  1. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    Science.gov (United States)

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  2. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  3. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns......, psychological morbidity, and shocks has not been systematically investigated. We examined the relative importance of experienced shocks versus subjective concerns about the ICD as determinants of anxiety and depressive symptoms in ICD patients....

  4. Wearable cardioverter defibrillator: A life vest till the life boat (ICD arrives

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2014-01-01

    Full Text Available It is well established that implantable cardioverter defibrillator (ICD is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation of an ICD while the patient can still be at a risk of demise due to a life threatening ventricular arrhythmia. There could also be a temporary indication for protection while explanting an infected ICD system. The wearable cardioverter defibrillator (WCD is a device which comes to the rescue in such situations. In this brief review, we discuss the historical aspects of the development of a WCD, technical aspects as well as the clinical trial data and real world scenario of its use.

  5. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  6. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  7. Gender differences in anxiety and concerns about the cardioverter defibrillator

    DEFF Research Database (Denmark)

    Spindler, Helle; Johansen, Jens B; Andersen, Kirsten Krogh

    2009-01-01

    Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance.......Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance....

  8. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabil...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs....... of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196...

  9. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  10. Daily remote monitoring of implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Hindricks, Gerhard; Varma, Niraj; Kacet, Salem

    2017-01-01

    Aims: Remote monitoring of implantable cardioverter-defibrillators may improve clinical outcome. A recent meta-analysis of three randomized controlled trials (TRUST, ECOST, IN-TIME) using a specific remote monitoring system with daily transmissions [Biotronik Home Monitoring (HM)] demonstrated...

  11. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis.

    Science.gov (United States)

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes.

  12. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  13. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  14. Depressive symptoms in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Andersen, Christina M; Denollet, Johan

    2018-01-01

    OBJECTIVE: Patients with an implantable cardioverter defibrillator (ICD) and co-morbid depression are at greater risk of poor quality of life and premature death. We examined if treatment expectations predict depressive symptoms 12months post implant. METHODS: First-time implant patients from...... of 12-months depressive symptoms: Model 1: Negative treatment expectations (β=0.202; p=0.020) and baseline depression (β=0.376; pdepression (β=0.350; p....051). Model 3: Baseline depression (β=0.353; p

  15. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen

    2009-01-01

    that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use......AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...

  16. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  17. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating in...

  18. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  19. Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing

    Czech Academy of Sciences Publication Activity Database

    Ebrille, E.; Konecny, T.; Konecny, D.; Špaček, R.; Jones, P.; Ambrož, Pavel; DeSimone, C.V.; Powel, B.D.; Hayes, D.L.; Friedman, P.A.; Asirvatham, S.J.

    2015-01-01

    Roč. 90, č. 2 (2015), s. 202-208 ISSN 0025-6196 Institutional support: RVO:67985815 Keywords : geomagnetic activity * implantable cardioverter defibrillator Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 5.920, year: 2015

  20. Driving safety among patients with automatic implantable cardioverter defibrillators.

    Science.gov (United States)

    Finch, N J; Leman, R B; Kratz, J M; Gillette, P C

    1993-10-06

    To determine the driving behavior of patients following the placement of automatic implantable cardioverter defibrillators (AICDs). Forty patients with AICDs (33 men, seven women; mean age, 62.7 years) responded to a questionnaire designed to ascertain driving behavior after hospital discharge. Despite medical advice never to drive again, 28 patients (70%) resumed driving, with the majority doing so by 8 months after AICD implantation. Of these, 11 (40%) identified themselves as the primary driver in their household. Fourteen (50%) drove daily. Two (7%) were driving and continued to drive during discharge of their AICDs. Twenty-five (91%) reported that they felt comfortable and safe while driving. A majority of patients with AICDs continue to drive after a proscription of this activity by health care workers.

  1. Psychological distress in patients with an implantable cardioverter defibrillator

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Shiga, MD

    2013-12-01

    Full Text Available Despite the effectiveness of an implantable cardioverter defibrillator (ICD, its implantation and concomitant therapies, including shocks, can induce psychological distress in patients. Depression has been observed in approximately 30% of ICD patients, and shocks may contribute to the persistence of depression. Anxiety is common, with reports of 24–87% of ICD patients experiencing symptoms of anxiety after implantation, and type D personality and ICD-related concerns may play important roles in the level of anxiety in ICD patients. However, the association between ICD shocks and anxiety is controversial. The prevalence of posttraumatic stress disorder (PTSD in ICD patients is approximately 20%, and type D personality, comorbidities, and frequent shocks may contribute to PTSD. It is also important to pay attention to the psychological distress in the partners of ICD patients.

  2. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  4. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  5. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  6. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    Patients implanted with a cardioverter defibrillator (ICD) who are suffering from refractory angina pectoris could benefit from spinal cord stimulation (SCS) due to the well-documented pain relieving effect. However, the combined treatment remains controversial. The aim of the study is to report...... successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... for refractory angina pectoris can be performed in patients implanted with cardioverter defibrillators without interference. However, individual testing during implantation or re-programming the devices is mandatory in order to assess optimal safety in each patient....

  7. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  8. Guidelines on the management of implantable cardioverter defibrillators at the end of life.

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  9. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    Science.gov (United States)

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G

  10. Congenital short QT syndrome and implantable cardioverter defibrillator treatment: inherent risk for inappropriate shock delivery.

    Science.gov (United States)

    Schimpf, Rainer; Wolpert, Christian; Bianchi, Francesca; Giustetto, Carla; Gaita, Florenzo; Bauersfeld, Urs; Borggrefe, Martin

    2003-12-01

    A congenital short QT interval constitutes a new primary electrical abnormality associated with syncope and/or sudden cardiac death. We report on the initial use of implantable cardioverter defibrillator (ICD) therapy in patients with inherited short QT interval and discuss sensing abnormalities and detection issues. In five consecutive patients from two unrelated European families who had structurally normal hearts, excessively shortened QT intervals, and a strong positive family history of sudden cardiac death, ICDs were placed for primary and secondary prevention. Mean QT intervals were 252 +/- 13 ms (QTc 287 +/- 13 ms). Despite normal sensing behavior during intraoperative and postoperative device testing, 3 of 5 patients experienced inappropriate shock therapies for T wave oversensing 30 +/- 26 days after implantation. Programming lower sensitivities and decay delays prevented further inappropriate discharges. The congenital short QT syndrome constitutes a new clinical entity with an increased risk for sudden cardiac death. Currently, ICD treatment is the only therapeutic option. In patients with short QT interval and implanted ICD, increased risk for inappropriate therapy is inherent due to the detection of short-coupled and prominent T waves. Careful testing of ICD function and adaptation of sensing levels and decay delays without sacrificing correct arrhythmia detection are essential.

  11. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  12. Clinical performance of different DF-4 implantable cardioverter defibrillator leads.

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.

  13. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  14. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  15. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2014-01-01

    UNLABELLED: The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow-up ...

  16. Implantable cardioverter defibrillator therapy for prevention of sudden cardiac death in children in the Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; van de Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; ten Harkel, A. Derk Jan

    2010-01-01

    INTRODUCTION: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. METHODS AND RESULTS: From 1995 to 2006, 45

  17. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery

  18. Implantable Cardioverter Defibrillator Therapy for Prevention of Sudden Cardiac Death in Children in The Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; Van De Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; Ten Harkel, A. Derk Jan

    Introduction: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. Methods and Results: From 1995 to 2006, 45

  19. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatme......, and (b) whether patients not treated for their emotional distress reported poorer health status using a prospective study design....

  20. Experiences of patients with implantable cardioverter defibrillator in Turkey: A qualitative study

    Directory of Open Access Journals (Sweden)

    Özgür Aslan

    2012-01-01

    Full Text Available Background. There has been an increase in the number of patients with implantable cardioverter defibrillator (ICD. It isimportant to understand ICD patients’ experiences with it.Aim. The aim of this study was to describe experiences of patients with implantable cardioverter defibrillator (ICD.Methodology. A qualitative approach was used. Focus group interviews were used to obtain data from 19 patients whowere implanted cardioverter defibrillator at two centers in Izmir, Turkey. The patients were assigned into four groups. Thedata was analyzed using qualitative content analysis.Results. The analysis revealed six main themes: activities of daily living, social life, familial relationships, emotionalchanges, implantable cardioverter defibrillator shocks and experiences with receiving information and counselling fromhealth care providers.Conclusions. It can be concluded that patients with ICD experience physical and psychological problems and are not offeredthe education they need. To reduce the fears of the patients and their families and to prepare them for possible life stylechanges, comprehensive training programs that start in the pre-implantation period and continue into the post-implantationperiod should be organized.

  1. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  2. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  3. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    Objective We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. Methods A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] y...

  4. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    AIMS: This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: Between February 2011 and July 2013, 107...

  5. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

    Science.gov (United States)

    Chongtham, Dhanaraj Singh; Bahl, Ajay; Kumar, Rohit Manoj; Talwar, K K

    2007-05-31

    We report a patient with hypertrophic cardiomyopathy who received an inappropriate implantable cardioverter defibrillator shock due to electrical interference from a washing machine. This electrical interference was detected as an episode of ventricular fibrillation with delivery of shock without warning symptoms.

  6. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  7. Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

    Directory of Open Access Journals (Sweden)

    U. Boles

    2018-03-01

    Full Text Available Background: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs to minimize inappropriate therapies (ITS, but this has not been completely successful. Aim: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. Method: A retrospective single-centre analysis of 250 patients with either dual chamber (DR ICDs or biventricular ICDs (CRTDs over a (41.9 ± 27.3 month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. Results: 39 events of anti-tachycardial pacing (ATP and/or shocks were identified in 20 patients (8% incidence rate among patients. The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%. Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43% of the secondary indication group experienced inappropriate therapies. Conclusions: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation. Keywords: Implantable cardioverter-defibrillator (ICDs, Inappropriate therapies, Standardized programming

  8. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Cohen, Jennifer D; Costa, Heather S; Russo, Robert J

    2012-12-01

    Conventional pacemaker and implantable cardioverter-defibrillator product labeling currently cautions against exposure to magnetic resonance imaging (MRI). However, there is a growing clinical need for MRI, without an acceptable alternative imaging modality in many patients with cardiac devices. The purpose of this study was to determine the risk of MRI at 1.5 T for patients with cardiac devices by measuring the frequency of device failures and clinically relevant device parameter changes. Data from a single-center retrospective review of 109 patients with pacemakers and implantable cardioverter-defibrillators (the MRI group) who underwent 125 clinically indicated MRI studies were compared to data from a prospective cohort of 50 patients with cardiac devices who did not undergo MRI (the control group). In the MRI group, there were no deaths, device failures requiring generator or lead replacement, induced arrhythmias, losses of capture, or electrical reset episodes. Decreases in battery voltage of ≥0.04 V occurred in 4%, pacing threshold increases of ≥0.5 V in 3%, and pacing lead impedance changes of ≥50 Ω in 6%. Although there were statistically significant differences between the MRI and control groups for the mean change in pacing lead impedance (-6.2 ± 23.9 vs 3.0 ± 22.1 Ω) and left ventricular pacing threshold (-0.1 ± 0.3 vs 0.1 ± 0.2 V), these differences were not clinically important. In conclusion, MRI in patients with cardiac devices resulted in no device or lead failures. A small number of clinically relevant changes in device parameter measurements were noted. However, these changes were similar to those in a control group of patients who did not undergo MRI. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. "Real life" longevity of implantable cardioverter-defibrillator devices.

    Science.gov (United States)

    Manolis, Antonis S; Maounis, Themistoklis; Koulouris, Spyridon; Vassilikos, Vassilios

    2017-09-01

    Manufacturers of implantable cardioverter-defibrillators (ICDs) promise a 5- to 9-year projected longevity; however, real-life data indicate otherwise. The aim of the present study was to assess ICD longevity among 685 consecutive patients over the last 20 years. Real-life longevity of ICDs may differ from that stated by the manufacturers. The study included 601 men and 84 women (mean age, 63.1 ± 13.3 years). The underlying disease was coronary (n = 396) or valvular (n = 15) disease, cardiomyopathy (n = 220), or electrical disease (n = 54). The mean ejection fraction was 35%. Devices were implanted for secondary (n = 562) or primary (n = 123) prevention. Single- (n = 292) or dual-chamber (n = 269) or cardiac resynchronization therapy (CRT) devices (n = 124) were implanted in the abdomen (n = 17) or chest (n = 668). Over 20 years, ICD pulse generator replacements were performed in 238 patients (209 men; age 63.7 ± 13.9 years; ejection fraction, 37.7% ± 14.0%) who had an ICD for secondary (n = 210) or primary (n = 28) prevention. The mean ICD longevity was 58.3 ± 18.7 months. In 20 (8.4%) patients, devices exhibited premature battery depletion within 36 months. Most (94%) patients had none, minor, or modest use of ICD therapy. Longevity was longest for single-chamber devices and shortest for CRT devices. Latest-generation devices replaced over the second decade lasted longer compared with devices replaced during the first decade. When analyzed by manufacturer, Medtronic devices appeared to have longer longevity by 13 to 18 months. ICDs continue to have limited longevity of 4.9 ± 1.6 years, and 8% demonstrate premature battery depletion by 3 years. CRT devices have the shortest longevity (mean, 3.8 years) by 13 to 17 months, compared with other ICD devices. These findings have important implications, particularly in view of the high expense involved with this type of electrical

  10. “Atrial torsades de pointes” Induced by Low-Energy Shock From Implantable-Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Ilknur Can, MD

    2013-09-01

    Full Text Available A 58 year-old-patient developed an episode of polymorphic atrial tachycardia which looked like "atrial torsades de pointes" after a 5J shock from implantable cardioverter defibrillator.

  11. Implantable cardioverter-defibrillator explantation for overdiagnosed or overtreated congenital long QT syndrome.

    Science.gov (United States)

    Gaba, Prakriti; Bos, J Martijn; Cannon, Bryan C; Cha, Yong-Mei; Friedman, Paul A; Asirvatham, Samuel J; Ackerman, Michael J

    2016-04-01

    Primary treatment of long QT syndrome (LQTS) currently consists of beta-blocker therapy, although an implantable cardioverter-defibrillator (ICD) is considered for high-risk patients. However, both overdiagnosis and overtreatment must be avoided because their sequelae can be significant. The purpose of this study was to evaluate the prevalence and details of ICD explants in a cohort of patients from a tertiary genetic heart rhythm clinic for a previously rendered diagnosis of LQTS. Overall, 1227 consecutive patients were included in the study. All patients had been referred to the Mayo Clinic for evaluation of possible LQTS and subsequently were either diagnosed with LQTS or dismissed as normal. Further stratification of patients was conducted to assess how many patients had an ICD and how many had a subsequent ICD explant. In total, 170 patients (14%) had an ICD, including 157 of 670 patients (23%) with confirmed LQTS and 13 of 557 patients (2%) who did not have LQTS. Among these, 12 of 1227 (1%) had the ICD removed: 7 of 157 LQTS patients (4.5%) compared to 5 of 14 non-LQTS patients (36%). Before explant, 5 of 12 patients (42%) experienced inappropriate shocks, ranging from 2 to as many as 54 shocks. In addition, 4 had a device-related infection, and 9 had device malfunction (including lead dysfunction or fracture). None of these patients had a breakthrough cardiac event since removal of their ICD during 5.5 ± 3.5 years of follow-up. Implications of overdiagnosis and overtreatment are profound because unnecessary ICD placement can be associated with infection, malfunction, inappropriate shocks, and subsequent anxiety. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  13. Spiritual well-being may buffer psychological distress in patients with implantable cardioverter defibrillators (ICD)

    OpenAIRE

    Salmoirago-Blotcher, Elena; Crawford, Sybil; Tran, Chau; Goldberg, Robert; Rosenthal, Lawrence; Ockene, Ira

    2012-01-01

    Psychological distress is common in patients with implantable cardioverter defibrillators (ICDs) and has been associated with a worse prognosis. The authors examined whether spiritual wellbeing is associated with reduced psychological distress in patients with ICDs. The Functional Assessment of Chronic Illness Therapy-Spiritual Wellbeing (FACIT-SWB) questionnare and the Hospital Anxiety and Depression Scale (HADS) were used to measure spiritual wellbeing and overall psychological distress. Mu...

  14. Symptomatic heart failure is the most important clinical correlate of impaired quality of life, anxiety, and depression in implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Johansen, Jens B; Pedersen, Susanne S.; Spindler, Helle

    2008-01-01

    To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD).......To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD)....

  15. Psychological and clinical problems in young adults with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wójcicka, Mariola; Lewandowski, Michał; Smolis-Bak, Edyta; Szwed, Hanna

    2008-10-01

    Implantable cardioverter-defibrillators (ICD) are the most effective treatment in patients with the risk of sudden cardiac death. ICD improves patients' safety but is also the source of numerous inconveniences. Especially young people consider such ICD-related inconveniences as most unwelcome. To assess the quality of life and main psychological problems encountered in young adults with an ICD. We studied 45 subjects aged 14-29 years (mean 21.2+/-4.3). ICDs were used in primary prevention in 22 patients, and in secondary prevention in 23 patients. Time elapsed from implantation ranged from 5 months to 11 years (4.3+/-2.7 years). Since the problems affecting this group were rather specific, the patients' quality of life was assessed with a special questionnaire addressing important issues and problems associated with living with an ICD. ICD discharges were observed in 67.4% of patients (primary prevention - 45.5%, secondary prevention - 82.6%), multiple shocks in 47.2%, and phantom shocks in 21.4%. Anxiety associated with an ICD discharge was reported by 84.4% of patients. In order to prevent ICD discharges, 53.3% of patients decreased their activity. Problems with memory were observed in 42.2% of patients, with concentration in 47.6%, and with sleep in 42.2%. Almost half of those over 18 years of age were active drivers. None of the subjects experienced an ICD discharge during sexual intercourse. None of the men reported any sexual problems, while seven (41.2%) women did. Almost a quarter of the patients claimed to have had complications after the implantation. Young adult patients generally were compliant to have their ICD checked and accepted their limitations and disease. Fewer people assessed their health status as bad. Some patients in the group studied found it extremely difficult to accept their disease and/or ICD and to adapt to the situation. As many as nine patients believed the ICD implantation had been unnecessary, seven did not accept the ICD, three

  16. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  17. The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

    Science.gov (United States)

    2013-01-01

    Background To test the hypothesis that the oral cavity is a potential source for implantable pacemaker and cardioverter defibrillators infections, the bacterial diversity on explanted rhythm heart management devices was investigated and compared to the oral microbiome. Methods A metagenomic approach was used to analyze the bacterial diversity on the surfaces of non-infected and infected pacemakers. The DNA from surfaces swaps of 24 non-infected and 23 infected pacemaker were isolated and subjected to bacterial-specific DNA amplification, single strand conformation polymorphism- (SSCP) and sequencing analysis. Species-specific primer sets were used to analyze for any correlation between bacterial diversity on pacemakers and in the oral cavity. Results DNA of bacterial origin was detected in 21 cases on infected pacemakers and assigned to the bacterial phylotypes Staphylococcus epidermidis, Propionibacterium acnes, Staphylococcus aureus, Staphylococcus schleiferi and Stapyhlococcus. In 17 cases bacterial DNA was found on pacemakers with no clinical signs of infections. On the basis of the obtained sequence data, the phylotypes Propionibacterium acnes, Staphylococcus and an uncultured bacterium were identified. Propionibacterium acnes and Staphylococcus epidermidis were the only bacteria detected in pacemeaker (n = 25) and oral samples (n = 11). Conclusions The frequency of the coincidental detection of bacteria on infected devices and in the oral cavity is low and the detected bacteria are highly abundant colonizers of non-oral human niches. The transmission of oral bacteria to the lead or device of implantable pacemaker or cardioverter defibrillators is unlikely relevant for the pathogenesis of pacemaker or cardioverter defibrillators infections. PMID:23575037

  18. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  19. [Nurses and doctors in the management of arrhytmic complications: the case of electric storm in patients with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Plebani, Laura; Occhetta, Eraldo

    2006-01-01

    The evolution of arrhythmologic technology introduced new therapeutic opportunities for cardiology patients. Competence, continuity of care, integration and collaboration between medical doctors and nurses allow a safe management of short and long term complications. A typical example of a new arrhythmic complication is the "electrical storm" or "arrhythmic warm up" in patients implanted with a cardioverter-defibrillator (ICD). The definition and epidemiology of the electrical storm stress the relevance of this clinical situation; its dramatic emergency involves several aspects of nursing care, clinical, prognostic, ethical and deontological. The definition and implementation of an integrated protocol for the treatment of this condition is described and ethical and unresolved questions are rised. One of these problems is the recommendation to offer the patient the opportunity to receive information about the option of inactivating the ICD.

  20. Safety of sports participation in patients with implantable cardioverter defibrillators: a survey of heart rhythm society members.

    Science.gov (United States)

    Lampert, Rachel; Cannom, David; Olshansky, Brian

    2006-01-01

    Safety of Sports for ICD Patients. The safety of sports participation for patients with implantable cardioverter defibrillators (ICDs) is unknown, and recommendations among physicians may vary widely. The purposes of this study were to determine current practice among patients with ICDs and their physicians regarding sports participation, and to determine how many physicians have cared for patients who have sustained adverse events during sports participation. A survey was mailed to all 1,687 U.S. physician members of the Heart Rhythm Society. Among 614 respondent physicians, recommendations varied widely. Only 10% recommended avoidance of all sports more vigorous than golf. Seventy-six percent recommended avoidance of contact, and 45% recommend avoidance of competitive sports. Most (71%) based restrictions on patients' underlying heart disease. Regardless of recommendations, most physicians (71%) reported caring for patients who participated in sports, including many citing vigorous, competitive sports, most commonly cited were basketball, running, and skiing. ICD shocks during sports were common, cited by 40% of physicians. However, few adverse consequences were reported. One percent of physicians reported known injury to patient (all but 3 minor); 5%, injury to the ICD system, and weightlifting and golf. Physician recommendations for sports participation for patients with ICDs varies widely. Many patients with ICDs do participate in vigorous and even competitive sports. While shocks were common, significant adverse events were rare.

  1. Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT) : Registry design and baseline characteristics of a prospective observational cohort study to predict appropriate indication for implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Van Barreveld, M. (M.); M.G.W. Dijkgraaf (Marcel); Hulleman, M. (M.); L. Boersma (Lucas); P.P.H.M. Delnoy (Peter Paul); M. Meine (Mathias); Tuinenburg, A.E. (A. E.); D.A.M.J. Theuns (Dominic); P. van der Voort (Pepijn); G-J.P. Kimman (Geert-Jan); E. Buskens (Erik); Tijssen, J.P.G. (J. P.G.); Bruinsma, N. (N.); Verstraelen, T.E. (T. E.); A.H. Zwinderman (Ailko); Van Dessel, P.H.F.M. (P. H.F.M.); A.A.M. Wilde (Arthur)

    2017-01-01

    textabstractBackground Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will

  2. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  3. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  4. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  5. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether...... patients with a lead subject to a device advisory report poorer PROs than non-advisory controls....

  6. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  7. Emotions and health: findings from a randomized clinical trial on psychoeducational nursing to patients with implantable cardioverter defibrillator.

    Science.gov (United States)

    Kikkenborg Berg, Selina; Støier, Louise; Moons, Philip; Zwisler, Ann-Dorthe; Winkel, Per; Ulrich Pedersen, Preben

    2015-01-01

    Serious illness will inevitably lead to a fundamental emotional reaction. Traditionally, in interventional treatment or rehabilitation trials, the psychological status of patients with implantable cardioverter defibrillators has been evaluated with anxiety and depression as outcome measures. In caring for these patients, the aim of nursing is to help patients manage life with complex heart disease. The early detection and management of negative emotional response might prevent the development of pathological conditions such as depression. The aims of this study were to (a) describe the trajectory of primary emotions over time in patients with implantable cardioverter defibrillators and (b) examine the potential effects of psychoeducational nursing on primary emotions. During the inclusion period (October 2007 to November 2009), 196 patients with implantable cardioverter defibrillator were randomized (1:1) to rehabilitation versus usual care. Rehabilitation consisted of a psychoeducational nursing component and an exercise training component. This article concerns phase 1, psychoeducational nursing, guided by a theory of nursing, Rosemary Rizzo Parses Human Becoming Practice Methodologies. The outcome measure is the Emotions and Health Scale. The scale consists of 8 primary emotions: joy, agreeableness, surprise, fear, sadness, disgust, anger, and anticipation. Mean (SD) age was 58 (13) years, and 79% of the participants were men. Significant improvements were found in primary emotional responses over time (P .05). Primary emotions are affected after implantable cardioverter defibrillator implantation. Improvements over time were found. However, it was not possible to detect any effect of a short-term psychoeducational nursing intervention. Evaluating the primary emotions might be a good way for nurses to monitor patients' psychological outcomes because the instrument is sensitive to changes over a short period. Further development of early psychoeducational nursing

  8. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication

    NARCIS (Netherlands)

    Quast, Anne-Floor B. E.; Tjong, Fleur V. Y.; Koop, Brendan E.; Wilde, Arthur A. M.; Knops, Reinoud E.; Burke, Martin C.

    2018-01-01

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and

  9. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  10. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac...... patients, in general, and patients with an implantable cardioverter defibrillator (ICD), in particular. We investigated the association between statin therapy and symptoms of anxiety and depression and patients' health status during the 12 months after implantation, reckoning with statin type and dosage...... of statin type, dosage, and other potential confounders. The associations between statin therapy and depression (p = 0.06) and statin therapy and physical functioning (p = 0.05) were borderline significant, and no association was found with anxiety (p >0.05). In conclusion, statin therapy was associated...

  11. The Subcutaneous Implantable Cardioverter-Defibrillator: A Practical Review and Real-World Use and Application

    Directory of Open Access Journals (Sweden)

    Mark E. Panna Jr, MD, FACC, FHRS

    2016-02-01

    Full Text Available The subcutaneous implantable cardioverter-defibrillator (ICD is a novel technology using a subcutaneous (extrathoracic system for treatment of potential lethal ventricular arrhythmias. It avoids many of the risks of transvenous ICD implantation. It may be considered in patients having an ICD indication who do not have a pacing and/or cardiac resynchronization therapy indication, and who are unlikely to benefit from antitachycardia pacing therapy. We review patient selection, system components, the implantation technique, and screening considerations for subcutaneous ICD implantation. Its uses in specific patient populations, including children, patients with congenital heart disease, hypertrophic cardiomyopathy, or end-stage renal disease, and patients with preexisting pacemakers, are highlighted. Areas of future investigation are reviewed, including potential use with leadless pacing and magnetic resonance imaging.

  12. Electroconvulsive therapy in patients with cardiac pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Dolenc, Tamara J; Barnes, Roxann D; Hayes, David L; Rasmussen, Keith G

    2004-09-01

    Electroconvulsive therapy (ECT) is used to treat major depressive illness, especially in elderly and medically frail patients. Not uncommonly, these patients have cardiac pacemakers or implantable cardioverter defibrillators (ICDs). Only a few case reports in the literature describe the use of ECT in such patients. Herein we review our ECT experience treating 26 pacemaker patients and 3 ICD patients. All patients obtained significant antidepressant benefits with ETC. Only one serious cardiac event occurred, a case of supraventricular tachycardia (SVT) requiring a stay on the cardiac intensive care unit. The SVT resolved and the patient went on to receive further uncomplicated ECT treatments. We conclude from this experience that with proper pre-ECT cardiac and pacemaker/defibrillator assessment, ECT can be safely and effectively administered to patients with an implanted cardiac device.

  13. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  14. Trajectories of Patient-Reported Health Status in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Denollet, Johan; Versteeg, Henneke

    2015-01-01

    , no use of ACE inhibitors, psychotropic medication, negative affectivity, and type D personality were identified as independent determinants of poorer mental health status. In conclusion, the population with an ICD seems to be heterogeneous in terms of patient-reported physical and mental health status......To date, no study has assessed the course of patient-reported health status in patients with an implantable cardioverter defibrillator (ICD). Studying health status trajectories and their baseline determinants would permit the identification of patients at risk for poor health outcomes after ICD...... implantation. A combined cohort of 1,222 patients with an ICD (79% men; age = 61.4 [11.2] years) completed the 12-Item Short-Form Health Survey at baseline and 2 to 3 months and 12 to 14 months after implantation. Latent class analyses were used to identify trajectories and predictors of health status over...

  15. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  16. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  17. Illness perceptions in patients with heart failure and an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Timmermans, I.; Versteeg, H.; Meine, Mathias M

    2017-01-01

    Background Patients' illness perceptions are associated with psychological wellbeing and can be measured with the Brief Illness Perception Questionnaire (B-IPQ). However, little is known about illness perceptions in patients with heart failure. We examined the dimensional structure, validity...... and clinical and psychological correlates of the B-IPQ in Dutch, French and German patients with heart failure and an implantable cardioverter defibrillator (ICD). Method European heart failure patients (n=585) participating in the REMOTE-CIED study completed a set of questionnaires 1–2weeks post ICD.......69, with the ‘Consequences’ subscale being more internally consistent (α=0.80). Both the B-IPQ and its ‘Consequences’ subscale were significantly correlated with a number of psychological characteristics, but not with clinical characteristics. Multivariable logistic regression analysis indicated that threatening illness...

  18. Patients' perspective on deactivation of the implantable cardioverter-defibrillator near the end of life

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Chaitsing, Rismy; Szili-Torok, Tamas

    2013-01-01

    (67%) completed the survey. Most patients (68%) were aware that it is possible to turn the ICD off, and 95% believed it is important to inform patients about the possibility. Of the patients completing the survey, 84% indicated a choice for or against deactivation. Psychological morbidity......Recent guidelines have emphasized the importance of discussing the issue of deactivation near the end of life with patients with an implantable cardioverter-defibrillator (ICD). Few studies have examined the patient perspective and patients' wishes. We examined patients' knowledge and wishes...... for information; and the prevalence and correlates of a favorable attitude toward deactivation. Three cohorts of ICD patients (n = 440) extracted from our institutional database were asked to complete a survey that included a vignette about deactivation near the end of life. Of the 440 patients approached, 294...

  19. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... analyzed. In adjusted analyses, significant associations (standard deviation of normal-to-normal [NN] intervals [SDNN]: p = .043; standard deviation of NN intervals over 5-min periods [SDANN]: p = .010) and a trend (HRV triangular index: p = .09) were found for Type D personality, and trends were found...... = .043). A Benjamini-Hochberg correction for multiple testing led to reduction of the number of significant relationships, but there was still support for lower autonomic control patients with Type D personality and depression. Future research with larger sample sizes is warranted....

  20. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender...... disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  1. Ventricular tachyarrhythmias and mortality in patients with an implantable cardioverter defibrillator: impact of depression in the MIDAS cohort.

    Science.gov (United States)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc; Theuns, Dominic A M J; Pedersen, Susanne S

    2014-01-01

    We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause mortality during a median follow-up period of 3.8 years. Of all patients, 108 (25.1%) were depressed. Depression was not associated with time to first appropriate ICD therapy (unadjusted hazard ratio [HR] = 1.07, 95% confidence interval [CI] = 0.73-1.56). However, depression was associated with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3 months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients with an ICD. Patients with persistent depression during the first 3 months after implantation face the greatest risk of dying. Current evidence indicates that multifactorial interventions are likely to be the most successful in terms of reducing distress. Whether this translates into enhanced survival has yet to be determined.

  2. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Naehle, Claas P; Strach, Katharina; Thomas, Daniel; Meyer, Carsten; Linhart, Markus; Bitaraf, Sascha; Litt, Harold; Schwab, Jörg Otto; Schild, Hans; Sommer, Torsten

    2009-08-04

    Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).

  3. Electrical storm in patients with implantable cardioverter-defibrillators: can it be forecast?

    Science.gov (United States)

    Emkanjoo, Zahra; Alihasani, Narges; Alizadeh, Abolfath; Tayyebi, Mohammad; Bonakdar, Hamid; Barakpour, Hamid; Sadr-Ameli, Mohammad Ali

    2009-01-01

    The aim of this retrospective study was to determine the prevalence and predictors of electrical storm in 227 patients who had received implantable cardioverter-defibrillators (ICDs) and had been monitored for 31.7 +/- 15.6 months. Of these, 174 (77%) were men. The mean age was 55.8 +/- 15.5 years (range, 20-85 yr), and the mean left ventricular ejection fraction (LVEF) was 0.30 +/- 0.14. One hundred forty-six of the patients (64%) had underlying coronary artery disease. Cardioverter-defibrillators were implanted for secondary (80%) and primary (20%) prevention. Of the 227 patients, 117 (52%) experienced events that required ICD therapy. Thirty patients (mean age, 57.26 +/- 14.3 yr) had > or = 3 episodes requiring ICD therapy in a 24-hour period and were considered to have electrical storm. The mean number of events was 12.75 +/- 15 per patient. Arrhythmia-clustering occurred an average of 6.1 +/- 6.7 months after ICD implantation. Clinical variables with the most significant association with electrical storm were low LVEF (P = 0.04; hazard ratio of 0.261, and 95% confidence interval of 0.08-0.86) and higher use of class IA antiarrhythmic drugs (P = 0.018, hazard ratio of 3.84, and 95% confidence interval of 1.47-10.05). Amiodarone treatment and use of beta-blockers were not significant predictors when subjected to multivariate analysis. We conclude that electrical storm is most likely to occur in patients with lower LVEF and that the use of Class IA antiarrhythmic drugs is a risk factor.

  4. Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2017-01-01

    distress post-ICD implantation. The WEB-based distress management program for ICD patients (WEBCARE) was developed to mitigate anxiety and depression and enhance health-related quality of life in ICD patients. This study investigates the 6- and 12-months outcomes. METHOD: A total of 289 consecutive ICD...... care as usual. RESULTS: Current findings show no significant difference on anxiety, depression or quality of life between the WEBCARE and Usual Care group at 6- and 12-months postimplantation. CONCLUSIONS: In this clinical trial of a Web-based behavioral intervention for ICD patients, the Web...

  5. Attitudes of older adults with serious competing health risks toward their implantable cardioverter-defibrillators: a pilot study.

    Science.gov (United States)

    Green, Ariel R; Boyd, Cynthia M; Rickard, John; Gomon, Robert; Leff, Bruce

    2015-12-23

    In elderly heart failure patients, the survival benefit of implantable cardioverter-defibrillators (ICDs) may be attenuated due to competing health risks, and the risk of adverse outcomes magnified. Our objective was to examine older adults' attitudes towards ICD implantation in the context of competing health risks, exploring the determinants of ICD decision-making among a group of patients who had faced the decision in the past. Telephone survey with a qualitative component. Patients were age ≥70 with single- or dual-chamber ICDs from a single academic cardiac device clinic. Health status was assessed with the Vulnerable Elders Survey (VES-13). Responses to open-ended questions were transcribed verbatim; an "editing analysis" approach was used to extract themes. Forty-four ICD recipients participated (mean age 77.5 years). Nineteen participants (43%) had VES-13 scores ≥3, indicating a 50% likelihood of death or functional decline within 2 years. Twenty-one participants (48%) had received prior ICD shocks. Forty participants (91%) said they would "definitely" choose to get an ICD again in their current health. By and large, patients revealed a strong desire to extend life, expressed complete confidence in the lifesaving capabilities of their ICDs, and did not describe consideration of competing health risks. In this pilot telephone survey with a qualitative component, nearly all older adults with ICDs would still choose to get an ICD despite high short-term risk of death or health deterioration. These findings suggest the need to partner more effectively with patients and families to decide how best to use medical technologies, particularly for older adults with competing risks.

  6. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  7. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  8. Polymorphisms associated with ventricular tachyarrhythmias: rationale, design, and endpoints of the 'diagnostic data influence on disease management and relation of genomics to ventricular tachyarrhythmias in implantable cardioverter/defibrillator patients (DISCOVERY)' study

    DEFF Research Database (Denmark)

    Wieneke, Heinrich; Spencker, Sebastian; Svendsen, Jesper Hastrup

    2010-01-01

    Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphism...... pathways will be investigated. As it is a diagnostic study, DISCOVERY will also investigate the impact of long-term device diagnostic data on the management of patients suffering from chronic cardiac disease as well as medical decisions made regarding their treatment.......Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphisms...... modulate the risk for arrhythmias and sudden cardiac death, and identification of common variants could help to better identify patients at risk. The DISCOVERY study is an interventional, longitudinal, prospective, multi-centre diagnostic study that will enrol 1287 patients in approximately 80 European...

  9. Time dependence of risks and benefits in pediatric primary prevention implantable cardioverter-defibrillator therapy.

    Science.gov (United States)

    DeWitt, Elizabeth S; Triedman, John K; Cecchin, Frank; Mah, Doug Y; Abrams, Dominic J; Walsh, Edward P; Gauvreau, Kimberlee; Alexander, Mark E

    2014-12-01

    Implantable cardioverter defibrillators (ICDs) used to prevent sudden cardiac arrest in children not only provide appropriate therapy in 25% of patients but also result in a significant incidence of inappropriate shocks and other device complications. ICDs placed for secondary prevention have higher rates of appropriate therapy than those placed for primary prevention. Pediatric patients with primary prevention ICDs were studied to determine time-dependent incidence of appropriate use and adverse events. A total of 140 patients aged prevention were retrospectively identified. Demographics and times to first appropriate shock; adverse events (including inappropriate shock, lead failure, reintervention, and complication); generator replacement and follow-up were noted. During mean follow-up of 4 years, appropriate shock occurred in 19% patients and first adverse event (excluding death/transplant) occurred in 36%. Risk of death or transplant was ≈1% per year and was not related to receiving appropriate therapy. Conditional survival analysis showed rates of appropriate therapy and adverse events decrease soon after implantation, but adverse events are more frequent than appropriate therapy throughout follow-up. Primary prevention ICDs were associated with appropriate therapy in 19% and adverse event in 36% in this cohort. The incidence of both first appropriate therapy and device-related adverse events decreased during longer periods of follow-up after implantation. This suggests that indications for continued device therapy in pediatric primary prevention ICD patients might be reconsidered after a period of nonuse. © 2014 American Heart Association, Inc.

  10. How does an implantable cardioverter defibrillator (ICD) affect the lives of patients and their families?

    Science.gov (United States)

    Eckert, Marion; Jones, Tina

    2002-06-01

    This study aimed to identify the lived experience of patients with implantable cardioverter defibrillators (ICD) and their families. The methodology used was interpretative phenomenology. Unstructured interviews were conducted with three family members and three ICD recipients. Using a methodological approach outlined by van Manen, the participants transcribed texts were analysed looking for similar concepts and ideas that developed into themes that explicated the meaning of this phenomena. The themes that emerged were: dependence, which encompassed their perceptions about the life-saving device; the memory of their first defibrillation experience; lifestyle changes, which incorporated modification techniques; lack of control, which highlighted feelings such as fear, anxiety and powerlessness; mind game, which illustrated psychological challenges; and the issue of security, demonstrating how 'being there' and not 'being there' impacted on their everyday lives. The long-term outcomes of living with an ICD are important considerations for all health-care providers. This research highlights the everyday activities of recipients, the lifestyle changes they have made, the emotional significance of the device and the psychological coping strategies that the participants have adopted. The findings of this research will allow health-care professionals to be better prepared to provide education and support for ICD recipients and their families in regards to issues related to insertion of the device during the postinsertion recovery period and for long-term management after hospital discharge.

  11. Evidence of Cognitive Bias in Decision Making Around Implantable-Cardioverter Defibrillators: A Qualitative Framework Analysis.

    Science.gov (United States)

    Matlock, Daniel D; Jones, Jacqueline; Nowels, Carolyn T; Jenkins, Amy; Allen, Larry A; Kutner, Jean S

    2017-11-01

    Studies have demonstrated that patients with primary prevention implantable cardioverter-defibrillators (ICDs) often misunderstand the ICD. Advances in behavioral economics demonstrate that some misunderstandings may be due to cognitive biases. We aimed to explore the influence of cognitive bias on ICD decision making. We used a qualitative framework analysis including 9 cognitive biases: affect heuristic, affective forecasting, anchoring, availability, default effects, halo effects, optimism bias, framing effects, and state dependence. We interviewed 48 patients from 4 settings in Denver. The majority were male (n = 32). Overall median age was 61 years. We found frequent evidence for framing, default, and halo effects; some evidence of optimism bias, affect heuristic, state dependence, anchoring and availability bias; and little or no evidence of affective forecasting. Framing effects were apparent in overestimation of benefits and downplaying or omitting potential harms. We found evidence of cognitive bias in decision making for ICD implantation. The majority of these biases appeared to encourage ICD treatment. Published by Elsevier Inc.

  12. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.

    Science.gov (United States)

    Ryf, Salome; Wolber, Thomas; Duru, Firat; Luechinger, Roger

    2008-01-01

    Permanent magnets may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets have become widely available in recent years and are incorporated in various articles of daily life. We conducted an in-vitro study to evaluate the ability of NdFeB magnets for home and office use to cause interference with cardiac pacemakers and ICDs. The magnetic fields of ten NdFeB magnets of different size and shape were measured at increasing distances beginning from the surface until a field-strength (B-field) value of 0.5 mT was reached. Furthermore, for each magnet the distance was determined at which a sample pacemaker switched from magnet mode to normal mode. Depending on the size and remanence of individual magnets, a B-field value of 0.5 mT was found at distances ranging from 1.5 cm to 30 cm and a value of 1 mT at distances from 1 cm to 22 cm. The pacemaker behavior was influenced at distances from 1 cm to 24 cm. NdFeB magnets for home and office use may cause interference with cardiac pacemakers and ICDs at distances up to 24 centimeters. Patient education and product declarations should include information about the risk associated with these magnets.

  13. Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wolber, Thomas; Ryf, Salome; Binggeli, Christian; Holzmeister, Johannes; Brunckhorst, Corinna; Luechinger, Roger; Duru, Firat

    2007-01-01

    Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets, which are small in size but produce strong magnetic fields, have become widely available in recent years. Therefore, NdFeB magnets may be associated with an emerging risk of device interference. We conducted a clinical study to evaluate the potential of small NdFeB magnets to interfere with cardiac pacemakers and ICDs. The effect of four NdFeB magnets (two spherical magnets 8 and 10 mm in diameter, a necklace made of 45 spherical magnets, and a magnetic name tag) was tested in forty-one ambulatory patients with a pacemaker and 29 patients with an ICD. The maximum distance at which the magnetic switch of a device was influenced was observed. Magnetic interference was observed in all patients. The maximum distance resulting in device interference was 3 cm. No significant differences were found with respect to device manufacturer and device types. Small NdFeB magnets may cause interference with cardiac pacemakers and ICDs. Patients should be cautioned about the interference risk associated with NdFeB magnets during daily life.

  14. Cardiac e-learning: Development of a web-based implantable cardioverter defibrillator educational system.

    Science.gov (United States)

    Hickey, Kathleen T; Johnson, Mary P; Biviano, Angelo; Aboelela, Sally; Thomas, Tami; Bakken, Suzanne; Garan, Hasan; Zimmerman, John L; Whang, William

    2011-04-01

    The objective of this study was to design a Web-based implantable cardioverter defibrillator (ICD) module that would allow greater access to learning which could occur at an individual's convenience outside the fast-paced clinical environment. A Web-based ICD software educational program was developed to provide general knowledge of the function of the ICD and the interpretation of the stored electrocardiograms. This learning tool could be accessed at any time via the Columbia University Internet server, using a unique, password protected login. A series of basic and advanced ICD terms were presented using actual ICD screenshots and videos that simulated scenarios the practitioner would most commonly encounter in the fast-paced clinical setting. To determine the usefulness of the site and improve the module, practitioners were asked to complete a brief (less than 5 min) online survey at the end of the module. Twenty-six practitioners have logged into our Web site: 20 nurses/nurse practitioners, four cardiac fellows, and two other practitioners. The majority of respondents rated the program as easy to use and useful. The success of this module has led to it becoming part of the training for student nurse practitioners before a clinical electrophysiology rotation, and the module is accessed by our cardiac entry level fellows before a rotation in the intensive care unit or electrophysiology service. Remote electronic arrhythmia learning is a successful example of the melding of technology and education to enhance clinical learning.

  15. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2018-01-01

    disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...... psychometric attributes of validity and reliability in this implantable cardioverter defibrillator population. This study adds support for the HeartQoL as a core heart-specific health-related quality of life questionnaire in a broad group of patients with heart disease including implantable cardioverter...

  17. Do implantable cardioverter defibrillators improve survival in patients with severe left ventricular systolic dysfunction after coronary artery bypass graft surgery?

    Science.gov (United States)

    Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J

    2011-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines

  18. Is it safe to allow patients with implantable cardioverter-defibrillators to drive? Learnings from a single center experience.

    Science.gov (United States)

    Curnis, Antonio; Mascioli, Giosue; Bontempi, Luca; Cerini, Manuel; Bignotti, Tommaso; Bonetti, Gabriele; Dei Cas, Livio

    2008-12-01

    Implantable cardioverter-defibrillator (ICD) implant indications have widened in recent years after the publication of the Multicenter Automatic Defibrillator Implantation Trial 2 and the Sudden Cardiac Death in Heart Failure Trial. On the contrary, guidelines on resumption of driving after ICD implant were published almost 10 years ago when the ICD implant rate was much lower and candidates were generally older. The overall objective of our study was to evaluate whether patients implanted with ICDs have higher risk than the general driving population. The specific aim of the study was to verify the rate of car accidents in patients implanted with an ICD, both for primary and secondary indication, and compare this with the rate of accidents in the general population. The primary end point of the study was the annual car accident rate; the secondary end point was to determine if there were subgroups of patients with a higher risk of car accidents. All patients (612) followed up in our outpatient clinic were sent a questionnaire in which they were asked five questions regarding their driving habits before and after ICD implant and, specifically, whether they had been involved in a car accident after the implant. Two hundred eighty-six patients (47%) responded to the questionnaire. Seventy-one patients had never driven; two patients were forbidden to drive for professional reasons (one bus and one truck driver). Two hundred thirteen (74.5% of all responding) patients (201 men, mean age 62 +/- 11 years) continued to drive after ICD implant. During the follow-up (1430 +/- 920 days) 11 patients had been involved in car accidents and, importantly 10 out of 11 were innocent bystanders. Thus, in 996 patient-years, 11 events happened, yielding an annual event rate of 1.1% per patient-years (and only 0.1% in which the driver could had been responsible). Car accidents are infrequent in patients implanted with an ICD, and - in any case - not more frequent than in the general

  19. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  20. Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations; Strahlentherapie bei Patienten mit Herzschrittmachern oder implantierbaren Kardioverter-Defibrillatoren. Interdisziplinaere Sicherheitsempfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Dorenkamp, M.; Haverkmap, W.; Roser, M. [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Medizinische Klinik mit Schwerpunkt Kardiologie; Stromberger, C.; Wust, P. [Charite Universitaetsmedizin Berlin (Germany). Klinik fuer Radioonkologie und Strahlentherapie; Heymann, C. von [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Klinik fuer Anaesthesiologie mit Schwerpunkt operative Intensivmedizin

    2013-01-15

    Background: With increasing numbers of implanted pacemakers and implantable cardioverter defibrillators (ICD) and a rising incidence of malignant tumors, there is a growing probability of radiation-mediated device dysfunction. The only guidelines for the management of patients with cardiac pacemakers in the case of radiation therapy were published in 1994 and have not been updated since then. Based on the current evidence and modern device technology, the present paper aims to develop contemporary and interdisciplinary safety recommendations for the minimization of patient risk. Methods and results: A systematic literature research was carried out including the most relevant medical electronic databases. The search yielded 147 articles published between 1994 and 2012 of which 45 met the selection criteria and of these studies 34 presented primary data (9 in vitro and 25 in vivo studies). The impact of ionizing radiation varied significantly between implanted devices and ranged from no functional changes to complete loss of function. Important device dysfunctions included changes in sensing capability, altered pacing pulses or rate, changed or disabled tachyarrhythmia ICD therapies, early battery depletion and loss of telemetry. Modern pacemakers and ICDs are more sensitive to radiation than older models. Potentially life-threatening complications were observed after exposure of the pulse generator to comparatively low radiation doses (0.11 Gy). Conclusions: Practical recommendations for patient management and safety are presented that can be readily adopted by any institution carrying out radiation therapy. (orig.)

  1. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  2. Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy.

    Science.gov (United States)

    Brambatti, Michela; Mathew, Rebecca; Strang, Barbara; Dean, Joan; Goyal, Anuja; Hayward, Joseph E; Long, Laurene; DeMeis, Patty; Smoke, Marcia; Connolly, Stuart J; Morillo, Carlos A; Amit, Guy; Capucci, Alessandro; Healey, Jeff S

    2015-10-01

    Radiation therapy (RT) may pose acute and long-term risks for patients with cardiac implantable electronic devices (CIEDs), including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). However, the frequency of these problems has not been accurately defined. The purpose of this study was to determine the prevalence of CIEDs among patients requiring RT and report the common CIED-related problems when patients are managed according to a standard clinical care path. In a single tertiary-care center, we prospectively screened all patients requiring RT and identified patients with ICDs or PMs. We collected clinical data about their cancer, RT treatment plan, and CIED. Radiation dose to the device was estimated in all patients, and any device malfunction during RT was documented. Of the 34,706 consecutive patients receiving RT, 261 patients (0.8%, mean age 77.9 ± 9.4 years) had an implantable cardiac device: 54 (20.7%) ICDs and 207 (79.3%) PMs. The site of RT was head and neck (27.4%), chest (30.0%), and abdomen/pelvis (32.6%). Using our care path, 63.2% of patients required continuous cardiac monitoring, 14.6% required device reprogramming, 18.8% required magnet application during RT, and 3.4% required device repositioning to the contralateral side before RT. Four patients (1.5%) had inappropriate device function during RT: 3 experienced hemodynamically tolerated ventricular pacing at the maximum sensor rate, and 1 experienced a device power-on-reset. No patient died or suffered permanent device failure. Nearly 1% of patients receiving RT in this series has a PM or ICD. However, with a systematic policy of risk assessment and patient management, significant device-related complications are rare. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Sustaining cyborgs: sensing and tuning agencies of pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Oudshoorn, Nelly

    2015-02-01

    Recently there has been a renewed interest in cyborgs, and particularly in new and emerging fusions of humans and technologies related to the development of human enhancement technologies. These studies reflect a trend to follow new and emerging technologies. In this article, I argue that it is important to study 'older' and more familiar cyborgs as well. Studying 'the old' is important because it enables us to recognize hybrids' embodied experiences. This article addresses two of these older hybrids: pacemakers and implantable cardioverter defibrillators inserted in the bodies of people suffering from heart-rhythm disturbances. My concern with hybrid bodies is that internal devices seem to present a complex and neglected case if we wish to understand human agency. Their 'users' seem to be passive because they cannot exert any direct control over the working of their devices. Technologies inside bodies challenge a longstanding tradition of theorizing human-technology relations only in terms of technologies external to the body. Cyborg theory is problematic as well because most studies tend to conceptualize the cyborg merely as a discursive entity and silence the voices of people living as cyborgs. Inspired by feminist research that foregrounds the materiality of the lived and intimate relations between bodies and technologies, I argue that creating these intimate relations requires patients' active involvement in sustaining their hybrid bodies. Based on observations of these monitoring practices in a Dutch hospital and interviews with patients and technicians, the article shows that heart cyborgs are far from passive. On the contrary, their unique experience in sensing the entangled agencies of technologies and their own heart plays a crucial role in sustaining their hybrid bodies.

