characteristic of first order kinetics TL processes. The whole glow curve displays a remarkable stability under storage at room temperature. The main peak intensity is 2.5 times greater than that of the TLD-100. The method here reported can be used to synthesize CaSO 4 with other dopants

  12. Luminescence properties of pure and doped CaSO4 nanorods irradiated by 15 MeV e-beam

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Enani, Mohammad A.

    2014-01-01

    Calcium sulfate (CaSO 4 ) doped with proper activators is a highly sensitive phosphor used in different fields mainly for radiation dosimetry, lighting and display applications. In this work pure and doped nanorods of CaSO 4 were produced by the co-precipitation technique. Samples from this material doped with Ag, Cu, Dy, Eu and Tb were exposed to different doses of 15 MeV e-beam and studied for their thermoluminesence (TL) and photoluminescence (PL) properties. Color center formation leading to PL emissions were investigated before and after e-beam irradiation. The samples doped with rare earths elements (i.e. Dy, Eu and Tb) were observed to have thinner nanorods than the other samples and have higher absorption in the UV region. The Ag and Tb doped samples have poor TL response to e-beam, while those activated by Cu, Dy and Eu have strong glow peaks at around 123 °C. Quite linear response curves in the whole studied exposures i.e. 0.1–100 Gy were also observed in Cu and Dy doped samples. The PL results show that pure CaSO 4 nanorods have active color centers without irradiation, which could be enriched/modified by these impurities mainly rare earths and further enhanced by e-beam irradiation. Eu 3+ → Eu 2+ conversion is clearly observed in Eu doped sample after e-beam irradiation. These results show that these nanorods might be useful in lighting and display devices development

  13. TLD territorial network in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Kroutilikova, D. [National Radiation Protection Institute, Prague (Czech Republic)

    1996-12-31

    At present, there are 236 measuring points practically homogeneously distributed on the territory of the Czech Republic. 98 measuring points are distributed as local TLD-networks in the surroundings of Czech two nuclear power plants. Both of the TLD-networks are operated by the National Radiation Protection Institute in Prague. The dosimeters hitherto used are the CaSO{sub 4}:Dy-teflon detectors placed in TL-badges and shielded on both sides by energy compensation filters composed of lead and tin. Recently, a new modernization of the measuring system, type of dosimeter and methods of evaluation is under way. From 1996 the Czech Radiation Monitoring Network will be used the TLD system HARSHAW 4000, along with the type 8807 ENVIRONMENTAL DOSIMETER. The dosimeter is composed of four TL-elements - two LiF and two CaF{sub 2}, placed in a plastic badge. In addition, the CaF{sub 2} elements are shielded on both sides by energy compensation filters composed of tantalum and lead. Before the routine use of the new system a testing of the dosimeters was made. The following text summarizes the obtained results (J.K.). 4 tabs.

  14. Environmental dose measurement with microprocessor based portable TLD reader

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.

    1996-01-01

    Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

  15. Reproducibility Test for Thermoluminescence Dosimeter (TLD) Using TLD Radpro

    International Nuclear Information System (INIS)

    Nur Khairunisa Zahidi; Ahmad Bazlie Abdul Kadir; Faizal Azrin Abdul Razalim

    2016-01-01

    Thermoluminescence dosimeters (TLD) as one type of dosimeter which are often used to substitute the film badge. Like a film badge, it is worn for a period of time and then must be processed to determine the dose received. This study was to test the reproducibility of TLD using Radpro reader. This study aimed to determine the dose obtained by TLD-100 chips when irradiated with Co-60 gamma source and to test the effectiveness of TLD Radpro reader as a machine to analyse the TLD. Ten chips of TLD -100 were irradiated using Eldorado machine with Co-60 source at a distance of 5 meters from the source with 2 mSv dose exposure. After the irradiation process, TLD-100 chips were read using the TLD Radpro reader. These steps will be repeated for nine times to obtain reproducibility coefficient, r i . The readings of dose obtained from experiment was almost equivalent to the actual dose. Results shows that the average value obtained for reproducibility coefficient, r i is 6.39 % which is less than 10 %. As conclusion, the dose obtained from experiment considered accurate because its value were almost equivalent to the actual dose and TLD Radpro was verified as a good reader to analyse the TLD. (author)

  16. Environmental monitoring system with TLD

    International Nuclear Information System (INIS)

    Aguerre, L.; Carelli, J.; Gregori, B.

    2006-01-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H * (10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and 137 Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF 2 : Dy for the different radiation qualities and the relative response at 137 Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  17. Emission spectra of phosphor MgSO4 doped with Dy and Mn

    International Nuclear Information System (INIS)

    Zhang Chunxiang; Chen Lixin; Tang Qiang; Luo Daling; Qiu Zhiren

    2001-01-01

    Emission spectra of phosphor MgSO 4 doped with Dy and Dy/Mn were measured with an optical multichannel analyzer and a linear heating system whose temperature was controlled by a microcomputer. The emission spectrum bands at 480 nm and 580 nm of phosphor MgSO 4 doped with Dy were observed in the three dimensional (3D) glow curves. Compared with the 3D spectrum of CaSO 4 :Dy and the spectrum bands of MgSO 4 :Dy shows the same wavelengths which resulted from the quantum transitions among the energy levels of Dy 3 '+ ions. The intensities of the glow peaks in both spectrum bands (480 nm and 580 nm) of phosphor MgSO 4 doped with Dy/Mn were dramatically reduced except the 380 degree C glow peak

  18. Development of new dosemeters of CaSO_4

    International Nuclear Information System (INIS)

    Santos, Ana Gabryele M. dos; Junot, Danilo O.; Souza, Divanizia N.

    2016-01-01

    Thermoluminescent dosimeters (TLDs) are widely used in in vivo dosimetry because of their simple production, viability for dose determination in difficult geometries and their reusability. The motivation of this work was to produce CaSO_4 crystals doped with thulium (Tm) and analyze their thermoluminescent (TL) properties. The crystals were produced by a variation of slow evaporation route, and TL curves showed emission peaks centered around 190 ° C and 320 ° C after irradiation with a "9"0Sr /"9"0Y source. Thermoluminescent properties such as linearity, reproducibility and fading were evaluated. The CaSO_4:Tm samples produced proved feasible for dosimetry purposes. (author)

  19. Optimal selection of TLD chips

    International Nuclear Information System (INIS)

    Phung, P.; Nicoll, J.J.; Edmonds, P.; Paris, M.; Thompson, C.

    1996-01-01

    Large sets of TLD chips are often used to measure beam dose characteristics in radiotherapy. A sorting method is presented to allow optimal selection of chips from a chosen set. This method considers the variation

  20. Personal exposure control using TLD

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu; Takeda, Shinso

    1979-01-01

    In the Tokai Works of the Power Reactor and Nuclear Fuel Development Corporation (PNC), for personal exposure control, the switching from film badges to TLD badges (and also finger-ring type local dosimeters) was made in fiscal 1974. The facilities involved are a fuel reprocessing plant, a PuO 2 -UO 2 mixed fuel production facility, and a centrifugal uranium enrichment development facility. The types of radiation concerned are various, such as γ(x), β and n. The situation of personal exposure control with TLD and the dose evaluation methods for respective radiations are explained. The number of personnel subject to exposure control, including transient people, is about 2500 - 3000 per three months. The TLD badges used are a special PNC type with TLDs to measure separately γ(x), β and n. With casings made of ABS resin, the external dimensions are 76 mm x 46 mm. (J.P.N.)

  1. Environmental effects on TLD 100

    International Nuclear Information System (INIS)

    Lilley, E.; Howard, R.

    1976-01-01

    Reference is made to a recent paper by Dhar et al (Health Phys.; 25:427 (1973)) in which significant differences in the sensitivity of TLD 100 crystals following the same heat treatments in different environments, were reported. Similar work is here reported on TLD 100 at 400 0 C with half the crystals being heat treated in vacuum, irradiated and readout an then annealed in air, irradiated and readout while the other half of the crystals were air annealed and readout before vacuum annealing and readout. In both cases no significant change was detected in contrast to the results of Dhar et al. (U.K.)

  2. Indoor gamma dose measurements in Gudalore (India) using TLD

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikandan, N.; Raghunath, V.M.

    2002-01-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO 4 : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h -1 and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 μSv y -1 , for the inhabitants of mud houses to 1406.3 μSv y -1 , for those living in terrace houses made of cement and brick

  3. A TLD reader for wide range in situ dose measurement

    International Nuclear Information System (INIS)

    Deme, S; Apathy, I.; Bodnar, L.; Csoeke, A.; Hejja, I.

    1998-01-01

    A portable thermoluminescent dosemeter reader suitable for reading at the site of exposure is described. The instrument consists of a glass bulb containing the CaSO 4 :Dy thermoluminescent material laminated to the surface of an electrically heated resistive metal plate. The bulb is encapsulated in a cylindrical, pen-like metal holder made of aluminium. A one-wire-port integrated electronic programmable memory chip mounted inside the holder contains the identification code and the individual calibration parameters of the dosemeter. The aperture of the holder is normally covered by a stainless steel tube to protect the bulb from light and mechanical shocks. The tube slips backwards automatically when the dosemeter is inserted into the reader. The system is used by the Hungarian nuclear power plant. (M.D.)

  4. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  5. Minimizing TLD-DRD differences

    International Nuclear Information System (INIS)

    Riley, D.L.; McCoy, R.A.; Connell, W.D.

    1987-01-01

    When substantial differences exist in exposures recorded by TLD's and DRD's, it is often necessary to perform an exposure investigation to reconcile the difference. In working with several operating plants, the authors have observed a number of causes for these differences. This paper outlines these observations and discusses procedures that can be used to minimize them

  6. A new TLD system for space research

    International Nuclear Information System (INIS)

    Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.; Szabo, P.P.; Csoeke, A.; Ranky, M.; Akatov, Yu.A.

    1980-06-01

    A small, portable, vibration and shock resistant thermoluminescent dosemeter (TLD) system was developed to measure the cosmic radiation dose on board of a spacecraft. The TLD system consists of a special bulb dosemeter and a TLD reader. The measuring dose range of the TLD system is from 10 μGy up to 100 mGy. The TLD reader can operate on a battery; its electrical power consumption is about 5 W, its volume is about 1 dm 3 and its mass is about 1 kg. Details are given of the construction and technical parameters of the dosemeter and reader. (author)

  7. Synthesis and luminescence properties of Eu"2"+ doped CaSO_4 phosphor

    International Nuclear Information System (INIS)

    Aghalte, G.A.; Dhoble, S.J.; Pawar, N.R.

    2016-01-01

    Eu"2"+ doped CaSO_4 Phosphor were synthesized by precipitation method. PL analysis of Eu"2"+ activated CaSO_4 phosphor exhibited characteristic emission properties; CaSO_4:Eu Phosphor has received considerable attention because of its high sensitivity to X-ray and λ ray irradiation. CaSO_4:Eu phosphor powder was successfully synthesized by the wet chemical co-precipitation method. The structure morphology and luminescent properties of the phosphor were characterized by X-ray diffraction, scanning electron microscopy and photoluminescence spectroscopy

  8. Photoluminescence and thermoluminescence characterization of Eu3+- and Dy3+ -activated Ca3(PO4)2 phosphor

    International Nuclear Information System (INIS)

    Nagpure, I.M.; Saha, Subhajit; Dhoble, S.J.

    2009-01-01

    Rare-earth-doped polycrystalline Ca 3 (PO 4 ) 2 :Eu, Ca 3 (PO 4 ) 2 :Dy and Ca 3 (PO 4 ) 2 :Eu,Dy phosphors prepared by a modified solid-state synthesis has been studied for its X-ray diffraction, thermoluminescence (TL) and photoluminescence (PL) characteristics. The PL emission spectra of the phosphor suggest the presence of Eu 3+ ion in Ca 3 (PO 4 ) 2 :Eu and Dy 3+ ion in Ca 3 (PO 4 ) 2 :Dy lattice sites. The TL glow curve of the Ca 3 (PO 4 ) 2 :Eu compounds has a simple structure with a prominent peak at 228 deg. C, while Ca 3 (PO 4 ) 2 :Dy peaking at 146 and 230 deg. C. TL sensitivity of phosphors are compared with CaSO 4 : Dy and found 1.52 and 1.20 times less in Ca 3 (PO 4 ) 2 :Eu and Ca 3 (PO 4 ) 2 :Dy phosphors, respectively. The Ca 3 (PO 4 ) 2 :Eu,Dy phosphors shows switching behavior under two different excitation wavelengths and enhancement in PL intensity of Dy 3+ ions were reported. The paper discusses the photoluminescence and thermoluminescence behavior of Eu 3+ and Dy 3+ ion in Ca 3 (PO 4 ) 2 hosts, it may be applicable to solid-state lighting as well as thermoluminescence dosimetry applications.

  9. The ternary system K2SO4MgSO4CaSO4

    Science.gov (United States)

    Rowe, J.J.; Morey, G.W.; Silber, C.C.

    1967-01-01

    Melting and subsolidus relations in the system K2SO4MgSO4CaSO4 were studied using heating-cooling curves, differential thermal analysis, optics, X-ray diffraction at room and high temperatures and by quenching techniques. Previous investigators were unable to study the binary MgSO4CaSO4 system and the adjacent area in the ternary system because of the decomposition of MgSO4 and CaSO4 at high temperatures. This problem was partly overcome by a novel sealed-tube quenching method, by hydrothermal synthesis, and by long-time heating in the solidus. As a result of this study, we found: (1) a new compound, CaSO4??3MgSO4 (m.p. 1201??C) with a field extending into the ternary system; (2) a high temperature form of MgSO4 with a sluggishly reversible inversion. An X-ray diffraction pattern for this polymorphic form is given; (3) the inversion of ??-CaSO4 (anhydrite) to ??-CaSO4 at 1195??C, in agreement with grahmann; (1) (4) the melting point of MgSO4 is 1136??C and that of CaSO4 is 1462??C (using sealed tube methods to prevent decomposition of the sulphates); (5) calcium langbeinite (K2SO4??2CaSO4) is the only compound in the K2SO4CaSO4 binary system. This resolved discrepancies in the results of previous investigators; (6) a continuous solid solution series between congruently melting K2SOP4??2MgSO4 (langbeinite) and incongruently melting K2SO4??2CaSO4 (calcium langbeinite); (7) the liquidus in the ternary system consists of primary phase fields of K2SO4, MgSO4, CaSO4, langbeinite-calcium langbeinite solid solution, and CaSO4??3MgSO4. The CaSO4 field extends over a large portion of the system. Previously reported fields for the compounds (K2SO4??MgSO4??nCaSO4), K2SO4??3CaSO4 and K2SO4??CaSO4 were not found; (8) a minimum in the ternary system at: 740??C, 25% MgSO4, 6% CaSO4, 69% K2SO4; and ternary eutectics at 882??C, 49% MgSO4, 19% CaSO4, 32% K2SO4; and 880??, 67??5% MgSO4, 5% CaSO4, 27??5% K2SO4. ?? 1967.

  10. Environmental monitoring system with TLD; Sistema de monitoreo ambiental con TLD

    Energy Technology Data Exchange (ETDEWEB)

    Aguerre, L.; Carelli, J.; Gregori, B. [Autoridad Regulatoria Nuclear Argentina (Argentina)]. e-mail: laguerre@cae.arn.gov.ar

    2006-07-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H{sup *}(10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and {sup 137} Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF{sub 2}: Dy for the different radiation qualities and the relative response at {sup 137} Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  11. An automated thermoluminescence dosimetry (TLD) system

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.

    1979-01-01

    In the Health Physics Division of the Eindhoven University of Technology work is going on in developing an automated TLD-system. Process automization, statistical computation, dose calculation as well as dose recording are carried out, using a microcomputer and floppy disk unit. The main features of this TLD-system are its low costs, flexibility, easy to operate, and the feasibility for use in routine dosimetry as well as in complex TLD research. Because of its modular set-up several components of the system are multifunctional in other operations. The system seems suited for medium sized Health Physics groups. (Auth.)

  12. Improvement of routes and production of CaSO4-based dosimeters with unusual doping

    International Nuclear Information System (INIS)

    Junot, Danilo Oliveira

    2017-01-01

    The widespread use of ionizing radiation in medicine and industry, associated with the known risks that this type of radiation can cause, has motivated the search for new radiation detectors, seeking improvements in the dosimetric characteristics and in the cost of production in comparison with commercial dosimeters disseminated. The motivation of this work is, therefore, to produce new thermoluminescent detectors through improved routes. Unusual elements in CaSO 4 matrix doping, such as terbium (Tb) and ytterbium (Yb), were used as dopants in this matrix, as well as the europium (Eu), the thulium (Tm) and the silver (Ag), resulting in samples of CaSO 4 :Eu,Tb, CaSO 4 :Tb,Yb, CaSO 4 :Tm,Ag and CaSO 4 :Eu,Ag that were prepared by means of an adaptation of the method developed by Yamashita (1971). The route of synthesis is based on the mixture of calcium carbonate (CaCO 3 ) and dopant oxide (except for silver, incorporated in the form of metallic nanoparticles) in a solution of sulfuric acid. The mixture is heated until all the acid evaporates and only the powder of the material remains. In this route, the sulfuric acid is collected and can be reused. The phosphors produced were characterized by X-ray diffraction and radioluminescence techniques. The silver particles, produced by the polyol method, were characterized by scanning electron microscopy. Composites were obtained from the addition of Teflon to the phosphors. The thermoluminescence (TL) and the optically stimulated luminescence (OSL) of the new materials produced were investigated. Thermoluminescent characteristics such as sensitivity, linearity, reproducibility, minimum detectable dose, kinetic order and fading were evaluated and discussed. The CaSO 4 :Tb,Eu composites showed TL glow curves with peaks at temperatures of 170 °C, 270 °C and 340 °C. The CaSO 4 :Tb,Yb composites presented TL glow curves with peaks at temperatures of 90 °C, 160 °C, 240 °C and 340 °C. CaSO 4 :Tm showed peaks at temperatures of 140 °C and 225 °C and the CaSO 4 :Tm,Ag presented peaks at temperatures of 140 °C, 280 °C and 380 °C. All composites showed a linear and reproducible dose response. The TL emission spectrum of the composites was also evaluated. The samples of calcium sulfate doped with europium and silver particles (CaSO 4 :Eu,Ag) showed great potential for applicability in the OSL dosimetry. (author)

  13. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1991-12-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facilities throughout the country for the third quarter of 1991

  14. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  15. Development of quality assurance procedures for thermoluminescent CaSO sub 4 :Dy-teflon skived tape dosemeter

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Kher, R.K.; Varadharajan, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1992-01-01

    CaSO{sub 4}:Dy-Teflon TLD dosemeter material has been manufactured locally in a 0.4 mm thick continuous tape form. Fourteen batches have been examined for physical thickness, density, spectral transmission, diffuse optical density, beta transmission and TL output per unit area for evolving a procedure for quality assurance of the TLD element for large scale production. With the exception of two batches, the TL output per unit area of the tape for a number of batches lies within {+-}7% of that for a standard batch. (author).

  16. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  17. Removal of Calcium from Scheelite Leaching Solution by Addition of CaSO4 Inoculating Crystals

    Science.gov (United States)

    Liu, Wenting; Li, Yongli; Zeng, Dewen; Li, Jiangtao; Zhao, Zhongwei

    2018-04-01

    In this work, the solubility behaviors of gypsum and anhydrite in the H2SO4-H3PO4-H2O system were investigated over the temperature range T = 30-80°C, and the results showed that the solubility of anhydrite was considerably lower than that of gypsum. On the basis of the differential solubilities of gypsum and anhydrite, a method was developed to remove calcium from the scheelite leaching solution by adding anhydrite as an inoculating crystal. The effects of the reaction time, concentration of the CaSO4 inoculating crystals, and temperature were investigated. With an addition of CaSO4 inoculating crystals at a concentration of 60 g/L, the Ca2+ concentration of the scheelite leaching solution decreased to a low level of approximately 0.76 g/L after 10 h at 70°C.

  18. Numerical simulation of calcium sulfate (CaSO4) fouling in the plate heat exchanger

    Science.gov (United States)

    Xu, Zhiming; Zhao, Yu; Han, Zhimin; Wang, Jingtao

    2018-07-01

    Plate heat exchanger is a widely used apparatus in the industrial production processes. Through a numerical simulation method, this paper calculates the deposition rate of CaSO4 fouling on heat transfer surfaces of the plate heat exchanger under saturation in the bulk. The effects of CaSO4 concentration in the range 0.7 kg/m3 to 1.5 kg/m3, inlet flow velocity under turbulent flow, and the fluid's inlet temperature from 288 K to 328 K on the deposition rate, removal mass rate and fouling resistance are investigated. The simulation results are compared with the experimental results showing similar trend. The simulation results show that the concentration and the flow velocity affect significantly the fouling characteristics in the plate heat exchanger. The deposition mass rate, removal mass rate, and asymptotic value of fouling resistance all increase with the increase in CaSO4 concentration and the inlet temperature of the hot fluid, while the asymptotic value of fouling resistance decreases with the increasing of inlet flow velocity. The influence of the inlet temperature of cold fluid may be negligible.

  19. Nanophosphor CaSO4:Eu2+ for photoluminescence liquid crystal display (PLLCD)

    Science.gov (United States)

    Patle, Anita; Patil, R. R.; Moharil, S. V.

    2018-05-01

    In this work PL enhancement of CaSO4:Eu2+ nanophosphor which was synthesized with 0.01M molarity by co-precipitation method is presented. Synthesized phosphor was characterized by XRD, SEM, TEM and PL measurements. Average particle size is found to be in the range 80-100nm with Hexagonal morphology and PL studies showed emission peaks at 380nm, when samples were excited by 254nm. The observed PL emission is characteristic emission of Eu2+ similar to that observed in bulk CaSO4:Eu2. However under identical condition it is observed that intensity of emission get enhanced for 0.01M size which is doubled to that of 0.1M with similar emission at 380nm. A phosphor with narrow emission band around 390 nm is desirable, since at this wavelength the transmission of standard glass, polarizing plastic, other coating and LCD material is at acceptable level. Strong Eu2+ emission is observed in CaSO4:Eu nanophosphor which finds applications for PLLCD (photoluminescent liquid crystal display).

  20. Numerical simulation of calcium sulfate (CaSO4) fouling in the plate heat exchanger

    Science.gov (United States)

    Xu, Zhiming; Zhao, Yu; Han, Zhimin; Wang, Jingtao

    2018-01-01

    Plate heat exchanger is a widely used apparatus in the industrial production processes. Through a numerical simulation method, this paper calculates the deposition rate of CaSO4 fouling on heat transfer surfaces of the plate heat exchanger under saturation in the bulk. The effects of CaSO4 concentration in the range 0.7 kg/m3 to 1.5 kg/m3, inlet flow velocity under turbulent flow, and the fluid's inlet temperature from 288 K to 328 K on the deposition rate, removal mass rate and fouling resistance are investigated. The simulation results are compared with the experimental results showing similar trend. The simulation results show that the concentration and the flow velocity affect significantly the fouling characteristics in the plate heat exchanger. The deposition mass rate, removal mass rate, and asymptotic value of fouling resistance all increase with the increase in CaSO4 concentration and the inlet temperature of the hot fluid, while the asymptotic value of fouling resistance decreases with the increasing of inlet flow velocity. The influence of the inlet temperature of cold fluid may be negligible.

  1. Neutron area monitor with TLD pairs

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Borja H, C. G.; Valero L, C.; Hernandez D, V. M.; Vega C, H. R.

    2011-11-01

    The response of a passive neutron area monitor with pairs of thermoluminescent dosimeters has been calculated using the Monte Carlo code MCNP5. The response was calculated for one TLD 600 located at the center of a polyethylene cylinder, as moderator. When neutrons collide with the moderator lose their energy reaching the TLD with thermal energies where the ambient dose equivalent is calculated. The response was calculated for 47 monoenergetic neutron sources ranging from 1E(-9) to 20 MeV. Response was calculated using two irradiation geometries, one with an upper source and another with a lateral source. For both irradiation schemes the response was calculated with the TLDs in two positions, one parallel to the source and another perpendicular to the source. The advantage of this passive neutron monitor area is that can be used in locations with intense, pulsed and mixed radiation fields. (Author)

  2. Improvements of RGD3 TLD reader

    International Nuclear Information System (INIS)

    Zhao Jianxing; Wang Jiaqi; Li Yuanfang; Wu Furong; Xiao Wuyun

    1999-01-01

    The author summarized the main features of the improved RGD3 TLD reader. Through a large number of experiments some persuasive data are obtained, which show that an remarkable improvement has been achieved, especially in its stability to the standard illuminates, data dispersivity, and effectiveness to glow curves analysis. Working with the newly developed data processing software, the comprehensive performance of the whole system will be enhanced greatly

  3. Determination of the TLD-100 physical parameters

    International Nuclear Information System (INIS)

    Paucar J, J.; Picon C, C.

    1998-01-01

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  4. Microcomputer control of automated TLD reader

    International Nuclear Information System (INIS)

    Bjarland, Bert.

    1979-10-01

    The interfacing electronics, the control algorithms and the developed programs of a 6800 microcomputer controlled automated TLD reader are described. The TL reading system is implemented with a photomultiplier tube and a charge-to-pulse converter. The gain of the TL reading system is controlled through the use of a temperature compensated LED reference light source. Automatic compensation of PM tube dark current is optional. The short term stability of TL readings is better than 3 %. (author)

  5. Ionizing radiation source detection by personal TLD

    International Nuclear Information System (INIS)

    Marinkovic, O.; Mirkov, Z.

    2002-01-01

    The Laboratory for personal dosimetry has about 3000 workers under control. The most of them work in medicine. Some institutions, as big health centers, have different ionizing radiation sources. It is usefull to analyze what has been the source of irradiation, special when appears a dosimeter with high dose. Personal dosimetry equipment is Harshaw TLD Reader Model 6600 and dosimeters consist of two chips LiF TLD-100 assembled in bar-coded cards which are wearing in holders with one tissue-equivalent filter (to determine H(10)) and skin-equivalent the other (to determine H(0.07)). The calibration dosimeters have been irradiated in holders by different sources: x-ray (for 80keV and 100keV), 6 0C o, 9 0S r (for different distances from beta source) and foton beem (at radiotherapy accelerator by 6MeV, 10MeV and 18MeV). The dose ratio for two LiF cristals was calculated and represented with graphs. So, it is possible to calculate the ratio H(10)/H(0.07) for a personal TLD and analyze what has been the source of irradiation. Also, there is the calibration for determination the time of irradiation, according to glow curve deconvolution

  6. Next Generation Model 8800 Automatic TLD Reader

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Streetz, K.L.; Rotunda, J.E.

    1999-01-01

    BICRON NE has developed an advanced version of the Model 8800 Automatic TLD Reader. Improvements in the reader include a Windows NT TM -based operating system and a Pentium microprocessor for the host controller, a servo-controlled transport, a VGA display, mouse control, and modular assembly. This high capacity reader will automatically read fourteen hundred TLD Cards in one loading. Up to four elements in a card can be heated without mechanical contact, using hot nitrogen gas. Improvements in performance include an increased throughput rate and more precise card positioning. Operation is simplified through easy-to-read Windows-type screens. Glow curves are displayed graphically along with light intensity, temperature, and channel scaling. Maintenance and diagnostic aids are included for easier troubleshooting. A click of a mouse will command actions that are displayed in easy-to-understand English words. Available options include an internal 90 Sr irradiator, automatic TLD calibration, and two different extremity monitoring modes. Results from testing include reproducibility, reader stability, linearity, detection threshold, residue, primary power supply voltage and frequency, transient voltage, drop testing, and light leakage. (author)

  7. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  8. How to diagnose any type of TLD Reader?; Como diagnosticar cualquier tipo de TLD Reader?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso, E-mail: manolo@cphr.edu.cu, E-mail: jotag@cphr.edu.cu, E-mail: alex@cphr.edu.cu, E-mail: stefan@cphr.edu.cu, E-mail: andy@cphr.edu.cu, E-mail: gilberto@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included.

  9. RFID based TLD monitoring system - a prospective development

    International Nuclear Information System (INIS)

    Jeevanram, S.S.; Pawar, S.T.; Mahule, K.N.; Rath, D.P.

    2008-01-01

    Thermo Luminescence Dosimetry (TLD) is an established method of monitoring the radiation dose received by workers in radiation environments. In Radiometallurgy Laboratory, BARC, the TLD movement inside a nuclear facility is completely carried out by a radiation worker. However, there is a chance that the TLDs may get lost in laboratories or some places without the knowledge of the concerned TLD user or health physicist. It may later lead to a false effective dose. Effort is being done to initiate a RFID based TLD monitoring system so that the use of TLD can be acknowledged through a self operating software which can prevent misuse of the detector. A novel method of improving the administrative control through Radio Frequency Identification (RFID) based monitoring to avoid such inadvertent misplacement of TLD, is in progress. This paper discusses the method and techniques through which administrative control can be exercised to reduce the number of such in explainable exposures. (author)

  10. Postal TLD audit in radiotherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Kapucianova, M.; Ekendah, D. l.; Bulanek, B.

    2014-01-01

    The postal TLD audit in radiotherapy is an independent check of dose applied by radiotherapy centers. Our poster provides basic information on the methodology of dose determination within the TLD audit. An overview of different versions of the TLD audit that are focused on specific techniques in radiotherapy is given. We also present results of so called basic version of the TLD audit that is performed regularly for purposes of the State Office for Nuclear Safety. Moreover, results of intercomparison measurements organized by the IAEA (International Atomic Energy Agency), in which our laboratory takes part every year, are shown.The methodology of dose determination is based on TL measurement of LiF:Mg,Ti powder. The TL dosemeter (TLD) has form of a plastic capsule containing approximately 160 mg of this material. Before the TL reading, the powder of each particular irradiated dosemeter is divided into 9 identical samples by means of an accurate dispenser. The dosemeter response is given as average of TL responses of the 9 samples. The dose absorbed in water is computed from the TLD response by application of calibration factor and correction coefficients for elimination of energy dependence, supra-linearity and fading of the TL material. The evaluation of the TLD audit is based on comparison of the dose measured by the TLD and the dose stated by a radiotherapy center. Relative deviation between these doses is calculated. Several versions of the TLD audit are available. (authors)

  11. A personnel TLD system with person identification

    International Nuclear Information System (INIS)

    Widell, C.O.

    1974-01-01

    The TLD system uses Li 2 B 4 O 7 :Mn, Si sintered tablets which are heated by hot nitrogen. The slide which holds the tablets is coded by a self adhesive polyester-aluminium tape. This tape is BCD coded in an ordinary tape punch. The information on the punched tape includes a ten digit social-security number and a two digit information on location and type of dosimetry. By this system dosimetric data is directly transfered into a central dose register for Sweden. All personnel doses are there stored on social-security numbers. (author)

  12. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  13. Environmental monitoring with TLD in Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.; Mora, E.

    2003-01-01

    Using thermoluminescent dosimeters (Harshaw TLD-200) the first set of costarican data on absorbed doses in air from natural radiation is obtained. During the period from September 1996 to october 2000 eight different sites throughout the country were chosen to instal the TLD stations. Each station had eight cards (five were changed every three months and three changed annually). The dosimeters were read in the Applied Nuclear Physics Laboratory using a 4000 Harshaw reader and with the help a mathematical algorithm and the equipment calibration factors the dose rate in air (nGy h -1 ) was calculated. The national average is 108.9 ± 32.4 nGy h -1 , the lowest values (in nGy h -1 ) were obtain at sea level at Quebrada Honda with 53 ± 11 and the highest values (in nGy h -1 ) at Cartago with 160 ± 19. A slight increase with altitude is observed even though the Cartago station was always the highest. The values found agree with reported worldwide values for environmental doses in air. (Author) [es

  14. Experience of TLD personnel monitoring laboratory

    International Nuclear Information System (INIS)

    Jakhete, Prashant

    2002-01-01

    Full text: Renentech Laboratories is the first Private Enterprise in India to have been chosen to provide Personnel radiation monitoring services to radiation workers at different parts of the country. Since 1992 the Company has been manufacturing TLD phosphor powder of requisite quality and from 1995 commenced the production of TLD cards for radiation monitoring. After getting the necessary approval from the competent authorities in the country, the company undertook a rigorous quality assurance programme and received the accreditation in 1999 to carry out the personnel monitoring of radiation. Since then the trained staff of the Company is covering 1200 institutions in 16 states where radiation is being used. This translates to processing of 60,000 Till cards annually, the maximum limit permitted by BARC. Processing of exposure data is done strictly according well-laid guidelines. Any cases of overexposure are immediately referred to Calibration and Dose Record Section of BARC to meet the regulatory requirements. Necessary procedural guidelines are followed to handle such cases. In this lecture, learning, operation and implementation experience of a typical Private Company in a task, which, hitherto had been regarded as exclusive responsibility of state owned institution, is enumerated

  15. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1992-06-01

    The US Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network is operated by the NRC in cooperation with participating states to provide continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. Ambient radiation levels result from naturally occurring radionuclides present in the soil, cosmic radiation constantly bombarding the earth from outer space, and the contribution, if any, from the monitored facilities and other man-made sources. The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels used to assess the radiological impact of an unusual condition, such as an accident. This report presents the radiation levels measured around all facilities in the Network for the first quarter of 1992. All radiation measurements are made using small, passive detectors called thermoluminescent dosimeters (TLDs), which provide a quantitative measurement of the radiation levels in the area in which they are placed. Each site is monitored by arranging approximately 40 to 50 TLD stations in two concentric rings extending to about five miles from the facility. All TLD stations are outside the site boundary of the facility

  16. An environmental TLD for nuclear power plants

    International Nuclear Information System (INIS)

    Marcinowski, F.

    1988-01-01

    In this paper a dosimeter is proposed for the purpose of detecting noble gas releases (principally Xe-133) from nuclear power plants. The dosimeter consists of two Li 2 B 4 O 7 :Cu (LiBO) elements and one CaSO 4 :Tm (CaSO) element. One LiBO element is enclosed only in plastic and is used to determine shallow dose, while the LiBO and CaSO pair, which are used to determine deep dose, are enclosed in a 1070 mg/cm 2 aluminum sphere and plastic. The dosimeter is designed to overcome the three major problems involved in monitoring for Xe-133: the effect of angular response, differences in irradiation geometry (overhead plume vs. submersion), and interference from naturally occurring high-energy gamma rays. Laboratory test data are presented to demonstrate the proposed dosimeter's response characteristics

  17. Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Taylor, M.L.

    2011-01-01

    Lithium fluoride thermoluminescent dosimeters (TLD) are the most commonly implemented for clinical dosimetry. The small physical magnitude of TLDs makes them attractive for applications such as small field measurement, in vivo dosimetry and measurement of out-of-field doses to critical structures. The most broadly used TLD is TLD-100 (LiF:Mg,Ti) and, for applications requiring higher sensitivity to low-doses, TLD-100H (LiF:Mg,Cu,P) is frequently employed. The radiological properties of these TLDs are therefore of significant interest. For the first time, in this study effective atomic numbers for radiative, collisional and total electron interaction processes are calculated for TLD-100 and TLD-100H dosimeters over the energy range 1 keV-100 MeV. This is undertaken using a robust, energy-dependent method of calculation rather than typical power-law approximations. The influence of dopant concentrations and unwanted impurities is also investigated. The two TLDs exhibit similar effective atomic numbers, ranging from approximately 5.77-6.51. Differences arising from the different dopants are most pronounced in low-energy radiative effects. The TLDs have atomic numbers approximately 1.48-2.06 times that of water. The effective atomic number of TLD-100H is consistently higher than that of TLD-100 over a broad energy range, due to the greater influence of the higher-Z dopants on the electron interaction cross sections. Typical variation in dopant concentration does not significantly influence the effective atomic number. The influence on TLD-100H is comparatively more pronounced than that on TLD-100. Contrariwise, unwanted hydroxide impurities influence TLD-100 more than TLD-100H. The effective atomic number is a key parameter that influences the radiological properties and energy response of TLDs. Although many properties of these TLDs have been studied rigorously, as yet there has been no investigation of their effective atomic numbers for electron interactions. The

  18. CaSO4 Scale Formation on Vibrated Piping System in the Presence Citric Acid

    Science.gov (United States)

    Mangestiyono, W.; Jamari, J.; Muryanto, S.; Bayuseno, A. P.

    2018-02-01

    Vibration in many industries commonly generated by the operation mechanical equipment such as extruder, mixer, blower, compressor, turbine, generator etc. Vibration propagates into the floor and attacks the pipe around those mechanical equipment. In this paper, the influence of vibration in a pipe on the CaSO4 scale formation was investigated to understand the effect of vibration on the kinetics, mass of scale, crystal phases and crystal polymorph. To generate vibration force, mechanical equipment was prepared consisted of electrical motor, crankshaft, connecting rod and a vibration table at where test pipe section mounted. Deposition rate increased significantly when the vibration affected to the system i.e. 0.5997 and 1.6705 gr/hr for vibration frequency 4.00 and 8.00 Hz. The addition 10.00 ppm of citric acid declined the deposition rate of 8 Hz experiment from 3.4599 gr/hr to 2.2865 gr/hr.

  19. Determination of the TLD-100 physical parameters; Determinacion de parametros fisicos del TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Paucar J, J.; Picon C, C. [Instituto Nacional de Enfermedades Neoplasicas. INEN. Av. Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  20. New advanced TLD system for space dosimetry

    International Nuclear Information System (INIS)

    Feher, I.; Szabo, B.; Vagvoelgyi, J.; Deme, S.; Szabo, P.P.; Csoeke, A.

    1983-10-01

    A new version of the TLD reader type PILLE has been developed for space applications. The earlier compact and portable device could also be used for measurements during space flights but its range was limited. A new bulb detector with easier handling has also been developed with an upper limit of linear dose response of 10 Gy. The range of this new and more versatile reader, NA206S, (1μGy-10 Gy) is 3 orders of magnitude higher than that of the earlier system; it also has increased sensitivity and decreased mass. It can be used not only in space applications but also for environmental monitoring or even in accident dosimetry. The measured dose value is displayed on a four-digit display with automatic range switch. Another new version, the NA206E, has been developed for environmental dosimetry; it can be operated from a battery or from the mains. (author)

  1. The IAEA/WHO TLD postal programme for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Izewska, J.; Andreo, P.

    2000-01-01

    Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the number of participants and reduced significantly the total turn-around time to provide results to the hospitals within the shortest possible time following the TLD irradiations. The IAEA has established a regular follow-up programme for hospitals with results outside acceptance limits of ±5%. The IAEA has, over 30 years, verified the calibration of more than 3300 clinical photon beams at approximately 1000 radiotherapy hospitals. Only 65% of those hospitals who receive TLDs for the first time have results within the acceptance limits, while more than 80% of the users that have benefited from a previous TLD audit are successful. The experience of the IAEA in TLD audits has been transferred to the national level. The IAEA offers a standardized TLD methodology, provides Guidelines and gives technical back-up to the national TLD networks. The unsatisfactory status of the dosimetry for radiotherapy, as noted in the past, is gradually improving however, the dosimetry practices in many hospitals in developing countries need to be revised in order to reach adequate conformity to hospitals that perform modern radiotherapy in Europe, USA and Australia. (author)

  2. X-rays individual dose assessment using TLD dosimeters

    International Nuclear Information System (INIS)

    Salas, Carlos

    2008-01-01

    This paper describes the methodology used in Embalse NPP for measuring individual X-ray dose in dentists and radiologists, who work in areas near the plant. Personnel is provided with TLD personal dosimeters for thoracic use, as well as TLD ring dosimeters. This individual X-ray dosimetry is fundamental in order to know the effective energy coming from the radiation field, since the dosimetry factors depend on it. On the other hand, the response of the TLD crystals also depends of the effective energy; this accentuates the problem when assessing the individual dose. The X-ray dosimeter must simultaneously determine the value of the effective energy and the corresponding dose value. The basic principle for determining effective energy is by using at least two different TLD materials covered by filters of different thickness. The TLD materials used have totally energy responses. Therefore, different readouts from each of the crystals are obtained. The ratio between both readouts provides a factor that depends of the effective energy but that is 'independent' from the exposure values irradiated to the dosimeter. The Personal TLD dosimeter currently in use is Bicron-Harshaw. It comprises a carrier model 8807. This carrier contains a card model 2211 which groups two TLD 200 crystals and two TLD 100 crystals. It has internal filters at each side of the TLD 200 crystals. The periodical calibration of these dosimeters consists in the irradiation of some dosimeters with different X-ray energy beams in the National Atomic Energy Commission (CNEA). This dosimeter was used, by the National Regulatory Authority (ARN) in several comparisons, always getting satisfactory results. (author)

  3. TLD audit in radiotherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Zackova, H.; Judas, L.

    1998-01-01

    National Radiation Protection Institute in Prague organizes the TLD audit. The aim of the TLD postal audit is to provide control of the clinical dosimetry in the Czech Republic for purposes of state supervision in radiotherapy, to investigate and to reduce uncertainties involved in the measurements of absorbed dose and to improve consistency in dose determination in the regional radiotherapy centers. TLD audit covers absorbed dose measurements under reference conditions for 60 Co and 137 Cs beams, high-energy X-ray and electron beams of of linear accelerators and betatrons. The thermo-luminescence dosemeters are sent regularly to all radiotherapy centers. Absorbed dose measures by the TLD is compared to absorbed dose stated by radiotherapy center. Encapsulated LiF:Mg, Ti powder is used for the measurement. Deviation of 3% between stated and TLD measured dose is considered for photons and ±5% for electron beams. First TLD audit was started in 1997. A total of 135 beams was checked. There were found seven major deviations (more than ±6%), which were very carefully investigated. Medical Physicists from these departments reported a set-up mistake. However, at most of those hospitals with major deviations, an in situ audit in details was made soon after TLD audit. There were found discrepancies of clinical dosimetry but also bad technical state of some of the irradiation units. In 1998, second course TLD audit was started. No major deviation was found. Regular TLD audit seems to be a good way to eliminate big mistakes in the basic clinical dosimetry. Repeated audit in the regional radiotherapy centers that had major deviation during the first audit exhibited improvement of their dosimetry. It is intended to broaden the method and to control also beam parameters by means of a multi-purpose phantom. (authors)

  4. Relative efficiency of the radiothermoluminescence induced by 238Pu alpha-particles in LiF:Mg, Al2O3 and CaSO4:Dy

    International Nuclear Information System (INIS)

    Vicy, Masok.

    1978-01-01

    This work represents a comparative study of the radiothermoluminescence (R.T.L.) induced by 60 Co gamma rays and 238 Pu alpha-particles in three R.T.L. materials: lithium fluoride, alumina and dysprosium activated calcium sulphate. The T.L. glow curves induced by the two radiations are very similar. However, for the same absorbed dose, different sensitivity is seen to each form of irradiation. Measurements of the relative R.T.L. efficiency, epsilon, were made in the linear zone (dose [fr

  5. TLD audit in the radiotherapy at the national level

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Zackova, H.; Novotny, J.; Pridal, I.

    1998-01-01

    Czech legislation requires that all radiotherapy departments undertake quality independent audit annually. An authorized auditing group was created as a body of the National Radiation Protection Institute. It has been decided that TLD postal audit combined with film dosimetry would alternate with in situ audit every two or three years. For this, a local TLD measuring network has been established. The methods applied in the TLD audit were taken from EROPAQ and EURAQA projects in 1996 and modified to comply with Czech local circumstances. First TLD audits were started in February 1997. During the February to September period, 60 beams were checked: 26 Co-60 beams, 10 Cs-137 beams, 15 X-ray beams, and 9 electron beams. Details of the measurements and their results are given. (P.A.)

  6. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.

    Science.gov (United States)

    Kroutilķková, Daniela; Novotný, Josef; Judas, Libor

    2003-02-01

    The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.

  7. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, Daniela; Novotny, Josef; Judas, Libor

    2003-01-01

    Introduction: The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. Materials and methods: The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of ±3% are considered acceptable for both basic and advanced mode of the audit. Results: There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. Conclusions: The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres

  8. Dosimetric characteristics of a TLD dosemeter with extremities; Caracteristicas dosimetricas de un dosimetro TLD de extremidades

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Diaz B, E.; Lien V, R. [Centro de Proteccion e Higiene de las Radiaciones, CPHR, Apdo.Postal 6195, Habana 6, CP 10600, Ciudad Habana (Cuba)

    1999-07-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm{sup 3} covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  9. Estimation of uncertainty in TLD calibration

    International Nuclear Information System (INIS)

    Hasabelrasoul, H. A.

    2013-07-01

    In this study thermoluminescence dosimeter TLD was use of individual control devices to make sure the quality assurance and quality control in individual monitoring. The uncertainty measured in reader calibration coefficients for tow reader and uncertainty in radiation dose after irradiate in SSDL laboratory. Fifty sample was selected for the study was placed in the oven at a temperature of 400 for an hour to get zero or background and took zero count by or background and took zero count by reader (1) and reader (2) and then irradiate in SSDL by cesium-137 at a dose of 5 mGy and laid back in the oven at degrees 100 and degrees 10 minutes, to 10 chips for calibration and readout count by reader one and reader two. The RCF was found for each reader above 1.47 and 1.11, respectively, and found the uncertainty RCF was found for each reader above 1.47 and 1.11, respectively, and found the uncertainly RCF 0.430629 and 0.431973. Radiation dose was measured for fifty samples irradiate to dose of 5 mGy and read the count by reader 1 and reader 2 the uncertainty was found for each reader 0.490446 and 0.587602.(Author)

  10. 161Dy Moessbauer spectroscopy of the intermetallic compounds DyNi2Si2, DyNi2Ge2 and DyAg2Si2

    International Nuclear Information System (INIS)

    Onodera, Hideya; Murata, Akifumi; Koizuka, Masaaki; Ohashi, Masayoshi; Yamaguchi, Yasuo

    1994-01-01

    161 Dy Moessbauer spectroscopic study has been performed on DyNi 2 Si 2 , DyNi 2 Ge 2 and DyAg 2 Si 2 in order to clarify microscopic properties of antiferromagnets with incommensurate and sinusoidally moment-modulated structure. The experiments were done using the standard 161 Tb Moessbauer sources prepared by neutron irradiation at the Japan Material Testing Reactor. The Moessbauer spectra of DyNi 2 Si 2 are analyzed satisfactorily by a single set of hyperfine parameters, and hence the sinusoidal moment-modulation is considered to be realized through a distribution of spin relaxation rate. The broadened spectra of DyNi 2 Ge 2 are fitted tentatively by three subspectra. It seems for DyNi 2 Ge 2 that the incommensurate arrangement of Dy moments differed in magnitude as well as the distribution of spin relaxation rate originates the moment modulation. The fact that the spectrum of DyAg 2 Si 2 at 3 K consists of two distinct subspectra ensures the complicated antiferromagnetic structure where two kinds of Dy moments differed in magnitude are arranged noncollinearly. (author)

  11. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Freire, L. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Laboratorio de Medicina Nuclear, Lda, Atomedical, Rua Helena Felix, 11D, 1600-121 Lisboa (Portugal); Calado, A.; Cardoso, J.V.; Santos, L.M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Alves, J.G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt

    2008-02-15

    In this work the results aimed at assessing the performance of two types of LiF detectors, TLD-100 and TLD-100H, used in the context of extremity dosimetry are presented. Each detector variety was studied for reproducibility, batch homogeneity, residual dose, linearity and energy dependence using, when appropriate, the {sup 90}Sr/{sup 90}Y radiation source built-in one of the Harshaw 6600 readers, the ISO narrow X-ray beams of N30, N40, N60, N80, N100 and N120 or the gamma radiations of {sup 137}Cs and {sup 60}Co. Two calibration energies (N120 and {sup 137}Cs) were also used. The reproducibility and linearity results indicate that both LiF:Mg,Ti and LiF:Mg,Cu,P performed equally well. However, LiF:Mg,Cu,P presents a higher residual signal. In terms of energy dependence, LiF:Mg,Cu,P shows less variation than LiF:Mg,Ti particularly when N120 is used as calibration radiation. This seems to be a more realistic setup since the energy of the most frequently used radioisotopes in Nuclear Medicine departments with single photon emission computed tomography (SPECT) use gamma radiation energies closer to N120 than to {sup 137}Cs.