  4. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Scheepers, Egon; Springorum, Bob G.F.; Uiterwaal, Hans

    2005-01-01

    Purpose: Radiotherapy can influence the functioning of pacemakers and implantable cardioverter-defibrillators (ICDs). ICDs offer the same functionality as pacemakers, but are also able to deliver a high-voltage shock to the heart if needed. Guidelines for radiotherapy treatment of patients with an implanted rhythm device have been published in 1994 by The American Association of Physicists in Medicine, and are based only on experience with pacemakers. Data on the influence of radiotherapy on ICDs are limited. The objective of our study is to determine the influence of radiotherapy on the latest generation of ICDs. Methods and Materials: Eleven modern ICDs have been irradiated in our department. The irradiation was performed with a 6-MV photon beam. The given dose was fractionated up to a cumulative dose of 120 Gy. Two to 5 days passed between consecutive irradiations. Frequency, output, sensing, telemetry, and shock energy were monitored. Results: Sensing interference by ionizing radiation on all ICDs has been demonstrated. For four ICDs, this would have caused the inappropriate delivery of a shock because of interference. At the end of the irradiation sessions, all devices had reached their point of failure. Complete loss of function was observed for four ICDs at dose levels between 0.5 Gy and 1.5 Gy. Conclusions: The effect of radiation therapy on the newest generation of ICDs varies widely. If tachycardia monitoring and therapy are functional (programmed on) during irradiation, the ICD might inappropriately give antitachycardia therapy, often resulting in a shock. Although most ICDs did not fail below 80 Gy, some devices had already failed at doses below 1.5 Gy. Guidelines are formulated for the treatment of patients with an ICD

  5. Higher defibrillation threshold in methamphetamine cardiomyopathy patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Rakesh Malhotra

    2017-11-01

    Full Text Available Introduction: Identification of patients with an increased risk of high defibrillation thresholds (DFTs is important in planning implantable cardioverter-defibrillator (ICD procedures. Clinical observations have suggested that patients with methamphetamine cardiomyopathy (MACMP have significantly elevated defibrillation thresholds. We hypothesized that MACMP patients would have higher DFT thresholds than controls and would require procedural changes during ICD implantation to accommodate higher thresholds. Methods: We identified consecutive patients with MACMP undergoing ICD implantation at the academic center from 2003 to 2007. We then compared DFTs against age-and sex-matched controls. Results: The MACMP (n = 10 group showed significantly increased DFT thresholds (23.7 ± 6.7 J compared with age and sex-matched controls (14.5 ± 4.6 J, p < 0.005. Additionally, patients with MACMP had evidence of more severe congestive heart failure, with increased B-type natrieutic protein (BNP levels (1173 ± 784 vs 260 ± 349, p = 0.02 and decreased left ventricular ejection fraction (LVEF (17.8 ± 9.4 vs 35.9 ± 15.2, p = 0.02. MACMP patients required high output devices than controls (50% versus 0%, p = 0.03. Differences between groups remained significant despite adjusting for LVEF. Conclusions: Planning for ICD implantation should take into consideration a history of methamphetamine abuse, mandating DFT testing and empiric consideration of high output devices for such patients. Keywords: Methamphetamine cardiomyopathy, Implantable cardioverter-defibrillatior, Defibrillation threshold testing, B-type natriuretic peptide, Ejection fraction

  6. Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis.

    Science.gov (United States)

    Sunderland, Nicholas; Kaura, Amit; Murgatroyd, Francis; Dhillon, Para; Scott, Paul A

    2018-03-01

    Dual-coil implantable cardioverter defibrillator (ICD) leads have traditionally been used over single-coil leads due to concerns regarding high defibrillation thresholds (DFT) and consequent poor shock efficacy. However, accumulating evidence suggests that this position may be unfounded and that dual-coil leads may also be associated with higher complication rates during lead extraction. This meta-analysis collates data comparing dual- and single-coil ICD leads. Electronic databases were systematically searched for randomized controlled trials (RCT) and non-randomized studies comparing single-coil and dual-coil leads. The mean differences in DFT and summary estimates of the odds-ratio (OR) for first-shock efficacy and the hazard-ratio (HR) for all-cause mortality were calculated using random effects models. Eighteen studies including a total of 138,124 patients were identified. Dual-coil leads were associated with a lower DFT compared to single coil leads (mean difference -0.83J; 95% confidence interval [CI] -1.39--0.27; P = 0.004). There was no difference in the first-shock success rate with dual-coil compared to single-coil leads (OR 0.74; 95%CI 0.45-1.21; P=0.22). There was a significantly lower risk of all-cause mortality associated with single-coil leads (HR 0.91; 95%CI 0.86-0.95; P dual-coil leads. The mortality benefit with single-coil leads most likely represents patient selection bias. Given the increased risk and complexity of extracting dual-coil leads, centres should strongly consider single-coil ICD leads as the lead of choice for routine new left-sided ICD implants. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  8. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  9. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging.

    Science.gov (United States)

    Schoels, Wolfgang; Steinhaus, David; Johnson, W Ben; O'hara, Gilles; Schwab, Joerg O; Jenniskens, Inge; Degroot, Paul J; Tang, Feng; Helmling, Erhard

    2007-07-01

    Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. The purpose of this study was to determine the efficacy and safety of this new feature. In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.

  10. Complications and Mortality of Single Versus Dual Chamber Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Ataallah Bagherzadeh

    2006-04-01

    Full Text Available Background: The implantable cardioverter defibrillators (ICDs are increasingly being used as a treatment modality for life threatening tachyarrhythmia. The purpose of this study was to compare the frequency of complications and mortality between single-chamber and dual-chamber ICD implantation in Shahid Rajaie cardiovascular center. Methods and results: Between January 2000 and December 2004, 234 patients received ICD by a percutaneous transvenous approach and were followed for 33 ± 23 months. The cumulative incidence of complications was 9.4% over the follow-up period. There was no significant difference in overall complication rate between single chamber (VR and dual chamber (DR ICD groups in the follow-up period (P= 0.11. The risk of complications did not have any statistically significant difference in secondary versus primary prevention groups (P=0.06. The complications were not associated with the severity of left ventricular systolic dysfunction (P=0.16.The frequency of lead-related complications was higher in dual chamber ICDs in comparison with single chamber ICDs (P=0.02. There was no significant difference in mortality between different sex groups (P=0.37, different indications for ICD implantation (P=0.43 or between VR and DR ICD groups (P= 0.55. Predictors of mortality were NYHA class III or more (P65 years (P=0.011 and LVEF<30% (P<0.001. The mortality in patients with CAD and DCM were significantly higher than those with other structural heart diseases (P=0.001. Conclusions: Close monitoring of patients during the first 2 month after ICD implantation is recommended because the majority of complications occur early after the procedure.

  11. Digoxin Is Associated With Increased Shock Events and Electrical Storms in Patients With Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Mina, George S; Acharya, Madan; Shepherd, Taylor; Gobrial, George; Tekeste, Michael; Watti, Hussam; Bhandari, Ruchi; Saini, Aditya; Reddy, Pratap; Dominic, Paari

    2018-03-01

    Recently, digoxin use has been found to associate with higher mortality. Yet, potential mechanisms by which digoxin use increases mortality remain unclear. Increased arrhythmogenicity from digoxin use is one possibility. Thus, we aimed to evaluate the relation between digoxin and shock events in patients with implantable cardioverter defibrillators (ICDs). We performed a retrospective chart review of all patients with ICDs and at least 1 device interrogation at our institution between January 1, 2012, and January 1, 2015. We aimed to cover 1 year of interrogation period. Patients with heart failure, atrial fibrillation, or both were included in the analysis. Patients were divided into 2 groups based on digoxin use, defined as use of digoxin for any period of time during ICD interrogation period. Incidence of ICD shock events and electrical storms and hospitalizations were compared between the 2 groups. The study included 202 patients. Of those, 55 patients were on digoxin and 147 were not on digoxin. Patients on digoxin were more likely to receive ICD shocks (odds ratio [OR] = 2.5, 95% confidence interval [95% CI] = 1.01-6.18, P = .04) and have increased risk of electrical storms ( P = .02). Moreover, total hospitalizations were higher in digoxin users ( P = .02). Multivariate logistic regression analysis also showed that digoxin use was an independent predictor of shock events (OR = 4.07, 95% CI = 1.43-11.58, P = .009). Digoxin is associated with increased shock events and electrical storms in patients with ICDs; however, large randomized controlled studies are needed to confirm our findings.

  12. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  13. Adherence to an Aerobic Exercise Intervention after an Implantable Cardioverter Defibrillator (ICD).

    Science.gov (United States)

    Dougherty, Cynthia M; Luttrell, Matilda N; Burr, Robert L; Kim, Misun; Haskell, William L

    2016-02-01

    Exercise adherence is an important element in achieving important exercise outcomes. The purpose of this study was to describe adherence in a home-based aerobic exercise program following an implantable cardioverter defibrillator (ICD), determine effects of adherence on peakVO2 , and outline reasons for nonadherence. A single-blind randomized control trial of home walking compared to usual care in 160 patients with an ICD for primary or secondary prevention was conducted. This report is on adherence in the exercise arm (N = 84). Home walking exercise consisted of 8 weeks of aerobic conditioning (60 minutes/day, 5 days/week) followed by 16 weeks of aerobic maintenance (150 minutes/week, 30 minutes/session) at 60-80% of heart rate reserve. Adherence was tracked using Polar heart rate (HR) monitors, pedometers, home exercise logs, and telephone follow-up. Adherence was defined as performing at least 80% of prescribed exercise. For aerobic conditioning, there was a mean frequency of 3.81 walks/week, duration of 1,873 minutes walked, and 17.5% of exercise was in the target HR (THR) zone. For aerobic maintenance, there was a mean frequency of 2.4 walks/week, duration of 1,872 minutes/walked, and 8.7% of exercise was in the THR zone. Those who were 80% adherent achieved a 3.4 mL/kg/min (P = 0.03) improvement in peakVO2 over those who were exercise ranged from scheduling issues to viral illness and fatigue. Adherence to aerobic exercise frequency and duration was high with few dropouts, resulting in higher peakVO2 . Exercise monitoring equipment encouraged adherence and conferred a sense of safety to exercise. ©2015 Wiley Periodicals, Inc.

  14. Prognosis after implantation of cardioverter-defibrillators in Korean patients with Brugada syndrome.

    Science.gov (United States)

    Son, Myoung Kyun; Byeon, Kyeongmin; Park, Seung-Jung; Kim, June Soo; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho; Park, Sang Weon; Kim, Young-Hoon; Park, Hyung Wook; Cho, Jeong Gwan; On, Young Keun

    2014-01-01

    Our study aims to analyze prognosis after implantable cardioverter-defibrillator (ICD) implantation in Korean patients with Brugada syndrome (BrS). This was a retrospective study of BrS patients implanted with an ICD at one of four centers in Korea between January 1998 and April 2012. Sixty-nine patients (68 males, 1 female) were implanted with an ICD based on aborted cardiac arrest (n=38, 55%), history of syncope (n=17, 25%), or induced ventricular tachyarrhythmia on electrophysiologic study in asymptomatic patients (n=14, 20%). A family history of sudden cardiac death and a spontaneous type 1 electrocardiography (ECG) were noted in 13 patients (19%) and 44 patients (64%), respectively. During a mean follow-up of 59±46 months, 4.6±5.5 appropriate shocks were delivered in 19 patients (28%). Fourteen patients (20%) experienced 5.2±8.0 inappropriate shocks caused by supraventricular arrhythmia, lead failure, or abnormal sensing. Six patients were admitted for cardiac causes during follow-up, but no cardiac deaths occurred. An episode of aborted cardiac arrest was a significant predictor of appropriate shock, and the composite of cardiac events in the Cox proportional hazard model [hazard ratio (95% confidence interval) was 11.34 (1.31-97.94) and 4.78 (1.41-16.22), respectively]. However, a spontaneous type 1 ECG was not a predictor of cardiac events. Appropriate shock (28%) and inappropriate shock (20%) were noted during a mean follow-up of 59±46 months in Korean BrS patients implanted with an ICD. An episode of aborted cardiac arrest was the most powerful predictor of cardiac events.

  15. Infrequent physician use of implantable cardioverter-defibrillators risks patient safety.

    Science.gov (United States)

    Lyman, Stephen; Sedrakyan, Art; Do, Huong; Razzano, Renee; Mushlin, Alvin I

    2011-10-01

    Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. This cohort (N = 38,992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR = 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.

  16. Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators.

    Science.gov (United States)

    Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence

    2016-05-01

    Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks.

    Science.gov (United States)

    Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R

    2015-03-01

    Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. A patient with severely reduced LV function and electrical storm saved by wearable cardioverter-defibrillator: a case report.

    Science.gov (United States)

    Strauss, Margit; Kouraki, Kleopatra; Skarlos, Alexandros; Zahn, Ralf; Kleemann, Thomas

    2013-06-01

    The wearable cardioverter-defibrillator (WCD) is indicated in patients who are considered to be at temporarily high risk for sudden cardiac death (SCD), when an implantable defibrillator is not yet clearly indicated. We report the case of a 41-year-old patient with a newly diagnosed severely reduced left ventricular (LV) function for suspected myocarditis and repeated nonsustained ventricular tachycardia (VT). This patient was supplied with a WCD who came back to the hospital 4 weeks after discharge with an electrical storm and adequate discharge of the WCD. After application of amiodarone, no further arrhythmias were detected during intrahospital course. For further risk stratification, we performed a magnetic field imaging (MFI), that was reported to be useful in risk assessment of SCD in patients with ischemic cardiomyopathy. This measurement showed a normal result, but we decided to give an implantable cardioverter-defibrillator (ICD) to the patient. During a follow-up of 1 year, no further arrhythmias occurred. With this case, we report the efficacy of a WCD, which is a novel tool in patients at temporarily high risk of SCD and we report a novel method of risk stratification in patients with a high risk of SCD.

  19. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  20. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Kupper, N.; Jordaens, L.; Pedersen, S.S.; Theuns, D.A.M.J.

    2013-01-01

    Aims Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health

  1. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  2. Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Brigadeau, François; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Duhamel, Alain; Mizon-Gérard, Frédérique; Lacroix, Dominique; Kacet, Salem

    2006-03-01

    Insufficient data exists regarding predictors of electrical storms (ES) and clinical outcome in patients treated with an implantable cardioverter defibrillator (ICD). The purpose of this study was to delineate a subgroup of patients likely to experience ES and to determine the impact of ES on mortality in ICD recipients. Baseline characteristics of 307 ICD-treated patients were retrospectively analysed. ES was defined as two or more ventricular tachyarrhythmias within 24 h leading to an immediate electrical therapy (antitachycardia pacing and/or shock), separated by a period of sinus rhythm. Clinical characteristics and survival of 123 patients experiencing a total of 294 episodes of ES (median 2 ES/patient, range 1-9), were compared with those of 184 ES-free patients during a median follow-up of 826 days (inter-quartile 1141 days). Median actuarial duration for the first ES occurrence after ICD implant was 1417 days [95% confidence interval (CI) 1061-2363] with a median follow-up of 816 days (7-4642 days) in ES-free patients. Univariate analysis identified older age, depressed left ventricular ejection fraction (LVEF), ventricular tachycardia (VT) as index arrhythmia, chronic renal failure and absence of lipid-lowering drugs as variables significantly associated with an increased risk of ES. Multivariable Cox analysis confirmed an independent predictive value for chronic renal failure [hazard ratio (HR) 1.54, 95% CI 0.95-2.51, P=0.052], VT (HR 2.20, 95% CI 1.44-3.37, P=0.0003), and LVEF (HR 0.98, 95% CI 0.97-0.99, P=0.027). In contrast, diabetics (HR 0.49, 95% CI 0.27-0.90, P=0.022) were less affected by ES. There was no difference in survival between both groups. ES is frequent but does not increase mortality in ICD's recipients. Patients with severe systolic dysfunction, chronic renal failure and VT as initial arrhythmia are likely to experience ES. Diabetics are less affected by ES.

  3. Comparison of clinical benefits and outcome in patients with programmable and nonprogrammable implantable cardioverter defibrillators.

    Science.gov (United States)

    Mehta, D; Saksena, S; Krol, R B; Makhija, V

    1992-09-01

    Technological advances in implantable cardioverter defibrillators (ICDs) have provided a variety of programmable parameters and antitachycardia therapies whose utility and impact on clinical outcome is presently unknown. ICDs have capabilities for cardioversion defibrillation alone (first generation ICDs), or in conjunction with demand ventricular pacing (second generation ICDs), or with demand pacing and antitachycardia pacing (third generation ICDs). We examined the pattern of antitachycardia therapy use and long-term survival in 110 patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Group I included 62 patients with nonprogrammable first generation ICDs that delivered committed shock therapy after ventricular tachyarrhythmia detection based on electrogram rate and/or morphology was satisfied. Group II included 48 patients with multiprogrammable ICDs (including second and third generation ICDs) that had programmable tachyarrhythmia detection based on rate and tachycardia confirmation prior to delivery of electrical treatment with either programmable shocks and/or, as in the third generation ICDs, antitachycardia pacing. Incidence and patterns of antitachycardia therapy use and long-term survival were compared in the two groups. The incidence of appropriate shocks in patients who completed 1 year of follow-up was significantly greater in group I (30 of 43 patients = 70% vs 11 of 26 patients = 42%; P less than 0.05). In the total follow-up period, a significantly larger proportion of group I patients as compared to group II patients used the shock therapies (46 of 62 patients = 74% vs 25 of 48 patients = 52%; P less than 0.01), with the majority doing so within the first year of implantation (96% and 92%, respectively). Although the frequency of antitachycardia therapy activation was similar, the number of shocks delivered per patient was lower in group II, particularly in the initial 3 months of follow-up (P = 0.06). No clinical

  4. A clinical example of extreme dose exposure for an implanted cardioverter-defibrillator. Beyond the DEGRO guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hristova, Yoana; Koehn, Janett; Preuss, Stefanie [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); Roedel, Claus; Balermpas, Panagiotis [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); German Cancer Consortium (DKTK), Frankfurt am Main (Germany)

    2017-09-15

    Considering that the number of malignant diseases in patients over 65 years of age is increasing, it often occurs that patients who carry a cardiac implanted electronic device must undergo radiotherapy. Ionizing radiation can disturb the function of the implantable cardioverter-defibrillator (ICD). As a result of this, an update of the DEGRO/DKG guidelines for radiotherapy of this patient group has been published. We report the case of a patient with an ICD and T-lymphoblastic lymphoma with cardiac involvement, who received i.a. a total body irradiation with 8 Gy followed by a consolidating radiotherapy of the pericardium with 14 Gy as well as additional radiotherapy courses after consecutive recurrences. For the purposes of the treatment, the antitachyarrhythmia (ATA) therapy was deactivated and temporarily replaced through a life vest. According to the current DEGRO guidelines for irradiation of patients with cardiac implanted electronic devices, a categorization of the patient in the ''high-risk'' group was made. Furthermore, regular telemetric checks of the ICD device were performed before and after treatment. Despite unavailable declaration of the manufacturer regarding the cumulative tolerable dose and DEGRO recommendation for a cumulative dose <2 Gy, the aftercare was unproblematic and normal values were assessed for all relevant ICD parameters, despite a cumulative dose >10 Gy in the device. This case shows that if the cardiac implanted electronic devices are not directly irradiated und the energy used is reduced to 6 MV, irradiation-induced damage is less likely and can possibly be prevented. (orig.) [German] Vor dem Hintergrund der steigenden Zahl von Krebserkrankungen bei Patienten ueber 65 Jahren kommt es haeufig vor, dass sich Patienten mit einem kardialen implantierten elektronischen Geraet einer Strahlentherapie unterziehen muessen. Ionisierende Strahlung kann die Funktion des implantierbaren Kardioverter-Defibrillators (ICD

  5. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...... ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. RESULTS: Of 44,423 BC patients, 179...

  6. Implantable Cardioverter-Defibrillator Therapy in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy: Predictors of Appropriate Therapy, Outcomes, and Complications.

    Science.gov (United States)

    Orgeron, Gabriela M; James, Cynthia A; Te Riele, Anneline; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Kamel, Ihab R; Zimmerman, Stephan L; Judge, Daniel P; Crosson, Jane; Tandri, Harikrishna; Calkins, Hugh

    2017-06-06

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy is characterized by ventricular arrhythmias and sudden cardiac death. Once the diagnosis is established, risk stratification to determine whether implantable cardioverter-defibrillator (ICD) placement is warranted is critical. The cohort included 312 patients (163 men, age at presentation 33.6±13.9 years) with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy who received an ICD. Over 8.8±7.33 years, 186 participants (60%) had appropriate ICD therapy and 58 (19%) had an intervention for ventricular fibrillation/flutter. Ventricular tachycardia at presentation (hazard ratio [HR]: 1.86; 95% confidence interval [CI], 1.38-2.49; P right ventricular dysplasia/cardiomyopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Optimism as predictor of patient-reported outcomes in patients with an implantable cardioverter defibrillator (data from the WEBCARE study)

    DEFF Research Database (Denmark)

    Habibović, M; Broers, E; Heumen, D

    2018-01-01

    OBJECTIVE: The implantable cardioverter defibrillator (ICD) is the treatment of choice for prevention of sudden cardiac death. However, a subgroup of ICD patients experiences psychological adjustment problems post implant. To date, positive psychological constructs (e.g. optimism) have been...... understudied in this population. Hence, we examined the association between optimism and anxiety, depression, and health status at 12-months post implant. METHODS: Patients (N=171) enrolled in the WEB-based distress management study for ICD patients were included in the analyses. Optimism and pessimism (LOT......), and Type D personality (DS14) were administered at baseline, while anxiety (GAD-7), depression (PHQ-9), and health status (SF-12) were assessed at 12-months. RESULTS: The mean age was 59.6±10.06 with 81% being male. After controlling for demographic, personality, and clinical variables, baseline optimism...

  8. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz

    International Nuclear Information System (INIS)

    Katrib, J; Nadi, M; Kourtiche, D; Schmitt, P; Roth, P; Magne, I; Souques, M

    2013-01-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs. (paper)

  9. Thoracoscopic Left Cardiac Sympathetic Denervation for a Patient with Catecholaminergic Polymorphic Ventricular Tachycardia and Recurrent Implantable Cardioverter-Defibrillator Shocks

    Directory of Open Access Journals (Sweden)

    Woo-Sik Yu

    2015-06-01

    Full Text Available A patient presented with loss of consciousness and conversion. During an exercise test, catecholaminergic polymorphic ventricular tachycardia (CPVT resulted in cardiac arrest. He started taking medication (a beta-blocker and flecainide and an implantable cardioverter defibrillator (ICD was inserted, but the ventricular tachycardia did not resolve. Left cardiac sympathetic denervation (LCSD was then performed under general anesthesia, and the patient was discharged on the second postoperative day without complications. One month after the operation, no shock had been administered by the ICD, and an exercise stress test did not induce ventricular tachycardia. Although beta- blockers are the gold standard of therapy in patients with CPVT, thoracoscopic LCSD is safe and can be an effective alternative treatment option for patients with intractable CPVT.

  10. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator (The DEFIB-WOMEN study)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Mathiasen, Kim; Christensen, Karl Bang

    2016-01-01

    OBJECTIVE: To assess the psychometric properties of the Patient Health Questionnaire (PHQ-9), a measure of depressive symptoms, in a large Danish national cohort of patients with heart disease, implanted with an implantable cardioverter defibrillator (ICD), using item response theory. METHODS: A ...... of nine items for the partial credit model and five of nine items for the generalized partial credit model, indicating that respondents have difficulty discriminating between response options. When collapsing response options 2 and 3, the rescored PHQ-9 had a better fit to both models....... Three items did not fit the partial credit model, but the generalized partial credit model could be fitted to the full item set. CONCLUSION: The unidimensionality and reliability of the Danish version of the PHQ-9 were confirmed. However, the associated consequences of the number of response options (3...

  11. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    DEFF Research Database (Denmark)

    Habibovic, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2014-01-01

    AIMS: Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed 10...... with a two-factor model involving both negative (α = 0.84) and positive expectations (α = 0.77) with a score range of 0-20 for each factor. Negative treatment expectations were associated with higher levels of anxiety (β = 0.443; P ...-item EXPECtations Towards ICD therapy (EXPECT-ICD) in relation to anxiety, depression, and ICD related concerns 3 months post-implant.METHODS AND RESULTS: Consecutive implanted ICD patients were included as part of the WEB-based distress management programme for ICD patients (WEBCARE) trial from six...

  12. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  13. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    Science.gov (United States)

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  14. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2017-01-01

    Background Patient-reported health-related quality of life is increasingly used as an outcome measure in clinical trials and as a performance measure to evaluate quality of care. The objective of this study was to assess the psychometric properties of the Danish HeartQoL questionnaire, a core heart...... disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...

  15. Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.

    Science.gov (United States)

    Tan, Vern Hsen; Wilton, Stephen B; Kuriachan, Vikas; Sumner, Glen L; Exner, Derek V

    2014-02-01

    Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduction programming with the risks of death from any cause, implantable cardioverter defibrillator shocks, and syncope. MEDLINE, EMBASE, and clinicaltrials.gov databases were searched to identify relevant studies. Those that followed patients for ≥6 months and reported mortality were included. Six met the inclusion criteria; 4 randomized (Comparison of Empiric to Physician-Tailored Programming of ICDs [EMPIRIC], Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy [MADIT-RIT], Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III [ADVANCE III], and Programming Implantable Cardioverter-Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock [PROVIDE]) and 2 prospective studies (Role of Long Detection Window Programming in Patients With Left Ventricular Dysfunction, Non-ischemic Etiology in Primary Prevention Treated with a Biventricular ICD [RELEVANT] and Primary Prevention Parameters Evaluation [PREPARE]). These 6 studies included 7687 (3598 conventional and 4089 therapy reduction programming) patients. Most (77%) participants were men, had a history of ischemic heart disease (56%), and were prescribed β-blockers (84%). Therapy reduction programming was associated with a 30% relative reduction in mortality (95% confidence interval, 16%-41%; Pprogramming (P=0.5). Therapy reduction programming results in a large, significant, and consistent reduction in mortality, with no apparent increase in the risk of syncope.

  16. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  17. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    OpenAIRE

    Alzand, B. S. N.; Timmermans, C. C. M. M.; Wellens, H. J. J.; Dennert, R.; Philippens, S. A. M.; Portegijs, P. J. M.; Rodriguez, LM.

    2011-01-01

    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial...

  18. Wearable cardioverter defibrillators for the prevention of sudden cardiac arrest: a health technology assessment and patient focus group study

    Directory of Open Access Journals (Sweden)

    Ettinger S

    2017-11-01

    Full Text Available Sabine Ettinger,1 Michal Stanak,1 Piotr Szymański,2 Claudia Wild,1 Romana Tandara Haček,3 Darija Erčević,3 Renata Grenković,3 Mirjana Huić3 1Ludwig Boltzmann Institute for Health Technology Assessment, Vienna, Austria; 2Institute of Cardiology, Warsaw, Poland; 3Department for Development, Research and Health Technology Assessment, Agency for Quality and Accreditation in Health Care and Social Welfare, Zagreb, Croatia Aim: To summarize the evidence on clinical effectiveness and safety of wearable cardioverter defibrillator (WCD therapy for primary and secondary prevention of sudden cardiac arrest in patients at risk. Methods: We performed a systematic literature search in databases including MEDLINE via OVID, Embase, the Cochrane Library, and CRD (DARE, NHS-EED, HTA. The evidence obtained was summarized according to GRADE methodology. A health technology assessment (HTA was conducted using the HTA Core Model® for rapid relative effectiveness assessment. Primary outcomes for the clinical effectiveness domain were all-cause and disease-specific mortality. Outcomes for the safety domain were adverse events (AEs and serious adverse events (SAEs. A focus group with cardiac disease patients was conducted to evaluate ethical, organizational, patient, social, and legal aspects of the WCD use. Results: No randomized- or non-randomized controlled trials were identified. Non-comparative studies (n=5 reported AEs including skin rash/itching (6%, false alarms (14%, and palpitations/light-headedness/fainting (9% and discontinuation due to comfort/lifestyle issues (16–22%, and SAEs including inappropriate shocks (0–2%, unsuccessful shocks (0–0.7%, and death (0–0.3%. The focus group results reported that experiencing a sense of security is crucial to patients and that the WCD is not considered an option for weeks or even months due to expected restrictions in living a “normal” life. Conclusion: The WCD appears to be relatively safe for short

  19. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  20. Depression, psychological distress, and quality of life in patients with cardioverter defibrillator with or without cardiac resynchronization therapy.

    Science.gov (United States)

    Knackstedt, Christian; Arndt, Marlies; Mischke, Karl; Marx, Nikolaus; Nieman, Fred; Kunert, Hanns Jürgen; Schauerte, Patrick; Norra, Christine

    2014-05-01

    Congestive heart failure is frequent and leads to reduced exercise capacity, reduced quality of life (QoL), and depression in many patients. Cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD) offer therapeutic options and may have an impact on QoL and depression. This study was performed to evaluate physical and mental health in patients undergoing ICD or combined CRT/ICD-implantation (CRT-D). Echocardiography, spiroergometry, and psychometric questionnaires [Beck Depression Inventory, General World Health Organization Five Well-being Index (WHO-5), Brief Symptom Inventory and 36-item Short Form (SF-36)] were obtained in 39 patients (ICD: 17, CRT-D: 22) at baseline and 6-month follow-up (FU) after device implantation. CRT-D patients had a higher NYHA class and broader left bundle branch block than ICD patients at baseline. At FU, ejection fraction (EF), peak oxygen uptake, and NYHA class improved significantly in CRT-D patients but remained unchanged in ICD patients. Patients with CRT-D implantation showed higher levels of depressive symptoms, psychological distress, and impairment in QoL at baseline and FU compared to ICD patients. These impairments remained mostly unchanged in all patients after 6 months. Overall, these findings imply that there is a need for careful assessment and treatment of psychological distress and depression in ICD and CRT-D patients in the course of device implantation as psychological burden seems to persist irrespective of physical improvement.

  1. Sex is associated with differences in individual trajectories of change in social health after implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lauck, Sandra B; Sawatzky, Richard; Johnson, Joy L; Humphries, Karin; Bennett, Matthew T; Chakrabarti, Santabhanu; Kerr, Charles R; Tung, Stanley; Yeung-Lai-Wah, John A; Ratner, Pamela A

    2015-03-01

    Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: Pchange in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change. © 2015 American Heart Association, Inc.

  2. Classic conditioning and dysfunctional cognitions in patients with panic disorder and agoraphobia treated with an implantable cardioverter/defibrillator.

    Science.gov (United States)

    Godemann, F; Ahrens, B; Behrens, S; Berthold, R; Gandor, C; Lampe, F; Linden, M

    2001-01-01

    A model for the development of anxiety disorders (panic disorder with or without agoraphobia) is needed. Patients with an implantable cardioverter/defibrillator (ICD) are exposed to repeated electric shocks. If the theory of anxiety development by aversive classic conditioning processes is valid, these repeated shocks should lead to an increased risk of anxiety disorders. To study this hypothesis, we retrospectively studied 72 patients after implantation of an automatic ICD. Patients were assessed with the semistructured Diagnostic Interview of Psychiatric Disease 1 to 6 years after implantation of an automatic ICD. Panic disorder and/or agoraphobia was diagnosed in patients who fulfilled all DSM-III-R criteria for those conditions. Anxiety disorder developed in 15.9% of patients after ICD implantation. This was significantly related to the frequency of repeated defibrillation (shocks) to stop malignant ventricular arrhythmias. Dysfunctional cognitions are an additional vulnerability factor. The data support both the conditioning hypothesis and the cognitive model of anxiety development. These findings suggest that ICD patients are an appropriate risk population for a prospective study of the development of anxiety disorders.

  3. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  4. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO 2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM 10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO 2 , PM 10 , NO 2 , and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

    Directory of Open Access Journals (Sweden)

    Pasque Michael K

    2007-01-01

    Full Text Available Abstract Objective Patients with severe left ventricular (LV dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF ≤25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+ in the post -operative period was compared to those without ICD (ICD-. Survival was evaluated by the Kaplan-Meier method. Results Of the entire group, 35 (11.5% patients received an ICD with a median of 2 (+/-2 years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT. There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p Conclusion Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.

  6. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    Science.gov (United States)

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  7. Use of implantable cardioverter defibrillators after out-of-hospital cardiac arrest: a prospective follow-up study

    Science.gov (United States)

    Parkash, Ratika; Tang, Anthony; Wells, George; Blackburn, Josée; Stiell, Ian; Simpson, Christopher; Dorian, Paul; Yee, Raymond; Cameron, Doug; Connolly, Stuart; Birnie, David; Nichol, Graham

    2004-01-01

    Background Survivors of out-of-hospital cardiac arrest are at high risk of recurrent arrests, many of which could be prevented with implantable cardioverter defibrillators (ICDs). We sought to determine the ICD insertion rate among survivors of out-of-hospital cardiac arrest and to determine factors associated with ICD implantation. Methods The Ontario Prehospital Advanced Life Support (OPALS) study is a prospective, multiphase, before–after study assessing the effectiveness of prehospital interventions for people experiencing cardiac arrest, trauma or respiratory arrest in 19 Ontario communities. We linked OPALS data describing survivors of cardiac arrest with data from all defibrillator implantation centres in Ontario. Results From January 1997 to April 2002, 454 patients in the OPALS study survived to hospital discharge after experiencing an out-of-hospital cardiac arrest. The mean age was 65 (standard deviation 14) years, 122 (26.9%) were women, 398 (87.7%) had a witnessed arrest, 372 (81.9%) had an initial rhythm of ventricular tachycardia or ventricular fibrillation (VT/VF), and 76 (16.7%) had asystole or another arrhythmia. The median cerebral performance category at discharge (range 1–5, 1 = normal) was 1. Only 58 (12.8%) of the 454 patients received an ICD. Patients with an initial rhythm of VT/VF were more likely than those with an initial rhythm of asystole or another rhythm to undergo device insertion (adjusted odds ratio [OR] 9.63, 95% confidence interval [CI] 1.31–71.50). Similarly, patients with a normal cerebral performance score were more likely than those with abnormal scores to undergo ICD insertion (adjusted OR 12.52, 95% CI 1.74–92.12). Interpretation A minority of patients who survived cardiac arrest underwent ICD insertion. It is unclear whether this low usage rate reflects referral bias, selection bias by electrophysiologists, supply constraint or patient preference. PMID:15505267

  8. Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system.

    Science.gov (United States)

    Jilek, Clemens; Tzeis, Stylianos; Reents, Tilko; Estner, Heidi-Luise; Fichtner, Stephanie; Ammar, Sonia; Wu, Jinjin; Hessling, Gabriele; Deisenhofer, Isabel; Kolb, Christof

    2010-10-01

    Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices. A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St. Louis, MO, USA) at the maximal magnetic field strength of 0.1 Tesla and evaluated in vitro with respect to changes in parameter settings of the device, changes of the battery status/detection of elective replacement indication, or alterations of data stored in the device. A total of 115 out of 121 (95%) devices were free of changes in parameter settings, battery status, and internally stored data after repeated exposition to the electromagnetic field of the remote magnetic navigation system. Interference with the magnetic navigation field was observed in 6 pacemakers, resulting in reprogramming to a power-on-reset mode with or without detection of the elective replacement indication in 5 devices and abnormal variance of battery status in one device. All pacemakers could be reprogrammed to the initial modes and the battery status proved to be normal some minutes after the pacemakers had been removed from the magnetic field. Interference of a remote magnetic navigation system (at maximal field strength) with pacemakers and ICDs not connected to leads with antitachycardic detection and therapies turned off is rare. Occurring functional abnormalities could be reprogrammed in our sample. An in vitro study will give information about interference of devices connected to leads. © 2010 Wiley Periodicals, Inc.

  9. Impact of Moderate to Severe Renal Impairment on Mortality and Appropriate Shocks in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Venkata M. Alla

    2010-01-01

    Full Text Available Background. Due to underrepresentation of patients with chronic kidney disease (CKD in large Implantable-Cardioverter Defibrillator (ICD clinical trials, the impact of ICD remains uncertain in this population. Methods. Consecutive patients who received ICD at Creighton university medical center between years 2000–2004 were included in a retrospective cohort after excluding those on maintenance dialysis. Based on baseline Glomerular filtration rate (GFR, patients were classified as severe CKD: GFR < 30 mL/min; moderate CKD: GFR: 30–59 mL/min; and mild or no CKD: GFR ≥ 60 mL/min. The impact of GFR on appropriate shocks and survival was assessed using Kaplan-Meier method and Generalized Linear Models (GLM with log-link function. Results. There were 509 patients with a mean follow-up of 3.0 + 1.3 years. Mortality risk was inversely proportional to the estimated GFR: 2 fold higher risk with GFR between 30–59 mL/min and 5 fold higher risk with GFR < 30 mL/min. One hundred and seventy-seven patients received appropriate shock(s; appropriate shock-free survival was lower in patients with severe CKD (GFR < 30 compared to mild or no CKD group (2.8 versus 4.2 yrs. Conclusion. Even moderate renal dysfunction increases all cause mortality in CKD patients with ICD. Severe but not moderate CKD is an independent predictor for time to first appropriate shock.

  10. Interaction between shock coils increased the incidence of inappropriate therapies and lead failure in implantable cardioverter defibrillator.

    Science.gov (United States)

    El Garhy, Mohammad; Ohlow, Marc-Alexander; Lauer, Bernward

    Shock coil interaction in patients with multiple implantable cardioverter defibrillator (ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil interaction and its clinical relevance. All ICD patients (646 patients) who came to follow up control in our ICD ambulance between January 1, 2011, and December 31, 2011 in the department of cardiology in Bad Berka hospital were retrospectively evaluated in this study. All baseline demographic, clinical, and procedural characteristics and postoperative chest x ray in postero-anterior and lateral view as well as clinical and ICD follow up data were evaluated. Among 646 patients 42 had multiple ICD leads (6.5%) of whom 36 patients (5.5% of total cohort patients and 85.7% of patients with multiple ICD leads) had shock coil interaction and presented the study group (Group I). The control group (Group II) consisted of 610 patients without coil-coil interaction including patients with single shock lead (604 patients) or patients with multiple leads but without interaction between shock coils (6 patients). Inappropriate anti-tachycardia therapies and RV lead revisions were more frequent in patients with interaction between shock coils (Group I vs Group II: 27.7% and 5.7%; p = 0.049 and 30.6% vs 6.4; p = 0.0001, respectively). Interaction between shock coils may be one of possible causes of lead failure and resulted in inappropriate therapies and subsequent lead revision. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  11. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.

    Science.gov (United States)

    Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco

    2018-04-01

    During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.

  12. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  13. Decision-Making of Patients With Implantable Cardioverter-Defibrillators at End of Life: Family Members' Experiences.

    Science.gov (United States)

    Lee, Mei Ching; Sulmasy, Daniel P; Gallo, Joseph; Kub, Joan; Hughes, Mark T; Russell, Stuart; Kellogg, Anela; Owens, Sharon G; Terry, Peter; Nolan, Marie T

    2017-07-01

    Many patients with advanced heart failure (HF) experience the life-extending benefits of implantable cardioverter-defibrillators (ICD), but at the end stage of HF, patients may experience shocks with increasing frequency and change the plan for end-of-life (EOL) care including the deactivation of the ICD. This report describes family members' experiences of patients with ICD making decisions at EOL. Understanding the decision-making of patients with ICD at EOL can promote informed decision-making and improve the quality of EOL care. This pilot study used a mixed methods approach to test the effects of a nurse-guided discussion in decision-making about ICD deactivation (turning off the defibrillation function) at the EOL. Interviews were conducted, audiotaped, and transcribed in 2012 to 2013 with 6 family members of patients with advanced HF and ICDs. Three researchers coded the data and identified themes in 2014. Three main themes described family members' experiences related to patients having HF with ICDs making health-care decision at EOL: decision-making preferences, patients' perception on ICD deactivation, and communication methods. Health-care providers need to have knowledge of patients' decision-making preferences. Preferences for decision-making include the allowing of appropriate people to involve and encourages direct conversation with family members even when advance directives is completed. Information of ICD function and the option of deactivation need to be clearly delivered to patients and family members. Education and guidelines will facilitate the communication of the preferences of EOL care.

  14. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  15. Management of radiation oncology patients with implanted cardiac pacemakers or implant able cardioverter defibrilators; Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores automaticos implantables

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.

    2012-07-01

    The increase in life expectancy along with the technological development in the last decades has resulted in an increase in the number of patients requiring pacemaker implants or implantable cardioverter defibrillators worldwide. An increase in the number of patients with implanted cardiac devices in radiotherapy is also expected due to the risk factors in common between heart disease and cancer. In 1994 the American Association of Physicists in Medicine (AAPM) released a report about the management of radiation oncology patients with implanted cardiac pacemakers. The addition of new technologies, both in radiotherapy units and in the manufacturing process of heart devices, has shown the need for an updated protocol for the management of these patients. In this work, the most important articles published after the report of the AAPM have been compiled, in order to analyze the effects not previously studied such as dose rate, scattered radiation, electromagnetic interference or random failures produced by neutrons and protons. Additionally, the latest recommendations given by the manufacturers have been analyzed and, finally, some indications are given as an updated guide for the management of radiation oncology patients with pacemakers or cardioverter defibrillators implanted. (Author)

  16. Performance of the 2015 International Task Force Consensus Statement Risk Stratification Algorithm for Implantable Cardioverter-Defibrillator Placement in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    Science.gov (United States)

    Orgeron, Gabriela M; Te Riele, Anneline; Tichnell, Crystal; Wang, Weijia; Murray, Brittney; Bhonsale, Aditya; Judge, Daniel P; Kamel, Ihab R; Zimmerman, Stephan L; Tandri, Harikrishna; Calkins, Hugh; James, Cynthia A

    2018-02-01

    Ventricular arrhythmias are a feared complication of arrhythmogenic right ventricular dysplasia/cardiomyopathy. In 2015, an International Task Force Consensus Statement proposed a risk stratification algorithm for implantable cardioverter-defibrillator placement in arrhythmogenic right ventricular dysplasia/cardiomyopathy. To evaluate performance of the algorithm, 365 arrhythmogenic right ventricular dysplasia/cardiomyopathy patients were classified as having a Class I, IIa, IIb, or III indication per the algorithm at baseline. Survival free from sustained ventricular arrhythmia (VT/VF) in follow-up was the primary outcome. Incidence of ventricular fibrillation/flutter cycle length the algorithm appropriately differentiated risk of VT/VF, incidence of VT/VF was underestimated (observed versus expected: 29.6 [95% confidence interval, 25.2-34.0] versus >10%/year Class I; 15.5 [confidence interval 11.1-21.6] versus 1% to 10%/year Class IIa). In addition, the algorithm did not differentiate survival free from ventricular fibrillation/flutter between Class I and IIa patients ( P =0.97) or for VT/VF in Class I and IIa primary prevention patients ( P =0.22). Adding Holter results (the algorithm differentiates arrhythmic risk well overall, it did not distinguish ventricular fibrillation/flutter risks of patients with Class I and IIa implantable cardioverter-defibrillator indications. Limited differentiation was seen for primary prevention cases. As these are vital uncertainties in clinical decision-making, refinements to the algorithm are suggested prior to implementation. © 2018 American Heart Association, Inc.

  17. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  18. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter defibrillator in Swine.

    Science.gov (United States)

    Killingsworth, Cheryl R; Melnick, Sharon B; Litovsky, Silvio H; Ideker, Raymond E; Walcott, Gregory P

    2013-10-01

    A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. During sinus rhythm, anesthetized pigs (38 ± 6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24 hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semiquantitative scoring. Troponin I was significantly elevated at 4 hours and 24 hours (22.6 ± 16.3 ng/mL and 3.1 ± 1.3 ng/mL; baseline 0.07 ± 0.09 ng/mL) in control pigs but not in S-ICD pigs (0.12 ± 0.11 ng/mL and 0.13 ± 0.13 ng/mL; baseline 0.06 ± 0.03 ng/mL). CK-MM was significantly elevated in S-ICD pigs after shocks (6,544 ± 1,496 U/L and 9,705 ± 6,240 U/L; baseline 704 ± 398 U/L) but not in controls. Electrocardiogram changes occurred postshock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  19. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter-defibrillator in swine

    Science.gov (United States)

    KILLINGSWORTH, CHERYL R.; MELNICK, SHARON B.; LITOVSKY, SILVIO H.; IDEKER, RAYMOND E.; WALCOTT, GREGORY P.

    2013-01-01

    Background A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. Methods During sinus rhythm, anesthetized pigs (38±6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24-hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semi-quantitative scoring. Results Troponin I was significantly elevated at 4- and 24-hours (22.6±16.3 and 3.1±1.3 ng/ml; baseline 0.07±0.09 ng/ml) in control pigs but not in S-ICD pigs (0.12±0.11 and 0.13±0.13 ng/ml; baseline 0.06±0.03 ng/ml). CK-MM was significantly elevated in S-ICD pigs after shocks (6544±1496 and 9705±6240 U/L; baseline 704±398 U/L) but not in controls. ECG changes occurred post-shock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Conclusion Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. PMID:23713608

  20. [Impact of metoprolol use in the treatment of patients with electrical-storm after cardioverter defibrillators implantation].

    Science.gov (United States)

    Yu, Jin-bo; Yang, Bing; Xu, Dong-jie; Chen, Ming-long; Shan, Qi-jun; Zou, Jian-gang; Chen, Chun; Zhang, Feng-xiang; Hou, Xiao-feng; Li, Wen-qi; Zhang, Rong; Cao, Ke-jiang

    2011-08-01

    To explore the effectiveness of the metoprolol dosage adjustment on reducing the incidence of electrical-storm (ES) in patients with Implantable Cardioverter Defibrillators (ICDs). Data from patients with ICD implantation between Jan, 2003 and Jun, 2006 in our hospital were retrospectively analyzed. ES was defined as either ≥ 3 times of ventricular tachyarrhythmias (VTAs) resulting in ICD therapy or VTAs lasting more than 30 s detected by ICD without any therapy within 24 hours. During a follow-up period of (27.5 ± 21.2) months, ES was recorded in 39 cases [34 males, average age (52.0 ± 13.1) years] out of 119 patients (32.8%) and 9 patients died after ES. During the period of storm attack, ES was successfully controlled in 25/30 patients by various interventions, including predisposing factors corrected in 5 cases, ICD reprogramming and antiarrhythmic drugs therapy optimized in 16 cases (one received intravenous injection of metoprolol), and VTAs eliminated by catheter ablation in 4 cases. ES was spontaneously resolved in the remaining 5 cases. In the chronic phase, 2 patients with Brugada syndrome were treated with Quinidine mono-therapy while the dosage of metoprolol was adjusted in the remaining 23 patients and the dosage of metoprolol was increased gradually from (26.8 ± 13.9) mg/d to (88.9 ± 53.5) mg/d without any adverse effects (9 patients received also oral amiodarone 200 mg/d). Post dosage adjustment, the total VTA episodes [(1.9 ± 1.7) times/month vs. (0.8 ± 0.6) times/month, P = 0.004], incidence of antitachycardia pacing therapies [(4.2 ± 3.8) runs/month vs. (2.3 ± 2.0) runs/month, P = 0.003], as well as electrical cardioversion or defibrillation [(1.1 ± 0.9) times/month vs. (0.4 ± 0.2) times/month, P = 0.001] were significantly decreased. ES was not controlled until a extremely high dosage [225 - 300 (255.3 ± 41.7) mg/d] of metoprolol was reached in the remaining 5 patients. Metoprolol use is essential and its dosage should be

  1. The healthcare utilization and cost of treating patients experiencing inappropriate implantable cardioverter defibrillator shocks: a propensity score study.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Giedrimiene, Dalia; Coleman, Craig I; Guertin, Danette; Azeem, Meena; Kluger, Jeffrey

    2014-10-01

    Inappropriate shocks (IASs) from implantable cardioverter defibrillators (ICDs) are associated with decreased quality of life, but whether they increase healthcare utilization and treatment costs is unknown. We sought to determine the impact of IASs on subsequent healthcare utilization and treatment costs. We conducted a case-control analysis of ICD patients at a single institution from 1997 to 2010 and who had ≥12 months of post-ICD implant follow-up. Cases included all patients experiencing an IAS during the first 12 months after implantation. Eligible control patients did not receive a shock of any kind during the 12 months after implantation. Propensity scores based on 36 covariates (area under curve = 0.78) were used to match cases to controls. We compared the rate (occurrences/person year [PY]) of healthcare utilization immediately following IAS to the end of the 12-month follow-up period to the rate in the no-shock group over 12 months of follow-up. We also compared 12-month postimplant treatment (outpatient clinic, emergency room, and hospitalization) costs in both groups. A total of 76 patients experiencing ≥1 IAS during the first 12 months after implant (contributing 48 PYs) were matched to 76 no-shock patients (contributing 76 PYs). Cardiovascular (CV)-related clinic visit and hospitalization rates were increased following an IAS compared to those not receiving a shock (4.0 vs 3.3 and 0.7 vs 0.5, respectively, P = 0.02 for both). CV-related emergency room visitation (0.15 vs 0.08) rates were also numerically higher following an IAS, but did not reach statistical significance (P = 0.26). Patients experiencing an IAS accrued greater treatment costs during the 12 months postimplant compared to no-shock patients ($13,973 ± $46,345 vs $6,790 ± $19,091, P = 0.001). Recipients of IAS utilize the healthcare system more frequently following an IAS than patients not experiencing a shock. This increased utilization results in higher costs of treating IAS

  2. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  3. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H.; Pedersen, Susanne S.; van der Tweel, Ingeborg

    2016-01-01

    -reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients...... programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved...... during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life....

  4. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  5. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz.

    Science.gov (United States)

    Katrib, J; Nadi, M; Kourtiche, D; Magne, I; Schmitt, P; Souques, M; Roth, P

    2013-10-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.

  6. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB). BACKGROUND: Limited data exist regarding the benefit of CRT-D in patients with IAT. METHODS: The benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of......-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p

  7. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?

    DEFF Research Database (Denmark)

    Philbert, Berit Thornvig; Tfelt-Hansen, Jacob; Jacobsen, Peter K

    2017-01-01

    Inappropriate implantable cardioverter-defibrillator (ICD) shock therapy is painful, stressful, and typically occurs unexpected in conscious patients and may be related to a less favourable prognosis. In our institution, we have observed four cases of multiple inappropriate ICD shocks during reset...... a ventricular fibrillation (VF) zone starting at 146 b.p.m., with shock therapy only and changes in sensitivity settings making the ICD more sensitive. In all cases, the reason for the multiple inappropriate shocks was that the VF zone was reached due to exercise-induced sinus tachycardia or due to oversensing...... during sinus rhythm. The VVI backup mode has to balance between protection from failure of ICD therapy during life-threatening ventricular arrhythmias and from inappropriate shocks. It seems the non-programmable parameters in VVI backup mode of St Jude Medical ICDs carry an unacceptable high risk...

  8. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J; Jordaens, Luc; Pedersen, Susanne S

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 and 2010, 448 consecutively implanted ICD patients were enrolled in the prospective Mood and personality as precipitants of arrhythmia in patients with an Implantable cardioverter Defibrillator: A prospective Study (MIDAS), of which 429 completed the Hospital Anxiety and Depression Scale (HADS) and the ICD Patient Concerns questionnaire (ICDC) at baseline. Eighty per cent of all patients received beta-blocker therapy. In univariate analysis, beta-blocker therapy was not significantly associated with symptoms of anxiety, depression, and ICD concerns (β = -0.030, β = 0.007, and β = -0.045, respectively; all P's >0.36). Type of beta-blocker showed a trend towards significance for mean levels of ICD concerns (P = 0.09). No association was found between dosage and emotional distress (all P's >0.21). After adjustment for relevant clinical and demographic variables, the association of beta-blocker therapy and symptoms of anxiety, depression, and ICD concerns remained non-significant (β = 0.009, β = 0.037, and β = 0.019, respectively; all P's >0.47). In patients receiving an ICD, beta-blocker therapy was not associated with symptoms of anxiety, depression, and ICD concerns. Research is warranted that further elucidates the link between beta-blocker therapy and emotional distress in this vulnerable patient group.

  9. Implantable Cardioverter-defibrillator Therapy for Hypertrophic Cardiomyopathy: Usefulness in Primary and Secondary Prevention.

    Science.gov (United States)

    Sarrias, Axel; Galve, Enrique; Sabaté, Xavier; Moya, Àngel; Anguera, Ignacio; Núñez, Elaine; Villuendas, Roger; Alcalde, Óscar; García-Dorado, David

    2015-06-01

    Hypertrophic cardiomyopathy is a frequent cause of sudden death. Clinical practice guidelines indicate defibrillator implantation for primary prevention in patients with 1 or more risk factors and for secondary prevention in patients with a history of aborted sudden death or sustained ventricular arrhythmias. The aim of the present study was to analyze the follow-up of patients who received an implantable defibrillator following the current guidelines in nonreferral centers for this disease. This retrospective observational study included all patients who underwent defibrillator implantation between January 1996 and December 2012 in 3 centers in the province of Barcelona. The study included 69 patients (mean age [standard deviation], 44.8 [17] years; 79.3% men), 48 in primary prevention and 21 in secondary prevention. The mean number of risk factors per patient was 1.8 in the primary prevention group and 0.5 in the secondary prevention group (P=.029). The median follow-up duration was 40.5 months. The appropriate therapy rate was 32.7/100 patient-years in secondary prevention and 1.7/100 patient-years in primary prevention (P<.001). Overall mortality was 10.1%. Implant-related complications were experienced by 8.7% of patients, and 13% had inappropriate defibrillator discharges. In patients with a defibrillator for primary prevention, the appropriate therapy rate is extremely low, indicating the low predictive power of the current risk stratification criteria. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... interfere with an ICD include: Cell phones and MP3 players (for example, iPods) Household appliances, such as ... experts recommend not putting your cell phone or MP3 player in a shirt pocket over your ICD ( ...

  11. Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study.

    Science.gov (United States)

    Carbucicchio, Corrado; Santamaria, Matteo; Trevisi, Nicola; Maccabelli, Giuseppe; Giraldi, Francesco; Fassini, Gaetano; Riva, Stefania; Moltrasio, Massimo; Cireddu, Manuela; Veglia, Fabrizio; Della Bella, Paolo

    2008-01-29

    Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing > or = 1 clinical VT still inducible after catheter ablation. Advanced strategies of catheter ablation

  12. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Alzand, B S N; Timmermans, C C M M; Wellens, H J J; Dennert, R; Philippens, S A M; Portegijs, P J M; Rodriguez, L M

    2011-08-01

    The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Catheter-based substrate modification using voltage mapping results in a long-lasting reduction

  13. [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla].

    Science.gov (United States)

    Nordbeck, P; Bauer, W R

    2008-03-01

    Magnetic resonance imaging (MRI) is increasingly used in patients, but it is contraindicated in those with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD). This study examined circumstances in which potentially life-threatening arrhythmias may be triggered in patients with CP undergoing MRI and whether these problems can be avoided by reprogramming of these devices. Eight CP and seven ICDs were investigated in a phantom at 1.5 tesla (experimental and imaging sequences). A decrease in battery voltage was found in four CP after MRI (indication for elective replacement). Additionally, three showed changes in programming (resets). Analogous changes did not appear in the tested ICDs, but periods of tachycardia were recorded in all types of devices during MRI depending on the pulse sequence employed. MRI-related electromagnetic fields as used in routine MRI can induce severe pacemaker device malfunctions. Device programming approaches are unreliable for prevention of patient hazards, as programming changes or resets are one of the primary malfunctions during MRI.

  14. Importance of beta-blocker dose in prevention of ventricular tachyarrhythmias, heart failure hospitalizations, and death in primary prevention implantable cardioverter-defibrillator recipients

    DEFF Research Database (Denmark)

    Ruwald, A C; Gislason, G H; Vinther, M

    2018-01-01

    Aims: There is a paucity of studies investigating a dose-dependent association between beta-blocker therapy and risk of outcome. In a nationwide cohort of primary prevention implantable cardioverter-defibrillator (ICD) patients, we aimed to investigate the dose-dependent association between beta-blocker...... therapy and risk of ventricular tachyarrhythmias (VT/VF), heart failure (HF) hospitalizations, and death. Methods and results: Information on ICD implantation, endpoints, comorbidities, beta-blocker usage, type, and dose were obtained through Danish nationwide registers. The two major beta-blockers...... carvedilol and metoprolol were examined in three dose levels; low (metoprolol ≤ 25 mg; carvedilol ≤ 12.5 mg), intermediate (metoprolol 26-199 mg; carvedilol 12.6-49.9 mg), and high (metoprolol ≥ 200 mg; carvedilol ≥ 50 mg). Time to events was investigated utilizing multivariate Cox models with beta-blocker...

  15. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association.

    Science.gov (United States)

    Dunbar, Sandra B; Dougherty, Cynthia M; Sears, Samuel F; Carroll, Diane L; Goldstein, Nathan E; Mark, Daniel B; McDaniel, George; Pressler, Susan J; Schron, Eleanor; Wang, Paul; Zeigler, Vicki L

    2012-10-23

    Significant mortality benefits have been documented in recipients of implantable cardioverter defibrillators (ICDs); however, the psychosocial distress created by the underlying arrhythmia and its potential treatments in patients and family members may be underappreciated by clinical care teams. The disentanglement of cardiac disease and device-related concerns is difficult. The majority of ICD patients and families successfully adjust to the ICD, but optimal care pathways may require additional psychosocial attention to all ICD patients and particularly those experiencing psychosocial distress. This state-of-the-science report was developed on the basis of an analysis and critique of existing science to (1) describe the psychological and quality-of-life outcomes after receipt of an ICD and describe related factors, such as patient characteristics; (2) describe the concerns and educational/informational needs of ICD patients and their family members; (3) outline the evidence that supports interventions for improving educational and psychological outcomes for ICD patients; (4) provide recommendations for clinical approaches for improving patient outcomes; and (5) identify priorities for future research in this area. The ultimate goal of this statement is to improve the precision of identification and care of psychosocial distress in ICD patients to maximize the derived benefit of the ICD.

  16. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui

    2016-09-30

    Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

  17. Design and Methods for a Pilot Study of a Phone-Delivered, Mindfulness-Based Intervention in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Elena Salmoirago-Blotcher

    2012-01-01

    Full Text Available Background. Meditation practices are associated with a reduction in adrenergic activity that may benefit patients with severe cardiac arrhythmias. This paper describes the design and methods of a pilot study testing the feasibility of a phone-delivered mindfulness-based intervention (MBI for treatment of anxiety in patients with implantable cardioverter defibrillators (ICDs. Design and Methods. Consecutive, clinically stable outpatients (n=52 will be screened for study eligibility within a month of an ICD-related procedure or ICD shock and will be randomly assigned to MBI or to usual care. MBI patients will receive eight weekly individual phone sessions based on two mindfulness practices (awareness of breath and body scan plus home practice with a CD for 20 minutes daily. Patients assigned to usual care will be offered the standard care planned by the hospital. Assessments will occur at baseline and at the completion of the intervention (between 9 and 12 weeks after randomization. The primary study outcome is feasibility; secondary outcomes include anxiety, mindfulness, and number of administered shocks during the intervention period. Conclusions. If proven feasible and effective, phone-delivered mindfulness-based interventions could improve psychological distress in ICD outpatients with serious cardiovascular conditions.

  18. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  19. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication.

    Science.gov (United States)

    Quast, Anne-Floor B E; Tjong, Fleur V Y; Koop, Brendan E; Wilde, Arthur A M; Knops, Reinoud E; Burke, Martin C

    2018-02-14

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and S-ICD orientation. This study is designed to evaluate the orientation of the LP and S-ICD in canine subjects and measure success and threshold of intrabody communication. To gain more human insights, we will explore device orientation in LP and S-ICD patients. Canine subjects implanted with a prototype S-ICD and LP (both Boston Scientific, MA, USA) with anterior-posterior fluoroscopy images were included in this analysis. For comparison, a retrospective analysis of human S-ICD and LP patients was performed. The angle of the long axis of the LP towards the vertical axis of 0°, and distance between the coil and LP were measured. Twenty-three canine subjects were analysed. Median angle of the LP was 29° and median distance of the S-ICD coil to LP was 0.8 cm. All canine subjects had successful communication. The median communicating threshold was 2.5 V. In the human retrospective analysis, 72 LP patients and 100 S-ICD patients were included. The mean angle of the LP was 56° and the median distance between the S-ICD coil and LP was 4.6 cm. Despite the less favourable LP orientation in canine subjects, all communication attempts were successful. In the human subjects, we observed a greater and in theory more favourable LP angle towards the communication vector. These data suggests suitability of human anatomy for conductive intrabody communication.

  20. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  1. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  2. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  4. Manual for the psychotherapeutic treatment of acute and post-traumatic stress disorders following multiple shocks from implantable cardioverter defibrillator (ICD).

    Science.gov (United States)

    Jordan, Jochen; Titscher, Georg; Peregrinova, Ludmila; Kirsch, Holger

    2013-01-01

    In view of the increasing number of implanted cardioverter defibrillators (ICD), the number of people suffering from so-called "multiple ICD shocks" is also increasing. The delivery of more than five shocks (appropriate or inappropriate) in 12 months or three or more shocks (so called multiple shocks) in a short time period (24 hours) leads to an increasing number of patients suffering from severe psychological distress (anxiety disorder, panic disorder, adjustment disorder, post-traumatic stress disorder). Untreated persons show chronic disease processes and a low rate of spontaneous remission and have an increased morbidity and mortality. Few papers have been published concerning the psychotherapeutic treatment for these patients. The aim of this study is to develop a psychotherapeutic treatment for patients with a post-traumatic stress disorder or adjustment disorder after multiple ICD shocks. Explorative feasibility study: Treatment of 22 patients as a natural design without randomisation and without control group. The period of recruitment was three years, from March 2007 to March 2010. The study consisted of two phases: in the first phase (pilot study) we tested different components and dosages of psychotherapeutic treatments. The final intervention programme is presented in this paper. In the second phase (follow-up study) we assessed the residual post-traumatic stress symptoms in these ICD patients. The time between treatment and follow-up measurement was 12 to 30 months. Thirty-one patients were assigned to the Department of Psychocardiology after multiple shocks. The sample consisted of 22 patients who had a post-traumatic stress disorder or an adjustment disorder and were willing and able to participate. They were invited for psychological treatment. 18 of them could be included into the follow-up study. After the clinical assessment at the beginning and at the end of the inpatient treatment a post-treatment assessment with questionnaires followed. In

  5. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  7. Sex and Race/Ethnicity Differences in Implantable Cardioverter-Defibrillator Counseling and Use Among Patients Hospitalized With Heart Failure: Findings from the Get With The Guidelines-Heart Failure Program.

    Science.gov (United States)

    Hess, Paul L; Hernandez, Adrian F; Bhatt, Deepak L; Hellkamp, Anne S; Yancy, Clyde W; Schwamm, Lee H; Peterson, Eric D; Schulte, Phillip J; Fonarow, Gregg C; Al-Khatib, Sana M

    2016-08-16

    Previous studies have found that women and black patients eligible for a primary prevention implantable cardioverter-defibrillator (ICD) are less likely than men or white patients to receive one. We performed an observational analysis of the Get With The Guidelines-Heart Failure Program from January 1, 2011, to March 21, 2014. Patients admitted with heart failure and an ejection fraction ≤35% without an ICD were included. Rates of ICD counseling among eligible patients and ICD receipt among counseled patients were examined by sex and race/ethnicity. Among 21 059 patients from 236 sites, 4755 (22.6%) received predischarge ICD counseling. Women were counseled less frequently than men (19.3% versus 24.6%, Prace/ethnic group 14.4% versus white 24.3%, Pdifferences by race and ethnicity persisted. © 2016 American Heart Association, Inc.

  8. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial: concept and design of a randomized, controlled trial of intra-operative defibrillation testing during de novo defibrillator implantation.

    Science.gov (United States)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan; Bode, Frank; Svendsen, Jesper Hastrup; Felk, Angelika; Hauser, Tino; Wegscheider, Karl

    2015-01-01

    Although defibrillation (DF) testing is still considered a standard procedure during implantable cardioverter-defibrillator (ICD) insertion and has been an essential element of all trials that demonstrated the survival benefit of ICD therapy, there are no large randomized clinical trials demonstrating that DF testing improves clinical outcome and if the outcome would remain the same by omitting DF testing. Between February 2011 and July 2013, we randomly assigned 1077 patients to ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint was the average efficacy of the first ICD shock for all true VT/VF episodes in each patient during follow-up. The secondary endpoints included the frequency of system revisions, total fluoroscopy, implantation time, procedural serious adverse events, and all-cause, cardiac, and arrhythmic mortality during follow-up. Home Monitoring was used in all patients to continuously monitor the system integrity, device programming and performance. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial is one of two large prospective randomized trials assessing the effect of DF testing omission during ICD implantation. NCT01282918. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email

  9. Development and evaluation of the EOL-ICDQ as a measure of experiences, attitudes and knowledge in end-of-life in patients living with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Thylén, Ingela; Wenemark, Marika; Fluur, Christina; Strömberg, Anna; Bolse, Kärstin; Årestedt, Kristofer

    2014-04-01

    Due to extended indications and resynchronization therapy, many implantable cardioverter defibrillator (ICD) recipients will experience progressive co-morbid conditions and will be more likely to die of causes other than cardiac death. It is therefore important to elucidate the ICD patients' preferences when nearing end-of-life. Instead of avoiding the subject of end-of-life, a validated questionnaire may be helpful to explore patients' experiences and attitudes about end-of-life concerns and to assess knowledge of the function of the ICD in end-of-life. Validated instruments assessing patients' perspective concerning end-of-life issues are scarce. The purpose of this study was to develop and evaluate respondent satisfaction and measurement properties of the 'Experiences, Attitudes and Knowledge of End-of-Life Issues in Implantable Cardioverter Defibrillator Patients' Questionnaire' (EOL-ICDQ). The instrument was tested for validity, respondent satisfaction, and for homogeneity and stability in the Swedish language. An English version of the EOL-ICDQ was validated, but has not yet been pilot tested. The final instrument contained three domains, which were clustered into 39 items measuring: experiences (10 items), attitudes (18 items), and knowledge (11 items) of end-of-life concerns in ICD patients. In addition, the questionnaire also contained items on socio-demographic background (six items) and ICD-specific background (eight items). The validity and reliability properties were considered sufficient. The EOL-ICDQ has the potential to be used in clinical practice and future research. Further studies are needed using this instrument in an Anglo-Saxon context with a sample of English-speaking ICD recipients.

  10. Clinical safety of an MRI conditional implantable cardioverter defibrillator system: A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study (MIMI).

    Science.gov (United States)

    Kypta, Alexander; Blessberger, Hermann; Hoenig, Simon; Saleh, Karim; Lambert, Thomas; Kammler, Juergen; Fellner, Franz; Lichtenauer, Michael; Steinwender, Clemens

    2016-03-01

    The aim of this study was to evaluate the safety and efficacy of the Lumax 740(®) Implantable Cardioverter Defibrillator (ICD) system in patients undergoing a defined 1.5 Tesla (T) MRI. Between November 2013 and April 2014, eighteen patients (age range, 41-78 years; mean age, 64 years) implanted with a Lumax 740(®) ICD system for at least 6 weeks before an MRI were enrolled into this single-center feasibility study. The local ethics committee approved the study before patients gave written informed consent. Patients underwent defined MRI 1.5T of the brain and lower lumbar spine with three safety follow-up evaluations obtained during the 3-month study period. Data were analyzed descriptively. Study endpoints were the absence of either MRI and pacing system related serious adverse device effects (SADE), or of a ventricular pacing threshold increase >0.5V, or of an R-wave amplitude attenuation battery status. Sixteen patients completed the MRI and the follow-up period. As no SADE occurred, the SADE free rate was 100%. Freedom from ventricular pacing threshold increase was 100% (16/16; 95%CI: 82.9%; 100.0%). There were no significant differences between baseline and follow-up measurements of sensing amplitudes (-0.58 ± 2.07 mV, P = 0.239, -0.41 ± 1.04 mV, P = 0.133, and -0.25 ± 1.36 mV, P = 0.724, for immediately after, 1 month and 3 months after MRI scan, respectively) and pacing thresholds (-0.047 ± 0.18 V, P = 0.317, -0.019 ± 0.11 V, P = 0.490, and 0.075 ± 0.19 V, P = 0.070, for immediately after, 1 month and 3 months after MRI scan, respectively). Lead impedances after the MRI scan were significantly lower as compared with baseline values (-22.8 ± 21.69 Ω, P = 0.001, -21.62 ± 39.71 Ω, P = 0.040, and -33.68 ± 57.73 Ω, P = 0.018, for immediately after, 1 month and 3 months after MRI scan, respectively). MRI scans in patients with MRI conditional ICD system (Lumax 740(

  11. Subcutaneous Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... discriminator functions and lacks antitachycardia pacing. Expanded Programmability Programming that allows lower shock energies and the ability ... 2014 American Heart Association, Inc. References 1. ↵ Weiss R , Knight BP , Gold MR , Leon AR , Herre JM , ...

  12. [Current malaria situation in Turkey].

    Science.gov (United States)

    Gockchinar, T; Kalipsi, S

    2001-01-01

    Geographically, Turkey is situated in an area where malaria is very risky. The climatic conditions in the region are suitable for the malaria vector to proliferate. Due to agricultural infrastructural changes, GAP and other similar projects, insufficient environmental conditions, urbanization, national and international population moves, are a key to manage malaria control activities. It is estimated that malaria will be a potential danger for Turkey in the forthcoming years. The disease is located largely in south-eastern Anatolia. The Diyarbakir, Batman, Sanliurfa, Siirt, and Mardin districts are the most affected areas. In western districts, like Aydin and Manisa, an increase in the number of indigenous cases can be observed from time to time. This is due to workers moving from malaria districts to western parts to final work. Since these workers cannot be controlled, the population living in these regions get infected from indigenous cases. There were 84,345 malaria cases in 1994 and 82,096 in 1995, they decreased to 60,884 in 1996 and numbered 35,456 in 1997. They accounted for 36,842 and 20,963 in 1998 and 1999, respectively. In Turkey there are almost all cases of P. vivax malaria. There are also P. vivax and P. falciparum malaria cases coming from other countries: There were 321 P. vivax cases, including 2 P. falciparum ones, arriving to Turkey from Iraq in 1995. The P. vivax malaria cases accounted for 229 in 1996, and 67, cases P. vivax including 12 P. falciparum cases, in 1997, and 4 P. vivax cases in 1998 that came from that country. One P. vivax case entered Turkey from Georgia in 1998. The cause of higher incidence of P. vivax cases in 1995, it decreasing in 1999, is the lack of border controls over workers coming to Turkey. The other internationally imported cases are from Syria, Sudan, Pakistan, Afghanistan, Nigeria, India, Azerbaijan, Malaysia, Ghana, Indonesia, Yemen. Our examinations have shown that none of these internationally imported cases

  13. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  14. Current situation on the glueball research

    International Nuclear Information System (INIS)

    Shen Qixing

    1991-01-01

    The current situation on the glueball research is reviewed. The emphases are some qualitative guidances to identify the glueball and several possible candidate states for the glueball which have been discovered in the experiments

  15. Diagnostic Value of MRI in Patients With Implanted Pacemakers and Implantable Cardioverter-Defibrillators Across a Cross Population: Does the Benefit Justify the Risk? A Proof of Concept Study.

    Science.gov (United States)

    Samar, Huma; Yamrozik, June A; Williams, Ronald B; Doyle, Mark; Shah, Moneal; Bonnet, Christopher A; Biederman, Robert W W

    2017-09-01

    The objective of this study was to assess the diagnostic usefulness of thoracic and nonthoracic magnetic resonance imaging (MRI) imaging in patients with implantable cardiac devices (permanent pacemaker or implantable cardioverter-defibrillators [ICDs]) to determine if there was a substantial benefit to patients with regard to diagnosis and/or management. MRI is infrequently performed on patients with conventional pacemakers or ICDs. Multiple studies have documented the safety of MRI scans in patients with implanted devices, yet the diagnostic value of this approach has not been established. Evaluation data were acquired in 136 patients with implanted cardiac devices who underwent MRIs during a 10-year period at a single institution. Specific criteria were followed for all patients to objectively define if the diagnosis by MRI enhanced patient care; 4 questions were answered after scan interpretation by both MRI technologists and MRI physicians who performed the scan. 1) Did the primary diagnosis change? 2) Did the MRI provide additional information to the existing diagnosis? 3) Was the pre-MRI (tentative) diagnosis confirmed? 4) Did patient management change? If "Yes" was answered to any of the preceding questions, the MRI scan was considered to be of value to patient diagnosis and/or therapy. In 97% (n = 132) of patients, MR added value to patient diagnosis and management. In 49% (n = 67) of patients, MRI added additional valuable information to the primary diagnosis, and in 30% (n = 41) of patients, MRI changed the principle diagnosis and subsequent management of the patient. No safety issues were encountered, and no adverse effects of undergoing the MRI scan were noted in any patient. MRI in patients with implanted pacemakers and defibrillators added value to patient diagnosis and management, which justified the risk of the procedure. Published by Elsevier Inc.

  16. Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

    Science.gov (United States)

    Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E

    2013-05-28

    The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Antibacterial Envelope Is Associated With Low Infection Rates After Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy Device Replacement: Results of the Citadel and Centurion Studies.

    Science.gov (United States)

    Henrikson, Charles A; Sohail, M Rizwan; Acosta, Helbert; Johnson, Eric E; Rosenthal, Lawrence; Pachulski, Roman; Dan, Dan; Paladino, Walter; Khairallah, Farhat S; Gleed, Kent; Hanna, Ibrahim; Cheng, Alan; Lexcen, Daniel R; Simons, Grant R

    2017-10-01

    This study sought to determine whether the nonabsorbable TYRX Antibacterial Envelope (TYRX) reduces major cardiovascular implantable electronic device (CIED) infections 12 months after implant. TYRX is a monofilament polypropylene mesh impregnated with minocycline and rifampin specifically designed to hold a CIED in place and elute antimicrobials over time. There are limited data on its ability to reduce CIED infections. We prospectively enrolled patients who underwent generator replacement with an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT), treated with TYRX. The primary endpoints were major CIED infection and CIED mechanical complications. Given the differences in infection rates among ICD and CRT patients, 3 different control populations were used: a published benchmark rate for ICD patients, and both site-matched and comorbidity-matched controls groups for CRT patients. Overall, a major CIED infection occurred in 5 of 1,129 patients treated with TYRX (0.4%; 95% confidence interval: 0.0% to 0.9%), significantly lower than the 12-month benchmark rate of 2.2% (p = 0.0023). Among the TYRX-treated CRT cohort, the major CIED infection rate was 0.7% compared with an infection rate of 1.0% and 1.3% (p = 0.38 and p = 0.02) in site-matched and comorbidity-matched control groups, respectively. Among the ICD group, the 12-month infection rate was 0.2% compared with the published benchmark of 2.2% (p = 0.0052). The most common CIED mechanical complication in study patients was pocket hematoma, which occurred in 18 of the 1,129 patients (1.6%; 95% confidence interval: 0.8 to 2.5), which is comparable with a published rate of 1.6%. Use of TYRX was associated with a lower major CIED infection rate. (TYRX™ Envelope for Prevention of Infection Following Replacement With a CRT or ICD; [Centurion]; NCT01043861/NCT01043705). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  18. Prophylactic catheter ablation of ventricular tachycardia before cardioverter-defibrillator implantation in patients with non-ischemic cardiomyopathy: Clinical outcomes after a single endocardial ablation

    Directory of Open Access Journals (Sweden)

    Atsushi Suzuki, MD

    2015-06-01

    Conclusion: Single endocardial PCA can decrease ES occurrence in NICM patients. However, high rates of VT recurrence and low success rates are issues to be resolved; therefore, the efficacy of single endocardial PCA is currently limited.

  19. Current Taxonomical Situation of Streptococcus suis.

    Science.gov (United States)

    Okura, Masatoshi; Osaki, Makoto; Nomoto, Ryohei; Arai, Sakura; Osawa, Ro; Sekizaki, Tsutomu; Takamatsu, Daisuke

    2016-06-24

    Streptococcus suis, a major porcine pathogen and an important zoonotic agent, is considered to be composed of phenotypically and genetically diverse strains. However, recent studies reported several "S. suis-like strains" that were identified as S. suis by commonly used methods for the identification of this bacterium, but were regarded as distinct species from S. suis according to the standards of several taxonomic analyses. Furthermore, it has been suggested that some S. suis-like strains can be assigned to several novel species. In this review, we discuss the current taxonomical situation of S. suis with a focus on (1) the classification history of the taxon of S. suis; (2) S. suis-like strains revealed by taxonomic analyses; (3) methods for detecting and identifying this species, including a novel method that can distinguish S. suis isolates from S. suis-like strains; and (4) current topics on the reclassification of S. suis-like strains.

  20. Biosimilars in Dermatology: Current Situation (Part I).

    Science.gov (United States)

    Puig, L; Carretero, G; Daudén, E; Ferrándiz, C; Marrón, S E; Martorell, A; Pérez-Suárez, B; Rodriguez-Cerdeira, C; Ruiz-Villaverde, R; Sánchez-Carazo, J L; Velasco, M

    2015-09-01

    The first biosimilar version of a biologic agent used to treat psoriasis (infliximab) entered the Spanish market on February 16 of this year, and more biosimilars can be expected to follow in the coming months and years. Logically, this new situation will have economic repercussions and alter prescribing patterns among dermatologists. In this article, we review regulatory issues related to the approval of biosimilars, with a particular focus on the situation in the European Union. We will examine analytical characterization studies and special considerations for clinical trials with biosimilars, and also look at several somewhat contentious issues, such as the extrapolation of indications, interchangeability, and automatic substitution. Finally, we will review the biosimilars with indications for psoriasis currently in the clinical development pipeline and assess their potential to offer comparable efficacy and safety to the reference product while contributing to the sustainability of the public health care system. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  1. [Current situation of acupuncture in New Zealand].

    Science.gov (United States)

    Li, Xiaoji; Hu, Youping

    2017-04-12

    The beginning of TCM acupuncture in New Zealand dates back to the middle of 19th century. After self-improvement for more than 100 years, TCM acupuncture has gained a considerable development. From the perspective of history and current situation, the development of acupuncture in New Zealand was elaborated in this article; in addition, the sustainable development of acupuncture was discussed from the perspective of education and training. In New Zealand, the TCM acupuncture and dry needling have played a dominant role in acupuncture treatments, which are practiced by TCM practitioners and physical therapists. The TCM acupuncture is widely applied in department of internal medicine, surgery, gynecology, and pediatrics, etc., while the dry needling is li-mited for traumatology and pain disorder. Therefore, including TCM acupuncture into the public medical and educational system in New Zealand should be an essential policy of Ministry of Health to provide welfare for the people.

  2. Energy access. Current situation, challenges and outlook

    International Nuclear Information System (INIS)

    2014-07-01

    Globally over 1.3 billion people do not have access to electricity and 2.6 billion people rely on the traditional use of biomass for cooking. Energy access is one of the major challenges of the 21. century as it is a lever for both economic and human development, at individual and national level. Moreover, energy access represents a high-potential market and offers a lot of opportunities for private companies and industrials. In this publication, ENEA lays out the current situation of energy access (actors, actual and future needs, existing technological solutions, markets). The publication addresses the main issues energy access has to face: energy price, equipment financing, distribution, scale-up, and environmental performances

  3. Current Economic Situation in Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    Goran Mirascic

    2011-11-01

    Full Text Available This article provides an overview of the current economic situation in Bosnia and Herzegovina. Beginning in the second half of 2008, macroeconomic conditions in B&H began precipitating a decline in economic activity. While the global financial crisis was among the factors contributing to this decline, it was far from the only factor. Problematic macroeconomic conditions were also a result of B&H’s own structural and political problems, caused largely by the shortcomings of a political entity comprising two autonomous entities. Due to such problems, the governments of B&H turned to the International Monetary Fund for assistance. This article analyzes the effects of the first two “stand by” arrangements made between the IMF and B&H and discusses implications for further, ongoing stand by arrangements made between the IMF and B&H. This paper also examines the lack of unified economic space between The Federation of Bosnia and Herzegovina and The Republic of Srpska, which has resulted not only in ineffective monetary policy but also in different fiscal and taxation systems between the two entities. While various existing analyses claim that B&H has little hope of resolving its economic woes due to its current political and economic structure, this article offers solutions and measures that, if successfully implemented, would lead to more efficient recovery and self-sustainable economic growth.

  4. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, treatments and procedures related to heart disease and stroke. Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  5. Cardioverter-Defibrillator: A Treatment for Arrhythmia

    Science.gov (United States)

    ... abdomen (stomach area). It can go in a “pocket” under your skin or in a muscle. The ... counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom Checker BMI Calculator myhealthfinder Immunization Schedules Nutrient ...

  6. Current Situation of Medication Adherence in Hypertension.

    Science.gov (United States)

    Vrijens, Bernard; Antoniou, Sotiris; Burnier, Michel; de la Sierra, Alejandro; Volpe, Massimo

    2017-01-01

    Despite increased awareness, poor adherence to treatments for chronic diseases remains a global problem. Adherence issues are common in patients taking antihypertensive therapy and associated with increased risks of coronary and cerebrovascular events. Whilst there has been a gradual trend toward improved control of hypertension, the number of patients with blood pressure values above goal has remained constant. This has both personal and economic consequences. Medication adherence is a multifaceted issue and consists of three components: initiation, implementation, and persistence. A combination of methods is recommended to measure adherence, with electronic monitoring and drug measurement being the most accurate. Pill burden, resulting from free combinations of blood pressure lowering treatments, makes the daily routine of medication taking complex, which can be a barrier to optimal adherence. Single-pill fixed-dose combinations simplify the habit of medication taking and improve medication adherence. Re-packing of medication is also being utilized as a method of improving adherence. This paper presents the outcomes of discussions by a European group of experts on the current situation of medication adherence in hypertension.

  7. Current Situation of Edible Snails in Indonesia

    Directory of Open Access Journals (Sweden)

    Schneider, K.

    1999-01-01

    Full Text Available From March 7, 1995 to April 16, 1995 du ring the rainy season the utilisation of edible snails was investigated in Indonesia. To assess the current situation, the focus was put to answer the following questions : - Is it feasible under the present circumstances to domesticate these snails with the aim to conserve the natural resources ? - Could any individual or private initiative be enhanced or utilized ? - Would local disadvantaged groups (traditional animal farmers, women oryouths be benefitted through domestication of these snails ? - Is there any existing private organisation or NGO, which already gathers and trades the snails or would be interested to do this in the future ? Snails gatherers, -dealers and -farmers were visited and interviewed on the following topics using standardised questionnaires : Spreading and ecology ways of marketing, consumption habits, breeding and rearing. Diotopes were also visited and investigated. Results Spreading and ecology : Achatina fulica, Pomacea canaliculata, Pila ampullacea and Bellamia javanica are eaten. The snails can be found ail overJava. Ways of marketing : The snails gathered in the biotope are either marketed directly or through various marketing paths. A. fulica is exported in large quantifies. The population is therefore endangered. Consumption habits : Snails are not eaten regularly. Snail meat is known to be healthy. The consumption depends on the consumer's ethnie background. Breeding and rearing experience : with simple breeding systems for A. fulica and P. canaliculata are seldom found. The breeding of P. canaliculata is forbidden in Indonesia. There is no interest in breeding P. ampullacea or B. javanica. The breeding of A. fulica can ben-efit disadvantaged groups financially and help to conserving the natural snail population.

  8. CURRENT SITUATION OF MEDICINE III AND CHALLENGES

    Directory of Open Access Journals (Sweden)

    Lydia Masako Ferreira

    Full Text Available Objective: Describe the current situation of the area Medicine III of CAPES and detect challenges for the next four years of evaluation. Methods: The area's documents and reports of meetings were read from 2004 to 2013 Medicine III Capes as well as reports and evaluation form of each Postgraduate Program (PPG of the area and the sub-page of the area from the Capes website. The data relating to the evaluation process, the assessment form and faculty, student and scientific production data of all of Post-Graduate Programs of Medicine III were computed and analyzed. From these data were detected the challenges of the area for the next four years (2013-2016. Results: Among the 3,806 PPG, Medicine III had 41 PPG during last triennial evaluation and progressed from 18% to 43% of PPG very good or more concept (triennium 2001-2003 and 2010-2012. Most PPG were located in the South-East region (32, three in the South and two in the North-East. There was no PPG in North or Central-West regions. In 2013 and 2014 there were four approved Professional Master Degree Programs and one Master (M and Doctorate (PhD. The average of permanent professors was 558 teachers with about three students/professor. The number of PhD graduates has increased as well as the reason PhD/MD. The proportion of in high impact periodicals (A1, A2, B1 and B2 jumped from 30% to 50% demonstrating positive community response to the policy area. The challenges identified were: decrease regional asymmetry, increase the number of masters and doctors of excellence, reassessment of Brazilian journals, stimulate and set internationalization indicators, including post-doctors and definition of its indicators, the PPG nucleation analysis, PPG 3x3, include primary and secondary education, professional master and indicators of technological scientific production and solidarity. Conclusion: Medicine III has been scientifically consolidated and their scientific researchers demonstrated maturity

  9. CURRENT SITUATION OF MEDICINE III AND CHALLENGES.

    Science.gov (United States)

    Ferreira, Lydia Masako

    2015-01-01

    Describe the current situation of the area Medicine III of CAPES and detect challenges for the next four years of evaluation. The area's documents and reports of meetings were read from 2004 to 2013 Medicine III Capes as well as reports and evaluation form of each Postgraduate Program (PPG) of the area and the sub-page of the area from the Capes website. The data relating to the evaluation process, the assessment form and faculty, student and scientific production data of all of Post-Graduate Programs of Medicine III were computed and analyzed. From these data were detected the challenges of the area for the next four years (2013-2016). Among the 3,806 PPG, Medicine III had 41 PPG during last triennial evaluation and progressed from 18% to 43% of PPG very good or more concept (triennium 2001-2003 and 2010-2012). Most PPG were located in the South-East region (32), three in the South and two in the North-East. There was no PPG in North or Central-West regions. In 2013 and 2014 there were four approved Professional Master Degree Programs and one Master (M) and Doctorate (PhD). The average of permanent professors was 558 teachers with about three students/professor. The number of PhD graduates has increased as well as the reason PhD/MD. The proportion of in high impact periodicals (A1, A2, B1 and B2) jumped from 30% to 50% demonstrating positive community response to the policy area. The challenges identified were: decrease regional asymmetry, increase the number of masters and doctors of excellence, reassessment of Brazilian journals, stimulate and set internationalization indicators, including post-doctors and definition of its indicators, the PPG nucleation analysis, PPG 3x3, include primary and secondary education, professional master and indicators of technological scientific production and solidarity. Medicine III has been scientifically consolidated and their scientific researchers demonstrated maturity reaching a high level and matched to areas of greatest

  10. Current situation of radiation protection in Vietnam

    International Nuclear Information System (INIS)

    Tran, Toan Ngoc

    2008-01-01

    Vietnam was one of the earliest countries, who applied ionizing radiation in medicine, since 1923, Dr. Marie Curie had supplied radium sources to Hanoi cancer hospital for radiotherapy. However, we did not give sufficient attention to radiation protection involving, e.g. technology, legislation, until 1980s. Recently with the strong support from International Atomic Energy Agency (IAEA) and Vietnam government nuclear technology has been strongly and widely developed in different branches and radiation protection situation in Vietnam has been improved step by step. Strategy for Peaceful Utilization of Atomic Energy up to 2020 approved by the prime minister on January 3th, 2006 confirms that nuclear power plant will be put in operation by 2020. To ensure the implementation of the strategy, the first priority should be given to radiation protection and nuclear safety. This paper presents shortly some activities of radiation safety in Vietnam. The requirements for developing this field in Vietnam are also discussed. (author)

  11. Industrial safety, origins and current situation

    International Nuclear Information System (INIS)

    Gil Sarralbo, J. F.

    2011-01-01

    Basic Introduction to Industrial Safety, purpose and expected outcome. Concepts and fundamental principles that support it. Brief overview of its evolution over the course of history. The current legal basis in Spain for Industrial Safety. (Author) 4 refs.

  12. Current situation and industrialization of Taiwan nanotechnology

    International Nuclear Information System (INIS)

    Su, H.-N.; Lee, P.-C.; Tsai, M.-H.; Chien, K.-M.

    2007-01-01

    Nanotechnology is projected to be a very promising field, and the impact of nanotechnology on society is increasingly significant as the research funding and manufactured goods increase exponentially. A clearer picture of Taiwan's current and future nanotechnology industry is an essential component for future planning. Therefore, this investigation studies the progress of industrializing nanotechnology in Taiwan by surveying 150 companies. Along with understanding Taiwan's current nanotechnology industrialization, this paper also suggests ways to promote Taiwan's nanotechnology. The survey results are summarized and serve as the basis for planning a nanotechnology industrialization strategy

  13. Wilderness recreation use: the current situation

    Science.gov (United States)

    Joseph W. Roggenbuck; Alan E. Watson

    1989-01-01

    The total amount of recreational use of the National Wilderness Preservation System is currently at about 14.5 million visitor days per annum. Trends indicate a stable or declining overall use; use on a per acre basis is declining. The common stereotype of the wilderness user as young, wealthy, urban, leisured, and a nonresident of the State or region is largely...

  14. Childhood Obesity: Current Situation and Future Opportunities.

    Science.gov (United States)

    Koletzko, Berthold

    2016-07-01

    The early origins of overweight and obesity and the opportunities for early prevention are explored. Overweight and obesity prevalence globally has increased at an alarming rate. No single intervention can halt the rise of the obesity epidemic. Particular attention is given to exploring causative factors and preventive measures in early life, when biological determinants of risk trajectories, feeding behaviour and dietary preferences are shaped. Some lifestyle and nutrition modifications in pregnancy and infancy can reduce subsequent obesity risk. Also postnatal infant gut colonisation may modify later obesity risk, but currently available evidence does not allow firm conclusions. Surprisingly, about 3.2 times more systematic reviews (SR) than randomized clinical trials (RCTs) were published on "probiotics" and health, and even 7.9 times more SR than RCTs on "probiotics" and obesity, which is not helpful. Multiple research opportunities exist for exploring the early origins of obesity to contribute towards halting the rise in obesity prevalence. Exploring the early development of the microbiome in its complexity, its dependence on dietary and other exogenous factors, and its metabolic and regulatory functions is promising. Meaningful progress for obesity prevention can most likely be achieved by combining several strategies.

  15. INVENTORY IN POLAND - CURRENT SITUATION AND PROSPECTS

    Directory of Open Access Journals (Sweden)

    O. Kemp

    2017-02-01

    ESTATE otdelnuyu for a fee. Inventory tesno svjazana with systemoy zemelnыh reestrov / ypotekoy. Ymeyte in mind, something cadastre That was the main thing tselju Introduction tax. Therefore on rehystryruet realnoe tekuschye STATUS (for example: at present aktualnoe Using Time zemelnыh plots, current availability sobstvennyka REAL ESTATE (for example, naslednyk, kotoryya not Finished zakonnыe protsedurы pravopreemstva or How THIS neobhodyma info nachyslenyya for payment. Kadastrovыy 3D. At the level of research provodytsya the Scientific Search of opportunities for the creation of 3D-cadastre. Inventory in Poland ymeet davnye traditions. In many techenye desyatyletyy, yzmenylys hosudarstvennыe regimes and topics yzmenylsya Together with inventory and ego role in the economy of the state. At present pervychnoyzadachey cadastre TIME REAL ESTATE - creation of a system of tax collection from REAL ESTATE - javljaetsja vtorostepennыm task. WARNING Prynymaya t Volume sobrannoy of information, .ee pravdopodobnost and accuracy, and First Total globality, the main thing remains Relevance role dannoy information. The inventory constantly razvyvaetsya. Poland, on vedetsya in digital forms and is believed Samoa Large data base REAL ESTATE. THIS data base constantly menyaetsya. Some IZ potentsyalnыh already Modified hotovы for Implementation (The cost of property tax on Some partially voshly (3D cadastre as part nekotoraya everything else before a Stage issledovatel`skoe work (mnohotselevoy inventory.

  16. Educational Research in Mainland China: Current Situation and Developmental Trends

    Science.gov (United States)

    Sun, Miantao

    2011-01-01

    The influence of Confucian culture in Chinese Mainland China is reflected in the current situation and contextual trends of educational research content of educational thought of Confucianism, educational issues grounded on theoretical views of Confucianism, and the influence of the inclusiveness of Confucianism. In terms of research method, the…

  17. Current job situation of the alumni from IBS Groningen -2017

    NARCIS (Netherlands)

    Liefers, Jan

    2017-01-01

    Our main question is: what is the current job situation of the alumni from IBS Groningen? The sub questions are: •How many students graduated in the various years? •What are the most popular jobs? •Where do alumni work and what is the career path? •What is their highest degree? •What companies

  18. The earth's ring current - Present situation and future thrusts

    Science.gov (United States)

    Williams, D. J.

    1987-01-01

    Particle distributions, currents, and the ring current situation prior to the August 1984 launch of the AMPTE Charge Composition Explorer (CCE) are discussed. CCE results which demonstrate the capability of these new measurements to pursue questions of ring current sources, energization, and transport are presented. Consideration is given to various ring current generation mechanisms which have been discussed in the literature, and a two-step generation process which to a certain extent unifies the previous mechanisms is presented. The first in-situ global observations of ring current decay as obtained through the detection of energetic neutral atoms generated by charge exchange interactions between the ring current and hydrogen geocorona are discussed, as well as the possibility of using the detection of energetic neutral atoms to obtain global images of the earth's ring current.

  19. An overview of current situations of robot industry development

    Directory of Open Access Journals (Sweden)

    Wu Qiong

    2018-01-01

    Full Text Available As an industry of emerging technology, robot industry has become one of important signs to evaluate a country’s level in science and technology innovation and high-end manufacturing, and an important strategic field to take the preemptive opportunities in development of intelligent society. Developed countries such as the USA, Germany, France and Japan have formulated their robot R&D strategies and planning in succession. China boasts good industrial foundation and has made encouraging progress in the course of development of robot technology. This paper briefly discusses the application type of robot industry and current situations of robot industry development in countries around the world, and makes detailed explanation of current situations of robot industry development in China.

  20. Current situation by product advertising on the czech market

    OpenAIRE

    Jitka Červencová

    1998-01-01

    Advertising represents for producers the least expensive admission to an ample market and it enables to consumers to orient at the market. All advertising means serve to intensifying of the product sale or image of firm. The article describes current situation in the area of exquisite instruments of advertising and next a firm's deciding if it hires an advertising agency or if carries out advertising on their own - what advantages and risks result from the cooperation of the firm and the agen...

  1. ULTRAHIGH ENERGY COSMIC RAYS: REVIEW OF THE CURRENT SITUATION

    Directory of Open Access Journals (Sweden)

    Todor Stanev

    2013-12-01

    Full Text Available We describe the current situation of the data on the highest energy particles in the Universe – the ultrahigh energy cosmic rays. The new results in the field come from the Telescope Array experiment in Utah, U.S.A. For this reason we concentrate on the results from these experiments and compare them to the measurements of the other two recent experiments, the High Resolution Fly’sEye and the Southern Auger Observatory.

  2. Waste management in Greenland: current situation and challenges

    DEFF Research Database (Denmark)

    Eisted, Rasmus; Christensen, Thomas Højlund

    2011-01-01

    Waste management in Greenland (56 000 inhabitants) is characterized by landfilling, incineration and export to Denmark of small quantities of metals and hazardous waste. The annual amount of waste is estimated to about 50 000 tons but actual data are scarce. Data on the waste composition is basic...... are small and equipped with only moderate flue gas cleaning technology. This report summarizes the current waste management situation in Greenland and identifies important challenges in improving the waste management....... is basically lacking. The scattered small towns and settlements, the climate and the long transport distances between towns and also to recycling industries abroad constitute a complex situation with respect to waste management. The landfills have no collection of gas and leachate and the incinerators...

  3. The current situation and future prospects of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Ando, Atsushi

    2001-01-01

    Radiopharmaceuticals play an important role in nuclear medicine. In this paper, nuclear medicine relating to radiopharmaceuticals was briefly described. And I would like to focus on the current situation and future prospects of radiopharmaceuticals. Nuclear medicine in this century should take the following directions. Firstly, cancer treatment by radionuclides will be one of the promising fields in oncology. Secondly, in order to achieve evidence-based medicine, sensitive, quantitative imaging using the nuclides will be necessary in nuclear medicine. Under these circumstances, it is important to develop radiopharmaceuticals for sensitive, quantitative imaging and therapeutic radiopharmaceuticals. (author)

  4. Current situation of wind energy in the world and Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Alper Kaplan, Yusuf; San, Ismail [Department of Electrical and Electronics Engineering, Anadolu University (Turkey)], email: yakaplan@anadolu.edu.tr, email: isan@anadolu.edu.tr

    2011-07-01

    This paper gives an overview of the current situation of wind power in Turkey and in the world by evaluating installed wind power using current data. It also looks at the political conditions of Turkey in relation to the current installed wind energy power in Turkey compared with that of certain developed countries. The problems encountered are also illustrated as a basis for proposing solutions. Turkey's wind energy potential is 48,000 MW but installed wind power was only 1,329 MW as of 2011. Wind energy is at present one of the most cost-competitive renewable energy technologies in the world when technical, geographical and social issues are taken into consideration. Economic sources should be researched. The development of current potential and the market entry of renewable energy resources requires a legal and regulatory framework that support suitable mechanisms. Local support is recommended together with tax exemptions. Long-term fixed-price guarantees should also be considered by government.

  5. Legal assessment of current situation on orphan patients in Lithuania.

    Science.gov (United States)

    Spokiene, Indre

    2008-01-01

    After Lithuania joined the European Union, the Regulation (EC) No. 141/2000 on orphan medicinal products and Commission Regulation (EC) No. 847/2000 came into force as part of national legislation. Member States must adopt specific measures to increase knowledge on rare diseases and to improve their detection, diagnosis, and treatment. The aim of this article was to present and to assess the current legal situation on orphan patients and their treatment in Lithuania, to identify legislation gaps, and to propose some ideas how to facilitate the solution of the existing problems in this field. For this purpose, European Union and Lithuanian legal documents on rare medicinal products are examined using a comparative method. With reference to inventory of Member States' incentives for rare diseases in national level, the most important issues, which orphan patients face to in Lithuania, are singled out. In Lithuania, the situation of orphan patients in terms of protection of patient rights is insufficiently determined. The access to effective health care services or approved therapies in some cases is restricted. Working relationships between genetic services and various clinical specialists as well as with those in primary care are not legally determined; the number of clinical trials aimed at orphan medicinal products is low. These results suggest a need for awareness raising among Lithuanian Government, health care specialists, patient organizations about the importance to improve practical implementation of European Union legislation and progressive experience of some European countries in this field.

  6. [First-aid in France. Current situation and future perspectives].

    Science.gov (United States)

    Larcan, Alain; Julien, Henri

    2010-06-01

    First-aid--treatment aimed at enabling a victim to survive pending the arrival of qualified medical support--is less well developed in France than in many other industrialized countries, especially among the general public. The current status of first-aid in France is paradoxical: schooling is free and obligatory, the ambulance service and emergency services are of the highest quality, but the general public are too often passive and unknowledgeable when faced with an emergency situation. This situation is due to several factors, including the complexity of first-aid training and regulations, the involvement of too many public bodies, the legal liability of the first-aider, and a lack of ongoing training. The French National Academy of Medicine recommends 8 measures to improve this situation: Provide a legal definition of first-aid: "a set of recognized measures aimed, in an emergency setting, at preserving the physical and psychological integrity of the victim of an accident or illness, notably pending the arrival of professional medical assistance". Waive, as in many other countries, civil and legal responsibility for the non professional first-aider, except in case of clear negligence. Reinforce the organization of first-aid in France in order to monitor the number and quality of first-aiders, and to ensure theoretical and pedagogic research; create a communications department capable of supporting and promoting first-aid. Improve access to first-aid training by increasing the number of situations in which it is obligatory (driving tuition, school and university examinations, group responsibility, at-risk practices), by providing financial assistance for certain groups, and by ensuring routine training at school, in the armed forces, and in the workplace. Create a progressive and integrated citizen first-aid training course with individual modules, ensuring that first-aiders update and perfect their knowledge throughout life. Soften pedagogic rules and shorten

  7. [Development and current situation of reconstruction methods following total sacrectomy].

    Science.gov (United States)

    Huang, Siyi; Ji, Tao; Guo, Wei

    2018-05-01

    To review the development of the reconstruction methods following total sacrectomy, and to provide reference for finding a better reconstruction method following total sacrectomy. The case reports and biomechanical and finite element studies of reconstruction following total sacrectomy at home and abroad were searched. Development and current situation were summarized. After developing for nearly 30 years, great progress has been made in the reconstruction concept and fixation techniques. The fixation methods can be summarized as the following three strategies: spinopelvic fixation (SPF), posterior pelvic ring fixation (PPRF), and anterior spinal column fixation (ASCF). SPF has undergone technical progress from intrapelvic rod and hook constructs to pedicle and iliac screw-rod systems. PPRF and ASCF could improve the stability of the reconstruction system. Reconstruction following total sacrectomy remains a challenge. Reconstruction combining SPF, PPRF, and ASCF is the developmental direction to achieve mechanical stability. How to gain biological fixation to improve the long-term stability is an urgent problem to be solved.

  8. Current situation of RI's and radiation utilization in Japan

    International Nuclear Information System (INIS)

    1976-01-01

    Usage of RIs and radiation is now extensive, for the improvement of industrial production techniques and also in medicine and agriculture. The current situation in Japan is described as follows: enterprises using RIs, circulation of RIs, the equipments provided with RIs in private enterprises, commercial RI, and radiation utilization, expenditures and sales related to RIs and radiation in mining and industries, and personnel. The number of places using RIs and radiation totaled about 3,200 (in 1975). The expenditures for RIs and radiation in private enterprises are about 17,500 million yen while sales are 20,800 million yen (both in fiscal 1974). The total number of personnel engaged in RI and radiation works is about 62,000. (Mori, K.)

  9. Current situation and countermeasures of port logistics park information construction

    Directory of Open Access Journals (Sweden)

    Zhen Liu

    2013-03-01

    Full Text Available Purpose: Improve work efficiency of logistics park department, and drive the economy of the park and its surrounding areas. Design/methodology/approach: Analyze the information development situation and existent questions of current national logistics park, and design proper scheme to meet the demand of port logistics park. Findings: Proposed an information construction implementation plan using technology of the Internet of things which can be applied to port logistics park. Designed a scheme for the park information construction and explained the system's implementation strategy and implementation steps. Practical implications: The proposed construction program is particularly suitable for the northwest port logistics parks in China, and also has reference function to other logistics park construction. Originality/value: Group the information construction of the logistics park into four levels, three types of users, and two requirements. The scheme is innovative and comprehensive, which can ensure the development of port logistics park.

  10. Global panorama of energy access: Current situation, challenges and outlook

    Energy Technology Data Exchange (ETDEWEB)

    Galichon, Ines; Lacroix, Olivier; Wiedmer, Damien

    2014-07-15

    Globally 1.3 billion people do not have access to electricity. If this figure is projected to decline 1 billion by 2030, the global population who relies on the traditional use of biomass for cooking is expected to substantially increase, from 2.6 billion to 2.7 billion people. In its commitment to energy access, ENEA published a synthesis on the current situation and the further development perspectives of energy access worldwide, a crucial issue of human and economic development and an opportunity for the private sector. This synthesis present the ecosystem of the actors involved in the improvement of energy access and the technical solutions that serve the needs of this high-potential market. The five main challenges energy access has to address are presented in this publication: energy prices, equipment financing, distribution, change of scale and environmental performances.

  11. The Japanese energy sector: Current situation, and future paths

    International Nuclear Information System (INIS)

    Takase, Kae; Suzuki, Tatsujiro

    2011-01-01

    As the world's third leading economy and a major importer of fuels, the choice of future energy paths and policies that Japan makes in the next few years will have a significant influence on the energy security of the world as a whole, and of the Northeast Asia region in particular. In this article we describe the current status of and recent trends in the Japanese energy sector, including energy demand and supply by fuel and by sector. We then discuss the current energy policy situation in Japan, focusing on policies related to climate change targets, renewable energy development and deployment, liberalization of energy markets, and the evolution of the Japanese nuclear power sector. The final section of the article presents the structure of the Japan LEAP (long-range energy alternatives planning software system) dataset, describes several alternative energy paths for Japan - with an emphasis on alternative paths for nuclear power development and GHG emission abatement - and touches upon key current issues of energy policy facing Japan, as reflected in the modeling inputs and results.

  12. The Japanese energy sector: Current situation, and future paths

    Energy Technology Data Exchange (ETDEWEB)

    Takase, Kae, E-mail: kae@gdl.jp [Governance Design Laboratory, Inc., 2301 City Tower Bashamichi 5-71 Onoe-cho, Naka-ku, Yokohama, Kanagawa 231-0015 (Japan); Suzuki, Tatsujiro [University of Tokyo, Graduate School of Public Policy, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0081 (Japan)

    2011-11-15

    As the world's third leading economy and a major importer of fuels, the choice of future energy paths and policies that Japan makes in the next few years will have a significant influence on the energy security of the world as a whole, and of the Northeast Asia region in particular. In this article we describe the current status of and recent trends in the Japanese energy sector, including energy demand and supply by fuel and by sector. We then discuss the current energy policy situation in Japan, focusing on policies related to climate change targets, renewable energy development and deployment, liberalization of energy markets, and the evolution of the Japanese nuclear power sector. The final section of the article presents the structure of the Japan LEAP (long-range energy alternatives planning software system) dataset, describes several alternative energy paths for Japan - with an emphasis on alternative paths for nuclear power development and GHG emission abatement - and touches upon key current issues of energy policy facing Japan, as reflected in the modeling inputs and results.

  13. [Social and health resources in Catalonia. Current situation].

    Science.gov (United States)

    Bullich-Marín, Ingrid; Sánchez-Ferrín, Pau; Cabanes-Duran, Concepció; Salvà-Casanovas, Antoni

    The network of social and health care has advanced since its inception. Furthermore, news services have been created and some resources have been adapted within the framework of respective health plans. This article presents the current situation of the different social and health resources in Catalonia, as well as the main changes that have occurred in recent years, more specifically in the period of the Health Plan 2011-2015. This period is characterised by an adaptation of the social and health network within the context of chronic care, for which the development of intermediate care resources has become the most relevant aspect. There is also a need to create a single long-term care sector in which the health care quality is guaranteed. Moreover, in this period, integral and cross-care level is promoted in the health system through a greater coordination between all different levels of care. The social and health network, due to its trajectory and expertise, plays a key role in the quality of care for people with social and medical needs. Copyright © 2017 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Current Situation of Leprosy in India and its Future Implications.