  12. Extra Dose Due to Extravehicular Activity During the NASA4 Mission, Measured by an On-Board TLD System

    Energy Technology Data Exchange (ETDEWEB)

    Deme, S.; Apathy, I.; Hejja, I.; Lang, E.; Feher, I. [Budapest (Hungary)

    1999-07-01

    A microprocessor-controlled on-board TLD system, 'Pille'96', was used during the NASA4 (1997) mission to monitor the cosmic radiation dose inside the Mir Space Station and to measure the extra dose to two astronauts in the course of their extravehicular activity (EVA). For the EVA dose measurements, CaSO{sub 4}:Dy bulb dosemeters were located in specially designed pockets of the ORLAN spacesuits. During an EVA lasting 6 h, the dose ratio inside and outside Mir was measured. During the EVA, Mir crossed the South Atlantic Anomaly three times. Taking into account the influence of these three crossings the mean EVA/internal dose rate ratio was 3.2. Internal dose mapping using CaSO{sub 4}:Dy dosemeters gave mean dose rates ranging from 9.3 to 18.3 {mu}Gy.h{sup -1} at locations where the shielding effect was not the same. Evaluation results of the high temperature region of LiF dosemeters are given to estimate the mean LET. (author)

  13. Diffusion processes in dyed detectors

    International Nuclear Information System (INIS)

    Lferde, M.; Seidel, J.-L.; Monnin, M.

    1982-01-01

    In order to get a better understanding of the dyed and fluorescent track detectors, the diffusion speed of the swelling agent, the sensitization molecules and the dye have been measured under various conditions. It is shown that the sensitization affects the entire detector while dyeing is restricted to the upper and lower layers of the detector. By combining the optimal values of the reactions parameters a higher contrast and sensitivity may be achieved. (author)

  14. Measurement of TLD Albedo response on various calibration phantoms

    International Nuclear Information System (INIS)

    Momose, T.; Tsujimura, N.; Shinohara, K.; Ishiguro, H.; Nakamura, T.

    1996-01-01

    The International Commission on Radiation Units and Measurements (ICRU) has recommended that individual dosemeter should be calibrated on a suitable phantom and has pointed out that the calibration factor of a neutron dosemeter is strongly influenced by the the exact size and shape of the body and the phantom to which the dosemeter is attached. As the principle of an albedo type thermoluminescent personal dosemeter (albedo TLD) is essentially based on a detection of scattered and moderated neutron from a human body, the sensitivity of albedo TLD is strongly influenced by the incident neutron energy and the calibration phantom. (1) Therefore for albedo type thermoluminescent personal dosemeter (albedo TLD), the information of neutron albedo response on the calibration phantom is important for appropriate dose estimation. In order to investigate the effect of phantom type on the reading of the albedo TLD, measurement of the TLD energy response and angular response on some typical calibration phantoms was performed using dynamitron accelerator and 252 Cf neutron source. (author)

  15. TLD array for precise dose measurements in stereotactic radiation techniques

    International Nuclear Information System (INIS)

    Ertl, A.; Kitz, K.; Griffitt, W.; Hartl, R.F.E.; Zehetmayer, M.

    1996-01-01

    We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy. (author)

  16. Nano-fibrin stabilized CaSO4 crystals incorporated injectable chitin composite hydrogel for enhanced angiogenesis & osteogenesis.

    Science.gov (United States)

    Arun Kumar, R; Sivashanmugam, A; Deepthi, S; Bumgardner, Joel D; Nair, Shantikumar V; Jayakumar, R

    2016-04-20

    Calcium sulfate (CaSO4), an excellent biodegradable bone forming agent that is an ideal choice as additive in gels, however, its disadvantage being poor gel rheology and angiogenesis. Here, we have synthesized chitin-CaSO4-nano-fibrin based injectable gel system which shows improved rheology and angiogenic potential. Rheological studies showed that the composite gel was a shear thinning gel with elastic modulus of 15.4±0.275kPa; a 1.67 fold increase over chitin control. SEM and XRD analyses revealed the effect of nano-fibrin (nFibrin) in transforming CaSO4 crystal shape from needle to hexagonal. It also masked the retarding effect of CaSO4 towards in vitro early cell attachment and angiogenesis using rabbit adipose derived mesenchymal stem cells (rASCs) and HUVECs, respectively. rASCs osteogenesis was confirmed by spectrophotometric endpoint assay, which showed 6-fold early increase in alkaline phosphatase levels and immuno-cytochemistry analysis. These in vitro results highlight the potential of injectable chitin-CaSO4-nFibrin gel for osteo-regeneration via enhanced angiogenesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Magnetic properties of Dy/Zr multilayers

    International Nuclear Information System (INIS)

    Luche, M.C.; Boyer, P.

    1992-01-01

    [Dy(xA)/Zr(30A)] n superlattices (x ≤ 30), were evaporated under ultra-high vacuum on Si(100) substrates. Magnetization measurements indicate that the antiferromagnetic transition occurring at 178K in bulk Dy is suppressed in the multilayers. This phenomenon is attributed to magnetoelastic effects induced by strains at Zr/Dy interfaces. A perpendicular magnetic anisotropy takes place for x ≤ 15. However, the magnetic anisotropy is found to depend markedly on the technique used for Dy deposition. (author). 11 refs., 4 figs

  18. Energy dependence of thermoluminescent response of CaSO{sub 4}:Dy, LiF:Mg and micro LiF:Mg,Ti in clinical beams of electrons by using different simulator objects; Dependencia energetica da resposta TL de dosimetros de CaSO{sub 4}:Dy, LiF:Mg e microLiF:Mg,Ti em feixes clinicos de eletrons utilizando diferentes objetos simuladores

    Energy Technology Data Exchange (ETDEWEB)

    Bravim, Amanda; Campos, Leticia Lucente, E-mail: abravin@ipen.b, E-mail: rsakuraba@einstein.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Cruz, Jose Carlos da, E-mail: rsakuraba@einstein.b, E-mail: josecarlosc@einstein.b [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-10-26

    Yet not so widely applied in radiotherapy, the calcium sulfate doped with dysprosium (CaSO{sub 4}:Dy) is used in radioprotection and studies has been demonstrated its great potential for the dosimetry in radiotherapy. This work evaluates the energy dependence of the thermoluminescent answer of the CaSO{sub 4}:D, LiF:Mg,Ti (TLD-100) and micro LiF:Mg,Ti in clinical beams of electrons by using water simulators, PMMA and solid water

  19. Thermoluminescent dosimeters for low dose X-ray measurements

    International Nuclear Information System (INIS)

    Del Sol Fernández, S.; García-Salcedo, R.; Sánchez-Guzmán, D.; Ramírez-Rodríguez, G.; Gaona, E.; León-Alfaro, M.A. de; Rivera-Montalvo, T.

    2016-01-01

    The response of TLD-100, CaSO_4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm"2 at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO_4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO_4:Dy showed a linearity from 0.1 to 60 mGy - Highlights: • Low dose X-ray doses for personal dosimetry were measured. • Radiation dose (µGy ) for environmental dosimetry were determined. • Scattering radiation dose were measured by TLDs. • Linearity of pair TLD system was successful in the range of microgray. • Pair TLDs composed by CaSO_4:Dy and by LiF:Mg,Cu,P. is suggested for clinical dosimetry.

  20. Data processing of personnel exposure in TLD and film systems

    International Nuclear Information System (INIS)

    Lerner, A.; Liav, N.; Eisen, Y.

    1979-01-01

    The program for the processing and storage of data on the personnel irradiation exposure in Israel is built on the data base of the Weizmann Institute of Science; it is a general program suitable for both TLD and film dosimetry. The TSO system helped bring up-to-date the data of the various collections in an interactive way. The introduction of the TLD dosemeters in the badge service required certain changes in the thinking line - this because the TLD being a personal dosemeter is returned into service after having been deciphered. This demands following up the dosemeter when the worker moves from unit to unit or after he had finished his work. The program takes into account the internal exposures,too and conforms to the new recommendation published in ICRP-26. (B.G.)

  1. How to diagnose any type of TLD Reader?

    International Nuclear Information System (INIS)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso

    2013-01-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included

  2. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  3. Study of physical factors affecting the TLD readout

    International Nuclear Information System (INIS)

    Ahmed, Amira Abd Elrhman Ebrahim

    2015-10-01

    The aim of the study was to study the effects of physical factors in TLD reading. The dosimeters have been irradiated with x rays of (0.5 mGy to 5 mGy) using plastic holder with Aluminum filters with dimensions 1.5 x 0.8 mm and 0.5 mm in thickness to obtain the equivalent dose Hp (10) flux of nitrogen gas and annealing after data collection by TLD Reader Analyzer 04 (Version 0.9.400 micro lab (krakow 2012). The count and dose analysis shows that; The count/s given by TLD appears to be higher in case of using filtration which was 7189.9 eps in contrast with reading without filter which was 4055.8 eps. There was proportional linear relationship between the applied dose and the TLD count for both cases with and without filter. And the correlation could be fitted in the form of equations: y=423.9 x + 1023 and y = 432.5 x + 405.3 for filtered and y refers to count/s. Such increment in count is ascribed to increasing applied radiation dose as well it indicates and confirms the linearity of TLD in measuring the radiation dose since R 2 = 0.9. However the count with filter for the applied radiation dose in mGy was greater than that without filter. The that measured with pellets annealing (reading of zero doses). TLD pellets reading without zero dose measurement usually gives greater dose ( 441.8 and 563.6 μGy) relative to the case where the zero doses have been measured which were 289.6 and 429.2 μGy, respectively. While the effect of using filtration is so obvious and leads to increase of zero dose, respectively relative to dose s of un reading of zero dose, and reading of zero dose, but without filter.(Author)

  4. Investigation of thermoluminescent response of K2YF5:Dy3+ crystals for gamma and X radiation fields

    International Nuclear Information System (INIS)

    Silva, E.C.; Nogueira, M.S.; Faria, L.O.; Khaidukov, N.M.

    2005-01-01

    K 2 YF 5 crystals doped with rare earths have been synthesized with 0 to 100% of Dy 3+ ions optically active ions and an investigation was conducted to test its thermoluminescent (TL) response due to function of Dy 3+ concentration and their response in energy. After being irradiated with gamma and X-rays, it was observed that crystals doped with 1.0% of Dy 3+ feature the best response TL. The main dosimetric peak can be decomposed into three secondary TL peaks, centered in 96.4, 104.9 and 130.7 deg C, respectively, showing a good linearity and reproducibility of the dose measurements. The sensitization process seems to improve response TL and TL peak sensitivity increase to 130, 7 deg C at the expense of TL peak to 104, 9 deg C. The linear coefficient sign TL for K 2 Y 0.09 Dy 0.01 F5 is comparable to that of the dosemeter CaSO 4 : Mn, irradiated with gamma radiation source ( 137 Cs) under the same conditions. Energy dependence measurements show that the answer for X-rays with energy of 41.1 keV is more than 30 times the response to Cs-137, when exposed to the same dose. Due to the main peak in low temperature and the TL high reply to low energy fields, the results reported indicate that the K 2 YF 5 crystals doped with Dy 3+ present great potential for radiation dosimetry in X-rays therapy, clinical dosimetry and also for applications in digital thermoluminescent images

  5. Differences in TLD 600 and TLD 700 glow curves derived from distict mixed gamma/neutron field irradiations

    International Nuclear Information System (INIS)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D.

    2013-01-01

    In Neutron Capture Therapy, a thermal neutron beam shall impinge on a specific nuclide, such as 10 B, to promote a nuclear reaction which releases the useful therapeutic energy. A nuclear reactor is usually used as the neutron source, and therefore field contaminants such as gamma and high energy neutrons are also present in the field. However, mixed field dosimetry still stands as a challenge in some cases, due to the difficulty to experimentally discriminate the dose from each field component. For the mixed field dosimetry, the International Commission on Radiation end Units (ICRU) recommends the use of detector pairs with different responses for each beam component. The TLD 600/700 pair meets this need, because these LiF detectors have different Li isotopes concentration, with distinct thermal neutron responses because 6 Li presents a much higher neutron capture cross section than does 7 Li for low energy neutrons. TLD 600 is 6 Li enriched while TLD 700 is 7 Li enriched. However, depending on the neutron spectrum presented in the mixed field, TLD 700 response to thermal neutrons cannot be disregarded. This work aims to study the difference in TLD 600 and TLD 700 glow curves when these TLDs are submitted to mixed fields of different energy spectra and components balance. The TLDs were irradiated in a pure gamma source, and in mixed fields from an AmBe sealed source and from the IPEN/MB-01 reactor. These TLDs were read and had their two main dosimetric regions analyzed to observe the differences in the glow curves of these TLDs in each irradiation. Field components discrimination was achieved through Monte Carlo simulations run with MCNP radiation transport code. (author)

  6. Band mixing in /sup 160/Dy

    Energy Technology Data Exchange (ETDEWEB)

    Hasiza, M L; Singh, K; Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1982-11-01

    The intensities of the gamma transitions in /sup 160/Dy have been measured precisely by a 45 cc Ge(Li) detector. Unequal quadrupole moments for the ground and gamma vibrational bands have been proposed in order to remove the inconsistencies in the values of band mixing parameter Z sub(gamma) for this doubly even deformed nucleus of /sup 160/Dy.

  7. Towards an automated TLD system that meets international requirements

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.; Vanamo, V.

    1988-01-01

    The new recently introduced fully automated TLD system developed by Alnor OY on the basis of the Riso prototype, is intended to meet draft IEC/ISO proposals and ANSI requirements. Part of the system is a personal dosemeter badge and an environmental dosemeter package following ICRU recommendations. The overall system consists of a software-controlled automated reader, a programable irradiator/calibrator, a computer, and dosemeters for environmental, whole body, extremity and clinical applications. The personal TLD badge that contains four TLD pellets is designed to agree with ICRU H p (10) and H s (0.07) quantities for determining dose equivalent. The badge can accommodate a large variety of the most commonly used solid TL dosemeter products. A special effort was put into the evaluation of skin dose by considering the use of graphite-mixed hot-sintered LiF pellets. The TLD system is described and results from a performance test that comprised measurements of photon energy response, angular dependence, and reproducibility are presented

  8. Periodicity of TLD badge personnel monitoring service in India

    International Nuclear Information System (INIS)

    Kher, R.K.; Joshi, V.D.; Kaushik, Aruna; Sharma, Amiy; Chatterjee, S.

    2003-01-01

    The periodicity of an individual monitoring service is an important aspect. Presently minimum period for TLD badge service is maintained as 'calendar month' and choice of quarterly service is also offered. The periodicity of the TLD service for a given category/application type of institution, is to be fixed taking into account level of average occupational doses in all or typical institutions of given category and other information indicating the status of safety and possible fluctuations of exposure levels and potential for overexposure cases. This paper presents the status on the periodicity of TLD Badge Service as is evolved and adopted for the four broad categories i.e. DAE (Nuclear Fuel Cycle) Institutions, Industrial, Medical, Research institutions. It is concluded that quarterly service is a convenient option for institution categories where type of work/workload, and work practices are such that occupational exposures could be normally kept below about one mSv or so in the monitoring period, average annual dose less than 1 mSv and persons receiving annual dose >10 mSv is less than 1% of total in the category. Also, the judicious use of the flexibility in the periodicity of TLD Badge service would help (i) to keep the monitoring related workload to the optimum for the monitoring units and (ii) to keep the expenses incurred by the institution towards monitoring to the minimum without sacrificing radiation safety (iii) to focus the extra monitoring efforts on the applications/situations requiring improvement in radiation safety. (author)

  9. Magnetic moments of high spin rotational states in 158Dy and 164Dy+

    International Nuclear Information System (INIS)

    Seiler-Clark, G.

    1983-09-01

    For the study of their magnetic moments yrast states in 158 Dy and 164 Dy were excited via the multiple-Coulomb excitation by a 4.7 MeV/u 208 Pb beam. Hereby especially the question was of interest, how the one-particle effects in the nuclear structure in the region of the backbending anomaly in 158 Dy take effects on the g-factors of the high spin states in this region. The particle-γ angular correlations perturbed in the transient magnetic field during the passing of the excited Dy ions through a thin magnetized iron foil were measured. By the selective position-sensitive detection of Dy recoil ions and Pb projectiles under forward angles it was possible to determine additionally to the g-factors in the backbending region also g-factors in the spin region I 158 Dy and 164 Dy by detection of the particle-γ correlations precessing in the static hyperfine field after implantation in iron. The static hyperfine field was at the 4 + state in 164 Dy determined to B (Dy,Fe) = 245+-25 T. The g-factors were determined by comparison of the experimental results with calculations of the perturbed angular correlations by time-differential regarding of the population and de-excitation of the yrast states as well as by precession and hyperfine-relaxation effects during the flight of the Dy ions in the vacuum. (orig./HSI) [de

  10. Compound effect of CaCO3 and CaSO4·2H2O on the strength of steel slag: cement binding materials

    International Nuclear Information System (INIS)

    Qi, Liqian; Liu, Jiaxiang; Liu, Qian

    2016-01-01

    In this study, we replaced 30% of the cement with steel slag to prepare binding material; additionally, small amounts of CaCO 3 and CaSO 4 ·2H 2 O were added. This was done to study the compound effect of CaCO 3 and CaSO 4 ·2H 2 O on the strength of steel slag-cement binding materials. The hydration degree of the steel slag cementitious material was analyzed by XRD, TG and SEM. The results showed that the optimum proportions of CaCO 3 and CaSO 4 ·2H 2 O were 3% and 2%, respectively. Compared with the steel slag-cement binders without adding CaCO 3 and CaSO 4 ·2H 2 O, the compressive strength increased by 59.9% at 3 days and by 17.8% at 28 days. Acting as the nucleation matrix, CaCO 3 could accelerate the hydration of C 3 S. In addition, CaCO 3 was involved in the hydration reaction, generating a new hydration product, which could stably exist in a slurry. Meanwhile, CaSO 4 ·2H 2 O could increase the number of AFt. The compound effect of CaCO 3 and CaSO 4 ·2H 2 O enhanced the intensity of steel slag-cement binding materials and improved the whole hydration behavior. (author)

  11. Introducing 2D barcode on TLD cards - a step towards automation in personnel monitoring

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Annalakshmi, O; Rajagopal, V.; Santhanam, R.; Jose, M.T.

    2018-01-01

    As part of personnel monitoring services, TLD lab, RSD, IGCAR issues and receives large numbers of TLD cards every month, for use by occupational workers belonging to various hot facilities at Kalpakkam. Considering the nature of the work being manual, routine, labour intensive and being prone for human errors, introducing automation would be necessary at the TLD lab as well as at the user facility. This requires identification of the individual components of the TLD and embed them with unique identification for the system to accomplish the task. The paper discusses the automation part related to the TLD cards

  12. DySectAPI: Scalable Prescriptive Debugging

    DEFF Research Database (Denmark)

    Jensen, Nicklas Bo; Karlsson, Sven; Quarfot Nielsen, Niklas

    We present the DySectAPI, a tool that allow users to construct probe trees for automatic, event-driven debugging at scale. The traditional, interactive debugging model, whereby users manually step through and inspect their application, does not scale well even for current supercomputers. While...... lightweight debugging models scale well, they can currently only debug a subset of bug classes. DySectAPI fills the gap between these two approaches with a novel user-guided approach. Using both experimental results and analytical modeling we show how DySectAPI scales and can run with a low overhead...

  13. Dosimetric quality control in radiotherapy using TLD methodology

    International Nuclear Information System (INIS)

    Saravi, M.C.; Kessler, C.; Alvarez, P.E.; Feld, D.B.

    2002-01-01

    In the frame of the IAEA Co-ordinated Research Project 'Development of a Quality Assurance Program for Radiation Therapy Dosimetry in Developing Countries' a Dosimetric Quality Control Group was set up in Argentina in 1996, to develop a program in order to improve radiotherapy in the country. Nowadays, this Group, briefly called External Audit Group (EAG), is composed by the national Secondary Standard Dosimetry Laboratory (SSDL), which has the responsibility for dose determinations, traceability to international dosimetry chain and TLD measurements, and two Medical Physicists from CNEA who are working at the Oncology Hospital 'Marie Curie' in Buenos Aires. The present paper reports the activities performed by the EAG with external high energy photon beams in reference conditions and the results of two pilot studies on cobalt 60 beams in non-reference conditions. The first step of the program was to update the existing data base about the radiotherapy centres operating in the country. A form was sent to each of them in order to obtain basic information about their staff, number and type of treatment machines, brachytherapy sources, measuring devices, beam calibration, treatment planning system, simulator and other relevant data. 90 radiotherapy centres were registered in the EAG data base. Forms were completed by 75/90 centres. There are nowadays 69 cobalt 60 units and 42 LINACs operating in the country (18/42 LINACs producing high energy X ray and electron beams). EAG deals with measurements performed with mailed TLD irradiated at radiotherapy centres. Internal quality control on our TLD system is made during each audit by means of reference capsules irradiated by IAEA; external controls consist in blind tests performed by IAEA once a year. The correction factor, K en , determined at our SSDL for high energy X-rays was checked with the collaboration of IAEA and Prague National Radiation Protection Institute (PNRPI) by means of a blind test. Results for 4 MV, 6 MV

  14. Molecular assembly and magnetic dynamics of two novel Dy6 and Dy8 aggregates.

    Science.gov (United States)

    Guo, Yun-Nan; Chen, Xiao-Hua; Xue, Shufang; Tang, Jinkui

    2012-04-02

    Complexation of dysprosium(III) with the heterodonor chelating ligand o-vanillin picolinoylhydrazone (H(2)ovph) in the presence of a carbonato ligand affords two novel Dy(6) and Dy(8) clusters, namely, [Dy(6)(ovph)(4)(Hpvph)(2)Cl(4)(H(2)O)(2)(CO(3))(2)]·CH(3)OH·H(2)O·CH(3)CN (2) and [Dy(8)(ovph)(8)(CO(3))(4)(H(2)O)(8)]·12CH(3)CN·6H(2)O (3). Compound 2 is composed of three petals of the Dy(2) units linked by two carbonato ligands, forming a triangular prism arrangement, while compound 3 possesses an octanuclear core with an unprecedented tub conformation, in which Dy(ovph) fragments are attached to the sides of the carbonato core. The static and dynamic magnetic properties are reported and discussed. In the Dy(6) aggregate, three Dy(2) "skeletons", having been well preserved (see the scheme), contribute to the single-molecule-magnet behavior with a relatively slow tunneling rate, while the Dy(8) cluster only exhibits a rather small relaxation barrier.

  15. Photon energy response of an aluminum oxide TLD environmental dosimeter

    International Nuclear Information System (INIS)

    Olsher, R.H.

    1992-01-01

    Because of aluminum oxide's significant advantage in sensitivity (about a factor of 30) over LiF, minimal fading characteristics and ease of processing, aluminum oxide thermoluminescent dosimeters (TLDS) are being phased in at Los alamos for environmental monitoring of photon radiation. The new environmental dosimeter design consists of a polyethylene holder, about 0. 5 cm thick, loaded with a stack of four aluminum oxide TLD chips, each 1 mm thick and 5 mm in diameter. As part of the initial evaluation of the new design, the photon energy response of the dosimeter was calculated over the range from 10 keV to 1 MeV. Specific goals of the analysis included the determination of individual chip response in the stack, assessment of the response variation due to TLD material (i.e., LiF versus A1 2 O 3 ), and the effect of copper filtration in flattening the response

  16. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  17. Environmental radiation measurements using TLD in and around AERE, Dhaka

    International Nuclear Information System (INIS)

    Mollah, A.S.; Husain, S.R.; Rahman, M.M.

    1986-01-01

    The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y -1 in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984. (author)

  18. Meeting regulatory standards with BeO ceramic TLD

    International Nuclear Information System (INIS)

    Gammage, R.B.; Christian, D.J.

    1978-01-01

    Measurements of exposures below 1 mR are possible with BeO ceramic TLD by signal recording that discriminates against an interfering pyroelectric incandescence. Performance under environmental monitoring conditions is considered in light of current regulatory criteria. Factors such as reproducibility and batch uniformity are satisfactory. An anomalous energy dependence causes an over-response that will probably require use of an energy compensation shield

  19. Asteroids Dynamic Site-AstDyS

    Science.gov (United States)

    Knezevic, Zoran; Milani, Andrea

    2012-08-01

    The AstDyS online information service (http://hamilton.dm.unipi.it/astdys/) contains data on numbered and multi - opposition asteroids, including orbital elements, their uncertainty, proper elements, ephemerides with uncertainty, and more. AstDyS also provides additional scientific output computed from the raw observational data. This value added currently includes: more accurate orbits computed with advanced dynamical and observational error model s; their uncertainty, as expressed by the covariance matrix formalism; ephemerides computed on request for each observer, with uncertainty; mean and proper orbital elements (for this output, AstDyS is the primary source worldwide); statistical quality control, providing a rigorous observational error model. All this is available with a sophisticated web interface, providing multiple search functions and online computations as well as complete orbital and residual files. There are several ways in which the A stDyS service could be expanded and improved in the next future, like the explicit classification of asteroids into asteroid families, the classification of resonant asteroids, and an updated self - consistent population model (to be used, e.g., for survey simulations). The IAU Division I endorsed the proposal for AstDyS to become an IAU (permanent) service, which would include the IAU supervision of the AstDyS system, keeping under control the quality of the work and the continuous update under conditions of scientific competition.

  20. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  1. Centralized TLD service and record keeping in Canada

    International Nuclear Information System (INIS)

    Grogan, D.; Ashmore, J.P.; Bradley, R.P.

    1979-01-01

    A centralized automated TLD service operated by the Department of National Health and Welfare went into operation in May 1977 to monitor radiation workers throughout Canada. Twenty-thousand employees from a wide range of disciplines are enrolled and the number will be increased to fifty thousand by September l978. A prototype of the system, operational from September 1976 to May 1977 for three-thousand people, has already been described. A description of technical and operational highlights is presented as well as a description of problems experienced during the first full year of operation. Details of costs, conversion logistics, operational performance and technical problems are included. A comparison of the advantages and disadvantages of changing from film dosimetry to TLD in a nationwide context is detailed. The dose meter read-out unit is interfaced, through video terminals, with a time-sharing computer system programmed to provide direct access to the Canadian National Dose Registry. Details of this linkage are described, as are the computer programmes for routine processing of raw batch data. The centralized TLD service interactively linked with the National Dose Registry provides a comprehensive occupational monitoring programme invaluable for regulatory control. (author)

  2. Investigation of the thermoluminescent response of K2GdF5:Dy3+ crystals to photon radiation and neutron fields

    International Nuclear Information System (INIS)

    Silva, Edna C.; Faria, Luiz O.; Santos, Joelan A.L.; Vilela, Eudice C.

    2009-01-01

    The thermoluminescent (TL) properties of undoped and Dy 3+ doped K 2 GdF 5 crystals were investigated from the point of view of gamma and neutron dosimetry. Crystalline K 2 GdF 5 platelets with thickness of about 1 mm and doped with 0.0, 0.2, 1.0, 5.0 and 10.0 at.% Dy 3+ ions, synthesized under hydrothermal conditions, were irradiated in order to study TL sensitivity, as well as dose and energy response, reproducibility and fading. As it has been turned out, crystals doped with 5.0 at% Dy 3+ show the most efficient TL response and demonstrate a linear response to doses for all the radiation fields. TL glow curves from Dy 3+ doped K 2 GdF 5 crystals can be deconvoluted into four individual TL peaks centered at 153, 185, 216 and 234 deg C. Concerning the photon fields studied, the maximum TL response has been found for the 52.5 keV photons. The intensity is 15 times more than that of the response for the 662 keV photons from a Cs-137 source. On the other hand, the K 2 GdF 5 crystals doped with 5.0 at % Dy 3+ have also been found to have the better TL response for fast neutron radiation, among all dopants studied. For fast neutron radiation produced by a 241 Am-Be source, the TL responses for doses were also linear and comparable to that of commercial TLD-600, irradiated at same conditions. It has been established that the gamma sensitivity of the crystals is about 0.07% of the neutron sensitivity and the fast neutron sensitivity is about 4.5 % of the thermal neutron sensitivity. These results points out that K 2 Gd 0.95 Dy 0.05 F 5 crystals are good candidates for use in neutron dosimetry applications. (author)

  3. Self-shielding factors for TLD-600 and TLD-100 in an isotropic flux of thermal neutrons

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Dubi, A.; Ben Shahar, B.

    1976-01-01

    The applications of lithium fluoride thermoluminescent dosemeters in mixed n-γ environments, and the dependence of LiF-TL on linear energy transfer are both topics of current interest. Monte Carlo calculations have therefore been carried out to determine the thermal neutron absorption probability (and consequently the self-shielding factor) for an isotropic flux of neutrons impinging on different sized cylindrical samples of LiF TLD-100 and TLD-600. The calculations were performed for cylinders of radius up to 10 cm and heights of 0.1 to 1.5 cm. The Monte Carlo results were found to be significantly different from the analytic calculations for infinitely long cylinders, but, as expected, converged to the same value for (r/h) << 1. (U.K.)

  4. Heterogeneous bilayer films NiFe (Fe)-Dy: magnetic circular dichroism and Dy spin ordering

    Energy Technology Data Exchange (ETDEWEB)

    Markov, V.V. E-mail: ise@iph.krasn.ruise@iph.krasnoyarsk.su; Kesler, V.G.; Khudyakov, A.E.; Edelman, I.S.; Bondarenko, G.V

    2001-08-01

    Results of the magnetic circular dichroism (MCD) and Auger electron spectroscopy (AES) investigations in the 3d transition metal-Dy bi-layer films are presented. It is shown that even at room temperature the Dy layer makes a contribution to MCD of the bi-layer film, which corresponds to the MCD value in the single-layer Dy film measured below T{sub C}=85 K. According to the AES data there is no sharp interface between 3d and Dy layers in these films. Some amount of Ni and Fe atoms is dispersed in the Dy layer and some amount of Dy atoms is dispersed in the 3d layer. The comparison of the MCD and AES data allows one to suppose the Dy layer in the bi-layer films to be magnetically ordered at room temperature under the influence of the 3d-layer spin system. The influence spreads to long distances inside Dy layer through the 3d-ions dispersed in it.

  5. Heterogeneous bilayer films NiFe (Fe)-Dy: magnetic circular dichroism and Dy spin ordering

    International Nuclear Information System (INIS)

    Markov, V.V.; Kesler, V.G.; Khudyakov, A.E.; Edelman, I.S.; Bondarenko, G.V.

    2001-01-01

    Results of the magnetic circular dichroism (MCD) and Auger electron spectroscopy (AES) investigations in the 3d transition metal-Dy bi-layer films are presented. It is shown that even at room temperature the Dy layer makes a contribution to MCD of the bi-layer film, which corresponds to the MCD value in the single-layer Dy film measured below T C =85 K. According to the AES data there is no sharp interface between 3d and Dy layers in these films. Some amount of Ni and Fe atoms is dispersed in the Dy layer and some amount of Dy atoms is dispersed in the 3d layer. The comparison of the MCD and AES data allows one to suppose the Dy layer in the bi-layer films to be magnetically ordered at room temperature under the influence of the 3d-layer spin system. The influence spreads to long distances inside Dy layer through the 3d-ions dispersed in it

  6. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

    Science.gov (United States)

    Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel

    2014-01-01

    High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by (241)Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy(-1) for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy(-1) achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.

  7. Developmental roles of the BMP1/TLD metalloproteinases.

    Science.gov (United States)

    Ge, Gaoxiang; Greenspan, Daniel S

    2006-03-01

    The astacin family (M12A) of the metzincin subclan MA(M) of metalloproteinases has been detected in developing and mature individuals of species that range from hydra to humans. Functions of this family of metalloproteinase vary from digestive degradation of polypeptides, to biosynthetic processing of extracellular proteins, to activation of growth factors. This review will focus on a small subgroup of the astacin family; the bone morphogenetic protein 1 (BMP1)/Tolloid (TLD)-like metalloproteinases. In vertebrates, the BMP1/TLD-like metalloproteinases play key roles in regulating formation of the extracellular matrix (ECM) via biosynthetic processing of various precursor proteins into mature functional enzymes, structural proteins, and proteins involved in initiating mineralization of the ECM of hard tissues. Roles in ECM formation include: processing of the C-propeptides of procollagens types I-III, to yield the major fibrous components of vertebrate ECM; proteolytic activation of the enzyme lysyl oxidase, necessary to formation of covalent cross-links in collagen and elastic fibers; processing of NH2-terminal globular domains and C-propeptides of types V and XI procollagen chains to yield monomers that are incorporated into and control the diameters of collagen type I and II fibrils, respectively; processing of precursors for laminin 5 and collagen type VII, both of which are involved in securing epidermis to underlying dermis; and maturation of small leucine-rich proteoglycans. The BMP1/TLD-related metalloproteinases are also capable of activating the vertebrate transforming growth factor-beta (TGF-beta)-like "chalones" growth differentiation factor 8 (GDF8, also known as myostatin), and GDF11 (also known as BMP11), involved in negative feedback inhibition of muscle and neural tissue growth, respectively; by freeing them from noncovalent latent complexes with their cleaved prodomains. BMP1/TLD-like proteinases also liberate the vertebrate TGF

  8. Some Limitations in the Use of Plastic and Dyed Plastic Dosimeters

    DEFF Research Database (Denmark)

    Miller, Arne; Bjergbakke, Erling; McLaughlin, W. L.

    1975-01-01

    Several practical plastic and dyed plastic dosimeters were examined under irradiation conditions similar to those used for radiation processing of materials. Cellulose triacetate, polymethyl methacrylate, polyvinyl chloride, dyed polymethyl methacrylate, dyed Cellophane and dyed Nylon were given...

  9. IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Bera, P.; Vatnitsky, S.

    2002-01-01

    Since 1969 the International Atomic Energy Agency, together with the World Health Organization, has performed postal TLD audits to verify calibration of radiotherapy beams in developing countries. The TLD programme also monitors activities of Secondary Standard Dosimetry Laboratories (SSDLs). The programme has checked approximately 4000 clinical beams in over 1100 hospitals, and in many instances significant errors have been detected in the beam calibration. Subsequent follow-up actions help to resolve the discrepancies, thus preventing further mistreatment of patients. The audits for SSDLs check the implementation of the dosimetry protocol in order to assure proper dissemination of dosimetry standards to the end-users. The TLD audit results for SSDLs show good consistency in the basic dosimetry worldwide. New TLD procedures and equipment have recently been introduced by the IAEA that include a modified TLD calibration methodology and computerised tools for automation of dose calculation from TLD readings. (author)

  10. Efeitos de relações CaSO4/CaCO3 na mobilidade de nutrientes no solo e no crescimento do algodoeiro

    Directory of Open Access Journals (Sweden)

    A. A. Silva

    1998-09-01

    Full Text Available O experimento, realizado em casa de vegetação no Departamento de Ciência do Solo da Universidade Federal de Lavras, teve por objetivo estudar o efeito de diferentes relações de CaSO4/CaCO3, que simulam o uso de gesso e calcário, na movimentação de nutrientes no solo e no crescimento do algodoeiro, cultivar IAC-20. As proporções de CaSO4/CaCO3 utilizadas foram: 0/100, 25/75, 50/50, 75/25 e 100/0, com base em peso equivalente, além de um tratamento-testemunha, sem aplicação de CaSO4 e CaCO3. Observou-se acentuada movimentação de cálcio e de sulfato em profundidade, como íons acompanhantes, com o aumento da relação CaSO4/CaCO3. Para o N-NO3- e Mg2+, ao contrário do N-NH4+ e K+, observou-se um acúmulo em profundidade, com a elevação da relação CaSO4/CaCO3. Neste estudo, o gesso teve pouco ou nenhum efeito sobre a acidez e Al trocável presentes nas camadas subsuperficiais. A produção de matéria seca do algodoeiro foi reduzida com o aumento da relação CaSO4/CaCO3, porém, quando comparada à do tratamento-testemunha, a aplicação de gesso aumentou-a significativamente, atestando o potencial de uso do gesso agrícola.

  11. Ten years experience with a large computerized TLD-personnel monitoring system

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1986-01-01

    It is now ten years since our Institute for Radiation Protection has fully replaced its filmdosimetry service by a computerized automated TLD system. Presently more than 13000 radiation workers are monthly monitored by three automated TLD readers linked to the computer center. The paper describes system hardware and software and experience gained in long-term routine operation. In particular the introduction of the new ICRU quantities for personnel dosimetry in the existing TLD system is discussed. (Author)

  12. Influence of Dy in solid solution on the degradation behavior of binary Mg-Dy alloys in cell culture medium.

    Science.gov (United States)

    Yang, Lei; Ma, Liangong; Huang, Yuanding; Feyerabend, Frank; Blawert, Carsten; Höche, Daniel; Willumeit-Römer, Regine; Zhang, Erlin; Kainer, Karl Ulrich; Hort, Norbert

    2017-06-01

    Rare earth element Dy is one of the promising alloying elements for magnesium alloy as biodegradable implants. To understand the effect of Dy in solid solution on the degradation of Mg-Dy alloys in simulated physiological conditions, the present work studied the microstructure and degradation behavior of Mg-Dy alloys in cell culture medium. It is found the corrosion resistance enhances with the increase of Dy content in solid solution in Mg. This can be attributed to the formation of a relatively more corrosion resistant Dy-enriched film which decreases the anodic dissolution of Mg. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  14. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Klamert, V. [Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Agosteo, S. [INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Birattari, C.; Gay, S. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [FIS-ION, ENEA, Casaccia, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF{sub 2}:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different {sup 6}Li percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity. (authors)

  15. Mechanoluminescence of Dy doped strontium aluminate nanophosphors

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Ravi, E-mail: rvsharma65@gmail.com [Department of Physics, Govt. Arts and Commerce Girls College, Raipur, C.G. 492001 (India); Bisen, D.P. [School of Studies in Physics and Astrophysics, Pt. Ravishankar Shukla University, Raipur, C.G. 492010 (India); Chandra, B.P. [Department of Postgraduate Studies and Research in Physics and Electronics, Rani Durgavati University, Jabalpur 482001 (India)

    2015-12-15

    Nanosized strontium aluminate phosphors activated with Dy{sup 3+} were prepared by a combustion method. Nanophosphor was prepared by this method at reaction temperatures as low as 600 °C. Powder X-ray diffraction (XRD), scanning electron microscope analysis was used to characterize the prepared product. The monoclinic phase was observed in the XRD pattern. The particle size of the samples was calculated around 35 nm. The SEM images show irregular shape of the prepared nanophosphor. Two peaks were found in the mechanoluminescence (ML) response curve plotted between time and ML intensity. The H{sub 3}BO{sub 3} added strontium aluminate phosphors activated with Dy show more bright ML peak as compared to the powders of SrAl{sub 2}O{sub 4}:Dy{sup 3+} without H{sub 3}BO{sub 3.} It was found that the PL and ML intensity increases with increasing concentration of Dy, it becomes maximum for 3% of Dy. The photoluminescence emission shows two intense fluorescence transitions peaks at 498 nm and 583 nm, {sup 4}F{sub 9/2}→{sup 6}H{sub 15/2} in the blue and {sup 4}F{sub 9/2}→{sup 6}H{sub 13/2} in the yellow-orange wavelength region. - Highlights: • Combustion synthesis route is used to prepare the SrAl{sub 2}O{sub 4}: Dy {sup 3+} nanophosphors. • The size of the synthesized sample was found to be in the nano-meter range. • The mechanoluminescence of SrAl{sub 2}O{sub 4}:Dy {sup 3+} nanophosphors is studied. • The photoluminescence of SrAl{sub 2}O{sub 4}: Dy {sup 3+} nanophosphors showed blue-shift as compared to bulk. • Effect of H{sub 3}BO{sub 3} on the mechanoluminescence of SrAl{sub 2}O{sub 4}:Dy{sup 3+} was studied.

  16. The minimum measurable dose of CaF{sub 2}:Dy measured via an improved heating profile with an automatic 6600 thermoluminescent detector

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shachar, B; Weinstein, M; German, U [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    One of the advantages of the thermoluminescent method is its ability to measure low doses, which is useful in environmental dosimetry, as well as in archaeology. The CaF{sub 2}:Dy (Crown as TLD-200), has a sensitivity of 10-30 times greater than the sensitivity of TLD-100, when irradiated by Cs-137. In the present work we evaluated the TL-dose response of CaF{sub 2}:Dy, by using an improved heating profile which is giving the main glow peak alone. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses (MMD) were derived. The MMD were calculated by taking 3 times the standard deviation of the unirradiated chips. The results of the TL-dose response, as well as file fee calculated MMD by taxing 3 times the standard deviation of unirradiated chips, measured by file new 6600 automatic thermoluminescent detector, are presented in this work. We received a MMD of about 0.01 mGy (1 mrad), an improvement of a factor of 2.5 relatively to the integral light response evaluation using the standard heating profile (authors).

  17. Dosimetric characteristics of a TLD dosemeter with extremities

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Lien V, R.

    1999-01-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm 3 covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  18. Dosimetry Measurements around the Angiography Units Using Thermoluminescence Detectors (TLD)

    International Nuclear Information System (INIS)

    Salah El-den, T.; Shahein, A.Y.; Gomaa, M.A.

    2008-01-01

    The thermoluminescent dosimeters (TLDs) are widely used not only in the field of personnel monitoring (dosimetry) service for ionizing radiation to medical, and research communities, but also for measurements of X-rays emitted from different angiography's unit. Measurements ionizing radiation around the bed area during cardiac catheterization procedures using X-rays was measured. TLD Badges used to determine the annual effective doses, the safe distance for the staff to minimize radiation exposure and the effectiveness of shield and used leaded apron. The results indicated that annual effective dose for by angiography cardiac Catheterization room may exceed the limits

  19. Microstructures and mechanical properties of Mg–Zn–Zr–Dy ...

    Indian Academy of Sciences (India)

    Microstructures and phase compositions of as-cast and extruded ZK60–Dy ( = 0–5) alloys were analysed by optical microscope, scanning electron microscope, X-ray diffraction and differential scanning calorimetry. Meanwhile, the tensile mechanical property was tested.With increasing Dy content, Mg–Zn–Dy new phase ...

  20. NRC TLD Direct Radiation Monitoring Network. Progress report, January-June 1981

    International Nuclear Information System (INIS)

    1982-04-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of 55 NRC-licensed facility sites throughout the country for the first half of 1981. The program objectives, scope, and methodology are given. The TLD system, dosimeter location, data processing scheme, and quality assurance program are outlined

  1. A TLD dose algorithm using artificial neural networks

    International Nuclear Information System (INIS)

    Moscovitch, M.; Rotunda, J.E.; Tawil, R.A.; Rathbone, B.A.

    1995-01-01

    An artificial neural network was designed and used to develop a dose algorithm for a multi-element thermoluminescence dosimeter (TLD). The neural network architecture is based on the concept of functional links network (FLN). Neural network is an information processing method inspired by the biological nervous system. A dose algorithm based on neural networks is fundamentally different as compared to conventional algorithms, as it has the capability to learn from its own experience. The neural network algorithm is shown the expected dose values (output) associated with given responses of a multi-element dosimeter (input) many times. The algorithm, being trained that way, eventually is capable to produce its own unique solution to similar (but not exactly the same) dose calculation problems. For personal dosimetry, the output consists of the desired dose components: deep dose, shallow dose and eye dose. The input consists of the TL data obtained from the readout of a multi-element dosimeter. The neural network approach was applied to the Harshaw Type 8825 TLD, and was shown to significantly improve the performance of this dosimeter, well within the U.S. accreditation requirements for personnel dosimeters

  2. Environmental radiation monitoring of nuclear sites by thermoluminescent dosimeters (TLD)

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1978-04-01

    The measurement of environmental radiation doses around nuclear facilities requires the detection of few mrem/year. The properties of the automatic TLD-system Harshaw Mod. 2271 for such measurements have been evaluated under practical conditions and optimized techniques derived. The automatic TLD-system is based on LiF dosimeter cards with two crystals providing gamma and beta dose values. Limit of detection defined as three standard deviations of residuel dose is 1,2 mR. Automatic readout combined with electronic data evaluation are especially useful for large monitoring networks. Practical intercomparisons of this dosimeter with bulb-type CaF 2 detectors have been performed showing good agreement of both detector. Although bulb-dosimeters proved to be extremely sensitive with a limit of detection at 0,012 mR which makes them very suitable for very short exposure times, the automatic LiF system is superior in regards of man power requirement if monthly monitoring periods are sufficient. The system has been tested in practice during two international intercomparisons performed by the US Department of Energy - Health and Safety Laboratory New York and the Physikalisch Technische Bundesanstalt Braunschweig, Germany, showing excellent agreement. Furthermore a routine monitoring network consisting of 12 measurement positions around the Research Center Seibersdorf has been operated with this technique since more than two years. (author)

  3. Influences of scattering radiation in a TLD irradiation room, 2

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Suwa, Shigeo

    1985-01-01

    The influence of scattering radiation (SR) on radiation dose rate (DR) in a TLD irradiation room was assessed. A single SD from a standard TLD apparatus, i.e., an acrylic or aluminum table, was examined. The maximum DR was attained at approximately 80 cm from the radiation source. Energy spectra of SR ranged up to the energy of direct radiation beam. Circular SD at one m from the radiation source, which contributed to DR to the direct radiation beam, was almost homogeneous. SD was large near the irradiation table, and the influence of SD on DR became smaller with SD being vertically farther from the apparatus. The influence of SD on RD to the direct radiation beam became less with an increase in gamma ray energy. At one m from the radiation source, 6 - 7 % of SD contributed to DR to the direct radiation beam for 0.662 MeV of gamma ray. This figure was one half of that with NaI (Tl) scintillation detector. (Namekawa, K.)