    Science.gov (United States)

    Rao, P Narasimha; Suneetha, Sujai

    2018-01-01

    The global leprosy situation has changed significantly over the last four decades after the introduction of multidrug therapy (MDT) in 1982 with a reduction in prevalence from over 5 million cases in the mid-1980s to less than 200,000 at the end of 2016. The programme in India also saw a reduction from a prevalence rate of 57.8/10,000 in 1983 to less than 1/10,000 by the end of 2005 when India declared to have reached the World Health Organization (WHO) target of elimination as a public health problem. Post 2005, major changes in the programme were made by the National leprosy eradication programme (NLEP) and the global leprosy programme, which may have affected the new case detection (NCD), disability, and child leprosy trends, which continue to show no appreciable regression. This article reviews the current global and Indian leprosy scenario to bring out its achievements and successes, including the impact of Leprosy Case Detection Campaigns (LCDC) on leprosy numbers. The basis and expected benefits of recent introduction of chemo and immune-prophylaxis in the programme are also discussed. It also discusses the shortcomings, the areas of concern, and the need for an inclusive strategy in the Indian leprosy programme that includes an intersectoral collaboration within the country for reaching the desired goal of leprosy eradication.

  15. Current situation and future usage of anticancer drug databases.

    Science.gov (United States)

    Wang, Hongzhi; Yin, Yuanyuan; Wang, Peiqi; Xiong, Chenyu; Huang, Lingyu; Li, Sijia; Li, Xinyi; Fu, Leilei

    2016-07-01

    Cancer is a deadly disease with increasing incidence and mortality rates and affects the life quality of millions of people per year. The past 15 years have witnessed the rapid development of targeted therapy for cancer treatment, with numerous anticancer drugs, drug targets and related gene mutations been identified. The demand for better anticancer drugs and the advances in database technologies have propelled the development of databases related to anticancer drugs. These databases provide systematic collections of integrative information either directly on anticancer drugs or on a specific type of anticancer drugs with their own emphases on different aspects, such as drug-target interactions, the relationship between mutations in drug targets and drug resistance/sensitivity, drug-drug interactions, natural products with anticancer activity, anticancer peptides, synthetic lethality pairs and histone deacetylase inhibitors. We focus on a holistic view of the current situation and future usage of databases related to anticancer drugs and further discuss their strengths and weaknesses, in the hope of facilitating the discovery of new anticancer drugs with better clinical outcomes.

  16. Current Situations and Countermeasures of Organic Tobacco Development

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Current situations of organic tobacco development at both home and abroad,indicating that organic tobacco is one of the innovation directions for sustainable,healthy,environmental protection and low carbon development of modern tobacco industry.On the basis of foreign cultivation technical system for organic agriculture,the cultivation technical system for organic tobacco is summed up as follows:first,keep the diversity and continuity of space and time;second,ensure closeness of nutrient cycle;third,improve self-regulatory system and protection ability of crops.Then,the development trend of organic tobacco is analyzed and corresponding measures are put forward:establish production base and assessment system for organic tobacco;establish technical system for production of organic tobacco;establish and perfect evaluation system for management,production and supervision of organic tobacco;strengthen popularization of production and concept of organic tobacco;improve management of organic tobacco purchase,industry commerce handover,and redrying.

  17. Current Situation in Vocational Schools: Issues and Some Suggested Solutions

    Directory of Open Access Journals (Sweden)

    Reha Metin ALKAN

    2014-12-01

    Full Text Available Vocational Schools which have undertaken various missions throughout history were established in order to train intermediate staff s with suff icient knowledge and skills in their fields, in accordance with the requirements of trade, industry and services sectors and they are the most important components of ‘vocational and technical education system' today. Analyzing the education given in the vocational schools in accordance with the national and international requirements, developing technologies and the needs of business world and making the necessary arrangements in line with these will contribute to the employability and preferability of graduates of these schools in an eff icient way. Many industrialists/businessmen in our country stated that they experienced serious problems in the supply of qualified staff with suff icient knowledge and skills needed in sectors. Although much progress has been achieved in this subject, it is a fact that there are still a lot of work to be done. In this study, current situation and main troubles in vocational schools are discussed in the light of the experiences gained at Hitit University Vocational School which was established about 40 years ago in Çorum and which is one of the first high schools in Turkey and some solutions are suggested in accordance with the problems mentioned.

  18. The Current Situation of Wind Energy in Turkey

    Directory of Open Access Journals (Sweden)

    Raşit Ata

    2013-01-01

    Full Text Available Wind energy applications and turbine installations at different scales have increased since the beginning of this century. As wind energy is an alternative clean energy source compared to the fossil fuels that pollute the atmosphere, systems that convert wind energy to electricity have developed rapidly. Turkey’s domestic fossil fuel resources are extremely limited. In addition, Turkey’s geographical location has several advantages for extensive use of wind power. In this context, renewable energy resources appear to be one of the most efficient and effective solutions for sustainable energy development and environmental pollution prevention in Turkey. Among the renewable sources, Turkey has very high wind energy potential. According to the Organization for Economic Cooperation and Development (OECD Turkey theoretically has 166 TWh a year of wind potential. However the installed wind power capacity is approximately 14% of total economical wind potential. In this study, Turkey’s installed electric power capacity and electric energy production are investigated and also the current situation of wind energy in Turkey is examined. The wind data used in this study were taken from Turkish Wind Energy Association (TUREB for the year 2012. This paper reviews the assessment of wind energy in Turkey as of the end of July 2012 including wind energy applications.

  19. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... sex for most patients represents only a moderate stress on the heart. Proposed Strategy Sex is a common concern, but most sexual activity ... all of your efforts, there are times when stress like this cannot be handled by ... patients should not engage in sex. Even if you feel you are not physically ...

  1. Questions to Ask Your Doctor--Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... family member or I still drive, travel, have sex, work out or continue other activities we enjoy? How ... in Children • Arrhythmia Tools & Resources Answers by Heart Fact Sheets Learn and live with our downloadable patient ...

  2. How to Respond to an Implantable Cardioverter-Defibrillator Recall

    Science.gov (United States)

    ... managing your emotions appropriately and being proactive. Behavioral Management Plan Your best plan of action is to ... recall for all patients. The recall of 1 brand of ICD does not mean that there is ...

  3. [Full dental rehabilitation of a patient with implantable cardioverter defibrillator].

    Science.gov (United States)

    Imre, Ildikó; Tóth, Zsuzsanna

    2012-06-01

    During dental rehabilitation of a patient with ICD, an upper telescope retained overdenture with acrylic baseplate and lower cantilever bridges were constructed. In the consultation following the anamnesis and the clinical examination, the cardiologist did not believe antibiotic profilaxis to be necessary, adding that it is advisable to avoid the use of ultrasonic depurator and electrocauter. Nowadays after saving the life the improving of patient's better quality of life is an important aspect. The risk of ICD-implantation is minimal however, not negligible, the patient can pursue a way of life free of limitation. According to the latest trends, the number of ICD-implantations will increase exponentially in the near future, due to the aging of the population, the simplification and safeness of implantation and the increase of patients who can be treated with the device. In case of arritmia or putative dysfunction, the latest ICD-s are able to send emergency alert to the arritmia centre with the help of an outer transmitter. Probably the system will completely change the follow-up of patients with ICD within the next few years, clinical researches of its efficiency are going on at present.

  4. Implantable cardioverter defibrillator does not cure the heart.

    Science.gov (United States)

    Sławuta, Agnieszka; Boczar, Krzysztof; Ząbek, Andrzej; Gajek, Jacek; Lelakowski, Jacek; Vijayaraman, Pugazhendhi; Małecka, Barbara

    2018-01-23

    A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.

  5. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...... questions regarding the experience of phantom shocks, date, time, and place. Twelve patients (9.4%) experienced a phantom shock, 7 in the intervention group and 5 in the control group (NS). Neither age, sex, quality of life nor perceived health at baseline was significantly related to the probability...

  6. The current situation for gastric cancer in Chile.

    Science.gov (United States)

    Caglevic, Christian; Silva, Shirley; Mahave, Mauricio; Rolfo, Christian; Gallardo, Jorge

    2016-01-01

    Gastric cancer is a neoplasm with a high incidence and mortality rate in Chile where more than 3000 people die every year from this type of cancer. This study shows the clinical and epidemiological considerations of this disease, information about translational research on this pathology in Chile, the contribution of Chilean doctors to the development of gastric cancer management awareness and the general situation of gastric cancer in Chile.

  7. Current experimental situation in heavy-ion reactions

    International Nuclear Information System (INIS)

    Scott, D.K.

    1978-06-01

    A detailed survey of the present experimental situation in heavy-ion physics is presented. The discussion begins by considering the simple excitation of discrete states in elastic scattering, transfer, and compound-nucleus reactions; it then turns to more drastic perturbations of the nucleus high in the continuum through fusion, fission, and deeply inelastic scattering, and concludes with the (possibly) limiting asymptotic phenomena of relativistic heavy-ion collisions. 138 figures, 5 tables, 451 references

  8. Current situation of women in the workplace in Chile

    OpenAIRE

    Cábová, Helena

    2016-01-01

    This diploma thesis examines the problem of the situation of women in the workplace in Chile. The thesis is divided into three parts, while each parts gradually analyses the problem of gender inequalities. Firstly, the thesis presents the overall information about the general problem of gender inequalities. It introduces the basic fragments of the issue together with the basic terminology. Secondly, a major focus is put on the Chilean regions, as it analyses gender differences of the regions ...

  9. [Current situation with abortion in Colombia: between illegality and reality].

    Science.gov (United States)

    González Vélez, Ana Cristina

    2005-01-01

    This article discusses the illegality of abortion in Colombia, situating this country within the 0.4% of the world population where abortion is completely banned. Absolute criminalization of abortion turns it into a public health matter and produces social inequality. The Colombian legislation has always disregarded women as individuals and as persons in full possession of their legal rights. In contrast to a comprehensive conceptualization of sexual and reproductive rights, the various abortion bills merely refer either to "morally unacceptable" situations such as pregnancy resulting from rape or to therapeutic motives. Contradictions between illegality and reality give rise to a public discourse that features rejection of abortion practices, in keeping with the prevailing stance of the ecclesiastic hierarchy, while in practice, and at the private level, people resort to voluntary interruption of pregnancy under conditions of safety and confidentiality, at least for women from the higher socioeconomic strata. This situation not only causes social inequality but also reflects how laws lose meaning and create the collective impression of being useless or unnecessary, thus undermining the state's governing role.

  10. The Current Situation of Female Scientists in Argentina

    Science.gov (United States)

    Llois, Ana María; Dawson, Silvina Ponce

    2009-04-01

    We report the changes that have taken place recently regarding the situation of female scientists in Argentina. We comment on the rules for maternity leave that have been passed recently for research scholars doing their PhDs and on the number of women scientists that occupy decision making-positions in science. We also present some evidence that seems to indicate that, among young scientists, women are more willing to occupy leadership positions and that the Argentinean society is more accepting of this new role.

  11. Current Situation of Highway Daily Maintenance Management in Beijing

    Directory of Open Access Journals (Sweden)

    Pan Feng Ming

    2016-01-01

    Full Text Available Combined with the industry property, characteristics and management needs of highway maintenance project in Beijing, through investigation and research of the highway daily maintenance management, the present situation of highway repair and maintenance is expounded from the aspects such as the determination of maintenance funds and plan, maintenance management mode, and so on. Then in order to explore the new mechanisms for market management of highway maintenance, the advantages and disadvantages of highway maintenance and minor repairment of Beijing are analyzed.

  12. Current situation and discussion of acquisition work in professional libraries

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping

    2010-01-01

    The acquisition work in professional libraries is an important part of library work, and faces enormous challenges at this stage. For the status quo of the acquisition work in professional libraries, we should develop effective acquisition principles to ensure the integrity of our professional library's collection and systematic literature, and to provide more effective protection for relevant research work. We need reasonable arrangements for the procurement of books with limited funding to avoid the waste of funds. We should use the network, to actively develop the procurement channels, and to establish accurate and reliable systematic network of information resources for the reader. We need to consciously cultivate and improve the professional competence of acquisition staff, to meet the requirement of the acquisition staff in the new situation. We should carry out knowledge management in professional library, to form a competitive 'knowledge resources'. For information research, technical personnel, and scientific researchers, we provide effective information services in time, and carry out personalized services. (authors)

  13. Current environmental situation in the new Federal States. Pt. 1

    International Nuclear Information System (INIS)

    Haury, H.J.; Koller, U.; Assmann, G.

    1992-01-01

    'Information on Environment' organised the first part of a seminar for jounalists on the present environmental situation in the now federal states in Berlin on the 3rd and 4th of December. More than 50 participants from radios, TV, daily and special press attended this ninth event of 'Information on Environment' in Berlin. Leading scientists from research institutes of the former GDR, the Federal Environmental Agency and the GSF-research centre for environment and heath gave papers on the predominant environmental problems in the new federal states. This first part deals with water pollution, waste water treatment, drinking water supply, environmental problems of lignite mining, radiation pollution in the Erzgebirge; forest damage research and special armament wastes and waste problems in general. (orig.) [de

  14. Tianshuishi space breeding current situation and developing trend

    International Nuclear Information System (INIS)

    Wang Fuquan; Song Jianrong; Zhang Zhongping; Guo Zhenfang

    2012-01-01

    Tianshuishi is located in Xi'an to lanzhou among two big cities, the five space launch, has vegetables, food, grasses, flowers, rape, melon and fruit, Chinese traditional medicine, amount of 8 categories of crops, such as the 22 new material after carrying the ground breeding work. Only vegetables on identified 23 aerospace new varieties. After ten years of space breeding, summarizes the present situation of Tianshuishi space breeding, development experience, characteristic, trends, and puts forward the development space breeding Tianshuishi organization and breeding of talent from the matching policy and grow up incentive mechanism, strengthen the cooperation and all over the country, establishing fiscal policy support from the aspects such as advice. (authors)

  15. [Current situation and existing problems of acupuncture for primary hypertension].

    Science.gov (United States)

    Zhang, Lili; Wei, Pengfei; Chen, Shaozong

    2018-03-12

    To analyze the present situation and existing problems of acupuncture for primary hypertension (PH) based on clinical research literature in recent 20 years. The clinical research literature regarding acupuncture for PH were searched from China National Knowledge Infrastructure (CNKI), VIP data network (VIP) and Wanfang database from 1997 through 2016; a total of 218 papers met the inclusive criteria. Microsoft Excel and Apriori algorithm of SPSS Clementine software were applied to analyze the data. The main acupoints of acupuncture for PH were Taichong (LR 3), Quchi (LI 11), Zusanli (ST 36) and Hegu (LI 4), but its support degree was only 12.21%. 127 papers were randomized controlled trials, accounting for 58.26%. 158 papers had clear diagnostic criteria, accounting for 72.48%. 138 papers had clear efficacy evaluation criteria, accounting for 63.30%. Only 5.05% of the papers were classified as high-quality literature by using Jadad scale. In recent 20 years, some rules existed in acupoint selection for PH, but the support degree was low so it could not accurately guide clinical treatment. Although the clinical literature quality of acupuncture for PH was gradually increasing, the proportion of high-quality literature was low, therefore modern medical research model and foreign similar research should be followed to design a more rigorous trial protocol. As a result, the quality of clinical research is increased to provide reference for future clinical treatment.

  16. [Harm reduction interventions in drug users: current situation and recommendations].

    Science.gov (United States)

    Bosque-Prous, Marina; Brugal, María Teresa

    2016-11-01

    Harm reduction encompasses interventions, programmes and policies that seek to reduce the negative consequences of the consumption of both legal and illegal drugs on the individual and public health. Harm reduction looks to mitigate the harm suffered by drug users through drug use monitoring and prevention, and promotes initiatives that respect and protect the human rights of this population. The harm reduction policies that have proven effective and efficient are: opioid substitution maintenance therapy (methadone); needle and syringe exchange programmes; supervised drug consumption rooms; and overdose prevention through peer-based naloxone distribution. In order to be effective, these policies must have comprehensive coverage and be implemented in areas where the target population is prevalent. Resident-based opposition to the implementation of these policies is known as the NIMBY (Not In My Back Yard) phenomenon, which is characterised by being against the implementation of new measures in a particular place, but does not question their usefulness. Given that any NIMBY phenomenon is a complex social, cultural and political phenomenon, it is important to conduct a thorough analysis of the situation prior to implementing any of these measures. Harm reduction policies must be extended to other substances such as alcohol and tobacco, as well as to other conditions beyond infectious/contagious diseases and overdose. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. The presence of contaminations in sewage sludge - The current situation.

    Science.gov (United States)

    Fijalkowski, Krzysztof; Rorat, Agnieszka; Grobelak, Anna; Kacprzak, Malgorzata J

    2017-12-01

    Sewage sludge/biosolids are by-wastes of municipal and industrial wastewater treatment. As sources of nutrients (C, N, P) they are widely used in intensive farming where large supplementation of organic matter to maintain fertility and enhance crop yields is needed. However, according to the report of European Commission published in 2010, only 39% of produced sewage sludge is recycled into agriculture in the European Union. This situation occurs mainly due to the fact, that the sewage sludge may contain a dangerous volume of different contaminants. For over decades, a great deal of attention has been focused on total concentration of few heavy metals and pathogenic bacteria Salmonella and Escherichia coli. The Sewage Sludge Directive (86/278/EEC) regulates the allowable limits of Zn, Cu, Ni, Pb, Cd, Cr and Hg and pathogens and allows for recovery of sludge on land under defined sanitary and environmentally sound conditions. In this paper, a review on quality of sewage sludge based on the publications after 2010 has been presented. Nowadays there are several papers focusing on new serious threats to human health and ecosystem occurring in sewage sludge - both chemicals (such as toxic trace elements - Se, Ag, Ti; nanoparticles; polyaromatic hydrocarbons; polychlorinated biphenyl; perfluorinated surfactants, polycyclic musks, siloxanes, pesticides, phenols, sweeteners, personal care products, pharmaceuticals, benzotriazoles) and biological traits (Legionella, Yersinia, Escherichia coli O157:H7). Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Research on current situations of geriatric nursing education

    Directory of Open Access Journals (Sweden)

    Liu Yujin

    2017-01-01

    Full Text Available The population aging is accelerating and the aging population is growing in China. Although the geriatric nursing education has been developed for more than 20 years, geriatric nursing professionals are still insufficient and the geriatric nursing education is facing various challenges under the new situation. This paper primarily describes the developmental history and the related concepts of geriatric nursing education, and analyzes the personnel training modes and routes of geriatric nursing education, and its problems, in order to provide the basis for the reform of geriatric nursing education. The development of geriatric nursing needs a large number of outstanding nursing personnel, and the cultivation of geriatric nursing professionals depends on the development of geriatric nursing and the improvement of the teaching quality of geriatric nursing education. Front-line educators working on geriatric nursing should be committed to reforming the geriatric nursing teaching, improving the teaching quality and cultivating the high-quality nursing personnel suitable for conditions of the elderly in China.

  19. [Current situation of the most frequent zoonosis in the world].

    Science.gov (United States)

    Flores Castro, Ricardo

    2010-01-01

    Zoonoses are at the present time more important than ever due to their magnitude and impact. The international trade in animals, products and sub products, as well as the intense travel of people around the world, represent risks of dissemination of infectious diseases, and are the reason for a new age of emerging and reemerging zoonotic diseases. Under these conditions, public health and animal health authorities are obliged to work together in order to get more efficient control programs. In this paper the actual situation of some important emerging and reemerging zoonoses is analyzed, including: anthrax, rabies, tuberculosis, brucellosis, cysticercosis, echinococcosis, hanta virus, Hendra and Nipah virus. Particular attention is given to leptospirosis, due to the fact that it is considered by WHO and OIE as the widest spread zoonotic disease in the world. Zoonoses caused by ingestion of animal food products are discussed. They are responsible for the death of almost 2.2 million people. Bacteria of genus salmonella and campylobacter are considered. Some recommendations are given for the control and prevention of zoonoses, emphasizing the "One Health" concept.

  20. Dental laboratory technology education in China: current situation and challenges.

    Science.gov (United States)

    Zheng, Liwei; Yue, Li; Zhou, Min; Yu, Haiyang

    2013-03-01

    Modern dentistry and dental education in China were first introduced from abroad by Dr. Lindsay in 1907. However, advancements in the field of dental laboratory technology did not occur to the same degree in specialties such as prosthodontics and orthodontics. Since the 1990s, orders from abroad demanding dental appliances surged as the image of China as the "world's factory" strengthened. The assembly line model, in which technicians work like simple procedure workers, was rapidly applied to denture production, while the traditional education system and apprenticeship systems demonstrated little progress in these years. The lack of advancement in dental laboratory technology education caused insufficient development in China's dental technology industry. In order to alter the situation, a four-year dental laboratory technology undergraduate educational program was established in 2005 by West China School of Stomatology, Sichuan University (WCSS, SCU). This program was based on SCU's undergraduate education and WCSS's junior college education systems. The program introduced scientific methods in relevant subjects into laboratory technicians' training and made many improvements in the availability of trained faculty, textbooks, laboratory facilities, and curriculum.

  1. AACSB Accreditation in China--Current Situation, Problems, and Solutions

    Science.gov (United States)

    Zhang, Xinrui; Gao, Yan

    2012-01-01

    This paper first introduces the background of the AACSB (Association to Advance Collegiate Schools of Business) accreditation, and then analyzes the current status of the participation of Chinese business schools in AACSB accreditation. Based on the data analysis, the paper points out that there are two main problems in the Chinese business…

  2. Naked singularities and cosmic censorship: comment on the current situation

    International Nuclear Information System (INIS)

    Seifert, H.J.

    1979-01-01

    The current discussion is mainly concerned with how, or indeed, whether space-times possessing naked singularities can be ruled out as being too unrealistic or not being singular at all. The present position is summarized, with references, under the following headings: the Hawking-Penrose existence theorems, hydrodynamical singularities and the strength of naked singularities. (UK)

  3. [Current malaria situation in the Republic of Kazakhstan].

    Science.gov (United States)

    Bismil'din, F B; Shapieva, Zh Zh; Anpilova, E N

    2001-01-01

    The Republic of Kazakhstan is situated in the northern hemisphere on the boundary of two continents--Europe and Asia--at a longitude of 45 degrees E--87 degrees E and a latitude of 40 degrees N--55 degrees N. The total area of the republic is 2,724,900 square kilometers. Kazakhstan shares a border with the Russian Federation to the north-west, north and east: the border between the two countries is almost 6500 km long. To the south, Kazakhstan shares a border with the Central Asian states of Turkmenistan (380 km), Uzbekistan (2300 km) and Kyrgystan (980 km). To the south-east, it shares a border with China (1460 km): to the west is the Caspian Sea (600 km). Thus, the total length of Kazakhstan's external borders is 12,000 km. Because of the geographical, natural and climatic features prevailing throughout most of the Republic, there is a potential danger that local transmission of malaria may begin again if the disease is imported from abroad. The areas most at risk are the Panfilov and Uigur raions of Almaty oblast, which share a border with malaria-endemic regions of China, and the Saryagash and Makhtaral' raions of South Kazakhstan oblast along the border with Uzbekistan. The Government of the Republic of Kazakhstan places particular emphasis on malaria prevention and control, taking into account the historical data about the prevalence of malaria from the late 1920s to the early 1940s, amounting to hundreds of thousands of cases every year. Government Decree No. 840 entitled "Urgent Measures to Protect the Population from Blood-Sucking Insects and Ticks Dangerous to Humans", which lays down measures for the control of malarial mosquitoes in the areas most susceptible to malaria resurgence, was adopted in 1996. The Ministry of Health of the Republic of Kazakhstan issued instructions in 1998 and 1999 which were designed to motivate all health facilities in the field of malaria prevention and control. At present, as part of the directives developed by the

  4. ORIGIN, HISTORY AND CURRENT SITUATION OF PELIBUEY SHEEP IN MEXICO

    Directory of Open Access Journals (Sweden)

    Cecilio Ubaldo Aguilar Martínez

    2017-12-01

    Full Text Available Domestic sheep (Ovis aries is descendant from Asian mouflon and was domesticated in the Near East. Later, sheep began its dissemination to West Africa, where it is believed that the ancestry of Pelibuey sheep came from. Pelibuey sheep were brought to America by the Spaniards to feed the crew of the boats. It is unclear whether these animals came directly from West Africa or from the Canary Islands. It is considered that Pelibuey sheep entered to Mexico between 1930 and 1940, although some authors think that this breed already existed in the country in the late nineteenth century. Since 1963, Pelibuey sheep has been the most studied breed in Mexico, due to its ability to produce in tropics, as well as its high adaptability to most agro-ecological zones of the country. A brief review about productive and reproductive traits in current Pelibuey herds, allowed to conclude that they are very similar to those of the first sheep studied almost 50 years ago. Currently, the breed has been subjected to  non-planned crosses with other breeds to increase productivity, which puts in risk this important genetic resource. Therefore, there is a need to realize the conservation of the breed.

  5. KPMU projects. Current environmental situation and expected developments

    International Nuclear Information System (INIS)

    Ribarska, T.

    2010-01-01

    The following KPMU projects are described: Dry storage facility, which will allow the dry storage of 5256 fuel assemblies, currently stored in the spent fuel ponds of reactors of Units 3,4 and the WSF; Projects for equipment and activities related to management of liquid RAW which is already have being implemented on the site and are therefore covered in the current KNPP EIA; Ion Exchange Resin retrieval and Conditioning Equipment; Plasma melting facility; Facility for Retrieval and Processing of The Solidified Phase from Evaporator Concentrate Tanks; Control of Liquid and Gaseous Releases for the Units under Decommissioning at KNPP; Size Reduction and Decontamination Active Workshop –Design, Construction and Equipment Supply and Installation; Supply of: dismantling, size reduction and decontamination tools and equipment; Infrastructure and security perimeter separation; Heat generation plant; EIA for Decommissioning of units 1 to 4; Decay Storage Site for Transitional RAW; Site for Conventional Waste from Decommissioning; Inventory, Treatment and Conditioning of Contaminated Soils; Waste Backlog Treatment

  6. The current situation of treatment systems for alcoholism in Korea.

    Science.gov (United States)

    Kim, Jee Wook; Lee, Boung Chul; Kang, Tae-Cheon; Choi, Ihn-Geun

    2013-02-01

    Alcoholism is becoming one of the most serious issues in Korea. The purpose of this review article was to understand the present status of the treatment system for alcoholism in Korea compared to the United States and to suggest its developmental direction in Korea. Current modalities of alcoholism treatment in Korea including withdrawal treatment, pharmacotherapy, and psychosocial treatment are available according to Korean evidence-based treatment guidelines. Benzodiazepines and supportive care including vitamin and nutritional support are mainly used to treat alcohol withdrawal in Korea. Naltrexone and acamprosate are the drugs of first choice to treat chronic alcoholism. Psychosocial treatment methods such as individual psychotherapy, group psychotherapy, family therapy, cognitive behavior therapy, cue exposure therapy, 12-step facilitation therapy, self-help group therapy, and community-based treatment have been carried out to treat chronic alcoholism in Korea. However, current alcohol treatment system in Korea is not integrative compared to that in the United States. To establish the treatment system, it is important to set up an independent governmental administration on alcohol abuse, to secure experts on alcoholism, and to conduct outpatient alcoholism treatment programs and facilities in an open system including some form of continuing care.

  7. Yemen in a Time of Cholera: Current Situation and Challenges.

    Science.gov (United States)

    Al-Mekhlafi, Hesham M

    2018-03-19

    Since early 2015, Yemen has been in the throes of a grueling civil war, which has devastated the health system and public services, and created one of the world's worst humanitarian disasters. The country is currently facing a cholera epidemic the world's largest on record, surpassing one million (1,061,548) suspected cases, with 2,373 related deaths since October 2016. Cases were first confirmed in Sana'a city and then spread to almost all governorates except Socotra Island. Continued efforts are being made by the World Health Organization and international partners to contain the epidemic through improving water, sanitation and hygiene, setting up diarrhea treatment centers, and improving the population's awareness about the disease. The provision of clean water and adequate sanitation is imperative as an effective long-term solution to prevent the further spread of this epidemic. Cholera vaccination campaigns should also be conducted as a preventive measure.

  8. Nuclear energy: current situation and prospects to 2020.

    Science.gov (United States)

    Ion, Sue

    2007-04-15

    For close to half a century nuclear fission has been providing reliable supplies of electricity to the UK, with virtually no emissions of carbon dioxide. Over that period, the UK nuclear industry has avoided the emission of over one and a half billion tonnes of CO2. Yet no nuclear plant has been built in the UK for over two decades even though many of the stations in our current fleet are now within a decade or so of the end of their lifetime. Without new plants being ordered soon, the UK's nuclear capacity will decline dramatically, from 23% today to 3% post-2020--just as considerations of supply security and climate change are becoming increasingly important. Elsewhere in the world, many countries such as China, India, Japan, South Korea, Finland and France are building new stations. Other countries such as the USA, South Africa, and some nations that currently do not have nuclear stations (such as Indonesia and Poland) are making preparations for future nuclear stations. Globally capacity factors for nuclear plants are higher than they have ever been, averaging around 85% and with the best stations achieving well over 90%. Lifetime can be 60 years. That the economics of such stations compete well with other technologies is well founded and easily verifiable--especially in the face of rising fossil fuel prices and the pricing in of costs for CO2 emissions--both of which stand to improve the economics of nuclear energy still further. Waste volumes arising from modern plants are just a fraction of those of some earlier stations, and the technologies are in place to deal with them safely and effectively. Following recent reviews and international developments, there is growing confidence that internationally available competitive designs of nuclear plant will provide part of the solution to the UK's long-term energy needs.

  9. Anti-Angiogenics: Current Situation and Future Perspectives.

    Science.gov (United States)

    Zirlik, Katja; Duyster, Justus

    2018-01-01

    Angiogenesis, the process leading to the formation of new blood vessels, is one of the hallmarks of cancer. Extensive studies established that i) vascular endothelial growth factor (VEGF) is a key driver of sprouting angiogenesis, ii) VEGF is overexpressed in most solid cancers, and iii) inhibition of VEGF can suppress tumor growth in animal models. This has led to the development of pharmacological agents for anti-angiogenesis to disrupt the vascular supply and starve the tumor of nutrients and oxygen, primarily through the blockade of VEGF/VEGF receptor signaling. This effort has resulted in 11 anti-VEGF drugs approved for certain advanced cancers, either alone or in combination with chemotherapy and other targeted therapies. However, inhibition of VEGF signaling is not effective in all cancers, and anti-angiogenics have often only limited impact on overall survival of cancer patients. This review focuses on the current status of FDA-approved anti-angiogenic antibodies and tyrosine kinase inhibitors and summarizes the progress and future directions of VEGF-targeted therapy. © 2018 S. Karger GmbH, Freiburg.

  10. Promotion of breastfeeding in Poland: the current situation.

    Science.gov (United States)

    Królak-Olejnik, Barbara; Błasiak, Ilona; Szczygieł, Anna

    2017-12-01

    Objective Exclusive breastfeeding is safe and beneficial for healthy infants; it is the optimal feeding method during the first 6 months of life. Infants should be complementary fed in conjunction with breastfeeding until 12 months of age or longer. The aim of the present study was to analyse the duration of breastfeeding through 12 months of age. Methods Participants were 1679 women from 42 randomly selected hospitals in Poland. The data were obtained from surveys, including a paper and pencil interview that was conducted after mothers delivered in the hospital and before discharge. Computer aided telephone interviews were administered at 2, 4, 6 and 12 months. Results There was a high rate of initiating breastfeeding after birth (97%), a rapid abandonment of exclusive breastfeeding (43.5% at 2 months, 28.9% at 4 months and 4% at 6 months) and an onset of formula feeding during the first days of life, which is contrary to current recommendations. Conclusions It is necessary re-educate mothers, medical staff who care for mothers and children during the perinatal period, and other specialists.

  11. Energy Consumption of Lactating Mothers: Current Situation and Problems

    Directory of Open Access Journals (Sweden)

    Sandra Fikawati

    2014-08-01

    Full Text Available Recommendations on the adequacy of nutrient intake indicate that lactating mothers have higher nutritional needs than do pregnant mothers. High nutrient intake is necessary to help mothers recover after childbirth, produce milk, and maintain the quantity and quality of breast milk. It also prevents maternal malnutrition. Research has shown, however, that the dietary energy consumption of mothers during lactation was significantly lower than that during pregnancy. The current study explored the factors associated with decreased nutritional intake during maternal lactation. The study was conducted in March–April 2013, and the subjects were mothers with infants aged >6 months. Results revealed that the factors causing low dietary energy consumption among breastfeeding mothers were poor nutritional knowledge and attitude toward high energy intake requirements during lactation, lack of time to cook and eat because of infant care, reduced consumption of milk and supplements, dietary restrictions and prohibitions, and suboptimal advice from midwives/health personnel. Beginning from the antenatal care visit, health personnel should conduct effective counseling on the importance of nutrient intake during lactation. Advice should be provided not only to mothers, but also to their families to enable them to thoroughly support the mothers as they breastfeed their infants.

  12. Management of anaphylaxis in Latin America: current situation

    Directory of Open Access Journals (Sweden)

    Victoria Cardona

    2017-06-01

    Full Text Available Background: Anaphylaxis is a systemic and severe allergic reaction, which can be fatal. The first-line treatment of choice, according to international guidelines, is intramuscular adrenaline. However, different studies show that the performance of health professionals managing anaphylaxis is often inadequate Objective: To assess the current resources available in Latin American countries for the diagnosis and treatment of anaphylaxis. Methods: Online survey promoted by the Latin American Society of Allergy and Immunology to representatives of the national allergy societies of Latin American countries. Results: Responses were received from 10 countries out of the 14 countries invited to participate. Only five of the countries have clinical practice guidelines in anaphylaxis. Adrenaline autoinjectors are available only in two countries, Argentina and Brazil, but are not subsidized by public health systems. In all countries, adrenaline is available in ampoules, which is the presentation usually prescribed to patients for self-administration. The use of adrenaline was estimated to be less than 50 % of cases in five countries, while antihistamines and corticosteroids are almost always used. The determination of serum tryptase is possible in some health centers, often private, in five of the countries surveyed. Conclusion: It is necessary to improve resources related to the diagnosis and management of anaphylaxis in Latin American countries.

  13. The current situation of uranium mining in Hungary

    International Nuclear Information System (INIS)

    Erdi-Krausz, G.

    1997-01-01

    The paper describes the history of uranium production in Hungary. It focuses on the Mecsek Ore Mining Company, now known as Mecsekuran Limited, and its relationship with the Hungarian Government. From the start of uranium production in 1963 until May 1989 all production was exported to the Soviet Union under a bilateral contract. In exchange the Soviet Union agreed to provide fabricated fuel for the future Hungarian nuclear power plant. In May 1989 the Government of Hungary announced closure of its uranium mining operations because of the high cost of production. The paper describes the history of events since 1989, as well as the current plans to terminate all uranium production by 31 December 1997. The Mecsek Mountains lie in the southern part of Hungary, west from the Danube, about 30 km from the former Yugoslavian border, and north from the city of Pecs. Its eastern side is built up from medieval limestone and dolomites, while the western part is from sandstone and clay from the geological Paleozoic. In the eastern part high quality cokeable coal has been mined for more than 200 years, east from the city of Pecs; and in the western part uranium ore was discovered and the mining began only a few decades ago. (author)

  14. Current situation and future prospects for the Australian beef industry.

    Science.gov (United States)

    Greenwood, Paul Leo; Ferguson, Drewe M

    2018-04-12

    Beef production extends over almost half of Australia, with about 47,000 cattle producers that contribute about 20% ($A12.7 billion GVP) of the total value of farm production in Australia. Australia is one of the world's most efficient producers of cattle and was the world's third largest beef exporter in 2016. The Australian beef industry had 25 million head of cattle in 2016-17, with a national beef breeding herd of 11.5 million head. Australian beef production includes pasture based cow-calf systems, a backgrounding or grow-out period on pasture, and feedlot or pasture finishing. Feedlot finishing has assumed more importance in recent years to assure the eating quality of beef entering the relatively small Australian domestic market, and to enhance the supply of higher value beef for export markets. Maintenance of Australia's preferred status as a quality assured supplier of high value beef produced under environmentally sustainable systems from 'disease-free' cattle is of highest importance. Stringent livestock and meat quality regulations and quality assurance systems, and productivity growth and efficiency across the supply chain to ensure price competiveness, are crucial for continued export market growth in the face of increasing competition. Major industry issues, that also represent research, development and adoption priorities and opportunities for the Australian beef industry have been captured within exhaustive strategic planning processes by the red meat and beef industries. At the broadest level, these issues include consumer and industry support, market growth and diversification, supply chain efficiency, productivity and profitability, environmental sustainability, and animal health and welfare. This review provides an overview of the Australian beef industry including current market trends and future prospects, and major issues and opportunities for the continued growth, development and profitability of the industry.

  15. Aerial wildfire fighting: history, current situation, problems and perspectives

    Directory of Open Access Journals (Sweden)

    A. V. Bryukhanov

    2017-10-01

    Full Text Available Nowadays aviation is among the most effective ways of early detection and suppression of wildfires. At the moment for the aerial wildfire fighting a few dozen models of aircraft are used worldwide, which are regularly modernized and renewed. In this article, authors give information about the history of fighting wildfires from the air, as well as analyze the current state of the issue with the use of aircraft and helicopter airtankers for firefighting, both at international level and in the territory of the Russian Federation. It is revealed that the most popular in the world still are the ground-based firefighting aircraft (regardless of the class of the carrying capacity. Amphibious firefighting aircraft now exist only in light (carrying capacity up to 5 tons and in medium type (capacity up to 15 tons. Among the helicopter aviation, heavy firefighting helicopters are mostly widely spread, as well as medium multipurpose helicopters, which are, apart from suppression, involved into delivery of people and goods to forest fire sites. The article is devoted to the main directions, according to which the development of aircraft tanker equipment abroad and in Russia occurs. The attention is directed to the most promising developments, and specific recommendations on how to increase the effectiveness of the fire aviation usage in Russia are given. Based on the studies carried out, a conclusion is drawn that for different countries there can be promising different types of firefighting aircraft, considering their landing field infrastructure, characteristics of forests and hydro systems, as well as the total area of the forest fund.

  16. Evolving PBPK applications in regulatory risk assessment: current situation and future goals

    Science.gov (United States)

    The presentation includes current applications of PBPK modeling in regulatory risk assessment and discussions on conflicts between assuring consistency with experimental data in current situation and the desire for animal-free model development.

  17. Current Situations and Countermeasures of Development of Kiwifruit Industry in Guizhou Province

    OpenAIRE

    Huang, Wei; Wan, Ming-chang; Yang, Sheng-jun; Zhang, Xue; Qiao, Rong

    2012-01-01

    On the basis of current development situations of planting, scientific research and processing of kiwifruit industry in Guizhou Province, the paper analyzes main factors restricting development of kiwifruit industry, including lack of unified planning, standardized planting specifications, and backward management of kiwifruit orchard. In accordance with current development situations and restricting factors, the paper presents some countermeasures for development of kiwifruit industry in Guiz...

  18. Energy infrastructure modeling for the oil sands industry: Current situation

    International Nuclear Information System (INIS)

    Lazzaroni, Edoardo Filippo; Elsholkami, Mohamed; Arbiv, Itai; Martelli, Emanuele; Elkamel, Ali; Fowler, Michael

    2016-01-01

    Highlights: • A simulation-based modelling of energy demands of oil sands operations is proposed. • Aspen simulations used to simulate delayed coking-based upgrading of bitumen. • The energy infrastructure is simulated using Aspen Plus achieving self-sufficiency. • Various scenarios affecting energy demand intensities are investigated. • Energy and CO_2 emission intensities of integrated SAGD/upgrading are estimated. - Abstract: In this study, the total energy requirements associated with the production of bitumen from oil sands and its upgrading to synthetic crude oil (SCO) are modeled and quantified. The production scheme considered is based on the commercially applied steam assisted gravity drainage (SAGD) for bitumen extraction and delayed coking for bitumen upgrading. In addition, the model quantifies the greenhouse gas (GHG) emissions associated with the production of energy required for these operations from technologies utilized in the currently existing oil sands energy infrastructure. The model is based on fundamental engineering principles, and Aspen HYSYS and Aspen Plus simulations. The energy demand results are expressed in terms of heat, power, hydrogen, and process fuel consumption rates for SAGD extraction and bitumen upgrading. Based on the model’s output, a range of overall energy and emission intensity factors are estimated for a bitumen production rate of 112,500 BPD (or 93,272 BPD of SCO), which were determined to be 262.5–368.5 MJ/GJ_S_C_O and 14.17–19.84 gCO_2/MJ_S_C_O, respectively. The results of the model indicate that the majority of GHG emissions are generated during SAGD extraction (up to 60% of total emissions) due to the combustion of natural gas for steam production, and the steam-to-oil ratio is a major parameter affecting total GHG emissions. The developed model can be utilized as a tool to predict the energy demand requirements for integrated SAGD/upgrading projects under different operating conditions, and

  19. [Current Situation and Prospects of Emergency Medical Equipment in Our Country].

    Science.gov (United States)

    Qi, Lijing; Cheng, Feng

    2016-03-01

    This article analyzes the new demand of emergency medical equipment in the current development trend based on the analysis of the development and current situation of emergency medicine in our country. At the same time it introduces the current industrial characteristics of our country. Finally it analyzes the development trend of this kind of equipment in the new emergency medicine field.

  20. Analysis of the world epidemiological situation among vancomycin-resistant Enterococcus faecium infections and the current situation in Poland

    Science.gov (United States)

    Talaga-Ćwiertnia, Katarzyna; Bulanda, Małgorzata

    2018-01-01

    Vancomycin-resistant Enterococcus faecium (VREfm) strains have become an important hospital pathogen due to their rapid spread, high mortality rate associated with infections and limited therapeutic options. Vancomycin resistance is predominantly mediated by VanA or VanB phenotypes, which differ as regards maintaining sensitivity to teicoplanin in the VanB phenotype. The majority of VREfm cases in the United States, Europe, Korea, South America and Africa are currently caused by the VanA phenotype. However, the epidemics in Australia and Singapore are chiefly brought about by the VanB phenotype. The rate of VREfm isolate spread varies greatly. The greatest percentage of VREfm is now recorded in the USA, Ireland and Australia. Supervision of VRE is implemented to varying degrees. Therefore, the epidemiological situation in some countries is difficult to assess due to limited data or lack thereof.

  1. Current situation and prospect of market on the latest radiation measuring instrument

    International Nuclear Information System (INIS)

    Ha, Chang Ho; Kim, Wang Geum; Cho, Gyu Seong

    2009-12-01

    This book deals with current situation and prospect of market on the latest radiation measuring instrument. The contents of this book are basic of technology on radiation measuring instrument with basic principle of various measuring instrument, current situation of technology and prospect of radiation measuring instrument, effect of spreading and application field of radiation measuring instrument, facility for making and research and development of radiation measuring instrument, prospect of market about radiation measuring instrument, strategy for market entry with the latest radiation measuring instrument and general prospect for the future.

  2. Macrophytes in the lower Ebro and exploitation of Asco NPP. Current situation

    International Nuclear Information System (INIS)

    Munte Clua, L.; Esparza Martin, J. L.

    2012-01-01

    The objective of this stage is to expose the information obtained during the last decade and to present the current situation of the river, the implications involved for the operation of the plant, the solutions adopted in the short term and the results obtained so as proposals that the Administration must respond.

  3. The current legal situation relating to food irradiation as assessed by the Land Government

    International Nuclear Information System (INIS)

    Frede, W.

    1994-01-01

    Discussed is the current legal situation of food irradiation procedures as assessed by the Government of Northrhine-Westfalia. The topics highest on the agenda are the unrestrained exchange of merchandise within the Internal Market and the problems arising from deviating legal stipulations in the individual EU member states. (vhe) [de

  4. The Main Features of and Response to The Current Asian Security Situation

    Institute of Scientific and Technical Information of China (English)

    Hu; Shisheng

    2015-01-01

    I.The Main Features of the Current Asian Security Situation The strategic game between China and the United States becomes the most powerful driving force to change the Asian traditional security situation.The United States has tried its best to delay China’s rising pace or"to standardize"China’s rising path by using its huge military advantage and forward military deployment and strengthening its security network of alliance and friends,so as to maintain its dominant position in

  5. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  6. Current Situation and Developing Countermeasures of Postgraduate Innovation Center in China

    Directory of Open Access Journals (Sweden)

    Li Can

    2017-01-01

    Full Text Available Innovation is the driving force to promote the development of our nation. Postgraduate education, as an important approach to cultivate high-level talents, is a major part of the national innovation system. The establishment of the Postgraduate Innovation Center has an important significance for the cultivation of innovative talents in colleges and universities. This paper expounds the connotation and characteristics of Postgraduate Innovation Center and analyzes its current situation, operation mode, function orientation, institution settings and the innovative products. The paper also points out the problems in the current situation of the Postgraduate Innovation Center and finds the factors which restrict the development of the center. Finally, the paper puts forward some corresponding countermeasures.

  7. [Current situation of the standardization of acupuncture and moxibustion in Taiwan].

    Science.gov (United States)

    Pan, Li-Jia; Cui, Rui; Zhan, Bi-Yu; Liao, Cai-Yan; Cao, Qi-Hua; Li, Gui-Lan; Guo, Yi

    2012-09-01

    The current situation of the standardization of acupuncture and moxibustion in the Taiwan region is introduced in this paper from the three aspects, named the development state of standard of acupuncture and moxibustion in Taiwan, the implementation of Taiwan district standard and the standardization of acupuncture and moxibustion in Taiwan. At present, the relevant standards of acupuncture and moxibustion in Taiwan just include the standard operation procedure of acupuncture and moxibustion, the reference guideline of the safe operation in the medical service centers of traditional Chinese medicine, and the faculty standard of Chinese medicine hospital, etc. It is concluded that the current situation of the standardization of acupuncture and moxibusiton presented the weak awareness of the standardization of acupuncture and moxibustion in the industry, insufficient enterprise standard, less-quantity of the implemented standards and narrow coverage.

  8. The Role Of The Media In The Political Culture Of Russia: The Current Situation

    OpenAIRE

    Анна Леонидовна Кочурова

    2014-01-01

    The article is devoted to the analysis of the characteristics and activities of mass media as an institution of political culture, which should be aimed at raising citizens' awareness and capacity objective to organize information exchange between Government and citizens. Considered social acuteness and urgency of this problem, the main functions of the MASS MEDIA, a trend increase in the role and impact of the MEDIA on the current political situation in Russia.

  9. Esophageal stent implantation for the treatment of esophageal strictures: its current situation and research progress

    International Nuclear Information System (INIS)

    Zhu Haidong; Guo Jinhe; Teng Gaojun

    2011-01-01

    Esophageal stent implantation has been the most common therapy for the treatment of malignant and benign esophageal stenosis. At present, this technique is widely used in treating advanced esophageal cancerous stricture, refractory esophageal benign stricture and all kinds of esophageal fistulae or perforation. This paper aims to make a comprehensive review of the current situation and research progress of the esophageal stent implantation in clinical practice. (authors)

  10. Traditional Medicine in Madagascar - Current Situation and the Institutional Context of Promotion

    OpenAIRE

    C. Pierlovisi; L. Pourchez

    2014-01-01

    Following WHO recommandations and in order to improve medical coverage, Madagascar officially recognized in 2007 its traditional medicine as a legitimate practice.UNESCO, to sustain traditional healers in the Indian Ocean, wanted to use anthropological tools to explore the current situation in Madagascar.Despit a plurality of practices, data collected for three months in the Southeast of the Island, allowed us to identify some fundamental aspects of Malagasy traditional medicine, such as the ...

  11. Plagiarism: A Shared Responsibility of All, Current Situation, and Future Actions in Yemen.

    Science.gov (United States)

    Muthanna, Abdulghani

    2016-01-01

    As combating plagiarism is a shared responsibility of all, this article focuses on presenting the current situation of higher education in Yemen. The critical review of four implementable policy documents and interviews revealed the absence of research ethics code, research misconduct policy, and institutional policies in the country. This led to the presence of several acts of research dishonesty. The article concludes with an initiative for necessary future actions in the nation.

  12. The 1957 Valencia flood: hydrological and sedimentological reconstruction and comparison to the current situation

    Directory of Open Access Journals (Sweden)

    C. Puertes

    2016-10-01

    Full Text Available This work aims to improve the knowledge of the flood that took place in Valencia, Spain, in 1957. In other words, the aim is to test if it is possible to explain the flood waves with the incorporation of sediment cycle to a distributed hydrological model. Furthermore, this work aims to be aware of the current consequences of a similar event, taking into account land use changes, particularly, the urban rise in the lower basin, and the current flood defenses of the city. To do this, the hydrological model was implemented in the current basin situation. Once implemented, a reconstruction of precipitation at hourly discretization for the 1957 event was made and the sedimentological sub-model was calibrated. Then, the hydrographs in the chosen points were obtained. Finally, a simulation using the 1957 precipitation in the current basin situation was made, in order to be aware of the current consequences.

  13. [Current situation and thinking of diagnosis and treatment in some types of thyroid cancer].

    Science.gov (United States)

    Yang, X Y; Yu, Y; Li, D P; Dong, L

    2017-04-07

    As arising incidence of thyroid cancer, the treatment for thyroid carcinoma is becoming increasingly standardized. But there are different opinions on the treatment for some types of thyroid cancers, including the determination of operative opportunity, surgical method, and follow-up observation plan. There are mainly two categories of patients, namely the patients diagnosed as familial thyroid cancer mutation carriers through family screening, including medullary thyroid carcinoma and familial nonmedullary thyroid carcinoma, and the patients with thyroid microcarcinoma that can be observed after diagnosed by fine needle biopsy cytology. We will discuss current situation for the diagnosis and treatment of these patients.

  14. [Current situation on new psychoactive substances abuse among methadone maintenance treatment patients in China].

    Science.gov (United States)

    Cheng, Z; Dai, M M; Cao, X B

    2018-04-10

    Methadone maintenance treatment (MMT) greatly contributed to the successful outcomes of prevention and control on both AIDS and drug abuse in China. However, the features on drug abuse changed in the past decades, and the prevalence of new psychoactive substances abuse potentially somehow offset the achievement of MMT. This paper concised the information on research and surveys of this issue that targeting on the current situation, characteristics, related factors and relevant public health problem on new psychoactive substances abuse, among patients who have been on MMT, in China.

  15. Current situation of the project of 3. and 4. block of nuclear power plant Mochovce

    International Nuclear Information System (INIS)

    Suchy, L.

    2006-01-01

    The contribution shows the basic information about the crucial milestone of 3. building and the current situation of the project of 3. and 4. block of the nuclear power plant Mochovce. Contribution also shows what activities were realized and what material in area of designation of the technical and safety standard of the project was elaborated in the past, the main activities planned for 2006 have been described, support for Feasibility Study elaborated by ENEL and description of the integrated management system. The basic thesis crucial for the next steps on the project of 3. and 4. block of Nuclear Power Plant Mochovce is presented in the conclusion

  16. Implementation of systematic training approach in Kozloduy Training Centre - Current situation. Presentation of Bulgaria

    International Nuclear Information System (INIS)

    Kosturkov, L.

    1993-01-01

    To identify the needs in implementation of the systematic training approach, a relation between the number of trainees, duration of the training and the type of training should be made. In other hand, as it was stated in the TWG-T(93) Status Report, in order to be better identified outstanding training needs, the existing capabilities and other related projects should be taken into account. This report is pointed to give more details for the current situation in Bulgaria and to clarify the needs of international assistance. 3 refs, 3 tabs

  17. The current situation of waste management at German nuclear power plants

    International Nuclear Information System (INIS)

    Hottenrott, G.; Mirschinka, V.

    2002-01-01

    An overview is given about the main points of the agreement between the four utility companies and the German government on June 11, 2001, concerning waste management and disposal. The current waste management situation is compared with the effects of the agreement on the future development of the German waste management concept. Major innovations are the discontinuation of reprocessing, the establishment of local intermediate storage facilities for fuel elements and the suspension of the exploration works conducted on the salt dome at Gorleben. (orig.)

  18. [Current situation of toxicity classification of Chinese materia medica and its research thoughts].