  4. Response of TLD-100"T"M microtubes to two RQR3 quality radiation beams

    International Nuclear Information System (INIS)

    Nunes, M.G.; Villani, D.; Almeida, S.B.; Vivolo, V.; Yoriyaz, H.; Louis, G.M.J.

    2016-01-01

    The present work compares the response of TLD-100"T"M microcubes to two RQR 3 diagnostic radiology reference quality radiation beams, defined by IEC-61267 norm, aiming to evaluate the detectability of TLD-100"T"M energy dependence reported in literature within the same reference quality radiation range. TLD-100"T"M microcubes reproducibility is assessed through the response of a second set of TLD-100"T"M microcubes, evaluated in a second thermoluminescence reader, to the RQR 3 diagnostic radiology reference quality radiation beam implemented at the Laboratorio de Calibracao de Instrumentos of IPEN, Sao Paulo, SP, Brazil. The dependence of TLD-100"T"M microcubes TL response was not detectable in these conditions and the reproducibility of the measurements is 90,2%. (author)

  5. Assessment of CaSO{sub 4}:Dy and LiF:Mg,Ti thermoluminescent dosimeters performance in the dosimetry of clinical electron beams; Avaliacao do desempenho dos detectores termoluminesncetes de CaSO{sub 4}:Dy e LiF:Mg,Ti na dosimetria de feixes clinicos de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Maira Goes

    2008-07-01

    The assessment of the performance of CaS0{sub 4}:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaS0{sub 4}:Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage. (author)

  6. Phase equilibria in Dy-Cu-Al system at 500 deg C

    International Nuclear Information System (INIS)

    Kuz'ma, Yu.B.; Milyan, V.V.

    1989-01-01

    Using the methods of X-ray diffraction analysis a diagram of phase equilibria in Dy-Cu-Al system at 500 deg C is plotted. Boundaries of solid solutions on the basis of DyCu 2 , DyCu and DyAl 2 compounds are determined and homogeneity regions of ternary compounds Dy 2 (Cu, Al) 7 and Dy(CuAl) 5 are ascertained. Compounds DyCuAl 3 , Dy 4 Cu 4 Al 11 and Dy 5 Cu 6 Al 9 have been detected for the first time

  7. Brazilian two-component TLD albedo neutron individual monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Fonseca, E.S. da, E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP: 21941-972, Rio de Janeiro, RJ (Brazil)

    2010-12-15

    Since 1983, Instituto de Radioprotecao e Dosimetria, Brazil, uses a TLD one-component albedo neutron monitor, which has a single different calibration factor specifically for each installation type. In order to improve its energy response, a two-component albedo monitor was developed, which measure the thermal neutron component besides the albedo one. The two-component monitor has been calibrated in reference neutron fields: thermal, five accelerator-produced monoenergetic beams (70, 144, 565, 1200 and 5000 keV) and five radionuclide sources ({sup 252}Cf, {sup 252}Cf(D{sub 2}O), {sup 241}Am-Be, {sup 241}Am-B and {sup 238}Pu-Be) at several distances. Since January 2008, mainly Brazilian workers who handle neutron sources at different distances and moderation, such as in well logging and calibration facilities are using it routinely.

  8. Performance analysis of the TNO TLD individual monitoring service

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Julius, H.W.

    1990-01-01

    The purpose of this study was to analyse the performance and to establish the lowest detectable occupational dose (LDOD) of the TNO TL dosemeter, in use for large scale routine individual monitoring since 1983. The TNO individual monitoring service uses three TLD reader systems and over 45000 TL dosemeters, designed to measure H s (0.07) and H p (10). Each reader system is normalised daily and each individual dosemeter is calibrated every ten readout cycles. The performance of the service is monitored by a double blind experimental set-up. A series of 10 routine dosemeters is issued every fortnight, mailed, exposed by staff not involved in the monitoring service, sent back and evaluated. The conclusion of this study is that the lowest detectable occupational dose is less than 0.04 mSv and that the integrated dose at the level of the annual dose limit is measured within 2%. (author)

  9. Analysis of uncertainties in the IAEA/WHO TLD postal dose audit system

    Energy Technology Data Exchange (ETDEWEB)

    Izewska, J. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)], E-mail: j.izewska@iaea.org; Hultqvist, M. [Department of Medical Radiation Physics, Karolinska Institute, Stockholm University, Stockholm (Sweden); Bera, P. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)

    2008-02-15

    The International Atomic Energy Agency (IAEA) and the World Health Organisation (WHO) operate the IAEA/WHO TLD postal dose audit programme. Thermoluminescence dosimeters (TLDs) are used as transfer devices in this programme. In the present work the uncertainties in the dose determination from TLD measurements have been evaluated. The analysis of uncertainties comprises uncertainties in the calibration coefficient of the TLD system and uncertainties in factors correcting for dose response non-linearity, fading of TL signal, energy response and influence of TLD holder. The individual uncertainties have been combined to estimate the total uncertainty in the dose evaluated from TLD measurements. The combined relative standard uncertainty in the dose determined from TLD measurements has been estimated to be 1.2% for irradiations with Co-60 {gamma}-rays and 1.6% for irradiations with high-energy X-rays. Results from irradiations by the Bureau international des poids et mesures (BIPM), Primary Standard Dosimetry Laboratories (PSDLs) and Secondary Standards Dosimetry Laboratories (SSDLs) compare favourably with the estimated uncertainties, whereas TLD results of radiotherapy centres show higher standard deviations than those derived theoretically.

  10. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments

    International Nuclear Information System (INIS)

    Romero, A.M.; Saez, J.C.

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  11. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments

    International Nuclear Information System (INIS)

    Romero, A. M.; Saez, J. C

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  12. Availability of S from superphosphate and CaSO4.2H2O to alfafa (Medicago sativa L. Pers.) using tracer technique

    International Nuclear Information System (INIS)

    Aulakh, M.S.; Dev, G.

    1977-01-01

    The availability of S from superphosphate to alfalfa was evaluated and compared with CaSO 4 .2H 2 O (as the standard) in the greenhouse on a S deficient arid brown soil at 4 levels of applied S (0, 5, 10 and 20 ppm). A basal dose of N, P, K and Ca was made and the effect was studied for two growth stages (80 and 120 days). Sulphur application significantly increased the yield of dry matter, S content and total S removal in both the cuttings individually and for total harvest. In this effect, superphosphate was found to be more efficient. The radio-assay data confirmed that with graded levels of applied S, the fraction of fertilizer S in the plant increased without much off-setting S fraction from the native soil source, the effect being more with superphosphate treatment compared to CaSO 4 .2H 2 O. Phosphorus concentration in alfalfa decreased significantly with increasing level of applied S. The first cutting of alfalfa recorded higher P content in superphosphate series and in the second cutting, this difference between the two sources decreased. At optimum level of 20 ppm S, superphosphate was more effective than CaSO 4 .2H 2 O in narrowing N:S ratio to 11:1 and increasing S:P ratio to more than 1:1. (author)

  13. Transition rates in {sup 161}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Berg, V; Malmskog, S G

    1969-06-15

    The decay of {sup 161}Tb has been studied using a high resolution Ge(Li)-detector. Five new transitions were observed and fitted into the earlier proposed decay scheme. The half-life of the 131.8 keV level in {sup 161}Dy was determined in a delayed coincidence measurement to be 145 {+-} 15 psec. The low level scheme in {sup 161}Dy is discussed within a quasi-particle model allowing for Coriolis mixing. Special attention is given to the strongly retarded, K-allowed 131.8 keV E1 transition with a retardation factor F{sub W} > 1.5 x 10{sup 8}.

  14. Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schwahofer, Andrea [Vivantes Clinic Neukoelln, Berlin (Germany). Dept. of Radiation Therapy; German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy; Feist, Harald [Munich Univ. (Germany). Dept. of Radiation Therapy; Georg, Holger [PTW Freiburg (Germany). Calibration Lab.; Haering, Peter; Schlegel, Wolfgang [German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy

    2017-05-01

    The aim of this study has been the experimental determination of the energy dependent dose-to-water response of TLD600 and TLD700 thermoluminescent detectors (Harshaw) in X-ray beams with mean photon energies from about 20 to 200 keV in comparison with {sup 60}Co gamma rays and 6 MV X-rays. Experiments were carried out in collaboration with the German secondary standard laboratory PTW Freiburg. The energy dependent relative responses of TLD600 and TLD700 thermoluminescence detectors were determined at radiation qualities between 30 kV{sub p} and 280 kV{sub p}. The overall uncertainty of the measured values was characterized by standard deviations varying from 1.2 to 3%. The present results agree with previous studies on the energy dependent dose-to-water response of TLD100. As an application example, the results were used to measure doses associated with X-ray imaging in image-guided radiotherapy.

  15. Room-temperature ferromagnetism in Dy films doped with Ni

    Energy Technology Data Exchange (ETDEWEB)

    Edelman, I. [Kirensky Institute of Physics, Siberian Division, Russian Academy of Sciences, Akademgorodok, Krasnoyarsk 660036 (Russian Federation)], E-mail: ise@iph.krasn.ru; Ovchinnikov, S. [Kirensky Institute of Physics, Siberian Division, Russian Academy of Sciences, Akademgorodok, Krasnoyarsk 660036 (Russian Federation); Siberian Federal University, Av. Svobodnyi 71, Krasnoyarsk 660074 (Russian Federation); Markov, V.; Kosyrev, N.; Seredkin, V.; Khudjakov, A.; Bondarenko, G. [Kirensky Institute of Physics, Siberian Division, Russian Academy of Sciences, Akademgorodok, Krasnoyarsk 660036 (Russian Federation); Kesler, V. [Institute of Semiconductor Physics, Siberian Division, Russian Academy of Sciences, Av. Akademika Lavrent' eva 13, Novosibirsk 630090 (Russian Federation)

    2008-09-01

    Temperature, magnetic field and spectral dependences of magneto-optical effects (MOEs) in bi-layer films Dy{sub (1-x)}Ni{sub x}-Ni and Dy{sub (1-x)}(NiFe){sub x}-NiFe were investigated, x changes from 0 to 0.06. Peculiar behavior of the MOEs was revealed at temperatures essentially exceeding the Curie temperature of bulk Dy which is explained by the magnetic ordering of the Dy layer containing Ni under the action of two factors: Ni impurities distributed homogeneously over the whole Dy layer and atomic contact of this layer with continues Ni layer. The mechanism of the magnetic ordering is suggested to be associated with the change of the density of states of the alloy Dy{sub (1-x)}Ni{sub x} owing to hybridization with narrow peaks near the Fermi level character for Ni.

  16. Room-temperature ferromagnetism in Dy films doped with Ni

    International Nuclear Information System (INIS)

    Edelman, I.; Ovchinnikov, S.; Markov, V.; Kosyrev, N.; Seredkin, V.; Khudjakov, A.; Bondarenko, G.; Kesler, V.

    2008-01-01

    Temperature, magnetic field and spectral dependences of magneto-optical effects (MOEs) in bi-layer films Dy (1-x) Ni x -Ni and Dy (1-x) (NiFe) x -NiFe were investigated, x changes from 0 to 0.06. Peculiar behavior of the MOEs was revealed at temperatures essentially exceeding the Curie temperature of bulk Dy which is explained by the magnetic ordering of the Dy layer containing Ni under the action of two factors: Ni impurities distributed homogeneously over the whole Dy layer and atomic contact of this layer with continues Ni layer. The mechanism of the magnetic ordering is suggested to be associated with the change of the density of states of the alloy Dy (1-x) Ni x owing to hybridization with narrow peaks near the Fermi level character for Ni

  17. Magnetostriction of Tb-Dy-Fe crystals

    International Nuclear Information System (INIS)

    Mei Wu; Okane, T.; Umeda, T.

    1998-01-01

    left angle 111 right angle -oriented twin free Tb-Dy-Fe single crystals, left angle 112 right angle - and left angle 110 right angle -oriented twinned ''single'' Tb-Dy-Fe crystals were prepared using floating zone melting crystal growth methods. Magnetostrictive performances of the crystals were investigated. Better low-field properties were observed in the left angle 110 right angle twinned crystals than in the left angle 112 right angle crystals. The highest properties were achieved in the left angle 111 right angle twin free single crystals. Even though there were still oxidized particles in the present left angle 111 right angle single crystals, a large magnetostrictive jump of 1700 ppm and a very low saturation magnetic field of 500 Oe were obtained. To understand magnetization and magnetostriction of different Tb-Dy-Fe crystals, theoretical modeling was carried out based on a simplified domain rotation model. Magnetization moment rotation paths of different domains were simulated and hence the resultant magnetostriction was obtained, which could adequately account for the experimental results of different crystals. The limitation of the domain rotation model was also discussed. (orig.)

  18. Electrical and magnetic transport properties of DyTiGe

    International Nuclear Information System (INIS)

    Dagula, W.; Tegus, O.; Li, X.W.; Zhang, L.; Brueck, E.; Boer, F.R. de; Buschow, K.H.J.

    2004-01-01

    Electrical resistivity and magnetoresistance of DyTiGe were investigated as a function of temperature and magnetic field. DyTiGe is an antiferromagnet with Neel temperature, T N , of 180 K. The electrical resistivity has an anomaly around T N . Below T N , the magnetoresistance of DyTiGe abruptly changes at a critical field. At 5 K, we observe a magnetoresistance reduction of about 20%

  19. Vivo dosimetry using TLD detectors in prostate seed implants of I-125: preliminary results

    International Nuclear Information System (INIS)

    Sanchez-Reyes, A.; Pedro, A.; Bassas, P.; Duch, M. A.; Cros, M.; Mane, S.

    2011-01-01

    We present preliminary results of a new in vivo dosimetry technique that could allow to know immediately after implantation of the prostate if the dose distribution determined by the scheduler is similar to the actual dose measured with TLD detectors.

  20. NRC [Nuclear Regulatory Commission] TLD [thermoluminescent dosimeter] direct radiation monitoring network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1989-09-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the second quarter of 1989

  1. NRC TLD [thermoluminescent dosimeter] Direct Radiation Monitoring Network: Progress report, January-March 1988

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1988-06-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the first quarter of 1988

  2. Postal TLD audits in radiotherapy in the Czech Republic: current status, experience and potential

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Kapucianova, Michaela; Dufek, Vladimir

    2014-01-01

    The paper deals with practice and performance of postal TLD audits in radiotherapy with emphasis on the possibilities of application of the advanced versions that were developed following up technological progress in radiotherapy. The new methodologies of the TLD audit are focused specifically on up-to-date linear accelerators, equipped with multileaf collimators, and modern treatment planning systems. The dose is checked by the TLD not only for reference conditions but also in conditions of radiation fields influenced by presence of inhomogeneities in the irradiated volume. As regards small radiation fields, the check also includes dose profile verification using gafchromic films. The methodologies were tested within pilot studies performed in collaboration with some Czech radiotherapy centers. The results and experience gave evidence of the usefulness and appropriateness of the new TLD audit methodologies. (orig.)

  3. NRC TLD direct radiation monitoring network: Progress report, April--June 1988

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1988-09-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the second quarter of 1988

  4. Defective muscle basement membrane and lack of M-laminin in the dystrophic dy/dy mouse

    DEFF Research Database (Denmark)

    Xu, H; Christmas, P; Wu, X R

    1994-01-01

    -linked Duchenne and Becker muscular dystrophies. We have examined M-laminin expression in mice with autosomal recessive muscular dystrophy caused by the mutation dy. The heavy chain of M-laminin was undetectable in skeletal muscle, heart muscle, and peripheral nerve by immunofluorescence and immunoblotting......M-laminin is a major member of the laminin family of basement membrane proteins. It is prominently expressed in striated muscle and peripheral nerve. M-laminin is deficient in patients with the autosomal recessive Fukuyama congenital muscular dystrophy but is normal in patients with the sex...... tissue from dy/dy mice, suggesting that M-laminin heavy-chain mRNA may be produced at very low levels or is unstable. Information about the chromosomal localization of the M heavy-chain in human and mouse suggests that a mutation in the M-chain gene causes the muscular dystrophy in dy/dy mice. The dy...

  5. Therapeutical radiopharmaceuticals based In vivo generator system [166 Dy] Dy/166 Ho

    International Nuclear Information System (INIS)

    Ferro F, G.; Garcia S, L.; Monroy G, F.; Tendilla, J.I.; Pedraza L, M.; Murphy, C.A. de

    2002-01-01

    At the idea to administer to a patient a molecule containing in it structure a father radionuclide, with a half life enough large which allows to the radiolabelled molecule to take up position specifically in a white tissue and decaying In vivo to the daughter radionuclide with properties potentially therapeutic, it is known as In vivo generator system. In this work the preparation and the preliminary dosimetric valuations of radiopharmaceuticals based In vivo generator system 166 Dy Dy/ 166 Ho for applications in radioimmunotherapy, in the treatment of the rheumatoid arthritis and in the bone marrow ablation (m.o.) for candidates patients to bone marrow transplant are presented. (Author)

  6. Methods on TLD management be applicable in nuclear power plantsunder the multi-reactor operational mode

    International Nuclear Information System (INIS)

    Luo Huiyong; Wen Qinghua; Li Ruirong; Yu Enjian

    2006-01-01

    This paper discusses the methods on management of TLD dosimeters adopted in DNMC and other NPPs, analyzes and evaluates their both defects and advantages. Facing the coming of the multi-reactor operational mode applied in NPPs, a new method intelligent management mode is put forward, this optimized method not only assures the accuracy of TLD's measurement but also reduces the cost of production and improves the efficiency of management greatly. (authors)

  7. Indoor gamma dose measurements in Gudalore (India) using TLD

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R.; Selvasekarapandian, S. E-mail: spandian@bharathi.ernet.in; Mugunthamanikandan, N.; Raghunath, V.M

    2002-06-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO{sub 4} : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h{sup -1} and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 {mu}Sv y{sup -1}, for the inhabitants of mud houses to 1406.3 {mu}Sv y{sup -1}, for those living in terrace houses made of cement and brick.

  8. TLD system for the monitoring of the environmental radioactivity

    International Nuclear Information System (INIS)

    Stochioiu, Ana; Sahagia, Maria; Tudor, Ion

    2008-01-01

    The paper presents a high sensitivity TLD system, designed for the survey of the environmental radioactivity. It is based on the use of TL detectors type LiF:Mg, Cu, P, commercially known as GR-200A. The dosimeter designed in our Institute, contains 3 detectors, and the measurement value is calculated as the arithmetic mean. A very sensitive, TL Reader, READER ANALYSER RA'94 was chosen and an optimal thermal cycle was designed, such as to enhance the measurement performances. For each placement, a set of 3 dosemeters is used, and survey intervals from 1 to 100 days, depending on the radioactivity level and reporting requirements, are selected. The technical characteristics of the system were determined by exposing the dosimeters in reference X and gamma radiation fields, such as required by the IEC standard 61066:iun.2006 'Thermoluminescence dosimetry systems for personal and environmental monitoring'. The main technical parameters are of highest quality and recommend it for use in the survey of the environmental radioactivity, at the level of ambient dose equivalent rate, due to normal natural radioactivity, in open areas. The paper describes the method of characterisation and measurement results, as well as their relevance. (author)

  9. The application of artificial neural networks to TLD dose algorithm

    International Nuclear Information System (INIS)

    Moscovitch, M.

    1997-01-01

    We review the application of feed forward neural networks to multi element thermoluminescence dosimetry (TLD) dose algorithm development. A Neural Network is an information processing method inspired by the biological nervous system. A dose algorithm based on a neural network is a fundamentally different approach from conventional algorithms, as it has the capability to learn from its own experience. The neural network algorithm is shown the expected dose values (output) associated with a given response of a multi-element dosimeter (input) many times.The algorithm, being trained that way, eventually is able to produce its own unique solution to similar (but not exactly the same) dose calculation problems. For personnel dosimetry, the output consists of the desired dose components: deep dose, shallow dose, and eye dose. The input consists of the TL data obtained from the readout of a multi-element dosimeter. For this application, a neural network architecture was developed based on the concept of functional links network (FLN). The FLN concept allowed an increase in the dimensionality of the input space and construction of a neural network without any hidden layers. This simplifies the problem and results in a relatively simple and reliable dose calculation algorithm. Overall, the neural network dose algorithm approach has been shown to significantly improve the precision and accuracy of dose calculations. (authors)

  10. TLD DRD dose discrepancy: role of beta radiation fields

    International Nuclear Information System (INIS)

    Munish Kumar; Pradhan, S.M.; Bihari, R.R.; Bakshi, A.K.; Chougaonkar, M.P.; Babu, D.A.R.; Gupta, Anil

    2014-01-01

    Ionization chamber based direct reading/pocket dosimeters (DRDs), are used along with the legal dosimeters (thermoluminescent dosimeters-TLDs) for day to day monitoring and control of radiation doses received by radiation workers. The DRDs are routinely used along with the passive dosimeters (TLDs) in nuclear industry at different radiation installations where radiation levels could vary significantly and the possibility of receiving doses beyond investigation levels by radiation workers is not ruled out. Recently, recommendations for dealing with discrepancies between personal dosimeter systems used in parallel were issued by ISO. The present study was performed to measure the response of ionization chamber based pocket dosimeters to various beta sources having energy (E max ) ranging from 0.224 MeV-3.54 MeV. It is expected that the above study will be useful in resolving the disparity between TLD and DRD doses at those radiation installations where radiation workers are likely to be exposed simultaneously from photons and beta particles

  11. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  12. Use of MCNP to compare the response of dose deposited in the TLD 100, TLD 600 and TLD 700 in radiation fields due to {sup 60}Co and {sup 241}AmBe source; Uso do MCNP para comparacao das respostas de dose depositada nos TLD 100, TLD 600 e TLD 700 em campos de irradiacao devido a fontes de {sup 60}Co e {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    The successes of Boron Neutron Capture Therapy (BNCT) depend on the ability to deliver an adequate irradiation field to the target cells. Neutron beams used in BNCT are mostly driven from reactors and therefore, not only have a neutron energy range which far exceeds the thermal region but also do have a great gamma component. Beam characterization and dosimetry are consequently one of the essential procedures to be overcome to properly apply this technique. One of the methods currently used in mixed field (field containing both neutron and gamma) characterization, lies on the use of a pair of detectors with distinct responses to each beam component. But this technique needs to be better understood of how each thermoluminescent dosimeter (TLD) behaves in a mixed field or in a pure field. This work presents the results of a set of simulations performed in order to analyze the response of three ordinary types of TLDs - TLD 100, TLD 600 and TLD 700 - submitted to different irradiation fields from a Cobalt source and an Americium-Beryllium source inside a paraffin disk. And is also a possible method for performing the selection and calibration of theses TLDs. (author)

  13. High-spin structure of neutron-rich Dy isotopes

    Indian Academy of Sciences (India)

    Neutron-rich Dy isotopes; high-spin states; g-factors; cranked HFB theory. ... for 164Dy marking a clear separation in the behaviour as a function of neutron ... cipal x-axis as the cranking axis) in this mass region we have planned to make a sys-.

  14. Effect of separated layer thickness on magnetoresistance and magnetic properties of Co/Dy/Co and Ni/Dy/Ni film systems

    Science.gov (United States)

    Shabelnyk, T. M.; Shutylieva, O. V.; Vorobiov, S. I.; Pazukha, I. M.; Chornous, A. M.

    2018-01-01

    Co(5 nm)/Dy(tDy)/Co(20 nm)/S and Ni(5 nm)/Dy(tDy)/Ni(20 nm)/S trilayer films are prepared by electron-beam sputtering to investigate the influence of dysprosium layer thickness (tDy) and thermal annealing on the crystal structure, magnetoresistance (MR) and magnetic properties of thin films. The thickness of Dy layer changed in the range from 1 nm to 20 nm. The samples annealed for 20 min at 700 K. Electron diffraction patterns reveal that the as-deposited and annealed systems Co/Dy/Co and Ni/Dy/Ni had fcc-Co + hcp-Dy and fcc-Ni + hcp-Dy phase state, respectively. It is also shown that at the tDy = 15 nm the transition from amorphous to crystalline structures of Dy layer is observed. An increase in the Dy layer thickness results in changes in the MR and magnetic properties of the trilayer systems. It is shown that MR is most thermally stable against annealing to 700 K at tDy = 15 nm for Co/Dy/Co as well as for Ni/Dy/Ni. For tDy = 15 nm the, value of MR for both system increases by two times compared to those of pure ferromagnetic (FM) samples. The coercivity (Bc), remanent (Mr) and saturation (Ms) magnetization of the in-plain magnetization hysteresis loops are related to the Dy layer thickness too. The coercivity depends on the FM materials type and diffusion processes at the layer boundary. Accordingly, Mr and Ms are reduced with tDy increasing before and after annealing for both trilayer systems.

  15. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities

  16. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M [Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  17. Deviations outside the acceptance limits in the IAEA/WHO TLD audits for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Vatnitsky, S.; Izewska, J.

    2002-01-01

    The main purpose of the IAEA/WHO TLD postal dose audit programme for dosimetry in radiotherapy is to provide an independent verification of the dose delivered by treatment machines in radiotherapy hospitals. The results of the TLD audit are considered acceptable if the relative deviation between the participant's stated dose and the TLD determined dose is within ±5%. The goal of this note is to draw the attention of participants of the TLD programme to some of the common reasons for deviations outside the acceptance limits. Armed with this knowledge, other participants may avoid similar problems in the future. The analysis of deviations presented here is based on the results of TLD audits of the calibration of approximately 1000 Co-60 beams and 600 high-energy X-ray beams performed in the period 1996-2001. A total of 259 deviations outside the ±5% limits have been detected, including 204 deviations for Co-60 beams (20% of all Co-60 beams checked) and 55 for high-energy X-ray beams (10% of all X-ray beams checked). It is worth mentioning that the percentage of large deviations (beyond 10%) is also higher for Co-60 beams than for high-energy X-ray beams. Some problems may be caused by obsolete dosimetry equipment or poor treatment machine conditions. Other problems may be due to insufficient training of staff working in radiotherapy. The clinical relevance of severe TLD deviations detected in the audit programme was confirmed in many cases, but, fortunately, not all-poor dosimetric results reflect deficiencies in the calibration of clinical beams or machine faults. Sometime it happens, that the TLDs are irradiated with an incorrect dose due to misunderstanding of the instructions on how to perform the TLD irradiation. Such dosimetry errors would have no direct impact on actual dose delivered to a patient

  18. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares, Centro de Engenharia Nuclear / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rodrigues F, M. A. [Universidade Estadual Paulista, Faculdade de Medicina de Botucatu, Departamento de Dermatologia e Radioterapia, Av. Prof. Montenegro s/n, Rubiao Junior, 18601-970 Botucatu (Brazil); Vivolo, V., E-mail: chancez@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with {sup 7}Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  19. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    International Nuclear Information System (INIS)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H.; Rodrigues F, M. A.; Vivolo, V.

    2014-08-01

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with 7 Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  20. TLD Intercomparison in accelerators for radiotherapy in three Latin american countries; Intercomparacion TLD en aceleradores para radioterapia en tres paises latinoamericanos

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Azorin N, J.; Perez, M.A.; Picon, C.; Castellanos, E.; Plazas, M.C.; Murcia, G.; Archundia, L. [Depto. El Hombre y su Ambiente. Universidad Autonoma Metropolitana, Calz. Del Hueso 1100, 04960 Mexico D.F. (Mexico)

    1998-12-31

    In Radiotherapy one of the objectives is to establish and to give follow up to quality assurance programs which make sure that the doses administered to the patients with cancer are a high probability of a success in external radiation. Likewise, one of the present preoccupations of the United Nations Agencies as well as the International Atomic Energy Agency and the Pan-American Health Organization is the optimal employment of the radiations in the treatment of cancer patients since the administered dose in Radiotherapy suffers considerable variations by the lack of quality assurance programs. The use of Electron linear accelerators requires a program of quality assurance that includes expert personnel, equipment and adequate facilities. The more used methodology for the dosimetry calibration and characterization of X-ray beams and high energy electrons for radiotherapy use is using a ionization chamber dosemeter calibrated in a regional secondary standardization laboratory. However, to establish and give follow up to the quality assurance programs it is necessary the dosimetric intercomparison through TLD. In this study it was designed plastic phantoms with TLD crystals and it was made its characterization to realize an absorbed dose analysis in the crystals exposed at X-ray beams 6 MV and high energy electrons 10 and 12 MeV to standardize the dosimetric procedures and proceeding to realize an International Pilot intercomparison of absorbed doses in TLD crystals in three Latin American countries: Mexico, Peru and Colombia with the participation of accelerators of five different institutions. The found results show that the majority of the measured doses with TLD in the different accelerators were in the 0.95-1.05 range though it had two cases outside of this range. The use of the phantoms with TLD crystals shows that they are of excellent aid to make analysis of the doses administered to the patients and an intercomparison of results to standardize procedures at

  1. A method to minimise the fading effects of LiF:Mg,Ti (TLD-600 and TLD-700) using a pre-heat technique.

    Science.gov (United States)

    Lee, YoungJu; Won, Yuho; Kang, Kidoo

    2015-04-01

    Passive integrating dosemeters [thermoluminescent dosimeter (TLD) and optically stimulated luminescence (OSL)] are the only legally permitted individual dosemeters for occupational external radiation exposure monitoring in Korea. Also its maximum issuing cycle does not exceed 3 months, and the Korean regulations require personal dosemeters for official assessment of external radiation exposure to be issued by an approved or rather an accredited dosimetry service according to ISO/IEC 17025. KHNP (Korea Hydro & Nuclear Power, LTD), a unique operating company of nuclear power plants (NPPs) in Korea, currently has a plan to extend a TLD issuing cycle from 1 to 3 months under the authors' fading error criteria, ±10%. The authors have performed a feasibility study that minimises post-irradiation fading effects within their maximum reading cycle employing pre-heating technique. They repeatedly performed irradiation/reading a bare TLD chip to determine optimum pre-heating conditions by analysing each glow curve. The optimum reading conditions within the maximum reading cycle of 3 months were decided: a pre-heating temperature of 165°C, a pre-heating time of 9 s, a heating rate of 25°C s(-1), a reading temperature of 300°C and an acquisition time of 10 s. The fading result of TLD-600 and TLD-700 carried by newly developed time temperature profile (TTP) showed a much smaller fading effect than that of current TTP. The result showed that the fading error due to a developed TTP resulted in a ∼5% signal loss, whereas a current TTP caused a ∼15% loss. The authors also carried out a legal performance test on newly developed TTP to confirm its possibility as an official dosemeter. The legal performance tests that applied the developed TTP satisfied the criteria for all the test categories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. IAEA/ WHO TLD postal dose intercomparison results in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Bhuiyan, N.U.; Rahman, S.

    2001-01-01

    Full text: For the accurate delivery of prescribed dose to the patients, high precision and accuracy in radiation dosimetry is required. The hospital/medical physicist is responsible for the accurate delivery of whole planned radiation doses to the patients prescribed by the radio therapist. The proper delivery of radiation doses depends upon the accurate output measurements of doses from the therapy machines. In Bangladesh, only six 60 Co units and five deep therapy machines are in use. Some more are expected to be installed soon. Still in 2001, none of the Government radiotherapy centers in Bangladesh was properly equipped with medical physicists as well as radiotherapy dosimetry equipment. Bangladesh Atomic Energy Commission (BAEC) is responsible for radiation safety in Bangladesh and BAEC has assigned Secondary Standard Dosimetry Laboratory (SSDL) of Bangladesh for providing dosimetry calibration to all radiotherapy centers in Bangladesh. The output measurements of therapy machines are performed once in a year by SSDL and the results are compared by participating in the annual TLD postal dose intercomparison program organized by IAEA/WHO SSDL Network. The absorbed dose to water is determined using IAEA dosimetry protocol (TRS 277 and 381) and water phantom of size 30 x 30 x 30 cm 3 , The measurements of SSDL are traceable to NPL of UK. The accuracy achieved in SSDL, Bangladesh has been found better than ± 3.5%, which is within the prescribed limit of dosimetry standard of IAEA. The methodology of output dose measurements in different radiotherapy centers in Bangladesh is described along with the IAEA/WHO intercomparison results

  3. Performance test of a portable TLD system for accidental doses

    International Nuclear Information System (INIS)

    Mihelic, M.; Stuhec, M.; Mitic, D.; Vekic, B.; Miljanic, S.; Ban, R.

    2005-01-01

    Full text: A portable TLD measuring system was constructed at the J. Stefan Institute many years ago, motivated by the thread of a catastrophic nuclear event. It was designed for fast measurements in accidental dosimetry mainly for military and civil protection use. The system consists of a robust portable measuring unit built for measurements in field conditions, sized about 40 cm in diameter and weighting 5 kg. Dosimeters are based on CaF 2 :Mn ceramic tablets closed in water resistant plastic housings. In original design producer assured measuring range from cGy to kGy. Specially designed energy compensating filters are used to satisfy requirements for energy response from 0,1 to 3 MeV. Stability of readings is maintained with the temperature stabilized light source. Measuring time for manually driven heating-reading cycle of one dosimeter is about 30 sec. Many systems of the type with sets of dosimeters were stored unused for some years in depositories of different institutions. Modernization of equipment in last years raised questions of applicability of such measurement systems for contemporary needs. The system was thus tested in a secondary standards dosimetry laboratory for compliance with up to date requirements for accidental individual monitoring. Dosimeter characteristics as repeatability, linearity and directional response were of particular interest. As a result of the tests, technical improvements are suggested to extent systems measuring capabilities in order to meet new standards. Possibilities of its use in different fields of dosimetry are discussed, where quick in field measurements of high doses is required as for example in medicine or in civil protection motivated by the new threads of terrorist attacks. (author)

  4. Muzeum módy - Tokyo 2010

    OpenAIRE

    Kráľová, Zuzana

    2010-01-01

    navrhovaný objekt je múzeum módy pre mesto Tokio. Múzeum sa bude nachádzať na pulzujúcej tepne tokijského módneho diania. Navrhovaná budova presahuje 100m výšky a jej zbierky mapujú vývoj svetovej módy 20.storčia. Taktiež je dejiskom konania živých módnych show a priestorom pre prezentáciu tvorby mladých módnych tvorcov. Samotné artefakty zbierky sú vystavované jednotným systémom - zavesením. visiace figuríny prechádzajú kontinuálne celým výstavným priestorom, návštevníkovi je umožnený pohyb ...

  5. COLOR STABILITY OF NATURALLY DYED DENIM FABRICS

    Directory of Open Access Journals (Sweden)

    SUBTIRICA Adriana-Ioana

    2014-05-01

    Full Text Available The desire to colour textiles is as old as spinning and weaving. Natural dyes have been used since thousands of years for their long endurance, soft and elegant colours. But the invention of synthetic dyes has limited the application of natural dyes. The health hazards associated with the use of synthetic dyes and also the increased environmental awareness have revived the use of natural dyes during the recent years. The major performance characteristic of a dye is its ability to maintain the colour in normal use and is known as colorfastness. The study provides information regarding colour fastness properties of naturally dyed denim fabrics. Three vegetable materials were used for dyeing denim fabrics: Punica granatum (bark powder, Indigofera tinctoria (leave powder and Juglans regia (walnut dried shells. The results of the study indicated that using Walnut shells and Punica granatum deeper and more stable shades of colors are obtained in comparison with Indigofera Tinctoria dyed denim samples. All samples highlight a change in color in the sense of fading which has occurred to the highest extent when exposed to artificial light and washing. When tested against water, alkaline and acid perspiration, it is noticed that better results are obtained, and color change appear in a smaller extent.

  6. Preparation of CaF{sub 2}:Dy chips as thermoluminescent dosimeters for environmental measurements using a Harshaw 2080 TL picoprocessor

    Energy Technology Data Exchange (ETDEWEB)

    Matoso, Erika; Leite, Barbara Eliodora [Centro Tecnologico da Marinha em Sao Paulo (CTMSP/CEA), Ipero, SP (Brazil). Centro Experimental Aramar; Nunes, Maira Goes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work presents the necessary steps to prepare the dosimeters for application in environmental measurements. The material used was calcium fluoride doped with dysprosium (CaF{sub 2}: Dy), commercially supplied by Harshaw as TLD-200. It were carried out four initial irradiations (Co-60 source gamma - 0.8 mGy from Dosimetric Material Laboratory LMD/GMP) in a new batch of TLD-200 dosimeters to achieve a stable response and four more irradiations to separate them, according to their response range. A batch of pre-selected 197 dosimeters from 263 was used to finally obtained two batches of 99 (9.2{+-}0.7nC) and 93 (10.5{+-}0.6nC) dosimeters. A calibration curve was prepared relating the thermoluminescent response of the phosphor and the radiation exposure (0 to 600{mu}Gy), obtained by irradiation with Co-60 source of 4P geometry and measurements using a Harshaw Picoprocessor 2080 TL equipment. Repeatability of the measurements was determined for 100{mu}Gy (CV= 5.09%) and 300{mu}Gy (CV=4.18%) and the minimum detectable dose was evaluated as 2{mu}Gy. The fading was determined by irradiating the dosimeters with 0.8 mGy and reading then after 1, 5, 7, 8, 15, 29, 50, 70 and 90 days. (author)

  7. Production of thermoluminescent dosemeters based on MgB{sub 4}O{sub 7}: Dy and MgB{sub 4}O{sub 7}: Tm; Producao de dosimetros termoluminescentes a base de MgB{sub 4}O{sub 7}: Dy e MgB{sub 4}O{sub 7}: Tm

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiza Freire de; Souza, Divanizia N., E-mail: luizaf25@hotmail.com, E-mail: divanizi@ufs.br [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Programa de Pos-Graduacao em Fisica

    2013-07-01

    The thermoluminescent dosimetry (TL) is a well-established technique for the detection of ionizing radiation in hospitals, clinics, and industrial establishments where there is the need to quantify the radiation. For this practice is require the use phosphors which are sensitive to radiation. Some phosphors are already commonly used in this practice, for example, TLD-100 (LiF: Mg, Ti), CaSO{sub 4}:Tm and CaSO{sub 4}:Dy. A compound that was most recently introduced in dosimetry and has many advantageous features to detect neutrons, electrons and gamma is the magnesium tetraborate (MgB{sub 4}O{sub 7}), but the undoped material is not good for dosimetry, since signal does not show satisfactory thermoluminescence. The present work presents the analysis of the compound MgB{sub 4}O{sub 7} when doped with rare earth elements, thulium (Tm) and dysprosium (Dy). The production of MgB{sub 4}O{sub 7}: Dy and MgB{sub 4}O{sub 7}: Tm occurred under acidic conditions. Following the process of crystal growth, several tests were made on phosphors produced to verify the quality of materials as TL dosimeter. Initially, was made the identification of the crystalline phases found in the material, using the technique of X-ray diffractometry, and then were evaluated and compared the TL emission curves of the crystals with two different types of dopants, to this, the samples were irradiated with different radiation sources: {sup 137}Cs (0,66 MeV), {sup 60}Co (1.25 MeV) and X-rays (0.41 MeV) and based on the results was evaluated the energy dependence of phosphors. Another characteristic analyzed, was the decay of TL signal for the material (fading). The results show that the material can be an excellent TL dosimeter when doped with rare earth elements Dy and Tm. (author)

  8. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's [thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Busick, D.D.

    1987-03-01

    TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs., 9 figs., 1 tab

  9. The study of new calibration features in the Harshaw TLD system

    International Nuclear Information System (INIS)

    Luo, L. Z.

    2007-01-01

    The Harshaw TLD system has three key calibration procedures: the Reader, the Dosemeter and the Algorithm. These functions must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosemeter calibration, Harshaw TLD recommends a pre-fade and a post-fade of 24-48 h when calibrating the system for LiF:Mg,Ti type dosemeter. It is also recommended that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the Harshaw TLD models 6600 and 8800 operating systems. These new features are Auto Calibration, Auto QC and Auto Blank, and they give the user the ability to set up the clear-expose-read process to be performed automatically in a sequence for each dosemeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of Auto Calibration/Auto QC to the TLD operation. (authors)

  10. Characteristics of transfer of europium ions from phosphoric acid solution into the CaSO4·O.5H2O solid phase

    International Nuclear Information System (INIS)

    Berdonosova, D.G.; Burlakova, E.V.; Yasenkova, M.A.; Ivanov, L.N.; Melikhov, I.V.

    1989-01-01

    The mechanism of formation of the precipitated CaSO 4 ·0.5H 2 O phase was studied in detail; the precipitation was performed at 80 degree, equimolar solutions of Ca(H 2 PO 4 ) 2 and H 2 SO 4 in phosphoric acid of 38% concentration being used. The availability of detailed information on the mechanism of formation of CaSO 4 ·0.5H 2 O precipitates determined the choice of conditions of study of capture of rare earths. In particular, H 3 PO 4 of 38% P 2 O 5 concentration was used as the medium of formation of the calcium sulfate precipitate. Europium was chosen as the rare earth. Its behavior in the liquid and solid phases was studied by radiometric and luminescence methods. The radionuclide 152 Eu is convenient as a radioactive tracer while luminescence of europium is structure-sensitive; therefore, europium is often used in physicochemical investigations as a luminescent probe. It follows from the data that most of the europium captured by the precipitate during coagulation of the ultramicrocrystals is retained firmly by the solid phase. Therefore, in order to diminish capture of europium (and other rare earths) by the precipitate coagulation of the latter should be prevented

  11. Magnetic Properties of Dy in Pb2Sr2DyCu3O8

    International Nuclear Information System (INIS)

    Skanthakumar, S.; Soderholm, L.; Movshovich, R.

    1999-01-01

    Superconductivity can be induced at high temperatures in Pb 2 Sr 2 RCu 3 O 8 (R - rare earth) by partially doping Ca 2+ for R 3+ . In order to understand the interplay between magnetism and superconductivity, the magnetic properties of the parent compounds, Pb 2 Sr 2 RCu 3 O 8 , have been studied. The work presented here includes magnetic susceptibility and specific heat measurements on R=Dy and extends the previous studies on R=Ce, Pr, Tb, Ho and Er. Specific heat experiments suggest that the Dy ions order antiferromagnetically with an ordering temperature of 1.3K. The magnetic susceptibility data are in good agreement with the susceptibility calculated using crystal field parameters that are extrapolated from previous modeling of the R=Er and Ho analogs of this series

  12. Search for superdeformed bands in {sup 154}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Nisius, D.; Janssens, R.V.F.; Khoo, T.L. [and others

    1995-08-01

    The island of superdeformation in the vicinity of the doubly magic {sup 152}Dy yrast superdeformed (SD) band is thought to be well understood in the framework of cranked mean field calculations. In particular, the calculations suggested that in {sup 154}Dy there should be no yrast or near yrast SD minimum in the 40-60 h spin range, where SD bands in this mass region are thought to be {sup 153}Dy nucleus, it is populated. However, with the presence of five SD bands in the neighboring necessary to ascertain if the addition of one single neutron diminishes the importance of shell effects to the extent that superdeformation can no longer be sustained. In an experiment utilizing the increased resolving power of the early implementation phase of Gammasphere, the reaction {sup 122}Sn({sup 36}S,4n) at 165 MeV was employed to populate high spin states in {sup 154}Dy. In a four-day run with 36 detectors, over one billion triple and higher fold coincidence events were recorded. One new SD band was identified and was assigned to {sup 154}Dy. From comparisons with the Im{sup (2)} moments of inertia of the SD bands in {sup 152}Dy and {sup 153}Dy, a configuration based on (514)9/2{sup 2} neutrons coupled to the {sup 152}Dy SD core was proposed. One unexpected and as yet unexplained feature of this new SD band is that the transition energies are almost identical to those of an excited SD band in {sup 153}Dy. It is also worth noting that the feeding of the yrast states is similar to that achieved by the deexcitation from the ensemble of all entry states in the reaction. This observation emphasizes the statistical nature of the decay-out process. A paper reporting these results was accepted for publication.

  13. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

    Directory of Open Access Journals (Sweden)

    HosseiniAliabadi S. J.

    2015-06-01

    Full Text Available Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion: This system can be utilized in large scale environmental monitoring with a higher accuracy

  14. Investigation of LiF, Mg and Ti (TLD-100 Reproducibility

    Directory of Open Access Journals (Sweden)

    Sadeghi M.

    2015-12-01

    Full Text Available LiF, Mg and Ti cubical TLD chips (known as TLD-100 are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC were obtained 4 times by irradiating them to doses of 81 mGy (two times, 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  15. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    Science.gov (United States)

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  16. Optimization of the temperature profiles due to a nitrogen jet impinging on a TLD detector

    International Nuclear Information System (INIS)

    Cohen, I.; Bar-Kohany, T.; German, U.; Ziskind, G.

    2014-01-01

    A study was conducted to simulate the temperature profiles during readout in a typical, commercial thermo-luminescence dosimeter (TLD) chip and to optimize the readout conditions. The study makes use of a previously developed numerical model which calculates the crystal's temperature profile evolution inside a TLD crystal compound. The calculated profiles were implemented in the Randall-Wilkins equation to obtain the estimated glow curve. A number of jet temperature profiles were investigated in order to optimize the readout process. - Highlights: • The temperature profiles in a TLD chip compound were simulated. • Some non-routine heating profiles are proposed. • A better efficiency and shorter time can be obtained with these profiles. • The resulting glow curves were evaluated as well

  17. Personal neutron monitoring using TLD albedo combined with etched tracks detector

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, N.; Momose, T. [Japan Nuclear Cycle Development Institute, Ibarakiken (Japan)

    2002-07-01

    The albedo dosimetry has been carried out in personal neutron monitoring in the MOX fuel plant of JNC Tokai Works, however, it has shortcomings mainly due to the inherently poor energy response. This paper describes our efforts to overcome these difficulties in practical use of albedo dosemeters. The following four subjects are presented: (1) the neutron energy response functions of albedo TLD obtained from the mono-energetic neutron irradiation experiments and the Monte-Carlo calculations, (2) the location- dependent correction factors calculated from the response functions and neutron energy spectra measured in the workplaces, (3) the results of the international personal neutron dosimetry intercomparison program, and (4) the operational comparison program of TLD albedo and etched tracks detector worn by workers engaged in the fabrication process of the MOX fuel plant. Finally, the characteristics of the combination neutron dosemeter using TLD albedo and solid state etched track detector are summarized.

  18. Program of TLD audits for quality control in radiotherapy

    International Nuclear Information System (INIS)

    Alvarez, P.; Feld, D.; Gomez, C.; Kessler, C.; Montano, R.G.; Lindner, C.; Peretti, M.; Saravi, M.; Miguez, V.; Paidon, S.; Raslawski, E.

    1998-01-01

    Full text: It is known that a high precision in radiotherapy is essential to ensure a successful radiation treatment. To reach this goal it is necessary to detect and minimise many errors, which can be done through a periodic program of quality control, not only internal checks but also participating in external audits that attempt to control the absorbed dose delivered and detect any source of error, coming from the machine itself or from human mistakes. Under the frame of the International Quality Assurance Network for Dosimetry in Radiotherapy proposed by the International Atomic Energy Agency, a National External Audit Group (EAG) has been created in our country, composed by the Secondary Standard Dosimetry Laboratory (SSDL), 2 Medical Physics and 1 Medical Radiotherapist. The SSDL and one of the Medical Physics belong to the National Atomic Energy Agency, meanwhile the rest of the group belong to the National Pediatric Hospital P rof. J.P.Garrahan . This EAG performs external audits to Radiation Therapy Centres with a thermoluminescence system, which is checked periodically by the IAEA. The audits are performed to the 60 Co γ-ray and high energy X-ray beams that are being used for medical application in the whole country. The SSDL is the responsible of the thermoluminescence measurements; deviation of the absorbed dose determined by the TLD system from the one informed by the Responsible of the Center within the interval ± 5% are considered acceptable while deviations out of this interval require the intervention of the Medical Physic Group and the Radiotherapist in order to determine the cause of the discrepancies. In 1997, 4 audits performed in reference conditions were carried out 68 60 Co units participated in the audits, 61 of them with deviation within the acceptable interval in their first participation, meanwhile 1 got this deviation in repeated audits, after the follow up performed by the Medical Physic Group. Regarding high energy X-ray beams

  19. Audit on dose delivery by using TLD in Radiotherapy Centers in Malaysia

    International Nuclear Information System (INIS)

    Md Saion Salikin; Taiman Kadni; Husaini Salleh; Asmaliza Hashim; Hasrul Husham Hussain

    2004-01-01

    The External Audit Group (EAQ) is established and supported by IAEA. Its main objective is to audit the accuracy of dose delivery to patients in radiotherapy centres or hospitals in developing countries in IAEA member states. At MINT the operation of EAG is managed by Medical Physics Group and supported by Secondary Standard Dosimetry Laboratory (SSDL), MINT. The selected radiotherapy centers are supplied with TLD powder in capsule form, to be irradiated with the required radiation doses, by their physicists. The irradiated TLD is analysed at SSDL. The result of the audit for a few radiotherapy centres in Malaysia, is presented in brief in this paper. (Author)

  20. Automated TLD systems: what can we expect from the market today?

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1990-01-01

    The personnel monitoring service at the Austrian Research Centre Seibersdorf, which presently handles some 16,000 dosemeters per month, has been operating for more than ten years with three automated TLD systems, Harshaw model 2271. In order to renew the instrumentation an extensive evaluation and comparison of four commercially available automated systems designed to the present state-of-the-art has been carried out. The test procedures included dosimetric performance, reliability, handling speed and throughput, and additional information such as glow curve evaluation etc. The results should provide useful advice to monitoring services interested in the application of modern automated TLD systems currently on the market. (author)

  1. A microcontroller based readout unit for a smart personnel monitoring TLD badge

    International Nuclear Information System (INIS)

    Gaonkar, U.P.; Kulkarni, M.S.; Kannan, S.

    1997-01-01

    An automated TLD personnel monitoring system is under development to cope up with the requirements of personnel monitoring of rapidly growing number of radiation workers. The core of the system is a smart TLD badge incorporating a memory device and a microcontroller based readout unit for reading the memory contents of the badge. The memory is used to store personnel data including the accumulated dose data. The reader unit has a serial RS 232C interface for connection to a PC for entering/modifying data in the memory. A password protected software has also been developed in C for entering/modifying the data in the single memory. 3 figs

  2. Faraday effect in γ-Dy2S3 and c-Dy2O3 paramagnetic crystals

    International Nuclear Information System (INIS)

    Shelykh, A.I.

    1987-01-01

    Studies of spectral and temperature dependences of Faraday effect in γ-Dy 2 S 3 and C-Dy 2 O 3 paramagnetic crystals are conducted. Paramagnetism of these crystals is brought about by Dy 3+ ions. Estimation of the effect of such factors as the value of paramagnetic ion concentration, width of the forbidden band, crystallochemical composition on magnetooptical effect in the considered compounds of dysprosium is carried out on the basis of the obtained experimental data and theoretical analysis. It is shown, that the Faraday effect in the considered compounds of dysprosium as well as the value of paramagnetic moment may be regarded rather accurately in free ion approximation

  3. Injectable Shear-Thinning CaSO4/FGF-18-Incorporated Chitin-PLGA Hydrogel Enhances Bone Regeneration in Mice Cranial Bone Defect Model.

    Science.gov (United States)

    Sivashanmugam, A; Charoenlarp, Pornkawee; Deepthi, S; Rajendran, Arunkumar; Nair, Shantikumar V; Iseki, Sachiko; Jayakumar, R

    2017-12-13

    For craniofacial bone regeneration, shear-thinning injectable hydrogels are favored over conventional scaffolds because of their improved defect margin adaptability, easier handling, and ability to be injected manually into deeper tissues. The most accepted method, after autografting, is the use of recombinant human bone morphogenetic protein-2 (BMP-2); however, complications such as interindividual variations, edema, and poor cost-efficiency in supraphysiological doses have been reported. The endogenous synthesis of BMP-2 is desirable, and a molecule which induces this is fibroblast growth factor-18 (FGF-18) because it can upregulate the BMP-2 expression  by supressing noggin. We developed a chitin-poly(lactide-co-glycolide) (PLGA) composite hydrogel by regeneration chemistry and then incorporated CaSO 4 and FGF-18 for this purpose. Rheologically, a 7-fold increase in the elastic modulus was observed in the CaSO 4 -incorporated chitin-PLGA hydrogels as compared to the chitin-PLGA hydrogel. Shear-thinning Herschel-Bulkley fluid nature was observed for both hydrogels. Chitin-PLGA/CaSO 4 gel showed sustained release of FGF-18. In vitro osteogenic differentiation showed an enhanced alkaline phosphatase (ALP) expression in the FGF-18-containing chitin-PLGA/CaSO 4 gel when compared to cells alone. Further, it was confirmed by studying the expression of osteogenic genes [RUNX2, ALP, BMP-2, osteocalcin (OCN), and osteopontin (OPN)], immunofluorescence staining of BMP-2, OCN, and OPN, and alizarin red S staining. Incorporation of FGF-18 in the hydrogel increased the endothelial cell migration. Further, the regeneration potential of the prepared hydrogels was tested in vivo, and longitudinal live animal μ-CT was performed. FGF-18-loaded chitin-PLGA/CaSO 4 showed early and almost complete bone healing in comparison with chitin-PLGA/CaSO 4 , chitin-PLGA/FGF-18, chitin-PLGA, and sham control systems, as confirmed by hematoxylin and eosin and osteoid tetrachrome stainings. This shows that the CaSO 4 and FGF-18-incorporated hydrogel is a potential candidate for craniofacial bone defect regeneration.

  4. Formation of CaSO4(aq) and CaSeO4(aq) studied as a function of ionic strength and temperature by CE

    International Nuclear Information System (INIS)

    Philippini, V.; Aupiais, J.; Moulin, Ch.; Vercouter, Th.

    2009-01-01

    Ca 2+ complexation by both sulfate and selenate ligands was studied by CE. The species were observed to give a unique retention peak as a result of a fast equilibrium between the free ions and the complexes. The change in the corresponding retention time was interpreted with respect to the equilibrium constant of the complexation reaction. The results confirmed the formation of CaSO 4 (aq) and CaSeO 4 (aq) under our experimental conditions. The formation data were derived from the series of measurements carried out at about 15, 25, 35, 45 and 55 degrees C in 0.1 mol/L NaNO 3 ionic strength solutions, and in 0.5 and 1.0 mol/L NaNO 3 ionic strength solutions at 25 degrees C. Using a constant enthalpy of reaction enabled to fit all the experimental data in a 0.1 mol/L medium, leading to the thermodynamic parameters: Δ r G 0.1M (25 degrees C) = -(7.59±0.23) kJ/mol, Δ r H 0.1M = 5.57±0.80 kJ/mol, and Δ r S 0.1M (25 degrees C) = 44.0±3.0 J mol -1 K -1 for CaSO 4 (aq) and Δ r G 0.1M )(25 degrees C) = - (6.66±0.23) kJ/mol, Δ r H 0.1M = 6.45±0.73 kJ/mol, and Δ r S 0.1M (25 degrees C) = 44.0±3.0 J mol -1 K -1 for CaSeO 4 (aq). Both formation reactions were found to be endothermic and entropy driven. CaSO 4 (aq) appears to be more stable than CaSe O 4(aq) by 0.93 kJ/mol under these experimental conditions, which correlates with the difference of acidity of the anions as expected for interactions between hard acids and hard bases according to the hard and soft acids and bases theory. The effect of the ionic medium on the formation constants was successfully treated using the Specific ion Interaction Theory, leading to significantly different binary coefficients ε Na + ,SO 4 2- (0.15±0.06) mol/kg -1 and ε Na + ,SeO 4 2- -(0.26±0.10)mol/kg -1 . (authors)

  5. Neutron detection using Dy2O3 activation detectors

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Mohamed, E.J.

    1979-01-01

    The aim of the present study is to examine the usefulness of Dy 2 O 3 not only as thermal neutron activation detector but also as a fast neutron detector. For thermal neutrons, the half life of 165 Dy is measured to be (141 +- 6) min, its response to thermal neutrons is (2.18 +- 0.01) cpm/ncm -2 s -1 for a 250 mg Dy 2 O 3 pellet. For fast neutrons the Dy 2 O 3 detector is placed within a 20 cm polyethylene sphere and its response is found to be (2.2 +- 0.1) cpm/ncm -2 s -1 for 4 MeV neutrons and (2.10 +- 0.04) cpm/ncm -2 s -1 for 14 MeV neutrons. For neutron dosimetry, its response is found to be (16.7 +- 0.4) cpm per mrem h -1 . (author)

  6. Search for excited superdeformed bands in {sup 151}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Nisius, D.; Janssens, R.V.F.; Crowell, B. [and others

    1995-08-01

    Following the first report of superdeformed (SD) bands with identical transition energies in the pairs ({sup 151}Tb*,{sup 152}Dy), ({sup 150}Gd*, {sup 151}Tb) and ({sup 153}Dy*, {sup 152}Dy) (where * denotes an excited SD band), it was proposed by Nazarewicz et al. that the observations could be understood in a strong-coupling approach if pseudo SU(3) symmetry were invoked. In this model there are three limiting values of the decoupling parameter; i.e. a = 0, {plus_minus}1. In the first two cases mentioned above the pairs of bands have nearly identical transition energies and are interpreted as proton excitations involving the [200]1/2 pseudospin orbital coupled to the {sup 152}Dy core, for which the value of the decoupling parameter is calculated to be a =+1.

  7. A study of the structure of 162Dy through the (n,γ) and (n,e-) reactions

    International Nuclear Information System (INIS)

    Warner, D.D.; Shi, Z.R.; Gelletly, W.; Borner, H.G.; Hoyler, F.; Schreckenbach, K.; van Isacker, P.

    1987-01-01

    The level structure below 2 MeV in 162 Dy has been investigated using the 161 Dy(n,γ) 162 Dy and 161 Dy(n,e - ) 162 Dy reactions. The results for the positive parity excitations are discussed within the framework of an Interacting Boson Approximation (IBA-2) calculation. 7 refs., 1 fig., 1 tab

  8. Beta-delayed proton activities: 147Dy and 149Er

    International Nuclear Information System (INIS)

    Toth, K.S.; Moltz, D.M.; Schloemer, E.C.; Cable, M.D.; Avignone, F.T. III; Ellis-Akovali, Y.A.

    1984-01-01

    The present paper discusses mainly the β-delayed proton spectra of 147 Dy and of the hitherto unknown isotope, 149 Er. However, following the submittal of the abstract for this conference we have now observed delayed protons following the decay of 145 Dy. Additionally, we have identified a 0.5-s delayed-proton emitter and tentatively assign it to the new isotope, 151 Yb

  9. Effects of the size and content of protein aggregates on the rheological and structural properties of soy protein isolate emulsion gels induced by CaSO4.

    Science.gov (United States)

    Wang, Xufeng; He, Zhiyong; Zeng, Maomao; Qin, Fang; Adhikari, Benu; Chen, Jie

    2017-04-15

    The effects of the size and content of soy protein isolate (SPI) aggregates on the rheological and textural properties of CaSO 4 -induced SPI emulsion gels were investigated. Considerable differences in the rheological, water-holding, and micro-structural properties were observed. The gels with larger and/or more SPI aggregates showed substantial increase in the elastic modulus and had lower gelation temperatures. Creep data suggested that the size of the SPI aggregates contributed more to the elastic modulus, whereas the increase of aggregate content enhanced the elastic modulus and viscous component of the gels. The water-holding capacity was markedly enhanced (pemulsions and emulsion gels. Copyright © 2016. Published by Elsevier Ltd.

  10. The influence of thyroid geometry on the response of LiF and CaSO4 thermoluminescent discs to 131I and 125I irradiation

    International Nuclear Information System (INIS)

    O'Connor, M.K.; Malone, J.F.; Cullen, M.J.

    1978-01-01

    Recent work has demonstrated that LiF and CaSO 4 thermoluminescent discs may be used to monitor the effective half-life of radioiodine in the thyroid in man. To provide a firm basis for the work, the radiation field presented by model thyroids to thermoluminescent discs on the surface of a neck phantom has been examined in detail. The influence of thyroid mass, depth and lobe separation, factors which in practice are highly variable, has also been determined. The results demonstrate that the method is sufficiently sensitive to measure less than 0.5 μCi of 131 I or 125 I in the human thyroid, and that effective half-life determinations should not be influenced by minor positioning errors which may be encountered when placing thermoluminescent discs on the neck surface. (author)

  11. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M.; Dhote, Dipak S.; Deshpande, Deepak D.

    2009-01-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  12. Calibration of TLD cards to beta ray spectra of 32P

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1994-01-01

    The results of the evaluation of TLD chips are received in nC, and we need to transform these values to mGy, in order to obtain the penetrating and the non-penetrating dose. The calibration factors were determined experimentally by irradiation the TLD chips with an uranium source. Beta rays having other spectra can cause incorrect values when estimating the non-penetrating dose. If the spectrum of the beta source is known, a specific evaluation of the calibration factor can be performed. In this report, the estimation of the calibration factor for a 32 P source is presented. LiF:Ti,Mg TLD cards were irradiated calibrated source of 90 Sr/ 90 Y and 204 Tl and non-calibrated source of 32 P, in order to find the beta correction factor for the spectrum of 32 P. Calculations of the beta correction factor were performed too, by applying the Loevinger equations to the geometry of the TLD chips used in our routine measurements. The calculated values of the beta correction factors are lower than the experimental ones. When comparing the ratios, between the beta factors of 32 P and 90 Sr/ 90 Y received from the experiments and from the calculation, we found them to be constant up to ±5%. (authors) 15 refs, 2 figs, 6 tabs

  13. Development and extension of TLD audit in radiation therapy in the Czech Republic

    International Nuclear Information System (INIS)

    Valenta, J.; Ekendahl, D.

    2005-01-01

    A comprehensive and adequate quality assurance (QA) program is a crucial factor in minimizing gross errors and in reducing uncertainties caused during any of consecutive steps of radiation therapy process. Since 1997, the measuring centre of National Radiation Protection Institute in Prague (NRPI) has been performing TLD audit in external beam radiation therapy via mailed TL dosimeters, as a part of comprehensive QA program. The objective of TLD audit is to check dose delivery accuracy at radiation therapy centers and to inform the State Office for Nuclear Safety (SONS) on the situation. The flexibility of the method enables NRPI to inspect each centre at least once every two years. Compared with the EU average, situation in the Czech Republic seems to be similar. 95 % of measurements show deviation up to 5 % (97 % in the EQUAL network). Nevertheless, the acceptance level is stricter (3 %) in the Czech Republic. This is affordable because o(the small size of the country, and better ability to confirm the results promptly , if tolerance levels are exceeded. Still, 84 % of results meet the criteria of 3 %. Both basic and advanced modes of TLD audit may discover deviations in clinical dosimetry or in treatment planning for reference and non reference .conditions, although they do not provide enough data for proper interpretation of errors. The results show the importance of independent TLD audit as a flexible and operational part of the comprehensive quality assurance program. (authors)

  14. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy.

    Science.gov (United States)

    Kinhikar, Rajesh A; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M; Dhote, Dipak S; Deshpande, Deepak D

    2009-09-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  15. Environmental dosimetry system based on LiF : Mg, Ti (TLD-100)

    International Nuclear Information System (INIS)

    Saez Vergara, J.C.

    1990-01-01

    The report presents the various tests carried out to the characterize a thermoluminescence environmental dosimetry systems, using the phosphor LiF:mg,Ti (TLD-100) in chip form. The holder has been specifically designed in order to obtain simplicity in the operation and to assure correct measurements in terms of the new operational quantities in radiation protection (ICRU-1985). Some topics in TLD Environmental Monitoring are discussed (Dark Current, Reference Light, Zero Reading, Free-in-Air or Phantom Calibration, Fading Correction, Transit Dose, etc.), and the proposed solutions are exposed. The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI : N545-1975; IEC: Draft 45B-1987, ISO : DP 8034-19849. The data from an European Interlaboratory Programm (EUR-8932) have been used to evaluate the performance : the TLD System presented is among the best systems using TLD-100. The results obtained in the characterization (linearity, repeatability, detection threshold, residue, angular response, stability of stored information, etc.) show the optimum performance of this dosimetric system in its application to environmental gamma dose monitoring. Based on these results, two operational procedures have been developed for the application of this Dosimetric System, specially in Quality Assurance Monitoring Programs around Nuclear Plants in Spain. (author)

  16. Electronic stability and reproducible accuracy of HARSHAW 2000(A,B) TLD-analyzer

    International Nuclear Information System (INIS)

    Yossef, S.K.; Henaish, B.A.

    1985-01-01

    Nowadays, the thermoluminescence techniques utilizing natural materials and assorted chemical compound of various geometrical configurations are widely and popularly used on the international scale as a dose evaluation system. The main problems which are usually encounting the accuracy of the evaluated dose by means of such various dosimeter forms are the long and short term stability of the measuring system. Also this manuscript is a very essential details stated out the principle mechanisms which cause that produced TL-readers instability. As it is stated out through the different sections of this issue, it is mainly due to the interior mechanisms of the TLD measuring systems. Further more, the various detailed discussions availed through the different sections of such issue are mainly accompanied by long term experiences gained by the authors. A novel heating cycle mechanism applied to HARSHOW 2000(A and b) TLD analyzer is tested experimentally. Also long and short term stability beside the reproducibility of the TLD reader system were experimentally tested under various seasonable environmental thermal conditions. The results of experimental measurements were noted for a total duration of six months during continuous operation of the TLD reader for one year. 1 fig., 3 tab

  17. TLD Intercomparison in accelerators for radiotherapy in three Latin american countries

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez, M.A.; Picon, C.; Castellanos, E.; Plazas, M.C.; Murcia, G.; Archundia, L.

    1998-01-01

    In Radiotherapy one of the objectives is to establish and to give follow up to quality assurance programs which make sure that the doses administered to the patients with cancer are a high probability of a success in external radiation. Likewise, one of the present preoccupations of the United Nations Agencies as well as the International Atomic Energy Agency and the Pan-American Health Organization is the optimal employment of the radiations in the treatment of cancer patients since the administered dose in Radiotherapy suffers considerable variations by the lack of quality assurance programs. The use of Electron linear accelerators requires a program of quality assurance that includes expert personnel, equipment and adequate facilities. The more used methodology for the dosimetry calibration and characterization of X-ray beams and high energy electrons for radiotherapy use is using a ionization chamber dosemeter calibrated in a regional secondary standardization laboratory. However, to establish and give follow up to the quality assurance programs it is necessary the dosimetric intercomparison through TLD. In this study it was designed plastic phantoms with TLD crystals and it was made its characterization to realize an absorbed dose analysis in the crystals exposed at X-ray beams 6 MV and high energy electrons 10 and 12 MeV to standardize the dosimetric procedures and proceeding to realize an International Pilot intercomparison of absorbed doses in TLD crystals in three Latin American countries: Mexico, Peru and Colombia with the participation of accelerators of five different institutions. The found results show that the majority of the measured doses with TLD in the different accelerators were in the 0.95-1.05 range though it had two cases outside of this range. The use of the phantoms with TLD crystals shows that they are of excellent aid to make analysis of the doses administered to the patients and an intercomparison of results to standardize procedures at

  18. A Computerized QC Analysis of TLD Glow Curves for Personal Dosimetry Measurements Using Tag QC Program

    International Nuclear Information System (INIS)

    Primo, S.; Datz, H.; Dar, A.

    2014-01-01

    The External Dosimetry Lab (EDL) at the Radiation Safety Division at Soreq Nuclear Research Center (SNRC) is ISO 17025 certified and provides its services to approximately 13,000 users throughout the country from various sectors such as medical, industrial and academic. About 95% of the users are monitored monthly for X-rays, radiation using Thermoluminescence Dosimeter (TLD) cards that contain three LiF:Mg,Ti elements and the other users, who work also with thermal neutrons, use TLD cards that contain four LiF:Mg,Ti elements. All TLD cards are measured with the Thermo 8800pc reader. Suspicious TLD glow curve (GC) can cause wrong dose estimation so the EDL makes great efforts to ensure that each GC undergoes a careful QC procedure. The current QC procedure is performed manually and through a few steps using different softwares and databases in a long and complicated procedure: EDL staff needs to export all the results/GCs to be checked to an Excel file, followed by finding the suspicious GCs, which is done in a different program (WinREMS), According to the GC shapes (Figure 1 illustrates suitable and suspicious GC shapes) and the ratio between the elements result values, the inspecting technician corrects the data. The motivation for developing the new program is the complicated and time consuming process of our the manual procedure to the large amount of TLDs each month (13,000), similarly to other Dosimetry services that use computerized QC GC analysis. it is important to note that only ~25% of the results are above the EDL recorded level (0.10 mSv) and need to be inspected. Thus, the purpose of this paper is to describe a new program, TagQC, which allows a computerized QC GC analysis that identifies automatically, swiftly, and accurately suspicious TLD GC

  19. Utilization of thermoluminescent dosemeters for determination of exposure or absorbed dose in a radiation gamma or X radiation field with unknown spectral distribution

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1981-06-01

    Having in view the choice of the best pair of dosemeters to be used in the 'Tandem' method, the main response characteristics of LiF:Mg, Ti, Li 2 B 4 O 7 :Mn, CaSO 4 Dy, CaF 2 :Mn and CaF 2 :Dy thermoluminescent dosemeters and also some critical parameters in their calibration and evaluation processes were studied. Three different physical forms of TLD's were investigated: hot pressed chips, disc teflon dosemeters and glass mini TLD's. Their calibration factors were obtained for the energy of Cobalt-60 gamma rays. Their energy dependences normalized to 60 Co radiation were determined using spectral width as parameter. 'Tandens' formed by all TLD's evaluated were compaired. (E.G.) [pt

  20. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    Science.gov (United States)

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  1. Effects of 3d-4f magnetic exchange interactions on the dynamics of the magnetization of Dy(III)-M(II)-Dy(III) trinuclear clusters.

    Science.gov (United States)

    Pointillart, Fabrice; Bernot, Kevin; Sessoli, Roberta; Gatteschi, Dante

    2007-01-01

    [{Dy(hfac)(3)}(2){Fe(bpca)(2)}] x CHCl(3) ([Dy(2)Fe]) and [{Dy(hfac)(3)}(2){Ni(bpca)(2)}]CHCl(3) ([Dy(2)Ni]) (in which hfac(-)=1,1,1,5,5,5-hexafluoroacetylacetonate and bpca(-)=bis(2-pyridylcarbonyl)amine anion) were synthesized and characterized. Single-crystal X-ray diffraction shows that [Dy(2)Fe] and [Dy(2)Ni] are linear trinuclear complexes. Static magnetic susceptibility measurements reveal a weak ferromagnetic exchange interaction between Ni(II) and Dy(III) ions in [Dy(2)Ni], whereas the use of the diamagnetic Fe(II) ion leads to the absence of magnetic exchange interaction in [Dy(2)Fe]. Dynamic susceptibility measurements show a thermally activated behavior with the energy barrier of 9.7 and 4.9 K for the [Dy(2)Fe] and [Dy(2)Ni] complexes, respectively. A surprising negative effect of the ferromagnetic exchange interaction has been found and has been attributed to the structural conformation of these trinuclear complexes.

  2. Cytotoxic and genotoxic effect of the [166Dy]Dy/166Ho-EDTMP in vivo generator system in mice

    International Nuclear Information System (INIS)

    Pedraza-Lopez, Martha; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Morales-Ramirez, Pedro; Piedras-Ross, Josefa; Murphy-Stack, Eduardo; Hernandez-Oviedo, Omar

    2004-01-01

    Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. [ 166 Dy]Dy/ 166 Ho-ethylenediaminetetramethylene phosphonate (EDTMP) forms a stable in vivo generator system with selective skeletal uptake in mice; therefore, it could work as a potential and improved agent for marrow ablation. Induced bone marrow cytotoxicity and genotoxicity are determined by the reduction of reticulocytes (RET) and elevation of micronucleated reticulocyte (MN-RET) in peripheral blood and ablation by bone marrow histological studies. The aim of this study was to determine the bone marrow cytotoxic and genotoxic effect of the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system in mice and to evaluate by histopathology its myeloablative potential. Enriched 166 Dy 2 O 3 was irradiated and [ 166 Dy]DyCl 3 was added to EDTMP in phosphate buffer (pH 8.0) in a molar ratio of 1:1.75. QC was determined by TLC. Dy-EDTMP complex was prepared the same way with nonirradiated dysprosium oxide. A group of BALB/c mice were intraperitoneally injected with the radiopharmaceutical and two groups of control animals were injected with the cold complex and with 0.9% sodium chloride, respectively. A blood sample was taken at the beginning of the experiments and every 48 h for 12 days postinjection. The animals were sacrificed, organs of interest taken out and the radioactivity determined. The femur was used for histological studies. Flow cytometry analysis was used to quantify the frequency of RET and MN-RET in the blood samples. The MCNP4B Monte Carlo computer code was used for dosimetry calculations. Radiochemical purity was 99% and the mean specific activity was 1.3 MBq/mg. The RET and MN-RET frequency were statistically different in the treatment at the end of the 12-day period demonstrating cytotoxicity and genotoxicity induced by the in vivo generator system. The histology studies show that there was

  3. Comparison of neutron dose measured by Albedo TLD and etched tracks detector at PNC plutonium fuel facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Momose, T.; Shinohara, K.; Ishiguro, H.

    1996-01-01

    Power Reactor and Nuclear Fuel Development Corporation (PNC) has fabricated Plutonium and Uranium Mixed OXide (MOX) fuel for FBR MONJU at Tokai works. In this site, PNC/Panasonic albedo TLDs/1/ are used for personnel neutron monitoring. And a part of workers wore Etched Tracks Detector (ETD) combined with TLD in order to check the accuracy of the neutron dose estimated by albedo TLD. In this paper, the neutron dose measured by TLD and ETD in the routine monitoring is compared at PNC plutonium fuel facilities. (author)

  4. Purification and characterization of two DyP isozymes from Thanatephorus cucumeris Dec 1 specifically expressed in an air-membrane surface bioreactor.

    Science.gov (United States)

    Shimokawa, Takuya; Shoda, Makoto; Sugano, Yasushi

    2009-02-01

    DyP isozymes (DyP2 and DyP3) from the culture fluid of the fungus Thanatephorus cucumeris Dec 1 by air-membrane surface bioreactor were purified and characterized. The characteristics of DyP2 were almost the same as those of a recombinant DyP reported previously, but different from DyP3.

  5. Vivo dosimetry using TLD detectors in prostate seed implants of I-125: preliminary results; Dosimetria in vivo mediante detectores de TLD en implantes de prostata con semillas de I-125: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Reyes, A.; Pedro, A.; Bassas, P.; Duch, M. A.; Cros, M.; Mane, S.

    2011-07-01

    We present preliminary results of a new in vivo dosimetry technique that could allow to know immediately after implantation of the prostate if the dose distribution determined by the scheduler is similar to the actual dose measured with TLD detectors.

  6. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  7. Parallel analysis of film and TLD application in personal dosimetry of medical staff during application of invasive radiological procedures

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1997-01-01

    Although both types of dosimeters showed similar results for mentioned category of health care workers we wished to emphasize some advantages in use of TLD and film dosemeters in personal dosimetry. The main advantageous of film for dosimetric purposes are that it can provide visual representation of the radiation field and they are cheap, but there are lot of disadvantages. Advantages of TLD are based on: possibility for re-use, practically for whole users working life, small dimensions suitable for results, high precision and specially wide dose range. They are sensitive on low dose, practically for ten times more than film is. Disadvantages of TLD are based on their previous thermal and radiation history and on the fact that information about dose disappears after reading procedure. Considering advantages and disadvantages of both types of dosemeters we decided to propose TLD for routine hospital practice in personal dosimetry. (author)

  8. Some kinetic properties of DySnSe2 combination

    International Nuclear Information System (INIS)

    Murguzov, M.I.; Mammadova, E.R.

    2008-01-01

    Recently, to the acquisition of multi-component alloys and combination in the presence of rare-earth metals (REM) interest has grown considerably. According to preliminary data, in the presence of rare-earth metals you can obtain perspective semiconductor materials which are of practical importance, and can be used in various fields of microelectronics in a complex system of chalcogenides. DySnSe 2 combination is also includes to this system. Physical peculiarities of these combinations have been studied in wide interval. DySnSe 2 combination crystallizes in ortho rhombic crystal system and is an indemnification n-type semiconductor material. The mechanism of electrical conductivity in DySnSe 2 semiconductor combination is complicated and cargo carrier scattering changes at low temperatures. That is why, the mixed type conductivity occurs

  9. Surface magnetic phase transitions in Dy/Lu superlattices

    International Nuclear Information System (INIS)

    Goff, J.P.; Sarthour, R.S.; Micheletti, C.; Langridge, S.; Wilkins, C.J.T.; Ward, R.C.C.; Wells, M.R.

    1999-01-01

    Dy/Lu superlattices comprising ferromagnetic Dy blocks coupled antiferromagnetically across the Lu blocks may be modelled as a chain of XY spins with antiferromagnetic exchange and six-fold anisotropy. We have calculated the stable magnetic phases for the cases of large anisotropy and a field applied along an easy direction. For an infinite chain an intermediate phase (1, 5,...) is predicted, where the notation gives the angle between the moment and the applied field in units of π/3. Furthermore, the effects of surface reconstruction are determined for finite chains. A [Dy 20 Lu 12 ] 20 superlattice has been studied using bulk magnetization and polarized neutron reflectivity. The (1, 5,...) phase has been identified and the results provide direct evidence in support of the theoretical predictions. Dipolar forces are shown to account for the magnitude of the observed exchange coupling. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Modification of magnetoresistance and magnetic properties of Ni thin films by adding Dy interlayer

    Science.gov (United States)

    Vorobiov, S. I.; Shabelnyk, T. M.; Shutylieva, O. V.; Pazukha, I. M.; Chornous, A. M.

    2018-03-01

    The paper reports the influence of dysprosium (Dy) interlayer addition on structure, magnetoresistance and magnetic properties of nickel (Ni) thin films. Trilayer film systems Ni/Dy/Ni have been prepared by alternate electron-beam evaporation. It is demonstrated that all as-prepared and annealed Ni thin films have face-centered cubic structure. The composition of the samples after addition of the Dy interlayer corresponds to the combination of face-centered cubic (Ni) and hexagonal close-packed (Dy) structures. The structure of Ni/Dy/Ni film systems changes from amorphous to polycrystalline when Dy interlayer thickness (t Dy) is more than 15 nm. The value of magnetoresistance increases with the adding the Dy interlayer in both longitudinal and transverse geometries, meanwhile the anisotropic character of magnetoresistance field dependences retained. The saturation and reversal magnetizations are reduced with the increasing of the Dy thickness interlayer, while the coercivity takes the minimum value at t Dy = 15 nm. The following increasing of t Dy leads to increasing of coercivity near to three times. This result indicates the influence of the crystal structure on the magnetic properties of Ni thin films at adding Dy interlayer.

  11. Gypsum (CaSO4·2H2O) Scaling on Polybenzimidazole and Cellulose Acetate Hollow Fiber Membranes under Forward Osmosis

    Science.gov (United States)

    Chen, Si Cong; Su, Jincai; Fu, Feng-Jiang; Mi, Baoxia; Chung, Tai-Shung

    2013-01-01

    We have examined the gypsum (CaSO4·2H2O) scaling phenomena on membranes with different physicochemical properties in forward osmosis (FO) processes. Three hollow fiber membranes made of (1) cellulose acetate (CA), (2) polybenzimidazole (PBI)/polyethersulfone (PES) and (3) PBI-polyhedral oligomeric silsesquioxane (POSS)/polyacrylonitrile (PAN) were studied. For the first time in FO processes, we have found that surface ionic interactions dominate gypsum scaling on the membrane surface. A 70% flux reduction was observed on negatively charged CA and PBI membrane surfaces, due to strong attractive forces. The PBI membrane surface also showed a slightly positive charge at a low pH value of 3 and exhibited a 30% flux reduction. The atomic force microscopy (AFM) force measurements confirmed a strong repulsive force between gypsum and PBI at a pH value of 3. The newly developed PBI-POSS/PAN membrane had ridge morphology and a contact angle of 51.42° ± 14.85° after the addition of hydrophilic POSS nanoparticles and 3 min thermal treatment at 95 °C. Minimal scaling and an only 1.3% flux reduction were observed at a pH value of 3. Such a ridge structure may reduce scaling by not providing a locally flat surface to the crystallite at a pH value of 3; thus, gypsum would be easily washed away from the surface. PMID:24957062

  12. Impact of ANSI 2009 criteria for performance testing in TLD personnel monitoring

    International Nuclear Information System (INIS)

    MeenaI, P.; Rakesh, R.B.; Srivastava, Kshama; KoIambe, D.H.; Sapra, B.K.

    2014-01-01

    External Quality Assurance in TLD Personnel Monitoring Service was initiated in 1985, for periodic performance evaluation of various TLD Laboratories through postal exercise. Presently, all the 16 laboratories involved in Personnel Monitoring Service are covered under QA exercise. Since beginning, American National Standards Institute (ANSI) criteria have been adopted for performance testing in QA exercise. Presently, ANSI 2001 performance criteria along with ISO trumpet curve analysis method are being used for performance evaluation. In 2009, ANSI modified the performance evaluation criteria and this study evaluates its impact and feasibility of implementation of ANSI 2009 criteria in the quality assurance program for personnel monitoring. The performance of some laboratories evaluated using both ANSI 2001 and ANSI 2009 criteria have been discussed. The study shows that the ANSI 2009 criteria is more stringent and encourages even distribution of bias and standard deviation. This can be implemented with suitable modifications for performance evaluation

  13. Fast neutron responses of CaF2:Tm Teflon TLD discs of different thicknesses

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Hoffmann, W.

    1986-01-01

    The fact that in CaF 2 :Tm (TLD-300) the ratio of the heights of thermoluminescence (TL) glow peaks at 240 0 C and 150 0 C is greater for irradiations by high LET radiations than by gamma rays has been found useful for the simultaneous and separate measurement of fast neutron and gamma ray absorbed doses. A recent study has indicated that the mixed field dosimetric characteristics of CaF 2 :Tm could be significantly improved by using thin TLDs. In the present study, CaF 2 :Tm Teflon TLD discs of thickness as low as 0.05 mm were evaluated. The thin discs could be read out by using normal planchette heating if a 400 0 C heat treatment is given to the discs prior to irradiation and TL readout. Influence of encapsulation of thin dosemeters was studied and their utility in situations such as interface dosimetry is discussed. (author)

  14. The Dependence of the Dose Response Supralinearity of Peak 5 in TLD-100 on Recombination Temperature

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Satinger, D.; Oster, L.

    1999-01-01

    Isothermal readout of LiF:Mg,Ti (TLD-700) has recently been used to study the dependence of the supralinearity of peak 5 on recombination temperature. The results were interpreted to be in conflict with earlier results which investigated the effect of readout heating rate on the supralinearity of peak 5 in TLD-100. In this work the two experiments are inspected in greater detail. It is illustrated that the isothermal decay data is not in conflict with the heating rate data. However, the heating rate results do apparently indicate a strong transition in the temperature dependence of the relative strengths of the recombination and competitive cross sections at approximately 235 deg. C, which requires further study and analysis. (author)

  15. Further characteristics important in the operation of ceramic BeO TLD

    International Nuclear Information System (INIS)

    Gammage, R.B.

    1977-01-01

    There is now a considerable volume of published research dealing with ceramic BeO--TLD (Crase and Gammage, 1975; Yamashita et al., 1974; Scarpa et al., 1971). Its high sensitivity to radiation (1 mR), cheapness, commercial availability, non-toxicity, chemical stability, an atomic number of near tissue equivalence, and resistance to thermal fading, suggest that it should, by now, have found widespread acceptance as a TLD phosphor. It has not. There are only a small handful of reports dealing with the practical application of this type of dosimeter (Puite et al., 1974; Gammage and Haywood, 1976; Gesell et al., 1975). It seems wise, therefore, to look at the phosphor more closely and to focus on characteristics likely to cause problems under real operating conditions, especially those which are acting as a deterrent to its widespread acceptance. Operational characteristics were studied and the results are discussed

  16. Results and discussion of laboratory experiences with different automated TLD readers for personnel monitoring

    International Nuclear Information System (INIS)

    Regulla, D.F.; Drexeler, G.

    Although the film seems to continue serving as the main personnel dosemeter in Germany for the time in sight, the evolution of particularly solid state techniques and their properties are thoroughly considered with respect to a possible generalized application in personnel monitoring. For this reason different automated TLD systems that are commercially available have been investigated in the laboratory in order to find out their usefulness for a largescale or also decentralized service. Along with studying the dosimetrical and apparative parameters, the question has been discussed to which monitoring philosophy these TLD systems seem to fit. It is reported both on experimental experiences achieved as well as on the results of basic discussions that in return influence the discussion about the necessary outfit of personnel TL dosemeters

  17. PorTL - a compact, portable TLD reader for environmental and personal dosimetry

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Bodnar, L.; Csoke, A.; Feher, I.; Pazmandi, T.

    2005-01-01

    Thermoluminescent dosimeters (TLDs) are commonly used for environmental monitoring, for personal and medical dosimetry, for dosimetry in nuclear facilities, etc. Major advantages are their independence of the power supply, small dimension, sensitivity, good stability, wide measuring range, resistance to environmental changes and relatively low cost. The disadvantage is that the detector must be transported for evaluation to a laboratory equipped with a large, heavy and expensive TLD Reader operated by qualified personnel, which considerably increases the costs and delays results. To overcome this disadvantage, the KFKI Atomic Energy Research Institute (KFKI AEKI), in co-operation with BL Electronics (Hungary), has developed a new and unique TLD system containing a small, portable, battery powered and moderate-price reader for commercial use. This paper gives a detailed description and parameters of this system.(author)

  18. Dy163-Ho163 branching: an s-process barometer

    International Nuclear Information System (INIS)

    Beer, H.; Walter, G.; Macklin, R.L.

    1984-01-01

    The neutron capture cross sections of Dy163 and Er164 have been measured to analyze the s-process branching at Dy163-Ho163. The reproduction of the s-process abundance of Er164 via this branching is sensitive to temperature kT, neutron density, and electron density n/sub e/. The calculations using information from other branchings on kT and the neutron density n/sub n/ give constraints for n/sub e/ at the site of the s-process

  19. Optical properties of Dy3+ doped yttrium aluminium borate

    International Nuclear Information System (INIS)

    Vazquez, R MartInez; Osellame, R; Marangoni, M; Ramponi, R; Dieguez, E; Ferrari, M; Mattarelli, M

    2004-01-01

    A Dy 3+ doped yttrium aluminium borate (Dy:YAB) crystal has been optically characterized. The refractive indices at seven different wavelengths, ranging from the visible to the near infrared (IR), have been measured and the Sellmeier curves have been calculated. The polarized optical absorption spectra have been obtained at room temperature, and the Judd-Ofelt parameters have been calculated. The lifetime of the upper laser level 4 F 9/2 has been estimated and compared with the experimental value. Evidence of high luminescence quantum efficiency of the 4 F 9/2 state in YAB is provided by measured lifetimes

  20. Phosphors doped with Dy3+ and Gd3+ for lighting

    International Nuclear Information System (INIS)

    Su, Q; Pei, Z.; Zeng, Q.; Chi, L.

    1998-01-01

    Full text: Some heavy lanthanide ions with even atomic number such as Dy 3+ and Gd 3+ are abundant in the ion adsorption type deposit of China. Their price is cheap and they have specific spectroscopic properties which can be used as phosphors. Dy 3i on has two dominant bands in the emission spectrum. The yellow band (575 nm) corresponds to the hypersensitive transition 4 F 9/2 → 6 H 13/2 (ΔL=2, ΔJ=2), and the blue band (485 nm) corresponds to the 4 F 9/2 → 6 H 15/2 transition. Factors which influence on the yellow- to-blue intensity ratio (Y/B) were investigated. Adjusting to a suitable Y/B, Dy 3+ will emit white light with high colour temperature and can be used for lighting. But Dy 3+ ion has only narrow excitation bands of f-f transitions ranging from 300-500 nm, no broad excitation band such as charge transfer band or f-d transition band exists in the UV region 200-300 nm. Hence its luminescent efficiency is low when it is excited by UV radiation emitted from the mercury plasma. This is one of the drawbacks to its use as lamp phosphor. However, this can be overcome by sensitisation with Gd 3+ , Pb 2+ or other sensitisers such as vanadate shown in this report. Gd 3+ is not only a good matrix, but also a good sensitiser. Using its 8 S 7/2 → 6 D, 6 I and 6 P transitions, the UV excitation energy can be absorbed and transferred to the activator such as Dy 3+ . Therefore, in some cases Gd 3+ is better than Y 3+ which is optical inert as a matrix. For the phosphor Ca 1.96 Pb 0.04 RE 7.9 Dy 0.1 (SiO 4 ) 6 O 2 prepared by sol-gel method, the intensity of Dy 3+ in the Gd 3+ compound (RE=Gd 3+ ) is six times that in the Y 3+ compound. Some new phosphors doped with Dy 3+ and Gd 3+ prepared in our laboratory are reported

  1. Therapeutical radiopharmaceuticals based In vivo generator system [{sup 166} Dy] Dy/{sup 166} Ho; Radiofarmacos terapeuticos basados en un sistema de generador In vivo [{sup 166}Dy] Dy/{sup 166}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Ferro F, G.; Garcia S, L.; Monroy G, F.; Tendilla, J.I. [Gerencia de Aplicaciones Nucleares en la Salud, ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Pedraza L, M.; Murphy, C.A. de [Departamento de Medicina Nuclear, Instituto Nacional de Pediatria, Mexico D.F. (Mexico)

    2002-07-01

    At the idea to administer to a patient a molecule containing in it structure a father radionuclide, with a half life enough large which allows to the radiolabelled molecule to take up position specifically in a white tissue and decaying In vivo to the daughter radionuclide with properties potentially therapeutic, it is known as In vivo generator system. In this work the preparation and the preliminary dosimetric valuations of radiopharmaceuticals based In vivo generator system {sup 166} Dy Dy/{sup 166} Ho for applications in radioimmunotherapy, in the treatment of the rheumatoid arthritis and in the bone marrow ablation (m.o.) for candidates patients to bone marrow transplant are presented. (Author)

  2. Verification or treatment planning system of radiotherapy using TLD-100; Verificacion de los sistemas de planificacion de tratamiento de radioterapia empleando TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Pinuela, J., E-mail: jcpinuela@hotmail.co [Hospital Central de Maracay (Venezuela, Bolivarian Republic of). Servicio de Radioterapia

    2010-07-01

    The evaluation of the treatment planning system (TPS) used in radiotherapy Precise Plan, was carried out using TLD-100 dosimeters, comparing the dose obtained with an ionization chamber. The TLD-100 were calibrated using secondary standard of SSDL, selecting dosimeters which had a standard deviation less than 1% for dosimeter calibration and less than 5% for dosimeter of field, for the tests conducted in TPS, The Alderson Phantom was used to evaluate the wedge and bolus, and Lucy 3D allowed us to evaluate correspondence of CT numbers, volume expansion, beam shaping, precise dose and beam weigh assignment. It was observed that the results of Lucy 3D were within the values expected except the volume expansion process with more than 10% difference, the evaluation of beam modulators systems with wedges and bolus as beam shaping yielded values within the expected with variations less than 5% and to assess the supply of specific doses, it was observed that the values obtained were precise and accurate since the same variation was less than 0.5% for the test. The importance of assessing the TPS lies in our country there is no procedure to verify that system and these tests provide a basis for future comparisons. (author)

  3. Measurement of high natural background radiation levels by TLD at Cox's Bazar coastal areas in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Rahman, M.M.; Koddus, M.A.; Husain, S.R.; Malek, M.A.