    Science.gov (United States)

    Sun, Wenyan; Hou, Xiujuan; Wang, Bin; Zhu, Yuelan; Zhang, Shuofeng; Chang, Hongsheng; Sun, Jianning

    2012-08-01

    Toxicity of Chinese materia medica (CMM) is an important part of Chinese herbal nature theory. In clinical application, the dosage, time limitation and compatibility of CMM is mainly determined by toxicity. At present, there is no uniform toxicity classification standard for the evaluation of Chinese herbal toxicity. Therefore, it is significant to research toxicity classification of CMM. The current situation of toxicity classification of CMM is reviewed in this paper, and proposed research thoughts are as follows: the measurement of toxicity parameters, the confirmation of poisoning target organs, the investigation on toxic mechanism by serum pharmacology and toxicokinetics, the comprehensive evaluation on toxicity based on quantitative theory.

  19. [Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens].

    Science.gov (United States)

    Liu, Yungui; Yao, Ying; Shangguan, Shihao; Gu, Qun; Gao, Wuming; Chen, Yaoshui

    2014-05-01

    Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed. Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets. Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.

  20. Toward a more materialistic medicine: the value of authentic materialism within current and future medical practice.

    Science.gov (United States)

    Leder, Drew; Krucoff, Mitchell W

    2011-09-01

    Modern medicine is often accused by diverse critics of being "too materialistic" and therefore insufficiently holistic and effective. Yet, this critique can be misleading, dependent upon the ambiguous meanings of "materialism." The term can refer to the prevalence of financial concerns in driving medical practice. Alternatively, it can refer to "mechanistic materialism," the patient viewed as a body-machine. In each case, this article shows that this represents not authentic "materialism" at play, but a focus upon high-level abstractions. "Bottom-line" financial or diagnostic numbers can distract practitioners from the embodied needs of sick patients. In this sense, medical practice is not materialist enough. Through a series of clinical examples, this article explores how an authentic materialism would look in current and future practice. The article examines the use of prayer/comfort shawls at the bedside; hospitals and nursing homes redesigned as enriched healing environments; and a paradigmatic medical device--the implantable cardioverter defibrillator--as it might be presented to patients, in contrast to current practice.

  1. Cardiovascular magnetic resonance imaging in hypertrophic cardiomyopathy: Current state of the art.

    Science.gov (United States)

    Kamal, Muhammad Umar; Riaz, Irbaz Bin; Janardhanan, Rajesh

    2016-01-01

    Hypertrophic cardiomyopathy (HCM) is the most common genetic cardiomyopathy with a prevalence of 1:500 (0.2%) in the general population. Sudden cardiac death (SCD) is the most feared presentation of HCM. Therefore, it is essential to identify individuals at high risk in order to prevent SCD. The absence of conventional risk factors does not nullify the risk of HCM related SCD. Although echocardiography is currently the most widely used imaging modality, cardiac magnetic resonance (CMR) allows detailed characterization of the HCM phenotype, which makes it possible to differentiate HCM from other causes of left ventricular hypertrophy. CMR has the potential to further refine risk stratification. Late gadolinium enhancement (LGE) on CMR is a high-risk feature and there is emerging data to suggest that the presence of LGE should be employed as a marker for major adverse outcomes such as SCD, arrhythmias, systolic and diastolic heart failure. Hence, LGE on CMR may be considered an additional risk factor for SCD in HCM patients and should be incorporated in decision-making for implant-able cardioverter defibrillator implantation to aid primary prevention. Novel markers such as the extent of myocardial fibrosis on CMR must be accounted for comprehensive risk stratifica-tion of HCM patients. The purpose of this review is to discuss the current status and emerging role of CMR in HCM.

  2. Foot-and-mouth disease in pigs: current epidemiological situation and control methods.

    Science.gov (United States)

    León, Emilio A

    2012-03-01

    Foot-and-mouth disease (FMD) is the paradigm of a transboundary animal disease. Beyond any doubt, it is the most serious challenge for livestock's health. Official Veterinary Services from free countries invest considerable amount of money to prevent its introduction, whereas those from endemic countries invest most of their resources in the control of the disease. A very important volume of scientific production is developed every year in different aspects of FMD, and for that reason, the current knowledge makes the diagnosis of the disease easier to a great extent. However, FMD is still endemic in about two-thirds of the countries, and periodically re-emergent in several countries. This paper is a review of recent publications, focusing mainly on control measures and current world epidemiological situation, emphasizing primarily pigs. © 2012 Blackwell Verlag GmbH.

  3. Traditional Medicine in Madagascar - Current Situation and the Institutional Context of Promotion

    Directory of Open Access Journals (Sweden)

    C. Pierlovisi

    2014-12-01

    Full Text Available Following WHO recommandations and in order to improve medical coverage, Madagascar officially recognized in 2007 its traditional medicine as a legitimate practice.UNESCO, to sustain traditional healers in the Indian Ocean, wanted to use anthropological tools to explore the current situation in Madagascar.Despit a plurality of practices, data collected for three months in the Southeast of the Island, allowed us to identify some fundamental aspects of Malagasy traditional medicine, such as the omnipresence of symbolism or the complexity of healers’ roles at the crossroads of social, sacred and therapeutic registries.The study shows that the national policy on traditional medicine improves gradually the promotion of these practices too often undervalued. Nevertheless, the institutional context exposes weaknesses which might explain the difficulty encountered by some tradipractitioners to find their place in this new regulation. Indeed, regarding the current context, a reducing process of the healers' practices is likely to emerge.

  4. [Current situation of soil-transmitted nematodiasis monitoring in China and working keys in future].

    Science.gov (United States)

    Chen, Ying-dan; Zang, Wei

    2015-04-01

    Soil-transmitted nematodiasis is widely epidemic in rural areas in China. It was showed that the infection rate of soil-transmitted nematodes was 19.56% while the overall number of persons infected was 129,000,000, which was supported by the results of the National Survey of Current Situation of Major Human Parasitic Diseases in China in 2005 published by former Ministry of Health. Therefore, soil-transmitted nematodiasis was included in the national infectious diseases and pathogenic media monitoring system by Chinese Center for Disease Control and Prevention in 2006, and subsequently 22 monitoring spots were established nationwide. From 2006 to 2013, the human infection rate of intestinal nematodes in national monitoring spots decreased from 20.88% to 3.12%, which showed a declining trend year by year. Meanwhile, the infection rates of Ascaris lumbricoides, Trichuris trichiura, hookworm, Enterobius vermicularis decreased from 10.10%, 5.88%, 8.88%, 10.00% in 2006 to 0.76%, 0.42%, 2.04%, 6.78% in 2013 respectively. In this paper, the current situation of soil-transmitted nematodiasis is overviewed based on a summary of the 8 years' monitoring work, as well as the experiences, challenges and key of monitoring work in the future.

  5. Co-occurring Mental Disorders in Substance Abuse Treatment: the Current Health Care Situation in Germany.

    Science.gov (United States)

    Dauber, Hanna; Braun, Barbara; Pfeiffer-Gerschel, Tim; Kraus, Ludwig; Pogarell, Oliver

    2018-01-01

    Aim of this study was to investigate the current health care situation for patients with co-occurring mental disorders in addiction treatment. Therefore, data from the German Substance Abuse Treatment System ( N  = 194,406) was analysed with regard to the prevalence of comorbid mental disorders, treatment characteristics and outcomes of patients with comorbid psychiatric diagnosis. In outpatient setting, the prevalence of comorbid diagnoses was considerably lower (4.6%) than in inpatient setting (50.7%), but mood and anxiety disorders were the most prevalent additional diagnoses in both settings. In the treatment of patients with these comorbid disorders, we found higher rates of complementary internal and external (psychiatric) treatment, more co-operations and referrals after treatment, and positive treatment process outcomes. Findings indicate that the knowledge of an additional diagnosis influences the health care provision of affected patients and can therefore be seen as the essential precondition for providing adequate and comprehensive treatment. This highlights the importance of a sufficient consideration and diagnostic assessment of mental disorders in addiction treatment to further improve the health care situation of comorbid patients.

  6. Current situation and future plans in radioactive waste management in Mexico

    International Nuclear Information System (INIS)

    Lopez, H.; Jimenez, M.

    1992-01-01

    A brief introduction is offered in this document in order to explain the importance which is given in Mexico to the safe management of radioactive wastes. The Secretaria de Energia, Minas e Industria Paraestatal is the organization responsible for this issue. Also, a brief historical background is offered so as to understand the evolution of these activities since they were originated. This background allows us to describe the present situation, which consists in a substantial change in the volume of produced radioactive wastes; in other words, before the present situation only the, nuclear wastes from the application of radioisotopes were generated whereas currently, with the starting of commercial operation of the first unit of Laguna Verde Nuclear Power Plant (LVNPP), large volumes of industrial radioactive wastes are being generated. A mention is given as well of the acquired experience during more than 20 years of waste management and of the technologies which have been applied or practiced in the use and disposal of such wastes. Finally, some general trends in relation to the future planning are indicated, which essentially consist in the siting and characterization of a site so as to, design and construct a permanent disposal facility in order to dispose the operational radioactive wastes from LVNPP

  7. TUBERCULOSIS EPIDEMIC SITUATION IN THE CHECHEN REPUBLIC IN CURRENT SOCIAL AND ECONOMIC CONDITIONS

    Directory of Open Access Journals (Sweden)

    Vera Mikhailovna Alekseeva

    2017-05-01

    Full Text Available Introduction. Tuberculosis is one of the most important medical and social problems in the whole world as well as in Russia and its separate regions. Purpose. The study was aimed at assessment of tuberculosis epidemic situation in the Chechen Republic in the current socio-economic conditions after counterterrorist operations. Materials and methods. The authors analyzed the annual reports of the Ministry of Health of the Chechen Republic for 2010–2015, data of Rosstat, statistical data form for tuberculosis (№ 8 and № 30. Results. The results shown a threefold increase in the main tuberculosis indicators (incidence, prevalence and mortality after counterterrorist operations (1994–1996, and a decrease in these indicators in 2010–2015. The authors have found the cities and rural municipal districts with the most and the least favorable tuberculosis situation. The study results demonstrated an increase in the number of patients with bacillary, with fibrous-cavernous form, as well as patients with tuberculosis in combination with HIV infection. The authors proved the relation between the prevalence of fibrous-cavernous form of tuberculosis and mortality rate. Tuberculosis incidence in children (0–14 years and adolescents (15–17 years decreased in 2010–2015 while the incidence in adolescents remains higher than the incidence in children. Conclusion. Effective antituberculosis work in the Chechen Republic needs to improve the quality of medical examinations, early detection of tuberculosis, timely immunization, and health education.

  8. Current situation of H9N2 subtype avian influenza in China.

    Science.gov (United States)

    Gu, Min; Xu, Lijun; Wang, Xiaoquan; Liu, Xiufan

    2017-09-15

    In China, H9N2 subtype avian influenza outbreak is firstly reported in Guangdong province in 1992. Subsequently, the disease spreads into vast majority regions nationwide and has currently become endemic there. Over vicennial genetic evolution, the viral pathogenicity and transmissibility have showed an increasing trend as year goes by, posing serious threat to poultry industry. In addition, H9N2 has demonstrated significance to public health as it could not only directly infect mankind, but also donate partial or even whole cassette of internal genes to generate novel human-lethal reassortants like H5N1, H7N9, H10N8 and H5N6 viruses. In this review, we mainly focused on the epidemiological dynamics, biological characteristics, molecular phylogeny and vaccine strategy of H9N2 subtype avian influenza virus in China to present an overview of the situation of H9N2 in China.

  9. [Tracheal Intubation by Paramedics in a Local Community: Current Situation and Future Challenges].

    Science.gov (United States)

    Takinami, Yoshikazu

    2016-03-01

    As of April 2013, 164 paramedics are certified to perform tracheal intubation in Fukui Prefecture. This study investigated the current situation surrounding tracheal intubation performed by paramedics in prehospital care. Subjects were 58 paramedics who completed practical training at our hospital. Post-training duration, number of tracheal intubation cases, number of attempts before successful tracheal intubation, disease involved, rate of return of spontaneous circulation, and prognosis were examined. Tracheal intubation was successful on the first attempt in 92% of cases. Rate of return of spontaneous circulation was high in paramedics whose post-training duration was short. No return of spontaneous circulation occurred after a second attempt. Four patients survived asphyxia or aspiration. It is important to perform successful tracheal intubation on the first attempt, to recognize the probability of successful resuscitation in patients with exogenous disease, and to strengthen the medical control system.

  10. Heat supply from municipal solid waste incineration plants in Japan: Current situation and future challenges.

    Science.gov (United States)

    Tabata, Tomohiro; Tsai, Peii

    2016-02-01

    The use of waste-to-energy technology as part of a municipal solid waste management strategy could reduce the use of fossil fuels and contribute to prevention of global warming. In this study, we examined current heat and electricity production by incineration plants in Japan for external use. Herein, we discuss specific challenges to the promotion of heat utilisation and future municipal solid waste management strategies. We conducted a questionnaire survey to determine the actual conditions of heat production by incineration plants. From the survey results, information of about 498 incineration plants was extracted. When we investigated the relationship between heat production for external use and population density where incineration plants were located, we found that regions with a population density situation. © The Author(s) 2015.

  11. Analysis of current situation of information disclosure of listed companies on GEM

    Directory of Open Access Journals (Sweden)

    Zhirong Shen

    2017-03-01

    Full Text Available In the afternoon on October 23th, 2009, GEM was officially launched in our country. Due to the lack of experience in the market supervision, information disclosure violations frequently occurred. In April 2015, Shenzhen Stock Exchange puts forward morning information disclosure system to strengthen the reform of information disclosure system. Therefore, this paper deeply focuses on the current situation of information disclosure violations on GEM for the purpose of attracting more attention to the problems. Through studying the information disclosure violations of the listed companies on GEM from 2011 to September 30th, 2015, this paper divides the violations into the following four types: false record, misleading statement, material misstatement and delayed disclosure. On the other hand, we find that these types of violations are concurrent. From this discussion, we may safely draw the conclusion that the information disclosure of listed companies on GEM has the problem of untruthfulness, incorrectness, incompleteness and delay.

  12. The current situation and mid-term prospects for European electricity markets

    International Nuclear Information System (INIS)

    Helm, Dieter

    2013-01-01

    This analysis of the current situation and mid-term prospects for European electricity markets presents: the objectives of energy policy, the historical legacy, the attempts at European integration and the Internal Energy Market (IEM), the coming of the Climate Change Package, the impact of the world economic and Euro-zone crises, the impact of shale gas and the new world of fossil fuel abundance, the impact of renewables on emissions, the impact of renewables on electricity markets, the EU emissions trading system (EU ETS) and the renewables and the electricity markets, the coming of capacity crunch in some cases, the capacity markets, the return of central buyers and national energy policies, and what is to be done for the world electricity markets

  13. Current situation and development tendency of thermal spraying materials in China

    Institute of Scientific and Technical Information of China (English)

    YU; Yue-guang

    2005-01-01

    The current situations of thermal spraying materials in China are described in this paper.The thermal spraying technology in China has a great progress over tens of years. More than one hundred varieties of material products serve thermal spraying producing now. They belong to three kinds, powders,wires and rods. Technologies for producing alloy, ceramic and composite powders, alloy and cored wires,and oxide ceramic rods are applied to large-scale production. Many research and development works on advanced materials for thermal spraying are carrying out recent years. They show that the general tendencies of thermal spraying materials in China are composite or low-impurity component, ultrafine or nanosized microstructure, high properties, and specialized and systematized applications. Thermal spraying materials have great prospects with the development of saving society in China.

  14. Science communication in Brazil: A historical review and considerations about the current situation.

    Science.gov (United States)

    Massarani, Luisa; Moreira, Ildeu DE Castro

    2016-09-01

    In this paper, we present a historical overview of the science communication activities in Brazil since the nineteenth century and we analyze the current situation and its main concerns. The principal scopes and tools for science communication discussed here are the following: science centers and museums, mass media and large public events for communicating science and technology (S&T). In recent years, such activities have had a significant breakthrough in Brazil. Yet, there is still a long way to go in order to deliver a quality and extensive science and technology communication to the Brazilians as well as to achieve a suitable level of social appropriation of knowledge on S&T by the Brazilian society. Some of the main challenges that we are facing are discussed herein.

  15. Characteristics of gifted and talented student: the current situation in Portugal

    Directory of Open Access Journals (Sweden)

    Leandro Almeida

    2010-04-01

    Full Text Available This article presents the current situation in Portugal with regard to high capability and talented students, focusing on the authors’ experience in the National Association for Study and Intervention in Giftedness (ANEIS. In a sequential argument, we focus on the concept of giftedness, the most specific characteristics of high ability students, and the procedures used in their initial identification and assessment. Also, the most frequent educational responses to these students are described. Finally, we underline some studies conducted as a result of the collaboration between ANEIS and several Portuguese universities. These studies refer to the instruments and procedures used for the assessment of giftedness and talent, and the impact of the implemented educational measures.

  16. Biographical and Narrative Research in Iberoamerica: Areas of Development and Current Situation

    Directory of Open Access Journals (Sweden)

    Antonio Bolívar

    2006-09-01

    Full Text Available Currently, biographical-narrative inquiry has its identity within qualitative research, and it merits attention. This article reviews and describes the biographical-narrative research origin, development and variants in the social sciences of Iberoamerican countries. It offers a broad overview of this field of investigation, defining the main areas of narrative and (autobiographical inquiry. In this context, it is opted to do a synchronic and a diachronic approach to the current situation. It is based on development and experienced training in this field: 1 It offers a biographical-narrative research characterization about diverse and heterogeneous modalities, methodological variants, forms and dimensions 2 It highlights the roots and the reasons for the current relevance of this approach in social research in the Iberoamerican setting. 3 It describes the main questions and the approach progression, adopting a prospective point of view. 4 It describes the most relevant orientations, the most noteworthy instruments and the key characteristics that must be present in this type of investigation. URN: urn:nbn:de:0114-fqs0604125

  17. Preventing tomorrow's sudden cardiac death today: part I: Current data on risk stratification for sudden cardiac death.

    Science.gov (United States)

    Al-Khatib, Sana M; Sanders, Gillian D; Bigger, J Thomas; Buxton, Alfred E; Califf, Robert M; Carlson, Mark; Curtis, Anne; Curtis, Jeptha; Fain, Eric; Gersh, Bernard J; Gold, Michael R; Haghighi-Mood, Ali; Hammill, Stephen C; Healey, Jeff; Hlatky, Mark; Hohnloser, Stefan; Kim, Raymond J; Lee, Kerry; Mark, Daniel; Mianulli, Marcus; Mitchell, Brent; Prystowsky, Eric N; Smith, Joseph; Steinhaus, David; Zareba, Wojciech

    2007-06-01

    Accurate and timely prediction of sudden cardiac death (SCD) is a necessary prerequisite for effective prevention and therapy. Although the largest number of SCD events occurs in patients without overt heart disease, there are currently no tests that are of proven predictive value in this population. Efforts in risk stratification for SCD have focused primarily on predicting SCD in patients with known structural heart disease. Despite the ubiquity of tests that have been purported to predict SCD vulnerability in such patients, there is little consensus on which test, in addition to the left ventricular ejection fraction, should be used to determine which patients will benefit from an implantable cardioverter defibrillator. On July 20 and 21, 2006, a group of experts representing clinical cardiology, cardiac electrophysiology, biostatistics, economics, and health policy were joined by representatives of the US Food and Drug administration, Centers for Medicare Services, Agency for Health Research and Quality, the Heart Rhythm Society, and the device and pharmaceutical industry for a round table meeting to review current data on strategies of risk stratification for SCD, to explore methods to translate these strategies into practice and policy, and to identify areas that need to be addressed by future research studies. The meeting was organized by the Duke Center for the Prevention of SCD at the Duke Clinical Research Institute and was funded by industry participants. This article summarizes the presentations and discussions that occurred at that meeting.

  18. The Current Situation of Field Experience in a Five-Year Science Teacher Education Program in Thailand

    Science.gov (United States)

    Faikhamta, Chatree; Jantarakantee, Ekgapoom; Roadrangka, Vantipa

    2011-01-01

    This research explored the current situation in managing the field experience of a five-year science teacher education program in one university in Thailand. A number of methods were used to assess field experience situation: (1) a questionnaire on the perceptions of pre-service science teachers of field experience management; (2) participant…

  19. [Survey of current situation of schistosomiasis health education in Wuxi City].

    Science.gov (United States)

    Meng, Xiao-jun; Gao, Dong-lin; Zhang, Xuan; Lu, Bing

    2015-04-01

    To understand the current situation of schistosomiasis health education in in Wuxi City where schistosomiasis transmission has been interrupted, so as to provide the evidence for formulating the health education strategies. Face to face interviews and a professional designed questionnaire were used to collect the information of the current schistosomiasis health education and investigate the awareness of schistosomiasis knowledge in primary and middle schools and in communities. The total awareness rate of schistosomiasis knowledge was 87.7% among 873 students and the figure was 83.0% among 693 community residents. The students who studied in the schools with more than 1 class hour of schistosomiasis health education, completed schistosomiasis health education material or teaching plan, and implementing health education through multiple ways had higher knowledge awareness rates compared with the schools without (χ2 = 291.408, 709.622, 13.751, all P <0.001). The residents living in the communities with schistosomiasis health education through broadcast/TV or square propaganda had a higher knowledge awareness rate compared with the communities without (χ2= 90.772, 47.436, all P < 0.001). The awareness rates of schistosomiasis knowledge among both students and community residents in Wuxi City are low. Therefore, the schistosomiasis control health education should be strengthened.

  20. Current Situation of Treatment for Anaphylaxis in a Japanese Pediatric Emergency Center.

    Science.gov (United States)

    Ninchoji, Takeshi; Iwatani, Sota; Nishiyama, Masahiro; Kamiyoshi, Naohiro; Taniguchi-Ikeda, Mariko; Morisada, Naoya; Ishibashi, Kazuto; Iijima, Kazumoto; Ishida, Akihito; Morioka, Ichiro

    2018-04-01

    Anaphylaxis is a systemic allergic reaction that sometimes requires prompt treatment with intramuscular adrenaline. The aim of the study was to investigate the current situation regarding anaphylaxis treatment in a representative pediatric primary emergency facility in Japan. We retrospectively examined the medical records dating from April 2011 through March 2014 from Kobe Children's Primary Emergency Medical Center, where general pediatricians work on a part-time basis. Clinical characteristics and current treatments for patients with anaphylaxis who presented to the facility were investigated. Furthermore, we compared the clinical characteristics between anaphylaxis patients given intramuscular adrenaline and those not given it. During the study period, 217 patients were diagnosed with anaphylaxis. The median Sampson grade at the time of visit was 2, and 90 patients (41%) were grade 4 or higher. No patients received self-intramuscular injected adrenaline before arrival at our emergency medical center because none of the patients had been prescribed it. Further treatment during the visit was provided to 128 patients (59%), with only 17 (8%) receiving intramuscular adrenaline. Patients given intramuscular adrenaline had significantly lower peripheral saturation of oxygen at the visit (P = 0.025) and more frequent transfer to a referral hospital (P < 0.001) than those not given intramuscular adrenaline. Education for Japanese pediatric practitioners and patients is warranted, because no patients used self-intramuscular injected adrenaline as a prehospital treatment for anaphylaxis, and only severely affected patients who needed oxygen therapy or hospitalization received intramuscular adrenaline in a pediatric primary emergency setting.

  1. Geriatric oncology in Spain: survey results and analysis of the current situation.

    Science.gov (United States)

    Gironés, R; Morilla, I; Guillen-Ponce, C; Torregrosa, M D; Paredero, I; Bustamante, E; Del Barco, S; Soler, G; Losada, B; Visa, L; Llabrés, E; Fox, B; Firvida, J L; Blanco, R; Antonio, M; Aparisi, F; Pi-Figueras, M; Gonzalez-Flores, E; Molina-Garrido, M J; Saldaña, J

    2017-12-11

    Geriatric oncology (GO) is a discipline that focuses on the management of elderly patients with cancer. The Spanish Society of Medical Oncology (SEOM) created a Working group dedicated to geriatric oncology in February 2016. The main goal of this study was to describe the current situation in Spain regarding the management of elderly cancer patients through an online survey of medical oncologists. A descriptive survey was sent to several hospitals by means of the SEOM website. A personal e-mail was also sent to SEOM members. Between March 2016 and April 2017, 154 answers were collected. Only 74 centers (48%) had a geriatrics department and a mere 21 (14%) medical oncology departments had a person dedicated to GO. The vast majority (n = 135; 88%) had the perception that the number of elderly patients with cancer seen in clinical practice had increased. Eighteen (12%) oncologists had specific protocols and geriatric scales were used at 55 (31%) centers. Almost all (92%) claimed to apply special management practices using specific tools. There was agreement that GO afforded certain potential advantages. Finally, 99% of the oncologists surveyed believed it and that training in GO had to be improved. From the nationwide survey promoted by the Spanish Geriatric Oncology Working Group on behalf of SEOM, we conclude that there is currently no defined care structure for elderly cancer patients. There is an increasing perception of the need for training in GO. This survey reflects a reality in which specific needs are perceived.

  2. Cystic echinococcosis in Spain: current situation and relevance for other endemic areas in Europe.

    Directory of Open Access Journals (Sweden)

    Francisco A Rojo-Vazquez

    Full Text Available Cystic echinococcosis (CE remains an important health problem in many regions of the world, both where no control measures have been implemented, and where control programs have been incompletely successful with ensuing re-emergence of the disease. In Spain, official data on CE show an increase in the proportion of intermediate hosts with CE during the last few years, and autochthonous pediatric patients have been reported, a sign of active local transmission of disease. A similar picture emerges from data reported to the European Food Safety Authority by other European countries. Nevertheless, several crucial aspects related to CE that would help better understand and control the disease have not been tackled appropriately, in particular the emergence of infection in specific geographical areas. In this respect, while some data are missing, other data are conflicting because they come from different databases. We review the current situation of CE in Spain compared with areas in which similar problems in the CE field exist, and offer recommendations on how to overcome those limitations. Specifically, we believe that the introduction of national registries for CE with online data entry, following the example set by the European Registry for Alveolar Echinococcosis, would help streamline data collection on CE by eliminating the need for evaluating and integrating data from multiple regions, by avoiding duplication of data from patients who access several different health facilities over time, and by providing much needed clinical and epidemiological data that are currently accessible only to clinicians.

  3. USAGE OF UNMANNED AERIAL VEHICLES IN GENERAL AVIATION: CURRENT SITUATION AND PROSPECTS

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available The article aims at analyzing the current and future trends in usage of Unmanned Aerial Vehicles (UAV in gen- eral aviation (branches of economy. The main goal of the analysis is to determine the branches of economy, in which the usage of UAVs would be the most beneficial in the near- to mid-term future. The main requirements and restrictions of usage of the aircraft in general aviation were used as a basis for determining the types of operations, in which the usage of UAVs will be the most rational and effective. The effectiveness evaluation was based on the developed method, involving evaluation of the following factors such as: advantages of usage of manned aircraft, advantages of usage of unmanned air- craft, problems associated with the usage of manned aircraft, problems associated with the usage of unmanned aircraft. After evaluation of the mentioned aspects above the safety, operational productivity and ecological indicators were evaluat- ed. These qualitative assessments allowed identifying the branches of economy, where the usage of UAVs could potentially be the most advantageous. The article also discusses the possible strategies of UAVs development for general aviation. The so-called “mixed” strategy of UAV development is identified as the best in the current situation. This strategy combines the conversion of the existing military UAVs with the purpose of fitting them in to civilian use with the parallel development of brand new UAVs, which would be designed for operation in branches of economy right from the beginning (from scratch.

  4. Cystic Echinococcosis in Spain: Current Situation and Relevance for Other Endemic Areas in Europe

    Science.gov (United States)

    Rojo-Vazquez, Francisco A.; Pardo-Lledias, Javier; Francos-Von Hunefeld, Marcelo; Cordero-Sanchez, Miguel; Alamo-Sanz, Rufino; Hernandez-Gonzalez, Ana; Brunetti, Enrico; Siles-Lucas, Mar

    2011-01-01

    Cystic echinococcosis (CE) remains an important health problem in many regions of the world, both where no control measures have been implemented, and where control programs have been incompletely successful with ensuing re-emergence of the disease. In Spain, official data on CE show an increase in the proportion of intermediate hosts with CE during the last few years, and autochthonous pediatric patients have been reported, a sign of active local transmission of disease. A similar picture emerges from data reported to the European Food Safety Authority by other European countries. Nevertheless, several crucial aspects related to CE that would help better understand and control the disease have not been tackled appropriately, in particular the emergence of infection in specific geographical areas. In this respect, while some data are missing, other data are conflicting because they come from different databases. We review the current situation of CE in Spain compared with areas in which similar problems in the CE field exist, and offer recommendations on how to overcome those limitations. Specifically, we believe that the introduction of national registries for CE with online data entry, following the example set by the European Registry for Alveolar Echinococcosis, would help streamline data collection on CE by eliminating the need for evaluating and integrating data from multiple regions, by avoiding duplication of data from patients who access several different health facilities over time, and by providing much needed clinical and epidemiological data that are currently accessible only to clinicians. PMID:21283615

  5. WNV infection - an emergent vector borne viral infection in Serbia: Current situation

    Directory of Open Access Journals (Sweden)

    Petrović Tamaš

    2015-01-01

    Full Text Available West Nile virus (WNV is a neurovirulent mosquito-borne Flavivirus with zoonotic potential. Virus is maintained in nature in an enzootic transmission cycle between avian hosts and mosquito vectors, but occasionally infects other vertebrates. The infection in horses and humans can be asymptomatic or it can have different clinical manifestations ranging from light febrile diseases to fatal meningoencephalitis. Recently, the number, frequency and severity of outbreaks with neurological consequences for birds, humans and horses have increased dramatically throughout central and south Europe, including Serbia, posing a serious veterinary and public health problem. The emergency of WNV infections in Serbia is described through the current epidemiology situation based on recent data on the incidence of WNV infection among virus natural hosts and vectors; sentinel (horses and other animal species, and in human population. The results of the WNV serology studies conducted on horse blood samples collected in different occasions during the last six years, and the results of the serology studies conducted among other animal species like pigs, wild boars, roe deer and dogs in Serbia are presented and discussed. Also, the results of the first studies on WNV presence in mosquito vectors and in wild birds as virus natural hosts in Serbia are presented and analyzed. In addition, the data on the WNV serology studies conducted in human population in Serbia in the last few years, and the existing data of WNV outbreaks in 2012 and 2013 are included. Regarding the existing knowledge on WNV epidemiology situation, the crucial role of veterinary service in early detection of WNV presence and ongoing national program of WNV surveillance in sentinel animals, mosquitoes and wild birds are discussed.

  6. Veterinary medicinal products for the bees - the current situation and future strategies - an important topic discussed at European level

    Directory of Open Access Journals (Sweden)

    Alina Karina Draghici,

    2010-12-01

    Full Text Available To analyze the current situation and future issues relating to health and treatment options bees, bee breeders in Europe, agencies and drug manufacturers in Europe have held several meetings. One of thesetook place last year in December at the EMEA (European Medicines Agency in London, United Kingdom. The purpose of this meeting was to consider the current situation of pathology in bees to identify the most common diseases found in this species, identification and lack of treatment options for some diseases, and identifying solutions to improve the situation.

  7. [Current treatment situation and progress on bone defect of collapsed tibial plateau fractures].

    Science.gov (United States)

    Luo, Chang-qi; Fang, Yue; Tu, Chong-qi; Yang, Tian-fu

    2016-02-01

    Characteristics of collapsed tibial plateau fracture determines that the joint surface must remain anatomical reduction,line of force in tibial must exist and internal fixation must be strong. However, while renewing articular surface smoothness, surgeons have a lot of problems in dealing with bone defect under the joint surface. Current materials used for bone defect treatment include three categories: autologous bone, allograft bone and bone substitutes. Some scholars think that autologous bone grafts have a number of drawbacks, such as increasing trauma, prolonged operation time, the limited source, bone area bleeding,continuous pain, local infection and anesthesia,but most scholars believe that the autologous cancellous bone graft is still the golden standard. Allograft bone has the ability of bone conduction, but the existence of immune responses, the possibility of a virus infection, and the limited source of the allograft cannot meet the clinical demands. Likewise, bone substitutes have the problem that osteogenesis does not match with degradation in rates. Clinical doctors can meet the demand of the patient's bone graft according to patient's own situation and economic conditions.

  8. [Intraoperative neurophysiological monitoring in Spain: its beginnings, current situation and future prospects].

    Science.gov (United States)

    Cortes-Donate, V E; Perez-Lorensu, P J; Garcia-Garcia, A; Asociacion de Monitorizacion Intraquirurgica Neurofisiologica Espanola Amine, Asociacion de Monitorizacion Intraquirurgica Neurofisiologica Espanola Amine; Sociedad Espanola de Neurofisiologia Clinica Senfc, Sociedad Espanola de Neurofisiologia Clinica Senfc; Grupo de Trabajo de Monitorizacion Neurofisiologica Intraoperatoria de la Senfc, Grupo de Trabajo de Monitorizacion Neurofisiologica Intraoperatoria de la Senfc

    2018-05-01

    Intraoperative neurophysiological monitoring (IONM) is nowadays another tool within the operating room that seeks to avoid neurological sequels derived from the surgical act. The Spanish Neurophysiological Intra-Surgical Monitoring Association (AMINE) in collaboration with the Spanish Society of Clinical Neurophysiology (SENFC), and the IONM Working Group of the SENFC has been collecting data in order to know the current situation of the IONM in Spain by hospitals, autonomous communities including the autonomous cities of Ceuta and Melilla, the opinions of the specialists in clinical neurophysiology involved in this topic and further forecasts regarding IONM. The data was gathered from November 2015 to May 2016 through telephone contact and/or email with specialists in clinical neurophysiology of the public National Health System, and through a computerized survey that also includes private healthcare centers. With the data obtained, from the perspective of AMINE and the SENFC we consider that nowadays the field of medicine covered by IONM is considerably large and it is foreseen that it will continue to grow. Therefore, a greater number of specialists in Clinical Neurophysiology will be required, as well as the need for specific training within the specialty that involves increasing the training period of MIRs based on competencies due to the increase in techniques/procedures, as well as its complexity.

  9. Significance of single lung transplantation in the current situation of severe donor shortage in Japan.

    Science.gov (United States)

    Miyoshi, Ryo; Chen-Yoshikawa, Toyofumi F; Hijiya, Kyoko; Motoyama, Hideki; Aoyama, Akihiro; Menju, Toshi; Sato, Toshihiko; Sonobe, Makoto; Date, Hiroshi

    2016-02-01

    Although bilateral lung transplantation is the procedure of choice internationally, single lung transplantation is preferred in Japan because of the severe donor shortage except in cases of contraindications to single lung transplantation. This study aimed to evaluate the clinical characteristics of single lung transplant recipients and outcomes of this procedure at one of the largest lung transplant centers in Japan. Between April 2002 and May 2015, 57 cadaveric lung transplantations (33 single and 24 bilateral) were performed in Kyoto University Hospital. The clinical characteristics of the lung transplant recipients and outcomes of these procedures, including overall survival and postoperative complications, were investigated. Overall, the 1-, 3-, and 5-year survival rates were 86, 77, and 72 %, respectively, with a median follow-up period of 1.9 years. There was no significant difference in survival between patients who underwent single lung transplantations and those who underwent bilateral lung transplantations (p = 0.92). The median waiting time was significantly shorter for single lung transplant patients than for bilateral lung transplant patients (p = 0.02). Native lung complications were seen in 14 out of 33 patients (42 %) who underwent single lung transplantation. There was no significant difference in survival between patients with and without postoperative native lung complications. Single lung transplantation has been performed with acceptable outcomes in our institution. In the current situation of severe donor shortage in Japan, single lung transplantation can remain the first choice of treatment except in cases of contraindications to single lung transplantation.

  10. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  11. Canine and feline vector-borne diseases in Italy: current situation and perspectives

    Directory of Open Access Journals (Sweden)

    Dantas-Torres Filipe

    2010-01-01

    Full Text Available Abstract In Italy, dogs and cats are at risk of becoming infected by different vector-borne pathogens, including protozoa, bacteria, and helminths. Ticks, fleas, phlebotomine sand flies, and mosquitoes are recognized vectors of pathogens affecting cats and dogs, some of which (e.g., Anaplasma phagocytophilum, Borrelia burgdorferi, Dipylidium caninum, Leishmania infantum, Dirofilaria immitis, and Dirofilaria repens are of zoonotic concern. Recent studies have highlighted the potential of fleas as vectors of pathogens of zoonotic relevance (e.g., Rickettsia felis in this country. While some arthropod vectors (e.g., ticks and fleas are present in certain Italian regions throughout the year, others (e.g., phlebotomine sand flies are most active during the summer season. Accordingly, control strategies, such as those relying on the systematic use of acaricides and insecticides, should be planned on the basis of the ecology of both vectors and pathogens in different geographical areas in order to improve their effectiveness in reducing the risk of infection by vector-borne pathogens. This article reviews the current situation and perspectives of canine and feline vector-borne diseases in Italy.

  12. Radiation in pediatric health care: current situation and challenges in the Philippines

    International Nuclear Information System (INIS)

    Cabrera, Maria Gladys R.

    2009-01-01

    Radiation exposure to human health has been the topic of much research to date, focusing particularly on children as they are especially vulnerable and have longer life span to develop log term health effects. Taking into account the higher vulnerability of children, prevention of unnecessary radiation exposure is critical in pediatric patients. Issues such as pediatric patient receive a higher dose than necessary has been identified because adult computed tomography (CT) settings are used for children. Assessment of population exposures resulting from medical use of radiation is mainly available in industrialized countries, while in developing countries such as the Philippines, data are scarce. This information is very much scarce in the field of pediatric medical exposures and appropriate national surveys including frequency of pediatric procedures and children doses are still lacking. A broader and more effective participation of the regulatory authorities in such surveys could contribute to children risk assessment. The presentation explains the current situation, approach and challenges in the Philippines in dealing with radiation in pediatric health care. (author)

  13. The current situation and prospect of fundamental research about nuclear logging technology

    International Nuclear Information System (INIS)

    Zhang Feng; Wang Xinguang; Yuan Chao

    2010-01-01

    Nuclear logging technology is one of the important methods to evaluate complex hydrocarbon reservoir in the process of petroleum exploration and development. The fundamental research of nuclear logging is an important step of logging technology innovation. Through analyzing the current situation of the development of nuclear logging technology at home and abroad in recent years, the problems and gaps are pointed out in the field of fundamental research of nuclear logging at home, and the future development of new nuclear logging technologies is concisely analyzed. Therefore, the optimal design and processing are conducted from aspects of ray source, detector, data acquisition and processing method. In addition, the fundamental research of LWD and pulsed neutron logging technology is taken as the main breach. In the fundamental research of nuclear logging technology, innovative thinking should be expressed and the innovation should be achieved in every field of the development of nuclear logging technology. Meanwhile, the logging key lab should be taken as the platform and the latest achievement in the field of nuclear logging technology should be fully utilized. Thus, the level of independent R and D and technology innovation of logging tools will be raised and service for the exploration and development of petroleum and other mineral resources. (authors)

  14. Current situation of used household batteries in Iran and appropriate management policies.

    Science.gov (United States)

    Zand, A Daryabeigi; Abduli, M A

    2008-11-01

    Used household batteries are considered as hazardous wastes in many countries due to the potential environmental and human health risks associated with the heavy metals present in batteries. This article presents the current situation of waste household batteries and policies in Iran. Iran with more than 70 million people is a developing country where latest technologies like cell phones and laptops are in widespread use and battery consumption increases accordingly. The household battery demand in Iran has rapidly grown since 2001 and it is expected to increase more quickly in next years, due to increasing technological development. Based on the available data, more than 9800 metric tons of household batteries were imported into Iran in recent decade, with the market value of about US$ 42.6 million. At present, there is no program available in Iran regarding to collection, separation, recycling or safe disposal of used batteries. Therefore, almost all of the spent household are discarded into municipal solid waste (MSW) and sent to sanitary landfills. Appropriate policies to meet safe disposal of household batteries in Iran is also discussed in this investigation.

  15. [Current situation of suicide in Japan, and what pharmacists contribute to suicide prevention].

    Science.gov (United States)

    Matsumoto, Toshihiko

    2013-01-01

      In Japan, a national countermeasure has been forwarded since the enactment of the Basic Act on Suicide Countermeasures in 2006 and the Comprehensive Suicide Prevention Initiative in 2007. The distinctive policy of the Japanese countermeasure is expressed as the word, "comprehensive," which means that suicide prevention may not only be carried out only by mental health measures but also by comprehensive measures including chance of administrative practices. This policy is proper, although mental health measures appear to be too simple inclining to psychiatric treatments for the classic type of "depression" by a pharmacotherapy. The authors have insisted that mental health measures including psychiatric treatments are also required to be more comprehensive. This paper describes that benzodiazepine (BZ)-abuse problems including overdosing by suicidal intents have got worse recently as psychiatric clinics have increased and most of BZ abusers obtain the abused drugs form psychiatrists. This current situation indicates that pharmacists need to monitor psychiatrists' prescribing behavior and qualities of psychiatric treatment is required to be refined, suggesting pharmacists may be one of the "Gate Keeper," as supporting resources for suicide prevention. Additionally, this paper explained that basic attitudes and responses acquired by pharmacists as a supporter for suicide prevention.

  16. Current situation and problems of cancer-reproductive therapy from the standpoint of male reproductive therapy

    International Nuclear Information System (INIS)

    Shin, Takeshi; Tanaka, Takashi; Nishio, Koujiro; Arai, Manabu; Okada, Horoshi; Nozaki, Miwako; Kaji, Yasushi

    2017-01-01

    This paper reviewed the current situation and problems of cancer - reproductive therapy from the standpoint of male reproductive therapy. Common causes for male infertility include spermatogenic dysfunction, seminal duct dysfunction, and sexual dysfunction. Causes of male infertility in cancer patients include the presence of cancer itself, as well as pathological conditions due to surgery, radiation therapy, or chemotherapy for cancer, namely spermatogenic dysfunction, seminal duct dysfunction, and sexual dysfunction. The American Society of Clinical Oncology (ASCO) presents the risk classification of infertility due to anti-cancer drugs or radiotherapy. Cancer treating physicians evaluate infertility risk associated with treatment according to this risk classification and provide patients with information. If a patient wishes to preserve fertility, it is recommended in ASCO's fertility preservation guidelines to introduce the facilities that can store frozen sperm. Questionnaire surveys on sperm cryopreservation to blood physician show that the description of sperm cryopreservation is made at only about two-thirds of facilities and there is a problem that the systemization of cryopreservation has not progressed. The only way to acquire a baby in a patient who has undergone cancer treatment without cryopreservation and became permanent azoospermia is microscopic testis sperm collection and microinsemination. (A.O.)

  17. History, Current Situation, and Future Development of Endoscopic Neurosurgery in China.

    Science.gov (United States)

    Li, Chuzhong; Zhu, Haibo; Zong, Xuyi; Wang, Xinsheng; Gui, Songbai; Zhao, Peng; Zhang, Yazhuo

    2018-02-01

    During the past few decades, Chinese endoscopic neurosurgery has rapidly developed in synchrony with the rest of the world. The aim of this article is to review the development of Chinese endoscopic neurosurgery, including its birth, growth, current situation, and prospects. The history of Chinese endoscopic neurosurgery development can be divided into 3 stages: cognition and initial stage (1964-1995), exploration and maturity stage (1995-2006), and rapid development and promotion stage (2006-present). In the first stage, we mainly began to become aware of endoscopic neurosurgery from the translation and review of literature. In the mid to late 1990s, Chinese neurosurgery pioneers began using neuroendoscopic techniques. In the following decade, many leading neurosurgeons made persistent efforts to push the development of Chinese endoscopic neurosurgery forward, focusing on advocating for and promoting and popularizing neuroendoscopic technology. In the rapid development and promotion stage, many representative national and regional neurosurgical centers became skilled and efficient in the application of neuroendoscopic technology and became new advocates of the technology. The number of cases, level of technology, and treatment effectiveness are gradually nearing international standards. However, future development requires promotion of balanced development to decrease regional disparities, further strengthen international exchanges, follow the latest developments, and constantly innovate for continuous improvement. Following the dramatic efforts of several pioneers, development of Chinese endoscopic neurosurgery has been considerable, and it has become an important component of neurosurgery worldwide. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rogerio Matias Vidal da; Souza, Divanizia do Nascimento, E-mail: rmv.fisica@gmail.com [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Pinezi, Juliana Castro Dourado [Pontificia Universidade Catolica de Goias (PUC-Goias), Goiania, GO (Brazil); Macedo, Luiz Eduardo Andrade [Hospital Chama, Arapiraca, AL (Brazil)

    2014-05-15

    To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and methods: in the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results: sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion: the authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. (author)

  19. [Current situation and impact factors of acid deposition in main cites of Shandong Province].

    Science.gov (United States)

    Jia, Hong-yu; Zhang, Qiao-xian; Deng, Hong-bing; Zhao, Jing-zhu; Mu, Jin-bo; Zhang, De-zhi

    2006-12-01

    Based on the monitoring data for years in Shandong Province, current situation of acid rain in every city was assessed, and the temporal distribution of the dry, wet and total sulfur deposition in Jinan and Qingdao were studied. The results showed that Qingdao which had the largest precipitation acidity was the single city whose annul average precipitation pH was below 5. 60. The precipitation acidities in the main cities of Shandong Province were in a descent tendency. The total sulfur desposition in Jinan and Qingdao was basically stable or in a descent tendency, but also reached 10 t/(km(2)x a) or so. Among the total sulfur deposition flux, the dry deposition of sulfur had the greater contribution, and the contribution of SO2 dry deposition was higher than that of SO42- dry deposition. By analyzing the relation between the precipitation acidity and the SO2 discharge intensity, soil acidity and meteorological condition, the impact factors of acid precipitation in the cities of Shandong Province were revealed.

  20. The current situation and environmental conditions of green mussel farming in the gulf of Thailand

    Science.gov (United States)

    Keawtawee, T.; Songsangjinda, P.; Sangnoi, Y.; Uppabullung, A.

    2018-04-01

    This study investigated the current situation and environmental conditions of green mussel Perna viridis farming in Surat Thani, Phetchaburi and Samut Prakan provinces where were located in the gulf of Thailand. Samples were collected during April, August and November in 2014. Based on the results of this study, there were three major types of mussel culture patterns in Thailand: bouchot culture, longline culture (rope culture), and raft culture. Mussel farmers encountered problems on decreasing of larvae mussel in the water column, water quality degradation, high production cost and farmer’s lack of negotiation power to control the price. The water quality of the mussel farms, such as dissolved oxygen (DO), pH, salinity, electrical conductivity (EC), fecal coliforms bacteria and the total coliforms bacteria met the standard for aquaculture. However, the nutrient, such as ammonium (NH4-N), nitri-nitrogen (NO2-N), nitrate-nitrogen (NO3-N) and soluble reactive phosphorus (PO4-P) were higher than the value of marine aquaculture standard. The results of the contamination of Salmonella spp. bacteria were not found in the mussel’s tissue, however Escherichia coli was found at very low level.

  1. Current situation of energy conservation in high energy-consuming industries in Taiwan

    International Nuclear Information System (INIS)

    Chan, D.Y.-L.; Yang, K.-H.; Hsu, C.-H.; Chien, M.-H.; Hong, G.-B.

    2007-01-01

    Growing concern in Taiwan has arisen about energy consumption and its adverse environmental impact. The current situation of energy conservation in high energy-consuming industries in Taiwan, including the iron and steel, chemical, cement, pulp and paper, textiles and electric/electrical industries has been presented. Since the energy consumption of the top 100 energy users (T100) comprised over 50% of total industry energy consumption, focusing energy consumption reduction efforts on T100 energy users can achieve significant results. This study conducted on-site energy audits of 314 firms in Taiwan during 2000-2004, and identified potential electricity savings of 1,022,656 MWH, fuel oil savings of 174,643 kiloliters (KL), steam coal savings of 98,620 ton, and natural gas (NG) savings of 10,430 kilo cubic meters. The total potential energy saving thus was 489,505 KL of crude oil equivalent (KLOE), representing a reduction of 1,447,841 ton in the carbon dioxide emissions, equivalent to the annual carbon dioxide absorption capacity of a 39,131-ha plantation forest

  2. Risk factors of mesenteric venous thrombosis and current situation of diagnosis and treatment in China

    International Nuclear Information System (INIS)

    Zhuang Zhiwei; Zhu Huanxing; Xu Changsheng

    2010-01-01

    Objective: To investigate risk factors of mesenteric venous thrombosis and current situation of diagnosis and treatment in China. Methods: One hundred and seven case of mesenteric venous thrombosis reported in literature were analyzed. The literature from 2003 to 2007 were retrieved from Chinese Scientific and Technical Periodical Database and Wanfangdata. Results: One hundred and seven papers included 978 MVT patients, male: female = 1. 9:1, the average age was 47. 9. The most common risk factors were portal hypertension (28. 9% ), splenectomy (18. 8%) and thrombophlebitis (11. 5%) in 833 cases with integrated medical history. Final diagnosis was established by medical imageology (40. 0%) and exploratory laparotomy (60. 0%). The achievement ratio of thrombolysis therapy was 83. 9% (73 /87) by peripheral vein and 90. 0% (63 /70) by superior mesenteric artery. 34. 7% patients took warfarin orally after discharge. Conclusions: Portal hypertension, splenectomy and thrombophlebitis may be the most common risk factor for MVT; through peripheral vein or superior mesenteric artery urokinase thrombolytic therapy is an effective means of treatment of early MVT; MVT diagnostic awareness and anticoagulant therapy after surgery awareness of the importance is to be strengthened. (authors)

  3. The current situation of uranium resources exploration in East China: Problems, thought and countermeasure

    International Nuclear Information System (INIS)

    He Xiaomei; Mao Mengcai

    2014-01-01

    Based on analyzing the current situation of uranium resources and exploration effort in East China, the main existing problems, technical thought and countermeasure for the future exploration in East China are discussed in this paper. The degree of both uranium exploration and study in East China is relatively high, philosophy of scientific mineral-prospecting should be established in the new round of mineral prospecting. Under guidance of metallogenic theory of large mineralization cluster area and uranium metallogenic theory of multi-sources, previous data and research achievement should be analyzed and summarized. With the help of metallogenic model, useful methods and means should be applied to set up exploration model in order to realize news phase of model exploration, comprehensive exploration, 3D exploration and quantitative exploration. Efficiency of exploration of uranium resources should be strugglingly increased. High profitable uranium resources will be actively found with rich, shallow, near and easy features. The prospecting targets and strategy reserves of uranium resources will be increased in East China. (authors)

  4. Water Utility Management Strategies in Turkey: The current situation and the challenges

    Science.gov (United States)

    Alp, E.; Aksoy, M. N.; Koçer, B.

    2013-12-01

    As the effects of climate change becomes more prominent, current challenges related to water and wastewater management is becoming more serious. Providing water that satisfies environmental and safety standards in terms of quantity and quality is needed to maintain human life without compromising the need of future generations. Besides providing safe and affordable water, necessary treatment should be achieved according to several important factors such as receiving body standards, discharge standards, water reuse options. Therefore, management of water becomes more crucial than ever that states have to provide accessibility of safe water with affordable cost to its citizens with the means of effective utility management, including water treatment facilities, wastewater treatment facilities, water supply facilities and water distribution systems. Water utilities encounter with several challenges related to cost, infrastructure, population, legislation, workforce and resource. This study aims to determine the current situation and the necessary strategies to improve utility management in Turkish municipalities in a sustainable manner. US Environment Protection Agency (EPA) has formed a tool on effective utility management that assists utilities to provide a solution for both current and future challenges. In this study, we used EPA's guidelines and developed a survey consists of 60 questions under 10 sub-topics (Product Quality, Employee & Leadership Development, Stakeholder Understanding & Support, Operational Optimization, Infrastructure Stability, Financial Viability, Community Sustainability, Customer Satisfaction, Operational Resiliency, and Water Resource Adequacy). This survey was sent to the managers of 25 metropolitan municipalities in Turkey to assess the current condition of municipalities. After the evaluation of the survey results for each topic, including the importance given by managers, facilities were rated according to their level of achievement

  5. [Lung transplantation in Reunion Island, current situation from January 2005 till May 2015].