    1987-01-01

    High natural background radiation levels at the Cox's Bazar coastal areas in Bangladesh were measured by LiF (TLD-100) dosemeters. The dose rates varied from 2621 to 35391 μGy.y -1 with a mean of 11968 μGy.y -1 . The average dose rate is found to significantly higher than the world average value. In order to formulate appropriate guidelines for radiation protection of the population in this area, the necessary recommendations are described. (author)

  4. Performance testing of the environmental TLD system for the Three Mile Island Nuclear Station.

    Science.gov (United States)

    Toke, L F; Carson, B H; Baker, G G; McBride, M H; Plato, P A; Miklos, J A

    1984-05-01

    Panasonic UD-801 thermoluminescent dosimeters ( TLDs ) containing two calcium sulfate phosphors were tested under Performance Specification 3.1 established by the American National Standard Institute ( ANSI75 ) and in the U.S. Nuclear Regulatory Commission's Regulatory Guide 4.13 ( NRC77 ). The specific qualifying tests included TLD uniformity, reproducibility, energy dependence and directional dependence. The overall measurement uncertainties and associated confidence levels are within the prescribed guidelines defined in the qualifying requirements for environmental TLDs .

  5. Evaluation of LiF:Mg,Ti (TLD-100 for Intraoperative Electron Radiation Therapy Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Raffaele Liuzzi

    Full Text Available Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs response to intraoperative electron radiation therapy (IOERT beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters.LiF:Mg,Ti dosimeters (TLD-100 were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy.The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05.This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  6. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford's mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue

  7. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    Energy Technology Data Exchange (ETDEWEB)

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford`s mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  8. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    Energy Technology Data Exchange (ETDEWEB)

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford's mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  9. Assessment of radiation exposure of nuclear medicine staff using personal TLD dosimeters and charcoal detectors

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, F.; Garcia-Talavera, M.; Pardo, R.; Deban, L. [Valladolid Univ., Dept. de Quimica Analitica, Facultad de Ciencias (Spain); Garcia-Talavera, P.; Singi, G.M.; Martin, E. [Hospital Clinico Univ., Servicio de Medicina Nuclear, Salamanca (Spain)

    2006-07-01

    Although the main concern regarding exposure to ionizing radiation for nuclear medicine workers is external radiation, inhalation of radionuclides can significantly contribute to the imparted doses. We propose a new approach to assess exposure to inhalation of {sup 131}I based on passive monitoring using activated charcoal detectors. We compared the inhalation doses to the staff of a nuclear medicine department, based on the measurements derived from charcoal detectors placed at various locations, and the external doses monitored using personal TLD dosimeters. (authors)

  10. Assessment of radiation exposure of nuclear medicine staff using personal TLD dosimeters and charcoal detectors

    International Nuclear Information System (INIS)

    Jimenez, F.; Garcia-Talavera, M.; Pardo, R.; Deban, L.; Garcia-Talavera, P.; Singi, G.M.; Martin, E.

    2006-01-01

    Although the main concern regarding exposure to ionizing radiation for nuclear medicine workers is external radiation, inhalation of radionuclides can significantly contribute to the imparted doses. We propose a new approach to assess exposure to inhalation of 131 I based on passive monitoring using activated charcoal detectors. We compared the inhalation doses to the staff of a nuclear medicine department, based on the measurements derived from charcoal detectors placed at various locations, and the external doses monitored using personal TLD dosimeters. (authors)

  11. TLD gamma-ray energy deposition measurements in the zero energy fast reactor ZEBRA

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1977-01-01

    A recent study of gamma-ray energy deposition was carried out in the Zebra reactor at AEE Winfrith during a collaborative programme between the UKAEA and PNC of Japan. The programme was given the title MOZART. This paper describes the TLD experiments in the MOZART MZB assembly and discusses the technique and various corrections necessary to relate the measured quantity to the calculated energy deposition

  12. Measurement of exposure dose rate by TLD in 60Co garden

    International Nuclear Information System (INIS)

    Fan Chengfang; Li Pinfang; Wu Maoliang; Zhao Quan

    1987-01-01

    The use of TLD method to measure exposure dose rate in 60 Co garden is described. As compared with chemical dosimetry, the relative deviation of measurement would not exceed 10%. The good repeatability has been proved by comparing the measurements of different times and distances with correction of decay law and 1/1 2 law. Besides, the distribution of exposure dose rate was influenced by scattering of the living plants

  13. The evaluation of dose of TSEI with TLD and diode detector of the uterine cervix cancer

    International Nuclear Information System (INIS)

    Je, Young Wan; Na, Keyung Su; Yoon, Il Kyu; Park, Heung Deuk

    2005-01-01

    To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and 116 degree. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. The deviations of dose detected with TLD from tumor dose were CA + 6%, thigh + 8%, umbilicus + 4%, calf - 8%, vertex - 74.4%, deep axillae - 10.2%, anus and testis - 87%, sole - 86% and nails shielded with 4 mm lead + 4%. The deviations of dose detected with diode were - 4.5% ∼ + 5% at the patient center and - 1.1% ∼ + 1% at the speller. The deviation of total skin dose was + 8% ∼ - 8% and that deviation was within the acceptable range(±10%). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  14. Comparative study of trapping parameters of LiF(TLD-100) from different production batches

    Energy Technology Data Exchange (ETDEWEB)

    Bos, A.J.J.; Piters, T.M.; Vries, W. de; Hoogenboom, J.E. (Delft Univ. of Technology (Netherlands). Interfaculty Reactor Institute)

    1990-01-01

    Computerised glow curve analysis has been used to determine the trapping parameters of the main peaks of the thermoluminescent (TL) material LiF(TLD-100). The TL material (solid state chips) originated from six different production batches with at least 19 chips per batch. The maxima of glow peaks 2 to 5 are found at the same temperature within very small limits. The activation energy and frequency factor of the main glow peak (peak 5) of TLD-100 originating from two batches differ significantly from those of the other four investigated batches. Nevertheless, the sensitivity of glow peak 5 is more or less the same for all batches. The trapping parameters of glow peaks 2 to 4 of TLD-100 vary little from batch to batch. The measured half-life of peak 2 differed strongly from batch to batch. For all investigated peaks no correlation has been found between glow peak sensitivity and trapping parameters. The results of this study suggest that both defect concentration and nature of the trapping centres vary from batch to batch. It would appear that as a consequence of selection by the manufacturer, the differences between the batches in terms of total light output are small. (author).

  15. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  16. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    International Nuclear Information System (INIS)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-01-01

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10 11 Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410 9 Gy/s within 2% (OSL and TLD) and up to 1510 9 Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  17. Application of Glow Curve Deconvolution Method to Evaluate Low Dose TLD LiF

    International Nuclear Information System (INIS)

    Kurnia, E; Oetami, H R; Mutiah

    1996-01-01

    Thermoluminescence Dosimeter (TLD), especially LiF:Mg, Ti material, is one of the most practical personal dosimeter in known to date. Dose measurement under 100 uGy using TLD reader is very difficult in high precision level. The software application is used to improve the precision of the TLD reader. The objectives of the research is to compare three Tl-glow curve analysis method irradiated in the range between 5 up to 250 uGy. The first method is manual analysis, dose information is obtained from the area under the glow curve between pre selected temperature limits, and background signal is estimated by a second readout following the first readout. The second method is deconvolution method, separating glow curve into four peaks mathematically and dose information is obtained from area of peak 5, and background signal is eliminated computationally. The third method is deconvolution method but the dose is represented by the sum of area of peak 3,4 and 5. The result shown that the sum of peak 3,4 and 5 method can improve reproducibility six times better than manual analysis for dose 20 uGy, the ability to reduce MMD until 10 uGy rather than 60 uGy with manual analysis or 20 uGy with peak 5 area method. In linearity, the sum of peak 3,4 and 5 method yields exactly linear dose response curve over the entire dose range

  18. The effect of the build-up wall at the TLD calibration using Co-60

    International Nuclear Information System (INIS)

    Nariyama, N.

    2000-01-01

    Absorbed dose in thermoluminescent dosimeter (TLD) material at the calibration using Co-60 gamma rays depends on the TLD thickness and the wall material used for electric equilibrium condition. The relation was examined for LiF, BeO and CaF 2 TLDs sandwiched with PMMA, Teflon and Pyrex glass walls using a Monte Carlo transport code and compared with cavity ionization theory calculations. For the mismatched combination of LiF, BeO/Pyrex glass and CaF 2 /PMMA, it was found that the energy deposition did not change monotonously with TLD thickness from small cavity to large cavity value: a depression observed around 1-mm thickness for LiF/Pyrex glass and a peak around 0.6-mm thickness for CaF 2 /PMMA. The phenomena were explained by using different exponential attenuation coefficients β and β' for the weighting functions of cavity theory. Moreover, use of large cavity values was found to lead possibly to 3-5% errors in the calibration of thin TLDs. (author)

  19. The study of new calibration features in the Harshaw TLD system

    International Nuclear Information System (INIS)

    Luo, L.Z.

    2005-01-01

    Full text: In the Harshaw TLD system, there are three key calibration procedures; the reader, the dosimeter and the algorithm. These procedures must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosimeter calibration, Harshaw recommends a pre-fade and a post-fade of 24 - 48 hours when calibrating the system. Harshaw also emphasizes that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the operating system. These new features are auto calibration, auto QC and auto blank, and they give the user the ability to set up the clear-expose-read performed automatically in a sequence for each dosimeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of auto calibration / auto QC to the TLD operation. (author)

  20. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Cecilia, A.; Baccaro, S.; Cemmi, A. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Colli, V.; Gambarini, G. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF{sub 2}:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH{sub 3}CH(NH{sub 2})COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT. (authors)

  1. Evaluation of mixed energy neutron doses using TLD NG-67 type

    International Nuclear Information System (INIS)

    Akhadi, Mukhlis; Thoyib Thamrin, M; Usmiyati Dewi, K.

    2000-01-01

    A research has been carried out to develop dose evaluation method of mixed neutron source with its neutron doses can be classified to two groups, I.e neutron doses with energy ≥ 0.5 eV and thermal neutron doses with energy less than 0.5 e V consist of epithermal and fast neutron, but in this research they were classified as fast neutron. Development of this dose evaluation method was carried out by sensitivity (S) intercomparison of TLD-600 to fast neutron, mixed energy neutron of nuclear rectors, and thermal neutron. From the experiment it was obtained that the value of Sfast : Sreactor : Sthermal = 0.005 : 0.010 : 1. Calibration factor (CF) of TLD is defined as 1/S. from the sensitivity data it can be obtained that the value of Cffast : Cfreactor : Cfthermal = 200 :100 : 1. The value of Cfreactor can be applied for mixed energy neutron doses evaluation of TLD-600. Key word : dosemeter, neutron dose, calibration factor, fast neutron, thermal neutron, nuclear reactor

  2. Unexpected structure in the E2 quasicontinuum spectrum of 154Dy

    International Nuclear Information System (INIS)

    Holzmann, R.; Khoo, T.L.; Ma, W.C.

    1988-01-01

    The evolution of the γ quasicontinuum spectrum with neutron number has been investigated in the sequence of dysprosium isotopes /sup 152,154,156/Dy. The three nuclei display a pronounced collective E2 component. In 154 Dy this component shows an unexpected splitting into two distinct parts, signifying a structural change along the γ cascade. The E2 and statistical components can be reproduced in simple γ cascade calculations; in 152 Dy and 156 Dy only rotational bands were included, whereas in 154 Dy additional vibration-like transitions were required to reproduce the two E2 peaks. 11 refs., 2 figs

  3. Mechanical and corrosion properties of binary Mg–Dy alloys for medical applications

    International Nuclear Information System (INIS)

    Yang Lei; Huang Yuanding; Peng Qiuming; Feyerabend, Frank; Kainer, Karl Ulrich; Willumeit, Regine; Hort, Norbert

    2011-01-01

    Microstructure, mechanical and corrosion properties of binary magnesium–dysprosium (Mg-5, 10, 15, 20 wt.% Dy) alloys were investigated for medical applications. In the as-cast condition, the distribution of Dy is quite inhomogeneous. Mg–10Dy alloy exhibits a moderate tensile and compression yield strength, and the best elongation and corrosion resistance. After T4 (solutionizing) treatment, the distribution of Dy becomes homogeneous. The tensile and compression yield strength of all Mg–Dy alloys decreases. The elongation remains unchanged, while the corrosion resistance is largely improved after T4 treatment.

  4. Mechanical and corrosion properties of binary Mg-Dy alloys for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang Lei, E-mail: lei.yang@hzg.de [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Max-Planck-Str. 1, D-21502 Geesthacht (Germany); Yuanding, Huang; Qiuming, Peng; Feyerabend, Frank; Kainer, Karl Ulrich; Willumeit, Regine; Hort, Norbert [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Max-Planck-Str. 1, D-21502 Geesthacht (Germany)

    2011-12-15

    Microstructure, mechanical and corrosion properties of binary magnesium-dysprosium (Mg-5, 10, 15, 20 wt.% Dy) alloys were investigated for medical applications. In the as-cast condition, the distribution of Dy is quite inhomogeneous. Mg-10Dy alloy exhibits a moderate tensile and compression yield strength, and the best elongation and corrosion resistance. After T4 (solutionizing) treatment, the distribution of Dy becomes homogeneous. The tensile and compression yield strength of all Mg-Dy alloys decreases. The elongation remains unchanged, while the corrosion resistance is largely improved after T4 treatment.

  5. A study on dose attenuation in bone density when TBI using diode detector and TLD

    International Nuclear Information System (INIS)

    Im, Hyun Sil; Lee, Jung Jin; Jang, Ahn Ki; KIm, Wan Sun

    2003-01-01

    Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10 MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were 92.78±3.3, 104.34±2.3, 98.03±1.4, 99.9±2.53, 98.17±0.56 respectably. Measured mid-depth dose of pelvis, knees and ankles were 86±1.82, 93.24±2.53, 91.50±2.84 respectably. There were 6.67%-11.65% dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were 95.23±1.18, 98.33±0.6, 93.5±1.5, 87.3±1.5, 86.90±1.16 respectably. There were 4.53%-12.6% dose attenuation at mid-depth in pelvis, knees and ankles. We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  6. Properties of Excited States in the 160 Dy Nucleus

    Czech Academy of Sciences Publication Activity Database

    Adam, Jindřich; Honusek, Milan; Dobeš, Jan

    2005-01-01

    Roč. 32, - (2005), s. 181-203 ISSN 1310-0157 R&D Projects: GA MŠk 1P04LA213 Institutional research plan: CEZ:AV0Z10480505 Keywords : 160Dy nucles Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders

  7. Bulk study of a DyNiAl single crystal

    Czech Academy of Sciences Publication Activity Database

    Prchal, J.; Andreev, Alexander V.; Javorský, P.; Honda, F.; Jurek, Karel

    272-276, - (2004), e419-e420 ISSN 0304-8853 R&D Projects: GA ČR GA106/02/0943 Keywords : rare-earth * DyNiAl * magnetic anisotropy * single crystal Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.031, year: 2004

  8. Equilibrium and kinetics studies of metal ion adsorption on dyed ...

    African Journals Online (AJOL)

    Batch equilibration studies were conducted to determine the nature of adsorption of Zn (II) and Cu (II) onto dyed coconut pollens. The nature of adsorption of metal ions was explained using the Langmuir equation. The calculated values of equilibrium parameter indicated favourable adsorption by the adsorbents. Also the ...

  9. Search for neutrinoless double-electron capture of 156Dy

    Science.gov (United States)

    Finch, S. W.; Tornow, W.

    2015-12-01

    Background: Multiple large collaborations are currently searching for neutrinoless double-β decay, with the ultimate goal of differentiating the Majorana-Dirac nature of the neutrino. Purpose: Investigate the feasibility of resonant neutrinoless double-electron capture, an experimental alternative to neutrinoless double-β decay. Method: Two clover germanium detectors were operated underground in coincidence to search for the de-excitation γ rays of 156Gd following the neutrinoless double-electron capture of 156Dy. 231.95 d of data were collected at the Kimballton underground research facility with a 231.57 mg enriched 156Dy sample. Results: No counts were seen above background and half-life limits are set at O (1016-1018) yr for the various decay modes of 156Dy. Conclusion: Low background spectra were efficiently collected in the search for neutrinoless double-electron capture of 156Dy, although the low natural abundance and associated lack of large quantities of enriched samples hinders the experimental reach.

  10. Viscosity, fission time scale and deformation of Dy-156

    NARCIS (Netherlands)

    van't Hof, G; Bacelar, JCS; Dioszegi, [No Value; Harakeh, MN; Hesselink, WHA; Kalantar-Nayestanaki, N; Kugler, A; van der Ploeg, H; Plompen, AJM; van Schagen, JPS

    1998-01-01

    In the fusion-fission reaction Ar-40 + Cd-116 --> Dy-156*, fission, at E-b = 216 MeV and 238 MeV, gamma-rays were measured in coincidence with fission fragments. The interpretation of the gamma-ray spectra is done with the help of a modified version of the statistical-model code CASCADE. The spectra

  11. ions (RE = La, Pr, Nd, Sm, Gd and Dy)

    Indian Academy of Sciences (India)

    ) zirconia), tendency of phase transformation (tetragonal to monoclinic () zirconia) and lattice strain were studied with mechanical property e.g. tensile strength of sol–gel derived ZrO2–2 mol% RE2O3 (RE = La, Pr, Nd, Sm, Gd and Dy) spun ...

  12. Anisotropy of the magnetocaloric effect in DyNiAl

    Czech Academy of Sciences Publication Activity Database

    Kaštil, J.; Javorský, P.; Andreev, Alexander V.

    2009-01-01

    Roč. 321, č. 15 (2009), s. 2318-2321 ISSN 0304-8853 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetocaloric effec * DyNiAl * magnetism * anisotropy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.204, year: 2009

  13. Surface activation of dyed fabric for cellulase treatment.

    Science.gov (United States)

    Schimper, Christian B; Ibanescu, Constanta; Bechtold, Thomas

    2011-10-01

    Surface activation of fabric made from cellulose fibres, such as viscose, lyocell, modal fibres and cotton, can be achieved by printing of a concentrated NaOH-containing paste. From the concentration of reducing sugars formed in solution, an increase in intensity of the cellulase hydrolysis by a factor of six to eight was observed, which was mainly concentrated at the activated parts of the fabric surface. This method of local activation is of particular interest for modification of materials that have been dyed with special processes to attain an uneven distribution of dyestuff within the yarn cross-section, e.g., indigo ring-dyed denim yarn for jeans production. Fabrics made from regenerated cellulose fibres were used as model substrate to express the effects of surface activation on indigo-dyed material. Wash-down experiments on indigo-dyed denim demonstrated significant colour removal from the activated surface at low overall weight loss of 4-5%. The method is of relevance for a more eco-friendly processing of jeans in the garment industry. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Thermal characterization of (U, Dy)O2 pellets

    International Nuclear Information System (INIS)

    Pelloni, M; Bianchi, L; Pablovich, M.E; Kaufmann, F; Kempf, R

    2012-01-01

    The thermal diffusivity of (U,Dy)O 2 pellets were determined in the temperature range 250 K to 1600 K measured by the laser flash method. The dependence of thermal with temperature and dysprosium content was studied and found in good agreement with physical models available (author)

  15. Studies of normal deformation in {sup 151}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Nisius, D.; Janssens, R.V.F.; Crowell, B. [and others

    1995-08-01

    The wealth of data collected in the study of superdeformation in {sup 151}Dy allowed for new information to be obtained on the normally deformed structures in this nucleus. At high spin several new yrast states have been identified for the first time. They were associated with single-particle excitations. Surprisingly, a sequence was identified with energy spacings characteristic of a rotational band of normal ({beta}2 {approximately} 0.2) deformation. The bandhead spin appears to be 15/2{sup -} and the levels extend up to a spin of 87/2{sup -}. A clear backbend is present at intermediate spins. While a similar band based on a bandhead of 6{sup +} is known in {sup 152}Dy, calculations suggest that this collective prolate band should not be seen in {sup 151}Dy. In the experiment described earlier in this report that is aimed at determining the deformations associated with the SD bands in this nucleus and {sup 152}Dy, the deformation associated with this band will be determined. This will provide further insight into the origin of this band.

  16. Corrosion study on high power feeding of telecomunication copper cable in 5 wt.% CaSO4.2H2O solution

    Science.gov (United States)

    Shamsudin, Shaiful Rizam; Hashim, Nabihah; Ibrahim, Mohd Saiful Bahri; Rahman, Muhammad Sayuzi Abdul; Idrus, Muhammad Amin; Hassan, Mohd Rezadzudin; Abdullah, Wan Razli Wan

    2016-07-01

    The studies were carried out to find out the best powering scheme over the copper telephone line. It was expected that the application of the higher power feeding could increase the data transfer and capable of providing the customer's satisfaction. To realize the application of higher remote power feeding, the potential of corrosion problem on Cu cables was studied. The natural corrosion behaviour of copper cable in the 0.5% CaSO4.2H2O solution was studied in term of open circuit potential for 30 days. The corrosion behaviour of higher power feeding was studied by the immersion and the planned interval test to determine the corrosion rate as well as the effect of voltage magnitudes and the current scheme i.e. positive direct (DC+) and alternating current (AC) at about 0.40 ± 0.01 mA/ cm2 current density. In the immersion test, both DC+ and AC scheme showed the increasing of feeding voltage magnitude has increased the corrosion rate of Cu samples starting from 60 to 100 volts. It was then reduced at about 100 - 120 volts which may due to the passive and transpassive mechanism. The corrosion rate was slowly reduced further from 120 to 200 volts. Visually, the positively charged of Cu cable was seems susceptible to severe corrosion, while AC scheme exhibited a slight corrosion reaction on the surface. However, the planned interval test and XRD results showed the corrosion activity of the copper cable in the studied solution was a relatively slow process and considered not to be corroded as a partially protective scale of copper oxide formed on the surface.

  17. Recommendations: Introducing the quality system into the use of significant ionizing radiation sources in radiotherapy. TLD audit by mail within the quality system in radiotherapy

    International Nuclear Information System (INIS)

    Ekendahl, D.; Valenta, J.; Horakova, I.

    2005-01-01

    The publication consists of the following sections: TLD measurement methodology (Description of the TLD system; Dose determination); TLD audit in radiotherapy: methodologies and evaluation of results (Checking the dose calculated by the planning system and beam quality control; Checking the calculated dose distribution using a versatile phantom; Checking the calculated doses for linear accelerators with multilammelar collimators; Evaluation and analysis of results; Organizing a performing audits by mail); and Annexes: Detailed guidelines and protocols for radiotherapy departments. (P.A.)

  18. Luminescent properties in films of ZrO2: Dy

    International Nuclear Information System (INIS)

    Martinez, R. C.; Guzman, J.; Rivera, T.; Ceron, P.; Montes, E.; Guzman, D.; Garcia H, M.; Falcony, C.; Azorin, J.

    2014-08-01

    In this work the luminescent characterization of zirconium oxide (ZrO 2 ) films impure with dysprosium (Dy +3 ) is reported, obtained by means of the ultrasonics spray pyrolysis technique. The films were deposited on glass substrates (Corning), in a temperatures interval of 400 to 550 grades C, using as precursor elements Zirconium oxide chloride octahydrate (ZrOCl 2 ·8H 2 O) and Dysprosium tri-chloride (DyCl 3 ), dissolved in deionized water, varying the concentration of the contaminated from the 1 to 20 atomic % with relationship to the zirconium in solution. The luminescent characterization was analyzed by means of photoluminescence and thermoluminescence. The photoluminescence results showed a spectrum with three maxima which correspond to the electronic transitions 4 F 9/2 - 6 H 15/2 , 4 F 9/2 - 6 H 13/2 and 4 F 9/2 - 6 H 11/2 characteristics of the Dy 3+ ion. The thermoluminescence (Tl) response when being exposed to a monochrome UV beam in 240 nm showed a wide curve that exhibits a maxim centered in 200 grades C. The Tl response of ZrO 2 :Dy in function of the dose was shown lineal in the interval of 24 mJ/cm 2 to 432 mJ/cm 2 . A study of the repeatability and dissipation of the ZrO 2 :Dy Tl response is included. Considering the shown previous results we can conclude that the ZrO 2 in film form obtained by spray pyrolysis has luminescent properties in 240 nm. (Author)

  19. Reasons for deviations outside the acceptance limits in the IAEA/WHO TLD audits for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Vatnitsky, Stanislav; Izewska, Joanna

    2002-01-01

    The main purpose of the IAEA/WHO TLD postal dose audit programme for dosimetry in radiotherapy [1] is to provide an independent verification of the dose delivered by treatment machines in radiotherapy hospitals. The results of the TLD audit are considered acceptable if the relative deviation between the participant's stated dose and the TLD determined dose is within ±5%. The goal of this note is to draw the attention of participants of the TLD programme to some of the common reasons for deviations outside the acceptance limits. Armed with this knowledge, other participants may avoid similar problems in the future. The analysis of deviations presented here is based on the results of TLD audits of the calibration of approximately 1000 Co-60 beams and 600 high-energy X-ray beams performed in the period 1996-2001. A total of 259 deviations outside the ±5% limits have been detected, including 204 deviations for Co-60 beams (20% of all Co-60 beams checked) and 55 for high-energy X-ray beams (10% of all X-ray beams checked). It is worth mentioning that the percentage of large deviations (beyond 10%) is also higher for Co-60 beams than for highenergy X-ray beams. Some problems may be caused by obsolete dosimetry equipment or poor treatment machine conditions. Other problems may be due to insufficient training of staff working in radiotherapy. The clinical relevance of severe TLD deviations detected in the audit programme was confirmed in many cases, but, fortunately, not all-poor dosimetric results reflect deficiencies in the calibration of clinical beams or machine faults. Sometime it happens, that the TLDs are irradiated with an incorrect dose due to misunderstanding of the instructions on how to perform the TLD irradiation. Such dosimetry errors would have no direct impact on actual dose delivered to a patient

  20. Study of the structure of the transition nuclei 152Dy, 154Dy and 156Er at high angular momentum

    International Nuclear Information System (INIS)

    Azgui, F.

    1985-01-01

    Measurements of feeding times of high spin yrast states in 152 Dy, 154 Dy and 156 Er were utilized to obtain information about possible spin dependent shape changes. Feeding times as well as lifetimes were determined with the recoil distance technique. In 152 Dy only long feeding times (> 10 ps) could be identified, indicating that the aligned-particle yrast states are fed through configuration of similar character, with little direct population from collective cascade in the continuum region. In 154 Dy discrete states with I ≤ 30 have lifetimes which are characteristically collective, whereas the preyrast cascade exhibit both fast ( 10 ps) feeding components. The latter imply a change with increasing spin from collective to aligned-particle character, signalling a prolate to oblate shape transition. In 156 Er the yrast states up to spin 20 ℎ were found to be collective. These levels are fed, however, from long-lived high spin states, causing time delay up to ∼ 100 ps, the existence of which is interpreted as a signature for an oblate shape at high spin [fr

  1. Luminescence studies on Dy3+ and Dy3+:Eu3+ co-doped boro-phosphate glasses for WLED applications

    Science.gov (United States)

    Vijayakumar, M.; Uma, V.; Arunkumar, S.; Marimuthu, K.

    2015-06-01

    Dy3+ and Dy3+:Eu3+ co-doped boro-phosphate glasses have been prepared and optically characterized using absorption, luminescence and decay measurements. The Nephelauxetic ratios (β), Bonding parameters (δ) and Judd-Ofelt (JO) intensity parameters Ωλ (λ = 2, 4 and 6) were calculated to study the nature of the environment around the RE3+ ions in the prepared glasses. The yellow to blue (Y/B) intensity ratio and the chromaticity color coordinates were calculated from the luminescence measurements. The lifetimes of the 4F9/2 excited level were measured using decay curves and is found to decrease in the Dy3+:Eu3+ co-doped glass due to the occurrence of resonant energy transfer between Dy3+-Eu3+ ions and the non-exponential decay rates have been fitted with Inokuti-Hirayama (IH) model. The decay curves are well fitted for S= 6 suggesting that the interaction between active ions for the energy transfer is of dipole-dipole nature.

  2. Comparison of wrist and head TLD doses with whole body TLD doses during high active jobs at RAPS-5 and 6

    International Nuclear Information System (INIS)

    Sharma, Ravi Kant; Abhishek, Neel; Kakkar, Amandeep; Kumar, Rajesh

    2016-01-01

    In nuclear power plant radiation dose monitoring and assessment is done to control the individual dose and station collective doses. While performing a radioactive job on systems or equipment with significant radiation levels of non uniform and beaming radiation; there is potential of localized exposure to extremities hands in particular and lens of the eye in comparison to other body parts. Keeping in view of this, separate equivalent dose limit to the extremities (hands and feet) and lens of the eye are defined by ICRP. A study has been carried out during Biennial Shutdown (BSD) of RAPS-6 in the month of October-2015 to establish the correlation between the doses received by chest TLDs which is being used to estimate the effective whole body dose of the radiation worker and the doses received in wrist TLD and head TLDs which are being used to monitor the equivalent dose received by hands and lens of the eye with applying a suitable correction factor

  3. Effect of Dy additions on microstructure and magnetic properties of Fe-Nd-B magnets

    International Nuclear Information System (INIS)

    Ramesh, R.; Thomas, G.; Ma, B.M.

    1987-05-01

    It is shown that increasing additions of Dy causes the remanence B/sub r/ to decrease linearly. The intrinsic coercivity, iHc, increases sharply for small additions of Dy, but the increase is not proportional for higher Dy contents. The iHc increases almost linearly with the effective anisotropy field of the RE 2 Fe 14 B phase until the Dy content is about 10% of the total rare earth content. Above this concentration, there is strong deviation from linearity. Various types of possible concentration profiles of the substituted rare earth are suggested. It is also argued that preferential segregation of Dy to the interfaces could be beneficial in increasing the nucleation field. Morphologically there is no apparent effect of Dy on the microstructure. However, in the 5 atomic % Dy sample, Dy rich oxides were observed. It is shown through Energy Dispersive Xray Spectroscopy (EDXS) line profiling that Dy partitions preferentially into the RE 2 Fe 14 B phase in all the cases. No segregation of Dy to the interphase interfaces has been detected

  4. TLD postal dose quality audit service for Co-60 beams in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    This report presents the methodology and experience of the Cuban's Secondary Standard Dosimetry Laboratory for the implementation of postal dose quality audits service for Co-60 beams in reference conditions, using TLDs. Under coordinated research project (Contract 10794) were bought (TLD -100) Tl rods type JR 1152F made in China, with dimensions of 6 mm x 1 mm x 1 mm. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout (100 rods approximately), four serial times in the same geometrical conditions, to read them out and to attribute to each of them a sensitivity factor. This sensitivity factor is equal to average for the 4 cycle of irradiation and readout of the quote between the TL readout from dosimeter i and the mean of all values for each cycle. The TLD signal was read using HARSHAW 2000C/B reader. The results obtained in the external verification of the accuracy of the dose determination by the TLD system were performed in cooperation with IAEA Dosimetry Laboratory at Seibersdorf in different years are shown, the results obtained of the quality audits carried out to the different services of radiotherapy of the country are analysed also. The quality audits are an useful tool for the improvement of the accuracy in the dosimetry of clinical beams of radiotherapy with Co-60, contributing this way to the improvement of the life quality to cancer patients of the Cuban system of health. (author)

  5. The Ras antagonist, farnesylthiosalicylic acid (FTS, decreases fibrosis and improves muscle strength in dy/dy mouse model of muscular dystrophy.

    Directory of Open Access Journals (Sweden)

    Yoram Nevo

    Full Text Available The Ras superfamily of guanosine-triphosphate (GTP-binding proteins regulates a diverse spectrum of intracellular processes involved in inflammation and fibrosis. Farnesythiosalicylic acid (FTS is a unique and potent Ras inhibitor which decreased inflammation and fibrosis in experimentally induced liver cirrhosis and ameliorated inflammatory processes in systemic lupus erythematosus, neuritis and nephritis animal models. FTS effect on Ras expression and activity, muscle strength and fibrosis was evaluated in the dy(2J/dy(2J mouse model of merosin deficient congenital muscular dystrophy. The dy(2J/dy(2J mice had significantly increased RAS expression and activity compared with the wild type mice. FTS treatment significantly decreased RAS expression and activity. In addition, phosphorylation of ERK, a Ras downstream protein, was significantly decreased following FTS treatment in the dy(2J/dy(2J mice. Clinically, FTS treated mice showed significant improvement in hind limb muscle strength measured by electronic grip strength meter. Significant reduction of fibrosis was demonstrated in the treated group by quantitative Sirius Red staining and lower muscle collagen content. FTS effect was associated with significantly inhibition of both MMP-2 and MMP-9 activities. We conclude that active RAS inhibition by FTS was associated with attenuated fibrosis and improved muscle strength in the dy(2J/dy(2J mouse model of congenital muscular dystrophy.

  6. Isothermal sections at 500 deg C of the Dy-V-Al and Dy-Cr-Al systems in the aluminium rich regions

    International Nuclear Information System (INIS)

    Rykhal', R.M.; Zarechnyuk, O.S.; Mats'kiv, O.P.

    1979-01-01

    X-ray diffraction and microscopic analyses have been used to investigate the ternary system dysprosium-vanadium-aluminium in the aluminium rich region. In the system Dy-V-Al two ternary compounds have been found: DyV 2 Al 20 (cubic structure, CeCr 2 Al 20 type, a=14.54 A and approximately DyVAl 8 (hexagonal crystal system, structure unknown, a=10.86, c=17.71 A, c/a=1.631). In the system dysprosium-chromium-aluminium three ternary compounds have been found: DyCr 2 Al 20 (cubic structure, CeCr 2 Al 20 type, a=14.39), approximately equal to DyCrAl 8 ) hexagonal crystal system, structure type unkown a=10.75, c=17.60 A, c/a=1.637) and DyCr 4 Al 8 (tetragonal structure, CeMn 4 Al 8 type, a=8.87, c=5.04 A, c/a=0.568). Isothermal sections of the systems Dy-V-Al and Dy-Cr-Al have been plotted at 500 deg C

  7. A quality control program for the thermoluminescence dosimeter (TLD) in personnel radiation monitoring

    International Nuclear Information System (INIS)

    Seo, Kyung Won; Kim, Jang Lyul; Lee, Sang Yoon; Lee, Hyung Sub

    1994-01-01

    High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The ministry of science and technology (MOST) issued a ministerial ordinance (No 199-15) about the technical criteria on personnel dosimeter processors on 1992. The purpose of this quality control program is to prescribe the procedures approved by the management of KAERI for implementing a quality badge service by means of TLD for personnel working in an area where they may be exposed to ionization radiation. (Author) 10 refs

  8. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  9. TLD Quality Assurance (QA) network in radiotherapy and radiology in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Novak, N.; Novotny, J.

    2002-01-01

    Full text: The Czech TLD QA network was established in 1997, as a part of the External Auditing Group (EAG) originated in 1995, in order to perform an independent quality audit in external beam therapy for two purposes: a) to unify the dose within radiotherapy departments, b) to impact state supervision. On basis of a good experience with this network in radiotherapy, new methods were developed to expand the network also to radiology in order to simplify the operation of state supervision. The TLD QA network in dental radiology has been brought into practice in 2001. Both the TLD audits performed in radiotherapy and radiology are realized via mailed dosimetry. In radiotherapy, two modes of the audit are used. Basic mode of TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. According to Czech regulations every beam must be checked in this way at least once during two years' period. Advanced mode consists of measurements under both reference and non- reference conditions using Leuven multi-purpose phantom for photon beams. It enables to check a substantial part of the treatment planning process inclusive of final dose realization of the planned radiotherapy. The radiotherapy centers are instructed to deliver absorbed dose of 2 Gy to the TLDs on central beam axis based on calculated treatment time or monitor units by their treatment planning system for a particular treatment set-up. In this way the TLD measured doses are compared with the calculated ones. Deviations of ±3% are considered acceptable for both basic and advanced modes of the audit, deviations up to ±6% are still tolerable, but new audit is repeated as soon as possible to solve the dosimetry problem. Deviations above ±6% leads immediately to investigation by EAG. There are 34 centers in the Czech Republic, which provide external beam radiotherapy. Since they must undergo the basic TLD audit regularly every

  10. Evaluation of the breast plan using the TLD and MOSFET for the skin dose

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Myeong; Kim, Young Bum; Bak, Sang Yun; Lee, Sang Rok; Jeong, Se Young [Dept. of Radiation Oncology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2015-12-15

    The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% - 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner' was highest in the MOSFET. Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay

  11. Development and evaluation of new semi-automatic TLD reader software

    International Nuclear Information System (INIS)

    Pathan, M.S.; Pradhan, S.M.; Palani Selvam, T.; Datta, D.

    2018-01-01

    Nowadays, all technology advancement is primarily focused on creating the user-friendly environment while operating any machine, also minimizing the human errors by automation of procedures. In the present study development and evaluation of new software for semi-automatic TLD badge reader (TLDBR-7B) is presented. The software provides an interactive interface and is compatible with latest windows OS as well as USB mode of data communication. Important new features of the software are automatic glow curve analysis for identifying any abnormality, event log register, user defined limits on TL count and time of temperature stabilization for readout interruption and auto reading resumption options

  12. Evaluation of the breast plan using the TLD and MOSFET for the skin dose

    International Nuclear Information System (INIS)

    Kim, Seon Myeong; Kim, Young Bum; Bak, Sang Yun; Lee, Sang Rok; Jeong, Se Young

    2015-01-01

    The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% - 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner' was highest in the MOSFET. Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay

  13. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G.

    2006-01-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  14. Interpretation of TLD data measured in the vicinity of nuclear power plants

    International Nuclear Information System (INIS)

    Czarnecki, J.; Baggenstos, M.; Schuler, J.; Voelkle, H.

    1981-01-01

    It is shown that incorporating the location-specific characteristics of natural radiation into the interpretation of the surrounding measurements makes some valuable contributions to the improvement of the measuring quality of thermoluminescent enviromental dosimetry. This brings the possibility to determine the net dose of the additional man-made radiations (e.g. caused by the nuclear power plant) with better accuracy. The authors propose a method of analysing the measured results which enables one to include the measured data from the evidence finding phase in the interpretation of the environment monitoring-TLD-measurement (orig./DG) [de

  15. Phosphorus fractions and sorption dynamics in the sediments of two Ca-SO4 water reservoirs in the central Argentine Andes

    Institute of Scientific and Technical Information of China (English)

    José Gabriel León; Fernando Luis Pedrozo; Pedro Félix Temporetti

    2017-01-01

    Phosphorus (P) fractionation and sorption behavior were studied in the sediments of two calcium-sulfate (Ca-SO4:Ca2+170 mg L-1;SO42-400 mg L-1) water reservoirs in the southern central Argentine Andes-El Carrizal Reservoir (ECR),which stratifies in summer and El Nihuil Reservoir (ENR),which is vertically mixed throughout the year. Sediment size classes reflected the lithology of both basins and the reservoirs relative location:ECR (downstream from a valley adjacent to a mountain environment) had higher clay proportions while the sand fraction was more important in ENR (just next to a mountain environment). In both reservoirs, the chemical composition revealed low alteration and calcium enrichment. Total P content was relatively high (1.1–1.6 mg P kg-1 dry weight) as expected from the contribution of marine formations. P fractionation was dominated by Ca-P (ECR, 69%and ENR, 63%) followed by organic-P (23%) in summer-anoxic ECR and by iron/aluminum (Fe/Al)-P (27%) in oxic ENR. Batch experiments showed that sorption behavior in ECR had a typical Langmuir isotherm plot while in ENR that model fitted only at low dissolved P values (<5 mg P L-1) and co-precipitation evidence was observed at higher P con-centrations. It is proposed that lower Fe/Al-P content in anoxic (ECR) vs. oxic (ENR) sediments results from the P released from iron-bound phosphorus due to sulfate reduction-ferrous sulfide formation in an anoxic environment. This condition should enable ECR sediments to adsorb P into fresh oxidized iron, and ENR sediments to co-precipitate P with calcium due to Fe/Al-P saturation, as observed in batch experiments. This paper constitutes the first description of phosphorus content and dynamics in reser-voir sediments in arid central western Argentina, where water sulfate concentrations are naturally high due to basin lithology.

  16. Magnetic properties of the ternary carbide DyCoC2 studied by magnetization measurements, neutron diffraction and 161Dy Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Amanai, H.; Onodera, H.; Ohashi, M.; Matsuo, S.; Yamauchi, H.

    1995-01-01

    The magnetic properties of DyCoC 2 have been investigated by means of magnetization measurements, powder neutron diffraction and 161 Dy Moessbauer spectroscopy. The magnetization versus temperature curves of a single-crystalline sample reveal that the magnetic structure of DyCoC 2 is a simple collinear ferromagnetic one below T C =10.0 K. At 4.2 K, the magnitude of the Dy moment is 8.7(1)μ B , whose direction is defined by an angle of 38.0(5) from the a-axis toward the c-axis. The magnetic structure and the magnitude of the moment are also confirmed by the results of powder neutron diffraction experiments and 161 Dy Moessbauer spectroscopy, respectively. ((orig.))

  17. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    Energy Technology Data Exchange (ETDEWEB)

    Bauk, Sabar, E-mail: sabar@usm.my [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hussin, Siti Fatimah [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Alam, Md. Shah [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Physics Department, Shahjalal University of Science and Technology, Sylhet (Bangladesh)

    2016-01-22

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peak 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.

  18. Resonant X-ray emission spectroscopy in Dy compounds

    International Nuclear Information System (INIS)

    Tanaka, Satoshi; Okada, Kozo; Kotani, Akio.

    1994-01-01

    The excitation spectrum of the L 3 -M 5 X-ray emission of Dy compounds in the pre-edge region of Dy L 3 X-ray absorption near edge structure (L 3 -XANES) is theoretically investigated based upon the coherent second order optical formula with multiplet coupling effects. The spectral broadening of the excitation spectrum is determined by the M 5 core hole lifetime, being free from the L 3 core hole lifetime. The fine pre-edge structure of the L 3 edge due to the 2p→4f quadrupole transition can be seen in the excitation spectrum, while this structure is invisible in the conventional XANES, in agreement with the recent experimental results. We clarify the conditions for the excitation spectrum to be regarded as the absorption spectrum with a smaller width. The resonant X-ray emission spectra for various incident photon energies around the L 3 edge are also calculated. (author)

  19. Some properties of commercial dyed plastic as radiation dosimeters

    International Nuclear Information System (INIS)

    Rageh, M.S.I.; El-Assy, N.B.; Ashry, M.

    1986-01-01

    The use of commercial dyed plastics (red and green perspex) as radiation dosimeters in a cobalt-60 sterilizing plant is described. The results are satisfactory and offer advantages over the other dosimeters. The increase in the optical density for red perspex at wavelengths 650 and 750 nm with radiation can be used for absorbed dose measurements over the ranges from 1 to 7.5 KGy and from 5 to 25 KGy correspondingly. The decrease in the optical density for green perspex at 596, 612 and 641 nm with absorbed dose can extend the linear response range up to about 45 KGy. The fading of intensity of the irradiation induced absorption bands in dyed plastics after storage at different temperatures had been investigated

  20. β-γ and isomeric decay spectroscopy of 168Dy

    Directory of Open Access Journals (Sweden)

    Zhang G.X.

    2018-01-01

    Full Text Available This contribution will report on the experimental work on the level structure of 168Dy. The experimental data have been taken as part of the EURICA decay spectroscopy campaign at RIBF, RIKEN in November 2014. In the experiment, a 238U primary beam is accelerated up to 345 MeV/u with an average intensity of 12 pnA. The nuclei of interest are produced by in-flight fission of 238U impinging on Be target with a thickness of 5 mm. The excited states of 168Dy have been populated through the decay from a newly identified isomeric state and via the β decay from 168Tb. In this contribution, scientific motivations, experimental procedure and some preliminary results for this study are presented.

  1. Hyperfine Structure and Isotope Shifts in Dy II

    Directory of Open Access Journals (Sweden)

    Dylan F. Del Papa

    2017-01-01

    Full Text Available Using fast-ion-beam laser-fluorescence spectroscopy (FIBLAS, we have measured the hyperfine structure (hfs of 14 levels and an additional four transitions in Dy II and the isotope shifts (IS of 12 transitions in the wavelength range of 422–460 nm. These are the first precision measurements of this kind in Dy II. Along with hfs and IS, new undocumented transitions were discovered within 3 GHz of the targeted transitions. These atomic data are essential for astrophysical studies of chemical abundances, allowing correction for saturation and the effects of blended lines. Lanthanide abundances are important in diffusion modeling of stellar interiors, and in the mechanisms and history of nucleosynthesis in the universe. Hfs and IS also play an important role in the classification of energy levels, and provide a benchmark for theoretical atomic structure calculations.

  2. β-γ and isomeric decay spectroscopy of 168Dy

    Science.gov (United States)

    Zhang, G. X.; Watanabe, H.; Kondev, F. G.; Lane, G. J.; Regan, P. H.; Söderström, P.-A.; Walker, P. M.; Kanaoka, H.; Korkulu, Z.; Lee, P. S.; Liu, J. J.; Nishimura, S.; Wu, J.; Yagi, A.; Ahn, D. S.; Alharbi, T.; Baba, H.; Browne, F.; Bruce, A. M.; Carroll, R. J.; Chae, K. Y.; Dombradi, Zs.; Doornenbal, P.; Estrade, A.; Fukuda, N.; Griffin, C.; Ideguchi, E.; Inabe, N.; Isobe, T.; Kanaya, S.; Kojouharov, I.; Kubo, T.; Kubono, S.; Kurz, N.; Kuti, I.; Lalkovski, S.; Lee, C. S.; Lee, E. J.; Lorusso, G.; Lotay, G.; Moon, C.-B.; Nishizuka, I.; Nita, C. R.; Odahara, A.; Patel, Z.; Phong, V. H.; Podolyák, Zs.; Roberts, O. J.; Sakurai, H.; Schaffner, H.; Shand, C. M.; Shimizu, Y.; Sumikama, T.; Suzuki, H.; Takeda, H.; Terashima, S.; Vajta, Zs.; Valiente-Dóbon, J. J.; Xu, Z. Y.

    2018-05-01

    This contribution will report on the experimental work on the level structure of 168Dy. The experimental data have been taken as part of the EURICA decay spectroscopy campaign at RIBF, RIKEN in November 2014. In the experiment, a 238U primary beam is accelerated up to 345 MeV/u with an average intensity of 12 pnA. The nuclei of interest are produced by in-flight fission of 238U impinging on Be target with a thickness of 5 mm. The excited states of 168Dy have been populated through the decay from a newly identified isomeric state and via the β decay from 168Tb. In this contribution, scientific motivations, experimental procedure and some preliminary results for this study are presented.

  3. Magnetoresistance anomaly in DyFeCo thin films

    International Nuclear Information System (INIS)

    Wu, J. C.; Wu, C. S.; Wu, Te-ho; Chen, Bing-Mau; Shieh, Han-Ping D.