    Science.gov (United States)

    Simon, C; Allou, N; Schlossmacher, P; Gendry, T; Delay, L; Gazaille, V

    2017-04-01

    Lung transplantation (LT) is a therapeutic option for patients with terminal respiratory failure and high risk of mortality in two years. Until now, this activity is not performed in Reunion Island. The candidate potential are thus directed to the metropolitan reference centres causing logistics and financials constraints. This work presents a current situation of the pulmonary transplantation in Reunion Island. This retrospective study includes patients from Reunion Island with respiratory insufficiency who have been transferred to metropolitan centres to apply to LT. The selection was made from January, 2005 till May, 2015. Twenty-nine patients included, aged from 14 to 64 years, were transferred to metropolitan France: 13 patients with cystic fibrosis, 13 patients with pulmonary fibrosis, 1 patients with bronchiectasis, 1 patient with chronic obstructive pulmonary disease (COPD) and 1 patient with pulmonary arterial hypertension. Fifteen patients underwent LT (4 live in Reunion Island, 5 live in metropolitan France and 6 are dead), 1 patient is alive on waiting list, 3 died on the waiting list, 7 patients were refused for transplantation and 3 patients are lost to follow-up. The number of patients transferred for LT increases over 10 years with a maximal incidence in 2013 of 7 repatriated patients including 3 transplanted patients. LT could be performed in half of our patients with possible come back and follow-up on Reunion Island. Indications follow the current trends except an under representation of COPD. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Family medicine practice in Saudi Arabia: The current situation and Proposed Strategic Directions Plan 2020.

    Science.gov (United States)

    Al-Khaldi, Yahia M; Al-Ghamdi, Essam A; Al-Mogbil, Tariq I; Al-Khashan, Hesham I

    2017-01-01

    The objectives of this study were to assess the current situation of the teaching and training of undergraduate and postgraduate programs in family medicine in KSA, assess the current practice of family medicine, and draw a roadmap to achieve Saudi vision 2020. This study was conducted with the support and collaboration of the Primary Health Care Department of the Ministry of Health, Saudi Arabia, and World Health Organization (EMRO) in November 2015. Based on the literature review of previous studies conducted for similar purposes, relevant questionnaires were developed. These consisted of four forms, each of which was directed at a different authority to achieve the above-mentioned objectives. Data of all questionnaires were coded, entered, and analyzed using SPSS version 16. There are 2282 primary health-care centers (PHCCs), 60% of which are in rural areas. More than half of the PHCCs have a laboratory and more than one-third have a Radiology Department. Out of the 6107 physicians, 636 are family physicians (10%). All medical colleges have a family medicine department with a total staff of 170 medical teachers. Thirteen departments run family medicine courses of 4-8 weeks' duration for students. Fourteen colleges have internship programs in family medicine and four colleges have postgraduate centers for family medicine (27%). There are 95 training centers for Saudi Board (Saudi Board of Family Medicine [SBFM]) and 68 centers for Saudi Diploma (Saudi Diploma of Family Medicine [SDFM]). The total number of trainers was 241, while the total trainees were 756 in SBFM and 137 in SDFM. This survey showed that there is a shortage of qualified family physicians in all health sectors in Saudi Arabia as a result of the lack of a strategic plan for the training of family physicians. A national strategic plan with specific objectives and an explicit budget are necessary to deal with this shortage and improve the quality of health-care services at PHCCs.

  7. Sustainability of UK shale gas in comparison with other electricity options: Current situation and future scenarios.

    Science.gov (United States)

    Cooper, Jasmin; Stamford, Laurence; Azapagic, Adisa

    2018-04-01

    Many countries are considering exploitation of shale gas but its overall sustainability is currently unclear. Previous studies focused mainly on environmental aspects of shale gas, largely in the US, with scant information on socio-economic aspects. To address this knowledge gap, this paper integrates for the first time environmental, economic and social aspects of shale gas to evaluate its overall sustainability. The focus is on the UK which is on the cusp of developing a shale gas industry. Shale gas is compared to other electricity options for the current situation and future scenarios up to the year 2030 to investigate whether it can contribute towards a more sustainable electricity mix in the UK. The results obtained through multi-criteria decision analysis suggest that, when equal importance is assumed for each of the three sustainability aspects shale gas ranks seventh out of nine electricity options, with wind and solar PV being the best and coal the worst options. However, it outranks biomass and hydropower. Changing the importance of the sustainability aspects widely, the ranking of shale gas ranges between fourth and eighth. For shale gas to become the most sustainable option of those assessed, large improvements would be needed, including a 329-fold reduction in environmental impacts and 16 times higher employment, along with simultaneous large changes (up to 10,000 times) in the importance assigned to each criterion. Similar changes would be needed if it were to be comparable to conventional or liquefied natural gas, biomass, nuclear or hydropower. The results also suggest that a future electricity mix (2030) would be more sustainable with a lower rather than a higher share of shale gas. These results serve to inform UK policy makers, industry and non-governmental organisations. They will also be of interest to other countries considering exploitation of shale gas. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Classification of radiation effects for dose limitation purposes: history, current situation and future prospects

    Science.gov (United States)

    Hamada, Nobuyuki; Fujimichi, Yuki

    2014-01-01

    Radiation exposure causes cancer and non-cancer health effects, each of which differs greatly in the shape of the dose–response curve, latency, persistency, recurrence, curability, fatality and impact on quality of life. In recent decades, for dose limitation purposes, the International Commission on Radiological Protection has divided such diverse effects into tissue reactions (formerly termed non-stochastic and deterministic effects) and stochastic effects. On the one hand, effective dose limits aim to reduce the risks of stochastic effects (cancer/heritable effects) and are based on the detriment-adjusted nominal risk coefficients, assuming a linear-non-threshold dose response and a dose and dose rate effectiveness factor of 2. On the other hand, equivalent dose limits aim to avoid tissue reactions (vision-impairing cataracts and cosmetically unacceptable non-cancer skin changes) and are based on a threshold dose. However, the boundary between these two categories is becoming vague. Thus, we review the changes in radiation effect classification, dose limitation concepts, and the definition of detriment and threshold. Then, the current situation is overviewed focusing on (i) stochastic effects with a threshold, (ii) tissue reactions without a threshold, (iii) target organs/tissues for circulatory disease, (iv) dose levels for limitation of cancer risks vs prevention of non-life-threatening tissue reactions vs prevention of life-threatening tissue reactions, (v) mortality or incidence of thyroid cancer, and (vi) the detriment for tissue reactions. For future discussion, one approach is suggested that classifies radiation effects according to whether effects are life threatening, and radiobiological research needs are also briefly discussed. PMID:24794798

  9. [Current situation of the organisation, resources and activity in paediatric cardiology in Spain].

    Science.gov (United States)

    Sánchez Ferrer, Francisco; Castro García, Francisco José; Pérez-Lescure Picarzo, Javier; Roses Noguer, Ferrán; Centeno Malfaz, Fernándo; Grima Murcia, María Dolores; Brotons, Dimpna Albert

    2018-04-26

    The results are presented on the «current situation of the organisation, resources and activity in paediatric cardiology in Spain». It was promoted by the Spanish Society of Paediatric Cardiology and Congenital Heart disease. An analysis was carried out on the results obtained from a specifically designed questionnaire, prepared by the Spanish Society of Paediatric Cardiology and Congenital Heart disease, that was sent to all hospitals around the country that offer the speciality of paediatric cardiology. A total of 86 questionnaires were obtained, including 14 hospitals that perform cardiac surgery on children. A total of 190 paediatric cardiology consultants, 40 cardiac surgeons, and 27 middle grade doctors performing their paediatric residency (MIR program) were identified. All hospitals had adequate equipment to perform an optimal initial evaluation of any child with a possible cardiac abnormality, but only tertiary centres could perform complex diagnostic procedures, interventional cardiology, and cardiac surgery. In almost all units around the country, paediatric cardiology consultants were responsible for outpatient clinics and hospital admissions, whereas foetal cardiology units were still mainly managed by obstetricians. The number of diagnostic and therapeutic procedures was similar to those reported in the first survey, except for a slight decrease in the total number of closed cardiac surgery procedures, and a proportional increase in the number of therapeutic catheterisations. Paediatric Cardiology in Spain is performed by paediatric cardiology consultants that were trained initially as general paediatricians, and then completed a paediatric cardiology training period. Almost all units have adequate means for diagnosis and treatment. Efforts should be directed to create a national registry that would not only allow a prospective quantification of diagnostic and therapeutic procedures, but also focus on their clinical outcomes. Copyright © 2018

  10. [Clinical research outside of teaching hospitals: Current situation in north-eastern France].

    Science.gov (United States)

    Goetz, C; Dupoux, A; Déloy, L; Hertz, C; Jeanmaire, T; Parneix, N

    2015-04-01

    Most clinical research in France takes place in teaching hospitals. There are, however, many advantages to developing it in other hospitals: access to innovative treatments, improvement in healthcare quality, attractiveness of hospitals, increased trial inclusion rates and reduced selection bias. The objectives of our study were to report on the current situation of clinical research outside teaching hospitals. A three-stage survey was conducted between January 2012 and May 2013 in non-teaching hospitals of north-eastern France. First, questionnaires were sent to administrative and medical boards of all hospitals with more than 100 beds, then to head doctors of every department in hospitals with more than 300 beds and finally meetings were organized with members of 20 selected hospitals. The administrative and medical boards of 85 hospitals participated in the first stage of the survey; half of these hospitals were engaged in clinical research activities and for 10 the internal structuring was cross-disciplinary. Answers from 178 departments were obtained during the second stage; 47% reported a clinical research activity. Meetings with research teams in 20 hospitals allowed us to identify difficulties concerning research funding, transversal organization and sponsoring. Clinical research existed in more than half of the respondent non-teaching hospitals. Obstacles to its development can be grouped in three categories: 1) internal structuring of clinical research, 2) access to information and knowledge of how clinical research functions and to interlocutors outside the hospital and 3) access to skills necessary to sponsor clinical research. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Epidemiology in Latin America and the Caribbean: current situation and challenges.

    Science.gov (United States)

    Barreto, Sandhi M; Miranda, Jaime J; Figueroa, J Peter; Schmidt, Maria Inês; Munoz, Sergio; Kuri-Morales, P Pablo; Silva, Jarbas B

    2012-04-01

    This article analyses the epidemiological research developments in Latin America and the Caribbean (LAC). It integrates the series commissioned by the International Epidemiological Association to all WHO Regions to identify global opportunities to promote the development of epidemiology. Health situations of the regions were analysed based on published data on selected mortality, morbidity and risk factors. Epidemiological publication output by country was estimated by Medline bibliometrics. Internet and literature searches and data provided by key informants were used to describe perspectives on epidemiological training, research and funding. Despite important advances in recent decades, LAC remains the world's most unequal region. In 2010, 10% of the LAC's people still lived in conditions of multidimensional poverty, with huge variation among countries. The region has experienced fast and complex epidemiological changes in past decades, combining increasing rates of non-communicable diseases and injuries, and keeping uncontrolled many existing endemic and emerging diseases. Overall, epidemiological publications per year increased from 160 articles between 1961 and 1970 to 2492 between 2001 and 2010. The increase in papers per million inhabitants in the past three decades varied from 57% in Panama to 1339% in Paraguay. Universities are the main epidemiological training providers. There are at least 34 universities and other institutions in the region that offer postgraduate programmes at the master's and doctoral levels in epidemiology or public health. Most LAC countries rely largely on external funding and donors to initiate and sustain long-term research efforts. Despite the limited resources, the critical mass of LAC researchers has produced significant scientific contributions. FUTURE NEEDS: The health research panorama of the region shows enormous regional discrepancies, but great prospects. Improving research and human resources capacity in the region will

  12. An Investigation on the Current Situation of Management Information Systems Discipline in Turkey

    Directory of Open Access Journals (Sweden)

    Serdar YARLIKAŞ

    2015-09-01

    Full Text Available The purpose of this research is to investigate the development of management information systems field by evaluating the theses conducted at universities in Turkey in the departments of management information systems and science of management information systems. First, this study aims to determine the distribution of the theses in terms of years, subjects and the research methods used. Another purpose of this study was to determine which of the related disciplines of management information systems are used most in the theses. In addition, as a result of the study, the compatibility degree between the theses written and the courses taught in the graduate programs of management information systems were determined. In this research, content analysis method is used. Through this method, each of the theses was evaluated with a 10-question ‘thesis evaluation question set' constructed towards the purpose of the study. Through this evaluation, the current situation of the field was determined. It was observed that the number of doctoral theses associated with the field was less. Using the combination of qualitative and quantitative techniques most in the theses denoted that the interdisciplinary approaches were adopted in the theses associated with management information systems. It was observed that the literature analysis and survey techniques were the most studied research methods in the theses. Besides, statistical techniques were used highly in the theses. As a result of this study, it was concluded that out of the associated disciplines of management information systems, management science, computer science and statistics disciplines were more associated with the investigated theses. When the study results were evaluated as a whole, it was seen that significant progress was made in the discipline of management information systems compared to the early 2000s.

  13. Current situation of the facilities, equipments and human resources in nuclear medicine in Argentina

    International Nuclear Information System (INIS)

    Chiliutti, Claudia A.

    2008-01-01

    The current situation of nuclear medicine in Argentina, taking into account the facilities, their equipment and human resources available is presented in this paper. A review and analysis of the equipment, including technical characteristics and a survey of the professionals and technicians of the area, was carried out. In Argentina, there are 266 centers of nuclear medicine distributed all over the country. The operating licenses are granted by the Nuclear Regulatory Authority (Autoridad Regulatoria Nuclear - ARN). Forty four percent of the installed equipment are SPECT of 1 or 2 heads and 39,4 % are gamma camera. Besides, there are eleven PET operating in Argentina. There are 416 nuclear medicine physicians with individual permit for diagnostic purposes and 50% of them has also individual permit for treatment purposes. With the purpose of analyzing the regional distribution of the available resources in nuclear medicine, the country was divided into 7 geographical regions: City of Buenos Aires, Province of Buenos Aires, Pampa, Cuyo, Northeast, Northwest and Patagonia. From the analysis of the gathered information it is possible to conclude that the nuclear medicine equipment as well as the personnel present an irregular distribution, with a major concentration in the City of Buenos Aires and Province of Buenos Aires. The Northeast region presents the lowest number of Nuclear Medicine centers and the Patagonia region has the lowest number of medicine nuclear physicians with individual permits. The number of SPECT and gamma cameras is 7,3 per million of inhabitants. The information about the available resources in nuclear medicine presented in this paper and its comparison with the international information available provide elements for a better planning of the future activities in the area not only for the operators but also from the regulatory point of view. (author)

  14. Current situation of Islamabad solid waste dumpsite and options for improvement

    International Nuclear Information System (INIS)

    Baig, M.A.; Elahi, R.E.; Malik, M.

    2003-01-01

    A study was undertaken to assess the existing situation of H-12 dumpsite, where solid waste from Islamabad City is being dumped since 1988, and to propose options for its improvement. The study methodology involved collection of baseline information, topographical survey, analysis of leachate samples, characterization of incoming waste and evaluation of options for rehabilitation and improvement of the site. The results of the study revealed that solid waste dumped at the H-12 dumpsite, which currently receives about 320 tons of solid waste daily, covers an area of 22.4 hectares. The corresponding volume and weight of the waste were found to be 0.45 million m3 and 0.143 million tons, respectively. Specific weight and moisture content of the old dumped waste were found to be 22 percent and 320 kg/m3, respectively. Analysis of leachate samples collected from the dumpsite were found to be highly contaminated. Characterization of solid waste delivered at the site showed that it mainly comprises a mix of construction and demolition waste, food waste and hospital waste thus indicating that material recovery operations would not be feasible. In order to improve and rehabilitate the dumpsite with a view to mitigate its adverse environmental impacts, three options were considered. These include (a) improvement and rehabilitation of the site without making provision for further inflow of waste; (b) improvement and rehabilitation of the dumpsite with provision to receive the waste for a period of another 10 years; and (c) shifting the dumped waste to the proposed Kurri Landfill site. Technical and financial aspects of all the three options are described and recommendations regarding the most environment friendly option are presented. (author)

  15. TBLT IN CHINA (2001-2011: THE CURRENT SITUATION, PREDICAMENT AND FUTURE

    Directory of Open Access Journals (Sweden)

    Luo Shaoqian

    2013-01-01

    Full Text Available Abstract: With the reform of English education in China since 2001, a communicative and task-based language teaching has emerged into Chinese English classroom. To understand task-based language teaching (TBLT practice in China, a synthesis study was conducted to analyze the current situation and predicament of TBLT in China over the last ten years based on the published TBLT articles (2001-2011 in Chinese journals and educational newspapers. The study shows that there is questioning and criticism on the effectiveness of TBLT in the forein languagae teaching classes despite the amazing growth of research in TBLT in China. It is also found that the predicament of TBLT may be attributable to a variety of factors such as no professional and systematic training TBLT for teachers, little knowledge of the latest development of TBLT, differences in student English proficiency, gap between local educational levels, no enough educational funds as well as misunderstanding and mispractice of TBLT. Thus, how to appropriately adapt and localize TBLT in China has become the major concern of researchers and educators as well as teachers. To solve the problem, this paper puts forward some suggestions to localize TBLT in the Chinese context, which is concerned with (1 task design; (2 integrating target tasks and pedagogical tasks; (3 balance between meaning and form; (4 tasks for big classes; (5 developing school based textbooks and (6 combining tasks and other teaching principles. Such a context-based approach to TBLT could provide a reference for other contexts similar to China.

  16. Open access to journal articles in oncology: current situation and citation impact.

    Science.gov (United States)

    Hua, F; Sun, H; Walsh, T; Glenny, A-M; Worthington, H

    2017-10-01

    Recent years have seen numerous efforts and resources devoted to the development of open access (OA), but the current OA situation of the oncology literature remains unknown. We conducted this cross-sectional study to determine the current share and provision methods of OA in the field of oncology, identify predictors of OA status (OA versus non-OA), and study the association between OA and citation counts. PubMed was searched for oncology-related, peer-reviewed journal articles published in December 2014. Google, Google Scholar, PubMed, ResearchGate, OpenDOAR and OAIster were manually checked to assess the OA status of each included article. Citation data were extracted from Web of Science, Scopus and Google Scholar. Descriptive statistics were used to summarize the OA proportion (primary outcome) and OA provision methods. Multivariable logistic regression and multilevel generalized linear model analyses were performed to study predictors of OA status and the association between OA and citation counts, respectively. In a random sample of 1000 articles, 912 were deemed eligible and therefore included. Of these, the full-texts of 530 articles (58.1%; 95% CI: 54.9-61.3) were freely available online: 314 (34.4%) were available from publishers ('Gold road' to OA), 424 (46.5%) were available via self-archiving ('Green road' to OA). According to multivariable regression analyses, impact factor, publisher type, language, research type, number of authors, continent of origin, and country income were significant predictors of articles' OA status; OA articles received a citation rate 1.24 times the incidence rate for non-OA articles (95% CI: 1.05-1.47; P = 0.012). Based on our sample, in the field of oncology, 42% of recent journal articles are behind the pay-wall (non-OA) 1 year after publication; the 'Green road' of providing OA is more common than the 'Gold road'; OA is associated with higher citation counts. © The Author 2017. Published by Oxford University Press

  17. Current situation of pests targeted by Bt crops in Latin America.

    Science.gov (United States)

    Blanco, C A; Chiaravalle, W; Dalla-Rizza, M; Farias, J R; García-Degano, M F; Gastaminza, G; Mota-Sánchez, D; Murúa, M G; Omoto, C; Pieralisi, B K; Rodríguez, J; Rodríguez-Maciel, J C; Terán-Santofimio, H; Terán-Vargas, A P; Valencia, S J; Willink, E

    2016-06-01

    Transgenic crops producing Bacillus thuringiensis- (Bt) insecticidal proteins (Bt crops) have provided useful pest management tools to growers for the past 20 years. Planting Bt crops has reduced the use of synthetic insecticides on cotton, maize and soybean fields in 11 countries throughout Latin America. One of the threats that could jeopardize the sustainability of Bt crops is the development of resistance by targeted pests. Governments of many countries require vigilance in measuring changes in Bt-susceptibility in order to proactively implement corrective measures before Bt-resistance is widespread, thus prolonging the usefulness of Bt crops. A pragmatic approach to obtain information on the effectiveness of Bt-crops is directly asking growers, crop consultants and academics about Bt-resistance problems in agricultural fields, first-hand information that not necessarily relies on susceptibility screens performed in laboratories. This type of information is presented in this report. Problematic pests of cotton and soybeans in five Latin American countries currently are effectively controlled by Bt crops. Growers that plant conventional (non-Bt) cotton or soybeans have to spray synthetic insecticides against multiple pests that otherwise are controlled by these Bt crops. A similar situation has been observed in six Latin American countries where Bt maize is planted. No synthetic insecticide applications are used to control corn pests because they are controlled by Bt maize, with the exception of Spodoptera frugiperda. While this insect in some countries is still effectively controlled by Bt maize, in others resistance has evolved and necessitates supplemental insecticide applications and/or the use of Bt maize cultivars that express multiple Bt proteins. Partial control of S. frugiperda in certain countries is due to its natural tolerance to the Bt bacterium. Of the 31 pests targeted and controlled by Bt crops in Latin America, only S. frugiperda has shown

  18. Cerâmicas odontológicas: o estado atual Ceramic in dentistry: current situation

    Directory of Open Access Journals (Sweden)

    E. A. Gomes

    2008-09-01

    Full Text Available As cerâmicas dentais são conhecidas pela sua excelência em reproduzir artificialmente os dentes naturais. No século XVIII foi empregada pela primeira vez na Odontologia como dente artificial para próteses totais. A partir do século XX passou a ser utilizada para a confecção de restaurações metalocerâmicas e mais recentemente, com o aprimoramento da tecnologia cerâmica, surgiram as restaurações livres de metal. As cerâmicas têm apresentado rápida evolução em âmbito científico com o intuito de melhorar suas propriedades físicas e mecânicas para suprir as necessidades estéticas que são cada vez mais exigidas pela sociedade moderna. Nesse contexto, é preciso conhecer cada sistema cerâmico disponível atualmente no mercado, desde suas principais características até suas limitações, para saber indicá-lo de modo correto em cada situação clínica específica.Dental ceramics are known for their excellence in artificially reproduce natural teeth. In the XVIII century they were employed for the first time in Dentistry as artificial tooth for complete dentures. Since the XX century they were used to fabricate metal ceramic restorations and, nowadays, all-ceramic restorations are obtained as a result of ceramic technology improvement. Ceramics present a fast progress in the scientific field in order to improve their physical and mechanical properties to provide for aesthetic needs so required by modern society. In this context, it is important to know each ceramic system currently available on the market, regarding not only its main features but also its limitations, to an accurate indication for each specific clinical situation.

  19. Foot-and-mouth disease control in Zambia: A review of the current situation

    Directory of Open Access Journals (Sweden)

    Yona Sinkala

    2012-06-01

    . Presented with the current poverty levels failure to institute result oriented control measures will exacerbate the already life-threatening situation.

  20. A brief introduction on the current situation of radiation protection in China

    International Nuclear Information System (INIS)

    Guo Qinju; Li Xutong

    2005-01-01

    China is a fast developing country now and is seeking for a way of sustainable development as other countries in the worlds. Its situations concerning radiation protection and policies on nuclear power development should be quite noticeable to all the scientists working in these fields within the country and abroad as well. A brief introduction of the legislation and organizational framework; researches or situations of environmental radiation, disposal and management on radiation wastes, occupational exposure of nuclear industry are described in this paper. (author)

  1. First Case of Trichoderma longibrachiatum CIED (Cardiac Implantable Electronic Device)-Associated Endocarditis in a Non-immunocompromised Host: Biofilm Removal and Diagnostic Problems in the Light of the Current Literature.

    Science.gov (United States)

    Tascini, Carlo; Cardinali, Gianluigi; Barletta, Valentina; Di Paolo, Antonello; Leonildi, Alessandro; Zucchelli, Giulio; Corte, Laura; Colabella, Claudia; Roscini, Luca; Consorte, Augusta; Pasticci, Maria Bruna; Menichetti, Francesco; Bongiorni, Maria Grazia

    2016-04-01

    Trichoderma species are saprophytic filamentous fungi producing localized and invasive infections that are cause of morbidity and mortality, especially in immunocompromised patients, causing up to 53% mortality. Non-immunocompromised patients, undergoing continuous ambulatory peritoneal dialysis, are other targets of this fungus. Current molecular diagnostic tools, based on the barcode marker ITS, fail to discriminate these fungi at the species level, further increasing the difficulty associated with these infections and their generally poor prognosis. We report on the first case of endocarditis infection caused by Trichoderma longibrachiatum in a 30-year-old man. This patient underwent the implantation of an implantable cardioverter defibrillator in 2006, replaced in 2012. Two years later, the patient developed fever, treated successfully with amoxicillin followed by ciprofloxacin, but an echocardiogram showed large vegetation onto the ventricular lead. After CIED extraction, the patient had high-grade fever. The culturing of the catheter tip was positive only in samples deriving from sonication according to the 2014 ESCMID guidelines, whereas the simple washing failed to remove the biofilm cells from the plastic surface. Subsequent molecular (ITS sequencing) and microbiological (macromorphology) analyses showed that the vegetation was due to T. longibrachiatum. This report showed that T. longibrachiatum is an effective threat and that sonication is necessary for the culturing of vegetations from plastic surfaces. Limitations of the current barcode marker ITS, and the long procedures required by a multistep approach, call for the development of rapid monophasic tests.

  2. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    International Nuclear Information System (INIS)

    Alandete Germán, Salvador Pascual; Isarria Vidal, Santiago; Domingo Montañana, María Luisa; De la vía Oraá, Esperanza; Vilar Samper, José

    2015-01-01

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning

  3. [Septic shock due to infective endocarditis of stimulation system of implantable cardioverter-defibrillator].

    Science.gov (United States)

    Porubčinová, I; Porubčin, S; Stančák, B; Beňa, M; Sabol, F

    2012-01-01

    We present a case of a 60-year old patient hospitalized at the Department of Infectious Diseases and Travel Medicine, Medical faculty of UPJS and L. Pasteurs University Hospital in Kosice with suspected gastroenteritis. The patient was admitted to an intensive care unit because of the signs of septic shock. Within one hour from admission, the patient was administered early goal directed therapy for septic shock. Subsequently, infectious endocarditis of stimulation electrodes and tricuspid valve was identified as the origin of the infection. The stimulation system was then explanted from a stabilized and afebrile patient at the Department of cardiac Surgery of Eastern Slovak Institute of Cardiac and Vascular Diseases in Kosice. This case should emphasise frequently atypical course of this serious disease and the need for early identification of severe sepsis to enable timely management to affect mortality.

  4. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    on psychological distress in partners of ICD patients and recommendations for future research. PubMed and PsycInfo were searched in March 2010 using a priori defined search terms. This search and the additional hand search resulted in 22 studies, of which 13 were quantitative and eight qualitative. Sample sizes...... studies reported no impact of ICD shocks on distress levels or quality of life in partners. ICD indication as well as comorbid conditions, age, and the psychological profile of the partner were related to distress and quality of life. Domains of concern emerging from qualitative studies were related...... to care of the ICD patient, helplessness and uncertainties related to shocks, role changes, sexual activities, overprotectiveness, and driving. Partner levels of distress may be as high as that of ICD patients. Research with large samples is needed to further investigate the course and determinants...

  5. Low disease prevalence and inappropriate implantable cardioverter defibrillator shock rate in Brugada syndrome

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Jensen, Henrik Kjærulf; Eschen, Ole

    2012-01-01

    AimsBrugada syndrome (BrS) is an inherited channelopathy that predisposes to malignant ventricular arrhythmias and thereby syncope and sudden cardiac death. Prior studies characterizing BrS patients have used highly selected referral populations from tertiary centres and prevalence estimates have...... been carried out using electrocardiogram (ECG) surveys only. We aimed to identify and characterize all diagnosed BrS patients in Denmark (population 5.4 million).Methods and resultsBrugada syndrome patients were identified using several modalities including identification in all Danish tertiary......%) experienced inappropriate shocks during a median follow-up of 47 months. No patient died or experienced aborted sudden cardiac death during follow-up.ConclusionsWe report the first nationwide study of BrS patients. We found a low incidence of diagnosed definite BrS compared with estimates from ECG surveys...

  6. Inappropriate implantable cardioverter-defibrillator shocks in Brugada syndrome: Pattern in primary and secondary prevention

    Directory of Open Access Journals (Sweden)

    Aimé Bonny

    2017-01-01

    Conclusion: Inappropriate shock is common in Brugada syndrome during the early periods after an ICD implantation, and seems to be more likely in asymptomatic patients. This finding may warrant a review of the indications for ICD implantation, especially in the young and apparently healthy population of patients with Brugada syndrome.

  7. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  8. Extended charge banking model of dual path shocks for implantable cardioverter defibrillators.

    Science.gov (United States)

    Dosdall, Derek J; Sweeney, James D

    2008-08-01

    Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limited to experimental observations without a practical model to aid in improving dual path defibrillation techniques. The Charge Banking Model has been extended into a new Extended Charge Banking Model of defibrillation that represents small sections of the heart as separate RC circuits, uses a weighting factor based on published defibrillation shock field gradient measures, and implements a critical mass criteria to predict the relative efficacy of single and dual path defibrillation shocks. The new model reproduced the results from several published experimental protocols that demonstrated the relative efficacy of dual path defibrillation shocks. The model predicts that time between phases or pulses of dual path defibrillation shock configurations should be minimized to maximize shock efficacy. Through this approach the Extended Charge Banking Model predictions may be used to improve dual path and multi-pulse defibrillation techniques, which have been shown experimentally to lower defibrillation thresholds substantially. The new model may be a useful tool to help in further improving dual path and multiple pulse defibrillation techniques by predicting optimal pulse durations and shock timing parameters.

  9. Clinical effects and implications of cardiac rehabilitation for implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard

    2015-01-01

    rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results...... could help explain the quantitative results and bring forward additional information. OBJECTIVES:: The objectives are to (a) determine the clinical effect sizes of the primary outcomes and (b) triangulate the quantitative and qualitative findings. METHODS:: A total of 196 patients with first...... d was calculated. Qualitative interviews were conducted with 10 patients representing the rehabilitation group. Triangulation was carried out by integrating the findings from the quantitative and qualitative results in light of each other. RESULTS:: Clinically meaningful effects were found between...

  10. Implantable cardioverter defibrillators in the context of hypertrophic cardiomyopathy: a lesson in patient autonomy.

    Science.gov (United States)

    Bray, Jonathan James Hyett; Bucciarelli-Ducci, Chiara; Stuart, Graham

    2018-02-05

    Hypertrophiccardiomyopathy (HCM) is common, whereas the decision not to have an implantable cardioverterdefibrillator (ICD) when probably falling into a 'high-risk' category is not. A solicitor aged 45 years attended the inherited cardiac conditions clinic for review of her HCM and discussion about ICD implantation for primary prevention of sudden cardiac death (SCD). Despite a predicted 7% risk of SCD within the next 5 years, according to the European Society of Cardiology endorsed HCM Risk-SCD risk stratification tool, the patient opted against implantation of an ICD and comprehensively justifies her decision. This report discusses ethical aspects of a consultation offering ICD protection against SCD in the context of HCM and emphasises the clinicians' role in respecting patient autonomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. [The daily experience of the patient with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Palacios-Ceña, Domingo; Alonso-Blanco, Cristina; Cachón-Pérez, José Miguel; Alvarez-López, Cristina

    2010-01-01

    To describe the daily experience of patients with an automatic defibrillator (AD) implant and the adaptive changes of the patient. Qualitative and phenomenological research. Collection of data through; initially unstructured interview with half of the informants, semi-structured interviews through an open questions guide after the initial unstructured interviews and use of personal narratives of the informants. Analysis of the data using the Van Manen proposal. We analysed the interviews of 10 participants. We collected socio-demographic variables and identified the following themes, which respond to the question "How is life with an AD": It is life "with the two sides of the coin," living in constant wait and uncertainty, accepting change, developing adaptation strategies, renegotiating relationships and sexuality and it is to live transformed. The results of this study can be integrated into nurse clinical practice in areas such as valuation after discharge, changes in habits, control of treatment, notification of shocks, masking detection of symptoms and strategies that can jeopardise the bearer. Research needs to be developed that looks closer into the influence of other technological devices in people. Copyright 2009 Elsevier España, S.L. All rights reserved.

  12. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC......) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety....

  13. Quality of Life and Psychological Factors in Patients with Implantable Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Akiko Suyama-Chishaki, MD PhD

    2007-01-01

    CONCLUSION: To support ICD recipients both physically and mentally, not only the cardiologists but also specialists from other fields such as psychologists and nurse specialists are needed. Ancillary care must be provided through the support team. Cardiologists who determine whether ICD implantation is required must keep in mind potential psychological sequelae.

  14. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...... and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint...

  15. Shock as a determinant of poor patient-centered outcomes in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Van Den Broek, Krista C; Van Den Berg, Martha

    2010-01-01

    as an outcome, and compare the influence of ICD shock with other factors (e.g., heart failure and psychological factors) as determinants of outcomes, with a view to providing recommendations for clinical practice and future research. Based on the large-scale primary and secondary prevention trials (i.e., CABG......-PATCH, CIDS, AVID, AMIOVIRT, SCD-HeFT, MADIT-II, and DEFINITE), evidence for an association between ICD shocks and quality of life is mixed, with some indication that the influence of shocks may depend largely on the interval between shocks and assessment of quality of life. In order to improve the clinical...... management of ICD patients, we need to adopt a more rigorous and standardized methodology in future studies in order to be able to draw firm conclusions about the impact of ICD shocks on individual patients. We also need to acknowledge that the impact of shocks on psychological functioning and quality...

  16. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of pacing as part of device therapy for atrial arrhythmias.

  17. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    .9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms....... Heart rate of ≥80 bpm was associated with increased risk of mortality (HR=1.86; 95% CI=1.15-3.00; p=.011) in unadjusted analysis. In adjusted analyses, this relationship remained significant both with depression (HR=1.86, 95% CI=1.12-3.09; p=.017) and anxiety (HR=1.82, 95% CI=1.10-3.03; p=.021...

  18. Long-term survival of implantable cardioverter defibrillator recipients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mikhael F. El-Chami, MD, FACC, FHRS

    2017-10-01

    Conclusion: ESRD patients are at significantly increased risk of mortality as compared with a non-dialysis cohort. While the majority of these patients survive more than one year post-diagnosis, the three-year mortality is high (43%. Randomized studies addressing the benefits of ICDs in ESRD patients are needed to better define their value for primary prevention of SCD.

  19. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    -November 2009. A total number of 154 patients were needed in the trial. The data collected were compared with secondary data from patients who had recently suffered a Myocardial Infarction and from a healthy population. SPSS version 18.0 was used to analyze the data using t-test, chisquare and F...

  20. Failure to Treat Life-Threatening Ventricular Tachyarrhythmias in Contemporary Implantable Cardioverter-Defibrillators

    DEFF Research Database (Denmark)

    Thøgersen, Anna Margrethe; Larsen, Jacob Moesgaard; Johansen, Jens Brock

    2017-01-01

    . CONCLUSIONS: Complex and unanticipated interactions between manufacturer-specific features and generic programming can prevent therapy for VF. More data are needed to assess the risks and benefits of translating evidence-based detection parameters from one manufacturer to another....

  1. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.

    Science.gov (United States)

    Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather

    2016-06-01

    Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.

  2. Coping with Trauma and Stressful Events As a Patient with an Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Circulation My alerts Sign In Join Sign out Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  3. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  4. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Theuns, D.A.M.J.; Kupper, N.; Jordaens, L.; Pedersen, S.S.

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac

  5. My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?

    Science.gov (United States)

    ... al. 7 How Can We Boost My Child's Self-Esteem? No matter what the age, a fun way ... to treatment among children with cardiac disease . Cardiol Young . 2009 ; 19 : 545 – 551 . OpenUrl CrossRef PubMed 3. ↵ ...

  6. Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator.

    Science.gov (United States)

    Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F

    2018-06-12

    Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. 77 FR 20873 - Qualification of Drivers; Application for Exemptions; Implantable Cardioverter Defibrillators

    Science.gov (United States)

    2012-04-06

    ..., please include a self-addressed, stamped envelope or postcard or print the acknowledgement page that... variety known to be accompanied by syncope, dyspnea, collapse, or congestive cardiac failure. FMCSA..., collapse or congestive cardiac failure; and/or (2) which is likely to cause syncope, dyspnea, collapse, or...

  8. Sex differences in outcomes of primary prevention implantable cardioverter defibrillator therapy

    DEFF Research Database (Denmark)

    Sticherling, Christian; Arendacka, Barbora; Svendsen, Jesper Hastrup

    2018-01-01

    measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age...

  9. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Preben Ulrich; Zwisler, Ann-Dorthe

    2015-01-01

    year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO2), were used. Post-hoc analyses included SF-36 and ICD therapy history.Results:Comprehensive cardiac...

  10. Current Situation and Reforms Making Way for Future Positive Developments in the National Education System of Bulgaria: An Overview

    Science.gov (United States)

    Genova, Teodora

    2015-01-01

    This paper on the education system of Bulgaria is aimed at presenting its structure, current situation, problems and challenges that it faces, and on-going reforms leading to some positive trends in the development of the national education sector. At the moment of writing this paper in the year 2015, we will mark the 1160th anniversary of the…

  11. Land administration in Ecuador; Current situation and opportunities with adoption of fit-for-purpose land administration approach

    NARCIS (Netherlands)

    Todorovski, D.; Salazar, Rodolfo; Jacome, Ginella; Bermeo, Antonio; Orellana, Esteban; Zambrano, Fatima; Teran, Andrea; Mejia, Raul

    2018-01-01

    The aim of this paper is to explore current land administration situation in Ecuador and identify opportunities for fit-for-purpose (FFP) land administration approach that could improve the land administration functions for the country and its citizens. In this paper, initially literature about land

  12. The current situation and related problems of percutaneous vertebroplasty in clinical treatment of osteoporosis vertebral compression fracture

    International Nuclear Information System (INIS)

    Wang Luchang; Wu Chungen; Cheng Yongde

    2011-01-01

    As an effective, safe and less-invasive technique in interventional radiology, percutaneous vertebroplasty has satisfactory therapeutic results with fewer complications in treating osteoporosis vertebral compression fracture. This paper aims to make a comprehensive review of the current situation and related problems of percutaneous vertebroplasty in clinical treatment of osteoporosis vertebral compression fracture. (authors)

  13. The current situation of personal dose monitoring in Chinese medicine radiation and undamaged detection

    International Nuclear Information System (INIS)

    Zhang Liangan; Zhang Wenyi; Yuan Shuyu; Song Shijun; Chang Hexin; Sun Kai

    1993-01-01

    The situation of personal dose monitoring in γ(X) external exposure in China is mainly outlined. Thermoluminescent dosimetry (TLD) was adopted for personal dose measurement of the radiation workers. The computer software and data base for the work have been developed and applied. National intercomparison of TLD, monitoring control of personal dose monitoring in field, and technical training were carried out for quality control. In China, the dominant occupational exposures is X-ray diagnosis and it increases year by year, the highest values is about 22.6%. The highest values of annual collective dose and annual average of individual dose (AAID) are 272.8 man·Sv and 3.21 mSv respectively. This work shows that the fraction of the population receiving high dose is decreased with time rapidly. The situation for whole occupational exposures is also described. (3 tabs.)

  14. Politics and strategies for radioactive waste management: current situation and perspective for Latin America

    International Nuclear Information System (INIS)

    Amaral, Eliana; Cruz, Paulo Ferruz; Gonzalez, Abel; Telleria, Diego

    2013-01-01

    In some countries of the Latin America Region, policy and national strategy are well established and documented, while in others there is not an explicit formal declaration, although they may be implicit in the content of the laws, regulations and existing guides; but they are not consolidated in a single document, making it difficult to put into practice by the Government institutions, the organisms responsible for the regulation and those responsible for the safe management of waste. For practical reasons, the work concentrates the situation in the Region with the waste from medical, industrial practices, research and production, which generate a common problem in the region. This document also contains some recommendations to improve the situation in this topic in the Region

  15. Current Situation and Future Perspectives of Chinese Popular Music in Global Arena

    OpenAIRE

    Qian, Kun

    2012-01-01

    Music industry, as a rising star of cultural industries, is playing an increasingly important role in globalization of international economy. Nowadays western music has cornered most of the modern music market for a long time while Korea and Japan’s modern music developed quickly these last 20 years which gave Chinese music market huge pressure. Under the background the author aims to observe and analyze present market situation and future perspective of Chinese popular music in this study. ...

  16. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Science.gov (United States)

    Gilmour, Stuart; Miyagawa, Shoji; Kasuga, Fumiko; Shibuya, Kenji

    2016-01-01

    The Great East Japan Earthquake on 11th March 2011 and the subsequent Fukushima Dai-ichi nuclear power plant disaster caused radioactive contamination in the surrounding environment. In the immediate aftermath of the accident the Government of Japan placed strict measures on radio-contamination of food, and enhanced radio-contamination monitoring activities. Japan is a pilot country in the WHO Foodborne Disease Burden Epidemiology Reference Group (FERG), and through this initiative has an opportunity to report on policy affecting chemicals and toxins in the food distribution network. Nuclear accidents are extremely rare, and a policy situation analysis of the Japanese government's response to the Fukushima Dai-ichi nuclear accident is a responsibility of Japanese scientists. This study aims to assess Japan government policies to reduce radio-contamination risk and to identify strategies to strengthen food policies to ensure the best possible response to possible future radiation accidents. We conducted a hand search of all publicly available policy documents issued by the Cabinet Office, the Food Safety Commission, the Ministry of Health, Labor and Welfare (MHLW), the Ministry of Agriculture, Forestry and Fishery (MAFF) and prefectural governments concerning food safety standards and changes to radiation and contamination standards since March 11th, 2011. We extracted information on food shipment and sales restrictions, allowable radio-contamination limits, monitoring activities and monitoring results. The standard for allowable radioactive cesium (Cs-134 and Cs-137) of 100 Bq/Kg in general food, 50 Bq/Kg in infant formula and all milk products, and 10 Bq/Kg in drinking water was enforced from April 2012 under the Food Sanitation Law, although a provisional standard on radio-contamination had been applied since the nuclear accident. Restrictions on the commercial sale and distribution of specific meat, vegetable and fish products were released for areas at risk of

  17. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Directory of Open Access Journals (Sweden)

    Stuart Gilmour

    Full Text Available The Great East Japan Earthquake on 11th March 2011 and the subsequent Fukushima Dai-ichi nuclear power plant disaster caused radioactive contamination in the surrounding environment. In the immediate aftermath of the accident the Government of Japan placed strict measures on radio-contamination of food, and enhanced radio-contamination monitoring activities. Japan is a pilot country in the WHO Foodborne Disease Burden Epidemiology Reference Group (FERG, and through this initiative has an opportunity to report on policy affecting chemicals and toxins in the food distribution network. Nuclear accidents are extremely rare, and a policy situation analysis of the Japanese government's response to the Fukushima Dai-ichi nuclear accident is a responsibility of Japanese scientists. This study aims to assess Japan government policies to reduce radio-contamination risk and to identify strategies to strengthen food policies to ensure the best possible response to possible future radiation accidents.We conducted a hand search of all publicly available policy documents issued by the Cabinet Office, the Food Safety Commission, the Ministry of Health, Labor and Welfare (MHLW, the Ministry of Agriculture, Forestry and Fishery (MAFF and prefectural governments concerning food safety standards and changes to radiation and contamination standards since March 11th, 2011. We extracted information on food shipment and sales restrictions, allowable radio-contamination limits, monitoring activities and monitoring results. The standard for allowable radioactive cesium (Cs-134 and Cs-137 of 100 Bq/Kg in general food, 50 Bq/Kg in infant formula and all milk products, and 10 Bq/Kg in drinking water was enforced from April 2012 under the Food Sanitation Law, although a provisional standard on radio-contamination had been applied since the nuclear accident. Restrictions on the commercial sale and distribution of specific meat, vegetable and fish products were released for

  18. Current situation of hospital-based endocrinology and clinical nutrition in Spain.

    Science.gov (United States)

    Angeles Gálvez Moreno, M

    2008-01-01

    In 2006, the Healthcare Commission of Spanish Society of Endocrinology and Nutrition did a survey in order to know the actual situation of endocrinology and clinical nutrition healthcare in Public Sanitary Systems in Spain. The survey has been more extensive than the last and it has taken up number and geographical distribution of specialists in Spain in addition to data about clinical assistance. The mean of public hospitals with endocrinologist participation has been 50%. Copyright © 2008 Sociedad Española de Endocrinología y Nutrición. Published by Elsevier Espana. All rights reserved.

  19. Energy planning and management Current situation in the World, Turkey and ITU

    International Nuclear Information System (INIS)

    Onaygil, Sermin

    2006-01-01

    efficiency measures applied in the end-use sectors such as, industrial processes, heating and electrical home appliances. When energy intensity values of some countries are compared, it can be easily seen that Turkey, having the energy intensity of 0.38, consumes more energy than Japan having the value of 0.09, US with that of 0.25, world mean as 0.29 and even if Greece, Turkeys neighbor, as 0.20. Since Turkey is in the pre-accession period for being a member to European Union (EU), the harmonization with the EU legislation is carried out in every sector negotiated together with EU, including energy. The purposes of EU energy policy can be summarized as to improve competitiveness, energy supply security, energy efficiency, market share of renewable energy sources and to contribute protection of the environment. In each progress report prepared by EU for Turkey, it is stated that in order to harmonize with the related EU legislation and to decrease the energy intensity, Turkey should enact a framework energy efficiency law. Considering this suggestion, Draft Law on Energy Efficiency was prepared by taking the opinions of all related government and private sector representatives and it is waiting for ratification in Turkish Grand National Assembly. It is indicated that world energy consumption shall increase twice in 2050 as compared to 2005 while it is required to decrease this consumption to half for protecting the current climate of the world. Therefore, in order to prevent the adverse effects of climate change by means of economical measures, energy must be used 4 times efficient than it is used today. Within this framework, the major and inevitable measure is stated as the rational use of energy by each country considering their national situations including energy, economy and environment points of view. Generally, such studies are conducted by neutral and institutional organizations like Russian Energy Efficiency Center, Energy Conservation Center of Japan and Ukraine

  20. Indonesia municiple solid waste life cycle and environmental monitoring: current situation, before and future challenges

    Science.gov (United States)

    Susmono

    2017-03-01

    Indonesia is a big country with circa 250 million population, with more than 500 Local Governments and they are going to improve their municiple solid waste dumping method from Open Dumping to Sanitary Landfill (SLF) and to promote Reduce-Reuse-Recycling (3R) since many years ago, and it is strengthened by issuing of Solid Waste Management Act No.18/2008, MSW Government Regulation No.12/2012 and other regulations which are issued by Central Government and Local Governments. During “Water and Sanitation Decade 1980-1990” through “Integrated Urban Infrastructures Development Program” some pilot project such as 30 units of 3R station were developed in the urban areas, and modified or simplification of SLF call Controlled Landfill (CLF) were implemented. In the year of 2002 about 45 units of composting pilot projects were developed under “Western Java Environmental Management Project”, and the result was notified that some of them are not sustain because many aspects. At the beginning of 2007 until now, some pilot projects of 3R were continued in some cities and since 2011 some Waste Banks are growing fast. In the year of 2014 was recorded that of 70 % of 3Rs in Java Island well developed (2014, Directorate of Environment Sanitation Report), and in the year of 2012 was recorded that development of Communal Waste Banks were growing fast during two months from 400 units to 800 units (2012, Ministry of Environment report), now more Communal Waste Banks all ready exist. After the last overview monitoring activity by Ministry of Environment and JICA (2008), because of lack of data is very difficult to give current accurate information of Municiple Solid Waste Handling in Indonesia. Nevertheless some innovation are developed because of impact of many pilot projects, Adipura City Cleanest Competition among Local Governments and growing of the spirit of autonomous policy of Local Governments, but some Local Governments still dependence on Central Government support

  1. Current Situation Survey of Garbage Management in rural areas of Heilongjiang province

    Science.gov (United States)

    Yang, Yang; Wang, Shuai; Zhao, Yufeng

    2018-03-01

    This paper makes investigation to 120 administrative villages, count the the output, the distribution characteristics, the composition and the treatment model of the rural garbage at this stage. The research shows that the composition of the rural garbage is very complicated, the total annual output of rural garbage is 5 295 600 tonnes, and the daily output per capital of household garbage is 0.8925 kg. According to the situation of Heiliongjiang Province, this paper analyze the main problem during the garbage disposal, some control measures are presented, this reaesrch could provide basic data and research for the following treatment. The significant new findings of the research is that the rational governance path of garbage is that, first classification, second recycling and third harmless treatment.

  2. [The current situation of acupuncture definition in international organizations and legislation of some countries].

    Science.gov (United States)

    Sun, Yujie; Liu, Baoyan; He, Liyun; Wu, Xiaodong; Liu, Jia

    2017-12-12

    Acupuncture is developing rapidly in the world, and more attention is paid on acupuncture in various countries. Because of the cultural differences, there are different views on acupuncture between China and the west, which has brought influence and challenge to the development of acupuncture in the world. Acupuncture-related research is becoming increasingly extensive and complex, but the definition of acupuncture is lack of unified standards. The definition of acupuncture is in urgent need. Based on the analysis of acupuncture definition in the 201 international organizations of 48 countries on five continents and legislation of representative countries, this paper summarized the development status of acupuncture in foreign countries, and put forward that the definition of acupuncture should adopt the model of small connotation and large extension, integrate discipline superiority, expand the scope of acupuncture, and focus on the overall situation.

  3. Current situation and consideration of training base hospitals for residents of neurosurgical specialization in China

    Directory of Open Access Journals (Sweden)

    Feng-zeng JIAN

    2015-07-01

    Full Text Available Resident training of neurosurgical specialization will be tried and carried out in all over China. From the point of view of training base hospitals, a majority of 3A level hospitals have sufficient patients and good equipments which will ensure the success of training process; however, division of subspecialty, teaching motivation and teaching method still have a great potential to improve. In order to establish and improve training bases for residents of specialization, supervision from national administrative department should be strengthened; professional society also plays an important role in standardizing and controlling the training quality. Considering our nation's situation, integration of postgraduate education and resident training is worth of discussion. DOI: 10.3969/j.issn.1672-6731.2015.07.015

  4. TianShuiShi space breeding current situation and developing trend

    International Nuclear Information System (INIS)

    Wang Fuquan; Song Jianrong; Zhang Zhongping; Guo Zhenfang

    2011-01-01

    TianShuiShi is located in xian to lanzhou among two big cities, the five space launch, has vegetables, food, grasses, flowers, rape, melon and fruit, Chinese traditional medicine, amount of 8 categories of crops, such as the 22 new material after carrying the ground breeding work. Only vegetables on identified 23 aerospace new varieties. After ten years of space breeding, summarizes the present situation of TianShuiShi space breeding, development experience, characteristic, trends, and puts forward the development space breeding TianShuiShi organization and breeding of talent from the matching policy and grow up incentive mechanism, strengthen the cooperation and all over the country, establishing fiscal policy support from the aspects such as advice. (authors)

  5. [Investigation on current situation of malaria blood examinations in township-level hospitals of Nantong City].

    Science.gov (United States)

    Gui-Sheng, Ding; Cai-Qun, Cao; Ping, Miao; Mei-Fang, Gu; Xiao-Bin, Cao

    2016-11-18

    To understand the quality of malaria blood examinations in township-level hospitals, so as to provide the evidence for continuing the malaria blood examinations in the stage of post-malaria elimination. A total of 64 township hospitals were investigated and 640 negative malaria blood slides were scored individually according to 10 indicators in "Malaria Elimination Technical Scheme" in 2013 and 2014. The single and multiple indicators were calculated, and the work of blood examinations and situation of technicians were investigated. The data of malaria blood examinations and patient discovery in township hospitals of Nantong City were collected and analyzed during the period of 2011-2014. For the single indicator, 29.5% of the thick blood films did not reach the standard, and 35.8% of thin blood films did not reach the standard. For the multiple indicators, blood slides with more than 4 indicators below the standard (poor quality) accounted for 32.5%. From malaria blood examinations and malaria situation, the number of slides was 194 635 during the period of 2011-2014, and there were no local vivax malaria casesin 4 consecutive years from 2011 to 2014, and local malaria has been effectively controlled in Nantong City. For health facilities where malaria patients initially presented, the township and village level accounted for 16.3%, and county and higher level accounted for 83.7%. The quality of malaria blood examinations in township level hospitals of Nantong City is not high and the microscopic examination has a relatively low efficiency in the discovery of malaria cases. A new model for malaria blood examinations needs to be further explored.

  6. [School escorts in inclusive education- the current situation in the state of Baden-Wurttemberg].