    2001-01-01

    Microstructured rare-earth - transition-metal DyFeCo films have been investigated using magnetoresistance and extraordinary Hall-effect measurements. The Hall loops reveal variation of coercive fields depending on the linewidth and the composition of the films. The magnetoresistance curves, with changes up to as high as 1.3%, show positive/negative magnetoresistance peaks centered on the coercive fields depending on the linewidth of the films only. The variation of the coercivity can be attributed to the magnetic moment canting between the Dy and FeCo subcomponents and the existence of the diverged magnetization on the edges, and the anomalous magnetoresistance peaks observed are discussed with the existing theories. [copyright] 2001 American Institute of Physics

  4. Dosimetric behavior of thermoluminescent dosimeters at low doses in diagnostic radiology

    International Nuclear Information System (INIS)

    Del Sol F, S.; Garcia S, R.; Guzman M, J.; Sanchez G, D.; Rivera M, T.; Ramirez R, G.; Gaona, E.

    2015-10-01

    Thermoluminescent (Tl) characteristics of TLD-100, LiF:Mg,Cu,P, and CaSO 4 : Dy the under homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescent dosimetry is presented. The irradiations were performed utilizing an X-ray beam generated by a Radiology Mexican Company: MRH-II E GMX 325-AF SBV-1 model, with Rotating Anode X-Ray Tube installed in the Hospital Juarez Norte de Mexico in Mexico City. Different thermoluminescent characteristics of dosimetric material were studied, such as, batch homogeneity, Tl glow curve, Tl response as a function of X-ray dose, reproducibility and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and positioned in a generic Phantom was used. Dose verification and comparison with the measurements made with that obtained by TLD-100 were analyzed. Preliminary results indicate the dosimetric peak appears at 243, 236 and 277 ± 5 degrees C respectively, these peaks are in agreement with that reported in the literature. Tl glow curve as a function of X-ray dose showed a linearity in the range from 1.76 mGy up to 14.70 mGy for all materials. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO 4 : Dy. The results suggest that the three materials are suitable for measurements at low doses in radiodiagnostic, however, for its dosimetric characteristics are most effective for individual applications: personal dosimetry and monitors limb (LiF:Mg,Cu,P), clinical dosimetry and environmental (TLD-100 and CaSO 4 : Dy). (Author)

  5. Synthesis of CaF2: dy for thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Yamato, M.E.P.; Vasconcelos, D.A.A. de; Asfora, V.K.; Khoury, H.J.; Santos, R.A.; Barros, V.S.M.

    2015-01-01

    Calcium Fluoride doped with dysprosium is a known thermoluminescent material for applications that require highly sensitive dosimeters. Research in novel methods such as Combustion Synthesis (CS) has been ongoing for several years at the University of Pernambuco. The method uses the heat of the oxi-redox reaction a between nitrate and a fuel. This work presents results of CaF 2 :Dy produced by combustion synthesis under different fabrication conditions. Samples were prepared by mixing stoichiometric amounts of calcium nitrate, urea and ammonium nitrate in a beaker under vigorous stirring. The resulting gel was transferred to a pre-heated muffle furnace were the combustion reaction occurred after a few minutes. For comparison, a variation of the production method with the same amounts of nitrate, ammonium fluoride and dopant, but without using the fuel was prepared. For both methods the resulting powder was pelleted and irradiated with Co-60 gamma radiation. The reproducibility and sensitivity for gamma dose irradiation was tested and results showed that optimum TL sample reproducibility was without the urea as fuel. Samples were then prepared with 0.05, 0.10, 0.15 and 0.20 mol% Dy concentration. The highest TL sensitivity was found for samples with 0.15 mol% Dy and sintered at 400 deg C for 3.5 h in air. The TL emission spectra, obtained using a Hammamatsu optical spectrometer, was comparable with commercial CaF 2 :Dy. Thermoluminescence was measured in a Harshaw-Bicron 3500 TL Reader. The glow curve showed stable dosimetric peaks at around 200, 235 and 300 deg C were a linear dose response curve was obtained for the range 100 mGy to 1000 mGy. (author)

  6. Identical bands in Ba-Dy, N < 104 space

    International Nuclear Information System (INIS)

    Mittal, H.M.; Vidya Devi; Gupta, J.B.

    2008-01-01

    The recognition of the existence of identical bands, in even-even, odd-even and odd-odd nuclei, in normal deformed bands and superdeformed bands has become the subject of great interest in recent years. Here the search have been taken for such bands for the normal deformed, even-Z, even-N nuclei of Ba and Dy for 82< N<104 major shell space

  7. Coercivity enhancement in Nd-Fe-B sintered permanent magnet by Dy nanoparticles doping

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W.Q., E-mail: liuweiqiang77@hotmail.co [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China); Sun, H. [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China); Yi, X.F. [Anhui Earth-panda Advance Magnetic Material Co., Ltd., Anhui 231500 (China); Liu, X.C.; Zhang, D.T. [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China); Yue, M., E-mail: yueming@bjut.edu.c [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China); Zhang, J.X. [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China)

    2010-07-02

    Nd-Fe-B permanent magnets with a small amount of Dysprosium (Dy) nanoparticles doping were prepared by conventional sintered method, and the microstructure and magnetic properties of the magnets were studied. Investigation shows that the coercivity rises gradually, while the remanence decreases simultaneously with increased Dy doping amount. As a result, the magnet with 1.5 wt.% Dy exhibits optimal magnetic properties. Further investigation presumed that Dy is enriched as (Nd, Dy){sub 2}Fe{sub 14}B phase in the surface region of the Nd{sub 2}Fe{sub 14}B matrix grains indicated by the enhancement of the magneto-crystalline anisotropy field of the Nd{sub 2}Fe{sub 14}B phase. As a result, the magnet doped with a small amount of Dy nanoparticles possesses remarkably enhanced coercivity without sacrificing its magnetization noticeably.

  8. The ternary systems Sc-Sm(Dy)-Si at 870 K

    International Nuclear Information System (INIS)

    Kotur, B.Ya.; Mokra, I.Ya.; Toporinskij, A.Ya.

    1991-01-01

    Isothermal cross sections of the ternary systems Sc-Sm-Si and Sc-Dy-Si at 870 K have been plotted. Investigation of scandium and disprosium in ternary systems have been examined by X-ray diffraction and microstructure analysis. Besides literary data on binary systems Sc-Si, Sm-Si, Dy-Si have been used. Formation of limited (Sc-Sm-Si, Sc-Dy-Si) and continuous (Sc-Dy-Si) solid solutions based on bisilicides of Sc and Sm(Dy) is discovered. Two and five ternary compounds in Sc-Sm-Si and Sc-Dy-Si systems have been determined and their crystal structure has been established. When investigating of Sc-(rare earth element)-Si ternary systems and should take into account the specific interaction of scandium and samarium with REE

  9. Properties of alginate fiber spun-dyed with fluorescent pigment dispersion.

    Science.gov (United States)

    Wang, Ping; Tawiah, Benjamin; Tian, Anli; Wang, Chunxia; Zhang, Liping; Fu, Shaohai

    2015-03-15

    Spun-dyed alginate fiber was prepared by the spun-dyeing method with the mixture of fluorescent pigment dispersion and sodium alginate fiber spinning solution, and its properties were characterized by SEM, TGA, DSC, and XRD. The results indicate that fluorescent pigment dispersion prepared with esterified poly (styrene-alt maleic acid) had excellent compatibility with sodium alginate fiber spinning solution, and small amount of fluorescent pigment could reduce the viscosity of spun-dyed spinning solutions. SEM photo of spun-dyed alginate fiber indicated that fewer pigment particles deposited on its surface. TGA, DSC, and XRD results suggested that thermal properties and crystal phase of spun-dyed alginate fibers had slight changes compared to the original alginate fibers. The fluorescence intensity of spun-dyed alginate fiber reached its maximum when the content of fluorescent pigment was 4%. The spun-dyed alginate fiber showed excellent rubbing and washing fastness. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Magnetostrictive effects in ferromagnetic Dy break-junctions

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Marc; Suergers, Christoph; Montbrun, Richard [Karlsruher Institut fuer Technologie, Physikalisches Institut, 76131 Karlsruhe (Germany); Loehneysen, Hilbert v. [Karlsruher Institut fuer Technologie, Physikalisches Institut, 76131 Karlsruhe (Germany); Karlsruher Institut fuer Technologie, Institut fuer Festkoerperphysik, 76021 Karlsruhe (Germany)

    2011-07-01

    A characteristic property of the rare-earth metals are their large magnetostrictive strains which are related to the magnetocrystalline anisotropy through the elastic energy. We have investigated the electrical conductance G of mechanical break-junctions of a dysprosium wire at 4.2 K where Dy is in the ferromagnetic state. In zero magnetic field we find the usual variation of the conductance G vs. electrode distance x while breaking the wire mechanically, with a sequence of steps and more or less prominent plateaus. The behavior G(x) is modified in magnetic fields {mu}{sub 0} H up to 1 T due to the large magnetostriction of Dy. In addition, the conductance can be changed reproducibly by variation of H. For a number of contacts we observe discrete changes in G(H) in the range of several G{sub 0} = 2 e{sup 2}/h. The behavior of G(H) and its angular dependence can be quantitatively understood by taking into account the magnetostrictive properties of Dy. This first realization of a magnetostrictive atomic switch demonstrates the possibility of reproducibly tuning the conductance of magnetic nanocontacts by a magnetic field.

  11. New features in the spectrum of {sup 152}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Galindo-Uribarri, A; Andrews, H R; Ball, G C; Radford, D C; Janzen, V P; Ward, D [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.; Kuehner, J A; Mullins, S; Persson, L; Prevost, D; Waddington, J C [McMaster Univ., Hamilton, ON (Canada). Dept. of Physics; Drake, T E [Toronto Univ., ON (Canada). Dept. of Physics; Wyss, R [Joint Inst. for Heavy Ion Research, Oak Ridge, TN (United States)

    1992-08-01

    One of the most important recent developments in nuclear structure physics has been the prediction and observation of superdeformed (SD) shapes at high angular momentum in several nuclei in the rare earth region. The first experimental observation was a ridge-valley structure in a {gamma}-{gamma} coincidence matrix for the {sup 152}Dy nucleus. The ridge was found to be generated by sequences of stretched E2 transitions and corresponded to a moment of inertia J{sup (2)} of 85 {Dirac_h}{sup 2}MeV{sup -1}. Subsequently a discrete SD band was discovered in {sup 152}Dy and the lifetimes were measured. More recently the discovery of SD bands in several nuclei in the neighbourhood of {sup 152}Dy, the discovery of multiple SD bands in some nuclei, and the discovery of new SD regions at mass A {approx} 190 and A {approx} 140 have stimulated intense research activity in this area of nuclear physics. (author). 15 refs., 4 figs.

  12. Development of a TLD mailed system for remote dosimetry audit for 192Ir HDR and PDR sources

    International Nuclear Information System (INIS)

    Roue, Amelie; Venselaar, Jack L.M.; Ferreira, Ivaldo H.; Bridier, Andre; Dam, Jan van

    2007-01-01

    Background and purpose: In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. Materials and methods: A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from 192 Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an 192 Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1 s). Results: To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. Conclusion: A method of absorbed dose to water determination in the vicinity of an 192 Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The

  13. External assurance program in radiotherapy dose by TLD: implementation of a quality system and extension to complex treatments

    International Nuclear Information System (INIS)

    Mojsiejczuk, N.; Lohr, J.; Molina, L.; Vallejos, M.; Montaño, G.; Stefanic, A.; Zaretzky, A.

    2011-01-01

    Until now, the Regional Reference Center with secondary patterns for dosimetry ('Centro Regional de Referencia con Patrones Secundarios para Dosimetria' (CRRD)) has done dosimetry verifications with thermoluminescent dosimeters (TLD) in radiotherapy in square and rectangular fields. The objective of this paper is to inform about the first tests done to span new verification conditions in irradiations with multi-leaf collimator using regular and irregular field shapes. On the other hand, it will briefly describe the progress in the implementation of a quality management system adopted by the CRRD, regarding the TLD verification service. (author)

  14. Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources.

    Science.gov (United States)

    Roué, Amélie; Venselaar, Jack L M; Ferreira, Ivaldo H; Bridier, André; Van Dam, Jan

    2007-04-01

    In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from (192)Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an (192)Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1s). To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. A method of absorbed dose to water determination in the vicinity of an (192)Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The accuracy of the procedure was determined. This method allows a

  15. Effect of Ligand Substitution around the Dy(III) on the SMM Properties of Dual-Luminescent Zn-Dy and Zn-Dy-Zn Complexes with Large Anisotropy Energy Barriers: A Combined Theoretical and Experimental Magnetostructural Study.

    Science.gov (United States)

    Costes, Jean Pierre; Titos-Padilla, Silvia; Oyarzabal, Itziar; Gupta, Tulika; Duhayon, Carine; Rajaraman, Gopalan; Colacio, Enrique

    2016-05-02

    The new dinuclear Zn(II)-Dy(III) and trinuclear Zn(II)-Dy(III)-Zn(II) complexes of formula [(LZnBrDy(ovan) (NO3)(H2O)](H2O)·0.5(MeOH) (1) and [(L(1)ZnBr)2Dy(MeOH)2](ClO4) (3) (L and L(1) are the dideprotonated forms of the N,N'-2,2-dimethylpropylenedi(3-methoxysalicylideneiminato and 2-{(E)-[(3-{[(2E,3E)-3-(hydroxyimino)butan-2-ylidene ]amino}-2,2-dimethylpropyl)imino]methyl}-6-methoxyphenol Schiff base compartmental ligands, respectively) have been prepared and magnetostructurally characterized. The X-ray structure of 1 indicates that the Dy(III) ion exhibits a DyO9 coordination sphere, which is made from four O atoms coming from the compartmental ligand (two methoxy terminal groups and two phenoxido bridging groups connecting Zn(II) and Dy(III) ions), other four atoms belonging to the chelating nitrato and ovanillin ligands, and the last one coming to the coordinated water molecule. The structure of 3 shows the central Dy(III) ion surrounded by two L(1)Zn units, so that the Dy(III) and Zn(II) ions are linked by phenoxido/oximato bridging groups. The Dy ion is eight-coordinated by the six O atoms afforded by two L(1) ligands and two O atoms coming from two methanol molecules. Alternating current (AC) dynamic magnetic measurements of 1, 3, and the previously reported dinuclear [LZnClDy(thd)2] (2) complex (where thd = 2,2,6,6-tetramethyl-3,5-heptanedionato ligand) indicate single molecule magnet (SMM) behavior for all these complexes with large thermal energy barriers for the reversal of the magnetization and butterfly-shaped hysteresis loops at 2 K. Ab initio calculations on 1-3 show a pure Ising ground state for all of them, which induces almost completely suppressed quantum tunnelling magnetization (QTM), and thermally assisted quantum tunnelling magnetization (TA-QTM) relaxations via the first excited Kramers doublet, leading to large energy barriers, thus supporting the observation of SMM behavior. The comparison between the experimental and theoretical

  16. Unfolding neutron spectra obtained from BS–TLD system using genetic algorithm

    International Nuclear Information System (INIS)

    Santos, J.A.L.; Silva, E.R.; Ferreira, T.A.E; Vilela, E.C.

    2012-01-01

    Due to the variability of neutron spectrum within the same environment, it is essential that the spectral distribution as a function of energy should be characterized. The precise information allows radiological quantities establishment related to that spectrum, but it is necessary that a spectrometric system covers a large interval of energy and an unfolding process is appropriate. This paper proposes use of a technique of Artificial Intelligence (AI) called genetic algorithm (GA), which uses bio-inspired mathematical models with the implementation of a specific matrix to unfolding data obtained from a combination of TLDs embedded in a BS system to characterize the neutron spectrum as a function of energy. The results obtained with this method were in accordance with reference spectra, thus enabling this technique to unfold neutron spectra with the BS–TLD system. - Highlights: ► The unfolding code used the artificial intelligence technique called genetic algorithms. ► A response matrix specific to the unfolding data obtained with the BS–TLD system is used by the AGLN. ► The observed results demonstrate the potential use of genetic algorithms in solving complex nuclear problems.

  17. Measurements of environmental background radiation levels by TLD in and around the Jahangirnagar University Campus

    International Nuclear Information System (INIS)

    Mollah, A.S.; Aleya Begum; Idris Miah, M.; Yunus, Afrozi

    1997-01-01

    The background radiation levels at 30 locations in and around the Jahangirnagar University Campus (JUC) were measured using a LiF(TLD-100) thermoluminescent dosimeter (TLD). In addition, dose rates at three pre-selected locations were measured on a monthly as well as quarterly basis for one year period (July 1993 - June 1994). The dose rate ranges from 1016 to 2167 μSv.y -1 (101.6 to 216.7 mrem.y -1 ) with a mean value of 1595 μSv.y -1 (159.5 mrem.y -1 ). These values are comparable with those of pre- and post-operational values for the reactor site. The estimated average annual effective dose equivalent to the inhabitants at the study areas was found to be 1276 μSv (127.6 mrem). Variation of background radiation level with meteorological parameters, namely, temperature, rainfall, relative humidity and pressure was also studied. The influence on the dose rate of the meteorological parameters was observed. (author)

  18. The design philosophy for an automatic TLD system to meet current international specifications

    International Nuclear Information System (INIS)

    Haaslahti, J.

    1986-01-01

    The object of this paper is to describe the elements of a new automatic TLD system intended to meet draft IEC/ISO proposals and ANSI requirements in the USA. Dosemeter badge design is based on ICRU recommendations. The basic intent has been to produce a standard system that can measure and file raw data that can be adapted to specific user requirements with software. The system consists of a programmable automatic reader, an automatic irradiator, a computer, and dosemeters for environmental, whole body, extremity, and clinical applications. The reader uses hot nitrogen heating and photon counting, and measurement conditions may be chosen with complete freedom. The reader can produce a real-time glow curve to assist in checking performance. The irradiator has a 90 Sr- 90 Y source to permit programmed irradiation for calibration and material sensitivity checks. Cassettes are used to hold TLD cards during processing. Cassette coding both identifies samples and calls measurement parameters into use from memory. The system can be preprogrammed to measure all common materials and all common dosemeter elements (both square and round). (author)

  19. On the determination of the post-irradiation time from the glow curve of TLD-100

    International Nuclear Information System (INIS)

    Weinstein, M.; German, U.; Dubinsky, S.; Alfassi, Z.B.

    2003-01-01

    The ratio of peak 3 to the sum of peaks 4 + 5 in TLD-100 was measured for various pre-irradiation and post-irradiation time periods, under conditions characteristic of routine personal dosimetry. It was confirmed that the value of this ratio depends only on the elapsed time between the prior readout and the present one, independent of the moment when the irradiation took place during the total time interval (storage time). This effect indicates that fading of peak 3 seems to be due mainly to changes in the unoccupied traps, and not to decay of trapped charges, being almost independent of the presence of electrons or holes in the traps. This observation leads to the conclusion that the suggestions in the past to use the decay of peak 3 in TLD-100 for the measurement of the elapsed time between irradiation and readout may have been wrong. On the other hand, the decay of peak 2 can be used to measure the elapsed time from irradiation, since the rate of decay is different when related to pre-irradiation and post-irradiation times, indicating a much higher decay rate of the trapped charges (Randall-Wilkins decay). However, because of the fast decay rate of peak 2, its use for determination of the elapsed time since irradiation is of little practical significance. (author)

  20. Effects of Dy and Nb on the magnetic properties and corrosion resistance of sintered NdFeB

    International Nuclear Information System (INIS)

    Yu, L.Q.; Wen, Y.H.; Yan, M.

    2004-01-01

    Dy and Nb were added into the sintered NdFeB magnets with the aim of improving their magnetic properties and corrosion resistance. It was found that intrinsic coercivity of magnets is promoted whilst remanence is reduced as a result of Dy addition. Simultaneous addition of Dy and Nb not only gives rise to greatly improved coercivity, but also suppresses the undesirable effect of Dy on the remanence. The optimum magnetic properties were achieved when 1.0% Dy and 1.5% Nb were incorporated. Moreover, corrosion resistance of NdFeB magnets improves with the increase in the content of Dy and Nb

  1. Magnetooptic effects and Auger electron spectroscopy of two-layer NiFe-Dy and Fe-Dy films with nonuniform layers

    International Nuclear Information System (INIS)

    Ehdel'man, I.S.; Markov, V.V.; Khudyakov, A.E.; Ivantsov, R.D.; Bondarenko, G.V.; Ovchinnikov, S.G.; Kesler, V.G.; Parshin, A.S.; Ronzhin, I.P.

    2001-01-01

    Magneto-optical effects (magnetic circular dichroism and meridional Kerr effect) and element distribution with layer thickness in two-layer NiFe-Dy and Fe-Dy films, prepared by thermal sputtering of component in ultrahigh vacuum, are investigated. It is shown, that Dy in a two-layer film in the temperature range of 80-300 K makes constant contributions to both effects investigated which are approximately equal to the values of the effects observed in an isolated Dy film only at temperatures below the temperature T c of Dy transition into a ferromagnetic state (T c ∼ 100 K for the films under study). This behaviour of magneto-optical effects is assumed to be due to the influence of a NiFe layer spin system on magnetic state of a Dy layer, this influence is enhanced by the deep penetration of Ni and Fe ions into Dy layer as it follows from the data obtained using Auger electron spectroscopy [ru

  2. A Computerized QC Analysis of TLD Glow Curves for Personal Dosimetry Measurements Using TagQC Program

    International Nuclear Information System (INIS)

    Primo, S.; Datz, H.; Dar, A.

    2014-01-01

    The External Dosimetry Lab (EDL) at the Radiation Safety Division at Soreq Nuclear Research Center (SNRC) is ISO 17025 certified and provides its services to approximately 13,000 users throughout the country from various sectors such as medical, industrial and academic. About 95% of the users are monitored monthly for X-rays, and radiation using Thermoluminescence Dosimeter (TLD) cards that contain three LiF:Mg,Ti elements and the other users, who work also with thermal neutrons, use TLD cards that contain four LiF:Mg,Ti elements. All TLD cards are measured with the Thermo 8800pc reader.Suspicious TLD glow curve (GC) can cause wrong dose estimation so the EDL makes great efforts to ensure that each GC undergoes a careful QC procedure. The current QC procedure is performed manually and through a few steps using different softwares and databases in a long and complicated procedure: EDL staff needs to export all the results/GCs to be checked to an Excel file, followed by finding the suspicious GCs, which is done in a different program (WinREMS), According to the GC shapes (Figure 1 illustrates suitable and suspicious GC shapes) and the ratio between the elements result values, the inspecting technician corrects the data

  3. Response of TLD badge for the estimation of exposure conditions in diagnostic x-ray departments - use of lead aprons

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.; Bakshi, A.K.

    2002-01-01

    The present study was undertaken to ascertain the conditions of exposure of the TLD badge and to evaluate the inaccuracy involved in the estimation of dose received by the worker using an averaged lead apron transmission factor for the use of the badge above lead apron

  4. Malaysia Participation in the IAEA/ WHO TLD Postal Dose Quality Audit Service: Data Analysis From 2011-2015

    International Nuclear Information System (INIS)

    Norhayati Abdullah; Taiman Kadni

    2016-01-01

    In this paper, we report the dosimetry methodology used and the results of 22 Malaysian radiotherapy centres participated in the Thermoluminescent Dosimeter (TLD) Postal Dose Quality Audit Service organised by the International Atomic Energy Agency (IAEA) in collaboration with World Health Organisation (WHO) from 2011 to 2015. In this audit, a set of three capsules of TLD (encapsulated with Lithium Flouride powder) including a control TLD were sent to the participating centres for irradiation with 2 Gy of absorbed dose to water under reference condition. In this period, a total of 70 photon beams consists of 43 beams and 27 beams produced by 6 MV and 10 MV photon beams, respectively have been audited. The results demonstrated that all participating centres comply with the acceptance limits of ±5 % as recommended by the International Commission on Radiation Units and Measurements (ICRU) Report 24, except eight photon beams from six centres. However, these centres presented better compliance results after followed up with a second round of TLD irradiation. (author)

  5. Implementation of a self-directed work team in a TLD Processing Center

    International Nuclear Information System (INIS)

    Arnwine, A.A.; Bogard, R.S.; Teasley, N.A.; Somers, D.E.; Souleyrette, M.L.

    1994-01-01

    In an effort to maintain productivity with a decreasing work force, the Oak Ridge Y-12 Plant has adopted the concept of Self-Directed Work Teams in various disciplines. The plant's Health Physics Department was able to eliminate a layer of front-line supervisors by establishing four self-directed work teams. Each team was able to choose their method of implementation. The TLD Processing Center Team chose to use project managment tools to ensure a smooth transition from the traditional work group to a self-directed approach. This process focused on establishing responsibilities, determining training requirements, determining a leadership style for the group, and performing a potential problem analysis for the transition. The transition also reviewed interface issues that could occur with upper management, matrix management, technical oversight, and organizational peers. The team's experience is also evaluated in comparison to other Self-Directed Work Teams

  6. Performance and Test Results of Harshaw Pelletised LiF:Mg,Ti TLD Material

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Zhang, L.; Green, R.; Tomlins, P.

    1999-01-01

    BICRON NE has recently introduced a pelletised version of their popular TLD-100, 600 and 700 lithium fluoride based thermoluminescence dosemeters (TLDs). These materials can be used unmounted or in card and ring formats. Applications include whole-body, environmental, medical, and extremity monitoring. The former manufacturing process included purifying, growing doped LiF, grinding, blending, pressing, slicing, and dicing. The new process eliminates the last four steps, replacing them with a pelletising process. This process transforms the material directly from a powder to its final form. This new process provides the benefits of better batch uniformity and excellent dimensional consistency. The testing is described that was performed for the purpose of accepting the pelletised material as a directly interchangeable substitute for the same material produced by the former process. Tests performed include reproducibility, batch homogeneity, linearity, detection threshold, and light sensitivity. (author)

  7. A new TLD badge with machine readable ID for fully automated readout

    International Nuclear Information System (INIS)

    Kannan, S. Ratna P.; Kulkarni, M.S.

    2003-01-01

    The TLD badge currently being used for personnel monitoring of more than 40,000 radiation workers has a few drawbacks such as lack of on-badge machine readable ID code, delicate two-point clamping of dosimeters on an aluminium card with the chances of dosimeters falling off during handling or readout, projections on one side making automation of readout difficult etc. A new badge has been designed with a 8-digit identification code in the form of an array of holes and smooth exteriors to enable full automation of readout. The new badge also permits changing of dosimeters when necessary. The new design does not affect the readout time or the dosimetric characteristics. The salient features and the dosimetric characteristics are discussed. (author)

  8. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Av. Universidad 3000, 04510 DF (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com; García-Garduño, Olivia Amanda, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com [Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Av. Insurgentes Sur 3877, 14269 DF (Mexico)

    2014-11-07

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  9. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Science.gov (United States)

    Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.

    2018-03-01

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  10. TLD environmental monitoring at the Institute of Nuclear Engineering in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Taam, I.H. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Caixa Postal 68550, 21945-970 Rio de Janeiro, RJ (Brazil); Rosa, L.A.R. da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Av. Salvador Allende s/n, Caixa Postal 37760, 22780-160 Rio de Janeiro, RJ (Brazil)], E-mail: lrosa@ird.gov.br; Crispim, V.R. [PEN/COPPE-DNC/POLI/CT/UFRJ, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil)

    2008-09-15

    Since 2003 the Institute of Nuclear Engineering in Rio de Janeiro city, Brazil, operates a new cyclotron, RDS-111, to produce {sup 18}F-Fluorodeoxyglucose to be used in nuclear medicine. Additionally, the IEN radioactive waste repository has been enlarged during the past last years, receiving a considerable amount of radioactive materials. Therefore, it became necessary to evaluate a possible increase of the environmental gamma exposure rates at the institute site due to the operation of the new accelerator and the enlargement of the institute waste repository as well. LiF:Mg,Cu,P, TLD-100H, and TL detectors were employed for environmental kerma rate evaluation and the results were compared with previous results obtained before the RDS-111 operation initialisation and the enlargement of IEN waste repository. No significant contribution for the enhancement of environmental gamma kerma rates was detected.

  11. Nuclear accident dosimeter designed for use with the Panasonic TLD system

    International Nuclear Information System (INIS)

    Hankins, D.E.

    1985-01-01

    A new design for the nuclear accident dosimeter (NAD) compatible with the Panasonic TLD badge has recently been adopted for use at LLNL. This NAD was tested at the 1984 Oak Ridge National Laboratory Intercomparison of Criticality Accident Dosimeters study. We describe the procedures and constants developed to evaluate the NAD components. These constants were averaged to give reasonable results from bare and moderated spectra. Other procedures to evaluate a person's neutron dose using activation of the blood sodium and hair are described. These latter procedures are used to complement the dose determined using the NAD, or to determine a dose if a NAD had not been worn during exposure. If little is known about the configuration of the fissile material or shielding between the material and the exposed person, a procedure which combines the blood and hair activations gives a good estimate of the dose. (DT) 3 refs., 2 figs., 6 tabs

  12. Effect of temperatures up to 130 deg C on the responses of TLD 700

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, J A; Binns, P J [UKAEA Atomic Energy Research Establishment, Harwell. Environmental and Medical Sciences Div.

    1984-01-01

    The need to measure doses at temperatures up to 130 deg C led to an investigation into the effect of exposure and storage at these temperatures on the response of TLD 700 before and after UV phototransfer. As a preliminary, the delays required during the UV re-estimation process were optimised. The effects of storage and exposure were compared. This was followed by a detailed examination of the effects of storage at temperatures up to 130 deg C. Glow curves were analysed to investigate the rates of growth and decay of the different peaks. The findings for peaks 6 and 7 are compatible with previously reported effects at lower temperatures on peaks 3, 4 and 5. Storage at temperatures of 130 deg C or below for periods up to 28 days does not affect the UV photo-transfer response.

  13. Radiation doses measured by TLD (thermo luminescent dosimeter) in x-ray examination

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hiraki, Motoji; Murakami, Shozo; Nishikawa, Naozo; Yagi, Takayuki

    1977-01-01

    By means of TLD, we measured the radiation doses to the skin in the central area of the field of radiation and doses scattered outside of the radiation field, utilizing a phantom to define a suitable radiation field. Clinically, when radiography of the gall bladder and the chest was done, we measured both the radiation doses of the central skin area where radiation was done and the skin above the area of the female gonads. In radiography of the chest, the radiation doses to the skin area above the female gonads situate was under 0.1 mR. When female gonads are less than 15 cm from the margin of the radiation field of the radiation dose can be decreased by 30% if gum sheets containing lead are used to cover the skin area outside the radiation field. (auth.)

  14. A review of TLD's zero-count based on temperature and radiation history of them

    Science.gov (United States)

    Tunçel, Nina; Karakuş, İsmail; Dündar, Ertuğrul; Toykan Çiflikçi, Özlem

    2017-09-01

    In order to review the background value of a group of TLD-100, the zero-count values were collected from the first reading and after seven years after using them in experimental irradiations. The zero-counts for these two conditions were collected, as well as the dependence of temperature and radiation history of this group was evaluated. This study recommended that after frequently irradiation of TLDs the rearrangement for obtaining zero-count value must be performed before using TLDs in a new irradiation examination. Regarding on memory of radiation and thermal history, the sensitivity can change after receiving a large dose of radiation and undergoing readout. Additional annealing would be necessary to restore the original sensitivity. TLDs must be used under reproducible conditions to obtain consistent results.

  15. The cardiac catheterization laboratory personnel TLD dosimetry in Dr. Faghihi Hospital in Shiraz

    International Nuclear Information System (INIS)

    Derakhshan, Sh.

    2004-01-01

    In this study all of the personnel of Angiography of Dr.Faghihi hospital used TLD service During 2002-2003. This service was given by center for Radiation Protection and Application of the Shiraz University. These staff were divided in two group, one groups was technicians and the other group was the nurses. The result of this research shows that the maximum dose received to Technicians and nurses were 0.4mSv and 0.55mSV respectively. The average annual dose to technicians and nurses were 0.02 mSv and 0.19 mSv. This result shows that the nurses of this hospital receive more dose than the techniques

  16. Response of TLD-100 LiF dosimeters for X-rays of low energies

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.

    2011-10-01

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  17. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature

    International Nuclear Information System (INIS)

    Sagastibelza Chivite, F.

    1980-01-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs

  18. Evaluation of the kinetic parameters of CaF2:Tm (TLD-300) thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Azorin, Juan; Gutierrez, Alicia; Furetta, Claudio

    1989-01-01

    The kinetic parameters of the first, third and fifth peaks of CaF 2 :Tm (TLD-300) dosemeters were determined experimentally using methods based on initial rise, peak shape, different heating rates, isothermal decay and numerical fitting method and a comparison was made between the results obtained. The average activation energy values determined by the methods used here were 0.72, 1.16 and 1.77 eV, with mean values for the frequency factor of 2.58 x 10 8 , 2.89 x 10 13 and 6.16 x 10 16 s -1 for the first, third and fifth peaks respectively. The values of activation energy obtained for each peak using the different methods covered a spread of about 4%. However, the spread for each of the frequency factors was very high. (author)

  19. Evaluation of the exchange interaction and crystal fields in a prototype Dy2 SMM

    Science.gov (United States)

    Zhang, Qing; Sarachik, Myriam; Baker, Michael; Chen, Yizhang; Kent, Andrew; Pineda, Eufemio; McInnes, Eric

    In order to gain an understanding of the INS and magnetization data obtained for Dy2, the simplest member of a newly synthesized family of dysprosium-based molecular magnets, we report on calculations of the magnetic behavior of a Dy2 cluster with the formula [hqH2][Dy2(hq)4(NO3)3].MeOH. The molecular complex contains one high symmetry Dy(III) ion and one low symmetry Dy(III) ion. Our calculations suggest that exchange coupling between the two ions controls the behavior of the magnetization at low temperature, while the crystal field of the low symmetry Dy(III) ion controls the behavior at higher temperature. A point charge electrostatic model, based on crystallographic coordinates, provides a starting point for the determination of the crystal field. Parameters in these calculations are adjusted to provide best fits to inelastic neutron scattering data (INS) and low temperature magnetometry: the INS measurements access crystal field energies and low temperature magnetization probes the Dy-Dy exchange interaction. Work supported by ARO W911NF-13-1-1025 (CCNY) and NSF-DMR-1309202 (NYU).

  20. Synthesis, structure and magnetic properties of DyAl2 nanoparticles

    International Nuclear Information System (INIS)

    Zhang, W.S.; Brueck, E.; Zhang, Z.D.; Tegus, O.; Li, W.F.; Si, P.Z.; Geng, D.Y.; Klaasse, J.C.P.; Buschow, K.H.J.

    2006-01-01

    DyAl 2 nanoparticles have been prepared by means of arc discharge in a mixture of argon and hydrogen gas. The structure of DyAl 2 nanoparticles is studied by means of X-ray diffraction, X-ray photoelectron spectroscopy, and high-resolution transmission electron microscopy. X-ray photoelectron spectroscopy shows that the as-prepared DyAl 2 nanoparticles are coated with a layer of Al 2 O 3 phase on the surface, and their sizes vary from 20 nm to about 100 nm. The DyAl 2 nanoparticles exhibit ferromagnetic properties that are different from bulk DyAl 2 compound. The gradual decrease of the magnetization with increasing temperature in a wide temperature range reveals the size distribution of the DyAl 2 nanoparticles. The magnetic-entropy changes are derived from the isothermal magnetization curves measured at different temperatures. The magnetic-entropy change of the DyAl 2 nanoparticles is lower than that of the bulk DyAl 2 material but has a broadened peak

  1. Unfolding neutron spectra with BS-TLD system using genetic algorithms

    International Nuclear Information System (INIS)

    Santos, Joelan A.L.; Silva, Everton R.; Vilela, Eudice C.

    2011-01-01

    Due to the variability of neutron spectrum within the same environment, it is essential that the spectral distribution as function of energy to be characterized. To perform this task, the neutron spectrometer has a primary role in determining the neutron flux (Φ E (E)). Precise information allows radiological quantities establishment related to that spectrum but it is necessary, however, a series of steps with a spectrometric system that can cover a large interval of energy and whose answer is isotropic. The most widely used for accomplishing this task is the spectrometric Bonner spheres system. One of the biggest problems related to neutron spectrometry is the process of data analysis, known as unfolding. Most of the work undertaken to implement new techniques of this process, using data obtained with the scintillator 6 LiI(I). However, characteristics related to the dead time make it not be so effective when used in high flow neutron fields. An alternative to this problem is the use of thermoluminescent detectors (TLD), but the codes used do not provide a more specific response matrix to unfolding the information obtained through these materials, which makes the development of a specific response matrix important to adequately characterize the response obtained by them. This paper proposes using a technique of artificial intelligence called genetic algorithm, which uses bio-inspired mathematical models and through the implementation of a specific matrix to unfolding data obtained from a combination of TLDs embedded in a system of Bonner spheres, such as thermal neutron detectors, to characterize the neutron spectrum as a function of energy. The results obtained with this method were in accordance with reference spectra, thus enables of this technique to unfolding neutrons spectra with BS-TLD system. (author)

  2. Unfolding neutron spectra with BS-TLD system using genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joelan A.L., E-mail: jasantos@cnen.gov.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Silva, Everton R. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Centro de Informatica; Ferreira, Tiago A.E. [Universidade Federal Rural de Pernambuco (UFRPE), Recife, PE (Brazil). Dept. de Estatistica e Informatica; Fonseca, Evaldo S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Vilela, Eudice C., E-mail: ecvilela@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Due to the variability of neutron spectrum within the same environment, it is essential that the spectral distribution as function of energy to be characterized. To perform this task, the neutron spectrometer has a primary role in determining the neutron flux ({Phi}{sub E}(E)). Precise information allows radiological quantities establishment related to that spectrum but it is necessary, however, a series of steps with a spectrometric system that can cover a large interval of energy and whose answer is isotropic. The most widely used for accomplishing this task is the spectrometric Bonner spheres system. One of the biggest problems related to neutron spectrometry is the process of data analysis, known as unfolding. Most of the work undertaken to implement new techniques of this process, using data obtained with the scintillator {sup 6}LiI(I). However, characteristics related to the dead time make it not be so effective when used in high flow neutron fields. An alternative to this problem is the use of thermoluminescent detectors (TLD), but the codes used do not provide a more specific response matrix to unfolding the information obtained through these materials, which makes the development of a specific response matrix important to adequately characterize the response obtained by them. This paper proposes using a technique of artificial intelligence called genetic algorithm, which uses bio-inspired mathematical models and through the implementation of a specific matrix to unfolding data obtained from a combination of TLDs embedded in a system of Bonner spheres, such as thermal neutron detectors, to characterize the neutron spectrum as a function of energy. The results obtained with this method were in accordance with reference spectra, thus enables of this technique to unfolding neutrons spectra with BS-TLD system. (author)

  3. A TLD-based personal dosemeter system for air crew monitoring

    International Nuclear Information System (INIS)

    Hajek, M.; Berger, T.; Vana, N.

    2003-01-01

    Full text: Due to the complex spectrum of different particles and energies involved, in-flight radiation dosimetry is usually associated with extensive instrumentation. The exposure of air crew personnel to cosmic radiation is paid serious attention, being further enhanced by the release of the European Council Directive 96/29/Euratom which makes the surveillance of crew members an obligatory issue. The high temperature ratio (HTR) method for small and easy-to-handle LiF:Mg,Ti thermoluminescent dosimeters was developed at the Atomic Institute of the Austrian Universities and fulfils these demands by permitting the determination of dose equivalent in radiation fields of unknown composition. The method uses the relative intensity of glow peaks 6 and 7 compared with the dominant peak 5 in the LiF Tl emission as an indication for the average LET and, thus, the mean quality factor of the radiation field. Extensive experiments in various ion beams established a HTR vs. LET calibration curve for the commercially available Tl phosphors TLD-600 and TLD-700. Additionally, the different neutron sensitivity of both types may be exploited for the determination of the dose equivalent delivered from neutrons which dominate at aviation altitudes. However, it is essential that the calibration of the Tl detectors is performed in a neutron environment of similar spectral shape as that encountered in flight. In our case, this constraint was satisfied by the CERN-EU High-Energy Reference Field (CERF). Results of both neutron and total dose equivalent for several different north-bound and trans-equatorial routes are presented, ranging from 2.1 ± 0.1 μSv/h with a 30 % neutron contribution for Vienna-Sydney to 4.9 ± 0.2 μSv/h and a roughly 55 % neutron contribution for Vienna-Tokyo. The measured route doses are compared with CARI-6M calculations. (author)

  4. Measuring thermo-luminescence efficiency of TLD-2000 detectors to different energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wei Min; Chen, Bao Wei; Han, Yi; Yang, Zhong Jian [China Institute for Radiation Protection, Taiyuan (China)

    2016-06-15

    As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV {sup 137}Cs gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (η(E)). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply η(E), the η(E) can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of η(E) value, relative to 662 keV {sup 137}Cs gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. The η(E) values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

  5. QA Programme of the TLD laboratory of the University of Costa Rica: IEC 61066 testing

    International Nuclear Information System (INIS)

    Mora, Patricia; Porras Chaverria, Mariela

    2008-01-01

    The Thermoluminescence Personal Dosimetry Laboratory of the University of Costa Rica provides dose measurements for around 90% of occupational radiation workers in the country. The assessment of doses to workers routinely exposed to external sources of radiation constitutes an integral part of any radiation protection programme and helps national authorities to ensure acceptably safe and satisfactory radiological conditions in workplaces. Harshaw Readers Model 4000 and 4500, dosimeter holders Type 8814 with TLD-100 in 0110 cards and loose TLD-100 chips are used to monitor personal dose equivalent, Hp(10) and Hp(0.07). In order to provide a reliable measurement of the operational quantities, a study was undertaken to verify the fulfillment of international requirements in our system (Model 4500 with cards) against the Thermoluminescence dosimetry systems for personal and environmental monitoring CEI IEC 61066 (1991 -2012). The type tests performed were nine in total: batch homogeneity, reproducibility, linearity, detection threshold, effect of climate conditions on reader, effect of light exposure on dosimeters, isotropy, transient voltage and dropping on dosimeters. A Cesium-137 source was used to irradiate the dosimeters and all procedures follow the indications given on the standard. Results showed that all IEC criteria were met by our Laboratory. Acceptable uncertainties were also studied under the ICRP recommendations; the analysis of the Trumpet Curve was done with satisfactory results (for doses above 0.5 mSv; quotient of measure to real dose less than 3%). For purposes of accreditation (ISO/IEC 17025:2005) and performance testing this work is very relevant since the University of Costa Rica wants to establish a solid individual monitoring programme for external radiation exposure that will provide users, registrants, licensees and regulatory bodies with information that can be used for the optimization of protection and dose limitation of Costa Rican workers

  6. The energy response of CaF2:Dy

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Weiser, G.

    1982-11-01

    The energy response of CaF 2 :Dy was measured for 40-1250 keV photons and a very strong dependence was found below 200 keV. In order to fit the crystal to the requirements of the American Standards for Environmental Dosimetry, a number of filters which improve the energy dependence, were checked. It was found that the best filter is one which is made of 3 layers: tantalum, lead and aluminium, 0.018, 0.014 and 0.26 cm thick, respectively. (Author)

  7. High overexpression of dye decolorizing peroxidase TfuDyP leads to the incorporation of heme precursor protoporphyrin IX

    NARCIS (Netherlands)

    Colpa, Dana I.; Fraaije, Marco W.

    2016-01-01

    Highlights • Dye decolorizing peroxidase TfuDyP binds heme and protoporphyrin IX in vivo. • The activity of TfuDyP is dependent on the expression level in E. coli. • Expression of fully functional DyPs can be tuned by the type of expression host and expression conditions. The heterologous

  8. The IAEA/WHO TLD postal dose quality audits for radiotherapy: a perspective of dosimetry practices at hospitals in developing countries

    International Nuclear Information System (INIS)

    Izewska, Joanna; Andreo, Pedro; Vatnitsky, Stanislav; Shortt, Ken R.

    2003-01-01

    Background and purpose: The IAEA/WHO TLD postal programme for external audits of the calibration of high-energy photon beams used in radiotherapy has been in operation since 1969. This work presents a survey of the 1317 TLD audits carried out during 1998-2001. The TLD results are discussed from the perspective of the dosimetry practices in hospitals in developing countries, based on the information provided by the participants in their TLD data sheets. Materials and methods: A detailed analysis of the TLD data sheets is systematically performed at the IAEA. It helps to trace the source of any discrepancy between the TLD measured dose and the user stated dose, and also provides information on equipment, dosimetry procedures and the use of codes of practice in the countries participating in the IAEA/WHO TLD audits. Result: The TLD results are within the 5% acceptance limit for 84% of the participants. The results for accelerator beams are typically better than for Co-60 units. Approximately 75% of participants reported dosimetry data, including details on their procedure for dose determination from ionisation chamber measurements. For the remaining 25% of hospitals, who did not submit these data, the results are poorer than the global TLD results. Most hospitals have Farmer type ionisation chambers calibrated in terms of air kerma by a standards laboratory. Less than 10% of the hospitals use new codes of practice based on standards of absorbed dose to water. Conclusion: Despite the differences in dosimetry equipment, traceability to different standards laboratories and uncertainties arising from the use of various dosimetry codes of practice, the determination of absorbed dose to water for photon beams typically agrees within 2% among hospitals. Correct implementation of any of the dosimetry protocols should ensure that significant errors in dosimetry are avoided

  9. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  10. Coercivity enhancement in hot deformed Nd2Fe14B-type magnets by doping low-melting RCu alloys (R = Nd, Dy, Nd + Dy)

    Science.gov (United States)

    Lee, Y. I.; Huang, G. Y.; Shih, C. W.; Chang, W. C.; Chang, H. W.; You, J. S.

    2017-10-01

    Magnetic properties of the anisotropic NdFeB magnets prepared by hot pressing followed by die-upsetting NdFeB MQU-F powders doped with low-melting RCu alloy powders were explored, where RCu stands for Nd70Cu30, Dy70Cu30 and (Nd0.5Dy0.5)70Cu30, respectively. In addition, the post-annealing at 600 °C was employed to modify the microstructures and the magnetic properties of the hot deformed magnets. It is found that doping RCu alloy powders is effective in enhancing the coercivity of the hot deformed NdFeB magnets from 15.1 kOe to 16.3-19.5 kOe. For Nd70Cu30-doped magnets, the increment of coercivity is only 1.2 kOe. Meanwhile, Dy70Cu30-doped and (Nd0.5Dy0.5)70Cu30-doped magnets show an almost identical enhancement of coercivity of about 4.4 kOe. Importantly, the latter magnet shows a beneficial effect of reducing the usage of Dy from 1.6 wt% to 0.8 wt%. TEM analysis shows that nonmagnetic Nd, Dy and Cu appear at grain boundary and isolate the magnetic grains, leading to an enhancement of coercivity. Doping lower melting point Dy-lean (Nd0.5Dy0.5)70Cu30 powders into commercial MQU-F powders for making high coercivity hot deformed NdFeB magnets might be a potential and economic way for mass production.