    Science.gov (United States)

    Henn, Katharina; Thurn, Leonore; Besier, Tanja; Künster, Anne K; Fegert, Jörg M; Ziegenhain, Ute

    2014-11-01

    In the context of inclusive education, so-called «Schulbegleiter» (school escorts) have been installed to assist children with special needs. However, adequate conceptions of their role are lacking, and no provisions exist describing the exact tasks and duties of these school escorts. This article presents data on a statewide empirical study and provides information on the professional background, qualifications, and assignments of such escorts as well as the nature of the assisted children in the German state of Baden-Württemberg. The data were collected in nearly 50 % of all schools providing general education in Baden-Württemberg, and a total of 526 school escorts completed a questionnaire on their work. Children with special needs who received such assistance were aged 6 to 19 years (M = 10.4) and had a mental disorder in nearly three-fourths of all cases, with autism spectrum disorders being most common (59.4 %). The most frequent assignments of the escorts were providing practical assistance during classes and mobilizing the child as well as providing direct support in emotionally challenging situations. Such escorts can make a significant contribution to the inclusive education of disabled children. They do, however, need an adequate qualification and practical competences to meet the diverse challenges of children with special needs. Child and adolescent psychiatrists are supposed to stay involved in the process, not only by planning interventions, but also during the course of inclusive education itself. Thus, the emotional situation and adjustment of included children with mental disorders over time must be monitored adequately.

  7. Investigation of the current situation of massive blood transfusion in different surgical departments: a large multicenter study in China

    OpenAIRE

    Sun, Yang; Jin, Zhan-Kui; Xu, Cui-Xiang; Dang, Qian-Li; Zhang, Li-Jie; Chen, Hong-Nan; Song, Yao-Jun; Yang, Jiang-Cun

    2015-01-01

    Objective: This study aims to learn about the current situation of surgical massive blood transfusion of different surgical departments in China’s Tertiary hospitals, which could provide the basis for the formulation of guidelines on massive blood transfusion. Method: A multicenter retrospective research on the application status of blood constituents during massive blood transfusion was conducted and a comparative analyses of survival and length of hospitalization in patients from different ...

  8. Significant factors for work attractiveness and how these differ from the current work situation among operating department nurses.

    Science.gov (United States)

    Björn, Catrine; Lindberg, Magnus; Rissén, Dag

    2016-01-01

    The aim was to examine significant factors for work attractiveness and how these differ from the current work situation among operating department nurses. A second objective was to examine the associations between age, gender, length of employment, work engagement, work ability, self-rated health indicators and attractiveness of the current work situation. The attractiveness of work is rarely taken into account in research on nurse retention. To expand this knowledge, it is relevant to examine factors that make work attractive and their associations with related concepts. Correlational, cross-sectional survey using a convenience sample. Questionnaires were answered by 147 nurses in four operating departments in Sweden. Correlation and regression analyses were conducted. The nurses rated the significance of all factors of work attractiveness higher than they rated those factors in their current work situation; salary, organisation and physical work environment had the largest differences. The most significant attractive factors were relationships, leadership and status. A statistically significant positive correlation between work engagement and attractive work was found. In the multiple regression model, the independent variables work engagement and older age significantly predicted work attractiveness. Several factors should be considered in the effort to increase work attractiveness in operating departments and thereby to encourage nurse retention. Positive aspects of work seem to unite work engagement and attractive work, while work ability and self-rated health indicators are other important dimensions in nurse retention. The great discrepancies between the significance of attractive factors and the current work situation in salary, organisation and physical work environment suggest ways in which work attractiveness may be increased. To discover exactly what needs to be improved may require a deeper look into the construct of the examined factors. © 2015 John

  9. An analysis of current and desirable situation of electronic government service provision in rural areas of the Hamedan province

    Directory of Open Access Journals (Sweden)

    Mousa Aazami

    2017-04-01

    Full Text Available The informative society is seen as the central element of rural development at the beginning of the third millennium and the development of information technology and communication in villages has always been considered in current summits across the world. Nowadays, information and communication technology service offices are the basis of electronic government. Therefore, recognition of these offices is necessary for sustainable rural development. The purpose of this research was a comparative analysis between the current situation and the desirable situation of e-government services in the rural districts of the Hamedan province as perceived by their directors (Hamedan, Bahar and Famenin Counties. The study population consists of 91 respondents who were chosen and studied through the census method. The findings of this research study consist of two sections. The items related to satisfaction with the activities in information and communication technology service offices were prioritized in the first section. Moreover, the current and the desirable conditions for electronic service provision were identified. The gap between these two were analyzed in the second section. The results indicate that there is a significant difference between these two conditions of electronic service provisions in rural areas. This significant difference was recognized through the paired T test at the 0.05 level with 6.33 value that illustrates the existence of a gap between these two situations. Electronic government, information technology and communication, information and communication technology service offices

  10. A Survey of the Current Situation of Clinical Biobanks in China.

    Science.gov (United States)

    Li, Haiyan; Ni, Mingyu; Wang, Peng; Wang, Xiaomin

    2017-06-01

    The development of biomedical research urgently needs the support of a large number of high-quality clinical biospecimens. Therefore, human biobanks at different levels have been established successively in China and other countries at a significantly increasing pace in recent years. To better understand the general current state of clinical biobanks in China, we surveyed 42 clinical biobanks based in hospitals and collected information involving their management systems, sharing mechanisms, quality control systems, and informational management systems using closed questionnaire methods. Based on our current information, there has not been such a large-scale survey in China. An understanding of the status and challenges current clinical biobanks face will provide valuable insights for the construction and sustainable development of higher quality clinical biobanks.

  11. BK Virus-Associated Nephropathy: Current Situation in a Resource-Limited Country.

    Science.gov (United States)

    Yooprasert, P; Rotjanapan, P

    Data on BK virus-associated nephropathy (BKVAN) and treatment strategy in a resource-limited country are scarce. This study aimed to evaluate epidemiology of BKVAN and its situation in Thailand. A retrospective analysis was conducted among adult kidney transplant recipients at Ramathibodi Hospital from October 2011 to September 2016. Patients' demographic data, information on kidney transplantation, immunosuppressive therapy, cytomegalovirus and BK virus infections, and allograft outcomes were retrieved and analyzed. This study included 623 kidney transplant recipients. Only 327 patients (52.49%) received BK virus infection screening, and 176 of 327 patients had allograft dysfunction as a trigger for screening. BKVAN was identified in 39 of 327 patients (11.93%). Deceased donor transplantation and cytomegalovirus infection were associated with a higher risk of BKVAN (odds ratio = 2.2, P = .024, 95% confidence intervals [1.1, 4.43], and odds ratio = 2.6, P = .006, 95% confidence intervals [1.29, 5.26], respectively). BKVAN patients were at significantly higher risk for allograft rejection (P < .001) and allograft failure (P = .036). At the end of the study, 4 graft losses were documented (12.12%). BKVAN was associated with high rate of allograft rejection and failure. However, surveillance of its complications has been underperformed at our facility. Implementing a formal practice guideline may improve allograft outcome in resource-limited countries. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Prospects for Vascular Access Education in Developing Countries: Current Situation in Cambodia.

    Science.gov (United States)

    Naganuma, Toshihide; Takemoto, Yoshiaki

    2017-01-01

    We report our activities training doctors on vascular access procedures at International University (IU) Hospital in Cambodia through a program facilitated by Ubiquitous Blood Purification International, a nonprofit organization that provides medical support to developing countries in the field of dialysis medicine. Six doctors from Japan have been involved in the education of medical personnel at IU, and we have collectively visited Cambodia about 15 times from 2010 to 2016. In these visits, we have performed many operations, including 42 for arteriovenous fistula, 1 arteriovenous graft, and 1 percutaneous transluminal angioplasty. Stable development and management of vascular access is increasingly required in Cambodia due to increased use of dialysis therapy, and training of doctors in this technique is urgently required. However, we have encountered several difficulties that need to be addressed, including (1) the situation of personnel receiving this training, (2) problems with facilities, including medical equipment and drugs, (3) financial limitations, and (4) problems with management of vascular access. © 2017 S. Karger AG, Basel.

  13. Dirofilaria immitis and Angiostrongylus vasorum: The current situation of two major canine heartworms in Portugal.

    Science.gov (United States)

    Alho, Ana Margarida; Meireles, José; Schnyder, Manuela; Cardoso, Luís; Belo, Silvana; Deplazes, Peter; de Carvalho, Luís Madeira

    2018-03-15

    Cardiopulmonary nematodes are life-threatening pet parasites increasingly reported throughout Europe, with overlapping endemic areas. Dirofilaria immitis is a mosquito-borne whilst Angiostrongylus vasorum is a snail-borne pathogen. Both adult nematodes reside in the pulmonary arteries and right cardiac ventricle of domestic and wild canids, causing a wide spectrum of clinical presentations ranging from cough, dyspnoea and exercise intolerance to severe vascular and pulmonary disease with hearth failure that may lead to death. Information about the prevalence and distribution of cardiopulmonary parasites is essential for the control of animal diseases and, in the case of D. immitis, for the control of potentially associated illnesses in humans. However, in Portugal, heartworm studies are limited to few surveys and case reports, possibly underestimating the relevance of these nematodes. The present work reviews the data on cardiopulmonary dirofilariosis and angiostrongylosis in dogs in Portugal, providing a comprehensive update of the epidemiological situation during the past 20 years. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  14. The development and current situation of e-learning in Spanish Vocational Training

    Directory of Open Access Journals (Sweden)

    Cristian Jorge Garcia Marcos

    2016-06-01

    Full Text Available This paper is based on a study aimed to analyze organizational models at institutional level, technological tools and educational resources that distinguish online vocational studies throughout the Spanish territory. Quantitative and qualitative techniques were used for data collection. The most relevant results of the study were: there is an increase in the number of students enrolled in vocational training distance learning studies, materials specifically created and distributed in an open format for distance learning are used in some regions, absolute hegemony of Moodle as a virtual learning environment with its synchronous and asynchronous communication tools, existence of a gap between regions regarding the ratio of students per module and the hours devoted to tutorials, distance learning national implementation for the most vocational training studies, and creation of an interactive map specifically in order to show information collected in the study. Considering this situation, there are certain aspects which differ significantly among regions and which could be improved in two ways: firstly, throughout better communication and coordination, and secondly, by means of exchanging experiences between regions.

  15. Selection, Placement and Instatement of School Managers in Turkey: Evaluation of the Current Situation

    Science.gov (United States)

    Memisoglu, Salih Pasa

    2015-01-01

    The aim of this study is to evaluate the new regulations and current practices in terms of how they apply--to the selection, training and instatement of school administrators in Turkey. The successful implementation of Turkish National Development Plans is closely related to the knowledge and skills of managers working at various levels in every…

  16. Factitious prey and artificial diets for predatory lady beetles: current situation, obstacles, and approaches for improvement

    Science.gov (United States)

    Predatory lady beetles (Coleoptera: Coccinellidae) are important natural enemies of many pests in crop ecosystems throughout the world. Although several species are currently mass-reared and sold by biocontrol companies, there is an urgent need to reduce rearing costs. Cost effective mass rearing of...

  17. Current Situation of Household Income as a Factor, Having Impact on Mortgage Lending in Mongolia

    Directory of Open Access Journals (Sweden)

    Khuselchimeg Batbileg

    2012-04-01

    Full Text Available Amount of household income is the most important factor for housing loan. The article studies mortgage lending in Ulaanbaatar in 2007–2009, the factor, having great impact on the current economy of Mongolia, carries out the comparative analysis of capital’s medium and low income households and presents methods, which will help to solve these problems.

  18. Child injuries in Ethiopia: A review of the current situation with projections.

    Science.gov (United States)

    Li, Qingfeng; Alonge, Olakunle; Lawhorn, Collene; Ambaw, Yirga; Kumar, Smita; Jacobs, Troy; Hyder, Adnan A

    2018-01-01

    Heavy burden of child injuries and lack of policy response in Ethiopia call for an improved understanding of the situation and development of action plans from multiple governmental agencies and stakeholders. A consortium of international and Ethiopian researchers and stakeholders used extensive literature review and mixed analytical methods to estimate and project the burden of fatal and non-fatal child unintentional injuries in Ethiopia from 2015 to 2030. Estimates were derived for children aged 0-14 years. Data sources include a longitudinal study conducted by the Central Statistics Agency of Ethiopia and the World Bank as well as model-based estimates from World Health Organization 2017 and Global Burden of Disease 2016 project. Injuries caused about 25 thousand deaths among 0-14-year olds in Ethiopia in 2015. The leading cause of fatal child unintentional injuries in Ethiopia was road-traffic injuries, followed by fire, heat and hot substances and drowning. The death rate due to injuries among 0-14 years olds was about 50 percent higher in males than females. Rural children were exposed to a greater risk of injury than their urban peers. The longitudinal survey suggests that the incidence rate of child injuries increased during the period 2011-2014. The annual mortality caused by injuries is projected to increase from 10,697 in 2015 to 11,279 in 2020 and 11,989 in 2030 among children under 5 years, an increase of 12 percentage points in 15 years. The number of deaths among 0-14-year olds will be 26,463, 27,807, and 30,364 respectively in 2015, 2020, and 2030. As the first multisectoral collaboration on child injuries in Ethiopia, this study identified gaps in understanding of the burden of child injuries in Ethiopia. In consultation with Ethiopian government and other stakeholders, we propose starting an injury surveillance system at health clinics and hospitals and building an intervention package based on existing platforms.

  19. [Current situation and surveillance on dengue fever in China, 2005 - 2007].

    Science.gov (United States)

    Wang, Qin; Xu, Zhen; Dou, Feng-Man; Zhou, Hang; Wang, Xiao-Fang; Yin, Wen-Wu; Li, Qun

    2009-08-01

    To provide scientific evidence for prevention and control program on dengue fever through analyzing the situation of dengue fever in China, from 2005 to 2007. Data was collected from Internet-based National Notifiable Infectious Disease Reporting System, National Enhanced Dengue Fever Surveillance System and field investigation on dengue outbreaks, described and analyzed with descriptively and by SPSS statistical software. There was a total number of 1623 dengue cases (including 1356 laboratory confirmed cases and 267 probable cases) and 1 death case reported in China from 2005 to 2007. Among the identified cases, 151 were imported from foreign countries as the Southeast Asian countries, accounting for 9.3%, while the rest 1472 cases were reported from local infections, identified only in 9 cities from Guangdong and Fujian provinces. Data from the monitoring program on Aedes Mosquitoes indicated that: The indicators of BI from 84.6% of the sentinels were over 5, and BI from 72.2% of the sentinels were over 10. This index was especially at a higher level during summer in the southern areas of China. Aedes albopictus was found in all the sentinel sites while Aedes aegypti was only found in Hainan and in limited counties of Guangdong. No dengue virus was isolated from mosquito vectors collected from national sentinel sites, whereas positive results had been detected by PCR test in Guangdong province. It was assumed that a sustainable local circulation of dengue virus had not yet been established successfully in Mainland China according to the surveillance data. However, more local outbreaks reported in Guangdong and Fujian with the wide distribution and high-level density of aedes mosquito, low antibody level in healthy population and the increasing number of imported dengue cases, there is a potential of Dengue outbreaks in southern China. An integrated mosquito vector monitoring and management system is needed in high risk area to reduce the transmission of dengue

  20. Air pollution control residues from waste incineration: current UK situation and assessment of alternative technologies.

    Science.gov (United States)

    Rani, D Amutha; Boccaccini, A R; Deegan, D; Cheeseman, C R

    2008-11-01

    Current disposal options for APC residues in the UK and alternative treatment technologies developed world-wide have been reviewed. APC residues are currently landfilled in the UK where they undergo in situ solidification, although the future acceptability of this option is uncertain because the EU waste acceptance criteria (WAC) introduce strict limits on leaching that are difficult to achieve. Other APC residue treatment processes have been developed which are reported to reduce leaching to below relevant regulatory limits. The Ferrox process, the VKI process, the WES-PHix process, stabilisation/solidification using cementitious binders and a range of thermal treatment processes are reviewed. Thermal treatment technologies convert APC residues combined with other wastes into inert glass or glass-ceramics that encapsulate heavy metals. The waste management industry will inevitably use the cheapest available option for treating APC residues and strict interpretation and enforcement of waste legislation is required if new, potentially more sustainable technologies are to become commercially viable.

  1. The use of elearning in medical education: a review of the current situation

    Science.gov (United States)

    Choules, A P

    2007-01-01

    Computers are increasingly used in medical education. Electronic learning (elearning) is moving from textbooks in electronic format (that are increasingly enhanced by the use of multimedia adjuncts) to a truly interactive medium that can be delivered to meet the educational needs of students and postgraduate learners. Computer technology can present reliable, reusable content in a format that is convenient to the learner. It can be used to transcend geographical boundaries and time zones. It is a valuable tool to add to the medical teacher's toolkit, but like all tools it must be used appropriately. This article endeavours to review the current “state of the art2 in use of elearning and its role in medical education alongside non‐electronic methods—a combination that is currently referred to as “blended” learning. PMID:17403945

  2. The use of elearning in medical education: a review of the current situation.

    Science.gov (United States)

    Choules, A P

    2007-04-01

    Computers are increasingly used in medical education. Electronic learning (elearning) is moving from textbooks in electronic format (that are increasingly enhanced by the use of multimedia adjuncts) to a truly interactive medium that can be delivered to meet the educational needs of students and postgraduate learners. Computer technology can present reliable, reusable content in a format that is convenient to the learner. It can be used to transcend geographical boundaries and time zones. It is a valuable tool to add to the medical teacher's toolkit, but like all tools it must be used appropriately. This article endeavours to review the current "state of the art2 in use of elearning and its role in medical education alongside non-electronic methods-a combination that is currently referred to as "blended" learning.

  3. Air pollution control residues from waste incineration: Current UK situation and assessment of alternative technologies

    International Nuclear Information System (INIS)

    Amutha Rani, D.; Boccaccini, A.R.; Deegan, D.; Cheeseman, C.R.

    2008-01-01

    Current disposal options for APC residues in the UK and alternative treatment technologies developed world-wide have been reviewed. APC residues are currently landfilled in the UK where they undergo in situ solidification, although the future acceptability of this option is uncertain because the EU waste acceptance criteria (WAC) introduce strict limits on leaching that are difficult to achieve. Other APC residue treatment processes have been developed which are reported to reduce leaching to below relevant regulatory limits. The Ferrox process, the VKI process, the WES-PHix process, stabilisation/solidification using cementitious binders and a range of thermal treatment processes are reviewed. Thermal treatment technologies convert APC residues combined with other wastes into inert glass or glass-ceramics that encapsulate heavy metals. The waste management industry will inevitably use the cheapest available option for treating APC residues and strict interpretation and enforcement of waste legislation is required if new, potentially more sustainable technologies are to become commercially viable

  4. THE CURRENT SITUATION OF WATER RESOURCES IN IRRIGATED AGRICULTURE OF UZBEKISTAN

    OpenAIRE

    Djalalov, Sandjar

    1998-01-01

    Irrigation in Uzbekistan is of great importance since the country is an arid zone. The use of water in agriculture is described and its relationship as a constraint to economic development discussed. The current technical and organizational characteristics of irrigation systems need study and analysis to identify opportunities for improvements. The characteristics of demand for water at the farm level are described and irrigation and land improvement activities are outlined. Reform of water u...

  5. [Current situation and reflection on the prevention and treatment of burns in the elderly].

    Science.gov (United States)

    Zhang, J P; Huang, Y S

    2017-09-20

    With ageing of the population, it is estimated that the percentage of old people aged above 65 years old will be approached to 30% in China by 2035. This presents a considerable challenge to geriatric burn treatment, as elderly burn patients have more serious injuries, longer hospital lengths of stay, and higher rates of complications and mortality. In this article, we analyze the current status of burns in the elderly in China and the factors contributing to the outcome of the elderly, and put forward therapeutic strategies so as to improve the level of prevention and treatment of burns in the elderly.

  6. Molecular Targets for PET Imaging of Activated Microglia: The Current Situation and Future Expectations.

    Science.gov (United States)

    Tronel, Claire; Largeau, Bérenger; Santiago Ribeiro, Maria Joao; Guilloteau, Denis; Dupont, Anne-Claire; Arlicot, Nicolas

    2017-04-11

    Microglia, as cellular mediators of neuroinflammation, are implicated in the pathogenesis of a wide range of neurodegenerative diseases. Positron emission tomography (PET) imaging of microglia has matured over the last 20 years, through the development of radiopharmaceuticals targeting several molecular biomarkers of microglial activation and, among these, mainly the translocator protein-18 kDa (TSPO). Nevertheless, current limitations of TSPO as a PET microglial biomarker exist, such as low brain density, even in a neurodegenerative setting, expression by other cells than the microglia (astrocytes, peripheral macrophages in the case of blood brain barrier breakdown), genetic polymorphism, inducing a variation for most of TSPO PET radiopharmaceuticals' binding affinity, or similar expression in activated microglia regardless of its polarization (pro- or anti-inflammatory state), and these limitations narrow its potential interest. We overview alternative molecular targets, for which dedicated radiopharmaceuticals have been proposed, including receptors (purinergic receptors P2X7, cannabinoid receptors, α7 and α4β2 nicotinic acetylcholine receptors, adenosine 2A receptor, folate receptor β) and enzymes (cyclooxygenase, nitric oxide synthase, matrix metalloproteinase, β-glucuronidase, and enzymes of the kynurenine pathway), with a particular focus on their respective contribution for the understanding of microglial involvement in neurodegenerative diseases. We discuss opportunities for these potential molecular targets for PET imaging regarding their selectivity for microglia expression and polarization, in relation to the mechanisms by which microglia actively participate in both toxic and neuroprotective actions in brain diseases, and then take into account current clinicians' expectations.

  7. Current Situation, Determinants, and Solutions to Drug Shortages in Shaanxi Province, China: A Qualitative Study.

    Science.gov (United States)

    Yang, Caijun; Wu, Lina; Cai, Wenfang; Zhu, Wenwen; Shen, Qian; Li, Zongjie; Fang, Yu

    2016-01-01

    Drug shortages were a complex global problem. The aim of this study was to analyze, characterize, and assess the drug shortages, and identify possible solutions in Shaanxi Province, western China. A qualitative methodological approach was conducted during May-June 2015 and December 2015-January 2016. Semi-structured interviews were performed to gather information from representatives of hospital pharmacists, wholesalers, pharmaceutical producers, and local health authorities. Thirty participants took part in the study. Eight traditional Chinese medicines and 87 types of biologicals and chemicals were reported to be in short supply. Most were essential medicines. Five main determinants of drug shortages were detected: too low prices, too low market demands, Good Manufacturing Practice (GMP) issues, materials issues, and approval issues for imported drugs. Five different solutions were proposed by the participants: 1) let the market decide the drug price; 2) establish an information platform; 3) establish a reserve system; 4) enhance the communication among the three parties in the supply chain; and 5) improve hospital inventory management. Western China was currently experiencing a serious drug shortage. Numerous reasons for the shortage were identified. Most drug shortages in China were currently because of "too low prices." To solve this problem, all of the stakeholders, especially the government, needed to participate in managing the drug shortages.

  8. Smart grids in the colombian electric system: Current situation and potential opportunities

    Directory of Open Access Journals (Sweden)

    William Mauricio Giral Ramírez

    2017-07-01

    Full Text Available Context: This paper focuses on providing a functional analysis of smart grids, with the purpose of establishing a framework to identify the main characteristics of the current electric interconnection system in Colombia. It also names the positive incentives proposed by the Colombian government to support both research and development projects that implement non-conventional energy sources and promoting energy management based on efficiency. Method: An architecture model that describes the components interoperability of a smart grid is presented using a descriptive methodology. Results: The results include a list of the objectives established by the Colombian public and private entities related to energy development, specially focusing on the opportunities to provide some kind of artificial intelligence to the current electrical system. Conclusions: It is necessary for the Colombian energy system to supply the energy demand considering electrical safety, social equity, and the minimum environmental impact. These restrictions impose new challenges for the energy system itself: From a technical point of view, the traditional electrical grid must be outfitted with the characteristics of a smart grid, and from a legal perspective, it is essential to generate a clear regulatory framework that promotes the development of this type of technology.

  9. Cancer Control in Central and Eastern Europe: Current Situation and Recommendations for Improvement.

    Science.gov (United States)

    Vrdoljak, Eduard; Bodoky, Gyorgy; Jassem, Jacek; Popescu, Razvan A; Mardiak, Jozef; Pirker, Robert; Čufer, Tanja; Bešlija, Semir; Eniu, Alexandru; Todorović, Vladimir; Kubáčková, Kateřina; Kurteva, Galia; Tomašević, Zorica; Sallaku, Agim; Smichkoska, Snezhana; Bajić, Žarko; Šikić, Branimir I

    2016-10-01

    : The incidence of many cancers is higher in Western European (WE) countries, but mortality is frequently higher in Central and Eastern European (CEE) countries. A panel of oncology leaders from CEE countries participating in the South Eastern European Research Oncology Group (SEEROG) was formed in 2015, aiming to analyze the current status and trends of oncology care in CEE and to propose recommendations leading to improved care and outcomes. The SEEROG panel, meeting during the 11th Central European Oncology Congress, proposed the following: (a) national cancer control plans (NCCPs) required in all CEE countries, defining priorities in cancer care, including finance allocation considering limited health care budgets; (b) national cancer registries, describing in detail epidemiological trends; (c) efforts to strengthen comprehensive cancer centers; (d) that multidisciplinary care should be mandated by the NCCPs; (e) that smaller hospitals should be connected to multidisciplinary tumor boards via the Internet, providing access to specialized expertise; (f) nationwide primary prevention programs targeting smoking, obesity, and alcohol consumption and centrally evaluated secondary prevention programs for cervical, colorectal, and breast cancers; (g) prioritize education for all involved in cancer care, including oncology nurses, general practitioners, and palliative care providers; (h) establish outpatient care in day hospitals to reduce costs associated with the current inpatient model of care in CEE countries and to improve patients' quality of life; (i) long-term pharmacoeconomic evaluations of new therapies in CEE countries; (j) increase national oncology budgets in view of the higher mortality rates in CEE compared with WE countries; and (k) CEE countries urgently need help from the European Union to increase and monitor overall investment in cancer care. Significant differences in cancer incidence and mortality have been observed between European countries

  10. [Thirty years of platelet immunology in fetal and neonatal alloimmune thrombocytopenia management, current situation].

    Science.gov (United States)

    Petermann, R

    2017-09-01

    Fetal and neonatal allo-immune thrombocytopenia (FNAIT) is considered as a rare disease due to the incidence (1/1000-1/2000 births). The major complication of severe thrombocytopenia is bleeding and particularly intra-cranial hemorrhage and neurologic sequelae following. Serology and molecular biology developments have reconfigured the platelet immunology diagnosis. Anti-HPA-1a allo-immunisation is responsible for more than 80% FNAIT cases with a high recurrence rate of severe bleeding complications. Therapeutic management has changed over the coming years from an invasive concept associating fetal blood sampling and in utero platelet transfusion to a non invasive treatment by intravenous immunoglobulins injection (IVIg). The purpose of this article is to provide an update on FNAIT management in the light of current developments over the past 30years. Copyright © 2017. Published by Elsevier SAS.

  11. [Current situation and thoughts on radiofrequency ablation in the treatment of thyroid cancers].

    Science.gov (United States)

    Zhang, H; Dong, W W

    2017-08-01

    Radiofrequency ablation (RFA) was originally used primarily for the treatment of regional metastatic lymph nodes from recurrent thyroid cancers in the field of thyroid surgery. In recent years it is gradually used to treat a part of benign thyroid nodules. However, the domestic issues resulting from indiscriminately enlarged RFA indication and lack of standardization of therapy become more and more prominent, including initial treatment of operable thyroid cancers by RFA, which is against by the current consensus about RFA for patients with thyroid nodules and management guidelines for patients with thyroid cancers. Therefore, RFA should be avoided for initial treatment of operable thyroid cancers before the introduction of guidelines based on evidence-based medicine.

  12. Prospect and current situation survey of nuclear agricultural research in china

    International Nuclear Information System (INIS)

    Chai Lihong; Ye Qingfu; Hua Yuejin

    2008-01-01

    Based on the survey result, which investigated 22 related institutes and universities in the field of nuclear agricultural sciences in China in Sep. 2007, this paper introduces the current status of research conditions, existing facilities and research progress on isotope tracing technology, new biological resources creation, research of nuclear irradiation and irradiation processing technology form 1996 to 2006. Due to not enough financial supports on this field, the development of nuclear agricultural sciences was slow down. However, the solid basis set up during last several decades, and the great efforts made by all the researchers, significant social and economic achievements were gained. Some of the researches have already taken the leading position in the world. (authors)

  13. Current situation of management of radioactive wastes in the Instituto de Engenharia Nuclear, Brazil

    International Nuclear Information System (INIS)

    Zidan, Priscila M.; Silva, Joao C.P.; Echternacht, Marcus V.

    2000-01-01

    As its own legal responsibility, Nuclear Engineering Institute - IEN has received radioactive wastes generated in Rio de Janeiro and Espirito Santo states. But, from July 1997 to June 1999, IEN was not able to receive wastes because of the lack of space in the temporary repository. Recent studies show that increasing the treatment facilities could contribute to optimize the disposal of wastes. According to National Commission of Nuclear Energy resolutions, IEN was several times requested for discarding of lightning rods containing Am-241 and Ra-226. This fact motivated IEN to look for options to make possible the receiving of wastes until a new deposit were built. A temporary place was prepared and since last July it has been receiving wastes again. In this paper it is described the current structure of radioactive waste management at IEN, objectives and goals to be reached until December 2000. (author)

  14. Technical appraisal of the current situation in the field of radioactive waste management

    International Nuclear Information System (INIS)

    1985-01-01

    Industrial activities are regarded as safe even though a small risk always exists. The philosophy of radiation protection accepts this and recognises that some level of risk will also be associated with safe radioactive waste management. Therefore the objective of radioactive waste management is to look for a strategy which, taken as a whole, is considered safe and provides an acceptable balance of all the radiological, technical, social, political and economic considerations. The RWMC's appraisal underlines the need for such a balance while concentrating on radiological and technical factors, particularly on the long term safety aspects of radioactive waste management. The fundamental conclusion is that detailed short and long term safety assessments can now be made which give confidence that radiation protection objectives can be met with currently available technology for most waste types, and at a cost which is only a small fraction of the overall cost of nuclear-generated power

  15. Quality management of eLearning for medical education: current situation and outlook.

    Science.gov (United States)

    Abrusch, Jasmin; Marienhagen, Jörg; Böckers, Anja; Gerhardt-Szép, Susanne

    2015-01-01

    In 2008, the German Council of Science had advised universities to establish a quality management system (QMS) that conforms to international standards. The system was to be implemented within 5 years, i.e., until 2014 at the latest. The aim of the present study was to determine whether a QMS suitable for electronic learning (eLearning) domain of medical education to be used across Germany has meanwhile been identified. We approached all medical universities in Germany (n=35), using an anonymous questionnaire (8 domains, 50 items). Our results (response rate 46.3%) indicated very reluctant application of QMS in eLearning and a major information deficit at the various institutions. Authors conclude that under the limitations of this study there seems to be a considerable need to improve the current knowledge on QMS for eLearning, and that clear guidelines and standards for their implementation should be further defined.

  16. Fish farming of native species in Colombia: current situation and perspectives

    DEFF Research Database (Denmark)

    Cruz-Casallas, P. E.; Medina-Robles, V. M.; Velasco-Santamaria, Y. M.

    2011-01-01

    . The Colombian pisciculture is based on red Tilapia Oreochromis sp. (Linnaeus), Rainbow trout Oncorhynchus mykiss (Walbaum) and cachama blanca Piaractus brachypomus (Cuvier), which currently represent around 96% of the total national production. The remaining 4% comes from other farmed species such as bocachico......In Colombia and the rest of the world, the decrease in capture fisheries production has turned the aquaculture into an alternative source of protein for the populations food security as well as an important productive activity, generating employment and income for the rural communities...... Prochilodus magdalenae (Steindachner), carp Cyprinus carpio (Linnaeus) and yamu Brycon amazonicus (Spix & Agassiz). From the three main fish species, cachama blanca is the only native species, which has shown excellent performance in pond farming due to its rusticity, omnivorous habits, docility, meat quality...

  17. Inventory of managed aquifer recharge sites in Europe: historical development, current situation and perspectives

    Science.gov (United States)

    Sprenger, C.; Hartog, N.; Hernández, M.; Vilanova, E.; Grützmacher, G.; Scheibler, F.; Hannappel, S.

    2017-09-01

    Different types of managed aquifer recharge (MAR) schemes are widely distributed and applied on various scales and for various purposes in the European countries, but a systematic categorization and compilation of data has been missing up to now. The European MAR catalogue presented herein contains various key parameters collected from the available literature. The catalogue includes 224 currently active MAR sites found in 23 European countries. Large quantities of drinking water are produced by MAR sites in Hungary, Slovakia, the Netherlands, Germany, Finland, Poland, Switzerland and France. This inventory highlights that, for over a century, MAR has played an important role in the development of European water supply and contributes to drinking-water production substantially. This development has occurred autonomously, with "trial-and-error" within the full range of climatically and hydrogeologically diverse conditions of the European countries. For the future, MAR has the potential to facilitate optimal (re)use and storage of available water resources and to take advantage of the natural purification and low energy requirements during MAR operations. Particularly with respect to the re-use of wastewater treatment-plant effluent and stormwater, which is currently underdeveloped, the use of MAR can support the public acceptance of such water-resource efficient schemes. Particularly for the highly productive and urbanized coastal zones, where the pressure on freshwater supplies increases by growing water demand, salinization and increased agricultural needs for food production (such as along the Mediterranean and North Sea coasts), MAR is expected to be increasingly relied on in Europe.

  18. Current Situation in Occupational Health and Safety Education in Higher Education Institutions of Turkey

    Directory of Open Access Journals (Sweden)

    Osman SİVRİKAYA

    2016-10-01

    Full Text Available During recent years, “the occupational health and safety” topic, which has gained importance in different countries in the world, has got attention in Turkey as well. The importance of human life and health is being increased in the world especially in the developed countries. As a result of this, in order to prevent the work accidents involving death or personal injury in the work life, the importance of the “occupational health and safety” is increasing gradually. In Turkey, the regulation studies are being carried out on this topic with the successive regulations especially during recent years. The application aspect of the topic, which is related to employers on the occasion of legal liabilities in accordance with the regulations, and for the graduates who are seeking for a job and especially want to be occupational safety specialists, it is popular from the point of view to be hope for a job. However, due to the difficulties to follow the rapidly changing developments, efficient awareness about the topic is not possible. It is possible that to get true and current information about the topic is possible by showing necessary sensitivity about occupational health and safety education. The graduates from different departments wonder the topics such as what is “occupational health and safety” education and “what kind of an education is necessary to become an occupational safety specialist”. Hence, in this article, by giving current information about occupational health and safety education and their content in the higher education institutions in Turkey, the points, which have had improvements compared to the past, are considered, and certain suggestions are presented to have better occupational health and safety education.

  19. THE SOCIAL ENTERPRISE IN ROMANIA. AN EUROPEAN PERSPECTIVE ON THEIR CURRENT SITUATION

    Directory of Open Access Journals (Sweden)

    Vinke Joop

    2012-12-01

    Full Text Available The current paper is aimed at identifying the social enterprises according to EMES criteria by investigating the social economy actors in Romania. As an emerging field of study, social entrepreneurship and social enterprise have captured the attention of both practitioners from Europe and North America, and in recent years on other continents. In Romania, very little research has been conducted into the field, mostly as part of academic research papers from doctoral study students or masters, both from Romania and abroad. In Europe, several studies have been conducted among member state of the European Union, to bring to light this new emerging field.. Investigations in regard to social entrepreneurship in Europe have revealed the existence of this field among social economy actors, in the form of social enterprise, namely work integration social enterprises and social cooperatives. So far, Romania has not been included in them This papers tries to fill the gap of knowledge on this phenomena, by exploring, from a European perspective, the actors of social entrepreneurship in Romania. The methodology used was an analysis of secondary data in the form of legal documents (laws, reports of the social economy sector and scholarly articles related to social entrepreneurship in Romania. The assessment instrument is the EMES set of economic and social criteria that the social enterprises need to meet. Also, parallels have been made with the entities of the same nature in the European Union. The paper concludes on the state of social enterprise in Romania, with an underline on what its and implications for their further study. As main finding, two types of organizations fit best with the EMES criteria, authorized protected units and companies set up by associations and foundations. Also, further developments are expected as Romania is preparing for a law defining the social enterprise and social economy. The main implications of this research is drawing

  20. Current hepatitis B virus infection situation in Indonesia and its genetic diversity.

    Science.gov (United States)

    Lusida, Maria Inge; Juniastuti; Yano, Yoshihiko

    2016-08-28

    Indonesia has a moderate to high endemicity of hepatitis B virus (HBV) infection. The risk for chronic HBV infection is highest among those infected during infancy. Since 1997, hepatitis B (HepB) vaccination of newborns has been fully integrated into the National Immunization Program. Although HBV infection has been reduced by the universal newborn HepB immunization program, it continues to occur in Indonesia. The low birth dose coverage and the presence of vaccine escape mutants might contribute to this endemicity among children. Although limited information is available for an analysis of occult HBV infection (OBI), several variations and substitutions in the pre-S/S region have been detected in Indonesian HBV strains. Additionally, persistent infection and disease progression of chronic hepatitis B are related to not only viral factors but also the host genome. Indonesia is one of the most ethnically heterogeneous nations, with Javanese and Sundanese as the two highest ethnic groups. This multi-ethnicity makes genomic research in Indonesia difficult. In this article, we focused on and reviewed the following aspects: the current hepatitis B immunization program and its efficacy, OBI, HBV infection among high-risk patients, such as hemodialysis patients, and research regarding the host genome in Indonesia.

  1. [Current situation of human resources of parasitic disease control and prevention organizations in Henan Province].

    Science.gov (United States)

    Ya-Lan, Zhang; Yan-Kun, Zhu; Wei-Qi, Chen; Yan, Deng; Peng, Li

    2018-01-10

    To understand the current status of human resources of parasitic disease control and prevention organizations in Henan Province, so as to provide the reference for promoting the integrative ability of the prevention and control of parasitic diseases in Henan Province. The questionnaires were designed and the method of census was adopted. The information, such as the amounts, majors, education background, technical titles, working years, and turnover in each parasitic disease control and prevention organization was collected by the centers for disease control and prevention (CDCs) at all levels. The data were descriptively analyzed. Totally 179 CDCs were investigated, in which only 19.0% (34/179) had the independent parasitic diseases control institution (department) . There were only 258 full-time staffs working on parasitic disease control and prevention in the whole province, in which only 61.9% (159/258) were health professionals. Those with junior college degree or below in the health professionals accounted for 60.3% (96/159) . Most of them (42.1%) had over 20 years of experience, but 57.9% (92/159) of their technical post titles were at primary level or below. The proportion of the health professionals is low in the parasitic disease control and prevention organizations in Henan Province. The human resource construction for parasitic disease control and prevention at all levels should be strengthened.

  2. BETWEEN EUROPEANIZATION, UNITARISM AND AUTONOMY. REMARKS ON THE CURRENT SITUATION OF FEDERALISM IN AUSTRIA

    Directory of Open Access Journals (Sweden)

    Peter Bußjäger

    2010-04-01

    Full Text Available The following article describes current challenges of Austrian federalism. On ground of the Federal Constitution from 1920 Austria is a federation with nine autonomous Länder. Federalism is one of the basic principles of the constitution. Nevertheless the Länder are faced with centralizing drive due to Europeanization and unitarism. On the other hand the Länder have a strong regional identity. The Länder are emotionally deeply rooted in theAustrian population. The Länder also participate well in the decision making process on European level.Nevertheless the division of competencies both in legislation and administration between Federation and Länder is complicated and needs to be modernised. In the past various reform projects on federal level had failed while various reforms in the Land constitutions have led to more innovation on Land level. Despite these facts paradigms of reform debates on Austria´s federal system have changed: Until the early nineties of 20th century constitutionalreforms aimed to strengthen the role of the Länder. Since Austria´saccession to the EU reform projects the efficiency of the federal structures of Austria are doubted. Economical and financial crisis probably will increase the pressure for structural reforms.

  3. [E-health within the Dutch mental health services: what is the current situation?].

    Science.gov (United States)

    Smeets, Odile; Martin Abello, Katherina; Zijlstra-Vlasveld, Moniek; Boon, Brigitte

    2014-01-01

    The 'e-mental health' currently available, which also covers m-health and i-health, varies from psycho-education and self-tests to self-help, treatment and contact with fellow sufferers. Many programs are based on cognitive behavioural therapy, but other types of therapy are also used. Research shows that online programs for depression, alcohol problems and anxiety can reduce these symptoms and can be cost effective. This applies to both self-help and treatment programs. Many e-programs in the Netherlands have been developed for the Dutch Association of Mental Health and Addiction Care (GGZ) and for treatment of addiction problems. One problem with e-mental-health is that provision is fragmented, and there is no national overview, while insight into quality is important for patients and professionals. The quality hallmark 'Onlinehulpstempel.nl' ('Online help hallmark') provides this insight. The use of e-mental-health within Dutch healthcare services is still in its infancy. New financing methods are stimulating general practitioners to use it. The consolidation of online and face-to-face care ('blended e-health') provides an opportunity for patients and GGZ support personnel within general practice to start to use e-health.

  4. New tools, technology and techniques applied in geological sciences: current situation and future perspectives

    International Nuclear Information System (INIS)

    Ulloa, Andres

    2014-01-01

    Technological tools and work methodologies most used in the area of geological sciences are reviewed and described. The various electronic devices such as laptops, palmtops or PDA (personal digital assistant), tablets and smartphones have allowed to take field geological data and store them efficiently. Tablets and smartphones have been convenient for data collection of scientific data by the diversity of sensors that present, portability, autonomy and the possibility to install specific applications. High precision GPS in conjunction with LIDAR technology and sonar technology have been more accessible and used for geological research, generating high resolution three-dimensional models to complement geological studies. Remote sensing techniques such as high penetration radar are used to perform models of the ice thickness and topography in Antarctic. Modern three-dimensional scanning and printing techniques are used in geological science research and teaching. Currently, the advance in the computer technology has allowed to handle three-dimensional models on personal computers efficiently way and with different display options. Some, of the new areas of geology, emerged recently, are mentioned to generate a broad panorama toward where can direct geological researches in the next years [es

  5. Current Issues and Situation of Producer Responsibility in Waste Management in Indonesia

    Directory of Open Access Journals (Sweden)

    Antonius Priyo Nugroho Sulami

    2017-11-01

    Full Text Available Producer responsibility for wastes has been encouraged in Indonesia since 2008. The Ministry of Environment of the Republic of Indonesia also promoted the reduce, reuse, and recycle (3R concept using the community-based approach of waste banks integrated with the extended producer responsibility (EPR concept. However, related research and implementation are still limited. This study aims to identify the challenges of fulfilling producer responsibility in waste management and determine whether the integration concept could generate outcomes expected from the EPR concept. A semi-structured interview survey of several stakeholders from the government, industrial, and waste management sectors was conducted and the data generated was used to simulate an integration scheme using a system dynamics approach. Secondary data and information from Bandung municipality were used as input for the simulation. The interview survey found that the concerns and issues of fulfilling producer responsibility in waste management include lack of awareness, unavailability of clear guidelines, and the limited capacity of the current recycling sector. The results of the simulation suggested that if the integration scheme is applied, each business entity might bear the responsibility of IDR 29.4 million per year and 14.7 tons of waste per year for the scope of four sectors and IDR 34.1 million per year and 17 tons of waste per year for the scope of two sectors.

  6. An Overview of Hydropower Reservoirs in Brazil: Current Situation, Future Perspectives and Impacts of Climate Change

    Directory of Open Access Journals (Sweden)

    Viviane de Souza Dias

    2018-05-01

    Full Text Available Global climate change, related to the greenhouse gases emission, impacts hydroelectric power generation mainly due to the increase in air temperature and changes in the precipitation patterns. As a consequence, it affects basin evapotranspiration process, runoff, sediment transport as well as evaporation of reservoirs. This study analysed the current and future Brazilian context of hydroelectric reservoirs and investigated the potential impacts of climate change on hydropower generation and possible mitigation adjustments, giving relevant examples from around the world. Moreover, it is key to consider other factors that influence the availability of water resources such as: (a upstream development of reservoirs, mainly the development of agricultural systems, which can contribute to increased water demand; (b changes in land use, which can have an impact on soil degradation and sediment transport. Hydroelectric dams are a possible alternative to mitigate the impacts of climate change considering that those impacts could generate the need of adaptive actions. The assessment of climate change impacts’ projections anticipates possible future scenarios and can assist in strategic planning together with the definition of adaptive operational policies.

  7. Current Situation of Scientific Research at the University of Jordan from the Viewpoint of Graduate Students

    Directory of Open Access Journals (Sweden)

    Atif Omar Bin Tareef

    2017-05-01

    Full Text Available This study aimed to identify the current status of scientific research at the University of Jordan as perceived by graduate students and the differences between students of science and humanities faculties, and to identify their opinions regarding ways to improve scientific research at the University of Jordan. The study followed a descriptive methodology based on a survey that was developed specifically for the purpose of this study. The survey consisted of 40 items covering 5 themes, and was distributed to a sample of 104 male and female participants representing science and humanities faculties. The data were analyzed, using the two-way ANOVA, the standard deviation and means. In addition, students’ opinions and obstacles to effective participation of graduate students were categorized. The results showed significant differences between students’ assessment of the status of scientific research in science and humanities faculties, which was (3.2 for students in humanities faculties and (2.8 for students in science faculties. The difference also appeared in all the five domains of the scientific research, while there was no presence of gender effect, neither was there effect for the interaction between the variables (gender and the faculty. The study recommended to provide financial support to scientific research, and to establish a refereed scientific Journal for publishing students’ innovative ideas and research projects. Keywords: Scientific research, Graduate students.

  8. CURRENT SITUATION OF CIVIL AWARENESS OF UNDERGRADUATE AND PROMOTION STRATEGY RESEARCH

    Directory of Open Access Journals (Sweden)

    Li Hong-Mei

    2017-06-01

    Full Text Available We conducted on a questionnaire survey for the current college students’ civic awareness from four aspects of equality consciousness, national consciousness, freedom consciousness and public consciousness. Survey data was analyzed with the SAS® statistical software, the results shown that some of our country’s College Students with a strong national consciousness, and their patriotic feeling is deep at present. They identity the consciousness of equality, but their awareness of fighting for rights is not strong. They have a sense of freedom, but some students are not clear about the relationship between freedom and law. Their enthusiasm to participate in public affairs is not high. Their awareness of social morality is not comprehensive. The reason is that the influence of traditional culture and the political development can’t keep up with the development of economy and the systematic citizenship education is lacked. Finally, we put forward a method of improve the civic awareness of Contemporary College Students in this paper.

  9. Current situation and control measures of groundwater pollution in gas station

    Science.gov (United States)

    Wu, Qiong; Zhang, Xiaofeng; Zhang, Qianjin

    2017-11-01

    In recent years, pollution accidents caused by gas station leakage has occurred worldwide which can be persistent in groundwater. Numerous studies have demonstrated that the contaminated groundwater is threatening the ecological environment and human health. In this article, current status and sources of groundwater pollution by gas station are analyzed, and experience of how to prevent groundwater pollution from gas stations are summarized. It is demonstrated that installation of secondary containment measures for the oil storage of the oil tank system, such as installation of double-layer oil tanks or construction of impermeable ponds, is a preferable method to prevent gas stations from groundwater pollution. Regarding to the problems of groundwater pollution caused by gas station, it is proposed that it is urgent to investigate the leakage status of gas station. Relevant precise implementation regulations shall be issued and carried out, and supervision management of gas stations would need to be strengthened. Then single-layer steel oil tanks shall be replaced by double-layer tanks, and the impermeable ponds should be constructed according to the risk ranking. From the control methodology, the groundwater environment monitoring systems, supervision level, laws and regulations as well as pollution remediation should also be carried out and strengthened.

  10. Psychotherapy in psychiatry: the current situation and future directions in Germany.

    Science.gov (United States)

    Schnell, Knut; Herpertz, Sabine C

    2011-11-01

    The aim of this article is to review how psychotherapy is dispensed to patients in psychiatric treatment and to render the future perspectives of psychotherapy in psychiatric outpatient and inpatient care in Germany. We demonstrate that--according to the currently available data about healthcare providers, allocation of financial resources and curricular regulations--the presently used definition of the term "psychotherapy" is ambiguous. One major problem for the application of psychotherapy in psychiatry is obviously constituted by the dominance of the major guideline therapies ("Richtlinienverfahren") within psychiatric services. Here, guideline therapies do not meet the needs of a significant proportion of acutely, severely and/or chronically ill psychiatric patients and restrain the application of scientifically approved, disorder-oriented and context compliant interventions in psychiatric practice. As a future perspective, we suggest that the training of psychiatrists should impart profound interpersonal skills and provide the competence to offer psychotherapy within a multimodal, modular, and flexible treatment plan on the background of the self-conception of psychiatry as a medical discipline. Moreover, future concepts of psychiatric psychotherapy should promote an evidence-based selection and application of scientifically approved, disorder-oriented, and integrative treatment methods, which are available in growing number.

  11. THE ASSESSMENT OF ENTREPRENEURIAL PERSONALITY: THE CURRENT SITUATION AND FUTURE DIRECTIONS

    Directory of Open Access Journals (Sweden)

    Javier Suárez-Álvarez

    2016-01-01

    Full Text Available Entrepreneurship is fundamental in modern society because it represents an important source of innovation, employment, productivity, and growth. While the first theoretical models arose from economic and sociological approaches, psychology provides models that integrate different aspects such as cognitions, attitudes and personality, which allow a more detailed study. The purpose of this paper is to show the main contributions of psychology to the assessment of the enterprising personality. For this purpose, the main models and instruments developed to date were reviewed. The results confirm that the enterprising personality has a multidimensional structure and eight personality traits can be highlighted: achievement motivation, risk-taking, autonomy, self-efficacy, stress tolerance, innovativeness, internal locus of control, and optimism. From a methodological point of view, Item Response Theory and Computerised Adaptive Tests represent the most advanced and modern methods for assessing enterprising personality. There are currently several measurement instruments available. Future areas of research should be directed at the construction of multidimensional models as well as providing alternatives that facilitate a reduction in social desirability and other biases inherent in self-reports.

  12. [100 years of drinking water regulation. Retrospective review, current situation and prospects].

    Science.gov (United States)

    Rakhmanin, Yu A; Krasovsky, G N; Egorova, N A; Mikhailova, R I

    2014-01-01

    There is considered the history of the development of legislative requirements to the regulation of the quality of drinking water in different countries and international organizations during the period from 1912 to the present time. In terms of comparative analysis there is analyzed the current state of regulatory frameworks of the Russian Federation, WHO, EU, Finland, the UK, Singapore, Australia, Japan, China, Nigeria, the United States and Canada in the field of providing favorable conditions of population drinking water use. There has been noted the significant progress in standardization of the content of the biogenic elements and chemical pollution of drinking water in the absence of uniform requirements to the composition and properties of drinking water globally, that is bound to the need to take into account the national peculiarities of drinking water supply within the separate countries. As promising directions for improving regulation of drinking water quality there are noted: the development of new standards for prioritized water pollution, periodic review ofstandards after appearance of the new scientific data on the biological action of substances, the use of the concept of risk, the harmonization of the normative values and the assessment of the possibility of introduction into the practice the one more criterion of profitableness of population water use--the bioenergetic state of the water.

  13. General Technical Approvals for Decentralised Sustainable Urban Drainage Systems (SUDS—The Current Situation in Germany

    Directory of Open Access Journals (Sweden)

    Carsten Dierkes

    2015-03-01

    Full Text Available The use of decentralised, sustainable urban drainage systems (SUDS for the treatment of stormwater runoff is becoming increasingly prevalent in Germany. Decentralised SUDS can offer a viable and attractive alternative to end of pipe treatment systems for stormwater runoff from urban areas. However, there is still some uncertainty regarding the long-term performance of SUDS, and the general legislative requirements for SUDS approval and testing. Whilst the allowable pollution levels in stormwater runoff that infiltrate into ground and/or water table are regulated across Germany by the Federal Soil Protection Law, there is presently no federal law addressing the discharge requirements for surface water runoff. The lack of clear guidance can make it difficult for planners and designers to implement these innovative and sustainable stormwater treatment systems. This study clarifies the current understanding of urban stormwater treatment requirements and new technical approval guidelines for decentralised SUDS devices in Germany. The study findings should assist researchers, designers and asset managers to better anticipate and understand the performance, effective life-spans, and the planning and maintenance requirements for decentralised SUDS systems. This should help promote even greater use of these systems in the future.

  14. Current situation, potentials and prospects for the development of organic farming in Šumadija

    Directory of Open Access Journals (Sweden)

    Brković Duško

    2016-01-01

    Full Text Available Šumadija is rich in natural potentials which provide a good basis for the future development of organic farming, given the fact that natural resources are limited. The composition and structure of natural resources are highly suitable for organic production. The region's relatively unpolluted land, favourable climate, abundant water resources and preserved biodiversity are some of the main organic farming requirements satisfied. Organic production is not possible without ensuring at least a minimum level of preservation of natural resources in areas where organic farming is practised; on the other hand, organic production itself has a positive effect on the preservation and improvement of environmental quality in these areas. Small plots of land can be advantageous for this production, particularly in upland areas, and used specifically for organic production as the conversion period is short. They can be used for vegetable farming because the soil is uncontaminated owing to distance from roads. Positive experience indicates that potatoes, rye, oats and root vegetables can be successfully grown in these areas. Another advantage is the wealth of indigenous cultivars of apples, pears and plums which are highly resistant to pathogenic pests and environmental conditions, and hence suitable for cultivation without the use of mineral fertilisers and chemical agents. Major issues currently facing organic farming are a small-scale organic market and low prices of organic products, a low level of consumer awareness of the advantages of organic farming, suspicion and ignorance, low purchasing power, low availability of organic products through sales channels, etc.

  15. Current situation of the project finishing of the building of 3 and 4 block of the nuclear power plant Mochovce

    International Nuclear Information System (INIS)

    Niznan, S.

    2005-01-01

    In the contribution there is the basic information mentioned about history of building and the current situation at the finishing of the building of 3 and 4 block of the Nuclear Power Plant Mochovce with the use of project digitization. Further on the contribution shows what kinds of supporting material has been elaborated, what kind of decisions have been issued to the finishing of the building, way of financing and also the assumption of investment return under the defined conditions. An orientation time schedule of the finishing of the building and the crucial steps for its security are presented in the conclusion

  16. Labeling programs and efficiency standards to control the energy consumption of household appliances: current situation, main results and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, Ph.

    2000-09-01

    To control the rise in electricity consumption for specific uses, the industrialized countries started by introducing special programs aimed at improving energy efficiency. Among the different instruments available, labeling programs and minimum energy performance standards (MEPS) have proved to be very effective. The first part of this document presents the current situation, the main results and recommendations concerning the labeling programs and efficiency standards to control the energy consumption of household appliances. This analyze is done for each country in details providing the name of the program or measure, the date of implementation, the objective and the main characteristics of the program, the impacts and evaluation. (A.L.B.)

  17. The Current Situation of ICT Development in the Middle East and ICT Support Policies. The Case of Syrian Arab Republic.

    Directory of Open Access Journals (Sweden)

    Tatsuya Yamamoto

    2004-04-01

    Full Text Available The purpose of this paper is to examine how ICT development is progressing and what kind of political and social effects have been occurring (or could occur in the near future in Middle Eastern Arabic countries. To examine this theme, this paper will adopt the Syrian Arab Republic as a case. To understand the Syrian government's policy toward the ICT development, it is necessary to examine the domestic political situation, since they are closely related. Under the Bashar Al- Asad's regime, we can confirm several reasons why they have to move forward on their ICT development policy and why it has become a crucial issue, which they cannot evade, as they had done under the previous regime, Hafez Al- Asad's regime. The situation that the Syrian government is facing right now is known by the term, "Dictator's Dilemma". This paper tries to provide bases in order to examine and explore this dilemma in Syria. Also, when we examine ICT development in Syria, it is important to consider the ICT support policies, which are mainly conducted by OECD countries and international organizations and stem from the issue of "Digital Divide". This is why international assistances could have great effect on ICT development in Syria. As a provisional conclusion of this paper, I will summarize how we can understand the current situation of ICT development in Syria, and I will also comment on the future prospect of the dilemma that the Syrian government is facing at the present time.

  18. [Out-of-hours primary care in Germany: general practitioners' views on the current situation].

    Science.gov (United States)

    Frankenhauser-Mannuß, J; Goetz, K; Scheuer, M; Szescenyi, J; Leutgeb, R

    2014-07-01

    The aim of this study was to explore views, experiences und perspectives of German GPs related to current out-of-hours service provision covering both urban and rural settings. In the context of the international project EurOOHnet (European Research Network for Out-of-Hours Primary Health Care) the German members (of EurOOHnet) developed a questionnaire about organisational structures, infrastructure requirements and the procedures of information flow between regular care and out-of-hours care in 2011. This questionnaire was adopted in every participating country. A comprehensive postal questionnaire was sent to 410 feneral practice cooperatives in Germany. Qualitative content analysis and an inductive reasoning process, supported by the use of Atlas.ti, were used to identify key themes from responses to open-ended questions in the survey. Results were grouped into 3 overarching categories and each of these were grouped into 3 sub-categories. The questionnaire response rate was 44% (181/410). The analysis identified organisational issues (e. g., financing) and infrastructure barriers (e. g., lack of motivated GPs for out-of-hours care) as key themes. Significantly, different priorities between rural and urban GPs were identified. In particular, rural GPs highlighted shortages of GPs and distance between the GP practice and patients' residence as concerning factors impacting on out-of-hours care. Based on reported views from survey respondents, urban and rural primary care service needs vary significantly and, therefore, different solutions are needed to improve out-of-hours primary care and optimise service quality. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Nutrition situation in Latin America and the Caribbean: current scenario, past trends, and data gaps

    Directory of Open Access Journals (Sweden)

    Luis Galicia

    Full Text Available ABSTRACT Objective To determine the current nutritional status in Latin America and the Caribbean (LAC and identify data gaps and trends in nutrition surveillance. Methods A systematic Internet search was conducted to identify official sources that allowed for monitoring of LAC countries’ nutritional status, including progress toward World Health Organization Global Nutrition Targets 2025. Reports from national nutrition surveillance systems and reports on nationally representative surveys were collected and collated to 1 analyze nutritional status, based on life-course anthropometric indicators and biomarkers, and 2 identify gaps in data availability and trends in nutritional deficiencies. Information on iron, vitamin A, iodine, folate, and vitamin B12 deficiency was also collected and collated. Results Twenty-two of the 46 LAC countries/territories (48% had information on undernutrition (stunting, underweight, and wasting in children under 5 years old and women of reproductive age (WRA. Seventeen countries (38% had information on anemia in children under 5 years old and WRA, and 12 (27% had information on anemia in pregnant women. Although overall nutritional status has improved in the past few decades in all countries in the region, some LAC countries still had a high prevalence of stunting and anemia in children and WRA. Overweight affected at least 50% of WRA in nine countries with available data, and was increasing in children. Data for school-age children, adolescents, adult males, and older adults were scarce in the region. Conclusions Overall nutritional status has improved in the LAC countries with available information, but more efforts are needed to scale up nutrition-sensitive and nutrition-specific interventions to tackle malnutrition in all its forms, as stunting, anemia, and vitamin A deficiency are still a public health problem in many countries, and overweight is an epidemic. Nutrition information systems are weak in the

  20. Courts of customary law in the post-soviet states: history and the current situation

    Directory of Open Access Journals (Sweden)

    Сергій Володимирович Васильєв

    2016-01-01

    Full Text Available Problem setting and relevance of the research topic. Research of courts of customary law is not a new trend in the domestic legal science. However, it should be noted that this issue was covered mainly in the historical and ethnographic aspect, and, as a rule, in relation to specific countries or peoples. Taking into account the fact that in some post-Soviet states the rules of the customary law have remained and take effect even under the current conditions, there is a need to study people’s judgment on the basis of historical experience, taking into account the fact that there is no special scientific research on this subject. Paper objective. On the basis of studying the courts of customary law that existed in the territory of the post-Soviet states, to reveal their diversity, special features and peculiarities of formation and to analyze the contemporary forms of the aforementioned courts. Paper main body. The courts of customary law existed in various nations and nationalities since ancient times. The identity of one or another traditional court depended on such facts as the territorial location of the community, the level of economic and cultural development, type of religion, etc. In this paper the organization of the traditional justice of post-Soviet states in the second half of the XIX century was studied, when the basic territorial boundaries of the Russian Empire were formed. It is within these boundaries the peoples lived, who subsequently became Soviet republics, and then independent states. The main characteristic features of traditional courts that existed in the territory of post-Soviet states have been emphasized (1 judicial procedure was not regulated in detail; (2 the rules of the customary law (adat rules were the basis of the justice; (3 members of the court were competent persons of the community; (4 the court was common for all members of the community; (5 disputes were resolved through reconciliation of the parties; (6

  1. Use and treatment of olive mill wastewater: current situation and prospects in Spain

    Directory of Open Access Journals (Sweden)

    Fiestas Ros de Ursinos, J. A.

    1992-04-01

    Full Text Available The characteristics of olive mill wastewater are set out the viewpoint of their pollutant capacity and the problems arising from their tipping in olive-growing areas. The national administration's solutions for preventing pollutions of surface waters are also stated. Special detail is given to the action taken within a research and development program financed by the Spanish Government and the EEC through the Commission MEDSPA 89 for the technical-economic evaluation of different systems for eliminating and treating olive mill wastewater, in order to determine the feasibility of their introduction at industrial level. At the same time the systems currently under evaluation are described: - Intensification of natural evaporation from olive mill wastewater stored in ponds (two systems. - Physical processes using forced evaporation to eliminate the olive mill wastewater, followed by aerobic biological processes or systems of ultrafiltration and inverse osmosis for final treatment of the condensate (two systems. - Application of physico-chemical processes to eliminate the greater part of the organic components of the olive mill wastewaters and the use of aerobic biological processes or systems of ultrafiltration and inverse osmosis for final treatment of the clarified fraction (three systems. - Biological process for the complete treatment of the olive mill wastewaters by the successive application of processes: bioconversion, biomethanisation, aerobic treatment, and physico-chemical treatment. Treatment yields of the order of 99,6% are achieved, at the same time obtaining by-products of commercial interest (one system.

    Las características de los alpechines se establecen desde el punto de vista de su capacidad contaminante y de los problemas típicos que surgen en las zonas de cultivo del olivo. También están descritas las soluciones de la administración del Estado para la prevención de la contaminación de aguas de superficie

  2. Physiotherapy and cardiac rhythm devices: a review of the current scope of practice.

    Science.gov (United States)

    Digby, Geneviève C; Daubney, Marguerite E; Baggs, Jim; Campbell, Debra; Simpson, Christopher S; Redfearn, Damian P; Brennan, F James; Abdollah, Hoshiar; Baranchuk, Adrian

    2009-07-01

    Several case reports have demonstrated negative interactions between various physiotherapy modalities and cardiac rhythm devices (CRD). Fear of these potential interactions may lead to suboptimal utilization of physiotherapy treatments in CRD patients. No prior review of available guidelines, or management strategies, on the interaction between physiotherapy modalities and CRD patients has been reported. To review existing guidelines regarding the use of physiotherapy modalities in patients with pacemakers and/or implantable cardioverter-defibrillators (ICDs). To retrospectively analyse CRD patient encounters at a local physiotherapy facility during a period of 2 years. A review of the literature regarding the potential interactions between physiotherapy modalities and CRDs was performed. Next, a 2 year retrospective analysis of patient encounters at a physiotherapy facility was conducted. In addition, seven international physiotherapy societies and four CRD manufacturers were surveyed with respect to recommendations regarding physiotherapy treatments in device patients. The local physiotherapy facility treated 25 patients with CRD (22 pacemaker and 3 ICD patients) for a total of 230 visits (9.2 visits/patient). Five patients received transcutaneous electrical nerve stimulation (TENS) and all 25 were administered additional treatment in the form of ultrasound (15), acupuncture (19), Laser (7), traction/manual therapy (12), exercise (8), education (18), taping (5), and/or moist heat (5). No complications occurred. Meanwhile, international societies and device manufacturers offered few specific or consistent recommendations. There are no specific international policies regarding the administration of physiotherapy modalities in CRD patients and, thus, there are no specific guidelines to be implemented at the local level. Review of the literature and of recommendations from CRD manufacturers suggests that TENS, Diathermy, and Interferential Electrical Current Therapy

  3. Slaughter of pregnant cattle in German abattoirs--current situation and prevalence: a cross-sectional study.

    Science.gov (United States)

    Maurer, Patric; Lücker, Ernst; Riehn, Katharina

    2016-06-07

    The slaughter of pregnant cattle and the fate of the foetuses are relatively new subjects in the field of animal welfare. The Scientific Committee on Veterinary Measures relating to Public Health (SCVPH), however, does not believe this topic to be a critical issue because of the hitherto supposed rare occurrence of this practice. Some previous studies though, contradict this assessment, emphasising its relevance to animal welfare. With regard to the heterogeneous study design of previous investigations, the objective of this study is to evaluate the current situation concerning the slaughter of pregnant cattle in different German abattoirs. Additionally, the prevalence was assessed semi-quantitatively on the basis of a cross-sectional, voluntary and anonymous survey that was conducted amongst senior veterinary students of the University of Leipzig from 2010 until 2013. Of 255 evaluable questionnaires, 157 (63.6%) mention the slaughter of pregnant cattle, corresponding to 76.9% of all visited abattoirs. Slaughter of pregnant cattle is reported often (>10% of females) in 6 (3.8%), frequently (1-10% of females) in 56 (35.7%), and rarely (current situation is indispensable to ensure the high standards in animal welfare in Germany and Europe.

  4. [Survey on the current situation of the young neurologists in Spain: analysis of their current working stability and degree of social protection].

    Science.gov (United States)

    Arenillas, J F; Cisteré, V; Bonaventura, I; Coll-Cantí, J; Luquin, M R; Martínez-Vila, E

    2006-03-01

    The aims of this study were to evaluate the working stability and degree of social protection of the Spanish young neurologists, and to know their opinion about their own situation. The 343 neurologists that became specialists in Spain between 2000 and 2004 were asked to participate in two consecutive surveys. The first, conducted online, included questions about the availability to change the place of work and the opinion about the situation of young neurologists, and obtained 66 answers. The second was a telephonic and online survey, answered by 217 neurologists, whose questions referred to: places of neurological education and work, type of working contract, and degree of social protection (estimated by the percentage of worked time during which they paid Social Security contributions). Sixty-three per cent (136/217) of the Spanish young neurologists had an unstable job. The most frequent unstable working contracts were: eventual (n=65; 31%), on-call contracts (n=54; 25%) and grants (n=53; 24%). Forty-eight per cent of the neurologists who ended their specialization in 2000 still remained working-unstable. The mean percentage of worked time with full social protection was 71.01+/-36.74%. Less than a half (n=101; 46%) had social protection during the entire worked time, 60 (28.6%) were socially protected during protection. A direct relationship was observed 68 between working instability and lower social protection (p=0.0002). The working situation of the Spanish young neurologists was seen as problematic by 97% of the 66 participants in the first survey. The current situation of the Spanish young neurologists, attending their working stability and degree of social protection, seems precarious and problematic. Urgent actions should be taken by the Administration to improve it.

  5. Association of current work and sleep situations with excessive daytime sleepiness and medical incidents among Japanese physicians.

    Science.gov (United States)

    Kaneita, Yoshitaka; Ohida, Takashi

    2011-10-15

    The aim of the present study was to clarify the current work and sleep situations of physicians in Japan and to clarify the association between these situations and excessive daytime sleepiness as well as medical incidents. A self-administered questionnaire survey was conducted among the members of the Japan Medical Association in 2008. The randomly selected subjects comprised 3,000 male physicians and 1,500 female physicians. Valid responses were obtained from 3,486 physicians (2,298 men and 1,188 women). Mean sleep duration was 6 h 36 min for men and 6 h 8 min for women. The prevalence of lack of rest due to sleep deprivation was 30.4% among men and 36.6% among women; the prevalence of insomnia was 21.0% and 18.1%, respectively; and the prevalence of EDS was 3.5%. The adjusted odds ratio for EDS was high for physicians who reported short sleep duration, lack of rest due to sleep deprivation, and a high frequency of on-call/overnight work. Physicians who had experienced a medical incident within the previous one month accounted for 19.0% of participants. The adjusted odds ratio for medical incidents was high for those subjected to long working hours, high frequency of on-call/overnight works, lack of rest due to sleep deprivation, and insomnia. In order to facilitate optimal health management for physicians as well as securing medical safety, it is important to fully consider the work and sleep situations of physicians.

  6. Control of zoonoses in emergency situations: lessons learned during recent outbreaks (gaps and weaknesses of current zoonoses control programmes

    Directory of Open Access Journals (Sweden)

    Darem Tabbaa

    2008-12-01

    Full Text Available In emergency situations, domestic animals and wildlife are, like people, exposed to infectious diseases and environmental contaminants in the air, soil, water and food. They can suffer from acute and/or chronic diseases from such exposure. Often animals serve as disease reservoirs or early warning systems for the community in regard to the spread of zoonotic diseases. Over 100 years of experience have shown that animal and human health are closely related. During the past few years, emergent disease episodes have increased; nearly all have involved zoonotic agents. As there is no way to predict when or where the next important new zoonotic pathogen will emerge or what its ultimate importance might be, investigation at the first sign of emergence of a new zoonotic disease is particularly important. Today, in many emerging situations, different activities involving zoonotic disease control are at risk because of failed investigative infrastructures or financial constraints. Considering that zoonotic diseases have their own characteristics, their prevention and control require unique strategies, based more on fundamental and applied research than on traditional approaches. Such strategies require cooperation and coordination between animal and public health sectors and the involvement of other disciplines and experts such as epidemiologists, entomologists, environmentalists and climatologists. Lessons learned from the avian influenza pandemic threat, the Crimean-Congo haemorrhagic fever and rabies outbreaks are presented and the gaps and weakness of current control programmes are discussed.

  7. Mansonella ozzardi and its vectors in the New World: an update with emphasis on the current situation in Haiti.

    Science.gov (United States)

    Raccurt, C P

    2017-10-25

    Mansonella ozzardi (Nematoda: Onchocercidae) is a little studied filarial nematode. This human parasite, transmitted by two families of dipteran vectors, biting midges (most of them members of the genus Culicoides) and blackflies (genus Simulium), is endemic to the Neotropical regions of the New World. With a patchy geographical distribution from southern Mexico to north-western Argentina, human infection with M. ozzardi is highly prevalent in some of the Caribbean islands, along riverine communities in the Amazon Basin, and on both sides of the border between Bolivia and Argentina. Studies conducted in Haiti between 1974 and 1984 allowed the first complete description of the adult worm and permitted clarification of the taxonomic position of this filarial species. This paper reports the known geographical distribution of M. ozzardi in Neotropical regions of the Americas, and focuses on the current situation in Haiti where this filariasis remains a completely neglected public health problem.

  8. In search of critically endangered species: the current situation of two tiny salamander species in the Neotropical mountains of Mexico.

    Directory of Open Access Journals (Sweden)

    Adriana Sandoval-Comte

    Full Text Available Worldwide, one in every three species of amphibian is endangered, 39 species have gone extinct in the last 500 years and another 130 species are suspected to have gone extinct in recent decades. Of the amphibians, salamanders have the highest portion of their species in one of the risk categories, even higher than the frogs. To date there have been few studies that have used recent field data to examine the status of populations of endangered salamanders. In this study we evaluate the current situation of two tiny salamanders, Parvimolge townsendi and Thorius pennatulus, both of which are distributed at intermediate elevations in the mountains of the northern Neotropics and are considered to be critically endangered; the first has been proposed as possibly extinct. By carrying out exhaustive surveys in both historical and potentially suitable sites for these two species, we evaluated their abundance and the characteristics of their habitats, and we estimated their potential geographic distribution. We visited 22 sites, investing 672 person-hours of sampling effort in the surveys, and found 201 P. townsendi salamanders in 11 sites and only 13 T. pennatulus salamanders in 5 sites. Both species were preferentially found in cloud forest fragments that were well conserved or only moderately transformed, and some of the salamanders were found in shade coffee plantations. The potential distribution area of both species is markedly fragmented and we estimate that it has decreased by more than 48%. The results of this study highlight the importance of carrying out exhaustive, systematic field surveys to obtain accurate information about the current situation of critically endangered species, and help us better understand the crisis that amphibians are facing worldwide.

  9. Large-scale integration of renewable and distributed generation of electricity in Spain: Current situation and future needs

    International Nuclear Information System (INIS)

    Cossent, Rafael; Gómez, Tomás; Olmos, Luis

    2011-01-01

    Similar to other European countries, mechanisms for the promotion of electricity generation from renewable energy sources (RESs) and combined heat and power (CHP) production have caused a significant growth in distributed generation (DG) in Spain. Low DG/RES penetration levels do not have a major impact on electricity systems. However, several problems arise as DG shares increase. Smarter distribution grids are deemed necessary to facilitate DG/RES integration. This involves modifying the way distribution networks are currently planned and operated. Furthermore, DG and demand should also adopt a more active role. This paper reviews the current situation of DG/RES in Spain including penetration rates, support payments for DG/RES, level of market integration, economic regulation of Distribution System Operators (DSOs), smart metering implementation, grid operation and planning, and incentives for DSO innovation. This paper identifies several improvements that could be made to the treatment of DG/RES. Key aspects of an efficient DG/RES integration are identified and several regulatory changes specific to the Spanish situation are recommended. - Highlights: ► Substantial DG/RES penetration levels are foreseen for the coming years in Spain. ► Integrating such amount of DG/RES in electricity markets and networks is challenging. ► We review key regulatory aspects that may affect DG/RES integration in Spain. ► Several recommendations aimed at easing DG/RES integration in Spain are provided. ► Market integration and the transition towards smarter grids are deemed key issues.

  10. In search of critically endangered species: the current situation of two tiny salamander species in the Neotropical mountains of Mexico.

    Science.gov (United States)

    Sandoval-Comte, Adriana; Pineda, Eduardo; Aguilar-López, José L

    2012-01-01

    Worldwide, one in every three species of amphibian is endangered, 39 species have gone extinct in the last 500 years and another 130 species are suspected to have gone extinct in recent decades. Of the amphibians, salamanders have the highest portion of their species in one of the risk categories, even higher than the frogs. To date there have been few studies that have used recent field data to examine the status of populations of endangered salamanders. In this study we evaluate the current situation of two tiny salamanders, Parvimolge townsendi and Thorius pennatulus, both of which are distributed at intermediate elevations in the mountains of the northern Neotropics and are considered to be critically endangered; the first has been proposed as possibly extinct. By carrying out exhaustive surveys in both historical and potentially suitable sites for these two species, we evaluated their abundance and the characteristics of their habitats, and we estimated their potential geographic distribution. We visited 22 sites, investing 672 person-hours of sampling effort in the surveys, and found 201 P. townsendi salamanders in 11 sites and only 13 T. pennatulus salamanders in 5 sites. Both species were preferentially found in cloud forest fragments that were well conserved or only moderately transformed, and some of the salamanders were found in shade coffee plantations. The potential distribution area of both species is markedly fragmented and we estimate that it has decreased by more than 48%. The results of this study highlight the importance of carrying out exhaustive, systematic field surveys to obtain accurate information about the current situation of critically endangered species, and help us better understand the crisis that amphibians are facing worldwide.

  11. Current situation of International Organization for Standardization/Technical Committee 249 international standards of traditional Chinese medicine.

    Science.gov (United States)

    Liu, Yu-Qi; Wang, Yue-Xi; Shi, Nan-Nan; Han, Xue-Jie; Lu, Ai-Ping

    2017-05-01

    To review the current situation and progress of traditional Chinese medicine (TCM) international standards, standard projects and proposals in International Organization for Standardization (ISO)/ technical committee (TC) 249. ISO/TC 249 standards and standard projects on the ISO website were searched and new standard proposals information were collected from ISO/TC 249 National Mirror Committee in China. Then all the available data were summarized in 5 closely related items, including proposed time, proposed country, assigned working group (WG), current stage and classifification. In ISO/TC 249, there were 2 international standards, 18 standard projects and 24 new standard proposals proposed in 2014. These 44 standard subjects increased year by year since 2011. Twenty-nine of them were proposed by China, 15 were assigned to WG 4, 36 were in preliminary and preparatory stage and 8 were categorized into 4 fifields, 7 groups and sub-groups based on International Classifification Standards. A rapid and steady development of international standardization in TCM can be observed in ISO/TC 249.

  12. The management of family agriculture in the municipality of Pinar del Río: a diagnosis of the current situation

    Directory of Open Access Journals (Sweden)

    Llamil Otero Hidalgo

    2017-07-01

    Full Text Available Family agriculture is of great importance to food self-sufficiency of the productive families and a generating source of local development. In this sense, its points of link with cooperative movement and other forms of social and solidary economy such as associations, foundations and mutualities, are obvious. The work was carried out in the municipality of Pinar del Rio, in order to characterize the current situation of the management process of family agriculture and its contribution to food and nutrition security, based on the analysis of primary and secondary sources of information to assess the actual state of the object of study. In the research were applied theoretical and empirical methods, including some techniques as the questionnaire, applied to different levels of decision regarding the structure of urban, suburban and family agriculture program, and surveys to small family farmers whose production units classified as courtyards and plots. Finally, the information obtained using the technique of triangulation, allowed to establish the main positive and negative aspects related to the management of family agriculture and its contribution to the food and nutrition security in the municipality selected.

  13. Current situation with the centralized storage facilities for non-power radioactive wastes in Latin American countries

    International Nuclear Information System (INIS)

    Benitez, Juan C.; Salgado, Mercedes; Idoyaga Navarro, Maria L.; Escobar, Carolina; Mallaupoma, Mario; Sbriz, Luciano; Moreno, Sandra; Gozalez, Olga; Gomez, Patricia; Mora, Patricia; Miranda, Alberto; Aguilar, Lola; Zarate, Norma; Rodriguez, Carmen

    2008-01-01

    Full text: Several Latin American (LA) countries have been firmly committed to the peaceful applications of ionizing radiations in medicine, industry, agriculture and research in order to achieve socioeconomic development in diverse sectors. Consequently the use of radioactive materials and radiation sources as well as the production of radioisotopes and labeled compounds may always produce radioactive wastes which require adequate management and, in the end, disposal. However, there are countries in the Latin American region whose radioactive waste volumes do not easily justify a national repository. Moreover, such facilities are extremely expensive to develop. It is unlikely that such an option will become available in the foreseeable future for most of these countries, which do not have nuclear industries. Storage has long been incorporated as a step in the management of radioactive wastes. In the recent years, there have been developments that have led some countries to consider whether the roles of storage might be expanded to provide longer-term care of long-live radioactive wastes The aim of this paper is to discuss the current situation with the storage facilities/conditions for the radioactive wastes and disused sealed radioactive sources in Latin-American countries. In some cases a brief description of the existing facilities for certain countries are provided. In other cases, when no centralized facility exists, general information on the radioactive inventories and disused sealed sources is given. (author)

  14. Current situation of energy consumption and measures taken for energy saving in the iron and steel industry in China

    International Nuclear Information System (INIS)

    Guo, Z.C.; Fu, Z.X.

    2010-01-01

    A survey of the key issues associated with the development in the Chinese iron and steel industry and current situations of energy consumption are described in this paper. The apparent production of crude steel in China expanded to 418.78 million tonnes in 2006, which was about 34% share of the world steel production. The iron and steel industry in China is still one of the major high energy consumption and high pollution industries, which accounts for the consumption of about 15.2% of the national total energy, and generation of 14% of the national total wastewater and waste gas and 6% of the total solid waste materials. The average energy consumption per unit of steel is about 20% higher than that of other advanced countries due to its low energy utilization efficiency. However, the energy efficiency of the iron and steel industry in China has made significant improvement in the past few years and significant energy savings will be achieved in the future by optimizing end-use energy utilization. Finally, some measures for the industry in terms of the economic policy of China's 11th five-year plan are also presented.

  15. [Current situation of pediatric emergency in tertiary and teaching hospitals in 15 provinces, municipalities and autonomous regions in China Mainland].

    Science.gov (United States)

    2014-12-01

    Pre-hospital care, emergency department and critical care medicine are the key components of emergency medical service system. Two investigations about the pediatric critical care medicine in China mainland showed great progress. In recent years, most hospitals in China mainland have established emergency department, hardware configuration and staff status were gradually standardized. But most of the emergency departments mainly provide service to adult patients and pediatric emergency medicine lags behind. The purpose of this investigation was to understand the current situation and main problems of pediatric emergency in China mainland. A questionnaire developed by the Subspecialty Group of Pediatrics, Chinese Society of Emergency Medicine and the Subspecialty Group of Emergency Medicine, Chinese Society of Pediatrics was e-mailed to the members of the above-mentioned two subspecialty groups. The contents of the questionnaire included 46 items which were divided into 5 categories: the general situation of the hospital, the pediatric emergency setting and composition, key equipments and techniques, staff status, training program and running data from 2011 to 2012. Sixty-three questionnaires were delivered and 27 (42.9%) hospitals responded which located in 15 different provinces, municipalities and autonomous regions. Among the 27 hospitals, 10 (37.0%) had no pediatric resuscitation room; 25 (92.6%) had no equipments for cardiac output monitor and gastric lavage; 13 (48.1%) had no bedside fibrolaryngoscope or fiberbronchoscope; 5 (18.5%) had no blood gas analyzer; 4 (14.8%) without respirator, defibrillator, bedside radiography or ultrasonic equipment; 2 (7.4%) had no neonatal incubator; 9 (33.3%) could not do intraossous infusion. The average ratio of professional emergency pediatricians to all physicians was 43.5%. Twenty hospitals incompletely filled in the pediatric emergency running data. The main problems existing in pediatric emergency include: imperfect

  16. Fowl adenovirus-induced diseases and strategies for their control - a review on the current global situation.

    Science.gov (United States)

    Schachner, Anna; Matos, Miguel; Grafl, Beatrice; Hess, Michael

    2018-04-01

    The stand-alone pathogenicity of fowl adenoviruses (FAdVs) had long been disputed, given the ubiquity of the viruses versus sporadic outbreaks, and variation between experimental studies. However, a globally emerging trend of FAdV-associated diseases has marked the past two decades, with hepatitis-hydropericardium syndrome mainly in Asia besides Arabian and Latin American countries, and geographically more disseminated outbreaks of inclusion body hepatitis. Finally, the appearance of FAdV-induced gizzard erosion (AGE) in Asia and Europe completed the range of diseases. Epidemiological studies confirmed serotype FAdV-4 as agent of hepatitis-hydropericardium syndrome, whereas inclusion body hepatitis is related to FAdV-2, -8a, -8b and -11. Members of the biologically more distant serotype FAdV-1 induce AGE. Urged by increasing problems in the field, numerous pathogenicity studies with FAdVs from outbreaks substantiated the primary aetiologic role of particular strains for distinct clinical conditions. Developments in the poultry industry towards highly specialized genetic breeds and rigorous biosecurity additionally contribute to the growing incidence of FAdV-related diseases. Confirming field observations, recent studies connected a higher susceptibility of broilers with their distinct physiology, implying the choice of bird type as a factor to be considered in infection studies. Furthermore, elevated biosecurity standards have generated immunologically naïve breeding stocks, putting broilers at risk in face of vertical FAdV transmission. Therefore, future prevention strategies should include adequate antibodies in breeders prior to production and - if necessary - vaccination, in order to protect progenies. This review aims to deliver a detailed overview on the current global situation about FAdV-induced diseases, their reproduction in vivo and vaccination strategies.

  17. Analysis of the current cost situation of wind power in Germany; Untersuchungen der aktuellen Kostensituation der Windenergienutzung in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Rehfeldt, K. [Deutsches Windenergie-Inst. Sucursal en Espana, Pamplona (Spain); Schwenk, B. [InnoVent GmbH, Varel (Germany)

    2000-07-01

    Against the background of the discussion concerning the Reimbursement Act (StrEG) and the draft Renewable Energy Sources Act (EEG), the Bundesverband Windenergie e.V. (BWE) asked the Deutsches Windenergie-Institut (DEWI) to investigate the current cost situation of wind power in Germany. This involved a statistics of wind power generation cost over a period of 20 years. The data were obtained from wind power system operators, technical experts, producers of wind power systems and insurance companies. It was found that especially the cost of component replacement was higher than expected, so that long component life must be one of the main goals in the further development of wind power systems. According to the technical experts, component life today is much less than the rated life of 20 years. [German] Vor dem Hintergrund der Diskussion um das Stromeinspeisegesetz (StrEG) bzw. des Neuentwurfs zum Erneuerbare-Energien-Gesetz (EEG) wurde das Deutsche Windenergie-Institut (DEWI) vom Bundesverband Windenergie e.V. (BWE) beauftragt, eine Studie ueber die aktuelle Kostensituation in Deutschland zu erarbeiten. Erstmals wurden hierbei Stromerzeugungskosten aus Windenergieanlagen (WEA) ueber einen Zeitraum von 20 Jahren ermittelt. Hierbei wurden Umfrageergebnisse von Betreibern von WEA, technischen Sachverstaendigen sowie von Herstellern von WEA und Versicherungsgesellschaften verwendet, um belastbare Aussagen ueber Betriebskosten und notwendige Ersatzinvestitionen zu erhalten. Insbesondere die Aussagen ueber notwendige Ersatzinvestitionen durch die technischen Sachverstaendigen waren hoeher als erwartet, so dass es in Zukunft Ziel sein muss, insbesondere bei der Weiterentwicklung von WEA auf wesentlich laengere Lebensdauern der Bauteilkomponenten von WEA zu draengen. Nach Aussage der technischen Sachverstaendigen liegen bisher die Lebensdauern wesentlicher Bauteile der WEA, wie Rotor, Bremssystem, Pitchregelung usw., weit unter der kalkulierten Lebensdauer von 20 Jahren

  18. Mental health care in Nepal: current situation and challenges for development of a district mental health care plan.

    Science.gov (United States)

    Luitel, Nagendra P; Jordans, Mark Jd; Adhikari, Anup; Upadhaya, Nawaraj; Hanlon, Charlotte; Lund, Crick; Komproe, Ivan H

    2015-01-01

    Globally mental health problems are a serious public health concern. Currently four out of five people with severe mental illness in Low and Middle Income Countries (LMIC) receive no effective treatment. There is an urgent need to address this enormous treatment gap. Changing the focus of specialist mental health workers (psychiatrists and psychologists) from only service delivery to also designing and managing mental health services; building clinical capacity of the primary health care (PHC) workers, and providing supervision and quality assurance of mental health services may help in scaling up mental health services in LMICs. Little is known however, about the mental health policy and services context for these strategies in fragile-state settings, such as Nepal. A standard situation analysis tool was developed by the PRogramme for Improving Mental health carE (PRIME) consortium to systematically analyze and describe the current gaps in mental health care in Nepal, in order to inform the development of a district level mental health care plan (MHCP). It comprised six sections; general information (e.g. population, socio-economic conditions); mental health policies and plans; mental health treatment coverage; district health services; and community services. Data was obtained from secondary sources, including scientific publications, reports, project documents and hospital records. Mental health policy exists in Nepal, having been adopted in 1997, but implementation of the policy framework has yet to begin. In common with other LMICs, the budget allocated for mental health is minimal. Mental health services are concentrated in the big cities, with 0.22 psychiatrists and 0.06 psychologists per 100,000 population. The key challenges experienced in developing a district level MHCP included, overburdened health workers, lack of psychotropic medicines in the PHC, lack of mental health supervision in the existing system, and lack of a coordinating body in the Ministry

  19. Poly- and perfluoroalkyl substances (PFASs) in raw and drinking water - current situation in Sweden, Denmark and Germany

    Science.gov (United States)

    Banzhaf, Stefan; Bester, Kai; Filipovic, Marko; Lewis, Jeffrey; Licha, Tobias; Sparrenbom, Charlotte; Barthel, Roland

    2016-04-01

    Poly- and perfluoroalkyl substances (PFASs) are a group of anthropogenic environmental pollutants which have been used and produced for more than 60 years. PFASs are used for multiple industrial purposes, e.g. as water repellent on clothing, leather, and paper and as firefighting foam. The most well studied PFASs subgroup are perfluoroalkyl acids (PFAA). Two PFAAs of particular interest are perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). These are the most studied homologues which are ubiquitously detected in the aquatic environment, wildlife and humans. Some PFASs are recognized as being potentially toxic for both animals and humans (e.g. PFOS), whereas the majority has not been thoroughly studied yet regarding their toxicity. PFAAs are highly mobile once present in the aquatic environment. Currently, they are not eliminated during conventional wastewater or drinking water treatment and therefore pose a severe threat for drinking water supply. We reviewed the current occurrence of PFAAs in the surface and groundwater and legal situation of PFAAs in Sweden, Denmark and Germany. Although first detections of PFAAs were reported in the early 2000s, PFASs only recently attracted huge media attention raising public concern. In Sweden, for instance, several public waterworks needed to cease operation due to high PFASs concentrations in drinking water. Moreover, threshold values for drinking water are under discussion and a first preliminary guiding value for PFOS was recently presented as a first step (Pettersson et al., 2015). Germany only defined a guiding value for the sum of PFOS and PFOA in drinking water so far (Dieter, 2011). Limits of 0.3 μg/L PFOA and 0.1 μg/L PFOS and PFOSA each have been suggested in Denmark (MST, 2015). In summary, none of the three countries has defined a clear threshold value for any PFAS compound in drinking water so far. This is of huge concern as PFASs are detected at increasing rates while it remains unclear when

  20. The accident at TEPCO's Fukushima Dai-ichi Nuclear Power Station - occurrence of the accident, current situation and Future

    International Nuclear Information System (INIS)

    Hirose, K.

    2013-01-01

    In this presentation author analyse course of accident on Fukushima Dai-chi NPPs as well as consequences of this disaster. The following parts are presented: (1) Occurrence of the accident; (2) Evacuation of the residential people; (3) Deterioration and protraction of the accident; (4) Impact on society; (5) Situation of decontamination; (6) Long-term steps towards decommissioning; (7) Situation of other nuclear power stations; (8) Conclusions and lessons learned.

  1. Current situation regarding the co-combustion of waste materials in power plants; Aktuelle Situation der Mitverbrennung von Abfallstoffen in Kraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, U.; Krueger, H.; Puch, K.H. [VGB Technische Vereinigung der Grosskraftwerksbetreiber e.V., Essen (Germany)

    1998-09-01

    In view of the wholly insufficient capacity, relative to current arisings, of waste incineration plants, residue processing plants and plants for the utilisation of other combustible materials we are inevitably faced with the question whether power plant furnaces might not be suited for the thermal treatment and utilisation of wastes and residues. This possibility has been studied by many VGB member companies and seriously investigated for its practicability in several cases. The investigations were premised on the following fundamental positions. The VGB members are prepared to contribute to the solution of the above problems as long as this is possible without detriment to their duties as energy suppliers. They can only assume this responsibility if the requirements of the licensing laws are observed. This concerns the quality and arising quantities of wastes to be taken in, emissions, and the disposal of combustion residues. Power plants typically make more or less complete use of their own process residues, a feature which as far as possible should not be impaired by the co-combustion process. The technical problems posed by the co-combustion of suitable residues and wastes are usually solvable. Co-combustion offers an alternative and a supplement to dedicated waste utilisation plants or plants for the utilisation of suitable residues. Beyond this some companies are interested in profiting from the fees that will be due to them for utilising wastes. From 1990 to 1992 a VGB working group studied the option of co-combustion on the basis of the above premises. The material elaborated by the group now in turn serves as a basis for the following deliberations. [Deutsch] Da die Kapazitaet der Abfallverbrennungsanlagen, der Anlagen zur Reststoffverwertung und der Anlagen zur Nutzung sonstiger brennbaren Stoffe fuer das vorhandene Angebot bei weitem nicht ausreicht, ergibt sich die Frage der Eignung von Kraftwerksfeuerungen zur thermischen Behandlung und Verwertung von

  2. 韩国食用菌产业发展现状与趋势%Korean Edible Fungi Industry Development Current Situation and Trend

    Institute of Scientific and Technical Information of China (English)

    韩德贤; 刘姿彤; 史磊; 王延锋; 盛春鸽; 董雪梅

    2014-01-01

    Korean edible fungi cultivation history ,cultivar ,production mode ,production status and current situation of trade are described by Korean edible fungi industry development current situ-ation in this page .It is analysised Korean edible fungi industry trend in development .%从韩国食用菌栽培历史、栽培品种、生产模式、生产现状及贸易现状等5个方面,阐述了韩国食用菌产业发展现状,并分析了韩国食用菌产业发展趋势。

  3. Experimental Section: On the magnetic field distribution generated by a dipolar current source situated in a realistically shaped compartment model of the head

    NARCIS (Netherlands)

    Meijs, J.W.H.; Bosch, F.G.C.; Peters, M.J.; Lopes da silva, F.H.

    1987-01-01

    The magnetic field distribution around the head is simulated using a realistically shaped compartment model of the head. The model is based on magnetic resonance images. The 3 compartments describe the brain, the skull and the scalp. The source is represented by a current dipole situated in the

  4. A Pregnancy with Severe Hypertrophic Obstructive Cardiomyopathy after Surgery for an Implantable Cardioverter Defibrillator: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Takashi Mitsui

    2016-01-01

    Full Text Available Hypertrophic obstructive cardiomyopathy (HOCM is cardiac hypertrophy of ventricular myocardium with left ventricular outflow tract obstruction. We report a pregnancy with HOCM after defibrillator implantation surgery. The patient was a 33-year-old nulligravida and was categorized as New York Heart Association class II. Her brain natriuretic peptide (BNP level was 724.6 pg/dL at preconception. She received careful pregnancy management. However, because frequent uterine contractions were observed at 25 weeks and 6 days of pregnancy, she was hospitalized, and magnesium sulfate was started as a tocolytic agent. At 27 weeks and 5 days of pregnancy, she had respiratory discomfort and orthopnea with a sudden decrease in peripheral oxygen saturation. Cardiac ultrasonography showed a worsened condition of HOCM and her BNP level was 1418.0 pg/mL. We performed an emergent cesarean section and she delivered a boy weighing 999 g. The Apgar score was 8 and 9 points at 1 and 5 minutes, respectively. The mother’s heart failure quickly improved after birth and she was discharged at 10 days postoperatively. Fluctuations in circulatory dynamics during pregnancy may sometimes exacerbate heart disease. Therefore, the risks should be fully explained and careful assessment of cardiac function should be performed during pregnancy in patients with severe HOCM.

  5. Association between implantable cardioverter-defibrillator therapy and different lead positions in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Kronborg, Mads Brix; Johansen, Jens Brock; Haarbo, Jens

    2017-01-01

    /mid-ventricular/apical for the LV-LP, and as apical/non-apical for the RV-LP. Appropriate and inappropriate therapies were registered during follow-up via remote monitoring or at device interrogations. Time to event was summarized with Kaplan-Meier plots, and competed risk regression analysis was used to calculate adjusted hazard...... with an apical. We observed no significant association between appropriate therapy and LV-LP in left anterior oblique or right anterior oblique views or inappropriate therapy between any lead positions. Conclusion: An apical RV-LP is associated with an increased risk of appropriate therapy for ventricular...

  6. Self-reported quality of life predicts mortality 7 years post implant in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Andersen, Christina Maar; Veen, Barbara van; Theuns, Dominic A M J

    2018-01-01

    (SD) age=58 (12) consecutively implanted between 2003 and 2010. Patients completed the SF-36. The eight subscales and the physical and mental component summary scores were used as predictors of mortality 7 years post implant. Results: At 7-year follow-up, 33.7% (132/392) of the patients had died...

  7. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  8. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D

    2015-01-01

    -defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  9. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc

    2011-01-01

    . We examined the prevalence and correlates of persistent depression using an intraindividual approach. Consecutive patients who had undergone ICD implantation (n = 386; 79.3% men) completed a set of validated questionnaires, including the Hospital Anxiety and Depression Scale (HADS), at baseline and 3...... months after implantation. Information on ICD therapies was obtained by device interrogation. At 3 months after implantation, 52 (14%) of the 386 patients had persistent depression (HADS cutoff ≥8 before and 3 months after implantation). Heart failure (odds ratio [OR] 2.29; 95% confidence interval [CI] 1.......71), diuretics (OR 2.41; 95% CI 1.26 to 4.61), and psychotropic medication (OR 3.58; 95% CI 1.86 to 6.90) were all significant univariate correlates of persistent depression at 3 months. No effect was found for ICD shock during follow-up (OR 1.59; 95% CI 0.57 to 4.41). In adjusted analysis, New York Heart...

  10. The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Vinther, Michael; Gislason, Gunnar H

    2017-01-01

    -ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3......). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co...

  11. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...... of starting relevant intervention. Methods and analysis: Screen-ICD consists of 3 parts: (1) screening of all hospitalised and outpatient patients at two university hospitals using the Hospital Anxiety and Depression Scale (HADS), scores ≥8 are invited to participate. (2) Assessment of type of anxiety...

  12. Combined etiology of anaphylactic cardiogenic shock: Amiodarone, epinephrine, cardioverter defibrillator, left ventricular assist devices and the Kounis syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas G Kounis

    2015-01-01

    Full Text Available Anaphylactic shock is a life-threatening condition which needs detailed and mediculous clinical assessment and thoughtful treatment. Several causes can join forces in order to degranulate mast cells. Amiodarone which is an iodine-containing highly lipophilic benzofuran can induce allergic reactions and anaphylactic shock in sensitized patients. Epinephrine is a life saving drug, but in sulfite allergic patients it should be given with caution due its metabisulfite preservative. Metals covering cardiac defibrillators and pacemakers can act as antigens attached to serum proteins and induce allergic reactions. In anaphylactic shock, myocardial involvement due to vasospasm-induced coronary blood flow reduction manifesting as Kounis syndrome should be always considered. Clinically, combined treatment targeting the primary cause of anaphylaxis together with protection of cardiac tissue seems to be of paramount importance.

  13. SACRI: A measure of situation awareness for use in the evaluation of nuclear power plant control room systems providing information about the current process state

    International Nuclear Information System (INIS)

    Hogg, D.N.; Follesoe, K.; Volden, F.S.; Torralba, B.

    1994-01-01

    Control room operator support systems and their interface designs have as one goal the enhancement of the operators' situation awareness of the dynamically changing process state. This paper describes a technique for measuring situation awareness within the Human Factors evaluation of control room operator-system interfaces. The technique, referred to as SACRI, has been evaluated in four simulator studies and the main findings from these studies are summarized in this paper. It is concluded that SACRI can be a useful supplement to operator performance measures currently existing for use within control room interface evaluations. (author). 16 refs, 2 figs, 3 tabs

  14. The current limitations of in vitro genotoxicity testing and their relevance to the in vivo situation.

    Science.gov (United States)

    Nesslany, Fabrice

    2017-08-01

    The standard regulatory core battery of genotoxicity tests generally includes 2 or 3 validated tests with at least one in vitro test in bacteria and one in vitro test on cell cultures. However, limitations in in vitro genotoxicity testing may exist at many levels. The knowledge of the underlying mechanisms of genotoxicity is particularly useful to assess the level of relevance for the in vivo situation. In order to avoid wrong conclusions regarding the actual genotoxicity status of any test substance, it appears very important to be aware of the various origins of related bias leading to 'false positives and negatives' by using in vitro methods. Among these, mention may be made on the metabolic activation system, experimental (extreme) conditions, specificities of the test systems implemented, cell type used etc. The knowledge of the actual 'limits' of the in vitro test systems used is clearly an advantage and may contribute to avoid some pitfalls in order to better assess the level of relevance for the in vivo situation. Copyright © 2016. Published by Elsevier Ltd.

  15. Current situation on regulations for mycotoxins. Overview of tolerances and status of standard methods of sampling and analysis.

    Science.gov (United States)

    Van Egmond, H P

    1989-01-01

    A worldwide enquiry was undertaken in 1986-1987 to obtain up-to-date information about mycotoxin legislation in as many countries of the world as possible. Together with some additional data collected in 1981, information is now available about planned, proposed, existing or absence of legislation in 66 countries. Details about tolerances, legal bases, responsible authorities, prescribed methods of sampling and analysis and disposition of commodities containing inadmissible amounts of mycotoxins, are given. The information concerns aflatoxins in foodstuffs, aflatoxin M1 in dairy products, aflatoxins in animal feedstuffs, and other mycotoxins in food- and feedstuffs. In comparison with the situation in 1981, limits and regulations for mycotoxins have been expanded in 1987 with more countries having legislation (proposed or passed) on the subject, more products, and more mycotoxins covered by this legislation. The differences between tolerances in the various countries are sometimes quite large, which makes harmonization of mycotoxin regulations highly desirable.

  16. The limiting current in a one-dimensional situation: Transition from a space charge limited to magnetically limited flow

    International Nuclear Information System (INIS)

    Kumar, Raghwendra; Biswas, Debabrata

    2008-01-01

    For a nonrelativistic electron beam propagating in a cylindrical drift tube, it is shown that the limiting current density does not saturate to the electrostatic one-dimensional (1D) estimate with increasing beam radius. Fully electromagnetic particle-in-cell (PIC) simulation studies show that beyond a critical aspect ratio, the limiting current density is lower than the 1D electrostatic prediction. The lowering in the limiting current density is found to be due to the transition from the space charge limited to magnetically limited flow. An adaptation of Alfven's single particle trajectory method is used to estimate the magnetically limited current as well as the critical radius beyond which the flow is magnetically limited in a drift tube. The predictions are found to be in close agreement with PIC simulations

  17. Disclosure of weather risks of European Utilities : Assessment of the current situation of listed utilities domiciled in Germany, France, Austria, United Kingdom and Switzerland

    OpenAIRE

    Leibfried, Peter; Schuchter, Alexander

    2010-01-01

    With regards to the scientific fact about climate change, weather risk is of increased importance to companies in weather dependent industries. Increasing volatility in temperatures and precipitation as well as unseasonal weather result in increased financial risk to weather dependent companies. This white paper assesses the current situation disclosure of weather dependency and weather risks of European exchange listed companies with the aim to promote transparency in risk reporting to ...

  18. The Current Situation of Hypertension among Rural Minimal Assurance Family Participants in Liaoning (China): A Cross-Sectional Study.

    Science.gov (United States)

    Chen, Yintao; Yu, Shasha; Chen, Shuang; Guo, Xiaofan; Li, Yuan; Li, Zhao; Sun, Yingxian

    2016-12-02

    In China, the prevalence of hypertension is increasing and is showing an epidemic accelerating trend. However, there is a lack of studies reporting the hypertension status of rural residents with minimum living allowances. We performed a cross-sectional study including 11,435 (5285 men and 6150 women) from the general population aged ≥35 years in the Liaoning Province of China from 2012 to 2013, of which 1258 (11.0%) participants came from minimal assurance families. Anthropometric measurements, laboratory examinations and self-reported lifestyle factor information were collected by trained personnel. Multivariate logistic regression was used to detect the association between socioeconomic status (SES) and the risk of hypertension. We found that the prevalence of hypertension was as high as 61.9% in participants from minimal assurance families and the odd ratio for hypertension was 1.32 (95% CI: 1.15-1.52). The awareness, treatment, and control rates among treated hypertensive participants did not increase with higher level of income and education. In the total sample, the lower income levels increased the risk for hypertension, but education didn't show a significant association with hypertension. Thus, there is a severe hypertension situation in the Liaoning rural population of minimal assurance families, which need more attention and prevention and control measures for hypertension.

  19. The long-term supply/demand trend of world energy and the current oil situation in the Asia

    International Nuclear Information System (INIS)

    Okamoto, Hiroyuki

    1996-01-01

    Total world primary energy consumption excluding the FSU increased by 2.9% in 1995, which is somewhat above the 10 year average rate of 2.4%. This reflected strong economic growth in most parts of the world. The increase in demand confirmed the recovery of the link between the economic growth and consumption of primary energy, which broke down in the period of oil crises. Oil demand in the Asian Emerging Market Economies has continued to be very strong. Oil demand has doubled in a decade in this region and is now one sixth of world consumption. Malaysia was the fastest growing oil market in the world in 1995 at 15.5%. In volume terms, S. Korea grew the most in the world by 170,000 b/d, closely followed by China and India. Because of the fast growing oil demand, many energy economists expect a tight supply situation in the Asian oil market in the early 21st Century. However, recent technological developments would be able to supply crude oil appropriate for an increase in oil demand. (author)

  20. Antenatal screening for aneuploidy--surveying the current situation and planning for non-invasive prenatal diagnosis in New Zealand.

    Science.gov (United States)

    Eastwood, Ashley; Webster, Dianne; Taylor, Juliet; Mckay, Richard; McEwen, Alison; Sullivan, Jan; Pope-Couston, Rachel; Stone, Peter

    2016-01-29

    To gauge clinical opinion about the current system and possible changes as well as providing a forum for education about Non-Invasive Prenatal Testing (NIPT). A series of workshops for doctors and midwives, supported by the National Screening Unit of the Ministry of Health and the Royal Australian and New Zealand College of Obstetricians and Gynaecologists, were held in the main centres of New Zealand. Following a brief education session, a structured evaluation of current screening and future possibilities was undertaken by questionnaire. One hundred and eight maternity carers participated in 5 workshops. Over 40% identified barriers to current screening. More than 60% would support NIPT in the first trimester. The majority of carers provided their own counselling support for women. The survey has shown general enthusiasm for the introduction of publically funded NIPT into prenatal screening in New Zealand. Barriers to utilisation of the current system have been identified and enhancements to screening performance with guidelines around conditions to be screened for would be supported.