  11. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A. M.; Saez, J. C

    1994-07-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  12. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A.M.; Saez, J.C.

    1994-08-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  13. Thermoluminescence in films of HfO2:Dy+3

    International Nuclear Information System (INIS)

    Ceron, P.; Rivera, T.; Guzman, J.; Montes, E.; Pelaez, A.; Rojas, B.; Guzman, D.; Azorin, J.; Paredes, L.

    2014-08-01

    In this work the thermoluminescence (TL) response of films of hafnium oxide polluted with dysprosium (HfO 2 :Dy +3 ) that were irradiated in the near UV (200 nm - 400 nm). The films were deposited by means of the ultrasonics spray pyrolysis technique on a glass substrate, using different deposit temperatures (300 grades C - 600 grades C). The best TL emission corresponded to the prepared film to 450 grades C that was exposed to a spectral irradiation of 80 μJ/(cm 2 -s) with a wave longitude of 240 nm. The TL response in function of the spectral irradiation was lineal in the studied interval (24 to 288 mJ/cm 2 ), several kinetic parameters were also calculated of the shine curve as depth of the trap (E), frequency factor (s) and order to the kinetics (b). The obtained results show that the films of HfO 2 :Dy +3 could be used as radiation monitor in the region of the near UV. (Author)

  14. Magnetic dipole excitations of the 163Dy nucleus

    Science.gov (United States)

    Zenginerler, Zemine; Tabar, Emre; Yakut, Hakan; Kuliev, Ali Akbar; Guliyev, Ekber

    2014-03-01

    In this study some properties of the magnetic dipole excitations of the deformed odd mass 163Dy nucleus were studied by using Quasiparticle-phonon nuclear model (QPNM). The several of the ground-state and low-lying magnetic dipole (M1) mode characteristics were calculated for deformed odd-mass nuclei using a separable Hamiltonian within the QPNM. The M1 excited states, reduced transition probabilities B(M1), the ground-state magnetic properties such as magnetic moment (μ), intrinsic magnetic moment (gK) , effective spin factor (gseff.) are the fundamental characteristics of the odd-mass nucleus and provide key information to understand nuclear structure. The theoretical results were compared with the available experimental data and other theoretical approaches. Calculations show that the spin-spin interaction in this isotopes leads to polarization effect influencing the magnetic moments. Furthermore we found a strong fragmentation of the M1 strength in 163Dy nucleus which was in qualitative agreement with the experimental data. Sakarya University, Project Number: 2012-50-02-007 and Z.Zenginerler acknowledge to TUBITAK-TURKEY 2013, fellowship No: 2219.

  15. Cytotoxic and genotoxic effect of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system in mice

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza-Lopez, Martha [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico); Ferro-Flores, Guillermina [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca, Ocoyoacac, Estado de Mexico, CP 52045 (Mexico); Arteaga de Murphy, Consuelo [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico)]. E-mail: consuelo_murphy@yahoo.com.mx; Morales-Ramirez, Pedro [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca, Ocoyoacac, Estado de Mexico, CP 52045 (Mexico); Piedras-Ross, Josefa [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico); Murphy-Stack, Eduardo [Hospital Santaelena, Mexico DF (Mexico); Hernandez-Oviedo, Omar [Escuela Superior de Fisica y Matematicas, IPN, Mexico DF (Mexico)

    2004-11-01

    Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. [{sup 166}Dy]Dy/{sup 166}Ho-ethylenediaminetetramethylene phosphonate (EDTMP) forms a stable in vivo generator system with selective skeletal uptake in mice; therefore, it could work as a potential and improved agent for marrow ablation. Induced bone marrow cytotoxicity and genotoxicity are determined by the reduction of reticulocytes (RET) and elevation of micronucleated reticulocyte (MN-RET) in peripheral blood and ablation by bone marrow histological studies. The aim of this study was to determine the bone marrow cytotoxic and genotoxic effect of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system in mice and to evaluate by histopathology its myeloablative potential. Enriched {sup 166}Dy{sub 2}O{sub 3} was irradiated and [{sup 166}Dy]DyCl{sub 3} was added to EDTMP in phosphate buffer (pH 8.0) in a molar ratio of 1:1.75. QC was determined by TLC. Dy-EDTMP complex was prepared the same way with nonirradiated dysprosium oxide. A group of BALB/c mice were intraperitoneally injected with the radiopharmaceutical and two groups of control animals were injected with the cold complex and with 0.9% sodium chloride, respectively. A blood sample was taken at the beginning of the experiments and every 48 h for 12 days postinjection. The animals were sacrificed, organs of interest taken out and the radioactivity determined. The femur was used for histological studies. Flow cytometry analysis was used to quantify the frequency of RET and MN-RET in the blood samples. The MCNP4B Monte Carlo computer code was used for dosimetry calculations. Radiochemical purity was 99% and the mean specific activity was 1.3 MBq/mg. The RET and MN-RET frequency were statistically different in the treatment at the end of the 12-day period demonstrating cytotoxicity and genotoxicity induced by the in vivo generator system. The

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  17. Comparison between indicators dosimetric released by teams and estimates by dosimetry TLD in the mammography of the Hospital Universitario 12 de Octubre

    International Nuclear Information System (INIS)

    Rot San Juan, M. J.; Martinez Gomez, L. C.; Gilarranz Moreno, R.; Milanes Gaillet, A. I.; Adaimi Hernandez, P.; Delgado rodriguez, J. M.

    2013-01-01

    With the incorporation of new technology, computers have indicators of dose for this magnitude. In this work we will compare to the mammography in our area the measure with the DSE TLD values thrown by the equipment. (Author)

  18. Magnetic and Moessbauer studies on GdCo3B2 and DyCo3B2

    International Nuclear Information System (INIS)

    Malik, S.K.; Umarji, A.M.; Shenoy, G.K.

    1984-10-01

    Magnetization and Moessbauer studies have been carried out on GdCo 3 B 2 and DyCo 3 B 2 . These compounds are magnetically ordered with Curie temperatures of 56 0 and 21 0 K respectively. The Co atoms are either nonmagnetic or carry a small moment in these compounds. The saturation moment of DyCo 3 B 2 at 5 0 K is smaller than the Dy 3+ free-ion value. From 161 Dy Moessbauer studies, the measured hyperfine magnetic field at the Dy site is also observed to be smaller than the free-ion value. 155 Gd Moessbauer measurements in GdCo 3 B 2 reveal the presence of large crystalline electric fields at the rare earth site. This causes the moment and the hyperfine field at the Dy site in DyCo 3 B 2 to be reduced from its free-ion value

  19. Enhanced ultraviolet photo-response in Dy doped ZnO thin film

    Science.gov (United States)

    Kumar, Pawan; Singh, Ranveer; Pandey, Praveen C.

    2018-02-01

    In the present work, a Dy doped ZnO thin film deposited by the spin coating method has been studied for its potential application in a ZnO based UV detector. The investigations on the structural property and surface morphology of the thin film ensure that the prepared samples are crystalline and exhibit a hexagonal crystal structure of ZnO. A small change in crystallite size has been observed due to Dy doping in ZnO. AFM analysis ascertains the grain growth and smooth surface of the thin films. The Dy doped ZnO thin film exhibits a significant enhancement in UV region absorption as compared to the pure ZnO thin film, which suggests that Dy doped ZnO can be used as a UV detector. Under UV irradiation of wavelength 325 nm, the photocurrent value of Dy doped ZnO is 105.54 μA at 4.5 V, which is 31 times greater than that of the un-doped ZnO thin film (3.39 μA). The calculated value of responsivity is found to increase significantly due to the incorporation of Dy in the ZnO lattice. The observed higher value of photocurrent and responsivity could be attributed to the substitution of Dy in the ZnO lattice, which enhances the conductivity, electron mobility, and defects in ZnO and benefits the UV sensing property.

  20. Physical and optical properties of lithium borosilicate glasses doped with Dy3+ ions

    Science.gov (United States)

    Ramteke, D. D.; Gedam, R. S.; Swart, H. C.

    2018-04-01

    The borosilicate glasses with Dy3+ ions were prepared by the melt quench technique with varying concentration of Dy2O3. The glasses were characterized by the density calculation, absorbance and photoluminescence (PL) spectroscopy measurements. Density and molar volume of the glasses increases with increase in Dy3+ ions in the glass matrix. This behavior is correlated with the higher molecular weight and larger ionic radius of Dy3+ ion compared to the other constituents of glass matrix. Emission of Dy3+ doped glasses showed three bands at 482, 573 and at 665 nm which correspond to 6H15/2 (blue), 6H13/2 (yellow) and 6H11/2 (red) transitions. The emission spectra of glasses with different concentration of Dy3+ ions shows that, glasses with 0.5 mol% of Dy2O3 shows highest emission and decreases with further doping. CIE 1931 chromaticity diagram showed that the emission of these glasses was in the white region. Photographs of these glasses under 349 nm Light emitting diode excitation also confirmed the white light emission from these glasses.

  1. Fabrication, magnetostriction properties and applications of Tb-Dy-Fe alloys: a review

    Directory of Open Access Journals (Sweden)

    Nai-juan Wang

    2016-03-01

    Full Text Available As an excellent giant-magnetostrictive material, Tb-Dy-Fe alloys (based on Tb0.27-0.30Dy0.73-0.70Fe1.9-2 Laves compound can be applied in many engineering fields, such as sonar transducer systems, sensors, and micro-actuators. However, the cost of the rare earth elements Tb and Dy is too high to be widely applied for the materials. Nowadays, there are two different ways to substitute for these alloying elements. One is to partially replace Tb or Dy by cheaper rare earth elements, such as Pr, Nd, Sm and Ho; and the other is to use non-rare earth elements, such as Co, Al, Mn, Si, Ce, B, Be and C, to substitute Fe to form single MgCu2-type Laves phase and a certain amount of Re-rich phase, which can reduce the brittleness and improve the corrosion resistance of the alloy. This paper systemically introduces the development, the fabrication methods and the corresponding preferred growth directions of Tb-Dy-Fe alloys. In addition, the effects of alloying elements and heat treatment on magnetostrictive and mechanical properties of Tb-Dy-Fe alloys are also reviewed, respectively. Finally, some possible applications of Tb-Dy-Fe alloys are presented.

  2. Mean field analysis of exchange coupling in amorphous DyFe2-B alloy ribbons

    International Nuclear Information System (INIS)

    Lee, J.M.; Jung, J.K.; Lim, S.H.

    2001-01-01

    Experimental magnetization-temperature curves for melt-spun ribbons of amorphous alloys (Dy 0.33 Fe 0.67 ) 1-x B x with x=0, 0.05, 0.1 and 0.15 (in atomic fraction) are fitted with theoretical equations based on the mean field theory in order to investigate exchange couplings between constituent elements as a function of the B content. The sign of the exchange coupling between Dy and Fe is negative, indicating that the magnetization direction of Dy is antiparallel to that of Fe. The sign of the other two couplings are positive. The exchange coupling between Fe ions are greatest, while that between Dy ions is negligible. The exchange couplings between Fe ions, and between Dy and Fe increase with increasing B content, the increase of the latter being much greater than the former. Resulting, the exchange coupling between Dy and Fe becomes about one half of that between Fe ions at the highest B content. The increase of the exchange coupling between Fe ions may be explained by the increase of the Fe-Fe separation with the increase of the B content. The total magnetization is dominated by the Dy sublattice magnetization. As the B content increases, the magnetization decreases over the whole temperature range, and the Curie temperature also decreases

  3. Co-precipitation synthesis of YAG:Dy nanophosphor and its thermometric properties

    International Nuclear Information System (INIS)

    Chong, Joo-Yun; Zhang, Yuelan; Wagner, Brent K.; Kang, Zhitao

    2013-01-01

    Highlights: •YAG:Dy nanophosphors were synthesized with particle size of about 50 nm. •Optimized doping concentration of 6%Dy was determined. •Thermometric photoluminescence properties were studied between 20 and 350 °C. •Temperature-sensitive change in peak ratio of 496/457 nm emissions was demonstrated. •Suitable for potential thermographic applications when dispersed in a liquid media. -- Abstract: Dy 3+ doped yttrium aluminum garnet (YAG) nanophosphors were synthesized by a co-precipitation method for potential thermographic applications in a liquid media dispersed with fluorescent nanoparticles. The doping concentration and annealing temperature on the structural and optical properties of YAG:Dy were investigated. Pure phase YAG:Dy nanophosphors were obtained by annealing the co-precipitated hydroxide products at above 900 °C. Maximum photoluminescence intensity was observed from 6%Dy doped YAG samples. The effect of measuring temperature between 20 and 350 °C on the photoluminescence spectra of nano YAG:Dy was investigated. A temperature-sensitive change in the peak intensity ratio of 496/457 nm emission lines was demonstrated for such nanophosphors for the first time, suggesting potential applications in temperature monitoring of fuel spray

  4. Co-precipitation synthesis of YAG:Dy nanophosphor and its thermometric properties

    Energy Technology Data Exchange (ETDEWEB)

    Chong, Joo-Yun [School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Zhang, Yuelan [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Wagner, Brent K. [Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Kang, Zhitao, E-mail: zhitao.kang@gtri.gatech.edu [Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, GA 30332 (United States); School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2013-12-25

    Highlights: •YAG:Dy nanophosphors were synthesized with particle size of about 50 nm. •Optimized doping concentration of 6%Dy was determined. •Thermometric photoluminescence properties were studied between 20 and 350 °C. •Temperature-sensitive change in peak ratio of 496/457 nm emissions was demonstrated. •Suitable for potential thermographic applications when dispersed in a liquid media. -- Abstract: Dy{sup 3+} doped yttrium aluminum garnet (YAG) nanophosphors were synthesized by a co-precipitation method for potential thermographic applications in a liquid media dispersed with fluorescent nanoparticles. The doping concentration and annealing temperature on the structural and optical properties of YAG:Dy were investigated. Pure phase YAG:Dy nanophosphors were obtained by annealing the co-precipitated hydroxide products at above 900 °C. Maximum photoluminescence intensity was observed from 6%Dy doped YAG samples. The effect of measuring temperature between 20 and 350 °C on the photoluminescence spectra of nano YAG:Dy was investigated. A temperature-sensitive change in the peak intensity ratio of 496/457 nm emission lines was demonstrated for such nanophosphors for the first time, suggesting potential applications in temperature monitoring of fuel spray.

  5. Study of thermoluminescence emissions of dosimetric phosphors; the detection of intermediate neutrons

    International Nuclear Information System (INIS)

    Santos, E.N. dos.

    1979-01-01

    Thermally stimulated luminescence (TSL) studies have been carried out in cold-pressed CaSO 4 +DY 2 O 3 +KCl (specimen 1) and natural CaF 2 +DY 2 O 3 + KCl (specimen 2) polycrystaline samples. The ratios of the TSL sensivities of specimens 1 and 2 relative to that of 6 LiF:Mg;Ti (TLD-600) are found to be 24 and 3, respectively. The minimum detectable neutron fluence has been determined to be approximately 3.5X10 5 n/cm 2 . The determination of the effective half-life of the TSL emission lead to the identification of the isotope responsible for the self-irradiation of the specimens: 165 66 DY. (F.E.) [pt

  6. Mechanical properties, corrosion, and biocompatibility of Mg-Zr-Sr-Dy alloys for biodegradable implant applications.

    Science.gov (United States)

    Ding, Yunfei; Lin, Jixing; Wen, Cuie; Zhang, Dongmei; Li, Yuncang

    2017-11-28

    This study investigates the microstructure, mechanical properties, corrosion behavior, and biocompatibility of magnesium (Mg)-based Mg1Zr2SrxDy (x = 0, 1, 1.63, 2.08 wt %) alloys for biodegradable implant applications. The corrosion behavior of the Mg-based alloys has been evaluated in simulated body fluid using an electrochemical technique and hydrogen evolution. The biocompatibility of the Mg-based alloys has been assessed using SaSO2 cells. Results indicate that the addition of Dy to Mg-Zr-Sr alloy showed a positive impact on the corrosion behavior and significantly decreased the degradation rates of the alloys. The degradation rate of Mg1Zr2Sr1.0Dy decreased from 17.61 to 12.50 mm year -1 of Mg1Zr2Sr2.08Dy based on the hydrogen evolution. The ultimate compressive strength decreased from 270.90 MPa for Mg1Zr2Sr1Dy to 236.71 MPa for Mg1Zr2Sr2.08Dy. An increase in the addition of Dy to the Mg-based alloys resulted in an increase in the volume fraction of the Mg 2 Dy phase, which mitigated the galvanic effect between the Mg 17 Sr 2 phase and the Mg matrix, and led to an increase in the corrosion resistance of the base alloy. The biocompatibility of the Mg-based alloys was enhanced with decreasing corrosion rates. Mg1Zr2Sr2.08Dy exhibited the lowest corrosion rate and the highest biocompatibility compared with the other Mg-based alloys. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.

  7. TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects

    CERN Document Server

    Sabini, M G; Cuttone, G; Guasti, A; Mazzocchi, S; Raffaele, L

    2002-01-01

    In this work, the dose response of TLD-100 dosimeters has been studied in a 62 MeV clinical proton beams. The signal versus dose curve has been compared with the one measured in a sup 6 sup 0 Co beam. Different experiments have been performed in order to observe the thermal stress and the radiation damage effects on the detector sensitivity. A LET dependence of the TL response has been observed. In order to get a physical interpretation of these effects, a computerised glow-curve deconvolution has been employed. The results of all the performed experiments and deconvolutions are extensively reported, and the TLD-100 possible fields of application in the clinical proton dosimetry are discussed.

  8. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  9. An approach to an analysis of the energy response of LiF-TLD to high energy electrons

    International Nuclear Information System (INIS)

    Shiragai, A.

    1977-01-01

    Responses of LiF-TLD to high energy electrons relative to 60 Co γ-rays were investigated experimentally and theoretically. The Burlin et al. theory (Burlin, T.E., Snelling, R.J., and Owen, B., 1969, in Proc.2nd Symp. on Microdosimetry, Stresa, Italy; Brussels: Commission of European Communities; p.455), its modified version by Almond and McCray (Almond, P.R., and McCray, K., 1970, Phys.Med.Biol., vol.15, 335 and 746) and the Holt et al. semi-empirical theory (Holt, J.G., Edelstein, G.R., and Clark, T.E., 1975, Phys.Med.Biol., vol.20, 559) were examined in comparison with each experiment. An approximate approach to theoretical analysis of energy response of LiF-TLD was attempted and compared with some experimental results. (author)

  10. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  11. Personnel photon dosimeter on the base of TLD sup n sup a sup t LiF

    CERN Document Server

    Kaskanov, G Y

    2003-01-01

    A personnel photon dosemeter on the basis of thermoluminescence detectors (TLD) sup n sup a sup t LiF is described. Experimental responses of the dosemeters in the unit of individual equivalent dose H sub p (10) for energy of photons 59.5, 120, 662, and 1250 keV are presented. It is shown that the dosemeter allows one to measure H sub p (10) with admissible uncertainty in the energy range from 60 to 1250 keV.

  12. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  13. Determination of Antimicrobial Activity of the Dyed Silk Fabrics with Some Natural Dyes

    OpenAIRE

    ALKAN, Rezan; TORGAN, Emine; AYDIN, Canan; KARADAG, Recep

    2015-01-01

    In this study, silk fabric is dyed with natural indigo. Dyed silk fabric with natural indigo was cut in the 20x20 cm2 size. Excluding a fabric, all fabrics were mordanted in the same percentage with alum metal (KAl(SO4)2.12H2O). Then, silk fabrics for green color dyeing are dyed separately with weld (Reseda luteola), gall oak (Quercus infectoria Olivier) and together weld (Reseda luteola) and gall oak (Quercus infectoria) in different percentage. Antimicrobial functionality of the twenty seve...

  14. Epitaxial growth and new phase of single crystal Dy by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Yang, Kai-Yueh; Homma, Hitoshi; Schuller, I.K.

    1987-09-01

    We have grown two novel epitaxial phases of dysprosium (Dy) on vanadium (V) by molecular beam epitaxy technique. Surface and bulk structures are studied by in-situ reflection high energy electron diffraction (RHEED) and x-ray diffraction techniques. The new hcp phases are ∼4% expanded uniformly in-plane (0001), and ∼9% and ∼4% expanded out of plane along the c-axes for non-interrupted and interrupted deposition case, respectively. We also observed (2 x 2), (3 x 3), and (4 x 4) Dy surface reconstruction patterns and a series of transitions as the Dy film thickness increases. 12 refs., 3 figs

  15. Magnetic exchange coupling in amorphous Fe80-xDy xB20 alloys

    International Nuclear Information System (INIS)

    Annouar, F.; Lassri, H.; Ayadi, M.; Omri, M.; Lassri, M.; Krishnan, R.

    2005-01-01

    Amorphous Fe 80-x Dy x B 20 alloys have been prepared by melt spinning and their magnetic properties have been studied. The mean field theory has been used to explain the temperature dependence of the magnetization. The exchange interactions between Co-Co and Dy-Co atom pairs have been evaluated. High-field magnetization studies on samples with stoichiometry close to that of a compensated ferrimagnet show a magnetic behavior that is characteristic of a non-collinear magnetic structure of the Dy and Fe sublattices. The region of the canted moments can be described by a phase diagram in the H-T plane

  16. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  17. Test of an albedo neutron dosimetry system: TLD calibration and readout procedure, neutron calibration, dosimetry properties, routine application

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1988-03-01

    The two-component albedo dosemeter in use consists of an universal boron-loaded plastic encapsulation, the beta and albedo neutron windows of which are adopted to the corresponding TLD system of the manufacturers Alnor, Harshaw, Panasonic and Vinten. Beside the TLD detectors the capsule may contain also track etch detectors. Within a BMU project the system was investigated by four governmental measurement services in the FRG with respect to its qualification for personnel monitoring with emphasis in the readout and calibration procedures for the TLD system, the evaluation technique for the estimation of the photon and neutron dose equivalent in routine monitoring and the calibration of the personnel dosemeter in stray neutron fields. The test has shown the readiness of the system to act in the application areas of nuclear power reactors and linacs behind heavy shieldings, in the fuel element cycle, use of fissile materials, criticality, use of radionuclide sources, high energy particle accelerators. The uncertainty due to energy dependence was found to be within a factor of 2 for a single application area. In the case of irradiations from the front half space the dose equivalent H'(10) is indicated sufficiently independent of the direction of the radiation incidence. After completion of the test the albedo dosemeter became the official neutron personnel dosemeter in the FRG. It allows the separate estimation of the dose equivalent of hard beta radiation, photon radiation and neutrons. (orig./HP) [de

  18. A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand

    International Nuclear Information System (INIS)

    Si, Fenni; Yang, Jianlun; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Ye, Fan; Wang, Dong; Zhang, Chuanfei

    2017-01-01

    Highlights: • A Pb-TLD spectrometer has been developed to measure spectra of high energy photons in wire-array z pinches on PTS. • Energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code. • The energy of high energy x-ray on PTS is obtained to be mainly within the region of 100 keV to 1.3 MeV. - Abstract: A Pb-TLD spectrometer has been developed based on attenuation techniques to measure high energy photons in wire-array z-pinch experiments on the primary test stand (PTS). It is composed of a stack of 18 lead filters interspersed with 19 thermoluminescent dosimeters (TLD). A shield is constructed for the spectrometer and scattered radiation is reduced to less than 5% by the shield. Response functions of the spectrometer are calculated by MCNP5 for 0–2 MeV photons. Based on response functions and 19 dose data measured in experiments, energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code using iterative least square fit. Results show that energy peak locates within 200 keV and 300 keV, and the fluence decreases to background level at energy higher than 1.3 MeV.

  19. In-vivo dosimetry in radiotherapy: a comparison of the response of semiconductor and thermoluminescence (TLD700) dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Vynckier, S [Universite Catholique de Louvain, Brussels (Belgium). Cliniques Universitaires St. Luc; Greffe, J L; Loncol, T; Vanneste, F; Octave-Prignot, M; Denis, J M; De Patoul, N

    1995-12-01

    Semiconductor dosemeters and thermoluminescence dosemeters were calibrated in view of in-vivo dosimetry. Their response in a 8 MV photon beam and the respective correction factors for the treatment conditions were systematically studied. A total of 249 entrance and exit measurements with this dual detector combination were performed, mainly for treatments of the head and neck region. The resulting entrance and exit doses were compared with the expected doses at these positions, calculated on basis of the treatment and patient parameters. The results at the entrance showed a value of 1.010 (2.8% for the ratio of the measured to the calculated dose by diodes, 1.013) 4.9% for the ratio of the measured to the calculated dose by TLD and 1.003 (3.6% for the ratio of the measured dose by TLD to diodes. With respect the exit dose, the results were 0.998) 4.9%, 1.016 (7.7% and 1.019) 7.0% respectively after correction for the heterogeneity`s. Although the standard deviation for the TLD dosemeters is systematically larger than the standard deviation for the diodes, it is concluded that both dosemeters will yield similar results for-in-vivo dosimetry, if utilized under the same conditions.

  20. A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Si, Fenni; Yang, Jianlun; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Ye, Fan; Wang, Dong; Zhang, Chuanfei, E-mail: sifenni@163.com

    2017-05-15

    Highlights: • A Pb-TLD spectrometer has been developed to measure spectra of high energy photons in wire-array z pinches on PTS. • Energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code. • The energy of high energy x-ray on PTS is obtained to be mainly within the region of 100 keV to 1.3 MeV. - Abstract: A Pb-TLD spectrometer has been developed based on attenuation techniques to measure high energy photons in wire-array z-pinch experiments on the primary test stand (PTS). It is composed of a stack of 18 lead filters interspersed with 19 thermoluminescent dosimeters (TLD). A shield is constructed for the spectrometer and scattered radiation is reduced to less than 5% by the shield. Response functions of the spectrometer are calculated by MCNP5 for 0–2 MeV photons. Based on response functions and 19 dose data measured in experiments, energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code using iterative least square fit. Results show that energy peak locates within 200 keV and 300 keV, and the fluence decreases to background level at energy higher than 1.3 MeV.

  1. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  2. The assessment of personal dose due to external radiation

    International Nuclear Information System (INIS)

    Boas, J.F.; Young, J.G.

    1990-01-01

    The fundamental basis of thermoluminescent dosimetry (TLD) is discussed and a number of considerations in the measurement of thermoluminescence described, with particular reference to CaSO 4 :Dy. The steps taken to convert a thermoluminescence measurement to an exposure and then an absorbed dose are outlined. The calculation of effective dose equivalents due to external exposure to γ-radiation in a number of situations commonly encountered in a uranium mine is discussed. Factors which may affect the accuracy of external dose assessments are described

  3. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  4. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  5. Ambient radiation levels in a microPET/CT research laboratory

    International Nuclear Information System (INIS)

    Sarmento, D.M.; Rodrigues, D.L.; Sanches, M.P.; Carneiro, J.C.G.G.

    2015-01-01

    This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLD, of CaSO 4 :Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring. (author)

  6. Field-induced transitions in DySb

    International Nuclear Information System (INIS)

    Brun, T.O.; Lander, G.H.; Korty, F.W.; Kouvel, J.S.

    1974-01-01

    The NaCl-structured compound DySb, which in zero field transforms abruptly at T/sub N/ approximately 9.5 0 K to a Type-II antiferromagnetic (A) state with a nearly tetragonal lattice distortion, was previously found to exhibit rapid field-induced changes in magnetization at 1.5 0 K. The field-induced transitions in a DySb crystal have been studied by neutron diffraction and magnetization measurements in fields up to approximately 60 kOe applied parallel to each of the principal axes. In the broken bracket 100 broken bracket case, the transition from the A to an intermediate ferrimagnetic (Q) state is first-order at 4.2 0 K (critical field H/sub c/ approximately 21 kOe) but is continuous from approximately 6 0 K up to T/sub N/: as H/sub c/ → 0. The Q-to-paramagnetic (P) transition is rapid but continuous at 4.2 0 K (H/sub c/ approximately 40 kOe) and becomes broad as T/sub N/ is approached. In the broken bracket 110 broken bracket case the A-to-Q transition remains essentially first-order from 4.2 0 K (H/sub c/ approximately 15 kOe) up to T/sub N/; above T/sub N/ rapid P-to-Q transitions occur at very high fields. The magnetic structure of the Q state is found to be that of HoP. (U.S.)

  7. Status of services, overexposure and QAC in TLD PMS to defence

    International Nuclear Information System (INIS)

    Rathore, A.S.; Gupta, D.K.; Samaria, H.C.; Chouhan, R.L.; Mishra, M.; Goyal, J.K.; Gautam, M.; Kalla, R.

    2008-01-01

    Individual monitoring has always played an important role in radiological protection. There is continuous development in the field of dosimetry systems and many changes have taken place in last many years. The use of radiation for peaceful purposes is increasing with advancement of technological growth in the country. Thermo luminescence dosimeters (TLDs) have emerged as one of the best alternatives for personal monitoring. Defence sector has nearly 2100 persons, who are working in various Military Hospitals, Military Colleges, DRDO Labs, Defence Ordinance factories and many others CPMFs like CISF, BSF, who are likely to receive radiation doses. Defence Laboratory, Jodhpur is providing the TLD personal monitoring service since Jan 1999 as per the guideline by B.A.R.C. to all the institutions mentioned above. This paper brings out salient features of this service in terms of facility available, procedures fulfilling the requirement of accreditation, over exposure reported, quality measures adopted and quality assurance results conducted by BARC, utility and suggestions for such type of services. (author)

  8. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  9. Systematical and statistical errors in using reference light sources to calibrate TLD readers

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Piesch, E.

    1981-01-01

    Three light sources, namely an NaI(Tl) scintillator + Ra, an NaI(Tl) scintillator + 14 C and a plastic scintillator + 14 C, were used during a period of 24 months for a daily check of two TLD readers: the Harshaw 2000 A + B and the Toledo 651. On the basis of light source measurements long-term changes and day-to-day fluctuations of the reader response were investigated. Systematical changes of the Toledo reader response of up to 6% during a working week are explained by nitrogen effects in the plastic scintillator light source. It was found that the temperature coefficient of the light source intensity was -0.05%/ 0 C for the plastic scintillator and -0.3%/ 0 C for the NaI(Tl) scintillator. The 210 Pb content in the Ra activated NaI(Tl) scintillator caused a time-dependent decrease in light source intensity of 3%/yr for the light source in the Harshaw reader. The internal light sources revealed a relative standard deviation of 0.5% for the Toledo reader and the Harshaw reader after respective reading times of 0.45 and 100 sec. (author)

  10. Measurement of dose to skin using TLD of several radiodiagnostic studies in San Jose, Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.

    1998-01-01

    It is quantified the radiation doses on skin for several radiodiagnostic studies in patients of the Calderon Guardia Hospital in San Jose, Costa Rica at the period October 1997-September 1998 using thermoluminescent dosemeters TLD 100. The crystals receive the decoction standard procedures and they are arranged at the middle of the irradiation field. For a total of 973 radiodiagnostic studies it was found that the dose on skin in mGy are: 2.09 for thorax AP/AP, 5.33 for thorax LAT, 5.35 for skull AP/PA, 2.98 for skull LAT, 10.74 for abdomen, hips and pelvis, 6.20 for spines AP, 9.35 for spines LAT, 11.48 for lumbar columns AP, 29.99 for lumbar columns LAT and 6.87 for intravenous skin diagrams (first plate ap). It is produced thus the first reference bank for the national hospitals, which is compared with the orientation levels of doses for IAEA. Recommendations to diminish the collective doses through quality control programs are discussed, taking as goal to have got radiographs of excellent diagnostic quality, but with the less possible doses. (Author)

  11. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  12. External radiation monitoring in TAPS and RAPS environs (1980-81) using TLD

    International Nuclear Information System (INIS)

    Basu, A.S.; Nambi, K.S.V.; Sunta, C.M.

    1983-01-01

    Results of environmental external radiation monitoring using quarterly integrated TLD measurements are presented for environments of the Tarapur Atomic Power Station (TAPS) and the Rajasthan Atomic Power Station (RAPS) for the two year monitoring period (1980-81). The data fit into the unimodal log-normal distribution except for locations where gaseous radioactivity escaping from the plant makes a significant contribution. The average natural radiation background in TAPS and RAPS environment is estimated to be 59.6 +- 4.7 mR yr -1 and 65.1 +- 9.8 mR yr -1 respectively. Contribution from the plant superimposed over the natural level leads frequently to bi-normal distribution. The effect of stack-released gaseous radioactivity is seen in locations within 1.6 km of TAPS: for example Ghivoli village registered an excess of 9.3 mR yr -1 over the natural background. The quarterly background values indicate minor temporal and spatial variations which can be attributed to changes in natural as well as stack released radioactivity. (author)

  13. Thermoluminescent dosemeters (TLD) exposed to high fluxes of gamma radiation, thermal neutrons and protons

    International Nuclear Information System (INIS)

    Gambarini, G.; Martini, M.; Meinardi, F.; Raffaglio, C.; Salvadori, P.; Scacco, A.; Sichirollo, A.E.

    1996-01-01

    Thermoluminescent dosemeters (TLD), widely experimented and utilized in personal dosimetry, have some advantageous characteristics which induce one to employ them also in radiotherapy. The new radiotherapy techniques are aimed at selectively depositing a high dose in cancerous tissues. This goal is reached by utilising both conventional and other more recently proposed radiation, such as thermal neutrons and heavy charged particles. In these inhomogeneous radiation fields a reliable mapping of the spatial distribution of absorbed dose is desirable, and the utilized dosemeters have to give such a possibility without notably perturbing the radiation field with the materials of the dosemeters themselves. TLDs, for their small dimension and their tissue equivalence for most radiation, give good support in the mapping of radiation fields. After exposure to the high fluxes of therapeutic beams, some commercial TL dosemeters have shown a loss of reliability. An investigation has therefore be performed, both on commercial and on laboratory made phosphors, in order to investigate their behaviour in such radiation fields. In particular the thermal neutron and gamma ray mixed field of the thermal column of a nuclear reactor, of interest for Boron Neutron Capture Therapy (B.N.C.T.) and a proton beam, of interest for proton therapy, were considered. Here some results obtained with new TL phosphors exposed in such radiation fields are presented, after a short description of some radiation damage effect on commercial LiF TLDs exposed in the (n th ,γ) field of the thermal column of a reactor. (author)

  14. Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level

    International Nuclear Information System (INIS)

    Rosa, Luiz Antonio R. da; Regulla, Dieter F.; Fill, Ute A.

    1999-01-01

    The precision of the thermoluminescent response of Harshaw micro-cube dosimeters (TLD-100), evaluated in both Harshaw thermoluminescent readers 5500 and 3500, for 1 Gy dose value, was investigated. The mean reproducibility for micro-cubes, pre-readout annealed at 100 deg. C for 15 min, evaluated with the manual planchet reader 3500, is 0.61% (1 standard deviation). When micro-cubes are evaluated with the automated hot-gas reader 5500, reproducibility values are undoubtedly worse, mean reproducibility for numerically stabilised dosimeters being equal to 3.27% (1 standard deviation). These results indicate that the reader model 5500, or, at least, the instrument used for the present measurements, is not adequate for micro-cube evaluation, if precise and accurate dosimetry is required. The difference in precision is apparently due to geometry inconsistencies in the orientation of the imperfect micro-cube faces during readout, requiring careful and manual reproducible arrangement of the selected micro-cube faces in contact with the manual reader planchet

  15. Reddish-orange, neutral and warm white emissions in Eu3+, Dy3+ and Dy3+/Eu3+ doped CdO-GeO2-TeO2 glasses

    Science.gov (United States)

    Rodríguez-Carvajal, David A.; Meza-Rocha, A. N.; Caldiño, U.; Lozada-Morales, R.; Álvarez, E.; Zayas, Ma. E.

    2016-11-01

    Eu3+, Dy3+ and Dy3+/Eu3+ doped CdO-GeO2-TeO2 glasses were prepared using the melt-quenching process and analyzed by X-diffraction, Raman spectroscopy, excitation and emission spectra, and emission decay time profiles. The lack of X ray diffraction peaks revealed that all samples are amorphous. Vibrational modes associated with Tesbnd Osbnd Te and Gesbnd Osbnd Ge related bonds and molecular oxygen were detected by Raman spectroscopy. The luminescence characteristics were studied upon excitations that correspond with the emission of InGaN (370-420 nm) based LEDs. The Eu3+ singly doped glass displayed reddish-orange global emission, with x = 0.601 and y = 0.349 CIE1931 chromaticity coordinates, upon 393 nm excitation. Neutral emission with x = 0.373 and y = 0.412 CIE1931 chromaticity coordinates and correlated color temperature (CCT) of 4400 K, was achieved in the Dy3+ singly doped glass excited at 388 nm. The Dy3+/Eu3+ co-doped glass exhibited warm, neutral and soft warm white emissions with CCT values of 3435, 4153 and 2740 K, under excitations at 382, 388 and 393 nm, respectively, depending mainly on the Dy3+ and Eu3+ relative excitation. The Dy3+ excitation bands observed in the Dy3+/Eu3+ glass by monitoring the 611 nm Eu3+ emission, suggest that Dy3+ → Eu3+ energy transfer takes place, despite the fact that the Dy3+ emission decays in the Dy3+ and Dy3+/Eu3+ doped glass, remain without changes. The shortening of Eu3+ decay in presence of Dy3+ was attributed to an Eu3+ → Dy3+ non-radiative energy transfer process, which according with the Inokuti-Hirayama model might be dominated through an electric quadrupole-quadrupole interaction, with efficiency and probability of 5.5% and 51.6 s-1, respectively.

  16. Dyeing of white and indigo dyed cotton fabrics with Mimosa tenuiflora extract

    Directory of Open Access Journals (Sweden)

    Gökhan Erkan

    2014-04-01

    Full Text Available Mimosa tenuiflora extract has been used in food industry as an additive and in textile and leather industry as a colorant. Two types of fabrics, ready to be dyed white and indigo dyed fabrics, were dyed with M. tenuiflora extract. The fabrics were mordanted after dyeing with six different metal salts. Colorimetric evaluations of fabrics were carried out by spectrophotometer. Colour fastness to washing, rubbing and light were performed. Colour strength of fabrics was calculated from Kubelka–Munk formula. Highest vividness (C∗ values were obtained by Ni mordant. Moderate fastness values were observed. However poor wet rubbing fastness values were observed in the case of indigo dyed fabrics due to lack of good wet rubbing fastness of indigo itself.

  17. Fracture toughness of Dy123 low porosity bulks at liquid nitrogen temperature

    International Nuclear Information System (INIS)

    Murakami, A.; Otaka, K.; Miura, T.; Iwamoto, A.

    2011-01-01

    Fracture toughness values were measured for Dy123 bulks. Fracture toughness was improved by reducing porosity. Fracture toughness values at 77 K were higher than those at room temperature. Fracture toughness was also improved by Ag addition. In order to evaluate the fracture toughness of DyBa 2 Cu 3 O x (Dy123) low porosity bulks, bending tests of V-notched specimens cut from the bulks were carried out. Fracture toughness evaluations of a conventional Dy123 bulk which had pores were also carried out and effects of elimination of pores on the fracture toughness were investigated. Fracture toughness values at 77 K of the low porosity bulks were higher than those of the porous bulk. These fracture toughness values at 77 K were higher than the values at room temperature. Fracture toughness of the low porosity bulk was improved by Ag addition.

  18. Tailoring of magnetic properties of ultrathin epitaxial Fe films by Dy doping

    Directory of Open Access Journals (Sweden)

    A. A. Baker

    2015-07-01

    Full Text Available We report on the controlled modification of relaxation parameters and magnetic moments of epitaxial Fe thin films through Dy doping. Ferromagnetic resonance measurements show that an increase of Dy doping from 0.1% to 5% gives a tripling in Gilbert damping, and more importantly a strongly enhanced anisotropic damping that can be qualitatively understood through the slow-relaxing impurity model. X-ray magnetic circular dichroism measurements show a pronounced suppression of the orbital moment of the Fe with Dy doping, leading to an almost threefold drop in the orbital to spin moment ratio, ml/ms. Doping with Dy can therefore be used to control both dynamic and static properties of thin ferromagnetic films for improved performance in spintronics device applications, mediated through the antiferromagnetic interaction of the 4f and 3d states.

  19. Tailoring of magnetic properties of ultrathin epitaxial Fe films by Dy doping

    Energy Technology Data Exchange (ETDEWEB)

    Baker, A. A. [Department of Physics, Clarendon Laboratory, University of Oxford, Oxford, OX1 3PU (United Kingdom); Magnetic Spectroscopy Group, Diamond Light Source, Didcot, OX11 0DE (United Kingdom); Figueroa, A. I.; Laan, G. van der [Magnetic Spectroscopy Group, Diamond Light Source, Didcot, OX11 0DE (United Kingdom); Hesjedal, T. [Department of Physics, Clarendon Laboratory, University of Oxford, Oxford, OX1 3PU (United Kingdom)

    2015-07-15

    We report on the controlled modification of relaxation parameters and magnetic moments of epitaxial Fe thin films through Dy doping. Ferromagnetic resonance measurements show that an increase of Dy doping from 0.1% to 5% gives a tripling in Gilbert damping, and more importantly a strongly enhanced anisotropic damping that can be qualitatively understood through the slow-relaxing impurity model. X-ray magnetic circular dichroism measurements show a pronounced suppression of the orbital moment of the Fe with Dy doping, leading to an almost threefold drop in the orbital to spin moment ratio, m{sub l}/m{sub s}. Doping with Dy can therefore be used to control both dynamic and static properties of thin ferromagnetic films for improved performance in spintronics device applications, mediated through the antiferromagnetic interaction of the 4f and 3d states.

  20. Synthesis, characterization and photoluminescence properties of Dy3+ -doped nano-crystalline SnO2.

    CSIR Research Space (South Africa)

    Pillai, SK

    2010-04-15

    Full Text Available the crystallite size. The experimental result on photoluminescence characteristics originating from Dy3+-doping in nanocrystalline SnO2 reveals the dependence of the luminescent intensity on dopant concentration....

  1. Judd-Ofelt Analysis of Dy3+-Activated Aluminosilicate Glasses Prepared by Sol-Gel Method

    Science.gov (United States)

    Sengthong, Buonyavong; Van Tuyen, Ho; An, Nguyen Thi Thai; Van Do, Phan; Hai, Nguyen Thi Quy; Chau, Pham Thi Minh; Quang, Vu Xuan

    2018-04-01

    Aluminosilicate (AS) glasses doped with different Dy3+ concentrations were synthesized via sol-gel method. Absorption, photoluminescence spectra and lifetime of this material have been studied. From analytical results of absorption spectra, the Judd-Ofelt (JO) parameters of prepared samples have been determined. These JO parameters combined with photoluminescence spectra have been used to evaluate transition probabilities ( A R), branching ratios ( β) and the calculated oscillator strengths of AS:Dy3+ glasses. The radiative branching ratio of 4F9/2 → 6H13/2 transition has a minimum value at 62.2% for β R which predicts that this transition in AS:Dy3+ glasses can give rise to lasing action. JO parameters show that the Ω2 increases with the increasing of Dy3+ ion concentration due to the increased polarizability of the average coordination medium and decreased average symmetry.

  2. Laccase treatment of recycled blue dyed paper: Physical properties and fiber charge

    Digital Repository Service at National Institute of Oceanography (India)

    Mohandass, C.; Knutson, K.; Ragauskas, A.J.

    Recycled blue colored paper was treated with laccase under various combinations of physical and chemical parameters including enzyme concentration, temperature, oxygen, and reaction time. Laccase treatment of recycled dyed pulp increased acid group...

  3. Electronic structure and magnetic properties of Dy adatom on Ir surface

    Science.gov (United States)

    Shick, A. B.; Lichtenstein, A. I.

    2018-05-01

    The electronic structure and magnetism of individual Dy atom adsorbed on the (1 1 1) surface of Ir is investigated using the combination of the density functional theory with the Hubbard-I approximation to the Anderson impurity model (DFT + HIA). The Dy3+ adatom is found magnetic with the magnetic moment of 9.35μB in the external magnetic field. The spin and orbital magnetic moments, and their ratio are evaluated, and compared with the X-ray magnetic circular dichroism data. The positive magnetic anisotropy energy of ≈ 1.3 meV determines the out-of-plane orientation of the Dy adatom magnetic moment. The role of 5d-4f interorbital exchange polarization in modification of the 4f shell energy spectrum is emphasized. We predict the Dy magnetization to drop by the factor of three with switching off the external magnetic field.

  4. Detection of unusual spin reorientation induced by magnetic field in DyFeO3

    International Nuclear Information System (INIS)

    Balbashov, A.M.; Marchukov, P.Yu.; Nikolaev, I.V.; Rudashevskij, E.G.

    1988-01-01

    It is detected that in DyFeO 3 the vector of antiferromagnetism reorientates continuously in two mutually perpendicular planes, and transition from one plane into the other one is a first-order phase transformation

  5. Selective arc-discharge synthesis of Dy2S-clusterfullerenes and their isomer-dependent single molecule magnetism.

    Science.gov (United States)

    Chen, Chia-Hsiang; Krylov, Denis S; Avdoshenko, Stanislav M; Liu, Fupin; Spree, Lukas; Yadav, Ravi; Alvertis, Antonis; Hozoi, Liviu; Nenkov, Konstantin; Kostanyan, Aram; Greber, Thomas; Wolter, Anja U B; Popov, Alexey A

    2017-09-01

    A method for the selective synthesis of sulfide clusterfullerenes Dy 2 S@C 2 n is developed. Addition of methane to the reactive atmosphere reduces the formation of empty fullerenes in the arc-discharge synthesis, whereas the use of Dy 2 S 3 as a source of metal and sulfur affords sulfide clusterfullerenes as the main fullerene products along with smaller amounts of carbide clusterfullerenes. Two isomers of Dy 2 S@C 82 with C s (6) and C 3v (8) cage symmetry, Dy 2 S@C 72 - C s (10528), and a carbide clusterfullerene Dy 2 C 2 @C 82 - C s (6) were isolated. The molecular structure of both Dy 2 S@C 82 isomers was elucidated by single-crystal X-ray diffraction. SQUID magnetometry demonstrates that all of these clusterfullerenes exhibit hysteresis of magnetization, with Dy 2 S@C 82 - C 3v (8) being the strongest single molecule magnet in the series. DC- and AC-susceptibility measurements were used to determine magnetization relaxation times in the temperature range from 1.6 K to 70 K. Unprecedented magnetization relaxation dynamics with three consequent Orbach processes and energy barriers of 10.5, 48, and 1232 K are determined for Dy 2 S@C 82 - C 3v (8). Dy 2 S@C 82 - C s (6) exhibits faster relaxation of magnetization with two barriers of 15.2 and 523 K. Ab initio calculations were used to interpret experimental data and compare the Dy-sulfide clusterfullerenes to other Dy-clusterfullerenes. The smallest and largest barriers are ascribed to the exchange/dipolar barrier and relaxation via crystal-field states, respectively, whereas an intermediate energy barrier of 48 K in Dy 2 S@C 82 - C 3v (8) is assigned to the local phonon mode, corresponding to the librational motion of the Dy 2 S cluster inside the carbon cage.

  6. Genotoxic and cytotoxic damage by the therapeutic radiopharmaceutical [166Dy]Dy/166Ho-EDTMP as in vivo generator system

    International Nuclear Information System (INIS)

    Pedraza L, M.; Piedras R, J.; Ferro F, G.; Morales R, P.; Murphy S, E.; Hernandez O, O.

    2005-01-01

    In patients with leukemias and multiple myeloma, the cure can be obtained to inclination of a bone marrow transplant (m.o.), for that which one is used a combination of external radiotherapy and chemotherapy with the consequent toxicity to healthy organs. The complex [ 166 Dy]Dy/ 166 Ho-ethylenediaminetetramethylenephosphonate ([ 166 Dy]Dy/ 166 Ho-EDTMP) it forms a generator system in vivo stable with bony selective likeness in mice therefore, this it could work as a therapeutic radiopharmaceutical for bone marrow ablation. The objective of this original work was to determine the genotoxic and cytotoxic damage produced by the [ 166 Dy]Dy/ 166 Ho-EDTMP like a generator system in vivo by means of the reticulocytes reduction (RET) and micronucleus elevation in reticulocytes (RET-MN) in peripheral blood and to evaluate its myeloablative potential for histopathologic studies. It was irradiated 166 Dy 2 O 3 enriched and it was add in form 166 DyCI 3 to the EDTMP in a softening media of phosphates (pH 8), the optimal molar relationship 166 Dy: EDTMP was 1.7:1 and the radiochemical purity was evaluated by ITLC. The Dy:EDTMP complexes, non radioactive, its were prepared in the same way with non irradiated dysprosium oxide. A group of BALB/c mice was injected intraperitoneally with the radiopharmaceutical and two groups of control mice were injected with the non radioactive complex and with sodium chloride 0.9% respectively. Before injecting each one of the solutions it was take a basal sample of peripheral blood of the mouse tail and each 48 h post-injection during 12 d. The animals were sacrificed to obtain the organs of interest and to determine the radioactivity in each one. The femur was used for the histopathologic studies. The quantification of the frequency of RET and RET-MN was carried out by flow cytometry of the sanguine samples and the Monte Carlo code MCNP4B for the dosimetry calculations was used. The radiochemical purity was 99% and in average the specific

  7. [Validity and reliability of the spanish EQ-5D-Y proxy version].

    Science.gov (United States)

    Gusi, N; Perez-Sousa, M A; Gozalo-Delgado, M; Olivares, P R

    2014-10-01

    A proxy version of the EQ-5D-Y, a questionnaire to evaluate the Health Related Quality of Life (HRQoL) in children and adolescents, has recently been developed. There are currently no data on the validity and reliability of this tool. The objective of this study was to analyze the validity and reliability of the EQ-5D-Y proxy version. A core set of self-report tools, including the Spanish version of the EQ-5D-Y were administered to a group of Spanish children and adolescents drawn from the general population. A similar core set of internationally standardized proxy tools, including the EQ-5D-Y proxy version were administered to their parents. Test-retest reliability was determined, and correlations with other generic measurements of HRQoL were calculated. Additionally, known group validity was examined by comparing groups with a priori expected differences in HRQoL. The agreement between the self-report and proxy version responses was also calculated. A total of 477 children and adolescents and their parents participated in the study. One week later, 158 participants completed the EQ-5D-Y/EQ-5D-Y proxy to facilitate reliability analysis. Agreement between the test-retest scores was higher than 88% for EQ-5D-Y self-report, and proxy version. Correlations with other health measurements showed similar convergent validity to that observed in the international EQ-5D-Y. Agreement between the self-report and proxy versions ranged from 72.9% to 97.1%. The results provide preliminary evidence of the reliability and validity of the EQ-5D-Y proxy version. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  8. Dy:Eu doped CaBAl glasses for white light applications

    Science.gov (United States)

    Lodi, T. A.; Sandrini, M.; Medina, A. N.; Barboza, M. J.; Pedrochi, F.; Steimacher, A.

    2018-02-01

    The combination of Eu3+ and Dy3+ in co-doped glassy materials provides interesting applicability for white light emission devices. In this work, Dy:Eu doped Calcium Boroaluminate (CaBAl) glasses were prepared by conventional melting quenching, with 3 wt% of Dy2O3 and Eu2O3 content varying from 0 to 3 wt%, and results of absorption spectra, photoluminescence and photoluminescence lifetime are discussed in terms of Eu2O3 content. The photoluminescence of the samples was studied under excitation of 365 and 405 nm light source. The 365 nm excitation shows favor to the Dy3+ ion emission. The results of photoluminescence lifetime at 575 nm (Dy3+) shows a decrease due to Eu2O3 addition, which suggests an energy transfer from Dy3+ (donor) to the Eu3+ (acceptor). On the other hand, under excitation of 405 nm, the photoluminescence lifetime at 575 nm (Dy3+) shows no significant changes due to Eu2O3 amount, which indicates that the energy transfer from Dy3+ to Eu3+ (under λexc = 405 nm) is negligible. However, the results of photoluminescence under 405 nm excitation present a white yellowish emission in the CIE diagram, which shifts to red with Eu2O3 addition. The combination of a Blue LED (BL) emission with the emission of the samples was also studied in the CIE diagram, in order to improve light emission and to obtain ideal White Light (WL). The results show that by modifying the emission intensity of BL, it is possible to achieve a route for smart lighting, close to the circadian light cycle.

  9. A critical scattering study of the helical antiferromagnets Ho and Dy

    International Nuclear Information System (INIS)

    Gaulin, B.D.; Hagen, M.; Child, H.R.

    1988-01-01

    We have measured the frequency integrated magnetic critical scattering of neutrons from paramagnetic Dy and Ho. Analysis of these data show the paramagnetic to helical antiferromagnetic phase transitions are characterized by the critical exponents ν = 0.57 +- 0.05 and γ = 1.05 = +- .07 for Dy and ν = 0.57 +- .04 and γ = 1.14 = +- .10 for Ho. 3 refs., 2 figs., 1 tab

  10. Fading of LiF and CaF2:Dy

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Weiser, G.

    1983-03-01

    The fading of LiF and CaF 2 :Dy was investigated and the results were compared to the literature. The effect of thermal annealing was studied in order to reduce the fading in both phosphors and to minimize the effects of the environment on CaF 2 :Dy. Minimizing the fading and knowing its time dependence make possible the exact personal and environmental dosimetry. (Author)

  11. From a Dy(III) single molecule magnet (SMM) to a ferromagnetic [Mn(II)Dy(III)Mn(II)] trinuclear complex.

    Science.gov (United States)

    Bhunia, Asamanjoy; Gamer, Michael T; Ungur, Liviu; Chibotaru, Liviu F; Powell, Annie K; Lan, Yanhua; Roesky, Peter W; Menges, Fabian; Riehn, Christoph; Niedner-Schatteburg, Gereon

    2012-09-17

    The Schiff base compound 2,2'-{[(2-aminoethyl)imino]bis[2,1-ethanediyl-nitriloethylidyne]}bis-2-hydroxy-benzoic acid (H(4)L) as a proligand was prepared in situ. This proligand has three potential coordination pockets which make it possible to accommodate from one to three metal ions allowing for the possible formation of mono-, di-, and trinuclear complexes. Reaction of in situ prepared H(4)L with Dy(NO(3))(3)·5H(2)O resulted in the formation of a mononuclear complex [Dy(H(3)L)(2)](NO(3))·(EtOH)·8(H(2)O) (1), which shows SMM behavior. In contrast, reaction of in situ prepared H(4)L with Mn(ClO(4))(2)·6H(2)O and Dy(NO(3))(3)·5H(2)O in the presence of a base resulted in a trinuclear mixed 3d-4f complex (NHEt(3))(2)[Dy{Mn(L)}(2)](ClO(4))·2(H(2)O) (2). At low temperatures, compound 2 is a weak ferromagnet. Thus, the SMM behavior of compound 1 can be switched off by incorporating two Mn(II) ions in close proximity either side of the Dy(III). This quenching behavior is ascribed to the presence of the weak ferromagnetic interactions between the Mn(II) and Dy(III) ions, which at T > 2 K act as a fluctuating field causing the reversal of magnetization on the dysprosium ion. Mass spectrometric ion signals related to compounds 1 and 2 were both detected in positive and negative ion modes via electrospray ionization mass spectrometry. Hydrogen/deuterium exchange (HDX) reactions with ND(3) were performed in a FT-ICR Penning-trap mass spectrometer.

  12. Dy{sup 3+} ions as optical probes for studying structure of boro-tellurite glasses

    Energy Technology Data Exchange (ETDEWEB)

    Tuyen, Vu Phi, E-mail: vptuyen@gust-edu.vast.vn [Duytan University, K7/25 Quang Trung, Da Nang (Viet Nam); Graduate University of Science and Technology – VAST, 18 Hoang Quoc Viet, Hanoi (Viet Nam); Sengthong, Bounyavong; Quang, Vu Xuan [Duytan University, K7/25 Quang Trung, Da Nang (Viet Nam); Van Do, Phan [Thuyloi University, 175 Tay Son, Dong Da, Hanoi (Viet Nam); Van Tuyen, Ho; Xuan Hung, Le [Duytan University, K7/25 Quang Trung, Da Nang (Viet Nam); Thanh, Nguyen Trong [Institute of Materials Science – VAST, 18 Hoang Quoc Viet, Hanoi (Viet Nam); Nogami, Masayuki [Duytan University, K7/25 Quang Trung, Da Nang (Viet Nam); Toyota Physical and Chemical research Institute (Japan); Hayakawa, Tomokatsu [Nagoya Institute of Technology, Gokisocho Showaku, 466-8555 Nagoya, Aichiken (Japan); Huy, Bui The, E-mail: buithehuy.nt@gmail.com [Duytan University, K7/25 Quang Trung, Da Nang (Viet Nam); Department of Chemistry, Changwon National University, Changwon 641-773 (Korea, Republic of)

    2016-10-15

    Dy{sup 3+}-doped glasses with various compositions (35+x)B{sub 2}O{sub 3}+ (45−x)TeO{sub 2}+9.5ZnO+10Na{sub 2}O+0.5Dy{sub 2}O{sub 3} (x=0; 10 and 20) were prepared by a melt–quenching technique. The Dy{sup 3+} ions are used as an optical probe, of which the Judd–Ofelt parameters, the phonon-side band, and the Raman spectra were quantitatively estimated to search the change of glass structure (the change of the ratio of [BO{sub 4}] to [BO{sub 3}] units, formation of the non-bridging oxygens (NBO{sup −}), the change of [TeO{sub 3}] to [TeO{sub 4}] units) as a function of the B{sub 2}O{sub 3} content. The Ω{sub 2} and Ω{sub 6} values of Dy{sup 3+}-doped boro-tellurite samples are larger than that of Dy{sup 3+}-doped borate or tellurite sample. The CIE chromaticity color coordinates were calculated for the luminescence spectra of Dy{sup 3+} ions of the glasses with the different compositions and they were all located in the vicinity of white light center of the color coordination diagram.

  13. Efficient photoluminescence of Dy3+ at low concentrations in nanocrystalline ZrO2

    International Nuclear Information System (INIS)

    Diaz-Torres, L.A.; Rosa, E. de la; Salas, P.; Romero, V.H.; Angeles-Chavez, C.

    2008-01-01

    Nanocrystalline ZrO 2 :Dy 3+ were prepared by sol-gel and the structural and photoluminescence properties characterized. The crystallite size ranges from 20 to 50 nm and the crystalline phase is a mixture of tetragonal and monoclinic structure controlled by dopant concentration. Strong white light produced by the host emission band centered at ∼460 nm and two strong Dy 3+ emission bands, blue (488 nm) and yellow (580 nm), under direct excitation at 350 nm were observed. The highest efficiency was obtained for 0.5 mol% of Dy 3+ . Emission is explained in terms of high asymmetry of the host suggesting that Dy 3+ are substituted mainly into Zr 4+ lattice sites at the crystallite surface. Luminescence quenching is explained in terms of cross-relaxation of intermediate Dy 3+ levels. - Graphical abstract: White light emission from ∼70 nm ZrO 2 :Dy 3+ nanocrystals. The highest efficiency was obtained for 0.5 mol% of dopant and the dominant crystalline structure was monoclinic

  14. Sonochemical synthesis of Dy-doped ZnO nanostructures and their photocatalytic properties

    Energy Technology Data Exchange (ETDEWEB)

    Yayapao, Oranuch [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thongtem, Titipun, E-mail: ttpthongtem@yahoo.com [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Phuruangrat, Anukorn, E-mail: phuruangrat@hotmail.com [Department of Materials Science and Technology, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112 (Thailand); Thongtem, Somchai [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2013-11-05

    Highlights: •Undoped and Dy-doped ZnO used as photocatalysts. •They were synthesized by sonochemistry. •The promising materials for treatment of organic pollutants. -- Abstract: Dy-doped ZnO nanostructures were synthesized by a sonochemical method. The concentration effect of Dy on their phase, morphology, optical properties and photocatalytic activities was investigated. XRD patterns indicated that the as-synthesized 0–3% Dy-doped ZnO was hexagonal wurtzite structure. SEM and TEM show that the products were nanorods with their growth direction along the c axis. The photoluminescence spectrum of 3% Dy-doped ZnO, applied by Gaussian analysis, consists of three emission peaks at 376 nm, 448 nm and 487 nm. The photocatalytic activities of the as-synthesized products were determined from the degradation of methylene blue (C{sub 16}H{sub 18}N{sub 3}SCl) by UV radiation. In this research, the 3% Dy-doped ZnO showed the highest photocatalytic activity.

  15. Sonochemical synthesis of Dy-doped ZnO nanostructures and their photocatalytic properties

    International Nuclear Information System (INIS)

    Yayapao, Oranuch; Thongtem, Titipun; Phuruangrat, Anukorn; Thongtem, Somchai

    2013-01-01

    Highlights: •Undoped and Dy-doped ZnO used as photocatalysts. •They were synthesized by sonochemistry. •The promising materials for treatment of organic pollutants. -- Abstract: Dy-doped ZnO nanostructures were synthesized by a sonochemical method. The concentration effect of Dy on their phase, morphology, optical properties and photocatalytic activities was investigated. XRD patterns indicated that the as-synthesized 0–3% Dy-doped ZnO was hexagonal wurtzite structure. SEM and TEM show that the products were nanorods with their growth direction along the c axis. The photoluminescence spectrum of 3% Dy-doped ZnO, applied by Gaussian analysis, consists of three emission peaks at 376 nm, 448 nm and 487 nm. The photocatalytic activities of the as-synthesized products were determined from the degradation of methylene blue (C 16 H 18 N 3 SCl) by UV radiation. In this research, the 3% Dy-doped ZnO showed the highest photocatalytic activity

  16. Effect of Dy addition on mechanical and magnetic properties of Mn-rich Ni–Mn–Ga ferromagnetic shape memory alloys

    International Nuclear Information System (INIS)

    Gao, L.; Dong, G.F.; Gao, Z.Y.; Cai, W.

    2012-01-01

    Highlights: ► The Dy addition significantly improves the compressive properties of Ni–Mn–Ga alloy. ► The mechanism of the improved mechanical properties by adding Dy is discussed. ► Dy doping results in a change of the fracture type of Ni–Mn–Ga alloy. ► Curie temperature almost remained unchanged at low Dy content and then decreases. - Abstract: The effects of partial substitution of rare earth Dy for Ga on the mechanical and magnetic properties of Mn-rich Ni 50 Mn 29 Ga 21−x Dy x (0 ≤ x ≤ 5) ferromagnetic shape memory alloys were investigated in detail. The results show that an appropriate amount of Dy addition significantly improves the mechanical properties of Ni–Mn–Ga alloy. With an increase in Dy content, the compressive strength enhances rapidly at first and then becomes stable when the Dy content is more than 1 at.%. However, the compressive strain increases dramatically and reaches a maximum value with 1 at.% Dy addition. Further increase in Dy content makes the compressive strain of the alloys decrease gradually. The mechanism of the improved mechanical properties is also discussed. Moreover, Dy doping changes the fracture type from intergranular fracture of Ni–Mn–Ga alloy to transgranular cleavage fracture of Ni–Mn–Ga–Dy alloys. The Curie temperature remains almost unchanged at low Dy content and subsequently decreases.

  17. Feasibility study of electrophoresis deposition of DyF3 on Nd-Fe-B particles for coercivity enhancement

    Directory of Open Access Journals (Sweden)

    K. M. Kim

    2018-05-01

    Full Text Available Feasibility of the electrophoresis deposition (EPD technique for homogeneous and adhesive deposition of DyF3 particles on the Nd-Fe-B-type particles was studied, and coercivity enhancement in the diffusion-treated Nd-Fe-B-type particles deposited with DyF3 by EPD was investigated. HDDR-treated Nd12.5Fe80.6B6.4Ga0.3Nb0.2 particles were deposited with DyF3 particles by EPD. More homogeneous and adhesive deposition of DyF3 particles on the surface of Nd-Fe-B particles was made by the EPD with respect to conventional dip-coating, and this led to more active and homogeneous diffusion of Dy. More profound coercivity enhancement was achieved in the diffusion-treated Nd-Fe-B-type particles deposited with DyF3 by EPD compared to dip-coated particles.

  18. Modulating the single-molecule magnet behaviour in phenoxo-O bridged Dy2 systems via subtle structural variations

    Science.gov (United States)

    Wang, Wen-Min; Zhao, Xiao-Yu; Qiao, Hui; Bai, Li; Han, Hong-Fei; Fang, Ming; Wu, Zhi-Lei; Zou, Ji-Yong

    2017-09-01

    In search of simple approaches to rationally modulate the single-molecule magnet behaviour in polynuclear lanthanide compound, a new system containing two structurally closely related dinuclear dysprosium complexes, namely [Dy2(hfac)4L2] (1) and [Dy2(hfac)4L‧2] (2) (hfac = hexafluoroacetylacetonate, HL = 2-[4-methylaniline-imino]methyl]-8-hydroxyquinoline and HL' = 2-[(3,4-dimethylaniline)-imino]methyl]-8-hydroxyquinoline), are successfully synthesized and the structure-dependent magnetic properties are investigated. The two Dy2 compounds display only slight variations in the coordination geometries of the center Dy(III) ion but display remarkably different single-molecule magnet behaviors with the anisotropic barriers (ΔE/kB) of 9.91 K for 1 and 20.57 K for 2. The different magnetic relaxation behaviors of the two Dy2 complexes mainly originate from the different chemical environments of the central DyIII ions.

  19. Feasibility study of electrophoresis deposition of DyF3 on Nd-Fe-B particles for coercivity enhancement

    Science.gov (United States)

    Kim, K. M.; Kang, M. S.; Kwon, H. W.; Lee, J. G.; Yu, J. H.

    2018-05-01

    Feasibility of the electrophoresis deposition (EPD) technique for homogeneous and adhesive deposition of DyF3 particles on the Nd-Fe-B-type particles was studied, and coercivity enhancement in the diffusion-treated Nd-Fe-B-type particles deposited with DyF3 by EPD was investigated. HDDR-treated Nd12.5Fe80.6B6.4Ga0.3Nb0.2 particles were deposited with DyF3 particles by EPD. More homogeneous and adhesive deposition of DyF3 particles on the surface of Nd-Fe-B particles was made by the EPD with respect to conventional dip-coating, and this led to more active and homogeneous diffusion of Dy. More profound coercivity enhancement was achieved in the diffusion-treated Nd-Fe-B-type particles deposited with DyF3 by EPD compared to dip-coated particles.

  20. Crystallographic and magnetic properties of (Nd,Dy)3Fe27.5(Ti,Mo)1.5 compounds

    International Nuclear Information System (INIS)

    Han, S.B.; Liu, X.F.; Lv, J.Y.; Peng, J.; Hao, Y.M.; Li, X.J.; Chen, D.F.; Xue, Y.J.; Li, J.H.; Hu, Z.B.

    2006-01-01

    A systematic study of the formation, structure and magnetic properties of (Nd,Dy) 3 Fe 27.5 (Ti,Mo) 1.5 compounds has been performed. Rietveld analyses of the X-ray patterns of the samples indicate that the concentrations of Ti and Mo affect the formation and structural properties slightly, whereas different rare-earth (Nd and Dy) contents influence them significantly. It is found that high Dy contents make it difficult to form the 3:29-type structures. The Curie temperatures of Nd 2.1 Dy 0.9 Fe 27.5 Ti 1.5- x Mo x decrease monotonically as more Ti was replaced by Mo but their saturation magnetizations remain almost unchanged; in contrast, for Nd 3- y Dy y Fe 27.5 TiMo 0.5 , their saturation magnetizations decrease monotonically with increasing Dy contents while their Curie temperatures are constant

  1. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia

    International Nuclear Information System (INIS)

    Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H.

    2014-08-01

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  2. Long-term TLD measurements of environmental background radiation in the New York City Area

    International Nuclear Information System (INIS)

    Maiello, M.

    1994-11-01

    The results of month-long TLD measurements at seven locations within 150 km of New York City are reported for 12 years at a few locations and for up to 18 years at others. At some locations, multiple dosimeters were deployed to acquire concurrent indoor and outdoor measurements. The sites were varied and include an urban high-rise residence, three suburban backyards, a rural hillside, and the wooded outskirts of a nuclear power plant (nonoperational). Long-term mean dose rates in air ranged from 50.8 to 123.1 nGy h -1 (5.8 to 14.1 μR h -1 ) across the area. The typical seasonal dose rate in air variations are presented for two of the sites and are briefly discussed in terms of soil conditions. The data indicate that it is possible to achieve monthly variations from the long-term mean as high as 20 to 40%. One of these locations was monitored for indoor (2 floors) and outdoor air dose rates. This allowed for a time series comparison to be performed illustrating the changing contribution of terrestrial radiation to the total dose rate relative to the steady building material-derived radioactivity. This site also permitted the calculation of indoor/outdoor ratios for two floors. Another suburban location yielded an indoor/outdoor ratio using ground floor dose-rate-in-air measurements. Also presented are mean annual dose rates in air showing a long-term decrease at some locations. A statistical Kendall test was performed to quantify the magnitude of the decrease. A definitive explanation of this trend requires further study

  3. Measurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field

    Directory of Open Access Journals (Sweden)

    Farhood B.

    2016-06-01

    Full Text Available Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields. Objective: In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated. Materials and Methods: Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patient’s setup, the technologists’ experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software. Results: The average age of the patients was 46±10 years. The average of thyroid dose of the patients was 140±45 mGy (ranged 288.2 and 80.8 in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patient’s setup time. Conclusion: Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patient’s setup, etc. could be considered.

  4. Response analysis of TLD-300 dosimeters in heavy-particle beams

    International Nuclear Information System (INIS)

    Loncol, Th.; Hamal, M.; Vynckier, S.; Scalliet, P.; Denis, J.M.; Wambersie, A.

    1996-01-01

    In vivo dosimetry is recommended as part of the quality control procedure for treatment verification in radiation therapy. Using thermoluminescence, such controls are planned in the p(65)+Be neutron and 85 MeV proton beams produced at the cyclotron at Louvain-La-Neuve and dedicated to therapy applications. A preliminary study of the peak 3 (150 deg. C) and peak 5 (250 deg. C) response of CaF 2 :Tm (TLD-300) to neutron and proton beams aimed to analyse the effect of different radiation qualities on the dosimetric behaviour of the detector irradiated in phantom. To broaden the range of investigation, the study was extended to an experimental C-12 heavy ion beam (95 MeV/nucleon). The peak 3 and 5 sensitivities in the neutron beam, compared to Co-60, varied little with depth. A major change of peak 5 sensitivity was observed for samples positioned under five leaves of the multi-leaf collimator. While peak 3 sensitivity was constant with depth in the unmodulated proton beam, peak 5 sensitivity increased by 15%. Near the Bragg peak, peak 3 showed the highest decrease of sensitivity. In the modulated proton beam, the sensitivity values were not significantly smaller than those measured in the unmodulated beam far from the Bragg peak region. The ratio of the heights of peak 3 and peak 5 decreased by 70% from the Co-60 reference radiation to the C-12 heavy-ion beam. This parameter was strongly correlated with the change of radiation quality. (author)

  5. Role of hydrogen in Nd–Fe–B sintered magnets with DyH{sub x} addition

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Pan [State Key Laboratory of Silicon Materials, Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Ma, Tianyu, E-mail: maty@zju.edu.cn [Key Laboratory of Novel Materials for Information Technology of Zhejiang Province, Zhejiang University, Hangzhou 310027 (China); Wang, Xinhua, E-mail: xinhwang@zju.edu.cn [State Key Laboratory of Silicon Materials, Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Zhang, Yujing [State Key Laboratory of Silicon Materials, Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Yan, Mi [State Key Laboratory of Silicon Materials, Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Key Laboratory of Novel Materials for Information Technology of Zhejiang Province, Zhejiang University, Hangzhou 310027 (China)

    2015-04-15

    Highlights: • DyH{sub 2} and DyH{sub 3} fine powder were prepared. • Effect of DyH{sub x} on the magnetic properties of Nd–Fe–B sintered magnets was studied. • The effect mechanism of Dy hydrides was discussed. • The magnetic properties are greatly improved by DyH{sub 2} and DyH{sub 3} addition. - Abstract: In order to improve the coercivity of Nd–Fe–B sintered magnets, DyH{sub 2} and DyH{sub 3} fine powders were prepared and used as additive for preparing Nd–Fe–B sintered magnets. The effects of DyH{sub x} powders addition on the microstructures and the magnetic properties of the magnets have been investigated. It was found that hydrogen will react with oxygen of NdO{sub x} rich intergranular phases to form Nd rich phases by dysprosium hydride addition. The Nd-rich grain boundary phases are more homogenous and continuous because the volume fraction of Nd-rich grain boundary phases increases with respect to the Nd oxide phases. After desorption, fine dysprosium powders become more active and wrap matrix phases well so that the diffusion of dysprosium to the surface layer of matrix phases is convenient, so dysprosium decreases in grain boundary phases and aggregates in surface layer of matrix phases. Then, intrinsic coercivity of NdFeB sintered magnets is improved from 14.96 kOe to 20.5 kOe and 20.31 kOe by 2.0 wt.% DyH{sub 3} and 2.0 wt.% DyH{sub 2} addition, respectively. This study has shown that DyH{sub x} addition can reduce the content of oxygen in grain boundary phases. This can be an effective method for massive production.

  6. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba; Servicio Postal TLD para auditorias de calidad de haces de Co-60 en condiciones de referencia en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, C. Habana (Cuba)]. e-mail: stefan@cphr.edu.cu

    2006-07-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  7. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

    Science.gov (United States)

    Koivisto, J; Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.

  8. Structure and magnetic properties of hot deformed Nd2Fe14B magnets doped with DyHx nanoparticles

    Science.gov (United States)

    Wang, C. G.; Yue, M.; Zhang, D. T.; Liu, W. Q.; Zhang, J. X.

    2016-04-01

    Commercial NdFeB powders mixed with DyHx nanoparticles are hot pressed and hot deformed into anisotropic magnets by Spark Plasma Sintering (SPS). The hot deformed magnet exhibits strong c-axis crystallographic texture. The coercivity of the magnet doped with 1.0 wt% DyHx is increased by 66.7%, compared with the magnet without DyHx, while the remanence decreases only by 3%. TEM observation shows that there exists a continuous (Nd,Dy)2Fe14B layer between Nd-rich phase and NdFeB main phase.

  9. Evaluating secondary neutron doses of a refined shielded design for a medical cyclotron using the TLD approach

    International Nuclear Information System (INIS)

    Lin, Jye-Bin; Tseng, Hsien-Chun; Liu, Wen-Shan; Lin, Ding-Bang; Hsieh, Teng-San; Chen, Chien-Yi

    2013-01-01

    An increasing number of cyclotrons at medical centers in Taiwan have been installed to generate radiopharmaceutical products. An operating cyclotron generates immense amounts of secondary neutrons from reactions such the 18 O(p, n) 18 F, used in the production of FDG. This intense radiation can be hazardous to public health, particularly to medical personnel. To increase the yield of 18 F-FDG from 4200 GBq in 2005 to 48,600 GBq in 2011, Chung Shan Medical University Hospital (CSMUH) has prolonged irradiation time without changing the target or target current to meet requirements regarding the production 18 F. The CSMUH has redesigned the CTI Radioisotope Delivery System shield. The lack of data for a possible secondary neutron doses has increased due to newly designed cyclotron rooms. This work aims to evaluate secondary neutron doses at a CTI cyclotron center using a thermoluminescent dosimeter (TLD-600). Two-dimensional neutron doses were mapped and indicated that neutron doses were high as neutrons leaked through self-shielded blocks and through the L-shaped concrete shield in vault rooms. These neutron doses varied markedly among locations close to the H 2 18 O target. The Monte Carlo simulation and minimum detectable dose are also discussed and demonstrated the reliability of using the TLD-600 approach. Findings can be adopted by medical centers to identify radioactive hot spots and develop radiation protection. - Highlights: • Neutron doses were verified using TLD approach. • Neutron doses were increased at cyclotron centers. • Revised L-shaped shield suppresses effectively the neutrons. • Neutron dose can be attenuated to 1.13×10 6 %

  10. Facile synthesis, structural characterization, and photoluminescence mechanism of Dy3+ doped YVO4 and Ca2+ co-doped YVO4:Dy3+ nano-lattices

    Science.gov (United States)

    Dhiren Meetei, Sanoujam; Deben Singh, Mutum; Dorendrajit Singh, Shougaijam

    2014-05-01

    Light plays a vital role in the evolution of life. From sunlight to candle-light and then to other form of lighting devices, human beings are utilizing light since time immemorial. Lighting devices such as conventional incandescent lamp and fluorescent lamp have been replaced by Light Emitting Diodes (LEDs) for the later is cheap, durable, etc. Now-a-days, phosphor converted LEDs have been burning issues in the fabrication of lighting devices. Especially, lanthanide ion(s) doped phosphors are of great interest for the same. However, doped phosphors have a limitation of luminescence quenching, i.e., instead of increasing luminescence on increasing dopant concentration, the luminescence decreases. Therefore, it must be rectified by one or other means so as to get maximum desirable intensity for uses in display or lighting devices. In the present work, YVO4:Dy3+ and YVO4:Dy3+/Ca2+ nano-lattices are synthesized by a facile technique. Structural characterizations such as x-ray diffraction, SEM, TEM, HRTEM, and Selected Area Electron Diffraction (SAED) of the samples are reported. Photoluminescence (PL) excitation and emission, enhanced mechanism, and lifetime are thoroughly discussed. PL intensity of the quenched YVO4:Dy3+ is made increased up to 432.63% by Ca2+ co-doping. Role of the Ca2+ on the luminescence enhanced mechanism of YVO4:Dy3+/Ca2+ is elucidated.

  11. Analysis on the evaluation of dose of the team reader TLD SOLARO, post-adjustment of the heating resistance marks

    International Nuclear Information System (INIS)

    Morales C, M.

    2000-09-01

    This report describes the process carried out in the area of personal dosimetry as for different evaluations carried out in the team reader TLD SOLARO it marks, which evaluates chips of LiF and cards containing two pellets of LiF-700, to determine if after having carried out an adjustment in the heating system the dose evaluations they continue being acceptable, that is to say, the evaluated doses stay inside the error margin allowed for the case of external individual monitoring

  12. The intercomparison of 137Cs irradiator output measurement and personal dose equivalent, Hp(10), using TLD and film

    International Nuclear Information System (INIS)

    Nazaroh; Susetyo Trijoko; Sri Inang Sunaryati

    2010-01-01

    Intercomparison of output measurement of 137 Cs irradiator and personal dose equivalent, Hp(10) using TLD and film have been carried out in the year of 2006 to 2008. According to IAEA recommendation, intercomparison is one of audit activities but it is performed in the spirit of collaboration and support rather than in the spirit of inspection. The aim of intercomparison of output measurement of 137 Cs irradiator is to verify the dose stated by the participant laboratories. Intercomparison is also to assess the competency of the participant, to keep traceability and consistency of measurement result, to assure that instrument work correctly and the result of evaluation was in agreement, and also for fulfilling one of the clauses of ISO-17025-2005. Besides that, this intercomparison aimed to facilitate link between the system and members of national measurement and transfer of experience in measurement technique and dose evaluation of radiation. The benefit of intercomparison is important among others as tests of proficiency in dose evaluation or measurement, upgrading quality of service and for obeying supervisor body legislation (BAPETEN). TLD was used as a means of output 137 Cs irradiator measurement, whereas film and TLD were used for dose intercomparison. This paper presented result of intercomparison of output measurement and evaluation of personal dose equivalent, Hp(10) in the year of 2006 to 2008 followed by 6 participants: Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Medan, Surabaya, Makasar, PTLR and Laboratory of Keselamatan dan Kesehatan Lingkungan (KKL)-PTKMR BATAN. In this intercomparison, the dose of TLD stated by participant were compared with the dose measured by Radiation Metrology Laboratory (LMR), and the results showed the differences were within 10 %, so it was satisfied. The results of intercomparison of personal dose equivalent, Hp(10) were evaluated based on ISO/IEC Guide 43-1, 1997 analysis and expressed as E n . The values of E n

  13. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2002-01-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  14. In vivo TLD-measurement of the radiation burden after intake of sup(99m)Tc-labelled compounds

    International Nuclear Information System (INIS)

    Kletter, K.; Frischauf, H.; Dudczak, R.; Nowotny, R.

    1978-01-01

    Organ and whole-body radiation doses by sup(99m)Tc labelled preparations were measured on patients subjected to scintigraphy of liver (+spleen), thyroid of kidneys. Body surface doses were determined by means of TLD-100 (LiF) dosimeters. From these values organ doses were calculated by inference from surface and organ measurements on a Remcal - Alderson phantom which also served to examine the influence of variable fat layers on the surface doses. The results were compared with data calculated from pharmacokinetic measurements of organ uptake as well as blood and urine activity. Both methods gave corresponding results. (author)

  15. Investigation of complexes with bone affinity using the In vivo generator system 166 Dy/166 Ho

    International Nuclear Information System (INIS)

    Pedraza L, M.

    2006-01-01

    The importance of this original research lies in the fact that it has proven that the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system is a stable complex that can be used as a therapeutic radiopharmaceutical. Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. Bone-seeking radiopharmaceuticals such as 166 Ho-DOTMP or 153 Sm-DTMP, have been proposed for delivering ablative radiation doses to marrow in multiple myeloma and other hematological malignancies or have shown excellent results in palliative bone metastasis pain therapy, respectively. As lanthanides have similar chemical characteristics the phosphonate with bone affinity (EDTMP) labeled with Dy/Ho can be used for marrow ablation while causing minimal irradiation to normal organs. This in vivo generator system has not been previously reported. The aim of this research was to label EDTMP (ethylene diamine tetramethylene phosphonate) with 166 Dy/ 166 Ho; to evaluate the in vitro and in vivo stability of both 166 Dy-EDTMP and 166 Ho-EDTMP complexes when the daughter 166 Ho is formed as a dysprosium decay product; to determine the bone marrow cytotoxic and genotoxic effect in mice and to evaluate, by histopathology, the myeloablative potential of the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system. 166 Dy was obtained by neutron irradiation of enriched 164 Dy 2 O 3 in a TRIGA Mark III reactor. Labeling was carried out in an aqueous phosphate medium at pH 8.0 by addition of 166 DyCl 3 to EDTMP at a molar ratio 1:1.75, with >99 % radiochemical purity, as determined by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). In vitro studies demonstrated that 166 Dy/ 166 Ho-EDTMP is unstable after dilution in saline but stable in human serum with no translocation of the daughter nucleus subsequent to β decay of 166 Dy, which could release free 166 Ho 3+ . Biodistribution in mice

  16. Luminescent properties in films of ZrO{sub 2}: Dy; Propiedades luminiscentes en peliculas de ZrO{sub 2}: Dy

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, R. C.; Guzman, J.; Rivera, T.; Ceron, P.; Montes, E.; Guzman, D. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Garcia H, M. [UNAM, Instituto de Investigaciones en Materiales, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Falcony, C. [IPN, Centro de Investigacion y de Estudios Avanzados, Apdo. Postal 14-740, 07000 Mexico D. F. (Mexico); Azorin, J., E-mail: rodmarolm@yahoo.com [Universidad Autonoma Metropolitana, Unidad Iztapala, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)

    2014-08-15

    In this work the luminescent characterization of zirconium oxide (ZrO{sub 2}) films impure with dysprosium (Dy{sup +3}) is reported, obtained by means of the ultrasonics spray pyrolysis technique. The films were deposited on glass substrates (Corning), in a temperatures interval of 400 to 550 grades C, using as precursor elements Zirconium oxide chloride octahydrate (ZrOCl{sub 2}·8H{sub 2}O) and Dysprosium tri-chloride (DyCl{sub 3}), dissolved in deionized water, varying the concentration of the contaminated from the 1 to 20 atomic % with relationship to the zirconium in solution. The luminescent characterization was analyzed by means of photoluminescence and thermoluminescence. The photoluminescence results showed a spectrum with three maxima which correspond to the electronic transitions {sup 4}F{sub 9/2} - {sup 6}H{sub 15/2}, {sup 4}F{sub 9/2} - {sup 6}H{sub 13/2} and {sup 4}F{sub 9/2} - {sup 6}H{sub 11/2} characteristics of the Dy{sup 3+} ion. The thermoluminescence (Tl) response when being exposed to a monochrome UV beam in 240 nm showed a wide curve that exhibits a maxim centered in 200 grades C. The Tl response of ZrO{sub 2}:Dy in function of the dose was shown lineal in the interval of 24 mJ/cm{sup 2} to 432 mJ/cm{sup 2}. A study of the repeatability and dissipation of the ZrO{sub 2}:Dy Tl response is included. Considering the shown previous results we can conclude that the ZrO{sub 2} in film form obtained by spray pyrolysis has luminescent properties in 240 nm. (Author)

  17. Effect of the temperature and relative humidity in dosemeters used for personnel monitoring

    International Nuclear Information System (INIS)

    Antonio Filho, J.

    1982-12-01

    The systematics of the combined effect of temperature and humidity on photographic dosimeters of the type Agfa-Gevaert, Kodak type II, III and the thermoluminescent dosimeters LiF:Mg,Ti (TLD-100, Harshaw), D-CaSO 4 :Dy-0,4 (Teledyne), e CaSO 4 :Dy+NaCl (IPEN), used in personal monitoring in Brazil was investigated, in the temperature range of 20 0 C to 50 0 C and relative humidity of 65% to 95%, in order to determine the best manner of utilization of these detectors in Brazilian climatic conditions. The dosimeters were studied in different forms of packing-sheet such as aluminezed paper and polyethylene. For the determination of the systematics, the dosimeters were irradiated in three conditions: before, during and after of storage in climatic chambers to a maximum period of 60 days. It was found that the dosimetric filmes and thermoluminescent dosimeter CaSO 4 :Dy+NaCl without protection, presented a high dependence to temperature and humidity, and when protected presented good results. Therefore, the best manner of utilization of these monitors in environments with relative humidity and temperature greater them 75% and 30 0 C respectively, is achieved with the protection of aluminized paper. The LiF:Mg,Ti and D+CaSO 4 :Dy-0,4 dosimeters can be utilized in their original form because they presented low dependence with humidity and temperature in the range studied. (Author) [pt

  18. Experimental comparison of profiles of acquired small fields with ionization chambers, diodes, radiochromic s and TLD films; Comparacion experimental de perfiles de campos pequenos adquiridos con camaras de ionizacion, diodos, peliculas radiocromicas y TLD

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, D.; Garrigo, E. [Instituto Privado de Radioterapia, Obispo Oro 423, X5000BFI Cordoba (Argentina); Filipuzzi, M. [Instituto Balseiro, Centro Atomico Bariloche, Av. Bustillo 9500, 8400 Bariloche - Rio Negro (Argentina); Germanier, A., E-mail: devenencia@radioncologia-zunino.org [Centro de Excelencia en Productos y Procesos, Santa Maria de Punilla, 5164 Cordoba (Argentina)

    2014-08-15

    The use of radiation small fields, introduced by new techniques, can bring a considerable uncertainty in the precision of the acquired profiles, due to the conditions of lateral electronic non-equilibrium and the perturbations introduced by the detectors (volume effect and alteration of the charged particles flowing) [Das et al., 2007]. The development of new miniature detectors looks to diminish the uncertainty created by the material and the size of the sensitive volume of the dosimeter. For this reason, comparative measurements for three sizes of square field were carried out (20 mm, 10 mm and 5 mm, of side) using a detectors series: 3 ionization chambers (PTW-31003, IBA-CC04, PTW-31016), 2 diodes (PTW-60012, IBA-Sfd), thermoluminescent detectors micro-cubes of 1 mm of edge (TLD-700) and radiochromic s films EBT-3. These last two were used as reference detectors, due to their spatial high resolution and similar performance with Monte Carlo simulations [Francescon et al., 1998]. So much the thermoluminescent detectors as the radiochromic films resolved the profiles in a similar way. Both diodes responded correctly, but the rest of the detectors overestimated the gloom of the fields, which allows conclude that the used TLD (and both diodes) can resolve field sizes correctly, usually utilized in radio-surgery, without producing significant alterations in the acquired data. (author)

  19. Synthesis and luminescence characteristics of Dy{sup 3+} doped KLa(PO{sub 3}){sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Chemingui, S.; Ferhi, M., E-mail: ferhi.mounir@gmail.com; Horchani-Naifer, K.; Férid, M.

    2015-10-15

    Polycrystalline powders of KLa{sub (1−x)}Dy{sub x}(PO{sub 3}){sub 4} (x=0.5%, 1%, 5% and 10%) with linear chain have been grown by solid state reaction. The obtained powders are characterized by X-ray powder diffraction, FTIR and Raman spectroscopies. Emission, excitation spectra and decay curves analysis have been used to study the spectroscopic properties of Dy{sup 3+} in KLa(PO{sub 3}){sub 4}. The photoluminescence spectra show two characteristic blue and yellow bands of Dy{sup 3+}. The yellow-to-blue emission intensity ratios and CIE chromaticity coordinates have been determined from emission spectra to evaluate the emitted light as function of Dy{sup 3+} concentration. The measured decay rates for {sup 4}F{sub 9/2}→{sup 6}H{sub 15/2} deviated from exponential to non-exponential shape with increase of Dy{sup 3+} concentration. The observed non-exponential behavior of the decay curve has been fitted to Inokuti–Hirayama model, which indicates that the energy transfer between the donor and the acceptor is of dipole–dipole nature. The energy transfer, between the donor (excited Dy{sup 3+}) and the acceptor (unexcited Dy{sup 3+}), increases with Dy{sup 3+} ions concentration. - Highlights: • Polycrystalline powders of KLa{sub (1−x)}Dy{sub x}(PO{sub 3}){sub 4} were grown by solid state reaction. • The obtained samples are characterized by XRD, FTIR and Raman spectroscopies. • The luminescent properties of Dy{sup 3+} in KLa(PO{sub 3}){sub 4} are investigated. • Lifetime and chromatic coordinates depend strongly on Dy{sup 3+} concentration. • White and blue emissions are obtained at high and low concentration, respectively.

  20. Blue–green afterglow of BaAl{sub 2}O{sub 4}:Dy{sup 3+} phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Bao-gai [School of Mathematics and Physics, Changzhou University, Jiangsu 213164 (China); Ma, Qing-lan [School of Mathematics and Physics, Changzhou University, Jiangsu 213164 (China); School of Electronics and Information, Nantong University, Jiangsu 226019 (China); Xiong, Rui [School of Physics and Technology, Wuhan University, Hubei 430072 (China); Li, Xiazhang [Analysis and Testing Center, Changzhou University, Jiangsu 213164 (China); Huang, Yuan Ming, E-mail: dongshanisland@126.com [School of Mathematics and Physics, Changzhou University, Jiangsu 213164 (China)

    2016-03-15

    Highlights: • Afterglow can be achieved when Eu{sup 2+} is absent in the DyAl{sub 2}O{sub 4}:Dy{sup 3+} phosphors. • The afterglow of DyAl{sub 2}O{sub 4}:Dy{sup 3+} phosphors is discernible to naked eyes for minutes. • Dy{sup 3+} introduced trap centers are believed to be responsible for the afterglow. - Abstract: Dy{sup 3+} doped barium aluminate (BaAl{sub 2}O{sub 4}:Dy{sup 3+}) phosphors were prepared via the sol–gel combustion route at the ignition temperature of 600 °C. The phosphors were characterized with X-ray diffractometry, scanning electron microscopy, transmission electron microscopy, photoluminescence spectroscopy, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Regardless of the absence of Eu{sup 2+} luminescent centers, broadband blue–green afterglow with its peak at about 490 nm was recorded in the BaAl{sub 2}O{sub 4}:Dy{sup 3+} phosphors. The decay profile of the blue–green afterglow can be best fitted into a two-component exponential function with the two lifetime decay constants to be 8.81 and 45.25 s, respectively. The observation of blue–green afterglow from BaAl{sub 2}O{sub 4}:Dy{sup 3+} in the absence of Eu{sup 2+} provides unique opportunity in unveiling the afterglow mechanisms of rare-earth doped alkaline-metal aluminates. Possible mechanisms on the blue–green afterglow in BaAl{sub 2}O{sub 4}:Dy{sup 3+} phosphors are discussed in terms of the Dy{sup 3+} ions introduced trap centers as well as luminescent centers in the crystal lattice.